SIO Argo Site:
Pump Diagnostics Page   



Serial= 8521 WMO= 5902511

Return

←PreviousNext→

Cycle 288 GMT 2/12/2023 8:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 32 10.78 404 139 0.14 / 1466.16 2 2
2 12 1119.80 115 8.09 1860 1730 1.87 / 1467.89 2 2
3 7 1113.80 25 8.14 1861 379 2.25 / 1468.27 2 2
4 13 549.32 48 9.45 1079 489 2.74 / 1468.76 2 2
5 13 105.76 48 10.60 418 213 2.95 / 1468.97 2 2
6 8 -0.04 160 10.90 250 436 3.39 / 1469.40 2 2
Average= 5.08 (KJ/cycle)

Cycle 287 GMT 22/11/2023 14:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 37 10.80 408 163 0.16 / 1462.71 2 2
2 3 867.56 -2 11.55 0 0 0.00 / 1462.71 2 2
3 3 1027.24 1 8.70 1744 15 0.18 / 1462.73 2 2
4 12 1137.20 115 8.17 1887 1773 1.95 / 1464.50 2 2
5 7 1131.84 24 8.27 1883 374 2.32 / 1464.87 2 2
6 13 555.04 48 9.50 1093 498 2.82 / 1465.37 2 2
7 13 125.76 48 10.61 439 224 3.05 / 1465.60 2 2
8 8 0.20 160 10.94 241 422 3.47 / 1466.02 2 2
Average= 5.09 (KJ/cycle)

Cycle 286 GMT 12/11/2023 20:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 48 10.83 401 208 0.21 / 1459.75 2 2
2 3 567.20 -6 11.55 0 0 0.00 / 1459.75 2 2
3 3 849.16 -2 11.55 0 0 0.00 / 1459.75 2 2
4 12 1090.80 115 8.39 1834 1770 1.98 / 1461.52 2 2
5 7 1082.88 24 8.51 1820 372 2.35 / 1461.89 2 2
6 13 107.20 48 10.68 416 213 2.56 / 1462.11 2 2
7 8 0.28 160 10.94 253 443 3.01 / 1462.55 2 2
Average= 5.10 (KJ/cycle)

Cycle 285 GMT 7/11/2023 4:19:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 34 10.83 406 149 0.15 / 1453.87 2 2
2 3 923.20 -1 11.55 0 0 0.00 / 1453.87 2 2
3 12 1120.16 4 8.58 1868 64 0.21 / 1453.94 2 2
4 12 1997.76 115 6.79 3146 2457 2.67 / 1456.39 2 2
5 7 1992.16 24 6.50 3392 529 3.20 / 1456.92 2 2
6 13 1594.28 48 7.67 2520 928 4.13 / 1457.85 2 2
7 13 1044.68 48 8.67 1766 735 4.86 / 1458.58 2 2
8 13 305.36 48 10.17 743 363 5.22 / 1458.95 2 2
9 13 39.48 48 10.88 306 160 5.38 / 1459.11 2 2
10 8 -0.40 160 10.96 249 437 5.82 / 1459.54 2 2
Average= 5.10 (KJ/cycle)

Cycle 284 GMT 6/11/2023 1: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 32 10.84 406 141 0.14 / 1450.43 2 2
2 12 1091.56 115 8.55 1828 1797 1.94 / 1452.23 2 2
3 7 1085.36 24 8.60 1828 377 2.32 / 1452.60 2 2
4 13 509.64 48 9.76 1023 479 2.79 / 1453.08 2 2
5 13 91.16 48 10.75 391 202 3.00 / 1453.29 2 2
6 8 0.12 160 10.96 249 437 3.43 / 1453.72 2 2
Average= 5.10 (KJ/cycle)

Cycle 283 GMT 27/10/2023 7:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 80 10.78 420 362 0.36 / 1447.10 2 2
2 3 155.08 -11 11.53 0 0 0.00 / 1447.10 2 2
3 3 466.24 -7 11.56 0 0 0.00 / 1447.10 2 2
4 12 1069.60 115 8.66 1793 1786 2.15 / 1448.89 2 2
5 7 1063.44 24 8.75 1792 376 2.52 / 1449.26 2 2
6 13 349.24 48 10.14 791 385 2.91 / 1449.65 2 2
7 13 89.40 48 10.76 388 200 3.11 / 1449.85 2 2
8 8 0.12 160 10.97 251 441 3.55 / 1450.29 2 2
Average= 5.11 (KJ/cycle)

Cycle 282 GMT 17/10/2023 13:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 2051.44 17 5.97 3258 331 0.33 / 1439.22 2 2
2 3 2052.36 26 6.00 3391 529 0.86 / 1439.75 2 2
3 3 1993.44 25 6.07 3442 522 1.38 / 1440.27 2 2
4 12 1978.08 115 6.36 3179 2325 3.71 / 1442.60 2 2
5 7 1973.16 24 6.05 3264 474 4.18 / 1443.07 2 2
6 13 1869.84 48 6.84 2902 953 5.13 / 1444.02 2 2
7 13 1746.72 48 7.09 2736 931 6.06 / 1444.96 2 2
8 13 1153.44 48 8.32 1915 765 6.83 / 1445.72 2 2
9 13 398.48 48 9.93 864 412 7.24 / 1446.13 2 2
10 13 32.92 48 10.87 303 158 7.40 / 1446.29 2 2
11 8 0.08 160 10.94 256 448 7.85 / 1446.74 2 2
Average= 5.11 (KJ/cycle)

Cycle 281

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 27 11.01 413 123 0.12 / 1408.46 2 2
2 10 1038.24 4 8.51 1741 59 0.18 / 1408.52 2 2
3 3 1088.84 2 8.19 1842 30 0.21 / 1408.55 2 2
4 3 1058.08 1 8.49 1776 15 0.23 / 1408.57 2 2
5 12 1144.72 4 8.17 1910 62 0.29 / 1408.63 2 2
6 12 2006.68 115 5.72 2461 1619 1.91 / 1410.25 2 2
7 7 2007.80 24 5.76 2214 306 2.21 / 1410.55 2 2
8 13 2028.04 48 5.80 2494 694 2.91 / 1411.25 2 2
9 13 2045.04 48 5.82 2555 714 3.62 / 1411.96 2 2
10 13 2055.48 48 5.83 2610 730 4.35 / 1412.69 2 2
11 13 2048.16 48 5.84 2666 747 5.10 / 1413.44 2 2
12 13 2037.16 48 5.86 2711 763 5.86 / 1414.20 2 2
13 13 2039.68 48 5.89 2742 775 6.64 / 1414.98 2 2
14 13 2049.56 48 5.87 2781 784 7.42 / 1415.76 2 2
15 13 2045.68 48 5.88 2803 791 8.21 / 1416.55 2 2
16 13 2042.72 48 5.88 2832 799 9.01 / 1417.35 2 2
17 13 2043.20 48 5.89 2865 810 9.82 / 1418.16 2 2
18 13 2041.00 48 5.89 2899 820 10.64 / 1418.98 2 2
19 13 2044.72 48 5.91 2926 830 11.47 / 1419.81 2 2
20 13 2046.32 48 5.91 2956 839 12.31 / 1420.65 2 2
21 13 2042.72 48 5.92 2985 848 13.16 / 1421.50 2 2
22 13 2039.48 48 5.93 3008 856 14.01 / 1422.36 2 2
23 13 2035.76 48 5.93 3037 864 14.88 / 1423.22 2 2
24 13 2036.08 48 5.94 3057 872 15.75 / 1424.09 2 2
25 13 2040.24 48 5.97 3075 881 16.63 / 1424.97 2 2
26 13 2042.48 48 5.96 3101 887 17.52 / 1425.86 2 2
27 13 2039.84 48 5.95 3129 894 18.41 / 1426.75 2 2
28 13 2043.28 48 5.95 3144 898 19.31 / 1427.65 2 2
29 13 2045.16 48 5.96 3166 906 20.22 / 1428.56 2 2
30 13 2048.76 48 5.97 3183 912 21.13 / 1429.47 2 2
31 13 2052.20 48 6.00 3192 919 22.05 / 1430.39 2 2
32 13 2045.88 48 5.99 3252 935 22.98 / 1431.32 2 2
33 13 2042.88 48 6.02 3262 943 23.93 / 1432.27 2 2
34 13 2041.60 48 6.00 3292 948 24.87 / 1433.21 2 2
35 13 2043.48 48 6.00 3309 953 25.83 / 1434.17 2 2
36 13 2043.96 48 6.01 3323 959 26.79 / 1435.13 2 2
37 13 2042.72 48 6.01 3337 963 27.75 / 1436.09 2 2
38 8 2042.48 160 5.82 3010 2803 30.55 / 1438.89 2 2
Average= 5.10 (KJ/cycle)

Cycle 280 GMT 15/10/2023 16:14: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 25 11.27 408 115 0.11 / 1404.09 2 2
2 10 1023.08 4 9.23 1737 64 0.18 / 1404.15 2 2
3 3 1103.60 3 8.95 1845 50 0.23 / 1404.20 2 2
4 3 1061.44 2 8.93 1820 33 0.26 / 1404.24 2 2
5 12 1169.24 115 5.96 1903 1304 1.57 / 1405.54 2 2
6 7 1172.40 24 6.61 1930 306 1.87 / 1405.85 2 2
7 13 1198.40 48 6.79 1954 637 2.51 / 1406.48 2 2
8 13 1096.00 48 7.31 1812 636 3.14 / 1407.12 2 2
9 13 696.68 48 8.67 1278 532 3.68 / 1407.65 2 2
10 13 138.84 48 10.60 474 241 3.92 / 1407.89 2 2
11 8 0.20 160 11.09 252 447 4.36 / 1408.34 2 2
Average= 5.01 (KJ/cycle)

Cycle 279 GMT 5/10/2023 23: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 28 11.64 420 137 0.14 / 1400.23 2 2
2 3 1033.32 1 9.66 1782 17 0.15 / 1400.24 2 2
3 3 1025.24 1 9.46 1762 17 0.17 / 1400.26 2 2
4 12 1153.12 115 6.21 1865 1332 1.50 / 1401.59 2 2
5 7 1152.12 24 6.90 1904 315 1.82 / 1401.91 2 2
6 13 1070.20 48 7.83 1790 673 2.49 / 1402.58 2 2
7 13 945.52 48 8.43 1611 652 3.14 / 1403.23 2 2
8 13 180.76 48 10.71 543 279 3.42 / 1403.51 2 2
9 8 0.12 160 11.29 257 464 3.89 / 1403.98 2 2
Average= 5.01 (KJ/cycle)

Cycle 278 GMT 26/ 9/2023 4:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 24 12.43 420 125 0.13 / 1396.56 2 2
2 10 1016.20 4 11.33 1770 80 0.21 / 1396.64 2 2
3 3 1024.84 1 10.87 1800 20 0.23 / 1396.66 2 2
4 12 1133.92 115 8.25 1887 1790 2.02 / 1398.45 2 2
5 7 1127.52 25 8.55 1879 402 2.42 / 1398.86 2 2
6 13 578.72 48 10.22 1124 551 2.97 / 1399.41 2 2
7 13 68.68 48 11.57 362 201 3.17 / 1399.61 2 2
8 8 0.12 160 11.70 257 481 3.65 / 1400.09 2 2
Average= 5.02 (KJ/cycle)

Cycle 277 GMT 16/ 9/2023 10:47:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 23 12.72 426 125 0.12 / 1391.10 2 2
2 10 1009.48 3 11.63 1765 62 0.19 / 1391.16 2 2
3 3 1032.96 1 11.26 1806 20 0.21 / 1391.18 2 2
4 3 1024.00 1 11.17 1799 20 0.23 / 1391.20 2 2
5 12 1126.96 4 11.27 1932 87 0.31 / 1391.29 2 2
6 12 1991.72 115 8.23 3095 2929 3.24 / 1394.21 2 2
7 7 1984.44 24 8.33 3072 614 3.86 / 1394.83 2 2
8 13 818.76 48 10.56 1476 748 4.61 / 1395.58 2 2
9 13 201.96 48 11.87 593 338 4.94 / 1395.91 2 2
10 8 0.40 160 12.33 266 525 5.47 / 1396.44 2 2
Average= 5.02 (KJ/cycle)

Cycle 276 GMT 15/ 9/2023 7:22: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 23 13.44 428 132 0.13 / 1386.08 2 2
2 3 1063.68 2 11.77 1868 44 0.18 / 1386.12 2 2
3 12 1145.32 115 5.59 1864 1198 1.37 / 1387.32 2 2
4 7 1150.84 24 9.11 1940 424 1.80 / 1387.75 2 2
5 13 1247.56 48 8.26 2051 813 2.61 / 1388.56 2 2
6 13 1173.00 48 8.84 1957 830 3.44 / 1389.39 2 2
7 13 899.84 48 9.99 1589 762 4.20 / 1390.15 2 2
8 13 132.56 48 12.29 477 281 4.49 / 1390.43 2 2
9 8 -0.08 160 12.56 268 539 5.02 / 1390.97 2 2
Average= 5.02 (KJ/cycle)

Cycle 275 GMT 5/ 9/2023 12:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 23 13.93 426 136 0.14 / 1381.13 2 2
2 3 1023.64 1 11.63 1803 21 0.16 / 1381.15 2 2
3 12 1123.04 115 5.54 1653 1053 1.21 / 1382.21 2 2
4 7 1128.20 24 9.32 1901 425 1.64 / 1382.63 2 2
5 13 1203.76 48 8.03 1992 768 2.40 / 1383.40 2 2
6 13 1127.16 48 8.98 1889 814 3.22 / 1384.21 2 2
7 13 995.28 48 9.86 1715 812 4.03 / 1385.02 2 2
8 13 178.20 48 12.65 565 343 4.37 / 1385.37 2 2
9 8 -0.12 160 13.17 275 579 4.95 / 1385.95 2 2
Average= 5.02 (KJ/cycle)

Cycle 274 GMT 26/ 8/2023 18: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 23 14.22 430 141 0.14 / 1376.13 2 2
2 12 1124.84 115 5.58 1877 1204 1.35 / 1377.34 2 2
3 7 1130.08 24 9.77 1903 446 1.79 / 1377.78 2 2
4 13 1200.72 48 8.99 1990 859 2.65 / 1378.64 2 2
5 13 1114.44 48 9.70 1881 876 3.53 / 1379.52 2 2
6 13 539.84 48 12.07 1099 637 4.16 / 1380.15 2 2
7 13 47.64 48 13.76 347 229 4.39 / 1380.38 2 2
8 8 0.00 160 13.74 279 613 5.01 / 1381.00 2 2
Average= 5.02 (KJ/cycle)

Cycle 273 GMT 16/ 8/2023 23:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 23 14.19 423 138 0.14 / 1370.30 2 2
2 12 1080.36 4 11.27 1874 84 0.22 / 1370.38 2 2
3 12 1995.16 115 7.85 3092 2791 3.01 / 1373.18 2 2
4 7 1988.04 24 9.59 3088 711 3.72 / 1373.89 2 2
5 13 1050.08 48 11.88 1807 1030 4.75 / 1374.92 2 2
6 13 218.92 48 13.61 649 424 5.18 / 1375.34 2 2
7 8 -0.04 160 14.13 287 649 5.83 / 1375.99 2 2
Average= 5.02 (KJ/cycle)

Cycle 272 GMT 15/ 8/2023 19:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 23 14.22 426 139 0.14 / 1365.30 2 2
2 12 1128.00 115 5.52 1575 1000 1.14 / 1366.30 2 2
3 7 1133.20 24 9.22 1919 425 1.56 / 1366.73 2 2
4 13 1229.80 48 8.46 2016 819 2.38 / 1367.55 2 2
5 13 1159.08 48 9.47 1927 876 3.26 / 1368.42 2 2
6 13 750.88 48 11.77 1404 793 4.05 / 1369.21 2 2
7 13 118.20 48 13.89 468 312 4.36 / 1369.53 2 2
8 8 -0.24 160 14.18 280 635 5.00 / 1370.16 2 2
Average= 5.02 (KJ/cycle)

Cycle 271 GMT 6/ 8/2023 0:56: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 23 14.24 428 140 0.14 / 1360.21 2 2
2 12 1159.08 115 5.53 1641 1044 1.18 / 1361.25 2 2
3 7 1164.20 24 9.29 1950 435 1.62 / 1361.69 2 2
4 13 1251.36 48 8.65 2055 853 2.47 / 1362.54 2 2
5 13 1177.32 48 9.74 1966 919 3.39 / 1363.46 2 2
6 13 745.52 48 12.00 1395 804 4.19 / 1364.27 2 2
7 13 57.20 48 14.07 371 251 4.45 / 1364.52 2 2
8 8 0.12 160 14.20 285 648 5.09 / 1365.16 2 2
Average= 5.02 (KJ/cycle)

Cycle 270 GMT 27/ 7/2023 6:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 23 14.28 429 141 0.14 / 1356.28 2 2
2 12 1133.40 115 6.41 1859 1370 1.51 / 1357.65 2 2
3 7 1132.00 24 9.98 1906 457 1.97 / 1358.10 2 2
4 13 1008.76 48 10.57 1733 879 2.85 / 1358.98 2 2
5 13 255.76 48 13.46 687 444 3.29 / 1359.43 2 2
6 8 -0.16 160 14.20 283 643 3.93 / 1360.07 2 2
Average= 5.02 (KJ/cycle)

Cycle 269 GMT 17/ 7/2023 12:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 23 14.19 431 141 0.14 / 1350.43 2 2
2 12 1112.72 4 11.11 1911 85 0.23 / 1350.52 2 2
3 12 1994.36 115 8.30 3104 2963 3.19 / 1353.48 2 2
4 7 1987.56 24 9.88 3120 740 3.93 / 1354.22 2 2
5 13 907.36 48 12.56 1598 963 4.89 / 1355.18 2 2
6 13 110.48 48 14.01 459 309 5.20 / 1355.49 2 2
7 8 -0.16 160 14.28 282 644 5.84 / 1356.14 2 2
Average= 5.02 (KJ/cycle)

Cycle 268 GMT 16/ 7/2023 8:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 23 14.20 432 141 0.14 / 1345.55 2 2
2 12 1140.16 115 5.54 1685 1074 1.21 / 1346.62 2 2
3 7 1145.04 24 9.60 1931 445 1.66 / 1347.07 2 2
4 13 1219.92 48 9.72 2026 945 2.60 / 1348.01 2 2
5 13 1116.60 48 10.60 1885 959 3.56 / 1348.97 2 2
6 13 519.96 48 12.82 1080 665 4.23 / 1349.64 2 2
7 8 0.28 160 14.21 288 655 4.88 / 1350.29 2 2
Average= 5.02 (KJ/cycle)

Cycle 267 GMT 6/ 7/2023 14:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 24 14.23 440 150 0.15 / 1340.60 2 2
2 12 1117.88 115 5.56 1751 1120 1.27 / 1341.72 2 2
3 7 1123.08 24 9.72 1901 443 1.71 / 1342.17 2 2
4 13 1201.84 48 9.93 2009 958 2.67 / 1343.12 2 2
5 13 1100.52 48 10.75 1874 967 3.64 / 1344.09 2 2
6 13 505.96 48 12.88 1061 656 4.29 / 1344.75 2 2
7 8 -0.12 160 14.20 292 663 4.96 / 1345.41 2 2
Average= 5.02 (KJ/cycle)

Cycle 266 GMT 26/ 6/2023 19:52: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 24 14.29 435 149 0.15 / 1336.47 2 2
2 3 953.92 -1 15.08 0 0 0.00 / 1336.47 2 2
3 3 1027.16 1 11.18 1815 20 0.17 / 1336.49 2 2
4 12 1154.64 115 6.63 1896 1446 1.62 / 1337.94 2 2
5 7 1152.20 24 10.18 1943 475 2.09 / 1338.41 2 2
6 13 1027.68 48 11.30 1774 962 3.05 / 1339.37 2 2
7 13 228.04 48 13.64 649 425 3.48 / 1339.80 2 2
8 8 0.44 160 14.25 286 652 4.13 / 1340.45 2 2
Average= 5.02 (KJ/cycle)

Cycle 265 GMT 17/ 6/2023 1:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 23 14.21 435 142 0.14 / 1330.61 2 2
2 12 1101.00 4 11.19 1886 84 0.23 / 1330.69 2 2
3 12 1990.16 115 8.32 3104 2970 3.20 / 1333.66 2 2
4 7 1982.56 24 10.06 3096 747 3.94 / 1334.41 2 2
5 13 863.92 48 12.74 1564 956 4.90 / 1335.37 2 2
6 13 85.72 48 14.07 428 289 5.19 / 1335.66 2 2
7 8 0.28 160 14.30 291 666 5.86 / 1336.32 2 2
Average= 5.02 (KJ/cycle)

Cycle 264 GMT 15/ 6/2023 22:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 23 14.20 432 141 0.14 / 1325.71 2 2
2 12 1141.36 115 5.55 1718 1097 1.24 / 1326.81 2 2
3 7 1146.80 24 9.68 1937 450 1.69 / 1327.26 2 2
4 13 1229.76 48 10.15 2041 994 2.68 / 1328.25 2 2
5 13 1128.60 48 10.89 1909 998 3.68 / 1329.25 2 2
6 13 368.68 48 13.30 868 554 4.23 / 1329.81 2 2
7 8 -0.04 160 14.22 291 662 4.90 / 1330.47 2 2
Average= 5.02 (KJ/cycle)

Cycle 263 GMT 6/ 6/2023 4:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 22 14.19 439 137 0.14 / 1320.69 2 2
2 3 1049.52 1 11.45 1813 21 0.16 / 1320.71 2 2
3 3 1022.48 1 10.63 1829 19 0.18 / 1320.73 2 2
4 12 1145.12 115 5.58 1781 1143 1.32 / 1321.87 2 2
5 7 1150.76 24 9.81 1944 458 1.78 / 1322.33 2 2
6 13 1236.84 48 10.28 2059 1016 2.79 / 1323.35 2 2
7 13 1121.20 48 11.00 1904 1005 3.80 / 1324.35 2 2
8 13 359.40 48 13.33 856 548 4.35 / 1324.90 2 2
9 8 -0.04 160 14.19 296 672 5.02 / 1325.57 2 2
Average= 5.02 (KJ/cycle)

Cycle 262 GMT 27/ 5/2023 9:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 23 14.24 429 141 0.14 / 1316.79 2 2
2 12 1112.08 115 7.07 1828 1486 1.63 / 1318.27 2 2
3 7 1107.68 24 10.35 1882 467 2.09 / 1318.74 2 2
4 13 822.00 48 12.22 1499 879 2.97 / 1319.62 2 2
5 13 77.12 48 14.01 406 273 3.25 / 1319.89 2 2
6 8 -0.32 160 14.22 290 660 3.91 / 1320.55 2 2
Average= 5.02 (KJ/cycle)

Cycle 261 GMT 17/ 5/2023 15:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 24 14.18 432 147 0.15 / 1310.98 2 2
2 3 952.44 -1 15.08 0 0 0.00 / 1310.98 2 2
3 3 1018.88 1 10.63 1824 19 0.17 / 1311.00 2 2
4 12 1110.32 4 11.13 1907 85 0.25 / 1311.09 2 2
5 12 1997.64 115 8.25 3113 2953 3.20 / 1314.04 2 2
6 7 1991.00 24 10.14 3124 760 3.97 / 1314.80 2 2
7 13 791.84 48 12.89 1470 910 4.87 / 1315.71 2 2
8 13 61.16 48 14.09 388 262 5.14 / 1315.97 2 2
9 8 -0.04 160 14.25 295 673 5.81 / 1316.65 2 2
Average= 5.03 (KJ/cycle)

Cycle 260 GMT 16/ 5/2023 12:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 24 14.15 436 148 0.15 / 1306.16 2 2
2 12 1114.96 115 5.56 1753 1121 1.27 / 1307.28 2 2
3 7 1120.84 24 9.97 1898 454 1.72 / 1307.74 2 2
4 13 1206.52 48 10.67 2016 1033 2.76 / 1308.77 2 2
5 13 1092.60 48 11.25 1854 1001 3.76 / 1309.77 2 2
6 13 187.04 48 13.75 593 391 4.15 / 1310.16 2 2
7 8 0.12 160 14.19 298 677 4.82 / 1310.84 2 2
Average= 5.02 (KJ/cycle)

Cycle 259 GMT 6/ 5/2023 18: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 23 14.18 428 140 0.14 / 1301.11 2 2
2 12 1146.16 115 5.56 1774 1134 1.27 / 1302.25 2 2
3 7 1152.16 24 9.89 1954 464 1.74 / 1302.71 2 2
4 13 1242.44 48 10.43 2075 1039 2.78 / 1303.75 2 2
5 13 1130.20 48 11.11 1913 1020 3.80 / 1304.77 2 2
6 13 350.00 48 13.38 851 547 4.34 / 1305.32 2 2
7 8 0.12 160 14.19 306 695 5.04 / 1306.01 2 2
Average= 5.02 (KJ/cycle)

Cycle 258 GMT 26/ 4/2023 23:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 23 14.21 427 140 0.14 / 1297.10 2 2
2 12 1111.44 115 6.98 1839 1476 1.62 / 1298.58 2 2
3 7 1108.00 25 10.42 1881 490 2.11 / 1299.07 2 2
4 13 980.40 48 11.85 1711 973 3.08 / 1300.04 2 2
5 13 72.48 48 14.02 406 273 3.35 / 1300.31 2 2
6 8 -0.16 160 14.23 290 660 4.01 / 1300.97 2 2
Average= 5.02 (KJ/cycle)

Cycle 257 GMT 17/ 4/2023 5:44: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 23 14.16 441 144 0.14 / 1291.11 2 2
2 3 1028.68 1 11.19 1799 20 0.16 / 1291.13 2 2
3 3 1020.60 1 10.68 1824 19 0.18 / 1291.15 2 2
4 12 1124.32 4 11.12 1931 86 0.27 / 1291.24 2 2
5 12 1991.24 115 8.18 3105 2921 3.19 / 1294.16 2 2
6 7 1984.04 24 10.24 3100 762 3.95 / 1294.92 2 2
7 13 1050.48 48 12.58 1793 1083 5.03 / 1296.00 2 2
8 13 91.24 48 14.04 438 295 5.33 / 1296.30 2 2
9 8 0.24 160 14.25 292 666 6.00 / 1296.96 2 2
Average= 5.03 (KJ/cycle)

Cycle 256 GMT 16/ 4/2023 2:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 24 14.14 426 145 0.14 / 1286.17 2 2
2 3 958.28 -1 15.07 0 0 0.00 / 1286.17 2 2
3 3 1035.36 1 11.14 1807 20 0.16 / 1286.19 2 2
4 12 1150.12 115 5.56 1760 1125 1.29 / 1287.32 2 2
5 7 1155.16 24 10.06 1952 471 1.76 / 1287.79 2 2
6 13 1236.76 48 10.87 2055 1072 2.83 / 1288.86 2 2
7 13 1122.96 48 11.39 1894 1035 3.87 / 1289.90 2 2
8 13 208.60 48 13.74 621 410 4.28 / 1290.31 2 2
9 8 0.04 160 14.20 290 659 4.94 / 1290.97 2 2
Average= 5.02 (KJ/cycle)

Cycle 255 GMT 6/ 4/2023 7:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 23 14.14 427 139 0.14 / 1281.39 2 2
2 12 1127.12 115 5.55 1690 1079 1.22 / 1282.47 2 2
3 7 1132.60 24 9.85 1922 454 1.67 / 1282.92 2 2
4 13 1218.00 48 10.49 2036 1025 2.70 / 1283.95 2 2
5 13 1108.64 48 11.20 1869 1005 3.70 / 1284.95 2 2
6 13 213.80 48 13.71 631 415 4.12 / 1285.37 2 2
7 8 0.40 160 14.19 292 663 4.78 / 1286.03 2 2
Average= 5.02 (KJ/cycle)

Cycle 254 GMT 27/ 3/2023 13:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 23 14.17 434 141 0.14 / 1277.39 2 2
2 12 1093.96 115 6.94 1803 1439 1.58 / 1278.83 2 2
3 7 1090.16 24 10.50 1856 468 2.05 / 1279.30 2 2
4 13 957.68 48 11.96 1679 964 3.01 / 1280.26 2 2
5 13 133.40 48 13.90 498 332 3.34 / 1280.59 2 2
6 8 0.28 160 14.21 289 657 4.00 / 1281.25 2 2
Average= 5.02 (KJ/cycle)

Cycle 253 GMT 17/ 3/2023 19:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 23 14.14 431 140 0.14 / 1271.57 2 2
2 12 1105.84 4 11.22 1897 85 0.23 / 1271.66 2 2
3 12 1988.20 115 8.00 3091 2844 3.07 / 1274.50 2 2
4 7 1981.16 24 10.24 3112 765 3.83 / 1275.27 2 2
5 13 922.92 48 12.78 1621 994 4.83 / 1276.26 2 2
6 13 103.16 48 14.02 460 310 5.14 / 1276.57 2 2
7 8 0.16 160 14.24 297 677 5.81 / 1277.25 2 2
Average= 5.03 (KJ/cycle)

Cycle 252 GMT 16/ 3/2023 15:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 23 14.12 445 145 0.14 / 1266.60 2 2
2 3 1025.44 1 11.02 1794 20 0.16 / 1266.62 2 2
3 12 1147.64 115 5.57 1773 1136 1.30 / 1267.75 2 2
4 7 1152.88 24 10.16 1958 477 1.78 / 1268.23 2 2
5 13 1227.60 48 11.09 2057 1095 2.87 / 1269.33 2 2
6 13 1110.76 48 11.59 1892 1053 3.92 / 1270.38 2 2
7 13 184.00 48 13.81 587 389 4.31 / 1270.77 2 2
8 8 0.40 160 14.22 292 664 4.98 / 1271.43 2 2
Average= 5.03 (KJ/cycle)

Cycle 251 GMT 6/ 3/2023 21:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 23 14.11 436 141 0.14 / 1261.78 2 2
2 12 1126.64 115 5.55 1719 1097 1.24 / 1262.88 2 2
3 7 1131.88 24 10.06 1924 465 1.70 / 1263.34 2 2
4 13 1207.80 48 10.85 2019 1051 2.75 / 1264.40 2 2
5 13 1095.04 48 11.40 1864 1020 3.77 / 1265.42 2 2
6 13 166.28 48 13.80 568 376 4.15 / 1265.79 2 2
7 8 -0.08 160 14.19 292 663 4.81 / 1266.45 2 2
Average= 5.03 (KJ/cycle)

Cycle 250 GMT 25/ 2/2023 2:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 23 14.14 433 141 0.14 / 1257.82 2 2
2 12 1091.40 115 6.89 1803 1429 1.57 / 1259.25 2 2
3 7 1089.12 24 10.52 1862 470 2.04 / 1259.72 2 2
4 13 960.00 48 12.00 1682 969 3.01 / 1260.69 2 2
5 13 93.64 48 13.98 439 295 3.30 / 1260.98 2 2
6 8 0.12 160 14.21 290 659 3.96 / 1261.64 2 2
Average= 5.03 (KJ/cycle)

Cycle 249 GMT 15/ 2/2023 8:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 23 14.13 429 139 0.14 / 1251.85 2 2
2 12 1096.36 4 11.17 1883 84 0.22 / 1251.93 2 2
3 12 1994.96 115 7.89 3098 2811 3.03 / 1254.74 2 2
4 7 1988.52 24 10.35 3100 770 3.80 / 1255.51 2 2
5 13 1219.56 48 12.36 2028 1203 5.01 / 1256.72 2 2
6 13 105.52 48 14.02 456 307 5.31 / 1257.02 2 2
7 8 0.20 160 14.24 288 656 5.97 / 1257.68 2 2
Average= 5.03 (KJ/cycle)

Cycle 248 GMT 14/ 2/2023 5:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 24 14.12 428 145 0.15 / 1246.88 2 2
2 12 1101.92 115 5.56 1749 1118 1.26 / 1248.00 2 2
3 7 1106.80 24 10.33 1887 468 1.73 / 1248.47 2 2
4 13 1188.28 48 11.31 2000 1086 2.82 / 1249.56 2 2
5 13 1067.44 48 11.77 1826 1032 3.85 / 1250.59 2 2
6 13 265.00 48 13.66 707 464 4.31 / 1251.05 2 2
7 8 0.04 160 14.20 289 657 4.97 / 1251.71 2 2
Average= 5.03 (KJ/cycle)

Cycle 247 GMT 4/ 2/2023 11:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 24 14.11 439 149 0.15 / 1242.11 2 2
2 12 1110.88 115 5.55 1696 1082 1.23 / 1243.19 2 2
3 7 1116.12 24 10.18 1898 464 1.69 / 1243.65 2 2
4 13 1192.76 48 11.01 1995 1054 2.75 / 1244.71 2 2
5 13 1078.72 48 11.55 1836 1018 3.77 / 1245.73 2 2
6 13 168.36 48 13.85 549 365 4.13 / 1246.09 2 2
7 8 0.16 160 14.21 285 648 4.78 / 1246.74 2 2
Average= 5.03 (KJ/cycle)

Cycle 246 GMT 25/ 1/2023 16:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 23 14.13 442 144 0.14 / 1237.91 2 2
2 3 1019.44 1 10.54 1876 20 0.16 / 1237.93 2 2
3 12 1142.00 115 6.74 1881 1458 1.62 / 1239.38 2 2
4 7 1140.00 24 10.50 1932 487 2.11 / 1239.87 2 2
5 13 1007.44 48 11.99 1756 1011 3.12 / 1240.88 2 2
6 13 211.48 48 13.77 633 418 3.54 / 1241.30 2 2
7 8 -0.40 160 14.21 290 659 4.20 / 1241.96 2 2
Average= 5.03 (KJ/cycle)

Cycle 245 GMT 15/ 1/2023 22:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 23 14.11 420 136 0.14 / 1231.87 2 2
2 12 1125.04 4 10.97 1907 84 0.22 / 1231.95 2 2
3 12 1992.84 115 7.89 3095 2808 3.03 / 1234.76 2 2
4 7 1986.04 24 10.35 3112 773 3.80 / 1235.53 2 2
5 13 1217.52 48 12.39 2027 1205 5.01 / 1236.74 2 2
6 13 169.92 48 13.91 556 371 5.38 / 1237.11 2 2
7 8 -0.08 160 14.23 286 651 6.03 / 1237.76 2 2
Average= 5.03 (KJ/cycle)

Cycle 244 GMT 14/ 1/2023 19:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 23 14.10 427 138 0.14 / 1226.97 2 2
2 12 1132.52 115 5.56 1773 1134 1.27 / 1228.11 2 2
3 7 1137.52 24 10.36 1931 480 1.75 / 1228.59 2 2
4 13 1204.08 48 11.46 2004 1102 2.85 / 1229.69 2 2
5 13 1092.68 48 11.87 1855 1057 3.91 / 1230.75 2 2
6 13 145.16 48 13.89 515 343 4.25 / 1231.09 2 2
7 8 0.08 160 14.21 283 643 4.90 / 1231.73 2 2
Average= 5.03 (KJ/cycle)

Cycle 243 GMT 5/ 1/2023 1:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 23 14.11 427 139 0.14 / 1222.18 2 2
2 12 1114.84 115 5.56 1717 1098 1.24 / 1223.27 2 2
3 7 1119.36 24 10.20 1903 466 1.70 / 1223.74 2 2
4 13 1198.24 48 11.07 2002 1064 2.77 / 1224.80 2 2
5 13 1087.08 48 11.61 1846 1029 3.79 / 1225.83 2 2
6 13 167.16 48 13.85 546 363 4.16 / 1226.20 2 2
7 8 -0.20 160 14.21 281 639 4.80 / 1226.83 2 2
Average= 5.03 (KJ/cycle)

Cycle 242 GMT 26/12/2022 6:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 23 14.16 432 141 0.14 / 1218.28 2 2
2 12 1126.24 115 6.96 1847 1478 1.62 / 1219.76 2 2
3 7 1122.88 24 10.56 1907 483 2.10 / 1220.24 2 2
4 13 740.12 48 12.76 1385 848 2.95 / 1221.09 2 2
5 13 111.92 48 13.96 459 308 3.26 / 1221.40 2 2
6 8 0.64 160 14.21 282 641 3.90 / 1222.04 2 2
Average= 5.03 (KJ/cycle)

Cycle 241 GMT 16/12/2022 12:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 23 14.12 430 140 0.14 / 1212.44 2 2
2 12 1092.68 4 10.91 1875 82 0.22 / 1212.52 2 2
3 12 1995.16 115 7.91 3094 2814 3.04 / 1215.33 2 2
4 7 1988.56 24 10.37 3112 775 3.81 / 1216.11 2 2
5 13 1043.20 48 12.66 1787 1086 4.90 / 1217.19 2 2
6 13 105.60 48 14.03 448 302 5.20 / 1217.50 2 2
7 8 0.24 160 14.26 282 643 5.84 / 1218.14 2 2
Average= 5.03 (KJ/cycle)

Cycle 240 GMT 15/12/2022 9:26: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 24 14.10 424 143 0.14 / 1207.52 2 2
2 12 1127.76 115 5.57 1776 1138 1.28 / 1208.66 2 2
3 7 1133.12 24 10.44 1910 479 1.76 / 1209.14 2 2
4 13 1201.64 48 11.53 2012 1114 2.87 / 1210.25 2 2
5 13 1076.76 48 11.98 1839 1057 3.93 / 1211.31 2 2
6 13 152.00 48 13.90 523 349 4.28 / 1211.66 2 2
7 8 0.12 160 14.21 282 641 4.92 / 1212.30 2 2
Average= 5.03 (KJ/cycle)

Cycle 239 GMT 5/12/2022 14:59: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 23 14.11 422 137 0.14 / 1202.70 2 2
2 12 1113.12 115 5.56 1727 1104 1.24 / 1203.81 2 2
3 7 1118.04 24 10.24 1911 470 1.71 / 1204.28 2 2
4 13 1191.92 48 11.24 1998 1078 2.79 / 1205.36 2 2
5 13 1075.88 48 11.78 1844 1043 3.83 / 1206.40 2 2
6 13 143.08 48 13.89 506 337 4.17 / 1206.74 2 2
7 8 0.28 160 14.20 282 641 4.81 / 1207.38 2 2
Average= 5.03 (KJ/cycle)

Cycle 238 GMT 25/11/2022 20:37: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 23 14.15 422 137 0.14 / 1198.72 2 2
2 12 1120.44 115 7.21 1842 1527 1.66 / 1200.25 2 2
3 7 1116.44 24 10.65 1901 486 2.15 / 1200.74 2 2
4 13 849.28 48 12.51 1537 923 3.07 / 1201.66 2 2
5 13 90.32 48 14.00 415 279 3.35 / 1201.94 2 2
6 8 0.32 160 14.21 276 628 3.98 / 1202.57 2 2
Average= 5.03 (KJ/cycle)

Cycle 237 GMT 16/11/2022 2:44: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 23 14.11 424 138 0.14 / 1192.92 2 2
2 12 1096.20 4 10.93 1878 82 0.22 / 1193.00 2 2
3 12 1996.48 115 8.00 3114 2865 3.08 / 1195.86 2 2
4 7 1990.08 24 10.44 3127 784 3.87 / 1196.65 2 2
5 13 902.28 48 12.87 1601 989 4.86 / 1197.64 2 2
6 13 104.56 48 14.01 454 305 5.16 / 1197.94 2 2
7 8 0.16 160 14.23 284 647 5.81 / 1198.59 2 2
Average= 5.04 (KJ/cycle)

Cycle 236 GMT 14/11/2022 23:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 24 14.12 418 142 0.14 / 1187.93 2 2
2 12 1139.84 115 5.57 1799 1152 1.29 / 1189.09 2 2
3 7 1145.04 24 10.49 1948 490 1.78 / 1189.58 2 2
4 13 1227.48 48 11.56 2048 1136 2.92 / 1190.71 2 2
5 13 1109.20 48 12.01 1884 1086 4.01 / 1191.80 2 2
6 13 146.24 48 13.88 511 340 4.35 / 1192.14 2 2
7 8 0.00 160 14.19 281 638 4.99 / 1192.78 2 2
Average= 5.03 (KJ/cycle)

Cycle 235 GMT 5/11/2022 5: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 23 14.10 422 137 0.14 / 1183.09 2 2
2 12 1120.56 115 5.57 1785 1143 1.28 / 1184.23 2 2
3 7 1125.76 24 10.38 1915 477 1.76 / 1184.71 2 2
4 13 1203.24 48 11.39 2012 1100 2.86 / 1185.81 2 2
5 13 961.84 48 12.36 1676 994 3.85 / 1186.80 2 2
6 13 162.72 48 13.85 540 359 4.21 / 1187.16 2 2
7 8 0.60 160 14.19 279 633 4.84 / 1187.79 2 2
Average= 5.03 (KJ/cycle)

Cycle 234 GMT 26/10/2022 10:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 23 14.13 439 143 0.14 / 1179.19 2 2
2 12 1097.00 115 7.49 1820 1568 1.71 / 1180.76 2 2
3 7 1092.40 24 10.72 1863 479 2.19 / 1181.24 2 2
4 13 683.92 48 12.89 1306 808 3.00 / 1182.05 2 2
5 13 79.00 48 14.01 403 271 3.27 / 1182.32 2 2
6 8 0.20 160 14.19 278 631 3.90 / 1182.95 2 2
Average= 5.03 (KJ/cycle)

Cycle 233 GMT 16/10/2022 16:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 23 14.10 428 139 0.14 / 1173.25 2 2
2 12 1108.28 4 10.92 1885 82 0.22 / 1173.34 2 2
3 12 1992.68 115 8.18 3098 2914 3.14 / 1176.25 2 2
4 7 1985.56 24 10.51 3109 784 3.92 / 1177.03 2 2
5 13 1029.76 48 12.71 1778 1085 5.00 / 1178.12 2 2
6 13 84.76 48 14.05 426 287 5.29 / 1178.41 2 2
7 8 -0.16 160 14.25 282 643 5.93 / 1179.05 2 2
Average= 5.04 (KJ/cycle)

Cycle 232 GMT 15/10/2022 13:22:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 24 14.10 434 147 0.15 / 1168.26 2 2
2 12 1118.72 115 5.58 1868 1199 1.35 / 1169.46 2 2
3 7 1123.60 24 10.65 1909 488 1.83 / 1169.95 2 2
4 13 1190.36 48 11.79 2001 1132 2.97 / 1171.08 2 2
5 13 1067.00 48 12.23 1824 1071 4.04 / 1172.15 2 2
6 13 133.84 48 13.92 489 327 4.36 / 1172.48 2 2
7 8 0.04 160 14.20 281 638 5.00 / 1173.11 2 2
Average= 5.03 (KJ/cycle)

Cycle 231 GMT 5/10/2022 19: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 23 14.09 432 140 0.14 / 1163.24 2 2
2 12 1142.60 115 5.58 1838 1179 1.32 / 1164.42 2 2
3 7 1147.80 24 10.49 1940 488 1.81 / 1164.91 2 2
4 13 1215.56 48 11.56 2033 1128 2.94 / 1166.04 2 2
5 13 1098.16 48 12.05 1875 1084 4.02 / 1167.12 2 2
6 13 155.56 48 13.87 526 350 4.37 / 1167.47 2 2
7 8 0.60 160 14.20 282 641 5.01 / 1168.11 2 2
Average= 5.03 (KJ/cycle)

Cycle 230 GMT 26/ 9/2022 0:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 23 14.11 436 141 0.14 / 1159.24 2 2
2 12 1130.00 115 7.51 1860 1606 1.75 / 1160.84 2 2
3 7 1125.92 24 10.78 1912 495 2.24 / 1161.34 2 2
4 13 703.00 48 12.91 1339 830 3.07 / 1162.17 2 2
5 13 95.32 48 13.97 438 294 3.37 / 1162.46 2 2
6 8 0.16 160 14.20 281 638 4.00 / 1163.10 2 2
Average= 5.04 (KJ/cycle)

Cycle 229 GMT 16/ 9/2022 6:42: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 23 14.11 425 138 0.14 / 1153.54 2 2
2 12 1118.72 4 10.98 1905 84 0.22 / 1153.63 2 2
3 12 1993.72 115 8.40 3108 3002 3.22 / 1156.63 2 2
4 7 1987.04 24 10.54 3122 790 4.01 / 1157.42 2 2
5 13 600.40 48 13.26 1199 763 4.78 / 1158.18 2 2
6 13 60.16 48 14.10 380 257 5.03 / 1158.44 2 2
7 8 0.00 160 14.24 289 658 5.69 / 1159.10 2 2
Average= 5.04 (KJ/cycle)

Cycle 228 GMT 15/ 9/2022 3:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 23 14.09 432 140 0.14 / 1148.38 2 2
2 12 1143.12 115 5.61 1931 1246 1.39 / 1149.63 2 2
3 7 1148.84 24 10.70 1959 503 1.89 / 1150.13 2 2
4 13 1228.00 48 11.88 2051 1170 3.06 / 1151.30 2 2
5 13 1111.96 48 12.26 1892 1113 4.17 / 1152.41 2 2
6 13 159.20 48 13.88 530 353 4.52 / 1152.77 2 2
7 8 0.20 160 14.21 281 639 5.16 / 1153.40 2 2
Average= 5.04 (KJ/cycle)

Cycle 227 GMT 5/ 9/2022 9: 9: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 23 14.08 426 138 0.14 / 1143.33 2 2
2 12 1134.40 115 5.59 1871 1203 1.34 / 1144.53 2 2
3 7 1139.96 24 10.55 1936 490 1.83 / 1145.02 2 2
4 13 1221.24 48 11.60 2036 1134 2.96 / 1146.15 2 2
5 13 1103.28 48 12.08 1874 1087 4.05 / 1147.24 2 2
6 13 154.04 48 13.86 532 354 4.41 / 1147.60 2 2
7 8 -0.20 160 14.19 284 645 5.05 / 1148.24 2 2
Average= 5.04 (KJ/cycle)

Cycle 226 GMT 26/ 8/2022 14:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 23 14.11 431 140 0.14 / 1139.37 2 2
2 12 1108.00 115 7.75 1823 1625 1.76 / 1140.99 2 2
3 7 1102.72 24 10.78 1881 487 2.25 / 1141.48 2 2
4 13 680.16 48 12.91 1300 806 3.06 / 1142.28 2 2
5 13 74.80 48 14.02 396 266 3.32 / 1142.55 2 2
6 8 -0.12 160 14.18 282 640 3.96 / 1143.19 2 2
Average= 5.04 (KJ/cycle)

Cycle 225 GMT 16/ 8/2022 20:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 23 14.09 427 138 0.14 / 1133.53 2 2
2 12 1095.40 4 10.97 1876 82 0.22 / 1133.62 2 2
3 12 1987.60 115 8.15 3104 2909 3.13 / 1136.53 2 2
4 7 1979.92 24 10.52 3108 785 3.91 / 1137.31 2 2
5 13 873.16 48 12.88 1578 976 4.89 / 1138.29 2 2
6 13 98.20 48 14.01 439 295 5.19 / 1138.58 2 2
7 8 -0.12 160 14.23 284 647 5.83 / 1139.23 2 2
Average= 5.04 (KJ/cycle)

Cycle 224 GMT 15/ 8/2022 17:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 24 14.08 433 146 0.15 / 1128.50 2 2
2 12 1100.04 115 5.59 1907 1226 1.37 / 1129.72 2 2
3 7 1105.24 24 10.73 1898 489 1.86 / 1130.21 2 2
4 13 1183.80 48 11.84 1996 1134 3.00 / 1131.35 2 2
5 13 1068.64 48 12.25 1840 1082 4.08 / 1132.43 2 2
6 13 124.68 48 13.91 481 321 4.40 / 1132.75 2 2
7 8 -0.24 160 14.19 284 645 5.04 / 1133.40 2 2
Average= 5.04 (KJ/cycle)

Cycle 223 GMT 5/ 8/2022 22:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 24 14.07 436 147 0.15 / 1123.88 2 2
2 12 1103.68 115 6.00 1910 1318 1.47 / 1125.20 2 2
3 7 1107.56 24 10.66 1900 486 1.95 / 1125.68 2 2
4 13 1088.80 48 11.93 1872 1072 3.02 / 1126.75 2 2
5 13 544.20 48 13.16 1124 710 3.73 / 1127.46 2 2
6 13 42.56 48 14.06 350 236 3.97 / 1127.70 2 2
7 8 -0.20 160 14.18 287 651 4.62 / 1128.35 2 2
Average= 5.04 (KJ/cycle)

Cycle 222 GMT 27/ 7/2022 4:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 24 14.10 428 145 0.14 / 1119.84 2 2
2 3 948.44 -1 15.18 0 0 0.00 / 1119.84 2 2
3 3 1036.44 1 11.30 1827 21 0.17 / 1119.86 2 2
4 12 1144.72 115 7.51 1891 1633 1.80 / 1121.49 2 2
5 7 1140.20 24 10.77 1937 501 2.30 / 1121.99 2 2
6 13 724.88 48 12.84 1368 843 3.14 / 1122.84 2 2
7 13 49.00 48 14.04 359 242 3.38 / 1123.08 2 2
8 8 0.32 160 14.15 288 652 4.04 / 1123.73 2 2
Average= 5.04 (KJ/cycle)

Cycle 221 GMT 17/ 7/2022 10:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 23 14.07 433 140 0.14 / 1113.94 2 2
2 12 1099.72 4 10.94 1884 82 0.22 / 1114.03 2 2
3 12 1993.12 115 7.79 3104 2781 3.00 / 1116.81 2 2
4 7 1986.64 24 10.49 3116 784 3.79 / 1117.59 2 2
5 13 1095.60 48 12.57 1880 1134 4.92 / 1118.72 2 2
6 13 119.72 48 13.93 475 318 5.24 / 1119.04 2 2
7 8 0.68 160 14.21 287 653 5.89 / 1119.70 2 2
Average= 5.04 (KJ/cycle)

Cycle 220 GMT 16/ 7/2022 6:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 24 14.07 438 148 0.15 / 1109.76 2 2
2 3 949.40 -1 15.16 0 0 0.00 / 1109.76 2 2
3 3 1028.24 1 11.18 1809 20 0.17 / 1109.78 2 2
4 12 1117.64 115 6.37 1867 1368 1.54 / 1111.14 2 2
5 7 1118.44 24 10.75 1919 495 2.03 / 1111.64 2 2
6 13 1027.84 48 12.25 1779 1046 3.08 / 1112.69 2 2
7 13 264.88 48 13.61 717 468 3.55 / 1113.15 2 2
8 8 -0.08 160 14.17 286 648 4.19 / 1113.80 2 2
Average= 5.04 (KJ/cycle)

Cycle 219 GMT 6/ 7/2022 12:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 23 14.03 440 142 0.14 / 1105.00 2 2
2 12 1155.24 115 5.97 1948 1337 1.48 / 1106.34 2 2
3 7 1160.08 24 10.71 1980 509 1.99 / 1106.84 2 2
4 13 1138.44 48 11.99 1933 1112 3.10 / 1107.96 2 2
5 13 583.12 48 13.15 1181 745 3.85 / 1108.70 2 2
6 13 52.92 48 14.04 369 249 4.09 / 1108.95 2 2
7 8 0.00 160 14.18 290 658 4.75 / 1109.61 2 2
Average= 5.04 (KJ/cycle)

Cycle 218 GMT 26/ 6/2022 18:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 23 14.10 426 138 0.14 / 1101.12 2 2
2 12 1116.00 115 7.90 1833 1665 1.80 / 1102.79 2 2
3 7 1110.88 24 10.89 1891 494 2.30 / 1103.28 2 2
4 13 533.04 48 13.18 1108 701 3.00 / 1103.98 2 2
5 13 39.36 48 14.06 341 230 3.23 / 1104.21 2 2
6 8 -0.12 160 14.17 284 644 3.87 / 1104.86 2 2
Average= 5.05 (KJ/cycle)

Cycle 217 GMT 17/ 6/2022 0:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 24 14.09 427 144 0.14 / 1095.21 2 2
2 12 1093.48 4 11.02 1897 84 0.23 / 1095.29 2 2
3 12 1992.72 115 8.36 3110 2990 3.22 / 1098.28 2 2
4 7 1985.72 24 10.59 3112 791 4.01 / 1099.07 2 2
5 13 876.12 48 12.89 1587 982 4.99 / 1100.06 2 2
6 13 96.84 48 14.02 428 288 5.28 / 1100.34 2 2
7 8 -0.28 160 14.24 281 640 5.92 / 1100.98 2 2
Average= 5.05 (KJ/cycle)

Cycle 216 GMT 15/ 6/2022 21:11: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 23 14.03 442 143 0.14 / 1089.96 2 2
2 10 1021.08 3 12.04 1801 65 0.21 / 1090.03 2 2
3 3 955.84 -1 15.16 0 0 0.07 / 1090.03 2 2
4 12 1154.76 115 5.62 1968 1272 1.48 / 1091.30 2 2
5 7 1159.52 24 10.73 1980 510 1.99 / 1091.81 2 2
6 13 1220.68 48 11.88 2046 1167 3.16 / 1092.98 2 2
7 13 1098.00 48 12.25 1876 1103 4.26 / 1094.08 2 2
8 13 142.16 48 13.87 506 337 4.60 / 1094.42 2 2
9 8 -0.08 160 14.19 286 649 5.25 / 1095.06 2 2
Average= 5.05 (KJ/cycle)

Cycle 215 GMT 6/ 6/2022 2:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 23 14.03 431 139 0.14 / 1085.69 2 2
2 12 1130.32 115 6.23 1913 1371 1.51 / 1087.06 2 2
3 7 1133.16 24 10.72 1931 497 2.01 / 1087.56 2 2
4 13 1067.64 48 12.04 1844 1066 3.07 / 1088.62 2 2
5 13 345.68 48 13.46 835 539 3.61 / 1089.16 2 2
6 8 0.28 160 14.17 290 657 4.27 / 1089.82 2 2
Average= 5.05 (KJ/cycle)

Cycle 214 GMT 27/ 5/2022 8:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 23 14.08 426 138 0.14 / 1081.71 2 2
2 12 1117.44 115 7.78 1841 1647 1.79 / 1083.36 2 2
3 7 1112.56 24 10.86 1893 493 2.28 / 1083.85 2 2
4 13 677.84 48 12.87 1304 806 3.08 / 1084.66 2 2
5 13 37.84 48 14.03 349 235 3.32 / 1084.89 2 2
6 8 0.20 160 14.14 290 656 3.98 / 1085.55 2 2
Average= 5.05 (KJ/cycle)

Cycle 213 GMT 17/ 5/2022 14:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 23 14.03 432 139 0.14 / 1076.10 2 2
2 12 1103.40 4 11.02 1892 83 0.22 / 1076.18 2 2
3 12 1991.28 115 7.66 3104 2734 2.96 / 1078.91 2 2
4 7 1984.64 24 10.48 3125 786 3.74 / 1079.70 2 2
5 13 813.04 48 12.90 1501 929 4.67 / 1080.63 2 2
6 13 94.48 48 13.98 437 293 4.97 / 1080.92 2 2
7 8 -0.16 160 14.20 287 652 5.62 / 1081.57 2 2
Average= 5.05 (KJ/cycle)

Cycle 212 GMT 16/ 5/2022 11: 6: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 23 14.04 431 139 0.14 / 1072.05 2 2
2 12 1094.80 115 6.53 1828 1373 1.51 / 1073.42 2 2
3 7 1094.04 24 10.82 1878 488 2.00 / 1073.91 2 2
4 13 984.44 48 12.25 1725 1014 3.01 / 1074.93 2 2
5 13 182.56 48 13.73 579 382 3.40 / 1075.31 2 2
6 8 0.16 160 14.13 287 649 4.04 / 1075.96 2 2
Average= 5.05 (KJ/cycle)

Cycle 211 GMT 6/ 5/2022 17:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 23 14.03 433 140 0.14 / 1067.88 2 2
2 12 1134.00 115 6.67 1896 1454 1.59 / 1069.33 2 2
3 7 1132.12 24 10.77 1930 499 2.09 / 1069.83 2 2
4 13 1011.00 48 12.22 1755 1029 3.12 / 1070.86 2 2
5 13 199.72 48 13.68 607 399 3.52 / 1071.26 2 2
6 8 0.16 160 14.13 288 651 4.17 / 1071.91 2 2
Average= 5.06 (KJ/cycle)

Cycle 210 GMT 26/ 4/2022 23:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 23 14.08 427 138 0.14 / 1063.97 2 2
2 12 1111.72 115 8.01 1831 1687 1.82 / 1065.65 2 2
3 7 1106.32 24 10.95 1892 497 2.32 / 1066.15 2 2
4 13 538.60 48 13.13 1111 700 3.02 / 1066.85 2 2
5 13 39.60 48 14.03 353 238 3.26 / 1067.09 2 2
6 8 -0.16 160 14.13 289 653 3.91 / 1067.74 2 2
Average= 5.06 (KJ/cycle)

Cycle 209 GMT 17/ 4/2022 5:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 24 14.05 434 146 0.15 / 1058.10 2 2
2 12 1110.60 4 11.11 1899 84 0.23 / 1058.19 2 2
3 12 1984.16 115 8.12 3100 2895 3.13 / 1061.08 2 2
4 7 1976.72 24 10.56 3107 787 3.91 / 1061.87 2 2
5 13 898.92 48 12.82 1619 996 4.91 / 1062.87 2 2
6 13 113.12 48 13.94 466 312 5.22 / 1063.18 2 2
7 8 0.16 160 14.21 285 648 5.87 / 1063.83 2 2
Average= 5.07 (KJ/cycle)

Cycle 208 GMT 16/ 4/2022 1:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 23 14.03 430 139 0.14 / 1053.76 2 2
2 12 1135.16 115 6.15 1935 1369 1.51 / 1055.13 2 2
3 7 1138.60 24 10.84 1955 509 2.02 / 1055.64 2 2
4 13 1087.52 48 12.12 1881 1094 3.11 / 1056.73 2 2
5 13 377.68 48 13.43 881 568 3.68 / 1057.30 2 2
6 8 0.08 160 14.17 291 660 4.34 / 1057.96 2 2
Average= 5.06 (KJ/cycle)

Cycle 207 GMT 6/ 4/2022 7:20: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 23 14.04 434 140 0.14 / 1049.74 2 2
2 12 1094.64 115 7.10 1810 1478 1.62 / 1051.22 2 2
3 7 1091.20 24 10.85 1868 486 2.10 / 1051.70 2 2
4 13 960.52 48 12.27 1693 997 3.10 / 1052.70 2 2
5 13 68.92 48 13.95 393 263 3.36 / 1052.96 2 2
6 8 1.12 160 14.12 291 657 4.02 / 1053.62 2 2
Average= 5.07 (KJ/cycle)

Cycle 206 GMT 27/ 3/2022 13:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 24 14.10 434 147 0.15 / 1045.61 2 2
2 3 961.60 -1 15.21 0 0 0.00 / 1045.61 2 2
3 3 1041.32 1 11.64 1829 21 0.17 / 1045.63 2 2
4 12 1146.88 115 7.85 1906 1721 1.89 / 1047.36 2 2
5 7 1142.20 24 10.90 1941 508 2.40 / 1047.86 2 2
6 13 715.72 48 12.83 1365 841 3.24 / 1048.70 2 2
7 13 39.96 48 14.05 349 235 3.47 / 1048.94 2 2
8 8 0.40 160 14.15 291 659 4.13 / 1049.60 2 2
Average= 5.07 (KJ/cycle)

Cycle 205 GMT 17/ 3/2022 19:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 23 14.03 445 144 0.14 / 1039.70 2 2
2 3 1021.80 1 10.74 1874 20 0.16 / 1039.72 2 2
3 12 1116.64 4 11.05 1907 84 0.25 / 1039.81 2 2
4 12 1981.44 115 7.83 3085 2778 3.03 / 1042.59 2 2
5 7 1973.80 24 10.53 3106 785 3.81 / 1043.37 2 2
6 13 1034.72 48 12.61 1797 1088 4.90 / 1044.46 2 2
7 13 155.96 48 13.86 533 355 5.25 / 1044.81 2 2
8 8 0.56 160 14.21 287 653 5.91 / 1045.47 2 2
Average= 5.08 (KJ/cycle)

Cycle 204 GMT 16/ 3/2022 16:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 23 14.03 433 140 0.14 / 1035.55 2 2
2 12 1116.12 115 6.83 1840 1445 1.58 / 1037.00 2 2
3 7 1113.96 24 10.89 1906 498 2.08 / 1037.50 2 2
4 13 995.56 48 12.28 1739 1025 3.11 / 1038.52 2 2
5 13 186.68 48 13.73 584 385 3.49 / 1038.91 2 2
6 8 0.08 160 14.16 289 655 4.15 / 1039.56 2 2
Average= 5.07 (KJ/cycle)

Cycle 203 GMT 6/ 3/2022 22:19: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 23 14.02 432 139 0.14 / 1031.38 2 2
2 3 1019.48 1 11.11 1873 21 0.16 / 1031.40 2 2
3 12 1132.92 115 7.02 1883 1520 1.68 / 1032.92 2 2
4 7 1130.04 24 10.86 1943 506 2.19 / 1033.42 2 2
5 13 1000.08 48 12.25 1750 1029 3.22 / 1034.45 2 2
6 13 99.40 48 13.88 452 301 3.52 / 1034.75 2 2
7 8 0.16 160 14.14 292 661 4.18 / 1035.41 2 2
Average= 5.08 (KJ/cycle)

Cycle 202 GMT 25/ 2/2022 4:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 23 14.07 431 139 0.14 / 1027.70 2 2
2 12 1097.96 115 8.20 1835 1730 1.87 / 1029.43 2 2
3 7 1091.92 24 10.97 1870 492 2.36 / 1029.92 2 2
4 13 504.32 48 13.17 1060 670 3.03 / 1030.59 2 2
5 8 0.20 160 14.14 285 645 3.68 / 1031.24 2 2
Average= 5.08 (KJ/cycle)

Cycle 201 GMT 15/ 2/2022 10:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 23 14.03 429 138 0.14 / 1021.92 2 2
2 12 1103.60 4 11.17 1896 85 0.22 / 1022.00 2 2
3 12 1990.68 115 7.80 3097 2778 3.00 / 1024.78 2 2
4 7 1983.84 24 10.53 3124 789 3.79 / 1025.57 2 2
5 13 918.96 48 12.76 1634 1001 4.79 / 1026.57 2 2
6 13 125.44 48 13.90 493 329 5.12 / 1026.90 2 2
7 8 0.52 160 14.19 291 661 5.78 / 1027.56 2 2
Average= 5.09 (KJ/cycle)

Cycle 200 GMT 14/ 2/2022 6:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 23 14.03 430 139 0.14 / 1017.92 2 2
2 12 1122.96 115 7.02 1847 1491 1.63 / 1019.41 2 2
3 7 1119.84 24 10.90 1910 500 2.13 / 1019.91 2 2
4 13 847.64 48 12.56 1543 930 3.06 / 1020.84 2 2
5 13 89.28 48 13.92 429 287 3.35 / 1021.12 2 2
6 8 0.36 160 14.14 289 654 4.00 / 1021.78 2 2
Average= 5.08 (KJ/cycle)

Cycle 199 GMT 4/ 2/2022 12:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 23 14.05 425 137 0.14 / 1013.92 2 2
2 12 1123.24 115 7.27 1863 1558 1.69 / 1015.48 2 2
3 7 1120.00 24 10.94 1911 502 2.20 / 1015.98 2 2
4 13 732.84 48 12.76 1384 848 3.04 / 1016.82 2 2
5 13 95.48 48 13.89 439 293 3.34 / 1017.12 2 2
6 8 -0.36 160 14.13 292 660 4.00 / 1017.78 2 2
Average= 5.09 (KJ/cycle)

Cycle 198 GMT 25/ 1/2022 18:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 23 14.10 431 140 0.14 / 1010.21 2 2
2 12 1110.00 115 8.32 1841 1761 1.90 / 1011.97 2 2
3 7 1104.00 24 11.06 1888 501 2.40 / 1012.47 2 2
4 13 500.48 48 13.19 1054 667 3.07 / 1013.14 2 2
5 8 0.20 160 14.17 282 639 3.71 / 1013.78 2 2
Average= 5.09 (KJ/cycle)

Cycle 197 GMT 16/ 1/2022 1: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 24 14.08 426 144 0.14 / 1004.38 2 2
2 3 936.20 -1 15.21 0 0 0.00 / 1004.38 2 2
3 12 1106.80 4 11.40 1909 87 0.23 / 1004.47 2 2
4 12 1978.88 115 8.17 3076 2890 3.12 / 1007.36 2 2
5 7 1971.16 24 10.62 3087 787 3.91 / 1008.15 2 2
6 13 867.16 48 12.85 1579 974 4.88 / 1009.12 2 2
7 13 102.52 48 13.99 447 300 5.18 / 1009.42 2 2
8 8 0.12 160 14.24 286 652 5.83 / 1010.07 2 2
Average= 5.10 (KJ/cycle)

Cycle 196 GMT 14/ 1/2022 21:11: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 23 14.09 431 140 0.14 / 1000.20 2 2
2 12 1098.20 115 7.42 1834 1565 1.70 / 1001.76 2 2
3 7 1094.16 24 11.04 1890 501 2.21 / 1002.26 2 2
4 13 969.04 48 12.33 1718 1017 3.22 / 1003.28 2 2
5 13 115.92 48 13.88 464 309 3.53 / 1003.59 2 2
6 8 0.00 160 14.16 286 648 4.18 / 1004.24 2 2
Average= 5.10 (KJ/cycle)

Cycle 195 GMT 5/ 1/2022 3:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 23 14.04 442 143 0.14 / 996.07 2 2
2 12 1122.48 115 7.54 1855 1608 1.75 / 997.68 2 2
3 7 1118.60 24 11.10 1909 509 2.26 / 998.19 2 2
4 13 844.52 48 12.69 1540 938 3.20 / 999.13 2 2
5 13 69.52 48 14.01 397 267 3.46 / 999.39 2 2
6 8 -0.20 160 14.17 293 664 4.13 / 1000.06 2 2
Average= 5.10 (KJ/cycle)

Cycle 194 GMT 26/12/2021 9:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 23 14.11 431 140 0.14 / 992.08 2 2
2 12 1126.28 80 8.60 1876 1291 1.43 / 993.37 2 2
3 7 1123.80 24 11.20 1916 515 1.95 / 993.89 2 2
4 13 991.64 48 12.36 1722 1022 2.97 / 994.91 2 2
5 13 157.88 48 13.78 545 360 3.33 / 995.27 2 2
6 8 0.00 160 14.16 291 659 3.99 / 995.93 2 2
Average= 5.11 (KJ/cycle)

Cycle 193 GMT 16/12/2021 16: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 23 14.05 447 144 0.14 / 986.65 2 2
2 3 1035.60 1 11.70 1828 21 0.17 / 986.67 2 2
3 12 1103.28 4 11.43 1922 88 0.25 / 986.76 2 2
4 12 1992.12 80 8.62 3107 2143 2.40 / 988.90 2 2
5 7 1986.36 24 10.50 3133 790 3.19 / 989.69 2 2
6 13 1256.64 48 12.30 2093 1236 4.42 / 990.93 2 2
7 13 148.68 48 13.89 532 355 4.78 / 991.28 2 2
8 8 0.24 160 14.23 290 660 5.44 / 991.94 2 2
Average= 5.11 (KJ/cycle)

Cycle 192 GMT 15/12/2021 11:58: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 23 14.05 440 142 0.14 / 982.74 2 2
2 12 1137.84 80 7.17 1898 1089 1.23 / 983.83 2 2
3 7 1138.12 25 11.04 1943 536 1.77 / 984.36 2 2
4 13 1019.12 48 12.19 1779 1041 2.81 / 985.40 2 2
5 13 236.20 48 13.62 672 439 3.25 / 985.84 2 2
6 8 0.12 160 14.17 292 662 3.91 / 986.51 2 2
Average= 5.11 (KJ/cycle)

Cycle 191 GMT 5/12/2021 18: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 23 14.07 437 141 0.14 / 978.89 2 2
2 12 1115.04 80 7.83 1856 1163 1.30 / 980.06 2 2
3 7 1112.88 24 11.12 1909 509 1.81 / 980.56 2 2
4 13 984.00 48 12.25 1712 1007 2.82 / 981.57 2 2
5 13 166.16 48 13.73 562 370 3.19 / 981.94 2 2
6 8 0.20 160 14.16 289 655 3.85 / 982.60 2 2
Average= 5.12 (KJ/cycle)

Cycle 190 GMT 26/11/2021 0:10: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 23 14.16 436 142 0.14 / 975.12 2 2
2 12 1122.60 80 8.95 1875 1342 1.48 / 976.46 2 2
3 7 1119.12 24 11.20 1921 516 2.00 / 976.98 2 2
4 13 726.68 48 12.81 1378 847 2.85 / 977.83 2 2
5 13 52.36 48 14.03 376 253 3.10 / 978.08 2 2
6 8 -0.40 160 14.17 296 671 3.77 / 978.75 2 2
Average= 5.12 (KJ/cycle)

Cycle 189 GMT 16/11/2021 6:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 22 14.15 433 135 0.13 / 969.48 2 2
2 3 1040.68 1 11.60 1816 21 0.16 / 969.50 2 2
3 3 1022.92 1 11.04 1791 20 0.18 / 969.52 2 2
4 12 1111.12 5 11.52 1944 112 0.29 / 969.63 2 2
5 12 1950.92 80 9.62 3058 2353 2.64 / 971.99 2 2
6 7 1943.92 24 10.76 3050 788 3.43 / 972.77 2 2
7 13 1164.04 48 12.63 1977 1199 4.63 / 973.97 2 2
8 13 127.48 48 13.95 505 338 4.97 / 974.31 2 2
9 8 0.32 160 14.27 293 669 5.63 / 974.98 2 2
Average= 5.13 (KJ/cycle)

Cycle 188 GMT 15/11/2021 2:28: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 23 14.16 433 141 0.14 / 960.17 2 2
2 12 1103.44 14 8.82 1828 226 0.37 / 960.39 2 2
3 12 1959.80 200 5.91 3180 3759 4.13 / 964.15 2 2
4 12 1957.28 80 7.86 3098 1948 6.07 / 966.10 2 2
5 7 1951.92 24 10.76 3102 801 6.87 / 966.90 2 2
6 13 1393.24 48 12.28 2287 1348 8.22 / 968.25 2 2
7 13 245.48 48 13.72 680 448 8.67 / 968.70 2 2
8 8 0.04 160 14.28 284 649 9.32 / 969.34 2 2
Average= 5.13 (KJ/cycle)

Cycle 187 GMT 5/11/2021 1:23:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 23 14.21 430 141 0.14 / 950.84 2 2
2 12 1127.12 14 8.51 1885 225 0.37 / 951.06 2 2
3 12 1965.92 200 5.97 3180 3797 4.16 / 954.86 2 2
4 12 1957.68 80 8.04 3066 1972 6.13 / 956.83 2 2
5 7 1950.76 24 10.81 3073 797 6.93 / 957.63 2 2
6 13 1479.64 48 12.25 2374 1396 8.33 / 959.02 2 2
7 13 159.00 48 13.90 537 358 8.69 / 959.38 2 2
8 8 0.08 160 14.30 281 643 9.33 / 960.02 2 2
Average= 5.11 (KJ/cycle)

Cycle 186 GMT 26/10/2021 0:30:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 23 14.20 429 140 0.14 / 941.38 2 2
2 12 1112.92 14 8.20 1846 212 0.35 / 941.59 2 2
3 12 1990.28 200 5.85 3069 3591 3.94 / 945.19 2 2
4 12 1990.40 80 7.40 3163 1872 5.82 / 947.06 2 2
5 7 1985.44 24 10.86 3130 816 6.63 / 947.87 2 2
6 13 1712.76 48 11.99 2684 1545 8.18 / 949.42 2 2
7 13 461.80 48 13.46 994 642 8.82 / 950.06 2 2
8 8 0.12 160 14.34 277 636 9.45 / 950.70 2 2
Average= 5.08 (KJ/cycle)

Cycle 185 GMT 15/10/2021 23:22: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 23 14.22 427 140 0.14 / 932.01 2 2
2 12 1127.44 14 8.48 1887 224 0.36 / 932.23 2 2
3 12 1983.20 200 6.09 3197 3894 4.26 / 936.13 2 2
4 12 1973.80 80 8.35 3121 2085 6.34 / 938.21 2 2
5 7 1966.36 24 10.98 3109 819 7.16 / 939.03 2 2
6 13 1173.48 48 12.60 1988 1202 8.36 / 940.23 2 2
7 13 164.00 48 13.90 543 362 8.73 / 940.60 2 2
8 8 0.04 160 14.30 283 648 9.37 / 941.24 2 2
Average= 5.06 (KJ/cycle)

Cycle 184 GMT 5/10/2021 22:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 23 14.21 427 140 0.14 / 922.72 2 2
2 12 1113.04 14 8.54 1846 221 0.36 / 922.94 2 2
3 12 1985.40 200 5.87 3165 3716 4.08 / 926.65 2 2
4 12 1984.12 80 7.62 3118 1901 5.98 / 928.55 2 2
5 7 1979.40 24 10.97 3121 822 6.80 / 929.38 2 2
6 13 1419.64 48 12.40 2307 1373 8.17 / 930.75 2 2
7 13 281.20 48 13.70 731 481 8.65 / 931.23 2 2
8 8 0.16 160 14.31 279 639 9.29 / 931.87 2 2
Average= 5.04 (KJ/cycle)

Cycle 183 GMT 25/ 9/2021 21:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 23 14.22 430 141 0.14 / 914.27 2 2
2 12 1103.72 14 9.20 1848 238 0.38 / 914.51 2 2
3 12 1946.40 120 5.92 3216 2285 2.66 / 916.80 2 2
4 12 1944.92 80 7.01 3134 1758 4.42 / 918.55 2 2
5 7 1940.84 24 10.89 3066 801 5.22 / 919.36 2 2
6 13 1808.52 48 11.82 2861 1623 6.85 / 920.98 2 2
7 13 509.00 48 13.42 1069 689 7.53 / 921.67 2 2
8 13 71.08 48 14.13 391 265 7.80 / 921.93 2 2
9 8 0.32 160 14.31 282 646 8.44 / 922.58 2 2
Average= 5.01 (KJ/cycle)

Cycle 182 GMT 15/ 9/2021 20:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 23 14.21 433 142 0.14 / 905.30 2 2
2 12 1115.20 14 8.27 1856 215 0.36 / 905.51 2 2
3 12 2004.60 120 5.85 2948 2069 2.43 / 907.58 2 2
4 12 2005.68 80 5.87 3355 1576 4.00 / 909.16 2 2
5 7 2005.92 24 10.86 3172 827 4.83 / 909.98 2 2
6 13 1920.20 48 11.66 3017 1689 6.52 / 911.67 2 2
7 13 1490.92 48 12.37 2401 1426 7.94 / 913.10 2 2
8 13 193.28 48 13.88 589 392 8.33 / 913.49 2 2
9 8 -0.16 160 14.33 281 644 8.98 / 914.13 2 2
Average= 5.00 (KJ/cycle)

Cycle 181 GMT 5/ 9/2021 19:22: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 23 14.26 428 140 0.14 / 897.58 2 2
2 12 1116.52 14 9.23 1862 241 0.38 / 897.82 2 2
3 12 1958.36 120 6.04 3228 2340 2.72 / 900.16 2 2
4 12 1950.60 80 7.67 3045 1868 4.59 / 902.03 2 2
5 7 1944.16 24 10.95 3069 807 5.40 / 902.84 2 2
6 13 1222.24 48 12.58 2046 1235 6.63 / 904.07 2 2
7 13 226.52 48 13.78 649 429 7.06 / 904.50 2 2
8 8 -0.08 160 14.28 286 653 7.71 / 905.15 2 2
Average= 4.97 (KJ/cycle)

Cycle 180 GMT 26/ 8/2021 18:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 23 14.22 428 140 0.14 / 888.73 2 2
2 12 1115.16 15 8.48 1857 236 0.38 / 888.96 2 2
3 12 2002.00 120 5.83 2935 2053 2.43 / 891.02 2 2
4 12 2006.92 80 5.85 3323 1555 3.98 / 892.57 2 2
5 7 2008.04 24 10.93 3175 833 4.82 / 893.41 2 2
6 13 1924.76 48 11.68 3015 1690 6.51 / 895.10 2 2
7 13 1332.20 48 12.56 2180 1314 7.82 / 896.41 2 2
8 13 190.52 48 13.89 588 392 8.21 / 896.80 2 2
9 8 -0.04 160 14.33 278 637 8.85 / 897.44 2 2
Average= 4.96 (KJ/cycle)

Cycle 179 GMT 16/ 8/2021 17:51: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 24 14.25 420 144 0.14 / 881.49 2 2
2 12 1102.20 15 9.15 1861 255 0.40 / 881.75 2 2
3 12 1940.48 120 6.83 3045 2496 2.89 / 884.25 2 2
4 12 1924.16 80 7.33 3008 1764 4.66 / 886.01 2 2
5 7 1915.84 24 11.04 3025 802 5.46 / 886.81 2 2
6 13 724.24 48 13.11 1395 878 6.34 / 887.69 2 2
7 13 40.64 48 14.17 350 238 6.58 / 887.93 2 2
8 8 -0.20 160 14.27 290 662 7.24 / 888.59 2 2
Average= 4.94 (KJ/cycle)

Cycle 178 GMT 6/ 8/2021 17:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 24 14.23 432 148 0.15 / 872.79 2 2
2 12 1073.72 15 8.32 1795 224 0.37 / 873.02 2 2
3 12 2002.20 120 5.82 2855 1994 2.37 / 875.01 2 2
4 12 2005.72 80 5.84 3260 1523 3.89 / 876.53 2 2
5 7 2006.52 24 11.05 3174 842 4.73 / 877.38 2 2
6 13 1919.92 48 11.80 3010 1705 6.44 / 879.08 2 2
7 13 1186.32 48 12.77 1985 1217 7.65 / 880.30 2 2
8 13 199.12 48 13.87 605 403 8.05 / 880.70 2 2
9 8 0.00 160 14.30 284 650 8.70 / 881.35 2 2
Average= 4.92 (KJ/cycle)

Cycle 177 GMT 27/ 7/2021 17: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 23 14.26 436 143 0.14 / 866.42 2 2
2 3 1036.32 1 12.12 1813 22 0.16 / 866.44 2 2
3 3 1022.60 1 11.41 1813 21 0.19 / 866.47 2 2
4 12 1118.40 15 9.22 1861 257 0.44 / 866.72 2 2
5 12 1954.76 112 6.95 3026 2355 2.80 / 869.08 2 2
6 12 1946.56 33 7.23 3034 724 3.52 / 869.80 2 2
7 7 1940.28 24 11.05 3056 810 4.33 / 870.61 2 2
8 13 1026.32 48 12.83 1783 1098 5.43 / 871.71 2 2
9 13 87.16 48 14.08 424 287 5.72 / 872.00 2 2
10 8 -0.04 160 14.29 284 649 6.37 / 872.65 2 2
Average= 4.90 (KJ/cycle)

Cycle 176 GMT 17/ 7/2021 16: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 23 14.25 425 139 0.14 / 858.75 2 2
2 12 1092.80 15 8.55 1809 232 0.37 / 858.98 2 2
3 12 2001.88 112 5.84 2894 1893 2.26 / 860.87 2 2
4 12 2003.24 33 5.86 3268 632 2.90 / 861.50 2 2
5 7 2003.72 24 11.03 3165 838 3.73 / 862.34 2 2
6 13 1914.68 48 11.83 3004 1706 5.44 / 864.05 2 2
7 13 1173.56 48 12.78 1977 1213 6.65 / 865.26 2 2
8 13 174.52 48 13.94 559 374 7.03 / 865.63 2 2
9 8 0.56 160 14.29 283 647 7.67 / 866.28 2 2
Average= 4.89 (KJ/cycle)

Cycle 175 GMT 7/ 7/2021 15:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 23 14.29 424 139 0.14 / 852.12 2 2
2 3 1024.84 1 12.05 1833 22 0.16 / 852.14 2 2
3 12 1119.36 13 8.81 1855 212 0.37 / 852.35 2 2
4 12 1977.88 115 7.16 3121 2570 2.94 / 854.92 2 2
5 7 1971.16 24 11.16 3106 832 3.78 / 855.75 2 2
6 13 1558.64 48 12.30 2494 1472 5.25 / 857.23 2 2
7 13 309.20 48 13.69 776 510 5.76 / 857.74 2 2
8 13 25.64 48 14.23 322 220 5.98 / 857.96 2 2
9 8 -0.04 160 14.29 284 649 6.63 / 858.61 2 2
Average= 4.88 (KJ/cycle)

Cycle 174 GMT 27/ 6/2021 14: 4: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 22 14.25 434 136 0.14 / 844.35 2 2
2 12 1147.84 13 8.89 1908 221 0.36 / 844.57 2 2
3 12 2006.92 115 5.97 3362 2308 2.66 / 846.87 2 2
4 7 2008.56 24 11.30 3180 862 3.53 / 847.74 2 2
5 13 1917.12 48 11.96 3018 1733 5.26 / 849.47 2 2
6 13 1451.32 48 12.54 2339 1408 6.67 / 850.88 2 2
7 13 244.16 48 13.83 674 447 7.12 / 851.32 2 2
8 8 0.72 160 14.30 286 654 7.77 / 851.98 2 2
Average= 4.87 (KJ/cycle)

Cycle 173 GMT 17/ 6/2021 14:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 22 14.29 427 134 0.13 / 837.55 2 2
2 12 1102.60 13 8.78 1836 210 0.34 / 837.76 2 2
3 12 2005.68 85 5.93 3135 1580 1.92 / 839.34 2 2
4 7 2006.80 24 11.14 3158 844 2.77 / 840.18 2 2
5 13 1918.76 48 11.86 3005 1711 4.48 / 841.89 2 2
6 13 1201.72 48 12.73 2026 1238 5.72 / 843.13 2 2
7 13 219.84 48 13.83 642 426 6.14 / 843.56 2 2
8 8 0.44 160 14.28 286 653 6.80 / 844.21 2 2
Average= 4.85 (KJ/cycle)

Cycle 172 GMT 7/ 6/2021 14:33:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 22 14.29 422 133 0.13 / 830.77 2 2
2 12 1108.12 13 9.29 1857 224 0.36 / 831.00 2 2
3 12 2002.80 85 6.37 3248 1759 2.12 / 832.76 2 2
4 7 2000.52 24 11.21 3164 851 2.97 / 833.61 2 2
5 13 1892.08 48 11.93 2967 1699 4.67 / 835.31 2 2
6 13 1131.40 48 12.81 1921 1181 5.85 / 836.49 2 2
7 13 74.68 48 14.13 403 273 6.12 / 836.76 2 2
8 8 0.04 160 14.30 284 650 6.77 / 837.41 2 2
Average= 4.84 (KJ/cycle)

Cycle 171 GMT 28/ 5/2021 14:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 23 14.29 422 139 0.14 / 824.08 2 2
2 12 1112.40 13 8.38 1864 203 0.34 / 824.28 2 2
3 12 2005.32 85 5.95 3275 1656 2.00 / 825.94 2 2
4 7 2007.36 24 11.21 3140 845 2.84 / 826.78 2 2
5 13 1935.16 48 11.91 3036 1736 4.58 / 828.52 2 2
6 13 1073.56 48 12.90 1827 1131 5.71 / 829.65 2 2
7 13 134.76 48 14.01 505 340 6.05 / 829.99 2 2
8 8 0.44 160 14.29 286 654 6.70 / 830.64 2 2
Average= 4.83 (KJ/cycle)

Cycle 170 GMT 18/ 5/2021 14:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 22 14.28 428 134 0.13 / 817.48 2 2
2 12 1118.24 11 7.38 1950 158 0.29 / 817.64 2 2
3 12 2002.76 74 6.47 3258 1560 1.85 / 819.20 2 2
4 7 2001.08 24 11.23 3175 856 2.71 / 820.05 2 2
5 13 1894.36 48 11.93 2994 1714 4.42 / 821.77 2 2
6 13 1145.56 48 12.81 1921 1181 5.60 / 822.95 2 2
7 13 141.00 48 14.01 511 344 5.95 / 823.29 2 2
8 8 0.20 160 14.30 283 648 6.60 / 823.94 2 2
Average= 4.82 (KJ/cycle)

Cycle 169 GMT 8/ 5/2021 15: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 22 14.28 436 137 0.14 / 811.01 2 2
2 12 1126.96 11 5.82 2228 143 0.28 / 811.15 2 2
3 12 2009.00 74 6.07 3334 1498 1.78 / 812.65 2 2
4 7 2010.16 24 11.26 3180 859 2.64 / 813.51 2 2
5 13 1919.80 48 11.94 3013 1727 4.36 / 815.24 2 2
6 13 975.68 48 12.98 1709 1065 5.43 / 816.30 2 2
7 13 187.24 48 13.92 592 396 5.82 / 816.70 2 2
8 8 -0.36 160 14.30 283 648 6.47 / 817.34 2 2
Average= 4.81 (KJ/cycle)

Cycle 168 GMT 28/ 4/2021 14:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 22 14.28 429 135 0.13 / 804.84 2 2
2 12 1122.68 11 5.83 2291 147 0.28 / 804.99 2 2
3 12 2001.68 74 7.08 3194 1673 1.96 / 806.66 2 2
4 7 1997.00 24 11.17 3132 840 2.79 / 807.50 2 2
5 13 1736.12 48 12.13 2749 1601 4.40 / 809.10 2 2
6 13 673.44 48 13.26 1310 834 5.23 / 809.94 2 2
7 13 75.32 48 14.15 413 281 5.51 / 810.22 2 2
8 8 0.32 160 14.29 287 656 6.17 / 810.87 2 2
Average= 4.80 (KJ/cycle)

Cycle 167 GMT 18/ 4/2021 15:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 22 14.31 430 135 0.14 / 798.75 2 2
2 12 1136.52 10 8.32 1902 158 0.29 / 798.91 2 2
3 12 2007.64 63 7.40 3113 1451 1.74 / 800.36 2 2
4 7 2004.08 24 11.16 3153 844 2.59 / 801.20 2 2
5 13 1890.80 48 11.87 2968 1691 4.28 / 802.90 2 2
6 13 772.52 48 13.16 1437 908 5.19 / 803.80 2 2
7 13 60.20 48 14.19 380 259 5.45 / 804.06 2 2
8 8 -0.04 160 14.30 282 645 6.09 / 804.71 2 2
Average= 4.79 (KJ/cycle)

Cycle 166 GMT 8/ 4/2021 15:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 22 14.29 425 134 0.13 / 792.71 2 2
2 12 1104.00 10 8.85 1839 163 0.30 / 792.87 2 2
3 12 2002.08 63 7.33 3085 1425 1.72 / 794.30 2 2
4 7 1997.60 24 11.14 3133 838 2.56 / 795.14 2 2
5 13 1873.92 48 11.89 2951 1684 4.24 / 796.82 2 2
6 13 799.16 48 13.12 1474 928 5.17 / 797.75 2 2
7 13 29.36 48 14.25 324 222 5.39 / 797.97 2 2
8 8 -0.08 160 14.29 282 645 6.04 / 798.61 2 2
Average= 4.78 (KJ/cycle)

Cycle 165 GMT 29/ 3/2021 15:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 23 14.32 415 137 0.14 / 786.77 2 2
2 3 955.12 -1 15.23 0 0 0.00 / 786.77 2 2
3 3 1030.04 1 12.42 1838 23 0.16 / 786.80 2 2
4 12 1130.36 10 9.20 1882 173 0.33 / 786.97 2 2
5 12 2020.44 63 7.91 3083 1536 1.87 / 788.51 2 2
6 7 2016.16 24 11.12 3167 845 2.71 / 789.35 2 2
7 13 1900.64 48 11.87 2975 1695 4.41 / 791.05 2 2
8 13 492.64 48 13.46 1041 673 5.08 / 791.72 2 2
9 13 13.16 48 14.27 301 206 5.29 / 791.93 2 2
10 8 -0.12 160 14.24 286 652 5.94 / 792.58 2 2
Average= 4.77 (KJ/cycle)

Cycle 164 GMT 19/ 3/2021 15:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 23 14.31 427 141 0.14 / 780.73 2 2
2 12 1095.00 9 8.32 1927 144 0.28 / 780.88 2 2
3 12 2007.00 60 7.67 3127 1439 1.72 / 782.32 2 2
4 7 2003.24 24 11.13 3122 834 2.56 / 783.15 2 2
5 13 1883.32 48 11.85 2953 1680 4.24 / 784.83 2 2
6 13 786.40 48 13.12 1459 919 5.16 / 785.75 2 2
7 13 51.20 48 14.20 360 245 5.40 / 786.00 2 2
8 8 -0.72 160 14.28 281 642 6.04 / 786.64 2 2
Average= 4.77 (KJ/cycle)

Cycle 163 GMT 9/ 3/2021 15:50: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 23 14.32 415 137 0.14 / 775.11 2 2
2 3 961.44 -1 15.22 0 0 0.00 / 775.11 2 2
3 3 1044.88 1 12.59 1837 23 0.16 / 775.13 2 2
4 12 1131.80 9 9.42 1886 160 0.32 / 775.29 2 2
5 12 2001.44 60 8.23 3097 1529 1.85 / 776.82 2 2
6 7 1996.28 24 11.17 3143 843 2.69 / 777.67 2 2
7 13 1731.12 48 12.09 2738 1589 4.28 / 779.25 2 2
8 13 506.52 48 13.44 1065 687 4.97 / 779.94 2 2
9 8 -0.20 160 14.26 286 653 5.62 / 780.59 2 2
Average= 4.76 (KJ/cycle)

Cycle 162 GMT 27/ 2/2021 16:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 22 14.30 440 138 0.14 / 769.52 2 2
2 3 1021.04 1 12.19 1868 23 0.16 / 769.54 2 2
3 12 1129.48 8 8.26 1921 127 0.29 / 769.67 2 2
4 12 2005.12 56 8.41 3106 1463 1.75 / 771.13 2 2
5 7 2000.00 24 11.24 3136 846 2.60 / 771.98 2 2
6 13 1734.60 48 12.09 2745 1593 4.19 / 773.57 2 2
7 13 613.00 48 13.31 1214 776 4.97 / 774.34 2 2
8 8 -0.08 160 14.29 275 629 5.59 / 774.97 2 2
Average= 4.75 (KJ/cycle)

Cycle 161 GMT 17/ 2/2021 16:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 23 14.29 428 141 0.14 / 763.94 2 2
2 12 1088.36 8 9.18 1818 134 0.27 / 764.08 2 2
3 12 2004.68 56 8.15 3057 1395 1.67 / 765.47 2 2
4 7 2000.20 24 11.20 3145 845 2.51 / 766.32 2 2
5 13 1868.60 48 11.82 2956 1677 4.19 / 767.99 2 2
6 13 568.28 48 13.36 1156 741 4.93 / 768.74 2 2
7 8 0.48 160 14.28 282 644 5.58 / 769.38 2 2
Average= 4.75 (KJ/cycle)

Cycle 160 GMT 7/ 2/2021 17:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 23 14.31 427 141 0.14 / 758.31 2 2
2 12 1100.76 7 8.82 1850 114 0.25 / 758.43 2 2
3 12 2003.56 54 8.41 3087 1402 1.66 / 759.83 2 2
4 7 1999.60 24 11.07 3121 829 2.49 / 760.66 2 2
5 13 1731.88 48 12.04 2747 1588 4.07 / 762.25 2 2
6 13 510.28 48 13.43 1070 690 4.76 / 762.94 2 2
7 13 38.68 48 14.24 333 228 4.99 / 763.16 2 2
8 8 -0.04 160 14.27 279 637 5.63 / 763.80 2 2
Average= 4.74 (KJ/cycle)

Cycle 159 GMT 28/ 1/2021 17:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 23 14.30 441 145 0.15 / 752.63 2 2
2 3 941.84 -1 15.22 0 0 0.00 / 752.63 2 2
3 3 1027.56 1 12.25 1820 22 0.17 / 752.65 2 2
4 12 1116.80 7 7.38 2170 112 0.28 / 752.76 2 2
5 12 2002.64 54 8.83 3086 1471 1.75 / 754.24 2 2
6 7 1998.76 24 11.13 3129 836 2.59 / 755.07 2 2
7 13 1605.64 48 12.22 2551 1496 4.08 / 756.57 2 2
8 13 550.88 48 13.39 1129 726 4.81 / 757.29 2 2
9 13 35.44 48 14.23 340 232 5.04 / 757.53 2 2
10 8 0.04 160 14.26 284 648 5.69 / 758.17 2 2
Average= 4.74 (KJ/cycle)

Cycle 158 GMT 18/ 1/2021 17:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 23 14.31 433 143 0.14 / 746.55 2 2
2 12 1098.24 6 8.01 1828 88 0.23 / 746.63 2 2
3 12 2005.92 54 8.45 3077 1404 1.63 / 748.04 2 2
4 7 2002.56 24 11.05 3139 832 2.47 / 748.87 2 2
5 13 1877.28 48 11.84 2955 1679 4.15 / 750.55 2 2
6 13 895.40 48 12.99 1617 1008 5.15 / 751.56 2 2
7 13 86.64 48 14.14 415 282 5.44 / 751.84 2 2
8 8 -0.08 160 14.29 282 645 6.08 / 752.49 2 2
Average= 4.73 (KJ/cycle)

Cycle 157 GMT 8/ 1/2021 18:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 23 14.33 427 141 0.14 / 741.19 2 2
2 12 1111.28 6 9.00 1851 100 0.24 / 741.29 2 2
3 12 2005.76 54 8.81 3064 1458 1.70 / 742.75 2 2
4 7 2001.48 24 11.10 3149 839 2.54 / 743.59 2 2
5 13 1583.36 48 12.21 2549 1494 4.03 / 745.08 2 2
6 13 491.76 48 13.45 1045 675 4.71 / 745.76 2 2
7 8 0.00 160 14.28 284 649 5.35 / 746.40 2 2
Average= 4.72 (KJ/cycle)

Cycle 156 GMT 29/12/2020 18:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 23 14.33 431 142 0.14 / 736.00 2 2
2 12 1110.60 6 9.33 1879 105 0.25 / 736.10 2 2
3 12 2001.64 54 9.08 3053 1497 1.74 / 737.60 2 2
4 7 1997.64 24 11.13 3133 837 2.58 / 738.44 2 2
5 13 1466.08 48 12.37 2370 1407 3.99 / 739.84 2 2
6 13 373.64 48 13.61 866 566 4.55 / 740.41 2 2
7 8 -0.12 160 14.27 281 642 5.20 / 741.05 2 2
Average= 4.72 (KJ/cycle)

Cycle 155 GMT 19/12/2020 18:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 22 14.33 425 134 0.13 / 730.51 2 2
2 12 1115.12 5 8.92 1883 84 0.22 / 730.59 2 2
3 12 2000.80 55 9.25 3059 1556 1.77 / 732.15 2 2
4 7 1996.28 24 11.11 3131 835 2.61 / 732.98 2 2
5 13 1721.08 48 12.09 2725 1581 4.19 / 734.57 2 2
6 13 473.28 48 13.47 1023 661 4.85 / 735.23 2 2
7 8 -0.12 160 14.30 274 627 5.48 / 735.85 2 2
Average= 4.72 (KJ/cycle)

Cycle 154 GMT 9/12/2020 19:14: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 23 14.33 423 139 0.14 / 725.23 2 2
2 12 1093.32 5 8.71 1819 79 0.22 / 725.30 2 2
3 12 2002.52 55 9.01 3053 1513 1.73 / 726.82 2 2
4 7 1998.24 24 11.13 3137 838 2.57 / 727.66 2 2
5 13 1459.52 48 12.35 2360 1399 3.97 / 729.05 2 2
6 13 520.52 48 13.42 1079 695 4.66 / 729.75 2 2
7 8 0.20 160 14.28 274 626 5.29 / 730.38 2 2
Average= 4.71 (KJ/cycle)

Cycle 153 GMT 29/11/2020 19:18:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 23 14.35 424 140 0.14 / 719.87 2 2
2 12 1113.08 5 8.89 1868 83 0.22 / 719.95 2 2
3 12 2001.72 55 9.17 3053 1540 1.76 / 721.49 2 2
4 7 1997.16 24 11.13 3128 836 2.60 / 722.33 2 2
5 13 1582.88 48 12.21 2544 1491 4.09 / 723.82 2 2
6 13 448.00 48 13.49 982 636 4.73 / 724.46 2 2
7 8 0.72 160 14.28 276 631 5.36 / 725.09 2 2
Average= 4.71 (KJ/cycle)

Cycle 152 GMT 19/11/2020 19:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 23 14.33 425 140 0.14 / 714.64 2 2
2 12 1097.84 5 9.83 1852 91 0.23 / 714.73 2 2
3 12 2001.20 53 9.28 3043 1497 1.73 / 716.22 2 2
4 7 1996.84 24 11.19 3148 845 2.57 / 717.07 2 2
5 13 1585.00 36 12.43 2537 1135 3.71 / 718.20 2 2
6 13 792.12 36 13.20 1473 700 4.41 / 718.90 2 2
7 13 74.60 36 14.17 392 200 4.61 / 719.10 2 2
8 8 -0.64 160 14.28 274 626 5.23 / 719.73 2 2
Average= 4.70 (KJ/cycle)

Cycle 151 GMT 9/11/2020 19:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 24 14.34 419 144 0.14 / 709.37 2 2
2 12 1096.28 5 9.63 1858 89 0.23 / 709.46 2 2
3 12 2006.32 53 9.34 3057 1513 1.75 / 710.97 2 2
4 7 2001.96 24 11.16 3141 841 2.59 / 711.82 2 2
5 13 1734.80 36 12.29 2762 1222 3.81 / 713.04 2 2
6 13 643.12 36 13.34 1255 603 4.41 / 713.64 2 2
7 13 96.20 36 14.11 430 218 4.63 / 713.86 2 2
8 8 -0.16 160 14.27 279 637 5.27 / 714.50 2 2
Average= 4.70 (KJ/cycle)

Cycle 150 GMT 30/10/2020 19:23:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 24 14.34 431 148 0.15 / 704.29 2 2
2 3 955.76 -1 15.20 0 0 0.00 / 704.29 2 2
3 3 1044.08 1 12.37 1827 23 0.17 / 704.32 2 2
4 12 1136.64 4 8.85 1976 70 0.24 / 704.39 2 2
5 12 2007.00 53 9.62 3109 1585 1.83 / 705.97 2 2
6 7 2002.72 24 11.19 3145 845 2.67 / 706.81 2 2
7 13 1327.76 36 12.68 2214 1011 3.68 / 707.83 2 2
8 13 583.28 36 13.40 1194 576 4.26 / 708.40 2 2
9 13 71.24 36 14.19 389 199 4.46 / 708.60 2 2
10 8 0.20 160 14.30 274 627 5.08 / 709.23 2 2
Average= 4.70 (KJ/cycle)

Cycle 149 GMT 20/10/2020 19:42:58

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 24 14.34 429 148 0.15 / 699.17 2 2
2 3 953.88 -1 15.20 0 0 0.00 / 699.17 2 2
3 3 1029.64 1 12.02 1851 22 0.17 / 699.20 2 2
4 12 1128.64 4 9.32 1888 70 0.24 / 699.27 2 2
5 12 2000.04 53 9.80 3056 1587 1.83 / 700.85 2 2
6 7 1995.44 24 11.23 3120 841 2.67 / 701.69 2 2
7 13 1322.96 36 12.68 2200 1004 3.67 / 702.70 2 2
8 13 572.72 36 13.41 1174 567 4.24 / 703.27 2 2
9 13 119.12 36 14.09 467 237 4.48 / 703.50 2 2
10 8 0.12 160 14.28 281 642 5.12 / 704.14 2 2
Average= 4.69 (KJ/cycle)

Cycle 148 GMT 10/10/2020 19:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 23 14.34 430 142 0.14 / 694.10 2 2
2 10 1006.40 3 12.89 1757 68 0.21 / 694.17 2 2
3 3 959.84 -1 15.21 0 0 0.07 / 694.17 2 2
4 3 1035.36 1 12.40 1836 23 0.23 / 694.19 2 2
5 12 1133.60 2 5.68 1850 21 0.25 / 694.21 2 2
6 12 2005.76 45 9.68 3071 1338 1.59 / 695.55 2 2
7 7 2001.84 24 11.25 3153 851 2.44 / 696.40 2 2
8 13 1469.56 36 12.54 2412 1089 3.53 / 697.49 2 2
9 13 723.08 36 13.27 1378 658 4.19 / 698.15 2 2
10 13 115.68 36 14.08 465 236 4.43 / 698.39 2 2
11 8 0.16 160 14.29 280 640 5.07 / 699.03 2 2
Average= 4.69 (KJ/cycle)

Cycle 147 GMT 30/ 9/2020 20:24: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 23 14.36 425 140 0.14 / 688.95 2 2
2 12 1115.80 2 5.83 1872 22 0.16 / 688.97 2 2
3 12 2003.24 45 9.67 3057 1330 1.49 / 690.30 2 2
4 7 1999.68 25 11.28 3136 884 2.38 / 691.19 2 2
5 13 1736.84 36 12.31 2743 1216 3.59 / 692.40 2 2
6 13 814.64 36 13.18 1498 711 4.30 / 693.11 2 2
7 13 107.12 36 14.13 445 226 4.53 / 693.34 2 2
8 8 0.08 160 14.29 272 622 5.15 / 693.96 2 2
Average= 4.69 (KJ/cycle)

Cycle 146 GMT 20/ 9/2020 20:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 23 14.35 420 139 0.14 / 683.72 2 2
2 12 2025.00 40 9.38 2983 1119 1.26 / 684.84 2 2
3 7 2022.16 24 11.30 3160 857 2.11 / 685.70 2 2
4 13 1912.12 27 12.33 2999 998 3.11 / 686.70 2 2
5 13 1316.24 27 12.85 2196 762 3.88 / 687.46 2 2
6 13 542.96 27 13.49 1135 413 4.29 / 687.87 2 2
7 13 124.72 27 14.08 477 181 4.47 / 688.05 2 2
8 13 30.28 27 14.28 320 123 4.59 / 688.18 2 2
9 8 0.28 160 14.26 277 632 5.23 / 688.81 2 2
Average= 4.69 (KJ/cycle)

Cycle 145 GMT 10/ 9/2020 19:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 23 14.36 417 138 0.14 / 678.85 2 2
2 12 2003.56 40 9.95 2980 1186 1.32 / 680.04 2 2
3 7 1999.92 24 11.35 3151 858 2.18 / 680.90 2 2
4 13 1581.08 27 12.61 2553 869 3.05 / 681.76 2 2
5 13 1144.80 27 12.99 1961 688 3.74 / 682.45 2 2
6 13 377.44 27 13.67 885 327 4.07 / 682.78 2 2
7 13 117.48 27 14.09 469 178 4.24 / 682.96 2 2
8 8 0.24 160 14.28 274 626 4.87 / 683.58 2 2
Average= 4.68 (KJ/cycle)

Cycle 144 GMT 31/ 8/2020 19:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 23 14.36 420 139 0.14 / 673.77 2 2
2 12 2002.72 40 9.69 2974 1153 1.29 / 674.92 2 2
3 7 1999.76 24 11.36 3128 853 2.14 / 675.77 2 2
4 13 1875.48 27 12.36 2962 988 3.13 / 676.76 2 2
5 13 1402.88 27 12.78 2306 796 3.93 / 677.56 2 2
6 13 467.64 27 13.57 1013 371 4.30 / 677.93 2 2
7 13 94.40 27 14.15 419 160 4.46 / 678.09 2 2
8 8 0.04 160 14.29 273 624 5.08 / 678.71 2 2
Average= 4.68 (KJ/cycle)

Cycle 143 GMT 21/ 8/2020 20:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 24 14.35 425 146 0.15 / 668.74 2 2
2 12 2002.44 40 9.83 2959 1163 1.31 / 669.91 2 2
3 7 1998.80 24 11.34 3134 853 2.16 / 670.76 2 2
4 13 1860.92 27 12.37 2949 985 3.15 / 671.74 2 2
5 13 1239.96 27 12.90 2105 733 3.88 / 672.48 2 2
6 13 461.08 27 13.59 1004 368 4.25 / 672.85 2 2
7 13 85.52 27 14.16 409 156 4.41 / 673.00 2 2
8 8 0.20 160 14.27 275 628 5.03 / 673.63 2 2
Average= 4.68 (KJ/cycle)

Cycle 142 GMT 11/ 8/2020 20:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 24 14.35 422 145 0.15 / 663.63 2 2
2 3 961.80 -1 15.21 0 0 0.00 / 663.63 2 2
3 3 1054.56 1 12.42 1848 23 0.17 / 663.66 2 2
4 12 2000.64 40 9.90 3006 1190 1.36 / 664.85 2 2
5 7 1996.88 24 11.38 3121 852 2.21 / 665.70 2 2
6 13 1852.88 27 12.41 2949 988 3.20 / 666.69 2 2
7 13 1235.36 27 12.92 2084 727 3.93 / 667.41 2 2
8 13 440.48 27 13.60 984 361 4.29 / 667.78 2 2
9 13 138.04 27 14.05 502 190 4.48 / 667.97 2 2
10 8 0.12 160 14.27 276 630 5.11 / 668.60 2 2
Average= 4.68 (KJ/cycle)

Cycle 141 GMT 1/ 8/2020 20:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 23 14.36 429 142 0.14 / 658.61 2 2
2 3 1024.28 1 12.00 1930 23 0.16 / 658.64 2 2
3 12 2003.36 40 10.18 3002 1222 1.39 / 659.86 2 2
4 7 1999.76 24 11.36 3127 853 2.24 / 660.71 2 2
5 13 1857.60 27 12.40 2932 982 3.22 / 661.69 2 2
6 13 1072.36 27 13.05 1847 651 3.87 / 662.34 2 2
7 13 456.16 27 13.60 989 363 4.24 / 662.71 2 2
8 13 84.52 27 14.17 404 155 4.39 / 662.86 2 2
9 8 0.16 160 14.27 274 626 5.02 / 663.49 2 2
Average= 4.67 (KJ/cycle)

Cycle 140 GMT 22/ 7/2020 21:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 23 14.35 415 137 0.14 / 653.58 2 2
2 12 2003.00 40 10.06 3016 1214 1.35 / 654.79 2 2
3 7 1999.36 24 11.35 3153 859 2.21 / 655.65 2 2
4 13 1862.12 27 12.36 2948 984 3.19 / 656.64 2 2
5 13 1100.24 27 13.03 1889 665 3.86 / 657.30 2 2
6 13 466.76 27 13.58 1014 372 4.23 / 657.67 2 2
7 13 84.56 27 14.16 417 159 4.39 / 657.83 2 2
8 8 0.20 160 14.26 281 641 5.03 / 658.47 2 2
Average= 4.67 (KJ/cycle)

Cycle 139 GMT 12/ 7/2020 21:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 23 14.36 411 136 0.14 / 648.58 2 2
2 12 2002.36 40 10.02 3008 1206 1.34 / 649.79 2 2
3 7 1998.60 24 11.32 3143 854 2.20 / 650.64 2 2
4 13 1869.28 27 12.37 2939 982 3.18 / 651.62 2 2
5 13 1114.84 27 13.00 1909 670 3.85 / 652.29 2 2
6 13 501.72 27 13.55 1055 386 4.23 / 652.68 2 2
7 13 95.04 27 14.15 415 159 4.39 / 652.84 2 2
8 8 -0.28 160 14.29 265 606 5.00 / 653.44 2 2
Average= 4.67 (KJ/cycle)

Cycle 138 GMT 2/ 7/2020 21:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 22 14.33 424 134 0.13 / 643.41 2 2
2 12 2007.36 40 10.24 3015 1235 1.37 / 644.65 2 2
3 7 2003.76 24 11.36 3137 855 2.22 / 645.50 2 2
4 13 1863.12 27 12.38 2938 982 3.21 / 646.48 2 2
5 13 1398.80 27 12.78 2314 798 4.00 / 647.28 2 2
6 13 445.52 27 13.61 972 357 4.36 / 647.64 2 2
7 13 137.20 27 14.05 493 187 4.55 / 647.83 2 2
8 8 0.04 160 14.27 271 619 5.17 / 648.44 2 2
Average= 4.67 (KJ/cycle)

Cycle 137 GMT 22/ 6/2020 21:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 22 14.36 420 133 0.13 / 638.45 2 2
2 12 2007.12 40 10.15 3013 1223 1.36 / 639.67 2 2
3 7 2003.56 25 11.33 3123 885 2.24 / 640.55 2 2
4 13 1728.12 27 12.53 2750 930 3.17 / 641.48 2 2
5 13 1116.28 27 12.99 1907 669 3.84 / 642.15 2 2
6 13 350.00 27 13.70 857 317 4.16 / 642.47 2 2
7 13 101.28 27 14.12 443 169 4.33 / 642.64 2 2
8 8 0.64 160 14.24 280 638 4.96 / 643.28 2 2
Average= 4.66 (KJ/cycle)

Cycle 136 GMT 12/ 6/2020 22: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 22 14.35 423 134 0.13 / 633.44 2 2
2 12 1939.32 40 10.16 2902 1179 1.31 / 634.62 2 2
3 7 1935.52 24 11.34 3051 830 2.14 / 635.45 2 2
4 13 1794.80 27 12.41 2844 953 3.10 / 636.40 2 2
5 13 1319.88 27 12.83 2195 760 3.86 / 637.16 2 2
6 13 483.20 27 13.56 1031 377 4.23 / 637.54 2 2
7 13 97.20 27 14.15 424 162 4.40 / 637.70 2 2
8 8 0.28 160 14.29 268 613 5.01 / 638.31 2 2
Average= 4.66 (KJ/cycle)

Cycle 135 GMT 2/ 6/2020 21:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 22 14.34 423 133 0.13 / 628.87 2 2
2 12 1730.20 40 10.41 2655 1106 1.24 / 629.98 2 2
3 7 1727.24 24 11.54 2753 762 2.00 / 630.74 2 2
4 13 1592.36 27 12.56 2555 866 2.87 / 631.61 2 2
5 13 979.40 27 13.12 1707 605 3.47 / 632.21 2 2
6 13 359.52 27 13.70 852 315 3.79 / 632.53 2 2
7 13 96.96 27 14.13 426 163 3.95 / 632.69 2 2
8 8 -0.12 160 14.25 270 616 4.57 / 633.30 2 2
Average= 4.66 (KJ/cycle)

Cycle 134 GMT 23/ 5/2020 20:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 22 14.34 424 134 0.13 / 624.08 2 2
2 12 1952.00 40 10.26 2938 1206 1.34 / 625.29 2 2
3 7 1948.20 24 11.36 3059 834 2.17 / 626.12 2 2
4 13 1664.92 27 12.57 2661 903 3.08 / 627.02 2 2
5 13 1055.52 27 13.06 1836 647 3.72 / 627.67 2 2
6 13 292.88 27 13.78 765 285 4.01 / 627.95 2 2
7 13 81.40 27 14.19 399 153 4.16 / 628.11 2 2
8 8 0.12 160 14.26 277 632 4.79 / 628.74 2 2
Average= 4.66 (KJ/cycle)

Cycle 133 GMT 13/ 5/2020 19:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 22 14.33 433 137 0.14 / 619.08 2 2
2 12 2000.68 40 10.36 3046 1262 1.40 / 620.34 2 2
3 7 1996.64 24 11.39 3148 861 2.26 / 621.20 2 2
4 13 1708.44 27 12.53 2728 923 3.18 / 622.13 2 2
5 13 1094.28 27 13.03 1896 667 3.85 / 622.79 2 2
6 13 447.56 27 13.61 986 362 4.21 / 623.16 2 2
7 13 75.32 27 14.18 400 153 4.36 / 623.31 2 2
8 8 -0.20 160 14.25 279 636 5.00 / 623.95 2 2
Average= 4.66 (KJ/cycle)

Cycle 132 GMT 3/ 5/2020 20:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 22 14.36 422 133 0.13 / 613.92 2 2
2 12 2002.40 40 10.36 3009 1247 1.38 / 615.17 2 2
3 7 1998.28 24 11.34 3112 847 2.23 / 616.02 2 2
4 13 1857.28 27 12.40 2918 977 3.20 / 616.99 2 2
5 13 1092.76 27 13.04 1875 660 3.86 / 617.65 2 2
6 13 619.28 27 13.45 1225 445 4.31 / 618.10 2 2
7 13 132.76 27 14.05 499 189 4.50 / 618.29 2 2
8 8 0.20 160 14.22 289 658 5.16 / 618.94 2 2
Average= 4.65 (KJ/cycle)

Cycle 131 GMT 23/ 4/2020 20:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 22 14.34 425 134 0.13 / 608.99 2 2
2 12 2002.68 40 10.32 3029 1250 1.38 / 610.24 2 2
3 7 1998.72 24 11.39 3119 853 2.24 / 611.10 2 2
4 13 1713.32 27 12.54 2737 927 3.16 / 612.02 2 2
5 13 1098.76 27 13.05 1879 662 3.83 / 612.68 2 2
6 13 333.20 27 13.75 809 300 4.13 / 612.98 2 2
7 13 98.36 27 14.15 433 165 4.29 / 613.15 2 2
8 8 0.08 160 14.25 280 638 4.93 / 613.79 2 2
Average= 4.65 (KJ/cycle)

Cycle 130 GMT 13/ 4/2020 20:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 22 14.35 421 133 0.13 / 604.05 2 2
2 12 2000.64 40 10.40 3032 1261 1.39 / 605.31 2 2
3 7 1996.88 24 11.41 3132 858 2.25 / 606.17 2 2
4 13 1707.60 27 12.55 2726 924 3.18 / 607.10 2 2
5 13 1094.24 27 13.06 1878 662 3.84 / 607.76 2 2
6 13 309.16 27 13.77 790 294 4.13 / 608.05 2 2
7 13 81.72 27 14.16 413 158 4.29 / 608.21 2 2
8 8 0.04 160 14.23 285 649 4.94 / 608.86 2 2
Average= 4.65 (KJ/cycle)

Cycle 129 GMT 3/ 4/2020 21:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 22 14.32 438 138 0.14 / 598.86 2 2
2 12 2008.56 40 10.37 3030 1257 1.39 / 600.12 2 2
3 7 2004.52 24 11.36 3153 860 2.25 / 600.98 2 2
4 13 1862.44 27 12.41 2926 980 3.23 / 601.96 2 2
5 13 1384.76 27 12.81 2290 792 4.03 / 602.75 2 2
6 13 424.28 27 13.64 947 349 4.38 / 603.10 2 2
7 13 133.00 27 14.07 486 185 4.56 / 603.29 2 2
8 8 -0.04 160 14.25 278 634 5.19 / 603.92 2 2
Average= 4.65 (KJ/cycle)

Cycle 128 GMT 24/ 3/2020 20:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 22 14.34 426 134 0.13 / 593.64 2 2
2 12 2005.48 40 10.52 3051 1284 1.42 / 594.93 2 2
3 7 2001.08 24 11.40 3139 859 2.28 / 595.79 2 2
4 13 1861.64 27 12.40 2947 987 3.26 / 596.77 2 2
5 13 1190.04 27 12.96 2038 713 3.98 / 597.49 2 2
6 13 522.92 27 13.54 1107 405 4.38 / 597.89 2 2
7 13 103.24 27 14.11 461 176 4.56 / 598.07 2 2
8 8 0.04 160 14.23 290 660 5.22 / 598.73 2 2
Average= 4.64 (KJ/cycle)

Cycle 127 GMT 14/ 3/2020 21:46: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 22 14.34 425 134 0.13 / 588.74 2 2
2 12 2006.00 40 10.39 3039 1263 1.40 / 590.00 2 2
3 7 2002.04 24 11.41 3138 859 2.26 / 590.86 2 2
4 13 1711.80 27 12.55 2737 927 3.18 / 591.79 2 2
5 13 970.20 27 13.16 1707 607 3.79 / 592.39 2 2
6 13 347.40 27 13.73 832 308 4.10 / 592.70 2 2
7 13 98.12 27 14.14 441 168 4.27 / 592.87 2 2
8 8 0.20 160 14.24 280 638 4.91 / 593.51 2 2
Average= 4.64 (KJ/cycle)

Cycle 126 GMT 4/ 3/2020 22:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 22 14.35 436 138 0.14 / 583.52 2 2
2 12 2007.20 40 10.43 3049 1272 1.41 / 584.79 2 2
3 7 2003.56 24 11.44 3123 857 2.27 / 585.65 2 2
4 13 1866.00 27 12.41 2952 989 3.26 / 586.64 2 2
5 13 1228.32 27 12.94 2091 731 3.99 / 587.37 2 2
6 13 586.00 27 13.49 1183 431 4.42 / 587.80 2 2
7 13 116.16 27 14.10 464 177 4.59 / 587.97 2 2
8 8 0.20 160 14.25 276 629 5.22 / 588.60 2 2
Average= 4.63 (KJ/cycle)

Cycle 125 GMT 23/ 2/2020 22:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 22 14.36 424 134 0.13 / 578.45 2 2
2 12 2004.56 40 10.46 3031 1268 1.40 / 579.72 2 2
3 7 2000.52 24 11.42 3133 859 2.26 / 580.58 2 2
4 13 1857.44 27 12.42 2940 986 3.25 / 581.56 2 2
5 13 1079.44 27 13.06 1860 656 3.90 / 582.22 2 2
6 13 448.40 27 13.62 983 361 4.26 / 582.58 2 2
7 13 81.04 27 14.17 409 156 4.42 / 582.74 2 2
8 8 0.52 160 14.24 282 643 5.06 / 583.38 2 2
Average= 4.63 (KJ/cycle)

Cycle 124 GMT 13/ 2/2020 23: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 23 14.35 418 138 0.14 / 573.27 2 2
2 12 2007.28 40 10.43 3039 1268 1.41 / 574.54 2 2
3 7 2003.56 24 11.36 3132 854 2.26 / 575.39 2 2
4 13 1869.72 27 12.39 2949 987 3.25 / 576.38 2 2
5 13 1403.08 27 12.80 2303 796 4.04 / 577.18 2 2
6 13 441.80 27 13.61 978 359 4.40 / 577.54 2 2
7 13 81.76 27 14.17 403 154 4.56 / 577.69 2 2
8 8 0.40 160 14.24 275 627 5.18 / 578.32 2 2
Average= 4.63 (KJ/cycle)

Cycle 123 GMT 3/ 2/2020 23: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 22 14.34 429 135 0.14 / 568.37 2 2
2 3 1021.56 1 10.15 1907 19 0.15 / 568.39 2 2
3 12 2002.84 40 10.51 3054 1284 1.44 / 569.68 2 2
4 7 1998.32 24 11.43 3139 861 2.30 / 570.54 2 2
5 13 1716.56 27 12.53 2753 931 3.23 / 571.47 2 2
6 13 933.80 27 13.18 1659 590 3.82 / 572.06 2 2
7 13 313.68 27 13.76 782 291 4.11 / 572.35 2 2
8 13 78.20 27 14.16 403 154 4.27 / 572.50 2 2
9 8 -0.08 160 14.22 277 630 4.90 / 573.13 2 2
Average= 4.62 (KJ/cycle)

Cycle 122 GMT 24/ 1/2020 23:26: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 22 14.38 412 130 0.13 / 563.36 2 2
2 12 2001.52 40 10.54 3025 1275 1.41 / 564.64 2 2
3 7 1997.08 24 11.39 3119 853 2.26 / 565.49 2 2
4 13 1568.60 27 12.64 2571 877 3.14 / 566.37 2 2
5 13 1127.76 27 13.02 1935 680 3.82 / 567.05 2 2
6 13 494.00 27 13.56 1074 393 4.21 / 567.44 2 2
7 13 84.44 27 14.14 421 161 4.37 / 567.60 2 2
8 8 0.08 160 14.23 279 635 5.01 / 568.24 2 2
Average= 4.62 (KJ/cycle)

Cycle 121 GMT 14/ 1/2020 23:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 23 14.37 422 139 0.14 / 558.39 2 2
2 12 2003.52 40 10.43 3041 1269 1.41 / 559.66 2 2
3 7 1999.72 24 11.38 3117 851 2.26 / 560.51 2 2
4 13 1861.48 27 12.41 2926 980 3.24 / 561.49 2 2
5 13 947.04 27 13.17 1675 596 3.84 / 562.08 2 2
6 13 473.24 27 13.59 1020 374 4.21 / 562.46 2 2
7 13 80.28 27 14.17 403 154 4.36 / 562.61 2 2
8 8 0.00 160 14.25 273 622 4.99 / 563.23 2 2
Average= 4.62 (KJ/cycle)

Cycle 120 GMT 4/ 1/2020 23:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 23 14.37 421 139 0.14 / 553.35 2 2
2 12 2003.80 40 10.48 3044 1276 1.42 / 554.62 2 2
3 7 1999.40 25 11.40 3145 896 2.31 / 555.52 2 2
4 13 1700.60 27 12.55 2719 921 3.23 / 556.44 2 2
5 13 1090.56 27 13.06 1878 662 3.90 / 557.10 2 2
6 13 442.56 27 13.62 976 359 4.25 / 557.46 2 2
7 13 70.64 27 14.18 392 150 4.40 / 557.61 2 2
8 8 -0.12 160 14.23 279 635 5.04 / 558.25 2 2
Average= 4.61 (KJ/cycle)

Cycle 119 GMT 26/12/2019 0:22: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 22 14.37 421 133 0.13 / 548.34 2 2
2 12 2006.76 40 10.48 3073 1288 1.42 / 549.63 2 2
3 7 2002.92 24 11.41 3158 865 2.29 / 550.49 2 2
4 13 1863.84 27 12.40 2948 987 3.27 / 551.48 2 2
5 13 1074.20 27 13.07 1859 656 3.93 / 552.14 2 2
6 13 311.80 27 13.77 783 291 4.22 / 552.43 2 2
7 13 88.52 27 14.17 416 159 4.38 / 552.59 2 2
8 8 0.48 160 14.25 272 620 5.00 / 553.21 2 2
Average= 4.61 (KJ/cycle)

Cycle 118 GMT 16/12/2019 0:38:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 23 14.37 422 139 0.14 / 543.53 2 2
2 12 2001.80 40 10.48 3045 1276 1.42 / 544.80 2 2
3 7 1997.84 24 11.41 3136 859 2.27 / 545.66 2 2
4 13 1552.88 27 12.68 2521 863 3.14 / 546.53 2 2
5 13 958.44 27 13.17 1682 598 3.74 / 547.12 2 2
6 13 319.48 27 13.76 798 296 4.03 / 547.42 2 2
7 13 86.28 27 14.16 417 159 4.19 / 547.58 2 2
8 8 -0.16 160 14.26 275 627 4.82 / 548.21 2 2
Average= 4.61 (KJ/cycle)

Cycle 117 GMT 6/12/2019 0:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 23 14.37 425 140 0.14 / 538.45 2 2
2 12 2004.48 40 10.50 3026 1271 1.41 / 539.72 2 2
3 7 2001.08 24 11.39 3130 856 2.27 / 540.57 2 2
4 13 1861.88 27 12.40 2934 982 3.25 / 541.56 2 2
5 13 1208.60 27 12.97 2020 707 3.96 / 542.26 2 2
6 13 411.76 27 13.67 925 341 4.30 / 542.61 2 2
7 13 74.80 27 14.19 403 154 4.45 / 542.76 2 2
8 8 0.04 160 14.25 276 629 5.08 / 543.39 2 2
Average= 4.60 (KJ/cycle)

Cycle 116 GMT 26/11/2019 1: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 23 14.40 418 138 0.14 / 533.35 2 2
2 12 2002.20 40 10.50 3027 1271 1.41 / 534.63 2 2
3 7 1998.08 24 11.39 3119 853 2.26 / 535.48 2 2
4 13 1853.80 27 12.40 2922 978 3.24 / 536.46 2 2
5 13 1215.04 27 12.96 2054 719 3.96 / 537.18 2 2
6 13 402.88 27 13.68 921 340 4.30 / 537.52 2 2
7 13 122.68 27 14.12 464 177 4.48 / 537.69 2 2
8 8 0.36 160 14.27 269 614 5.09 / 538.31 2 2
Average= 4.60 (KJ/cycle)

Cycle 115 GMT 16/11/2019 1:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 22 14.40 419 133 0.13 / 528.31 2 2
2 12 2002.60 40 10.57 3052 1290 1.42 / 529.60 2 2
3 7 1999.16 24 11.47 3125 860 2.28 / 530.46 2 2
4 13 1866.04 27 12.38 2948 985 3.27 / 531.44 2 2
5 13 1072.56 27 13.08 1846 652 3.92 / 532.09 2 2
6 13 438.72 27 13.65 970 357 4.28 / 532.45 2 2
7 13 79.12 27 14.20 396 152 4.43 / 532.60 2 2
8 8 0.68 160 14.26 269 614 5.04 / 533.22 2 2
Average= 4.60 (KJ/cycle)

Cycle 114 GMT 6/11/2019 2: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 22 14.39 419 133 0.13 / 523.35 2 2
2 12 2001.08 40 10.56 3033 1281 1.41 / 524.63 2 2
3 7 1997.28 24 11.47 3136 863 2.28 / 525.49 2 2
4 13 1856.76 27 12.40 2915 976 3.25 / 526.47 2 2
5 13 1066.84 27 13.07 1843 650 3.90 / 527.12 2 2
6 13 307.76 27 13.79 768 286 4.19 / 527.40 2 2
7 13 89.24 27 14.17 416 159 4.35 / 527.56 2 2
8 8 -0.32 160 14.28 267 610 4.96 / 528.17 2 2
Average= 4.59 (KJ/cycle)

Cycle 113 GMT 27/10/2019 2:28: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 23 14.38 426 141 0.14 / 518.11 2 2
2 12 2004.56 40 10.54 3039 1281 1.42 / 519.39 2 2
3 7 2000.88 24 11.45 3130 860 2.28 / 520.25 2 2
4 13 1864.16 27 12.36 2947 983 3.27 / 521.24 2 2
5 13 1236.84 27 12.94 2069 723 3.99 / 521.96 2 2
6 13 424.80 27 13.66 948 350 4.34 / 522.31 2 2
7 13 75.88 27 14.19 394 151 4.49 / 522.46 2 2
8 13 38.44 27 14.24 330 127 4.62 / 522.59 2 2
9 8 0.20 160 14.23 275 626 5.24 / 523.21 2 2
Average= 4.59 (KJ/cycle)

Cycle 112 GMT 17/10/2019 2:34: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 23 14.39 427 141 0.14 / 513.13 2 2
2 12 2003.88 40 10.58 3042 1287 1.43 / 514.41 2 2
3 7 1999.56 24 11.44 3134 860 2.29 / 515.27 2 2
4 13 1707.12 27 12.55 2717 921 3.21 / 516.19 2 2
5 13 1093.20 27 13.04 1897 668 3.88 / 516.86 2 2
6 13 336.00 27 13.75 829 308 4.19 / 517.17 2 2
7 13 86.32 27 14.16 421 161 4.35 / 517.33 2 2
8 8 0.24 160 14.22 282 642 4.99 / 517.97 2 2
Average= 4.58 (KJ/cycle)

Cycle 111 GMT 7/10/2019 2:26: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 24 14.38 421 145 0.15 / 508.06 2 2
2 3 941.56 -1 15.27 0 0 0.00 / 508.06 2 2
3 3 1031.00 1 11.85 1830 22 0.17 / 508.08 2 2
4 12 2005.32 40 10.59 3071 1301 1.47 / 509.39 2 2
5 7 2001.64 24 11.46 3158 869 2.34 / 510.25 2 2
6 13 1873.36 27 12.36 2984 996 3.33 / 511.25 2 2
7 13 957.68 27 13.15 1706 606 3.94 / 511.86 2 2
8 13 354.84 27 13.73 859 318 4.26 / 512.17 2 2
9 13 94.08 27 14.14 443 169 4.43 / 512.34 2 2
10 8 -0.24 160 14.25 281 641 5.07 / 512.98 2 2
Average= 4.58 (KJ/cycle)

Cycle 110 GMT 27/ 9/2019 2:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 22 14.41 421 133 0.13 / 502.92 2 2
2 10 1017.52 3 12.84 1792 69 0.20 / 502.98 2 2
3 12 2003.12 40 10.54 3042 1283 1.49 / 504.27 2 2
4 7 1998.88 24 11.45 3153 866 2.35 / 505.13 2 2
5 13 1854.64 27 12.39 2927 979 3.33 / 506.11 2 2
6 13 1080.04 27 13.07 1865 658 3.99 / 506.77 2 2
7 13 438.48 27 13.64 982 362 4.35 / 507.13 2 2
8 13 74.00 27 14.19 395 151 4.50 / 507.28 2 2
9 8 -0.16 160 14.24 278 633 5.14 / 507.92 2 2
Average= 4.58 (KJ/cycle)

Cycle 109 GMT 17/ 9/2019 3: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 22 14.39 424 134 0.13 / 497.92 2 2
2 12 2001.28 40 10.64 3037 1293 1.43 / 499.22 2 2
3 7 1997.12 24 11.42 3133 859 2.29 / 500.08 2 2
4 13 1702.44 27 12.56 2707 918 3.20 / 500.99 2 2
5 13 975.72 27 13.16 1719 611 3.81 / 501.60 2 2
6 13 496.20 27 13.59 1057 388 4.20 / 501.99 2 2
7 13 78.12 27 14.17 410 157 4.36 / 502.15 2 2
8 8 0.44 160 14.23 278 633 4.99 / 502.78 2 2
Average= 4.57 (KJ/cycle)

Cycle 108 GMT 7/ 9/2019 3: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 22 14.40 424 134 0.13 / 492.94 2 2
2 12 2003.84 40 10.58 3046 1289 1.42 / 494.23 2 2
3 7 1999.84 24 11.45 3132 861 2.28 / 495.09 2 2
4 13 1862.68 27 12.39 2961 991 3.27 / 496.08 2 2
5 13 1077.00 27 13.08 1849 653 3.93 / 496.73 2 2
6 13 292.88 27 13.82 751 280 4.21 / 497.01 2 2
7 13 79.16 27 14.19 402 154 4.36 / 497.16 2 2
8 8 0.08 160 14.24 275 627 4.99 / 497.79 2 2
Average= 4.57 (KJ/cycle)

Cycle 107 GMT 28/ 8/2019 3:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 22 14.40 420 133 0.13 / 487.86 2 2
2 12 2003.40 40 10.60 3041 1289 1.42 / 489.15 2 2
3 7 1999.52 24 11.51 3122 862 2.28 / 490.01 2 2
4 13 1858.00 27 12.40 2938 984 3.27 / 490.99 2 2
5 13 1086.56 27 13.06 1888 666 3.93 / 491.66 2 2
6 13 451.24 27 13.64 998 368 4.30 / 492.02 2 2
7 13 77.32 27 14.21 403 155 4.46 / 492.18 2 2
8 8 0.04 160 14.26 273 623 5.08 / 492.80 2 2
Average= 4.56 (KJ/cycle)

Cycle 106 GMT 18/ 8/2019 3:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 23 14.40 424 140 0.14 / 482.85 2 2
2 12 2006.36 40 10.60 3043 1290 1.43 / 484.14 2 2
3 7 2002.72 24 11.48 3141 865 2.30 / 485.01 2 2
4 13 1861.44 27 12.40 2935 983 3.28 / 485.99 2 2
5 13 1083.72 27 13.08 1863 658 3.94 / 486.65 2 2
6 13 309.60 27 13.81 779 290 4.23 / 486.94 2 2
7 13 83.12 27 14.18 411 157 4.38 / 487.09 2 2
8 8 0.08 160 14.24 276 629 5.01 / 487.72 2 2
Average= 4.56 (KJ/cycle)

Cycle 105 GMT 8/ 8/2019 4: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 22 14.42 423 134 0.13 / 477.89 2 2
2 12 2001.24 40 10.70 3080 1318 1.45 / 479.21 2 2
3 7 1996.80 24 11.52 3149 871 2.32 / 480.08 2 2
4 13 1697.72 27 12.59 2721 925 3.25 / 481.01 2 2
5 13 933.20 27 13.20 1673 596 3.84 / 481.60 2 2
6 13 325.00 27 13.77 831 309 4.15 / 481.91 2 2
7 13 80.56 27 14.18 417 160 4.31 / 482.07 2 2
8 8 0.08 160 14.22 281 639 4.95 / 482.71 2 2
Average= 4.55 (KJ/cycle)

Cycle 104 GMT 29/ 7/2019 4: 9: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 22 14.41 421 133 0.13 / 472.86 2 2
2 12 2005.24 40 10.63 3046 1295 1.43 / 474.15 2 2
3 7 2001.20 24 11.51 3125 863 2.29 / 475.02 2 2
4 13 1860.20 27 12.40 2958 990 3.28 / 476.01 2 2
5 13 1089.04 27 13.08 1870 660 3.94 / 476.67 2 2
6 13 304.24 27 13.80 786 293 4.24 / 476.96 2 2
7 13 80.00 27 14.18 417 160 4.40 / 477.12 2 2
8 8 0.28 160 14.25 280 638 5.03 / 477.76 2 2
Average= 4.55 (KJ/cycle)

Cycle 103 GMT 19/ 7/2019 4:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 22 14.40 412 131 0.13 / 467.98 2 2
2 3 1020.16 1 10.56 1871 20 0.15 / 468.00 2 2
3 12 2003.04 40 10.69 3062 1309 1.46 / 469.31 2 2
4 7 1999.32 24 11.51 3136 866 2.33 / 470.18 2 2
5 13 1712.32 27 12.56 2737 928 3.25 / 471.10 2 2
6 13 951.76 27 13.19 1685 600 3.85 / 471.70 2 2
7 13 208.16 27 13.96 615 232 4.09 / 471.94 2 2
8 13 56.56 27 14.23 375 144 4.23 / 472.08 2 2
9 8 -0.28 160 14.23 283 644 4.87 / 472.72 2 2
Average= 4.55 (KJ/cycle)

Cycle 102 GMT 9/ 7/2019 4:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 22 14.39 420 133 0.13 / 463.04 2 2
2 12 1999.60 40 10.72 3055 1310 1.44 / 464.35 2 2
3 7 1994.88 24 11.55 3130 868 2.31 / 465.22 2 2
4 13 1716.36 27 12.55 2753 933 3.24 / 466.15 2 2
5 13 1061.84 27 13.11 1827 647 3.89 / 466.80 2 2
6 13 267.08 27 13.86 715 268 4.16 / 467.07 2 2
7 13 61.80 27 14.21 377 145 4.30 / 467.21 2 2
8 8 -0.04 160 14.22 280 637 4.94 / 467.85 2 2
Average= 4.54 (KJ/cycle)

Cycle 101 GMT 29/ 6/2019 4:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 22 14.40 422 134 0.13 / 457.93 2 2
2 12 2007.36 40 10.68 3052 1304 1.44 / 459.24 2 2
3 7 2003.40 24 11.51 3145 869 2.31 / 460.11 2 2
4 13 1862.00 27 12.41 2927 981 3.29 / 461.09 2 2
5 13 1079.76 27 13.09 1870 661 3.95 / 461.75 2 2
6 13 447.44 27 13.65 996 367 4.32 / 462.12 2 2
7 13 63.24 27 14.19 388 149 4.46 / 462.26 2 2
8 8 -0.04 160 14.20 284 645 5.11 / 462.91 2 2
Average= 4.54 (KJ/cycle)

Cycle 100 GMT 19/ 6/2019 4:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 22 14.40 427 135 0.14 / 453.01 2 2
2 12 2003.20 40 10.69 3047 1303 1.44 / 454.31 2 2
3 7 1998.96 24 11.50 3149 869 2.31 / 455.18 2 2
4 13 1715.32 27 12.58 2737 930 3.24 / 456.11 2 2
5 13 947.84 27 13.21 1679 599 3.84 / 456.71 2 2
6 13 322.24 27 13.80 806 300 4.14 / 457.01 2 2
7 13 42.72 27 14.25 356 137 4.27 / 457.15 2 2
8 8 -0.04 160 14.18 288 653 4.93 / 457.80 2 2
Average= 4.53 (KJ/cycle)

Cycle 99 GMT 9/ 6/2019 5:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 22 14.41 419 133 0.13 / 447.99 2 2
2 12 2005.08 40 10.80 3022 1306 1.44 / 449.30 2 2
3 7 2001.08 24 11.56 3141 871 2.31 / 450.17 2 2
4 13 1711.76 27 12.58 2721 924 3.23 / 451.09 2 2
5 13 1096.56 27 13.08 1908 674 3.91 / 451.77 2 2
6 13 297.32 27 13.82 791 295 4.20 / 452.06 2 2
7 13 72.00 27 14.20 407 156 4.36 / 452.22 2 2
8 8 0.12 160 14.21 288 655 5.01 / 452.87 2 2
Average= 4.53 (KJ/cycle)

Cycle 98 GMT 30/ 5/2019 5:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 21 14.40 431 130 0.13 / 442.87 2 2
2 12 2004.36 40 10.76 3053 1314 1.44 / 444.19 2 2
3 7 2000.80 24 11.58 3131 870 2.31 / 445.06 2 2
4 13 1863.20 27 12.46 2939 989 3.30 / 446.05 2 2
5 13 1084.24 27 13.10 1884 666 3.97 / 446.71 2 2
6 13 423.28 27 13.70 963 356 4.33 / 447.07 2 2
7 13 60.48 27 14.23 381 146 4.47 / 447.22 2 2
8 8 0.28 160 14.22 283 644 5.12 / 447.86 2 2
Average= 4.52 (KJ/cycle)

Cycle 97 GMT 20/ 5/2019 5:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 21 14.41 420 127 0.13 / 437.90 2 2
2 12 2000.52 40 10.76 3048 1312 1.44 / 439.21 2 2
3 7 1996.32 24 11.64 3120 872 2.31 / 440.08 2 2
4 13 1706.20 27 12.60 2729 928 3.24 / 441.01 2 2
5 13 1079.52 27 13.11 1878 665 3.90 / 441.68 2 2
6 13 290.88 27 13.84 777 290 4.19 / 441.97 2 2
7 13 39.88 27 14.28 345 133 4.33 / 442.10 2 2
8 8 -0.44 160 14.21 284 646 4.97 / 442.74 2 2
Average= 4.52 (KJ/cycle)

Cycle 96 GMT 10/ 5/2019 6: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 22 14.40 413 131 0.13 / 432.92 2 2
2 12 2002.04 40 10.77 3028 1304 1.44 / 434.23 2 2
3 7 1997.88 24 11.63 3126 873 2.31 / 435.10 2 2
4 13 1856.12 27 12.45 2942 989 3.30 / 436.09 2 2
5 13 943.44 27 13.22 1684 601 3.90 / 436.69 2 2
6 13 316.64 27 13.83 794 296 4.19 / 436.99 2 2
7 13 76.20 27 14.21 402 154 4.35 / 437.14 2 2
8 8 -0.08 160 14.22 278 633 4.98 / 437.77 2 2
Average= 4.51 (KJ/cycle)

Cycle 95 GMT 30/ 4/2019 6:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 22 14.42 421 134 0.13 / 427.97 2 2
2 12 2002.64 40 10.77 3032 1306 1.44 / 429.28 2 2
3 7 1998.52 24 11.64 3124 873 2.31 / 430.15 2 2
4 13 1855.48 27 12.48 2928 987 3.30 / 431.14 2 2
5 13 929.52 27 13.25 1663 595 3.89 / 431.73 2 2
6 13 300.52 27 13.86 757 283 4.18 / 432.02 2 2
7 13 69.92 27 14.23 381 146 4.32 / 432.16 2 2
8 8 0.32 160 14.23 276 628 4.95 / 432.79 2 2
Average= 4.51 (KJ/cycle)

Cycle 94 GMT 20/ 4/2019 6:42: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 21 14.41 426 129 0.13 / 422.92 2 2
2 12 2004.84 40 10.77 3058 1317 1.45 / 424.23 2 2
3 7 2001.04 24 11.59 3142 874 2.32 / 425.11 2 2
4 13 1863.12 27 12.48 2955 996 3.32 / 426.10 2 2
5 13 1081.72 27 13.14 1857 659 3.97 / 426.76 2 2
6 13 314.88 27 13.86 785 294 4.27 / 427.06 2 2
7 13 83.48 27 14.22 407 156 4.42 / 427.21 2 2
8 8 -0.20 160 14.26 274 625 5.05 / 427.84 2 2
Average= 4.50 (KJ/cycle)

Cycle 93 GMT 10/ 4/2019 7: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 22 14.43 418 133 0.13 / 417.73 2 2
2 12 2009.40 40 10.77 3027 1304 1.44 / 419.03 2 2
3 7 2005.36 24 11.66 3148 881 2.32 / 419.91 2 2
4 13 1869.88 27 12.47 2992 1007 3.33 / 420.92 2 2
5 13 1095.80 27 13.13 1880 666 3.99 / 421.59 2 2
6 13 454.88 27 13.70 1009 373 4.36 / 421.96 2 2
7 13 138.20 27 14.12 503 192 4.56 / 422.15 2 2
8 8 -0.28 160 14.23 279 635 5.19 / 422.79 2 2
Average= 4.50 (KJ/cycle)

Cycle 92 GMT 31/ 3/2019 6:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 21 14.42 428 130 0.13 / 412.57 2 2
2 3 1028.44 1 12.18 1832 22 0.15 / 412.59 2 2
3 12 2003.28 40 10.82 3050 1320 1.47 / 413.91 2 2
4 7 1999.16 24 11.65 3128 875 2.35 / 414.79 2 2
5 13 1855.76 27 12.51 2917 985 3.33 / 415.77 2 2
6 13 1213.64 27 13.05 2038 718 4.05 / 416.49 2 2
7 13 376.84 27 13.78 894 333 4.38 / 416.82 2 2
8 13 59.48 27 14.27 369 142 4.52 / 416.97 2 2
9 8 0.08 160 14.25 277 632 5.16 / 417.60 2 2
Average= 4.49 (KJ/cycle)

Cycle 91 GMT 21/ 3/2019 7:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 21 14.44 413 125 0.13 / 407.62 2 2
2 12 1999.92 40 10.85 3054 1325 1.45 / 408.94 2 2
3 7 1995.40 24 11.69 3131 878 2.33 / 409.82 2 2
4 13 1712.24 27 12.65 2756 941 3.27 / 410.76 2 2
5 13 938.68 27 13.27 1687 604 3.87 / 411.37 2 2
6 13 308.84 27 13.86 779 292 4.17 / 411.66 2 2
7 13 71.80 27 14.25 386 149 4.31 / 411.81 2 2
8 8 -0.24 160 14.23 279 635 4.95 / 412.44 2 2
Average= 4.48 (KJ/cycle)

Cycle 90 GMT 11/ 3/2019 7:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 21 14.43 408 124 0.12 / 402.58 2 2
2 12 2010.84 40 10.84 3032 1315 1.44 / 403.90 2 2
3 7 2007.68 24 11.66 3145 880 2.32 / 404.78 2 2
4 13 1880.76 27 12.49 2957 997 3.32 / 405.78 2 2
5 13 1067.44 27 13.16 1849 657 3.97 / 406.43 2 2
6 13 296.24 27 13.89 753 282 4.25 / 406.72 2 2
7 13 76.64 27 14.24 390 150 4.40 / 406.87 2 2
8 8 0.08 160 14.24 274 624 5.03 / 407.49 2 2
Average= 4.48 (KJ/cycle)

Cycle 89 GMT 1/ 3/2019 7:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 21 14.44 409 124 0.12 / 397.35 2 2
2 12 2005.12 40 10.79 3029 1307 1.43 / 398.66 2 2
3 7 2001.20 24 11.67 3124 875 2.31 / 399.54 2 2
4 13 1858.84 27 12.50 2971 1003 3.31 / 400.54 2 2
5 13 1382.52 27 12.94 2282 797 4.11 / 401.34 2 2
6 13 386.92 27 13.78 890 331 4.44 / 401.67 2 2
7 13 115.56 27 14.17 455 174 4.61 / 401.84 2 2
8 8 0.24 160 14.27 272 621 5.23 / 402.46 2 2
Average= 4.47 (KJ/cycle)

Cycle 88 GMT 19/ 2/2019 8:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 21 14.43 413 125 0.13 / 392.41 2 2
2 12 2000.16 40 10.76 3023 1301 1.43 / 393.71 2 2
3 7 1995.68 24 11.68 3131 878 2.30 / 394.59 2 2
4 13 1703.52 27 12.70 2711 930 3.23 / 395.52 2 2
5 13 1090.48 27 13.17 1882 669 3.90 / 396.19 2 2
6 13 296.44 27 13.90 750 281 4.18 / 396.47 2 2
7 13 74.24 27 14.27 380 146 4.33 / 396.62 2 2
8 8 0.08 160 14.27 268 612 4.94 / 397.23 2 2
Average= 4.46 (KJ/cycle)

Cycle 87 GMT 9/ 2/2019 8:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 21 14.44 419 127 0.13 / 387.38 2 2
2 12 2002.60 40 10.80 3045 1315 1.44 / 388.70 2 2
3 7 1998.44 24 11.72 3138 883 2.33 / 389.58 2 2
4 13 1858.92 27 12.54 2938 995 3.32 / 390.57 2 2
5 13 1078.32 27 13.19 1860 662 3.98 / 391.24 2 2
6 13 299.28 27 13.90 756 284 4.27 / 391.52 2 2
7 13 75.24 27 14.27 387 149 4.42 / 391.67 2 2
8 8 0.56 160 14.26 270 616 5.03 / 392.29 2 2
Average= 4.46 (KJ/cycle)

Cycle 86 GMT 30/ 1/2019 9:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 21 14.45 413 125 0.13 / 382.41 2 2
2 12 2011.04 40 10.72 3060 1312 1.44 / 383.72 2 2
3 7 2007.48 24 11.71 3135 881 2.32 / 384.60 2 2
4 13 1872.24 27 12.55 2955 1001 3.32 / 385.61 2 2
5 13 918.72 27 13.32 1635 588 3.91 / 386.19 2 2
6 13 298.36 27 13.90 763 286 4.19 / 386.48 2 2
7 13 79.04 27 14.26 395 152 4.35 / 386.63 2 2
8 8 -0.28 160 14.26 273 623 4.97 / 387.26 2 2
Average= 4.45 (KJ/cycle)

Cycle 85 GMT 20/ 1/2019 9:24: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 22 14.45 411 131 0.13 / 377.51 2 2
2 12 2005.00 40 10.68 3036 1297 1.43 / 378.81 2 2
3 7 2001.32 24 11.66 3129 876 2.30 / 379.69 2 2
4 13 1868.32 27 12.53 2940 995 3.30 / 380.68 2 2
5 13 783.84 27 13.43 1447 525 3.82 / 381.20 2 2
6 13 328.36 27 13.88 797 299 4.12 / 381.50 2 2
7 13 90.12 27 14.23 421 162 4.28 / 381.67 2 2
8 8 0.20 160 14.26 272 621 4.90 / 382.29 2 2
Average= 4.45 (KJ/cycle)

Cycle 84 GMT 10/ 1/2019 9:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 22 14.46 414 132 0.13 / 372.69 2 2
2 12 2005.84 40 10.71 3039 1302 1.43 / 373.99 2 2
3 7 2001.44 24 11.71 3127 879 2.31 / 374.87 2 2
4 13 1556.64 27 12.83 2511 870 3.18 / 375.74 2 2
5 13 945.20 27 13.32 1663 598 3.78 / 376.34 2 2
6 13 308.72 27 13.91 767 288 4.07 / 376.62 2 2
7 13 79.64 27 14.27 388 149 4.22 / 376.77 2 2
8 8 0.36 160 14.27 267 610 4.83 / 377.38 2 2
Average= 4.44 (KJ/cycle)

Cycle 83 GMT 31/12/2018 9:18:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 22 14.46 425 135 0.14 / 367.65 2 2
2 12 2007.20 40 10.75 3063 1317 1.45 / 368.97 2 2
3 7 2003.20 24 11.71 3127 879 2.33 / 369.85 2 2
4 13 1865.68 27 12.58 2942 999 3.33 / 370.85 2 2
5 13 1088.48 27 13.21 1859 663 3.99 / 371.51 2 2
6 13 299.04 27 13.92 752 283 4.28 / 371.79 2 2
7 13 80.08 27 14.27 390 150 4.43 / 371.94 2 2
8 8 0.32 160 14.28 267 610 5.04 / 372.55 2 2
Average= 4.44 (KJ/cycle)

Cycle 82 GMT 21/12/2018 9:30:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 21 14.48 420 128 0.13 / 362.64 2 2
2 12 2002.00 40 10.83 3045 1319 1.45 / 363.96 2 2
3 7 1997.48 24 11.69 3122 876 2.32 / 364.84 2 2
4 13 1855.84 27 12.57 2928 994 3.32 / 365.83 2 2
5 13 1054.20 27 13.24 1828 653 3.97 / 366.49 2 2
6 13 271.28 27 13.95 721 272 4.24 / 366.76 2 2
7 13 70.76 27 14.29 378 146 4.39 / 366.90 2 2
8 8 0.40 160 14.28 269 615 5.00 / 367.52 2 2
Average= 4.43 (KJ/cycle)

Cycle 81 GMT 11/12/2018 9:22:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 21 14.48 426 130 0.13 / 357.65 2 2
2 12 2002.80 40 10.83 3055 1323 1.45 / 358.97 2 2
3 7 1998.48 24 11.69 3148 883 2.34 / 359.86 2 2
4 13 1715.76 27 12.71 2727 936 3.27 / 360.79 2 2
5 13 1096.16 27 13.22 1888 674 3.95 / 361.47 2 2
6 13 288.84 27 13.95 738 278 4.22 / 361.75 2 2
7 13 77.20 27 14.28 395 152 4.38 / 361.90 2 2
8 8 0.48 160 14.27 271 619 4.99 / 362.52 2 2
Average= 4.42 (KJ/cycle)

Cycle 80 GMT 1/12/2018 9:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 21 14.48 414 126 0.13 / 352.71 2 2
2 7 2002.08 48 10.77 3096 1601 1.73 / 354.31 2 2
3 13 1746.52 42 12.40 2753 1434 3.16 / 355.74 2 2
4 13 843.76 42 13.27 1546 862 4.02 / 356.60 2 2
5 13 91.76 42 14.22 438 262 4.28 / 356.86 2 2
6 8 0.76 160 14.25 289 659 4.94 / 357.52 2 2
Average= 4.41 (KJ/cycle)

Cycle 79 GMT 21/11/2018 9:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 21 14.50 415 126 0.13 / 347.76 2 2
2 7 2005.32 48 10.71 3104 1596 1.72 / 349.36 2 2
3 13 1887.24 42 12.24 2956 1520 3.24 / 350.88 2 2
4 13 817.64 42 13.30 1492 833 4.08 / 351.71 2 2
5 13 83.04 42 14.23 414 247 4.32 / 351.96 2 2
6 8 0.08 160 14.26 272 621 4.94 / 352.58 2 2
Average= 4.41 (KJ/cycle)

Cycle 78 GMT 11/11/2018 9:18:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 22 14.50 419 134 0.13 / 343.00 2 2
2 7 2003.36 48 10.80 3129 1622 1.76 / 344.62 2 2
3 13 1748.16 42 12.43 2770 1446 3.20 / 346.06 2 2
4 13 680.88 42 13.44 1299 733 3.94 / 346.80 2 2
5 13 55.04 42 14.29 362 217 4.15 / 347.02 2 2
6 8 0.20 160 14.27 272 621 4.77 / 347.64 2 2
Average= 4.40 (KJ/cycle)

Cycle 77 GMT 1/11/2018 9: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 22 14.51 409 131 0.13 / 338.02 2 2
2 7 2002.08 48 10.87 3106 1621 1.75 / 339.64 2 2
3 13 1879.16 42 12.27 2955 1523 3.27 / 341.16 2 2
4 13 779.40 42 13.34 1444 809 4.08 / 341.97 2 2
5 13 69.16 42 14.24 410 245 4.33 / 342.22 2 2
6 8 0.40 160 14.25 283 645 4.97 / 342.86 2 2
Average= 4.40 (KJ/cycle)

Cycle 76 GMT 22/10/2018 9:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 21 14.49 414 126 0.13 / 333.06 2 2
2 3 1021.24 1 11.70 1861 22 0.15 / 333.08 2 2
3 3 1021.52 1 12.60 1837 23 0.17 / 333.11 2 2
4 7 2004.52 48 10.97 3122 1644 1.81 / 334.75 2 2
5 13 1885.52 42 12.28 2965 1529 3.34 / 336.28 2 2
6 13 681.68 42 13.45 1308 739 4.08 / 337.02 2 2
7 13 93.68 42 14.21 421 251 4.33 / 337.27 2 2
8 8 0.64 160 14.25 272 620 4.95 / 337.89 2 2
Average= 4.39 (KJ/cycle)

Cycle 75 GMT 12/10/2018 9:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 21 14.53 403 123 0.12 / 328.02 2 2
2 7 2003.24 48 11.01 3119 1648 1.77 / 329.67 2 2
3 13 1742.28 42 12.48 2754 1444 3.21 / 331.11 2 2
4 13 967.76 42 13.22 1684 935 4.15 / 332.05 2 2
5 13 116.68 42 14.18 457 272 4.42 / 332.32 2 2
6 8 0.24 160 14.26 269 614 5.04 / 332.93 2 2
Average= 4.38 (KJ/cycle)

Cycle 74 GMT 2/10/2018 9:38:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 21 14.52 420 128 0.13 / 323.05 2 2
2 7 2004.12 48 11.06 3117 1655 1.78 / 324.71 2 2
3 13 1884.00 42 12.31 2954 1527 3.31 / 326.24 2 2
4 13 786.20 42 13.37 1451 815 4.12 / 327.05 2 2
5 13 78.20 42 14.27 397 238 4.36 / 327.29 2 2
6 8 0.00 160 14.28 267 610 4.97 / 327.90 2 2
Average= 4.37 (KJ/cycle)

Cycle 73 GMT 22/ 9/2018 9:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 21 14.55 407 124 0.12 / 318.06 2 2
2 7 2007.44 48 11.06 3136 1665 1.79 / 319.72 2 2
3 13 1888.80 42 12.35 2934 1522 3.31 / 321.24 2 2
4 13 794.24 42 13.39 1460 821 4.13 / 322.07 2 2
5 13 79.04 42 14.28 399 239 4.37 / 322.30 2 2
6 8 0.08 160 14.29 272 622 4.99 / 322.93 2 2
Average= 4.36 (KJ/cycle)

Cycle 72 GMT 12/ 9/2018 9:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 22 14.54 413 132 0.13 / 313.25 2 2
2 7 2002.84 48 11.13 3142 1679 1.81 / 314.92 2 2
3 13 1736.36 42 12.53 2751 1448 3.26 / 316.37 2 2
4 13 660.28 42 13.52 1268 720 3.98 / 317.09 2 2
5 13 86.68 42 14.28 396 238 4.22 / 317.33 2 2
6 8 -0.08 160 14.30 264 604 4.82 / 317.93 2 2
Average= 4.36 (KJ/cycle)

Cycle 71 GMT 2/ 9/2018 9:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 22 14.53 400 128 0.13 / 308.33 2 2
2 3 959.68 -1 15.31 0 0 0.00 / 308.33 2 2
3 3 1044.96 1 13.30 1860 25 0.15 / 308.35 2 2
4 7 2006.64 48 11.33 3131 1703 1.86 / 310.05 2 2
5 13 1753.40 42 12.55 2776 1463 3.32 / 311.52 2 2
6 13 689.16 42 13.51 1307 742 4.06 / 312.26 2 2
7 13 91.28 42 14.26 406 243 4.30 / 312.50 2 2
8 8 -0.08 160 14.28 268 612 4.92 / 313.11 2 2
Average= 4.35 (KJ/cycle)

Cycle 70 GMT 23/ 8/2018 10: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 21 14.58 400 122 0.12 / 303.15 2 2
2 3 1020.24 1 12.66 1854 23 0.15 / 303.18 2 2
3 7 2006.60 49 11.48 3132 1762 1.91 / 304.94 2 2
4 13 1876.56 42 12.41 2938 1531 3.44 / 306.47 2 2
5 13 894.60 42 13.35 1588 890 4.33 / 307.36 2 2
6 13 95.28 42 14.27 408 245 4.57 / 307.61 2 2
7 8 -0.04 160 14.31 258 591 5.16 / 308.20 2 2
Average= 4.34 (KJ/cycle)

Cycle 69 GMT 13/ 8/2018 10:12: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 21 14.57 398 122 0.12 / 298.28 2 2
2 7 2002.52 48 11.46 3122 1717 1.84 / 300.00 2 2
3 13 1739.36 42 12.60 2754 1457 3.30 / 301.46 2 2
4 13 694.32 42 13.54 1312 746 4.04 / 302.20 2 2
5 13 87.92 42 14.29 397 238 4.28 / 302.44 2 2
6 8 0.24 160 14.31 258 591 4.87 / 303.03 2 2
Average= 4.33 (KJ/cycle)

Cycle 68 GMT 3/ 8/2018 10: 7: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 21 14.57 399 122 0.12 / 293.25 2 2
2 7 2002.88 48 11.59 3132 1742 1.86 / 294.99 2 2
3 13 1875.16 42 12.47 2923 1531 3.40 / 296.52 2 2
4 13 796.40 42 13.45 1463 826 4.22 / 297.35 2 2
5 13 76.44 42 14.33 375 226 4.45 / 297.57 2 2
6 8 -0.24 160 14.33 257 589 5.04 / 298.16 2 2
Average= 4.32 (KJ/cycle)

Cycle 67 GMT 24/ 7/2018 10: 7: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 21 14.59 407 125 0.12 / 288.29 2 2
2 3 1020.68 1 12.80 1882 24 0.15 / 288.31 2 2
3 7 2008.68 48 11.78 3135 1773 1.92 / 290.09 2 2
4 13 1888.00 42 12.50 2957 1552 3.47 / 291.64 2 2
5 13 609.12 42 13.62 1195 684 4.16 / 292.32 2 2
6 13 68.00 42 14.35 359 216 4.37 / 292.54 2 2
7 8 0.08 160 14.34 255 585 4.96 / 293.12 2 2
Average= 4.31 (KJ/cycle)

Cycle 66 GMT 14/ 7/2018 10:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 21 14.59 394 121 0.12 / 283.42 2 2
2 7 2003.48 48 11.83 3127 1776 1.90 / 285.20 2 2
3 13 1731.88 42 12.70 2735 1459 3.36 / 286.65 2 2
4 13 638.88 42 13.62 1236 707 4.06 / 287.36 2 2
5 13 73.24 42 14.34 366 220 4.28 / 287.58 2 2
6 8 0.12 160 14.34 254 583 4.87 / 288.17 2 2
Average= 4.30 (KJ/cycle)

Cycle 65 GMT 4/ 7/2018 10:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 21 14.59 413 127 0.13 / 278.51 2 2
2 3 1023.24 1 13.27 1842 24 0.15 / 278.54 2 2
3 7 2004.32 48 11.95 3128 1794 1.95 / 280.33 2 2
4 13 1620.56 42 12.83 2586 1393 3.34 / 281.73 2 2
5 13 688.16 42 13.60 1305 745 4.08 / 282.47 2 2
6 13 81.84 42 14.32 385 232 4.32 / 282.70 2 2
7 8 0.36 160 14.29 261 597 4.91 / 283.30 2 2
Average= 4.29 (KJ/cycle)

Cycle 64 GMT 24/ 6/2018 10:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 21 14.60 401 123 0.12 / 273.66 2 2
2 7 2002.76 49 11.97 3128 1835 1.96 / 275.50 2 2
3 13 1736.64 42 12.76 2738 1467 3.42 / 276.97 2 2
4 13 526.88 42 13.75 1081 624 4.05 / 277.59 2 2
5 13 48.72 42 14.38 331 200 4.25 / 277.79 2 2
6 8 0.32 160 14.30 261 597 4.85 / 278.39 2 2
Average= 4.28 (KJ/cycle)

Cycle 63 GMT 14/ 6/2018 11: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 20 14.61 404 118 0.12 / 268.53 2 2
2 7 2004.20 48 12.11 3131 1820 1.94 / 270.35 2 2
3 13 1876.92 42 12.62 2941 1559 3.50 / 271.91 2 2
4 13 737.12 42 13.56 1376 784 4.28 / 272.70 2 2
5 13 97.28 42 14.29 413 248 4.53 / 272.95 2 2
6 8 0.20 160 14.32 260 596 5.12 / 273.54 2 2
Average= 4.27 (KJ/cycle)

Cycle 62 GMT 4/ 6/2018 11:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 21 14.60 404 124 0.12 / 263.44 2 2
2 7 2004.36 48 12.14 3134 1826 1.95 / 265.26 2 2
3 13 1875.88 42 12.65 2927 1555 3.51 / 266.82 2 2
4 13 762.28 42 13.55 1408 801 4.31 / 267.62 2 2
5 13 62.24 42 14.38 350 211 4.52 / 267.83 2 2
6 8 0.32 160 14.35 255 585 5.10 / 268.42 2 2
Average= 4.26 (KJ/cycle)

Cycle 61 GMT 25/ 5/2018 11:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 21 14.63 397 122 0.12 / 258.42 2 2
2 7 2003.32 48 12.23 3144 1846 1.97 / 260.26 2 2
3 13 1873.20 42 12.67 2928 1558 3.53 / 261.82 2 2
4 13 608.36 42 13.69 1192 685 4.21 / 262.50 2 2
5 13 68.24 42 14.35 364 219 4.43 / 262.72 2 2
6 8 -0.12 160 14.33 257 589 5.02 / 263.31 2 2
Average= 4.25 (KJ/cycle)

Cycle 60 GMT 15/ 5/2018 11:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 22 14.62 396 127 0.13 / 253.59 2 2
2 3 951.52 -1 15.28 0 0 0.00 / 253.59 2 2
3 3 1021.80 1 12.77 1845 24 0.15 / 253.62 2 2
4 7 2002.40 49 12.34 3109 1880 2.03 / 255.50 2 2
5 13 1590.56 42 12.97 2526 1376 3.41 / 256.87 2 2
6 13 528.48 42 13.76 1086 628 4.03 / 257.50 2 2
7 13 46.16 42 14.38 329 199 4.23 / 257.70 2 2
8 8 0.36 160 14.31 259 593 4.83 / 258.29 2 2
Average= 4.23 (KJ/cycle)

Cycle 59 GMT 5/ 5/2018 11:33:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 21 14.62 416 128 0.13 / 248.68 2 2
2 3 1030.16 1 13.68 1852 25 0.15 / 248.70 2 2
3 7 2002.88 49 12.42 3115 1896 2.05 / 250.60 2 2
4 13 1596.52 42 12.97 2540 1384 3.43 / 251.98 2 2
5 13 635.48 42 13.67 1230 706 4.14 / 252.69 2 2
6 13 26.28 42 14.41 299 181 4.32 / 252.87 2 2
7 8 -0.04 160 14.30 262 599 4.92 / 253.47 2 2
Average= 4.22 (KJ/cycle)

Cycle 58 GMT 25/ 4/2018 11:28: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 21 14.63 400 123 0.12 / 244.07 2 2
2 7 2003.88 48 12.48 3118 1868 1.99 / 245.94 2 2
3 13 1598.16 42 13.00 2536 1385 3.38 / 247.32 2 2
4 13 519.20 42 13.78 1073 621 4.00 / 247.95 2 2
5 8 -0.04 160 14.33 263 603 4.60 / 248.55 2 2
Average= 4.21 (KJ/cycle)

Cycle 57 GMT 15/ 4/2018 11:10: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 21 14.65 394 121 0.12 / 239.53 2 2
2 7 2003.68 42 12.65 3119 1657 1.78 / 241.19 2 2
3 13 1874.60 31 12.93 2951 1183 2.96 / 242.37 2 2
4 13 978.20 31 13.53 1710 717 3.68 / 243.09 2 2
5 13 225.28 31 14.17 619 272 3.95 / 243.36 2 2
6 8 0.40 160 14.36 257 590 4.54 / 243.95 2 2
Average= 4.21 (KJ/cycle)

Cycle 56 GMT 5/ 4/2018 11: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 21 14.64 398 122 0.12 / 235.04 2 2
2 7 2000.84 42 12.71 3116 1663 1.79 / 236.70 2 2
3 13 1741.28 31 13.09 2756 1118 2.90 / 237.82 2 2
4 13 997.72 31 13.54 1731 727 3.63 / 238.55 2 2
5 13 237.76 31 14.17 637 280 3.91 / 238.83 2 2
6 8 -0.12 160 14.42 252 581 4.49 / 239.41 2 2
Average= 4.20 (KJ/cycle)

Cycle 55 GMT 26/ 3/2018 10:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 21 14.63 400 123 0.12 / 230.42 2 2
2 7 2007.96 43 12.76 3138 1722 1.84 / 232.14 2 2
3 13 1882.96 31 12.97 2946 1184 3.03 / 233.33 2 2
4 13 985.48 31 13.55 1718 722 3.75 / 234.05 2 2
5 13 221.56 31 14.18 618 272 4.02 / 234.32 2 2
6 8 0.00 160 14.40 259 597 4.62 / 234.92 2 2
Average= 4.19 (KJ/cycle)

Cycle 54 GMT 16/ 3/2018 10:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 21 14.65 394 121 0.12 / 225.96 2 2
2 7 1964.60 43 12.82 3063 1689 1.81 / 227.65 2 2
3 13 1703.04 31 13.11 2724 1107 2.92 / 228.75 2 2
4 13 936.80 31 13.58 1652 695 3.61 / 229.45 2 2
5 13 184.88 31 14.22 563 248 3.86 / 229.70 2 2
6 8 0.08 160 14.37 261 600 4.46 / 230.30 2 2
Average= 4.19 (KJ/cycle)

Cycle 53 GMT 6/ 3/2018 9:11: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 20 14.66 408 120 0.12 / 221.43 2 2
2 7 2004.76 42 12.85 3148 1699 1.82 / 223.13 2 2
3 13 1885.68 31 12.99 2964 1194 3.01 / 224.32 2 2
4 13 829.92 31 13.65 1511 639 3.65 / 224.96 2 2
5 13 219.44 31 14.18 621 273 3.92 / 225.23 2 2
6 8 0.48 160 14.36 262 602 4.53 / 225.84 2 2
Average= 4.18 (KJ/cycle)

Cycle 52 GMT 24/ 2/2018 8:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 21 14.67 409 126 0.13 / 216.95 2 2
2 7 2003.92 43 12.85 3112 1720 1.85 / 218.67 2 2
3 13 1730.88 31 13.15 2739 1117 2.96 / 219.79 2 2
4 13 832.56 31 13.66 1518 643 3.60 / 220.43 2 2
5 13 234.76 31 14.17 646 284 3.89 / 220.71 2 2
6 8 0.08 160 14.38 259 596 4.48 / 221.31 2 2
Average= 4.18 (KJ/cycle)

Cycle 51 GMT 14/ 2/2018 8:26: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 21 14.68 396 122 0.12 / 212.51 2 2
2 7 1978.84 42 12.89 3075 1665 1.79 / 214.17 2 2
3 13 1849.72 31 13.03 2917 1178 2.97 / 215.35 2 2
4 13 798.52 31 13.69 1468 623 3.59 / 215.98 2 2
5 13 200.80 31 14.25 581 257 3.84 / 216.23 2 2
6 8 0.24 160 14.44 257 594 4.44 / 216.83 2 2
Average= 4.17 (KJ/cycle)

Cycle 50 GMT 4/ 2/2018 7:12: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 21 14.68 402 124 0.12 / 208.70 2 2
2 7 1491.16 42 13.12 2396 1320 1.44 / 210.02 2 2
3 13 1395.80 31 13.29 2262 932 2.38 / 210.95 2 2
4 13 835.40 31 13.67 1515 642 3.02 / 211.59 2 2
5 13 123.08 31 14.38 453 202 3.22 / 211.80 2 2
6 8 -0.12 160 14.45 256 592 3.81 / 212.39 2 2
Average= 4.16 (KJ/cycle)

Cycle 49 GMT 25/ 1/2018 6:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 20 14.70 408 120 0.12 / 204.60 2 2
2 7 1756.04 43 13.01 2766 1547 1.67 / 206.15 2 2
3 13 1493.96 31 13.29 2416 995 2.66 / 207.15 2 2
4 13 763.40 31 13.75 1415 603 3.27 / 207.75 2 2
5 13 154.40 31 14.34 506 225 3.49 / 207.97 2 2
6 8 -0.20 160 14.44 260 601 4.09 / 208.58 2 2
Average= 4.17 (KJ/cycle)

Cycle 48 GMT 15/ 1/2018 6: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 21 14.72 395 122 0.12 / 200.25 2 2
2 7 2001.04 43 12.90 3113 1727 1.85 / 201.98 2 2
3 13 1591.44 31 13.27 2549 1049 2.90 / 203.03 2 2
4 13 847.88 31 13.71 1540 655 3.55 / 203.68 2 2
5 13 134.28 31 14.39 469 209 3.76 / 203.89 2 2
6 8 0.56 160 14.47 255 590 4.35 / 204.48 2 2
Average= 4.17 (KJ/cycle)

Cycle 47 GMT 5/ 1/2018 5:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 21 14.73 400 124 0.12 / 195.89 2 2
2 7 2005.24 43 12.93 3125 1737 1.86 / 197.62 2 2
3 13 1592.00 31 13.29 2537 1045 2.91 / 198.67 2 2
4 13 849.64 31 13.72 1538 654 3.56 / 199.32 2 2
5 13 141.00 31 14.39 479 214 3.77 / 199.54 2 2
6 8 0.72 160 14.47 257 595 4.37 / 200.13 2 2
Average= 4.17 (KJ/cycle)

Cycle 46 GMT 26/12/2017 5:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 21 14.73 405 125 0.13 / 191.32 2 2
2 7 2004.60 43 12.94 3098 1724 1.85 / 193.04 2 2
3 13 1876.48 31 13.09 2945 1195 3.04 / 194.23 2 2
4 13 923.44 31 13.68 1634 693 3.74 / 194.93 2 2
5 13 172.28 31 14.35 531 236 3.97 / 195.16 2 2
6 8 0.12 160 14.47 259 600 4.57 / 195.76 2 2
Average= 4.17 (KJ/cycle)

Cycle 45 GMT 16/12/2017 5:58: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 21 14.75 400 124 0.12 / 186.69 2 2
2 7 2002.48 42 12.98 3093 1686 1.81 / 188.38 2 2
3 13 1872.84 31 13.13 2916 1187 3.00 / 189.56 2 2
4 13 1098.60 31 13.58 1874 789 3.79 / 190.35 2 2
5 13 179.68 31 14.34 547 243 4.03 / 190.60 2 2
6 8 0.44 160 14.48 256 593 4.62 / 191.19 2 2
Average= 4.16 (KJ/cycle)

Cycle 44 GMT 6/12/2017 5:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 21 14.77 400 124 0.12 / 182.34 2 2
2 7 2003.04 42 12.97 3114 1696 1.82 / 184.04 2 2
3 13 1601.04 31 13.32 2563 1058 2.88 / 185.09 2 2
4 13 869.56 31 13.74 1557 663 3.54 / 185.76 2 2
5 13 148.00 31 14.42 490 219 3.76 / 185.98 2 2
6 8 0.36 160 14.49 255 591 4.35 / 186.57 2 2
Average= 4.15 (KJ/cycle)

Cycle 43 GMT 26/11/2017 5:29: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 21 14.77 398 123 0.12 / 177.86 2 2
2 7 2006.60 43 12.96 3135 1747 1.87 / 179.61 2 2
3 13 1606.68 31 13.32 2576 1064 2.93 / 180.67 2 2
4 13 743.52 31 13.84 1389 596 3.53 / 181.27 2 2
5 13 148.60 31 14.42 492 220 3.75 / 181.49 2 2
6 13 38.44 31 14.60 311 141 3.89 / 181.63 2 2
7 8 0.12 160 14.48 254 588 4.48 / 182.22 2 2
Average= 4.14 (KJ/cycle)

Cycle 42 GMT 16/11/2017 4:31:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 21 14.78 398 124 0.12 / 173.27 2 2
2 7 2007.56 42 13.00 3123 1705 1.83 / 174.98 2 2
3 13 1892.36 31 13.14 2957 1205 3.03 / 176.18 2 2
4 13 955.24 31 13.70 1680 713 3.75 / 176.89 2 2
5 13 191.80 31 14.36 566 252 4.00 / 177.15 2 2
6 8 0.24 160 14.53 254 590 4.59 / 177.74 2 2
Average= 4.13 (KJ/cycle)

Cycle 41 GMT 6/11/2017 4:31:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 21 14.77 398 123 0.12 / 168.87 2 2
2 7 2002.48 42 12.99 3116 1700 1.82 / 170.57 2 2
3 13 1744.56 31 13.26 2755 1132 2.96 / 171.70 2 2
4 13 846.48 31 13.78 1532 654 3.61 / 172.36 2 2
5 13 120.56 31 14.46 450 202 3.81 / 172.56 2 2
6 8 0.40 160 14.51 254 590 4.40 / 173.15 2 2
Average= 4.12 (KJ/cycle)

Cycle 40 GMT 27/10/2017 4: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 21 14.78 400 124 0.12 / 164.16 2 2
2 7 2000.80 43 12.99 3114 1739 1.86 / 165.90 2 2
3 13 1726.60 31 13.29 2729 1124 2.99 / 167.02 2 2
4 13 977.16 31 13.70 1717 729 3.72 / 167.75 2 2
5 13 190.24 31 14.37 568 253 3.97 / 168.00 2 2
6 13 36.08 31 14.59 314 142 4.11 / 168.14 2 2
7 8 0.28 160 14.46 260 602 4.71 / 168.75 2 2
Average= 4.12 (KJ/cycle)

Cycle 39 GMT 17/10/2017 3:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 21 14.78 394 122 0.12 / 159.64 2 2
2 7 2001.80 42 13.01 3102 1695 1.82 / 161.33 2 2
3 13 1728.56 31 13.28 2729 1123 2.94 / 162.46 2 2
4 13 975.08 31 13.71 1715 729 3.67 / 163.18 2 2
5 13 188.40 31 14.38 565 252 3.92 / 163.44 2 2
6 8 0.24 160 14.53 256 595 4.52 / 164.03 2 2
Average= 4.10 (KJ/cycle)

Cycle 38 GMT 7/10/2017 2:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 21 14.81 398 124 0.12 / 155.04 2 2
2 7 2003.20 42 13.04 3121 1709 1.83 / 156.75 2 2
3 13 1751.40 31 13.27 2752 1132 2.97 / 157.88 2 2
4 13 885.64 31 13.78 1591 680 3.64 / 158.56 2 2
5 13 147.24 31 14.47 491 220 3.87 / 158.78 2 2
6 13 32.08 31 14.63 305 138 4.00 / 158.92 2 2
7 8 -0.04 160 14.49 257 596 4.60 / 159.52 2 2
Average= 4.09 (KJ/cycle)

Cycle 37 GMT 27/ 9/2017 1:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 21 14.79 393 122 0.12 / 150.26 2 2
2 7 2004.12 43 13.02 3129 1752 1.87 / 152.02 2 2
3 13 1875.12 31 13.18 2932 1198 3.07 / 153.21 2 2
4 13 951.20 31 13.74 1682 716 3.79 / 153.93 2 2
5 13 192.08 31 14.41 563 251 4.04 / 154.18 2 2
6 13 42.04 31 14.63 316 143 4.18 / 154.32 2 2
7 8 -0.12 160 14.50 255 592 4.77 / 154.92 2 2
Average= 4.08 (KJ/cycle)

Cycle 36 GMT 17/ 9/2017 1:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 21 14.79 389 121 0.12 / 145.78 2 2
2 7 2002.72 43 13.01 3115 1743 1.86 / 147.52 2 2
3 13 1738.92 31 13.27 2758 1135 3.00 / 148.66 2 2
4 13 807.56 31 13.82 1482 635 3.63 / 149.29 2 2
5 13 188.12 31 14.40 564 252 3.88 / 149.55 2 2
6 8 -0.24 160 14.54 256 596 4.48 / 150.14 2 2
Average= 4.06 (KJ/cycle)

Cycle 35 GMT 7/ 9/2017 1:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 21 14.78 390 121 0.12 / 141.23 2 2
2 7 2003.08 42 13.03 3120 1707 1.83 / 142.93 2 2
3 13 1872.92 31 13.16 2922 1192 3.02 / 144.12 2 2
4 13 852.52 31 13.79 1540 658 3.68 / 144.78 2 2
5 13 235.80 31 14.34 641 285 3.96 / 145.07 2 2
6 8 0.16 160 14.53 255 593 4.56 / 145.66 2 2
Average= 4.05 (KJ/cycle)

Cycle 34 GMT 28/ 8/2017 1:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 21 14.81 396 123 0.12 / 136.71 2 2
2 7 2003.08 43 13.03 3103 1739 1.86 / 138.45 2 2
3 13 1874.64 31 13.16 2930 1195 3.06 / 139.64 2 2
4 13 794.76 31 13.84 1460 626 3.68 / 140.27 2 2
5 13 183.12 31 14.42 554 248 3.93 / 140.52 2 2
6 8 0.08 160 14.54 253 589 4.52 / 141.10 2 2
Average= 4.03 (KJ/cycle)

Cycle 33 GMT 18/ 8/2017 1:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 21 14.81 394 123 0.12 / 132.36 2 2
2 7 2002.16 42 13.04 3118 1708 1.83 / 134.06 2 2
3 13 1737.28 31 13.27 2739 1127 2.96 / 135.19 2 2
4 13 722.96 31 13.89 1363 587 3.54 / 135.78 2 2
5 13 155.08 31 14.48 502 225 3.77 / 136.00 2 2
6 8 0.12 160 14.57 250 583 4.35 / 136.58 2 2
Average= 4.02 (KJ/cycle)

Cycle 32 GMT 8/ 8/2017 0:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 21 14.80 398 124 0.12 / 127.76 2 2
2 7 2004.60 43 13.03 3129 1753 1.88 / 129.52 2 2
3 13 1880.32 31 13.16 2939 1199 3.08 / 130.71 2 2
4 13 809.64 31 13.84 1482 636 3.71 / 131.35 2 2
5 13 135.04 31 14.53 460 207 3.92 / 131.56 2 2
6 13 31.84 31 14.67 295 134 4.05 / 131.69 2 2
7 8 0.32 150 14.55 248 541 4.59 / 132.23 2 2
Average= 4.01 (KJ/cycle)

Cycle 31 GMT 28/ 7/2017 23:29: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 21 14.82 393 122 0.12 / 123.09 2 2
2 3 1024.04 1 14.32 1831 26 0.15 / 123.12 2 2
3 7 2004.40 42 13.08 3104 1705 1.85 / 124.83 2 2
4 13 1878.28 31 13.19 2933 1199 3.05 / 126.02 2 2
5 13 823.88 31 13.84 1503 645 3.70 / 126.67 2 2
6 13 219.76 31 14.40 607 271 3.97 / 126.94 2 2
7 13 47.84 31 14.65 321 146 4.11 / 127.09 2 2
8 8 0.44 150 14.54 253 552 4.67 / 127.64 2 2
Average= 3.99 (KJ/cycle)

Cycle 30 GMT 18/ 7/2017 22:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 21 14.83 396 123 0.12 / 118.84 2 2
2 7 2005.16 42 13.07 3132 1719 1.84 / 120.55 2 2
3 13 1479.64 31 13.43 2391 995 2.84 / 121.55 2 2
4 13 791.44 31 13.86 1458 626 3.46 / 122.18 2 2
5 13 183.24 31 14.45 550 246 3.71 / 122.42 2 2
6 8 0.40 150 14.59 251 549 4.26 / 122.97 2 2
Average= 3.97 (KJ/cycle)

Cycle 29 GMT 8/ 7/2017 21:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 20 14.83 392 116 0.12 / 114.55 2 2
2 7 2007.04 43 13.06 3107 1745 1.86 / 116.30 2 2
3 13 1485.60 31 13.43 2408 1003 2.86 / 117.30 2 2
4 13 779.12 31 13.88 1438 619 3.48 / 117.92 2 2
5 13 173.92 31 14.47 534 240 3.72 / 118.16 2 2
6 8 -0.20 150 14.57 254 555 4.28 / 118.71 2 2
Average= 3.96 (KJ/cycle)

Cycle 28 GMT 28/ 6/2017 20:33:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 20 14.82 388 115 0.12 / 110.23 2 2
2 7 2004.12 42 13.06 3104 1703 1.82 / 111.93 2 2
3 13 1622.64 31 13.35 2594 1074 2.89 / 113.00 2 2
4 13 868.00 31 13.82 1559 668 3.56 / 113.67 2 2
5 13 152.32 31 14.52 490 221 3.78 / 113.89 2 2
6 8 0.04 150 14.59 248 543 4.32 / 114.43 2 2
Average= 3.95 (KJ/cycle)

Cycle 27 GMT 18/ 6/2017 19:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 21 14.81 394 123 0.12 / 105.82 2 2
2 7 2001.76 43 13.06 3120 1752 1.87 / 107.58 2 2
3 13 1606.96 31 13.37 2559 1061 2.94 / 108.64 2 2
4 13 835.12 31 13.85 1512 649 3.58 / 109.29 2 2
5 13 225.32 31 14.40 617 275 3.86 / 109.56 2 2
6 8 0.56 150 14.60 252 552 4.41 / 110.11 2 2
Average= 3.93 (KJ/cycle)

Cycle 26 GMT 8/ 6/2017 19:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 21 14.83 396 123 0.12 / 101.28 2 2
2 7 2007.00 43 13.08 3122 1756 1.88 / 103.03 2 2
3 13 1880.68 31 13.21 2943 1205 3.08 / 104.24 2 2
4 13 821.84 31 13.87 1499 645 3.73 / 104.88 2 2
5 13 197.28 31 14.43 579 259 3.99 / 105.14 2 2
6 8 0.28 150 14.58 256 560 4.55 / 105.70 2 2
Average= 3.91 (KJ/cycle)

Cycle 25 GMT 29/ 5/2017 18:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 22 14.84 394 129 0.13 / 96.66 2 2
2 3 942.72 -1 15.44 0 0 0.00 / 96.66 2 2
3 3 1023.60 1 14.37 1854 27 0.16 / 96.68 2 2
4 7 2003.32 42 13.14 3102 1712 1.87 / 98.40 2 2
5 13 1609.76 31 13.40 2564 1065 2.93 / 99.46 2 2
6 13 990.48 31 13.77 1737 741 3.67 / 100.20 2 2
7 13 190.84 31 14.46 563 252 3.93 / 100.45 2 2
8 13 40.32 31 14.70 314 143 4.07 / 100.60 2 2
9 8 -0.36 150 14.56 254 555 4.62 / 101.15 2 2
Average= 3.89 (KJ/cycle)

Cycle 24 GMT 19/ 5/2017 18:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 21 14.88 399 125 0.12 / 92.58 2 2
2 3 1039.80 1 14.53 1860 27 0.15 / 92.61 2 2
3 7 1999.12 43 13.13 3106 1754 1.91 / 94.36 2 2
4 13 1369.12 29 13.55 2252 885 2.79 / 95.24 2 2
5 13 689.44 29 14.00 1313 533 3.32 / 95.78 2 2
6 13 138.92 29 14.57 471 199 3.52 / 95.98 2 2
7 8 -0.16 150 14.62 252 553 4.07 / 96.53 2 2
Average= 3.86 (KJ/cycle)

Cycle 23 GMT 9/ 5/2017 16:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 20 14.86 400 119 0.12 / 88.42 2 2
2 7 2003.12 43 13.14 3128 1767 1.89 / 90.19 2 2
3 13 1486.88 29 13.51 2411 945 2.83 / 91.13 2 2
4 13 786.88 29 13.94 1452 587 3.42 / 91.72 2 2
5 13 115.08 29 14.61 433 183 3.60 / 91.90 2 2
6 8 0.08 150 14.62 251 550 4.15 / 92.45 2 2
Average= 3.85 (KJ/cycle)

Cycle 22 GMT 29/ 4/2017 15:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 21 14.87 397 124 0.12 / 84.21 2 2
2 7 2001.48 37 13.23 3105 1520 1.64 / 85.73 2 2
3 13 1632.44 29 13.43 2607 1015 2.66 / 86.75 2 2
4 13 818.16 29 13.92 1501 606 3.27 / 87.36 2 2
5 13 233.56 29 14.42 636 266 3.53 / 87.62 2 2
6 13 24.72 29 14.76 288 123 3.65 / 87.74 2 2
7 8 -0.20 150 14.58 255 558 4.21 / 88.30 2 2
Average= 3.84 (KJ/cycle)

Cycle 21 GMT 19/ 4/2017 14:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 21 14.87 397 124 0.12 / 79.90 2 2
2 7 2002.80 38 13.26 3111 1568 1.69 / 81.47 2 2
3 13 1760.56 29 13.38 2774 1076 2.77 / 82.55 2 2
4 13 803.72 29 13.93 1475 596 3.36 / 83.14 2 2
5 13 246.68 29 14.42 651 272 3.64 / 83.42 2 2
6 13 21.08 29 14.79 282 121 3.76 / 83.54 2 2
7 8 0.52 150 14.61 252 552 4.31 / 84.09 2 2
Average= 3.82 (KJ/cycle)

Cycle 20 GMT 9/ 4/2017 13:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 21 14.88 391 122 0.12 / 75.81 2 2
2 7 2002.52 37 13.26 3118 1530 1.65 / 77.34 2 2
3 13 1633.52 29 13.45 2602 1015 2.67 / 78.36 2 2
4 13 804.44 29 13.94 1478 597 3.26 / 78.96 2 2
5 13 237.96 29 14.44 641 268 3.53 / 79.22 2 2
6 8 0.08 150 14.65 253 556 4.09 / 79.78 2 2
Average= 3.80 (KJ/cycle)

Cycle 19 GMT 30/ 3/2017 12:42: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 21 14.88 398 124 0.12 / 71.68 2 2
2 7 2004.00 37 13.29 3116 1532 1.66 / 73.21 2 2
3 13 1629.88 29 13.45 2603 1015 2.67 / 74.23 2 2
4 13 927.00 29 13.87 1643 661 3.33 / 74.89 2 2
5 13 200.80 29 14.50 580 244 3.58 / 75.13 2 2
6 8 0.28 150 14.64 255 560 4.14 / 75.69 2 2
Average= 3.78 (KJ/cycle)

Cycle 18 GMT 20/ 3/2017 11:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 21 14.89 398 124 0.12 / 67.55 2 2
2 7 2007.24 37 13.29 3101 1525 1.65 / 69.08 2 2
3 13 1639.36 29 13.45 2617 1021 2.67 / 70.10 2 2
4 13 831.64 29 13.93 1511 610 3.28 / 70.71 2 2
5 13 266.72 29 14.42 685 286 3.57 / 71.00 2 2
6 8 0.36 150 14.65 255 560 4.13 / 71.56 2 2
Average= 3.77 (KJ/cycle)

Cycle 17 GMT 10/ 3/2017 10: 4: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 21 14.91 392 123 0.12 / 63.53 2 2
2 7 2002.52 37 13.30 3103 1527 1.65 / 65.06 2 2
3 13 1631.48 29 13.46 2598 1014 2.66 / 66.07 2 2
4 13 807.24 29 13.95 1483 600 3.26 / 66.67 2 2
5 13 135.76 29 14.63 468 199 3.46 / 66.87 2 2
6 8 -0.68 150 14.66 253 556 4.02 / 67.43 2 2
Average= 3.75 (KJ/cycle)

Cycle 16 GMT 28/ 2/2017 9:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 21 14.90 400 125 0.13 / 59.45 2 2
2 7 2004.16 37 13.31 3106 1530 1.65 / 60.98 2 2
3 13 1765.48 29 13.42 2787 1085 2.74 / 62.07 2 2
4 13 801.56 29 13.96 1469 595 3.33 / 62.66 2 2
5 13 145.68 29 14.64 478 203 3.54 / 62.86 2 2
6 8 0.56 150 14.68 248 546 4.08 / 63.41 2 2
Average= 3.73 (KJ/cycle)

Cycle 15 GMT 18/ 2/2017 7:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 22 14.89 392 128 0.13 / 55.46 2 2
2 3 951.12 -1 15.48 0 0 0.00 / 55.46 2 2
3 3 1024.20 1 14.58 1847 27 0.16 / 55.49 2 2
4 7 2002.28 37 13.32 3098 1527 1.68 / 57.01 2 2
5 13 1612.36 29 13.49 2576 1008 2.69 / 58.02 2 2
6 13 687.72 29 14.04 1312 534 3.22 / 58.56 2 2
7 13 156.72 29 14.60 505 214 3.44 / 58.77 2 2
8 8 -0.32 150 14.66 253 556 3.99 / 59.33 2 2
Average= 3.71 (KJ/cycle)

Cycle 14 GMT 8/ 2/2017 6:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 21 14.90 409 128 0.13 / 51.39 2 2
2 7 2000.36 37 13.33 3092 1525 1.65 / 52.91 2 2
3 13 1493.32 29 13.54 2405 944 2.60 / 53.86 2 2
4 13 937.28 29 13.87 1657 666 3.26 / 54.52 2 2
5 13 203.60 29 14.53 583 246 3.51 / 54.77 2 2
6 8 0.04 150 14.63 256 562 4.07 / 55.33 2 2
Average= 3.69 (KJ/cycle)

Cycle 13 GMT 29/ 1/2017 5:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 21 14.92 397 124 0.12 / 47.05 2 2
2 3 972.28 -1 15.49 0 0 0.00 / 47.05 2 2
3 3 1045.28 1 14.63 1862 27 0.15 / 47.08 2 2
4 7 2002.52 37 13.33 3107 1532 1.68 / 48.61 2 2
5 13 1762.32 29 13.42 2779 1082 2.77 / 49.69 2 2
6 13 907.72 29 13.89 1615 651 3.42 / 50.34 2 2
7 13 200.28 29 14.54 578 244 3.66 / 50.59 2 2
8 13 14.96 29 14.84 274 118 3.78 / 50.70 2 2
9 8 0.04 150 14.58 255 558 4.34 / 51.26 2 2
Average= 3.66 (KJ/cycle)

Cycle 12 GMT 19/ 1/2017 4:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 21 14.92 392 123 0.12 / 43.01 2 2
2 7 1981.76 37 13.35 3074 1518 1.64 / 44.53 2 2
3 13 1744.96 29 13.42 2754 1072 2.71 / 45.60 2 2
4 13 776.36 29 13.96 1442 584 3.30 / 46.18 2 2
5 13 125.56 29 14.68 446 190 3.49 / 46.37 2 2
6 8 -0.04 150 14.69 250 551 4.04 / 46.93 2 2
Average= 3.61 (KJ/cycle)

Cycle 11 GMT 9/ 1/2017 2:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 22 14.95 395 130 0.13 / 38.74 2 2
2 7 2004.72 38 13.33 3105 1573 1.70 / 40.31 2 2
3 13 1885.84 29 13.35 2940 1138 2.84 / 41.45 2 2
4 13 891.92 29 13.89 1601 645 3.49 / 42.10 2 2
5 13 189.68 29 14.58 558 236 3.72 / 42.33 2 2
6 8 0.16 150 14.70 252 556 4.28 / 42.89 2 2
Average= 3.57 (KJ/cycle)

Cycle 10 GMT 30/12/2016 1:14: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 21 14.95 392 123 0.12 / 35.33 2 2
2 7 1333.64 37 13.71 2193 1112 1.24 / 36.44 2 2
3 13 1245.12 29 13.68 2077 824 2.06 / 37.26 2 2
4 13 580.64 29 14.11 1165 477 2.54 / 37.74 2 2
5 13 102.84 29 14.72 410 175 2.71 / 37.92 2 2
6 8 0.08 190 14.63 250 695 3.41 / 38.61 2 2
Average= 3.51 (KJ/cycle)

Cycle 9 GMT 20/12/2016 0:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 22 14.95 389 128 0.13 / 31.71 2 2
2 3 939.48 -1 15.49 0 0 0.00 / 31.71 2 2
3 7 1312.68 46 13.56 2152 1342 1.47 / 33.05 2 2
4 13 1198.32 29 13.72 2008 799 2.27 / 33.85 2 2
5 13 621.36 29 14.08 1215 496 2.77 / 34.35 2 2
6 13 85.80 29 14.74 379 162 2.93 / 34.51 2 2
7 8 0.16 190 14.62 250 694 3.62 / 35.20 2 2
Average= 3.52 (KJ/cycle)

Cycle 8 GMT 10/12/2016 1: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 23 14.92 405 139 0.14 / 27.57 2 2
2 3 956.20 -1 15.50 0 0 0.00 / 27.57 2 2
3 3 1031.36 1 14.61 1825 27 0.17 / 27.59 2 2
4 7 1987.40 45 13.20 3066 1821 1.99 / 29.42 2 2
5 13 1352.12 29 13.59 2200 867 2.85 / 30.28 2 2
6 13 540.44 29 14.14 1098 450 3.30 / 30.73 2 2
7 13 68.64 29 14.76 357 153 3.46 / 30.89 2 2
8 8 0.12 190 14.60 251 696 4.15 / 31.58 2 2
Average= 3.51 (KJ/cycle)

Cycle 7 GMT 29/11/2016 23: 9: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 23 14.94 390 134 0.13 / 23.34 2 2
2 3 947.52 -1 15.50 0 0 0.00 / 23.34 2 2
3 3 1020.96 1 14.58 1821 27 0.16 / 23.37 2 2
4 7 1988.24 45 13.19 3063 1818 1.98 / 25.19 2 2
5 13 1469.56 29 13.52 2375 931 2.91 / 26.12 2 2
6 13 500.52 29 14.17 1045 429 3.34 / 26.55 2 2
7 13 103.20 29 14.67 419 178 3.52 / 26.73 2 2
8 8 0.12 190 14.57 254 703 4.22 / 27.43 2 2
Average= 3.43 (KJ/cycle)

Cycle 6 GMT 19/11/2016 21:26: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 22 14.94 404 133 0.13 / 19.16 2 2
2 3 1037.84 1 14.62 1851 27 0.16 / 19.19 2 2
3 7 1971.28 45 13.19 3046 1808 1.97 / 21.00 2 2
4 13 1450.04 26 13.54 2354 829 2.80 / 21.83 2 2
5 13 772.80 26 13.96 1430 519 3.32 / 22.35 2 2
6 13 114.92 26 14.68 437 167 3.48 / 22.51 2 2
7 8 0.12 190 14.60 251 696 4.18 / 23.21 2 2
Average= 3.32 (KJ/cycle)

Cycle 5 GMT 9/11/2016 19:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 24 14.91 381 136 0.14 / 15.07 2 2
2 3 869.08 -2 15.51 0 0 0.00 / 15.07 2 2
3 7 1957.76 45 13.16 3021 1789 1.93 / 16.85 2 2
4 13 1452.40 26 13.51 2350 825 2.75 / 17.68 2 2
5 13 748.40 26 13.96 1393 506 3.26 / 18.19 2 2
6 13 90.00 26 14.71 396 151 3.41 / 18.34 2 2
7 8 0.08 190 14.59 250 693 4.10 / 19.03 2 2
Average= 3.17 (KJ/cycle)

Cycle 4 GMT 30/10/2016 17:59: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 23 14.90 383 131 0.13 / 11.58 2 2
2 3 942.92 -1 15.50 0 0 0.00 / 11.58 2 2
3 7 1511.16 45 13.41 2411 1455 1.59 / 13.03 2 2
4 13 1166.08 22 13.74 1961 593 2.18 / 13.62 2 2
5 13 635.68 22 14.07 1234 382 2.56 / 14.01 2 2
6 13 123.60 22 14.66 450 145 2.71 / 14.15 2 2
7 13 29.16 22 14.80 294 96 2.80 / 14.25 2 2
8 8 0.08 190 14.55 247 683 3.48 / 14.93 2 2
Average= 2.99 (KJ/cycle)

Cycle 3 GMT 29/10/2016 18: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 24 14.85 380 135 0.14 / 8.12 2 2
2 3 927.40 -1 15.50 0 0 0.00 / 8.12 2 2
3 7 1505.52 45 13.34 2380 1429 1.56 / 9.55 2 2
4 13 1263.32 22 13.70 2088 629 2.19 / 10.18 2 2
5 13 585.80 22 14.08 1164 361 2.55 / 10.54 2 2
6 13 106.24 22 14.67 416 134 2.69 / 10.67 2 2
7 13 26.44 22 14.78 287 93 2.78 / 10.77 2 2
8 8 0.12 190 14.53 246 679 3.46 / 11.44 2 2
Average= 2.86 (KJ/cycle)

Cycle 2 GMT 28/10/2016 18:14: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 24 14.78 392 139 0.14 / 4.27 2 2
2 3 910.24 -2 15.49 0 0 0.00 / 4.27 2 2
3 3 1047.88 1 14.42 1849 27 0.17 / 4.29 2 2
4 7 1508.36 74 13.01 2363 2275 2.44 / 6.57 2 2
5 13 620.88 25 13.94 1209 421 2.86 / 6.99 2 2
6 13 97.60 25 14.60 403 147 3.01 / 7.14 2 2
7 8 0.12 240 14.47 244 847 3.86 / 7.98 2 4
Average= 2.66 (KJ/cycle)

Cycle 1 GMT 27/10/2016 18:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 24 14.84 362 129 0.13 / 1.44 2 2
2 3 907.52 -2 15.47 0 0 0.00 / 1.44 2 2
3 3 1050.24 1 14.13 1857 26 0.16 / 1.46 2 2
4 7 1021.72 74 13.18 1728 1685 1.84 / 3.15 2 2
5 13 79.80 25 14.52 372 135 1.98 / 3.28 2 2
6 8 0.20 240 14.40 244 843 2.82 / 4.13 2 9
Average= 2.06 (KJ/cycle)

Cycle 0 GMT 27/10/2016 7:14:58

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 24 14.57 391 137 0.14 / 0.14 2 2
2 7 124.48 74 14.39 398 424 0.56 / 0.56 2 2
3 8 0.08 240 14.63 213 748 1.31 / 1.31 2 3
Average= 1.31 (KJ/cycle)