SIO Argo Site:
Pump Diagnostics Page   



Serial= 8559 WMO= 5905241

Return

←PreviousNext→

Bug in float firmware: Transmitted values shaded red are not valid


Cycle 249 GMT 21/ 3/2024 19:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 20 14.99 2 1 0.00 / 815.56 3 3
2 7 1921.68 29 14.26 2894 1197 1.20 / 816.75 3 3
3 13 1422.12 18 14.34 2323 600 1.80 / 817.35 3 3
4 13 916.20 18 14.50 1640 428 2.23 / 817.78 3 3
5 13 225.92 18 14.82 685 183 2.41 / 817.96 3 3
6 13 22.40 18 14.93 372 100 2.51 / 818.06 3 3
7 8 0.00 180 14.89 335 898 3.41 / 818.96 3 3
Average= 3.28
(KJ/cycle)

Cycle 248 GMT 11/ 3/2024 19:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 20 15.00 4 1 0.00 / 812.12 3 3
2 7 1922.72 29 14.24 2929 1210 1.21 / 813.33 3 3
3 13 1426.16 18 14.34 2326 600 1.81 / 813.93 3 3
4 13 910.20 18 14.49 1658 432 2.24 / 814.36 3 3
5 13 228.16 18 14.82 697 186 2.43 / 814.54 3 3
6 13 20.80 18 14.93 375 101 2.53 / 814.64 3 3
7 8 -0.08 180 14.89 340 911 3.44 / 815.56 3 3
Average= 3.28
(KJ/cycle)

Cycle 247 GMT 1/ 3/2024 18:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 20 15.00 3 1 0.00 / 808.82 3 3
2 7 1923.04 29 14.25 2897 1197 1.20 / 810.02 3 3
3 13 1430.04 18 14.34 2321 599 1.80 / 810.62 3 3
4 13 931.56 18 14.49 1655 432 2.23 / 811.05 3 3
5 13 235.16 18 14.81 701 187 2.42 / 811.23 3 3
6 8 0.08 180 14.90 328 880 3.30 / 812.11 3 3
Average= 3.27
(KJ/cycle)

Cycle 246 GMT 20/ 2/2024 18:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 20 14.99 2 1 0.00 / 805.48 3 3
2 7 1921.40 29 14.26 2909 1203 1.20 / 806.68 3 3
3 13 1417.88 18 14.35 2320 599 1.80 / 807.28 3 3
4 13 908.44 18 14.49 1653 431 2.23 / 807.71 3 3
5 13 220.68 18 14.82 695 185 2.42 / 807.89 3 3
6 8 0.20 180 14.89 345 925 3.34 / 808.82 3 3
Average= 3.27
(KJ/cycle)

Cycle 245 GMT 10/ 2/2024 17:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 20 14.99 3 1 0.00 / 802.05 3 3
2 7 1922.28 29 14.25 2913 1204 1.20 / 803.25 3 3
3 13 1420.60 18 14.35 2316 598 1.80 / 803.85 3 3
4 13 921.56 18 14.50 1645 429 2.23 / 804.28 3 3
5 13 225.96 18 14.82 699 186 2.42 / 804.47 3 3
6 13 20.36 18 14.93 373 100 2.52 / 804.57 3 3
7 8 0.08 180 14.89 338 906 3.42 / 805.48 3 3
Average= 3.27
(KJ/cycle)

Cycle 244 GMT 31/ 1/2024 17: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 20 14.99 3 1 0.00 / 798.64 3 3
2 7 1922.24 29 14.26 2897 1198 1.20 / 799.84 3 3
3 13 1424.20 18 14.35 2321 600 1.80 / 800.44 3 3
4 13 912.88 18 14.49 1652 431 2.23 / 800.87 3 3
5 13 233.96 18 14.82 700 187 2.42 / 801.06 3 3
6 13 18.92 18 14.93 368 99 2.51 / 801.16 3 3
7 8 -0.20 180 14.89 334 895 3.41 / 802.05 3 3
Average= 3.27
(KJ/cycle)

Cycle 243 GMT 21/ 1/2024 16:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 20 15.00 3 1 0.00 / 795.19 3 3
2 7 1921.00 30 14.24 2918 1247 1.25 / 796.44 3 3
3 13 1422.72 18 14.34 2318 598 1.85 / 797.04 3 3
4 13 904.64 18 14.50 1632 426 2.27 / 797.47 3 3
5 13 215.64 18 14.83 675 180 2.45 / 797.65 3 3
6 13 19.80 18 14.93 371 100 2.55 / 797.74 3 3
7 8 -0.08 180 14.89 334 895 3.45 / 798.64 3 3
Average= 3.27
(KJ/cycle)

Cycle 242 GMT 11/ 1/2024 16: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 20 15.00 3 1 0.00 / 791.90 3 3
2 7 1919.56 29 14.25 2914 1204 1.21 / 793.11 3 3
3 13 1421.48 18 14.35 2312 597 1.80 / 793.71 3 3
4 13 908.76 18 14.50 1625 424 2.23 / 794.13 3 3
5 13 227.36 18 14.83 686 183 2.41 / 794.31 3 3
6 8 0.12 180 14.91 328 880 3.29 / 795.19 3 3
Average= 3.27
(KJ/cycle)

Cycle 241 GMT 1/ 1/2024 15:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 20 15.00 3 1 0.00 / 788.58 3 3
2 7 1923.92 29 14.24 2945 1216 1.22 / 789.79 3 3
3 13 1429.72 18 14.34 2331 602 1.82 / 790.39 3 3
4 13 905.96 18 14.51 1619 423 2.24 / 790.82 3 3
5 13 223.84 18 14.83 682 182 2.42 / 791.00 3 3
6 8 0.48 180 14.90 337 904 3.33 / 791.90 3 3
Average= 3.27
(KJ/cycle)

Cycle 240 GMT 22/12/2023 15: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 20 14.99 3 1 0.00 / 785.26 3 3
2 7 1923.04 29 14.26 2895 1197 1.20 / 786.46 3 3
3 13 1426.48 18 14.35 2317 598 1.80 / 787.06 3 3
4 13 911.12 18 14.51 1625 424 2.22 / 787.48 3 3
5 13 222.96 18 14.83 691 184 2.41 / 787.67 3 3
6 8 0.00 180 14.90 339 909 3.31 / 788.58 3 3
Average= 3.27
(KJ/cycle)

Cycle 239 GMT 12/12/2023 14:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 20 15.00 3 1 0.00 / 781.78 3 3
2 7 1922.20 29 14.25 2924 1208 1.21 / 782.99 3 3
3 13 1415.36 18 14.35 2319 599 1.81 / 783.59 3 3
4 13 906.44 18 14.51 1645 430 2.24 / 784.02 3 3
5 13 359.76 18 14.74 885 235 2.47 / 784.26 3 3
6 13 27.72 18 14.93 382 103 2.58 / 784.36 3 3
7 8 0.04 180 14.89 337 903 3.48 / 785.26 3 3
Average= 3.27
(KJ/cycle)

Cycle 238 GMT 2/12/2023 14:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 20 15.00 2 1 0.00 / 778.47 3 3
2 7 1921.92 29 14.27 2894 1198 1.20 / 779.66 3 3
3 13 1425.76 18 14.35 2333 603 1.80 / 780.27 3 3
4 13 910.80 18 14.51 1634 427 2.23 / 780.69 3 3
5 13 225.28 18 14.83 682 182 2.41 / 780.88 3 3
6 8 0.20 180 14.90 338 907 3.32 / 781.78 3 3
Average= 3.27
(KJ/cycle)

Cycle 237 GMT 22/11/2023 13:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 20 15.00 3 1 0.00 / 775.13 3 3
2 7 1921.48 29 14.26 2918 1207 1.21 / 776.33 3 3
3 13 1421.12 18 14.36 2309 597 1.80 / 776.93 3 3
4 13 911.40 18 14.51 1646 430 2.23 / 777.36 3 3
5 13 223.76 18 14.83 697 186 2.42 / 777.55 3 3
6 8 0.16 180 14.90 343 920 3.34 / 778.47 3 3
Average= 3.27
(KJ/cycle)

Cycle 236 GMT 12/11/2023 13: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 20 15.00 3 1 0.00 / 771.79 3 3
2 7 1919.00 29 14.27 2927 1211 1.21 / 773.00 3 3
3 13 1418.92 18 14.35 2322 600 1.81 / 773.60 3 3
4 13 928.04 18 14.50 1662 434 2.25 / 774.03 3 3
5 13 248.32 18 14.82 712 190 2.44 / 774.22 3 3
6 8 0.00 180 14.91 337 904 3.34 / 775.13 3 3
Average= 3.27
(KJ/cycle)

Cycle 235 GMT 2/11/2023 12:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 20 15.00 2 1 0.00 / 768.45 3 3
2 3 1027.36 1 15.32 3 0 0.00 / 768.45 3 3
3 7 1918.96 29 14.27 2913 1205 1.21 / 769.66 3 3
4 13 1413.48 18 14.35 2309 596 1.80 / 770.26 3 3
5 13 909.24 18 14.51 1629 425 2.23 / 770.68 3 3
6 13 223.68 18 14.84 680 182 2.41 / 770.86 3 3
7 8 0.12 180 14.90 344 923 3.33 / 771.79 3 3
Average= 3.27
(KJ/cycle)

Cycle 234 GMT 23/10/2023 12: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 20 15.00 3 1 0.00 / 765.11 3 3
2 7 1920.68 29 14.27 2878 1191 1.19 / 766.30 3 3
3 13 1420.28 18 14.36 2305 596 1.79 / 766.89 3 3
4 13 904.44 18 14.51 1633 427 2.21 / 767.32 3 3
5 13 360.48 18 14.75 870 231 2.45 / 767.55 3 3
6 8 0.16 180 14.90 337 904 3.35 / 768.45 3 3
Average= 3.27
(KJ/cycle)

Cycle 233 GMT 13/10/2023 11:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 20 15.00 3 1 0.00 / 761.78 3 3
2 7 1918.84 29 14.26 2916 1206 1.21 / 762.98 3 3
3 13 1414.68 18 14.36 2309 597 1.80 / 763.58 3 3
4 13 914.44 18 14.51 1634 427 2.23 / 764.01 3 3
5 13 231.72 18 14.83 691 184 2.41 / 764.19 3 3
6 8 -0.04 180 14.90 341 915 3.33 / 765.10 3 3
Average= 3.27
(KJ/cycle)

Cycle 232 GMT 3/10/2023 11:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 19 15.01 3 1 0.00 / 758.37 3 3
2 3 1038.52 1 15.32 3 0 0.00 / 758.37 3 3
3 7 1919.20 30 14.25 2937 1256 1.26 / 759.62 3 3
4 13 1423.84 18 14.35 2328 601 1.86 / 760.22 3 3
5 13 918.80 18 14.50 1662 434 2.29 / 760.66 3 3
6 13 229.92 18 14.83 698 186 2.48 / 760.84 3 3
7 8 0.20 180 14.90 348 933 3.41 / 761.78 3 3
Average= 3.27
(KJ/cycle)

Cycle 231 GMT 23/ 9/2023 10:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 20 15.00 3 1 0.00 / 755.02 3 3
2 3 967.28 -1 15.33 0 0 0.00 / 755.02 3 3
3 7 1920.28 29 14.27 2886 1194 1.20 / 756.22 3 3
4 13 1408.40 18 14.36 2299 594 1.79 / 756.81 3 3
5 13 893.16 18 14.52 1623 424 2.21 / 757.24 3 3
6 13 213.44 18 14.84 687 184 2.40 / 757.42 3 3
7 8 0.04 180 14.90 352 944 3.34 / 758.36 3 3
Average= 3.27
(KJ/cycle)

Cycle 230 GMT 13/ 9/2023 10: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 20 15.01 3 1 0.00 / 751.61 3 3
2 7 1917.80 29 14.27 2890 1196 1.20 / 752.81 3 3
3 13 1413.04 18 14.35 2321 600 1.80 / 753.41 3 3
4 13 907.96 18 14.51 1630 426 2.22 / 753.84 3 3
5 13 224.04 18 14.84 673 180 2.40 / 754.02 3 3
6 13 18.04 18 14.95 366 98 2.50 / 754.11 3 3
7 8 0.16 180 14.90 339 909 3.41 / 755.02 3 3
Average= 3.27
(KJ/cycle)

Cycle 229 GMT 3/ 9/2023 9:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 20 15.01 3 1 0.00 / 748.28 3 3
2 7 1921.60 29 14.27 2897 1199 1.20 / 749.48 3 3
3 13 1415.64 18 14.36 2322 600 1.80 / 750.08 3 3
4 13 910.32 18 14.52 1624 424 2.22 / 750.50 3 3
5 13 230.40 18 14.84 700 187 2.41 / 750.69 3 3
6 8 0.04 180 14.91 345 926 3.34 / 751.61 3 3
Average= 3.27
(KJ/cycle)

Cycle 228 GMT 24/ 8/2023 9: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 20 15.01 3 1 0.00 / 744.93 3 3
2 7 1917.68 29 14.27 2896 1198 1.20 / 746.13 3 3
3 13 1420.48 18 14.35 2331 602 1.80 / 746.73 3 3
4 13 914.12 18 14.51 1639 428 2.23 / 747.16 3 3
5 13 234.24 18 14.84 712 190 2.42 / 747.35 3 3
6 8 0.40 180 14.91 346 929 3.35 / 748.28 3 3
Average= 3.27
(KJ/cycle)

Cycle 227 GMT 14/ 8/2023 8:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 20 15.01 3 1 0.00 / 741.62 3 3
2 7 1916.88 29 14.28 2881 1193 1.19 / 742.81 3 3
3 13 1415.16 18 14.36 2321 600 1.79 / 743.41 3 3
4 13 910.52 18 14.52 1627 425 2.22 / 743.84 3 3
5 13 228.12 18 14.84 682 182 2.40 / 744.02 3 3
6 8 -0.12 180 14.91 339 910 3.31 / 744.93 3 3
Average= 3.27
(KJ/cycle)

Cycle 226 GMT 4/ 8/2023 8: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 20 15.01 3 1 0.00 / 738.26 3 3
2 7 1912.68 29 14.27 2907 1203 1.20 / 739.46 3 3
3 13 1563.80 18 14.33 2484 641 1.84 / 740.10 3 3
4 13 873.56 18 14.54 1585 415 2.26 / 740.52 3 3
5 13 204.56 18 14.85 667 178 2.44 / 740.69 3 3
6 8 0.32 180 14.91 344 923 3.36 / 741.62 3 3
Average= 3.27
(KJ/cycle)

Cycle 225 GMT 25/ 7/2023 7:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 19 15.01 3 1 0.00 / 734.92 3 3
2 7 1917.64 29 14.26 2914 1205 1.21 / 736.13 3 3
3 13 1418.28 18 14.36 2311 597 1.80 / 736.72 3 3
4 13 914.40 18 14.51 1653 432 2.23 / 737.15 3 3
5 13 224.08 18 14.84 686 183 2.42 / 737.34 3 3
6 8 0.04 180 14.91 342 918 3.34 / 738.26 3 3
Average= 3.27
(KJ/cycle)

Cycle 224 GMT 15/ 7/2023 7:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 20 15.02 3 1 0.00 / 731.58 3 3
2 3 971.20 -1 15.33 0 0 0.00 / 731.58 3 3
3 7 1916.48 29 14.29 2900 1202 1.20 / 732.78 3 3
4 13 1432.08 18 14.37 2326 602 1.80 / 733.38 3 3
5 13 925.60 18 14.52 1645 430 2.23 / 733.81 3 3
6 13 257.00 18 14.82 728 194 2.43 / 734.01 3 3
7 8 0.04 180 14.91 340 912 3.34 / 734.92 3 3
Average= 3.27
(KJ/cycle)

Cycle 223 GMT 5/ 7/2023 6:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.92 20 15.01 2 1 0.00 / 728.27 3 3
2 3 1023.04 1 15.33 3 0 0.00 / 728.27 3 3
3 7 1915.32 29 14.28 2891 1197 1.20 / 729.47 3 3
4 13 1415.88 18 14.37 2314 599 1.80 / 730.06 3 3
5 13 901.44 18 14.52 1620 423 2.22 / 730.49 3 3
6 13 219.80 18 14.85 667 178 2.40 / 730.67 3 3
7 8 0.12 180 14.92 340 913 3.31 / 731.58 3 3
Average= 3.27
(KJ/cycle)

Cycle 222 GMT 25/ 6/2023 6: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 20 15.01 3 1 0.00 / 724.89 3 3
2 7 1915.88 30 14.27 2904 1243 1.24 / 726.13 3 3
3 13 1424.20 18 14.36 2320 600 1.84 / 726.73 3 3
4 13 926.16 18 14.51 1667 435 2.28 / 727.16 3 3
5 13 245.84 18 14.83 713 190 2.47 / 727.35 3 3
6 8 0.20 180 14.91 340 912 3.38 / 728.27 3 3
Average= 3.27
(KJ/cycle)

Cycle 221 GMT 15/ 6/2023 5:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 20 15.02 3 1 0.00 / 721.50 3 3
2 7 1916.60 30 14.27 2920 1250 1.25 / 722.75 3 3
3 13 1419.32 18 14.36 2334 603 1.85 / 723.35 3 3
4 13 910.12 18 14.52 1624 424 2.28 / 723.78 3 3
5 13 214.52 18 14.85 689 184 2.46 / 723.96 3 3
6 8 0.04 180 14.91 344 923 3.39 / 724.89 3 3
Average= 3.27
(KJ/cycle)

Cycle 220 GMT 5/ 6/2023 5: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 20 15.01 3 1 0.00 / 718.17 3 3
2 7 1916.96 29 14.29 2913 1207 1.21 / 719.37 3 3
3 13 1437.04 18 14.36 2339 605 1.81 / 719.98 3 3
4 13 933.60 18 14.51 1677 438 2.25 / 720.42 3 3
5 13 254.36 18 14.83 719 192 2.44 / 720.61 3 3
6 8 0.24 180 14.92 332 892 3.33 / 721.50 3 3
Average= 3.26
(KJ/cycle)

Cycle 219 GMT 26/ 5/2023 4:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 20 15.02 2 1 0.00 / 714.83 3 3
2 7 1916.80 29 14.29 2885 1196 1.20 / 716.03 3 3
3 13 1419.64 18 14.36 2309 597 1.79 / 716.63 3 3
4 13 922.64 18 14.51 1663 434 2.23 / 717.06 3 3
5 13 230.96 18 14.84 700 187 2.41 / 717.25 3 3
6 8 0.04 180 14.92 342 918 3.33 / 718.17 3 3
Average= 3.26
(KJ/cycle)

Cycle 218 GMT 16/ 5/2023 3:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 20 15.02 3 1 0.00 / 711.49 3 3
2 7 1916.04 29 14.29 2907 1205 1.21 / 712.70 3 3
3 13 1437.68 18 14.36 2355 609 1.81 / 713.31 3 3
4 13 937.12 18 14.52 1661 434 2.25 / 713.74 3 3
5 13 259.76 18 14.82 738 197 2.45 / 713.94 3 3
6 8 0.08 180 14.93 333 895 3.34 / 714.83 3 3
Average= 3.26
(KJ/cycle)

Cycle 217 GMT 6/ 5/2023 3:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 20 15.03 3 1 0.00 / 708.16 3 3
2 7 1916.08 29 14.27 2918 1208 1.21 / 709.37 3 3
3 13 1418.36 18 14.37 2319 600 1.81 / 709.97 3 3
4 13 913.68 18 14.52 1634 427 2.24 / 710.40 3 3
5 13 230.68 18 14.85 695 186 2.42 / 710.58 3 3
6 8 0.16 180 14.92 338 908 3.33 / 711.49 3 3
Average= 3.26
(KJ/cycle)

Cycle 216 GMT 26/ 4/2023 2:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 19 15.01 2 1 0.00 / 704.83 3 3
2 7 1913.24 29 14.28 2909 1205 1.21 / 706.04 3 3
3 13 1417.00 18 14.37 2317 599 1.80 / 706.64 3 3
4 13 913.12 18 14.52 1643 429 2.23 / 707.07 3 3
5 13 220.76 18 14.85 685 183 2.42 / 707.25 3 3
6 8 0.28 180 14.93 340 914 3.33 / 708.16 3 3
Average= 3.26
(KJ/cycle)

Cycle 215 GMT 16/ 4/2023 2:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 19 15.01 2 1 0.00 / 701.42 3 3
2 7 1916.80 29 14.27 2918 1208 1.21 / 702.63 3 3
3 13 1415.88 18 14.37 2304 596 1.80 / 703.22 3 3
4 13 914.88 18 14.53 1638 428 2.23 / 703.65 3 3
5 13 233.76 18 14.85 693 185 2.42 / 703.84 3 3
6 13 21.56 18 14.96 375 101 2.52 / 703.94 3 3
7 8 -0.08 180 14.92 333 894 3.41 / 704.83 3 3
Average= 3.26
(KJ/cycle)

Cycle 214 GMT 6/ 4/2023 1:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 19 15.02 2 1 0.00 / 698.01 3 3
2 7 1915.04 29 14.28 2897 1200 1.20 / 699.21 3 3
3 13 1419.44 18 14.37 2328 602 1.80 / 699.81 3 3
4 13 911.20 18 14.53 1649 431 2.23 / 700.24 3 3
5 13 218.00 18 14.86 670 179 2.41 / 700.42 3 3
6 13 20.32 18 14.96 374 101 2.51 / 700.52 3 3
7 8 0.00 180 14.92 335 900 3.41 / 701.42 3 3
Average= 3.26
(KJ/cycle)

Cycle 213 GMT 27/ 3/2023 1:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 19 15.02 3 1 0.00 / 694.49 3 3
2 7 1911.00 29 14.30 2904 1204 1.21 / 695.69 3 3
3 13 1565.64 18 14.34 2497 645 1.85 / 696.34 3 3
4 13 889.56 18 14.54 1617 423 2.27 / 696.76 3 3
5 13 373.04 18 14.76 905 240 2.51 / 697.00 3 3
6 13 36.72 18 14.95 400 108 2.62 / 697.11 3 3
7 8 0.04 180 14.92 334 897 3.52 / 698.01 3 3
Average= 3.26
(KJ/cycle)

Cycle 212 GMT 17/ 3/2023 0:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 19 15.02 3 1 0.00 / 691.10 3 3
2 7 1916.20 29 14.29 2895 1200 1.20 / 692.30 3 3
3 13 1408.24 18 14.38 2295 594 1.79 / 692.89 3 3
4 13 901.84 18 14.54 1610 421 2.22 / 693.31 3 3
5 13 209.36 18 14.86 666 178 2.39 / 693.49 3 3
6 13 20.88 18 14.96 373 100 2.49 / 693.59 3 3
7 8 0.16 180 14.92 334 897 3.39 / 694.49 3 3
Average= 3.26
(KJ/cycle)

Cycle 211 GMT 7/ 3/2023 0:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 20 15.02 3 1 0.00 / 687.68 3 3
2 7 1915.60 29 14.28 2926 1212 1.21 / 688.89 3 3
3 13 1416.00 18 14.37 2312 598 1.81 / 689.49 3 3
4 13 908.80 18 14.53 1644 430 2.24 / 689.92 3 3
5 13 213.44 18 14.86 666 178 2.42 / 690.09 3 3
6 13 19.48 18 14.96 369 99 2.52 / 690.19 3 3
7 8 -0.04 180 14.92 336 902 3.42 / 691.10 3 3
Average= 3.26
(KJ/cycle)

Cycle 210 GMT 24/ 2/2023 23:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 20 15.02 3 1 0.00 / 684.19 3 3
2 7 1913.92 30 14.28 2918 1250 1.25 / 685.44 3 3
3 13 1421.48 18 14.38 2330 603 1.85 / 686.04 3 3
4 13 915.20 18 14.52 1668 436 2.29 / 686.47 3 3
5 13 224.24 18 14.85 705 188 2.48 / 686.66 3 3
6 13 21.24 18 14.96 381 103 2.58 / 686.77 3 3
7 8 0.04 180 14.93 339 911 3.49 / 687.68 3 3
Average= 3.26
(KJ/cycle)

Cycle 209 GMT 14/ 2/2023 23:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 20 15.01 3 1 0.00 / 680.77 3 3
2 7 1914.04 29 14.29 2872 1190 1.19 / 681.96 3 3
3 13 1411.44 18 14.38 2320 601 1.79 / 682.56 3 3
4 13 907.84 18 14.53 1650 432 2.22 / 682.99 3 3
5 13 228.00 18 14.85 692 185 2.41 / 683.18 3 3
6 13 19.52 18 14.96 373 100 2.51 / 683.28 3 3
7 8 -0.04 180 14.92 338 908 3.42 / 684.18 3 3
Average= 3.26
(KJ/cycle)

Cycle 208 GMT 4/ 2/2023 22:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 19 15.02 3 1 0.00 / 677.30 3 3
2 7 1915.72 29 14.29 2889 1197 1.20 / 678.50 3 3
3 13 1424.28 18 14.38 2306 597 1.79 / 679.09 3 3
4 13 907.44 18 14.54 1623 425 2.22 / 679.52 3 3
5 13 358.76 18 14.78 874 233 2.45 / 679.75 3 3
6 13 15.20 18 14.96 375 101 2.55 / 679.85 3 3
7 8 0.04 180 14.92 341 916 3.47 / 680.77 3 3
Average= 3.26
(KJ/cycle)

Cycle 207 GMT 25/ 1/2023 22:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 20 15.02 3 1 0.00 / 673.89 3 3
2 7 1913.96 29 14.29 2877 1192 1.19 / 675.08 3 3
3 13 1419.48 18 14.38 2313 599 1.79 / 675.68 3 3
4 13 909.92 18 14.53 1635 428 2.22 / 676.11 3 3
5 13 232.64 18 14.85 702 188 2.41 / 676.29 3 3
6 13 18.32 18 14.96 374 101 2.51 / 676.39 3 3
7 8 0.08 180 14.92 337 905 3.41 / 677.30 3 3
Average= 3.26
(KJ/cycle)

Cycle 206 GMT 15/ 1/2023 21:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 20 15.03 3 1 0.00 / 670.44 3 3
2 7 1911.76 30 14.30 2871 1232 1.23 / 671.67 3 3
3 13 1403.08 18 14.38 2314 599 1.83 / 672.27 3 3
4 13 897.28 18 14.55 1613 422 2.25 / 672.69 3 3
5 13 225.04 18 14.86 687 184 2.44 / 672.87 3 3
6 13 16.56 18 14.97 370 100 2.54 / 672.97 3 3
7 8 0.04 180 14.92 340 913 3.45 / 673.89 3 3
Average= 3.26
(KJ/cycle)

Cycle 205 GMT 5/ 1/2023 21:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 20 15.03 3 1 0.00 / 667.13 3 3
2 7 1912.16 29 14.30 2866 1189 1.19 / 668.31 3 3
3 13 1413.28 18 14.39 2293 594 1.78 / 668.91 3 3
4 13 898.92 18 14.54 1613 422 2.21 / 669.33 3 3
5 13 220.92 18 14.86 697 186 2.39 / 669.52 3 3
6 8 0.00 180 14.93 342 919 3.31 / 670.44 3 3
Average= 3.25
(KJ/cycle)

Cycle 204 GMT 26/12/2022 20:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 20 15.03 3 1 0.00 / 663.79 3 3
2 7 1914.24 29 14.28 2922 1210 1.21 / 665.00 3 3
3 13 1414.08 18 14.38 2312 598 1.81 / 665.60 3 3
4 13 890.52 18 14.55 1615 423 2.23 / 666.02 3 3
5 13 212.32 18 14.86 679 182 2.41 / 666.20 3 3
6 8 0.00 180 14.93 344 924 3.34 / 667.12 3 3
Average= 3.25
(KJ/cycle)

Cycle 203 GMT 16/12/2022 20:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 20 15.03 3 1 0.00 / 660.34 3 3
2 7 1914.20 29 14.29 2887 1196 1.20 / 661.53 3 3
3 13 1572.04 18 14.34 2504 646 1.84 / 662.18 3 3
4 13 1027.80 18 14.49 1807 471 2.31 / 662.65 3 3
5 13 294.52 18 14.82 786 210 2.52 / 662.86 3 3
6 8 0.00 180 14.93 344 924 3.45 / 663.79 3 3
Average= 3.25
(KJ/cycle)

Cycle 202 GMT 6/12/2022 20: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 20 15.03 3 1 0.00 / 657.00 3 3
2 7 1915.08 29 14.29 2895 1200 1.20 / 658.20 3 3
3 13 1424.96 18 14.39 2311 599 1.80 / 658.79 3 3
4 13 915.80 18 14.53 1651 432 2.23 / 659.23 3 3
5 13 225.24 18 14.86 686 183 2.41 / 659.41 3 3
6 8 0.16 180 14.93 345 927 3.34 / 660.34 3 3
Average= 3.25
(KJ/cycle)

Cycle 201 GMT 26/11/2022 19:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 20 15.03 2 1 0.00 / 653.67 3 3
2 7 1913.48 29 14.30 2874 1192 1.19 / 654.86 3 3
3 13 1420.36 18 14.39 2309 598 1.79 / 655.46 3 3
4 13 918.88 18 14.54 1648 431 2.22 / 655.89 3 3
5 13 227.84 18 14.87 687 184 2.41 / 656.07 3 3
6 8 0.16 180 14.93 343 922 3.33 / 657.00 3 3
Average= 3.25
(KJ/cycle)

Cycle 200 GMT 16/11/2022 19: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 20 15.03 3 1 0.00 / 650.34 3 3
2 7 1913.84 29 14.30 2870 1190 1.19 / 651.54 3 3
3 13 1428.16 18 14.38 2318 600 1.79 / 652.14 3 3
4 13 909.60 18 14.54 1627 426 2.22 / 652.56 3 3
5 13 238.00 18 14.86 699 187 2.40 / 652.75 3 3
6 8 0.00 180 14.94 342 920 3.32 / 653.67 3 3
Average= 3.25
(KJ/cycle)

Cycle 199 GMT 6/11/2022 18:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 19 15.04 3 1 0.00 / 646.97 3 3
2 3 1036.56 1 15.35 3 0 0.00 / 646.97 3 3
3 7 1914.48 30 14.30 2908 1248 1.25 / 648.21 3 3
4 13 1409.16 18 14.38 2315 599 1.85 / 648.81 3 3
5 13 909.64 18 14.55 1618 424 2.27 / 649.24 3 3
6 13 216.20 18 14.87 677 181 2.45 / 649.42 3 3
7 8 0.04 180 14.94 344 925 3.38 / 650.34 3 3
Average= 3.25
(KJ/cycle)

Cycle 198 GMT 27/10/2022 18:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 18 15.04 3 1 0.00 / 643.62 3 3
2 3 1052.04 1 15.35 4 0 0.00 / 643.62 3 3
3 7 1915.88 29 14.30 2897 1201 1.20 / 644.82 3 3
4 13 1426.24 18 14.38 2332 604 1.81 / 645.42 3 3
5 13 918.24 18 14.54 1632 427 2.23 / 645.85 3 3
6 13 224.40 18 14.86 688 184 2.42 / 646.03 3 3
7 8 0.12 180 14.93 347 933 3.35 / 646.97 3 3
Average= 3.25
(KJ/cycle)

Cycle 197 GMT 17/10/2022 17:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 20 15.04 3 1 0.00 / 640.31 3 3
2 3 941.00 -1 15.36 0 0 0.00 / 640.31 3 3
3 7 1906.68 29 14.31 2866 1189 1.19 / 641.50 3 3
4 13 1556.76 18 14.36 2479 641 1.83 / 642.14 3 3
5 13 857.00 18 14.58 1545 405 2.24 / 642.54 3 3
6 13 191.60 18 14.89 637 171 2.41 / 642.71 3 3
7 8 0.04 180 14.94 336 904 3.31 / 643.62 3 3
Average= 3.25
(KJ/cycle)

Cycle 196 GMT 7/10/2022 17:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 20 15.04 3 1 0.00 / 636.68 3 3
2 7 1912.12 29 14.30 2893 1200 1.20 / 637.88 3 3
3 13 1408.64 18 14.39 2296 595 1.80 / 638.47 3 3
4 13 913.28 18 14.55 1628 426 2.22 / 638.90 3 3
5 13 206.24 18 14.88 659 177 2.40 / 639.08 3 3
6 8 0.16 180 14.94 344 925 3.32 / 640.00 3 3
7 14 0.16 60 14.90 340 304 3.63 / 640.31 3 3
Average= 3.25
(KJ/cycle)

Cycle 195 GMT 27/ 9/2022 16:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 20 15.03 3 1 0.00 / 633.37 3 3
2 7 1913.56 29 14.30 2867 1189 1.19 / 634.55 3 3
3 13 1418.36 18 14.39 2309 598 1.79 / 635.15 3 3
4 13 918.48 18 14.54 1643 430 2.22 / 635.58 3 3
5 13 238.64 18 14.86 712 190 2.41 / 635.77 3 3
6 8 0.00 180 14.94 337 906 3.31 / 636.68 3 3
Average= 3.25
(KJ/cycle)

Cycle 194 GMT 17/ 9/2022 16: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 20 15.04 3 1 0.00 / 630.00 3 3
2 7 1914.04 30 14.31 2885 1239 1.24 / 631.23 3 3
3 13 1408.80 18 14.39 2301 596 1.84 / 631.83 3 3
4 13 905.84 18 14.55 1634 428 2.26 / 632.26 3 3
5 13 223.56 18 14.87 695 186 2.45 / 632.44 3 3
6 8 0.08 180 14.94 342 920 3.37 / 633.36 3 3
Average= 3.25
(KJ/cycle)

Cycle 193 GMT 7/ 9/2022 15:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 20 15.04 3 1 0.00 / 626.63 3 3
2 7 1915.04 29 14.31 2882 1196 1.20 / 627.83 3 3
3 13 1425.00 18 14.40 2305 597 1.79 / 628.43 3 3
4 13 914.64 18 14.55 1653 433 2.23 / 628.86 3 3
5 13 228.56 18 14.87 708 190 2.42 / 629.05 3 3
6 8 0.08 180 14.94 352 947 3.36 / 630.00 3 3
Average= 3.25
(KJ/cycle)

Cycle 192 GMT 28/ 8/2022 15:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 20 15.05 2 1 0.00 / 623.33 3 3
2 7 1911.96 29 14.32 2880 1196 1.20 / 624.52 3 3
3 13 1410.40 18 14.40 2296 595 1.79 / 625.12 3 3
4 13 900.68 18 14.56 1625 426 2.22 / 625.54 3 3
5 13 212.40 18 14.89 659 177 2.39 / 625.72 3 3
6 8 0.12 180 14.95 339 912 3.31 / 626.63 3 3
Average= 3.25
(KJ/cycle)

Cycle 191 GMT 18/ 8/2022 14:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 19 15.04 3 1 0.00 / 620.02 3 3
2 7 1913.40 29 14.31 2866 1189 1.19 / 621.21 3 3
3 13 1416.52 18 14.39 2317 600 1.79 / 621.81 3 3
4 13 909.28 18 14.56 1614 423 2.21 / 622.24 3 3
5 13 235.36 18 14.88 701 188 2.40 / 622.42 3 3
6 8 0.08 180 14.95 335 901 3.30 / 623.33 3 3
Average= 3.25
(KJ/cycle)

Cycle 190 GMT 8/ 8/2022 14: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 19 15.04 3 1 0.00 / 616.74 3 3
2 7 1914.88 29 14.31 2876 1194 1.19 / 617.93 3 3
3 13 1418.72 18 14.40 2298 596 1.79 / 618.53 3 3
4 13 901.68 18 14.57 1604 421 2.21 / 618.95 3 3
5 13 223.92 18 14.89 667 179 2.39 / 619.13 3 3
6 8 0.08 180 14.96 332 894 3.28 / 620.02 3 3
Average= 3.25
(KJ/cycle)

Cycle 189 GMT 29/ 7/2022 13:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 20 15.04 3 1 0.00 / 613.44 3 3
2 7 1909.68 29 14.32 2877 1195 1.20 / 614.64 3 3
3 13 1406.96 18 14.40 2292 594 1.79 / 615.23 3 3
4 13 895.00 18 14.57 1600 420 2.21 / 615.65 3 3
5 13 221.84 18 14.88 685 183 2.39 / 615.83 3 3
6 8 0.20 180 14.95 336 904 3.30 / 616.74 3 3
Average= 3.25
(KJ/cycle)

Cycle 188 GMT 19/ 7/2022 13: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 20 15.05 2 1 0.00 / 609.98 3 3
2 7 1913.00 30 14.31 2900 1245 1.25 / 611.23 3 3
3 13 1407.28 18 14.40 2296 595 1.84 / 611.82 3 3
4 13 902.24 18 14.55 1627 426 2.27 / 612.25 3 3
5 13 224.80 18 14.88 678 182 2.45 / 612.43 3 3
6 13 17.52 18 14.99 367 99 2.55 / 612.53 3 3
7 8 0.00 180 14.94 340 914 3.46 / 613.44 3 3
Average= 3.25
(KJ/cycle)

Cycle 187 GMT 9/ 7/2022 12:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 20 15.05 3 1 0.00 / 606.65 3 3
2 3 1022.52 1 15.36 4 0 0.00 / 606.65 3 3
3 7 1914.52 29 14.30 2892 1199 1.20 / 607.85 3 3
4 13 1428.28 18 14.40 2322 602 1.80 / 608.46 3 3
5 13 907.08 18 14.56 1632 428 2.23 / 608.88 3 3
6 13 225.48 18 14.88 688 184 2.41 / 609.07 3 3
7 8 0.00 180 14.95 339 912 3.33 / 609.98 3 3
Average= 3.24
(KJ/cycle)

Cycle 186 GMT 29/ 6/2022 12: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 19 15.07 3 1 0.00 / 603.34 3 3
2 7 1912.44 29 14.30 2901 1203 1.20 / 604.54 3 3
3 13 1412.48 18 14.40 2294 595 1.80 / 605.14 3 3
4 13 901.80 18 14.56 1620 425 2.22 / 605.56 3 3
5 13 216.20 18 14.88 686 184 2.41 / 605.74 3 3
6 8 0.16 180 14.96 338 910 3.32 / 606.65 3 3
Average= 3.24
(KJ/cycle)

Cycle 185 GMT 19/ 6/2022 11:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 20 15.05 3 1 0.00 / 600.03 3 3
2 7 1908.60 29 14.31 2882 1196 1.20 / 601.23 3 3
3 13 1417.48 18 14.40 2302 597 1.79 / 601.82 3 3
4 13 903.76 18 14.57 1613 423 2.22 / 602.25 3 3
5 13 216.60 18 14.89 670 180 2.40 / 602.43 3 3
6 8 0.00 180 14.96 338 910 3.31 / 603.34 3 3
Average= 3.24
(KJ/cycle)

Cycle 184 GMT 9/ 6/2022 10:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 20 15.06 3 1 0.00 / 596.61 3 3
2 7 1915.12 29 14.31 2881 1196 1.20 / 597.80 3 3
3 13 1408.28 18 14.40 2315 600 1.80 / 598.40 3 3
4 13 900.04 18 14.56 1624 426 2.22 / 598.83 3 3
5 13 211.36 18 14.89 672 180 2.40 / 599.01 3 3
6 13 41.20 18 14.98 407 110 2.51 / 599.12 3 3
7 8 0.12 180 14.95 339 912 3.42 / 600.03 3 3
Average= 3.24
(KJ/cycle)

Cycle 183 GMT 30/ 5/2022 10:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 20 15.06 3 1 0.00 / 593.31 3 3
2 7 1908.36 29 14.31 2897 1202 1.20 / 594.51 3 3
3 13 1394.52 18 14.40 2302 597 1.80 / 595.11 3 3
4 13 881.52 18 14.57 1599 419 2.22 / 595.53 3 3
5 13 209.16 18 14.90 660 177 2.40 / 595.70 3 3
6 8 0.08 180 14.97 335 903 3.30 / 596.61 3 3
Average= 3.24
(KJ/cycle)

Cycle 182 GMT 20/ 5/2022 9:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 19 15.06 3 1 0.00 / 589.98 3 3
2 7 1911.12 29 14.30 2906 1205 1.21 / 591.19 3 3
3 13 1407.52 18 14.40 2297 595 1.80 / 591.78 3 3
4 13 901.32 18 14.56 1624 426 2.23 / 592.21 3 3
5 13 220.36 18 14.88 692 185 2.41 / 592.39 3 3
6 8 0.08 180 14.96 340 916 3.33 / 593.31 3 3
Average= 3.24
(KJ/cycle)

Cycle 181 GMT 10/ 5/2022 9:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 19 15.05 3 1 0.00 / 586.68 3 3
2 7 1908.56 29 14.32 2861 1188 1.19 / 587.87 3 3
3 13 1410.56 18 14.41 2302 597 1.79 / 588.47 3 3
4 13 906.64 18 14.56 1629 427 2.21 / 588.90 3 3
5 13 228.56 18 14.88 697 187 2.40 / 589.08 3 3
6 8 0.08 180 14.97 333 897 3.30 / 589.98 3 3
Average= 3.24
(KJ/cycle)

Cycle 180 GMT 30/ 4/2022 8:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 19 15.05 3 1 0.00 / 583.25 3 3
2 7 1909.00 29 14.30 2898 1202 1.20 / 584.46 3 3
3 13 1408.92 18 14.41 2297 596 1.80 / 585.05 3 3
4 13 903.40 18 14.56 1621 425 2.22 / 585.48 3 3
5 13 231.60 18 14.88 710 190 2.41 / 585.67 3 3
6 13 19.40 18 15.00 374 101 2.51 / 585.77 3 3
7 8 -0.04 180 14.95 340 915 3.43 / 586.68 3 3
Average= 3.24
(KJ/cycle)

Cycle 179 GMT 20/ 4/2022 8:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 19 15.05 2 1 0.00 / 579.76 3 3
2 7 1907.80 30 14.32 2886 1240 1.24 / 581.00 3 3
3 13 1410.32 18 14.40 2312 599 1.84 / 581.59 3 3
4 13 904.76 18 14.56 1641 430 2.27 / 582.02 3 3
5 13 221.96 18 14.88 709 190 2.46 / 582.21 3 3
6 13 41.80 18 14.98 420 113 2.57 / 582.33 3 3
7 8 0.04 180 14.95 344 926 3.50 / 583.25 3 3
Average= 3.24
(KJ/cycle)

Cycle 178 GMT 10/ 4/2022 7:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 19 15.05 2 1 0.00 / 576.32 3 3
2 7 1910.04 29 14.31 2895 1201 1.20 / 577.52 3 3
3 13 1401.24 18 14.41 2287 593 1.80 / 578.11 3 3
4 13 892.40 18 14.57 1605 421 2.22 / 578.53 3 3
5 13 201.12 18 14.89 681 183 2.40 / 578.71 3 3
6 13 38.88 18 14.98 419 113 2.51 / 578.83 3 3
7 8 0.00 180 14.95 345 928 3.44 / 579.75 3 3
Average= 3.24
(KJ/cycle)

Cycle 177 GMT 31/ 3/2022 7:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 19 15.06 3 1 0.00 / 572.88 3 3
2 7 1909.00 30 14.32 2876 1236 1.24 / 574.12 3 3
3 13 1399.52 18 14.40 2301 596 1.83 / 574.72 3 3
4 13 881.44 18 14.58 1592 418 2.25 / 575.13 3 3
5 13 210.52 18 14.90 656 176 2.43 / 575.31 3 3
6 13 40.28 18 14.99 400 108 2.53 / 575.42 3 3
7 8 0.00 180 14.96 333 897 3.43 / 576.31 3 3
Average= 3.24
(KJ/cycle)

Cycle 176 GMT 21/ 3/2022 6:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 19 15.06 3 1 0.00 / 569.51 3 3
2 7 1907.20 29 14.32 2881 1196 1.20 / 570.71 3 3
3 13 1403.00 18 14.41 2302 597 1.79 / 571.31 3 3
4 13 884.64 18 14.58 1590 417 2.21 / 571.72 3 3
5 13 207.24 18 14.90 654 175 2.39 / 571.90 3 3
6 13 22.56 18 15.00 372 100 2.49 / 572.00 3 3
7 8 0.08 180 14.97 328 884 3.37 / 572.88 3 3
Average= 3.24
(KJ/cycle)

Cycle 175 GMT 11/ 3/2022 6:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 19 15.06 3 1 0.00 / 566.11 3 3
2 7 1909.40 29 14.31 2904 1205 1.21 / 567.31 3 3
3 13 1410.84 18 14.40 2313 600 1.81 / 567.91 3 3
4 13 900.20 18 14.56 1630 427 2.23 / 568.34 3 3
5 13 200.72 18 14.91 652 175 2.41 / 568.52 3 3
6 13 22.60 18 15.00 377 102 2.51 / 568.62 3 3
7 8 0.00 180 14.97 332 895 3.40 / 569.51 3 3
Average= 3.24
(KJ/cycle)

Cycle 174 GMT 1/ 3/2022 5:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 19 15.06 2 1 0.00 / 562.74 3 3
2 7 1904.76 29 14.32 2875 1194 1.19 / 563.93 3 3
3 13 1408.80 18 14.41 2278 591 1.79 / 564.52 3 3
4 13 893.56 18 14.58 1599 420 2.21 / 564.94 3 3
5 13 209.92 18 14.90 659 177 2.38 / 565.12 3 3
6 13 24.52 18 15.00 376 102 2.48 / 565.22 3 3
7 8 0.08 180 14.97 330 889 3.37 / 566.11 3 3
Average= 3.23
(KJ/cycle)

Cycle 173 GMT 19/ 2/2022 5:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 19 15.06 3 1 0.00 / 559.32 3 3
2 7 1905.92 29 14.31 2897 1202 1.20 / 560.53 3 3
3 13 1413.68 18 14.41 2291 594 1.80 / 561.12 3 3
4 13 900.92 18 14.57 1627 427 2.22 / 561.55 3 3
5 13 227.60 18 14.89 696 187 2.41 / 561.73 3 3
6 13 24.44 18 15.00 383 103 2.51 / 561.84 3 3
7 8 0.00 180 14.96 334 899 3.41 / 562.74 3 3
Average= 3.23
(KJ/cycle)

Cycle 172 GMT 9/ 2/2022 4:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 19 15.05 2 1 0.00 / 555.93 3 3
2 7 1905.96 29 14.31 2891 1200 1.20 / 557.13 3 3
3 13 1392.76 18 14.41 2271 589 1.79 / 557.72 3 3
4 13 885.00 18 14.58 1601 420 2.21 / 558.14 3 3
5 13 207.92 18 14.90 668 179 2.39 / 558.32 3 3
6 13 20.04 18 15.00 373 101 2.49 / 558.42 3 3
7 8 0.08 180 14.96 335 902 3.39 / 559.32 3 3
Average= 3.23
(KJ/cycle)

Cycle 171 GMT 30/ 1/2022 4:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 19 15.06 2 1 0.00 / 552.54 3 3
2 7 1906.04 29 14.32 2865 1190 1.19 / 553.73 3 3
3 13 1404.72 18 14.41 2281 592 1.78 / 554.33 3 3
4 13 893.20 18 14.58 1604 421 2.20 / 554.75 3 3
5 13 209.32 18 14.90 664 178 2.38 / 554.92 3 3
6 13 19.72 18 15.00 374 101 2.48 / 555.03 3 3
7 8 -0.04 180 14.96 336 905 3.39 / 555.93 3 3
Average= 3.23
(KJ/cycle)

Cycle 170 GMT 20/ 1/2022 3:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 20 15.06 2 1 0.00 / 549.17 3 3
2 7 1905.84 29 14.31 2889 1199 1.20 / 550.37 3 3
3 13 1407.04 18 14.42 2269 589 1.79 / 550.95 3 3
4 13 905.52 18 14.57 1619 425 2.21 / 551.38 3 3
5 13 222.84 18 14.90 672 180 2.39 / 551.56 3 3
6 13 21.16 18 15.00 365 99 2.49 / 551.66 3 3
7 8 0.04 180 14.96 329 886 3.38 / 552.54 3 3
Average= 3.23
(KJ/cycle)

Cycle 169 GMT 10/ 1/2022 3:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 20 15.06 2 1 0.00 / 545.79 3 3
2 7 1903.00 29 14.31 2879 1195 1.20 / 546.98 3 3
3 13 1403.48 18 14.42 2275 590 1.79 / 547.57 3 3
4 13 888.12 18 14.58 1598 419 2.21 / 547.99 3 3
5 13 209.48 18 14.91 657 176 2.38 / 548.17 3 3
6 13 17.24 18 15.01 364 98 2.48 / 548.27 3 3
7 8 0.08 180 14.96 334 899 3.38 / 549.17 3 3
Average= 3.23
(KJ/cycle)

Cycle 168 GMT 31/12/2021 2:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 20 15.07 3 1 0.00 / 542.34 3 3
2 7 1903.64 30 14.32 2881 1238 1.24 / 543.57 3 3
3 13 1412.12 18 14.41 2315 600 1.84 / 544.17 3 3
4 13 892.96 18 14.58 1613 423 2.26 / 544.60 3 3
5 13 217.24 18 14.91 669 180 2.44 / 544.78 3 3
6 13 17.04 18 15.01 366 99 2.54 / 544.88 3 3
7 8 0.12 180 14.96 338 910 3.45 / 545.79 3 3
Average= 3.23
(KJ/cycle)

Cycle 167 GMT 21/12/2021 2:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 20 15.06 2 1 0.00 / 539.03 3 3
2 7 1909.76 29 14.31 2910 1208 1.21 / 540.24 3 3
3 13 1418.36 18 14.41 2313 600 1.81 / 540.84 3 3
4 13 900.72 18 14.58 1618 425 2.23 / 541.26 3 3
5 13 212.08 18 14.91 666 179 2.41 / 541.44 3 3
6 8 0.16 180 14.98 332 895 3.31 / 542.34 3 3
Average= 3.23
(KJ/cycle)

Cycle 166 GMT 11/12/2021 1:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 20 15.06 2 1 0.00 / 535.63 3 3
2 7 1906.08 29 14.34 2866 1192 1.19 / 536.82 3 3
3 13 1422.96 18 14.42 2310 600 1.79 / 537.42 3 3
4 13 923.92 18 14.57 1652 433 2.23 / 537.86 3 3
5 13 396.56 18 14.79 947 252 2.48 / 538.11 3 3
6 8 0.00 180 14.97 342 922 3.40 / 539.03 3 3
Average= 3.23
(KJ/cycle)

Cycle 165 GMT 1/12/2021 1:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 20 15.07 2 1 0.00 / 532.30 3 3
2 7 1909.68 29 14.32 2880 1196 1.20 / 533.49 3 3
3 13 1415.24 18 14.41 2316 601 1.80 / 534.09 3 3
4 13 908.44 18 14.57 1645 431 2.23 / 534.52 3 3
5 13 218.56 18 14.91 680 182 2.41 / 534.71 3 3
6 8 0.36 180 14.97 343 924 3.34 / 535.63 3 3
Average= 3.23
(KJ/cycle)

Cycle 164 GMT 21/11/2021 1: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 20 15.07 2 1 0.00 / 528.97 3 3
2 7 1909.84 29 14.33 2904 1207 1.21 / 530.18 3 3
3 13 1416.60 18 14.42 2306 599 1.81 / 530.78 3 3
4 13 913.72 18 14.58 1633 429 2.23 / 531.21 3 3
5 13 229.88 18 14.91 684 184 2.42 / 531.39 3 3
6 8 0.08 180 14.98 336 906 3.32 / 532.29 3 3
Average= 3.23
(KJ/cycle)

Cycle 163 GMT 11/11/2021 0:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 20 15.08 3 1 0.00 / 525.58 3 3
2 7 1907.64 29 14.33 2882 1198 1.20 / 526.78 3 3
3 13 1564.72 18 14.37 2508 649 1.85 / 527.43 3 3
4 13 861.84 18 14.60 1574 414 2.26 / 527.84 3 3
5 13 334.64 18 14.84 841 225 2.49 / 528.07 3 3
6 8 0.00 180 14.97 336 905 3.39 / 528.97 3 3
Average= 3.23
(KJ/cycle)

Cycle 162 GMT 1/11/2021 0: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 20 15.07 2 1 0.00 / 522.12 3 3
2 7 1906.88 29 14.33 2896 1203 1.20 / 523.33 3 3
3 13 1567.04 18 14.37 2508 649 1.85 / 523.98 3 3
4 13 1020.08 18 14.54 1774 464 2.32 / 524.44 3 3
5 13 310.52 18 14.86 815 218 2.54 / 524.66 3 3
6 8 0.92 180 14.98 342 922 3.46 / 525.58 3 3
Average= 3.22
(KJ/cycle)

Cycle 161 GMT 21/10/2021 23:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 20 15.07 2 1 0.00 / 518.84 3 3
2 7 1908.80 29 14.33 2886 1199 1.20 / 520.04 3 3
3 13 1407.40 18 14.43 2279 592 1.79 / 520.63 3 3
4 13 904.32 18 14.59 1603 421 2.21 / 521.06 3 3
5 13 221.68 18 14.92 659 177 2.39 / 521.23 3 3
6 8 0.12 180 14.99 330 890 3.28 / 522.12 3 3
Average= 3.22
(KJ/cycle)

Cycle 160 GMT 11/10/2021 23:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 19 15.07 3 1 0.00 / 515.56 3 3
2 7 1907.32 29 14.33 2888 1200 1.20 / 516.76 3 3
3 13 1406.12 18 14.42 2290 594 1.80 / 517.36 3 3
4 13 898.36 18 14.59 1613 424 2.22 / 517.78 3 3
5 13 218.48 18 14.91 668 179 2.40 / 517.96 3 3
6 8 0.04 180 14.98 327 882 3.28 / 518.84 3 3
Average= 3.22
(KJ/cycle)

Cycle 159 GMT 1/10/2021 22:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 19 15.07 2 1 0.00 / 512.22 3 3
2 7 1906.60 29 14.35 2905 1209 1.21 / 513.43 3 3
3 13 1420.32 18 14.42 2301 597 1.81 / 514.03 3 3
4 13 913.48 18 14.58 1636 429 2.24 / 514.46 3 3
5 13 234.12 18 14.91 697 187 2.42 / 514.65 3 3
6 8 0.12 180 14.98 340 917 3.34 / 515.56 3 3
Average= 3.22
(KJ/cycle)

Cycle 158 GMT 21/ 9/2021 22:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 20 15.07 2 1 0.00 / 508.87 3 3
2 7 1905.00 30 14.33 2890 1242 1.24 / 510.11 3 3
3 13 1416.28 18 14.42 2302 598 1.84 / 510.71 3 3
4 13 906.12 18 14.59 1617 425 2.27 / 511.13 3 3
5 13 219.76 18 14.91 675 181 2.45 / 511.31 3 3
6 8 0.04 180 14.98 337 909 3.36 / 512.22 3 3
Average= 3.22
(KJ/cycle)

Cycle 157 GMT 11/ 9/2021 21:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 20 15.08 3 1 0.00 / 505.56 3 3
2 7 1907.36 29 14.33 2868 1192 1.19 / 506.75 3 3
3 13 1418.00 18 14.42 2294 595 1.79 / 507.35 3 3
4 13 924.44 18 14.58 1636 429 2.22 / 507.78 3 3
5 13 225.20 18 14.91 679 182 2.40 / 507.96 3 3
6 8 0.12 180 14.98 336 906 3.31 / 508.87 3 3
Average= 3.22
(KJ/cycle)

Cycle 156 GMT 1/ 9/2021 21:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 20 15.08 3 1 0.00 / 502.25 3 3
2 7 1903.64 29 14.34 2865 1191 1.19 / 503.44 3 3
3 13 1566.76 18 14.39 2470 640 1.83 / 504.08 3 3
4 13 865.80 18 14.61 1554 409 2.24 / 504.49 3 3
5 13 209.72 18 14.93 651 175 2.42 / 504.66 3 3
6 8 0.04 180 14.99 334 901 3.32 / 505.56 3 3
Average= 3.22
(KJ/cycle)

Cycle 155 GMT 22/ 8/2021 20:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 20 15.08 4 1 0.00 / 498.94 3 3
2 7 1903.72 29 14.33 2885 1199 1.20 / 500.14 3 3
3 13 1402.52 18 14.44 2274 591 1.79 / 500.73 3 3
4 13 905.32 18 14.59 1611 423 2.21 / 501.15 3 3
5 13 212.00 18 14.92 661 178 2.39 / 501.33 3 3
6 8 0.12 180 14.98 339 914 3.31 / 502.24 3 3
Average= 3.22
(KJ/cycle)

Cycle 154 GMT 12/ 8/2021 20: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 20 15.08 3 1 0.00 / 495.62 3 3
2 7 1907.16 29 14.34 2899 1206 1.21 / 496.83 3 3
3 13 1411.32 18 14.43 2309 600 1.81 / 497.42 3 3
4 13 899.76 18 14.59 1611 423 2.23 / 497.85 3 3
5 13 219.08 18 14.92 675 181 2.41 / 498.03 3 3
6 8 -0.08 180 14.99 337 909 3.32 / 498.94 3 3
Average= 3.22
(KJ/cycle)

Cycle 153 GMT 2/ 8/2021 19:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 20 15.08 3 1 0.00 / 492.31 3 3
2 7 1909.08 29 14.33 2871 1193 1.19 / 493.50 3 3
3 13 1418.16 18 14.42 2312 600 1.79 / 494.10 3 3
4 13 905.08 18 14.59 1629 428 2.22 / 494.53 3 3
5 13 209.92 18 14.93 662 178 2.40 / 494.71 3 3
6 8 0.32 180 14.98 338 911 3.31 / 495.62 3 3
Average= 3.22
(KJ/cycle)

Cycle 152 GMT 23/ 7/2021 19: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 20 15.08 2 1 0.00 / 489.02 3 3
2 7 1904.16 29 14.34 2863 1191 1.19 / 490.21 3 3
3 13 1401.84 18 14.43 2283 593 1.78 / 490.80 3 3
4 13 893.52 18 14.61 1593 419 2.20 / 491.22 3 3
5 13 220.44 18 14.92 672 180 2.38 / 491.40 3 3
6 8 0.12 180 14.99 337 909 3.29 / 492.31 3 3
Average= 3.22
(KJ/cycle)

Cycle 151 GMT 13/ 7/2021 18:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 19 15.08 3 1 0.00 / 485.65 3 3
2 3 1033.04 1 15.39 4 0 0.00 / 485.65 3 3
3 7 1910.68 29 14.34 2864 1191 1.19 / 486.85 3 3
4 13 1407.84 18 14.43 2299 597 1.79 / 487.44 3 3
5 13 894.76 18 14.60 1617 425 2.21 / 487.87 3 3
6 13 354.52 18 14.84 881 235 2.45 / 488.10 3 3
7 8 0.16 180 14.98 338 911 3.36 / 489.01 3 3
Average= 3.22
(KJ/cycle)

Cycle 150 GMT 3/ 7/2021 18:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 20 15.08 2 1 0.00 / 482.34 3 3
2 7 1906.60 29 14.34 2874 1195 1.20 / 483.54 3 3
3 13 1409.72 18 14.43 2293 596 1.79 / 484.13 3 3
4 13 899.92 18 14.60 1617 425 2.22 / 484.56 3 3
5 13 217.44 18 14.92 678 182 2.40 / 484.74 3 3
6 8 0.36 180 14.99 339 915 3.31 / 485.65 3 3
Average= 3.22
(KJ/cycle)

Cycle 149 GMT 23/ 6/2021 17:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 20 15.08 3 1 0.00 / 478.99 3 3
2 7 1905.00 30 14.33 2855 1227 1.23 / 480.22 3 3
3 13 1402.44 18 14.43 2304 598 1.83 / 480.82 3 3
4 13 895.64 18 14.60 1620 426 2.25 / 481.24 3 3
5 13 215.72 18 14.93 669 180 2.43 / 481.42 3 3
6 8 -0.08 180 14.99 340 917 3.35 / 482.34 3 3
Average= 3.22
(KJ/cycle)

Cycle 148 GMT 13/ 6/2021 17:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 20 15.08 3 1 0.00 / 475.64 3 3
2 7 1902.92 29 14.33 2890 1201 1.20 / 476.85 3 3
3 13 1409.68 18 14.43 2324 604 1.81 / 477.45 3 3
4 13 910.76 18 14.59 1646 432 2.24 / 477.88 3 3
5 13 220.16 18 14.92 686 184 2.42 / 478.07 3 3
6 8 0.20 180 14.99 343 925 3.35 / 478.99 3 3
Average= 3.21
(KJ/cycle)

Cycle 147 GMT 3/ 6/2021 16:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 20 15.08 3 1 0.00 / 472.33 3 3
2 7 1902.84 30 14.33 2883 1239 1.24 / 473.57 3 3
3 13 1410.92 18 14.43 2293 596 1.84 / 474.16 3 3
4 13 897.76 18 14.60 1595 419 2.26 / 474.58 3 3
5 13 208.48 18 14.93 650 175 2.43 / 474.76 3 3
6 8 0.20 180 15.00 329 888 3.32 / 475.64 3 3
Average= 3.21
(KJ/cycle)

Cycle 146 GMT 24/ 5/2021 16:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 20 15.08 2 1 0.00 / 469.02 3 3
2 7 1904.16 29 14.33 2890 1201 1.20 / 470.22 3 3
3 13 1409.08 18 14.43 2298 597 1.80 / 470.81 3 3
4 13 893.96 18 14.61 1603 422 2.22 / 471.24 3 3
5 13 217.88 18 14.93 683 184 2.40 / 471.42 3 3
6 8 -0.04 180 14.99 336 907 3.31 / 472.33 3 3
Average= 3.21
(KJ/cycle)

Cycle 145 GMT 14/ 5/2021 15:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 20 15.08 2 1 0.00 / 465.71 3 3
2 7 1904.80 29 14.34 2876 1196 1.20 / 466.91 3 3
3 13 1402.48 18 14.44 2285 594 1.79 / 467.50 3 3
4 13 888.88 18 14.61 1585 417 2.21 / 467.92 3 3
5 13 209.44 18 14.93 677 182 2.39 / 468.10 3 3
6 8 0.20 180 14.99 339 915 3.30 / 469.02 3 3
Average= 3.21
(KJ/cycle)

Cycle 144 GMT 4/ 5/2021 15:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 20 15.09 2 1 0.00 / 462.33 3 3
2 7 1899.88 29 14.34 2883 1199 1.20 / 463.53 3 3
3 13 1409.12 18 14.43 2304 598 1.80 / 464.13 3 3
4 13 899.16 18 14.60 1615 424 2.22 / 464.55 3 3
5 13 207.56 18 14.94 649 175 2.40 / 464.73 3 3
6 13 37.80 18 15.02 390 105 2.50 / 464.83 3 3
7 8 0.00 180 14.99 325 877 3.38 / 465.71 3 3
Average= 3.21
(KJ/cycle)

Cycle 143 GMT 24/ 4/2021 14:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 20 15.09 3 1 0.00 / 459.02 3 3
2 7 1901.96 29 14.34 2871 1194 1.19 / 460.21 3 3
3 13 1411.48 18 14.43 2301 598 1.79 / 460.81 3 3
4 13 893.00 18 14.59 1624 426 2.22 / 461.24 3 3
5 13 214.48 18 14.92 682 183 2.40 / 461.42 3 3
6 8 0.00 180 15.00 337 910 3.31 / 462.33 3 3
Average= 3.21
(KJ/cycle)

Cycle 142 GMT 14/ 4/2021 14:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 20 15.09 3 1 0.00 / 455.70 3 3
2 7 1905.52 29 14.34 2875 1196 1.20 / 456.90 3 3
3 13 1414.96 18 14.43 2314 601 1.80 / 457.50 3 3
4 13 907.44 18 14.59 1638 430 2.23 / 457.93 3 3
5 13 223.40 18 14.92 690 185 2.41 / 458.12 3 3
6 8 0.24 180 15.00 335 904 3.32 / 459.02 3 3
Average= 3.21
(KJ/cycle)

Cycle 141 GMT 4/ 4/2021 13:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 20 15.09 2 1 0.00 / 452.41 3 3
2 7 1906.16 29 14.34 2874 1195 1.20 / 453.60 3 3
3 13 1405.80 18 14.43 2310 600 1.80 / 454.20 3 3
4 13 892.12 18 14.60 1613 424 2.22 / 454.63 3 3
5 13 208.68 18 14.93 671 180 2.40 / 454.81 3 3
6 8 -0.08 180 15.00 331 894 3.29 / 455.70 3 3
Average= 3.21
(KJ/cycle)

Cycle 140 GMT 25/ 3/2021 13:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 20 15.09 2 1 0.00 / 449.14 3 3
2 7 1901.20 29 14.34 2871 1194 1.19 / 450.34 3 3
3 13 1406.16 18 14.43 2299 597 1.79 / 450.93 3 3
4 13 887.44 18 14.61 1596 420 2.21 / 451.35 3 3
5 13 205.68 18 14.94 649 175 2.39 / 451.53 3 3
6 8 0.32 180 15.00 326 880 3.27 / 452.41 3 3
Average= 3.21
(KJ/cycle)

Cycle 139 GMT 15/ 3/2021 12:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 19 15.10 2 1 0.00 / 445.62 3 3
2 7 1895.00 29 14.34 2899 1206 1.21 / 446.82 3 3
3 13 1551.24 18 14.39 2488 644 1.85 / 447.47 3 3
4 13 1005.28 18 14.55 1790 469 2.32 / 447.94 3 3
5 13 280.72 18 14.89 791 212 2.53 / 448.15 3 3
6 13 29.76 18 15.03 385 104 2.64 / 448.25 3 3
7 8 -0.16 180 15.00 330 891 3.53 / 449.14 3 3
Average= 3.21
(KJ/cycle)

Cycle 138 GMT 5/ 3/2021 12:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 19 15.08 2 1 0.00 / 442.32 3 3
2 7 1900.08 29 14.35 2858 1189 1.19 / 443.51 3 3
3 13 1404.56 18 14.44 2310 600 1.79 / 444.11 3 3
4 13 897.40 18 14.60 1635 430 2.22 / 444.54 3 3
5 13 222.12 18 14.93 694 187 2.41 / 444.73 3 3
6 8 0.20 180 15.01 329 889 3.30 / 445.62 3 3
Average= 3.21
(KJ/cycle)

Cycle 137 GMT 23/ 2/2021 12: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 19 15.08 2 1 0.00 / 438.94 3 3
2 7 1900.08 29 14.34 2891 1202 1.20 / 440.14 3 3
3 13 1407.44 18 14.44 2282 593 1.80 / 440.74 3 3
4 13 890.28 18 14.61 1614 424 2.22 / 441.16 3 3
5 13 208.44 18 14.94 657 177 2.40 / 441.34 3 3
6 13 18.68 18 15.04 368 100 2.50 / 441.44 3 3
7 8 0.00 180 15.00 327 883 3.38 / 442.32 3 3
Average= 3.21
(KJ/cycle)

Cycle 136 GMT 13/ 2/2021 11:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 19 15.08 2 1 0.00 / 435.56 3 3
2 7 1903.92 29 14.34 2870 1194 1.19 / 436.75 3 3
3 13 1411.16 18 14.44 2299 598 1.79 / 437.35 3 3
4 13 904.52 18 14.60 1615 424 2.22 / 437.78 3 3
5 13 217.84 18 14.94 661 178 2.39 / 437.95 3 3
6 13 18.84 18 15.04 362 98 2.49 / 438.05 3 3
7 8 0.04 180 14.99 330 890 3.38 / 438.94 3 3
Average= 3.20
(KJ/cycle)

Cycle 135 GMT 3/ 2/2021 11: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 19 15.09 3 1 0.00 / 432.15 3 3
2 7 1900.84 29 14.34 2864 1191 1.19 / 433.34 3 3
3 13 1398.00 18 14.44 2295 597 1.79 / 433.94 3 3
4 13 901.40 18 14.60 1616 425 2.21 / 434.36 3 3
5 13 208.64 18 14.93 670 180 2.39 / 434.54 3 3
6 13 17.48 18 15.03 373 101 2.49 / 434.64 3 3
7 8 0.08 180 14.99 339 915 3.41 / 435.56 3 3
Average= 3.20
(KJ/cycle)

Cycle 134 GMT 24/ 1/2021 10:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 19 15.08 2 1 0.00 / 428.76 3 3
2 7 1901.80 29 14.35 2871 1195 1.20 / 429.96 3 3
3 13 1398.56 18 14.44 2295 597 1.79 / 430.55 3 3
4 13 892.96 18 14.61 1601 421 2.21 / 430.98 3 3
5 13 203.64 18 14.95 642 173 2.39 / 431.15 3 3
6 13 15.92 18 15.04 360 97 2.48 / 431.25 3 3
7 8 0.08 180 15.00 335 904 3.39 / 432.15 3 3
Average= 3.20
(KJ/cycle)

Cycle 133 GMT 14/ 1/2021 10:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 20 15.08 3 1 0.00 / 425.43 3 3
2 7 1901.20 29 14.35 2855 1188 1.19 / 426.62 3 3
3 13 1403.68 18 14.44 2297 597 1.79 / 427.22 3 3
4 13 888.88 18 14.61 1594 419 2.21 / 427.64 3 3
5 13 343.64 18 14.86 850 227 2.43 / 427.87 3 3
6 8 0.08 180 15.00 332 896 3.33 / 428.76 3 3
Average= 3.20
(KJ/cycle)

Cycle 132 GMT 4/ 1/2021 9:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 19 15.10 3 1 0.00 / 422.00 3 3
2 7 1899.80 30 14.35 2869 1235 1.24 / 423.24 3 3
3 13 1388.64 18 14.44 2288 595 1.83 / 423.83 3 3
4 13 882.68 18 14.62 1594 419 2.25 / 424.25 3 3
5 13 207.12 18 14.94 662 178 2.43 / 424.43 3 3
6 13 15.88 18 15.04 367 99 2.53 / 424.53 3 3
7 8 0.12 180 14.99 336 907 3.43 / 425.43 3 3
Average= 3.20
(KJ/cycle)

Cycle 131 GMT 25/12/2020 9:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 19 15.09 2 1 0.00 / 418.71 3 3
2 7 1902.68 29 14.35 2864 1192 1.19 / 419.90 3 3
3 13 1403.04 18 14.44 2309 600 1.79 / 420.50 3 3
4 13 903.08 18 14.60 1632 429 2.22 / 420.93 3 3
5 13 217.16 18 14.94 664 179 2.40 / 421.11 3 3
6 8 0.12 180 15.01 331 894 3.29 / 422.00 3 3
Average= 3.20
(KJ/cycle)

Cycle 130 GMT 15/12/2020 8:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 19 15.09 3 1 0.00 / 415.43 3 3
2 7 1902.40 29 14.35 2844 1184 1.18 / 416.62 3 3
3 13 1394.88 18 14.44 2286 594 1.78 / 417.21 3 3
4 13 888.64 18 14.61 1613 424 2.20 / 417.63 3 3
5 13 208.84 18 14.95 655 176 2.38 / 417.81 3 3
6 8 0.16 180 15.01 331 894 3.27 / 418.71 3 3
Average= 3.20
(KJ/cycle)

Cycle 129 GMT 5/12/2020 8:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 19 15.09 4 1 0.00 / 412.14 3 3
2 7 1903.40 29 14.36 2869 1195 1.20 / 413.34 3 3
3 13 1404.56 18 14.45 2283 594 1.79 / 413.93 3 3
4 13 901.68 18 14.61 1621 426 2.22 / 414.36 3 3
5 13 213.56 18 14.95 655 176 2.39 / 414.53 3 3
6 8 0.24 180 15.01 332 897 3.29 / 415.43 3 3
Average= 3.20
(KJ/cycle)

Cycle 128 GMT 25/11/2020 7:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 19 15.09 3 1 0.00 / 408.84 3 3
2 7 1901.68 29 14.35 2868 1194 1.19 / 410.03 3 3
3 13 1413.80 18 14.44 2295 597 1.79 / 410.63 3 3
4 13 893.96 18 14.62 1599 421 2.21 / 411.05 3 3
5 13 217.04 18 14.94 673 181 2.39 / 411.23 3 3
6 8 0.04 180 15.01 337 911 3.30 / 412.14 3 3
Average= 3.19
(KJ/cycle)

Cycle 127 GMT 15/11/2020 7:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 19 15.09 3 1 0.00 / 405.56 3 3
2 7 1897.20 29 14.35 2873 1196 1.20 / 406.76 3 3
3 13 1394.16 18 14.45 2274 591 1.79 / 407.35 3 3
4 13 882.44 18 14.62 1602 422 2.21 / 407.77 3 3
5 13 200.24 18 14.95 643 173 2.38 / 407.94 3 3
6 8 0.00 180 15.01 332 897 3.28 / 408.84 3 3
Average= 3.19
(KJ/cycle)

Cycle 126 GMT 5/11/2020 7: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 19 15.10 4 1 0.00 / 402.28 3 3
2 7 1897.12 29 14.36 2856 1189 1.19 / 403.47 3 3
3 13 1400.08 18 14.45 2280 593 1.78 / 404.06 3 3
4 13 887.28 18 14.63 1584 417 2.20 / 404.48 3 3
5 13 215.68 18 14.94 663 178 2.38 / 404.66 3 3
6 8 0.12 180 15.00 334 902 3.28 / 405.56 3 3
Average= 3.19
(KJ/cycle)

Cycle 125 GMT 26/10/2020 6:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 19 15.09 3 1 0.00 / 399.01 3 3
2 7 1900.12 29 14.36 2850 1187 1.19 / 400.19 3 3
3 13 1396.60 18 14.46 2274 592 1.78 / 400.79 3 3
4 13 887.84 18 14.62 1590 418 2.20 / 401.20 3 3
5 13 202.04 18 14.96 641 173 2.37 / 401.38 3 3
6 8 0.00 180 15.01 334 902 3.27 / 402.28 3 3
Average= 3.19
(KJ/cycle)

Cycle 124 GMT 16/10/2020 6: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 19 15.09 3 1 0.00 / 395.70 3 3
2 7 1902.56 29 14.35 2856 1189 1.19 / 396.89 3 3
3 13 1399.24 18 14.45 2300 598 1.79 / 397.49 3 3
4 13 890.60 18 14.62 1603 422 2.21 / 397.91 3 3
5 13 213.84 18 14.94 659 177 2.39 / 398.09 3 3
6 8 0.28 180 15.00 341 921 3.31 / 399.01 3 3
Average= 3.19
(KJ/cycle)

Cycle 123 GMT 6/10/2020 5:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 19 15.09 2 1 0.00 / 392.39 3 3
2 7 1895.48 29 14.36 2853 1188 1.19 / 393.57 3 3
3 13 1405.24 18 14.44 2317 602 1.79 / 394.18 3 3
4 13 900.68 18 14.61 1628 428 2.22 / 394.61 3 3
5 13 220.84 18 14.94 673 181 2.40 / 394.79 3 3
6 8 0.00 180 15.00 338 913 3.31 / 395.70 3 3
Average= 3.19
(KJ/cycle)

Cycle 122 GMT 26/ 9/2020 5: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 19 15.09 3 1 0.00 / 389.06 3 3
2 7 1896.36 30 14.36 2873 1238 1.24 / 390.30 3 3
3 13 1396.72 18 14.46 2262 589 1.83 / 390.89 3 3
4 13 883.20 18 14.62 1590 418 2.25 / 391.31 3 3
5 13 204.92 18 14.95 644 173 2.42 / 391.48 3 3
6 8 -0.12 180 15.01 335 905 3.32 / 392.39 3 3
Average= 3.19
(KJ/cycle)

Cycle 121 GMT 16/ 9/2020 4:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 19 15.09 3 1 0.00 / 385.78 3 3
2 7 1900.68 29 14.36 2876 1198 1.20 / 386.98 3 3
3 13 1406.88 18 14.45 2284 594 1.79 / 387.57 3 3
4 13 888.72 18 14.62 1588 418 2.21 / 387.99 3 3
5 13 211.92 18 14.95 655 176 2.39 / 388.16 3 3
6 8 0.12 180 15.01 332 897 3.28 / 389.06 3 3
Average= 3.19
(KJ/cycle)

Cycle 120 GMT 6/ 9/2020 4:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 19 15.09 4 1 0.00 / 382.47 3 3
2 7 1905.00 29 14.38 2871 1197 1.20 / 383.66 3 3
3 13 1412.76 18 14.45 2307 600 1.80 / 384.26 3 3
4 13 909.84 18 14.62 1612 424 2.22 / 384.69 3 3
5 13 225.96 18 14.94 681 183 2.41 / 384.87 3 3
6 8 0.16 180 15.01 336 908 3.31 / 385.78 3 3
Average= 3.19
(KJ/cycle)

Cycle 119 GMT 27/ 8/2020 3:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 20 15.09 2 1 0.00 / 379.16 3 3
2 7 1903.28 30 14.37 2850 1229 1.23 / 380.38 3 3
3 13 1416.60 18 14.46 2288 596 1.82 / 380.98 3 3
4 13 896.80 18 14.63 1590 419 2.24 / 381.40 3 3
5 13 210.20 18 14.95 648 174 2.42 / 381.57 3 3
6 8 0.00 180 15.01 330 892 3.31 / 382.46 3 3
Average= 3.19
(KJ/cycle)

Cycle 118 GMT 17/ 8/2020 3:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 20 15.09 3 1 0.00 / 375.87 3 3
2 7 1901.00 29 14.36 2847 1186 1.19 / 377.06 3 3
3 13 1407.24 18 14.46 2288 596 1.78 / 377.65 3 3
4 13 893.32 18 14.62 1603 422 2.20 / 378.07 3 3
5 13 214.32 18 14.95 653 176 2.38 / 378.25 3 3
6 8 0.12 180 15.01 335 905 3.28 / 379.16 3 3
Average= 3.19
(KJ/cycle)

Cycle 117 GMT 7/ 8/2020 2:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 20 15.09 3 1 0.00 / 372.58 3 3
2 7 1904.32 29 14.35 2873 1196 1.20 / 373.78 3 3
3 13 1396.84 18 14.46 2272 591 1.79 / 374.37 3 3
4 13 891.44 18 14.62 1606 423 2.21 / 374.79 3 3
5 13 204.40 18 14.95 652 175 2.39 / 374.97 3 3
6 8 0.24 180 15.01 334 902 3.29 / 375.87 3 3
Average= 3.19
(KJ/cycle)

Cycle 116 GMT 28/ 7/2020 2:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 19 15.09 3 1 0.00 / 369.28 3 3
2 3 1031.56 1 15.40 4 0 0.00 / 369.28 3 3
3 7 1898.28 29 14.35 2888 1202 1.20 / 370.49 3 3
4 13 1393.16 18 14.46 2280 593 1.80 / 371.08 3 3
5 13 883.68 18 14.63 1599 421 2.22 / 371.50 3 3
6 13 201.12 18 14.96 637 172 2.39 / 371.67 3 3
7 8 0.08 180 15.00 337 910 3.30 / 372.58 3 3
Average= 3.18
(KJ/cycle)

Cycle 115 GMT 18/ 7/2020 1:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 19 15.08 3 1 0.00 / 365.97 3 3
2 3 1023.16 1 15.40 4 0 0.00 / 365.97 3 3
3 7 1899.72 29 14.35 2895 1205 1.21 / 367.17 3 3
4 13 1405.24 18 14.45 2313 602 1.81 / 367.77 3 3
5 13 890.92 18 14.62 1622 427 2.23 / 368.20 3 3
6 13 198.52 18 14.95 647 174 2.41 / 368.37 3 3
7 8 0.24 180 15.00 337 910 3.32 / 369.28 3 3
Average= 3.18
(KJ/cycle)

Cycle 114 GMT 8/ 7/2020 1:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 19 15.09 3 1 0.00 / 362.62 3 3
2 7 1904.48 29 14.36 2874 1197 1.20 / 363.81 3 3
3 13 1394.28 18 14.47 2263 589 1.79 / 364.40 3 3
4 13 881.16 18 14.63 1578 416 2.20 / 364.82 3 3
5 13 336.00 18 14.87 840 225 2.43 / 365.04 3 3
6 8 0.24 180 14.99 342 923 3.35 / 365.97 3 3
Average= 3.18
(KJ/cycle)

Cycle 113 GMT 28/ 6/2020 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 18 15.10 3 1 0.00 / 359.35 3 3
2 10 1004.68 3 15.33 4 0 0.00 / 359.35 3 3
3 3 935.24 -1 15.40 0 0 0.00 / 359.35 3 3
4 3 971.52 -1 15.43 0 0 0.00 / 359.35 3 3
5 7 1899.60 29 14.37 2848 1187 1.19 / 360.54 3 3
6 13 1398.88 18 14.47 2258 588 1.78 / 361.12 3 3
7 13 889.24 18 14.63 1587 418 2.19 / 361.54 3 3
8 13 203.56 18 14.96 646 174 2.37 / 361.72 3 3
9 8 -0.08 180 15.01 333 900 3.27 / 362.61 3 3
Average= 3.18
(KJ/cycle)

Cycle 112 GMT 18/ 6/2020 0:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 19 15.08 4 1 0.00 / 356.06 3 3
2 3 970.44 -1 15.41 0 0 0.00 / 356.06 3 3
3 7 1900.88 29 14.36 2886 1202 1.20 / 357.26 3 3
4 13 1390.32 18 14.47 2277 593 1.80 / 357.86 3 3
5 13 873.56 18 14.64 1574 415 2.21 / 358.27 3 3
6 13 192.60 18 14.96 637 172 2.38 / 358.44 3 3
7 8 0.12 180 15.01 335 905 3.29 / 359.35 3 3
Average= 3.18
(KJ/cycle)

Cycle 111 GMT 8/ 6/2020 0:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 20 15.10 3 1 0.00 / 352.44 3 3
2 3 963.08 -1 15.41 0 0 0.00 / 352.44 3 3
3 7 1905.28 29 14.36 2883 1201 1.20 / 353.64 3 3
4 13 1415.88 18 14.46 2290 596 1.80 / 354.24 3 3
5 13 895.40 18 14.62 1615 425 2.22 / 354.66 3 3
6 13 209.60 18 14.95 663 178 2.40 / 354.84 3 3
7 8 0.28 180 15.01 339 916 3.32 / 355.76 3 3
8 14 0.28 60 14.97 335 301 3.62 / 356.06 3 3
Average= 3.18
(KJ/cycle)

Cycle 110 GMT 28/ 5/2020 23:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 20 15.10 3 1 0.00 / 349.16 3 3
2 3 1020.36 1 15.41 4 0 0.00 / 349.16 3 3
3 7 1898.32 29 14.37 2868 1195 1.20 / 350.36 3 3
4 13 1396.24 18 14.47 2261 589 1.79 / 350.94 3 3
5 13 883.04 18 14.63 1592 419 2.20 / 351.36 3 3
6 13 185.36 18 14.96 625 168 2.37 / 351.53 3 3
7 8 0.08 180 15.01 337 911 3.28 / 352.44 3 3
Average= 3.18
(KJ/cycle)

Cycle 109 GMT 18/ 5/2020 23:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 20 15.10 4 1 0.00 / 345.87 3 3
2 7 1895.92 29 14.36 2857 1190 1.19 / 347.06 3 3
3 13 1406.80 18 14.47 2288 596 1.79 / 347.65 3 3
4 13 902.68 18 14.61 1637 430 2.22 / 348.08 3 3
5 13 210.60 18 14.95 668 180 2.40 / 348.26 3 3
6 8 -0.20 180 15.01 332 897 3.29 / 349.16 3 3
Average= 3.17
(KJ/cycle)

Cycle 108 GMT 8/ 5/2020 22:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 20 15.10 3 1 0.00 / 342.59 3 3
2 7 1899.84 29 14.37 2848 1187 1.19 / 343.77 3 3
3 13 1400.08 18 14.47 2273 592 1.78 / 344.37 3 3
4 13 893.08 18 14.63 1612 425 2.20 / 344.79 3 3
5 13 209.76 18 14.96 658 177 2.38 / 344.97 3 3
6 8 0.04 180 15.02 332 898 3.28 / 345.86 3 3
Average= 3.17
(KJ/cycle)

Cycle 107 GMT 28/ 4/2020 22:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 20 15.10 3 1 0.00 / 339.32 3 3
2 7 1896.44 29 14.37 2854 1189 1.19 / 340.51 3 3
3 13 1388.08 18 14.47 2266 590 1.78 / 341.10 3 3
4 13 885.64 18 14.63 1603 422 2.20 / 341.52 3 3
5 13 195.60 18 14.96 637 172 2.37 / 341.70 3 3
6 8 -0.04 180 15.02 329 889 3.26 / 342.59 3 3
Average= 3.17
(KJ/cycle)

Cycle 106 GMT 18/ 4/2020 21:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 20 15.10 3 1 0.00 / 335.99 3 3
2 7 1903.32 30 14.37 2862 1234 1.23 / 337.23 3 3
3 13 1410.52 18 14.46 2294 597 1.83 / 337.82 3 3
4 13 899.28 18 14.62 1616 425 2.26 / 338.25 3 3
5 13 206.88 18 14.95 659 177 2.43 / 338.43 3 3
6 8 0.20 180 15.02 331 895 3.33 / 339.32 3 3
Average= 3.17
(KJ/cycle)

Cycle 105 GMT 8/ 4/2020 21:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 20 15.10 2 1 0.00 / 332.71 3 3
2 7 1898.68 29 14.38 2865 1195 1.20 / 333.90 3 3
3 13 1412.72 18 14.47 2287 596 1.79 / 334.50 3 3
4 13 891.80 18 14.64 1600 422 2.21 / 334.92 3 3
5 13 217.76 18 14.95 664 179 2.39 / 335.10 3 3
6 8 0.04 180 15.02 331 895 3.29 / 335.99 3 3
Average= 3.17
(KJ/cycle)

Cycle 104 GMT 29/ 3/2020 20:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 20 15.10 3 1 0.00 / 329.32 3 3
2 7 1893.36 29 14.38 2838 1184 1.18 / 330.50 3 3
3 13 1538.28 18 14.43 2473 642 1.83 / 331.14 3 3
4 13 996.48 18 14.58 1764 463 2.29 / 331.61 3 3
5 13 262.40 18 14.92 740 199 2.49 / 331.81 3 3
6 8 0.08 180 15.02 333 900 3.39 / 332.71 3 3
Average= 3.17
(KJ/cycle)

Cycle 103 GMT 19/ 3/2020 20:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 19 15.10 3 1 0.00 / 326.04 3 3
2 3 1024.96 1 15.41 4 0 0.00 / 326.04 3 3
3 7 1898.08 29 14.37 2852 1189 1.19 / 327.23 3 3
4 13 1397.92 18 14.47 2278 593 1.78 / 327.82 3 3
5 13 874.56 18 14.64 1578 416 2.20 / 328.24 3 3
6 13 206.92 18 14.96 656 177 2.38 / 328.41 3 3
7 8 0.08 180 15.02 334 903 3.28 / 329.32 3 3
Average= 3.17
(KJ/cycle)

Cycle 102 GMT 9/ 3/2020 19:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 19 15.09 3 1 0.00 / 322.74 3 3
2 7 1897.20 29 14.38 2847 1187 1.19 / 323.93 3 3
3 13 1403.44 18 14.47 2302 600 1.79 / 324.53 3 3
4 13 892.96 18 14.63 1619 426 2.21 / 324.96 3 3
5 13 209.16 18 14.95 664 179 2.39 / 325.14 3 3
6 8 0.04 180 15.02 334 903 3.30 / 326.04 3 3
Average= 3.17
(KJ/cycle)

Cycle 101 GMT 28/ 2/2020 19:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 19 15.10 2 1 0.00 / 319.36 3 3
2 7 1901.52 29 14.37 2859 1191 1.19 / 320.55 3 3
3 13 1396.00 18 14.49 2261 590 1.78 / 321.14 3 3
4 13 892.96 18 14.64 1592 420 2.20 / 321.56 3 3
5 13 210.36 18 14.96 653 176 2.38 / 321.74 3 3
6 13 19.72 18 15.05 367 99 2.48 / 321.84 3 3
7 8 0.20 180 15.01 335 905 3.38 / 322.74 3 3
Average= 3.16
(KJ/cycle)

Cycle 100 GMT 18/ 2/2020 19: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 19 15.10 3 1 0.00 / 316.00 3 3
2 7 1899.44 29 14.38 2870 1197 1.20 / 317.20 3 3
3 13 1396.64 18 14.47 2285 595 1.79 / 317.79 3 3
4 13 872.24 18 14.64 1572 414 2.21 / 318.21 3 3
5 13 187.60 18 14.98 617 166 2.37 / 318.37 3 3
6 13 17.52 18 15.06 359 97 2.47 / 318.47 3 3
7 8 0.08 180 15.01 330 892 3.36 / 319.36 3 3
Average= 3.16
(KJ/cycle)

Cycle 99 GMT 8/ 2/2020 18:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 19 15.11 2 1 0.00 / 312.61 3 3
2 7 1898.88 29 14.40 2861 1195 1.20 / 313.81 3 3
3 13 1408.04 18 14.48 2293 598 1.79 / 314.40 3 3
4 13 887.28 18 14.65 1594 420 2.21 / 314.82 3 3
5 13 211.16 18 14.97 653 176 2.39 / 315.00 3 3
6 13 18.16 18 15.06 368 100 2.49 / 315.10 3 3
7 8 0.08 180 15.01 333 900 3.39 / 316.00 3 3
Average= 3.16
(KJ/cycle)

Cycle 98 GMT 29/ 1/2020 18: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 19 15.11 4 1 0.00 / 309.34 3 3
2 7 1895.80 29 14.38 2864 1194 1.20 / 310.53 3 3
3 13 1396.24 18 14.48 2262 590 1.79 / 311.12 3 3
4 13 882.84 18 14.65 1586 418 2.20 / 311.54 3 3
5 13 201.12 18 14.97 638 172 2.38 / 311.71 3 3
6 8 0.20 180 15.02 332 898 3.27 / 312.61 3 3
Average= 3.16
(KJ/cycle)

Cycle 97 GMT 19/ 1/2020 17:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 19 15.11 3 1 0.00 / 306.09 3 3
2 7 1890.04 29 14.39 2829 1181 1.18 / 307.27 3 3
3 13 1385.96 18 14.50 2268 592 1.77 / 307.86 3 3
4 13 751.28 18 14.71 1418 375 2.15 / 308.24 3 3
5 13 227.00 18 14.95 691 186 2.33 / 308.42 3 3
6 8 0.08 180 15.02 339 917 3.25 / 309.34 3 3
Average= 3.16
(KJ/cycle)

Cycle 96 GMT 9/ 1/2020 17:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 19 15.11 2 1 0.00 / 302.79 3 3
2 7 1893.40 29 14.39 2850 1189 1.19 / 303.98 3 3
3 13 1403.04 18 14.48 2296 598 1.79 / 304.58 3 3
4 13 892.48 18 14.65 1613 425 2.21 / 305.00 3 3
5 13 205.12 18 14.97 653 176 2.39 / 305.18 3 3
6 8 0.20 180 15.03 336 909 3.30 / 306.09 3 3
Average= 3.16
(KJ/cycle)

Cycle 95 GMT 30/12/2019 16:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 20 15.12 3 1 0.00 / 299.52 3 3
2 3 972.84 -1 15.45 0 0 0.00 / 299.52 3 3
3 7 1891.12 29 14.39 2838 1184 1.19 / 300.70 3 3
4 13 1386.20 18 14.50 2252 588 1.77 / 301.29 3 3
5 13 884.52 18 14.66 1576 416 2.19 / 301.71 3 3
6 13 201.36 18 14.98 644 174 2.36 / 301.88 3 3
7 8 0.08 180 15.03 336 909 3.27 / 302.79 3 3
Average= 3.15
(KJ/cycle)

Cycle 94 GMT 20/12/2019 16:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 19 15.12 2 1 0.00 / 296.23 3 3
2 3 1033.88 1 15.42 4 0 0.00 / 296.23 3 3
3 7 1896.60 29 14.39 2875 1200 1.20 / 297.43 3 3
4 13 1392.48 18 14.50 2275 594 1.79 / 298.02 3 3
5 13 886.36 18 14.65 1599 422 2.22 / 298.44 3 3
6 13 186.84 18 14.99 626 169 2.38 / 298.61 3 3
7 8 0.08 180 15.03 335 906 3.29 / 299.52 3 3
Average= 3.15
(KJ/cycle)

Cycle 93 GMT 10/12/2019 15:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 19 15.12 3 1 0.00 / 292.89 3 3
2 7 1894.96 29 14.40 2860 1194 1.20 / 294.08 3 3
3 13 1390.28 18 14.50 2266 591 1.79 / 294.68 3 3
4 13 876.04 18 14.66 1579 417 2.20 / 295.09 3 3
5 13 340.88 18 14.90 847 227 2.43 / 295.32 3 3
6 8 0.16 180 15.03 335 906 3.34 / 296.23 3 3
Average= 3.15
(KJ/cycle)

Cycle 92 GMT 30/11/2019 15:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 19 15.13 2 1 0.00 / 289.59 3 3
2 7 1889.92 29 14.42 2831 1184 1.18 / 290.77 3 3
3 13 1398.92 18 14.50 2276 594 1.78 / 291.36 3 3
4 13 893.32 18 14.66 1600 422 2.20 / 291.79 3 3
5 13 217.88 18 14.98 676 182 2.38 / 291.97 3 3
6 8 0.04 180 15.04 340 920 3.30 / 292.89 3 3
Average= 3.15
(KJ/cycle)

Cycle 91 GMT 20/11/2019 15: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 19 15.12 4 1 0.00 / 286.32 3 3
2 7 1890.36 29 14.40 2839 1186 1.19 / 287.50 3 3
3 13 1382.04 18 14.51 2267 592 1.78 / 288.09 3 3
4 13 865.00 18 14.68 1561 412 2.19 / 288.51 3 3
5 13 185.12 18 15.00 624 168 2.36 / 288.68 3 3
6 8 0.08 180 15.05 336 910 3.27 / 289.59 3 3
Average= 3.15
(KJ/cycle)

Cycle 90 GMT 10/11/2019 14:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 19 15.13 3 1 0.00 / 282.82 3 3
2 7 1888.16 29 14.40 2870 1199 1.20 / 284.01 3 3
3 13 1531.76 18 14.47 2446 637 1.84 / 284.65 3 3
4 13 841.48 18 14.69 1535 406 2.24 / 285.06 3 3
5 13 311.32 18 14.93 820 220 2.46 / 285.28 3 3
6 13 23.96 18 15.07 386 105 2.57 / 285.38 3 3
7 8 -0.12 180 15.03 345 933 3.50 / 286.32 3 3
Average= 3.15
(KJ/cycle)

Cycle 89 GMT 31/10/2019 14:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 19 15.14 2 1 0.00 / 279.55 3 3
2 7 1886.92 29 14.41 2816 1177 1.18 / 280.72 3 3
3 13 1390.16 18 14.52 2260 591 1.77 / 281.31 3 3
4 13 875.96 18 14.68 1581 418 2.19 / 281.73 3 3
5 13 187.92 18 15.00 635 171 2.36 / 281.90 3 3
6 8 0.00 180 15.05 337 913 3.27 / 282.81 3 3
Average= 3.14
(KJ/cycle)

Cycle 88 GMT 21/10/2019 13:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 20 15.14 3 1 0.00 / 276.27 3 3
2 3 972.76 -1 15.46 0 0 0.00 / 276.27 3 3
3 7 1889.40 29 14.39 2857 1192 1.19 / 277.46 3 3
4 13 1385.00 18 14.52 2245 587 1.78 / 278.05 3 3
5 13 880.20 18 14.69 1578 417 2.20 / 278.47 3 3
6 13 196.44 18 15.01 629 170 2.37 / 278.64 3 3
7 8 0.24 180 15.06 335 908 3.28 / 279.54 3 3
Average= 3.14
(KJ/cycle)

Cycle 87 GMT 11/10/2019 13:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 20 15.15 3 1 0.00 / 272.91 3 3
2 7 1887.24 29 14.41 2854 1193 1.19 / 274.10 3 3
3 13 1392.04 18 14.51 2272 593 1.79 / 274.70 3 3
4 13 873.32 18 14.68 1582 418 2.20 / 275.11 3 3
5 13 330.88 18 14.92 846 227 2.43 / 275.34 3 3
6 8 0.04 180 15.05 343 929 3.36 / 276.27 3 3
Average= 3.14
(KJ/cycle)

Cycle 86 GMT 1/10/2019 13: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 19 15.15 2 1 0.00 / 269.56 3 3
2 3 1029.76 1 15.44 4 0 0.00 / 269.56 3 3
3 7 1894.80 30 14.40 2873 1241 1.24 / 270.80 3 3
4 13 1388.28 18 14.52 2266 592 1.83 / 271.39 3 3
5 13 874.92 18 14.69 1580 418 2.25 / 271.81 3 3
6 13 190.64 18 15.02 638 172 2.42 / 271.98 3 3
7 8 0.12 180 15.06 341 924 3.35 / 272.91 3 3
Average= 3.14
(KJ/cycle)

Cycle 85 GMT 21/ 9/2019 12:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 20 15.15 3 1 0.00 / 266.24 3 3
2 3 970.44 -1 15.44 0 0 0.00 / 266.24 3 3
3 7 1890.64 29 14.40 2866 1197 1.20 / 267.44 3 3
4 13 1389.28 18 14.53 2266 593 1.79 / 268.03 3 3
5 13 886.84 18 14.69 1594 421 2.21 / 268.45 3 3
6 13 193.96 18 15.01 647 175 2.39 / 268.62 3 3
7 8 -0.04 180 15.06 345 935 3.32 / 269.56 3 3
Average= 3.13
(KJ/cycle)

Cycle 84 GMT 11/ 9/2019 12:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 19 15.16 3 1 0.00 / 262.96 3 3
2 3 1035.96 1 15.44 4 0 0.00 / 262.96 3 3
3 7 1888.96 29 14.41 2875 1201 1.20 / 264.16 3 3
4 13 1366.76 18 14.54 2222 582 1.78 / 264.74 3 3
5 13 859.84 18 14.71 1545 409 2.19 / 265.15 3 3
6 13 171.56 18 15.03 610 165 2.36 / 265.32 3 3
7 8 0.20 180 15.07 339 920 3.28 / 266.24 3 3
Average= 3.13
(KJ/cycle)

Cycle 83 GMT 1/ 9/2019 11:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 18 15.15 4 1 0.00 / 259.66 3 3
2 3 1028.28 1 15.45 4 0 0.00 / 259.66 3 3
3 7 1887.80 29 14.41 2866 1198 1.20 / 260.86 3 3
4 13 1380.80 18 14.54 2247 588 1.79 / 261.44 3 3
5 13 862.92 18 14.71 1568 415 2.20 / 261.86 3 3
6 13 184.40 18 15.02 632 171 2.37 / 262.03 3 3
7 8 0.20 180 15.07 343 930 3.30 / 262.96 3 3
Average= 3.13
(KJ/cycle)

Cycle 82 GMT 22/ 8/2019 11:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 19 15.14 3 1 0.00 / 256.01 3 3
2 3 961.40 -1 15.45 0 0 0.00 / 256.01 3 3
3 7 1885.04 29 14.41 2848 1190 1.19 / 257.20 3 3
4 13 1391.32 18 14.54 2272 595 1.79 / 257.79 3 3
5 13 885.64 18 14.69 1603 424 2.21 / 258.22 3 3
6 13 188.16 18 15.03 645 174 2.38 / 258.39 3 3
7 8 -0.16 180 15.07 351 952 3.34 / 259.34 3 3
8 14 -0.16 60 15.03 347 313 3.65 / 259.66 3 3
Average= 3.13
(KJ/cycle)

Cycle 81 GMT 12/ 8/2019 10:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 19 15.16 3 1 0.00 / 252.38 3 3
2 7 1885.64 29 14.42 2849 1191 1.19 / 253.58 3 3
3 13 1390.16 18 14.54 2247 588 1.78 / 254.16 3 3
4 13 878.16 18 14.71 1565 414 2.19 / 254.58 3 3
5 13 188.84 18 15.03 643 174 2.37 / 254.75 3 3
6 8 0.16 180 15.07 348 944 3.31 / 255.70 3 3
7 14 0.16 60 15.03 345 311 3.62 / 256.01 3 3
Average= 3.12
(KJ/cycle)

Cycle 80 GMT 2/ 8/2019 10:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 20 15.16 4 1 0.00 / 249.03 3 3
2 7 1880.36 29 14.42 2847 1191 1.19 / 250.22 3 3
3 13 1536.16 18 14.50 2454 640 1.83 / 250.86 3 3
4 13 846.60 18 14.72 1555 412 2.24 / 251.27 3 3
5 13 171.20 18 15.04 617 167 2.41 / 251.44 3 3
6 8 0.16 180 15.08 349 947 3.36 / 252.38 3 3
Average= 3.12
(KJ/cycle)

Cycle 79 GMT 23/ 7/2019 10: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.92 19 15.19 3 1 0.00 / 245.65 3 3
2 7 1896.92 29 14.43 2863 1198 1.20 / 246.85 3 3
3 13 1414.16 18 14.54 2301 602 1.80 / 247.45 3 3
4 13 906.00 18 14.69 1631 431 2.23 / 247.88 3 3
5 13 224.68 18 15.01 698 189 2.42 / 248.07 3 3
6 8 0.28 180 15.07 351 952 3.37 / 249.03 3 3
Average= 3.11
(KJ/cycle)

Cycle 78 GMT 13/ 7/2019 9:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 19 15.18 3 1 0.00 / 242.55 3 3
2 3 1024.96 1 15.46 4 0 0.00 / 242.55 3 3
3 7 1602.04 29 14.55 2505 1057 1.06 / 243.61 3 3
4 13 1304.76 18 14.62 2139 563 1.62 / 244.17 3 3
5 13 818.60 18 14.77 1490 396 2.02 / 244.57 3 3
6 13 145.36 18 15.08 567 154 2.17 / 244.72 3 3
7 8 0.08 180 15.10 343 932 3.10 / 245.65 3 3
Average= 3.11
(KJ/cycle)

Cycle 77 GMT 3/ 7/2019 9:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 19 15.19 3 1 0.00 / 239.27 3 3
2 7 1885.84 29 14.42 2845 1190 1.19 / 240.46 3 3
3 13 1385.44 18 14.56 2258 592 1.78 / 241.05 3 3
4 13 857.64 18 14.73 1554 412 2.19 / 241.46 3 3
5 13 173.08 18 15.06 605 164 2.36 / 241.63 3 3
6 8 0.20 180 15.10 339 921 3.28 / 242.55 3 3
Average= 3.11
(KJ/cycle)

Cycle 76 GMT 23/ 6/2019 9:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 19 15.18 3 1 0.00 / 235.99 3 3
2 7 1889.36 29 14.43 2859 1196 1.20 / 237.18 3 3
3 13 1392.36 18 14.55 2248 589 1.79 / 237.77 3 3
4 13 882.48 18 14.72 1579 418 2.20 / 238.19 3 3
5 13 187.80 18 15.06 627 170 2.37 / 238.36 3 3
6 8 0.04 180 15.10 335 911 3.28 / 239.27 3 3
Average= 3.11
(KJ/cycle)

Cycle 75 GMT 13/ 6/2019 8:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 19 15.19 3 1 0.00 / 232.61 3 3
2 7 1888.04 29 14.43 2854 1194 1.20 / 233.81 3 3
3 13 1380.92 18 14.56 2247 589 1.78 / 234.39 3 3
4 13 869.36 18 14.73 1561 414 2.20 / 234.81 3 3
5 13 188.12 18 15.06 627 170 2.37 / 234.98 3 3
6 13 44.80 18 15.13 401 109 2.48 / 235.09 3 3
7 8 0.00 180 15.10 330 897 3.37 / 235.98 3 3
Average= 3.11
(KJ/cycle)

Cycle 74 GMT 3/ 6/2019 8:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 19 15.20 2 1 0.00 / 229.35 3 3
2 7 1888.28 29 14.44 2846 1192 1.19 / 230.55 3 3
3 13 1381.44 18 14.57 2230 585 1.78 / 231.13 3 3
4 13 871.40 18 14.74 1558 413 2.19 / 231.54 3 3
5 13 177.80 18 15.07 608 165 2.36 / 231.71 3 3
6 8 0.16 180 15.11 331 900 3.26 / 232.61 3 3
Average= 3.10
(KJ/cycle)

Cycle 73 GMT 24/ 5/2019 7:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 19 15.20 3 1 0.00 / 226.06 3 3
2 7 1889.32 29 14.43 2864 1198 1.20 / 227.26 3 3
3 13 1385.16 18 14.57 2251 590 1.79 / 227.85 3 3
4 13 887.04 18 14.73 1590 422 2.21 / 228.27 3 3
5 13 180.80 18 15.07 621 168 2.38 / 228.44 3 3
6 8 0.08 180 15.11 336 914 3.29 / 229.35 3 3
Average= 3.10
(KJ/cycle)

Cycle 72 GMT 14/ 5/2019 7:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 19 15.20 3 1 0.00 / 222.70 3 3
2 7 1884.64 29 14.45 2862 1199 1.20 / 223.90 3 3
3 13 1405.84 18 14.56 2286 599 1.80 / 224.50 3 3
4 13 894.04 18 14.73 1619 429 2.23 / 224.93 3 3
5 13 212.56 18 15.05 677 183 2.41 / 225.11 3 3
6 8 0.16 180 15.11 349 949 3.36 / 226.06 3 3
Average= 3.10
(KJ/cycle)

Cycle 71 GMT 4/ 5/2019 6:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 18 15.20 2 1 0.00 / 219.42 3 3
2 7 1882.36 30 14.42 2855 1235 1.24 / 220.65 3 3
3 13 1364.72 17 14.57 2257 559 1.79 / 221.21 3 3
4 13 861.28 17 14.75 1562 392 2.19 / 221.60 3 3
5 13 198.96 17 15.05 657 168 2.35 / 221.77 3 3
6 8 0.20 180 15.11 342 930 3.28 / 222.70 3 3
Average= 3.09
(KJ/cycle)

Cycle 70 GMT 24/ 4/2019 6:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 18 15.20 3 1 0.00 / 216.15 3 3
2 7 1883.20 30 14.44 2826 1224 1.23 / 217.38 3 3
3 13 1370.96 17 14.57 2232 553 1.78 / 217.93 3 3
4 13 878.20 17 14.75 1577 395 2.17 / 218.33 3 3
5 13 201.76 17 15.06 652 167 2.34 / 218.49 3 3
6 8 0.04 180 15.12 339 923 3.26 / 219.41 3 3
Average= 3.09
(KJ/cycle)

Cycle 69 GMT 14/ 4/2019 5:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 18 15.20 2 1 0.00 / 212.77 3 3
2 7 1883.24 30 14.43 2859 1238 1.24 / 214.00 3 3
3 13 1363.80 17 14.58 2232 553 1.79 / 214.56 3 3
4 13 842.52 17 14.76 1532 384 2.18 / 214.94 3 3
5 13 177.88 17 15.07 630 161 2.34 / 215.10 3 3
6 13 36.52 17 15.14 419 108 2.45 / 215.21 3 3
7 8 0.04 180 15.11 346 941 3.39 / 216.15 3 3
Average= 3.09
(KJ/cycle)

Cycle 68 GMT 4/ 4/2019 5:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 18 15.20 3 1 0.00 / 209.44 3 3
2 7 1886.04 30 14.44 2836 1229 1.23 / 210.67 3 3
3 13 1362.92 16 14.60 2229 521 1.75 / 211.19 3 3
4 13 881.08 16 14.76 1593 376 2.13 / 211.57 3 3
5 13 209.72 16 15.06 673 162 2.29 / 211.73 3 3
6 13 47.76 16 15.14 430 104 2.39 / 211.83 3 3
7 8 0.04 180 15.11 343 933 3.33 / 212.77 3 3
Average= 3.08
(KJ/cycle)

Cycle 67 GMT 25/ 3/2019 4:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 18 15.21 3 1 0.00 / 206.02 3 3
2 7 1880.68 30 14.46 2835 1230 1.23 / 207.25 3 3
3 13 1375.04 16 14.61 2218 518 1.75 / 207.77 3 3
4 13 1030.04 16 14.70 1781 419 2.17 / 208.19 3 3
5 13 325.92 16 15.00 844 203 2.37 / 208.39 3 3
6 13 66.08 16 15.12 472 114 2.48 / 208.50 3 3
7 8 0.04 180 15.12 344 936 3.42 / 209.44 3 3
Average= 3.08
(KJ/cycle)

Cycle 66 GMT 15/ 3/2019 4:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 19 15.21 4 1 0.00 / 202.70 3 3
2 7 1881.04 30 14.45 2811 1219 1.22 / 203.92 3 3
3 13 1371.20 16 14.60 2237 523 1.74 / 204.44 3 3
4 13 865.84 16 14.78 1550 367 2.11 / 204.81 3 3
5 13 351.52 16 15.00 853 205 2.31 / 205.01 3 3
6 13 43.92 16 15.15 414 100 2.41 / 205.11 3 3
7 8 -0.04 180 15.12 333 906 3.32 / 206.02 3 3
Average= 3.07
(KJ/cycle)

Cycle 65 GMT 5/ 3/2019 4: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 19 15.21 3 1 0.00 / 199.39 3 3
2 7 1878.76 30 14.44 2836 1229 1.23 / 200.62 3 3
3 13 1368.96 16 14.61 2225 520 1.75 / 201.14 3 3
4 13 877.96 16 14.77 1582 374 2.12 / 201.51 3 3
5 13 224.92 16 15.07 689 166 2.29 / 201.68 3 3
6 13 45.80 16 15.15 424 103 2.39 / 201.78 3 3
7 8 0.24 180 15.12 337 917 3.31 / 202.70 3 3
Average= 3.07
(KJ/cycle)

Cycle 64 GMT 23/ 2/2019 3:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 19 15.21 2 1 0.00 / 196.00 3 3
2 7 1879.84 30 14.45 2858 1239 1.24 / 197.24 3 3
3 13 1371.60 16 14.61 2233 522 1.76 / 197.76 3 3
4 13 862.72 16 14.79 1560 369 2.13 / 198.13 3 3
5 13 352.96 16 15.00 885 212 2.34 / 198.35 3 3
6 13 39.40 16 15.15 420 102 2.44 / 198.45 3 3
7 8 0.04 180 15.12 346 942 3.39 / 199.39 3 3
Average= 3.07
(KJ/cycle)

Cycle 63 GMT 13/ 2/2019 3:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 19 15.22 3 1 0.00 / 192.59 3 3
2 7 1881.92 31 14.44 2859 1280 1.28 / 193.87 3 3
3 13 1363.36 16 14.61 2212 517 1.80 / 194.38 3 3
4 13 877.96 16 14.78 1584 375 2.17 / 194.76 3 3
5 13 374.40 16 14.99 899 216 2.39 / 194.97 3 3
6 13 43.80 16 15.15 424 103 2.49 / 195.08 3 3
7 8 0.16 180 15.12 341 928 3.42 / 196.00 3 3
Average= 3.06
(KJ/cycle)

Cycle 62 GMT 3/ 2/2019 2:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 19 15.23 3 1 0.00 / 189.26 3 3
2 7 1882.80 30 14.45 2843 1232 1.23 / 190.49 3 3
3 13 1371.68 16 14.61 2253 527 1.76 / 191.02 3 3
4 13 879.72 16 14.78 1578 373 2.13 / 191.39 3 3
5 13 342.04 16 15.02 845 203 2.34 / 191.60 3 3
6 13 35.08 16 15.17 393 95 2.43 / 191.69 3 3
7 8 0.20 180 15.14 328 894 3.33 / 192.58 3 3
Average= 3.06
(KJ/cycle)

Cycle 61 GMT 24/ 1/2019 2:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 19 15.21 2 1 0.00 / 185.95 3 3
2 7 1879.24 30 14.45 2824 1224 1.22 / 187.18 3 3
3 13 1352.32 16 14.63 2206 516 1.74 / 187.70 3 3
4 13 857.20 16 14.80 1568 371 2.11 / 188.07 3 3
5 13 324.56 16 15.02 835 201 2.31 / 188.27 3 3
6 13 32.28 16 15.18 391 95 2.41 / 188.36 3 3
7 8 0.08 180 15.14 329 897 3.30 / 189.26 3 3
Average= 3.05
(KJ/cycle)

Cycle 60 GMT 14/ 1/2019 2: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 19 15.22 3 1 0.00 / 182.29 3 3
2 7 1879.12 30 14.44 2862 1240 1.24 / 183.53 3 3
3 13 1361.52 16 14.62 2244 525 1.77 / 184.06 3 3
4 13 874.32 16 14.79 1584 375 2.14 / 184.43 3 3
5 13 339.04 16 15.03 852 205 2.35 / 184.64 3 3
6 13 29.16 16 15.17 395 96 2.44 / 184.73 3 3
7 8 0.04 180 15.14 336 916 3.36 / 185.65 3 3
8 14 0.04 60 15.11 335 304 3.66 / 185.95 3 4
Average= 3.05
(KJ/cycle)

Cycle 59 GMT 4/ 1/2019 1:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 19 15.23 3 1 0.00 / 178.94 3 3
2 7 1880.92 30 14.46 2842 1233 1.23 / 180.17 3 3
3 13 1376.16 16 14.62 2230 522 1.76 / 180.69 3 3
4 13 875.28 16 14.80 1568 371 2.13 / 181.06 3 3
5 13 357.16 16 15.02 862 207 2.33 / 181.27 3 3
6 13 35.12 16 15.17 404 98 2.43 / 181.37 3 3
7 8 0.00 180 15.14 340 927 3.36 / 182.29 3 3
Average= 3.04
(KJ/cycle)

Cycle 58 GMT 25/12/2018 1:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 18 15.23 2 1 0.00 / 175.60 3 3
2 3 1029.04 1 15.49 3 0 0.00 / 175.60 3 3
3 7 1881.36 30 14.47 2864 1243 1.24 / 176.84 3 3
4 13 1384.68 16 14.62 2258 528 1.77 / 177.37 3 3
5 13 891.80 16 14.78 1606 380 2.15 / 177.75 3 3
6 13 232.28 16 15.08 697 168 2.32 / 177.92 3 3
7 13 25.64 16 15.18 391 95 2.41 / 178.01 3 3
8 8 0.16 180 15.14 338 921 3.34 / 178.94 3 3
Average= 3.03
(KJ/cycle)

Cycle 57 GMT 15/12/2018 0:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 19 15.21 3 1 0.00 / 172.34 3 3
2 3 966.92 -1 15.49 0 0 0.00 / 172.34 3 3
3 7 1879.96 30 14.46 2832 1229 1.23 / 173.57 3 3
4 13 1246.36 16 14.68 2062 484 1.71 / 174.05 3 3
5 13 776.64 16 14.84 1455 345 2.06 / 174.40 3 3
6 13 272.60 16 15.06 755 182 2.24 / 174.58 3 3
7 13 25.88 16 15.18 388 94 2.34 / 174.68 3 3
8 8 0.00 180 15.14 339 924 3.26 / 175.60 3 3
Average= 3.03
(KJ/cycle)

Cycle 56 GMT 5/12/2018 0: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 19 15.27 3 1 0.00 / 168.70 3 3
2 7 1881.88 30 14.47 2812 1221 1.22 / 169.92 3 3
3 13 1374.28 16 14.63 2217 519 1.74 / 170.44 3 3
4 13 878.12 16 14.79 1583 375 2.12 / 170.81 3 3
5 13 222.04 16 15.09 693 167 2.28 / 170.98 3 3
6 13 23.80 16 15.18 392 95 2.38 / 171.08 3 3
7 8 0.00 180 15.14 350 954 3.33 / 172.03 3 3
8 14 0.00 60 15.10 343 311 3.64 / 172.34 3 3
Average= 3.02
(KJ/cycle)

Cycle 55 GMT 24/11/2018 23:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 19 15.25 3 1 0.00 / 165.85 3 3
2 7 1333.60 30 14.71 2165 955 0.96 / 166.80 3 3
3 13 1200.68 16 14.76 2003 473 1.43 / 167.27 3 3
4 13 707.68 16 14.92 1376 328 1.76 / 167.60 3 3
5 13 183.56 16 15.14 639 155 1.91 / 167.76 3 3
6 8 -0.04 180 15.18 344 940 2.85 / 168.70 3 3
Average= 3.01
(KJ/cycle)

Cycle 54 GMT 15/11/2018 0: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 19 15.25 3 1 0.00 / 162.63 3 3
2 7 1883.04 30 14.48 2819 1225 1.23 / 163.85 3 3
3 13 1371.88 16 14.64 2236 524 1.75 / 164.38 3 3
4 13 873.44 16 14.81 1572 373 2.12 / 164.75 3 3
5 13 222.40 16 15.10 688 166 2.29 / 164.92 3 3
6 8 0.04 180 15.16 340 928 3.22 / 165.85 3 3
Average= 3.02
(KJ/cycle)

Cycle 53 GMT 4/11/2018 23:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 19 15.25 3 1 0.00 / 159.43 3 3
2 7 1878.60 30 14.48 2820 1225 1.23 / 160.65 3 3
3 13 1386.32 16 14.63 2262 529 1.76 / 161.18 3 3
4 13 879.04 16 14.81 1573 373 2.13 / 161.56 3 3
5 13 218.92 16 15.10 668 161 2.29 / 161.72 3 3
6 8 0.08 180 15.17 334 912 3.20 / 162.63 3 3
Average= 3.01
(KJ/cycle)

Cycle 52 GMT 25/10/2018 23: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 19 15.25 3 1 0.00 / 156.16 3 3
2 7 1878.64 30 14.47 2820 1224 1.23 / 157.39 3 3
3 13 1367.24 16 14.65 2214 519 1.74 / 157.91 3 3
4 13 874.88 16 14.81 1578 374 2.12 / 158.28 3 3
5 13 361.08 16 15.03 875 210 2.33 / 158.49 3 3
6 8 0.04 180 15.16 343 936 3.26 / 159.43 3 3
Average= 3.01
(KJ/cycle)

Cycle 51 GMT 15/10/2018 22:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 19 15.25 3 1 0.00 / 152.95 3 3
2 7 1882.08 30 14.48 2834 1231 1.23 / 154.18 3 3
3 13 1361.64 16 14.64 2225 521 1.75 / 154.70 3 3
4 13 863.72 16 14.82 1574 373 2.13 / 155.08 3 3
5 13 194.40 16 15.12 639 155 2.28 / 155.23 3 3
6 8 0.12 180 15.17 342 934 3.21 / 156.16 3 3
Average= 3.00
(KJ/cycle)

Cycle 50 GMT 5/10/2018 22:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 19 15.25 3 1 0.00 / 149.65 3 3
2 7 1877.84 30 14.49 2825 1228 1.23 / 150.87 3 3
3 13 1392.76 16 14.64 2261 530 1.76 / 151.40 3 3
4 13 898.24 16 14.81 1602 380 2.14 / 151.78 3 3
5 13 382.60 16 15.03 908 218 2.36 / 152.00 3 3
6 8 0.16 180 15.16 347 947 3.30 / 152.95 3 3
Average= 3.00
(KJ/cycle)

Cycle 49 GMT 25/ 9/2018 21:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 19 15.26 4 1 0.00 / 146.37 3 3
2 7 1874.88 30 14.47 2854 1239 1.24 / 147.61 3 3
3 13 1346.04 16 14.65 2222 521 1.76 / 148.13 3 3
4 13 840.04 16 14.83 1558 370 2.13 / 148.50 3 3
5 13 314.68 16 15.06 824 199 2.33 / 148.70 3 3
6 8 0.08 180 15.17 347 948 3.28 / 149.65 3 3
Average= 2.99
(KJ/cycle)

Cycle 48 GMT 15/ 9/2018 21:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 19 15.26 2 1 0.00 / 143.09 3 3
2 7 1875.00 30 14.48 2839 1233 1.23 / 144.32 3 3
3 13 1353.96 16 14.65 2217 520 1.75 / 144.84 3 3
4 13 858.76 16 14.83 1550 368 2.12 / 145.21 3 3
5 13 319.32 16 15.06 837 202 2.32 / 145.41 3 3
6 8 0.12 180 15.17 350 956 3.28 / 146.37 3 3
Average= 2.99
(KJ/cycle)

Cycle 47 GMT 5/ 9/2018 21: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.52 19 15.26 3 1 0.00 / 139.80 3 3
2 3 1030.48 1 15.51 3 0 0.00 / 139.80 3 3
3 7 1875.64 30 14.49 2839 1234 1.24 / 141.03 3 3
4 13 1368.68 16 14.65 2244 526 1.76 / 141.56 3 3
5 13 877.48 16 14.82 1592 377 2.14 / 141.94 3 3
6 13 365.48 16 15.04 895 215 2.35 / 142.15 3 3
7 8 0.28 180 15.17 344 939 3.29 / 143.09 3 3
Average= 2.98
(KJ/cycle)

Cycle 46 GMT 26/ 8/2018 20:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 19 15.26 2 1 0.00 / 136.54 3 3
2 7 1874.64 30 14.49 2829 1230 1.23 / 137.77 3 3
3 13 1233.20 16 14.69 2098 493 1.72 / 138.26 3 3
4 13 917.40 16 14.79 1652 391 2.11 / 138.65 3 3
5 13 237.84 16 15.10 735 178 2.29 / 138.83 3 3
6 8 0.28 180 15.17 354 967 3.26 / 139.80 3 3
Average= 2.97
(KJ/cycle)

Cycle 45 GMT 16/ 8/2018 20: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 18 15.27 3 1 0.00 / 133.29 3 3
2 3 1023.80 1 15.52 4 0 0.00 / 133.29 3 3
3 7 1872.08 30 14.50 2821 1227 1.23 / 134.51 3 3
4 13 1341.32 16 14.66 2213 519 1.75 / 135.03 3 3
5 13 835.56 16 14.84 1520 361 2.11 / 135.39 3 3
6 13 322.28 16 15.07 826 199 2.31 / 135.59 3 3
7 8 -0.04 180 15.18 346 945 3.25 / 136.54 3 3
Average= 2.97
(KJ/cycle)

Cycle 44 GMT 6/ 8/2018 19:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 17 15.27 3 1 0.00 / 129.91 3 3
2 3 1031.44 1 15.52 4 0 0.00 / 129.91 3 3
3 7 1870.40 31 14.49 2837 1274 1.28 / 131.18 3 3
4 13 1359.68 16 14.65 2263 530 1.81 / 131.72 3 3
5 13 1019.24 16 14.76 1792 423 2.23 / 132.14 3 3
6 13 306.96 16 15.07 815 197 2.43 / 132.33 3 3
7 8 0.12 180 15.18 348 951 3.38 / 133.29 3 3
Average= 2.96
(KJ/cycle)

Cycle 43 GMT 27/ 7/2018 19:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 19 15.26 2 1 0.00 / 126.67 3 3
2 3 948.44 -1 15.52 0 0 0.00 / 126.67 3 3
3 7 1871.56 30 14.50 2822 1228 1.23 / 127.90 3 3
4 13 1362.64 16 14.66 2250 528 1.76 / 128.43 3 3
5 13 857.52 16 14.83 1558 370 2.13 / 128.80 3 3
6 13 359.04 16 15.05 875 211 2.34 / 129.01 3 3
7 8 -0.08 180 15.19 330 902 3.24 / 129.91 3 3
Average= 2.95
(KJ/cycle)

Cycle 42 GMT 17/ 7/2018 19: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 19 15.27 2 1 0.00 / 123.20 3 3
2 7 1872.92 30 14.50 2811 1223 1.22 / 124.42 3 3
3 13 1361.32 16 14.67 2195 515 1.74 / 124.94 3 3
4 13 854.40 16 14.85 1528 363 2.10 / 125.30 3 3
5 13 333.32 16 15.07 832 201 2.30 / 125.50 3 3
6 8 0.16 180 15.19 323 883 3.19 / 126.38 3 3
7 14 0.16 60 15.16 317 288 3.47 / 126.67 3 3
Average= 2.95
(KJ/cycle)

Cycle 41 GMT 7/ 7/2018 18:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 19 15.28 3 1 0.00 / 120.04 3 3
2 7 1872.88 30 14.52 2785 1213 1.21 / 121.26 3 3
3 13 1357.68 16 14.68 2179 512 1.73 / 121.77 3 3
4 13 861.12 16 14.86 1511 359 2.09 / 122.13 3 3
5 13 330.52 16 15.08 800 193 2.28 / 122.32 3 3
6 8 0.12 180 15.20 320 876 3.15 / 123.20 3 3
Average= 2.93
(KJ/cycle)

Cycle 40 GMT 27/ 6/2018 18:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 19 15.29 3 1 0.00 / 116.95 3 3
2 7 1875.12 31 14.52 2781 1252 1.25 / 118.20 3 3
3 13 1359.76 16 14.69 2182 513 1.77 / 118.72 3 3
4 13 853.36 16 14.87 1500 357 2.12 / 119.07 3 3
5 13 204.40 16 15.16 619 150 2.27 / 119.22 3 3
6 8 -0.16 180 15.21 300 821 3.09 / 120.04 3 3
Average= 2.93
(KJ/cycle)

Cycle 39 GMT 17/ 6/2018 17:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 19 15.28 3 1 0.00 / 113.85 3 3
2 7 1873.84 30 14.53 2788 1215 1.22 / 115.07 3 3
3 13 1385.20 16 14.69 2219 522 1.74 / 115.59 3 3
4 13 879.60 16 14.86 1555 370 2.11 / 115.96 3 3
5 13 237.28 16 15.14 672 163 2.27 / 116.12 3 3
6 8 0.20 180 15.22 303 830 3.10 / 116.95 3 3
Average= 2.92
(KJ/cycle)

Cycle 38 GMT 7/ 6/2018 17:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 19 15.30 3 1 0.00 / 110.61 3 3
2 7 1875.80 30 14.53 2808 1224 1.22 / 111.83 3 3
3 13 1383.68 16 14.69 2215 521 1.75 / 112.35 3 3
4 13 888.60 16 14.86 1552 369 2.11 / 112.72 3 3
5 13 369.80 16 15.08 855 206 2.32 / 112.93 3 3
6 13 19.76 16 15.24 337 82 2.40 / 113.01 3 3
7 8 0.36 180 15.21 307 841 3.24 / 113.85 3 3
Average= 2.92
(KJ/cycle)

Cycle 37 GMT 28/ 5/2018 16:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 19 15.29 3 1 0.00 / 107.55 3 3
2 7 1879.52 30 14.52 2812 1225 1.23 / 108.78 3 3
3 13 1368.48 16 14.70 2192 516 1.74 / 109.29 3 3
4 13 859.48 16 14.87 1505 358 2.10 / 109.65 3 3
5 13 205.76 16 15.17 608 148 2.25 / 109.80 3 3
6 8 -0.08 180 15.23 294 806 3.05 / 110.61 3 3
Average= 2.91
(KJ/cycle)

Cycle 36 GMT 18/ 5/2018 16:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 18 15.30 3 1 0.00 / 104.46 3 3
2 3 1021.88 1 15.54 4 0 0.00 / 104.46 3 3
3 7 1872.76 30 14.53 2794 1218 1.22 / 105.67 3 3
4 13 1353.68 16 14.70 2173 511 1.73 / 106.19 3 3
5 13 857.92 16 14.88 1525 363 2.09 / 106.55 3 3
6 13 323.36 16 15.10 790 191 2.28 / 106.74 3 3
7 8 -0.04 180 15.22 297 814 3.10 / 107.55 3 3
Average= 2.91
(KJ/cycle)

Cycle 35 GMT 8/ 5/2018 15:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 18 15.30 3 1 0.00 / 101.28 3 3
2 7 1874.04 30 14.53 2803 1222 1.22 / 102.50 3 3
3 13 1356.60 16 14.72 2178 513 1.74 / 103.01 3 3
4 13 850.48 16 14.89 1498 357 2.09 / 103.37 3 3
5 13 325.64 16 15.11 791 191 2.28 / 103.56 3 3
6 13 33.88 16 15.25 347 85 2.37 / 103.65 3 3
7 8 0.24 180 15.22 295 808 3.18 / 104.46 3 3
Average= 2.90
(KJ/cycle)

Cycle 34 GMT 28/ 4/2018 15:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 19 15.30 2 1 0.00 / 98.05 3 3
2 7 1869.96 30 14.55 2798 1221 1.22 / 99.27 3 3
3 13 1380.32 16 14.71 2207 519 1.74 / 99.79 3 3
4 13 881.76 16 14.87 1542 367 2.11 / 100.16 3 3
5 13 361.76 16 15.09 844 204 2.31 / 100.36 3 3
6 13 42.40 16 15.25 368 90 2.40 / 100.45 3 3
7 8 0.00 180 15.22 301 825 3.23 / 101.28 3 3
Average= 2.89
(KJ/cycle)

Cycle 33 GMT 18/ 4/2018 15: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 18 15.30 3 1 0.00 / 94.92 3 3
2 7 1871.12 30 14.54 2793 1218 1.22 / 96.14 3 3
3 13 1352.28 16 14.72 2173 512 1.73 / 96.65 3 3
4 13 853.68 16 14.89 1505 359 2.09 / 97.01 3 3
5 13 192.04 16 15.18 599 145 2.23 / 97.15 3 3
6 13 39.96 16 15.25 363 89 2.32 / 97.24 3 3
7 8 0.16 180 15.23 296 811 3.13 / 98.05 3 3
Average= 2.88
(KJ/cycle)

Cycle 32 GMT 8/ 4/2018 14:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 18 15.30 3 1 0.00 / 91.79 3 3
2 7 1867.80 30 14.55 2785 1216 1.22 / 93.00 3 3
3 13 1358.64 13 14.73 2190 419 1.64 / 93.42 3 3
4 13 1028.44 13 14.83 1757 339 1.97 / 93.76 3 3
5 13 509.76 13 15.04 1047 205 2.18 / 93.96 3 3
6 13 85.68 13 15.24 431 85 2.26 / 94.05 3 3
7 13 20.72 13 15.27 329 65 2.33 / 94.11 3 3
8 8 0.08 180 15.23 293 803 3.13 / 94.92 3 3
Average= 2.88
(KJ/cycle)

Cycle 31 GMT 29/ 3/2018 14: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 18 15.30 2 1 0.00 / 88.67 3 3
2 7 1870.56 30 14.56 2794 1220 1.22 / 89.89 3 3
3 13 1347.84 13 14.74 2166 415 1.64 / 90.30 3 3
4 13 873.76 13 14.91 1534 297 1.93 / 90.60 3 3
5 13 543.76 13 15.03 1091 213 2.15 / 90.81 3 3
6 13 93.36 13 15.24 447 89 2.24 / 90.90 3 3
7 13 22.72 13 15.26 337 67 2.30 / 90.97 3 3
8 8 0.12 180 15.24 297 815 3.12 / 91.78 3 3
Average= 2.87
(KJ/cycle)

Cycle 30 GMT 19/ 3/2018 13:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 18 15.31 2 1 0.00 / 85.56 3 3
2 7 1868.20 30 14.57 2797 1223 1.22 / 86.78 3 3
3 13 1363.48 13 14.75 2191 420 1.64 / 87.20 3 3
4 13 899.80 13 14.89 1576 305 1.95 / 87.51 3 3
5 13 424.76 13 15.09 924 181 2.13 / 87.69 3 3
6 13 128.08 13 15.22 499 99 2.23 / 87.79 3 3
7 13 25.52 13 15.26 342 68 2.30 / 87.86 3 3
8 8 -0.04 180 15.23 296 811 3.11 / 88.67 3 3
Average= 2.86
(KJ/cycle)

Cycle 29 GMT 9/ 3/2018 13: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 18 15.31 2 1 0.00 / 82.44 3 3
2 3 1022.80 1 15.56 5 0 0.00 / 82.44 3 3
3 7 1867.76 30 14.56 2804 1225 1.23 / 83.66 3 3
4 13 1350.92 13 14.75 2179 418 1.64 / 84.08 3 3
5 13 873.44 13 14.91 1534 297 1.94 / 84.38 3 3
6 13 551.44 13 15.03 1105 216 2.16 / 84.60 3 3
7 13 94.48 13 15.24 449 89 2.25 / 84.68 3 3
8 13 21.08 13 15.27 336 67 2.31 / 84.75 3 3
9 8 0.12 180 15.24 295 809 3.12 / 85.56 3 3
Average= 2.85
(KJ/cycle)

Cycle 28 GMT 27/ 2/2018 12:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 19 15.31 2 1 0.00 / 79.32 3 3
2 3 971.96 -1 15.56 0 0 0.00 / 79.32 3 3
3 7 1866.96 30 14.57 2768 1210 1.21 / 80.53 3 3
4 13 1351.80 13 14.76 2167 416 1.63 / 80.95 3 3
5 13 1011.40 13 14.86 1723 333 1.96 / 81.28 3 3
6 13 498.56 13 15.06 1026 201 2.16 / 81.48 3 3
7 13 83.32 13 15.25 433 86 2.25 / 81.57 3 3
8 13 20.64 13 15.27 335 67 2.31 / 81.63 3 3
9 8 0.12 180 15.24 294 807 3.12 / 82.44 3 3
Average= 2.84
(KJ/cycle)

Cycle 27 GMT 17/ 2/2018 12: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 18 15.32 2 1 0.00 / 76.21 3 3
2 7 1862.52 30 14.57 2778 1214 1.21 / 77.43 3 3
3 13 1341.52 13 14.76 2161 415 1.63 / 77.84 3 3
4 13 867.60 13 14.92 1516 294 1.92 / 78.13 3 3
5 13 536.76 13 15.04 1085 212 2.14 / 78.35 3 3
6 13 95.12 13 15.24 451 89 2.23 / 78.44 3 3
7 13 19.80 13 15.27 335 67 2.29 / 78.50 3 3
8 8 0.16 180 15.24 298 817 3.11 / 79.32 3 3
Average= 2.83
(KJ/cycle)

Cycle 26 GMT 7/ 2/2018 11:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 18 15.32 2 1 0.00 / 73.17 3 3
2 7 1865.56 30 14.58 2765 1209 1.21 / 74.38 3 3
3 13 1352.68 13 14.77 2172 417 1.63 / 74.80 3 3
4 13 881.00 13 14.92 1543 299 1.93 / 75.10 3 3
5 13 543.28 13 15.04 1092 214 2.14 / 75.31 3 3
6 13 100.36 13 15.24 455 90 2.23 / 75.40 3 3
7 8 0.16 180 15.25 294 807 3.04 / 76.21 3 3
Average= 2.82
(KJ/cycle)

Cycle 25 GMT 28/ 1/2018 11: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 18 15.32 3 1 0.00 / 70.14 3 3
2 7 1863.68 30 14.58 2802 1226 1.23 / 71.37 3 3
3 13 1355.88 13 14.77 2182 419 1.65 / 71.79 3 3
4 13 891.04 13 14.91 1547 300 1.95 / 72.09 3 3
5 13 404.72 13 15.11 893 175 2.12 / 72.26 3 3
6 13 111.68 13 15.24 475 94 2.21 / 72.36 3 3
7 8 0.04 180 15.25 297 815 3.03 / 73.17 3 3
Average= 2.81
(KJ/cycle)

Cycle 24 GMT 18/ 1/2018 10:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 18 15.32 3 1 0.00 / 67.14 3 3
2 7 1862.28 30 14.59 2747 1202 1.20 / 68.35 3 3
3 13 1348.20 13 14.78 2163 416 1.62 / 68.76 3 3
4 13 868.96 13 14.93 1526 296 1.91 / 69.06 3 3
5 13 395.04 13 15.11 886 174 2.09 / 69.23 3 3
6 13 109.84 13 15.24 477 95 2.18 / 69.33 3 3
7 8 0.20 180 15.25 298 818 3.00 / 70.14 3 3
Average= 2.81
(KJ/cycle)

Cycle 23 GMT 8/ 1/2018 10: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 17 15.33 3 1 0.00 / 63.99 3 3
2 3 1028.96 1 15.57 3 0 0.00 / 63.99 3 3
3 7 1854.92 30 14.60 2772 1214 1.21 / 65.20 3 3
4 13 1354.20 13 14.78 2176 418 1.63 / 65.62 3 3
5 13 1025.64 13 14.87 1758 340 1.97 / 65.96 3 3
6 13 505.92 13 15.07 1038 203 2.18 / 66.16 3 3
7 13 85.48 13 15.26 438 87 2.26 / 66.25 3 3
8 13 17.80 13 15.28 337 67 2.33 / 66.32 3 3
9 8 -0.12 180 15.25 301 826 3.16 / 67.14 3 3
Average= 2.80
(KJ/cycle)

Cycle 22 GMT 29/12/2017 9:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 18 15.32 3 1 0.00 / 60.91 3 3
2 3 970.60 -1 15.58 0 0 0.00 / 60.91 3 3
3 7 1860.32 31 14.60 2774 1256 1.26 / 62.16 3 3
4 13 1355.48 13 14.78 2172 417 1.67 / 62.58 3 3
5 13 886.80 13 14.92 1558 302 1.98 / 62.88 3 3
6 13 400.72 13 15.12 891 175 2.15 / 63.06 3 3
7 13 114.40 13 15.25 484 96 2.25 / 63.15 3 3
8 8 0.12 180 15.25 303 832 3.08 / 63.99 3 3
Average= 2.78
(KJ/cycle)

Cycle 21 GMT 19/12/2017 8:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 18 15.33 3 1 0.00 / 57.91 3 3
2 7 1857.28 30 14.61 2754 1207 1.21 / 59.12 3 3
3 13 1336.12 13 14.80 2155 415 1.62 / 59.53 3 3
4 13 866.76 13 14.94 1529 297 1.92 / 59.83 3 3
5 13 389.20 13 15.12 880 173 2.09 / 60.00 3 3
6 13 60.20 13 15.28 400 79 2.17 / 60.08 3 3
7 8 0.00 180 15.26 300 824 3.00 / 60.91 3 3
Average= 2.77
(KJ/cycle)

Cycle 20 GMT 9/12/2017 8:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 18 15.33 3 1 0.00 / 54.85 3 3
2 7 1858.16 30 14.60 2812 1232 1.23 / 56.08 3 3
3 13 1330.08 13 14.79 2145 412 1.64 / 56.49 3 3
4 13 857.20 13 14.94 1514 294 1.94 / 56.78 3 3
5 13 524.48 13 15.07 1063 208 2.15 / 56.99 3 3
6 13 77.64 13 15.27 427 85 2.23 / 57.08 3 3
7 8 0.08 180 15.26 304 835 3.07 / 57.91 3 3
Average= 2.76
(KJ/cycle)

Cycle 19 GMT 29/11/2017 7:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 19 15.34 3 1 0.00 / 51.75 3 3
2 3 956.88 -1 15.59 0 0 0.00 / 51.75 3 3
3 7 1855.60 37 14.57 2782 1500 1.50 / 53.25 3 3
4 13 1136.16 14 14.86 1893 394 1.89 / 53.64 3 3
5 13 661.40 14 15.03 1246 262 2.16 / 53.90 3 3
6 13 169.12 14 15.23 566 121 2.28 / 54.02 3 3
7 8 0.00 180 15.27 299 822 3.10 / 54.84 3 3
Average= 2.74
(KJ/cycle)

Cycle 18 GMT 19/11/2017 7:23:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 19 15.34 4 1 0.00 / 48.64 3 3
2 7 1850.00 37 14.60 2743 1482 1.48 / 50.12 3 3
3 13 1111.24 14 14.87 1840 383 1.87 / 50.50 3 3
4 13 773.68 14 14.98 1403 294 2.16 / 50.79 3 3
5 13 137.32 14 15.25 515 110 2.27 / 50.90 3 3
6 8 0.12 180 15.27 306 841 3.11 / 51.75 3 3
Average= 2.72
(KJ/cycle)

Cycle 17 GMT 9/11/2017 7: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 18 15.34 4 1 0.00 / 45.55 3 3
2 3 1046.60 1 15.59 5 0 0.00 / 45.55 3 3
3 7 1852.48 37 14.60 2742 1481 1.48 / 47.03 3 3
4 13 1149.64 14 14.86 1886 392 1.87 / 47.43 3 3
5 13 656.56 14 15.03 1250 263 2.14 / 47.69 3 3
6 13 162.20 14 15.24 556 119 2.26 / 47.81 3 3
7 8 0.20 180 15.27 301 827 3.08 / 48.63 3 3
Average= 2.70
(KJ/cycle)

Cycle 16 GMT 30/10/2017 6:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 18 15.34 3 1 0.00 / 42.48 3 3
2 7 1849.48 37 14.59 2750 1485 1.49 / 43.96 3 3
3 13 1131.44 14 14.87 1859 387 1.87 / 44.35 3 3
4 13 645.68 14 15.04 1230 259 2.13 / 44.61 3 3
5 13 151.92 14 15.25 537 115 2.25 / 44.72 3 3
6 8 0.08 180 15.27 301 827 3.07 / 45.55 3 3
Average= 2.68
(KJ/cycle)

Cycle 15 GMT 20/10/2017 6:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 18 15.35 3 1 0.00 / 39.39 3 3
2 3 1021.88 1 15.59 5 0 0.00 / 39.39 3 3
3 7 1849.20 38 14.60 2725 1512 1.51 / 40.90 3 3
4 13 1120.52 14 14.87 1861 387 1.90 / 41.29 3 3
5 13 627.08 14 15.05 1207 254 2.15 / 41.54 3 3
6 13 157.32 14 15.25 542 116 2.27 / 41.66 3 3
7 8 0.28 180 15.28 297 817 3.09 / 42.48 3 3
Average= 2.65
(KJ/cycle)

Cycle 14 GMT 10/10/2017 6: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 17 15.34 4 1 0.00 / 36.33 3 3
2 3 1020.52 1 15.59 5 0 0.00 / 36.33 3 3
3 7 1846.20 37 14.60 2760 1491 1.49 / 37.82 3 3
4 13 1097.24 14 14.89 1837 383 1.88 / 38.21 3 3
5 13 603.52 14 15.06 1175 248 2.12 / 38.46 3 3
6 13 143.72 14 15.25 524 112 2.23 / 38.57 3 3
7 8 0.12 180 15.28 299 822 3.06 / 39.39 3 3
Average= 2.63
(KJ/cycle)

Cycle 13 GMT 30/ 9/2017 5:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 16 15.35 3 1 0.00 / 33.23 3 3
2 10 1012.76 3 15.53 5 0 0.00 / 33.23 3 3
3 3 953.24 -1 15.59 0 0 0.00 / 33.23 3 3
4 7 1833.32 38 14.60 2740 1520 1.52 / 34.75 3 3
5 13 1107.88 14 14.89 1845 385 1.91 / 35.14 3 3
6 13 609.64 14 15.06 1184 250 2.16 / 35.39 3 3
7 13 139.24 14 15.26 520 111 2.27 / 35.50 3 3
8 8 -0.08 180 15.28 304 836 3.10 / 36.33 3 3
Average= 2.60
(KJ/cycle)

Cycle 12 GMT 20/ 9/2017 5:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 24 15.37 4 1 0.00 / 30.18 3 3
2 3 682.08 -6 15.61 0 0 0.00 / 30.18 3 3
3 3 924.04 -1 15.63 0 0 0.00 / 30.18 3 3
4 7 1827.60 37 14.62 2736 1480 1.48 / 31.66 3 3
5 13 1116.44 14 14.90 1846 385 1.87 / 32.04 3 3
6 13 604.68 14 15.07 1178 249 2.12 / 32.29 3 3
7 13 130.60 14 15.27 506 108 2.22 / 32.40 3 3
8 8 0.12 180 15.28 303 833 3.06 / 33.23 3 3
Average= 2.56
(KJ/cycle)

Cycle 11 GMT 10/ 9/2017 5:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 18 15.37 3 1 0.00 / 27.41 3 3
2 7 1504.28 37 14.78 2364 1293 1.29 / 28.70 3 3
3 13 991.56 14 14.98 1695 355 1.65 / 29.06 3 3
4 13 369.84 14 15.20 852 181 1.83 / 29.24 3 3
5 13 97.32 14 15.31 457 98 1.93 / 29.34 3 3
6 8 0.04 180 15.30 304 837 2.77 / 30.17 3 3
Average= 2.51
(KJ/cycle)

Cycle 10 GMT 9/ 9/2017 6:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.40 17 15.37 3 1 0.00 / 24.60 3 3
2 10 1001.92 3 15.55 5 0 0.00 / 24.60 3 3
3 3 926.80 -1 15.60 0 0 0.00 / 24.60 3 3
4 3 966.56 -1 15.63 0 0 0.00 / 24.60 3 3
5 7 1515.44 37 14.78 2366 1294 1.29 / 25.90 3 3
6 13 1003.96 14 14.97 1714 359 1.65 / 26.26 3 3
7 13 507.20 14 15.14 1038 220 1.87 / 26.48 3 3
8 13 76.24 14 15.31 423 91 1.96 / 26.57 3 3
9 8 0.04 180 15.30 305 840 2.80 / 27.41 3 3
Average= 2.49
(KJ/cycle)

Cycle 9 GMT 8/ 9/2017 8:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 24 15.41 3 1 0.00 / 21.80 3 3
2 3 739.64 -5 15.62 0 0 0.00 / 21.80 3 3
3 3 938.92 -1 15.64 0 0 0.00 / 21.80 3 3
4 7 1505.48 37 14.79 2362 1293 1.29 / 23.09 3 3
5 13 999.88 14 14.98 1702 357 1.65 / 23.45 3 3
6 13 512.44 14 15.14 1045 221 1.87 / 23.67 3 3
7 13 83.36 14 15.31 435 93 1.97 / 23.76 3 3
8 8 0.04 180 15.30 305 840 2.81 / 24.60 3 3
Average= 2.46
(KJ/cycle)

Cycle 8 GMT 7/ 9/2017 10: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 18 15.41 3 1 0.00 / 19.91 3 3
2 7 1000.96 37 14.99 1685 935 0.94 / 20.84 3 3
3 13 111.92 14 15.35 483 104 1.04 / 20.95 3 3
4 8 0.20 180 15.34 308 850 1.89 / 21.80 3 3
Average= 2.42
(KJ/cycle)

Cycle 7 GMT 6/ 9/2017 22:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 17 15.41 5 1 0.00 / 18.05 3 3
2 10 1001.88 3 15.56 6 0 0.00 / 18.05 3 3
3 3 938.56 -1 15.59 0 0 0.00 / 18.05 3 3
4 7 969.68 37 15.01 1647 915 0.92 / 18.96 3 3
5 13 94.20 14 15.36 453 97 1.01 / 19.06 3 3
6 8 0.16 180 15.35 307 848 1.86 / 19.91 3 3
Average= 2.49
(KJ/cycle)

Cycle 6 GMT 6/ 9/2017 11:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 16 15.37 4 1 0.00 / 16.30 3 3
2 3 1033.80 1 15.58 6 0 0.00 / 16.30 3 3
3 7 1009.08 37 14.98 1690 937 0.94 / 17.23 3 3
4 13 116.80 14 15.34 489 105 1.04 / 17.34 3 3
5 8 0.04 150 15.34 308 709 1.75 / 18.05 3 3
Average= 2.58
(KJ/cycle)

Cycle 5 GMT 6/ 9/2017 0:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 17 15.36 4 1 0.00 / 13.33 3 3
2 3 955.64 -1 15.58 0 0 0.00 / 13.33 3 3
3 7 991.96 74 14.92 1647 1818 1.82 / 15.15 3 3
4 8 0.08 240 15.29 312 1145 2.96 / 16.29 3 3
Average= 2.72
(KJ/cycle)

Cycle 4 GMT 5/ 9/2017 14: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 17 15.36 4 1 0.00 / 10.34 3 3
2 7 1006.12 74 14.91 1672 1845 1.85 / 12.19 3 3
3 8 -0.04 240 15.29 311 1141 2.99 / 13.33 3 3
Average= 2.67
(KJ/cycle)

Cycle 3 GMT 5/ 9/2017 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 17 15.36 3 1 0.00 / 7.36 3 3
2 7 993.56 74 14.91 1656 1827 1.83 / 9.19 3 3
3 8 -0.04 240 15.28 314 1152 2.98 / 10.34 3 4
Average= 2.59
(KJ/cycle)

Cycle 2 GMT 4/ 9/2017 17: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 16 15.37 4 1 0.00 / 4.40 3 3
2 10 1000.68 3 15.54 7 0 0.00 / 4.40 3 3
3 3 939.56 -1 15.57 0 0 0.00 / 4.40 3 3
4 7 975.40 74 14.93 1634 1805 1.81 / 6.21 3 3
5 8 0.04 240 15.28 316 1159 2.97 / 7.36 3 3
Average= 2.45
(KJ/cycle)

Cycle 1 GMT 4/ 9/2017 6:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 24 15.55 4 1 0.00 / 1.41 3 3
2 3 707.68 -6 15.62 0 0 0.00 / 1.41 3 3
3 3 955.28 -1 15.63 0 0 0.00 / 1.41 3 3
4 7 990.28 74 14.93 1652 1825 1.83 / 3.24 3 3
5 8 0.00 240 15.29 317 1163 2.99 / 4.40 3 3
Average= 2.20
(KJ/cycle)

Cycle 0 GMT 3/ 9/2017 19:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 58.84 24 15.70 4 2 0.00 / 0.00 3 3
2 7 71.32 74 15.59 369 426 0.43 / 0.43 3 3
3 8 0.36 240 15.55 263 982 1.41 / 1.41 3 17
Average= 1.41
(KJ/cycle)