SIO Argo Site:
Pump Diagnostics







Serial= 4020 - WMO= 2903826


Cycle 31 : GMT 5/ 8/2026 18:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 123.68 49 14.68 386 278 0.28 / 170.17 2 2
2 8 2004.04 58 14.38 2824 2355 2.63 / 172.53 2 3
3 14 1635.20 16 14.42 2392 552 3.18 / 173.08 2 4
4 14 1402.28 16 14.45 2081 481 3.67 / 173.56 2 5
5 14 1076.48 16 14.51 1680 390 4.06 / 173.95 2 6
6 14 764.16 16 14.58 1280 299 4.35 / 174.25 2 7
7 14 463.84 16 14.65 877 206 4.56 / 174.45 2 7
8 14 237.44 16 14.70 558 131 4.69 / 174.58 2 7
9 14 148.88 16 14.72 435 102 4.79 / 174.69 2 7
10 14 69.28 16 14.73 323 76 4.87 / 174.76 2 7
11 14 18.68 16 14.73 251 59 4.93 / 174.82 2 8
12 9 0.08 180 14.73 219 581 5.51 / 175.40 2 55
13 15 -0.16 40 14.72 170 100 5.61 / 175.50 20 247
Average= 5.48
(KJ/cycle)

Cycle 30 : GMT 26/ 7/2026 14:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 49 14.68 353 254 0.25 / 164.48 2 3
2 8 2006.56 58 14.39 2830 2362 2.62 / 166.84 2 4
3 14 1636.48 16 14.43 2395 553 3.17 / 167.39 2 4
4 14 1319.04 16 14.49 1977 458 3.63 / 167.85 2 5
5 14 1144.12 16 14.50 1777 412 4.04 / 168.26 2 5
6 14 807.72 16 14.57 1341 313 4.35 / 168.58 2 6
7 14 536.80 16 14.62 995 233 4.58 / 168.81 2 7
8 14 263.96 16 14.69 618 145 4.73 / 168.95 2 7
9 14 132.00 16 14.71 437 103 4.83 / 169.06 2 7
10 14 58.12 16 14.72 340 80 4.91 / 169.14 2 7
11 14 32.20 16 14.70 306 72 4.98 / 169.21 2 8
12 9 -0.08 180 14.73 220 583 5.57 / 169.79 2 60
13 15 0.04 40 14.72 171 101 5.67 / 169.89 21 247
Average= 5.48
(KJ/cycle)

Cycle 29 : GMT 16/ 7/2026 11:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 49 14.70 363 261 0.26 / 158.90 2 3
2 8 2005.24 58 14.40 2834 2367 2.63 / 161.27 2 4
3 14 1632.32 16 14.44 2390 552 3.18 / 161.82 2 4
4 14 1317.24 16 14.49 1989 461 3.64 / 162.28 2 5
5 14 1186.40 16 14.48 1822 422 4.06 / 162.70 2 5
6 14 771.36 16 14.59 1284 300 4.36 / 163.00 2 7
7 14 552.08 16 14.63 1000 234 4.60 / 163.24 2 7
8 14 233.92 16 14.72 554 130 4.73 / 163.37 2 7
9 14 113.44 16 14.74 385 91 4.82 / 163.46 2 7
10 14 42.48 16 14.75 285 67 4.89 / 163.52 2 7
11 9 0.04 195 14.74 220 632 5.52 / 164.16 2 55
12 15 -0.04 25 14.74 186 69 5.59 / 164.22 17 248
Average= 5.47
(KJ/cycle)

Cycle 28 : GMT 6/ 7/2026 8:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 49 14.71 357 257 0.26 / 153.26 2 3
2 8 2004.12 58 14.40 2832 2365 2.62 / 155.62 2 3
3 14 1630.72 16 14.45 2380 550 3.17 / 156.17 2 4
4 14 1359.28 16 14.48 2044 474 3.65 / 156.65 2 5
5 14 1006.56 16 14.56 1589 370 4.02 / 157.02 2 6
6 14 829.04 16 14.57 1364 318 4.33 / 157.34 2 6
7 14 550.52 16 14.63 993 232 4.57 / 157.57 2 7
8 14 264.20 16 14.71 595 140 4.71 / 157.71 2 7
9 14 134.16 16 14.73 417 98 4.81 / 157.81 2 7
10 14 95.08 16 14.74 360 85 4.89 / 157.89 2 7
11 14 30.76 16 14.74 268 63 4.95 / 157.95 2 8
12 9 0.12 180 14.74 220 584 5.54 / 158.54 2 61
13 15 -0.12 40 14.74 168 99 5.64 / 158.64 18 248
Average= 5.47
(KJ/cycle)

Cycle 27 : GMT 26/ 6/2026 5:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 49 14.72 373 269 0.27 / 147.63 2 3
2 8 2003.44 58 14.40 2833 2366 2.64 / 150.00 2 3
3 14 1591.32 16 14.46 2332 540 3.17 / 150.54 2 5
4 14 1365.96 16 14.47 2043 473 3.65 / 151.01 2 5
5 14 1097.68 16 14.52 1713 398 4.05 / 151.41 2 6
6 14 781.16 16 14.59 1294 302 4.35 / 151.71 2 7
7 14 556.00 16 14.64 1006 236 4.58 / 151.95 2 7
8 14 229.04 16 14.71 547 129 4.71 / 152.08 2 7
9 14 144.88 16 14.73 430 101 4.81 / 152.18 2 7
10 14 71.60 16 14.73 327 77 4.89 / 152.25 2 7
11 14 43.44 16 14.75 287 68 4.96 / 152.32 2 8
12 9 0.00 180 14.75 218 579 5.54 / 152.90 2 53
13 15 -0.20 40 14.74 169 100 5.64 / 153.00 18 247
Average= 5.46
(KJ/cycle)

Cycle 26 : GMT 16/ 6/2026 2:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 49 14.69 361 260 0.26 / 141.93 2 3
2 8 2006.16 58 14.41 2832 2367 2.63 / 144.30 2 4
3 14 1571.52 16 14.46 2306 534 3.16 / 144.83 2 4
4 14 1395.44 16 14.48 2085 483 3.64 / 145.31 2 5
5 14 1077.24 16 14.53 1675 389 4.03 / 145.70 2 6
6 14 897.36 16 14.57 1442 336 4.37 / 146.04 2 7
7 14 615.40 16 14.62 1079 252 4.62 / 146.29 2 7
8 14 249.44 16 14.72 580 137 4.76 / 146.43 2 7
9 14 163.88 16 14.73 456 107 4.87 / 146.53 2 7
10 14 91.48 16 14.75 355 84 4.95 / 146.62 2 7
11 14 60.36 16 14.74 308 73 5.02 / 146.69 2 7
12 9 0.16 180 14.75 217 576 5.60 / 147.27 2 52
13 15 -0.08 40 14.75 166 98 5.70 / 147.36 23 247
Average= 5.46
(KJ/cycle)

Cycle 25 : GMT 6/ 6/2026 11:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 45 14.73 360 239 0.24 / 136.11 2 3
2 11 1035.16 3 14.71 1661 73 0.31 / 136.18 2 3
3 3 1039.08 1 14.75 1669 25 0.34 / 136.20 2 3
4 3 1016.20 1 14.75 1642 24 0.36 / 136.23 2 3
5 8 2003.92 59 14.41 2828 2404 2.77 / 138.63 2 4
6 14 1630.28 16 14.46 2375 549 3.31 / 139.18 2 4
7 14 1312.20 16 14.50 1981 460 3.77 / 139.64 2 5
8 14 1092.28 16 14.53 1695 394 4.17 / 140.04 2 6
9 14 766.64 16 14.60 1276 298 4.47 / 140.33 2 7
10 14 587.20 16 14.64 1046 245 4.71 / 140.58 2 7
11 14 251.52 16 14.73 580 137 4.85 / 140.72 2 7
12 14 164.32 16 14.74 458 108 4.96 / 140.82 2 7
13 14 89.12 16 14.75 368 87 5.04 / 140.91 2 7
14 14 57.80 16 14.74 337 79 5.12 / 140.99 2 8
15 9 0.12 180 14.75 218 579 5.70 / 141.57 2 60
16 15 -0.12 40 14.75 168 99 5.80 / 141.67 16 248
Average= 5.45
(KJ/cycle)

Cycle 24 : GMT 27/ 5/2026 0:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 50 14.73 359 264 0.26 / 130.50 2 3
2 8 2004.08 58 14.41 2832 2367 2.63 / 132.86 2 4
3 14 1681.00 16 14.45 2436 563 3.19 / 133.43 2 4
4 14 1316.20 16 14.51 1975 459 3.65 / 133.89 2 5
5 14 1096.80 16 14.53 1700 395 4.05 / 134.28 2 6
6 14 732.24 16 14.61 1236 289 4.34 / 134.57 2 7
7 14 556.56 16 14.65 996 233 4.57 / 134.80 2 8
8 14 235.44 16 14.72 560 132 4.70 / 134.93 2 7
9 14 152.00 16 14.74 440 104 4.81 / 135.04 2 7
10 14 77.76 16 14.75 336 79 4.89 / 135.12 2 7
11 14 52.00 16 14.76 300 71 4.96 / 135.19 2 8
12 9 -0.08 180 14.76 218 579 5.54 / 135.77 2 54
13 15 0.04 40 14.76 170 100 5.64 / 135.87 18 247
Average= 5.43
(KJ/cycle)

Cycle 23 : GMT 16/ 5/2026 21: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 50 14.72 355 261 0.26 / 124.76 2 3
2 8 2009.04 58 14.41 2841 2374 2.64 / 127.13 2 3
3 14 1681.92 16 14.47 2435 564 3.20 / 127.70 2 4
4 14 1414.88 16 14.50 2110 490 3.69 / 128.19 2 6
5 14 1134.76 16 14.54 1752 408 4.10 / 128.59 2 5
6 14 850.56 16 14.59 1386 324 4.42 / 128.92 2 7
7 14 525.92 16 14.67 981 230 4.65 / 129.15 2 7
8 14 255.72 16 14.73 615 145 4.80 / 129.29 2 7
9 14 128.96 16 14.75 438 103 4.90 / 129.40 2 7
10 14 62.08 16 14.76 350 83 4.98 / 129.48 2 7
11 14 44.96 16 14.76 330 78 5.06 / 129.56 2 7
12 9 0.12 180 14.77 217 577 5.64 / 130.13 2 56
13 15 0.20 40 14.76 169 100 5.74 / 130.23 17 247
Average= 5.43
(KJ/cycle)

Cycle 22 : GMT 6/ 5/2026 18: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 125.68 50 14.72 394 290 0.29 / 119.18 2 3
2 8 2003.64 58 14.42 2831 2368 2.66 / 121.54 2 3
3 14 1569.36 16 14.49 2293 532 3.19 / 122.08 2 5
4 14 1347.76 16 14.50 2025 470 3.66 / 122.55 2 5
5 14 1028.16 16 14.56 1614 376 4.04 / 122.92 2 6
6 14 721.76 16 14.62 1217 285 4.32 / 123.21 2 7
7 14 586.52 16 14.65 1044 245 4.56 / 123.45 2 7
8 14 216.32 16 14.74 535 126 4.69 / 123.58 2 7
9 14 130.24 16 14.75 412 97 4.79 / 123.67 2 8
10 14 52.40 16 14.76 300 71 4.86 / 123.75 2 7
11 14 30.44 16 14.77 269 64 4.92 / 123.81 2 8
12 9 0.04 180 14.75 221 587 5.51 / 124.40 2 230
13 15 -0.20 40 14.75 170 100 5.61 / 124.50 247 247
Average= 5.41
(KJ/cycle)

Cycle 21 : GMT 26/ 4/2026 14:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 122.84 50 14.74 389 287 0.29 / 113.51 2 3
2 8 2006.00 58 14.42 2834 2370 2.66 / 115.88 2 3
3 14 1587.48 16 14.48 2316 537 3.19 / 116.42 2 5
4 14 1407.00 16 14.49 2093 485 3.68 / 116.91 2 5
5 14 1183.16 16 14.53 1814 422 4.10 / 117.33 2 6
6 14 810.92 16 14.61 1334 312 4.41 / 117.64 2 6
7 14 495.52 16 14.68 919 216 4.63 / 117.85 2 8
8 14 191.24 16 14.75 502 118 4.75 / 117.97 2 7
9 14 113.12 16 14.77 389 92 4.84 / 118.07 2 7
10 14 49.04 16 14.78 298 70 4.91 / 118.14 2 7
11 14 28.60 16 14.75 293 69 4.98 / 118.20 2 8
12 9 0.08 180 14.77 219 582 5.56 / 118.79 2 65
13 15 -0.12 40 14.76 169 100 5.66 / 118.89 19 247
Average= 5.40
(KJ/cycle)

Cycle 20 : GMT 16/ 4/2026 11:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 50 14.73 360 265 0.27 / 107.82 2 3
2 8 2008.60 58 14.44 2841 2379 2.64 / 110.20 2 4
3 14 1624.28 16 14.47 2377 550 3.19 / 110.75 2 4
4 14 1403.20 16 14.50 2095 486 3.68 / 111.24 2 5
5 14 1135.04 16 14.55 1746 406 4.09 / 111.64 2 6
6 14 737.40 16 14.63 1240 290 4.38 / 111.93 2 7
7 14 523.60 16 14.68 961 226 4.60 / 112.16 2 7
8 14 244.64 16 14.74 570 134 4.74 / 112.29 2 7
9 14 153.72 16 14.76 445 105 4.84 / 112.40 2 8
10 14 66.72 16 14.76 324 77 4.92 / 112.47 2 7
11 14 19.48 16 14.75 254 60 4.98 / 112.53 2 8
12 9 0.44 180 14.77 222 590 5.57 / 113.12 2 66
13 15 -0.16 40 14.77 174 103 5.67 / 113.23 19 248
Average= 5.39
(KJ/cycle)

Cycle 19 : GMT 6/ 4/2026 8:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 49 14.74 368 266 0.27 / 102.22 2 3
2 8 2008.96 58 14.44 2841 2379 2.65 / 104.60 2 3
3 14 1678.32 16 14.49 2436 565 3.21 / 105.16 2 4
4 14 1318.84 16 14.55 1978 460 3.67 / 105.62 2 5
5 14 1051.56 16 14.59 1644 384 4.05 / 106.01 2 6
6 14 824.84 16 14.62 1355 317 4.37 / 106.32 2 7
7 14 462.72 16 14.71 874 206 4.58 / 106.53 2 7
8 14 236.08 16 14.75 555 131 4.71 / 106.66 2 7
9 14 110.48 16 14.78 385 91 4.80 / 106.75 2 7
10 14 47.16 16 14.80 293 69 4.87 / 106.82 2 7
11 14 27.04 16 14.79 258 61 4.93 / 106.88 2 8
12 9 0.20 180 14.78 216 575 5.50 / 107.46 2 145
13 15 0.08 40 14.78 168 99 5.60 / 107.55 162 248
Average= 5.38
(KJ/cycle)

Cycle 18 : GMT 27/ 3/2026 17:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 50 14.73 399 294 0.29 / 96.56 2 3
2 8 2004.56 58 14.44 2847 2384 2.68 / 98.94 2 3
3 14 1549.36 16 14.52 2291 532 3.21 / 99.47 2 4
4 14 1416.36 16 14.52 2127 494 3.70 / 99.97 2 5
5 14 1107.24 16 14.57 1735 404 4.11 / 100.37 2 6
6 14 778.96 16 14.63 1307 306 4.42 / 100.68 2 7
7 14 604.88 16 14.66 1096 257 4.67 / 100.93 2 7
8 14 220.72 16 14.74 568 134 4.81 / 101.07 2 7
9 14 101.76 16 14.78 400 95 4.90 / 101.16 2 7
10 14 63.68 16 14.75 354 84 4.98 / 101.25 2 7
11 9 0.64 195 14.78 221 637 5.62 / 101.88 2 64
12 15 -0.04 25 14.77 182 67 5.69 / 101.95 17 247
Average= 5.37
(KJ/cycle)

Cycle 17 : GMT 17/ 3/2026 14:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 50 14.76 363 268 0.27 / 90.77 2 3
2 8 2007.60 58 14.44 2837 2376 2.64 / 93.15 2 4
3 14 1585.88 16 14.51 2321 539 3.18 / 93.69 2 5
4 14 1457.36 16 14.51 2169 504 3.69 / 94.19 2 5
5 14 1049.76 16 14.57 1648 384 4.07 / 94.57 2 6
6 14 750.60 16 14.63 1256 294 4.36 / 94.87 2 7
7 14 486.48 16 14.71 906 213 4.58 / 95.08 2 7
8 14 256.48 16 14.75 596 141 4.72 / 95.22 2 7
9 14 129.16 16 14.76 435 103 4.82 / 95.32 2 7
10 14 54.04 16 14.78 336 79 4.90 / 95.40 2 7
11 14 30.84 16 14.77 305 72 4.97 / 95.48 2 8
12 9 0.04 180 14.77 257 683 5.66 / 96.16 2 56
13 15 0.04 40 14.76 175 103 5.76 / 96.26 17 247
Average= 5.35
(KJ/cycle)

Cycle 16 : GMT 7/ 3/2026 12:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 125.92 50 14.76 389 287 0.29 / 85.10 2 3
2 8 2008.44 59 14.44 2834 2414 2.70 / 87.52 2 4
3 14 1624.72 16 14.50 2384 553 3.25 / 88.07 2 5
4 14 1349.00 16 14.53 2018 469 3.72 / 88.54 2 5
5 14 1080.88 16 14.58 1694 395 4.12 / 88.93 2 6
6 14 767.60 16 14.64 1276 299 4.42 / 89.23 2 7
7 14 500.68 16 14.69 927 218 4.64 / 89.45 2 7
8 14 232.64 16 14.76 554 131 4.77 / 89.58 2 7
9 14 148.80 16 14.77 437 103 4.87 / 89.69 2 7
10 14 69.76 16 14.79 324 77 4.95 / 89.76 2 7
11 14 18.76 16 14.79 277 66 5.01 / 89.83 2 7
12 9 0.12 180 14.79 216 575 5.59 / 90.40 2 59
13 15 -0.16 40 14.79 170 101 5.69 / 90.50 18 247
Average= 5.32
(KJ/cycle)

Cycle 15 : GMT 25/ 2/2026 9:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 50 14.76 355 262 0.26 / 79.41 2 3
2 8 2007.40 58 14.45 2829 2371 2.63 / 81.78 2 3
3 14 1629.32 16 14.50 2372 550 3.18 / 82.33 2 5
4 14 1405.00 16 14.52 2097 487 3.67 / 82.82 2 7
5 14 1090.88 16 14.57 1701 397 4.07 / 83.22 2 5
6 14 860.56 16 14.63 1399 327 4.39 / 83.55 2 6
7 14 537.16 16 14.70 969 228 4.62 / 83.77 2 7
8 14 227.92 16 14.77 544 129 4.75 / 83.90 2 7
9 14 147.52 16 14.78 431 102 4.85 / 84.00 2 7
10 14 70.48 16 14.79 322 76 4.93 / 84.08 2 7
11 14 19.96 16 14.79 249 59 4.99 / 84.14 2 7
12 9 0.00 183 14.80 216 585 5.57 / 84.72 2 104
13 15 -0.04 37 14.80 168 92 5.66 / 84.82 103 247
Average= 5.30
(KJ/cycle)

Cycle 14 : GMT 15/ 2/2026 7:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 49 14.77 355 257 0.26 / 73.72 2 3
2 8 2009.72 58 14.46 2832 2375 2.63 / 76.10 2 3
3 14 1630.80 16 14.51 2394 556 3.19 / 76.65 2 4
4 14 1405.56 16 14.53 2101 488 3.68 / 77.14 2 5
5 14 1086.84 16 14.58 1686 393 4.07 / 77.54 2 6
6 14 777.40 16 14.65 1288 302 4.37 / 77.84 2 6
7 14 557.44 16 14.70 1005 236 4.61 / 78.07 2 7
8 14 281.76 16 14.76 621 147 4.75 / 78.22 2 7
9 14 147.12 16 14.79 430 102 4.86 / 78.32 2 7
10 14 64.32 16 14.78 337 80 4.94 / 78.40 2 7
11 14 18.72 16 14.80 283 67 5.00 / 78.47 2 7
12 9 0.84 180 14.81 217 578 5.58 / 79.05 2 60
13 15 0.00 40 14.80 173 102 5.68 / 79.15 19 248
Average= 5.28
(KJ/cycle)

Cycle 13 : GMT 5/ 2/2026 17: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 122.32 45 14.77 381 253 0.25 / 68.13 2 3
2 3 966.76 -1 15.13 0 0 0.00 / 68.13 2 3
3 8 2003.32 58 14.47 2823 2369 2.62 / 70.50 2 4
4 14 1577.72 16 14.53 2301 535 3.16 / 71.04 2 4
5 14 1351.72 16 14.56 2020 471 3.63 / 71.51 2 6
6 14 1083.08 16 14.60 1692 395 4.02 / 71.90 2 5
7 14 771.00 16 14.66 1284 301 4.32 / 72.20 2 7
8 14 502.36 16 14.73 930 219 4.54 / 72.42 2 7
9 14 224.20 16 14.79 544 129 4.67 / 72.55 2 7
10 14 137.76 16 14.80 421 100 4.77 / 72.65 2 7
11 14 58.08 16 14.81 307 73 4.84 / 72.72 2 7
12 14 32.56 16 14.80 265 63 4.91 / 72.79 2 8
13 9 0.76 180 14.80 217 578 5.49 / 73.37 2 84
14 15 0.00 40 14.80 171 101 5.59 / 73.47 21 247
Average= 5.25
(KJ/cycle)

Cycle 12 : GMT 26/ 1/2026 8: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 124.20 49 14.77 378 274 0.27 / 60.85 2 3
2 3 1026.12 1 14.81 1647 24 0.30 / 60.88 2 3
3 3 1019.32 1 14.80 1643 24 0.32 / 60.90 2 3
4 8 2004.64 145 14.34 2820 5864 6.19 / 66.76 2 5
5 14 369.24 16 14.76 745 176 6.36 / 66.94 2 8
6 14 144.88 16 14.81 430 102 6.46 / 67.04 2 7
7 14 105.96 16 14.82 373 88 6.55 / 67.13 2 7
8 14 36.08 16 14.84 275 65 6.62 / 67.20 2 7
9 9 0.00 189 14.83 215 603 7.22 / 67.80 2 71
10 15 -0.12 31 14.83 177 81 7.30 / 67.88 19 248
Average= 5.22
(KJ/cycle)

Cycle 11 : GMT 16/ 1/2026 5:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 45 14.77 352 234 0.23 / 53.44 2 2
2 11 1009.04 3 14.76 1608 71 0.31 / 53.52 2 3
3 3 1033.96 1 14.77 1682 25 0.33 / 53.54 2 3
4 3 1021.40 1 14.80 1655 24 0.35 / 53.57 2 3
5 8 2005.16 145 14.36 2817 5866 6.22 / 59.43 2 4
6 14 382.40 16 14.77 776 183 6.40 / 59.61 2 7
7 14 194.80 16 14.80 520 123 6.53 / 59.74 2 7
8 14 107.48 16 14.82 375 89 6.62 / 59.83 2 7
9 14 36.40 16 14.84 275 65 6.68 / 59.89 2 7
10 9 0.00 187 14.84 216 599 7.28 / 60.49 2 54
11 15 0.12 33 14.83 179 88 7.37 / 60.58 22 247
Average= 5.05
(KJ/cycle)

Cycle 10 : GMT 6/ 1/2026 3:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 124.60 49 14.77 396 287 0.29 / 46.17 2 3
2 8 2004.12 145 14.33 2829 5878 6.16 / 52.05 2 5
3 14 402.04 16 14.74 809 191 6.36 / 52.24 2 7
4 14 169.12 16 14.79 493 117 6.47 / 52.36 2 7
5 14 85.48 16 14.80 379 90 6.56 / 52.45 2 7
6 14 23.84 16 14.81 294 70 6.63 / 52.52 2 7
7 9 0.08 187 14.81 219 607 7.24 / 53.12 2 53
8 15 -0.04 33 14.80 179 87 7.33 / 53.21 16 248
Average= 4.84
(KJ/cycle)

Cycle 9 : GMT 5/ 1/2026 8: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 48 14.76 360 255 0.26 / 39.44 2 3
2 8 1820.04 146 14.40 2585 5435 5.69 / 44.88 2 4
3 14 229.88 16 14.78 548 130 5.82 / 45.01 2 7
4 14 144.64 16 14.81 427 101 5.92 / 45.11 2 7
5 14 61.28 16 14.82 310 74 5.99 / 45.18 2 6
6 9 1.00 200 14.82 219 649 6.64 / 45.83 2 61
7 15 0.00 20 14.81 188 56 6.70 / 45.89 20 248
Average= 4.59
(KJ/cycle)

Cycle 8 : GMT 4/ 1/2026 13:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 122.80 48 14.79 390 277 0.28 / 32.74 2 3
2 8 1811.72 145 14.41 2586 5403 5.68 / 38.14 2 5
3 14 262.60 16 14.78 615 145 5.83 / 38.29 2 7
4 14 175.40 16 14.79 503 119 5.94 / 38.41 2 7
5 14 46.48 16 14.82 325 77 6.02 / 38.49 2 7
6 9 0.08 200 14.83 217 644 6.67 / 39.13 2 52
7 15 -0.04 20 14.81 190 56 6.72 / 39.19 19 248
Average= 4.35
(KJ/cycle)

Cycle 7 : GMT 3/ 1/2026 19:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 125.24 48 14.84 393 280 0.28 / 26.82 2 3
2 8 1519.84 145 14.53 2220 4677 4.96 / 31.50 2 6
3 14 185.88 16 14.83 482 114 5.07 / 31.61 2 7
4 14 102.52 16 14.84 370 88 5.16 / 31.70 2 7
5 14 37.24 16 14.85 277 66 5.23 / 31.77 2 6
6 9 0.16 195 14.85 218 631 5.86 / 32.40 2 77
7 15 -0.04 25 14.84 181 67 5.92 / 32.46 18 248
Average= 4.06
(KJ/cycle)

Cycle 6 : GMT 3/ 1/2026 2:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 126.56 48 14.84 396 282 0.28 / 22.44 2 3
2 8 1011.96 145 14.74 1586 3390 3.67 / 25.83 2 8
3 9 0.00 187 14.89 224 624 4.30 / 26.45 2 76
4 15 -0.08 33 14.89 176 86 4.38 / 26.54 124 248
Average= 3.79
(KJ/cycle)

Cycle 5 : GMT 2/ 1/2026 11:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.52 48 14.84 384 274 0.27 / 18.10 2 2
2 8 1013.08 145 14.74 1568 3351 3.62 / 21.45 2 8
3 9 0.16 187 14.89 223 621 4.25 / 22.07 2 204
4 15 -0.04 33 14.88 176 86 4.33 / 22.16 245 248
Average= 3.69
(KJ/cycle)

Cycle 4 : GMT 1/ 1/2026 21: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 124.12 48 14.79 394 280 0.28 / 13.77 2 2
2 8 1016.68 145 14.75 1569 3356 3.64 / 17.12 2 8
3 9 0.60 187 14.89 222 618 4.25 / 17.74 2 51
4 15 -0.16 33 14.88 178 87 4.34 / 17.83 20 248
Average= 3.57
(KJ/cycle)

Cycle 3 : GMT 1/ 1/2026 6: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 122.16 48 14.83 392 279 0.28 / 9.41 2 2
2 8 1012.56 146 14.75 1563 3366 3.64 / 12.78 2 9
3 9 0.60 187 14.89 223 621 4.27 / 13.40 2 79
4 15 -0.20 33 14.89 178 87 4.35 / 13.49 152 248
Average= 3.37
(KJ/cycle)

Cycle 2 : GMT 31/12/2025 15:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.64 45 14.80 379 252 0.25 / 5.00 2 3
2 11 1038.84 2 14.81 1674 50 0.30 / 5.05 2 3
3 3 1024.96 1 14.82 1669 25 0.33 / 5.07 2 2
4 3 1018.28 1 14.84 1626 24 0.35 / 5.10 2 2
5 8 1004.56 145 14.77 1551 3322 3.67 / 8.42 2 8
6 9 -0.04 187 14.90 224 624 4.30 / 9.04 2 59
7 15 -0.16 33 14.89 180 88 4.39 / 9.13 23 248
Average= 3.04
(KJ/cycle)

Cycle 1 : GMT 31/12/2025 0:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.64 65 15.00 369 360 0.36 / 1.98 3 3
2 11 551.24 4 14.93 963 58 0.42 / 2.04 2 3
3 3 585.48 2 14.94 1016 30 0.45 / 2.07 2 3
4 3 572.92 2 14.94 1005 30 0.48 / 2.10 2 3
5 8 552.72 145 14.84 934 2010 2.49 / 4.11 2 8
6 9 -0.12 159 14.87 209 494 2.98 / 4.60 2 179
7 15 -0.20 61 14.86 159 144 3.13 / 4.75 227 247
Average= 2.37
(KJ/cycle)

Cycle 0 : GMT 30/12/2025 21:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 78.88 65 15.17 317 313 0.31 / 0.31 3 3
2 8 110.40 145 15.14 338 742 1.05 / 1.05 3 7
3 9 0.12 155 15.12 185 434 1.49 / 1.49 3 112
4 15 0.12 65 15.11 136 134 1.62 / 1.62 162 247
Average= 1.62
(KJ/cycle)