SIO Argo Site:
Pump Diagnostics Page   



Serial= 8468 WMO= 5902508

Return

←PreviousNext→

Cycle 264 GMT 12/ 6/2023 23:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 29 11.11 416 134 0.13 / 1435.32 2 2
2 10 1034.16 7 8.96 1824 114 0.25 / 1435.43 2 2
3 10 1063.84 4 8.78 1862 65 0.31 / 1435.50 2 2
4 12 1125.28 200 6.07 1791 2174 2.49 / 1437.67 2 2
5 7 1121.44 24 6.08 1870 273 2.76 / 1437.94 2 2
6 13 1032.16 51 7.36 1767 663 3.42 / 1438.61 2 2
7 13 910.64 51 7.76 1612 638 4.06 / 1439.24 2 2
8 13 161.48 51 10.20 520 271 4.33 / 1439.51 2 2
9 8 -0.16 160 10.79 259 447 4.78 / 1439.96 2 4
Average= 5.43 (KJ/cycle)

Cycle 263 GMT 3/ 6/2023 5: 4: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 31 11.99 420 156 0.16 / 1429.96 2 2
2 3 1044.76 2 10.03 1844 37 0.19 / 1430.00 2 2
3 12 1149.80 200 5.53 1727 1910 2.10 / 1431.91 2 2
4 7 1154.60 24 6.79 1941 316 2.42 / 1432.22 2 2
5 13 1221.28 51 6.79 2024 701 3.12 / 1432.92 2 2
6 13 1143.20 51 7.29 1919 713 3.83 / 1433.64 2 2
7 13 1014.84 51 7.86 1744 699 4.53 / 1434.34 2 2
8 13 286.08 51 10.27 716 375 4.91 / 1434.71 2 2
9 8 -0.08 160 11.20 262 470 5.38 / 1435.18 2 3
Average= 5.44 (KJ/cycle)

Cycle 262 GMT 24/ 5/2023 10:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 28 12.66 434 154 0.15 / 1425.99 2 2
2 10 1005.12 4 11.23 1805 81 0.23 / 1426.07 2 2
3 12 1106.40 200 6.64 1881 2498 2.73 / 1428.57 2 2
4 7 1099.32 24 8.26 1895 376 3.11 / 1428.94 2 2
5 13 204.92 51 11.35 601 348 3.46 / 1429.29 2 2
6 8 -0.16 160 11.97 267 511 3.97 / 1429.80 2 4
Average= 5.44 (KJ/cycle)

Cycle 261 GMT 14/ 5/2023 16:22: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 28 13.23 431 160 0.16 / 1418.67 2 2
2 3 1047.64 2 11.31 1890 43 0.20 / 1418.72 2 2
3 3 1015.76 1 10.95 1823 20 0.22 / 1418.74 2 2
4 12 1120.68 3 10.95 1992 65 0.29 / 1418.80 2 2
5 12 1986.32 200 6.76 2955 3995 4.28 / 1422.80 2 2
6 7 1980.40 24 7.60 3198 583 4.87 / 1423.38 2 2
7 13 1401.96 51 9.21 2358 1108 5.97 / 1424.49 2 2
8 13 492.44 51 11.10 1051 595 6.57 / 1425.08 2 3
9 13 33.52 51 12.53 327 209 6.78 / 1425.29 2 3
10 8 -0.08 160 12.40 275 546 7.32 / 1425.84 2 4
Average= 5.44 (KJ/cycle)

Cycle 260 GMT 13/ 5/2023 13:39: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 28 13.70 434 166 0.17 / 1412.98 2 2
2 3 1021.76 1 10.98 1847 20 0.19 / 1413.00 2 2
3 12 1165.36 200 5.47 1581 1730 1.92 / 1414.73 2 2
4 7 1170.36 24 8.65 2013 418 2.33 / 1415.15 2 2
5 13 1255.96 51 7.73 2097 827 3.16 / 1415.98 2 2
6 13 1185.88 51 8.28 2015 851 4.01 / 1416.83 2 2
7 13 902.88 51 9.50 1637 793 4.80 / 1417.62 2 2
8 13 138.16 51 12.40 505 319 5.12 / 1417.94 2 3
9 8 -0.04 160 12.80 280 573 5.70 / 1418.51 2 8
Average= 5.43 (KJ/cycle)

Cycle 259 GMT 3/ 5/2023 18:56: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 28 13.90 453 176 0.18 / 1407.31 2 2
2 12 1141.76 200 5.46 1594 1741 1.92 / 1409.05 2 2
3 7 1146.44 24 8.66 1975 410 2.33 / 1409.46 2 2
4 13 1232.28 51 7.74 2065 815 3.14 / 1410.27 2 2
5 13 1178.40 51 8.38 2007 858 4.00 / 1411.13 2 2
6 13 790.68 51 10.31 1477 777 4.78 / 1411.91 2 2
7 13 85.32 51 13.32 424 288 5.06 / 1412.19 2 4
8 8 -0.04 160 13.46 288 620 5.69 / 1412.82 2 5
Average= 5.43 (KJ/cycle)

Cycle 258 GMT 24/ 4/2023 0: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 28 14.05 441 173 0.17 / 1403.06 2 2
2 12 1137.44 200 6.27 1905 2389 2.56 / 1405.45 2 2
3 7 1131.56 25 9.56 1966 470 3.03 / 1405.92 2 2
4 13 390.00 51 12.47 902 574 3.61 / 1406.49 2 3
5 8 -0.04 160 13.76 291 641 4.25 / 1407.13 2 10
Average= 5.43 (KJ/cycle)

Cycle 257 GMT 14/ 4/2023 6: 7: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 28 14.04 432 170 0.17 / 1395.73 2 2
2 12 1106.40 3 10.83 1964 64 0.23 / 1395.79 2 2
3 12 1985.24 200 6.90 3049 4208 4.44 / 1400.00 2 2
4 7 1979.04 24 8.88 3209 684 5.13 / 1400.68 2 2
5 13 1121.24 51 11.47 1991 1165 6.29 / 1401.85 2 2
6 13 157.44 51 13.64 549 382 6.67 / 1402.23 2 5
7 8 -0.24 160 13.96 292 652 7.32 / 1402.88 2 10
Average= 5.44 (KJ/cycle)

Cycle 256 GMT 13/ 4/2023 3: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 28 14.03 451 177 0.18 / 1390.09 2 2
2 12 1147.72 200 5.47 1649 1804 1.98 / 1391.89 2 2
3 7 1153.44 24 9.21 2000 442 2.42 / 1392.33 2 2
4 13 1253.56 51 8.81 2116 951 3.37 / 1393.28 2 2
5 13 1165.72 51 9.59 2002 979 4.35 / 1394.26 2 2
6 13 467.56 51 12.56 1015 650 5.00 / 1394.91 2 3
7 8 -0.04 160 14.01 289 648 5.65 / 1395.56 2 6
Average= 5.43 (KJ/cycle)

Cycle 255 GMT 3/ 4/2023 8:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 28 14.07 461 182 0.18 / 1384.24 2 2
2 12 1161.36 200 5.51 1795 1978 2.16 / 1386.22 2 2
3 7 1166.92 24 9.39 2018 455 2.61 / 1386.67 2 2
4 13 1244.48 51 9.06 2101 971 3.59 / 1387.64 2 2
5 13 1147.04 51 9.89 1978 998 4.58 / 1388.64 2 2
6 13 417.88 51 12.75 947 616 5.20 / 1389.26 2 4
7 8 -0.08 160 14.03 291 653 5.85 / 1389.91 2 7
Average= 5.43 (KJ/cycle)

Cycle 254 GMT 24/ 3/2023 13:43: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 28 14.14 438 173 0.17 / 1380.07 2 2
2 12 1105.84 200 6.54 1864 2438 2.61 / 1382.51 2 2
3 7 1098.84 24 10.05 1932 466 3.08 / 1382.97 2 2
4 13 193.56 51 13.51 613 422 3.50 / 1383.39 2 5
5 8 0.00 160 14.12 293 662 4.16 / 1384.06 2 9
Average= 5.43 (KJ/cycle)

Cycle 253 GMT 14/ 3/2023 19:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 28 14.01 453 178 0.18 / 1372.55 2 2
2 12 1093.92 3 10.83 1942 63 0.24 / 1372.62 2 2
3 12 1985.00 200 6.74 3042 4101 4.34 / 1376.72 2 2
4 7 1978.76 24 9.19 3192 704 5.05 / 1377.42 2 2
5 13 1259.80 51 11.51 2177 1278 6.32 / 1378.70 2 2
6 13 301.52 51 13.43 778 533 6.86 / 1379.23 2 5
7 8 -0.08 160 14.15 292 661 7.52 / 1379.89 2 8
Average= 5.43 (KJ/cycle)

Cycle 252 GMT 13/ 3/2023 16:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 28 14.06 448 176 0.18 / 1366.74 2 2
2 12 1139.80 200 5.48 1684 1846 2.02 / 1368.58 2 2
3 7 1144.68 24 9.39 1976 445 2.47 / 1369.03 2 2
4 13 1232.20 51 9.59 2095 1025 3.49 / 1370.05 2 2
5 13 1135.52 51 10.36 1993 1053 4.55 / 1371.11 2 2
6 13 394.72 51 12.95 920 608 5.15 / 1371.71 2 4
7 8 -0.04 160 14.11 294 664 5.82 / 1372.38 2 9
Average= 5.42 (KJ/cycle)

Cycle 251 GMT 3/ 3/2023 22: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 28 14.06 438 172 0.17 / 1360.77 2 2
2 12 1120.36 200 5.53 1866 2064 2.24 / 1362.84 2 2
3 7 1125.48 24 9.64 1958 453 2.69 / 1363.29 2 2
4 13 1199.24 51 9.91 2053 1038 3.73 / 1364.33 2 2
5 13 1083.28 51 10.66 1898 1032 4.76 / 1365.36 2 2
6 13 317.88 51 13.16 806 541 5.30 / 1365.90 2 5
7 8 -0.08 160 14.11 292 659 5.96 / 1366.56 2 9
Average= 5.42 (KJ/cycle)

Cycle 250 GMT 22/ 2/2023 3:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 28 14.13 438 173 0.17 / 1356.54 2 2
2 12 1126.48 200 6.63 1893 2510 2.68 / 1359.05 2 2
3 7 1119.28 24 10.12 1969 478 3.16 / 1359.53 2 2
4 13 182.68 51 13.61 591 410 3.57 / 1359.94 2 5
5 8 -0.04 160 14.16 293 664 4.24 / 1360.60 2 9
Average= 5.42 (KJ/cycle)

Cycle 249 GMT 12/ 2/2023 9:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 28 14.08 445 175 0.18 / 1348.81 2 2
2 12 1114.04 3 10.78 1965 64 0.24 / 1348.88 2 2
3 12 1987.12 200 6.77 3104 4203 4.44 / 1353.08 2 2
4 7 1981.20 25 9.49 3199 759 5.20 / 1353.84 2 2
5 13 1385.76 51 11.46 2370 1385 6.59 / 1355.22 2 2
6 13 239.00 51 13.62 685 476 7.06 / 1355.70 2 6
7 8 -0.16 160 14.20 294 668 7.73 / 1356.37 2 9
Average= 5.43 (KJ/cycle)

Cycle 248 GMT 11/ 2/2023 6:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 28 14.05 446 175 0.18 / 1342.79 2 2
2 12 1161.28 200 5.50 1775 1952 2.13 / 1344.74 2 2
3 7 1166.76 24 9.59 2031 467 2.60 / 1345.21 2 2
4 13 1247.88 51 10.16 2130 1104 3.70 / 1346.31 2 2
5 13 1139.64 51 10.77 1992 1094 4.79 / 1347.41 2 2
6 13 335.92 51 13.22 833 562 5.35 / 1347.97 2 5
7 8 -0.08 160 14.14 295 667 6.02 / 1348.64 2 14
Average= 5.42 (KJ/cycle)

Cycle 247 GMT 1/ 2/2023 12:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 28 14.06 442 174 0.17 / 1336.67 2 2
2 12 1153.12 200 5.53 1891 2091 2.27 / 1338.76 2 2
3 7 1158.12 24 9.64 2007 464 2.73 / 1339.22 2 2
4 13 1235.44 51 10.13 2109 1090 3.82 / 1340.31 2 2
5 13 1127.16 51 10.69 1965 1071 4.89 / 1341.38 2 2
6 13 352.64 51 13.15 854 573 5.46 / 1341.96 2 5
7 8 0.08 160 14.14 291 658 6.12 / 1342.61 2 9
Average= 5.41 (KJ/cycle)

Cycle 246 GMT 22/ 1/2023 17:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 28 14.11 447 177 0.18 / 1332.41 2 2
2 12 1120.48 200 6.64 1896 2518 2.69 / 1334.93 2 2
3 7 1113.84 24 10.20 1950 477 3.17 / 1335.40 2 2
4 13 209.32 51 13.56 631 436 3.61 / 1335.84 2 5
5 8 -0.04 160 14.16 288 652 4.26 / 1336.49 2 9
Average= 5.41 (KJ/cycle)

Cycle 245 GMT 13/ 1/2023 0: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 28 14.03 454 178 0.18 / 1324.61 2 2
2 12 1119.32 3 10.65 1993 64 0.24 / 1324.67 2 2
3 12 1986.36 200 6.64 3108 4127 4.37 / 1328.80 2 2
4 7 1980.20 24 9.62 3221 744 5.11 / 1329.54 2 2
5 13 1401.40 51 11.58 2376 1403 6.52 / 1330.95 2 2
6 13 392.20 51 13.34 913 621 7.14 / 1331.57 2 5
7 8 -0.04 160 14.20 292 663 7.80 / 1332.23 2 13
Average= 5.42 (KJ/cycle)

Cycle 244 GMT 11/ 1/2023 21: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 28 14.07 437 172 0.17 / 1318.67 2 2
2 12 1140.56 200 5.51 1806 1990 2.16 / 1320.66 2 2
3 7 1146.24 24 9.79 1997 469 2.63 / 1321.13 2 2
4 13 1231.48 51 10.47 2113 1128 3.76 / 1322.25 2 2
5 13 1118.60 51 11.04 1952 1099 4.86 / 1323.35 2 2
6 13 191.84 51 13.67 599 418 5.28 / 1323.77 2 5
7 8 0.00 160 14.16 291 659 5.94 / 1324.43 2 10
Average= 5.41 (KJ/cycle)

Cycle 243 GMT 2/ 1/2023 2:28: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 28 14.08 445 175 0.18 / 1312.60 2 2
2 12 1143.24 200 5.55 1941 2155 2.33 / 1314.75 2 2
3 7 1148.24 24 9.83 2003 473 2.80 / 1315.22 2 2
4 13 1215.68 51 10.45 2095 1117 3.92 / 1316.34 2 2
5 13 1105.32 51 10.96 1946 1088 5.01 / 1317.43 2 2
6 13 184.88 51 13.66 590 411 5.42 / 1317.84 2 5
7 8 -0.04 160 14.16 290 657 6.07 / 1318.50 2 6
Average= 5.40 (KJ/cycle)

Cycle 242 GMT 23/12/2022 7:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 28 14.15 437 173 0.17 / 1308.34 2 2
2 12 1117.48 200 6.76 1901 2570 2.74 / 1310.91 2 2
3 7 1109.84 24 10.32 1951 483 3.23 / 1311.39 2 2
4 13 154.12 51 13.74 540 378 3.60 / 1311.77 2 4
5 8 0.04 160 14.17 287 651 4.26 / 1312.42 2 8
Average= 5.40 (KJ/cycle)

Cycle 241 GMT 13/12/2022 14: 9: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 28 14.08 446 176 0.18 / 1300.51 2 2
2 12 1110.52 3 10.57 1949 62 0.24 / 1300.58 2 2
3 12 1989.12 200 6.55 3157 4136 4.37 / 1304.71 2 2
4 7 1983.60 24 9.89 3215 763 5.14 / 1305.47 2 2
5 13 1444.44 51 11.65 2446 1453 6.59 / 1306.93 2 2
6 13 336.60 51 13.49 834 574 7.16 / 1307.50 2 6
7 8 -0.20 160 14.20 292 663 7.83 / 1308.16 2 15
Average= 5.41 (KJ/cycle)

Cycle 240 GMT 12/12/2022 10:55:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 28 14.08 443 175 0.17 / 1294.52 2 2
2 12 1159.92 200 5.52 1800 1987 2.16 / 1296.51 2 2
3 7 1165.28 24 9.87 2031 481 2.64 / 1296.99 2 2
4 13 1242.48 51 10.52 2138 1147 3.79 / 1298.14 2 2
5 13 1129.92 51 11.15 1962 1116 4.91 / 1299.25 2 2
6 13 196.80 51 13.67 613 427 5.33 / 1299.68 2 5
7 8 -0.12 160 14.17 290 657 5.99 / 1300.34 2 7
Average= 5.40 (KJ/cycle)

Cycle 239 GMT 2/12/2022 16:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 28 14.07 446 176 0.18 / 1288.67 2 2
2 12 1149.04 200 5.68 1945 2210 2.39 / 1290.88 2 2
3 7 1152.80 24 9.97 1999 478 2.86 / 1291.36 2 2
4 13 1177.76 51 10.73 2038 1115 3.98 / 1292.48 2 2
5 13 784.92 51 12.18 1491 926 4.90 / 1293.40 2 3
6 13 71.04 51 13.96 401 285 5.19 / 1293.69 2 4
7 8 -0.04 160 14.17 291 660 5.85 / 1294.35 2 9
Average= 5.39 (KJ/cycle)

Cycle 238 GMT 22/11/2022 22: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 28 14.14 441 175 0.17 / 1284.39 2 2
2 3 1012.48 1 10.23 1847 19 0.19 / 1284.41 2 2
3 12 1113.08 200 6.80 1893 2574 2.77 / 1286.98 2 2
4 7 1105.24 24 10.33 1951 484 3.25 / 1287.47 2 2
5 13 152.96 51 13.75 539 378 3.63 / 1287.85 2 5
6 8 -0.12 160 14.17 287 651 4.28 / 1288.50 2 6
Average= 5.39 (KJ/cycle)

Cycle 237 GMT 13/11/2022 4:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 28 14.08 441 174 0.17 / 1276.24 2 2
2 12 1114.96 3 10.38 1963 61 0.23 / 1276.30 2 2
3 12 1987.80 200 6.37 3132 3990 4.23 / 1280.29 2 2
4 7 1982.76 24 10.02 3228 776 5.00 / 1281.07 2 2
5 13 1582.92 51 11.52 2637 1549 6.55 / 1282.62 2 2
6 13 482.80 51 13.26 1052 711 7.26 / 1283.33 2 5
7 13 14.64 51 14.15 308 222 7.48 / 1283.55 2 4
8 8 -0.12 160 14.23 291 663 8.15 / 1284.22 2 15
Average= 5.40 (KJ/cycle)

Cycle 236 GMT 12/11/2022 1: 7:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 28 13.99 438 172 0.17 / 1270.20 2 2
2 12 1157.88 200 5.52 1846 2038 2.21 / 1272.24 2 2
3 7 1162.24 24 9.88 2024 480 2.69 / 1272.72 2 2
4 13 1233.28 51 10.61 2114 1144 3.83 / 1273.87 2 2
5 13 1114.68 51 11.16 1970 1121 4.95 / 1274.99 2 2
6 13 184.72 51 13.69 600 419 5.37 / 1275.41 2 5
7 8 -0.16 160 14.16 293 664 6.04 / 1276.07 2 8
Average= 5.38 (KJ/cycle)

Cycle 235 GMT 2/11/2022 6:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 28 14.04 429 169 0.17 / 1265.61 2 2
2 12 1134.84 200 6.04 1885 2277 2.45 / 1267.89 2 2
3 7 1129.08 24 9.96 1980 473 2.92 / 1268.36 2 2
4 13 562.24 51 12.70 1165 755 3.67 / 1269.11 2 3
5 13 43.92 51 13.99 357 255 3.93 / 1269.37 2 4
6 8 0.08 160 14.14 293 663 4.59 / 1270.03 2 17
Average= 5.38 (KJ/cycle)

Cycle 234 GMT 23/10/2022 12:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 28 14.10 452 178 0.18 / 1261.28 2 2
2 12 1091.36 200 7.12 1872 2666 2.84 / 1263.94 2 2
3 7 1083.56 25 10.41 1933 503 3.35 / 1264.44 2 2
4 13 118.04 51 13.82 486 343 3.69 / 1264.79 2 5
5 8 0.00 160 14.15 289 654 4.34 / 1265.44 2 5
Average= 5.38 (KJ/cycle)

Cycle 233 GMT 13/10/2022 19: 2:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 28 14.08 441 174 0.17 / 1253.31 2 2
2 12 1116.88 3 10.44 1975 62 0.24 / 1253.37 2 2
3 12 1984.68 200 6.53 3215 4199 4.43 / 1257.57 2 2
4 7 1978.64 24 10.28 3224 795 5.23 / 1258.37 2 2
5 13 1368.24 51 11.95 2355 1435 6.67 / 1259.80 2 2
6 13 376.24 51 13.47 900 618 7.28 / 1260.42 2 5
7 8 -0.12 160 14.19 297 674 7.96 / 1261.10 2 9
Average= 5.39 (KJ/cycle)

Cycle 232 GMT 12/10/2022 16:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 28 14.02 447 175 0.18 / 1247.24 2 2
2 12 1131.56 200 5.57 1899 2115 2.29 / 1249.36 2 2
3 7 1136.28 24 10.04 1993 480 2.77 / 1249.84 2 2
4 13 1207.12 51 10.87 2088 1158 3.93 / 1251.00 2 2
5 13 1087.68 51 11.46 1933 1130 5.06 / 1252.13 2 2
6 13 128.16 51 13.83 500 353 5.41 / 1252.48 2 5
7 8 -0.12 160 14.16 291 659 6.07 / 1253.14 2 10
Average= 5.38 (KJ/cycle)

Cycle 231 GMT 2/10/2022 21:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 28 14.05 431 170 0.17 / 1242.59 2 2
2 12 1151.12 200 6.05 1914 2316 2.49 / 1244.90 2 2
3 7 1145.32 24 10.10 2014 488 2.97 / 1245.39 2 2
4 13 569.84 51 12.78 1176 766 3.74 / 1246.16 2 4
5 13 42.20 51 13.99 355 253 3.99 / 1246.41 2 5
6 8 -0.12 160 14.14 290 656 4.65 / 1247.07 2 12
Average= 5.38 (KJ/cycle)

Cycle 230 GMT 23/ 9/2022 3:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 28 14.12 445 176 0.18 / 1238.27 2 2
2 12 1108.00 200 7.05 1884 2656 2.83 / 1240.93 2 2
3 7 1100.12 24 10.42 1946 487 3.32 / 1241.42 2 2
4 13 128.40 51 13.81 500 352 3.67 / 1241.77 2 4
5 8 -0.16 160 14.15 288 652 4.32 / 1242.42 2 9
Average= 5.38 (KJ/cycle)

Cycle 229 GMT 13/ 9/2022 10: 7:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 28 14.06 438 172 0.17 / 1229.86 2 2
2 12 1120.84 3 10.03 1966 59 0.23 / 1229.92 2 2
3 12 1990.92 200 6.16 3102 3822 4.05 / 1233.74 2 2
4 7 1987.32 24 10.16 3233 788 4.84 / 1234.53 2 2
5 13 1860.08 51 11.18 3048 1738 6.58 / 1236.26 2 2
6 13 667.20 51 13.02 1327 881 7.46 / 1237.15 2 4
7 13 69.28 51 14.03 406 291 7.75 / 1237.44 2 5
8 8 -0.20 160 14.22 290 660 8.41 / 1238.10 2 5
Average= 5.38 (KJ/cycle)

Cycle 228 GMT 12/ 9/2022 7:30: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 28 14.04 445 175 0.17 / 1225.44 2 2
2 12 1130.40 200 5.99 1882 2255 2.43 / 1227.70 2 2
3 7 1124.16 24 10.16 1980 483 2.91 / 1228.18 2 2
4 13 673.28 51 12.56 1330 852 3.76 / 1229.03 2 3
5 8 0.20 160 14.15 288 652 4.42 / 1229.69 2 6
Average= 5.37 (KJ/cycle)

Cycle 227 GMT 2/ 9/2022 13:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 28 14.02 448 176 0.18 / 1221.09 2 2
2 12 1130.12 200 6.41 1897 2432 2.61 / 1223.53 2 2
3 7 1124.04 24 10.20 1981 485 3.09 / 1224.01 2 2
4 13 362.00 51 13.27 880 596 3.69 / 1224.61 2 5
5 8 -0.12 160 14.13 293 662 4.35 / 1225.27 2 11
Average= 5.37 (KJ/cycle)

Cycle 226 GMT 23/ 8/2022 19:52: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 28 14.13 431 171 0.17 / 1216.66 2 2
2 12 1117.04 200 7.25 1907 2765 2.94 / 1219.43 2 2
3 7 1108.88 24 10.52 1954 493 3.43 / 1219.92 2 2
4 13 109.44 51 13.84 475 335 3.76 / 1220.26 2 5
5 8 -0.16 160 14.12 292 660 4.42 / 1220.92 2 8
Average= 5.38 (KJ/cycle)

Cycle 225 GMT 14/ 8/2022 2:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 28 13.97 447 175 0.17 / 1208.02 2 2
2 12 1129.96 3 10.10 1970 60 0.23 / 1208.08 2 2
3 12 1998.80 200 6.17 3158 3897 4.13 / 1211.98 2 2
4 7 1995.80 24 10.29 3251 803 4.93 / 1212.78 2 2
5 13 1880.32 51 11.25 3080 1767 6.70 / 1214.55 2 2
6 13 792.80 51 12.87 1519 997 7.70 / 1215.54 2 4
7 13 62.04 51 14.05 395 283 7.98 / 1215.83 2 4
8 8 -0.16 160 14.23 293 667 8.65 / 1216.49 2 9
Average= 5.38 (KJ/cycle)

Cycle 224 GMT 12/ 8/2022 23:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 28 14.05 433 170 0.17 / 1203.62 2 2
2 12 1132.04 200 6.23 1896 2362 2.53 / 1205.98 2 2
3 7 1125.44 24 10.27 1980 488 3.02 / 1206.47 2 2
4 13 506.92 51 12.98 1090 722 3.74 / 1207.19 2 4
5 8 -0.08 160 14.14 290 656 4.40 / 1207.85 2 6
Average= 5.37 (KJ/cycle)

Cycle 223 GMT 3/ 8/2022 5:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 28 13.98 441 173 0.17 / 1199.40 2 2
2 12 1104.80 200 6.73 1874 2522 2.70 / 1201.92 2 2
3 7 1096.24 24 10.39 1937 483 3.18 / 1202.41 2 2
4 13 150.96 51 13.75 542 380 3.56 / 1202.79 2 5
5 8 -0.04 160 14.13 292 660 4.22 / 1203.45 2 11
Average= 5.37 (KJ/cycle)

Cycle 222 GMT 24/ 7/2022 11:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 28 14.14 440 174 0.17 / 1194.93 2 2
2 12 1099.04 200 7.55 1892 2857 3.03 / 1197.78 2 2
3 7 1091.28 24 10.61 1929 491 3.52 / 1198.27 2 2
4 13 79.20 51 13.90 422 299 3.82 / 1198.57 2 5
5 8 -0.28 160 14.12 290 655 4.48 / 1199.23 2 11
Average= 5.38 (KJ/cycle)

Cycle 221 GMT 14/ 7/2022 18:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 28 14.02 434 170 0.17 / 1186.33 2 2
2 12 1115.96 3 10.28 1962 61 0.23 / 1186.39 2 2
3 12 1997.60 200 6.25 3209 4011 4.24 / 1190.40 2 2
4 7 1993.76 24 10.39 3222 803 5.05 / 1191.20 2 2
5 13 1873.52 51 11.37 3062 1776 6.82 / 1192.98 2 2
6 13 643.24 51 13.11 1290 863 7.68 / 1193.84 2 4
7 13 30.32 51 14.11 341 245 7.93 / 1194.08 2 4
8 8 0.08 160 14.25 293 668 8.60 / 1194.75 2 11
Average= 5.38 (KJ/cycle)

Cycle 220 GMT 13/ 7/2022 15: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 28 14.04 443 174 0.17 / 1181.96 2 2
2 12 1126.72 200 6.52 1899 2476 2.65 / 1184.43 2 2
3 7 1119.84 24 10.41 1968 492 3.14 / 1184.93 2 2
4 13 331.04 51 13.37 828 565 3.71 / 1185.49 2 6
5 8 -0.24 160 14.11 294 664 4.37 / 1186.15 2 10
Average= 5.37 (KJ/cycle)

Cycle 219 GMT 3/ 7/2022 21:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 28 14.00 442 173 0.17 / 1177.68 2 2
2 12 1109.40 200 6.91 1884 2604 2.78 / 1180.28 2 2
3 7 1102.52 24 10.43 1960 491 3.27 / 1180.77 2 2
4 13 131.68 51 13.79 508 357 3.62 / 1181.13 2 5
5 8 -0.12 160 14.12 291 657 4.28 / 1181.78 2 6
Average= 5.37 (KJ/cycle)

Cycle 218 GMT 24/ 6/2022 3:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 28 14.13 441 174 0.17 / 1173.17 2 2
2 12 1108.04 200 7.66 1906 2920 3.09 / 1176.09 2 2
3 7 1099.36 24 10.66 1951 499 3.59 / 1176.58 2 2
4 13 45.96 51 13.97 364 259 3.85 / 1176.84 2 4
5 8 -0.08 160 14.13 291 658 4.51 / 1177.50 2 9
Average= 5.38 (KJ/cycle)

Cycle 217 GMT 14/ 6/2022 10: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 28 13.96 443 173 0.17 / 1164.52 2 2
2 12 1100.72 3 10.29 1944 60 0.23 / 1164.58 2 2
3 12 1997.00 200 6.35 3222 4092 4.33 / 1168.67 2 2
4 7 1992.64 24 10.36 3266 812 5.14 / 1169.49 2 2
5 13 1861.96 51 11.46 3048 1781 6.92 / 1171.27 2 2
6 13 582.44 51 13.21 1201 809 7.73 / 1172.08 2 4
7 13 19.28 51 14.14 328 237 7.96 / 1172.31 2 5
8 8 -0.12 160 14.23 298 678 8.64 / 1172.99 2 13
Average= 5.38 (KJ/cycle)

Cycle 216 GMT 13/ 6/2022 6:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 28 14.00 432 169 0.17 / 1160.25 2 2
2 12 1125.16 200 6.76 1897 2565 2.73 / 1162.81 2 2
3 7 1117.36 24 10.47 1967 494 3.23 / 1163.31 2 2
4 13 149.96 51 13.74 540 378 3.61 / 1163.69 2 5
5 8 -0.08 160 14.10 294 663 4.27 / 1164.35 2 10
Average= 5.37 (KJ/cycle)

Cycle 215 GMT 3/ 6/2022 12:59: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 28 14.05 427 168 0.17 / 1155.85 2 2
2 12 1131.12 200 7.02 1928 2707 2.87 / 1158.56 2 2
3 7 1123.80 24 10.49 1987 500 3.38 / 1159.06 2 2
4 13 133.00 51 13.75 517 363 3.74 / 1159.42 2 5
5 8 -0.20 160 14.10 292 659 4.40 / 1160.08 2 10
Average= 5.37 (KJ/cycle)

Cycle 214 GMT 24/ 5/2022 19:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 28 14.08 438 173 0.17 / 1151.31 2 2
2 12 1098.08 200 7.80 1908 2976 3.15 / 1154.29 2 2
3 7 1089.12 24 10.66 1927 493 3.64 / 1154.78 2 2
4 13 33.36 51 13.99 343 245 3.89 / 1155.03 2 4
5 8 0.04 160 14.12 289 653 4.54 / 1155.68 2 9
Average= 5.38 (KJ/cycle)

Cycle 213 GMT 15/ 5/2022 1:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 28 14.03 440 173 0.17 / 1143.26 2 2
2 12 1105.68 3 10.39 1940 60 0.23 / 1143.32 2 2
3 12 1987.56 200 6.49 3214 4172 4.41 / 1147.49 2 2
4 7 1981.44 24 10.48 3213 808 5.21 / 1148.30 2 2
5 13 1531.44 51 11.92 2565 1559 6.77 / 1149.86 2 2
6 13 365.84 51 13.52 885 610 7.38 / 1150.47 2 7
7 8 -0.04 160 14.20 297 675 8.06 / 1151.14 2 12
Average= 5.38 (KJ/cycle)

Cycle 212 GMT 13/ 5/2022 22:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 28 13.98 443 173 0.17 / 1138.94 2 2
2 12 1135.28 200 6.76 1916 2590 2.76 / 1141.53 2 2
3 7 1127.92 24 10.50 1981 499 3.26 / 1142.03 2 2
4 13 172.80 51 13.68 575 401 3.66 / 1142.43 2 5
5 8 -0.28 160 14.11 290 655 4.32 / 1143.08 2 10
Average= 5.37 (KJ/cycle)

Cycle 211 GMT 4/ 5/2022 5: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 28 14.01 442 173 0.17 / 1134.54 2 2
2 12 1125.44 200 7.11 1910 2716 2.89 / 1137.26 2 2
3 7 1117.64 25 10.55 1972 520 3.41 / 1137.78 2 2
4 13 113.40 51 13.81 477 336 3.75 / 1138.11 2 4
5 8 -0.24 160 14.11 290 655 4.40 / 1138.77 2 16
Average= 5.37 (KJ/cycle)

Cycle 210 GMT 24/ 4/2022 11:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 28 14.10 440 174 0.17 / 1130.00 2 2
2 12 1101.88 200 7.89 1900 2998 3.17 / 1132.99 2 2
3 7 1092.80 24 10.69 1927 494 3.67 / 1133.49 2 2
4 13 15.12 51 14.03 309 221 3.89 / 1133.71 2 4
5 8 -0.08 160 14.11 291 657 4.54 / 1134.37 2 11
Average= 5.38 (KJ/cycle)

Cycle 209 GMT 14/ 4/2022 18: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 28 14.03 435 171 0.17 / 1123.12 2 2
2 12 1097.96 3 10.42 1930 60 0.23 / 1123.18 2 2
3 12 1983.12 200 6.77 3167 4288 4.52 / 1127.47 2 2
4 7 1975.20 24 10.48 3205 806 5.33 / 1128.27 2 2
5 13 664.52 51 13.07 1323 882 6.21 / 1129.16 2 4
6 8 -0.04 160 14.21 293 666 6.87 / 1129.82 2 7
Average= 5.38 (KJ/cycle)

Cycle 208 GMT 13/ 4/2022 15:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 28 13.98 437 171 0.17 / 1118.80 2 2
2 12 1122.60 200 6.94 1905 2644 2.82 / 1121.44 2 2
3 7 1115.04 24 10.57 1966 499 3.31 / 1121.94 2 2
4 13 130.44 51 13.78 501 352 3.67 / 1122.29 2 4
5 8 -0.16 160 14.11 290 655 4.32 / 1122.95 2 8
Average= 5.37 (KJ/cycle)

Cycle 207 GMT 3/ 4/2022 21:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 28 13.94 450 176 0.18 / 1114.36 2 2
2 12 1114.48 200 7.32 1907 2792 2.97 / 1117.15 2 2
3 7 1106.60 24 10.61 1958 499 3.47 / 1117.65 2 2
4 13 106.64 51 13.83 463 327 3.79 / 1117.97 2 4
5 8 -0.04 160 14.11 289 652 4.45 / 1118.63 2 8
Average= 5.38 (KJ/cycle)

Cycle 206 GMT 25/ 3/2022 3:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 28 14.10 442 175 0.17 / 1109.92 2 2
2 12 1108.04 200 8.12 1912 3105 3.28 / 1113.03 2 2
3 7 1097.88 24 10.79 1939 502 3.78 / 1113.53 2 2
4 8 0.08 160 14.10 289 652 4.43 / 1114.18 2 7
Average= 5.38 (KJ/cycle)

Cycle 205 GMT 15/ 3/2022 10:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 28 14.02 452 177 0.18 / 1103.00 2 2
2 12 1115.00 3 10.52 1951 62 0.24 / 1103.06 2 2
3 12 1991.92 200 7.03 3183 4475 4.71 / 1107.54 2 2
4 7 1984.48 24 10.50 3223 812 5.53 / 1108.35 2 2
5 13 501.84 51 13.31 1076 730 6.26 / 1109.08 2 5
6 8 -0.08 160 14.20 295 670 6.93 / 1109.75 2 7
Average= 5.39 (KJ/cycle)

Cycle 204 GMT 14/ 3/2022 7:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 28 13.96 447 175 0.17 / 1098.55 2 2
2 12 1128.20 200 7.22 1920 2772 2.95 / 1101.32 2 2
3 7 1119.60 24 10.67 1978 507 3.45 / 1101.83 2 2
4 13 113.56 51 13.81 474 334 3.79 / 1102.16 2 5
5 8 -0.12 160 14.12 291 657 4.44 / 1102.82 2 9
Average= 5.38 (KJ/cycle)

Cycle 203 GMT 4/ 3/2022 14: 9: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 28 14.02 433 170 0.17 / 1093.98 2 2
2 12 1133.52 200 7.45 1944 2897 3.07 / 1096.88 2 2
3 7 1125.48 24 10.73 1978 509 3.58 / 1097.39 2 2
4 13 108.36 51 13.83 466 329 3.90 / 1097.72 2 5
5 8 -0.16 160 14.11 291 657 4.56 / 1098.38 2 8
Average= 5.38 (KJ/cycle)

Cycle 202 GMT 22/ 2/2022 20:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 28 14.10 448 177 0.18 / 1089.43 2 2
2 12 1133.44 200 8.21 1956 3212 3.39 / 1092.64 2 2
3 7 1124.44 24 10.85 1987 517 3.91 / 1093.16 2 2
4 8 0.24 160 14.11 292 659 4.57 / 1093.81 2 6
Average= 5.39 (KJ/cycle)

Cycle 201 GMT 13/ 2/2022 3: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 28 14.04 431 169 0.17 / 1082.35 2 2
2 12 1117.40 3 10.58 1974 63 0.23 / 1082.41 2 2
3 12 1986.72 200 7.35 3182 4678 4.91 / 1087.09 2 2
4 7 1978.64 24 10.58 3212 816 5.73 / 1087.91 2 2
5 13 422.52 51 13.41 972 665 6.39 / 1088.57 2 6
6 8 -0.16 160 14.19 298 677 7.07 / 1089.25 2 8
Average= 5.39 (KJ/cycle)

Cycle 200 GMT 12/ 2/2022 0:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 28 14.01 441 173 0.17 / 1077.90 2 2
2 12 1117.00 200 7.44 1916 2851 3.02 / 1080.75 2 2
3 7 1108.60 24 10.83 1967 511 3.54 / 1081.26 2 2
4 13 59.80 51 13.95 378 269 3.80 / 1081.53 2 4
5 8 0.04 160 14.11 288 650 4.45 / 1082.18 2 10
Average= 5.38 (KJ/cycle)

Cycle 199 GMT 2/ 2/2022 6:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 28 13.96 443 173 0.17 / 1073.32 2 2
2 12 1114.40 200 7.72 1908 2946 3.12 / 1076.26 2 2
3 7 1106.00 24 10.89 1961 513 3.63 / 1076.78 2 2
4 13 79.52 51 13.89 421 298 3.93 / 1077.07 2 5
5 8 -0.12 160 14.10 290 654 4.58 / 1077.73 2 13
Average= 5.39 (KJ/cycle)

Cycle 198 GMT 23/ 1/2022 13:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 28 14.05 451 177 0.18 / 1068.68 2 2
2 12 1105.20 200 8.55 1918 3280 3.46 / 1071.96 2 2
3 7 1095.92 24 11.04 1941 514 3.97 / 1072.48 2 2
4 8 0.00 160 14.09 296 667 4.64 / 1073.14 2 8
Average= 5.39 (KJ/cycle)

Cycle 197 GMT 13/ 1/2022 20: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 28 14.04 443 174 0.17 / 1061.39 2 2
2 12 1111.88 3 10.90 1954 64 0.24 / 1061.45 2 2
3 12 1980.40 200 8.04 3200 5146 5.38 / 1066.60 2 2
4 7 1971.32 24 10.75 3187 822 6.21 / 1067.42 2 2
5 13 170.56 51 13.79 579 407 6.61 / 1067.83 2 6
6 8 -0.08 160 14.18 299 678 7.29 / 1068.51 2 12
Average= 5.40 (KJ/cycle)

Cycle 196 GMT 12/ 1/2022 17:29: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 28 14.04 444 175 0.17 / 1056.76 2 2
2 12 1109.52 200 7.81 1903 2972 3.15 / 1059.73 2 2
3 7 1100.52 24 11.02 1959 518 3.67 / 1060.25 2 2
4 13 67.68 51 13.92 408 290 3.95 / 1060.54 2 5
5 8 -0.04 160 14.11 299 675 4.63 / 1061.21 2 11
Average= 5.39 (KJ/cycle)

Cycle 195 GMT 3/ 1/2022 0: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 28 14.05 446 175 0.18 / 1052.35 2 2
2 12 1109.76 200 7.94 1908 3030 3.21 / 1055.38 2 2
3 7 1101.16 24 11.08 1964 522 3.73 / 1055.91 2 2
4 8 0.04 160 14.14 300 679 4.41 / 1056.58 2 7
Average= 5.39 (KJ/cycle)

Cycle 194 GMT 24/12/2021 6:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 28 14.05 458 180 0.18 / 1048.36 2 2
2 12 1129.80 70 8.67 1940 1177 1.36 / 1049.53 2 2
3 7 1128.68 24 11.16 1982 531 1.89 / 1050.06 2 2
4 13 1013.76 51 12.23 1819 1135 3.02 / 1051.20 2 2
5 13 90.72 51 13.92 443 314 3.34 / 1051.51 2 5
6 8 -0.04 160 14.16 293 664 4.00 / 1052.18 2 10
Average= 5.40 (KJ/cycle)

Cycle 193 GMT 14/12/2021 12:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 28 14.04 450 177 0.18 / 1042.64 2 2
2 12 1115.40 3 11.18 1983 67 0.24 / 1042.71 2 2
3 12 1998.92 70 8.73 3188 1948 2.19 / 1044.65 2 2
4 7 1993.60 24 10.63 3242 827 3.02 / 1045.48 2 2
5 13 1423.88 51 12.08 2410 1485 4.50 / 1046.97 2 2
6 13 293.88 51 13.61 771 535 5.04 / 1047.50 2 7
7 8 -0.20 160 14.20 297 675 5.71 / 1048.18 2 12
Average= 5.40 (KJ/cycle)

Cycle 192 GMT 13/12/2021 9:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 23 14.06 435 141 0.14 / 1038.48 2 2
2 10 1012.48 3 12.31 1842 68 0.21 / 1038.55 2 2
3 3 1085.80 2 11.69 1951 46 0.25 / 1038.60 2 2
4 3 1045.08 1 11.43 1890 22 0.28 / 1038.62 2 2
5 12 1163.48 70 7.27 1956 995 1.27 / 1039.61 2 2
6 7 1164.32 24 10.70 2031 522 1.79 / 1040.14 2 2
7 13 1057.72 51 11.86 1886 1141 2.93 / 1041.28 2 2
8 13 283.04 51 13.54 755 521 3.46 / 1041.80 2 6
9 8 -0.08 160 14.15 294 666 4.12 / 1042.46 2 11
Average= 5.40 (KJ/cycle)

Cycle 191 GMT 3/12/2021 15:51: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 28 14.06 434 171 0.17 / 1034.69 2 2
2 12 1115.20 70 7.84 1903 1044 1.22 / 1035.73 2 2
3 7 1114.32 24 10.78 1959 507 1.72 / 1036.24 2 2
4 13 1008.32 51 11.88 1818 1101 2.82 / 1037.34 2 2
5 13 116.12 51 13.84 482 340 3.16 / 1037.68 2 4
6 8 -0.16 160 14.15 292 661 3.82 / 1038.34 2 8
Average= 5.41 (KJ/cycle)

Cycle 190 GMT 23/11/2021 21:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 28 14.16 428 170 0.17 / 1030.73 2 2
2 12 1110.00 70 8.97 1908 1198 1.37 / 1031.93 2 2
3 7 1107.64 24 11.08 1950 519 1.89 / 1032.45 2 2
4 13 976.24 51 12.12 1777 1098 2.98 / 1033.55 2 3
5 13 74.00 51 13.95 417 297 3.28 / 1033.84 2 4
6 8 -0.12 160 14.16 297 673 3.95 / 1034.52 2 8
Average= 5.42 (KJ/cycle)

Cycle 189 GMT 14/11/2021 4: 9: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 23 14.13 446 145 0.14 / 1024.90 2 2
2 10 1057.60 5 12.58 1907 120 0.26 / 1025.02 2 2
3 3 1062.56 2 11.67 1922 45 0.31 / 1025.06 2 2
4 3 1032.32 1 11.20 1858 21 0.33 / 1025.08 2 2
5 12 1144.92 5 11.60 2026 118 0.45 / 1025.20 2 2
6 12 1977.72 70 9.79 3194 2189 2.64 / 1027.39 2 2
7 7 1971.84 24 10.88 3204 837 3.47 / 1028.23 2 2
8 13 1205.56 51 12.54 2115 1353 4.83 / 1029.58 2 3
9 13 97.96 51 14.03 454 325 5.15 / 1029.91 2 5
10 8 0.20 160 14.28 288 658 5.81 / 1030.56 2 11
Average= 5.42 (KJ/cycle)

Cycle 188 GMT 13/11/2021 0:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 28 14.15 441 175 0.17 / 1016.82 2 2
2 12 1108.12 9 8.57 1926 149 0.32 / 1016.97 2 2
3 12 1979.52 140 5.95 3149 2623 2.95 / 1019.59 2 2
4 12 1974.12 70 7.12 3144 1567 4.51 / 1021.16 2 2
5 7 1968.80 24 10.48 3177 799 5.31 / 1021.96 2 2
6 13 1306.00 51 12.29 2251 1411 6.72 / 1023.37 2 3
7 13 476.76 51 13.42 1034 708 7.43 / 1024.07 2 6
8 8 -0.20 160 14.26 298 680 8.11 / 1024.75 2 10
Average= 5.42 (KJ/cycle)

Cycle 187 GMT 2/11/2021 23:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 28 14.18 456 181 0.18 / 1007.82 2 2
2 12 1123.16 9 8.93 1941 156 0.34 / 1007.98 2 2
3 12 2013.40 140 5.87 3193 2624 2.96 / 1010.60 2 2
4 12 2016.48 60 6.72 3307 1333 4.29 / 1011.94 2 2
5 7 2013.76 24 10.47 3253 817 5.11 / 1012.75 2 2
6 13 1897.80 51 11.38 3078 1786 6.90 / 1014.54 2 2
7 13 968.88 51 12.82 1777 1162 8.06 / 1015.70 2 4
8 13 63.20 51 14.13 391 282 8.34 / 1015.98 2 4
9 8 -0.12 160 14.31 288 659 9.00 / 1016.64 2 9
Average= 5.41 (KJ/cycle)

Cycle 186 GMT 23/10/2021 22:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 28 14.18 448 178 0.18 / 999.17 2 2
2 12 1124.76 9 8.74 1922 151 0.33 / 999.32 2 2
3 12 1985.28 140 5.90 3176 2623 2.95 / 1001.94 2 2
4 12 1984.88 60 6.94 3166 1318 4.27 / 1003.26 2 2
5 7 1980.76 24 10.48 3210 807 5.08 / 1004.07 2 2
6 13 1847.72 51 11.43 3008 1753 6.83 / 1005.82 2 2
7 13 694.20 51 13.16 1366 917 7.75 / 1006.74 2 4
8 13 15.80 51 14.24 315 229 7.98 / 1006.97 2 4
9 8 -0.04 160 14.31 294 673 8.65 / 1007.64 2 12
Average= 5.39 (KJ/cycle)

Cycle 185 GMT 13/10/2021 21:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 28 14.17 453 180 0.18 / 991.34 2 2
2 12 1117.12 9 8.92 1914 154 0.33 / 991.49 2 2
3 12 1989.24 80 5.89 3103 1462 1.80 / 992.96 2 2
4 12 1989.32 60 5.87 3276 1154 2.95 / 994.11 2 2
5 7 1989.04 24 10.21 3229 791 3.74 / 994.90 2 2
6 13 1911.76 51 11.04 3094 1742 5.48 / 996.64 2 2
7 13 1207.56 51 12.51 2114 1349 6.83 / 997.99 2 3
8 13 118.52 51 14.01 480 343 7.17 / 998.34 2 4
9 8 -0.08 160 14.30 287 657 7.83 / 998.99 2 9
Average= 5.37 (KJ/cycle)

Cycle 184 GMT 3/10/2021 20:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 28 14.21 434 173 0.17 / 983.61 2 2
2 12 1109.36 9 9.11 1921 158 0.33 / 983.77 2 2
3 12 1990.00 80 5.93 3214 1525 1.85 / 985.30 2 2
4 12 1988.84 60 6.35 3236 1233 3.09 / 986.53 2 2
5 7 1985.80 25 10.26 3223 827 3.91 / 987.36 2 2
6 13 1867.96 51 11.18 3020 1722 5.64 / 989.08 2 2
7 13 951.60 51 12.85 1746 1144 6.78 / 990.22 2 4
8 13 65.64 51 14.14 392 283 7.06 / 990.51 2 4
9 8 0.04 160 14.32 286 655 7.72 / 991.16 2 12
Average= 5.36 (KJ/cycle)

Cycle 183 GMT 23/ 9/2021 19:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 28 14.16 443 176 0.18 / 975.62 2 2
2 12 1138.72 9 8.86 1961 156 0.33 / 975.77 2 2
3 12 1978.64 80 5.91 3153 1491 1.82 / 977.27 2 2
4 12 1979.40 60 5.94 3267 1164 2.99 / 978.43 2 2
5 7 1978.52 24 10.30 3209 793 3.78 / 979.22 2 2
6 13 1885.28 51 11.16 3051 1737 5.52 / 980.96 2 2
7 13 1304.36 51 12.43 2251 1427 6.94 / 982.39 2 3
8 13 160.20 51 13.92 557 395 7.34 / 982.78 2 6
9 8 -0.08 160 14.28 289 660 8.00 / 983.44 2 11
Average= 5.34 (KJ/cycle)

Cycle 182 GMT 13/ 9/2021 18:14: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 28 14.17 445 177 0.18 / 968.20 2 2
2 12 1118.60 9 8.90 1938 155 0.33 / 968.36 2 2
3 12 1985.80 80 5.91 3153 1491 1.82 / 969.85 2 2
4 12 1986.04 35 5.86 3282 673 2.50 / 970.52 2 2
5 7 1986.08 24 10.12 3218 782 3.28 / 971.30 2 2
6 13 1901.68 51 10.94 3080 1718 5.00 / 973.02 2 2
7 13 1186.56 51 12.54 2070 1324 6.32 / 974.35 2 3
8 13 193.44 51 13.84 613 433 6.75 / 974.78 2 6
9 8 -0.20 160 14.26 291 664 7.42 / 975.44 2 11
Average= 5.33 (KJ/cycle)

Cycle 181 GMT 3/ 9/2021 17: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 28 14.17 442 175 0.18 / 961.17 2 2
2 12 1117.84 9 8.88 1946 156 0.33 / 961.33 2 2
3 12 1980.04 80 5.98 3203 1532 1.86 / 962.86 2 2
4 12 1978.88 35 6.75 3138 741 2.60 / 963.60 2 2
5 7 1975.60 24 10.19 3186 779 3.38 / 964.38 2 2
6 13 1858.20 51 11.03 3016 1697 5.08 / 966.07 2 2
7 13 801.64 51 13.00 1524 1010 6.09 / 967.09 2 4
8 13 61.48 51 14.11 393 283 6.37 / 967.37 2 5
9 8 -0.16 160 14.29 288 658 7.03 / 968.03 2 12
Average= 5.32 (KJ/cycle)

Cycle 180 GMT 24/ 8/2021 16: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 27 14.18 443 170 0.17 / 953.79 2 2
2 12 1135.96 9 8.93 1950 157 0.33 / 953.95 2 2
3 12 1984.60 80 5.92 3211 1521 1.85 / 955.47 2 2
4 12 1984.20 35 6.22 3250 708 2.55 / 956.18 2 2
5 7 1982.52 24 10.22 3207 787 3.34 / 956.96 2 2
6 13 1872.40 51 11.11 3035 1720 5.06 / 958.68 2 2
7 13 1125.20 51 12.66 2001 1292 6.35 / 959.97 2 3
8 13 117.04 51 13.99 492 351 6.70 / 960.33 2 6
9 8 -0.20 160 14.27 293 669 7.37 / 960.99 2 11
Average= 5.31 (KJ/cycle)

Cycle 179 GMT 14/ 8/2021 15: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 27 14.13 442 169 0.17 / 946.32 2 2
2 12 1132.40 10 8.97 1948 175 0.34 / 946.49 2 2
3 12 1987.68 110 5.89 3194 2069 2.41 / 948.56 2 2
4 7 1987.84 24 10.20 3220 788 3.20 / 949.35 2 2
5 13 1910.72 51 11.02 3094 1739 4.94 / 951.09 2 2
6 13 1341.00 51 12.41 2307 1460 6.40 / 952.55 2 2
7 13 164.92 51 13.90 567 402 6.80 / 952.95 2 6
8 8 -0.12 160 14.26 293 669 7.47 / 953.62 2 11
Average= 5.30 (KJ/cycle)

Cycle 178 GMT 4/ 8/2021 13:56: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 27 14.22 437 168 0.17 / 940.19 2 2
2 12 1142.92 10 9.14 1976 181 0.35 / 940.37 2 2
3 12 1958.88 110 6.62 3118 2271 2.62 / 942.64 2 2
4 7 1954.36 24 10.21 3136 768 3.39 / 943.41 2 2
5 13 1418.28 51 12.08 2419 1490 4.88 / 944.90 2 2
6 13 323.80 51 13.61 821 570 5.45 / 945.47 2 7
7 8 -0.16 160 14.20 301 684 6.13 / 946.15 2 10
Average= 5.29 (KJ/cycle)

Cycle 177 GMT 25/ 7/2021 12:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 28 14.20 444 177 0.18 / 932.81 2 2
2 12 1116.12 10 9.03 1938 175 0.35 / 932.98 2 2
3 12 1989.48 105 5.91 3230 2004 2.36 / 934.99 2 2
4 7 1989.48 24 10.20 3209 786 3.14 / 935.77 2 2
5 13 1909.52 51 11.08 3103 1753 4.89 / 937.53 2 2
6 13 1349.32 51 12.41 2335 1478 6.37 / 939.01 2 3
7 13 113.80 51 14.01 483 345 6.72 / 939.35 2 5
8 8 0.00 160 14.28 293 669 7.39 / 940.02 2 9
Average= 5.28 (KJ/cycle)

Cycle 176 GMT 15/ 7/2021 11:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 27 14.23 439 169 0.17 / 926.15 2 2
2 12 1122.68 10 9.27 1942 180 0.35 / 926.33 2 2
3 12 1988.24 105 6.52 3123 2138 2.49 / 928.46 2 2
4 7 1983.36 24 10.27 3196 788 3.27 / 929.25 2 2
5 13 1695.04 51 11.55 2815 1658 4.93 / 930.91 2 2
6 13 571.08 51 13.30 1180 800 5.73 / 931.71 2 6
7 13 15.52 51 14.21 318 230 5.96 / 931.94 2 5
8 8 -0.28 160 14.25 303 691 6.65 / 932.63 2 17
Average= 5.27 (KJ/cycle)

Cycle 175 GMT 5/ 7/2021 10:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 27 14.19 436 167 0.17 / 919.07 2 2
2 12 1133.24 10 9.44 1968 186 0.35 / 919.26 2 2
3 12 2001.24 105 6.25 3235 2123 2.48 / 921.38 2 2
4 7 1998.44 24 10.40 3240 809 3.28 / 922.19 2 2
5 13 1874.80 51 11.30 3038 1751 5.04 / 923.94 2 2
6 13 870.76 51 12.97 1627 1076 6.11 / 925.02 2 4
7 13 81.00 51 14.09 422 303 6.41 / 925.32 2 5
8 8 -0.24 160 14.28 287 656 7.07 / 925.98 2 9
Average= 5.26 (KJ/cycle)

Cycle 174 GMT 25/ 6/2021 10:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 27 14.22 422 162 0.16 / 912.53 2 2
2 12 1114.76 10 8.88 1941 172 0.33 / 912.70 2 2
3 12 1990.48 76 6.03 3168 1452 1.79 / 914.16 2 2
4 7 1989.76 24 10.30 3209 793 2.58 / 914.95 2 2
5 13 1901.00 51 11.12 3087 1751 4.33 / 916.70 2 2
6 13 1057.16 51 12.76 1874 1220 5.55 / 917.92 2 4
7 13 119.68 51 14.03 477 341 5.89 / 918.26 2 5
8 8 -0.04 160 14.29 283 647 6.54 / 918.91 2 9
Average= 5.25 (KJ/cycle)

Cycle 173 GMT 15/ 6/2021 8:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 27 14.19 440 169 0.17 / 905.78 2 2
2 12 1120.16 10 9.08 1933 176 0.34 / 905.95 2 2
3 12 2000.88 76 6.03 3231 1481 1.82 / 907.44 2 2
4 7 1999.92 24 10.44 3225 808 2.63 / 908.24 2 2
5 13 1892.84 51 11.28 3072 1767 4.40 / 910.01 2 2
6 13 1162.16 51 12.66 2045 1320 5.72 / 911.33 2 3
7 13 150.80 51 13.96 538 383 6.10 / 911.71 2 6
8 8 0.00 160 14.27 287 655 6.76 / 912.37 2 9
Average= 5.24 (KJ/cycle)

Cycle 172 GMT 5/ 6/2021 8: 4: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 27 14.20 457 175 0.18 / 899.42 2 2
2 12 1111.08 10 8.88 1921 171 0.35 / 899.59 2 2
3 12 1967.04 76 6.63 3117 1571 1.92 / 901.16 2 2
4 7 1963.28 24 10.53 3160 799 2.71 / 901.96 2 2
5 13 1838.76 51 11.40 2987 1737 4.45 / 903.70 2 2
6 13 778.16 51 13.07 1484 989 5.44 / 904.69 2 4
7 13 44.80 51 14.16 363 262 5.70 / 904.95 2 5
8 8 -0.12 160 14.27 290 662 6.37 / 905.61 2 13
Average= 5.23 (KJ/cycle)

Cycle 171 GMT 26/ 5/2021 7: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 27 14.20 453 174 0.17 / 892.93 2 2
2 12 1124.48 10 9.46 1970 186 0.36 / 893.12 2 2
3 12 2002.08 76 6.73 3151 1612 1.97 / 894.73 2 2
4 7 1998.76 24 10.59 3230 821 2.79 / 895.55 2 2
5 13 1864.44 51 11.46 3040 1777 4.57 / 897.33 2 2
6 13 762.20 51 13.10 1465 979 5.55 / 898.31 2 5
7 13 39.48 51 14.15 364 263 5.81 / 898.57 2 6
8 8 -0.24 160 14.25 297 677 6.49 / 899.25 2 12
Average= 5.23 (KJ/cycle)

Cycle 170 GMT 16/ 5/2021 6:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 28 14.16 456 181 0.18 / 886.92 2 2
2 12 1121.24 10 8.84 1926 170 0.35 / 887.09 2 2
3 12 1976.80 74 6.92 3140 1608 1.96 / 888.70 2 2
4 7 1973.08 24 10.62 3192 814 2.77 / 889.52 2 2
5 13 1578.84 48 12.08 2623 1521 4.29 / 891.04 2 2
6 13 630.80 48 13.28 1274 812 5.11 / 891.85 2 5
7 13 25.76 48 14.20 334 228 5.33 / 892.08 2 5
8 8 -0.16 160 14.25 299 682 6.01 / 892.76 2 13
Average= 5.22 (KJ/cycle)

Cycle 169 GMT 6/ 5/2021 5:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.60 27 14.21 461 177 0.18 / 880.82 2 2
2 12 1139.68 10 9.49 1995 189 0.37 / 881.01 2 2
3 12 1999.64 74 6.95 3158 1624 1.99 / 882.63 2 2
4 7 1995.44 24 10.70 3215 826 2.82 / 883.45 2 2
5 13 1586.92 48 12.10 2657 1543 4.36 / 885.00 2 2
6 13 653.08 48 13.25 1311 834 5.19 / 885.83 2 5
7 13 23.84 48 14.19 343 234 5.43 / 886.07 2 5
8 8 -0.16 160 14.25 297 677 6.10 / 886.74 2 15
Average= 5.22 (KJ/cycle)

Cycle 168 GMT 26/ 4/2021 5:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 27 14.24 442 170 0.17 / 874.65 2 2
2 12 1124.24 10 9.73 1964 191 0.36 / 874.84 2 2
3 12 2001.76 74 7.11 3188 1677 2.04 / 876.52 2 2
4 7 1998.16 24 10.70 3236 831 2.87 / 877.35 2 2
5 13 1870.60 48 11.64 3042 1700 4.57 / 879.05 2 2
6 13 746.96 48 13.16 1441 910 5.48 / 879.96 2 5
7 8 -0.08 160 14.26 298 680 6.16 / 880.64 2 8
Average= 5.21 (KJ/cycle)

Cycle 167 GMT 16/ 4/2021 5:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 27 14.18 436 167 0.17 / 868.24 2 2
2 12 1114.80 10 9.33 1934 180 0.35 / 868.42 2 2
3 12 2003.80 74 6.99 3178 1644 1.99 / 870.06 2 2
4 7 2000.68 24 10.73 3241 835 2.83 / 870.90 2 2
5 13 1879.56 48 11.67 3061 1715 4.54 / 872.61 2 2
6 13 778.28 48 13.14 1487 938 5.48 / 873.55 2 5
7 13 46.12 48 14.17 367 250 5.73 / 873.80 2 5
8 8 -0.08 160 14.26 299 682 6.41 / 874.48 2 11
Average= 5.21 (KJ/cycle)

Cycle 166 GMT 6/ 4/2021 4:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 27 14.25 433 167 0.17 / 862.18 2 2
2 12 1121.36 10 9.11 1944 177 0.34 / 862.36 2 2
3 12 1997.40 74 7.23 3182 1702 2.05 / 864.06 2 2
4 7 1993.60 24 10.80 3204 830 2.88 / 864.89 2 2
5 13 1860.28 48 11.71 3022 1699 4.58 / 866.59 2 2
6 13 632.32 48 13.30 1273 813 5.39 / 867.40 2 5
7 8 0.00 160 14.30 291 666 6.05 / 868.07 2 10
Average= 5.20 (KJ/cycle)

Cycle 165 GMT 27/ 3/2021 3:42: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 27 14.21 438 168 0.17 / 855.82 2 2
2 12 1113.08 9 9.35 1938 163 0.33 / 855.99 2 2
3 12 2007.72 71 7.34 3193 1664 2.00 / 857.65 2 2
4 7 2005.96 24 10.65 3233 826 2.82 / 858.48 2 2
5 13 1888.40 48 11.63 3071 1714 4.54 / 860.19 2 2
6 13 755.48 48 13.16 1454 918 5.45 / 861.11 2 5
7 13 43.68 48 14.22 355 242 5.70 / 861.35 2 4
8 8 -0.04 160 14.29 291 665 6.36 / 862.02 2 11
Average= 5.19 (KJ/cycle)

Cycle 164 GMT 17/ 3/2021 4: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 27 14.21 456 175 0.17 / 850.13 2 2
2 12 1133.80 9 8.99 1951 158 0.33 / 850.29 2 2
3 12 1999.96 71 7.50 3124 1664 2.00 / 851.95 2 2
4 7 1996.80 24 10.64 3232 825 2.82 / 852.78 2 2
5 13 1575.24 48 12.19 2619 1532 4.35 / 854.31 2 2
6 13 458.68 48 13.50 1028 666 5.02 / 854.98 2 6
7 8 0.00 160 14.26 297 678 5.70 / 855.65 2 11
Average= 5.19 (KJ/cycle)

Cycle 163 GMT 7/ 3/2021 4:19: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 27 14.26 432 166 0.17 / 844.05 2 2
2 12 1137.64 9 9.28 1946 163 0.33 / 844.21 2 2
3 12 2001.00 71 7.62 3141 1699 2.03 / 845.91 2 2
4 7 1998.08 24 10.67 3210 822 2.85 / 846.73 2 2
5 13 1731.80 48 11.99 2855 1643 4.49 / 848.38 2 2
6 13 742.96 48 13.19 1438 910 5.40 / 849.29 2 5
7 8 0.16 160 14.29 292 668 6.07 / 849.96 2 8
Average= 5.18 (KJ/cycle)

Cycle 162 GMT 25/ 2/2021 4:17: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 27 14.26 428 165 0.16 / 838.17 2 2
2 12 1118.40 9 9.87 1957 174 0.34 / 838.34 2 2
3 12 2005.12 71 8.00 3211 1824 2.16 / 840.17 2 2
4 7 2002.44 24 10.67 3234 828 2.99 / 840.99 2 2
5 13 1581.92 48 12.16 2653 1549 4.54 / 842.54 2 2
6 13 464.44 48 13.49 1027 665 5.20 / 843.21 2 6
7 8 -0.08 160 14.26 297 678 5.88 / 843.88 2 9
Average= 5.18 (KJ/cycle)

Cycle 161 GMT 15/ 2/2021 4:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 27 14.25 455 175 0.18 / 832.08 2 2
2 12 1114.32 9 9.17 1930 159 0.33 / 832.24 2 2
3 12 2001.60 71 7.86 3189 1780 2.11 / 834.02 2 2
4 7 1999.08 24 10.78 3214 832 2.95 / 834.85 2 2
5 13 1588.64 48 12.21 2650 1553 4.50 / 836.41 2 2
6 13 493.44 48 13.48 1066 690 5.19 / 837.10 2 6
7 13 28.88 48 14.23 342 234 5.42 / 837.33 2 5
8 8 -0.24 160 14.28 295 674 6.10 / 838.00 2 9
Average= 5.17 (KJ/cycle)

Cycle 160 GMT 5/ 2/2021 4:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 27 14.29 429 166 0.17 / 826.15 2 2
2 12 1124.28 9 9.48 1970 168 0.33 / 826.32 2 2
3 12 2005.20 64 7.90 3180 1608 1.94 / 827.93 2 2
4 7 2002.76 24 10.73 3246 836 2.78 / 828.76 2 2
5 13 1870.16 48 11.79 3028 1714 4.49 / 830.48 2 2
6 13 587.16 48 13.36 1198 768 5.26 / 831.25 2 5
7 8 0.16 160 14.29 289 661 5.92 / 831.91 2 8
Average= 5.17 (KJ/cycle)

Cycle 159 GMT 26/ 1/2021 5: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 27 14.28 431 166 0.17 / 820.33 2 2
2 12 1144.28 9 9.42 1979 168 0.33 / 820.49 2 2
3 12 2001.64 64 7.85 3138 1577 1.91 / 822.07 2 2
4 7 1998.64 24 10.79 3227 836 2.75 / 822.91 2 2
5 13 1728.36 48 12.02 2841 1639 4.39 / 824.54 2 2
6 13 601.76 48 13.35 1221 782 5.17 / 825.33 2 6
7 8 0.04 160 14.28 289 660 5.83 / 825.99 2 8
Average= 5.16 (KJ/cycle)

Cycle 158 GMT 16/ 1/2021 5: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 27 14.23 441 169 0.17 / 814.63 2 2
2 12 1115.64 9 9.39 1928 163 0.33 / 814.80 2 2
3 12 1999.72 59 7.99 3151 1485 1.82 / 816.28 2 2
4 7 1997.00 24 10.81 3224 836 2.65 / 817.12 2 2
5 13 1716.80 48 12.02 2828 1632 4.29 / 818.75 2 2
6 13 569.08 48 13.38 1168 750 5.04 / 819.50 2 5
7 8 -0.16 160 14.28 288 658 5.69 / 820.16 2 8
Average= 5.16 (KJ/cycle)

Cycle 157 GMT 6/ 1/2021 5:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 27 14.29 436 168 0.17 / 808.99 2 2
2 12 1134.48 9 9.43 1965 167 0.33 / 809.16 2 2
3 12 2001.52 59 8.18 3133 1512 1.85 / 810.67 2 2
4 7 1998.64 24 10.84 3232 841 2.69 / 811.51 2 2
5 13 1728.32 48 12.04 2832 1637 4.32 / 813.15 2 2
6 13 470.84 48 13.50 1024 664 4.99 / 813.81 2 6
7 8 0.00 160 14.28 285 651 5.64 / 814.46 2 8
Average= 5.15 (KJ/cycle)

Cycle 156 GMT 27/12/2020 5:14: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 27 14.24 436 168 0.17 / 803.18 2 2
2 12 1121.04 8 9.50 1946 148 0.32 / 803.33 2 2
3 12 2005.76 59 8.15 3140 1510 1.83 / 804.84 2 2
4 7 2003.20 24 10.85 3233 842 2.67 / 805.68 2 2
5 13 1869.96 48 11.78 3035 1716 4.38 / 807.40 2 2
6 13 580.32 48 13.37 1187 762 5.15 / 808.16 2 5
7 8 0.04 160 14.28 292 667 5.81 / 808.83 2 8
Average= 5.15 (KJ/cycle)

Cycle 155 GMT 17/12/2020 5:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 27 14.31 423 163 0.16 / 797.57 2 2
2 12 1123.08 8 9.74 1961 153 0.32 / 797.73 2 2
3 12 2000.40 59 8.36 3118 1538 1.85 / 799.26 2 2
4 7 1997.56 24 10.94 3215 844 2.70 / 800.11 2 2
5 13 1594.00 48 12.19 2685 1571 4.27 / 801.68 2 2
6 13 486.92 48 13.48 1041 674 4.94 / 802.35 2 6
7 8 -0.04 160 14.27 289 660 5.60 / 803.01 2 9
Average= 5.15 (KJ/cycle)

Cycle 154 GMT 7/12/2020 5:12: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 27 14.29 433 167 0.17 / 791.46 2 2
2 12 1127.80 6 9.08 1957 107 0.27 / 791.57 2 2
3 12 2001.36 57 8.32 3141 1490 1.76 / 793.06 2 2
4 7 1998.92 25 10.89 3215 875 2.64 / 793.93 2 2
5 13 1863.56 48 11.85 3027 1722 4.36 / 795.65 2 2
6 13 699.88 48 13.23 1368 869 5.23 / 796.52 2 5
7 13 32.40 48 14.23 340 232 5.46 / 796.76 2 5
8 8 -0.12 160 14.27 287 655 6.12 / 797.41 2 10
Average= 5.14 (KJ/cycle)

Cycle 153 GMT 27/11/2020 5:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 27 14.24 449 173 0.17 / 785.74 2 2
2 12 1142.92 6 9.60 1984 114 0.29 / 785.86 2 2
3 12 2002.12 57 8.46 3129 1509 1.80 / 787.37 2 2
4 7 1999.20 24 10.92 3225 845 2.64 / 788.21 2 2
5 13 1717.04 48 12.06 2830 1638 4.28 / 789.85 2 2
6 13 588.76 48 13.36 1202 771 5.05 / 790.62 2 6
7 8 -0.20 160 14.25 295 673 5.72 / 791.29 2 11
Average= 5.14 (KJ/cycle)

Cycle 152 GMT 17/11/2020 5:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 27 14.27 452 174 0.17 / 780.25 2 2
2 12 1109.76 4 7.88 1906 60 0.23 / 780.31 2 2
3 12 2001.56 54 8.48 3130 1433 1.67 / 781.74 2 2
4 7 1998.72 24 10.97 3211 845 2.51 / 782.59 2 2
5 13 1727.52 48 12.03 2855 1649 4.16 / 784.23 2 2
6 13 474.08 48 13.49 1032 668 4.83 / 784.90 2 6
7 8 0.00 160 14.26 293 669 5.50 / 785.57 2 10
Average= 5.13 (KJ/cycle)

Cycle 151 GMT 7/11/2020 6:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 27 14.27 451 174 0.17 / 774.67 2 2
2 12 1110.64 4 8.25 1923 63 0.24 / 774.74 2 2
3 12 1999.88 54 8.72 3131 1474 1.71 / 776.21 2 2
4 7 1997.04 24 10.98 3222 849 2.56 / 777.06 2 2
5 13 1715.12 48 12.07 2852 1652 4.21 / 778.71 2 2
6 13 494.88 48 13.47 1068 691 4.90 / 779.40 2 6
7 8 -0.12 160 14.26 294 671 5.57 / 780.07 2 10
Average= 5.13 (KJ/cycle)

Cycle 150 GMT 28/10/2020 6:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 27 14.25 457 176 0.18 / 768.69 2 2
2 12 1106.16 4 8.64 1937 67 0.24 / 768.75 2 2
3 12 2003.80 51 8.66 3174 1402 1.64 / 770.15 2 2
4 7 2001.32 24 10.99 3234 853 2.50 / 771.01 2 2
5 13 1871.84 48 11.85 3059 1740 4.24 / 772.75 2 2
6 13 631.48 48 13.30 1273 813 5.05 / 773.56 2 5
7 13 48.84 48 14.17 381 259 5.31 / 773.82 2 5
8 8 -0.28 160 14.25 298 679 5.99 / 774.50 2 13
Average= 5.13 (KJ/cycle)

Cycle 149 GMT 18/10/2020 6:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 27 14.30 449 173 0.17 / 763.09 2 2
2 12 1118.44 4 8.56 1982 68 0.24 / 763.15 2 2
3 12 2011.20 51 8.84 3134 1413 1.65 / 764.57 2 2
4 7 2008.80 24 11.03 3243 858 2.51 / 765.42 2 2
5 13 1874.24 48 11.87 3039 1732 4.24 / 767.16 2 2
6 13 498.60 48 13.45 1074 693 4.94 / 767.85 2 6
7 8 0.08 160 14.28 289 660 5.60 / 768.51 2 10
Average= 5.12 (KJ/cycle)

Cycle 148 GMT 8/10/2020 7: 7:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 27 14.30 448 173 0.17 / 757.33 2 2
2 12 1128.60 4 8.97 1956 70 0.24 / 757.41 2 2
3 12 2003.92 42 8.83 3131 1161 1.40 / 758.57 2 2
4 7 2001.80 24 11.12 3234 863 2.27 / 759.43 2 2
5 13 1879.56 48 11.88 3071 1751 4.02 / 761.18 2 2
6 13 632.76 48 13.30 1269 810 4.83 / 761.99 2 5
7 13 51.44 48 14.18 375 255 5.08 / 762.25 2 5
8 8 -0.24 160 14.26 292 666 5.75 / 762.91 2 13
Average= 5.12 (KJ/cycle)

Cycle 147 GMT 28/ 9/2020 7:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 27 14.30 447 173 0.17 / 751.50 2 2
2 12 1120.28 4 9.05 1960 71 0.24 / 751.57 2 2
3 12 2002.32 42 8.83 3122 1158 1.40 / 752.73 2 2
4 7 2000.28 24 10.99 3233 853 2.25 / 753.58 2 2
5 13 1872.36 48 11.85 3034 1726 3.98 / 755.31 2 2
6 13 755.24 48 13.16 1456 920 4.90 / 756.23 2 5
7 13 51.44 48 14.19 380 259 5.16 / 756.49 2 5
8 8 -0.20 160 14.27 295 674 5.83 / 757.16 2 11
Average= 5.12 (KJ/cycle)

Cycle 146 GMT 18/ 9/2020 8:18: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 27 14.30 459 177 0.18 / 745.73 2 2
2 12 1119.64 4 9.14 1940 71 0.25 / 745.80 2 2
3 12 2002.52 42 8.90 3117 1165 1.41 / 746.97 2 2
4 7 2000.08 24 11.11 3241 864 2.28 / 747.83 2 2
5 13 1732.88 48 12.06 2852 1651 3.93 / 749.48 2 2
6 13 763.92 48 13.15 1468 927 4.86 / 750.41 2 5
7 13 55.64 48 14.20 381 260 5.11 / 750.67 2 5
8 8 -0.08 160 14.29 289 661 5.78 / 751.33 2 11
Average= 5.11 (KJ/cycle)

Cycle 145 GMT 8/ 9/2020 8:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 27 14.29 444 171 0.17 / 739.83 2 2
2 12 1133.92 4 9.78 1998 78 0.25 / 739.91 2 2
3 12 2000.72 42 8.97 3105 1170 1.42 / 741.08 2 2
4 7 1998.12 24 11.06 3212 853 2.27 / 741.93 2 2
5 13 1862.56 48 11.86 3035 1728 4.00 / 743.66 2 2
6 13 743.00 48 13.16 1438 908 4.91 / 744.57 2 5
7 13 92.28 48 14.11 455 308 5.22 / 744.88 2 5
8 8 -0.20 160 14.25 298 679 5.90 / 745.55 2 10
Average= 5.11 (KJ/cycle)

Cycle 144 GMT 29/ 8/2020 9: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 27 14.28 427 165 0.16 / 734.19 2 2
2 12 1128.60 4 9.71 1979 77 0.24 / 734.26 2 2
3 12 2002.36 42 9.03 3119 1183 1.42 / 735.45 2 2
4 7 2000.00 24 11.08 3238 861 2.29 / 736.31 2 2
5 13 1728.88 48 12.07 2842 1647 3.93 / 737.95 2 2
6 13 621.04 48 13.29 1268 809 4.74 / 738.76 2 6
7 13 26.56 48 14.24 338 231 4.97 / 738.99 2 4
8 8 -0.04 160 14.27 291 664 5.64 / 739.66 2 12
Average= 5.10 (KJ/cycle)

Cycle 143 GMT 19/ 8/2020 9:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 27 14.29 432 167 0.17 / 728.55 2 2
2 12 1121.96 4 10.13 1980 80 0.25 / 728.63 2 2
3 12 1999.56 42 9.06 3118 1186 1.43 / 729.82 2 2
4 7 1996.88 24 11.13 3233 864 2.30 / 730.68 2 2
5 13 1719.64 48 12.06 2825 1635 3.93 / 732.32 2 2
6 13 599.28 48 13.34 1219 781 4.71 / 733.10 2 6
7 13 42.76 48 14.18 369 251 4.96 / 733.35 2 5
8 8 -0.08 160 14.24 295 672 5.64 / 734.02 2 14
Average= 5.10 (KJ/cycle)

Cycle 142 GMT 9/ 8/2020 9:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 27 14.31 433 167 0.17 / 722.92 2 2
2 12 1124.96 4 10.64 1992 85 0.25 / 723.01 2 2
3 12 1999.24 42 9.17 3144 1211 1.46 / 724.22 2 2
4 7 1996.32 24 11.13 3222 861 2.32 / 725.08 2 2
5 13 1714.08 48 12.06 2835 1641 3.96 / 726.72 2 2
6 13 581.84 48 13.35 1190 763 4.73 / 727.48 2 6
7 13 37.16 48 14.21 353 241 4.97 / 727.72 2 5
8 8 -0.24 160 14.24 291 663 5.63 / 728.39 2 13
Average= 5.09 (KJ/cycle)

Cycle 141 GMT 30/ 7/2020 10:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 27 14.27 440 170 0.17 / 717.25 2 2
2 12 1114.28 4 10.58 1965 83 0.25 / 717.33 2 2
3 12 2002.12 42 9.26 3139 1221 1.47 / 718.55 2 2
4 7 1999.80 24 11.18 3232 867 2.34 / 719.42 2 2
5 13 1731.04 48 12.05 2847 1647 3.99 / 721.07 2 2
6 13 591.52 48 13.33 1207 772 4.76 / 721.84 2 5
7 13 44.60 48 14.19 365 249 5.01 / 722.09 2 5
8 8 -0.20 160 14.25 293 668 5.68 / 722.76 2 10
Average= 5.09 (KJ/cycle)

Cycle 140 GMT 20/ 7/2020 10:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 27 14.28 450 174 0.17 / 711.67 2 2
2 12 1130.28 4 11.03 2001 88 0.26 / 711.76 2 2
3 12 2000.48 42 9.43 3151 1248 1.51 / 713.01 2 2
4 7 1997.80 24 11.18 3238 869 2.38 / 713.87 2 2
5 13 1729.84 48 12.04 2843 1643 4.02 / 715.52 2 2
6 13 483.68 48 13.47 1046 676 4.70 / 716.19 2 6
7 13 30.60 48 14.25 333 228 4.93 / 716.42 2 4
8 8 -0.12 160 14.27 288 658 5.58 / 717.08 2 10
Average= 5.09 (KJ/cycle)

Cycle 139 GMT 10/ 7/2020 10:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 27 14.27 453 175 0.17 / 706.10 2 2
2 12 1141.80 4 10.80 2024 87 0.26 / 706.19 2 2
3 12 2000.04 42 9.53 3141 1257 1.52 / 707.44 2 2
4 7 1997.00 24 11.17 3234 867 2.39 / 708.31 2 2
5 13 1714.64 48 12.09 2803 1627 4.01 / 709.94 2 2
6 13 461.52 48 13.50 1013 656 4.67 / 710.59 2 6
7 13 53.28 48 14.20 372 254 4.92 / 710.85 2 4
8 8 -0.16 160 14.28 284 649 5.57 / 711.50 2 13
Average= 5.08 (KJ/cycle)

Cycle 138 GMT 30/ 6/2020 10:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 27 14.32 449 174 0.17 / 700.27 2 2
2 12 1132.76 4 11.12 2012 89 0.26 / 700.36 2 2
3 12 2002.80 42 9.56 3179 1276 1.54 / 701.63 2 2
4 7 2000.68 24 11.25 3232 873 2.41 / 702.50 2 2
5 13 1875.08 48 11.88 3042 1735 4.15 / 704.24 2 2
6 13 597.28 48 13.32 1230 786 4.93 / 705.03 2 5
7 13 47.96 48 14.21 365 249 5.18 / 705.27 2 4
8 8 -0.16 160 14.29 284 649 5.83 / 705.92 2 11
Average= 5.08 (KJ/cycle)

Cycle 137 GMT 20/ 6/2020 11: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 27 14.30 456 176 0.18 / 694.52 2 2
2 12 1132.60 4 11.17 2000 89 0.27 / 694.61 2 2
3 12 2000.64 42 9.81 3173 1307 1.57 / 695.92 2 2
4 7 1997.80 24 11.24 3226 870 2.44 / 696.79 2 2
5 13 1716.92 48 12.06 2833 1640 4.08 / 698.43 2 2
6 13 579.52 48 13.34 1201 769 4.85 / 699.20 2 6
7 13 46.52 48 14.23 356 243 5.10 / 699.44 2 4
8 8 -0.16 160 14.27 286 653 5.75 / 700.09 2 13
Average= 5.07 (KJ/cycle)

Cycle 136 GMT 10/ 6/2020 10:56: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 27 14.32 439 170 0.17 / 688.79 2 2
2 12 1114.32 4 10.89 1988 87 0.26 / 688.88 2 2
3 12 2001.40 42 9.60 3161 1275 1.53 / 690.15 2 2
4 7 1998.80 24 11.22 3237 872 2.40 / 691.02 2 2
5 13 1864.72 48 11.86 3036 1728 4.13 / 692.75 2 2
6 13 478.32 48 13.47 1054 681 4.81 / 693.43 2 6
7 13 32.56 48 14.26 348 238 5.05 / 693.67 2 4
8 8 -0.04 160 14.28 294 672 5.72 / 694.34 2 9
Average= 5.07 (KJ/cycle)

Cycle 135 GMT 31/ 5/2020 10:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 27 14.27 452 174 0.17 / 683.30 2 2
2 12 1129.08 4 11.06 2008 89 0.26 / 683.39 2 2
3 12 2001.36 42 9.82 3188 1315 1.58 / 684.71 2 2
4 7 1998.64 24 11.16 3222 863 2.44 / 685.57 2 2
5 13 1454.36 48 12.33 2467 1460 3.90 / 687.03 2 2
6 13 530.12 48 13.40 1122 722 4.62 / 687.75 2 6
7 13 16.32 48 14.30 312 214 4.84 / 687.97 2 4
8 8 -0.08 160 14.26 288 657 5.49 / 688.62 2 15
Average= 5.06 (KJ/cycle)

Cycle 134 GMT 21/ 5/2020 10:22: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 27 14.26 458 176 0.18 / 677.99 2 2
2 12 1118.72 4 11.11 2001 89 0.27 / 678.08 2 2
3 12 2000.56 42 9.93 3158 1317 1.58 / 679.39 2 2
4 7 1997.68 24 11.18 3222 865 2.45 / 680.26 2 2
5 13 1578.00 48 12.19 2647 1549 4.00 / 681.81 2 2
6 13 455.08 48 13.50 1011 655 4.65 / 682.46 2 7
7 8 0.00 160 14.27 292 667 5.32 / 683.13 2 8
Average= 5.06 (KJ/cycle)

Cycle 133 GMT 11/ 5/2020 10:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 27 14.26 456 176 0.18 / 672.56 2 2
2 12 1125.64 4 11.16 1993 89 0.26 / 672.65 2 2
3 12 2002.08 42 10.04 3176 1339 1.60 / 673.99 2 2
4 7 1999.24 24 11.15 3242 868 2.47 / 674.86 2 2
5 13 1461.60 48 12.32 2481 1467 3.94 / 676.32 2 3
6 13 386.08 48 13.58 923 602 4.54 / 676.93 2 7
7 13 21.28 48 14.27 324 222 4.76 / 677.15 2 4
8 8 -0.04 160 14.25 291 663 5.43 / 677.81 2 11
Average= 5.06 (KJ/cycle)

Cycle 132 GMT 1/ 5/2020 10: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 27 14.23 464 178 0.18 / 667.38 2 2
2 12 1098.80 4 11.27 1959 88 0.27 / 667.47 2 2
3 12 2002.00 42 10.11 3157 1341 1.61 / 668.81 2 2
4 7 1999.56 24 11.20 3237 870 2.48 / 669.68 2 2
5 13 1458.48 48 12.33 2472 1463 3.94 / 671.14 2 2
6 13 356.64 48 13.63 875 572 4.51 / 671.72 2 7
7 8 0.00 160 14.24 294 670 5.18 / 672.39 2 7
Average= 5.06 (KJ/cycle)

Cycle 131 GMT 21/ 4/2020 9:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 27 14.28 439 169 0.17 / 661.74 2 2
2 12 1113.36 4 11.25 1971 89 0.26 / 661.83 2 2
3 12 2000.80 42 10.02 3196 1345 1.60 / 663.18 2 2
4 7 1997.84 24 11.15 3227 864 2.47 / 664.04 2 2
5 13 1862.08 48 11.84 3060 1739 4.21 / 665.78 2 2
6 13 539.08 48 13.39 1143 735 4.94 / 666.52 2 6
7 8 -0.16 160 14.22 302 687 5.63 / 667.20 2 10
Average= 5.05 (KJ/cycle)

Cycle 130 GMT 11/ 4/2020 9:46: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 27 14.30 447 173 0.17 / 656.45 2 2
2 12 1105.44 4 11.30 1950 88 0.26 / 656.54 2 2
3 12 1999.40 42 10.10 3202 1358 1.62 / 657.90 2 2
4 7 1996.16 24 11.13 3242 866 2.49 / 658.76 2 2
5 13 1440.56 48 12.35 2449 1452 3.94 / 660.22 2 2
6 13 508.32 48 13.44 1083 699 4.64 / 660.91 2 6
7 8 -0.04 160 14.25 290 661 5.30 / 661.58 2 8
Average= 5.05 (KJ/cycle)

Cycle 129 GMT 1/ 4/2020 9:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 27 14.31 421 163 0.16 / 651.04 2 2
2 12 1109.40 4 11.46 1971 90 0.25 / 651.13 2 2
3 12 2002.40 42 10.28 3189 1377 1.63 / 652.51 2 2
4 7 1999.60 24 11.18 3231 867 2.50 / 653.38 2 2
5 13 1592.24 48 12.19 2653 1552 4.05 / 654.93 2 2
6 13 500.20 48 13.45 1071 691 4.74 / 655.62 2 6
7 8 0.04 160 14.26 289 659 5.40 / 656.28 2 7
Average= 5.05 (KJ/cycle)

Cycle 128 GMT 22/ 3/2020 9:34: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 27 14.30 439 169 0.17 / 645.65 2 2
2 12 1115.36 4 11.35 1976 90 0.26 / 645.74 2 2
3 12 2000.96 42 10.17 3195 1365 1.62 / 647.10 2 2
4 7 1997.88 24 11.15 3239 867 2.49 / 647.97 2 2
5 13 1712.88 48 12.05 2823 1633 4.12 / 649.60 2 2
6 13 417.40 48 13.55 947 616 4.74 / 650.22 2 7
7 8 -0.04 160 14.26 289 659 5.40 / 650.88 2 8
Average= 5.05 (KJ/cycle)

Cycle 127 GMT 12/ 3/2020 9:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 27 14.31 434 168 0.17 / 640.35 2 2
2 12 1114.32 4 11.40 1985 91 0.26 / 640.44 2 2
3 12 1999.24 42 10.16 3228 1377 1.64 / 641.82 2 2
4 7 1996.28 24 11.18 3222 865 2.50 / 642.68 2 2
5 13 1443.72 48 12.34 2453 1453 3.95 / 644.14 2 2
6 13 486.48 48 13.46 1051 679 4.63 / 644.82 2 7
7 8 -0.04 160 14.25 291 663 5.30 / 645.48 2 11
Average= 5.04 (KJ/cycle)

Cycle 126 GMT 2/ 3/2020 9:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 27 14.29 453 175 0.17 / 635.16 2 2
2 12 1117.52 4 11.38 1990 91 0.27 / 635.25 2 2
3 12 1999.64 42 10.17 3225 1378 1.64 / 636.62 2 2
4 7 1996.72 24 11.13 3243 866 2.51 / 637.49 2 2
5 13 1454.24 48 12.35 2444 1449 3.96 / 638.94 2 3
6 13 357.84 48 13.62 876 573 4.53 / 639.51 2 8
7 8 0.00 160 14.23 295 672 5.20 / 640.18 2 12
Average= 5.04 (KJ/cycle)

Cycle 125 GMT 21/ 2/2020 8:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 27 14.25 447 172 0.17 / 629.79 2 2
2 12 1123.12 4 11.39 2010 92 0.26 / 629.88 2 2
3 12 2003.60 42 10.36 3186 1386 1.65 / 631.27 2 2
4 7 2000.76 24 11.14 3236 865 2.52 / 632.13 2 2
5 13 1591.84 48 12.19 2631 1539 4.05 / 633.67 2 2
6 13 429.24 48 13.53 976 634 4.69 / 634.31 2 7
7 8 0.08 160 14.24 297 677 5.37 / 634.98 2 9
Average= 5.04 (KJ/cycle)

Cycle 124 GMT 11/ 2/2020 8:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 27 14.31 425 164 0.16 / 624.48 2 2
2 12 1126.64 4 11.46 1997 92 0.26 / 624.57 2 2
3 12 2001.76 42 10.37 3192 1390 1.65 / 625.96 2 2
4 7 1998.80 24 11.20 3202 861 2.51 / 626.82 2 2
5 13 1593.32 48 12.17 2658 1553 4.06 / 628.37 2 2
6 13 377.92 48 13.60 899 587 4.65 / 628.96 2 7
7 8 0.08 160 14.25 289 659 5.31 / 629.62 2 9
Average= 5.04 (KJ/cycle)

Cycle 123 GMT 1/ 2/2020 8: 4: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 27 14.30 441 170 0.17 / 619.27 2 2
2 12 1117.00 4 11.56 1976 91 0.26 / 619.36 2 2
3 12 2002.52 42 10.38 3197 1394 1.66 / 620.76 2 2
4 7 1999.76 24 11.08 3226 858 2.51 / 621.61 2 2
5 13 1458.92 48 12.30 2469 1458 3.97 / 623.07 2 2
6 13 369.28 48 13.61 892 583 4.55 / 623.65 2 8
7 8 -0.04 160 14.24 289 658 5.21 / 624.31 2 6
Average= 5.03 (KJ/cycle)

Cycle 122 GMT 22/ 1/2020 8: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 27 14.27 442 170 0.17 / 614.09 2 2
2 12 1131.96 4 11.53 2021 93 0.26 / 614.18 2 2
3 12 1999.60 42 10.44 3186 1397 1.66 / 615.58 2 2
4 7 1996.64 24 11.12 3227 861 2.52 / 616.44 2 2
5 13 1429.04 48 12.33 2438 1443 3.96 / 617.88 2 2
6 13 329.64 48 13.67 830 545 4.51 / 618.42 2 7
7 8 0.00 160 14.22 297 676 5.18 / 619.10 2 10
Average= 5.03 (KJ/cycle)

Cycle 121 GMT 12/ 1/2020 7:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 27 14.30 444 171 0.17 / 608.77 2 2
2 12 1114.52 4 11.60 1980 92 0.26 / 608.86 2 2
3 12 2001.80 42 10.42 3186 1394 1.66 / 610.25 2 2
4 7 1998.60 24 11.11 3225 860 2.52 / 611.11 2 2
5 13 1451.40 48 12.33 2451 1451 3.97 / 612.56 2 2
6 13 478.00 48 13.47 1042 674 4.64 / 613.24 2 7
7 8 -0.16 160 14.23 297 676 5.32 / 613.91 2 6
Average= 5.03 (KJ/cycle)

Cycle 120 GMT 2/ 1/2020 7:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 27 14.30 427 165 0.16 / 603.39 2 2
2 12 1126.44 4 11.56 2002 93 0.26 / 603.49 2 2
3 12 1997.08 42 10.42 3191 1397 1.65 / 604.88 2 2
4 7 1993.64 24 11.12 3203 855 2.51 / 605.74 2 2
5 13 1566.12 48 12.18 2636 1541 4.05 / 607.28 2 2
6 13 437.24 48 13.50 991 642 4.69 / 607.92 2 7
7 8 0.04 160 14.22 297 676 5.37 / 608.60 2 10
Average= 5.03 (KJ/cycle)

Cycle 119 GMT 23/12/2019 6:38:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 27 14.28 441 170 0.17 / 598.03 2 2
2 12 1121.88 4 11.69 1987 93 0.26 / 598.12 2 2
3 12 2000.48 42 10.43 3219 1410 1.67 / 599.53 2 2
4 7 1997.44 24 11.10 3240 863 2.54 / 600.39 2 2
5 13 1558.16 48 12.19 2607 1525 4.06 / 601.92 2 2
6 13 442.88 48 13.51 982 637 4.70 / 602.56 2 7
7 8 -0.20 160 14.21 296 673 5.37 / 603.23 2 8
Average= 5.03 (KJ/cycle)

Cycle 118 GMT 13/12/2019 6:30:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 27 14.26 442 170 0.17 / 592.85 2 2
2 12 1128.16 4 11.71 2005 94 0.26 / 592.94 2 2
3 12 2003.00 42 10.48 3215 1415 1.68 / 594.35 2 2
4 7 1999.88 24 11.10 3242 864 2.54 / 595.22 2 2
5 13 1432.12 48 12.34 2421 1434 3.98 / 596.65 2 3
6 13 338.00 48 13.66 834 547 4.52 / 597.20 2 8
7 8 0.08 160 14.24 289 658 5.18 / 597.86 2 7
Average= 5.02 (KJ/cycle)

Cycle 117 GMT 3/12/2019 5:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 27 14.29 427 165 0.16 / 587.48 2 2
2 12 1116.76 4 11.81 1983 94 0.26 / 587.57 2 2
3 12 2001.08 42 10.48 3199 1408 1.67 / 588.98 2 2
4 7 1997.96 24 11.08 3218 856 2.52 / 589.84 2 2
5 13 1594.20 48 12.18 2636 1541 4.06 / 591.38 2 2
6 13 439.24 48 13.52 976 633 4.70 / 592.01 2 7
7 8 -0.04 160 14.22 291 662 5.36 / 592.68 2 17
Average= 5.02 (KJ/cycle)

Cycle 116 GMT 23/11/2019 5:29: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 27 14.29 430 166 0.17 / 582.29 2 2
2 12 1110.76 4 11.81 1977 93 0.26 / 582.38 2 2
3 12 2003.32 42 10.55 3221 1427 1.69 / 583.81 2 2
4 7 2000.76 24 11.16 3216 861 2.55 / 584.67 2 2
5 13 1452.44 48 12.32 2460 1455 4.00 / 586.13 2 2
6 13 343.24 48 13.65 833 546 4.55 / 586.67 2 7
7 8 -0.04 160 14.24 283 645 5.19 / 587.32 2 9
Average= 5.02 (KJ/cycle)

Cycle 115 GMT 13/11/2019 5:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 27 14.32 419 162 0.16 / 576.83 2 2
2 12 1115.76 4 11.77 1993 94 0.26 / 576.93 2 2
3 12 2004.00 42 10.46 3204 1408 1.66 / 578.34 2 2
4 7 2000.92 24 11.11 3241 864 2.53 / 579.20 2 2
5 13 1730.80 48 12.02 2849 1644 4.17 / 580.84 2 2
6 13 414.96 48 13.54 947 615 4.79 / 581.46 2 7
7 8 -0.20 160 14.22 292 664 5.45 / 582.12 2 10
Average= 5.02 (KJ/cycle)

Cycle 114 GMT 3/11/2019 4:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 27 14.29 434 167 0.17 / 571.37 2 2
2 12 1124.80 4 11.76 1997 94 0.26 / 571.47 2 2
3 12 1999.08 42 10.55 3203 1419 1.68 / 572.89 2 2
4 7 1995.64 24 11.13 3233 864 2.54 / 573.75 2 2
5 13 1571.60 48 12.22 2599 1524 4.07 / 575.27 2 2
6 13 563.44 48 13.36 1156 741 4.81 / 576.02 2 6
7 8 -0.08 160 14.24 288 656 5.47 / 576.67 2 5
Average= 5.01 (KJ/cycle)

Cycle 113 GMT 24/10/2019 4:14: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 27 14.31 435 168 0.17 / 566.04 2 2
2 12 1113.36 4 11.77 1980 93 0.26 / 566.13 2 2
3 12 2000.80 42 10.55 3211 1423 1.68 / 567.55 2 2
4 7 1997.76 24 11.12 3215 858 2.54 / 568.41 2 2
5 13 1563.04 48 12.21 2608 1528 4.07 / 569.94 2 2
6 13 410.92 48 13.56 935 609 4.68 / 570.55 2 7
7 8 -0.12 160 14.23 289 658 5.34 / 571.21 2 9
Average= 5.01 (KJ/cycle)

Cycle 112 GMT 14/10/2019 4: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 27 14.33 438 169 0.17 / 560.79 2 2
2 12 1122.56 4 11.89 1998 95 0.26 / 560.88 2 2
3 12 2002.76 42 10.58 3222 1432 1.70 / 562.31 2 2
4 7 1999.64 24 11.15 3221 862 2.56 / 563.18 2 2
5 13 1457.12 48 12.34 2450 1451 4.01 / 564.63 2 2
6 13 366.60 48 13.62 889 581 4.59 / 565.21 2 8
7 8 -0.08 160 14.24 290 661 5.25 / 565.87 2 11
Average= 5.01 (KJ/cycle)

Cycle 111 GMT 4/10/2019 3:14: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 27 14.33 451 174 0.17 / 555.51 2 2
2 12 1104.84 4 11.83 1982 94 0.27 / 555.60 2 2
3 12 2002.88 42 10.60 3203 1426 1.69 / 557.03 2 2
4 7 2000.00 24 11.13 3227 862 2.56 / 557.89 2 2
5 13 1593.32 48 12.21 2627 1540 4.10 / 559.43 2 2
6 13 330.40 48 13.69 823 541 4.64 / 559.97 2 7
7 8 -0.12 160 14.26 283 646 5.28 / 560.62 2 8
Average= 5.01 (KJ/cycle)

Cycle 110 GMT 24/ 9/2019 2:34: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 27 14.28 431 166 0.17 / 550.12 2 2
2 12 1121.16 4 11.87 1977 94 0.26 / 550.22 2 2
3 12 1999.00 42 10.66 3197 1431 1.69 / 551.65 2 2
4 7 1995.64 24 11.15 3217 861 2.55 / 552.51 2 2
5 13 1577.68 48 12.22 2639 1548 4.10 / 554.06 2 2
6 13 421.72 48 13.55 960 624 4.72 / 554.68 2 7
7 8 -0.04 160 14.27 287 655 5.38 / 555.34 2 9
Average= 5.00 (KJ/cycle)

Cycle 109 GMT 14/ 9/2019 2:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 26 14.34 449 167 0.17 / 544.37 2 2
2 3 1025.40 1 11.13 1884 21 0.19 / 544.39 2 2
3 12 1131.68 4 11.83 2012 95 0.28 / 544.48 2 2
4 12 1999.08 42 10.67 3203 1435 1.72 / 545.92 2 2
5 7 1995.80 24 11.21 3205 862 2.58 / 546.78 2 2
6 13 1556.00 48 12.25 2591 1524 4.10 / 548.30 2 2
7 13 550.44 48 13.40 1150 740 4.84 / 549.04 2 7
8 13 34.80 48 14.22 355 242 5.09 / 549.29 2 6
9 8 -0.24 160 14.21 294 668 5.76 / 549.96 2 17
Average= 5.00 (KJ/cycle)

Cycle 108 GMT 4/ 9/2019 2:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 27 14.36 424 164 0.16 / 538.62 2 2
2 12 1114.28 4 11.90 1994 95 0.26 / 538.71 2 2
3 12 2002.84 42 10.69 3207 1440 1.70 / 540.15 2 2
4 7 1999.60 24 11.21 3213 864 2.56 / 541.02 2 2
5 13 1554.72 48 12.25 2626 1544 4.11 / 542.56 2 2
6 13 540.12 48 13.41 1140 734 4.84 / 543.30 2 7
7 13 12.92 48 14.26 321 220 5.06 / 543.52 2 6
8 8 -0.28 160 14.19 301 683 5.74 / 544.20 2 15
Average= 4.99 (KJ/cycle)

Cycle 107 GMT 25/ 8/2019 2: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 27 14.37 421 163 0.16 / 532.65 2 2
2 12 1134.52 4 11.96 2020 97 0.26 / 532.74 2 2
3 12 2006.32 42 10.71 3219 1448 1.71 / 534.19 2 2
4 7 2003.40 24 11.22 3234 871 2.58 / 535.06 2 2
5 13 1858.20 48 11.90 3016 1723 4.30 / 536.79 2 2
6 13 624.20 48 13.30 1252 799 5.10 / 537.59 2 6
7 13 25.72 48 14.28 325 223 5.32 / 537.81 2 5
8 8 -0.08 160 14.25 284 648 5.97 / 538.46 2 11
Average= 4.99 (KJ/cycle)

Cycle 106 GMT 15/ 8/2019 1:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 27 14.36 419 162 0.16 / 526.78 2 2
2 12 1128.64 4 11.89 2020 96 0.26 / 526.87 2 2
3 12 2002.36 42 10.68 3208 1439 1.70 / 528.31 2 2
4 7 1999.64 24 11.18 3235 868 2.57 / 529.18 2 2
5 13 1858.48 48 11.91 3020 1726 4.29 / 530.91 2 2
6 13 516.72 48 13.45 1092 705 5.00 / 531.61 2 7
7 13 27.92 48 14.27 327 224 5.22 / 531.84 2 5
8 8 -0.32 160 14.24 285 649 5.87 / 532.48 2 13
Average= 4.98 (KJ/cycle)

Cycle 105 GMT 5/ 8/2019 1:22: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 27 14.33 426 165 0.16 / 520.80 2 2
2 12 1127.44 4 11.98 1990 95 0.26 / 520.90 2 2
3 12 2002.32 42 10.72 3217 1448 1.71 / 522.34 2 2
4 7 1999.40 24 11.21 3218 866 2.57 / 523.21 2 2
5 13 1852.48 48 11.94 2989 1713 4.29 / 524.92 2 2
6 13 639.92 48 13.30 1275 814 5.10 / 525.74 2 6
7 13 25.60 48 14.28 325 223 5.32 / 525.96 2 5
8 8 0.00 160 14.24 287 654 5.98 / 526.61 2 13
Average= 4.97 (KJ/cycle)

Cycle 104 GMT 26/ 7/2019 1:14: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 27 14.35 421 163 0.16 / 515.45 2 2
2 12 1117.56 4 11.96 1985 95 0.26 / 515.55 2 2
3 12 2002.04 41 10.75 3207 1413 1.67 / 516.96 2 2
4 7 1998.80 24 11.21 3217 866 2.54 / 517.83 2 2
5 13 1560.28 48 12.26 2616 1539 4.08 / 519.37 2 2
6 13 411.32 48 13.59 946 617 4.69 / 519.98 2 8
7 8 -0.04 160 14.26 286 653 5.35 / 520.64 2 11
Average= 4.96 (KJ/cycle)

Cycle 103 GMT 16/ 7/2019 0:59: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 27 14.33 425 164 0.16 / 509.92 2 2
2 12 1116.20 4 11.85 1988 94 0.26 / 510.02 2 2
3 12 2000.16 41 10.76 3213 1417 1.68 / 511.43 2 2
4 7 1997.04 24 11.25 3220 869 2.55 / 512.30 2 2
5 13 1561.72 48 12.28 2583 1523 4.07 / 513.82 2 2
6 13 412.92 48 13.59 938 612 4.68 / 514.44 2 7
7 13 17.64 48 14.30 308 211 4.89 / 514.65 2 5
8 8 -0.20 160 14.22 282 642 5.53 / 515.29 2 12
Average= 4.95 (KJ/cycle)

Cycle 102 GMT 6/ 7/2019 1: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 26 14.34 426 159 0.16 / 504.44 2 2
2 12 1127.36 4 11.90 2004 95 0.25 / 504.53 2 2
3 12 1998.84 41 10.86 3216 1432 1.69 / 505.97 2 2
4 7 1995.60 24 11.34 3210 874 2.56 / 506.84 2 2
5 13 1567.44 48 12.28 2617 1543 4.10 / 508.38 2 2
6 13 533.16 48 13.45 1115 720 4.82 / 509.10 2 6
7 8 -0.08 160 14.27 287 655 5.48 / 509.76 2 10
Average= 4.95 (KJ/cycle)

Cycle 101 GMT 26/ 6/2019 1:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 26 14.37 433 162 0.16 / 498.92 2 2
2 12 1138.00 4 12.00 2023 97 0.26 / 499.02 2 2
3 12 1999.76 41 10.82 3221 1429 1.69 / 500.45 2 2
4 7 1996.56 24 11.28 3223 873 2.56 / 501.32 2 2
5 13 1703.04 48 12.15 2785 1624 4.18 / 502.95 2 2
6 13 506.76 48 13.49 1062 688 4.87 / 503.63 2 6
7 8 -0.08 160 14.27 283 646 5.52 / 504.28 2 6
Average= 4.94 (KJ/cycle)

Cycle 100 GMT 16/ 6/2019 1:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 26 14.33 424 158 0.16 / 492.99 2 2
2 12 1141.40 4 11.92 2015 96 0.25 / 493.09 2 2
3 12 1999.00 41 10.85 3215 1430 1.68 / 494.52 2 2
4 7 1995.84 24 11.27 3217 870 2.55 / 495.39 2 2
5 13 1706.56 48 12.14 2805 1635 4.19 / 497.02 2 2
6 13 683.28 48 13.27 1342 855 5.04 / 497.88 2 6
7 13 26.64 48 14.26 333 228 5.27 / 498.10 2 6
8 8 -0.12 160 14.22 289 658 5.93 / 498.76 2 14
Average= 4.94 (KJ/cycle)

Cycle 99 GMT 6/ 6/2019 1:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 26 14.34 437 163 0.16 / 487.43 2 2
2 12 1140.72 4 11.98 2041 98 0.26 / 487.53 2 2
3 12 1994.04 41 10.91 3202 1432 1.69 / 488.96 2 2
4 7 1990.60 24 11.35 3215 876 2.57 / 489.84 2 2
5 13 1701.12 48 12.15 2806 1636 4.21 / 491.48 2 2
6 13 511.92 48 13.47 1081 699 4.90 / 492.18 2 7
7 8 -0.12 160 14.25 288 657 5.56 / 492.83 2 10
Average= 4.93 (KJ/cycle)

Cycle 98 GMT 27/ 5/2019 0:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 27 14.37 416 161 0.16 / 481.84 2 2
2 12 1111.04 4 12.20 1975 96 0.26 / 481.94 2 2
3 12 2000.44 41 11.00 3237 1460 1.72 / 483.40 2 2
4 7 1997.28 24 11.32 3211 872 2.59 / 484.27 2 2
5 13 1706.76 48 12.13 2804 1633 4.22 / 485.91 2 2
6 13 505.36 48 13.47 1079 698 4.92 / 486.60 2 7
7 8 -0.08 160 14.24 293 668 5.59 / 487.27 2 8
Average= 4.92 (KJ/cycle)

Cycle 97 GMT 17/ 5/2019 0:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 27 14.33 435 168 0.17 / 476.00 2 2
2 12 1111.48 4 12.01 1986 95 0.26 / 476.10 2 2
3 12 2000.28 41 10.89 3226 1440 1.70 / 477.54 2 2
4 7 1997.52 24 11.32 3192 867 2.57 / 478.40 2 2
5 13 1850.56 48 11.96 3003 1724 4.30 / 480.13 2 2
6 13 493.32 48 13.50 1050 680 4.98 / 480.81 2 7
7 13 23.36 48 14.29 325 223 5.20 / 481.03 2 6
8 8 -0.08 160 14.24 286 652 5.85 / 481.68 2 11
Average= 4.92 (KJ/cycle)

Cycle 96 GMT 7/ 5/2019 1: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 27 14.32 458 177 0.18 / 470.41 2 2
2 12 1111.52 4 12.01 1980 95 0.27 / 470.50 2 2
3 12 1999.76 41 10.91 3208 1435 1.71 / 471.94 2 2
4 7 1996.56 24 11.32 3231 878 2.58 / 472.82 2 2
5 13 1698.64 48 12.15 2805 1636 4.22 / 474.45 2 2
6 13 519.28 48 13.46 1105 714 4.93 / 475.16 2 7
7 8 0.00 160 14.25 293 668 5.60 / 475.83 2 11
Average= 4.91 (KJ/cycle)

Cycle 95 GMT 27/ 4/2019 0:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 26 14.36 429 160 0.16 / 464.83 2 2
2 12 1129.64 4 12.05 2007 97 0.26 / 464.92 2 2
3 12 1990.56 41 10.92 3189 1428 1.68 / 466.35 2 2
4 7 1987.00 24 11.36 3214 876 2.56 / 467.23 2 2
5 13 1691.20 48 12.19 2791 1633 4.19 / 468.86 2 2
6 13 507.44 48 13.48 1085 702 4.90 / 469.56 2 7
7 8 -0.08 160 14.27 292 667 5.56 / 470.23 2 11
Average= 4.90 (KJ/cycle)

Cycle 94 GMT 17/ 4/2019 0:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 26 14.37 427 160 0.16 / 459.32 2 2
2 12 1109.52 4 11.99 1994 96 0.26 / 459.41 2 2
3 12 2000.88 41 10.99 3211 1447 1.70 / 460.86 2 2
4 7 1997.76 24 11.40 3201 876 2.58 / 461.74 2 2
5 13 1548.32 48 12.34 2601 1541 4.12 / 463.28 2 2
6 13 527.64 48 13.46 1123 726 4.84 / 464.00 2 6
7 8 0.08 160 14.27 291 664 5.51 / 464.67 2 10
Average= 4.89 (KJ/cycle)

Cycle 93 GMT 6/ 4/2019 23:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 26 14.34 460 172 0.17 / 453.91 2 2
2 12 1126.36 4 12.03 2014 97 0.27 / 454.01 2 2
3 12 1999.04 41 11.02 3218 1454 1.72 / 455.47 2 2
4 7 1995.88 24 11.39 3236 885 2.61 / 456.35 2 2
5 13 1545.80 48 12.34 2599 1539 4.15 / 457.89 2 2
6 13 395.04 48 13.64 928 608 4.75 / 458.50 2 8
7 8 -0.08 160 14.26 290 662 5.42 / 459.16 2 10
Average= 4.88 (KJ/cycle)

Cycle 92 GMT 27/ 3/2019 23:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 26 14.34 453 169 0.17 / 448.25 2 2
2 12 1110.28 4 12.04 1987 96 0.26 / 448.34 2 2
3 12 2000.52 41 11.05 3202 1451 1.72 / 449.79 2 2
4 7 1997.32 24 11.39 3243 887 2.60 / 450.68 2 2
5 13 1716.32 48 12.18 2854 1669 4.27 / 452.35 2 2
6 13 506.36 48 13.49 1099 712 4.98 / 453.06 2 7
7 8 -0.08 160 14.27 299 683 5.66 / 453.74 2 7
Average= 4.88 (KJ/cycle)

Cycle 91 GMT 17/ 3/2019 23:14: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 26 14.38 435 163 0.16 / 442.62 2 2
2 12 1123.40 4 12.02 2014 97 0.26 / 442.72 2 2
3 12 1998.88 41 11.12 3215 1466 1.73 / 444.18 2 2
4 7 1995.64 24 11.46 3200 880 2.61 / 445.06 2 2
5 13 1701.04 48 12.21 2805 1644 4.25 / 446.71 2 2
6 13 496.68 48 13.50 1079 699 4.95 / 447.41 2 7
7 8 0.00 160 14.26 295 673 5.62 / 448.08 2 6
Average= 4.87 (KJ/cycle)

Cycle 90 GMT 7/ 3/2019 23:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 26 14.33 436 162 0.16 / 436.98 2 2
2 12 1122.48 4 12.12 2000 97 0.26 / 437.07 2 2
3 12 1999.24 41 11.14 3219 1470 1.73 / 438.55 2 2
4 7 1996.04 24 11.43 3232 887 2.62 / 439.43 2 2
5 13 1708.20 48 12.20 2815 1648 4.26 / 441.08 2 2
6 13 516.56 48 13.50 1096 710 4.97 / 441.79 2 7
7 8 -0.08 160 14.27 292 667 5.64 / 442.46 2 12
Average= 4.86 (KJ/cycle)

Cycle 89 GMT 25/ 2/2019 22:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 27 14.37 429 166 0.17 / 431.10 2 2
2 12 1100.84 4 12.08 1987 96 0.26 / 431.20 2 2
3 12 2002.20 41 11.12 3226 1471 1.73 / 432.67 2 2
4 7 1999.28 24 11.49 3227 890 2.62 / 433.56 2 2
5 13 1854.00 48 12.03 3038 1754 4.38 / 435.31 2 2
6 13 641.52 48 13.33 1285 822 5.20 / 436.14 2 6
7 8 0.00 160 14.26 298 680 5.88 / 436.82 2 9
Average= 4.85 (KJ/cycle)

Cycle 88 GMT 15/ 2/2019 22:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 26 14.34 438 163 0.16 / 425.45 2 2
2 12 1125.24 4 12.08 2019 98 0.26 / 425.55 2 2
3 12 2004.88 41 11.08 3232 1468 1.73 / 427.01 2 2
4 7 2001.76 24 11.48 3241 893 2.62 / 427.91 2 2
5 13 1709.44 48 12.21 2808 1646 4.27 / 429.55 2 2
6 13 511.72 48 13.50 1088 705 4.97 / 430.26 2 7
7 8 0.04 160 14.24 298 679 5.65 / 430.94 2 8
Average= 4.84 (KJ/cycle)

Cycle 87 GMT 5/ 2/2019 21:40: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 26 14.36 431 161 0.16 / 420.02 2 2
2 12 1117.96 4 12.14 1996 97 0.26 / 420.12 2 2
3 12 2000.68 41 11.12 3217 1467 1.72 / 421.58 2 2
4 7 1997.68 24 11.49 3218 887 2.61 / 422.47 2 2
5 13 1560.92 48 12.36 2611 1549 4.16 / 424.02 2 3
6 13 388.36 48 13.65 916 600 4.76 / 424.62 2 7
7 8 -0.08 160 14.25 291 663 5.42 / 425.28 2 7
Average= 4.83 (KJ/cycle)

Cycle 86 GMT 26/ 1/2019 21:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 26 14.38 427 160 0.16 / 414.56 2 2
2 12 1119.16 4 12.17 2013 98 0.26 / 414.66 2 2
3 12 1991.24 41 11.15 3207 1466 1.72 / 416.12 2 2
4 7 1987.60 24 11.53 3199 885 2.61 / 417.01 2 2
5 13 1517.84 48 12.41 2557 1523 4.13 / 418.53 2 3
6 13 477.84 48 13.54 1033 671 4.80 / 419.20 2 8
7 8 0.04 160 14.26 288 657 5.46 / 419.86 2 8
Average= 4.83 (KJ/cycle)

Cycle 85 GMT 16/ 1/2019 21: 9: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 27 14.37 440 171 0.17 / 409.14 2 2
2 12 1117.44 4 12.18 2002 98 0.27 / 409.23 2 2
3 12 2000.08 41 11.19 3218 1476 1.74 / 410.71 2 2
4 7 1996.88 24 11.51 3242 896 2.64 / 411.61 2 2
5 13 1553.28 48 12.40 2591 1542 4.18 / 413.15 2 2
6 13 376.80 48 13.68 899 590 4.77 / 413.74 2 8
7 8 -0.12 160 14.25 290 661 5.43 / 414.40 2 9
Average= 4.82 (KJ/cycle)

Cycle 84 GMT 6/ 1/2019 20:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 26 14.35 452 169 0.17 / 403.58 2 2
2 12 1125.36 4 12.08 1999 97 0.27 / 403.67 2 2
3 12 2000.20 41 11.17 3212 1471 1.74 / 405.15 2 2
4 7 1997.20 24 11.54 3239 897 2.63 / 406.04 2 2
5 13 1543.48 48 12.41 2595 1546 4.18 / 407.59 2 2
6 13 505.92 48 13.52 1086 705 4.88 / 408.29 2 8
7 8 -0.04 160 14.28 294 672 5.56 / 408.97 2 10
Average= 4.81 (KJ/cycle)

Cycle 83 GMT 27/12/2018 21: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 26 14.37 473 177 0.18 / 398.20 2 2
2 12 1120.96 4 11.97 2007 96 0.27 / 398.30 2 2
3 12 2000.28 41 11.22 3207 1475 1.75 / 399.77 2 2
4 7 1997.36 24 11.60 3235 901 2.65 / 400.67 2 2
5 13 1408.56 48 12.57 2401 1449 4.10 / 402.12 2 3
6 13 412.80 48 13.65 954 625 4.72 / 402.74 2 8
7 8 -0.12 160 14.28 291 665 5.39 / 403.41 2 10
Average= 4.80 (KJ/cycle)

Cycle 82 GMT 17/12/2018 20:59: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 26 14.36 436 163 0.16 / 392.54 2 2
2 12 1118.64 4 12.04 2014 97 0.26 / 392.64 2 2
3 12 1999.20 41 11.26 3212 1483 1.74 / 394.12 2 2
4 7 1995.92 24 11.63 3225 900 2.64 / 395.02 2 2
5 13 1691.36 48 12.30 2797 1651 4.29 / 396.67 2 2
6 13 484.92 48 13.55 1053 685 4.98 / 397.36 2 7
7 8 -0.04 160 14.30 291 666 5.64 / 398.02 2 10
Average= 4.80 (KJ/cycle)

Cycle 81 GMT 7/12/2018 21: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 26 14.39 447 167 0.17 / 386.66 2 2
2 12 1128.28 4 11.95 2029 97 0.26 / 386.76 2 2
3 12 1992.00 41 11.17 3187 1460 1.72 / 388.22 2 2
4 7 1988.76 24 11.60 3227 898 2.62 / 389.12 2 2
5 13 1687.76 48 12.30 2802 1654 4.28 / 390.77 2 2
6 13 507.72 48 13.54 1085 705 4.98 / 391.48 2 7
7 13 28.52 48 14.32 336 231 5.21 / 391.71 2 6
8 8 0.00 160 14.25 294 670 5.88 / 392.38 2 15
Average= 4.79 (KJ/cycle)

Cycle 80 GMT 27/11/2018 20:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 26 14.35 441 165 0.16 / 381.09 2 2
2 12 1115.36 4 11.90 2007 96 0.26 / 381.18 2 2
3 12 1998.92 41 11.14 3194 1459 1.72 / 382.64 2 2
4 7 1995.48 24 11.56 3242 899 2.62 / 383.54 2 2
5 13 1548.68 48 12.45 2626 1569 4.19 / 385.11 2 2
6 13 520.24 48 13.53 1106 718 4.91 / 385.83 2 7
7 8 0.08 160 14.30 291 666 5.57 / 386.49 2 14
Average= 4.77 (KJ/cycle)

Cycle 79 GMT 17/11/2018 19:47:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 26 14.40 437 164 0.16 / 375.71 2 2
2 12 1109.68 4 11.35 1988 90 0.25 / 375.80 2 2
3 12 1999.72 41 11.21 3206 1474 1.73 / 377.28 2 2
4 7 1996.88 24 11.62 3228 900 2.63 / 378.18 2 2
5 13 1417.04 48 12.60 2420 1464 4.09 / 379.64 2 3
6 13 415.08 48 13.68 941 618 4.71 / 380.26 2 8
7 8 -0.16 160 14.27 291 664 5.37 / 380.92 2 8
Average= 4.76 (KJ/cycle)

Cycle 78 GMT 7/11/2018 19:55:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 26 14.40 431 161 0.16 / 370.08 2 2
2 12 1117.28 4 11.30 1998 90 0.25 / 370.17 2 2
3 12 1999.12 41 11.10 3181 1448 1.70 / 371.62 2 2
4 7 1995.92 24 11.59 3234 900 2.60 / 372.52 2 2
5 13 1700.96 48 12.33 2815 1666 4.26 / 374.19 2 3
6 13 503.32 48 13.56 1079 702 4.97 / 374.89 2 7
7 8 -0.08 160 14.29 289 661 5.63 / 375.55 2 13
Average= 4.75 (KJ/cycle)

Cycle 77 GMT 28/10/2018 19:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 27 14.38 429 167 0.17 / 364.55 2 2
2 12 1118.16 4 11.13 1969 88 0.25 / 364.64 2 2
3 12 2007.12 41 11.08 3190 1449 1.70 / 366.09 2 2
4 7 2004.20 24 11.59 3255 905 2.61 / 366.99 2 2
5 13 1568.92 48 12.47 2632 1575 4.18 / 368.57 2 3
6 13 493.72 48 13.58 1060 691 4.88 / 369.26 2 7
7 8 -0.12 160 14.29 289 661 5.54 / 369.92 2 10
Average= 4.74 (KJ/cycle)

Cycle 76 GMT 18/10/2018 19:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 27 14.41 443 172 0.17 / 359.14 2 2
2 12 1128.52 4 10.84 1998 87 0.26 / 359.23 2 2
3 12 1998.92 41 11.10 3180 1447 1.71 / 360.68 2 2
4 7 1995.44 24 11.64 3215 898 2.60 / 361.58 2 2
5 13 1542.68 48 12.51 2599 1561 4.16 / 363.14 2 3
6 13 369.28 48 13.75 887 585 4.75 / 363.72 2 8
7 8 -0.12 160 14.28 290 663 5.41 / 364.39 2 10
Average= 4.73 (KJ/cycle)

Cycle 75 GMT 8/10/2018 19:29: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 26 14.39 443 166 0.17 / 353.73 2 2
2 12 1136.52 4 10.73 2019 87 0.25 / 353.82 2 2
3 12 2001.40 41 11.06 3198 1450 1.70 / 355.27 2 2
4 7 1998.28 24 11.60 3236 901 2.60 / 356.17 2 2
5 13 1528.20 48 12.54 2561 1542 4.14 / 357.71 2 3
6 13 371.60 48 13.75 900 594 4.74 / 358.30 2 8
7 8 -0.08 160 14.29 292 668 5.41 / 358.97 2 11
Average= 4.72 (KJ/cycle)

Cycle 74 GMT 28/ 9/2018 19:39:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 26 14.45 426 160 0.16 / 348.21 2 2
2 12 1126.04 4 10.61 1976 84 0.24 / 348.29 2 2
3 12 2000.96 41 11.09 3198 1454 1.70 / 349.74 2 2
4 7 1998.12 24 11.65 3242 906 2.60 / 350.65 2 2
5 13 1530.92 48 12.55 2581 1555 4.16 / 352.20 2 3
6 13 484.24 48 13.62 1063 695 4.85 / 352.90 2 8
7 8 -0.08 160 14.31 291 666 5.52 / 353.57 2 9
Average= 4.71 (KJ/cycle)

Cycle 73 GMT 18/ 9/2018 20:12: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 26 14.43 434 163 0.16 / 342.58 2 2
2 12 1142.80 4 10.94 2012 88 0.25 / 342.67 2 2
3 12 2001.68 41 11.07 3197 1451 1.70 / 344.12 2 2
4 7 1998.52 24 11.62 3242 904 2.61 / 345.02 2 2
5 13 1701.16 48 12.42 2802 1670 4.28 / 346.69 2 2
6 13 494.92 48 13.61 1068 698 4.97 / 347.39 2 8
7 8 0.04 160 14.33 286 656 5.63 / 348.05 2 9
Average= 4.70 (KJ/cycle)

Cycle 72 GMT 8/ 9/2018 20:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 26 14.45 419 157 0.16 / 336.96 2 2
2 12 1116.24 4 10.60 1970 84 0.24 / 337.05 2 2
3 12 2003.40 38 11.03 3198 1340 1.58 / 338.39 2 2
4 7 2000.64 24 11.63 3250 907 2.49 / 339.29 2 2
5 13 1560.48 48 12.54 2631 1584 4.07 / 340.88 2 2
6 13 421.08 48 13.70 972 639 4.71 / 341.52 2 8
7 13 40.16 48 14.32 354 243 4.95 / 341.76 2 6
8 8 -0.16 160 14.26 287 655 5.61 / 342.42 2 15
Average= 4.69 (KJ/cycle)

Cycle 71 GMT 29/ 8/2018 20:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 26 14.40 456 171 0.17 / 331.19 2 2
2 12 1121.84 4 10.77 1985 86 0.26 / 331.28 2 2
3 12 2001.48 38 11.01 3192 1335 1.59 / 332.61 2 2
4 7 1998.48 24 11.61 3255 907 2.50 / 333.52 2 2
5 13 1709.80 48 12.41 2816 1677 4.18 / 335.20 2 2
6 13 533.88 48 13.57 1121 730 4.91 / 335.93 2 7
7 13 28.68 48 14.35 333 229 5.14 / 336.16 2 6
8 8 -0.16 160 14.27 285 651 5.79 / 336.81 2 15
Average= 4.68 (KJ/cycle)

Cycle 70 GMT 19/ 8/2018 20: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 26 14.42 435 163 0.16 / 325.80 2 2
2 12 1141.72 4 10.87 2010 87 0.25 / 325.89 2 2
3 12 1998.96 38 11.05 3190 1339 1.59 / 327.23 2 2
4 7 1995.88 24 11.65 3264 913 2.50 / 328.14 2 2
5 13 1562.76 48 12.54 2653 1597 4.10 / 329.74 2 2
6 13 400.88 48 13.72 938 618 4.72 / 330.36 2 8
7 8 -0.08 160 14.30 289 661 5.38 / 331.02 2 9
Average= 4.66 (KJ/cycle)

Cycle 69 GMT 9/ 8/2018 19:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 26 14.42 426 160 0.16 / 320.43 2 2
2 12 1111.36 4 11.29 1965 89 0.25 / 320.52 2 2
3 12 1999.56 38 11.08 3208 1351 1.60 / 321.87 2 2
4 7 1996.48 24 11.70 3229 907 2.51 / 322.78 2 2
5 13 1559.48 48 12.55 2624 1581 4.09 / 324.36 2 2
6 13 411.44 48 13.72 949 625 4.71 / 324.98 2 8
7 8 -0.12 160 14.30 288 659 5.37 / 325.64 2 11
Average= 4.65 (KJ/cycle)

Cycle 68 GMT 30/ 7/2018 19:11: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 26 14.41 432 162 0.16 / 315.21 2 2
2 12 1121.80 4 11.49 1986 91 0.25 / 315.30 2 2
3 12 1978.76 38 11.06 3181 1337 1.59 / 316.64 2 2
4 7 1975.36 24 11.67 3207 898 2.49 / 317.54 2 2
5 13 1547.44 48 12.54 2619 1576 4.06 / 319.11 2 3
6 13 272.00 48 13.90 743 496 4.56 / 319.61 2 8
7 8 -0.08 160 14.28 289 660 5.22 / 320.27 2 13
Average= 4.64 (KJ/cycle)

Cycle 67 GMT 20/ 7/2018 18:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 26 14.44 437 164 0.16 / 310.12 2 2
2 12 1115.56 3 10.57 1970 62 0.23 / 310.18 2 2
3 12 2001.52 36 11.09 3213 1283 1.51 / 311.47 2 2
4 7 1998.52 24 11.72 3227 908 2.42 / 312.37 2 2
5 13 1422.84 48 12.67 2442 1485 3.90 / 313.86 2 3
6 13 306.52 48 13.86 791 526 4.43 / 314.39 2 8
7 8 -0.12 160 14.26 291 664 5.09 / 315.05 2 13
Average= 4.63 (KJ/cycle)

Cycle 66 GMT 10/ 7/2018 18:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 26 14.45 451 169 0.17 / 305.02 2 2
2 12 1108.52 3 10.88 1958 64 0.23 / 305.09 2 2
3 12 2003.24 36 11.13 3209 1286 1.52 / 306.37 2 2
4 7 2000.44 24 11.71 3252 914 2.43 / 307.29 2 2
5 13 1413.60 48 12.69 2421 1475 3.91 / 308.76 2 3
6 13 313.40 48 13.85 803 534 4.44 / 309.30 2 8
7 8 -0.16 160 14.29 289 661 5.10 / 309.96 2 8
Average= 4.63 (KJ/cycle)

Cycle 65 GMT 30/ 6/2018 18:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 26 14.44 434 163 0.16 / 299.82 2 2
2 12 1106.44 3 10.93 1975 65 0.23 / 299.89 2 2
3 12 2005.76 36 11.12 3232 1294 1.52 / 301.18 2 2
4 7 2003.12 24 11.76 3240 914 2.44 / 302.10 2 2
5 13 1464.88 48 12.67 2489 1514 3.95 / 303.61 2 3
6 13 338.24 48 13.82 851 565 4.51 / 304.18 2 8
7 8 -0.04 160 14.29 297 679 5.19 / 304.86 2 10
Average= 4.62 (KJ/cycle)

Cycle 64 GMT 20/ 6/2018 17:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 26 14.42 437 164 0.16 / 294.65 2 2
2 12 1126.12 3 11.55 2001 69 0.23 / 294.72 2 2
3 12 2001.52 36 11.20 3218 1297 1.53 / 296.02 2 2
4 7 1998.56 24 11.78 3244 917 2.45 / 296.94 2 2
5 13 1444.68 48 12.69 2465 1501 3.95 / 298.44 2 3
6 13 331.40 48 13.83 842 559 4.51 / 299.00 2 8
7 8 -0.20 160 14.29 290 663 5.17 / 299.66 2 11
Average= 4.61 (KJ/cycle)

Cycle 63 GMT 10/ 6/2018 17: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 26 14.45 431 162 0.16 / 289.29 2 2
2 7 2005.80 55 11.01 3236 1960 2.12 / 291.24 2 2
3 13 1607.08 48 12.54 2687 1617 3.74 / 292.86 2 2
4 13 515.96 48 13.62 1115 729 4.47 / 293.59 2 8
5 13 26.68 48 14.35 340 234 4.70 / 293.83 2 6
6 8 -0.20 160 14.24 292 665 5.37 / 294.49 2 12
Average= 4.60 (KJ/cycle)

Cycle 62 GMT 31/ 5/2018 17:23: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 26 14.47 438 165 0.16 / 283.82 2 2
2 7 2006.20 54 11.11 3230 1938 2.10 / 285.76 2 2
3 13 1872.08 47 12.29 3036 1754 3.86 / 287.51 2 2
4 13 566.08 47 13.59 1167 745 4.60 / 288.26 2 7
5 13 20.48 47 14.40 316 214 4.82 / 288.47 2 5
6 8 -0.20 160 14.24 285 649 5.46 / 289.12 2 13
Average= 4.59 (KJ/cycle)

Cycle 61 GMT 21/ 5/2018 17:33:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 26 14.49 428 161 0.16 / 278.23 2 2
2 7 2005.40 55 11.24 3236 2000 2.16 / 280.23 2 2
3 13 1877.96 47 12.30 3055 1766 3.93 / 282.00 2 2
4 13 589.44 47 13.56 1221 778 4.71 / 282.77 2 7
5 13 20.64 47 14.41 323 219 4.92 / 282.99 2 5
6 8 -0.12 160 14.24 292 665 5.59 / 283.66 2 11
Average= 4.58 (KJ/cycle)

Cycle 60 GMT 11/ 5/2018 18: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 26 14.49 425 160 0.16 / 272.90 2 2
2 7 2005.72 52 11.38 3235 1914 2.07 / 274.81 2 2
3 13 1876.52 44 12.36 3047 1657 3.73 / 276.47 2 2
4 13 601.12 44 13.59 1219 729 4.46 / 277.20 2 6
5 13 54.20 44 14.36 366 231 4.69 / 277.43 2 4
6 8 -0.04 160 14.31 278 637 5.33 / 278.07 2 12
Average= 4.56 (KJ/cycle)

Cycle 59 GMT 1/ 5/2018 18:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 26 14.50 424 160 0.16 / 267.57 2 2
2 7 2004.80 53 11.41 3243 1961 2.12 / 269.53 2 2
3 13 1728.72 44 12.56 2846 1573 3.69 / 271.11 2 2
4 13 638.36 44 13.56 1276 761 4.46 / 271.87 2 7
5 13 59.76 44 14.34 373 235 4.69 / 272.10 2 5
6 8 -0.04 160 14.30 278 636 5.33 / 272.74 2 11
Average= 4.55 (KJ/cycle)

Cycle 58 GMT 21/ 4/2018 17:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 26 14.50 439 166 0.17 / 262.10 2 2
2 7 2006.88 47 11.56 3253 1767 1.93 / 263.87 2 2
3 13 1873.36 44 12.40 3042 1660 3.59 / 265.53 2 2
4 13 872.96 44 13.34 1649 968 4.56 / 266.50 2 6
5 13 89.60 44 14.28 432 271 4.83 / 266.77 2 6
6 8 0.00 160 14.31 281 643 5.48 / 267.41 2 13
Average= 4.53 (KJ/cycle)

Cycle 57 GMT 11/ 4/2018 18:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 26 14.50 436 164 0.16 / 256.66 2 2
2 7 2005.24 47 11.66 3261 1787 1.95 / 258.44 2 2
3 13 1874.72 44 12.42 3040 1661 3.61 / 260.10 2 2
4 13 903.40 44 13.34 1670 980 4.59 / 261.08 2 7
5 13 21.48 44 14.39 320 203 4.80 / 261.29 2 5
6 8 0.12 160 14.27 285 651 5.45 / 261.94 2 10
Average= 4.52 (KJ/cycle)

Cycle 56 GMT 1/ 4/2018 19: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 26 14.48 431 162 0.16 / 251.47 2 2
2 7 2002.44 47 11.70 3247 1786 1.95 / 253.26 2 2
3 13 1735.56 44 12.60 2872 1592 3.54 / 254.85 2 2
4 13 660.60 44 13.57 1302 777 4.32 / 255.63 2 7
5 13 31.36 44 14.38 331 209 4.53 / 255.84 2 5
6 8 -0.04 160 14.26 287 655 5.18 / 256.49 2 11
Average= 4.50 (KJ/cycle)

Cycle 55 GMT 22/ 3/2018 19:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 26 14.44 454 170 0.17 / 246.40 2 2
2 7 2003.44 48 11.79 3243 1835 2.01 / 248.24 2 2
3 13 1870.96 44 12.45 3040 1665 3.67 / 249.91 2 2
4 13 632.16 44 13.60 1265 757 4.43 / 250.66 2 7
5 8 -0.12 160 14.31 283 648 5.08 / 251.31 2 8
Average= 4.49 (KJ/cycle)

Cycle 54 GMT 12/ 3/2018 19:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 26 14.53 433 164 0.16 / 241.21 2 2
2 7 2004.72 47 11.93 3239 1816 1.98 / 243.03 2 2
3 13 1740.44 44 12.65 2869 1597 3.58 / 244.63 2 2
4 13 648.84 44 13.59 1286 769 4.35 / 245.40 2 7
5 13 22.72 44 14.40 315 200 4.55 / 245.59 2 4
6 8 0.12 160 14.28 280 640 5.18 / 246.23 2 10
Average= 4.48 (KJ/cycle)

Cycle 53 GMT 2/ 3/2018 19:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 26 14.54 441 167 0.17 / 236.24 2 2
2 7 2000.48 47 11.95 3242 1821 1.99 / 238.06 2 2
3 13 1708.20 44 12.69 2839 1585 3.57 / 239.65 2 2
4 13 600.76 44 13.62 1246 747 4.32 / 240.39 2 7
5 8 0.00 160 14.33 286 656 4.98 / 241.05 2 10
Average= 4.46 (KJ/cycle)

Cycle 52 GMT 20/ 2/2018 19:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 26 14.49 426 160 0.16 / 231.07 2 2
2 7 2005.80 47 12.05 3240 1835 2.00 / 232.91 2 2
3 13 1872.96 44 12.51 3065 1687 3.68 / 234.60 2 2
4 13 729.96 44 13.53 1404 836 4.52 / 235.43 2 6
5 8 0.20 160 14.34 280 642 5.16 / 236.07 2 7
Average= 4.45 (KJ/cycle)

Cycle 51 GMT 10/ 2/2018 19:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 26 14.54 423 160 0.16 / 226.35 2 2
2 7 2003.44 47 12.15 3216 1836 2.00 / 228.19 2 2
3 13 1731.12 30 12.91 2853 1105 3.10 / 229.30 2 3
4 13 967.56 30 13.45 1772 715 3.82 / 230.01 2 5
5 13 209.08 30 14.15 626 266 4.08 / 230.28 2 6
6 8 0.16 160 14.32 278 637 4.72 / 230.91 2 10
Average= 4.44 (KJ/cycle)

Cycle 50 GMT 31/ 1/2018 19:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 26 14.52 424 160 0.16 / 221.62 2 2
2 7 2005.04 47 12.22 3246 1864 2.02 / 223.48 2 2
3 13 1600.24 30 13.02 2689 1050 3.07 / 224.53 2 3
4 13 1013.24 30 13.43 1844 743 3.82 / 225.28 2 5
5 13 223.56 30 14.14 653 277 4.09 / 225.55 2 7
6 8 -0.16 160 14.33 280 642 4.74 / 226.19 2 9
Average= 4.44 (KJ/cycle)

Cycle 49 GMT 21/ 1/2018 19:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 26 14.52 429 162 0.16 / 216.90 2 2
2 7 2004.88 47 12.23 3237 1861 2.02 / 218.76 2 2
3 13 1734.76 30 12.93 2876 1116 3.14 / 219.88 2 3
4 13 853.00 30 13.55 1598 650 3.79 / 220.53 2 5
5 13 256.84 30 14.10 705 298 4.09 / 220.83 2 7
6 8 0.08 160 14.35 275 631 4.72 / 221.46 2 9
Average= 4.43 (KJ/cycle)

Cycle 48 GMT 11/ 1/2018 19:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 26 14.55 424 160 0.16 / 212.17 2 2
2 7 2005.20 47 12.22 3239 1860 2.02 / 214.03 2 2
3 13 1735.56 30 12.92 2890 1120 3.14 / 215.15 2 3
4 13 850.24 30 13.54 1608 653 3.79 / 215.80 2 5
5 13 245.00 30 14.10 695 294 4.09 / 216.10 2 7
6 8 -0.12 160 14.32 280 642 4.73 / 216.74 2 7
Average= 4.42 (KJ/cycle)

Cycle 47 GMT 1/ 1/2018 19:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 26 14.54 435 164 0.16 / 207.54 2 2
2 7 2002.68 47 12.25 3254 1873 2.04 / 209.41 2 2
3 13 1577.12 32 13.03 2662 1110 3.15 / 210.52 2 3
4 13 727.20 32 13.65 1420 620 3.77 / 211.14 2 6
5 13 141.24 32 14.27 516 236 4.00 / 211.37 2 5
6 8 0.12 160 14.36 277 636 4.64 / 212.01 2 9
Average= 4.42 (KJ/cycle)

Cycle 46 GMT 22/12/2017 19:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 26 14.56 411 156 0.16 / 202.92 2 2
2 7 2002.60 47 12.25 3230 1860 2.02 / 204.78 2 2
3 13 1603.32 32 13.03 2684 1119 3.13 / 205.90 2 3
4 13 703.72 32 13.68 1375 602 3.74 / 206.50 2 5
5 13 132.72 32 14.29 500 229 3.96 / 206.73 2 5
6 8 0.04 160 14.34 280 642 4.61 / 207.37 2 7
Average= 4.41 (KJ/cycle)

Cycle 45 GMT 12/12/2017 19:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 26 14.57 424 161 0.16 / 198.08 2 2
2 7 2001.96 47 12.26 3223 1857 2.02 / 199.94 2 2
3 13 1872.68 32 12.78 3042 1244 3.26 / 201.18 2 2
4 13 808.72 32 13.59 1532 666 3.93 / 201.85 2 5
5 13 201.88 32 14.18 616 280 4.21 / 202.12 2 7
6 8 0.00 160 14.35 278 638 4.85 / 202.76 2 12
Average= 4.41 (KJ/cycle)

Cycle 44 GMT 2/12/2017 19:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 25 14.58 434 158 0.16 / 193.29 2 2
2 7 2003.96 47 12.29 3238 1870 2.03 / 195.16 2 2
3 13 1746.64 32 12.94 2900 1201 3.23 / 196.36 2 3
4 13 840.76 32 13.57 1598 694 3.92 / 197.05 2 5
5 13 119.72 32 14.32 484 222 4.15 / 197.27 2 5
6 8 -0.04 160 14.35 280 643 4.79 / 197.92 2 7
Average= 4.40 (KJ/cycle)

Cycle 43 GMT 22/11/2017 19:29: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 25 14.59 413 151 0.15 / 187.93 2 2
2 7 2005.48 47 12.34 3237 1877 2.03 / 189.80 2 2
3 13 1879.64 45 12.59 3039 1722 3.75 / 191.53 2 2
4 13 629.40 45 13.66 1254 771 4.52 / 192.30 2 7
5 13 51.56 45 14.40 359 233 4.75 / 192.53 2 5
6 8 -0.08 150 14.34 279 600 5.35 / 193.13 2 10
Average= 4.39 (KJ/cycle)

Cycle 42 GMT 12/11/2017 19:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 25 14.58 421 153 0.15 / 182.67 2 2
2 7 2006.76 47 12.38 3237 1883 2.04 / 184.55 2 2
3 13 1737.80 45 12.77 2875 1652 3.69 / 186.21 2 2
4 13 604.52 45 13.68 1217 749 4.44 / 186.95 2 7
5 13 47.52 45 14.39 352 228 4.67 / 187.18 2 5
6 8 -0.08 150 14.34 276 594 5.26 / 187.78 2 11
Average= 4.37 (KJ/cycle)

Cycle 41 GMT 2/11/2017 19:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 25 14.56 420 153 0.15 / 177.54 2 2
2 7 2002.20 48 12.39 3232 1922 2.08 / 179.46 2 2
3 13 1726.48 45 12.81 2838 1636 3.71 / 181.10 2 2
4 13 446.92 45 13.84 988 615 4.33 / 181.71 2 7
5 13 22.24 45 14.44 314 204 4.53 / 181.92 2 5
6 8 -0.16 150 14.34 278 598 5.13 / 182.52 2 12
Average= 4.35 (KJ/cycle)

Cycle 40 GMT 23/10/2017 19:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 25 14.60 424 155 0.15 / 172.79 2 2
2 7 2001.92 47 12.47 3213 1883 2.04 / 174.68 2 2
3 13 1455.00 45 13.02 2473 1449 3.49 / 176.13 2 3
4 13 499.40 45 13.79 1066 662 4.15 / 176.79 2 6
5 8 0.04 150 14.36 279 601 4.75 / 177.39 2 7
Average= 4.33 (KJ/cycle)

Cycle 39 GMT 13/10/2017 20:14: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 25 14.61 421 154 0.15 / 167.72 2 2
2 7 2003.72 47 12.50 3229 1897 2.05 / 169.62 2 2
3 13 1605.44 45 12.93 2683 1561 3.61 / 171.18 2 3
4 13 485.44 45 13.82 1042 648 4.26 / 171.83 2 7
5 13 29.12 45 14.43 329 214 4.47 / 172.04 2 6
6 8 -0.08 150 14.33 278 598 5.07 / 172.64 2 12
Average= 4.32 (KJ/cycle)

Cycle 38 GMT 3/10/2017 20:34: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 25 14.62 413 151 0.15 / 162.64 2 2
2 7 2000.88 47 12.55 3231 1906 2.06 / 164.55 2 2
3 13 1597.80 45 12.97 2652 1548 3.60 / 166.09 2 4
4 13 499.20 45 13.82 1062 660 4.27 / 166.75 2 8
5 13 29.96 45 14.44 326 212 4.48 / 166.97 2 6
6 8 -0.24 150 14.33 280 602 5.08 / 167.57 2 9
Average= 4.30 (KJ/cycle)

Cycle 37 GMT 23/ 9/2017 20:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 25 14.62 415 152 0.15 / 157.66 2 2
2 7 2004.24 47 12.59 3207 1898 2.05 / 159.56 2 2
3 13 1463.92 45 13.05 2483 1458 3.51 / 161.01 2 4
4 13 501.36 45 13.82 1069 665 4.17 / 161.68 2 7
5 13 27.20 45 14.44 321 209 4.38 / 161.89 2 5
6 8 -0.04 150 14.33 280 602 4.98 / 162.49 2 12
Average= 4.28 (KJ/cycle)

Cycle 36 GMT 13/ 9/2017 20:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 25 14.60 421 154 0.15 / 152.49 2 2
2 7 2004.64 47 12.60 3249 1924 2.08 / 154.41 2 2
3 13 1732.08 45 12.88 2867 1662 3.74 / 156.07 2 3
4 13 436.52 45 13.89 970 606 4.35 / 156.68 2 7
5 13 44.60 45 14.42 353 229 4.57 / 156.91 2 6
6 8 -0.20 150 14.35 277 596 5.17 / 157.51 2 11
Average= 4.26 (KJ/cycle)

Cycle 35 GMT 3/ 9/2017 20:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 25 14.59 421 154 0.15 / 147.01 2 2
2 7 2007.60 47 12.64 3202 1902 2.06 / 148.92 2 2
3 13 1877.56 45 12.71 3050 1744 3.80 / 150.66 2 2
4 13 709.92 45 13.65 1385 851 4.65 / 151.51 2 7
5 13 30.80 45 14.45 331 215 4.87 / 151.73 2 5
6 8 -0.16 150 14.34 283 609 5.47 / 152.33 2 12
Average= 4.23 (KJ/cycle)

Cycle 34 GMT 24/ 8/2017 21: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 25 14.60 418 153 0.15 / 141.90 2 2
2 7 2004.48 47 12.66 3215 1913 2.07 / 143.81 2 2
3 13 1597.64 45 12.99 2657 1553 3.62 / 145.36 2 3
4 13 512.88 45 13.82 1087 676 4.29 / 146.04 2 8
5 13 26.56 45 14.46 327 213 4.51 / 146.25 2 6
6 8 -0.12 150 14.34 282 607 5.11 / 146.86 2 12
Average= 4.20 (KJ/cycle)

Cycle 33 GMT 14/ 8/2017 20:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 25 14.62 426 156 0.16 / 136.60 2 2
2 7 2002.96 48 12.60 3233 1955 2.11 / 138.55 2 2
3 13 1718.36 45 12.90 2827 1641 3.75 / 140.19 2 3
4 13 591.28 45 13.75 1198 741 4.49 / 140.93 2 7
5 13 20.48 45 14.48 313 204 4.70 / 141.14 2 5
6 8 -0.16 150 14.31 283 607 5.30 / 141.75 2 13
Average= 4.17 (KJ/cycle)

Cycle 32 GMT 4/ 8/2017 20:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 25 14.64 421 154 0.15 / 132.13 2 2
2 7 2001.72 47 12.66 3214 1912 2.07 / 134.05 2 2
3 13 1589.04 30 13.17 2647 1046 3.11 / 135.09 2 3
4 13 599.52 30 13.84 1217 505 3.62 / 135.60 2 6
5 13 170.24 30 14.30 568 244 3.86 / 135.84 2 7
6 8 -0.20 150 14.40 278 600 4.46 / 136.44 2 10
Average= 4.13 (KJ/cycle)

Cycle 31 GMT 25/ 7/2017 20: 6: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 25 14.63 418 153 0.15 / 127.64 2 2
2 7 2002.92 48 12.67 3208 1951 2.10 / 129.59 2 2
3 13 1437.08 30 13.24 2467 980 3.08 / 130.57 2 4
4 13 728.52 30 13.75 1419 585 3.67 / 131.15 2 6
5 13 133.24 30 14.35 509 219 3.89 / 131.37 2 6
6 8 -0.20 150 14.41 280 605 4.49 / 131.98 2 7
Average= 4.12 (KJ/cycle)

Cycle 30 GMT 15/ 7/2017 19:14: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 25 14.63 424 155 0.16 / 123.14 2 2
2 7 2003.44 47 12.70 3226 1926 2.08 / 125.06 2 2
3 13 1595.08 30 13.17 2645 1045 3.13 / 126.11 2 4
4 13 705.44 30 13.77 1378 569 3.69 / 126.68 2 6
5 13 141.20 30 14.37 510 220 3.91 / 126.89 2 6
6 8 0.04 150 14.43 273 591 4.51 / 127.49 2 6
Average= 4.11 (KJ/cycle)

Cycle 29 GMT 5/ 7/2017 18:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 25 14.63 420 154 0.15 / 118.55 2 2
2 7 2002.88 47 12.73 3216 1924 2.08 / 120.47 2 2
3 13 1586.96 30 13.18 2673 1057 3.13 / 121.53 2 3
4 13 843.76 30 13.68 1581 649 3.78 / 122.18 2 6
5 13 123.12 30 14.38 487 210 3.99 / 122.39 2 6
6 8 0.08 150 14.42 275 595 4.59 / 122.98 2 11
Average= 4.10 (KJ/cycle)

Cycle 28 GMT 25/ 6/2017 18:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 25 14.65 409 150 0.15 / 113.82 2 2
2 7 2001.64 47 12.72 3238 1936 2.09 / 115.76 2 2
3 13 1730.04 30 13.09 2866 1125 3.21 / 116.88 2 3
4 13 821.04 30 13.70 1550 637 3.85 / 117.52 2 6
5 13 206.76 30 14.27 631 270 4.12 / 117.79 2 8
6 8 -0.20 150 14.41 278 601 4.72 / 118.39 2 5
Average= 4.08 (KJ/cycle)

Cycle 27 GMT 15/ 6/2017 18:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 25 14.63 435 159 0.16 / 109.54 2 2
2 7 2002.56 39 12.85 3250 1629 1.79 / 111.17 2 2
3 13 1639.08 29 13.18 2762 1056 2.84 / 112.23 2 3
4 13 850.88 29 13.71 1593 633 3.48 / 112.86 2 6
5 13 157.04 29 14.37 540 225 3.70 / 113.08 2 5
6 8 -0.04 150 14.46 271 588 4.29 / 113.67 2 8
Average= 4.06 (KJ/cycle)

Cycle 26 GMT 5/ 6/2017 17:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 25 14.67 424 156 0.16 / 105.07 2 2
2 7 2001.60 39 12.87 3245 1629 1.78 / 106.70 2 2
3 13 1609.64 29 13.20 2702 1034 2.82 / 107.73 2 3
4 13 819.52 29 13.73 1549 617 3.44 / 108.35 2 5
5 13 252.32 29 14.25 703 291 3.73 / 108.64 2 7
6 13 43.04 29 14.53 347 146 3.87 / 108.79 2 4
7 8 -0.16 150 14.43 276 597 4.47 / 109.38 2 9
Average= 4.05 (KJ/cycle)

Cycle 25 GMT 26/ 5/2017 17: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 25 14.66 434 159 0.16 / 100.73 2 2
2 7 2001.64 40 12.88 3229 1664 1.82 / 102.39 2 2
3 13 1765.44 29 13.12 2916 1109 2.93 / 103.50 2 3
4 13 805.00 29 13.76 1529 610 3.54 / 104.11 2 5
5 13 146.40 29 14.43 516 216 3.76 / 104.33 2 4
6 8 0.00 150 14.47 271 588 4.35 / 104.91 2 5
Average= 4.04 (KJ/cycle)

Cycle 24 GMT 16/ 5/2017 16:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 25 14.66 430 158 0.16 / 96.48 2 2
2 7 2009.40 39 12.85 3253 1630 1.79 / 98.11 2 2
3 13 1527.24 29 13.25 2591 996 2.78 / 99.10 2 3
4 13 852.16 29 13.72 1595 635 3.42 / 99.74 2 5
5 13 166.80 29 14.38 555 231 3.65 / 99.97 2 5
6 8 -0.20 150 14.46 275 596 4.25 / 100.57 2 12
Average= 4.02 (KJ/cycle)

Cycle 23 GMT 6/ 5/2017 15:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 25 14.72 405 149 0.15 / 92.09 2 2
2 7 2001.92 39 12.88 3244 1630 1.78 / 93.72 2 2
3 13 1746.68 29 13.13 2887 1099 2.88 / 94.82 2 3
4 13 893.08 29 13.70 1659 659 3.54 / 95.48 2 6
5 13 206.36 29 14.35 616 256 3.79 / 95.74 2 5
6 8 0.00 150 14.50 269 585 4.38 / 96.32 2 6
Average= 4.01 (KJ/cycle)

Cycle 22 GMT 26/ 4/2017 14:28: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 25 14.69 403 148 0.15 / 87.65 2 2
2 7 2018.28 39 12.86 3237 1623 1.77 / 89.27 2 2
3 13 1775.80 29 13.13 2908 1107 2.88 / 90.38 2 3
4 13 1066.36 29 13.59 1899 748 3.63 / 91.13 2 6
5 13 207.48 29 14.36 603 251 3.88 / 91.38 2 5
6 8 0.12 150 14.52 258 562 4.44 / 91.94 2 7
Average= 4.00 (KJ/cycle)

Cycle 21 GMT 16/ 4/2017 13:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 25 14.68 404 148 0.15 / 83.40 2 2
2 7 2004.80 40 12.88 3194 1646 1.79 / 85.04 2 2
3 13 1634.68 29 13.22 2713 1040 2.83 / 86.08 2 3
4 13 785.32 29 13.79 1485 594 3.43 / 86.68 2 6
5 13 224.76 29 14.33 635 264 3.69 / 86.94 2 7
6 8 0.04 150 14.48 258 560 4.25 / 87.50 2 6
Average= 3.98 (KJ/cycle)

Cycle 20 GMT 6/ 4/2017 12:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 25 14.68 413 152 0.15 / 78.95 2 2
2 7 2003.16 39 12.88 3227 1621 1.77 / 80.57 2 2
3 13 1758.60 29 13.14 2892 1102 2.87 / 81.67 2 3
4 13 801.16 29 13.79 1510 604 3.48 / 82.28 2 6
5 13 247.88 29 14.30 678 281 3.76 / 82.56 2 7
6 13 17.44 29 14.63 288 122 3.88 / 82.68 2 4
7 8 -0.24 150 14.42 264 571 4.45 / 83.25 2 9
Average= 3.96 (KJ/cycle)

Cycle 19 GMT 27/ 3/2017 11:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 25 14.70 413 152 0.15 / 74.75 2 2
2 7 1966.00 39 12.93 3170 1599 1.75 / 76.35 2 2
3 13 1694.72 29 13.18 2817 1077 2.83 / 77.42 2 3
4 13 741.36 29 13.85 1420 570 3.40 / 77.99 2 6
5 13 196.56 29 14.37 593 247 3.64 / 78.24 2 6
6 8 0.04 150 14.52 256 558 4.20 / 78.80 2 7
Average= 3.94 (KJ/cycle)

Cycle 18 GMT 17/ 3/2017 9:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 24 14.74 408 144 0.14 / 70.49 2 2
2 7 2002.00 39 12.93 3227 1627 1.77 / 72.11 2 2
3 13 1759.80 29 13.17 2886 1102 2.87 / 73.22 2 3
4 13 752.68 29 13.85 1430 574 3.45 / 73.79 2 6
5 13 195.36 29 14.38 588 245 3.69 / 74.04 2 6
6 8 0.04 150 14.52 257 560 4.25 / 74.60 2 6
Average= 3.93 (KJ/cycle)

Cycle 17 GMT 7/ 3/2017 9:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 24 14.69 404 142 0.14 / 66.36 2 2
2 7 2002.88 39 12.93 3205 1616 1.76 / 67.97 2 2
3 13 1637.36 28 13.24 2735 1014 2.77 / 68.99 2 3
4 13 826.16 28 13.80 1543 596 3.37 / 69.58 2 7
5 13 154.08 28 14.46 509 206 3.57 / 69.79 2 5
6 8 0.12 150 14.53 254 554 4.13 / 70.34 2 15
Average= 3.91 (KJ/cycle)

Cycle 16 GMT 25/ 2/2017 8:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 24 14.68 416 147 0.15 / 62.01 2 2
2 7 2004.28 39 12.95 3212 1622 1.77 / 63.63 2 2
3 13 1631.80 28 13.27 2694 1001 2.77 / 64.63 2 3
4 13 927.16 28 13.73 1688 649 3.42 / 65.28 2 6
5 13 216.80 28 14.35 631 254 3.67 / 65.53 2 7
6 13 19.40 28 14.65 289 119 3.79 / 65.65 2 4
7 8 0.12 150 14.47 260 564 4.36 / 66.21 2 12
Average= 3.89 (KJ/cycle)

Cycle 15 GMT 15/ 2/2017 8: 7: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 24 14.68 414 146 0.15 / 57.77 2 2
2 7 2003.44 39 12.97 3202 1620 1.77 / 59.39 2 2
3 13 1635.36 28 13.27 2699 1003 2.77 / 60.39 2 3
4 13 917.44 28 13.75 1674 644 3.41 / 61.03 2 6
5 13 203.72 28 14.35 618 248 3.66 / 61.28 2 7
6 8 0.08 150 14.49 265 576 4.24 / 61.86 2 8
Average= 3.87 (KJ/cycle)

Cycle 14 GMT 5/ 2/2017 7:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 24 14.67 413 145 0.15 / 53.61 2 2
2 7 2004.48 40 12.96 3218 1668 1.81 / 55.28 2 2
3 13 1526.36 28 13.33 2549 951 2.77 / 56.23 2 3
4 13 833.84 28 13.81 1555 601 3.37 / 56.83 2 6
5 13 149.48 28 14.46 519 210 3.58 / 57.04 2 6
6 8 -0.04 150 14.49 266 578 4.15 / 57.62 2 9
Average= 3.84 (KJ/cycle)

Cycle 13 GMT 26/ 1/2017 5:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 24 14.70 405 143 0.14 / 49.54 2 2
2 7 2005.40 39 13.00 3209 1627 1.77 / 51.16 2 2
3 13 1497.88 28 13.34 2525 943 2.71 / 52.11 2 4
4 13 825.04 28 13.81 1531 592 3.30 / 52.70 2 6
5 13 135.20 28 14.47 493 200 3.50 / 52.90 2 6
6 8 0.12 150 14.49 261 567 4.07 / 53.47 2 9
Average= 3.82 (KJ/cycle)

Cycle 12 GMT 16/ 1/2017 4:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 24 14.69 409 144 0.14 / 45.15 2 2
2 7 2007.00 39 13.01 3214 1631 1.77 / 46.78 2 2
3 13 1892.16 28 13.09 3066 1124 2.90 / 47.91 2 3
4 13 1001.80 28 13.69 1799 690 3.59 / 48.60 2 6
5 13 168.64 28 14.42 553 223 3.81 / 48.82 2 6
6 8 0.08 150 14.48 265 576 4.39 / 49.39 2 9
Average= 3.80 (KJ/cycle)

Cycle 11 GMT 6/ 1/2017 3:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 24 14.72 403 142 0.14 / 40.87 2 2
2 7 2004.72 39 13.03 3207 1630 1.77 / 42.50 2 2
3 13 1633.60 28 13.29 2699 1004 2.78 / 43.51 2 3
4 13 943.72 28 13.73 1718 660 3.44 / 44.17 2 6
5 13 220.80 28 14.34 642 258 3.69 / 44.42 2 7
6 8 -0.16 150 14.46 269 583 4.28 / 45.01 2 7
Average= 3.75 (KJ/cycle)

Cycle 10 GMT 27/12/2016 2:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 24 14.72 414 146 0.15 / 36.64 2 2
2 7 2003.08 40 12.99 3216 1671 1.82 / 38.31 2 2
3 13 1616.68 28 13.29 2699 1004 2.82 / 39.32 2 3
4 13 779.24 28 13.85 1475 572 3.39 / 39.89 2 6
5 13 224.36 28 14.34 649 261 3.65 / 40.15 2 8
6 8 -0.04 150 14.48 267 580 4.23 / 40.73 2 8
Average= 3.70 (KJ/cycle)

Cycle 9 GMT 17/12/2016 1:29: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 24 14.73 405 143 0.14 / 32.34 2 2
2 7 2001.68 39 13.02 3223 1637 1.78 / 33.98 2 2
3 13 1637.20 31 13.25 2699 1109 2.89 / 35.08 2 3
4 13 805.52 31 13.80 1508 645 3.53 / 35.73 2 6
5 13 113.44 31 14.52 453 204 3.74 / 35.93 2 6
6 8 0.08 150 14.52 258 562 4.30 / 36.50 2 12
Average= 3.65 (KJ/cycle)

Cycle 8 GMT 6/12/2016 23:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 24 14.77 390 138 0.14 / 28.05 2 2
2 7 2002.32 39 13.03 3202 1627 1.77 / 29.68 2 2
3 13 1633.20 31 13.24 2715 1114 2.88 / 30.79 2 4
4 13 794.80 31 13.81 1491 638 3.52 / 31.43 2 6
5 13 112.92 31 14.53 448 202 3.72 / 31.63 2 5
6 8 -0.04 150 14.50 259 563 4.28 / 32.20 2 9
Average= 3.58 (KJ/cycle)

Cycle 7 GMT 26/11/2016 22:17: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 24 14.74 398 141 0.14 / 23.75 2 2
2 7 1996.12 41 12.98 3199 1702 1.84 / 25.46 2 2
3 13 1508.24 29 13.33 2552 987 2.83 / 26.44 2 4
4 13 929.36 29 13.73 1686 671 3.50 / 27.11 2 5
5 13 182.76 29 14.42 571 239 3.74 / 27.35 2 6
6 8 -0.04 150 14.51 257 559 4.30 / 27.91 2 11
Average= 3.49 (KJ/cycle)

Cycle 6 GMT 16/11/2016 20:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 23 14.72 392 133 0.13 / 19.48 2 2
2 3 1020.56 1 14.39 1904 27 0.16 / 19.50 2 2
3 7 2001.72 45 12.90 3215 1866 2.03 / 21.37 2 2
4 13 1473.20 26 13.39 2470 860 2.89 / 22.23 2 4
5 13 800.00 26 13.83 1502 540 3.43 / 22.77 2 7
6 13 127.56 26 14.51 477 180 3.61 / 22.95 2 6
7 13 14.08 26 14.69 282 108 3.71 / 23.06 2 4
8 8 -0.12 150 14.44 257 557 4.27 / 23.61 2 11
Average= 3.37 (KJ/cycle)

Cycle 5 GMT 6/11/2016 19:15:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 24 14.70 403 142 0.14 / 15.34 2 2
2 3 942.12 -1 15.45 0 0 0.00 / 15.34 2 2
3 7 1985.44 46 12.92 3170 1884 2.03 / 17.22 2 2
4 13 1359.96 26 13.42 2317 808 2.83 / 18.03 2 4
5 13 580.00 26 13.98 1177 428 3.26 / 18.46 2 6
6 13 187.08 26 14.40 579 217 3.48 / 18.67 2 7
7 13 14.08 26 14.68 282 108 3.59 / 18.78 2 6
8 8 -0.08 150 14.42 260 562 4.15 / 19.34 2 10
Average= 3.22 (KJ/cycle)

Cycle 4 GMT 27/10/2016 18:14: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 23 14.69 395 133 0.13 / 11.75 2 2
2 7 1506.04 45 13.27 2514 1501 1.63 / 13.25 2 3
3 13 1386.40 26 13.44 2362 825 2.46 / 14.07 2 4
4 13 552.32 26 14.01 1136 414 2.87 / 14.49 2 6
5 13 63.08 26 14.61 368 140 3.01 / 14.63 2 6
6 8 -0.04 150 14.46 261 566 3.58 / 15.19 2 11
Average= 3.04 (KJ/cycle)

Cycle 3 GMT 26/10/2016 18:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 23 14.69 404 136 0.14 / 8.25 2 2
2 7 1505.04 46 13.20 2523 1532 1.67 / 9.78 2 2
3 13 1141.80 26 13.52 2008 706 2.37 / 10.49 2 5
4 13 582.40 26 13.92 1171 424 2.80 / 10.91 2 6
5 13 63.20 26 14.56 375 142 2.94 / 11.05 2 6
6 8 -0.28 150 14.43 260 563 3.50 / 11.61 2 6
Average= 2.90 (KJ/cycle)

Cycle 2 GMT 25/10/2016 19:15:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 24 14.66 387 136 0.14 / 4.22 2 2
2 3 938.68 -1 15.42 0 0 0.00 / 4.22 2 2
3 7 1512.00 74 12.87 2523 2403 2.54 / 6.63 2 3
4 13 635.20 25 13.87 1248 433 2.97 / 7.06 2 5
5 13 103.20 25 14.45 442 160 3.13 / 7.22 2 6
6 8 -0.20 240 14.31 260 893 4.02 / 8.11 2 34
Average= 2.70 (KJ/cycle)

Cycle 1 GMT 24/10/2016 19:51:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 24 14.69 371 131 0.13 / 1.39 2 2
2 3 933.00 -1 15.37 0 0 0.00 / 1.39 2 2
3 7 985.08 74 13.06 1753 1694 1.82 / 3.09 2 5
4 13 37.36 25 14.50 323 117 1.94 / 3.20 2 5
5 8 -0.48 240 14.27 258 884 2.83 / 4.09 2 66
Average= 2.04 (KJ/cycle)

Cycle 0 GMT 24/10/2016 8:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 81.08 24 14.31 353 121 0.12 / 0.12 2 2
2 7 91.28 74 14.22 361 380 0.50 / 0.50 2 2
3 8 -0.00 240 14.46 219 760 1.26 / 1.26 2 27
Average= 1.26 (KJ/cycle)