SIO Argo Site:
Pump Diagnostics Page   



Serial= 8710 WMO= 5905725

Return

←PreviousNext→

Cycle 207 GMT 15/ 4/2024 2:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 36 14.91 541 290 0.29 / 811.90 2 2
2 12 1175.36 4 15.17 1948 118 0.41 / 812.02 2 2
3 7 2003.16 34 14.77 2857 1435 1.84 / 813.46 2 2
4 13 1507.12 18 14.79 2316 617 2.46 / 814.07 2 4
5 13 1020.72 18 14.81 1730 461 2.92 / 814.54 2 5
6 13 512.96 18 14.90 1069 287 3.21 / 814.82 2 5
7 8 0.00 165 14.96 371 916 4.12 / 815.74 2 10
Average= 3.92
(KJ/cycle)

Cycle 206 GMT 5/ 4/2024 4:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 36 14.91 515 276 0.28 / 807.75 2 2
2 12 1171.16 4 15.17 1954 119 0.40 / 807.87 2 3
3 7 2007.24 34 14.77 2865 1439 1.83 / 809.31 3 3
4 13 1525.24 18 14.78 2339 622 2.46 / 809.93 2 4
5 13 1041.12 18 14.81 1750 467 2.92 / 810.40 2 7
6 13 529.36 18 14.89 1078 289 3.21 / 810.69 2 6
7 8 0.40 165 14.96 375 926 4.14 / 811.61 2 11
Average= 3.92
(KJ/cycle)

Cycle 205 GMT 26/ 3/2024 6: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 36 14.92 526 283 0.28 / 803.50 2 2
2 12 1184.12 4 15.18 1966 119 0.40 / 803.61 2 3
3 7 2009.12 34 14.77 2873 1443 1.84 / 805.06 3 2
4 13 1512.56 18 14.79 2327 619 2.46 / 805.68 2 3
5 13 1031.52 18 14.82 1741 464 2.93 / 806.14 2 4
6 13 365.92 18 14.93 877 236 3.16 / 806.38 2 4
7 13 18.88 18 15.01 388 105 3.27 / 806.48 2 3
8 8 -0.16 165 14.97 350 865 4.13 / 807.35 2 12
9 14 -0.16 25 14.94 350 131 4.26 / 807.48 3 12
Average= 3.92
(KJ/cycle)

Cycle 204 GMT 16/ 3/2024 7:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 36 14.91 525 282 0.28 / 799.29 2 2
2 12 1177.64 4 15.17 1967 119 0.40 / 799.41 2 4
3 7 2004.76 35 14.76 2857 1476 1.88 / 800.89 4 3
4 13 1509.68 18 14.79 2319 617 2.49 / 801.50 2 4
5 13 1001.92 18 14.82 1694 452 2.95 / 801.96 2 4
6 13 363.12 18 14.94 861 232 3.18 / 802.19 2 4
7 13 38.48 18 15.01 420 113 3.29 / 802.30 2 3
8 8 -0.08 165 14.97 369 911 4.20 / 803.21 2 14
Average= 3.92
(KJ/cycle)

Cycle 203 GMT 6/ 3/2024 9:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 36 14.91 513 275 0.28 / 795.10 2 2
2 12 1167.80 4 15.18 1951 118 0.39 / 795.22 2 3
3 7 2004.72 34 14.78 2865 1440 1.83 / 796.66 3 2
4 13 1519.32 18 14.79 2340 623 2.46 / 797.28 2 3
5 13 1172.92 18 14.79 1916 510 2.97 / 797.79 2 7
6 13 486.36 18 14.91 1027 276 3.24 / 798.07 2 5
7 8 0.20 165 14.97 381 941 4.18 / 799.01 2 10
Average= 3.92
(KJ/cycle)

Cycle 202 GMT 25/ 2/2024 11:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 36 14.93 513 276 0.28 / 790.87 2 2
2 12 1178.76 4 15.18 1973 120 0.40 / 790.99 2 3
3 7 2008.76 34 14.78 2873 1444 1.84 / 792.44 3 4
4 13 1519.36 18 14.80 2336 622 2.46 / 793.06 2 4
5 13 1027.92 18 14.82 1736 463 2.92 / 793.52 2 5
6 13 534.12 18 14.89 1096 294 3.22 / 793.82 2 5
7 13 32.28 18 15.01 412 111 3.33 / 793.93 2 3
8 8 -0.20 165 14.97 364 899 4.23 / 794.83 2 12
Average= 3.92
(KJ/cycle)

Cycle 201 GMT 15/ 2/2024 13:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 36 14.92 518 278 0.28 / 786.68 2 2
2 12 1358.84 4 15.13 2191 133 0.41 / 786.82 2 3
3 7 2003.64 34 14.78 2853 1434 1.84 / 788.25 3 4
4 13 1509.16 18 14.80 2303 614 2.46 / 788.86 2 3
5 13 1017.12 18 14.82 1721 459 2.92 / 789.32 2 5
6 13 513.28 18 14.90 1064 285 3.20 / 789.61 2 4
7 13 28.16 18 15.02 398 108 3.31 / 789.72 2 3
8 8 0.16 165 14.98 357 882 4.19 / 790.60 2 9
Average= 3.91
(KJ/cycle)

Cycle 200 GMT 5/ 2/2024 15:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 36 14.92 503 270 0.27 / 782.39 2 2
2 12 1175.48 4 15.18 1966 119 0.39 / 782.51 2 3
3 7 2002.12 34 14.78 2857 1436 1.83 / 783.94 3 3
4 13 1500.60 18 14.80 2303 614 2.44 / 784.55 2 4
5 13 1157.80 18 14.81 1891 504 2.94 / 785.06 2 8
6 13 626.20 18 14.88 1226 328 3.27 / 785.39 2 4
7 13 23.48 18 15.01 405 109 3.38 / 785.50 2 3
8 8 0.24 165 14.97 368 909 4.29 / 786.41 2 12
Average= 3.91
(KJ/cycle)

Cycle 199 GMT 26/ 1/2024 17:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 36 14.92 507 272 0.27 / 778.04 2 2
2 12 1153.00 4 15.19 1946 118 0.39 / 778.15 2 3
3 7 2007.40 34 14.78 2861 1438 1.83 / 779.59 3 3
4 13 1522.32 18 14.79 2330 620 2.45 / 780.21 2 4
5 13 1177.16 18 14.79 1915 510 2.96 / 780.72 2 4
6 13 458.72 18 14.92 990 266 3.22 / 780.99 2 5
7 13 24.36 18 15.02 395 107 3.33 / 781.09 2 3
8 8 -0.24 165 14.97 360 889 4.22 / 781.98 2 13
9 14 -0.24 25 14.95 353 132 4.35 / 782.12 2 14
Average= 3.91
(KJ/cycle)

Cycle 198 GMT 16/ 1/2024 19:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 36 14.90 526 282 0.28 / 773.83 2 2
2 12 1172.72 4 15.18 1965 119 0.40 / 773.95 2 3
3 7 2003.40 34 14.78 2874 1444 1.85 / 775.39 3 3
4 13 1514.52 18 14.80 2320 618 2.46 / 776.01 2 2
5 13 1040.36 18 14.81 1744 465 2.93 / 776.47 2 5
6 13 532.28 18 14.89 1084 291 3.22 / 776.76 2 5
7 13 36.12 18 15.00 415 112 3.33 / 776.88 2 3
8 8 0.16 165 14.97 359 887 4.22 / 777.76 2 13
Average= 3.91
(KJ/cycle)

Cycle 197 GMT 6/ 1/2024 21:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 36 14.93 503 270 0.27 / 769.60 2 2
2 12 1177.48 4 15.19 1955 119 0.39 / 769.72 2 3
3 7 2006.56 34 14.78 2862 1438 1.83 / 771.16 3 3
4 13 1514.96 18 14.80 2313 616 2.44 / 771.77 2 2
5 13 1059.32 18 14.81 1766 471 2.91 / 772.24 2 4
6 13 542.36 18 14.90 1088 292 3.21 / 772.54 2 4
7 13 29.28 18 15.01 402 109 3.31 / 772.64 2 3
8 8 0.12 165 14.96 365 901 4.22 / 773.55 2 14
Average= 3.91
(KJ/cycle)

Cycle 196 GMT 27/12/2023 23:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 36 14.92 521 280 0.28 / 765.47 2 2
2 12 1173.48 4 15.19 1948 118 0.40 / 765.59 2 2
3 7 2003.28 34 14.78 2848 1431 1.83 / 767.02 2 3
4 13 1667.40 18 14.78 2487 662 2.49 / 767.68 2 3
5 13 1142.44 18 14.81 1869 498 2.99 / 768.18 2 5
6 13 489.16 18 14.91 1018 273 3.26 / 768.45 2 5
7 8 0.16 165 14.98 355 877 4.14 / 769.33 2 11
Average= 3.91
(KJ/cycle)

Cycle 195 GMT 18/12/2023 1:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 36 14.92 519 279 0.28 / 761.39 2 2
2 12 1175.96 4 15.19 1958 119 0.40 / 761.51 2 3
3 7 2004.92 34 14.79 2862 1439 1.84 / 762.95 3 2
4 13 1668.16 18 14.79 2493 664 2.50 / 763.61 2 3
5 13 997.32 18 14.84 1678 448 2.95 / 764.06 2 3
6 13 502.80 18 14.91 1034 278 3.23 / 764.34 2 4
7 8 0.16 165 14.98 344 850 4.08 / 765.19 2 12
Average= 3.90
(KJ/cycle)

Cycle 194 GMT 8/12/2023 3:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 36 14.93 530 285 0.28 / 757.35 2 2
2 12 1177.08 4 15.18 1961 119 0.40 / 757.47 2 3
3 7 2013.88 34 14.78 2868 1441 1.85 / 758.91 3 3
4 13 1514.84 18 14.80 2310 615 2.46 / 759.52 2 4
5 13 1038.72 18 14.83 1741 465 2.93 / 759.99 2 6
6 13 374.08 18 14.94 875 235 3.16 / 760.22 2 4
7 8 -0.04 165 14.99 360 890 4.05 / 761.11 2 12
Average= 3.90
(KJ/cycle)

Cycle 193 GMT 28/11/2023 5:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 36 14.92 514 276 0.28 / 753.23 2 2
2 12 1183.56 4 15.19 1969 120 0.40 / 753.35 2 3
3 7 2006.36 34 14.79 2850 1433 1.83 / 754.78 3 2
4 13 1518.80 18 14.80 2320 618 2.45 / 755.40 2 4
5 13 1029.16 18 14.83 1736 463 2.91 / 755.86 2 6
6 13 509.56 18 14.91 1058 284 3.19 / 756.15 2 5
7 8 0.16 165 14.98 371 917 4.11 / 757.06 2 13
Average= 3.90
(KJ/cycle)

Cycle 192 GMT 18/11/2023 7:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 36 14.93 514 276 0.28 / 749.09 2 2
2 12 1166.44 4 15.19 1949 118 0.39 / 749.21 2 3
3 7 2002.52 34 14.79 2858 1437 1.83 / 750.64 3 3
4 13 1507.84 18 14.80 2312 616 2.45 / 751.26 2 3
5 13 1179.56 18 14.80 1922 512 2.96 / 751.77 2 4
6 13 476.44 18 14.92 1028 276 3.24 / 752.05 2 5
7 8 0.12 165 14.98 366 905 4.14 / 752.95 2 12
Average= 3.90
(KJ/cycle)

Cycle 191 GMT 8/11/2023 9:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 36 14.93 524 282 0.28 / 744.99 2 2
2 12 1184.72 4 15.18 1973 120 0.40 / 745.11 2 3
3 7 2002.32 34 14.79 2852 1434 1.84 / 746.55 3 2
4 13 1517.36 18 14.80 2315 617 2.45 / 747.17 2 3
5 13 1018.08 18 14.84 1703 455 2.91 / 747.62 2 5
6 13 513.84 18 14.92 1055 283 3.19 / 747.90 2 4
7 8 0.16 165 14.98 367 907 4.10 / 748.81 2 10
Average= 3.90
(KJ/cycle)

Cycle 190 GMT 29/10/2023 11:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 36 14.94 507 273 0.27 / 740.97 2 2
2 12 1163.80 4 15.18 1941 118 0.39 / 741.09 2 3
3 7 2003.32 34 14.78 2855 1435 1.83 / 742.53 3 3
4 13 1507.96 18 14.81 2314 617 2.44 / 743.14 2 3
5 13 1003.68 18 14.84 1691 452 2.89 / 743.59 2 6
6 13 353.56 18 14.95 851 229 3.12 / 743.82 2 4
7 8 0.08 165 14.99 360 890 4.01 / 744.71 2 10
Average= 3.90
(KJ/cycle)

Cycle 189 GMT 19/10/2023 13:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 36 14.94 524 282 0.28 / 736.88 2 2
2 12 1176.84 4 15.19 1965 119 0.40 / 737.00 2 3
3 7 2005.64 34 14.79 2863 1440 1.84 / 738.44 3 3
4 13 1540.68 18 14.80 2360 629 2.47 / 739.07 2 3
5 13 1034.40 18 14.83 1740 464 2.93 / 739.53 2 4
6 13 526.08 18 14.91 1080 290 3.22 / 739.82 2 5
7 8 0.04 165 14.99 356 881 4.10 / 740.70 2 11
Average= 3.90
(KJ/cycle)

Cycle 188 GMT 9/10/2023 15:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 36 14.94 511 275 0.27 / 732.80 2 2
2 12 1174.40 4 15.18 1966 119 0.39 / 732.92 2 4
3 7 2003.24 34 14.79 2847 1432 1.83 / 734.35 4 3
4 13 1496.44 18 14.82 2294 612 2.44 / 734.96 2 3
5 13 1007.44 18 14.84 1702 455 2.89 / 735.41 2 5
6 13 498.28 18 14.92 1044 280 3.17 / 735.70 2 4
7 8 0.04 165 14.99 364 900 4.07 / 736.60 2 10
Average= 3.90
(KJ/cycle)

Cycle 187 GMT 29/ 9/2023 17:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 36 14.93 509 274 0.27 / 728.64 2 2
2 12 1166.36 4 15.19 1947 118 0.39 / 728.75 2 3
3 7 2006.40 34 14.79 2860 1438 1.83 / 730.19 3 3
4 13 1518.68 18 14.82 2315 618 2.45 / 730.81 2 2
5 13 1021.88 18 14.84 1718 459 2.91 / 731.27 2 5
6 13 380.36 18 14.95 886 238 3.14 / 731.51 2 5
7 8 0.24 165 14.99 357 883 4.03 / 732.39 2 11
8 14 0.24 25 14.97 352 132 4.16 / 732.52 4 13
Average= 3.90
(KJ/cycle)

Cycle 186 GMT 19/ 9/2023 19:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 36 14.94 512 275 0.28 / 724.42 2 2
2 12 1177.08 4 15.18 1969 120 0.39 / 724.54 2 3
3 7 2003.00 34 14.79 2860 1438 1.83 / 725.98 3 2
4 13 1513.40 18 14.81 2322 619 2.45 / 726.60 2 3
5 13 1167.76 18 14.81 1895 505 2.96 / 727.10 2 6
6 13 459.40 18 14.93 993 267 3.22 / 727.37 2 4
7 13 26.12 18 15.03 399 108 3.33 / 727.48 2 3
8 8 0.12 165 14.99 358 885 4.22 / 728.36 2 15
Average= 3.89
(KJ/cycle)

Cycle 185 GMT 9/ 9/2023 21:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 36 14.93 541 291 0.29 / 720.35 2 2
2 12 1169.60 4 15.18 1959 119 0.41 / 720.47 2 2
3 7 2002.40 34 14.79 2858 1437 1.85 / 721.90 2 2
4 13 1512.64 18 14.82 2314 617 2.46 / 722.52 2 3
5 13 1014.60 18 14.84 1704 455 2.92 / 722.98 2 5
6 13 501.64 18 14.92 1042 280 3.20 / 723.26 2 6
7 8 0.12 165 14.99 359 888 4.09 / 724.15 2 10
Average= 3.89
(KJ/cycle)

Cycle 184 GMT 30/ 8/2023 23: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 36 14.94 514 276 0.28 / 716.09 2 2
2 12 1165.56 4 15.19 1964 119 0.40 / 716.21 2 3
3 7 2004.08 34 14.79 2859 1438 1.83 / 717.65 3 4
4 13 1513.64 18 14.81 2318 618 2.45 / 718.27 2 4
5 13 1017.32 18 14.84 1715 458 2.91 / 718.73 2 7
6 13 363.84 18 14.95 884 238 3.15 / 718.96 2 3
7 8 0.08 165 14.99 384 950 4.10 / 719.91 2 13
8 14 0.08 25 14.95 388 145 4.24 / 720.06 2 16
Average= 3.89
(KJ/cycle)

Cycle 183 GMT 21/ 8/2023 0:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 36 14.94 501 269 0.27 / 712.03 2 2
2 12 1178.96 4 15.18 1969 120 0.39 / 712.15 2 3
3 7 2004.08 34 14.79 2851 1434 1.82 / 713.58 3 3
4 13 1512.20 18 14.81 2306 615 2.44 / 714.20 2 4
5 13 1027.52 18 14.84 1716 458 2.90 / 714.66 2 5
6 13 511.40 18 14.92 1048 281 3.18 / 714.94 2 4
7 8 0.20 165 14.99 355 878 4.06 / 715.82 2 9
Average= 3.89
(KJ/cycle)

Cycle 182 GMT 11/ 8/2023 2:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 36 14.95 513 276 0.28 / 707.92 2 2
2 12 1171.24 4 15.19 1968 120 0.40 / 708.04 2 3
3 7 2004.40 35 14.80 2852 1477 1.87 / 709.52 3 3
4 13 1498.92 18 14.81 2294 612 2.48 / 710.13 2 3
5 13 994.56 18 14.85 1691 452 2.94 / 710.59 2 4
6 13 486.20 18 14.93 1032 277 3.21 / 710.86 2 5
7 8 0.08 165 14.99 363 898 4.11 / 711.76 2 12
Average= 3.89
(KJ/cycle)

Cycle 181 GMT 1/ 8/2023 4:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 36 14.94 506 272 0.27 / 703.76 2 2
2 12 1161.60 4 15.19 1946 118 0.39 / 703.87 2 2
3 7 2004.48 35 14.79 2862 1482 1.87 / 705.36 2 3
4 13 1497.36 18 14.82 2291 611 2.48 / 705.97 2 4
5 13 1013.12 18 14.84 1711 457 2.94 / 706.42 2 7
6 13 347.80 18 14.96 845 228 3.17 / 706.65 2 3
7 13 42.76 18 15.03 420 114 3.28 / 706.77 2 3
8 8 0.04 165 14.99 357 883 4.16 / 707.65 2 13
Average= 3.89
(KJ/cycle)

Cycle 180 GMT 22/ 7/2023 6:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 36 14.95 502 270 0.27 / 699.69 2 2
2 12 1166.64 4 15.20 1950 119 0.39 / 699.81 2 2
3 7 2004.28 34 14.79 2856 1436 1.82 / 701.25 2 3
4 13 1510.72 18 14.81 2314 617 2.44 / 701.86 2 3
5 13 1016.72 18 14.84 1710 457 2.90 / 702.32 2 6
6 13 507.56 18 14.92 1057 284 3.18 / 702.60 2 4
7 8 -0.04 165 14.99 356 881 4.06 / 703.48 2 11
Average= 3.89
(KJ/cycle)

Cycle 179 GMT 12/ 7/2023 8:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 36 14.94 519 279 0.28 / 695.67 2 2
2 12 1171.96 4 15.20 1950 119 0.40 / 695.79 2 3
3 7 2004.20 34 14.79 2861 1439 1.84 / 697.23 3 3
4 13 1515.52 18 14.81 2322 619 2.46 / 697.85 2 3
5 13 1031.36 18 14.84 1735 463 2.92 / 698.31 2 5
6 13 376.44 18 14.95 882 237 3.16 / 698.55 2 4
7 8 0.00 165 15.00 352 871 4.03 / 699.42 2 12
Average= 3.89
(KJ/cycle)

Cycle 178 GMT 2/ 7/2023 10:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 36 14.93 520 279 0.28 / 691.59 2 2
2 12 1157.88 4 15.19 1943 118 0.40 / 691.71 2 3
3 7 2003.32 34 14.79 2869 1443 1.84 / 693.15 3 3
4 13 1511.84 18 14.82 2314 617 2.46 / 693.77 2 3
5 13 1013.52 18 14.85 1706 456 2.91 / 694.23 2 5
6 13 496.64 18 14.92 1037 278 3.19 / 694.51 2 6
7 8 0.12 165 14.99 359 888 4.08 / 695.39 2 11
Average= 3.88
(KJ/cycle)

Cycle 177 GMT 22/ 6/2023 12:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 36 14.94 510 274 0.27 / 687.38 2 2
2 12 1173.64 4 15.20 1962 119 0.39 / 687.50 2 3
3 7 2002.76 34 14.80 2839 1429 1.82 / 688.93 3 3
4 13 1516.60 18 14.81 2313 617 2.44 / 689.55 2 3
5 13 1026.68 18 14.84 1736 464 2.90 / 690.01 2 5
6 13 517.84 18 14.92 1079 290 3.19 / 690.30 2 5
7 13 70.24 18 15.02 457 124 3.32 / 690.43 2 3
8 8 0.12 165 14.99 359 888 4.20 / 691.31 2 12
Average= 3.88
(KJ/cycle)

Cycle 176 GMT 12/ 6/2023 14:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 36 14.95 508 273 0.27 / 683.20 2 2
2 12 1177.72 4 15.19 1962 119 0.39 / 683.32 2 3
3 7 2004.60 34 14.80 2873 1446 1.84 / 684.77 3 3
4 13 1517.12 18 14.82 2316 618 2.46 / 685.39 2 3
5 13 1023.64 18 14.85 1718 459 2.92 / 685.85 2 5
6 13 506.76 18 14.92 1048 281 3.20 / 686.13 2 5
7 13 29.08 18 15.04 385 104 3.30 / 686.23 2 3
8 8 0.00 165 14.99 355 878 4.18 / 687.11 2 10
Average= 3.88
(KJ/cycle)

Cycle 175 GMT 2/ 6/2023 16:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 36 14.95 518 279 0.28 / 679.12 2 2
2 12 1163.20 4 15.19 1957 119 0.40 / 679.24 2 3
3 7 2006.20 34 14.79 2861 1439 1.84 / 680.68 3 3
4 13 1509.00 18 14.82 2310 616 2.45 / 681.29 2 4
5 13 1019.24 18 14.85 1717 459 2.91 / 681.75 2 6
6 13 496.08 18 14.93 1043 280 3.19 / 682.03 2 5
7 8 0.08 165 15.00 363 898 4.09 / 682.93 2 11
Average= 3.88
(KJ/cycle)

Cycle 174 GMT 23/ 5/2023 18:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 36 14.95 508 273 0.27 / 675.05 2 2
2 12 1183.64 4 15.19 1977 120 0.39 / 675.17 2 3
3 7 2001.48 34 14.79 2851 1434 1.83 / 676.60 3 2
4 13 1495.36 18 14.82 2298 613 2.44 / 677.22 2 3
5 13 1000.00 18 14.85 1694 453 2.89 / 677.67 2 5
6 13 489.00 18 14.93 1027 276 3.17 / 677.95 2 5
7 8 0.08 165 15.00 362 896 4.06 / 678.84 2 9
Average= 3.88
(KJ/cycle)

Cycle 173 GMT 13/ 5/2023 20:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 36 14.95 494 266 0.27 / 670.98 2 2
2 12 1165.92 4 15.21 1957 119 0.38 / 671.10 2 3
3 7 2004.68 34 14.80 2857 1438 1.82 / 672.54 3 3
4 13 1505.96 18 14.83 2312 617 2.44 / 673.15 2 3
5 13 1018.52 18 14.85 1705 456 2.90 / 673.61 2 5
6 13 509.20 18 14.93 1055 284 3.18 / 673.89 2 4
7 8 0.36 165 15.00 357 884 4.06 / 674.78 2 8
Average= 3.88
(KJ/cycle)

Cycle 172 GMT 3/ 5/2023 22: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 36 14.94 496 267 0.27 / 666.80 2 2
2 12 1175.04 4 15.20 1958 119 0.39 / 666.92 2 3
3 7 2008.32 34 14.80 2862 1440 1.83 / 668.36 3 3
4 13 1518.48 18 14.82 2317 618 2.44 / 668.98 2 2
5 13 1021.20 18 14.85 1709 457 2.90 / 669.43 2 7
6 13 497.68 18 14.93 1029 277 3.18 / 669.71 2 4
7 13 62.84 18 15.03 431 117 3.29 / 669.83 2 3
8 8 -0.28 165 14.99 359 888 4.18 / 670.71 2 21
Average= 3.88
(KJ/cycle)

Cycle 171 GMT 23/ 4/2023 23:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 36 14.95 492 265 0.26 / 662.67 2 2
2 12 1173.12 4 15.20 1969 120 0.38 / 662.79 2 3
3 7 2001.88 34 14.81 2844 1432 1.82 / 664.22 3 3
4 13 1491.16 18 14.83 2285 610 2.43 / 664.83 2 3
5 13 995.16 18 14.86 1683 450 2.88 / 665.28 2 5
6 13 477.52 18 14.94 1010 272 3.15 / 665.55 2 6
7 13 54.64 18 15.03 424 115 3.26 / 665.67 2 3
8 8 0.40 165 15.00 350 866 4.13 / 666.53 2 11
Average= 3.88
(KJ/cycle)

Cycle 170 GMT 14/ 4/2023 1:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 36 14.95 494 266 0.27 / 658.54 2 2
2 12 1174.28 4 15.20 1977 120 0.39 / 658.66 2 3
3 7 2006.60 34 14.80 2850 1434 1.82 / 660.10 3 3
4 13 1517.00 18 14.82 2322 619 2.44 / 660.72 2 3
5 13 1011.36 18 14.85 1717 459 2.90 / 661.18 2 5
6 13 377.36 18 14.96 885 238 3.14 / 661.41 2 4
7 13 42.04 18 15.04 414 112 3.25 / 661.53 2 3
8 8 -0.08 165 15.00 354 876 4.13 / 662.40 2 10
Average= 3.87
(KJ/cycle)

Cycle 169 GMT 4/ 4/2023 3:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 36 14.96 497 268 0.27 / 654.46 2 2
2 12 1185.64 4 15.19 1963 119 0.39 / 654.58 2 2
3 7 2003.48 34 14.80 2836 1427 1.81 / 656.00 2 2
4 13 1513.92 18 14.82 2307 615 2.43 / 656.62 2 2
5 13 1021.16 18 14.86 1712 458 2.89 / 657.08 2 6
6 13 370.76 18 14.96 862 232 3.12 / 657.31 2 4
7 13 40.08 18 15.04 402 109 3.23 / 657.42 2 3
8 8 0.12 165 15.00 347 859 4.09 / 658.28 2 12
Average= 3.87
(KJ/cycle)

Cycle 168 GMT 25/ 3/2023 5:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 36 14.96 501 270 0.27 / 650.37 2 2
2 12 1165.28 4 15.20 1947 118 0.39 / 650.48 2 3
3 7 2005.36 34 14.80 2854 1436 1.82 / 651.92 3 3
4 13 1518.20 18 14.83 2312 617 2.44 / 652.54 2 2
5 13 1015.32 18 14.86 1703 456 2.90 / 652.99 2 4
6 13 364.08 18 14.97 857 231 3.13 / 653.22 2 3
7 13 39.76 18 15.04 405 110 3.24 / 653.33 2 3
8 8 0.04 165 15.00 346 856 4.09 / 654.19 2 10
Average= 3.87
(KJ/cycle)

Cycle 167 GMT 15/ 3/2023 7:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 36 14.94 516 278 0.28 / 646.27 2 2
2 12 1180.68 4 15.19 1973 120 0.40 / 646.39 2 3
3 7 2001.96 34 14.80 2852 1435 1.83 / 647.82 3 2
4 13 1511.04 18 14.83 2304 615 2.45 / 648.44 2 3
5 13 1003.16 18 14.86 1680 449 2.90 / 648.89 2 5
6 13 356.12 18 14.97 838 226 3.12 / 649.11 2 4
7 13 37.88 18 15.04 406 110 3.23 / 649.22 2 3
8 8 0.04 165 15.01 352 872 4.10 / 650.10 2 12
Average= 3.87
(KJ/cycle)

Cycle 166 GMT 5/ 3/2023 9: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 35 14.95 514 269 0.27 / 642.08 2 2
2 12 1174.04 4 15.20 1964 119 0.39 / 642.20 2 4
3 7 2001.92 34 14.81 2857 1439 1.83 / 643.64 4 3
4 13 1509.40 18 14.82 2308 616 2.44 / 644.25 2 3
5 13 1015.00 18 14.86 1708 457 2.90 / 644.71 2 4
6 13 505.80 18 14.93 1048 282 3.18 / 644.99 2 4
7 13 59.92 18 15.03 437 118 3.30 / 645.11 2 3
8 8 -0.16 165 15.00 356 881 4.18 / 645.99 2 12
Average= 3.87
(KJ/cycle)

Cycle 165 GMT 23/ 2/2023 10:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 35 14.96 510 267 0.27 / 637.94 2 2
2 12 1176.96 4 15.21 1955 119 0.39 / 638.05 2 2
3 7 2001.72 34 14.80 2849 1434 1.82 / 639.49 2 3
4 13 1495.88 18 14.83 2291 612 2.43 / 640.10 2 3
5 13 1003.12 18 14.86 1681 450 2.88 / 640.55 2 4
6 13 498.04 18 14.94 1030 277 3.16 / 640.83 2 4
7 13 33.20 18 15.04 385 104 3.26 / 640.93 2 3
8 8 0.24 165 15.00 356 881 4.14 / 641.81 2 13
Average= 3.87
(KJ/cycle)

Cycle 164 GMT 13/ 2/2023 12:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 35 14.96 507 265 0.27 / 633.73 2 2
2 12 1177.72 4 15.20 1978 120 0.39 / 633.86 2 3
3 7 2002.72 34 14.81 2851 1436 1.82 / 635.29 3 4
4 13 1665.24 18 14.81 2514 670 2.49 / 635.96 2 3
5 13 968.28 18 14.87 1663 445 2.94 / 636.41 2 5
6 13 461.68 18 14.95 996 268 3.20 / 636.67 2 5
7 13 32.20 18 15.05 397 108 3.31 / 636.78 2 3
8 8 0.20 165 15.01 358 887 4.20 / 637.67 2 13
Average= 3.86
(KJ/cycle)

Cycle 163 GMT 3/ 2/2023 14:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 35 14.96 500 262 0.26 / 629.54 2 2
2 12 1183.04 4 15.19 1964 119 0.38 / 629.66 2 2
3 7 2003.80 34 14.81 2851 1436 1.82 / 631.09 2 3
4 13 1653.08 18 14.82 2490 664 2.48 / 631.76 2 4
5 13 973.20 18 14.87 1661 445 2.93 / 632.20 2 5
6 13 470.56 18 14.95 1017 274 3.20 / 632.48 2 4
7 13 27.52 18 15.05 396 107 3.31 / 632.58 2 3
8 8 -0.08 165 15.01 358 887 4.19 / 633.47 2 14
Average= 3.86
(KJ/cycle)

Cycle 162 GMT 24/ 1/2023 16:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 35 14.97 505 265 0.26 / 625.38 2 2
2 12 1168.16 4 15.21 1946 118 0.38 / 625.50 2 2
3 7 2006.40 34 14.80 2864 1441 1.82 / 626.94 2 3
4 13 1498.76 18 14.83 2296 613 2.44 / 627.55 2 3
5 13 1015.12 18 14.86 1720 460 2.90 / 628.01 2 5
6 13 497.08 18 14.94 1058 285 3.18 / 628.30 2 5
7 13 27.76 18 15.05 394 107 3.29 / 628.40 2 3
8 8 -0.08 165 15.01 353 874 4.16 / 629.28 2 12
Average= 3.86
(KJ/cycle)

Cycle 161 GMT 14/ 1/2023 18:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 35 14.96 495 259 0.26 / 621.37 2 2
2 12 1178.24 4 15.20 1982 121 0.38 / 621.49 2 3
3 7 2003.56 35 14.80 2853 1478 1.86 / 622.97 3 3
4 13 1496.16 18 14.83 2281 609 2.47 / 623.58 2 4
5 13 990.80 18 14.86 1677 449 2.91 / 624.03 2 5
6 13 330.84 18 14.98 814 219 3.13 / 624.25 2 4
7 8 0.28 165 15.02 350 867 4.00 / 625.11 2 10
Average= 3.86
(KJ/cycle)

Cycle 160 GMT 4/ 1/2023 20:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 35 14.96 519 272 0.27 / 617.19 2 2
2 12 1166.80 4 15.20 1947 118 0.39 / 617.31 2 3
3 7 2003.64 34 14.81 2849 1435 1.82 / 618.74 3 2
4 13 1519.00 18 14.83 2315 618 2.44 / 619.36 2 3
5 13 1017.76 18 14.86 1719 460 2.90 / 619.82 2 5
6 13 507.04 18 14.94 1065 286 3.19 / 620.10 2 5
7 13 27.68 18 15.05 393 106 3.30 / 620.21 2 3
8 8 -0.04 165 15.01 364 902 4.20 / 621.11 2 12
Average= 3.86
(KJ/cycle)

Cycle 159 GMT 25/12/2022 22:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 35 14.98 487 255 0.26 / 613.10 2 2
2 12 1175.88 4 15.20 1953 119 0.37 / 613.22 2 3
3 7 2002.12 34 14.81 2863 1442 1.82 / 614.66 3 3
4 13 1388.24 18 14.84 2185 584 2.40 / 615.25 2 4
5 13 1069.96 18 14.84 1784 477 2.88 / 615.72 2 6
6 13 536.28 18 14.93 1111 299 3.17 / 616.02 2 5
7 8 0.28 165 15.02 360 892 4.07 / 616.91 2 10
Average= 3.86
(KJ/cycle)

Cycle 158 GMT 16/12/2022 0:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 35 14.98 501 263 0.26 / 609.13 2 2
2 12 1163.08 4 15.20 1949 118 0.38 / 609.24 2 3
3 7 2004.96 34 14.81 2853 1437 1.82 / 610.68 3 3
4 13 1508.08 18 14.83 2312 617 2.43 / 611.30 2 4
5 13 1022.12 18 14.86 1728 462 2.90 / 611.76 2 5
6 13 375.24 18 14.98 874 236 3.13 / 612.00 2 3
7 8 0.12 165 15.03 344 853 3.99 / 612.85 2 10
Average= 3.85
(KJ/cycle)

Cycle 157 GMT 6/12/2022 2: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 35 14.97 499 261 0.26 / 605.09 2 2
2 12 1162.52 4 15.21 1965 120 0.38 / 605.21 2 3
3 7 2006.76 34 14.82 2860 1441 1.82 / 606.66 3 3
4 13 1518.12 18 14.84 2327 622 2.44 / 607.28 2 4
5 13 1008.24 18 14.87 1698 454 2.90 / 607.73 2 5
6 13 479.72 18 14.96 1013 273 3.17 / 608.00 2 5
7 8 0.08 165 15.03 346 858 4.03 / 608.86 2 9
Average= 3.85
(KJ/cycle)

Cycle 156 GMT 26/11/2022 3:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 35 14.98 502 263 0.26 / 601.06 2 2
2 12 1181.76 4 15.20 1968 120 0.38 / 601.18 2 2
3 7 2003.20 34 14.81 2849 1435 1.82 / 602.62 2 3
4 13 1498.80 18 14.83 2291 612 2.43 / 603.23 2 3
5 13 997.52 18 14.87 1687 452 2.88 / 603.68 2 5
6 13 490.64 18 14.95 1034 278 3.16 / 603.96 2 5
7 8 0.08 165 15.02 353 875 4.03 / 604.83 2 11
Average= 3.85
(KJ/cycle)

Cycle 155 GMT 16/11/2022 5:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 35 14.98 490 257 0.26 / 597.10 2 2
2 12 1168.20 4 15.20 1947 118 0.38 / 597.22 2 3
3 7 2002.88 34 14.80 2850 1434 1.81 / 598.65 3 2
4 13 1507.96 18 14.83 2311 617 2.43 / 599.27 2 4
5 13 997.48 18 14.87 1689 452 2.88 / 599.72 2 6
6 13 342.36 18 14.99 826 223 3.10 / 599.94 2 4
7 8 -0.12 165 15.03 345 856 3.96 / 600.80 2 12
Average= 3.85
(KJ/cycle)

Cycle 154 GMT 6/11/2022 7:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 35 14.98 488 256 0.26 / 593.10 2 2
2 12 1176.52 4 15.20 1956 119 0.37 / 593.22 2 3
3 7 2003.92 34 14.81 2860 1440 1.81 / 594.66 3 2
4 13 1508.12 18 14.83 2308 616 2.43 / 595.27 2 3
5 13 1013.60 18 14.87 1701 455 2.89 / 595.73 2 5
6 13 488.56 18 14.95 1037 279 3.17 / 596.01 2 5
7 8 0.32 165 15.03 337 836 4.00 / 596.84 2 9
Average= 3.85
(KJ/cycle)

Cycle 153 GMT 27/10/2022 9:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 35 14.97 493 258 0.26 / 589.13 2 2
2 12 1175.44 4 15.21 1969 120 0.38 / 589.25 2 3
3 7 2003.48 34 14.81 2848 1434 1.81 / 590.68 3 3
4 13 1508.84 18 14.83 2318 619 2.43 / 591.30 2 3
5 13 1012.08 18 14.87 1707 457 2.89 / 591.76 2 4
6 13 361.96 18 14.99 852 230 3.12 / 591.99 2 3
7 8 -0.16 165 15.03 344 853 3.97 / 592.84 2 10
Average= 3.85
(KJ/cycle)

Cycle 152 GMT 17/10/2022 11:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 35 14.96 497 260 0.26 / 585.13 2 2
2 12 1183.00 4 15.20 1971 120 0.38 / 585.25 2 3
3 7 2006.56 34 14.81 2853 1437 1.82 / 586.69 3 3
4 13 1520.36 18 14.83 2323 620 2.44 / 587.31 2 4
5 13 1031.52 18 14.85 1732 463 2.90 / 587.77 2 5
6 13 385.80 18 14.98 877 236 3.14 / 588.01 2 3
7 8 0.04 165 15.02 349 865 4.00 / 588.87 2 12
Average= 3.85
(KJ/cycle)

Cycle 151 GMT 7/10/2022 13: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 35 14.98 494 259 0.26 / 580.87 2 2
2 12 1176.88 4 15.22 1948 119 0.38 / 580.99 2 2
3 7 2006.88 35 14.81 2853 1479 1.86 / 582.47 2 3
4 13 1664.24 18 14.81 2479 661 2.52 / 583.13 2 3
5 13 972.96 18 14.87 1649 441 2.96 / 583.57 2 5
6 13 474.56 18 14.95 1010 272 3.23 / 583.84 2 4
7 8 0.20 165 15.02 360 892 4.12 / 584.73 2 9
8 14 0.20 25 14.99 364 136 4.26 / 584.87 2 12
Average= 3.85
(KJ/cycle)

Cycle 150 GMT 27/ 9/2022 14:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 35 14.99 477 250 0.25 / 576.88 2 2
2 12 1188.44 4 15.22 1981 121 0.37 / 577.00 2 3
3 7 2002.00 34 14.82 2850 1436 1.81 / 578.44 3 3
4 13 1508.60 18 14.85 2306 616 2.42 / 579.05 2 2
5 13 1008.32 18 14.88 1692 453 2.88 / 579.50 2 6
6 13 492.60 18 14.96 1039 280 3.16 / 579.78 2 5
7 8 0.08 165 15.04 333 826 3.98 / 580.61 2 11
Average= 3.85
(KJ/cycle)

Cycle 149 GMT 17/ 9/2022 17: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 35 14.98 495 260 0.26 / 572.92 2 2
2 12 1175.32 4 15.21 1976 120 0.38 / 573.04 2 3
3 7 2006.56 34 14.82 2878 1450 1.83 / 574.49 3 3
4 13 1521.96 18 14.84 2314 618 2.45 / 575.11 2 3
5 13 1020.40 18 14.87 1710 458 2.91 / 575.57 2 4
6 13 350.56 18 15.00 831 224 3.13 / 575.79 2 3
7 8 -0.08 165 15.04 336 834 3.96 / 576.63 2 10
Average= 3.84
(KJ/cycle)

Cycle 148 GMT 7/ 9/2022 18:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 35 14.98 490 257 0.26 / 568.91 2 2
2 12 1174.64 4 15.22 1950 119 0.38 / 569.03 2 4
3 7 2005.48 34 14.81 2861 1441 1.82 / 570.47 4 3
4 13 1510.20 18 14.85 2305 616 2.43 / 571.08 2 4
5 13 1015.32 18 14.87 1708 457 2.89 / 571.54 2 5
6 13 502.80 18 14.96 1045 281 3.17 / 571.82 2 4
7 8 0.24 165 15.04 339 841 4.01 / 572.66 2 8
Average= 3.84
(KJ/cycle)

Cycle 147 GMT 28/ 8/2022 20:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 35 14.98 501 263 0.26 / 564.88 2 2
2 12 1166.32 4 15.22 1963 120 0.38 / 565.00 2 3
3 7 2008.60 34 14.82 2853 1438 1.82 / 566.43 3 3
4 13 1518.56 18 14.84 2324 621 2.44 / 567.05 2 4
5 13 1022.08 18 14.87 1716 459 2.90 / 567.51 2 4
6 13 524.16 18 14.95 1063 286 3.19 / 567.80 2 6
7 8 0.40 165 15.03 344 853 4.04 / 568.65 2 11
Average= 3.84
(KJ/cycle)

Cycle 146 GMT 18/ 8/2022 22:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 35 14.99 493 259 0.26 / 560.85 2 2
2 12 1177.52 4 15.21 1969 120 0.38 / 560.97 2 2
3 7 2005.08 34 14.82 2855 1439 1.82 / 562.41 2 3
4 13 1500.60 18 14.84 2296 613 2.43 / 563.03 2 3
5 13 1004.32 18 14.88 1695 454 2.88 / 563.48 2 4
6 13 485.00 18 14.96 1030 277 3.16 / 563.76 2 5
7 8 0.16 165 15.04 345 856 4.02 / 564.61 2 11
Average= 3.84
(KJ/cycle)

Cycle 145 GMT 9/ 8/2022 0:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 35 14.99 490 257 0.26 / 556.88 2 2
2 12 1178.68 4 15.22 1974 120 0.38 / 557.00 2 2
3 7 2009.04 34 14.82 2864 1443 1.82 / 558.45 2 3
4 13 1518.36 18 14.84 2325 621 2.44 / 559.07 2 4
5 13 1027.28 18 14.87 1716 459 2.90 / 559.53 2 7
6 13 365.16 18 15.00 846 228 3.13 / 559.75 2 4
7 8 0.04 165 15.04 339 841 3.97 / 560.60 2 12
Average= 3.84
(KJ/cycle)

Cycle 144 GMT 30/ 7/2022 2:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 35 14.98 491 257 0.26 / 552.80 2 2
2 12 1192.36 4 15.21 1979 120 0.38 / 552.92 2 3
3 7 2001.52 34 14.82 2858 1440 1.82 / 554.36 3 2
4 13 1503.80 18 14.85 2303 616 2.43 / 554.98 2 3
5 13 1014.68 18 14.88 1707 457 2.89 / 555.44 2 5
6 13 347.80 18 15.00 823 222 3.11 / 555.66 2 4
7 8 0.36 165 15.04 338 839 3.95 / 556.50 2 9
8 14 0.36 25 15.02 339 127 4.08 / 556.62 2 12
Average= 3.84
(KJ/cycle)

Cycle 143 GMT 20/ 7/2022 4:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 35 14.99 495 260 0.26 / 548.53 2 2
2 12 1168.08 4 15.21 1959 119 0.38 / 548.65 2 3
3 7 2003.96 34 14.82 2856 1439 1.82 / 550.09 3 3
4 13 1524.72 18 14.84 2326 621 2.44 / 550.71 2 3
5 13 1025.52 18 14.87 1720 460 2.90 / 551.17 2 6
6 13 513.44 18 14.96 1050 283 3.18 / 551.45 2 6
7 13 65.84 18 15.06 439 119 3.30 / 551.57 2 3
8 8 0.16 165 15.03 342 848 4.15 / 552.42 2 11
9 14 0.16 25 15.01 343 129 4.28 / 552.55 4 11
Average= 3.84
(KJ/cycle)

Cycle 142 GMT 10/ 7/2022 6:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 35 14.99 491 258 0.26 / 544.43 2 2
2 12 1170.44 4 15.22 1961 119 0.38 / 544.55 2 2
3 7 2005.64 34 14.82 2850 1436 1.81 / 545.98 2 3
4 13 1507.04 18 14.85 2309 617 2.43 / 546.60 2 3
5 13 1009.08 18 14.88 1697 455 2.88 / 547.05 2 5
6 13 482.08 18 14.97 1011 272 3.16 / 547.33 2 3
7 13 28.20 18 15.07 380 103 3.26 / 547.43 2 3
8 8 0.44 165 15.04 338 839 4.10 / 548.27 2 10
Average= 3.83
(KJ/cycle)

Cycle 141 GMT 30/ 6/2022 8:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 35 14.98 508 266 0.27 / 540.39 2 2
2 12 1179.08 4 15.21 1965 120 0.39 / 540.51 2 3
3 7 2003.64 34 14.82 2861 1442 1.83 / 541.95 3 3
4 13 1504.48 18 14.85 2312 618 2.45 / 542.57 2 4
5 13 996.64 18 14.88 1693 453 2.90 / 543.02 2 5
6 13 475.40 18 14.97 1011 272 3.17 / 543.29 2 4
7 8 0.00 165 15.04 352 874 4.04 / 544.17 2 12
Average= 3.83
(KJ/cycle)

Cycle 140 GMT 20/ 6/2022 10:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 35 14.99 493 259 0.26 / 536.34 2 2
2 12 1165.72 4 15.22 1947 119 0.38 / 536.45 2 3
3 7 2002.04 34 14.83 2853 1439 1.82 / 537.89 3 3
4 13 1503.40 18 14.85 2296 614 2.43 / 538.51 2 4
5 13 1007.40 18 14.88 1699 455 2.88 / 538.96 2 5
6 13 479.44 18 14.97 1008 272 3.16 / 539.23 2 5
7 8 0.36 165 15.04 359 891 4.05 / 540.12 2 8
Average= 3.83
(KJ/cycle)

Cycle 139 GMT 10/ 6/2022 12:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 35 15.01 474 249 0.25 / 532.09 2 2
2 12 1191.20 4 15.21 1974 120 0.37 / 532.21 2 3
3 7 2005.16 34 14.83 2853 1439 1.81 / 533.65 3 3
4 13 1667.16 18 14.83 2486 664 2.47 / 534.32 2 2
5 13 979.20 18 14.89 1652 443 2.91 / 534.76 2 6
6 13 330.64 18 15.02 798 216 3.13 / 534.97 2 3
7 13 36.64 18 15.08 390 106 3.24 / 535.08 2 3
8 8 0.16 165 15.04 348 864 4.10 / 535.94 2 12
9 14 0.16 25 15.01 354 133 4.23 / 536.08 2 11
Average= 3.83
(KJ/cycle)

Cycle 138 GMT 31/ 5/2022 14: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 35 15.00 498 261 0.26 / 527.89 2 2
2 12 1181.76 4 15.22 1961 119 0.38 / 528.01 2 3
3 7 2005.48 34 14.83 2857 1441 1.82 / 529.45 3 3
4 13 1505.44 18 14.85 2303 616 2.44 / 530.06 2 3
5 13 1011.08 18 14.88 1698 455 2.89 / 530.52 2 5
6 13 493.52 18 14.97 1019 275 3.17 / 530.79 2 5
7 13 65.88 18 15.07 432 117 3.28 / 530.91 2 3
8 8 -0.48 165 15.04 327 811 4.10 / 531.72 2 10
9 14 -0.48 25 15.02 327 123 4.22 / 531.84 2 11
Average= 3.83
(KJ/cycle)

Cycle 137 GMT 21/ 5/2022 15:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 35 15.01 488 256 0.26 / 523.74 2 2
2 12 1179.12 4 15.21 1978 120 0.38 / 523.86 2 2
3 7 2003.56 34 14.83 2857 1441 1.82 / 525.30 2 3
4 13 1512.36 18 14.84 2313 618 2.44 / 525.92 2 3
5 13 1019.16 18 14.89 1715 460 2.89 / 526.38 2 5
6 13 488.72 18 14.97 1021 275 3.17 / 526.66 2 4
7 8 -0.04 165 15.05 339 842 4.01 / 527.50 2 12
8 14 -0.04 25 15.03 341 128 4.14 / 527.63 3 14
Average= 3.82
(KJ/cycle)

Cycle 136 GMT 11/ 5/2022 17:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 35 14.99 505 265 0.26 / 519.76 2 2
2 12 1169.44 4 15.23 1974 120 0.39 / 519.88 2 3
3 7 2003.48 34 14.83 2853 1439 1.82 / 521.32 3 3
4 13 1485.64 18 14.86 2281 610 2.43 / 521.93 2 4
5 13 987.32 18 14.90 1669 448 2.88 / 522.37 2 4
6 13 485.72 18 14.98 1018 274 3.16 / 522.65 2 5
7 8 0.24 165 15.06 337 837 3.99 / 523.49 2 11
Average= 3.82
(KJ/cycle)

Cycle 135 GMT 1/ 5/2022 19:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 35 15.00 481 253 0.25 / 515.58 2 2
2 12 1168.24 4 15.22 1956 119 0.37 / 515.70 2 3
3 7 2004.12 34 14.83 2844 1434 1.81 / 517.14 3 3
4 13 1517.36 18 14.85 2317 619 2.42 / 517.76 2 3
5 13 1015.12 18 14.89 1700 456 2.88 / 518.21 2 6
6 13 506.72 18 14.97 1047 282 3.16 / 518.49 2 5
7 13 26.00 18 15.08 395 107 3.27 / 518.60 2 3
8 8 0.00 165 15.04 360 893 4.16 / 519.49 2 14
Average= 3.82
(KJ/cycle)

Cycle 134 GMT 21/ 4/2022 21:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 35 14.99 476 250 0.25 / 511.53 2 2
2 12 1168.32 4 15.23 1964 120 0.37 / 511.65 2 2
3 7 2004.40 34 14.83 2869 1447 1.82 / 513.10 2 3
4 13 1385.92 18 14.87 2159 578 2.39 / 513.67 2 3
5 13 1059.08 18 14.88 1754 470 2.86 / 514.14 2 5
6 13 383.60 18 15.01 875 236 3.10 / 514.38 2 3
7 13 44.48 18 15.08 407 110 3.21 / 514.49 2 3
8 8 0.16 165 15.05 338 839 4.05 / 515.33 2 9
Average= 3.82
(KJ/cycle)

Cycle 133 GMT 11/ 4/2022 22:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 35 15.00 466 245 0.24 / 507.53 2 2
2 12 1170.56 4 15.22 1973 120 0.36 / 507.65 2 2
3 7 2005.80 34 14.83 2855 1440 1.80 / 509.09 2 3
4 13 1380.20 18 14.87 2158 578 2.38 / 509.67 2 3
5 13 920.44 18 14.91 1582 425 2.81 / 510.09 2 4
6 13 413.96 18 14.99 921 249 3.06 / 510.34 2 6
7 13 22.48 18 15.08 380 103 3.16 / 510.45 2 3
8 8 0.00 165 15.05 336 834 3.99 / 511.28 2 9
Average= 3.82
(KJ/cycle)

Cycle 132 GMT 2/ 4/2022 0:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 35 15.00 477 250 0.25 / 503.32 2 2
2 12 1161.12 4 15.22 1937 118 0.37 / 503.44 2 3
3 7 2004.00 34 14.83 2852 1438 1.81 / 504.88 3 3
4 13 1500.80 18 14.85 2291 612 2.42 / 505.49 2 4
5 13 1000.08 18 14.89 1681 451 2.87 / 505.94 2 4
6 13 485.96 18 14.98 1017 274 3.14 / 506.21 2 4
7 13 53.96 18 15.08 426 116 3.26 / 506.33 2 3
8 8 0.12 165 15.05 335 832 4.09 / 507.16 2 10
9 14 0.12 25 15.03 336 126 4.22 / 507.29 3 13
Average= 3.81
(KJ/cycle)

Cycle 131 GMT 23/ 3/2022 2: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 35 15.01 477 251 0.25 / 499.24 2 2
2 12 1153.32 4 15.23 1944 118 0.37 / 499.36 2 3
3 7 2003.00 34 14.83 2849 1437 1.81 / 500.80 3 3
4 13 1507.04 18 14.85 2307 617 2.42 / 501.41 2 3
5 13 1017.64 18 14.89 1704 457 2.88 / 501.87 2 6
6 13 490.28 18 14.98 1018 274 3.15 / 502.15 2 5
7 13 34.20 18 15.08 387 105 3.26 / 502.25 2 3
8 8 -0.08 165 15.05 330 819 4.08 / 503.07 2 10
Average= 3.81
(KJ/cycle)

Cycle 130 GMT 13/ 3/2022 3:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 35 15.02 471 248 0.25 / 495.15 2 2
2 12 1170.48 4 15.22 1956 119 0.37 / 495.27 2 3
3 7 2007.12 34 14.82 2864 1443 1.81 / 496.71 3 2
4 13 1516.24 18 14.86 2314 619 2.43 / 497.33 2 3
5 13 1010.56 18 14.89 1695 454 2.88 / 497.79 2 5
6 13 497.48 18 14.98 1028 277 3.16 / 498.06 2 5
7 13 32.36 18 15.09 386 105 3.27 / 498.17 2 3
8 8 0.04 165 15.05 332 824 4.09 / 498.99 2 12
Average= 3.81
(KJ/cycle)

Cycle 129 GMT 3/ 3/2022 5:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 35 15.01 482 253 0.25 / 491.12 2 2
2 12 1178.24 4 15.23 1965 120 0.37 / 491.24 2 3
3 7 2007.76 34 14.83 2858 1441 1.81 / 492.68 3 3
4 13 1505.24 18 14.86 2307 617 2.43 / 493.30 2 2
5 13 1003.00 18 14.90 1686 452 2.88 / 493.75 2 4
6 13 358.12 18 15.02 838 227 3.11 / 493.97 2 4
7 13 20.80 18 15.10 372 101 3.21 / 494.08 2 3
8 8 0.16 165 15.06 333 827 4.04 / 494.90 2 14
Average= 3.81
(KJ/cycle)

Cycle 128 GMT 21/ 2/2022 7:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 35 15.01 483 254 0.25 / 487.00 2 2
2 12 1177.72 4 15.21 1977 120 0.37 / 487.12 2 3
3 7 2002.12 34 14.84 2865 1446 1.82 / 488.56 3 3
4 13 1656.60 18 14.84 2478 662 2.48 / 489.22 2 3
5 13 978.40 18 14.90 1656 444 2.93 / 489.67 2 3
6 13 464.84 18 15.00 984 266 3.19 / 489.93 2 4
7 13 24.04 18 15.10 379 103 3.29 / 490.04 2 3
8 8 0.04 165 15.06 333 827 4.12 / 490.86 2 11
Average= 3.81
(KJ/cycle)

Cycle 127 GMT 11/ 2/2022 9:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 35 15.00 503 264 0.26 / 482.87 2 2
2 12 1176.76 4 15.22 1970 120 0.38 / 482.99 2 2
3 7 2006.00 35 14.82 2858 1482 1.87 / 484.47 2 2
4 13 1494.36 18 14.86 2298 615 2.48 / 485.08 2 3
5 13 992.12 18 14.90 1681 451 2.93 / 485.53 2 4
6 13 480.24 18 14.98 1011 273 3.20 / 485.81 2 4
7 13 25.56 18 15.09 385 105 3.31 / 485.91 2 3
8 8 0.24 165 15.06 335 832 4.14 / 486.74 2 10
Average= 3.80
(KJ/cycle)

Cycle 126 GMT 1/ 2/2022 11:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 35 15.02 481 253 0.25 / 478.75 2 2
2 12 1174.24 4 15.24 1962 120 0.37 / 478.87 2 3
3 7 2002.40 34 14.83 2854 1439 1.81 / 480.31 3 2
4 13 1516.92 18 14.86 2325 622 2.43 / 480.94 2 3
5 13 1017.52 18 14.89 1708 458 2.89 / 481.39 2 4
6 13 358.96 18 15.02 852 230 3.12 / 481.62 2 4
7 13 20.64 18 15.09 381 103 3.23 / 481.73 2 3
8 8 -0.12 165 15.05 352 874 4.10 / 482.60 2 11
Average= 3.80
(KJ/cycle)

Cycle 125 GMT 22/ 1/2022 13: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 35 15.02 485 255 0.25 / 474.67 2 2
2 12 1178.52 4 15.24 1986 121 0.38 / 474.79 2 3
3 7 2001.60 34 14.84 2858 1442 1.82 / 476.23 3 3
4 13 1496.28 18 14.86 2291 613 2.43 / 476.85 2 3
5 13 1161.72 18 14.87 1892 506 2.94 / 477.35 2 4
6 13 318.56 18 15.04 794 215 3.15 / 477.57 2 3
7 13 13.28 18 15.11 367 100 3.25 / 477.67 2 3
8 8 0.04 165 15.07 336 835 4.09 / 478.50 2 11
Average= 3.80
(KJ/cycle)

Cycle 124 GMT 12/ 1/2022 15: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 35 15.03 479 252 0.25 / 470.67 2 2
2 12 1192.36 4 15.23 2004 122 0.37 / 470.79 2 2
3 7 2005.80 34 14.84 2856 1441 1.82 / 472.23 2 3
4 13 1515.64 18 14.86 2327 622 2.44 / 472.86 2 3
5 13 1010.36 18 14.90 1695 455 2.89 / 473.31 2 5
6 13 489.92 18 14.99 1017 274 3.17 / 473.58 2 4
7 8 0.20 165 15.07 334 831 4.00 / 474.41 2 12
Average= 3.80
(KJ/cycle)

Cycle 123 GMT 2/ 1/2022 16:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 35 15.02 478 251 0.25 / 466.72 2 2
2 12 1179.36 4 15.23 1955 119 0.37 / 466.84 2 3
3 7 2002.56 34 14.84 2850 1438 1.81 / 468.28 3 3
4 13 1510.24 18 14.87 2303 616 2.42 / 468.90 2 2
5 13 1016.92 18 14.90 1702 456 2.88 / 469.35 2 4
6 13 367.56 18 15.03 852 231 3.11 / 469.58 2 3
7 8 0.08 165 15.08 335 834 3.95 / 470.42 2 11
Average= 3.79
(KJ/cycle)

Cycle 122 GMT 23/12/2021 18:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 35 15.03 485 255 0.26 / 462.68 2 2
2 12 1177.40 4 15.23 1955 119 0.37 / 462.80 2 3
3 7 2003.60 34 14.84 2850 1438 1.81 / 464.23 3 2
4 13 1518.92 18 14.86 2320 621 2.43 / 464.85 2 3
5 13 1020.16 18 14.90 1709 458 2.89 / 465.31 2 4
6 13 356.96 18 15.03 835 226 3.12 / 465.54 2 3
7 13 17.84 18 15.11 368 100 3.22 / 465.64 2 3
8 8 0.12 165 15.07 335 833 4.05 / 466.47 2 11
Average= 3.79
(KJ/cycle)

Cycle 121 GMT 13/12/2021 20:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 35 15.03 478 251 0.25 / 458.69 2 2
2 12 1167.44 4 15.24 1948 119 0.37 / 458.81 2 2
3 7 2002.56 34 14.84 2855 1441 1.81 / 460.25 2 2
4 13 1500.52 18 14.87 2288 612 2.42 / 460.86 2 3
5 13 1003.80 18 14.91 1683 452 2.87 / 461.31 2 5
6 13 490.12 18 15.00 1018 275 3.15 / 461.59 2 4
7 8 0.16 165 15.08 336 836 3.99 / 462.42 2 11
Average= 3.79
(KJ/cycle)

Cycle 120 GMT 3/12/2021 22:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 35 15.03 481 253 0.25 / 454.74 2 2
2 12 1174.24 4 15.23 1968 120 0.37 / 454.86 2 3
3 7 2003.88 34 14.84 2853 1440 1.81 / 456.30 3 3
4 13 1510.80 18 14.87 2311 619 2.43 / 456.92 2 3
5 13 1012.24 18 14.90 1694 454 2.89 / 457.37 2 5
6 13 355.88 18 15.03 841 228 3.11 / 457.60 2 3
7 8 0.08 165 15.08 336 836 3.95 / 458.44 2 10
Average= 3.79
(KJ/cycle)

Cycle 119 GMT 24/11/2021 0:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 35 15.03 478 251 0.25 / 450.77 2 2
2 12 1176.24 4 15.24 1986 121 0.37 / 450.90 2 3
3 7 2004.96 34 14.84 2856 1441 1.81 / 452.34 3 3
4 13 1516.48 18 14.87 2321 621 2.43 / 452.96 2 3
5 13 1022.68 18 14.90 1715 460 2.89 / 453.42 2 4
6 13 360.48 18 15.03 847 229 3.12 / 453.65 2 4
7 8 0.40 165 15.08 338 841 3.96 / 454.49 2 11
Average= 3.79
(KJ/cycle)

Cycle 118 GMT 14/11/2021 1:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 35 15.03 478 251 0.25 / 446.78 2 2
2 12 1176.92 4 15.24 1952 119 0.37 / 446.90 2 3
3 7 2006.68 34 14.83 2871 1448 1.82 / 448.34 3 2
4 13 1519.60 18 14.86 2332 624 2.44 / 448.97 2 3
5 13 1006.48 18 14.91 1686 452 2.89 / 449.42 2 7
6 13 491.96 18 15.00 1021 276 3.17 / 449.70 2 4
7 8 -0.16 165 15.08 332 826 4.00 / 450.52 2 11
Average= 3.79
(KJ/cycle)

Cycle 117 GMT 4/11/2021 3:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 35 15.04 477 251 0.25 / 442.81 2 2
2 12 1171.28 4 15.24 1950 119 0.37 / 442.93 2 2
3 7 2004.28 34 14.85 2852 1440 1.81 / 444.36 2 3
4 13 1501.44 18 14.88 2290 613 2.42 / 444.98 2 4
5 13 1009.36 18 14.91 1689 453 2.88 / 445.43 2 6
6 13 483.96 18 15.00 1012 273 3.15 / 445.70 2 4
7 8 0.40 165 15.09 330 822 3.97 / 446.53 2 11
Average= 3.78
(KJ/cycle)

Cycle 116 GMT 25/10/2021 5:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 35 15.04 484 255 0.25 / 438.71 2 2
2 12 1167.16 4 15.23 1946 119 0.37 / 438.83 2 2
3 7 2007.36 34 14.84 2847 1436 1.81 / 440.27 2 2
4 13 1502.76 18 14.87 2304 617 2.43 / 440.88 2 2
5 13 1003.36 18 14.91 1681 451 2.88 / 441.34 2 5
6 13 481.64 18 15.01 1001 270 3.15 / 441.61 2 5
7 8 -0.08 165 15.08 331 824 3.97 / 442.43 2 11
8 14 -0.08 25 15.06 334 126 4.10 / 442.56 2 12
Average= 3.78
(KJ/cycle)

Cycle 115 GMT 15/10/2021 7:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 35 15.03 477 251 0.25 / 434.79 2 2
2 12 1168.84 4 15.24 1940 118 0.37 / 434.91 2 3
3 7 2001.76 34 14.85 2869 1449 1.82 / 436.35 3 2
4 13 1505.08 18 14.87 2296 615 2.43 / 436.97 2 3
5 13 997.76 18 14.91 1678 450 2.88 / 437.42 2 4
6 13 326.04 18 15.04 793 215 3.10 / 437.63 2 3
7 8 0.24 165 15.09 331 824 3.92 / 438.46 2 8
Average= 3.78
(KJ/cycle)

Cycle 114 GMT 5/10/2021 9:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 35 15.03 492 259 0.26 / 430.81 2 2
2 12 1178.00 4 15.23 1963 120 0.38 / 430.93 2 3
3 7 2002.16 34 14.85 2846 1437 1.82 / 432.37 3 3
4 13 1502.12 18 14.88 2291 614 2.43 / 432.98 2 3
5 13 998.76 18 14.92 1672 449 2.88 / 433.43 2 5
6 13 489.48 18 15.01 1014 274 3.15 / 433.70 2 6
7 8 -0.04 165 15.09 334 832 3.98 / 434.54 2 12
Average= 3.78
(KJ/cycle)

Cycle 113 GMT 25/ 9/2021 11:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 35 15.04 488 257 0.26 / 426.72 2 2
2 12 1163.52 4 15.24 1949 119 0.38 / 426.84 2 3
3 7 2002.44 34 14.85 2852 1440 1.82 / 428.28 3 2
4 13 1512.96 18 14.87 2301 616 2.43 / 428.89 2 2
5 13 993.60 18 14.92 1669 448 2.88 / 429.34 2 4
6 13 478.20 18 15.01 1002 271 3.15 / 429.61 2 5
7 13 21.88 18 15.11 381 104 3.25 / 429.72 2 3
8 8 0.16 165 15.08 336 836 4.09 / 430.55 2 11
Average= 3.78
(KJ/cycle)

Cycle 112 GMT 15/ 9/2021 13:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 35 15.03 483 254 0.25 / 422.78 2 2
2 12 1174.60 4 15.24 1948 119 0.37 / 422.90 2 2
3 7 2005.00 34 14.85 2857 1442 1.82 / 424.34 2 3
4 13 1509.00 18 14.88 2302 617 2.43 / 424.96 2 3
5 13 1009.76 18 14.92 1685 453 2.88 / 425.41 2 5
6 13 345.52 18 15.05 824 223 3.11 / 425.63 2 4
7 8 0.00 165 15.09 334 832 3.94 / 426.46 2 10
Average= 3.77
(KJ/cycle)

Cycle 111 GMT 5/ 9/2021 15:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 35 15.03 487 256 0.26 / 418.60 2 2
2 12 1167.32 4 15.24 1954 119 0.38 / 418.72 2 2
3 7 2006.20 34 14.85 2875 1452 1.83 / 420.18 2 2
4 13 1501.96 18 14.88 2291 614 2.44 / 420.79 2 3
5 13 1009.28 18 14.92 1699 456 2.90 / 421.24 2 5
6 13 353.20 18 15.04 835 226 3.12 / 421.47 2 3
7 13 13.12 18 15.12 361 98 3.22 / 421.57 2 3
8 8 0.08 165 15.08 333 829 4.05 / 422.40 2 12
9 14 0.08 25 15.06 333 125 4.18 / 422.52 3 12
Average= 3.77
(KJ/cycle)

Cycle 110 GMT 26/ 8/2021 16:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 35 15.03 487 256 0.26 / 414.57 2 2
2 12 1169.04 4 15.23 1966 120 0.38 / 414.69 2 3
3 7 2003.60 35 14.84 2857 1484 1.86 / 416.18 3 3
4 13 1487.84 18 14.88 2282 611 2.47 / 416.79 2 4
5 13 984.24 18 14.92 1662 446 2.92 / 417.24 2 5
6 13 468.12 18 15.01 995 269 3.19 / 417.50 2 5
7 8 0.08 165 15.09 339 844 4.03 / 418.35 2 9
Average= 3.77
(KJ/cycle)

Cycle 109 GMT 16/ 8/2021 18:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 35 15.04 486 256 0.26 / 410.44 2 2
2 12 1162.16 4 15.24 1949 119 0.37 / 410.55 2 2
3 7 2005.56 34 14.84 2856 1441 1.82 / 412.00 2 3
4 13 1505.60 18 14.88 2299 616 2.43 / 412.61 2 3
5 13 1011.20 18 14.92 1704 458 2.89 / 413.07 2 5
6 13 499.32 18 15.01 1035 280 3.17 / 413.35 2 3
7 8 0.92 165 15.09 338 842 4.01 / 414.19 2 10
8 14 0.92 25 15.06 338 127 4.14 / 414.32 2 17
Average= 3.77
(KJ/cycle)

Cycle 108 GMT 6/ 8/2021 20: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 35 15.04 476 251 0.25 / 406.49 2 2
2 12 1168.28 4 15.24 1945 119 0.37 / 406.61 2 3
3 7 2005.92 34 14.85 2853 1440 1.81 / 408.05 3 2
4 13 1498.88 18 14.88 2289 613 2.42 / 408.66 2 3
5 13 1008.04 18 14.91 1693 454 2.88 / 409.12 2 4
6 13 353.40 18 15.05 834 226 3.10 / 409.34 2 4
7 8 0.08 165 15.09 337 839 3.94 / 410.18 2 13
Average= 3.76
(KJ/cycle)

Cycle 107 GMT 27/ 7/2021 21:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 35 15.04 483 254 0.25 / 402.47 2 2
2 12 1162.52 4 15.25 1938 118 0.37 / 402.59 2 2
3 7 2001.56 34 14.85 2848 1438 1.81 / 404.03 2 3
4 13 1502.92 18 14.88 2290 613 2.42 / 404.64 2 3
5 13 1154.72 18 14.89 1870 501 2.92 / 405.14 2 5
6 13 457.52 18 15.03 971 263 3.19 / 405.41 2 4
7 8 0.28 165 15.10 334 832 4.02 / 406.24 2 10
Average= 3.76
(KJ/cycle)

Cycle 106 GMT 17/ 7/2021 23:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 35 15.05 484 255 0.25 / 398.51 2 2
2 12 1192.60 4 15.25 1988 121 0.38 / 398.63 2 3
3 7 2006.20 34 14.85 2859 1444 1.82 / 400.08 3 3
4 13 1515.32 18 14.88 2319 621 2.44 / 400.70 2 2
5 13 1009.32 18 14.92 1685 453 2.89 / 401.15 2 3
6 13 360.44 18 15.05 843 228 3.12 / 401.38 2 3
7 8 -0.24 165 15.09 337 839 3.96 / 402.22 2 9
Average= 3.76
(KJ/cycle)

Cycle 105 GMT 8/ 7/2021 1:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 35 15.04 479 252 0.25 / 394.41 2 2
2 12 1182.52 4 15.24 1953 119 0.37 / 394.53 2 3
3 7 2006.28 34 14.86 2858 1444 1.82 / 395.97 3 3
4 13 1499.40 18 14.88 2291 614 2.43 / 396.59 2 3
5 13 990.28 18 14.93 1673 450 2.88 / 397.04 2 5
6 13 478.92 18 15.02 999 270 3.15 / 397.31 2 5
7 8 0.00 165 15.10 331 825 3.97 / 398.13 2 12
8 14 0.00 25 15.08 333 126 4.10 / 398.26 2 10
Average= 3.76
(KJ/cycle)

Cycle 104 GMT 28/ 6/2021 3:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 35 15.03 501 264 0.26 / 390.33 2 2
2 12 1174.44 4 15.25 1963 120 0.38 / 390.45 2 3
3 7 2005.32 34 14.86 2869 1450 1.83 / 391.90 3 2
4 13 1507.68 18 14.88 2307 618 2.45 / 392.52 2 3
5 13 1009.84 18 14.93 1695 456 2.91 / 392.97 2 7
6 13 334.56 18 15.06 812 220 3.13 / 393.19 2 3
7 8 0.28 165 15.10 337 840 3.97 / 394.03 2 12
8 14 0.28 25 15.07 337 127 4.09 / 394.16 2 13
Average= 3.75
(KJ/cycle)

Cycle 103 GMT 18/ 6/2021 5: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 35 15.05 487 257 0.26 / 386.31 2 2
2 12 1152.12 4 15.25 1927 118 0.37 / 386.43 2 3
3 7 2002.76 34 14.86 2862 1446 1.82 / 387.87 3 3
4 13 1510.44 18 14.89 2296 615 2.44 / 388.49 2 3
5 13 1007.88 18 14.93 1689 454 2.89 / 388.94 2 5
6 13 490.08 18 15.02 1018 275 3.16 / 389.22 2 5
7 8 0.00 165 15.10 340 847 4.01 / 390.07 2 12
Average= 3.75
(KJ/cycle)

Cycle 102 GMT 8/ 6/2021 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 35 15.05 478 252 0.25 / 382.34 2 2
2 12 1179.00 4 15.25 1954 119 0.37 / 382.46 2 3
3 7 2001.96 34 14.86 2844 1437 1.81 / 383.89 3 3
4 13 1670.16 18 14.86 2482 664 2.47 / 384.56 2 2
5 13 982.72 18 14.94 1653 445 2.92 / 385.00 2 4
6 13 326.60 18 15.06 796 216 3.13 / 385.22 2 3
7 8 0.16 165 15.11 336 838 3.97 / 386.05 2 11
Average= 3.75
(KJ/cycle)

Cycle 101 GMT 29/ 5/2021 8:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 35 15.05 495 261 0.26 / 378.24 2 2
2 12 1159.92 4 15.25 1951 119 0.38 / 378.36 2 2
3 7 2003.40 34 14.86 2842 1436 1.82 / 379.79 2 3
4 13 1499.68 18 14.90 2288 614 2.43 / 380.41 2 3
5 13 984.32 18 14.94 1664 447 2.88 / 380.86 2 4
6 13 471.12 18 15.03 996 269 3.15 / 381.13 2 3
7 8 0.28 165 15.11 334 833 3.98 / 381.96 2 6
8 14 0.28 25 15.08 336 127 4.11 / 382.08 2 14
Average= 3.75
(KJ/cycle)

Cycle 100 GMT 19/ 5/2021 10:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 35 15.06 481 254 0.25 / 374.24 2 2
2 12 1144.80 4 15.27 1935 118 0.37 / 374.36 2 3
3 7 2002.36 34 14.86 2853 1441 1.81 / 375.80 3 3
4 13 1512.32 18 14.90 2311 620 2.43 / 376.42 2 3
5 13 902.24 18 14.95 1558 419 2.85 / 376.84 2 4
6 13 563.20 18 15.00 1114 301 3.15 / 377.14 2 5
7 8 0.24 165 15.10 336 837 3.99 / 377.98 2 12
Average= 3.74
(KJ/cycle)

Cycle 99 GMT 9/ 5/2021 12: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 34 15.06 477 244 0.24 / 370.35 2 2
2 12 1165.96 4 15.25 1955 119 0.36 / 370.47 2 3
3 7 2007.52 34 14.86 2858 1444 1.81 / 371.91 3 2
4 13 1383.48 18 14.90 2148 576 2.38 / 372.49 2 3
5 13 912.00 18 14.95 1567 422 2.81 / 372.91 2 4
6 13 415.16 18 15.04 921 249 3.05 / 373.16 2 3
7 8 0.00 165 15.11 332 828 3.88 / 373.99 2 12
Average= 3.74
(KJ/cycle)

Cycle 98 GMT 29/ 4/2021 13:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 34 15.06 481 246 0.25 / 366.34 2 2
2 10 1003.04 2 15.11 1729 52 0.30 / 366.39 2 2
3 3 955.44 -1 15.47 5 0 0.05 / 366.39 2 2
4 12 1152.36 4 15.25 1934 118 0.42 / 366.51 2 3
5 7 2001.92 34 14.87 2843 1437 1.85 / 367.95 3 3
6 13 1480.84 18 14.90 2277 611 2.46 / 368.56 2 3
7 13 988.76 18 14.94 1668 449 2.91 / 369.01 2 5
8 13 462.72 18 15.04 983 266 3.18 / 369.27 2 4
9 8 0.28 165 15.11 334 833 4.01 / 370.11 2 9
Average= 3.74
(KJ/cycle)

Cycle 97 GMT 19/ 4/2021 15:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 35 15.06 465 245 0.25 / 362.21 2 2
2 12 1172.56 4 15.26 1964 120 0.36 / 362.33 2 3
3 7 2005.96 34 14.86 2858 1444 1.81 / 363.77 3 3
4 13 1677.60 18 14.87 2505 670 2.48 / 364.44 2 4
5 13 985.96 18 14.94 1654 445 2.92 / 364.89 2 5
6 13 493.20 18 15.03 1022 276 3.20 / 365.16 2 5
7 13 30.08 18 15.14 386 105 3.31 / 365.27 2 3
8 8 0.20 165 15.10 332 827 4.13 / 366.09 2 10
Average= 3.74
(KJ/cycle)

Cycle 96 GMT 9/ 4/2021 17:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 35 15.07 472 249 0.25 / 358.32 2 2
2 12 1160.40 4 15.25 1943 119 0.37 / 358.44 2 3
3 7 2004.00 34 14.86 2866 1448 1.82 / 359.89 3 2
4 13 1374.04 18 14.91 2151 577 2.39 / 360.47 2 3
5 13 911.68 18 14.95 1569 422 2.82 / 360.89 2 4
6 13 397.60 18 15.05 897 243 3.06 / 361.13 2 4
7 8 -0.20 165 15.11 333 830 3.89 / 361.96 2 8
Average= 3.73
(KJ/cycle)

Cycle 95 GMT 30/ 3/2021 19: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 35 15.06 469 247 0.25 / 354.05 2 2
2 12 1341.64 4 15.20 2172 132 0.38 / 354.18 2 3
3 7 2004.88 34 14.86 2862 1446 1.83 / 355.63 3 2
4 13 1506.20 18 14.89 2303 617 2.44 / 356.24 2 3
5 13 1167.12 18 14.91 1884 506 2.95 / 356.75 2 5
6 13 459.68 18 15.05 978 265 3.21 / 357.01 2 3
7 13 26.44 18 15.15 384 105 3.32 / 357.12 2 3
8 8 -0.08 165 15.11 333 830 4.15 / 357.95 2 11
9 14 -0.08 25 15.09 332 125 4.27 / 358.07 4 13
Average= 3.73
(KJ/cycle)

Cycle 94 GMT 20/ 3/2021 20:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 35 15.07 465 245 0.25 / 349.91 2 2
2 12 1160.32 4 15.27 1936 118 0.36 / 350.03 2 3
3 7 2003.96 34 14.88 2852 1443 1.81 / 351.47 3 2
4 13 1662.72 18 14.88 2478 664 2.47 / 352.14 2 3
5 13 1108.68 18 14.93 1809 486 2.96 / 352.62 2 4
6 13 400.68 18 15.06 901 244 3.20 / 352.87 2 4
7 13 40.28 18 15.14 400 109 3.31 / 352.97 2 3
8 8 0.24 165 15.11 331 825 4.13 / 353.80 2 11
Average= 3.72
(KJ/cycle)

Cycle 93 GMT 10/ 3/2021 23: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 35 15.08 461 243 0.24 / 345.93 2 2
2 12 1164.40 4 15.26 1925 118 0.36 / 346.05 2 2
3 7 2002.36 34 14.87 2857 1444 1.81 / 347.49 2 2
4 13 1372.40 18 14.92 2139 574 2.38 / 348.07 2 4
5 13 1033.84 18 14.94 1720 463 2.84 / 348.53 2 4
6 13 345.84 18 15.07 818 222 3.06 / 348.75 2 3
7 13 31.92 18 15.15 381 104 3.17 / 348.86 2 3
8 8 0.32 165 15.11 324 808 3.98 / 349.67 2 13
Average= 3.72
(KJ/cycle)

Cycle 92 GMT 1/ 3/2021 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 35 15.08 461 243 0.24 / 341.87 2 2
2 12 1179.60 4 15.26 1964 120 0.36 / 341.99 2 2
3 7 2003.36 34 14.88 2850 1442 1.81 / 343.43 2 3
4 13 1506.00 18 14.90 2292 615 2.42 / 344.05 2 3
5 13 1006.20 18 14.95 1682 453 2.87 / 344.50 2 4
6 13 497.52 18 15.04 1021 276 3.15 / 344.78 2 4
7 13 28.28 18 15.15 375 102 3.25 / 344.88 2 3
8 8 -0.16 165 15.12 324 808 4.06 / 345.69 2 11
Average= 3.72
(KJ/cycle)

Cycle 91 GMT 19/ 2/2021 2:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 35 15.08 463 244 0.24 / 337.83 2 2
2 12 1172.36 4 15.28 1952 119 0.36 / 337.95 2 2
3 7 2003.68 34 14.88 2852 1443 1.81 / 339.40 2 3
4 13 1488.96 18 14.91 2279 612 2.42 / 340.01 2 3
5 13 982.08 18 14.96 1652 445 2.86 / 340.45 2 4
6 13 468.36 18 15.05 987 267 3.13 / 340.72 2 4
7 13 26.04 18 15.16 375 102 3.23 / 340.82 2 3
8 8 0.20 165 15.12 324 808 4.04 / 341.63 2 11
Average= 3.71
(KJ/cycle)

Cycle 90 GMT 9/ 2/2021 4: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 35 15.08 462 244 0.24 / 333.65 2 2
2 12 1162.24 4 15.28 1940 119 0.36 / 333.77 2 2
3 7 2004.08 34 14.88 2853 1443 1.81 / 335.21 2 3
4 13 1507.00 18 14.91 2302 618 2.42 / 335.83 2 3
5 13 1009.64 18 14.95 1679 452 2.88 / 336.28 2 6
6 13 492.36 18 15.05 1022 277 3.15 / 336.56 2 4
7 13 26.24 18 15.16 376 103 3.25 / 336.66 2 3
8 8 -0.16 165 15.13 323 806 4.06 / 337.47 2 11
9 14 -0.16 25 15.10 321 121 4.18 / 337.59 3 10
Average= 3.71
(KJ/cycle)

Cycle 89 GMT 30/ 1/2021 5:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 34 15.10 458 235 0.24 / 329.59 2 2
2 12 1160.16 4 15.27 1944 119 0.35 / 329.71 2 2
3 7 2002.00 34 14.88 2846 1440 1.79 / 331.15 2 3
4 13 1506.36 18 14.91 2288 614 2.41 / 331.76 2 3
5 13 998.72 18 14.96 1685 454 2.86 / 332.21 2 5
6 13 479.52 18 15.05 1004 272 3.13 / 332.49 2 4
7 13 53.68 18 15.15 412 112 3.25 / 332.60 2 3
8 8 -0.08 165 15.12 324 808 4.05 / 333.41 2 12
Average= 3.70
(KJ/cycle)

Cycle 88 GMT 20/ 1/2021 7:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 34 15.09 471 242 0.24 / 325.70 2 2
2 12 1162.84 4 15.27 1948 119 0.36 / 325.82 2 3
3 7 2003.48 34 14.88 2857 1445 1.81 / 327.26 3 2
4 13 1491.00 18 14.91 2280 612 2.42 / 327.88 2 3
5 13 992.16 18 14.96 1672 450 2.87 / 328.33 2 4
6 13 329.76 18 15.10 799 217 3.09 / 328.54 2 3
7 8 0.04 165 15.14 324 809 3.89 / 329.35 2 8
Average= 3.70
(KJ/cycle)

Cycle 87 GMT 10/ 1/2021 9:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 34 15.10 470 241 0.24 / 321.65 2 2
2 12 1165.64 4 15.28 1937 118 0.36 / 321.77 2 2
3 7 2003.80 34 14.88 2860 1447 1.81 / 323.21 2 3
4 13 1496.12 18 14.92 2284 613 2.42 / 323.83 2 4
5 13 989.20 18 14.97 1660 447 2.87 / 324.28 2 3
6 13 465.08 18 15.06 982 266 3.13 / 324.54 2 3
7 13 22.08 18 15.17 371 101 3.23 / 324.64 2 3
8 8 0.04 165 15.14 326 814 4.05 / 325.46 2 12
Average= 3.70
(KJ/cycle)

Cycle 86 GMT 31/12/2020 10:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 34 15.10 474 243 0.24 / 317.59 2 2
2 12 1199.60 4 15.26 1981 121 0.36 / 317.71 2 2
3 7 2005.44 34 14.89 2857 1446 1.81 / 319.16 2 3
4 13 1494.92 18 14.91 2285 613 2.42 / 319.77 2 3
5 13 995.04 18 14.96 1669 449 2.87 / 320.22 2 4
6 13 480.44 18 15.06 1006 273 3.15 / 320.49 2 3
7 13 23.44 18 15.18 370 101 3.25 / 320.59 2 3
8 8 0.08 165 15.14 326 814 4.06 / 321.41 2 13
Average= 3.69
(KJ/cycle)

Cycle 85 GMT 21/12/2020 12:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 34 15.11 464 238 0.24 / 313.54 2 2
2 12 1185.12 4 15.27 1968 120 0.36 / 313.66 2 3
3 7 2004.20 34 14.89 2857 1446 1.80 / 315.11 3 3
4 13 1490.68 18 14.92 2282 613 2.42 / 315.72 2 3
5 13 987.40 18 14.97 1663 448 2.87 / 316.17 2 3
6 13 463.76 18 15.07 981 266 3.13 / 316.43 2 4
7 13 21.76 18 15.18 369 101 3.23 / 316.53 2 3
8 8 0.04 165 15.15 325 812 4.05 / 317.35 2 10
Average= 3.69
(KJ/cycle)

Cycle 84 GMT 11/12/2020 14:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 34 15.12 468 241 0.24 / 309.64 2 2
2 12 1173.88 4 15.28 1941 119 0.36 / 309.76 2 3
3 7 2004.72 34 14.89 2860 1448 1.81 / 311.21 3 3
4 13 1495.24 18 14.92 2289 615 2.42 / 311.82 2 3
5 13 1003.64 18 14.97 1682 453 2.88 / 312.27 2 3
6 13 312.92 18 15.12 782 213 3.09 / 312.49 2 3
7 8 0.16 165 15.16 326 815 3.90 / 313.30 2 11
Average= 3.69
(KJ/cycle)

Cycle 83 GMT 1/12/2020 16:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 34 15.12 466 240 0.24 / 305.73 2 2
2 12 1167.32 4 15.29 1961 120 0.36 / 305.85 2 3
3 7 2002.16 34 14.89 2858 1447 1.81 / 307.30 3 3
4 13 1495.24 18 14.92 2285 614 2.42 / 307.91 2 3
5 13 994.24 18 14.97 1672 451 2.87 / 308.36 2 5
6 13 334.84 18 15.12 805 219 3.09 / 308.58 2 3
7 8 0.00 165 15.16 327 818 3.91 / 309.40 2 11
Average= 3.68
(KJ/cycle)

Cycle 82 GMT 21/11/2020 18: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 34 15.12 479 246 0.25 / 301.80 2 2
2 12 1169.80 4 15.28 1939 119 0.36 / 301.92 2 2
3 7 2003.32 35 14.88 2850 1484 1.85 / 303.40 2 2
4 13 1492.84 18 14.92 2280 612 2.46 / 304.01 2 2
5 13 978.96 18 14.98 1652 445 2.91 / 304.46 2 5
6 13 325.52 18 15.12 788 214 3.12 / 304.67 2 3
7 8 0.16 165 15.17 326 816 3.94 / 305.49 2 9
Average= 3.68
(KJ/cycle)

Cycle 81 GMT 11/11/2020 19:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 34 15.14 472 243 0.24 / 297.87 2 2
2 12 1162.88 4 15.29 1935 118 0.36 / 297.99 2 2
3 7 2003.36 34 14.89 2847 1441 1.80 / 299.43 2 2
4 13 1504.92 18 14.93 2293 616 2.42 / 300.05 2 3
5 13 999.96 18 14.98 1681 453 2.87 / 300.50 2 5
6 13 346.28 18 15.12 820 223 3.10 / 300.73 2 3
7 8 0.08 165 15.17 330 826 3.92 / 301.55 2 9
Average= 3.68
(KJ/cycle)

Cycle 80 GMT 1/11/2020 21:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 34 15.13 468 241 0.24 / 293.78 2 2
2 12 1158.84 4 15.29 1923 118 0.36 / 293.90 2 2
3 7 2006.56 34 14.90 2849 1443 1.80 / 295.34 2 2
4 13 1509.00 18 14.93 2298 618 2.42 / 295.96 2 3
5 13 1001.72 18 14.99 1678 453 2.87 / 296.41 2 4
6 13 478.40 18 15.10 998 271 3.14 / 296.69 2 3
7 8 0.20 165 15.19 328 822 3.97 / 297.51 2 11
8 14 0.20 25 15.17 328 124 4.09 / 297.63 2 14
Average= 3.67
(KJ/cycle)

Cycle 79 GMT 22/10/2020 23:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 34 15.16 475 245 0.24 / 289.88 2 2
2 12 1161.92 4 15.29 1937 118 0.36 / 290.00 2 3
3 7 2002.20 34 14.89 2842 1439 1.80 / 291.44 3 3
4 13 1498.48 18 14.93 2293 616 2.42 / 292.05 2 3
5 13 1000.04 18 14.98 1678 452 2.87 / 292.51 2 6
6 13 340.68 18 15.13 814 222 3.09 / 292.73 2 3
7 8 0.08 165 15.18 325 814 3.91 / 293.54 2 9
Average= 3.67
(KJ/cycle)

Cycle 78 GMT 13/10/2020 0:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 34 15.15 475 245 0.24 / 285.96 2 2
2 12 1178.88 4 15.30 1954 120 0.36 / 286.08 2 2
3 7 2004.36 34 14.90 2848 1443 1.81 / 287.53 2 2
4 13 1509.36 18 14.93 2309 621 2.43 / 288.15 2 3
5 13 998.24 18 15.00 1681 454 2.88 / 288.60 2 6
6 13 331.56 18 15.15 803 219 3.10 / 288.82 2 3
7 8 0.08 165 15.20 325 815 3.92 / 289.64 2 8
Average= 3.67
(KJ/cycle)

Cycle 77 GMT 3/10/2020 2:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 34 15.14 472 243 0.24 / 282.02 2 2
2 12 1177.88 4 15.29 1945 119 0.36 / 282.14 2 3
3 7 2005.16 34 14.90 2849 1443 1.81 / 283.58 3 3
4 13 1496.84 18 14.94 2282 614 2.42 / 284.20 2 3
5 13 998.72 18 14.99 1686 455 2.87 / 284.65 2 4
6 13 339.60 18 15.14 824 225 3.10 / 284.88 2 3
7 8 0.28 165 15.19 336 842 3.94 / 285.72 2 12
Average= 3.66
(KJ/cycle)

Cycle 76 GMT 23/ 9/2020 3:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 34 15.15 481 248 0.25 / 278.09 2 2
2 12 1159.84 4 15.30 1931 118 0.37 / 278.21 2 2
3 7 2002.64 34 14.90 2853 1445 1.81 / 279.65 2 2
4 13 1506.08 18 14.93 2298 618 2.43 / 280.27 2 3
5 13 997.36 18 14.99 1679 453 2.88 / 280.73 2 4
6 13 331.68 18 15.14 807 220 3.10 / 280.95 2 3
7 8 -0.08 165 15.19 333 835 3.94 / 281.78 2 11
Average= 3.66
(KJ/cycle)

Cycle 75 GMT 13/ 9/2020 5:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 34 15.15 477 246 0.25 / 274.18 2 2
2 12 1177.36 4 15.29 1959 120 0.37 / 274.30 2 2
3 7 2003.32 34 14.90 2852 1445 1.81 / 275.75 2 2
4 13 1364.96 18 14.96 2135 575 2.39 / 276.32 2 3
5 13 1032.52 18 14.98 1720 464 2.85 / 276.78 2 5
6 13 359.04 18 15.14 839 229 3.08 / 277.01 2 3
7 8 0.12 165 15.20 331 830 3.91 / 277.84 2 11
Average= 3.66
(KJ/cycle)

Cycle 74 GMT 3/ 9/2020 7: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 34 15.16 479 247 0.25 / 270.19 2 2
2 12 1171.76 4 15.30 1969 121 0.37 / 270.31 2 3
3 7 2005.16 35 14.90 2849 1486 1.85 / 271.80 3 2
4 13 1345.12 18 14.97 2104 567 2.42 / 272.36 2 3
5 13 1016.28 18 14.99 1700 459 2.88 / 272.82 2 3
6 13 471.68 18 15.11 995 271 3.15 / 273.09 2 3
7 8 0.32 165 15.20 336 843 3.99 / 273.94 2 10
Average= 3.65
(KJ/cycle)

Cycle 73 GMT 24/ 8/2020 8:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 34 15.17 470 242 0.24 / 266.17 2 2
2 12 1145.88 4 15.31 1938 119 0.36 / 266.29 2 3
3 7 2002.52 35 14.90 2845 1484 1.84 / 267.77 3 3
4 13 1350.76 18 14.96 2111 568 2.41 / 268.34 2 3
5 13 866.20 18 15.03 1509 408 2.82 / 268.75 2 3
6 13 367.56 18 15.14 851 232 3.05 / 268.98 2 3
7 8 -0.08 165 15.20 333 835 3.89 / 269.82 2 10
8 14 -0.08 25 15.18 330 125 4.01 / 269.94 2 12
Average= 3.65
(KJ/cycle)

Cycle 72 GMT 14/ 8/2020 10:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 34 15.17 479 247 0.25 / 262.26 2 2
2 12 1172.04 4 15.31 1975 121 0.37 / 262.39 2 2
3 7 2002.48 34 14.91 2854 1447 1.81 / 263.83 2 3
4 13 1491.88 18 14.95 2275 612 2.43 / 264.44 2 3
5 13 980.64 18 15.01 1657 448 2.87 / 264.89 2 4
6 13 326.24 18 15.17 793 217 3.09 / 265.11 2 3
7 8 0.20 165 15.21 327 821 3.91 / 265.93 2 11
Average= 3.64
(KJ/cycle)

Cycle 71 GMT 4/ 8/2020 11:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 34 15.18 468 242 0.24 / 258.30 2 2
2 12 1178.64 4 15.31 1957 120 0.36 / 258.42 2 2
3 7 2005.08 34 14.92 2848 1445 1.81 / 259.86 2 3
4 13 1487.68 18 14.96 2276 613 2.42 / 260.47 2 3
5 13 971.00 18 15.02 1644 444 2.86 / 260.92 2 4
6 13 452.48 18 15.14 964 263 3.13 / 261.18 2 4
7 8 -0.04 165 15.22 333 836 3.96 / 262.02 2 11
Average= 3.64
(KJ/cycle)

Cycle 70 GMT 25/ 7/2020 13:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 34 15.18 464 239 0.24 / 254.40 2 2
2 12 1178.92 4 15.30 1964 120 0.36 / 254.52 2 3
3 7 2001.36 35 14.91 2840 1482 1.84 / 256.00 3 3
4 13 1368.08 18 14.97 2133 575 2.42 / 256.58 2 3
5 13 884.24 18 15.04 1533 415 2.83 / 256.99 2 3
6 13 375.00 18 15.16 862 235 3.07 / 257.23 2 3
7 8 0.40 165 15.22 330 829 3.90 / 258.06 2 11
Average= 3.63
(KJ/cycle)

Cycle 69 GMT 15/ 7/2020 15: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 34 15.18 464 239 0.24 / 250.27 2 2
2 12 1184.28 4 15.31 1962 120 0.36 / 250.39 2 3
3 7 2001.28 34 14.92 2846 1444 1.80 / 251.84 3 3
4 13 1490.28 18 14.96 2278 613 2.42 / 252.45 2 3
5 13 972.60 18 15.03 1648 446 2.86 / 252.90 2 3
6 13 318.28 18 15.18 786 215 3.08 / 253.11 2 3
7 13 21.80 18 15.25 372 102 3.18 / 253.21 2 3
8 8 -0.12 165 15.22 327 821 4.00 / 254.03 2 10
9 14 -0.12 25 15.19 329 125 4.13 / 254.16 3 15
Average= 3.63
(KJ/cycle)

Cycle 68 GMT 5/ 7/2020 16:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 34 15.19 474 245 0.24 / 246.23 2 2
2 12 1165.04 4 15.31 1947 119 0.36 / 246.35 2 3
3 7 2006.36 34 14.92 2845 1443 1.81 / 247.79 3 3
4 13 1524.48 18 14.95 2307 621 2.43 / 248.41 2 3
5 13 1010.76 18 15.02 1690 457 2.88 / 248.87 2 7
6 13 350.60 18 15.18 824 225 3.11 / 249.09 2 3
7 8 -0.04 165 15.23 325 817 3.93 / 249.91 2 11
8 14 -0.04 25 15.21 324 123 4.05 / 250.03 2 11
Average= 3.62
(KJ/cycle)

Cycle 67 GMT 25/ 6/2020 18:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 34 15.19 464 240 0.24 / 242.40 2 2
2 3 1020.68 1 15.28 1776 27 0.27 / 242.43 2 3
3 12 1160.48 4 15.32 1935 119 0.39 / 242.54 2 2
4 7 1993.48 34 14.92 2840 1441 1.83 / 243.99 2 3
5 13 1358.92 18 14.98 2124 573 2.40 / 244.56 2 3
6 13 889.04 18 15.05 1540 417 2.82 / 244.98 2 4
7 13 244.96 18 15.21 684 187 3.00 / 245.16 2 3
8 8 -0.12 165 15.23 327 822 3.82 / 245.98 2 11
Average= 3.62
(KJ/cycle)

Cycle 66 GMT 15/ 6/2020 19:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 34 15.20 470 243 0.24 / 238.52 2 2
2 12 1166.16 4 15.32 1933 118 0.36 / 238.64 2 3
3 7 2003.16 34 14.92 2852 1447 1.81 / 240.09 3 3
4 13 1521.64 18 14.96 2305 621 2.43 / 240.71 2 3
5 13 884.68 18 15.05 1532 415 2.84 / 241.12 2 4
6 13 338.72 18 15.18 814 222 3.07 / 241.34 2 3
7 8 0.16 165 15.24 324 815 3.88 / 242.16 2 9
Average= 3.61
(KJ/cycle)

Cycle 65 GMT 5/ 6/2020 20:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 34 15.20 468 242 0.24 / 234.55 2 2
2 12 1170.60 4 15.31 1960 120 0.36 / 234.67 2 2
3 7 2005.80 34 14.92 2859 1450 1.81 / 236.12 2 2
4 13 1505.56 18 14.96 2303 620 2.43 / 236.74 2 3
5 13 981.80 18 15.03 1662 450 2.88 / 237.19 2 3
6 13 485.96 18 15.15 1012 276 3.16 / 237.47 2 5
7 8 0.00 165 15.24 323 812 3.97 / 238.28 2 11
Average= 3.61
(KJ/cycle)

Cycle 64 GMT 26/ 5/2020 22:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 34 15.21 455 235 0.24 / 230.69 2 2
2 12 1152.68 4 15.33 1947 119 0.35 / 230.81 2 3
3 7 2001.88 34 14.92 2852 1447 1.80 / 232.26 3 2
4 13 1374.68 18 14.98 2147 579 2.38 / 232.84 2 3
5 13 902.80 18 15.05 1558 422 2.80 / 233.26 2 3
6 13 388.48 18 15.17 880 240 3.04 / 233.50 2 3
7 8 0.04 165 15.25 321 808 3.85 / 234.31 2 10
Average= 3.60
(KJ/cycle)

Cycle 63 GMT 16/ 5/2020 23:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 34 15.21 460 238 0.24 / 226.83 2 2
2 12 1169.60 4 15.32 1963 120 0.36 / 226.95 2 2
3 7 2001.48 34 14.93 2856 1450 1.81 / 228.40 2 2
4 13 1344.68 18 15.00 2108 569 2.38 / 228.97 2 3
5 13 1021.16 18 15.03 1704 461 2.84 / 229.43 2 3
6 13 350.40 18 15.19 824 225 3.06 / 229.65 2 3
7 8 0.12 165 15.25 319 803 3.87 / 230.46 2 10
Average= 3.60
(KJ/cycle)

Cycle 62 GMT 7/ 5/2020 0:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 34 15.22 458 237 0.24 / 222.81 2 2
2 12 1171.16 4 15.32 1974 121 0.36 / 222.93 2 2
3 7 2003.32 34 14.93 2851 1447 1.81 / 224.38 2 3
4 13 1480.60 18 14.97 2266 611 2.42 / 224.99 2 3
5 13 980.00 18 15.04 1644 445 2.86 / 225.44 2 3
6 13 453.96 18 15.17 958 262 3.12 / 225.70 2 3
7 13 58.40 18 15.27 405 111 3.23 / 225.81 2 2
8 8 0.04 165 15.25 311 783 4.02 / 226.59 2 9
Average= 3.60
(KJ/cycle)

Cycle 61 GMT 27/ 4/2020 2:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 34 15.23 445 230 0.23 / 218.84 2 2
2 12 1163.40 4 15.33 1938 119 0.35 / 218.96 2 2
3 7 2003.48 35 14.93 2840 1484 1.83 / 220.44 2 3
4 13 1481.68 18 14.97 2262 610 2.44 / 221.05 2 3
5 13 964.12 18 15.05 1628 441 2.88 / 221.49 2 4
6 13 295.80 18 15.22 737 202 3.09 / 221.70 2 3
7 13 67.20 18 15.28 414 114 3.20 / 221.81 2 3
8 8 -0.04 165 15.26 304 765 3.97 / 222.58 2 8
Average= 3.59
(KJ/cycle)

Cycle 60 GMT 17/ 4/2020 4: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 34 15.23 454 235 0.24 / 214.84 2 2
2 12 1178.72 4 15.33 1944 119 0.35 / 214.96 2 3
3 7 2001.96 34 14.94 2847 1446 1.80 / 216.40 3 3
4 13 1500.76 18 14.97 2273 612 2.41 / 217.01 2 3
5 13 995.08 18 15.05 1664 451 2.86 / 217.46 2 3
6 13 463.84 18 15.18 969 265 3.13 / 217.73 2 4
7 13 57.68 18 15.28 400 110 3.24 / 217.84 2 2
8 8 0.00 165 15.26 306 770 4.01 / 218.61 2 7
Average= 3.58
(KJ/cycle)

Cycle 59 GMT 7/ 4/2020 5:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 34 15.24 453 235 0.23 / 210.81 2 2
2 3 1019.16 1 15.32 1744 27 0.26 / 210.83 2 3
3 12 1179.04 4 15.34 1957 120 0.38 / 210.95 2 2
4 7 2002.28 34 14.94 2843 1444 1.83 / 212.40 2 2
5 13 1493.12 18 14.98 2284 616 2.44 / 213.01 2 3
6 13 988.72 18 15.06 1652 448 2.89 / 213.46 2 3
7 13 459.16 18 15.18 963 263 3.15 / 213.72 2 3
8 13 63.12 18 15.28 407 112 3.26 / 213.84 2 2
9 8 0.00 165 15.27 304 766 4.03 / 214.60 2 9
Average= 3.58
(KJ/cycle)

Cycle 58 GMT 28/ 3/2020 7:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 34 15.24 450 233 0.23 / 206.73 2 2
2 12 1190.56 4 15.34 1986 122 0.36 / 206.85 2 2
3 7 2003.24 34 14.94 2840 1443 1.80 / 208.29 2 2
4 13 1499.96 18 14.99 2293 619 2.42 / 208.91 2 3
5 13 997.36 18 15.06 1666 452 2.87 / 209.36 2 4
6 13 316.08 18 15.24 765 210 3.08 / 209.57 2 3
7 13 69.68 18 15.29 417 115 3.19 / 209.69 2 2
8 8 0.20 165 15.28 305 769 3.96 / 210.46 2 10
9 14 0.20 25 15.26 303 116 4.08 / 210.57 2 9
Average= 3.57
(KJ/cycle)

Cycle 57 GMT 18/ 3/2020 8:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 34 15.25 435 226 0.23 / 202.68 2 2
2 12 1180.84 4 15.33 1964 120 0.35 / 202.80 2 3
3 7 2001.84 34 14.95 2840 1444 1.79 / 204.24 3 3
4 13 1482.04 18 14.99 2268 612 2.40 / 204.86 2 3
5 13 1135.80 18 15.03 1843 499 2.90 / 205.35 2 4
6 13 406.96 18 15.21 899 246 3.15 / 205.60 2 3
7 13 49.00 18 15.30 396 109 3.26 / 205.71 2 3
8 8 0.24 165 15.28 311 784 4.04 / 206.49 2 10
Average= 3.56
(KJ/cycle)

Cycle 56 GMT 8/ 3/2020 10:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 34 15.25 459 238 0.24 / 198.73 2 2
2 12 1184.24 4 15.34 1988 122 0.36 / 198.85 2 2
3 7 2002.72 34 14.94 2847 1446 1.81 / 200.29 2 2
4 13 1496.08 18 14.99 2293 619 2.42 / 200.91 2 3
5 13 986.04 18 15.07 1651 448 2.87 / 201.36 2 4
6 13 304.32 18 15.24 751 206 3.08 / 201.57 2 3
7 13 63.16 18 15.30 410 113 3.19 / 201.68 2 2
8 8 0.20 165 15.28 307 774 3.97 / 202.45 2 6
Average= 3.55
(KJ/cycle)

Cycle 55 GMT 27/ 2/2020 12: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 34 15.26 452 235 0.23 / 194.75 2 2
2 12 1179.68 3 15.35 1988 92 0.33 / 194.84 2 2
3 7 2006.96 35 14.94 2847 1489 1.81 / 196.33 2 2
4 13 1479.36 18 15.00 2263 611 2.43 / 196.94 2 3
5 13 980.08 18 15.07 1655 449 2.87 / 197.39 2 3
6 13 315.12 18 15.24 775 213 3.09 / 197.60 2 3
7 13 35.48 18 15.31 376 104 3.19 / 197.70 2 2
8 8 0.00 165 15.29 311 785 3.98 / 198.49 2 9
Average= 3.54
(KJ/cycle)

Cycle 54 GMT 17/ 2/2020 13:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 33 15.26 448 226 0.23 / 190.77 2 2
2 12 1167.96 3 15.34 1948 90 0.32 / 190.86 2 2
3 7 2005.00 35 14.94 2854 1492 1.81 / 192.35 2 2
4 13 1499.08 18 14.99 2287 617 2.42 / 192.97 2 3
5 13 989.64 18 15.07 1667 452 2.88 / 193.42 2 4
6 13 331.32 18 15.24 792 217 3.09 / 193.64 2 3
7 13 52.36 18 15.31 392 108 3.20 / 193.74 2 3
8 8 0.08 165 15.29 305 769 3.97 / 194.51 2 7
Average= 3.54
(KJ/cycle)

Cycle 53 GMT 7/ 2/2020 15:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 33 15.26 451 227 0.23 / 186.75 2 2
2 12 1188.44 2 15.36 2001 61 0.29 / 186.81 2 2
3 7 2007.56 39 14.93 2854 1662 1.95 / 188.48 2 3
4 13 1344.56 18 15.02 2104 569 2.52 / 189.04 2 4
5 13 852.72 18 15.11 1486 404 2.92 / 189.45 2 3
6 13 332.24 18 15.24 791 217 3.14 / 189.67 2 3
7 13 39.28 18 15.32 377 104 3.24 / 189.77 2 2
8 8 0.16 165 15.29 306 772 4.02 / 190.54 2 8
Average= 3.53
(KJ/cycle)

Cycle 52 GMT 28/ 1/2020 17:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 33 15.27 446 225 0.22 / 182.80 2 2
2 12 1174.64 2 15.36 1964 60 0.29 / 182.86 2 2
3 7 2003.28 38 14.94 2842 1613 1.90 / 184.47 2 2
4 13 1348.40 18 15.03 2118 573 2.47 / 185.04 2 3
5 13 873.88 18 15.10 1521 413 2.88 / 185.46 2 3
6 13 219.96 18 15.28 637 175 3.06 / 185.63 2 2
7 13 45.04 18 15.32 387 107 3.17 / 185.74 2 2
8 8 0.00 165 15.29 312 787 3.95 / 186.53 2 9
Average= 3.52
(KJ/cycle)

Cycle 51 GMT 18/ 1/2020 19:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 33 15.27 452 228 0.23 / 178.70 2 2
2 12 1185.12 2 15.37 1973 61 0.29 / 178.76 2 3
3 7 2008.48 38 14.94 2846 1616 1.90 / 180.37 3 2
4 13 1485.20 18 15.00 2267 612 2.52 / 180.98 2 3
5 13 816.56 18 15.13 1439 392 2.91 / 181.38 2 3
6 13 304.48 18 15.26 749 206 3.11 / 181.58 2 3
7 13 29.68 18 15.33 362 100 3.21 / 181.68 2 2
8 8 0.08 165 15.30 306 772 3.99 / 182.45 2 13
9 14 0.08 25 15.28 305 117 4.10 / 182.57 2 11
Average= 3.51
(KJ/cycle)

Cycle 50 GMT 8/ 1/2020 21: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 33 15.27 450 227 0.23 / 174.78 2 2
2 12 1168.72 2 15.36 1959 60 0.29 / 174.84 2 2
3 7 2004.32 38 14.94 2839 1612 1.90 / 176.45 2 2
4 13 1336.20 18 15.04 2093 567 2.47 / 177.02 2 4
5 13 849.52 18 15.12 1488 405 2.87 / 177.42 2 3
6 13 203.68 18 15.29 610 168 3.04 / 177.59 2 3
7 13 23.36 18 15.34 354 98 3.14 / 177.69 2 2
8 8 0.00 165 15.31 308 778 3.91 / 178.47 2 10
Average= 3.50
(KJ/cycle)

Cycle 49 GMT 29/12/2019 22:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 33 15.27 456 230 0.23 / 170.76 2 2
2 7 2009.36 39 14.95 2848 1661 1.89 / 172.42 2 2
3 13 1479.28 18 15.01 2268 613 2.50 / 173.03 2 3
4 13 961.00 18 15.10 1618 440 2.94 / 173.47 2 4
5 13 281.76 18 15.27 721 198 3.14 / 173.67 2 3
6 13 28.68 18 15.34 363 100 3.24 / 173.77 2 2
7 8 0.08 165 15.31 311 786 4.03 / 174.55 2 10
Average= 3.49
(KJ/cycle)

Cycle 48 GMT 20/12/2019 1: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 33 15.28 451 227 0.23 / 166.74 2 2
2 7 2008.28 38 14.95 2847 1617 1.84 / 168.36 2 2
3 13 1496.96 18 15.01 2288 618 2.46 / 168.98 2 3
4 13 981.84 18 15.10 1655 450 2.91 / 169.43 2 4
5 13 311.04 18 15.27 763 210 3.12 / 169.64 2 3
6 13 28.72 18 15.33 362 100 3.22 / 169.74 2 2
7 8 0.08 165 15.31 312 788 4.01 / 170.53 2 11
Average= 3.48
(KJ/cycle)

Cycle 47 GMT 10/12/2019 3:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 33 15.28 460 232 0.23 / 162.66 2 2
2 7 2003.76 39 14.96 2831 1652 1.88 / 164.31 2 3
3 13 1481.48 18 15.02 2267 613 2.50 / 164.93 2 3
4 13 969.32 18 15.10 1638 445 2.94 / 165.37 2 4
5 13 444.68 18 15.23 950 260 3.20 / 165.63 2 3
6 13 23.76 18 15.34 355 98 3.30 / 165.73 2 2
7 8 0.16 165 15.31 312 788 4.09 / 166.52 2 10
Average= 3.47
(KJ/cycle)

Cycle 46 GMT 30/11/2019 5:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 33 15.28 461 232 0.23 / 158.71 2 2
2 7 2003.12 39 14.96 2840 1657 1.89 / 160.37 2 3
3 13 1485.80 18 15.02 2266 613 2.50 / 160.98 2 3
4 13 971.16 18 15.10 1640 446 2.95 / 161.42 2 3
5 13 305.96 18 15.27 757 208 3.16 / 161.63 2 3
6 8 0.16 165 15.32 315 796 3.95 / 162.43 2 9
Average= 3.46
(KJ/cycle)

Cycle 45 GMT 20/11/2019 8: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 34 15.29 456 237 0.24 / 154.62 2 2
2 7 2011.68 38 14.96 2852 1621 1.86 / 156.24 2 2
3 13 1506.92 18 15.02 2298 621 2.48 / 156.86 2 3
4 13 999.60 18 15.10 1678 456 2.94 / 157.32 2 3
5 13 469.64 18 15.22 983 269 3.21 / 157.59 2 3
6 13 23.08 18 15.34 354 98 3.30 / 157.69 2 2
7 8 0.04 165 15.31 313 791 4.09 / 158.48 2 11
Average= 3.45
(KJ/cycle)

Cycle 44 GMT 10/11/2019 10:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 34 15.30 452 235 0.24 / 150.68 2 2
2 7 2003.16 39 14.97 2837 1656 1.89 / 152.34 2 3
3 13 1495.00 18 15.03 2284 618 2.51 / 152.95 2 3
4 13 970.24 18 15.12 1645 448 2.96 / 153.40 2 3
5 13 298.36 18 15.29 741 204 3.16 / 153.61 2 3
6 8 0.04 165 15.33 307 777 3.94 / 154.38 2 7
Average= 3.43
(KJ/cycle)

Cycle 43 GMT 31/10/2019 12:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 34 15.30 465 242 0.24 / 146.78 2 2
2 7 2005.76 38 14.97 2837 1614 1.86 / 148.40 2 2
3 13 1496.76 18 15.03 2282 617 2.47 / 149.01 2 3
4 13 981.04 18 15.12 1657 451 2.92 / 149.47 2 3
5 13 315.56 18 15.29 754 208 3.13 / 149.67 2 2
6 8 0.08 165 15.34 305 772 3.90 / 150.45 2 8
Average= 3.42
(KJ/cycle)

Cycle 42 GMT 21/10/2019 14:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 34 15.30 450 234 0.23 / 142.89 2 2
2 7 2004.32 38 14.98 2833 1613 1.85 / 144.50 2 3
3 13 1481.20 18 15.04 2264 613 2.46 / 145.12 2 3
4 13 968.80 18 15.12 1628 443 2.90 / 145.56 2 4
5 13 316.72 18 15.29 755 208 3.11 / 145.77 2 3
6 8 0.24 165 15.34 306 775 3.89 / 146.54 2 8
Average= 3.41
(KJ/cycle)

Cycle 41 GMT 11/10/2019 17: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 33 15.31 450 227 0.23 / 138.90 2 2
2 7 2005.80 38 14.98 2839 1616 1.84 / 140.51 2 2
3 13 1489.52 18 15.04 2269 614 2.46 / 141.13 2 3
4 13 989.24 18 15.13 1661 452 2.91 / 141.58 2 3
5 13 332.40 18 15.29 776 214 3.12 / 141.79 2 2
6 13 34.24 18 15.36 358 99 3.22 / 141.89 2 2
7 8 -0.12 165 15.34 302 764 3.99 / 142.66 2 10
Average= 3.40
(KJ/cycle)

Cycle 40 GMT 1/10/2019 19:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 33 15.31 456 230 0.23 / 135.00 2 2
2 7 2004.36 38 14.99 2842 1619 1.85 / 136.62 3 2
3 13 1494.56 18 15.04 2275 616 2.47 / 137.24 2 3
4 13 992.36 18 15.12 1661 452 2.92 / 137.69 2 3
5 13 319.88 18 15.30 762 210 3.13 / 137.90 2 3
6 8 0.20 165 15.35 305 772 3.90 / 138.67 2 7
Average= 3.38
(KJ/cycle)

Cycle 39 GMT 21/ 9/2019 21:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 33 15.31 444 224 0.22 / 131.05 2 2
2 7 2002.84 38 14.99 2838 1617 1.84 / 132.67 2 2
3 13 1487.96 18 15.05 2281 618 2.46 / 133.29 2 3
4 13 974.92 18 15.13 1644 448 2.91 / 133.74 2 3
5 13 444.40 18 15.26 942 259 3.17 / 134.00 2 4
6 8 0.12 165 15.35 306 775 3.94 / 134.77 2 9
Average= 3.37
(KJ/cycle)

Cycle 38 GMT 11/ 9/2019 23:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 33 15.32 454 230 0.23 / 127.18 2 2
2 7 2005.36 38 14.99 2832 1613 1.84 / 128.80 3 3
3 13 1363.88 18 15.08 2120 575 2.42 / 129.37 2 3
4 13 1039.76 18 15.12 1724 469 2.89 / 129.84 2 3
5 13 341.60 18 15.30 795 219 3.11 / 130.06 2 3
6 8 0.20 165 15.35 304 770 3.88 / 130.83 2 9
Average= 3.35
(KJ/cycle)

Cycle 37 GMT 2/ 9/2019 1:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 33 15.33 438 222 0.22 / 123.30 2 2
2 7 2004.40 38 14.99 2842 1619 1.84 / 124.91 2 3
3 13 1483.88 18 15.05 2268 614 2.45 / 125.53 2 3
4 13 972.92 18 15.14 1635 446 2.90 / 125.97 2 3
5 13 308.08 18 15.31 750 207 3.11 / 126.18 2 3
6 8 -0.08 165 15.36 305 773 3.88 / 126.95 2 10
Average= 3.34
(KJ/cycle)

Cycle 36 GMT 23/ 8/2019 4: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 33 15.32 455 230 0.23 / 119.29 2 2
2 7 2008.92 38 15.00 2844 1621 1.85 / 120.91 3 2
3 13 1472.96 18 15.06 2262 613 2.46 / 121.53 2 3
4 13 975.12 18 15.14 1642 447 2.91 / 121.98 2 3
5 13 305.20 18 15.31 747 206 3.12 / 122.18 2 3
6 8 0.36 165 15.36 306 776 3.89 / 122.96 2 11
7 14 0.36 25 15.34 304 117 4.01 / 123.07 3 11
Average= 3.33
(KJ/cycle)

Cycle 35 GMT 13/ 8/2019 6:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 33 15.32 456 231 0.23 / 115.30 2 2
2 7 2003.48 39 15.00 2836 1659 1.89 / 116.96 3 3
3 13 1487.24 18 15.06 2271 616 2.51 / 117.57 2 3
4 13 973.32 18 15.14 1645 448 2.95 / 118.02 2 3
5 13 440.44 18 15.27 940 258 3.21 / 118.28 2 3
6 8 0.08 165 15.36 309 783 4.00 / 119.06 2 9
Average= 3.31
(KJ/cycle)

Cycle 34 GMT 3/ 8/2019 8:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 32 15.33 454 223 0.22 / 111.37 2 2
2 3 1023.48 1 15.36 1778 27 0.25 / 111.40 2 2
3 7 2004.96 38 15.00 2839 1618 1.87 / 113.01 2 2
4 13 1361.40 18 15.10 2129 579 2.45 / 113.59 2 3
5 13 1033.04 18 15.13 1722 469 2.92 / 114.06 2 3
6 13 356.32 18 15.30 832 229 3.15 / 114.29 2 3
7 8 0.20 165 15.36 307 778 3.92 / 115.07 2 8
Average= 3.29
(KJ/cycle)

Cycle 33 GMT 24/ 7/2019 10:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 32 15.34 460 226 0.23 / 107.53 2 2
2 3 1018.44 1 15.39 1757 27 0.25 / 107.56 2 3
3 7 1933.48 38 15.01 2761 1575 1.83 / 109.13 3 2
4 13 1445.40 18 15.08 2219 602 2.43 / 109.73 2 3
5 13 928.92 18 15.16 1588 433 2.86 / 110.17 2 3
6 13 262.28 18 15.33 693 191 3.05 / 110.36 2 3
7 8 0.04 165 15.36 311 788 3.84 / 111.15 2 8
Average= 3.27
(KJ/cycle)

Cycle 32 GMT 14/ 7/2019 11:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 32 15.34 461 226 0.23 / 103.88 2 2
2 7 1734.12 38 15.08 2539 1455 1.68 / 105.33 2 2
3 13 1416.56 18 15.12 2186 595 2.28 / 105.93 2 4
4 13 899.60 18 15.19 1553 425 2.70 / 106.35 2 3
5 13 229.60 18 15.36 645 178 2.88 / 106.53 2 3
6 8 0.00 165 15.38 305 774 3.65 / 107.30 2 8
Average= 3.25
(KJ/cycle)

Cycle 31 GMT 4/ 7/2019 13:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 32 15.35 459 225 0.23 / 100.30 2 2
2 7 1669.64 38 15.10 2471 1418 1.64 / 101.72 2 2
3 13 1348.40 18 15.14 2109 575 2.22 / 102.29 2 3
4 13 847.88 18 15.21 1485 407 2.62 / 102.70 2 3
5 13 178.84 18 15.37 576 159 2.78 / 102.86 2 2
6 8 0.20 165 15.38 312 792 3.58 / 103.65 2 8
Average= 3.24
(KJ/cycle)

Cycle 30 GMT 24/ 6/2019 15:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 32 15.35 457 224 0.22 / 96.72 2 2
2 7 1517.84 38 15.16 2288 1318 1.54 / 98.04 2 2
3 13 1371.76 18 15.16 2133 582 2.12 / 98.62 2 3
4 13 876.56 18 15.23 1515 415 2.54 / 99.03 2 3
5 13 184.36 18 15.39 580 161 2.70 / 99.19 2 2
6 13 18.56 18 15.42 343 95 2.80 / 99.29 2 2
7 8 0.16 165 15.39 309 785 3.58 / 100.07 2 9
Average= 3.23
(KJ/cycle)

Cycle 29 GMT 14/ 6/2019 17:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 32 15.36 452 222 0.22 / 93.18 2 2
2 7 1609.72 38 15.12 2394 1375 1.60 / 94.55 2 2
3 13 1314.00 18 15.15 2057 561 2.16 / 95.11 2 3
4 13 816.12 18 15.23 1444 396 2.55 / 95.51 2 3
5 13 292.80 18 15.35 736 203 2.76 / 95.71 2 3
6 8 0.16 165 15.39 307 780 3.54 / 96.49 2 7
Average= 3.22
(KJ/cycle)

Cycle 28 GMT 4/ 6/2019 19:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 32 15.37 457 225 0.22 / 89.56 2 2
2 7 1479.36 38 15.18 2237 1290 1.52 / 90.85 2 2
3 13 1330.60 18 15.18 2070 566 2.08 / 91.42 2 2
4 13 829.84 18 15.25 1457 400 2.48 / 91.82 2 3
5 13 171.52 18 15.40 561 156 2.64 / 91.97 2 2
6 13 21.84 18 15.43 346 96 2.73 / 92.07 2 2
7 8 0.12 165 15.40 303 770 3.50 / 92.84 2 7
8 14 0.12 25 15.38 302 116 3.62 / 92.96 3 14
Average= 3.21
(KJ/cycle)

Cycle 27 GMT 25/ 5/2019 22: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.48 32 15.37 448 220 0.22 / 86.13 2 2
2 7 1456.76 38 15.19 2212 1277 1.50 / 87.40 2 2
3 13 1312.84 18 15.19 2055 562 2.06 / 87.97 2 2
4 13 807.08 18 15.26 1430 393 2.45 / 88.36 2 3
5 13 286.40 18 15.37 726 201 2.65 / 88.56 2 2
6 8 0.08 165 15.41 306 778 3.43 / 89.34 2 7
Average= 3.19
(KJ/cycle)

Cycle 26 GMT 16/ 5/2019 0:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 32 15.37 451 222 0.22 / 82.62 2 2
2 7 1462.80 39 15.18 2219 1314 1.54 / 83.93 2 2
3 13 1316.72 18 15.19 2062 564 2.10 / 84.49 2 2
4 13 806.32 18 15.26 1430 393 2.49 / 84.89 2 3
5 13 154.28 18 15.41 535 148 2.64 / 85.04 2 2
6 13 33.80 18 15.43 362 101 2.74 / 85.14 2 2
7 8 0.24 165 15.41 303 770 3.51 / 85.91 2 6
Average= 3.18
(KJ/cycle)

Cycle 25 GMT 6/ 5/2019 2:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 31 15.37 453 216 0.22 / 79.32 2 2
2 7 1433.52 38 15.20 2183 1261 1.48 / 80.58 2 2
3 13 1292.20 18 15.20 2030 555 2.03 / 81.13 2 2
4 13 637.84 18 15.31 1212 334 2.37 / 81.47 2 3
5 13 160.36 18 15.41 544 151 2.52 / 81.62 2 2
6 8 0.08 165 15.41 306 778 3.30 / 82.40 2 9
Average= 3.17
(KJ/cycle)

Cycle 24 GMT 26/ 4/2019 4:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 32 15.37 455 224 0.22 / 75.88 2 2
2 7 1392.88 38 15.21 2137 1235 1.46 / 77.12 2 2
3 13 1257.96 18 15.21 1991 545 2.00 / 77.66 2 2
4 13 745.64 18 15.29 1349 371 2.38 / 78.03 2 3
5 13 215.64 18 15.41 629 174 2.55 / 78.21 2 2
6 13 43.44 18 15.44 380 106 2.66 / 78.31 2 2
7 8 0.04 165 15.41 309 786 3.44 / 79.10 2 7
Average= 3.16
(KJ/cycle)

Cycle 23 GMT 16/ 4/2019 7:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 32 15.38 444 219 0.22 / 72.39 2 2
2 7 1395.64 39 15.21 2140 1269 1.49 / 73.66 2 2
3 13 1261.60 18 15.21 1999 547 2.04 / 74.21 2 2
4 13 787.08 18 15.28 1406 387 2.42 / 74.59 2 3
5 13 257.96 18 15.39 688 191 2.61 / 74.78 2 3
6 13 23.96 18 15.44 352 98 2.71 / 74.88 2 2
7 8 0.00 165 15.41 306 778 3.49 / 75.66 2 9
Average= 3.15
(KJ/cycle)

Cycle 22 GMT 6/ 4/2019 9:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 32 15.38 451 222 0.22 / 69.00 2 2
2 7 1386.16 38 15.21 2132 1232 1.45 / 70.24 2 2
3 13 1251.80 18 15.22 1985 544 2.00 / 70.78 2 2
4 13 763.36 18 15.29 1373 378 2.38 / 71.16 2 3
5 13 150.20 18 15.42 527 146 2.52 / 71.30 2 2
6 13 35.16 18 15.45 364 101 2.62 / 71.41 2 2
7 8 0.04 165 15.42 301 766 3.39 / 72.17 2 10
Average= 3.14
(KJ/cycle)

Cycle 21 GMT 27/ 3/2019 12:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 31 15.38 446 213 0.21 / 65.59 2 2
2 7 1368.96 38 15.23 2109 1221 1.43 / 66.81 2 2
3 13 1231.56 18 15.23 1960 537 1.97 / 67.34 2 2
4 13 749.68 18 15.30 1354 373 2.34 / 67.72 2 2
5 13 239.12 18 15.41 655 182 2.53 / 67.90 2 2
6 13 44.36 18 15.44 379 105 2.63 / 68.00 2 2
7 8 0.08 165 15.42 306 779 3.41 / 68.78 2 8
Average= 3.13
(KJ/cycle)

Cycle 20 GMT 17/ 3/2019 14:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 31 15.39 428 204 0.20 / 62.16 2 2
2 7 1396.24 38 15.22 2146 1241 1.45 / 63.40 2 2
3 13 1255.00 18 15.23 1994 547 1.99 / 63.95 2 2
4 13 746.40 18 15.30 1351 372 2.36 / 64.32 2 3
5 13 221.56 18 15.41 630 175 2.54 / 64.50 2 2
6 13 39.64 18 15.45 371 103 2.64 / 64.60 2 2
7 8 0.08 165 15.42 304 773 3.42 / 65.37 2 8
Average= 3.11
(KJ/cycle)

Cycle 19 GMT 7/ 3/2019 15: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.28 31 15.39 449 214 0.21 / 58.77 2 2
2 7 1360.92 38 15.24 2099 1216 1.43 / 59.98 2 2
3 13 1231.64 18 15.24 1963 538 1.97 / 60.52 2 2
4 13 748.04 18 15.31 1351 372 2.34 / 60.90 2 2
5 13 237.04 18 15.41 654 181 2.52 / 61.08 2 2
6 13 54.80 18 15.45 394 110 2.63 / 61.19 2 2
7 8 0.04 165 15.43 303 771 3.40 / 61.96 2 7
Average= 3.10
(KJ/cycle)

Cycle 18 GMT 25/ 2/2019 15:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 31 15.40 444 212 0.21 / 55.48 2 2
2 7 1296.96 38 15.27 2019 1172 1.38 / 56.65 2 2
3 13 1175.56 18 15.26 1885 518 1.90 / 57.17 2 2
4 13 692.96 18 15.33 1280 353 2.25 / 57.52 2 2
5 13 174.60 18 15.44 564 157 2.41 / 57.67 2 2
6 13 39.32 18 15.46 370 103 2.51 / 57.78 2 2
7 8 0.12 165 15.43 305 777 3.29 / 58.55 2 8
Average= 3.08
(KJ/cycle)

Cycle 17 GMT 15/ 2/2019 16: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.80 31 15.41 449 214 0.21 / 52.24 2 2
2 7 1176.08 38 15.31 1869 1087 1.30 / 53.33 2 2
3 13 1070.00 18 15.30 1756 484 1.79 / 53.81 2 2
4 13 622.64 18 15.36 1179 326 2.11 / 54.14 2 2
5 13 144.04 18 15.45 517 144 2.26 / 54.28 2 2
6 13 36.04 18 15.47 363 101 2.36 / 54.38 2 2
7 8 0.00 165 15.44 301 767 3.12 / 55.15 2 8
8 14 0.00 25 15.42 301 116 3.24 / 55.26 2 9
Average= 3.07
(KJ/cycle)

Cycle 16 GMT 5/ 2/2019 16:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 31 15.41 442 211 0.21 / 49.10 2 2
2 7 1132.88 38 15.34 1810 1055 1.27 / 50.15 2 2
3 13 1056.12 18 15.32 1730 477 1.74 / 50.63 2 2
4 13 733.80 18 15.35 1323 366 2.11 / 50.99 2 2
5 13 203.16 18 15.45 595 165 2.27 / 51.16 2 2
6 13 41.12 18 15.48 364 101 2.38 / 51.26 2 2
7 8 0.08 165 15.45 300 765 3.14 / 52.02 2 11
Average= 3.06
(KJ/cycle)

Cycle 15 GMT 26/ 1/2019 17:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 31 15.42 435 208 0.21 / 46.01 2 2
2 7 1095.04 38 15.36 1763 1029 1.24 / 47.04 2 2
3 13 1006.52 18 15.34 1666 460 1.70 / 47.50 2 2
4 13 708.40 18 15.36 1291 357 2.05 / 47.85 2 2
5 13 210.52 18 15.46 603 168 2.22 / 48.02 2 2
6 13 41.40 18 15.48 365 102 2.32 / 48.12 2 2
7 8 0.04 165 15.46 298 760 3.08 / 48.88 2 6
Average= 3.06
(KJ/cycle)

Cycle 14 GMT 16/ 1/2019 18:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.64 31 15.42 453 217 0.22 / 42.94 2 2
2 7 1094.80 38 15.36 1763 1029 1.25 / 43.96 2 2
3 13 1012.64 18 15.34 1675 463 1.71 / 44.43 2 2
4 13 709.20 18 15.37 1288 356 2.06 / 44.78 2 2
5 13 191.12 18 15.47 575 160 2.22 / 44.94 2 2
6 13 43.00 18 15.49 365 102 2.33 / 45.05 2 2
7 8 0.12 165 15.46 296 755 3.08 / 45.80 2 9
Average= 3.05
(KJ/cycle)

Cycle 13 GMT 6/ 1/2019 19:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 31 15.42 450 215 0.22 / 39.85 2 2
2 7 1096.16 38 15.36 1767 1031 1.25 / 40.88 2 2
3 13 1009.16 18 15.34 1671 461 1.71 / 41.34 2 2
4 13 713.64 18 15.36 1296 358 2.07 / 41.70 2 2
5 13 198.48 18 15.47 586 163 2.23 / 41.86 2 2
6 13 39.64 18 15.49 361 101 2.33 / 41.96 2 2
7 8 0.08 165 15.46 297 758 3.09 / 42.72 2 7
Average= 3.05
(KJ/cycle)

Cycle 12 GMT 27/12/2018 20:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.36 30 15.42 456 211 0.21 / 36.76 2 2
2 7 1106.60 38 15.36 1784 1041 1.25 / 37.80 2 2
3 13 1015.80 18 15.34 1680 464 1.72 / 38.27 2 2
4 13 700.96 18 15.37 1279 354 2.07 / 38.62 2 2
5 13 181.12 18 15.47 561 156 2.23 / 38.78 2 2
6 13 40.04 18 15.49 360 100 2.33 / 38.88 2 2
7 8 0.08 165 15.46 295 753 3.08 / 39.63 2 10
Average= 3.05
(KJ/cycle)

Cycle 11 GMT 17/12/2018 21:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 30 15.43 428 198 0.20 / 33.65 2 2
2 7 1119.16 38 15.35 1800 1050 1.25 / 34.70 2 2
3 13 1027.24 18 15.34 1701 470 1.72 / 35.17 2 2
4 13 712.20 18 15.37 1297 359 2.08 / 35.53 2 2
5 13 207.96 18 15.47 601 167 2.24 / 35.69 2 2
6 13 42.80 18 15.49 366 102 2.35 / 35.79 2 2
7 8 0.04 165 15.46 297 758 3.10 / 36.55 2 7
Average= 3.05
(KJ/cycle)

Cycle 10 GMT 7/12/2018 22: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 30 15.42 455 210 0.21 / 30.46 2 2
2 7 1097.44 38 15.36 1777 1037 1.25 / 31.49 2 2
3 13 1004.20 18 15.35 1673 462 1.71 / 31.96 2 2
4 13 703.28 18 15.37 1287 356 2.07 / 32.31 2 2
5 13 185.20 18 15.47 571 159 2.22 / 32.47 2 2
6 13 44.20 18 15.49 370 103 2.33 / 32.57 2 2
7 8 0.12 165 15.47 298 761 3.09 / 33.33 2 10
8 14 0.12 25 15.45 297 115 3.20 / 33.45 2 11
Average= 3.04
(KJ/cycle)

Cycle 9 GMT 27/11/2018 22:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 30 15.43 456 211 0.21 / 27.35 2 2
2 7 1090.48 38 15.36 1771 1034 1.24 / 28.38 2 2
3 13 998.36 18 15.35 1670 461 1.71 / 28.84 2 2
4 13 690.20 18 15.37 1276 353 2.06 / 29.20 2 3
5 13 179.96 18 15.47 577 161 2.22 / 29.36 2 2
6 13 18.08 18 15.50 345 96 2.32 / 29.45 2 2
7 8 0.00 165 15.47 310 791 3.11 / 30.25 2 11
Average= 3.02
(KJ/cycle)

Cycle 8 GMT 17/11/2018 23:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 30 15.43 457 212 0.21 / 24.32 2 2
2 7 1100.92 38 15.36 1787 1043 1.25 / 25.36 2 2
3 13 1008.36 18 15.35 1682 465 1.72 / 25.83 2 2
4 13 694.08 18 15.38 1280 354 2.07 / 26.18 2 2
5 13 164.24 18 15.48 557 155 2.23 / 26.34 2 2
6 8 0.16 165 15.47 314 802 3.03 / 27.14 2 9
Average= 3.02
(KJ/cycle)

Cycle 7 GMT 8/11/2018 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 30 15.41 467 216 0.22 / 21.31 2 2
2 7 1108.92 38 15.36 1797 1049 1.26 / 22.36 2 2
3 13 1011.36 18 15.35 1685 466 1.73 / 22.82 2 2
4 13 685.00 18 15.38 1274 353 2.08 / 23.17 2 3
5 13 86.28 18 15.49 448 125 2.21 / 23.30 2 2
6 8 0.04 165 15.47 317 809 3.02 / 24.11 2 8
Average= 3.01
(KJ/cycle)

Cycle 6 GMT 29/10/2018 1:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 30 15.41 464 215 0.21 / 18.07 2 2
2 3 1022.16 1 15.41 1777 27 0.24 / 18.10 2 2
3 7 1260.80 39 15.30 1983 1183 1.43 / 19.29 2 2
4 13 1132.68 18 15.30 1841 507 1.93 / 19.79 2 2
5 13 640.16 18 15.37 1222 338 2.27 / 20.13 2 3
6 13 144.68 18 15.46 534 149 2.42 / 20.28 2 2
7 8 0.00 165 15.46 318 811 3.23 / 21.09 2 7
Average= 3.01
(KJ/cycle)

Cycle 5 GMT 19/10/2018 2:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 28 15.41 461 199 0.20 / 14.70 2 2
2 10 1010.64 2 15.37 1711 53 0.25 / 14.75 2 2
3 7 1344.44 38 15.28 2081 1208 1.46 / 15.96 2 2
4 13 1207.24 18 15.28 1933 532 1.99 / 16.49 2 2
5 13 857.96 18 15.31 1498 413 2.40 / 16.90 2 3
6 13 161.92 18 15.46 554 154 2.56 / 17.06 2 2
7 8 0.04 165 15.46 315 804 3.36 / 17.86 2 9
Average= 2.98
(KJ/cycle)

Cycle 4 GMT 9/10/2018 3:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 30 15.41 458 212 0.21 / 11.57 2 2
2 7 1272.20 38 15.27 1984 1151 1.36 / 12.73 2 2
3 13 1151.04 18 15.27 1849 508 1.87 / 13.23 2 2
4 13 662.32 18 15.34 1233 340 2.21 / 13.57 2 2
5 13 166.84 18 15.44 545 151 2.36 / 13.73 2 2
6 8 0.04 165 15.45 303 772 3.14 / 14.50 2 4
Average= 2.90
(KJ/cycle)

Cycle 3 GMT 8/10/2018 2:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 29 15.40 464 207 0.21 / 8.45 2 2
2 7 1266.84 38 15.28 1967 1142 1.35 / 9.60 2 2
3 13 1138.92 18 15.28 1834 504 1.85 / 10.10 2 2
4 13 658.76 18 15.34 1231 340 2.19 / 10.44 2 2
5 13 158.44 18 15.45 533 148 2.34 / 10.59 2 2
6 8 0.12 165 15.45 304 775 3.12 / 11.36 2 7
Average= 2.84
(KJ/cycle)

Cycle 2 GMT 7/10/2018 2:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 28 15.41 463 200 0.20 / 5.20 2 2
2 3 1053.32 1 15.40 1793 28 0.23 / 5.22 2 2
3 7 1280.76 39 15.27 1992 1186 1.41 / 6.41 2 2
4 13 1153.36 18 15.28 1852 509 1.92 / 6.92 2 2
5 13 813.24 18 15.31 1433 395 2.32 / 7.31 2 3
6 13 146.84 18 15.45 521 145 2.46 / 7.46 2 2
7 8 0.12 165 15.45 309 788 3.25 / 8.25 2 5
Average= 2.75
(KJ/cycle)

Cycle 1 GMT 6/10/2018 1:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 23 15.60 422 151 0.15 / 1.76 2 2
2 10 1013.48 4 15.42 1684 104 0.26 / 1.86 2 2
3 3 1104.76 3 15.39 1866 86 0.34 / 1.95 2 2
4 7 1019.20 74 15.27 1651 1866 2.21 / 3.81 2 2
5 8 0.00 240 15.45 319 1183 3.39 / 5.00 2 14
Average= 2.50
(KJ/cycle)

Cycle 0 GMT 5/10/2018 15:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 82.28 22 15.74 389 135 0.13 / 0.13 2 2
2 7 96.16 74 15.71 402 467 0.60 / 0.60 2 2
3 8 0.28 240 15.66 267 1003 1.61 / 1.61 2 9
Average= 1.61
(KJ/cycle)