SIO Argo Site:
Pump Diagnostics Page   



Serial= 8754 WMO= 7900688

Return

←PreviousNext→

Cycle 28 GMT 13/ 9/2019 4:23:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.68 5 15.20 663 50 0.05 / 105.73 2 4
2 3 852.84 -5 15.53 0 0 0.00 / 105.73 2 4
3 7 2002.56 30 14.90 2956 1321 1.37 / 107.05 2 8
4 13 1588.08 28 14.90 2453 1023 2.40 / 108.08 2 4
5 13 522.20 28 15.11 1106 468 2.86 / 108.55 2 8
6 8 -0.20 175 15.20 355 944 3.81 / 109.49 2 13
7 14 -0.20 20 15.17 378 115 3.92 / 109.60 2 13
Average= 3.78 (KJ/cycle)

Cycle 27

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.48 23 15.18 640 223 0.22 / 102.88 2 5
2 3 253.88 -24 15.53 0 0 0.00 / 102.88 2 5
3 3 884.52 -4 15.54 0 0 0.00 / 102.88 2 5
4 7 2001.64 30 14.90 2941 1315 1.54 / 104.19 2 6
5 13 1443.08 28 14.94 2269 949 2.49 / 105.14 2 4
6 13 656.84 28 15.08 1279 540 3.03 / 105.68 2 7
Average= 3.77 (KJ/cycle)

Cycle 26

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.08 23 15.12 620 216 0.22 / 99.79 2 4
2 7 2002.92 30 14.92 2942 1317 1.53 / 101.10 2 3
3 13 1463.80 28 14.94 2288 957 2.49 / 102.06 2 3
4 13 699.32 28 15.07 1325 559 3.05 / 102.62 2 5
5 13 52.48 5 15.24 484 37 3.09 / 102.66 2 6
Average= 3.80 (KJ/cycle)

Cycle 25 GMT 14/ 8/2019 10:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 162.20 23 15.13 624 217 0.22 / 95.68 2 4
2 10 1000.84 2 15.10 1775 54 0.27 / 95.73 2 3
3 3 943.96 -2 15.51 0 0 0.05 / 95.73 2 3
4 7 2002.40 30 14.92 2937 1315 1.59 / 97.05 2 5
5 13 1584.40 28 14.92 2431 1016 2.60 / 98.06 2 4
6 13 629.60 28 15.10 1231 520 3.12 / 98.58 2 5
7 8 0.16 175 15.21 370 985 4.11 / 99.57 2 13
Average= 3.83 (KJ/cycle)

Cycle 24 GMT 4/ 8/2019 12:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.12 22 15.13 621 207 0.21 / 91.70 2 4
2 3 1037.00 1 15.19 1851 28 0.23 / 91.73 2 3
3 7 2002.56 30 14.93 2942 1318 1.55 / 93.05 2 6
4 13 1464.12 28 14.95 2285 957 2.51 / 94.01 2 4
5 13 550.64 28 15.12 1126 477 2.99 / 94.48 2 6
6 8 0.00 175 15.21 368 980 3.97 / 95.46 2 18
Average= 3.82 (KJ/cycle)

Cycle 23 GMT 25/ 7/2019 14:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 150.20 23 15.13 613 213 0.21 / 87.64 2 5
2 3 968.00 -1 15.52 0 0 0.00 / 87.64 2 5
3 7 2004.56 31 14.93 2949 1365 1.58 / 89.01 2 9
4 13 1447.68 28 14.96 2268 950 2.53 / 89.96 2 5
5 13 677.84 28 15.09 1289 545 3.07 / 90.50 2 5
6 8 0.04 175 15.21 374 995 4.07 / 91.50 2 14
Average= 3.81 (KJ/cycle)

Cycle 22 GMT 15/ 7/2019 16: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.40 23 15.12 630 219 0.22 / 83.61 2 4
2 3 1020.32 1 15.22 1834 28 0.25 / 83.63 2 2
3 7 2006.04 30 14.94 2953 1324 1.57 / 84.96 2 4
4 13 1573.28 28 14.94 2424 1014 2.58 / 85.97 2 6
5 13 522.44 28 15.14 1090 462 3.05 / 86.43 2 6
6 8 0.44 175 15.22 374 996 4.04 / 87.43 2 18
Average= 3.80 (KJ/cycle)

Cycle 21 GMT 5/ 7/2019 17:33:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.00 23 15.14 615 214 0.21 / 79.32 2 4
2 7 2001.68 30 14.93 2942 1318 1.53 / 80.64 2 4
3 13 1565.12 28 14.94 2408 1007 2.54 / 81.65 2 4
4 13 777.00 28 15.07 1424 601 3.14 / 82.25 2 5
5 13 45.56 5 15.27 470 36 3.18 / 82.28 2 7
6 8 0.28 175 15.22 372 991 4.17 / 83.27 2 15
7 14 0.28 20 15.19 377 115 4.28 / 83.39 2 14
Average= 3.79 (KJ/cycle)

Cycle 20 GMT 25/ 6/2019 19:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 152.32 24 15.15 609 221 0.22 / 75.21 2 4
2 3 957.52 -1 15.53 0 0 0.00 / 75.21 2 4
3 7 2002.24 30 14.95 2946 1321 1.54 / 76.54 2 3
4 13 1573.88 28 14.95 2429 1017 2.56 / 77.55 2 3
5 13 621.20 28 15.12 1222 517 3.08 / 78.07 2 6
6 13 59.72 5 15.27 494 38 3.11 / 78.11 2 6
7 8 0.04 175 15.22 375 999 4.11 / 79.11 2 15
Average= 3.77 (KJ/cycle)

Cycle 19 GMT 15/ 6/2019 21:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.16 24 15.15 626 228 0.23 / 71.14 2 4
2 7 2004.92 31 14.94 2939 1361 1.59 / 72.50 2 4
3 13 1450.60 28 14.97 2269 951 2.54 / 73.45 2 4
4 13 667.32 28 15.11 1278 541 3.08 / 74.00 2 6
5 8 0.48 175 15.23 374 997 4.08 / 74.99 2 15
Average= 3.75 (KJ/cycle)

Cycle 18 GMT 5/ 6/2019 23: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 164.28 24 15.15 626 228 0.23 / 67.02 2 4
2 7 2003.12 31 14.95 2941 1363 1.59 / 68.39 2 3
3 13 1575.16 28 14.95 2423 1014 2.60 / 69.40 2 5
4 13 625.48 28 15.12 1225 519 3.12 / 69.92 2 6
5 8 0.00 175 15.23 374 997 4.12 / 70.92 2 16
Average= 3.73 (KJ/cycle)

Cycle 17 GMT 27/ 5/2019 0:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 165.20 23 15.15 630 220 0.22 / 62.96 2 4
2 3 1016.20 1 15.25 1841 28 0.25 / 62.99 2 2
3 7 2003.24 30 14.95 2941 1319 1.57 / 64.31 2 4
4 13 1442.04 28 14.98 2253 945 2.51 / 65.26 2 4
5 13 669.24 28 15.11 1279 541 3.05 / 65.80 2 6
6 8 0.32 175 15.23 374 997 4.05 / 66.79 2 13
Average= 3.71 (KJ/cycle)

Cycle 16 GMT 17/ 5/2019 2:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.88 23 15.17 609 212 0.21 / 59.15 2 4
2 7 2002.40 30 14.96 2953 1325 1.54 / 60.48 2 3
3 13 1452.60 16 15.03 2294 552 2.09 / 61.03 2 3
4 13 1031.52 16 15.07 1762 425 2.51 / 61.45 2 4
5 13 440.04 16 15.19 997 242 2.76 / 61.69 2 5
6 13 80.60 6 15.28 520 48 2.80 / 61.74 2 6
7 8 0.08 175 15.24 376 1003 3.81 / 62.75 2 19
Average= 3.69 (KJ/cycle)

Cycle 15 GMT 7/ 5/2019 3:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.40 24 15.16 600 218 0.22 / 55.25 2 3
2 7 2003.44 30 14.98 2949 1325 1.54 / 56.58 2 4
3 13 1587.36 16 15.01 2459 591 2.13 / 57.17 2 5
4 13 1145.00 16 15.06 1900 458 2.59 / 57.63 2 4
5 13 438.32 16 15.20 987 240 2.83 / 57.87 2 5
6 13 78.40 6 15.29 510 47 2.88 / 57.92 2 6
7 13 46.00 5 15.29 471 36 2.91 / 57.95 2 6
8 8 0.28 175 15.24 370 987 3.90 / 58.94 2 12
Average= 3.68 (KJ/cycle)

Cycle 14 GMT 27/ 4/2019 5: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.48 24 15.17 612 223 0.22 / 51.25 2 3
2 7 2003.60 30 14.98 2951 1326 1.55 / 52.57 2 4
3 13 1445.76 16 15.04 2284 550 2.10 / 53.12 2 3
4 13 1030.68 16 15.09 1759 425 2.52 / 53.55 2 5
5 13 448.24 16 15.20 1003 244 2.77 / 53.79 2 7
6 13 89.32 6 15.29 526 48 2.82 / 53.84 2 6
7 13 20.00 16 15.29 422 103 2.92 / 53.94 2 7
8 8 -0.12 175 15.24 368 981 3.90 / 54.93 2 20
9 14 -0.12 20 15.22 363 110 4.01 / 55.04 2 12
Average= 3.67 (KJ/cycle)

Cycle 13 GMT 17/ 4/2019 6:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 163.32 24 15.17 626 228 0.23 / 47.38 2 3
2 7 2002.32 30 14.98 2950 1326 1.55 / 48.71 2 3
3 13 1577.56 16 15.02 2442 587 2.14 / 49.30 2 3
4 13 992.08 16 15.10 1707 412 2.55 / 49.71 2 5
5 13 431.44 16 15.21 978 238 2.79 / 49.95 2 5
6 13 78.64 6 15.29 513 47 2.84 / 49.99 2 6
7 13 55.56 5 15.30 480 37 2.87 / 50.03 2 6
8 8 0.16 175 15.25 373 995 3.87 / 51.03 2 10
Average= 3.64 (KJ/cycle)

Cycle 12 GMT 7/ 4/2019 8:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.96 24 15.17 618 225 0.23 / 43.52 2 4
2 7 2000.96 30 14.99 2943 1323 1.55 / 44.85 2 3
3 13 1458.48 16 15.04 2307 555 2.10 / 45.40 2 4
4 13 1034.04 16 15.09 1772 428 2.53 / 45.83 2 4
5 13 449.96 16 15.20 1006 245 2.78 / 46.07 2 5
6 13 82.68 6 15.30 516 47 2.82 / 46.12 2 5
7 13 47.32 5 15.30 476 36 2.86 / 46.16 2 6
8 8 0.20 175 15.25 374 998 3.86 / 47.16 2 11
Average= 3.63 (KJ/cycle)

Cycle 11 GMT 28/ 3/2019 9:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 167.48 24 15.18 626 228 0.23 / 39.72 2 4
2 3 1020.88 1 15.25 1828 28 0.26 / 39.74 2 2
3 7 2001.80 30 14.98 2944 1323 1.58 / 41.07 2 3
4 13 1312.40 16 15.07 2117 510 2.09 / 41.58 2 3
5 13 1046.52 16 15.09 1775 429 2.52 / 42.01 2 4
6 13 477.52 16 15.20 1041 253 2.77 / 42.26 2 7
7 13 89.24 6 15.29 529 49 2.82 / 42.31 2 6
8 8 0.28 175 15.25 371 990 3.81 / 43.30 2 13
Average= 3.61 (KJ/cycle)

Cycle 10 GMT 18/ 3/2019 11:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.28 24 15.19 610 222 0.22 / 35.86 2 3
2 7 2001.32 30 14.98 2948 1325 1.55 / 37.18 2 4
3 13 1567.56 18 15.01 2422 654 2.20 / 37.84 2 3
4 13 968.12 18 15.10 1677 456 2.66 / 38.29 2 4
5 13 225.80 10 15.27 712 109 2.77 / 38.40 2 6
6 13 80.56 6 15.30 516 47 2.81 / 38.45 2 6
7 13 60.00 5 15.30 490 37 2.85 / 38.49 2 7
8 8 0.08 175 15.25 375 1001 3.85 / 39.49 2 15
Average= 3.59 (KJ/cycle)

Cycle 9 GMT 8/ 3/2019 12:34: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.72 23 15.18 602 210 0.21 / 32.04 2 3
2 3 1020.60 1 15.27 1829 28 0.24 / 32.06 2 3
3 7 2000.72 30 14.98 2948 1325 1.56 / 33.39 2 3
4 13 1452.64 16 15.05 2293 552 2.12 / 33.94 2 3
5 13 1021.96 16 15.10 1750 423 2.54 / 34.36 2 5
6 13 428.80 16 15.21 980 238 2.78 / 34.60 2 5
7 13 55.20 16 15.30 472 116 2.89 / 34.72 2 6
8 8 0.20 165 15.26 365 919 3.81 / 35.64 2 14
Average= 3.56 (KJ/cycle)

Cycle 8 GMT 26/ 2/2019 13:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.12 23 15.19 614 215 0.21 / 27.96 2 3
2 3 1025.16 1 15.26 1833 28 0.24 / 27.98 2 2
3 7 2002.60 30 15.00 2948 1327 1.57 / 29.31 2 5
4 13 1575.36 17 15.03 2443 624 2.19 / 29.94 2 4
5 13 989.72 17 15.11 1707 438 2.63 / 30.37 2 6
6 13 391.92 17 15.23 932 241 2.87 / 30.62 2 6
7 13 46.76 17 15.31 458 119 2.99 / 30.73 2 6
8 8 0.48 165 15.26 367 924 3.92 / 31.66 2 16
9 14 0.48 30 15.24 365 167 4.08 / 31.83 2 22
Average= 3.54 (KJ/cycle)

Cycle 7 GMT 16/ 2/2019 14:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 154.56 23 15.18 617 215 0.22 / 24.13 2 3
2 7 2001.56 30 14.99 2957 1330 1.55 / 25.46 2 7
3 13 1581.72 17 15.03 2447 625 2.17 / 26.08 2 3
4 13 864.88 17 15.13 1552 399 2.57 / 26.48 2 5
5 13 317.08 17 15.24 832 216 2.79 / 26.70 2 7
6 13 16.20 17 15.31 413 107 2.89 / 26.80 2 7
7 8 0.00 165 15.26 373 939 3.83 / 27.74 2 16
Average= 3.47 (KJ/cycle)

Cycle 6 GMT 6/ 2/2019 16: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 161.24 22 15.18 632 211 0.21 / 20.10 2 4
2 3 1023.92 1 15.26 1862 28 0.24 / 20.13 2 3
3 7 1996.84 38 14.94 2940 1669 1.91 / 21.80 2 8
4 13 1265.04 17 15.07 2062 528 2.44 / 22.33 2 4
5 13 673.56 17 15.16 1302 336 2.77 / 22.66 2 5
6 13 113.04 7 15.30 570 61 2.83 / 22.72 2 6
7 13 69.00 6 15.31 512 47 2.88 / 22.77 2 6
8 8 -0.04 165 15.27 383 965 3.85 / 23.74 2 20
9 14 -0.04 30 15.24 382 175 4.02 / 23.91 2 18
Average= 3.42 (KJ/cycle)

Cycle 5 GMT 27/ 1/2019 15:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 160.96 29 15.17 632 278 0.28 / 16.29 2 4
2 3 716.44 -9 15.57 0 0 0.00 / 16.29 2 4
3 3 981.72 -1 15.59 0 0 0.00 / 16.29 2 4
4 7 1985.80 38 14.95 2921 1659 1.94 / 17.95 2 11
5 13 1244.52 17 15.08 2037 522 2.46 / 18.47 2 4
6 13 684.04 17 15.17 1320 340 2.80 / 18.81 2 6
7 13 118.20 7 15.30 574 61 2.86 / 18.87 2 6
8 13 71.24 6 15.31 512 47 2.91 / 18.92 2 6
9 8 0.08 165 15.27 386 973 3.88 / 19.89 2 14
Average= 3.32 (KJ/cycle)

Cycle 4 GMT 17/ 1/2019 14:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 158.32 21 15.18 628 200 0.20 / 12.78 2 4
2 3 1030.00 1 15.24 1860 28 0.23 / 12.81 2 3
3 7 1524.92 38 15.05 2363 1351 1.58 / 14.16 2 4
4 13 1118.44 17 15.11 1874 481 2.06 / 14.64 2 5
5 13 530.28 17 15.20 1123 290 2.35 / 14.93 2 7
6 13 101.64 7 15.31 558 60 2.41 / 14.99 2 6
7 13 42.80 5 15.32 481 37 2.45 / 15.03 2 7
8 8 0.08 165 15.26 389 979 3.43 / 16.01 2 15
Average= 3.20 (KJ/cycle)

Cycle 3 GMT 16/ 1/2019 15:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 156.48 17 15.20 633 164 0.16 / 9.26 2 3
2 10 1030.80 4 15.11 1848 112 0.28 / 9.37 2 3
3 3 1033.20 1 15.24 1864 28 0.30 / 9.40 2 3
4 7 1518.20 38 15.05 2352 1345 1.65 / 10.75 2 4
5 13 1114.60 17 15.11 1862 478 2.13 / 11.23 2 5
6 13 543.76 17 15.20 1136 294 2.42 / 11.52 2 5
7 13 66.96 6 15.32 511 47 2.47 / 11.57 2 6
8 13 51.48 5 15.31 492 38 2.51 / 11.60 2 7
9 8 0.20 165 15.26 388 977 3.48 / 12.58 2 15
Average= 3.15 (KJ/cycle)

Cycle 2 GMT 15/ 1/2019 16:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 32 15.25 552 269 0.27 / 5.43 2 4
2 3 611.44 -7 15.60 0 0 0.00 / 5.43 2 4
3 3 818.72 -3 15.62 0 0 0.00 / 5.43 2 4
4 7 1517.68 74 14.98 2335 2588 2.86 / 8.02 2 4
5 13 102.12 7 15.32 552 59 2.92 / 8.08 2 6
6 13 48.24 5 15.33 486 37 2.95 / 8.12 2 7
7 8 0.24 165 15.28 389 981 3.93 / 9.10 2 14
Average= 3.03 (KJ/cycle)

Cycle 1 GMT 14/ 1/2019 18:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 27 15.44 500 208 0.21 / 2.30 2 2
2 3 794.52 -4 15.64 0 0 0.00 / 2.30 2 2
3 3 918.48 -2 15.65 0 0 0.00 / 2.30 2 2
4 7 981.32 74 15.15 1669 1871 2.08 / 4.17 2 5
5 8 0.16 165 15.34 391 990 3.07 / 5.16 2 13
Average= 2.58 (KJ/cycle)

Cycle 0 GMT 14/ 1/2019 8: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 157.80 27 15.61 559 236 0.24 / 0.24 2 2
2 7 171.08 74 15.56 557 641 0.88 / 0.88 2 3
3 8 -0.04 240 15.52 327 1218 2.09 / 2.09 2 18
Average= 2.09 (KJ/cycle)