SIO Argo Site:
Pump Diagnostics Page   



Serial= 8472 WMO= 5902480

Return

←PreviousNext→

Cycle 273 GMT 14/ 8/2023 14:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 46 9.15 1584 667 0.67 / 1643.05 3 3
2 10 1037.96 3 6.85 2926 60 0.73 / 1643.11 3 3
3 3 1092.88 2 6.99 2911 41 0.77 / 1643.15 3 3
4 3 1077.08 2 6.97 2909 41 0.81 / 1643.19 3 3
5 12 1188.40 85 6.74 2814 1612 2.42 / 1644.80 3 3
6 7 1189.48 24 6.81 2820 461 2.88 / 1645.26 3 3
7 13 1117.80 40 6.76 2865 775 3.66 / 1646.04 3 3
8 13 1012.28 40 7.00 2727 764 4.42 / 1646.80 3 3
9 13 881.56 40 7.20 2610 752 5.17 / 1647.55 3 3
10 13 64.68 40 8.76 1696 594 5.77 / 1648.15 3 3
11 8 0.04 160 9.15 1441 2110 7.87 / 1650.26 3 10
Average= 6.02 (KJ/cycle)

Cycle 272 GMT 4/ 8/2023 20:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 48 9.40 1567 707 0.71 / 1635.65 3 3
2 3 1055.88 1 7.00 3070 21 0.73 / 1635.67 3 3
3 3 1040.64 1 7.24 3051 22 0.75 / 1635.70 3 3
4 12 1173.04 85 6.80 2905 1679 2.43 / 1637.38 3 3
5 7 1174.40 24 6.87 2878 475 2.90 / 1637.85 3 3
6 13 1103.48 40 6.90 2933 810 3.71 / 1638.66 3 3
7 13 991.56 40 7.22 2748 794 4.51 / 1639.45 3 3
8 13 720.40 40 7.48 2557 765 5.27 / 1640.22 3 3
9 8 -0.20 160 9.20 1471 2165 7.44 / 1642.38 3 6
Average= 6.02 (KJ/cycle)

Cycle 271 GMT 26/ 7/2023 2: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 45 9.96 1060 475 0.48 / 1628.62 3 3
2 3 1060.64 2 7.91 2580 41 0.52 / 1628.66 3 3
3 3 1044.04 1 7.83 2566 20 0.54 / 1628.68 3 3
4 12 1165.04 85 7.54 2465 1580 2.12 / 1630.26 3 3
5 7 1163.40 24 7.53 2513 454 2.57 / 1630.71 3 3
6 13 1066.68 40 7.72 2434 752 3.32 / 1631.46 3 3
7 13 805.68 40 8.17 2133 697 4.02 / 1632.16 3 3
8 13 41.60 40 9.33 1426 532 4.55 / 1632.69 3 3
9 8 0.08 160 9.21 1528 2252 6.80 / 1634.95 3 4
Average= 6.01 (KJ/cycle)

Cycle 270 GMT 16/ 7/2023 7:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 45 9.93 1064 475 0.48 / 1614.91 3 3
2 12 1108.52 6 7.76 2495 116 0.59 / 1615.02 3 3
3 12 2008.52 85 6.11 3617 1878 2.47 / 1616.90 3 3
4 7 2008.40 24 6.13 3621 533 3.00 / 1617.43 3 3
5 13 1989.72 40 6.11 3639 889 3.89 / 1618.32 3 3
6 13 1981.52 40 6.12 3648 893 4.79 / 1619.22 3 3
7 13 1972.20 40 6.11 3652 893 5.68 / 1620.11 3 3
8 13 1972.80 40 6.24 3575 892 6.57 / 1621.00 3 3
9 13 1924.84 40 6.22 3561 886 7.46 / 1621.89 3 3
10 13 1856.28 40 6.32 3503 886 8.34 / 1622.77 3 3
11 13 1758.52 40 6.67 3279 875 9.22 / 1623.65 3 3
12 13 1632.40 40 6.63 3293 873 10.09 / 1624.52 3 3
13 13 1363.96 40 7.15 2906 831 10.92 / 1625.35 3 3
14 13 944.44 40 7.88 2412 760 11.68 / 1626.11 3 3
15 13 119.96 40 9.60 1287 494 12.18 / 1626.61 3 3
16 8 0.04 160 10.02 959 1537 13.71 / 1628.14 3 4
Average= 6.01 (KJ/cycle)

Cycle 269 GMT 15/ 7/2023 3: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 48 10.07 1022 494 0.49 / 1608.84 3 3
2 3 890.60 -2 11.64 1 0 0.00 / 1608.84 3 3
3 12 1152.52 85 7.65 2469 1605 2.10 / 1610.44 3 3
4 7 1151.20 24 7.72 2533 469 2.57 / 1610.91 3 3
5 13 1054.20 40 7.79 2469 769 3.34 / 1611.68 3 3
6 13 660.40 40 8.56 1959 671 4.01 / 1612.35 3 3
7 13 20.20 40 9.82 1089 428 4.44 / 1612.78 3 3
8 8 -0.20 160 9.95 1038 1652 6.09 / 1614.43 3 3
Average= 5.98 (KJ/cycle)

Cycle 268 GMT 5/ 7/2023 8:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 45 10.06 1097 497 0.50 / 1602.77 3 3
2 12 1147.24 85 7.76 2501 1650 2.15 / 1604.42 3 3
3 7 1145.48 24 7.19 2998 517 2.66 / 1604.94 3 3
4 13 1037.92 40 8.01 2420 775 3.44 / 1605.71 3 3
5 13 763.88 40 8.04 2412 776 4.21 / 1606.49 3 3
6 13 17.88 40 9.96 1059 422 4.64 / 1606.91 3 3
7 8 -0.12 160 10.16 881 1432 6.07 / 1608.34 3 8
Average= 5.98 (KJ/cycle)

Cycle 267 GMT 25/ 6/2023 14:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 44 10.08 1057 469 0.47 / 1597.19 3 3
2 12 1146.40 85 7.87 2499 1672 2.14 / 1598.86 3 3
3 7 1144.56 24 7.95 2555 487 2.63 / 1599.35 3 3
4 13 1037.04 40 8.08 2445 790 3.42 / 1600.14 3 3
5 13 501.36 40 9.09 1728 628 4.05 / 1600.77 3 3
6 8 0.36 160 10.16 927 1507 5.55 / 1602.27 3 6
Average= 5.98 (KJ/cycle)

Cycle 266 GMT 15/ 6/2023 20:19:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 45 10.13 1065 485 0.49 / 1589.00 3 3
2 3 966.12 -1 11.64 1 0 0.00 / 1589.00 3 3
3 3 1035.68 1 8.14 2706 22 0.51 / 1589.02 3 3
4 12 1150.76 6 7.91 2624 125 0.63 / 1589.14 3 3
5 12 2001.64 85 6.69 3561 2025 2.66 / 1591.17 3 3
6 7 1996.80 24 6.66 3557 569 3.23 / 1591.74 3 3
7 13 1872.88 40 6.72 3627 975 4.20 / 1592.71 3 3
8 13 1494.12 40 7.38 3080 909 5.11 / 1593.62 3 3
9 13 1091.16 40 8.03 2579 828 5.94 / 1594.45 3 3
10 13 400.64 40 9.34 1643 614 6.55 / 1595.06 3 3
11 8 0.08 160 10.10 1024 1655 8.21 / 1596.72 3 6
Average= 5.98 (KJ/cycle)

Cycle 265 GMT 14/ 6/2023 17:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 46 10.14 1063 496 0.50 / 1581.48 3 3
2 3 1037.40 1 7.70 3286 25 0.52 / 1581.51 3 3
3 3 1028.68 1 7.48 3279 25 0.55 / 1581.53 3 3
4 12 1151.40 85 7.60 2891 1868 2.41 / 1583.40 3 3
5 7 1150.72 25 7.47 3049 569 2.98 / 1583.97 3 3
6 13 1051.84 40 7.54 3051 920 3.90 / 1584.89 3 3
7 13 794.88 40 8.03 2684 862 4.76 / 1585.75 3 3
8 13 106.76 40 9.03 1984 717 5.48 / 1586.47 3 3
9 8 -0.24 160 9.76 1310 2046 7.53 / 1588.51 3 7
Average= 5.97 (KJ/cycle)

Cycle 264 GMT 4/ 6/2023 23: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 44 10.15 1104 493 0.49 / 1574.25 3 3
2 12 1130.88 85 8.05 2589 1772 2.26 / 1576.02 3 3
3 7 1128.72 24 8.12 2637 514 2.78 / 1576.53 3 3
4 13 1012.00 40 8.03 2781 893 3.67 / 1577.43 3 3
5 13 607.64 40 8.78 2144 753 4.42 / 1578.18 3 3
6 13 27.52 40 9.98 1182 472 4.90 / 1578.65 3 3
7 8 0.00 160 9.61 1518 2334 7.23 / 1580.98 3 5
Average= 5.97 (KJ/cycle)

Cycle 263 GMT 26/ 5/2023 4:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 43 10.14 1088 474 0.47 / 1568.30 3 3
2 3 1033.56 1 8.14 2999 24 0.50 / 1568.33 3 3
3 3 1026.68 1 8.33 2855 24 0.52 / 1568.35 3 3
4 12 1149.08 85 8.14 2610 1806 2.33 / 1570.16 3 3
5 7 1146.68 24 8.21 2670 526 2.85 / 1570.68 3 3
6 13 1021.88 40 8.33 2584 861 3.72 / 1571.54 3 3
7 13 344.36 40 9.48 1640 622 4.34 / 1572.17 3 3
8 8 0.20 160 10.24 970 1589 5.93 / 1573.75 3 4
Average= 5.96 (KJ/cycle)

Cycle 262 GMT 16/ 5/2023 10:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 39 10.20 1099 437 0.44 / 1559.67 3 3
2 10 1042.36 3 8.37 2664 67 0.50 / 1559.74 3 3
3 3 1075.12 2 8.24 2789 46 0.55 / 1559.78 3 3
4 3 1052.64 1 8.15 2805 23 0.57 / 1559.81 3 3
5 12 1158.76 6 7.94 2862 136 0.71 / 1559.94 3 3
6 12 2000.80 85 6.78 3653 2105 2.81 / 1562.05 3 3
7 7 1996.12 24 6.62 3769 599 3.41 / 1562.65 3 3
8 13 1872.48 40 7.05 3634 1025 4.44 / 1563.67 3 3
9 13 1595.84 40 7.35 3363 989 5.43 / 1564.66 3 3
10 13 1040.68 40 8.14 2715 884 6.31 / 1565.54 3 3
11 13 359.88 40 9.45 1717 649 6.96 / 1566.19 3 3
12 8 0.00 160 10.23 999 1635 8.59 / 1567.83 3 4
Average= 5.96 (KJ/cycle)

Cycle 261 GMT 15/ 5/2023 8:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 35 10.22 1129 404 0.40 / 1552.49 3 3
2 10 1035.08 4 8.56 2731 94 0.50 / 1552.59 3 3
3 10 1067.12 3 8.49 2783 71 0.57 / 1552.66 3 3
4 3 1100.32 3 8.37 2840 71 0.64 / 1552.73 3 3
5 3 1097.16 2 8.44 2812 47 0.69 / 1552.78 3 3
6 12 1205.80 85 7.83 2822 1878 2.57 / 1554.66 3 3
7 7 1204.20 24 7.49 3107 559 3.12 / 1555.21 3 3
8 13 1093.48 40 7.57 3226 977 4.10 / 1556.19 3 3
9 13 829.28 40 8.53 2403 820 4.92 / 1557.01 3 3
10 13 24.84 40 9.83 1372 539 5.46 / 1557.55 3 3
11 8 0.16 160 10.16 1035 1682 7.14 / 1559.23 3 6
Average= 5.95 (KJ/cycle)

Cycle 260 GMT 5/ 5/2023 16:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 41 10.48 1074 461 0.46 / 1546.04 3 3
2 10 1022.56 3 8.16 3581 88 0.55 / 1546.13 3 3
3 12 1167.16 85 8.19 2731 1901 2.45 / 1548.03 3 3
4 7 1164.80 24 8.12 2947 574 3.02 / 1548.60 3 3
5 13 1050.84 40 8.17 2924 956 3.98 / 1549.56 3 3
6 13 773.28 40 8.89 2334 830 4.81 / 1550.39 3 3
7 8 -0.04 160 10.27 1035 1701 6.51 / 1552.09 3 5
Average= 5.95 (KJ/cycle)

Cycle 259 GMT 25/ 4/2023 22:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 34 10.12 2077 715 0.71 / 1539.23 3 3
2 10 1019.36 3 9.51 3778 108 0.82 / 1539.34 3 3
3 3 1103.52 3 9.29 3943 110 0.93 / 1539.45 3 3
4 3 1063.68 2 9.22 3859 71 1.00 / 1539.52 3 3
5 12 1159.80 85 8.61 2831 2072 3.08 / 1541.59 3 3
6 7 1156.36 24 8.63 2759 571 3.65 / 1542.16 3 3
7 13 1023.40 40 8.63 2755 951 4.60 / 1543.11 3 3
8 13 448.96 40 9.61 1847 710 5.31 / 1543.82 3 3
9 8 0.24 160 10.39 1058 1759 7.07 / 1545.58 3 5
Average= 5.94 (KJ/cycle)

Cycle 258 GMT 16/ 4/2023 5:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 31 11.23 1110 386 0.39 / 1530.20 3 3
2 10 1016.20 4 10.93 2932 128 0.51 / 1530.32 3 3
3 10 1048.56 3 10.90 2940 96 0.61 / 1530.42 3 3
4 3 1083.36 2 10.53 3074 65 0.68 / 1530.48 3 3
5 3 1036.96 1 10.51 3039 32 0.71 / 1530.52 3 3
6 12 1146.64 6 10.35 2928 182 0.89 / 1530.70 3 3
7 12 1995.32 85 8.26 3801 2669 3.56 / 1533.37 3 3
8 7 1988.64 24 7.87 3929 742 4.30 / 1534.11 3 3
9 13 1421.72 40 9.07 3293 1195 5.49 / 1535.30 3 3
10 13 718.40 40 9.92 2314 918 6.41 / 1536.22 3 3
11 13 23.68 40 11.04 1213 536 6.95 / 1536.76 3 4
12 8 -0.04 160 10.95 1002 1756 8.70 / 1538.51 3 6
Average= 5.94 (KJ/cycle)

Cycle 257 GMT 15/ 4/2023 2:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 31 12.40 951 366 0.37 / 1523.17 3 3
2 10 1029.96 4 11.72 2894 136 0.50 / 1523.31 3 3
3 3 1024.96 1 11.12 3197 36 0.54 / 1523.34 3 3
4 12 1147.00 85 7.12 2440 1477 2.01 / 1524.82 3 3
5 7 1146.64 24 8.17 3369 661 2.67 / 1525.48 3 3
6 13 1051.76 40 8.62 2785 960 3.63 / 1526.44 3 3
7 13 783.04 40 9.43 2570 969 4.60 / 1527.41 3 3
8 13 31.84 40 11.61 1224 568 5.17 / 1527.98 3 4
9 8 -0.04 160 11.22 1019 1829 7.00 / 1529.81 3 9
Average= 5.93 (KJ/cycle)

Cycle 256 GMT 5/ 4/2023 8:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 31 13.01 870 351 0.35 / 1516.96 3 5
2 10 1009.36 3 12.28 2797 103 0.45 / 1517.07 3 3
3 12 1153.92 85 8.05 2603 1781 2.24 / 1518.85 3 3
4 7 1152.28 24 9.75 2832 663 2.90 / 1519.51 3 3
5 13 1035.32 40 9.73 2599 1012 3.91 / 1520.52 3 3
6 13 304.44 40 11.89 1508 717 4.63 / 1521.24 3 4
7 8 0.08 160 12.23 802 1569 6.20 / 1522.81 3 11
Average= 5.93 (KJ/cycle)

Cycle 255 GMT 26/ 3/2023 14:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 30 13.48 886 358 0.36 / 1511.27 3 4
2 12 1131.24 85 9.10 2596 2008 2.37 / 1513.28 3 3
3 7 1127.60 25 10.18 2837 722 3.09 / 1514.00 3 3
4 13 860.04 40 10.92 2395 1046 4.13 / 1515.04 3 3
5 8 -0.12 160 12.77 767 1567 5.70 / 1516.61 3 16
Average= 5.92 (KJ/cycle)

Cycle 254 GMT 16/ 3/2023 20:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 31 13.68 849 360 0.36 / 1503.40 3 3
2 12 1116.68 6 11.84 2670 190 0.55 / 1503.59 3 3
3 12 1995.36 85 9.73 3755 3106 3.66 / 1506.69 3 3
4 7 1988.12 24 10.08 3967 960 4.61 / 1507.65 3 3
5 13 915.64 40 12.04 2427 1169 5.78 / 1508.82 3 5
6 13 24.72 40 13.56 1009 547 6.33 / 1509.37 3 10
7 8 0.12 160 13.06 738 1542 7.87 / 1510.91 3 17
Average= 5.93 (KJ/cycle)

Cycle 253 GMT 15/ 3/2023 18:11: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 31 13.67 895 379 0.38 / 1497.42 3 3
2 12 1143.36 85 7.56 2537 1630 2.01 / 1499.06 3 3
3 7 1142.20 24 10.04 2832 682 2.69 / 1499.74 3 3
4 13 1017.04 40 10.33 2568 1061 3.75 / 1500.80 3 3
5 13 294.40 40 13.10 1352 708 4.46 / 1501.51 3 8
6 8 0.00 160 13.24 722 1529 5.99 / 1503.04 3 17
Average= 5.92 (KJ/cycle)

Cycle 252 GMT 6/ 3/2023 0:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 30 13.88 894 372 0.37 / 1490.80 3 3
2 12 1143.96 85 8.42 2569 1839 2.21 / 1492.64 3 3
3 7 1140.72 24 10.19 2889 707 2.92 / 1493.34 3 3
4 13 1010.04 40 10.64 2598 1106 4.02 / 1494.45 3 3
5 13 26.32 40 13.63 1051 573 4.60 / 1495.02 3 9
6 8 0.08 160 12.69 996 2022 6.62 / 1497.05 3 13
Average= 5.92 (KJ/cycle)

Cycle 251 GMT 24/ 2/2023 6: 9: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 30 13.90 819 342 0.34 / 1484.58 3 3
2 12 1125.88 85 9.30 2587 2045 2.39 / 1486.62 3 3
3 7 1121.28 24 9.65 3752 869 3.26 / 1487.49 3 3
4 13 857.16 40 11.05 3062 1353 4.61 / 1488.84 3 4
5 8 0.24 160 13.40 739 1584 6.19 / 1490.43 3 9
Average= 5.91 (KJ/cycle)

Cycle 250 GMT 14/ 2/2023 12:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 31 13.79 823 352 0.35 / 1477.08 3 3
2 3 971.56 -1 15.10 0 0 0.00 / 1477.08 3 3
3 12 1147.52 6 11.93 2855 204 0.56 / 1477.29 3 3
4 12 2002.40 85 10.15 3773 3255 3.81 / 1480.54 3 3
5 7 1995.68 24 10.44 4012 1005 4.82 / 1481.55 3 3
6 13 747.32 40 12.64 2111 1067 5.88 / 1482.61 3 6
7 8 0.08 160 13.40 756 1621 7.50 / 1484.23 3 11
Average= 5.91 (KJ/cycle)

Cycle 249 GMT 13/ 2/2023 9:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 33 13.79 893 406 0.41 / 1469.58 3 3
2 3 907.96 -2 15.12 0 0 0.00 / 1469.58 3 3
3 12 1144.24 85 6.14 2705 1412 1.82 / 1470.99 3 3
4 7 1147.80 24 9.43 3522 797 2.62 / 1471.79 3 3
5 13 1112.96 40 10.24 2905 1190 3.81 / 1472.98 3 3
6 13 993.64 40 11.38 2518 1146 4.95 / 1474.12 3 4
7 13 43.80 40 13.77 967 533 5.48 / 1474.66 3 10
8 8 -0.08 160 13.28 976 2074 7.56 / 1476.73 3 10
Average= 5.91 (KJ/cycle)

Cycle 248 GMT 3/ 2/2023 15: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 30 13.84 938 389 0.39 / 1463.39 3 4
2 12 1141.40 85 7.33 2491 1552 1.94 / 1464.94 3 3
3 7 1140.56 24 9.69 3187 741 2.68 / 1465.68 3 3
4 13 1034.04 40 11.03 2575 1136 3.82 / 1466.81 3 3
5 13 305.08 40 13.31 1362 725 4.54 / 1467.54 3 7
6 8 -0.08 160 13.45 758 1631 6.18 / 1469.17 3 11
Average= 5.90 (KJ/cycle)

Cycle 247 GMT 24/ 1/2023 20:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 31 13.97 866 375 0.38 / 1457.62 3 3
2 12 1107.60 85 8.59 2514 1836 2.21 / 1459.46 3 3
3 7 1104.32 24 10.42 2807 702 2.91 / 1460.16 3 3
4 13 972.32 40 11.66 2487 1160 4.07 / 1461.32 3 3
5 8 0.04 160 13.43 779 1674 5.75 / 1463.00 3 8
Average= 5.90 (KJ/cycle)

Cycle 246 GMT 15/ 1/2023 3: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 33 13.91 855 392 0.39 / 1448.99 3 3
2 3 903.36 -2 15.11 0 0 0.00 / 1448.99 3 3
3 12 1136.84 6 11.58 2820 196 0.59 / 1449.18 3 3
4 12 1996.52 85 9.73 3796 3139 3.73 / 1452.32 3 3
5 7 1989.64 24 10.39 4001 998 4.73 / 1453.32 3 3
6 13 1056.12 40 12.30 2615 1287 6.01 / 1454.61 3 4
7 13 70.24 40 13.79 1039 573 6.59 / 1455.18 3 12
8 13 19.80 40 13.99 859 481 7.07 / 1455.66 3 10
9 8 -0.20 160 13.67 726 1588 8.65 / 1457.25 3 17
Average= 5.90 (KJ/cycle)

Cycle 245 GMT 14/ 1/2023 0:11: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 31 13.61 817 345 0.34 / 1442.77 3 4
2 3 1052.56 1 12.01 3101 37 0.38 / 1442.81 3 3
3 3 1029.72 1 11.32 3048 35 0.42 / 1442.84 3 3
4 12 1145.16 85 7.28 2478 1533 1.95 / 1444.38 3 3
5 7 1144.84 24 10.11 2905 705 2.65 / 1445.08 3 3
6 13 1045.56 40 11.44 2525 1155 3.81 / 1446.24 3 3
7 13 306.80 40 13.41 1371 735 4.55 / 1446.97 3 9
8 8 0.16 160 13.59 747 1624 6.17 / 1448.60 3 13
Average= 5.89 (KJ/cycle)

Cycle 244 GMT 4/ 1/2023 6: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 30 13.99 799 335 0.34 / 1435.30 3 4
2 3 1020.88 1 10.40 4117 43 0.38 / 1435.35 3 3
3 3 1020.60 1 10.52 3700 39 0.42 / 1435.38 3 3
4 12 1154.20 85 6.62 2781 1565 1.98 / 1436.95 3 3
5 7 1156.28 24 8.81 4238 896 2.88 / 1437.85 3 3
6 13 1084.48 40 10.34 3408 1410 4.29 / 1439.26 3 3
7 13 953.24 40 11.58 2725 1262 5.55 / 1440.52 3 4
8 8 0.20 160 13.48 885 1909 7.46 / 1442.43 3 15
Average= 5.89 (KJ/cycle)

Cycle 243 GMT 25/12/2022 12: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 30 14.03 772 325 0.32 / 1428.53 3 4
2 3 973.56 -1 15.07 1 0 0.00 / 1428.53 3 4
3 12 1164.52 85 7.63 2963 1922 2.25 / 1430.45 3 3
4 7 1163.52 24 9.75 3670 859 3.11 / 1431.31 3 3
5 13 1052.32 40 11.29 2953 1334 4.44 / 1432.65 3 3
6 13 295.64 40 13.52 1328 718 5.16 / 1433.37 3 8
7 8 -0.16 160 13.68 732 1602 6.76 / 1434.97 3 15
Average= 5.88 (KJ/cycle)

Cycle 242 GMT 15/12/2022 18: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 31 12.95 1780 715 0.71 / 1419.31 3 6
2 3 1076.84 2 10.91 4885 107 0.82 / 1419.41 3 3
3 3 1035.48 1 11.18 4468 50 0.87 / 1419.46 3 3
4 12 1141.40 6 10.67 4378 280 1.15 / 1419.74 3 3
5 12 1997.36 85 9.15 4343 3378 4.53 / 1423.12 3 3
6 7 1991.16 24 10.27 4547 1121 5.65 / 1424.24 3 3
7 13 1220.56 40 11.64 3586 1670 7.32 / 1425.91 3 4
8 13 74.92 40 13.54 1303 706 8.03 / 1426.62 3 10
9 8 0.00 160 13.74 723 1589 9.61 / 1428.21 3 14
Average= 5.88 (KJ/cycle)

Cycle 241 GMT 14/12/2022 15:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 30 13.95 849 355 0.36 / 1412.98 3 4
2 3 1030.40 1 11.33 3411 39 0.39 / 1413.02 3 3
3 3 1019.12 1 10.82 2884 31 0.43 / 1413.05 3 3
4 12 1151.40 85 7.12 2420 1465 1.89 / 1414.51 3 3
5 7 1152.28 24 10.13 2842 691 2.58 / 1415.20 3 3
6 13 1053.40 40 11.64 2467 1149 3.73 / 1416.35 3 3
7 13 209.24 40 13.63 1205 657 4.39 / 1417.01 3 8
8 8 0.00 160 13.74 721 1585 5.97 / 1418.59 3 13
Average= 5.86 (KJ/cycle)

Cycle 240 GMT 4/12/2022 21: 9: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 30 13.88 904 376 0.38 / 1406.86 3 5
2 12 1154.96 85 7.35 2524 1577 1.95 / 1408.43 3 3
3 7 1154.40 24 10.21 2865 702 2.66 / 1409.14 3 3
4 13 1043.52 40 11.77 2478 1167 3.82 / 1410.30 3 4
5 13 296.28 40 13.57 1270 689 4.51 / 1410.99 3 12
6 8 0.00 160 13.71 743 1630 6.14 / 1412.62 3 18
Average= 5.86 (KJ/cycle)

Cycle 239 GMT 25/11/2022 3: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 30 13.97 844 354 0.35 / 1401.11 3 3
2 12 1142.84 85 8.57 2553 1860 2.21 / 1402.97 3 3
3 7 1139.56 24 10.55 2831 717 2.93 / 1403.68 3 3
4 13 1005.96 40 12.20 2359 1151 4.08 / 1404.84 3 4
5 8 0.24 160 13.69 751 1645 5.73 / 1406.48 3 13
Average= 5.86 (KJ/cycle)

Cycle 238 GMT 15/11/2022 9:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 30 13.85 913 379 0.38 / 1393.61 3 5
2 3 1025.12 1 11.49 3116 36 0.42 / 1393.65 3 3
3 12 1134.60 6 11.89 2613 186 0.60 / 1393.83 3 3
4 12 1997.76 85 9.76 3728 3093 3.69 / 1396.93 3 3
5 7 1990.68 25 10.45 4059 1060 4.75 / 1397.99 3 3
6 13 910.48 40 12.74 2265 1154 5.91 / 1399.14 3 7
7 8 0.28 160 13.73 735 1615 7.52 / 1400.75 3 14
Average= 5.86 (KJ/cycle)

Cycle 237 GMT 14/11/2022 6:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 30 13.94 840 351 0.35 / 1387.62 3 3
2 12 1124.00 85 7.03 2485 1485 1.84 / 1389.10 3 3
3 7 1124.64 24 10.36 2788 693 2.53 / 1389.79 3 3
4 13 1028.20 40 11.94 2386 1140 3.67 / 1390.93 3 3
5 13 295.60 40 13.56 1251 679 4.35 / 1391.61 3 19
6 8 0.12 160 13.74 736 1618 5.97 / 1393.23 3 16
Average= 5.85 (KJ/cycle)

Cycle 236 GMT 4/11/2022 12:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 30 13.95 829 347 0.35 / 1381.72 3 5
2 12 1143.36 85 7.63 2541 1648 1.99 / 1383.36 3 3
3 7 1142.36 24 10.39 2880 718 2.71 / 1384.08 3 3
4 13 1032.28 40 12.06 2395 1155 3.87 / 1385.24 3 4
5 13 66.76 40 13.90 888 494 4.36 / 1385.73 3 10
6 8 0.12 160 13.83 693 1533 5.90 / 1387.27 3 14
Average= 5.85 (KJ/cycle)

Cycle 235 GMT 25/10/2022 18:14: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 30 13.93 857 358 0.36 / 1376.11 3 6
2 12 1132.92 85 8.95 2510 1909 2.27 / 1378.02 3 3
3 7 1128.92 24 10.65 2797 715 2.98 / 1378.74 3 3
4 13 858.28 40 12.70 2102 1068 4.05 / 1379.81 3 5
5 8 0.28 160 13.79 709 1564 5.61 / 1381.37 3 12
Average= 5.85 (KJ/cycle)

Cycle 234 GMT 16/10/2022 0:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 30 13.92 801 334 0.33 / 1368.77 3 3
2 12 1128.40 6 11.89 2487 177 0.51 / 1368.95 3 3
3 12 1996.48 85 9.94 3660 3092 3.60 / 1372.04 3 3
4 7 1989.24 24 10.58 3931 998 4.60 / 1373.04 3 3
5 13 896.84 40 12.83 2211 1135 5.74 / 1374.17 3 6
6 8 0.08 160 13.78 717 1581 7.32 / 1375.76 3 13
Average= 5.85 (KJ/cycle)

Cycle 233 GMT 14/10/2022 21:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 29 13.95 785 318 0.32 / 1362.93 3 3
2 12 1143.24 85 6.86 2459 1434 1.75 / 1364.37 3 3
3 7 1144.52 24 10.50 2759 695 2.45 / 1365.06 3 3
4 13 1052.44 40 12.14 2383 1157 3.60 / 1366.22 3 4
5 13 327.88 40 13.60 1245 677 4.28 / 1366.89 3 9
6 8 0.12 160 13.81 698 1542 5.82 / 1368.44 3 13
Average= 5.85 (KJ/cycle)

Cycle 232 GMT 5/10/2022 3:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 30 13.96 784 328 0.33 / 1356.36 3 4
2 12 1129.72 85 6.73 2777 1589 1.92 / 1357.94 3 3
3 7 1131.44 24 10.13 3505 852 2.77 / 1358.80 3 3
4 13 1051.36 40 11.30 3217 1454 4.22 / 1360.25 3 3
5 13 378.24 40 13.38 1547 828 5.05 / 1361.08 3 13
6 8 0.04 160 13.83 694 1536 6.59 / 1362.61 3 11
Average= 5.85 (KJ/cycle)

Cycle 231 GMT 25/ 9/2022 9: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 30 13.94 829 347 0.35 / 1350.76 3 3
2 12 1118.72 85 8.61 2496 1827 2.17 / 1352.59 3 3
3 7 1116.12 24 10.60 2849 725 2.90 / 1353.31 3 3
4 13 986.36 40 12.36 2316 1145 4.04 / 1354.46 3 3
5 8 0.44 160 13.79 711 1569 5.61 / 1356.03 3 15
Average= 5.84 (KJ/cycle)

Cycle 230 GMT 15/ 9/2022 15:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 30 13.93 826 345 0.35 / 1342.68 3 3
2 12 1114.96 6 12.05 2481 179 0.52 / 1342.86 3 3
3 12 1998.32 85 9.73 3828 3166 3.69 / 1346.02 3 3
4 7 1991.16 24 10.13 4770 1160 4.85 / 1347.18 3 3
5 13 919.72 40 12.07 3234 1561 6.41 / 1348.74 3 4
6 8 -0.12 160 13.72 762 1673 8.08 / 1350.41 3 13
Average= 5.85 (KJ/cycle)

Cycle 229 GMT 14/ 9/2022 11:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 30 13.90 824 344 0.34 / 1336.79 3 3
2 3 954.80 -1 15.11 0 0 0.00 / 1336.79 3 3
3 12 1140.20 85 6.90 2443 1433 1.78 / 1338.23 3 3
4 7 1141.32 24 10.02 3237 778 2.55 / 1339.00 3 3
5 13 1053.00 40 12.13 2411 1170 3.72 / 1340.17 3 4
6 13 201.12 40 13.74 1064 585 4.31 / 1340.76 3 7
7 8 0.04 160 13.80 712 1572 5.88 / 1342.33 3 16
Average= 5.84 (KJ/cycle)

Cycle 228 GMT 4/ 9/2022 17:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 30 13.77 814 336 0.34 / 1330.80 3 5
2 12 1147.40 85 7.28 2469 1528 1.86 / 1332.33 3 3
3 7 1147.04 24 9.81 3683 867 2.73 / 1333.20 3 3
4 13 1052.88 40 12.24 2370 1160 3.89 / 1334.36 3 5
5 13 196.08 40 13.75 1074 591 4.48 / 1334.95 3 8
6 8 -0.04 160 13.84 677 1499 5.98 / 1336.45 3 11
Average= 5.84 (KJ/cycle)

Cycle 227 GMT 25/ 8/2022 23:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 30 13.91 799 333 0.33 / 1325.08 3 7
2 12 1140.56 85 8.67 2522 1859 2.19 / 1326.94 3 3
3 7 1137.56 24 10.74 2797 721 2.91 / 1327.66 3 3
4 13 1009.56 40 12.45 2307 1149 4.06 / 1328.81 3 5
5 8 0.32 160 13.71 757 1661 5.72 / 1330.47 3 17
Average= 5.84 (KJ/cycle)

Cycle 226 GMT 16/ 8/2022 5:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 30 13.92 807 337 0.34 / 1317.76 3 3
2 12 1109.84 6 11.90 2504 179 0.52 / 1317.93 3 3
3 12 1998.28 85 9.72 3895 3218 3.73 / 1321.15 3 3
4 7 1991.24 24 10.71 3879 997 4.73 / 1322.15 3 3
5 13 903.00 40 12.94 2110 1092 5.82 / 1323.24 3 7
6 8 0.04 160 13.84 679 1504 7.33 / 1324.75 3 11
Average= 5.84 (KJ/cycle)

Cycle 225 GMT 15/ 8/2022 2:23: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 30 13.86 841 350 0.35 / 1311.93 3 6
2 12 1133.56 85 7.17 2406 1466 1.82 / 1313.40 3 3
3 7 1133.64 24 10.55 2781 704 2.52 / 1314.10 3 3
4 13 1034.48 40 12.29 2402 1181 3.70 / 1315.28 3 4
5 13 146.08 40 13.75 1027 565 4.27 / 1315.85 3 13
6 8 -0.12 160 13.73 716 1573 5.84 / 1317.42 3 14
Average= 5.83 (KJ/cycle)

Cycle 224 GMT 5/ 8/2022 8:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 30 13.94 764 320 0.32 / 1306.49 3 5
2 3 973.48 -1 15.11 0 0 0.00 / 1306.49 3 5
3 3 1026.08 1 11.39 2960 34 0.35 / 1306.53 3 3
4 12 1151.64 85 7.92 2481 1670 2.02 / 1308.20 3 3
5 7 1149.88 24 10.72 2843 731 2.75 / 1308.93 3 3
6 13 1025.08 40 12.56 2274 1142 3.90 / 1310.07 3 5
7 8 0.20 160 13.84 682 1510 5.41 / 1311.58 3 12
Average= 5.83 (KJ/cycle)

Cycle 223 GMT 26/ 7/2022 14:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 30 13.86 829 345 0.34 / 1300.37 3 4
2 12 1120.28 85 9.15 2545 1979 2.32 / 1302.35 3 3
3 7 1116.48 24 10.35 3584 890 3.21 / 1303.24 3 3
4 13 855.88 40 12.45 2495 1243 4.46 / 1304.48 3 5
5 8 0.08 160 13.66 773 1689 6.15 / 1306.17 3 13
Average= 5.83 (KJ/cycle)

Cycle 222 GMT 16/ 7/2022 20:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 30 13.83 832 345 0.35 / 1293.07 3 5
2 3 970.76 -1 15.16 1 0 0.00 / 1293.07 3 5
3 3 1026.32 1 11.04 2933 32 0.38 / 1293.10 3 3
4 12 1142.84 6 11.87 2605 186 0.56 / 1293.29 3 3
5 12 1996.00 85 10.03 3698 3153 3.72 / 1296.44 3 3
6 7 1988.60 24 10.60 3928 999 4.72 / 1297.44 3 3
7 13 876.44 40 12.95 2105 1090 5.81 / 1298.53 3 9
8 8 0.16 160 13.85 675 1496 7.30 / 1300.03 3 11
Average= 5.83 (KJ/cycle)

Cycle 221 GMT 15/ 7/2022 17:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 30 13.93 820 343 0.34 / 1287.40 3 5
2 12 1143.32 85 7.12 2420 1465 1.81 / 1288.86 3 3
3 7 1144.00 24 10.69 2832 727 2.53 / 1289.59 3 3
4 13 1042.68 40 12.44 2343 1166 3.70 / 1290.75 3 5
5 13 75.28 40 13.88 885 491 4.19 / 1291.24 3 13
6 8 0.08 160 13.85 668 1480 5.67 / 1292.72 3 22
Average= 5.82 (KJ/cycle)

Cycle 220 GMT 5/ 7/2022 23:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 29 13.82 894 358 0.36 / 1281.86 3 5
2 3 1032.40 1 11.99 2995 36 0.39 / 1281.90 3 3
3 12 1145.32 85 8.14 2465 1706 2.10 / 1283.60 3 3
4 7 1142.84 24 10.80 2800 726 2.83 / 1284.33 3 3
5 13 1016.84 40 12.50 2343 1171 4.00 / 1285.50 3 5
6 8 0.16 160 13.81 704 1556 5.55 / 1287.05 3 12
Average= 5.82 (KJ/cycle)

Cycle 219 GMT 26/ 6/2022 5:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 30 13.99 778 327 0.33 / 1276.30 3 3
2 3 942.24 -1 15.17 0 0 0.00 / 1276.30 3 3
3 12 1122.12 85 9.18 2503 1953 2.28 / 1278.26 3 3
4 7 1118.40 24 10.97 2764 728 3.01 / 1278.98 3 3
5 13 722.56 40 13.11 1861 976 3.98 / 1279.96 3 6
6 8 0.36 160 13.82 697 1541 5.52 / 1281.50 3 14
Average= 5.83 (KJ/cycle)

Cycle 218 GMT 16/ 6/2022 11:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 30 13.92 794 332 0.33 / 1268.44 3 4
2 12 1129.92 6 12.02 2455 177 0.51 / 1268.61 3 3
3 12 1996.00 85 10.03 3661 3121 3.63 / 1271.73 3 3
4 7 1988.68 24 10.70 3869 994 4.62 / 1272.73 3 3
5 13 888.44 40 12.54 2586 1297 5.92 / 1274.02 3 7
6 13 47.12 40 13.84 999 553 6.47 / 1274.58 3 10
7 8 0.00 160 13.94 627 1398 7.87 / 1275.98 3 9
Average= 5.83 (KJ/cycle)

Cycle 217 GMT 15/ 6/2022 8:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 30 13.95 764 320 0.32 / 1262.90 3 3
2 12 1124.44 85 7.64 2595 1685 2.00 / 1264.58 3 3
3 7 1123.96 24 10.31 3640 901 2.91 / 1265.48 3 3
4 13 1018.36 40 12.62 2274 1148 4.05 / 1266.63 3 4
5 8 0.12 160 13.92 661 1472 5.53 / 1268.10 3 11
Average= 5.82 (KJ/cycle)

Cycle 216 GMT 5/ 6/2022 14:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 30 13.85 888 369 0.37 / 1257.53 3 3
2 12 1125.96 85 9.03 2439 1872 2.24 / 1259.40 3 3
3 7 1122.00 24 11.05 2646 702 2.94 / 1260.10 3 3
4 13 729.44 40 13.08 1866 976 3.92 / 1261.08 3 5
5 8 0.08 160 13.87 677 1502 5.42 / 1262.58 3 13
Average= 5.82 (KJ/cycle)

Cycle 215 GMT 26/ 5/2022 20:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 30 13.97 784 329 0.33 / 1252.02 3 3
2 12 1138.24 85 9.72 2540 2099 2.43 / 1254.11 3 3
3 7 1133.76 24 11.06 2640 701 3.13 / 1254.82 3 3
4 13 590.68 40 13.32 1636 872 4.00 / 1255.69 3 8
5 8 0.12 160 13.90 661 1470 5.47 / 1257.16 3 12
Average= 5.82 (KJ/cycle)

Cycle 214 GMT 17/ 5/2022 2:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 31 13.98 780 338 0.34 / 1244.78 3 3
2 3 962.12 -1 15.20 0 0 0.00 / 1244.78 3 3
3 12 1126.12 6 12.00 2551 184 0.52 / 1244.97 3 3
4 12 1996.04 85 10.13 3688 3176 3.70 / 1248.14 3 3
5 7 1988.48 24 10.69 3885 997 4.69 / 1249.14 3 3
6 13 873.00 40 12.97 2123 1101 5.80 / 1250.24 3 7
7 8 0.24 160 13.93 650 1449 7.24 / 1251.69 3 13
Average= 5.82 (KJ/cycle)

Cycle 213 GMT 16/ 5/2022 0: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 31 13.94 748 323 0.32 / 1238.86 3 3
2 12 1127.40 85 7.40 2564 1613 1.94 / 1240.47 3 3
3 7 1128.92 24 10.94 2746 721 2.66 / 1241.19 3 3
4 13 1033.00 40 12.55 2348 1179 3.84 / 1242.37 3 4
5 13 147.00 40 13.77 1037 571 4.41 / 1242.94 3 11
6 8 -0.04 160 13.85 679 1505 5.91 / 1244.44 3 13
Average= 5.82 (KJ/cycle)

Cycle 212 GMT 6/ 5/2022 6: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 30 13.95 757 317 0.32 / 1232.96 3 3
2 3 971.88 -1 15.20 1 0 0.00 / 1232.96 3 3
3 3 1022.24 1 10.91 3072 34 0.35 / 1233.00 3 3
4 12 1163.20 85 7.96 2499 1691 2.04 / 1234.69 3 3
5 7 1162.12 24 10.79 2949 764 2.80 / 1235.45 3 3
6 13 1039.08 40 12.55 2388 1199 4.00 / 1236.65 3 5
7 13 50.68 40 13.91 808 450 4.45 / 1237.10 3 6
8 8 0.04 160 13.91 644 1433 5.89 / 1238.53 3 10
Average= 5.81 (KJ/cycle)

Cycle 211 GMT 26/ 4/2022 12: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 30 14.02 752 316 0.32 / 1227.36 3 3
2 12 1150.64 85 9.07 2602 2006 2.32 / 1229.37 3 3
3 7 1147.04 24 11.15 2790 747 3.07 / 1230.11 3 3
4 13 873.76 40 12.94 2117 1096 4.16 / 1231.21 3 7
5 8 -0.32 160 13.91 645 1436 5.60 / 1232.65 3 15
Average= 5.81 (KJ/cycle)

Cycle 210 GMT 16/ 4/2022 18:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 30 13.93 785 328 0.33 / 1220.02 3 3
2 3 1029.88 1 11.26 3350 38 0.37 / 1220.05 3 3
3 12 1135.08 6 12.04 2567 185 0.55 / 1220.24 3 3
4 12 1995.84 85 9.98 3730 3164 3.72 / 1223.40 3 3
5 7 1988.48 24 10.63 4010 1023 4.74 / 1224.43 3 3
6 13 1019.24 40 12.77 2345 1198 5.94 / 1225.62 3 5
7 8 0.04 160 13.94 637 1421 7.36 / 1227.05 3 8
Average= 5.82 (KJ/cycle)

Cycle 209 GMT 15/ 4/2022 15:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 31 13.96 816 353 0.35 / 1214.05 3 3
2 12 1120.60 85 7.97 2477 1678 2.03 / 1215.73 3 3
3 7 1119.40 24 10.95 2798 735 2.77 / 1216.47 3 3
4 13 997.64 40 12.28 2583 1269 4.04 / 1217.73 3 4
5 13 50.20 40 13.87 863 479 4.51 / 1218.21 3 7
6 8 0.12 160 13.88 664 1475 5.99 / 1219.69 3 11
Average= 5.81 (KJ/cycle)

Cycle 208 GMT 5/ 4/2022 21:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 30 13.93 807 337 0.34 / 1208.24 3 3
2 12 1132.92 85 8.90 2554 1932 2.27 / 1210.17 3 3
3 7 1129.36 24 10.88 2916 761 3.03 / 1210.93 3 3
4 13 998.20 40 12.56 2326 1169 4.20 / 1212.10 3 4
5 8 0.12 160 13.79 724 1597 5.80 / 1213.70 3 14
Average= 5.81 (KJ/cycle)

Cycle 207 GMT 27/ 3/2022 3:46: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 30 13.93 986 412 0.41 / 1202.67 3 3
2 12 1129.28 85 9.45 2483 1994 2.41 / 1204.66 3 3
3 7 1125.08 24 11.06 2788 740 3.15 / 1205.40 3 3
4 13 724.08 40 13.09 1879 984 4.13 / 1206.39 3 7
5 8 0.40 160 13.84 685 1517 5.65 / 1207.90 3 12
Average= 5.81 (KJ/cycle)

Cycle 206 GMT 17/ 3/2022 9:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 29 13.95 717 290 0.29 / 1195.32 3 3
2 12 1127.36 6 12.24 2407 177 0.47 / 1195.49 3 3
3 12 1994.24 85 10.05 3666 3132 3.60 / 1198.63 3 3
4 7 1986.84 24 10.59 4084 1038 4.64 / 1199.66 3 3
5 13 875.88 40 12.93 2120 1096 5.73 / 1200.76 3 8
6 8 0.08 160 13.87 674 1496 7.23 / 1202.26 3 9
Average= 5.81 (KJ/cycle)

Cycle 205 GMT 16/ 3/2022 6:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 30 13.78 838 346 0.35 / 1189.55 3 3
2 3 1039.80 1 12.23 2852 35 0.38 / 1189.59 3 3
3 12 1150.92 85 8.06 2452 1680 2.06 / 1191.27 3 3
4 7 1149.12 24 10.90 2818 737 2.80 / 1192.00 3 3
5 13 1020.48 40 12.56 2329 1170 3.97 / 1193.17 3 5
6 13 47.60 40 13.89 805 447 4.42 / 1193.62 3 8
7 8 -0.16 160 13.88 633 1406 5.82 / 1195.03 3 12
Average= 5.80 (KJ/cycle)

Cycle 204 GMT 6/ 3/2022 12:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 30 13.97 764 320 0.32 / 1183.57 3 3
2 12 1139.40 85 8.68 2605 1922 2.24 / 1185.49 3 3
3 7 1135.80 24 11.08 2782 740 2.98 / 1186.23 3 3
4 13 873.08 40 12.86 2099 1080 4.06 / 1187.31 3 6
5 13 17.16 40 13.94 773 431 4.49 / 1187.74 3 7
6 8 0.04 160 13.87 659 1462 5.96 / 1189.21 3 14
Average= 5.80 (KJ/cycle)

Cycle 203 GMT 24/ 2/2022 19: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 30 13.99 742 311 0.31 / 1178.04 3 3
2 12 1137.20 85 9.74 2486 2058 2.37 / 1180.10 3 3
3 7 1132.36 24 11.13 2734 730 3.10 / 1180.83 3 3
4 13 710.56 40 13.09 1849 968 4.07 / 1181.80 3 8
5 8 -0.08 160 13.86 654 1450 5.52 / 1183.25 3 13
Average= 5.80 (KJ/cycle)

Cycle 202 GMT 15/ 2/2022 1:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 30 13.96 748 313 0.31 / 1170.83 3 3
2 12 1108.60 6 12.39 2422 180 0.49 / 1171.01 3 3
3 12 1993.36 85 10.02 3747 3191 3.68 / 1174.20 3 3
4 7 1986.00 24 10.67 3962 1015 4.70 / 1175.21 3 3
5 13 872.32 40 12.93 2085 1078 5.78 / 1176.29 3 6
6 8 0.04 160 13.90 648 1441 7.22 / 1177.73 3 12
Average= 5.80 (KJ/cycle)

Cycle 201 GMT 13/ 2/2022 21:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 30 13.93 732 306 0.31 / 1164.88 3 3
2 12 1119.32 85 7.88 2820 1889 2.19 / 1166.77 3 3
3 7 1117.72 24 11.28 2573 697 2.89 / 1167.47 3 4
4 13 995.16 40 12.74 2223 1133 4.02 / 1168.60 3 6
5 13 43.40 40 13.89 797 443 4.47 / 1169.04 3 9
6 8 0.32 160 13.86 664 1472 5.94 / 1170.51 3 14
Average= 5.79 (KJ/cycle)

Cycle 200 GMT 4/ 2/2022 4: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 30 13.93 772 323 0.32 / 1158.97 3 3
2 12 1125.88 78 9.32 2536 1844 2.17 / 1160.81 3 3
3 7 1122.76 24 10.96 2834 745 2.91 / 1161.56 3 3
4 13 869.20 40 12.80 2127 1089 4.00 / 1162.65 3 6
5 13 31.44 40 13.90 772 429 4.43 / 1163.07 3 9
6 8 -0.16 160 13.82 678 1499 5.93 / 1164.57 3 14
Average= 5.79 (KJ/cycle)

Cycle 199 GMT 25/ 1/2022 10:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 28 14.01 712 279 0.28 / 1153.67 3 3
2 3 1049.28 1 12.78 2523 32 0.31 / 1153.70 3 3
3 3 1022.56 1 11.55 2631 30 0.34 / 1153.73 3 3
4 12 1137.12 78 9.67 2418 1824 2.17 / 1155.55 3 3
5 7 1133.60 24 11.18 2651 711 2.88 / 1156.26 3 3
6 13 733.32 40 13.07 1852 968 3.85 / 1157.23 3 6
7 8 -0.16 160 13.88 636 1412 5.26 / 1158.64 3 13
Average= 5.79 (KJ/cycle)

Cycle 198 GMT 15/ 1/2022 16:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 28 13.97 699 273 0.27 / 1146.81 3 3
2 3 1027.00 1 11.88 3119 37 0.31 / 1146.85 3 3
3 3 1021.20 1 11.10 2770 31 0.34 / 1146.88 3 3
4 12 1135.32 6 12.40 2449 182 0.52 / 1147.06 3 3
5 12 1995.44 78 10.24 3608 2882 3.41 / 1149.94 3 3
6 7 1988.40 24 10.76 3808 983 4.39 / 1150.92 3 3
7 13 887.68 40 12.91 2060 1064 5.45 / 1151.99 3 6
8 8 0.12 160 13.94 627 1398 6.85 / 1153.39 3 14
Average= 5.80 (KJ/cycle)

Cycle 197 GMT 14/ 1/2022 12:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 29 13.96 719 291 0.29 / 1141.23 3 3
2 3 1023.20 1 11.91 3168 38 0.33 / 1141.27 3 3
3 12 1140.28 78 8.72 2451 1667 2.00 / 1142.94 3 3
4 7 1138.16 24 11.08 2672 711 2.71 / 1143.65 3 4
5 13 1007.88 40 12.64 2223 1124 3.83 / 1144.77 3 5
6 13 18.76 40 13.93 739 412 4.24 / 1145.18 3 9
7 8 -0.28 160 13.91 608 1353 5.60 / 1146.54 3 13
Average= 5.79 (KJ/cycle)

Cycle 196 GMT 4/ 1/2022 19: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 28 13.94 724 283 0.28 / 1135.95 3 3
2 12 1146.84 78 9.44 2517 1853 2.14 / 1137.80 3 3
3 7 1142.64 24 11.07 2749 730 2.87 / 1138.54 3 3
4 13 744.40 40 12.91 1956 1010 3.88 / 1139.55 3 7
5 8 -0.04 160 13.89 628 1396 5.27 / 1140.94 3 11
Average= 5.79 (KJ/cycle)

Cycle 195 GMT 26/12/2021 1: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 30 13.90 751 313 0.31 / 1130.68 3 3
2 3 953.48 -1 15.22 1 0 0.00 / 1130.68 3 3
3 12 1131.20 58 9.90 2494 1432 1.75 / 1132.11 3 3
4 7 1129.76 24 11.27 2675 724 2.47 / 1132.84 3 4
5 13 1003.36 37 12.71 2236 1052 3.52 / 1133.89 3 4
6 13 54.32 37 13.88 794 408 3.93 / 1134.30 3 13
7 8 -0.04 160 13.88 618 1372 5.30 / 1135.67 3 9
Average= 5.79 (KJ/cycle)

Cycle 194 GMT 16/12/2021 7: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 30 13.93 734 307 0.31 / 1124.01 3 3
2 3 946.48 -1 15.23 0 0 0.00 / 1124.01 3 3
3 12 1118.04 6 12.37 2456 182 0.49 / 1124.19 3 3
4 12 1986.12 58 10.38 3618 2178 2.67 / 1126.37 3 3
5 7 1980.16 24 10.78 3754 971 3.64 / 1127.34 3 3
6 13 1219.96 37 12.58 2587 1204 4.84 / 1128.54 3 5
7 13 136.16 37 13.81 904 462 5.30 / 1129.01 3 19
8 8 -0.04 160 13.91 612 1362 6.67 / 1130.37 3 18
Average= 5.80 (KJ/cycle)

Cycle 193 GMT 15/12/2021 2:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 30 13.89 751 313 0.31 / 1118.41 3 3
2 3 945.24 -1 15.23 0 0 0.00 / 1118.41 3 3
3 12 1117.04 58 9.03 2548 1334 1.65 / 1119.74 3 3
4 7 1116.72 24 11.20 2646 711 2.36 / 1120.46 3 3
5 13 1005.48 37 12.56 2265 1053 3.41 / 1121.51 3 5
6 13 264.36 37 13.59 1104 555 3.97 / 1122.06 3 17
7 8 -0.08 160 13.69 748 1638 5.60 / 1123.70 3 12
Average= 5.79 (KJ/cycle)

Cycle 192 GMT 5/12/2021 8:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 30 13.90 780 325 0.33 / 1113.10 3 3
2 12 1118.64 58 9.49 2556 1407 1.73 / 1114.51 3 3
3 7 1117.76 24 11.17 2669 716 2.45 / 1115.22 3 4
4 13 1002.56 37 12.54 2263 1050 3.50 / 1116.27 3 5
5 13 60.16 37 13.84 807 413 3.91 / 1116.69 3 11
6 8 0.00 160 13.81 639 1412 5.32 / 1118.10 3 16
Average= 5.79 (KJ/cycle)

Cycle 191 GMT 25/11/2021 14:51: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 30 13.95 766 321 0.32 / 1108.33 3 3
2 12 1098.36 58 10.41 2399 1448 1.77 / 1109.78 3 3
3 7 1096.08 24 11.40 2419 662 2.43 / 1110.44 3 4
4 13 840.92 37 12.86 1997 950 3.38 / 1111.39 3 7
5 8 0.16 160 13.85 624 1383 4.76 / 1112.77 3 14
Average= 5.80 (KJ/cycle)

Cycle 190 GMT 15/11/2021 20:51: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 23 13.96 726 233 0.23 / 1101.31 3 4
2 10 1005.48 4 13.22 2224 118 0.35 / 1101.43 3 3
3 10 1038.84 3 13.30 2233 89 0.44 / 1101.52 3 3
4 3 1029.32 1 12.02 2465 30 0.47 / 1101.55 3 3
5 12 1137.00 5 12.64 2406 152 0.62 / 1101.70 3 3
6 12 1999.72 58 10.74 3582 2231 2.85 / 1103.93 3 3
7 7 1993.36 24 10.97 3723 980 3.83 / 1104.91 3 3
8 13 1255.08 37 12.62 2614 1221 5.05 / 1106.13 3 5
9 13 174.12 37 13.81 962 492 5.55 / 1106.62 3 8
10 8 -0.16 160 13.94 622 1387 6.93 / 1108.01 3 10
Average= 5.80 (KJ/cycle)

Cycle 189 GMT 14/11/2021 17:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 31 13.95 726 314 0.31 / 1093.42 3 4
2 3 959.40 -1 15.33 0 0 0.00 / 1093.42 3 4
3 12 1131.48 10 9.30 2627 244 0.56 / 1093.66 3 3
4 12 2002.48 60 7.39 3557 1577 2.14 / 1095.24 3 3
5 12 1993.76 58 7.48 3631 1575 3.71 / 1096.82 3 3
6 7 1986.80 24 10.50 4037 1017 4.73 / 1097.83 3 3
7 13 1352.36 37 12.34 2836 1295 6.02 / 1099.13 3 4
8 13 211.68 37 13.69 1062 538 6.56 / 1099.67 3 10
9 8 -0.12 160 13.89 635 1411 7.97 / 1101.08 3 18
Average= 5.80 (KJ/cycle)

Cycle 188 GMT 4/11/2021 17:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 31 13.94 756 327 0.33 / 1085.61 3 5
2 12 1114.08 10 9.50 2598 247 0.57 / 1085.86 3 3
3 12 2001.12 60 7.33 3585 1577 2.15 / 1087.44 3 3
4 12 1992.76 58 7.43 3724 1605 3.76 / 1089.04 3 3
5 7 1985.76 24 10.58 3973 1009 4.76 / 1090.05 3 3
6 13 1235.72 37 12.47 2701 1246 6.01 / 1091.30 3 4
7 13 76.72 37 13.89 869 447 6.46 / 1091.74 3 6
8 8 0.04 160 13.97 609 1361 7.82 / 1093.11 3 13
Average= 5.78 (KJ/cycle)

Cycle 187 GMT 25/10/2021 17:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 30 13.93 760 318 0.32 / 1078.07 3 3
2 3 1028.80 1 12.05 2837 34 0.35 / 1078.10 3 3
3 3 1023.36 1 11.66 2668 31 0.38 / 1078.13 3 3
4 12 1136.72 10 9.48 2519 239 0.62 / 1078.37 3 3
5 12 2000.32 60 7.27 3597 1569 2.19 / 1079.94 3 3
6 12 1992.32 58 7.82 3643 1652 3.84 / 1081.59 3 3
7 7 1985.76 24 10.12 4789 1163 5.01 / 1082.75 3 3
8 13 1087.20 37 12.67 2430 1139 6.15 / 1083.89 3 6
9 8 0.12 160 13.95 625 1395 7.54 / 1085.29 3 15
Average= 5.77 (KJ/cycle)

Cycle 186 GMT 15/10/2021 17:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 30 13.95 747 313 0.31 / 1070.65 3 3
2 12 1118.04 10 9.80 2557 251 0.56 / 1070.90 3 3
3 12 2004.32 60 7.67 3616 1664 2.23 / 1072.57 3 3
4 12 1996.92 58 7.81 3632 1645 3.87 / 1074.21 3 3
5 7 1990.36 24 10.63 3968 1012 4.88 / 1075.23 3 3
6 13 1062.80 37 12.75 2349 1108 5.99 / 1076.33 3 6
7 8 0.08 160 13.95 633 1413 7.41 / 1077.75 3 13
Average= 5.76 (KJ/cycle)

Cycle 185 GMT 5/10/2021 17:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 30 13.91 791 330 0.33 / 1062.69 3 4
2 12 1140.28 10 9.12 2627 240 0.57 / 1062.93 3 3
3 12 2002.36 60 7.51 3628 1635 2.20 / 1064.57 3 3
4 12 1995.96 58 7.88 3726 1703 3.91 / 1066.27 3 3
5 7 1989.52 24 10.67 4069 1042 4.95 / 1067.31 3 3
6 13 1202.52 37 12.58 2625 1222 6.17 / 1068.53 3 5
7 13 26.00 37 13.98 787 407 6.58 / 1068.94 3 8
8 8 0.20 160 13.96 627 1400 7.98 / 1070.34 3 11
Average= 5.75 (KJ/cycle)

Cycle 184 GMT 25/ 9/2021 18: 9: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 30 13.91 763 318 0.32 / 1055.17 3 4
2 12 1107.52 10 9.60 2504 240 0.56 / 1055.41 3 3
3 12 2000.48 60 7.69 3560 1643 2.20 / 1057.05 3 3
4 12 1992.68 58 7.93 3670 1688 3.89 / 1058.74 3 3
5 7 1985.68 24 10.68 3998 1025 4.91 / 1059.77 3 3
6 13 1046.68 37 12.78 2368 1120 6.03 / 1060.88 3 7
7 8 0.08 160 13.87 666 1478 7.51 / 1062.36 3 11
Average= 5.74 (KJ/cycle)

Cycle 183 GMT 15/ 9/2021 18:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 30 13.90 762 318 0.32 / 1047.59 3 5
2 12 1120.12 10 9.87 2542 251 0.57 / 1047.84 3 3
3 12 2002.76 60 7.78 3609 1685 2.25 / 1049.52 3 3
4 12 1994.24 58 7.90 3678 1685 3.94 / 1051.21 3 3
5 7 1987.24 24 10.67 4115 1054 4.99 / 1052.26 3 3
6 13 1055.52 37 12.79 2391 1131 6.12 / 1053.40 3 7
7 8 -0.20 160 13.89 655 1456 7.58 / 1054.85 3 17
Average= 5.73 (KJ/cycle)

Cycle 182 GMT 5/ 9/2021 18:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 30 13.92 787 329 0.33 / 1040.48 3 5
2 12 1129.12 9 8.91 2629 211 0.54 / 1040.69 3 3
3 12 2001.96 58 7.49 3610 1568 2.11 / 1042.26 3 3
4 7 1998.28 24 10.57 3965 1006 3.11 / 1043.27 3 3
5 13 1731.48 37 12.11 3275 1467 4.58 / 1044.73 3 3
6 13 993.88 37 12.90 2248 1073 5.65 / 1045.81 3 7
7 8 0.16 160 13.87 660 1465 7.12 / 1047.27 3 11
Average= 5.72 (KJ/cycle)

Cycle 181 GMT 26/ 8/2021 18:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 30 13.97 744 312 0.31 / 1033.30 3 3
2 12 1114.36 9 8.93 2629 211 0.52 / 1033.51 3 3
3 12 2002.56 58 7.32 3701 1571 2.09 / 1035.08 3 3
4 7 1999.08 24 10.64 3953 1009 3.10 / 1036.09 3 3
5 13 1863.32 37 11.91 3500 1542 4.65 / 1037.63 3 3
6 13 967.56 37 12.93 2214 1059 5.71 / 1038.69 3 7
7 8 -0.16 160 13.90 658 1463 7.17 / 1040.15 3 8
Average= 5.72 (KJ/cycle)

Cycle 180 GMT 16/ 8/2021 19: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 30 13.95 748 313 0.31 / 1026.24 3 3
2 12 1131.84 9 10.01 2540 229 0.54 / 1026.47 3 3
3 12 2001.52 58 7.77 3645 1643 2.18 / 1028.11 3 3
4 7 1997.68 24 10.69 3914 1004 3.19 / 1029.12 3 3
5 13 1739.92 37 12.05 3368 1502 4.69 / 1030.62 3 3
6 13 841.60 37 13.04 2053 991 5.68 / 1031.61 3 6
7 8 -0.04 160 13.97 616 1377 7.06 / 1032.98 3 11
Average= 5.71 (KJ/cycle)

Cycle 179 GMT 6/ 8/2021 19:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 30 13.98 769 323 0.32 / 1019.23 3 3
2 12 1115.72 9 10.12 2658 242 0.56 / 1019.48 3 3
3 12 2001.44 54 8.11 3665 1605 2.17 / 1021.08 3 3
4 7 1997.44 24 10.60 3968 1009 3.18 / 1022.09 3 3
5 13 1724.08 37 12.06 3355 1497 4.68 / 1023.59 3 3
6 13 821.44 37 13.08 1952 945 5.62 / 1024.53 3 7
7 8 0.44 160 13.94 625 1394 7.01 / 1025.93 3 16
Average= 5.70 (KJ/cycle)

Cycle 178 GMT 27/ 7/2021 19:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 30 14.00 750 315 0.31 / 1012.14 3 3
2 12 1134.48 9 10.05 2624 237 0.55 / 1012.38 3 3
3 12 2000.48 54 8.39 3663 1660 2.21 / 1014.04 3 3
4 7 1996.04 24 10.66 3950 1011 3.22 / 1015.05 3 3
5 13 1720.56 37 12.09 3313 1482 4.70 / 1016.53 3 3
6 13 796.84 37 13.05 1979 956 5.66 / 1017.49 3 8
7 8 0.00 160 13.92 640 1425 7.09 / 1018.91 3 12
Average= 5.69 (KJ/cycle)

Cycle 177 GMT 17/ 7/2021 19: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 30 14.00 740 311 0.31 / 1005.25 3 3
2 12 1128.44 9 11.24 2681 271 0.58 / 1005.52 3 3
3 12 2003.00 54 8.50 3663 1681 2.26 / 1007.20 3 3
4 7 1998.76 24 10.70 3932 1010 3.27 / 1008.21 3 3
5 13 1584.68 37 12.28 3089 1404 4.68 / 1009.62 3 4
6 13 694.92 37 13.22 1733 848 5.52 / 1010.46 3 7
7 8 0.08 160 14.00 608 1362 6.89 / 1011.83 3 12
Average= 5.68 (KJ/cycle)

Cycle 176 GMT 7/ 7/2021 19: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 30 13.76 950 392 0.39 / 997.86 3 3
2 12 1124.08 9 10.50 2659 251 0.64 / 998.11 3 3
3 12 2000.52 54 8.57 3663 1695 2.34 / 999.81 3 3
4 7 1996.32 24 10.71 3850 990 3.33 / 1000.80 3 3
5 13 1721.32 37 12.09 3264 1460 4.79 / 1002.26 3 3
6 13 768.76 37 13.14 1855 902 5.69 / 1003.16 3 8
7 13 24.12 37 14.01 732 379 6.07 / 1003.54 3 9
8 8 0.08 160 13.93 628 1400 7.47 / 1004.94 3 15
Average= 5.68 (KJ/cycle)

Cycle 175 GMT 27/ 6/2021 18:56: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 31 13.94 751 325 0.32 / 990.63 3 5
2 3 927.76 -1 15.31 0 0 0.00 / 990.63 3 5
3 12 1098.24 9 10.09 2548 231 0.56 / 990.87 3 3
4 12 2001.28 54 8.39 3594 1628 2.18 / 992.49 3 3
5 7 1997.24 24 10.71 3890 1000 3.18 / 993.49 3 3
6 13 1596.40 37 12.25 3086 1399 4.58 / 994.89 3 3
7 13 699.72 37 13.19 1772 865 5.45 / 995.76 3 9
8 8 -0.40 160 13.89 647 1438 6.89 / 997.20 3 16
9 14 -0.40 30 14.07 653 276 7.16 / 997.47 3 16
Average= 5.67 (KJ/cycle)

Cycle 174 GMT 17/ 6/2021 18:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 31 14.06 723 315 0.32 / 983.79 3 3
2 12 1093.60 9 10.40 2667 250 0.56 / 984.04 3 3
3 12 2002.68 54 8.19 3624 1603 2.17 / 985.64 3 3
4 7 1999.04 24 10.72 3870 996 3.16 / 986.64 3 3
5 13 1595.92 37 12.26 3089 1401 4.56 / 988.04 3 3
6 13 713.16 37 13.21 1758 859 5.42 / 988.90 3 8
7 8 0.04 160 13.87 637 1414 6.84 / 990.31 3 16
Average= 5.66 (KJ/cycle)

Cycle 173 GMT 7/ 6/2021 18:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 30 14.07 733 309 0.31 / 977.00 3 3
2 3 1029.88 1 12.51 2835 35 0.34 / 977.04 3 3
3 3 1021.36 1 11.96 2716 32 0.38 / 977.07 3 3
4 12 1160.64 9 10.25 2590 239 0.62 / 977.31 3 3
5 12 2000.40 54 8.49 3619 1659 2.28 / 978.97 3 3
6 7 1995.92 24 10.78 3871 1002 3.28 / 979.97 3 3
7 13 1595.28 37 12.26 3085 1399 4.68 / 981.37 3 4
8 13 579.08 37 13.37 1568 776 5.45 / 982.14 3 7
9 8 0.28 160 14.04 592 1330 6.78 / 983.47 3 7
Average= 5.65 (KJ/cycle)

Cycle 172 GMT 28/ 5/2021 18:34: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 30 13.96 775 325 0.32 / 970.19 3 3
2 12 1146.00 9 10.82 2714 264 0.59 / 970.46 3 3
3 12 2003.28 54 8.93 3662 1766 2.35 / 972.22 3 3
4 7 1998.92 24 10.71 3920 1008 3.36 / 973.23 3 3
5 13 1443.08 37 12.38 2906 1331 4.69 / 974.56 3 4
6 13 571.44 37 13.35 1562 772 5.47 / 975.33 3 8
7 8 -0.12 160 14.03 604 1356 6.82 / 976.69 3 9
Average= 5.65 (KJ/cycle)

Cycle 171 GMT 18/ 5/2021 18: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 30 14.00 717 301 0.30 / 963.48 3 3
2 12 1124.20 9 10.89 2592 254 0.56 / 963.73 3 3
3 12 1999.60 54 8.73 3644 1718 2.27 / 965.45 3 3
4 7 1995.08 24 10.75 3889 1003 3.28 / 966.46 3 3
5 13 1448.36 37 12.43 2854 1313 4.59 / 967.77 3 5
6 13 559.28 37 13.37 1517 750 5.34 / 968.52 3 9
7 8 -0.12 160 13.96 605 1351 6.69 / 969.87 3 11
Average= 5.64 (KJ/cycle)

Cycle 170 GMT 8/ 5/2021 17:37:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 30 14.02 715 301 0.30 / 956.50 3 3
2 12 1112.28 9 10.59 2580 246 0.55 / 956.75 3 3
3 12 1999.72 54 8.74 3601 1700 2.25 / 958.45 3 3
4 7 1994.96 24 10.73 3886 1001 3.25 / 959.45 3 3
5 13 1580.72 37 12.26 3091 1402 4.65 / 960.85 3 4
6 13 812.76 37 13.11 1879 911 5.56 / 961.76 3 8
7 8 0.16 160 13.90 637 1417 6.98 / 963.18 3 11
Average= 5.63 (KJ/cycle)

Cycle 169 GMT 28/ 4/2021 17:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 29 14.01 728 296 0.30 / 949.61 3 3
2 12 1130.48 9 10.65 2643 253 0.55 / 949.86 3 3
3 12 2003.32 54 8.66 3607 1687 2.24 / 951.55 3 3
4 7 1999.04 24 10.80 3898 1010 3.25 / 952.56 3 3
5 13 1592.16 37 12.25 3112 1411 4.66 / 953.97 3 3
6 13 680.96 37 13.23 1734 849 5.51 / 954.82 3 9
7 8 -0.04 160 13.94 620 1383 6.89 / 956.20 3 9
Average= 5.62 (KJ/cycle)

Cycle 168 GMT 18/ 4/2021 16:59: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 31 13.99 713 309 0.31 / 942.73 3 3
2 3 951.16 -1 15.31 0 0 0.00 / 942.73 3 3
3 12 1127.64 9 10.50 2528 239 0.55 / 942.97 3 3
4 12 1998.32 54 8.83 3605 1719 2.27 / 944.69 3 3
5 7 1993.56 24 10.85 3830 997 3.26 / 945.69 3 3
6 13 1572.20 37 12.28 3052 1387 4.65 / 947.08 3 3
7 13 660.96 37 13.25 1709 838 5.49 / 947.91 3 8
8 8 -0.20 160 13.92 628 1399 6.89 / 949.31 3 10
Average= 5.62 (KJ/cycle)

Cycle 167 GMT 8/ 4/2021 16:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 30 14.02 789 332 0.33 / 935.83 3 3
2 3 1027.04 1 12.61 2677 34 0.37 / 935.87 3 3
3 12 1130.48 9 10.41 2530 237 0.60 / 936.11 3 3
4 12 2002.16 54 8.73 3742 1764 2.37 / 937.87 3 3
5 7 1997.92 24 10.87 3847 1004 3.37 / 938.87 3 3
6 13 1584.08 37 12.31 3057 1392 4.76 / 940.27 3 4
7 13 671.80 37 13.27 1680 825 5.59 / 941.09 3 7
8 8 0.12 160 13.93 599 1335 6.92 / 942.43 3 12
Average= 5.61 (KJ/cycle)

Cycle 166 GMT 29/ 3/2021 16:35: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 30 14.08 706 298 0.30 / 929.09 3 3
2 3 971.08 -1 15.29 1 0 0.00 / 929.09 3 3
3 3 1019.60 1 12.00 3196 38 0.34 / 929.13 3 3
4 12 1153.80 9 10.74 2564 248 0.58 / 929.38 3 3
5 12 2000.52 50 8.95 3634 1626 2.21 / 931.00 3 3
6 7 1996.04 24 10.85 3838 999 3.21 / 932.00 3 3
7 13 1585.32 37 12.31 3033 1381 4.59 / 933.39 3 4
8 13 681.52 37 13.28 1655 813 5.40 / 934.20 3 8
9 8 0.00 160 14.01 582 1305 6.71 / 935.50 3 15
Average= 5.60 (KJ/cycle)

Cycle 165 GMT 19/ 3/2021 16:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 30 14.09 693 293 0.29 / 921.89 3 3
2 12 1131.24 9 8.83 3207 255 0.55 / 922.15 3 3
3 12 2002.08 50 9.09 3683 1674 2.22 / 923.82 3 3
4 7 1998.04 24 10.78 3909 1011 3.23 / 924.83 3 3
5 13 1724.40 37 12.11 3271 1466 4.70 / 926.30 3 3
6 13 664.52 37 13.22 1708 835 5.53 / 927.13 3 8
7 13 15.56 37 14.10 646 337 5.87 / 927.47 3 12
8 8 0.12 160 13.99 591 1323 7.19 / 928.79 3 13
Average= 5.60 (KJ/cycle)

Cycle 164 GMT 9/ 3/2021 16:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 30 14.04 735 310 0.31 / 915.36 3 3
2 12 1117.84 9 10.59 2662 254 0.56 / 915.61 3 3
3 12 1734.84 50 9.32 3365 1568 2.13 / 917.18 3 3
4 7 1731.64 24 10.92 3616 948 3.08 / 918.13 3 3
5 13 1458.04 37 12.34 2890 1320 4.40 / 919.45 3 4
6 13 536.80 37 13.36 1508 745 5.14 / 920.19 3 8
7 8 -0.24 160 13.92 631 1405 6.55 / 921.60 3 8
Average= 5.59 (KJ/cycle)

Cycle 163 GMT 27/ 2/2021 16: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 30 14.03 675 284 0.28 / 908.62 3 3
2 12 1118.40 9 10.51 2673 253 0.54 / 908.87 3 3
3 12 2002.12 47 8.89 3662 1530 2.07 / 910.40 3 3
4 7 1998.16 24 10.82 3934 1022 3.09 / 911.43 3 3
5 13 1586.60 37 12.26 3074 1394 4.48 / 912.82 3 3
6 13 827.44 37 13.08 1921 930 5.41 / 913.75 3 7
7 8 0.24 160 13.97 582 1301 6.71 / 915.05 3 11
Average= 5.58 (KJ/cycle)

Cycle 162 GMT 17/ 2/2021 16: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 30 14.03 711 299 0.30 / 901.99 3 3
2 12 1129.24 9 10.71 2625 253 0.55 / 902.24 3 3
3 12 1999.16 47 9.11 3600 1541 2.09 / 903.78 3 3
4 7 1994.84 24 10.94 3769 990 3.08 / 904.77 3 3
5 13 1717.68 37 12.15 3209 1443 4.53 / 906.22 3 4
6 13 661.52 37 13.29 1625 799 5.32 / 907.02 3 10
7 8 -0.20 160 13.92 593 1321 6.65 / 908.34 3 14
Average= 5.57 (KJ/cycle)

Cycle 161 GMT 7/ 2/2021 16: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 29 14.03 692 282 0.28 / 895.39 3 4
2 12 1130.28 10 11.42 2500 285 0.57 / 895.67 3 3
3 12 2001.12 40 9.11 3581 1305 1.87 / 896.98 3 3
4 7 1997.00 24 10.91 3815 999 2.87 / 897.97 3 3
5 13 1603.44 37 12.23 3094 1400 4.27 / 899.37 3 4
6 13 854.20 37 13.03 1962 946 5.22 / 900.32 3 8
7 8 0.00 160 13.88 617 1370 6.59 / 901.69 3 15
Average= 5.57 (KJ/cycle)

Cycle 160 GMT 28/ 1/2021 15:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 29 13.93 898 363 0.36 / 888.94 3 3
2 12 1127.12 10 11.47 2409 276 0.64 / 889.22 3 3
3 12 1976.48 40 9.16 3556 1303 1.94 / 890.52 3 3
4 7 1972.20 24 10.97 3757 989 2.93 / 891.51 3 3
5 13 1701.08 37 12.07 3221 1438 4.37 / 892.95 3 3
6 13 792.84 37 13.12 1842 894 5.26 / 893.84 3 10
7 8 -0.08 160 13.95 565 1261 6.52 / 895.10 3 14
Average= 5.56 (KJ/cycle)

Cycle 159 GMT 18/ 1/2021 14:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 29 14.06 676 276 0.28 / 882.42 3 3
2 12 1132.04 6 9.71 2546 148 0.42 / 882.56 3 3
3 12 2001.20 33 9.08 3566 1069 1.49 / 883.63 3 3
4 7 1999.56 24 10.96 3710 976 2.47 / 884.61 3 3
5 13 1871.40 33 12.03 3414 1355 3.82 / 885.96 3 3
6 13 1142.68 33 12.84 2367 1003 4.83 / 886.97 3 6
7 13 115.88 33 13.94 792 364 5.19 / 887.33 3 12
8 8 0.08 160 13.96 559 1249 6.44 / 888.58 3 13
Average= 5.55 (KJ/cycle)

Cycle 158 GMT 8/ 1/2021 15: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 29 14.03 721 293 0.29 / 875.89 3 4
2 12 1122.96 6 9.46 2519 143 0.44 / 876.04 3 3
3 12 2003.00 33 8.79 3628 1052 1.49 / 877.09 3 3
4 7 2001.64 24 10.96 3777 994 2.48 / 878.08 3 3
5 13 1877.92 33 12.02 3458 1372 3.85 / 879.45 3 3
6 13 1151.88 33 12.82 2410 1020 4.87 / 880.47 3 5
7 13 118.56 33 13.91 843 387 5.26 / 880.86 3 12
8 8 -0.16 160 13.94 574 1280 6.54 / 882.14 3 10
Average= 5.55 (KJ/cycle)

Cycle 157 GMT 29/12/2020 15:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 29 14.06 706 288 0.29 / 869.30 3 3
2 12 1116.56 6 9.70 2440 142 0.43 / 869.44 3 3
3 12 2005.20 33 8.94 3543 1045 1.48 / 870.49 3 3
4 7 2003.68 24 11.03 3705 981 2.46 / 871.47 3 3
5 13 1876.84 33 12.05 3415 1358 3.81 / 872.83 3 4
6 13 1150.44 33 12.83 2398 1015 4.83 / 873.84 3 6
7 13 236.28 33 13.79 982 447 5.28 / 874.29 3 12
8 8 -0.04 160 13.91 588 1309 6.58 / 875.60 3 14
Average= 5.54 (KJ/cycle)

Cycle 156 GMT 19/12/2020 15:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 29 14.02 753 306 0.31 / 862.73 3 4
2 12 1133.04 6 8.92 2433 130 0.44 / 862.86 3 3
3 12 2001.44 33 8.84 3577 1043 1.48 / 863.90 3 3
4 7 1999.76 24 11.04 3769 999 2.48 / 864.90 3 3
5 13 1869.64 33 12.05 3475 1382 3.86 / 866.28 3 3
6 13 1151.80 33 12.83 2408 1020 4.88 / 867.30 3 7
7 13 123.96 33 13.91 858 394 5.27 / 867.70 3 13
8 8 -0.16 160 13.92 592 1319 6.59 / 869.01 3 15
Average= 5.54 (KJ/cycle)

Cycle 155 GMT 9/12/2020 16:19:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 29 13.99 767 311 0.31 / 856.02 3 3
2 12 1132.36 6 9.07 2416 131 0.44 / 856.15 3 3
3 12 2006.72 33 8.67 3584 1025 1.47 / 857.18 3 3
4 7 2005.36 24 11.06 3720 987 2.46 / 858.17 3 3
5 13 1888.00 33 12.06 3429 1365 3.82 / 859.53 3 3
6 13 1171.24 33 12.82 2429 1028 4.85 / 860.56 3 5
7 13 260.32 33 13.73 1080 489 5.34 / 861.05 3 16
8 8 0.20 160 13.86 620 1375 6.71 / 862.42 3 16
Average= 5.53 (KJ/cycle)

Cycle 154 GMT 29/11/2020 16:33: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 29 14.00 746 303 0.30 / 849.26 3 4
2 12 1115.60 6 8.58 2584 133 0.44 / 849.39 3 3
3 12 2002.04 33 8.73 3647 1051 1.49 / 850.44 3 3
4 7 2000.64 24 11.00 3792 1001 2.49 / 851.44 3 3
5 13 1873.80 33 12.04 3443 1368 3.86 / 852.81 3 3
6 13 1278.80 33 12.72 2598 1091 4.95 / 853.90 3 4
7 13 211.16 33 13.80 992 452 5.40 / 854.35 3 16
8 8 -0.12 160 13.89 610 1356 6.75 / 855.71 3 23
Average= 5.52 (KJ/cycle)

Cycle 153 GMT 19/11/2020 17: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 29 13.97 762 309 0.31 / 842.51 3 3
2 12 1136.64 6 8.64 2493 129 0.44 / 842.64 3 3
3 12 2005.56 33 8.88 3632 1064 1.50 / 843.71 3 3
4 7 2003.88 24 11.02 3800 1005 2.51 / 844.71 3 3
5 13 1870.52 33 12.09 3468 1384 3.89 / 846.09 3 3
6 13 1146.56 33 12.81 2463 1041 4.93 / 847.14 3 5
7 13 124.56 33 13.88 926 424 5.36 / 847.56 3 7
8 8 0.28 160 13.87 629 1396 6.75 / 848.96 3 12
Average= 5.51 (KJ/cycle)

Cycle 152 GMT 9/11/2020 17:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 29 13.98 751 304 0.30 / 835.66 3 5
2 12 1134.44 6 8.65 2408 125 0.43 / 835.79 3 3
3 12 2008.92 33 8.52 3824 1075 1.50 / 836.86 3 3
4 7 2007.72 24 11.01 3872 1023 2.53 / 837.88 3 3
5 13 1884.88 33 12.07 3505 1396 3.92 / 839.28 3 3
6 13 1170.08 33 12.81 2458 1039 4.96 / 840.32 3 5
7 13 277.12 33 13.75 1089 494 5.46 / 840.81 3 13
8 8 -0.20 160 13.86 627 1390 6.85 / 842.20 3 14
Average= 5.50 (KJ/cycle)

Cycle 151 GMT 30/10/2020 17:58: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 29 14.01 703 286 0.29 / 828.93 3 4
2 12 1122.92 6 9.05 2435 132 0.42 / 829.07 3 3
3 12 2003.04 33 8.72 3614 1040 1.46 / 830.11 3 3
4 7 2001.56 24 11.05 3769 1000 2.46 / 831.11 3 3
5 13 1875.28 33 12.08 3430 1367 3.82 / 832.47 3 3
6 13 1276.56 33 12.72 2587 1086 4.91 / 833.56 3 4
7 13 204.72 33 13.84 973 444 5.35 / 834.00 3 9
8 8 0.16 160 13.88 609 1352 6.71 / 835.36 3 14
Average= 5.50 (KJ/cycle)

Cycle 150 GMT 20/10/2020 18:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 29 14.04 706 287 0.29 / 822.38 3 6
2 12 1116.92 6 8.78 2406 127 0.41 / 822.50 3 3
3 12 2004.28 33 8.76 3576 1034 1.45 / 823.54 3 3
4 7 2003.00 24 11.06 3796 1008 2.46 / 824.54 3 3
5 13 1886.04 33 12.06 3448 1372 3.83 / 825.92 3 3
6 13 1299.84 33 12.72 2580 1083 4.91 / 827.00 3 5
7 13 120.16 33 13.94 812 374 5.28 / 827.37 3 13
8 8 -0.04 160 13.93 573 1277 6.56 / 828.65 3 17
Average= 5.49 (KJ/cycle)

Cycle 149 GMT 10/10/2020 19: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 28 14.06 696 274 0.27 / 815.98 3 4
2 12 1133.96 6 8.76 2401 126 0.40 / 816.10 3 3
3 12 2004.60 33 9.13 3562 1073 1.47 / 817.18 3 3
4 7 2003.20 24 11.04 3746 993 2.47 / 818.17 3 3
5 13 1878.44 33 12.10 3424 1367 3.83 / 819.54 3 3
6 13 1141.60 33 12.88 2337 993 4.83 / 820.53 3 6
7 13 115.44 33 13.97 760 350 5.18 / 820.88 3 7
8 8 0.08 160 13.99 539 1206 6.38 / 822.09 3 15
Average= 5.48 (KJ/cycle)

Cycle 148 GMT 30/ 9/2020 19:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 29 14.00 724 294 0.29 / 809.46 3 5
2 3 956.40 -1 15.33 0 0 0.00 / 809.46 3 5
3 12 1137.12 6 8.80 2492 132 0.43 / 809.59 3 3
4 12 2003.32 33 9.09 3701 1110 1.54 / 810.70 3 3
5 7 2001.80 24 11.07 3806 1011 2.55 / 811.72 3 3
6 13 1875.44 33 12.06 3477 1384 3.93 / 813.10 3 3
7 13 1148.76 33 12.85 2363 1002 4.93 / 814.10 3 6
8 13 117.12 33 13.96 787 363 5.30 / 814.46 3 15
9 8 -0.16 160 13.95 556 1241 6.54 / 815.70 3 15
Average= 5.47 (KJ/cycle)

Cycle 147 GMT 20/ 9/2020 20: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 28 14.05 706 278 0.28 / 802.85 3 6
2 3 1027.64 1 12.84 2309 30 0.31 / 802.88 3 3
3 12 1129.76 6 9.60 2323 134 0.44 / 803.01 3 3
4 12 2005.92 33 9.34 3540 1091 1.53 / 804.10 3 3
5 7 2004.44 24 11.02 3811 1008 2.54 / 805.11 3 3
6 13 1877.00 33 12.08 3420 1363 3.90 / 806.48 3 3
7 13 1265.20 33 12.74 2530 1064 4.97 / 807.54 3 6
8 13 23.44 33 14.02 699 323 5.29 / 807.86 3 9
9 8 0.08 160 13.88 588 1306 6.60 / 809.17 3 19
Average= 5.47 (KJ/cycle)

Cycle 146 GMT 10/ 9/2020 20:34: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 29 14.05 703 286 0.29 / 796.39 3 6
2 3 967.04 -1 15.33 1 0 0.00 / 796.39 3 6
3 12 1138.20 6 9.88 2291 136 0.42 / 796.52 3 3
4 12 2006.24 33 9.56 3478 1097 1.52 / 797.62 3 3
5 7 2004.48 24 11.07 3716 987 2.51 / 798.61 3 3
6 13 1873.60 33 12.08 3416 1362 3.87 / 799.97 3 3
7 13 1139.12 33 12.89 2285 972 4.84 / 800.94 3 5
8 13 103.48 33 13.96 776 357 5.20 / 801.30 3 9
9 8 0.32 160 13.91 572 1273 6.47 / 802.57 3 16
Average= 5.46 (KJ/cycle)

Cycle 145 GMT 31/ 8/2020 21: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 29 14.02 698 284 0.28 / 789.89 3 6
2 12 1117.44 6 9.16 2442 134 0.42 / 790.03 3 3
3 12 2005.00 33 9.32 3628 1116 1.53 / 791.14 3 3
4 7 2003.48 24 11.06 3704 983 2.52 / 792.13 3 3
5 13 1874.36 33 12.07 3379 1346 3.86 / 793.47 3 3
6 13 1130.08 33 12.86 2309 980 4.84 / 794.45 3 6
7 13 102.84 33 13.94 791 364 5.21 / 794.82 3 12
8 8 -0.08 160 13.90 578 1285 6.49 / 796.10 3 13
Average= 5.45 (KJ/cycle)

Cycle 144 GMT 21/ 8/2020 21:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 29 13.99 731 297 0.30 / 783.56 3 3
2 12 1131.20 6 9.44 2438 138 0.43 / 783.70 3 3
3 12 2006.16 33 9.66 3509 1119 1.55 / 784.82 3 3
4 7 2004.16 24 11.09 3651 972 2.53 / 785.79 3 3
5 13 1742.88 33 12.25 3200 1294 3.82 / 787.08 3 4
6 13 1031.20 33 12.96 2135 913 4.73 / 788.00 3 6
7 13 57.20 33 14.00 711 328 5.06 / 788.33 3 10
8 8 0.16 160 13.89 577 1282 6.34 / 789.61 3 17
Average= 5.45 (KJ/cycle)

Cycle 143 GMT 11/ 8/2020 21:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 28 14.01 699 274 0.27 / 777.04 3 6
2 12 1135.60 6 9.70 2396 139 0.41 / 777.18 3 3
3 12 2006.44 33 9.74 3573 1148 1.56 / 778.33 3 3
4 7 2004.64 24 11.06 3761 998 2.56 / 779.33 3 3
5 13 1870.76 33 12.04 3429 1362 3.92 / 780.69 3 4
6 13 1125.00 33 12.84 2337 990 4.91 / 781.68 3 6
7 13 46.00 33 14.01 711 329 5.24 / 782.01 3 8
8 8 0.04 160 13.90 566 1259 6.50 / 783.27 3 15
Average= 5.44 (KJ/cycle)

Cycle 142 GMT 1/ 8/2020 22: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 29 13.98 723 293 0.29 / 770.95 3 4
2 12 1104.44 6 9.77 2354 138 0.43 / 771.09 3 3
3 12 2003.08 33 9.72 3521 1129 1.56 / 772.22 3 3
4 7 2001.08 24 11.07 3712 986 2.55 / 773.20 3 3
5 13 1865.12 33 12.05 3431 1364 3.91 / 774.57 3 3
6 13 984.56 33 12.98 2105 902 4.81 / 775.47 3 6
7 8 0.16 160 13.88 584 1297 6.11 / 776.77 3 14
Average= 5.43 (KJ/cycle)

Cycle 141 GMT 22/ 7/2020 22:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 28 13.96 771 301 0.30 / 764.55 3 6
2 12 1128.72 6 10.01 2388 143 0.44 / 764.69 3 3
3 12 2005.40 33 9.98 3454 1138 1.58 / 765.83 3 3
4 7 2003.36 24 11.10 3662 976 2.56 / 766.80 3 3
5 13 1867.24 33 12.08 3379 1347 3.90 / 768.15 3 3
6 13 982.60 33 12.98 2111 904 4.81 / 769.05 3 6
7 13 49.84 33 14.00 706 326 5.14 / 769.38 3 11
8 8 -0.20 160 13.88 574 1275 6.41 / 770.66 3 18
Average= 5.43 (KJ/cycle)

Cycle 140 GMT 12/ 7/2020 22:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 29 14.01 720 293 0.29 / 758.12 3 4
2 12 1112.52 6 10.38 2319 144 0.44 / 758.27 3 3
3 12 2003.40 33 9.97 3389 1115 1.55 / 759.38 3 3
4 7 2001.00 24 11.19 3600 967 2.52 / 760.35 3 3
5 13 1741.84 33 12.24 3177 1283 3.80 / 761.63 3 3
6 13 1141.24 33 12.85 2280 967 4.77 / 762.60 3 6
7 13 94.08 33 13.94 763 351 5.12 / 762.95 3 14
8 8 -0.24 160 13.86 585 1297 6.42 / 764.25 3 17
Average= 5.42 (KJ/cycle)

Cycle 139 GMT 2/ 7/2020 22:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 29 14.02 727 296 0.30 / 751.78 3 4
2 12 1101.32 6 10.86 2336 152 0.45 / 751.93 3 3
3 12 2002.04 33 10.00 3453 1139 1.59 / 753.07 3 3
4 7 2000.04 24 11.14 3608 965 2.55 / 754.03 3 3
5 13 1864.76 33 12.06 3371 1342 3.89 / 755.38 3 4
6 13 978.56 33 12.99 2075 889 4.78 / 756.27 3 7
7 13 21.76 33 14.02 676 313 5.10 / 756.58 3 9
8 8 0.36 160 13.88 563 1250 6.35 / 757.83 3 15
Average= 5.41 (KJ/cycle)

Cycle 138 GMT 22/ 6/2020 23:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 29 14.04 706 287 0.29 / 745.31 3 5
2 12 1133.24 6 10.37 2595 161 0.45 / 745.47 3 3
3 12 2005.16 33 10.19 3510 1180 1.63 / 746.65 3 3
4 7 2003.12 24 11.07 3661 973 2.60 / 747.63 3 3
5 13 1870.00 33 12.08 3349 1335 3.94 / 748.96 3 3
6 13 992.68 33 12.98 2093 897 4.83 / 749.86 3 6
7 13 92.44 33 13.96 755 348 5.18 / 750.21 3 15
8 8 0.12 160 13.87 575 1276 6.46 / 751.48 3 13
Average= 5.41 (KJ/cycle)

Cycle 137 GMT 12/ 6/2020 23:33:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 29 14.05 713 291 0.29 / 738.87 3 5
2 12 1112.92 6 10.76 2528 163 0.45 / 739.03 3 3
3 12 2002.08 33 10.10 3539 1180 1.63 / 740.21 3 3
4 7 2000.00 24 11.04 3703 981 2.61 / 741.20 3 3
5 13 1732.64 33 12.19 3234 1301 3.92 / 742.50 3 4
6 13 994.84 33 12.94 2124 907 4.82 / 743.40 3 6
7 13 49.32 33 13.98 741 342 5.16 / 743.74 3 9
8 8 -0.24 160 13.87 577 1280 6.44 / 745.03 3 12
Average= 5.40 (KJ/cycle)

Cycle 136 GMT 2/ 6/2020 23:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 30 13.99 728 306 0.31 / 732.41 3 3
2 3 958.12 -1 15.34 0 0 0.00 / 732.41 3 3
3 12 1139.44 6 11.45 2440 168 0.47 / 732.58 3 3
4 12 2002.28 33 10.23 3520 1188 1.66 / 733.77 3 3
5 7 2000.00 24 11.07 3693 981 2.64 / 734.75 3 3
6 13 1736.28 33 12.16 3237 1299 3.94 / 736.05 3 3
7 13 992.92 33 12.92 2163 922 4.86 / 736.97 3 6
8 13 45.36 33 13.99 713 329 5.19 / 737.30 3 8
9 8 0.12 160 13.86 577 1280 6.47 / 738.58 3 15
Average= 5.39 (KJ/cycle)

Cycle 135 GMT 24/ 5/2020 0: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 31 13.98 726 315 0.31 / 725.88 3 3
2 3 914.64 -2 15.34 0 0 0.00 / 725.88 3 3
3 12 1140.56 6 11.37 2516 172 0.49 / 726.05 3 3
4 12 2003.48 33 10.32 3512 1196 1.68 / 727.25 3 3
5 7 2001.28 24 11.09 3639 969 2.65 / 728.22 3 3
6 13 1865.80 33 12.00 3418 1354 4.00 / 729.57 3 3
7 13 974.72 33 12.95 2107 900 4.90 / 730.47 3 7
8 13 38.12 33 13.99 691 319 5.22 / 730.79 3 10
9 8 0.08 160 13.83 595 1317 6.54 / 732.11 3 13
Average= 5.38 (KJ/cycle)

Cycle 134 GMT 14/ 5/2020 0:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 29 14.00 729 296 0.30 / 719.69 3 3
2 3 1070.20 2 12.90 2231 58 0.35 / 719.75 3 3
3 3 1030.20 1 12.52 2341 29 0.38 / 719.78 3 3
4 12 1137.40 6 11.66 2484 174 0.56 / 719.95 3 3
5 12 2002.60 33 10.38 3581 1227 1.78 / 721.18 3 3
6 7 2000.24 24 11.05 3710 984 2.77 / 722.16 3 3
7 13 1607.92 33 12.33 3018 1228 4.00 / 723.39 3 4
8 13 890.08 33 13.02 2003 861 4.86 / 724.25 3 8
9 8 0.20 160 13.84 594 1315 6.17 / 725.57 3 12
Average= 5.37 (KJ/cycle)

Cycle 133 GMT 4/ 5/2020 0:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 29 13.96 740 300 0.30 / 713.19 3 4
2 12 1108.16 6 11.86 2438 173 0.47 / 713.36 3 3
3 12 2001.92 33 10.32 3594 1224 1.70 / 714.59 3 3
4 7 1999.48 24 10.96 3799 999 2.70 / 715.58 3 3
5 13 1727.20 33 12.16 3202 1285 3.98 / 716.87 3 3
6 13 981.40 33 12.90 2148 914 4.90 / 717.78 3 5
7 13 40.32 33 13.96 730 336 5.23 / 718.12 3 12
8 8 -0.08 160 13.85 576 1276 6.51 / 719.40 3 11
Average= 5.37 (KJ/cycle)

Cycle 132 GMT 24/ 4/2020 0:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 30 13.98 863 362 0.36 / 706.81 3 3
2 12 1103.44 6 12.05 2286 165 0.53 / 706.98 3 3
3 12 1999.80 33 10.56 3464 1207 1.73 / 708.18 3 3
4 7 1997.04 24 11.06 3601 956 2.69 / 709.14 3 3
5 13 1727.80 33 12.16 3154 1266 3.96 / 710.41 3 3
6 13 974.16 33 12.92 2084 889 4.84 / 711.29 3 6
7 13 39.84 33 13.96 711 328 5.17 / 711.62 3 11
8 8 -0.12 160 13.86 571 1266 6.44 / 712.89 3 14
Average= 5.36 (KJ/cycle)

Cycle 131 GMT 14/ 4/2020 1: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 29 14.01 712 289 0.29 / 700.41 3 4
2 12 1138.56 6 12.19 2350 172 0.46 / 700.58 3 3
3 12 2002.24 33 10.57 3582 1249 1.71 / 701.83 3 3
4 7 1999.64 24 11.02 3646 964 2.67 / 702.79 3 3
5 13 1727.56 33 12.17 3158 1268 3.94 / 704.06 3 4
6 13 977.16 33 12.95 2051 876 4.82 / 704.94 3 6
7 13 40.52 33 14.04 649 301 5.12 / 705.24 3 10
8 8 -0.04 160 13.90 544 1210 6.33 / 706.45 3 15
Average= 5.35 (KJ/cycle)

Cycle 130 GMT 4/ 4/2020 1:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 29 14.09 681 278 0.28 / 694.05 3 3
2 12 1110.44 6 11.92 2378 170 0.45 / 694.22 3 3
3 12 2001.48 33 10.57 3564 1243 1.69 / 695.47 3 3
4 7 1998.64 24 10.97 3670 966 2.66 / 696.43 3 3
5 13 1608.32 33 12.22 3088 1245 3.90 / 697.68 3 4
6 13 879.52 33 13.00 1989 853 4.76 / 698.53 3 7
7 13 48.64 33 13.96 720 332 5.09 / 698.86 3 10
8 8 0.08 160 13.87 566 1256 6.34 / 700.12 3 21
Average= 5.34 (KJ/cycle)

Cycle 129 GMT 25/ 3/2020 1: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 29 14.04 704 287 0.29 / 687.71 3 3
2 12 1129.36 6 12.02 2370 171 0.46 / 687.88 3 3
3 12 2001.04 33 10.64 3523 1237 1.69 / 689.12 3 3
4 7 1998.36 24 11.06 3612 959 2.65 / 690.08 3 3
5 13 1723.32 33 12.16 3183 1277 3.93 / 691.35 3 3
6 13 966.44 33 12.94 2065 882 4.81 / 692.24 3 6
7 13 34.84 33 14.01 675 312 5.12 / 692.55 3 8
8 8 -0.04 160 13.88 553 1228 6.35 / 693.78 3 14
Average= 5.34 (KJ/cycle)

Cycle 128 GMT 15/ 3/2020 1: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 29 14.06 672 274 0.27 / 681.50 3 3
2 12 1124.92 6 12.12 2292 167 0.44 / 681.67 3 3
3 12 2002.36 33 10.79 3503 1247 1.69 / 682.91 3 3
4 7 1999.80 24 11.11 3562 950 2.64 / 683.86 3 3
5 13 1606.04 33 12.27 2996 1213 3.85 / 685.08 3 3
6 13 869.36 33 13.03 1905 819 4.67 / 685.90 3 7
7 13 44.56 33 14.01 654 302 4.97 / 686.20 3 10
8 8 -0.16 160 13.87 552 1225 6.20 / 687.42 3 16
Average= 5.33 (KJ/cycle)

Cycle 127 GMT 5/ 3/2020 1: 9: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 29 14.07 670 273 0.27 / 675.39 3 3
2 12 1127.76 6 12.26 2195 161 0.43 / 675.55 3 3
3 12 2000.44 33 10.77 3482 1238 1.67 / 676.79 3 3
4 7 1997.84 24 11.12 3554 948 2.62 / 677.74 3 3
5 13 1592.36 33 12.27 2988 1210 3.83 / 678.95 3 4
6 13 864.72 33 13.02 1895 814 4.64 / 679.76 3 7
7 13 22.64 33 14.04 617 286 4.93 / 680.05 3 8
8 8 -0.08 160 13.91 529 1177 6.11 / 681.23 3 16
Average= 5.32 (KJ/cycle)

Cycle 126 GMT 24/ 2/2020 0:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 29 14.04 713 290 0.29 / 669.11 3 3
2 12 1134.40 6 12.21 2427 178 0.47 / 669.29 3 3
3 12 2001.32 33 10.84 3534 1264 1.73 / 670.56 3 3
4 7 1998.60 24 11.12 3587 957 2.69 / 671.51 3 3
5 13 1717.40 33 12.13 3182 1274 3.96 / 672.79 3 3
6 13 839.04 33 13.03 1912 822 4.79 / 673.61 3 9
7 13 39.04 33 14.02 635 294 5.08 / 673.90 3 8
8 8 -0.16 160 13.88 547 1215 6.29 / 675.12 3 12
Average= 5.32 (KJ/cycle)

Cycle 125 GMT 14/ 2/2020 1: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 29 14.09 666 272 0.27 / 662.91 3 3
2 12 1126.08 6 12.35 2332 173 0.44 / 663.09 3 3
3 12 2004.96 33 10.83 3496 1249 1.69 / 664.34 3 3
4 7 2002.28 24 11.06 3567 947 2.64 / 665.28 3 3
5 13 1599.12 33 12.25 2987 1207 3.85 / 666.49 3 4
6 13 870.40 33 13.03 1901 817 4.67 / 667.31 3 6
7 13 42.44 33 14.02 639 296 4.96 / 667.60 3 14
8 8 0.08 160 13.86 550 1220 6.18 / 668.82 3 17
Average= 5.31 (KJ/cycle)

Cycle 124 GMT 4/ 2/2020 0:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 28 14.02 689 270 0.27 / 656.61 3 3
2 12 1128.20 6 12.23 2302 169 0.44 / 656.78 3 3
3 12 2002.00 33 10.78 3553 1264 1.70 / 658.05 3 3
4 7 1999.28 24 11.01 3665 968 2.67 / 659.02 3 3
5 13 1732.84 33 12.08 3237 1290 3.96 / 660.31 3 3
6 13 975.60 33 12.91 2058 877 4.84 / 661.18 3 6
7 13 33.44 33 14.03 613 284 5.12 / 661.47 3 9
8 8 0.08 160 13.89 529 1176 6.30 / 662.64 3 12
Average= 5.30 (KJ/cycle)

Cycle 123 GMT 25/ 1/2020 0:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 29 13.95 770 312 0.31 / 650.38 3 3
2 12 1114.24 6 12.02 2323 168 0.48 / 650.54 3 3
3 12 2001.84 33 10.79 3519 1253 1.73 / 651.80 3 3
4 7 1999.24 24 11.05 3625 961 2.69 / 652.76 3 3
5 13 1725.28 33 12.10 3175 1268 3.96 / 654.03 3 3
6 13 846.08 33 13.04 1877 808 4.77 / 654.83 3 7
7 13 41.24 33 14.00 662 306 5.07 / 655.14 3 9
8 8 -0.04 160 13.87 543 1205 6.28 / 656.34 3 15
Average= 5.29 (KJ/cycle)

Cycle 122 GMT 14/ 1/2020 23:59: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 29 14.00 692 281 0.28 / 644.27 3 3
2 12 1110.60 6 12.16 2207 161 0.44 / 644.44 3 3
3 12 2001.76 33 10.83 3490 1247 1.69 / 645.68 3 3
4 7 1999.12 24 11.08 3537 941 2.63 / 646.62 3 3
5 13 1594.36 33 12.29 2932 1189 3.82 / 647.81 3 3
6 13 850.12 33 13.05 1851 797 4.62 / 648.61 3 7
7 13 20.20 33 14.03 600 278 4.89 / 648.89 3 11
8 8 0.12 160 13.87 530 1176 6.07 / 650.06 3 12
Average= 5.29 (KJ/cycle)

Cycle 121 GMT 4/ 1/2020 23:34: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 29 14.05 660 269 0.27 / 638.15 3 3
2 12 1122.32 6 12.12 2255 164 0.43 / 638.31 3 3
3 12 1999.96 33 10.88 3485 1251 1.68 / 639.57 3 3
4 7 1997.12 24 11.10 3588 956 2.64 / 640.52 3 3
5 13 1590.16 33 12.30 2902 1178 3.82 / 641.70 3 4
6 13 848.00 33 13.06 1840 793 4.61 / 642.49 3 7
7 13 19.72 33 14.00 625 289 4.90 / 642.78 3 10
8 8 -0.12 160 13.78 550 1213 6.11 / 643.99 3 15
Average= 5.28 (KJ/cycle)

Cycle 120 GMT 25/12/2019 23:21: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 29 14.07 681 278 0.28 / 632.32 3 3
2 12 1137.76 6 12.38 2248 167 0.44 / 632.48 3 3
3 12 1999.36 33 10.99 3466 1257 1.70 / 633.74 3 3
4 7 1996.44 24 11.11 3505 935 2.64 / 634.67 3 3
5 13 1710.64 33 12.18 3078 1237 3.87 / 635.91 3 3
6 13 824.96 33 13.08 1794 774 4.65 / 636.69 3 7
7 8 0.08 160 13.89 538 1196 5.84 / 637.88 3 12
Average= 5.27 (KJ/cycle)

Cycle 119 GMT 15/12/2019 23: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 29 14.02 676 275 0.27 / 626.41 3 3
2 12 1124.76 6 12.13 2219 161 0.44 / 626.57 3 3
3 12 1999.68 33 10.87 3491 1252 1.69 / 627.83 3 3
4 7 1996.92 24 11.09 3568 950 2.64 / 628.78 3 3
5 13 1719.56 33 12.15 3140 1259 3.90 / 630.04 3 3
6 13 830.92 33 13.05 1847 795 4.69 / 630.83 3 7
7 8 -0.16 160 13.89 543 1207 5.90 / 632.04 3 12
Average= 5.27 (KJ/cycle)

Cycle 118 GMT 5/12/2019 22:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 29 14.00 705 286 0.29 / 620.49 3 3
2 12 1120.28 6 12.10 2302 167 0.45 / 620.66 3 3
3 12 2002.32 33 10.88 3522 1265 1.72 / 621.92 3 3
4 7 1999.72 24 11.09 3571 950 2.67 / 622.87 3 3
5 13 1597.88 33 12.25 3004 1214 3.88 / 624.09 3 4
6 13 863.48 33 13.02 1892 813 4.70 / 624.90 3 6
7 8 -0.04 160 13.84 559 1238 5.93 / 626.14 3 15
Average= 5.26 (KJ/cycle)

Cycle 117 GMT 25/11/2019 22: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 28 14.00 709 278 0.28 / 614.61 3 4
2 12 1127.40 6 12.32 2251 166 0.44 / 614.78 3 3
3 12 2001.28 33 11.00 3484 1265 1.71 / 616.04 3 3
4 7 1998.52 24 11.13 3534 944 2.65 / 616.99 3 3
5 13 1589.28 33 12.27 2950 1194 3.85 / 618.18 3 3
6 13 843.40 33 13.02 1886 810 4.66 / 618.99 3 7
7 8 0.00 160 13.83 549 1215 5.87 / 620.21 3 20
Average= 5.26 (KJ/cycle)

Cycle 116 GMT 15/11/2019 21:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 28 14.01 689 270 0.27 / 608.43 3 3
2 12 1112.68 6 12.00 2210 159 0.43 / 608.59 3 3
3 12 2001.28 33 10.91 3477 1252 1.68 / 609.84 3 3
4 7 1998.56 24 11.07 3550 943 2.62 / 610.78 3 3
5 13 1591.36 33 12.23 2993 1208 3.83 / 611.99 3 4
6 13 857.48 33 13.00 1915 822 4.65 / 612.81 3 7
7 13 43.44 33 13.97 682 314 4.97 / 613.13 3 10
8 8 0.04 160 13.82 546 1207 6.18 / 614.33 3 15
Average= 5.25 (KJ/cycle)

Cycle 115 GMT 5/11/2019 20:50: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 28 14.04 695 273 0.27 / 602.38 3 4
2 12 1120.20 6 12.30 2133 157 0.43 / 602.53 3 3
3 12 2000.60 33 10.93 3445 1243 1.67 / 603.78 3 3
4 7 1997.80 24 11.05 3602 955 2.63 / 604.73 3 3
5 13 1583.00 33 12.27 2932 1187 3.82 / 605.92 3 4
6 13 843.44 33 13.06 1832 790 4.61 / 606.71 3 7
7 13 20.68 33 14.03 605 280 4.89 / 606.99 3 10
8 8 0.12 160 13.84 528 1169 6.05 / 608.16 3 17
Average= 5.24 (KJ/cycle)

Cycle 114 GMT 26/10/2019 20: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 29 14.03 686 279 0.28 / 596.56 3 4
2 12 1111.64 6 12.18 2193 160 0.44 / 596.72 3 3
3 12 2000.24 33 11.00 3414 1239 1.68 / 597.96 3 3
4 7 1997.28 24 11.15 3472 929 2.61 / 598.89 3 3
5 13 1579.44 33 12.29 2897 1175 3.78 / 600.07 3 4
6 13 847.20 33 13.06 1828 788 4.57 / 600.85 3 8
7 8 0.36 160 13.80 565 1248 5.82 / 602.10 3 14
Average= 5.24 (KJ/cycle)

Cycle 113 GMT 16/10/2019 19:30:58

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 28 14.02 693 272 0.27 / 590.45 3 6
2 12 1133.52 6 12.23 2226 163 0.44 / 590.61 3 3
3 12 2001.36 33 10.99 3463 1256 1.69 / 591.87 3 3
4 7 1998.44 24 11.11 3549 946 2.64 / 592.82 3 3
5 13 1722.00 33 12.15 3114 1249 3.89 / 594.07 3 3
6 13 815.56 33 13.06 1814 782 4.67 / 594.85 3 7
7 8 0.76 160 13.84 547 1211 5.88 / 596.06 3 13
8 14 0.76 30 13.92 541 226 6.11 / 596.28 3 16
Average= 5.23 (KJ/cycle)

Cycle 112 GMT 6/10/2019 18:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 29 14.03 683 278 0.28 / 584.54 3 4
2 12 1107.72 6 12.02 2271 164 0.44 / 584.71 3 3
3 12 2001.12 33 10.97 3439 1245 1.69 / 585.95 3 3
4 7 1998.40 24 11.13 3486 931 2.62 / 586.88 3 3
5 13 1720.32 33 12.17 3062 1230 3.85 / 588.11 3 3
6 13 945.36 33 12.94 1980 845 4.69 / 588.96 3 6
7 8 0.08 160 13.83 551 1219 5.91 / 590.18 3 15
Average= 5.22 (KJ/cycle)

Cycle 111 GMT 26/ 9/2019 18:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 29 14.03 677 275 0.28 / 578.77 3 5
2 12 1109.44 6 12.29 2141 158 0.43 / 578.93 3 3
3 12 2001.84 33 10.99 3440 1248 1.68 / 580.18 3 3
4 7 1999.12 24 11.08 3472 923 2.60 / 581.10 3 3
5 13 1595.76 33 12.29 2899 1176 3.78 / 582.28 3 4
6 13 848.88 33 13.04 1834 789 4.57 / 583.07 3 7
7 8 0.20 160 13.84 542 1200 5.77 / 584.27 3 15
Average= 5.22 (KJ/cycle)

Cycle 110 GMT 16/ 9/2019 17:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 29 13.99 690 280 0.28 / 572.91 3 5
2 12 1108.16 6 12.20 2245 164 0.44 / 573.07 3 3
3 12 2002.80 33 10.96 3477 1258 1.70 / 574.33 3 3
4 7 2000.00 24 11.11 3492 931 2.63 / 575.26 3 3
5 13 1727.36 33 12.10 3147 1257 3.89 / 576.52 3 4
6 13 829.60 33 13.05 1836 791 4.68 / 577.31 3 6
7 8 0.20 160 13.83 538 1190 5.87 / 578.50 3 14
Average= 5.21 (KJ/cycle)

Cycle 109 GMT 6/ 9/2019 17:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 28 13.97 754 295 0.29 / 567.02 3 6
2 3 1027.72 1 12.05 2420 29 0.32 / 567.05 3 3
3 12 1134.40 6 12.10 2304 167 0.49 / 567.21 3 3
4 12 2000.16 33 11.03 3459 1259 1.75 / 568.47 3 3
5 7 1997.44 24 11.09 3542 943 2.69 / 569.41 3 3
6 13 1592.20 33 12.27 2917 1181 3.87 / 570.60 3 4
7 13 851.24 33 13.03 1849 795 4.67 / 571.39 3 7
8 8 0.08 160 13.80 560 1236 5.91 / 572.63 3 20
Average= 5.21 (KJ/cycle)

Cycle 108 GMT 27/ 8/2019 16:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 28 14.02 678 266 0.27 / 561.26 3 6
2 12 1107.00 6 12.11 2191 159 0.43 / 561.42 3 3
3 12 2002.36 33 10.94 3507 1266 1.69 / 562.69 3 3
4 7 1999.64 24 11.03 3585 949 2.64 / 563.64 3 3
5 13 1594.16 33 12.29 2885 1170 3.81 / 564.81 3 3
6 13 725.64 33 13.17 1649 717 4.53 / 565.52 3 7
7 8 0.00 160 13.84 541 1198 5.73 / 566.72 3 12
Average= 5.20 (KJ/cycle)

Cycle 107 GMT 17/ 8/2019 15:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 29 14.01 672 273 0.27 / 555.57 3 3
2 3 959.16 -1 15.38 0 0 0.00 / 555.57 3 3
3 12 1131.80 6 12.13 2233 163 0.44 / 555.74 3 3
4 12 2002.04 33 11.05 3451 1258 1.69 / 556.99 3 3
5 7 1998.96 24 11.11 3510 936 2.63 / 557.93 3 3
6 13 1472.44 33 12.38 2770 1132 3.76 / 559.06 3 4
7 13 755.40 33 13.14 1711 742 4.50 / 559.80 3 7
8 8 0.48 160 13.83 539 1193 5.70 / 561.00 3 16
Average= 5.19 (KJ/cycle)

Cycle 106 GMT 7/ 8/2019 14:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 28 14.02 697 274 0.27 / 549.62 3 4
2 3 1028.24 1 12.08 2215 27 0.30 / 549.64 3 3
3 12 1133.64 6 12.11 2290 166 0.47 / 549.81 3 3
4 12 2000.00 33 11.03 3522 1282 1.75 / 551.09 3 3
5 7 1997.24 24 11.06 3671 974 2.72 / 552.07 3 3
6 13 1593.84 33 12.25 2964 1198 3.92 / 553.26 3 4
7 13 854.12 33 12.98 1926 825 4.75 / 554.09 3 7
8 8 1.52 160 13.83 547 1210 5.96 / 555.30 3 15
Average= 5.19 (KJ/cycle)

Cycle 105 GMT 28/ 7/2019 14:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 28 13.97 711 278 0.28 / 543.73 3 5
2 12 1109.00 6 12.21 2233 164 0.44 / 543.89 3 3
3 12 2000.52 33 11.06 3473 1268 1.71 / 545.16 3 3
4 7 1997.48 25 11.07 3559 985 2.69 / 546.14 3 3
5 13 1588.12 33 12.24 2966 1198 3.89 / 547.34 3 4
6 13 846.68 33 13.03 1850 795 4.69 / 548.14 3 7
7 8 0.16 160 13.82 545 1205 5.89 / 549.34 3 15
Average= 5.18 (KJ/cycle)

Cycle 104 GMT 18/ 7/2019 13:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 29 14.02 679 276 0.28 / 537.73 3 3
2 3 970.24 -1 15.39 0 0 0.00 / 537.73 3 3
3 3 1023.72 1 11.25 2339 26 0.30 / 537.75 3 3
4 12 1143.40 6 12.22 2225 163 0.47 / 537.92 3 3
5 12 1999.88 33 11.12 3430 1259 1.72 / 539.18 3 3
6 7 1996.92 24 11.14 3484 931 2.66 / 540.11 3 3
7 13 1580.60 33 12.30 2848 1156 3.81 / 541.26 3 3
8 13 715.52 33 13.20 1629 710 4.52 / 541.97 3 7
9 13 23.40 33 14.03 597 276 4.80 / 542.25 3 10
10 8 0.00 160 13.80 544 1201 6.00 / 543.45 3 17
Average= 5.18 (KJ/cycle)

Cycle 103 GMT 8/ 7/2019 13:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 29 14.06 692 282 0.28 / 531.61 3 4
2 12 1135.44 6 12.28 2205 162 0.44 / 531.78 3 3
3 12 2000.40 33 11.03 3470 1263 1.71 / 533.04 3 3
4 7 1997.48 24 11.09 3586 954 2.66 / 533.99 3 3
5 13 1717.64 33 12.14 3086 1236 3.90 / 535.23 3 3
6 13 814.88 33 13.09 1758 759 4.66 / 535.99 3 7
7 13 16.00 33 14.05 588 273 4.93 / 536.26 3 9
8 8 -0.16 160 13.78 539 1188 6.12 / 537.45 3 13
Average= 5.17 (KJ/cycle)

Cycle 102 GMT 28/ 6/2019 12:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 29 14.04 674 274 0.27 / 525.82 3 4
2 3 967.88 -1 15.39 0 0 0.00 / 525.82 3 4
3 12 1137.08 6 12.37 2252 167 0.44 / 525.98 3 3
4 12 1999.92 33 11.11 3454 1266 1.71 / 527.25 3 3
5 7 1997.12 24 11.14 3504 937 2.64 / 528.19 3 3
6 13 1593.48 33 12.26 2930 1185 3.83 / 529.37 3 4
7 13 836.28 33 13.06 1810 780 4.61 / 530.15 3 7
8 8 -0.04 160 13.86 532 1180 5.79 / 531.33 3 9
Average= 5.16 (KJ/cycle)

Cycle 101 GMT 18/ 6/2019 12:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 28 14.05 683 269 0.27 / 520.08 3 5
2 3 1029.80 1 12.04 2178 26 0.29 / 520.10 3 3
3 12 1128.12 6 12.00 2268 163 0.46 / 520.27 3 3
4 12 1999.80 33 11.05 3416 1246 1.70 / 521.51 3 3
5 7 1996.92 24 11.18 3465 930 2.63 / 522.44 3 3
6 13 1591.92 33 12.30 2897 1176 3.81 / 523.62 3 4
7 13 717.72 33 13.17 1664 723 4.53 / 524.34 3 7
8 8 0.40 160 13.82 544 1203 5.74 / 525.54 3 12
Average= 5.15 (KJ/cycle)

Cycle 100 GMT 8/ 6/2019 11:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 28 14.09 680 268 0.27 / 514.33 3 3
2 12 1112.68 6 12.30 2135 158 0.43 / 514.49 3 3
3 12 2001.80 33 11.13 3404 1250 1.68 / 515.74 3 3
4 7 1999.16 24 11.16 3468 929 2.60 / 516.67 3 3
5 13 1586.00 33 12.30 2874 1167 3.77 / 517.83 3 3
6 13 844.68 33 13.04 1843 793 4.56 / 518.63 3 7
7 8 -0.32 160 13.85 533 1181 5.75 / 519.81 3 13
Average= 5.15 (KJ/cycle)

Cycle 99 GMT 29/ 5/2019 10:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 29 14.05 686 280 0.28 / 508.67 3 3
2 12 1110.64 6 12.36 2157 160 0.44 / 508.83 3 3
3 12 1999.44 33 11.09 3454 1264 1.70 / 510.10 3 3
4 7 1996.72 24 11.14 3523 942 2.65 / 511.04 3 3
5 13 1464.92 33 12.44 2678 1099 3.74 / 512.14 3 4
6 13 751.84 33 13.15 1697 736 4.48 / 512.87 3 7
7 8 0.24 160 13.85 536 1188 5.67 / 514.06 3 14
Average= 5.14 (KJ/cycle)

Cycle 98 GMT 19/ 5/2019 9:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 29 14.05 669 273 0.27 / 503.02 3 4
2 3 971.20 -1 15.39 1 0 0.00 / 503.02 3 4
3 3 1022.52 1 10.31 2258 23 0.30 / 503.04 3 3
4 12 1139.20 6 12.19 2213 162 0.46 / 503.21 3 3
5 12 2001.08 33 11.20 3395 1255 1.71 / 504.46 3 3
6 7 1998.44 24 11.27 3428 927 2.64 / 505.39 3 3
7 13 1589.08 33 12.33 2853 1161 3.80 / 506.55 3 4
8 13 721.12 33 13.21 1608 701 4.50 / 507.25 3 8
9 8 -0.04 160 13.88 514 1141 5.64 / 508.39 3 12
Average= 5.14 (KJ/cycle)

Cycle 97 GMT 9/ 5/2019 8:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 28 14.09 663 262 0.26 / 497.26 3 3
2 3 1021.56 1 10.56 2228 24 0.29 / 497.28 3 3
3 12 1131.64 6 12.29 2249 166 0.45 / 497.45 3 3
4 12 2001.76 33 11.19 3442 1271 1.72 / 498.72 3 3
5 7 1998.92 24 11.21 3476 935 2.66 / 499.66 3 3
6 13 1585.80 33 12.31 2889 1174 3.83 / 500.83 3 3
7 13 836.60 33 13.08 1783 770 4.60 / 501.60 3 10
8 8 0.52 160 13.88 518 1150 5.75 / 502.75 3 10
Average= 5.13 (KJ/cycle)

Cycle 96 GMT 29/ 4/2019 8:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 28 14.07 667 263 0.26 / 491.52 3 4
2 12 1121.76 6 12.21 2231 163 0.43 / 491.69 3 3
3 12 2000.96 33 11.09 3451 1263 1.69 / 492.95 3 3
4 7 1998.16 24 11.22 3493 941 2.63 / 493.89 3 3
5 13 1589.76 33 12.29 2904 1178 3.81 / 495.07 3 3
6 13 842.44 33 13.06 1809 780 4.59 / 495.85 3 6
7 8 0.32 160 13.86 519 1151 5.74 / 497.00 3 12
Average= 5.12 (KJ/cycle)

Cycle 95 GMT 19/ 4/2019 7:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 28 14.11 657 260 0.26 / 485.49 3 3
2 12 1125.32 6 12.30 2198 162 0.42 / 485.66 3 3
3 12 2001.28 33 11.13 3454 1269 1.69 / 486.92 3 3
4 7 1998.24 24 11.18 3493 937 2.63 / 487.86 3 3
5 13 1590.44 33 12.30 2885 1171 3.80 / 489.03 3 4
6 13 715.44 33 13.21 1625 708 4.51 / 489.74 3 7
7 13 122.24 33 13.92 735 338 4.84 / 490.08 3 10
8 8 -0.12 160 13.85 533 1181 6.03 / 491.26 3 12
Average= 5.12 (KJ/cycle)

Cycle 94 GMT 9/ 4/2019 6: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 28 14.16 638 253 0.25 / 479.83 3 3
2 12 1136.00 6 12.22 2216 162 0.42 / 480.00 3 3
3 12 2001.76 33 11.16 3466 1276 1.69 / 481.27 3 3
4 7 1998.92 24 11.21 3499 941 2.63 / 482.21 3 3
5 13 1589.32 33 12.35 2876 1172 3.81 / 483.39 3 4
6 13 718.40 33 13.20 1633 711 4.52 / 484.10 3 7
7 8 0.12 160 13.90 511 1136 5.65 / 485.23 3 13
Average= 5.11 (KJ/cycle)

Cycle 93 GMT 30/ 3/2019 5:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 28 14.10 682 269 0.27 / 474.06 3 3
2 12 1119.76 6 12.39 2164 161 0.43 / 474.22 3 3
3 12 2002.00 33 11.18 3487 1286 1.72 / 475.51 3 3
4 7 1999.24 24 11.21 3558 957 2.67 / 476.46 3 3
5 13 1590.08 33 12.29 2933 1190 3.86 / 477.65 3 4
6 13 847.24 33 13.06 1815 782 4.65 / 478.44 3 7
7 8 0.16 160 13.89 515 1145 5.79 / 479.58 3 14
Average= 5.10 (KJ/cycle)

Cycle 92 GMT 20/ 3/2019 4:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 31 14.08 691 302 0.30 / 467.98 3 3
2 3 889.24 -2 15.41 0 0 0.00 / 467.98 3 3
3 12 1110.48 6 12.23 2200 161 0.46 / 468.14 3 3
4 12 2002.60 33 11.13 3463 1272 1.73 / 469.41 3 3
5 7 1999.88 24 11.26 3460 935 2.67 / 470.35 3 3
6 13 1731.16 33 12.18 3085 1240 3.91 / 471.59 3 4
7 13 827.16 33 13.10 1771 766 4.68 / 472.35 3 7
8 13 32.56 33 14.05 603 280 4.96 / 472.63 3 9
9 8 -0.08 160 13.83 524 1160 6.11 / 473.79 3 17
Average= 5.09 (KJ/cycle)

Cycle 91 GMT 10/ 3/2019 3:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 28 14.25 642 256 0.26 / 461.83 3 3
2 3 1071.48 2 13.00 2122 55 0.31 / 461.89 3 3
3 3 1035.56 1 12.97 2141 28 0.34 / 461.92 3 3
4 12 1126.48 6 12.15 2261 165 0.50 / 462.08 3 3
5 12 2001.28 33 11.21 3444 1274 1.78 / 463.35 3 3
6 7 1998.52 24 11.26 3507 948 2.73 / 464.30 3 3
7 13 1585.24 33 12.35 2902 1183 3.91 / 465.48 3 4
8 13 834.96 33 13.09 1786 771 4.68 / 466.26 3 7
9 13 34.08 33 14.06 600 278 4.96 / 466.53 3 9
10 8 0.24 160 13.86 515 1142 6.10 / 467.68 3 14
Average= 5.08 (KJ/cycle)

Cycle 90 GMT 28/ 2/2019 3:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 28 14.16 636 252 0.25 / 455.67 3 3
2 12 1116.88 6 12.34 2199 163 0.41 / 455.84 3 3
3 12 2000.04 33 11.21 3426 1267 1.68 / 457.10 3 3
4 7 1997.24 24 11.34 3423 932 2.61 / 458.04 3 3
5 13 1586.56 33 12.35 2875 1172 3.79 / 459.21 3 4
6 13 703.48 33 13.25 1600 700 4.49 / 459.91 3 7
7 13 70.88 33 14.01 651 301 4.79 / 460.21 3 11
8 13 30.84 33 14.06 571 265 5.05 / 460.47 3 12
9 8 -0.04 160 13.89 496 1102 6.15 / 461.58 3 13
Average= 5.07 (KJ/cycle)

Cycle 89 GMT 18/ 2/2019 3: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 28 14.17 652 259 0.26 / 449.91 3 3
2 12 1122.20 6 12.32 2246 166 0.42 / 450.07 3 3
3 12 1999.80 33 11.19 3476 1284 1.71 / 451.36 3 3
4 7 1996.96 24 11.31 3493 948 2.66 / 452.30 3 3
5 13 1592.44 33 12.35 2895 1180 3.84 / 453.48 3 4
6 13 838.16 33 13.08 1808 780 4.62 / 454.26 3 8
7 8 -0.04 160 13.90 521 1159 5.78 / 455.42 3 17
Average= 5.06 (KJ/cycle)

Cycle 88 GMT 8/ 2/2019 2:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 29 14.19 624 257 0.26 / 444.24 3 3
2 12 1113.48 6 12.37 2147 159 0.42 / 444.40 3 3
3 12 2004.56 33 11.22 3395 1257 1.67 / 445.66 3 3
4 7 2001.80 24 11.35 3428 934 2.61 / 446.59 3 3
5 13 1588.28 33 12.35 2873 1171 3.78 / 447.76 3 4
6 13 831.08 33 13.11 1760 761 4.54 / 448.52 3 7
7 8 -0.04 160 13.92 505 1125 5.66 / 449.65 3 12
Average= 5.05 (KJ/cycle)

Cycle 87 GMT 29/ 1/2019 1:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 29 14.19 647 266 0.27 / 438.66 3 3
2 3 966.44 -1 15.41 0 0 0.00 / 438.66 3 3
3 12 1126.44 6 12.45 2167 162 0.43 / 438.82 3 3
4 12 2000.92 33 11.30 3435 1281 1.71 / 440.10 3 3
5 7 1998.08 24 11.37 3455 943 2.65 / 441.05 3 3
6 13 1459.84 33 12.47 2725 1121 3.77 / 442.17 3 4
7 13 732.84 33 13.25 1614 706 4.48 / 442.87 3 7
8 8 -0.20 160 13.94 498 1111 5.59 / 443.98 3 12
Average= 5.05 (KJ/cycle)

Cycle 86 GMT 19/ 1/2019 1:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 28 14.19 654 260 0.26 / 432.61 3 3
2 3 1020.24 1 10.68 2231 24 0.28 / 432.63 3 3
3 12 1136.20 6 12.29 2275 168 0.45 / 432.80 3 3
4 12 2001.76 33 11.27 3431 1276 1.73 / 434.08 3 3
5 7 1998.92 24 11.38 3473 949 2.68 / 435.03 3 3
6 13 1721.20 33 12.31 3015 1225 3.90 / 436.25 3 4
7 13 812.72 33 13.16 1745 758 4.66 / 437.01 3 9
8 13 14.12 33 14.14 549 256 4.91 / 437.27 3 8
9 8 -0.04 160 13.85 509 1128 6.04 / 438.39 3 9
Average= 5.04 (KJ/cycle)

Cycle 85 GMT 9/ 1/2019 1:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 28 14.18 631 251 0.25 / 426.94 3 3
2 12 1133.16 6 12.30 2186 161 0.41 / 427.10 3 3
3 12 2000.20 33 11.34 3397 1271 1.68 / 428.37 3 3
4 7 1997.20 24 11.37 3440 939 2.62 / 429.31 3 3
5 13 1584.16 33 12.42 2838 1163 3.78 / 430.47 3 3
6 13 834.96 33 13.17 1764 767 4.55 / 431.24 3 7
7 8 0.08 160 13.95 497 1109 5.66 / 432.35 3 14
Average= 5.03 (KJ/cycle)

Cycle 84 GMT 30/12/2018 1: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 28 14.22 637 254 0.25 / 421.27 3 3
2 12 1129.00 6 12.29 2296 169 0.42 / 421.44 3 3
3 12 2001.84 33 11.34 3435 1285 1.71 / 422.73 3 3
4 7 1998.96 24 11.42 3426 939 2.65 / 423.67 3 3
5 13 1580.96 33 12.42 2877 1179 3.83 / 424.85 3 4
6 13 822.28 33 13.19 1737 756 4.58 / 425.60 3 7
7 8 -0.12 160 13.97 486 1086 5.67 / 426.69 3 9
Average= 5.02 (KJ/cycle)

Cycle 83 GMT 20/12/2018 1: 3:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 28 14.18 644 256 0.26 / 415.69 3 3
2 12 1131.12 6 12.40 2156 160 0.42 / 415.85 3 3
3 12 2000.96 33 11.32 3344 1249 1.67 / 417.10 3 3
4 7 1998.12 24 11.45 3373 927 2.59 / 418.03 3 3
5 13 1580.28 33 12.47 2793 1149 3.74 / 419.18 3 5
6 13 833.52 33 13.21 1713 747 4.49 / 419.92 3 8
7 8 0.24 160 13.96 491 1097 5.58 / 421.02 3 11
Average= 5.01 (KJ/cycle)

Cycle 82 GMT 10/12/2018 0:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 28 14.20 630 250 0.25 / 410.04 3 3
2 12 1112.80 6 12.38 2187 162 0.41 / 410.20 3 3
3 12 2000.84 33 11.28 3404 1267 1.68 / 411.46 3 3
4 7 1998.16 24 11.44 3452 948 2.63 / 412.41 3 3
5 13 1582.12 33 12.45 2834 1164 3.79 / 413.58 3 3
6 13 824.72 33 13.21 1730 754 4.55 / 414.33 3 7
7 8 -0.08 160 13.95 495 1105 5.65 / 415.44 3 13
Average= 5.01 (KJ/cycle)

Cycle 81 GMT 30/11/2018 0:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 28 14.26 635 254 0.25 / 404.53 3 3
2 12 1134.80 6 12.37 2237 166 0.42 / 404.69 3 3
3 12 1999.44 33 11.38 3390 1273 1.69 / 405.97 3 3
4 7 1996.44 24 11.52 3377 934 2.63 / 406.90 3 3
5 13 1569.80 33 12.49 2796 1152 3.78 / 408.05 3 5
6 13 673.88 33 13.37 1490 657 4.44 / 408.71 3 8
7 8 0.00 160 13.98 480 1074 5.51 / 409.78 3 14
Average= 5.00 (KJ/cycle)

Cycle 80 GMT 20/11/2018 0:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 28 14.23 622 248 0.25 / 399.01 3 3
2 12 1124.64 6 12.10 2323 169 0.42 / 399.17 3 3
3 12 2000.76 33 11.31 3406 1271 1.69 / 400.45 3 3
4 7 1997.72 24 11.49 3419 943 2.63 / 401.39 3 3
5 13 1452.04 33 12.59 2651 1101 3.73 / 402.49 3 4
6 13 726.12 33 13.32 1573 691 4.42 / 403.18 3 8
7 8 0.08 160 13.95 490 1094 5.52 / 404.27 3 13
Average= 4.99 (KJ/cycle)

Cycle 79 GMT 9/11/2018 23:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 28 14.19 641 255 0.25 / 393.37 3 3
2 12 1119.72 6 12.29 2256 166 0.42 / 393.54 3 3
3 12 2000.16 33 11.36 3421 1282 1.70 / 394.82 3 3
4 7 1997.44 24 11.50 3436 948 2.65 / 395.77 3 3
5 13 1586.68 33 12.46 2884 1186 3.84 / 396.95 3 4
6 13 705.20 33 13.31 1584 696 4.53 / 397.65 3 7
7 8 -0.08 160 13.95 497 1109 5.64 / 398.76 3 15
Average= 4.98 (KJ/cycle)

Cycle 78 GMT 30/10/2018 23:13: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 28 14.24 640 255 0.26 / 387.82 3 3
2 12 1119.16 5 12.22 2135 130 0.39 / 387.95 3 3
3 12 2001.76 33 11.33 3346 1251 1.64 / 389.20 3 3
4 7 1999.08 24 11.57 3409 947 2.58 / 390.15 3 3
5 13 1577.28 33 12.52 2826 1168 3.75 / 391.32 3 4
6 13 695.64 33 13.35 1559 687 4.44 / 392.00 3 7
7 8 0.08 160 13.96 498 1112 5.55 / 393.12 3 13
Average= 4.98 (KJ/cycle)

Cycle 77 GMT 20/10/2018 23:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 27 14.25 699 269 0.27 / 381.93 3 3
2 12 1137.76 5 12.14 2286 139 0.41 / 382.07 3 3
3 12 2000.68 33 11.30 3417 1274 1.68 / 383.34 3 3
4 7 1997.96 24 11.55 3409 945 2.63 / 384.28 3 3
5 13 1583.00 33 12.52 2831 1170 3.80 / 385.45 3 4
6 13 824.60 33 13.24 1729 755 4.55 / 386.21 3 9
7 13 31.04 33 14.17 556 260 4.81 / 386.47 3 9
8 8 -0.12 160 13.92 492 1096 5.91 / 387.57 3 15
Average= 4.97 (KJ/cycle)

Cycle 76 GMT 10/10/2018 23:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 27 14.28 644 248 0.25 / 376.39 3 3
2 12 1119.00 5 12.36 2215 137 0.39 / 376.53 3 3
3 12 2002.60 30 11.40 3382 1157 1.54 / 377.69 3 3
4 7 2000.00 24 11.66 3383 947 2.49 / 378.63 3 3
5 13 1596.60 33 12.56 2807 1163 3.65 / 379.80 3 4
6 13 849.36 33 13.22 1757 767 4.42 / 380.56 3 8
7 8 0.04 160 14.00 488 1093 5.51 / 381.66 3 15
Average= 4.96 (KJ/cycle)

Cycle 75 GMT 30/ 9/2018 23:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 27 14.30 618 239 0.24 / 370.49 3 4
2 12 1115.84 5 11.98 2302 138 0.38 / 370.62 3 3
3 12 2005.96 30 11.20 3416 1148 1.52 / 371.77 3 3
4 7 2003.52 24 11.68 3359 942 2.47 / 372.71 3 3
5 13 1728.68 33 12.45 3026 1243 3.71 / 373.96 3 4
6 13 821.28 33 13.26 1729 757 4.47 / 374.71 3 10
7 13 128.60 33 14.08 698 324 4.79 / 375.04 3 11
8 8 -0.04 160 13.99 495 1108 5.90 / 376.15 3 12
Average= 4.95 (KJ/cycle)

Cycle 74 GMT 20/ 9/2018 22:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 28 14.25 635 253 0.25 / 365.10 3 3
2 3 941.96 -1 15.43 0 0 0.00 / 365.10 3 3
3 12 1124.36 3 10.12 2161 66 0.32 / 365.16 3 3
4 12 2000.92 30 11.09 3372 1122 1.44 / 366.28 3 3
5 7 1998.88 24 11.69 3371 946 2.39 / 367.23 3 3
6 13 1586.72 33 12.61 2799 1165 3.55 / 368.40 3 4
7 13 863.28 33 13.27 1758 770 4.32 / 369.17 3 8
8 8 0.04 160 14.04 482 1083 5.40 / 370.25 3 12
Average= 4.94 (KJ/cycle)

Cycle 73 GMT 10/ 9/2018 22:52:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 28 14.26 645 258 0.26 / 359.44 3 3
2 12 1108.20 3 10.40 2169 68 0.33 / 359.51 3 3
3 12 2001.88 30 11.09 3364 1119 1.44 / 360.63 3 3
4 7 1999.80 24 11.68 3387 949 2.39 / 361.58 3 3
5 13 1612.04 33 12.59 2844 1182 3.58 / 362.76 3 4
6 13 765.48 33 13.35 1643 724 4.30 / 363.49 3 7
7 13 15.84 33 14.23 521 245 4.54 / 363.73 3 8
8 8 0.00 160 13.92 500 1114 5.66 / 364.84 3 11
Average= 4.93 (KJ/cycle)

Cycle 72 GMT 31/ 8/2018 22:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 27 14.24 659 253 0.25 / 353.86 3 3
2 3 1031.16 1 12.97 2135 28 0.28 / 353.89 3 3
3 12 1130.64 3 10.42 2113 66 0.35 / 353.96 3 3
4 12 2001.64 30 11.10 3357 1118 1.46 / 355.07 3 3
5 7 1999.60 24 11.70 3383 950 2.41 / 356.02 3 3
6 13 1728.48 33 12.52 2969 1227 3.64 / 357.25 3 4
7 13 954.24 33 13.19 1881 819 4.46 / 358.07 3 7
8 8 0.24 160 14.00 499 1118 5.58 / 359.19 3 11
Average= 4.92 (KJ/cycle)

Cycle 71 GMT 21/ 8/2018 23:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 27 14.28 622 240 0.24 / 348.35 3 3
2 12 1129.64 3 10.61 2236 71 0.31 / 348.42 3 3
3 12 2004.88 30 11.08 3431 1140 1.45 / 349.56 3 3
4 7 2002.52 24 11.64 3440 961 2.41 / 350.52 3 3
5 13 1731.44 33 12.49 2989 1232 3.64 / 351.76 3 3
6 13 834.96 33 13.30 1719 754 4.40 / 352.51 3 7
7 8 -0.12 160 14.00 490 1098 5.50 / 353.61 3 11
Average= 4.91 (KJ/cycle)

Cycle 70 GMT 11/ 8/2018 23:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 27 14.28 619 239 0.24 / 342.88 3 3
2 3 968.64 -1 15.42 0 0 0.00 / 342.88 3 3
3 3 1024.12 1 12.39 2190 27 0.27 / 342.91 3 3
4 12 1140.76 3 11.32 2244 76 0.34 / 342.98 3 3
5 12 2003.68 30 11.18 3402 1141 1.48 / 344.12 3 3
6 7 2001.52 24 11.78 3370 953 2.44 / 345.08 3 3
7 13 1594.60 33 12.64 2798 1167 3.60 / 346.24 3 4
8 13 860.68 33 13.29 1765 774 4.38 / 347.02 3 6
9 8 0.24 160 14.03 488 1095 5.47 / 348.11 3 12
Average= 4.90 (KJ/cycle)

Cycle 69 GMT 1/ 8/2018 23:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 28 14.30 627 251 0.25 / 337.16 3 3
2 3 955.96 -1 15.43 0 0 0.00 / 337.16 3 3
3 12 1124.84 3 11.88 2280 81 0.33 / 337.24 3 3
4 12 2006.96 30 11.31 3381 1147 1.48 / 338.38 3 3
5 7 2005.00 24 11.71 3355 943 2.42 / 339.33 3 3
6 13 1739.28 33 12.49 2997 1235 3.66 / 340.56 3 4
7 13 854.96 33 13.28 1741 763 4.42 / 341.33 3 7
8 13 41.64 33 14.19 556 260 4.68 / 341.59 3 8
9 8 -0.04 160 14.00 470 1053 5.73 / 342.64 3 13
Average= 4.89 (KJ/cycle)

Cycle 68 GMT 23/ 7/2018 0: 9: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 28 14.29 629 252 0.25 / 331.16 3 3
2 12 1129.04 3 11.90 2205 79 0.33 / 331.24 3 3
3 7 2004.64 54 11.14 3344 2012 2.34 / 333.25 3 3
4 13 1731.68 33 12.51 2982 1231 3.57 / 334.48 3 4
5 13 961.08 33 13.20 1882 820 4.39 / 335.30 3 7
6 13 80.12 33 14.16 615 287 4.68 / 335.59 3 10
7 13 18.72 33 14.19 519 243 4.92 / 335.83 3 10
8 8 0.12 160 13.98 479 1071 5.99 / 336.91 3 7
Average= 4.88 (KJ/cycle)

Cycle 67 GMT 13/ 7/2018 0:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 28 14.30 635 254 0.25 / 325.73 3 3
2 12 1131.56 3 12.12 2173 79 0.33 / 325.81 3 3
3 7 2002.28 54 11.19 3344 2021 2.35 / 327.83 3 3
4 13 1738.12 33 12.49 3010 1241 3.59 / 329.07 3 4
5 13 853.48 33 13.29 1760 772 4.37 / 329.84 3 7
6 8 0.08 160 14.03 477 1071 5.44 / 330.91 3 15
Average= 4.87 (KJ/cycle)

Cycle 66 GMT 3/ 7/2018 0:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 28 14.29 617 247 0.25 / 320.45 3 3
2 12 1119.88 3 12.20 2090 76 0.32 / 320.52 3 3
3 7 2004.32 55 11.18 3306 2033 2.36 / 322.56 3 3
4 13 1594.20 33 12.67 2773 1159 3.52 / 323.72 3 4
5 13 725.72 33 13.45 1547 687 4.20 / 324.40 3 6
6 8 -0.20 160 14.04 477 1072 5.27 / 325.47 3 13
Average= 4.86 (KJ/cycle)

Cycle 65 GMT 23/ 6/2018 0:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 28 14.33 634 254 0.25 / 315.10 3 3
2 12 1130.16 3 12.27 2124 78 0.33 / 315.18 3 3
3 7 2002.92 54 11.25 3325 2020 2.35 / 317.20 3 3
4 13 1592.88 33 12.68 2799 1171 3.52 / 318.37 3 4
5 13 848.28 33 13.35 1718 757 4.28 / 319.12 3 6
6 8 0.24 160 14.04 479 1076 5.36 / 320.20 3 12
Average= 4.85 (KJ/cycle)

Cycle 64 GMT 13/ 6/2018 0:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 27 14.38 604 235 0.23 / 309.55 3 3
2 7 2002.48 54 11.37 3291 2021 2.26 / 311.57 3 3
3 13 1725.88 33 12.64 2926 1220 3.48 / 312.79 3 4
4 13 843.56 33 13.39 1710 756 4.23 / 313.54 3 8
5 13 18.56 33 14.28 501 236 4.47 / 313.78 3 7
6 8 -0.16 160 13.98 476 1065 5.53 / 314.84 3 13
Average= 4.84 (KJ/cycle)

Cycle 63 GMT 3/ 6/2018 1:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 27 14.37 597 232 0.23 / 304.15 3 3
2 7 2001.88 54 11.45 3306 2044 2.28 / 306.20 3 3
3 13 1734.16 33 12.65 2970 1240 3.52 / 307.44 3 3
4 13 978.08 33 13.29 1906 836 4.35 / 308.27 3 6
5 8 0.16 160 14.07 462 1040 5.39 / 309.31 3 14
Average= 4.83 (KJ/cycle)

Cycle 62 GMT 24/ 5/2018 2: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 28 14.37 593 239 0.24 / 298.88 3 3
2 7 2007.92 51 11.57 3291 1942 2.18 / 300.82 3 3
3 13 1879.20 22 12.74 3162 886 3.07 / 301.71 3 3
4 13 1168.48 22 13.33 2163 634 3.70 / 302.34 3 5
5 13 473.04 22 13.89 1164 356 4.06 / 302.70 3 11
6 13 32.68 22 14.26 539 169 4.23 / 302.87 3 7
7 8 -0.08 160 14.04 468 1051 5.28 / 303.92 3 14
Average= 4.82 (KJ/cycle)

Cycle 61 GMT 14/ 5/2018 2:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 28 14.40 611 246 0.25 / 293.87 3 3
2 7 2008.28 51 11.69 3263 1945 2.19 / 295.81 3 3
3 13 1617.96 22 13.02 2765 792 2.98 / 296.60 3 4
4 13 1197.52 22 13.33 2175 638 3.62 / 297.24 3 6
5 13 479.08 22 13.90 1163 356 3.98 / 297.60 3 7
6 8 0.04 160 14.08 464 1045 5.02 / 298.64 3 11
Average= 4.82 (KJ/cycle)

Cycle 60 GMT 4/ 5/2018 2:25: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 28 14.40 583 235 0.24 / 288.82 3 3
2 7 2008.68 51 11.77 3257 1955 2.19 / 290.78 3 3
3 13 1741.92 22 12.95 2951 841 3.03 / 291.62 3 4
4 13 1173.00 22 13.38 2146 632 3.66 / 292.25 3 6
5 13 453.20 22 13.94 1117 343 4.01 / 292.59 3 7
6 8 -0.08 160 14.11 455 1027 5.03 / 293.62 3 11
Average= 4.81 (KJ/cycle)

Cycle 59 GMT 24/ 4/2018 2:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 28 14.42 581 235 0.23 / 283.77 3 3
2 7 2003.56 51 11.90 3266 1982 2.22 / 285.75 3 3
3 13 1738.32 22 12.98 2956 844 3.06 / 286.59 3 4
4 13 1161.16 22 13.38 2145 631 3.69 / 287.23 3 6
5 13 447.60 22 13.96 1113 342 4.03 / 287.57 3 9
6 8 -0.12 160 14.13 451 1020 5.05 / 288.59 3 11
Average= 4.81 (KJ/cycle)

Cycle 58 GMT 14/ 4/2018 3: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 28 14.44 590 239 0.24 / 278.64 3 3
2 7 2005.64 51 12.03 3243 1990 2.23 / 280.63 3 3
3 13 1737.52 22 13.04 2911 835 3.06 / 281.47 3 3
4 13 1025.84 22 13.49 1936 575 3.64 / 282.04 3 6
5 13 459.60 22 13.95 1120 344 3.98 / 282.39 3 8
6 13 31.96 22 14.34 495 156 4.14 / 282.54 3 8
7 8 -0.28 160 14.12 439 992 5.13 / 283.53 3 12
Average= 4.81 (KJ/cycle)

Cycle 57 GMT 4/ 4/2018 3:17: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 27 14.43 599 233 0.23 / 273.67 3 3
2 7 2008.28 51 12.14 3262 2020 2.25 / 275.69 3 3
3 13 1612.56 22 13.13 2766 799 3.05 / 276.49 3 4
4 13 1180.00 22 13.42 2147 634 3.69 / 277.12 3 5
5 13 314.44 22 14.09 899 279 3.96 / 277.40 3 11
6 8 -0.16 160 14.15 444 1005 4.97 / 278.40 3 13
Average= 4.80 (KJ/cycle)

Cycle 56 GMT 25/ 3/2018 3:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 28 14.46 589 238 0.24 / 268.75 3 3
2 7 2008.20 51 12.24 3241 2023 2.26 / 270.77 3 3
3 13 1603.20 22 13.15 2752 796 3.06 / 271.57 3 4
4 13 1050.32 22 13.51 1955 581 3.64 / 272.15 3 7
5 13 333.72 22 14.08 928 287 3.93 / 272.43 3 9
6 8 0.20 160 14.15 442 1001 4.93 / 273.43 3 15
Average= 4.80 (KJ/cycle)

Cycle 55 GMT 15/ 3/2018 3:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 27 14.42 591 230 0.23 / 263.48 3 3
2 7 2004.16 51 12.32 3229 2029 2.26 / 265.51 3 3
3 13 1600.40 22 13.18 2722 789 3.05 / 266.30 3 4
4 13 1037.52 22 13.54 1942 578 3.63 / 266.88 3 6
5 13 311.24 22 14.10 888 275 3.90 / 267.15 3 6
6 8 0.16 160 14.17 432 979 4.88 / 268.13 3 7
7 14 0.16 60 14.14 443 376 5.26 / 268.51 3 13
Average= 4.79 (KJ/cycle)

Cycle 54 GMT 5/ 3/2018 3:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 27 14.44 598 233 0.23 / 258.57 3 3
2 7 2002.84 51 12.33 3236 2035 2.27 / 260.60 3 3
3 13 1591.36 22 13.18 2723 790 3.06 / 261.39 3 4
4 13 1028.96 22 13.55 1940 578 3.64 / 261.97 3 8
5 13 322.44 22 14.09 919 285 3.92 / 262.26 3 8
6 8 0.16 160 14.17 438 993 4.91 / 263.25 3 12
Average= 4.79 (KJ/cycle)

Cycle 53 GMT 23/ 2/2018 4:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 28 14.42 588 237 0.24 / 253.64 3 3
2 3 966.84 -1 15.40 0 0 0.00 / 253.64 3 3
3 7 2005.60 51 12.33 3237 2036 2.27 / 255.68 3 3
4 13 1594.12 22 13.17 2708 785 3.06 / 256.46 3 5
5 13 1022.56 22 13.54 1923 573 3.63 / 257.04 3 6
6 13 309.20 22 14.10 902 280 3.91 / 257.32 3 14
7 8 -0.12 160 14.15 450 1019 4.93 / 258.34 3 10
Average= 4.78 (KJ/cycle)

Cycle 52 GMT 13/ 2/2018 4:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 28 14.43 603 244 0.24 / 248.69 3 3
2 7 2002.12 51 12.35 3218 2027 2.27 / 250.72 3 3
3 13 1590.80 22 13.20 2691 781 3.05 / 251.50 3 4
4 13 1024.92 22 13.55 1909 569 3.62 / 252.07 3 7
5 13 443.44 22 13.99 1077 331 3.95 / 252.40 3 9
6 8 0.04 160 14.16 445 1008 4.96 / 253.41 3 13
Average= 4.78 (KJ/cycle)

Cycle 51 GMT 3/ 2/2018 4:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 28 14.46 587 238 0.24 / 243.62 3 3
2 7 2002.40 51 12.36 3222 2031 2.27 / 245.65 3 3
3 13 1597.68 22 13.19 2707 786 3.05 / 246.43 3 5
4 13 1033.24 22 13.55 1939 578 3.63 / 247.01 3 6
5 13 314.44 22 14.11 896 278 3.91 / 247.29 3 9
6 13 14.08 22 14.37 465 147 4.06 / 247.44 3 8
7 8 -0.08 160 14.11 447 1009 5.07 / 248.45 3 14
Average= 4.78 (KJ/cycle)

Cycle 50 GMT 24/ 1/2018 5: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 27 14.44 603 235 0.24 / 238.44 3 3
2 7 2006.92 51 12.33 3234 2034 2.27 / 240.47 3 3
3 13 1602.80 28 13.09 2705 991 3.26 / 241.46 3 4
4 13 1013.88 28 13.48 1892 714 3.97 / 242.18 3 7
5 13 28.04 28 14.38 472 190 4.16 / 242.37 3 9
6 8 -0.24 160 14.14 448 1014 5.18 / 243.38 3 14
Average= 4.77 (KJ/cycle)

Cycle 49 GMT 14/ 1/2018 5:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 28 14.49 588 239 0.24 / 233.33 3 3
2 7 2007.32 51 12.29 3230 2025 2.26 / 235.36 3 3
3 13 1596.36 28 13.07 2692 985 3.25 / 236.34 3 4
4 13 876.68 28 13.57 1697 645 3.89 / 236.99 3 8
5 13 55.16 28 14.35 514 207 4.10 / 237.19 3 8
6 8 0.20 160 14.15 446 1010 5.11 / 238.20 3 12
Average= 4.76 (KJ/cycle)

Cycle 48 GMT 4/ 1/2018 5:39: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 27 14.47 602 235 0.24 / 228.23 3 3
2 7 2006.80 52 12.29 3219 2057 2.29 / 230.28 3 3
3 13 1586.84 28 13.08 2686 984 3.28 / 231.27 3 4
4 13 848.32 28 13.61 1654 630 3.91 / 231.90 3 7
5 13 24.96 28 14.40 469 189 4.10 / 232.09 3 10
6 8 0.08 160 14.16 444 1006 5.10 / 233.09 3 14
Average= 4.76 (KJ/cycle)

Cycle 47 GMT 25/12/2017 6: 6: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 27 14.46 600 234 0.23 / 223.09 3 3
2 3 1031.28 1 13.91 1944 27 0.26 / 223.12 3 3
3 7 2004.48 51 12.29 3210 2012 2.27 / 225.13 3 3
4 13 1602.88 28 13.08 2667 977 3.25 / 226.10 3 4
5 13 1015.04 28 13.48 1879 709 3.96 / 226.81 3 6
6 13 27.48 28 14.41 466 188 4.15 / 227.00 3 8
7 8 -0.08 160 14.18 436 989 5.14 / 227.99 3 11
Average= 4.75 (KJ/cycle)

Cycle 46 GMT 15/12/2017 6:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 27 14.44 583 227 0.23 / 217.97 3 3
2 3 973.32 -1 15.41 0 0 0.00 / 217.97 3 3
3 3 1020.08 1 13.42 1945 26 0.25 / 217.99 3 3
4 7 2008.36 51 12.27 3224 2017 2.27 / 220.01 3 3
5 13 1597.60 28 13.08 2675 980 3.25 / 220.99 3 4
6 13 875.80 28 13.59 1688 642 3.89 / 221.63 3 7
7 13 55.24 28 14.38 514 207 4.10 / 221.84 3 11
8 8 0.08 160 14.16 448 1015 5.11 / 222.85 3 11
Average= 4.74 (KJ/cycle)

Cycle 45 GMT 5/12/2017 6:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 26 14.47 599 225 0.23 / 212.90 3 3
2 3 1028.00 1 13.62 1952 27 0.25 / 212.93 3 3
3 7 2003.24 51 12.27 3207 2007 2.26 / 214.93 3 3
4 13 1593.48 28 13.08 2663 975 3.23 / 215.91 3 4
5 13 866.92 28 13.59 1674 637 3.87 / 216.55 3 7
6 13 51.12 28 14.39 503 203 4.07 / 216.75 3 7
7 8 0.04 160 14.19 437 992 5.07 / 217.74 3 16
Average= 4.73 (KJ/cycle)

Cycle 44 GMT 25/11/2017 7:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 27 14.49 579 227 0.23 / 207.20 3 3
2 3 963.76 -1 15.39 0 0 0.00 / 207.20 3 3
3 7 2008.20 110 11.99 3190 4207 4.43 / 211.41 3 3
4 13 185.16 28 14.24 695 277 4.71 / 211.68 3 8
5 8 -0.28 160 14.22 435 990 5.70 / 212.67 3 12
Average= 4.73 (KJ/cycle)

Cycle 43 GMT 15/11/2017 8:10: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 26 14.52 586 221 0.22 / 202.15 3 3
2 3 1025.36 1 14.00 1914 27 0.25 / 202.18 3 3
3 7 2005.28 51 12.28 3197 2002 2.25 / 204.18 3 3
4 13 1601.56 28 13.09 2685 984 3.23 / 205.16 3 4
5 13 877.64 28 13.62 1672 638 3.87 / 205.80 3 8
6 13 24.08 28 14.44 458 185 4.06 / 205.99 3 11
7 8 -0.04 160 14.20 435 988 5.05 / 206.97 3 12
Average= 4.70 (KJ/cycle)

Cycle 42 GMT 5/11/2017 8:28: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 27 14.49 589 230 0.23 / 197.31 3 3
2 7 2005.48 51 12.35 3205 2019 2.25 / 199.33 3 3
3 13 1587.08 28 13.14 2657 978 3.23 / 200.31 3 5
4 13 857.56 28 13.66 1659 635 3.86 / 200.94 3 8
5 8 0.32 160 14.24 432 984 4.85 / 201.93 3 14
Average= 4.70 (KJ/cycle)

Cycle 41 GMT 26/10/2017 8:46: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 27 14.51 595 233 0.23 / 192.49 3 3
2 7 2004.24 46 12.48 3217 1847 2.08 / 194.34 3 3
3 13 1739.88 22 13.18 2871 832 2.91 / 195.17 3 4
4 13 1043.08 22 13.62 1928 578 3.49 / 195.75 3 7
5 13 472.28 22 14.09 1104 342 3.83 / 196.09 3 9
6 8 0.12 160 14.26 434 990 4.82 / 197.08 3 13
Average= 4.69 (KJ/cycle)

Cycle 40 GMT 16/10/2017 8:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 27 14.51 598 234 0.23 / 187.61 3 3
2 7 2004.12 46 12.59 3208 1858 2.09 / 189.47 3 3
3 13 1744.84 22 13.22 2890 841 2.93 / 190.31 3 4
4 13 1171.08 22 13.58 2088 624 3.56 / 190.93 3 6
5 13 454.76 22 14.13 1091 339 3.90 / 191.27 3 7
6 8 0.04 160 14.27 434 991 4.89 / 192.26 3 15
Average= 4.69 (KJ/cycle)

Cycle 39 GMT 6/10/2017 9: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 26 14.55 593 224 0.22 / 182.70 3 4
2 3 1024.68 1 14.24 1944 28 0.25 / 182.72 3 3
3 7 2006.44 47 12.62 3210 1904 2.16 / 184.63 3 3
4 13 1737.36 22 13.26 2878 840 3.00 / 185.47 3 4
5 13 1159.48 22 13.62 2066 619 3.61 / 186.09 3 6
6 13 420.36 22 14.18 1027 320 3.94 / 186.41 3 9
7 8 0.16 160 14.29 423 967 4.90 / 187.37 3 12
Average= 4.68 (KJ/cycle)

Cycle 38 GMT 26/ 9/2017 9:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 26 14.58 570 216 0.22 / 177.96 3 4
2 7 2008.24 46 12.68 3216 1876 2.09 / 179.83 4 3
3 13 1614.20 22 13.37 2693 792 2.88 / 180.62 3 4
4 13 1065.64 22 13.70 1936 584 3.47 / 181.21 3 7
5 13 354.44 22 14.25 925 290 3.76 / 181.50 3 11
6 8 -0.24 160 14.30 426 975 4.73 / 182.47 3 17
Average= 4.68 (KJ/cycle)

Cycle 37 GMT 16/ 9/2017 9:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 26 14.57 580 220 0.22 / 173.15 3 3
2 3 1026.96 1 14.28 1933 28 0.25 / 173.18 3 3
3 7 2006.32 47 12.68 3214 1915 2.16 / 175.09 3 3
4 13 1738.08 22 13.31 2873 841 3.00 / 175.94 3 4
5 13 1025.36 22 13.73 1890 571 3.57 / 176.51 3 6
6 13 315.56 22 14.30 874 275 3.85 / 176.78 3 12
7 8 -0.04 160 14.32 418 958 4.81 / 177.74 3 14
Average= 4.68 (KJ/cycle)

Cycle 36 GMT 6/ 9/2017 9:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 26 14.56 570 216 0.22 / 168.33 3 3
2 3 970.56 -1 15.40 0 0 0.00 / 168.33 3 3
3 7 2008.28 46 12.76 3218 1889 2.10 / 170.22 3 3
4 13 1606.44 22 13.41 2685 792 2.90 / 171.01 3 5
5 13 1178.52 22 13.67 2089 628 3.52 / 171.64 3 5
6 13 449.84 22 14.20 1060 331 3.86 / 171.97 3 11
7 8 0.08 160 14.33 419 961 4.82 / 172.93 3 15
Average= 4.67 (KJ/cycle)

Cycle 35 GMT 27/ 8/2017 9:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 26 14.60 579 220 0.22 / 163.47 3 3
2 3 1023.24 1 14.30 1918 27 0.25 / 163.49 3 3
3 7 2006.44 46 12.79 3196 1880 2.13 / 165.37 3 3
4 13 1731.40 22 13.32 2873 842 2.97 / 166.22 3 4
5 13 1155.48 22 13.70 2051 618 3.59 / 166.83 3 8
6 13 427.80 22 14.23 1029 322 3.91 / 167.16 3 9
7 8 0.28 160 14.34 418 959 4.87 / 168.11 3 14
Average= 4.67 (KJ/cycle)

Cycle 34 GMT 17/ 8/2017 10: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 26 14.59 562 213 0.21 / 158.52 3 4
2 7 2006.52 46 12.81 3198 1884 2.10 / 160.40 3 3
3 13 1736.48 32 13.23 2835 1200 3.30 / 161.60 3 4
4 13 832.56 32 13.81 1595 705 4.00 / 162.31 3 8
5 8 0.20 160 14.33 410 940 4.94 / 163.25 3 11
Average= 4.66 (KJ/cycle)

Cycle 33 GMT 7/ 8/2017 10:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 26 14.56 568 215 0.22 / 153.52 3 3
2 7 2006.28 47 12.81 3208 1931 2.15 / 155.45 3 3
3 13 1731.08 32 13.24 2813 1192 3.34 / 156.65 3 4
4 13 826.48 32 13.82 1592 704 4.04 / 157.35 3 7
5 8 0.36 160 14.33 416 954 5.00 / 158.30 3 18
Average= 4.66 (KJ/cycle)

Cycle 32 GMT 28/ 7/2017 10:56: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 26 14.59 555 211 0.21 / 148.62 3 4
2 7 2004.08 46 12.85 3195 1889 2.10 / 150.51 3 4
3 13 1601.16 32 13.33 2649 1130 3.23 / 151.64 3 4
4 13 857.68 32 13.81 1626 719 3.95 / 152.36 3 7
5 8 -0.40 160 14.35 412 946 4.89 / 153.31 3 15
Average= 4.65 (KJ/cycle)

Cycle 31 GMT 18/ 7/2017 11:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 26 14.58 566 215 0.21 / 143.68 3 3
2 7 2002.52 47 12.90 3195 1937 2.15 / 145.61 3 4
3 13 1603.96 32 13.33 2673 1140 3.29 / 146.75 3 5
4 13 855.72 32 13.81 1640 725 4.02 / 147.48 3 7
5 8 0.20 160 14.35 407 934 4.95 / 148.41 3 15
Average= 4.64 (KJ/cycle)

Cycle 30 GMT 8/ 7/2017 11:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 26 14.62 552 210 0.21 / 138.85 3 3
2 7 2005.12 46 12.92 3205 1905 2.11 / 140.75 3 4
3 13 1605.52 32 13.33 2668 1138 3.25 / 141.89 3 4
4 13 729.04 32 13.92 1457 649 3.90 / 142.54 3 9
5 8 -0.12 160 14.38 402 925 4.83 / 143.46 3 11
Average= 4.63 (KJ/cycle)

Cycle 29 GMT 28/ 6/2017 11:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 26 14.60 535 203 0.20 / 133.95 3 3
2 7 2003.44 46 12.97 3153 1881 2.08 / 135.83 3 3
3 13 1603.00 32 13.34 2657 1134 3.22 / 136.97 3 4
4 13 863.36 32 13.82 1640 725 3.94 / 137.69 3 8
5 8 0.08 160 14.36 411 944 4.89 / 138.64 3 14
Average= 4.62 (KJ/cycle)

Cycle 28 GMT 18/ 6/2017 12:11: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 26 14.60 553 210 0.21 / 128.82 3 3
2 7 2003.32 47 12.97 3151 1921 2.13 / 130.74 3 3
3 13 1726.48 32 13.29 2815 1197 3.33 / 131.94 3 4
4 13 820.32 32 13.86 1584 703 4.03 / 132.64 3 7
5 13 13.24 32 14.61 424 198 4.23 / 132.84 3 10
6 8 -0.20 160 14.32 398 912 5.14 / 133.75 3 14
Average= 4.61 (KJ/cycle)

Cycle 27 GMT 8/ 6/2017 12:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 26 14.57 557 211 0.21 / 124.00 3 3
2 7 2003.64 46 12.99 3195 1909 2.12 / 125.91 3 3
3 13 1596.16 32 13.37 2623 1122 3.24 / 127.03 3 4
4 13 732.56 32 13.93 1462 652 3.89 / 127.68 3 9
5 8 0.32 160 14.38 402 925 4.82 / 128.61 3 14
Average= 4.59 (KJ/cycle)

Cycle 26 GMT 29/ 5/2017 12:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 27 14.63 536 212 0.21 / 119.07 3 3
2 7 2006.48 47 12.97 3199 1950 2.16 / 121.02 3 3
3 13 1608.48 32 13.37 2663 1139 3.30 / 122.16 3 5
4 13 846.36 32 13.85 1617 717 4.02 / 122.87 3 7
5 8 0.32 160 14.38 398 916 4.93 / 123.79 3 10
Average= 4.58 (KJ/cycle)

Cycle 25 GMT 19/ 5/2017 13:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 27 14.64 538 213 0.21 / 114.16 3 3
2 7 2003.76 46 13.02 3191 1911 2.12 / 116.07 3 3
3 13 1729.48 32 13.29 2808 1194 3.32 / 117.26 3 5
4 13 817.44 32 13.89 1563 695 4.01 / 117.96 3 7
5 8 -0.12 160 14.40 390 899 4.91 / 118.85 3 18
Average= 4.57 (KJ/cycle)

Cycle 24 GMT 9/ 5/2017 13:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 27 14.63 548 216 0.22 / 109.34 3 3
2 7 2003.40 47 13.03 3177 1946 2.16 / 111.29 3 3
3 13 1587.28 32 13.40 2623 1125 3.29 / 112.41 3 4
4 13 710.16 32 13.97 1423 636 3.92 / 113.05 3 8
5 8 -0.20 160 14.40 389 896 4.82 / 113.94 3 15
Average= 4.56 (KJ/cycle)

Cycle 23 GMT 29/ 4/2017 14: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 26 14.64 548 209 0.21 / 104.34 3 3
2 3 1033.12 1 14.50 1927 28 0.24 / 104.37 3 3
3 7 2004.56 47 13.04 3191 1956 2.19 / 106.32 3 3
4 13 1729.00 32 13.30 2829 1204 3.40 / 107.53 3 4
5 13 808.36 32 13.91 1557 693 4.09 / 108.22 3 7
6 8 0.12 160 14.40 393 905 4.99 / 109.12 3 11
Average= 4.55 (KJ/cycle)

Cycle 22 GMT 19/ 4/2017 14:28: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 26 14.65 544 207 0.21 / 99.52 3 3
2 7 2007.16 47 13.04 3194 1958 2.16 / 101.48 3 3
3 13 1588.68 32 13.40 2612 1120 3.28 / 102.60 3 4
4 13 711.64 32 13.98 1420 635 3.92 / 103.23 3 8
5 8 -0.28 160 14.42 388 895 4.82 / 104.13 3 12
Average= 4.53 (KJ/cycle)

Cycle 21 GMT 9/ 4/2017 14:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 27 14.66 534 211 0.21 / 94.71 3 3
2 7 2004.00 46 13.07 3182 1913 2.12 / 96.63 3 3
3 13 1599.68 32 13.40 2637 1131 3.26 / 97.76 3 4
4 13 719.72 32 13.98 1437 643 3.90 / 98.40 3 8
5 8 0.12 160 14.40 397 915 4.81 / 99.31 3 15
Average= 4.51 (KJ/cycle)

Cycle 20 GMT 30/ 3/2017 15: 9: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 26 14.67 538 205 0.21 / 90.10 3 3
2 7 2002.88 47 13.06 3170 1946 2.15 / 92.05 3 3
3 13 1482.72 27 13.54 2461 900 3.05 / 92.95 3 6
4 13 685.20 27 14.07 1384 526 3.58 / 93.47 3 6
5 13 10.64 27 14.70 388 154 3.73 / 93.63 3 7
6 8 0.08 160 14.38 380 874 4.60 / 94.50 3 15
Average= 4.50 (KJ/cycle)

Cycle 19 GMT 20/ 3/2017 15: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 25 14.70 548 201 0.20 / 85.44 3 3
2 3 1036.16 1 14.60 1910 28 0.23 / 85.47 3 3
3 7 2003.52 46 13.08 3190 1919 2.15 / 87.39 3 3
4 13 1491.12 27 13.54 2468 902 3.05 / 88.29 3 5
5 13 804.36 27 13.98 1537 580 3.63 / 88.87 3 8
6 13 39.88 27 14.67 433 172 3.80 / 89.04 3 6
7 8 -0.08 160 14.40 371 855 4.66 / 89.90 3 13
Average= 4.49 (KJ/cycle)

Cycle 18 GMT 10/ 3/2017 14:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 25 14.71 520 191 0.19 / 80.42 3 3
2 7 2005.48 46 13.08 3185 1916 2.11 / 82.34 3 3
3 13 1494.40 27 13.53 2483 907 3.01 / 83.24 3 4
4 13 696.64 27 14.06 1399 531 3.55 / 83.77 3 6
5 13 23.64 27 14.68 415 164 3.71 / 83.94 3 7
6 8 -0.20 240 14.33 378 1300 5.01 / 85.24 3 21
Average= 4.49 (KJ/cycle)

Cycle 17 GMT 28/ 2/2017 14:42: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 26 14.70 520 199 0.20 / 75.52 3 3
2 3 970.48 -1 15.56 0 0 0.00 / 75.52 3 3
3 7 2004.88 46 13.11 3172 1913 2.11 / 77.43 3 3
4 13 1499.68 27 13.53 2497 912 3.02 / 78.34 3 4
5 13 806.32 27 13.98 1539 581 3.60 / 78.92 3 6
6 8 -0.08 240 14.37 379 1307 4.91 / 80.23 3 19
Average= 4.46 (KJ/cycle)

Cycle 16 GMT 18/ 2/2017 14:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 26 14.73 536 205 0.21 / 70.68 3 3
2 7 2006.40 46 13.07 3173 1908 2.11 / 72.59 3 3
3 13 1493.08 27 13.52 2471 902 3.01 / 73.49 3 4
4 13 695.56 27 14.07 1384 526 3.54 / 74.02 3 6
5 8 0.08 240 14.37 377 1300 4.84 / 75.32 3 15
Average= 4.43 (KJ/cycle)

Cycle 15 GMT 8/ 2/2017 14:24: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 25 14.73 512 189 0.19 / 65.56 3 3
2 3 1028.76 1 14.60 1899 28 0.22 / 65.59 3 3
3 7 2001.64 47 13.09 3157 1942 2.16 / 67.53 3 3
4 13 1604.96 27 13.48 2622 954 3.11 / 68.48 3 4
5 13 768.64 27 14.01 1501 568 3.68 / 69.05 3 7
6 13 32.84 27 14.70 420 167 3.85 / 69.22 3 8
7 8 0.04 240 14.36 365 1258 5.11 / 70.48 3 17
Average= 4.40 (KJ/cycle)

Cycle 14 GMT 29/ 1/2017 14:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 26 14.75 494 189 0.19 / 60.56 3 3
2 7 2006.68 47 13.06 3171 1946 2.14 / 62.50 3 3
3 13 1488.72 27 13.54 2450 896 3.03 / 63.40 3 4
4 13 801.56 27 13.98 1525 576 3.61 / 63.97 3 6
5 13 35.56 27 14.70 420 167 3.77 / 64.14 3 6
6 8 -0.24 240 14.36 357 1230 5.00 / 65.37 3 17
Average= 4.36 (KJ/cycle)

Cycle 13 GMT 19/ 1/2017 14: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 26 14.75 513 197 0.20 / 55.84 3 3
2 7 2004.16 47 13.09 3154 1940 2.14 / 57.78 3 3
3 13 1370.12 27 13.61 2276 836 2.97 / 58.61 3 4
4 13 705.72 27 14.05 1396 530 3.50 / 59.14 3 6
5 8 -0.08 240 14.41 354 1224 4.73 / 60.37 3 17
Average= 4.31 (KJ/cycle)

Cycle 12 GMT 9/ 1/2017 13:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 25 14.74 507 187 0.19 / 50.89 3 3
2 7 2001.24 46 13.10 3133 1888 2.07 / 52.78 3 3
3 13 1490.88 27 13.54 2444 893 2.97 / 53.68 3 4
4 13 804.12 27 13.97 1530 577 3.55 / 54.25 3 6
5 13 20.16 27 14.72 402 160 3.71 / 54.41 3 6
6 8 0.00 240 14.36 356 1227 4.93 / 55.64 3 21
Average= 4.28 (KJ/cycle)

Cycle 11 GMT 30/12/2016 13:39:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 25 14.76 506 187 0.19 / 45.94 3 3
2 7 2003.76 47 13.08 3159 1942 2.13 / 47.89 3 3
3 13 1480.20 27 13.54 2435 890 3.02 / 48.78 3 4
4 13 790.00 27 13.99 1502 567 3.59 / 49.34 3 6
5 13 16.24 27 14.75 386 154 3.74 / 49.50 3 6
6 8 -0.24 240 14.36 351 1210 4.95 / 50.71 3 19
Average= 4.23 (KJ/cycle)

Cycle 10 GMT 20/12/2016 13:31:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 25 14.75 510 188 0.19 / 41.02 3 3
2 7 2006.92 46 13.07 3157 1898 2.09 / 42.92 3 3
3 13 1491.76 27 13.52 2451 895 2.98 / 43.82 3 4
4 13 807.44 27 13.96 1528 576 3.56 / 44.39 3 7
5 13 18.64 27 14.75 389 155 3.71 / 44.55 3 7
6 8 -0.08 240 14.34 352 1211 4.92 / 45.76 3 21
Average= 4.16 (KJ/cycle)

Cycle 9 GMT 10/12/2016 13:15:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 25 14.76 506 187 0.19 / 36.25 3 3
2 7 2005.48 47 13.06 3158 1938 2.13 / 38.19 3 3
3 13 1468.44 27 13.52 2423 884 3.01 / 39.07 3 4
4 13 779.96 27 13.97 1485 560 3.57 / 39.63 3 6
5 8 0.08 240 14.41 348 1204 4.77 / 40.83 3 18
Average= 4.08 (KJ/cycle)

Cycle 8 GMT 30/11/2016 12:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 25 14.76 505 186 0.19 / 31.51 3 3
2 7 2001.40 46 13.06 3143 1888 2.07 / 33.40 3 3
3 13 1488.28 27 13.49 2452 893 2.97 / 34.29 3 4
4 13 813.44 27 13.94 1524 574 3.54 / 34.87 3 6
5 8 0.04 240 14.41 345 1193 4.73 / 36.06 3 14
Average= 4.01 (KJ/cycle)

Cycle 7 GMT 20/11/2016 12:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 25 14.74 500 184 0.18 / 26.81 3 3
2 7 2003.00 49 13.00 3146 2004 2.19 / 28.81 3 3
3 13 1471.00 25 13.53 2414 817 3.00 / 29.63 3 4
4 13 776.20 25 13.98 1481 518 3.52 / 30.14 3 7
5 8 -0.08 240 14.42 342 1184 4.71 / 31.33 3 17
Average= 3.92 (KJ/cycle)

Cycle 6 GMT 10/11/2016 12:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 23 14.74 501 170 0.17 / 22.06 3 3
2 3 1049.96 1 14.57 1888 28 0.20 / 22.09 3 3
3 7 2001.72 49 12.97 3142 1997 2.19 / 24.08 3 3
4 13 1469.36 25 13.49 2416 815 3.01 / 24.90 3 5
5 13 792.60 25 13.94 1506 525 3.53 / 25.42 3 6
6 8 -0.04 240 14.39 347 1198 4.73 / 26.62 3 14
Average= 3.80 (KJ/cycle)

Cycle 5 GMT 31/10/2016 12: 6: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 24 14.74 490 173 0.17 / 17.32 3 3
2 3 969.72 -1 15.60 0 0 0.00 / 17.32 3 3
3 7 2002.44 49 12.93 3136 1987 2.16 / 19.31 3 3
4 13 1352.36 25 13.52 2254 762 2.92 / 20.07 3 4
5 13 814.04 25 13.89 1522 529 3.45 / 20.60 3 6
6 13 21.84 25 14.76 378 139 3.59 / 20.74 3 6
7 8 -0.04 240 14.35 334 1150 4.74 / 21.89 3 20
Average= 3.65 (KJ/cycle)

Cycle 4 GMT 21/10/2016 11:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 24 14.70 481 170 0.17 / 13.29 3 3
2 3 950.72 -1 15.60 0 0 0.00 / 13.29 3 3
3 7 1515.28 49 13.28 2475 1611 1.78 / 14.90 3 3
4 13 1275.00 25 13.62 2130 725 2.51 / 15.63 3 4
5 13 476.08 25 14.23 1041 370 2.88 / 16.00 3 6
6 8 0.32 240 14.38 334 1153 4.03 / 17.15 3 19
Average= 3.43 (KJ/cycle)

Cycle 3 GMT 20/10/2016 12: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 24 14.65 493 173 0.17 / 9.24 3 3
2 7 1513.52 74 13.03 2437 2350 2.52 / 11.59 3 3
3 13 535.28 25 14.11 1117 394 2.92 / 11.98 3 5
4 8 1.52 240 14.36 330 1137 4.05 / 13.12 3 13
Average= 3.28 (KJ/cycle)

Cycle 2 GMT 19/10/2016 12:38:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 24 14.58 495 173 0.17 / 5.20 3 3
2 7 1516.64 74 12.86 2450 2332 2.50 / 7.53 3 3
3 13 539.76 25 14.04 1128 396 2.90 / 7.93 3 5
4 8 0.04 240 14.33 331 1138 4.04 / 9.07 3 16
Average= 3.02 (KJ/cycle)

Cycle 1 GMT 18/10/2016 13:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 24 14.50 435 151 0.15 / 1.89 3 3
2 10 1015.56 5 14.18 1316 93 0.24 / 1.99 3 3
3 10 1050.48 3 13.90 1424 59 0.30 / 2.05 3 3
4 3 1112.76 3 13.72 1933 80 0.38 / 2.13 3 3
5 3 1072.36 2 13.78 1926 53 0.44 / 2.18 3 3
6 7 1024.52 74 13.02 1767 1702 2.14 / 3.88 3 3
7 8 0.12 240 14.25 335 1146 3.28 / 5.03 3 15
Average= 2.51 (KJ/cycle)

Cycle 0 GMT 18/10/2016 2:41: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 78.64 24 14.24 462 158 0.16 / 0.16 3 3
2 7 88.20 74 13.98 461 477 0.63 / 0.63 3 5
3 8 0.36 240 14.10 327 1107 1.74 / 1.74 3 5
Average= 1.74 (KJ/cycle)