SIO Argo Site:
Pump Diagnostics Page   



Serial= 8383 WMO= 5902398

Return

←PreviousNext→

Cycle 303 GMT 11/10/2022 13: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 44 10.27 703 318 0.32 / 1749.91 2 3
2 3 1056.80 2 8.08 2046 33 0.35 / 1749.94 2 2
3 3 1025.04 1 8.08 2023 16 0.37 / 1749.96 2 2
4 12 1124.56 6 7.48 2114 95 0.46 / 1750.05 2 2
5 12 1232.16 96 7.36 2239 1582 2.04 / 1751.64 2 2
6 7 1236.44 22 7.37 2248 364 2.41 / 1752.00 2 2
7 13 1065.56 47 7.68 2049 740 3.15 / 1752.74 2 2
8 13 633.72 47 8.70 1468 600 3.75 / 1753.34 2 2
9 8 0.16 170 10.40 545 964 4.71 / 1754.30 2 3
Average= 5.77 (KJ/cycle)

Cycle 302 GMT 1/10/2022 20:34: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 45 10.29 708 328 0.33 / 1745.30 2 2
2 3 1016.76 1 8.24 1992 16 0.34 / 1745.32 2 2
3 12 1103.28 6 7.75 2060 96 0.44 / 1745.42 2 2
4 12 1203.20 96 7.58 2198 1599 2.04 / 1747.02 2 2
5 7 1205.40 22 7.62 2202 369 2.41 / 1747.38 2 2
6 13 1023.00 47 7.97 1984 743 3.15 / 1748.13 2 2
7 13 350.88 47 9.49 1079 481 3.63 / 1748.61 2 2
8 8 -0.04 170 10.42 555 983 4.62 / 1749.59 2 3
Average= 5.77 (KJ/cycle)

Cycle 301 GMT 22/ 9/2022 4:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 45 10.34 697 324 0.32 / 1740.53 2 2
2 12 1102.88 6 7.85 2061 97 0.42 / 1740.63 2 2
3 12 1200.16 96 7.71 2218 1642 2.06 / 1742.27 2 2
4 7 1202.44 22 7.74 2210 376 2.44 / 1742.65 2 2
5 13 1015.48 47 8.08 1982 753 3.19 / 1743.40 2 2
6 13 560.12 47 9.07 1375 586 3.78 / 1743.98 2 2
7 8 0.16 170 10.46 558 992 4.77 / 1744.98 2 3
Average= 5.78 (KJ/cycle)

Cycle 300 GMT 12/ 9/2022 11:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 46 10.35 718 342 0.34 / 1733.41 2 2
2 12 1112.76 6 8.07 2117 103 0.44 / 1733.52 2 2
3 12 2001.52 96 6.23 3303 1975 2.42 / 1735.49 2 2
4 7 1997.24 22 6.35 3243 453 2.87 / 1735.94 2 2
5 13 1822.36 47 6.65 3031 947 3.82 / 1736.89 2 2
6 13 1616.80 47 6.95 2811 918 4.74 / 1737.81 2 2
7 13 1176.12 47 7.76 2240 817 5.56 / 1738.63 2 2
8 13 508.48 47 9.24 1331 578 6.13 / 1739.21 2 2
9 8 0.16 170 10.49 561 1000 7.13 / 1740.21 2 3
Average= 5.78 (KJ/cycle)

Cycle 299 GMT 11/ 9/2022 11:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 45 10.42 707 332 0.33 / 1728.57 2 2
2 3 975.00 -1 10.42 707 0 0.00 / 1728.57 2 2
3 3 1028.40 1 8.51 2017 17 0.35 / 1728.59 2 2
4 12 1153.16 6 7.91 2153 102 0.45 / 1728.69 2 2
5 12 1252.32 96 7.78 2290 1710 2.16 / 1730.40 2 2
6 7 1253.72 22 7.78 2286 391 2.55 / 1730.80 2 2
7 13 1061.08 47 8.15 2069 793 3.35 / 1731.59 2 2
8 13 384.04 47 9.57 1143 514 3.86 / 1732.10 2 2
9 8 0.00 170 10.53 542 970 4.83 / 1733.07 2 2
Average= 5.78 (KJ/cycle)

Cycle 298 GMT 1/ 9/2022 18:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 45 10.43 712 334 0.33 / 1723.75 2 2
2 12 1092.16 6 8.00 2069 99 0.43 / 1723.85 2 2
3 12 1199.12 96 7.99 2243 1720 2.15 / 1725.57 2 2
4 7 1201.44 22 8.01 2264 399 2.55 / 1725.97 2 2
5 13 998.52 47 8.38 2004 789 3.34 / 1726.76 2 2
6 13 288.76 47 9.83 1016 469 3.81 / 1727.23 2 2
7 8 0.20 170 10.53 565 1011 4.82 / 1728.24 2 2
Average= 5.78 (KJ/cycle)

Cycle 297 GMT 23/ 8/2022 2:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 44 10.46 735 338 0.34 / 1718.87 2 3
2 3 1023.60 1 8.70 2055 18 0.36 / 1718.89 2 2
3 3 1013.72 1 8.79 1991 18 0.37 / 1718.90 2 2
4 12 1108.76 6 8.29 2097 104 0.48 / 1719.01 2 2
5 12 1210.92 96 8.10 2228 1732 2.21 / 1720.74 2 2
6 7 1213.48 22 8.14 2262 405 2.62 / 1721.15 2 2
7 13 1006.20 47 8.48 1991 794 3.41 / 1721.94 2 2
8 13 276.76 47 9.89 1007 468 3.88 / 1722.41 2 2
9 8 0.16 170 10.56 564 1012 4.89 / 1723.42 2 2
Average= 5.78 (KJ/cycle)

Cycle 296 GMT 13/ 8/2022 10:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 42 10.51 700 309 0.31 / 1711.57 2 3
2 10 1001.60 4 8.74 2003 70 0.38 / 1711.64 2 2
3 12 1105.96 6 8.46 2117 107 0.49 / 1711.75 2 2
4 12 2005.72 96 6.79 3308 2156 2.64 / 1713.90 2 2
5 7 1998.48 22 6.99 3269 503 3.15 / 1714.41 2 2
6 13 1793.44 47 7.13 3066 1027 4.17 / 1715.43 2 2
7 13 1363.24 47 7.87 2520 932 5.11 / 1716.37 2 2
8 13 905.80 47 8.67 1911 779 5.88 / 1717.14 2 2
9 13 85.44 47 10.38 713 348 6.23 / 1717.49 2 2
10 8 0.00 170 10.58 577 1038 7.27 / 1718.53 2 7
Average= 5.79 (KJ/cycle)

Cycle 295 GMT 12/ 8/2022 9:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 44 10.48 709 327 0.33 / 1706.70 2 2
2 3 1012.28 1 8.84 2021 18 0.34 / 1706.71 2 2
3 12 1112.48 6 8.24 2103 104 0.45 / 1706.82 2 2
4 12 1218.40 96 8.18 2242 1761 2.21 / 1708.58 2 2
5 7 1220.00 22 8.23 2262 410 2.62 / 1708.99 2 2
6 13 1012.44 47 8.57 2000 806 3.42 / 1709.79 2 2
7 13 283.16 47 9.95 1002 469 3.89 / 1710.26 2 2
8 8 -0.04 170 10.60 554 998 4.89 / 1711.26 2 3
Average= 5.78 (KJ/cycle)

Cycle 294 GMT 2/ 8/2022 17:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 45 10.53 708 335 0.34 / 1701.78 2 2
2 3 974.56 -1 10.53 708 0 0.00 / 1701.78 2 2
3 3 1028.96 1 8.81 2031 18 0.35 / 1701.80 2 2
4 12 1147.20 6 8.28 2170 108 0.46 / 1701.91 2 2
5 12 1243.44 96 8.19 2292 1802 2.26 / 1703.71 2 2
6 7 1243.40 22 8.21 2313 418 2.68 / 1704.13 2 2
7 13 1029.32 47 8.58 2045 825 3.51 / 1704.95 2 2
8 13 166.36 47 10.23 841 404 3.91 / 1705.36 2 2
9 8 0.28 170 10.61 562 1014 4.92 / 1706.37 2 3
Average= 5.78 (KJ/cycle)

Cycle 293 GMT 24/ 7/2022 1:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 44 10.48 742 342 0.34 / 1696.92 2 2
2 12 1104.76 6 8.31 2114 105 0.45 / 1697.02 2 2
3 12 1206.32 96 8.34 2238 1792 2.24 / 1698.82 2 2
4 7 1206.88 22 8.37 2264 417 2.66 / 1699.23 2 2
5 13 990.88 47 8.73 1998 820 3.48 / 1700.05 2 2
6 13 132.76 47 10.35 766 373 3.85 / 1700.42 2 2
7 8 -0.24 170 10.63 565 1021 4.87 / 1701.45 2 3
Average= 5.79 (KJ/cycle)

Cycle 292 GMT 14/ 7/2022 9: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 44 10.49 713 329 0.33 / 1692.85 2 3
2 3 972.80 -1 10.49 713 0 0.00 / 1692.85 2 3
3 12 1054.04 6 8.66 2078 108 0.44 / 1692.96 2 2
4 12 1170.20 96 8.45 2243 1820 2.26 / 1694.78 2 2
5 7 1156.12 22 8.52 2222 416 2.67 / 1695.19 2 2
6 13 84.28 47 10.44 711 349 3.02 / 1695.54 2 2
7 8 0.20 170 10.64 571 1033 4.05 / 1696.58 2 3
Average= 5.79 (KJ/cycle)

Cycle 291 GMT 13/ 7/2022 9:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 44 10.46 754 347 0.35 / 1687.97 2 2
2 12 1092.80 6 8.46 2076 105 0.45 / 1688.08 2 2
3 12 1189.48 96 8.43 2222 1798 2.25 / 1689.88 2 2
4 7 1189.80 22 8.46 2234 416 2.67 / 1690.29 2 2
5 13 970.28 47 8.84 1947 809 3.48 / 1691.10 2 2
6 13 106.00 47 10.40 746 365 3.84 / 1691.47 2 2
7 8 0.12 170 10.61 585 1055 4.90 / 1692.52 2 3
Average= 5.80 (KJ/cycle)

Cycle 290 GMT 3/ 7/2022 17:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 44 10.53 712 330 0.33 / 1683.16 2 2
2 12 1088.88 6 8.63 2059 107 0.44 / 1683.26 2 2
3 12 1191.88 96 8.48 2237 1821 2.26 / 1685.08 2 2
4 7 1192.80 22 8.48 2238 418 2.68 / 1685.50 2 2
5 13 780.16 47 9.23 1683 730 3.41 / 1686.23 2 2
6 13 65.48 47 10.48 692 341 3.75 / 1686.57 2 2
7 8 0.16 170 10.62 584 1054 4.80 / 1687.63 2 3
Average= 5.80 (KJ/cycle)

Cycle 289 GMT 24/ 6/2022 1: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 44 10.59 724 337 0.34 / 1678.34 2 3
2 12 1098.72 6 8.61 2125 110 0.45 / 1678.45 2 2
3 12 1205.44 96 8.53 2251 1843 2.29 / 1680.29 2 2
4 7 1205.56 22 8.54 2267 426 2.72 / 1680.71 2 2
5 13 782.68 47 9.27 1705 743 3.46 / 1681.46 2 2
6 13 73.56 47 10.50 692 342 3.80 / 1681.80 2 2
7 8 -0.04 170 10.67 566 1027 4.83 / 1682.83 2 9
Average= 5.80 (KJ/cycle)

Cycle 288 GMT 14/ 6/2022 8:37:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 44 10.59 714 333 0.33 / 1671.52 2 2
2 12 1112.20 6 8.79 2168 114 0.45 / 1671.63 2 2
3 12 2004.48 96 7.43 3340 2382 2.83 / 1674.02 2 2
4 7 1995.92 22 7.51 3307 546 3.38 / 1674.56 2 2
5 13 1562.60 47 8.08 2784 1057 4.43 / 1675.62 2 2
6 13 1098.24 47 8.74 2182 896 5.33 / 1676.52 2 2
7 13 173.80 47 10.31 873 423 5.75 / 1676.94 2 2
8 8 0.08 170 10.68 583 1058 6.81 / 1678.00 2 3
Average= 5.81 (KJ/cycle)

Cycle 287 GMT 13/ 6/2022 7:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 44 10.60 725 338 0.34 / 1666.68 2 2
2 12 1103.80 6 8.62 2127 110 0.45 / 1666.79 2 2
3 12 1203.80 96 8.54 2257 1850 2.30 / 1668.64 2 2
4 7 1204.72 22 8.58 2256 426 2.72 / 1669.06 2 2
5 13 784.32 47 9.27 1718 749 3.47 / 1669.81 2 2
6 13 64.72 47 10.51 695 343 3.82 / 1670.15 2 2
7 8 -0.08 170 10.68 569 1033 4.85 / 1671.19 2 6
Average= 5.80 (KJ/cycle)

Cycle 286 GMT 3/ 6/2022 15:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 44 10.61 703 328 0.33 / 1661.77 2 3
2 12 1100.88 6 8.56 2119 109 0.44 / 1661.88 2 2
3 12 1205.24 96 8.61 2249 1859 2.30 / 1663.74 2 2
4 7 1204.80 22 8.67 2269 433 2.73 / 1664.17 2 2
5 13 779.04 47 9.33 1711 750 3.48 / 1664.92 2 2
6 13 125.80 47 10.43 781 383 3.86 / 1665.31 2 2
7 8 0.08 170 10.69 568 1032 4.89 / 1666.34 2 3
Average= 5.81 (KJ/cycle)

Cycle 285 GMT 24/ 5/2022 23:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 44 10.68 704 331 0.33 / 1656.76 2 3
2 12 1120.32 6 8.69 2132 111 0.44 / 1656.87 2 2
3 12 1214.52 96 8.64 2244 1861 2.30 / 1658.73 2 2
4 7 1212.00 22 8.70 2261 433 2.74 / 1659.16 2 2
5 13 992.60 47 9.03 1993 846 3.58 / 1660.01 2 2
6 13 107.24 47 10.48 761 375 3.96 / 1660.39 2 2
7 8 0.12 170 10.70 582 1059 5.02 / 1661.44 2 3
Average= 5.81 (KJ/cycle)

Cycle 284 GMT 15/ 5/2022 7:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 44 10.64 708 331 0.33 / 1649.96 2 3
2 12 1123.96 6 8.93 2146 115 0.45 / 1650.07 2 2
3 12 2003.52 96 7.62 3320 2429 2.88 / 1652.50 2 2
4 7 1994.72 22 7.64 3294 554 3.43 / 1653.05 2 2
5 13 1565.36 47 8.24 2796 1083 4.51 / 1654.14 2 2
6 13 889.28 47 9.18 1900 820 5.33 / 1654.96 2 2
7 13 175.32 47 10.38 868 423 5.75 / 1655.38 2 2
8 8 -0.04 170 10.72 576 1050 6.80 / 1656.43 2 5
Average= 5.81 (KJ/cycle)

Cycle 283 GMT 14/ 5/2022 6:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 44 10.63 695 325 0.33 / 1644.95 2 3
2 12 1099.60 6 8.60 2122 109 0.43 / 1645.06 2 2
3 12 1204.00 96 8.63 2273 1883 2.32 / 1646.94 2 2
4 7 1204.72 22 8.67 2300 439 2.76 / 1647.38 2 2
5 13 986.88 47 9.05 2005 853 3.61 / 1648.24 2 2
6 13 107.72 47 10.50 742 366 3.98 / 1648.60 2 2
7 8 -0.04 170 10.73 560 1021 5.00 / 1649.62 2 3
Average= 5.81 (KJ/cycle)

Cycle 282 GMT 4/ 5/2022 14:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 44 10.61 730 341 0.34 / 1640.08 2 3
2 12 1098.24 6 8.73 2100 110 0.45 / 1640.19 2 2
3 12 1211.96 96 8.66 2278 1894 2.34 / 1642.09 2 2
4 7 1212.32 22 8.73 2288 439 2.78 / 1642.53 2 2
5 13 756.60 47 9.44 1676 744 3.53 / 1643.27 2 2
6 13 55.88 47 10.59 667 332 3.86 / 1643.60 2 2
7 8 0.08 170 10.72 563 1026 4.89 / 1644.63 2 11
Average= 5.81 (KJ/cycle)

Cycle 281 GMT 24/ 4/2022 22:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 44 10.67 702 330 0.33 / 1635.17 2 3
2 12 1105.72 6 8.79 2106 111 0.44 / 1635.28 2 2
3 12 1210.20 96 8.72 2256 1889 2.33 / 1637.17 2 2
4 7 1209.84 22 8.74 2267 436 2.77 / 1637.60 2 2
5 13 776.96 47 9.44 1699 754 3.52 / 1638.36 2 2
6 13 61.20 47 10.59 684 340 3.86 / 1638.70 2 2
7 8 -0.04 170 10.72 573 1044 4.90 / 1639.74 2 6
Average= 5.81 (KJ/cycle)

Cycle 280 GMT 15/ 4/2022 6: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 44 10.68 700 329 0.33 / 1628.38 2 3
2 12 1110.28 6 8.94 2153 115 0.44 / 1628.50 2 2
3 12 2004.28 96 7.67 3346 2464 2.91 / 1630.96 2 2
4 7 1995.12 22 7.82 3298 567 3.48 / 1631.53 2 2
5 13 1544.44 47 8.35 2759 1083 4.56 / 1632.61 2 2
6 13 851.72 47 9.35 1839 808 5.37 / 1633.42 2 2
7 13 75.44 47 10.57 714 355 5.72 / 1633.77 2 2
8 8 -0.08 170 10.73 583 1063 6.78 / 1634.84 2 4
Average= 5.82 (KJ/cycle)

Cycle 279 GMT 14/ 4/2022 5:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 44 10.64 719 337 0.34 / 1623.49 2 3
2 12 1087.68 6 8.75 2072 109 0.45 / 1623.60 2 2
3 12 1192.52 96 8.76 2233 1878 2.32 / 1625.48 2 2
4 7 1191.28 22 8.83 2254 438 2.76 / 1625.92 2 2
5 13 755.28 47 9.47 1673 745 3.51 / 1626.66 2 2
6 13 53.56 47 10.59 673 335 3.84 / 1627.00 2 2
7 8 0.12 170 10.71 579 1054 4.89 / 1628.05 2 3
Average= 5.81 (KJ/cycle)

Cycle 278 GMT 4/ 4/2022 13:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 44 10.68 708 333 0.33 / 1618.59 2 3
2 12 1097.48 6 8.62 2110 109 0.44 / 1618.70 2 2
3 12 1191.76 96 8.73 2259 1893 2.34 / 1620.60 2 2
4 7 1189.36 22 8.82 2266 440 2.77 / 1621.04 2 2
5 13 755.16 47 9.49 1679 749 3.52 / 1621.78 2 2
6 13 55.00 47 10.60 673 335 3.86 / 1622.12 2 2
7 8 0.08 170 10.72 570 1039 4.90 / 1623.16 2 4
Average= 5.82 (KJ/cycle)

Cycle 277 GMT 25/ 3/2022 21: 7: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 44 10.66 722 339 0.34 / 1613.70 2 3
2 12 1087.56 6 8.90 2082 111 0.45 / 1613.82 2 2
3 12 1192.96 96 8.78 2236 1885 2.33 / 1615.70 2 2
4 7 1193.00 22 8.84 2264 440 2.77 / 1616.14 2 2
5 13 754.52 47 9.51 1663 743 3.52 / 1616.88 2 2
6 13 49.64 47 10.60 676 337 3.85 / 1617.22 2 2
7 8 -0.08 170 10.73 570 1040 4.89 / 1618.26 2 4
Average= 5.82 (KJ/cycle)

Cycle 276 GMT 16/ 3/2022 4:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 46 10.59 740 360 0.36 / 1606.74 2 3
2 3 938.76 -1 10.59 740 0 0.00 / 1606.74 2 3
3 12 1127.40 6 8.89 2182 116 0.48 / 1606.86 2 2
4 12 2003.36 96 7.69 3337 2464 2.94 / 1609.32 2 2
5 7 1994.68 22 7.67 3322 561 3.50 / 1609.88 2 2
6 13 1562.44 47 8.35 2765 1085 4.59 / 1610.97 2 2
7 13 1087.16 47 9.01 2169 919 5.50 / 1611.89 2 2
8 13 146.40 47 10.46 825 406 5.91 / 1612.29 2 2
9 8 0.04 170 10.72 590 1075 6.99 / 1613.37 2 3
Average= 5.82 (KJ/cycle)

Cycle 275 GMT 15/ 3/2022 4:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 44 10.62 728 340 0.34 / 1601.82 2 3
2 12 1110.16 6 8.79 2093 110 0.45 / 1601.93 2 2
3 12 1208.12 96 8.75 2254 1893 2.34 / 1603.82 2 2
4 7 1207.04 22 8.76 2272 438 2.78 / 1604.26 2 2
5 13 772.52 47 9.45 1686 749 3.53 / 1605.01 2 2
6 13 32.12 47 10.63 647 323 3.85 / 1605.33 2 2
7 8 0.16 170 10.71 577 1051 4.90 / 1606.38 2 3
Average= 5.82 (KJ/cycle)

Cycle 274 GMT 5/ 3/2022 12: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 44 10.60 743 347 0.35 / 1596.90 2 3
2 12 1111.16 6 8.70 2103 110 0.46 / 1597.01 2 2
3 12 1215.16 96 8.72 2255 1888 2.34 / 1598.90 2 2
4 7 1213.16 22 8.76 2264 436 2.78 / 1599.33 2 2
5 13 775.56 47 9.46 1679 747 3.53 / 1600.08 2 2
6 13 57.84 47 10.60 669 333 3.86 / 1600.41 2 2
7 8 0.36 170 10.69 585 1063 4.92 / 1601.48 2 5
Average= 5.82 (KJ/cycle)

Cycle 273 GMT 23/ 2/2022 19:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 43 10.74 713 329 0.33 / 1591.98 2 3
2 3 1021.24 1 9.61 2071 20 0.35 / 1592.00 2 2
3 12 1114.72 6 8.81 2134 113 0.46 / 1592.11 2 2
4 12 1214.72 96 8.76 2238 1882 2.34 / 1593.99 2 2
5 7 1213.68 22 8.76 2255 435 2.78 / 1594.43 2 2
6 13 761.20 47 9.47 1657 738 3.52 / 1595.17 2 2
7 13 51.28 47 10.59 667 332 3.85 / 1595.50 2 2
8 8 -0.12 170 10.69 580 1054 4.90 / 1596.55 2 3
Average= 5.83 (KJ/cycle)

Cycle 272 GMT 14/ 2/2022 3:42: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 41 10.75 720 317 0.32 / 1585.13 2 2
2 10 1009.48 5 9.44 2058 97 0.41 / 1585.23 2 2
3 12 1082.96 6 9.23 2109 117 0.53 / 1585.34 2 2
4 12 2002.08 96 7.78 3315 2476 3.01 / 1587.82 2 2
5 7 1991.64 22 7.60 3281 549 3.56 / 1588.37 2 2
6 13 1548.04 47 8.40 2743 1083 4.64 / 1589.45 2 2
7 13 851.80 47 9.38 1834 809 5.45 / 1590.26 2 2
8 13 44.64 47 10.70 658 331 5.78 / 1590.59 2 2
9 8 0.04 170 10.78 578 1059 6.84 / 1591.65 2 4
Average= 5.83 (KJ/cycle)

Cycle 271 GMT 13/ 2/2022 2:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 40 10.91 703 307 0.31 / 1580.11 2 3
2 10 1002.92 5 9.71 2012 98 0.40 / 1580.21 2 2
3 12 1101.64 6 9.02 2125 115 0.52 / 1580.32 2 2
4 12 1199.16 96 8.75 2254 1893 2.41 / 1582.22 2 2
5 7 1197.92 22 8.78 2262 437 2.85 / 1582.65 2 2
6 13 768.72 47 9.45 1707 758 3.61 / 1583.41 2 2
7 13 57.60 47 10.68 671 337 3.94 / 1583.75 2 2
8 8 -0.04 170 10.77 582 1066 5.01 / 1584.81 2 5
Average= 5.83 (KJ/cycle)

Cycle 270 GMT 3/ 2/2022 10:39: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 42 11.02 715 331 0.33 / 1575.15 2 3
2 3 1022.20 1 9.83 2064 20 0.35 / 1575.17 2 2
3 12 1112.44 6 9.18 2140 118 0.47 / 1575.29 2 2
4 12 1215.16 96 8.90 2244 1917 2.39 / 1577.21 2 2
5 7 1213.64 22 8.97 2263 447 2.83 / 1577.65 2 2
6 13 766.48 47 9.68 1672 761 3.59 / 1578.41 2 2
7 13 27.88 47 10.88 626 320 3.91 / 1578.73 2 2
8 8 0.16 170 10.91 577 1070 4.98 / 1579.80 2 5
Average= 5.83 (KJ/cycle)

Cycle 269 GMT 24/ 1/2022 18:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 39 11.33 745 329 0.33 / 1570.00 2 3
2 3 1052.08 2 10.08 2155 43 0.37 / 1570.04 2 2
3 3 1019.48 1 10.20 2089 21 0.39 / 1570.07 2 2
4 12 1112.56 6 9.66 2173 126 0.52 / 1570.19 2 2
5 12 1209.76 96 9.28 2251 2005 2.53 / 1572.20 2 2
6 7 1206.72 22 9.23 2264 460 2.98 / 1572.66 2 2
7 13 731.48 47 9.85 1663 770 3.75 / 1573.43 2 2
8 13 2.20 47 11.09 605 315 4.07 / 1573.74 2 2
9 8 -0.16 170 10.98 577 1077 5.15 / 1574.82 2 5
Average= 5.83 (KJ/cycle)

Cycle 268 GMT 15/ 1/2022 2:20: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 39 11.44 742 331 0.33 / 1563.39 2 3
2 3 1032.92 1 10.36 2065 21 0.35 / 1563.41 2 2
3 3 1015.52 1 10.19 2057 21 0.37 / 1563.43 2 2
4 12 1109.28 6 10.08 2193 133 0.51 / 1563.56 2 2
5 12 2002.68 96 8.48 3340 2719 3.23 / 1566.28 2 2
6 7 1990.64 22 8.20 3295 594 3.82 / 1566.87 2 2
7 13 1287.96 47 9.33 2455 1077 4.90 / 1567.95 2 2
8 13 350.20 47 10.81 1124 571 5.47 / 1568.52 2 2
9 8 0.12 170 11.28 600 1151 6.62 / 1569.67 2 3
Average= 5.84 (KJ/cycle)

Cycle 267 GMT 14/ 1/2022 1:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 39 11.70 702 320 0.32 / 1558.35 2 3
2 12 1111.00 6 8.74 2122 111 0.43 / 1558.46 2 2
3 12 1210.12 96 8.74 2215 1858 2.29 / 1560.32 2 2
4 7 1209.84 22 9.06 2243 447 2.74 / 1560.76 2 2
5 13 779.80 47 10.12 1685 801 3.54 / 1561.56 2 2
6 13 48.60 47 11.59 668 364 3.90 / 1561.93 2 2
7 8 -0.04 170 11.38 582 1126 5.03 / 1563.05 2 3
Average= 5.83 (KJ/cycle)

Cycle 266 GMT 4/ 1/2022 9:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 40 11.70 750 351 0.35 / 1553.16 2 2
2 3 966.40 -1 11.70 750 0 0.00 / 1553.16 2 2
3 3 1020.52 1 10.16 2078 21 0.37 / 1553.19 2 2
4 12 1137.28 6 8.91 2158 115 0.49 / 1553.30 2 2
5 12 1242.28 96 8.75 2308 1939 2.43 / 1555.24 2 2
6 7 1242.20 22 9.08 2325 464 2.89 / 1555.70 2 2
7 13 795.00 47 10.18 1765 844 3.74 / 1556.55 2 2
8 13 29.04 47 11.77 657 363 4.10 / 1556.91 2 2
9 8 0.08 170 11.49 570 1113 5.21 / 1558.03 2 7
Average= 5.84 (KJ/cycle)

Cycle 265 GMT 25/12/2021 17: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 38 11.74 744 332 0.33 / 1547.82 2 3
2 3 1039.00 2 10.30 2157 44 0.38 / 1547.87 2 2
3 3 1013.84 1 10.11 2079 21 0.40 / 1547.89 2 2
4 12 1119.76 6 9.44 2184 124 0.52 / 1548.01 2 2
5 12 1217.44 96 9.07 2288 1992 2.51 / 1550.00 2 2
6 7 1215.44 22 9.33 2283 469 2.98 / 1550.47 2 2
7 13 761.08 47 10.37 1722 839 3.82 / 1551.31 2 2
8 13 18.16 47 11.80 655 363 4.18 / 1551.67 2 2
9 8 0.04 170 11.44 586 1140 5.32 / 1552.81 2 4
Average= 5.84 (KJ/cycle)

Cycle 264 GMT 16/12/2021 1: 2:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 38 11.76 742 332 0.33 / 1541.11 2 3
2 3 1029.04 1 10.29 2094 22 0.35 / 1541.13 2 2
3 12 1118.04 6 10.15 2175 132 0.49 / 1541.27 2 2
4 12 2001.16 96 8.33 3360 2687 3.17 / 1543.95 2 2
5 7 1989.68 22 8.04 3341 591 3.76 / 1544.54 2 2
6 13 1309.04 47 9.57 2518 1133 4.90 / 1545.68 2 2
7 13 379.60 47 11.03 1193 618 5.51 / 1546.29 2 2
8 8 0.08 170 11.58 607 1195 6.71 / 1547.49 2 3
Average= 5.84 (KJ/cycle)

Cycle 263 GMT 15/12/2021 0:18:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 35 11.91 770 321 0.32 / 1535.82 2 3
2 3 1070.28 3 10.72 2185 70 0.39 / 1535.89 2 2
3 3 1023.44 1 10.67 2111 23 0.41 / 1535.91 2 2
4 12 1105.64 6 8.63 2111 109 0.52 / 1536.02 2 2
5 12 1204.72 96 8.50 2234 1823 2.35 / 1537.85 2 2
6 7 1204.28 22 9.00 2283 452 2.80 / 1538.30 2 2
7 13 992.28 47 9.80 2032 936 3.73 / 1539.23 2 2
8 13 43.00 47 11.78 683 378 4.11 / 1539.61 2 2
9 8 -0.12 170 11.64 590 1167 5.28 / 1540.78 2 7
Average= 5.84 (KJ/cycle)

Cycle 262 GMT 5/12/2021 8:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 38 12.05 754 345 0.35 / 1530.66 2 2
2 12 1115.68 6 9.35 2142 120 0.47 / 1530.78 2 2
3 12 1220.92 96 8.52 2257 1846 2.31 / 1532.62 2 2
4 7 1220.60 22 9.04 2304 458 2.77 / 1533.08 2 2
5 13 794.84 47 10.49 1764 870 3.64 / 1533.95 2 2
6 13 28.76 47 12.02 658 372 4.01 / 1534.32 2 2
7 8 0.16 170 11.83 585 1176 5.19 / 1535.50 2 5
Average= 5.84 (KJ/cycle)

Cycle 261 GMT 25/11/2021 16: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 35 12.28 761 327 0.33 / 1525.53 2 3
2 10 1012.32 4 11.60 2124 99 0.43 / 1525.62 2 2
3 3 968.52 -1 11.60 2124 0 0.10 / 1525.62 2 2
4 3 1024.80 1 11.17 2122 24 0.45 / 1525.65 2 2
5 12 1130.88 6 9.55 2192 126 0.57 / 1525.77 2 2
6 12 1228.44 96 9.00 2297 1985 2.56 / 1527.76 2 2
7 7 1226.04 22 9.53 2322 487 3.05 / 1528.24 2 2
8 13 753.84 47 10.80 1693 859 3.91 / 1529.10 2 2
9 8 0.08 170 12.01 592 1209 5.11 / 1530.31 2 3
Average= 5.84 (KJ/cycle)

Cycle 260 GMT 15/11/2021 23:54: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 34 12.46 751 318 0.32 / 1518.61 2 3
2 3 1059.20 2 11.27 2134 48 0.37 / 1518.66 2 2
3 3 1023.88 1 11.23 2091 23 0.39 / 1518.68 2 2
4 12 1093.68 6 10.79 2190 142 0.53 / 1518.83 2 2
5 12 2002.88 96 8.65 3366 2795 3.33 / 1521.62 2 2
6 7 1991.12 22 8.43 3354 622 3.95 / 1522.24 2 2
7 13 1254.60 47 10.28 2420 1169 5.12 / 1523.41 2 2
8 13 259.84 47 11.84 1000 556 5.67 / 1523.97 2 2
9 8 0.08 170 12.13 596 1229 6.90 / 1525.20 2 4
Average= 5.84 (KJ/cycle)

Cycle 259 GMT 14/11/2021 23:14: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 34 12.56 750 320 0.32 / 1513.70 2 3
2 3 1031.08 1 11.29 2115 24 0.34 / 1513.72 2 2
3 12 1114.52 6 8.86 2126 113 0.46 / 1513.83 2 2
4 12 1216.16 96 8.72 2251 1884 2.34 / 1515.72 2 2
5 7 1215.76 22 9.47 2293 478 2.82 / 1516.20 2 2
6 13 773.60 47 11.00 1693 875 3.69 / 1517.07 2 2
7 8 0.08 170 12.30 585 1223 4.92 / 1518.30 2 4
Average= 5.84 (KJ/cycle)

Cycle 258 GMT 5/11/2021 7: 7:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 34 12.76 747 324 0.32 / 1508.49 2 2
2 12 1107.16 6 9.12 2070 113 0.44 / 1508.60 2 2
3 12 1213.92 96 8.90 2256 1928 2.36 / 1510.53 2 3
4 7 1213.96 22 9.81 2308 498 2.86 / 1511.03 3 3
5 13 576.84 47 11.63 1441 788 3.65 / 1511.82 2 2
6 13 5.80 47 12.73 612 366 4.02 / 1512.18 2 3
7 8 0.04 170 12.26 573 1194 5.21 / 1513.38 2 10
Average= 5.84 (KJ/cycle)

Cycle 257 GMT 26/10/2021 14:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 33 12.92 739 315 0.32 / 1503.43 2 2
2 3 1034.72 1 12.06 2145 26 0.34 / 1503.45 2 2
3 3 1012.20 1 11.57 2085 24 0.37 / 1503.48 2 2
4 12 1110.92 6 10.21 2151 132 0.50 / 1503.61 2 2
5 12 1210.44 96 9.54 2243 2054 2.55 / 1505.66 2 2
6 7 1207.00 22 10.21 2274 511 3.06 / 1506.17 2 2
7 13 487.96 47 12.08 1312 745 3.81 / 1506.92 2 2
8 8 0.04 170 12.62 581 1246 5.05 / 1508.17 2 5
Average= 5.85 (KJ/cycle)

Cycle 256 GMT 16/10/2021 22:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 33 12.93 731 312 0.31 / 1496.48 2 2
2 3 1026.44 1 11.68 2115 25 0.34 / 1496.50 2 2
3 12 1100.00 6 11.34 2219 151 0.49 / 1496.65 2 2
4 12 2000.04 96 9.47 3374 3067 3.55 / 1499.72 2 2
5 7 1986.16 22 9.62 3292 697 4.25 / 1500.42 2 2
6 13 962.92 47 11.51 2009 1087 5.34 / 1501.50 2 2
7 13 2.52 47 13.07 624 383 5.72 / 1501.89 2 2
8 8 0.08 170 12.55 575 1227 6.95 / 1503.11 2 9
Average= 5.85 (KJ/cycle)

Cycle 255 GMT 15/10/2021 22:15:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 32 13.14 751 316 0.32 / 1491.38 2 2
2 3 1046.96 2 12.03 2128 51 0.37 / 1491.43 2 2
3 3 1012.76 1 11.60 2108 24 0.39 / 1491.46 2 2
4 12 1117.64 6 9.28 2120 118 0.51 / 1491.58 2 2
5 12 1220.08 96 8.71 2254 1885 2.39 / 1493.46 2 2
6 7 1219.56 22 9.61 2320 490 2.88 / 1493.95 2 2
7 13 788.12 47 11.53 1745 946 3.83 / 1494.90 2 2
8 8 -0.08 170 12.76 584 1267 5.10 / 1496.16 2 3
Average= 5.84 (KJ/cycle)

Cycle 254 GMT 6/10/2021 6:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 34 13.32 751 340 0.34 / 1486.20 2 2
2 3 960.16 -1 13.32 751 0 0.00 / 1486.20 2 2
3 3 1012.16 1 11.69 2107 25 0.36 / 1486.22 2 2
4 12 1126.72 6 9.53 2129 122 0.49 / 1486.34 2 2
5 12 1225.44 96 9.13 2252 1974 2.46 / 1488.32 2 2
6 7 1223.28 22 10.07 2304 510 2.97 / 1488.83 2 2
7 13 759.84 47 11.88 1703 951 3.92 / 1489.78 2 2
8 8 0.16 170 12.91 588 1290 5.21 / 1491.07 2 3
Average= 5.85 (KJ/cycle)

Cycle 253 GMT 26/ 9/2021 14:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 30 13.50 790 320 0.32 / 1480.91 2 2
2 10 1021.28 4 12.85 2149 110 0.43 / 1481.02 2 2
3 12 1086.28 6 10.25 2123 131 0.56 / 1481.15 2 2
4 12 1185.68 96 9.63 2248 2078 2.64 / 1483.23 2 2
5 7 1181.20 22 10.45 2273 523 3.16 / 1483.75 2 2
6 13 477.64 47 12.61 1310 776 3.94 / 1484.53 2 2
7 8 0.00 170 13.06 599 1330 5.27 / 1485.86 2 5
Average= 5.85 (KJ/cycle)

Cycle 252 GMT 16/ 9/2021 22:15:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 31 13.53 767 322 0.32 / 1474.05 2 2
2 3 1035.88 1 12.16 2159 26 0.35 / 1474.08 2 2
3 3 1012.08 1 11.60 2107 24 0.37 / 1474.10 2 2
4 12 1109.68 6 11.80 2224 157 0.53 / 1474.26 2 2
5 12 2003.04 96 9.89 3399 3227 3.76 / 1477.48 2 2
6 7 1990.28 22 10.09 3352 744 4.50 / 1478.23 2 2
7 13 720.08 47 12.49 1675 983 5.48 / 1479.21 2 3
8 8 0.20 170 13.22 612 1375 6.86 / 1480.59 2 5
Average= 5.85 (KJ/cycle)

Cycle 251 GMT 15/ 9/2021 21:51: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 32 13.74 785 345 0.35 / 1468.94 2 2
2 12 1082.68 6 8.87 2045 109 0.45 / 1469.04 2 2
3 12 1183.28 96 8.87 2210 1882 2.34 / 1470.93 2 2
4 7 1181.52 22 9.92 2251 491 2.83 / 1471.42 2 2
5 13 741.76 47 12.18 1679 961 3.79 / 1472.38 2 2
6 8 -0.04 170 13.27 598 1349 5.14 / 1473.73 2 3
Average= 5.85 (KJ/cycle)

Cycle 250 GMT 6/ 9/2021 5:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 32 13.85 773 343 0.34 / 1463.79 2 2
2 3 933.80 -1 13.85 773 0 0.00 / 1463.79 2 2
3 12 1103.56 6 9.37 2109 119 0.46 / 1463.91 2 2
4 12 1200.16 96 9.19 2234 1971 2.43 / 1465.88 2 2
5 7 1196.88 22 10.27 2270 513 2.94 / 1466.39 2 2
6 13 526.20 47 12.91 1377 836 3.78 / 1467.23 2 2
7 8 0.08 170 13.47 595 1362 5.14 / 1468.59 2 10
Average= 5.85 (KJ/cycle)

Cycle 249 GMT 27/ 8/2021 13:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 31 13.91 803 346 0.35 / 1458.42 2 2
2 3 1016.32 1 12.31 2167 27 0.37 / 1458.44 2 2
3 12 1104.12 6 10.25 2173 134 0.51 / 1458.58 2 2
4 12 1205.76 96 9.75 2277 2131 2.64 / 1460.71 2 2
5 7 1202.52 22 10.58 2316 539 3.18 / 1461.25 2 2
6 13 483.32 47 13.13 1315 811 3.99 / 1462.06 2 2
7 8 -0.04 170 13.54 603 1388 5.38 / 1463.45 2 6
Average= 5.85 (KJ/cycle)

Cycle 248 GMT 17/ 8/2021 21:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 31 13.92 773 334 0.33 / 1451.47 2 2
2 12 1107.52 6 11.90 2225 159 0.49 / 1451.63 2 2
3 12 2001.04 96 10.06 3389 3273 3.77 / 1454.91 2 2
4 7 1987.40 22 10.40 3364 770 4.54 / 1455.67 2 2
5 13 688.72 47 12.96 1634 995 5.53 / 1456.67 2 2
6 8 0.20 170 13.64 604 1401 6.93 / 1458.07 2 10
Average= 5.86 (KJ/cycle)

Cycle 247 GMT 16/ 8/2021 21:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 30 13.94 784 328 0.33 / 1446.15 2 2
2 3 1039.80 2 12.43 2166 54 0.38 / 1446.20 2 2
3 12 1106.44 6 8.48 2083 106 0.49 / 1446.31 2 2
4 12 1208.60 96 8.96 2242 1928 2.42 / 1448.23 2 2
5 7 1208.48 22 10.08 2309 512 2.93 / 1448.75 2 2
6 13 760.00 47 12.55 1709 1008 3.94 / 1449.75 2 2
7 8 0.20 170 13.65 597 1385 5.32 / 1451.14 2 4
Average= 5.85 (KJ/cycle)

Cycle 246 GMT 7/ 8/2021 5:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 33 13.94 779 358 0.36 / 1440.69 2 3
2 3 956.68 -1 13.94 779 0 0.00 / 1440.69 2 3
3 12 1128.56 6 9.48 2129 121 0.48 / 1440.81 2 2
4 12 1229.08 96 9.38 2282 2055 2.53 / 1442.87 2 2
5 7 1226.24 22 10.29 2331 528 3.06 / 1443.40 2 2
6 13 743.80 47 12.71 1701 1016 4.08 / 1444.41 2 3
7 8 -0.12 170 13.67 605 1406 5.48 / 1445.82 2 12
Average= 5.85 (KJ/cycle)

Cycle 245 GMT 28/ 7/2021 13:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 29 13.98 772 313 0.31 / 1435.40 2 3
2 3 1072.36 3 12.94 2225 86 0.40 / 1435.48 2 2
3 3 1021.08 1 12.58 2165 27 0.43 / 1435.51 2 2
4 12 1092.20 6 10.24 2136 131 0.56 / 1435.64 2 2
5 12 1196.76 96 9.81 2244 2113 2.67 / 1437.76 2 2
6 7 1192.80 22 10.54 2290 531 3.20 / 1438.29 2 2
7 13 273.80 47 13.60 1013 648 3.85 / 1438.93 2 3
8 8 0.20 170 13.73 600 1400 5.25 / 1440.33 2 6
Average= 5.86 (KJ/cycle)

Cycle 244 GMT 18/ 7/2021 21:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 31 13.98 752 326 0.33 / 1428.44 2 2
2 12 1082.72 6 12.03 2171 157 0.48 / 1428.60 2 2
3 12 2005.44 96 9.98 3399 3257 3.74 / 1431.85 2 2
4 7 1992.16 22 10.38 3381 772 4.51 / 1432.62 2 2
5 13 716.48 47 13.03 1660 1017 5.53 / 1433.64 2 2
6 8 0.44 170 13.72 619 1444 6.97 / 1435.08 2 7
Average= 5.86 (KJ/cycle)

Cycle 243 GMT 17/ 7/2021 20:33:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 32 13.98 752 336 0.34 / 1423.75 2 3
2 3 969.80 -1 13.98 752 0 0.00 / 1423.75 2 3
3 12 1051.64 6 9.03 2037 110 0.45 / 1423.86 2 2
4 12 1124.80 96 9.31 2139 1912 2.36 / 1425.77 2 2
5 7 1111.16 22 10.30 2173 492 2.85 / 1426.26 2 2
6 13 48.92 47 13.93 690 452 3.30 / 1426.71 2 2
7 8 0.24 170 13.75 599 1400 4.70 / 1428.11 2 5
Average= 5.85 (KJ/cycle)

Cycle 242 GMT 8/ 7/2021 5: 4: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 33 13.98 781 360 0.36 / 1418.39 2 2
2 3 912.32 -2 13.98 781 0 0.00 / 1418.39 2 2
3 12 1141.44 6 9.68 2132 124 0.48 / 1418.51 2 2
4 12 1244.16 96 9.51 2320 2118 2.60 / 1420.63 2 2
5 7 1241.44 22 10.41 2355 539 3.14 / 1421.17 2 2
6 13 539.92 47 13.25 1381 860 4.00 / 1422.03 2 2
7 8 -0.20 170 13.79 590 1383 5.38 / 1423.41 2 6
Average= 5.86 (KJ/cycle)

Cycle 241 GMT 28/ 6/2021 13: 7: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 31 13.97 774 335 0.34 / 1413.12 2 3
2 3 1051.44 2 12.97 2195 57 0.39 / 1413.17 2 2
3 12 1100.64 6 10.31 2151 133 0.53 / 1413.31 2 2
4 12 1204.36 96 9.95 2260 2159 2.68 / 1415.47 2 2
5 7 1200.16 22 10.68 2307 542 3.23 / 1416.01 2 2
6 13 262.88 47 13.69 989 636 3.86 / 1416.64 2 3
7 8 0.04 170 13.83 587 1380 5.24 / 1418.02 2 7
Average= 5.86 (KJ/cycle)

Cycle 240 GMT 18/ 6/2021 20:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 33 13.95 772 355 0.36 / 1406.07 2 3
2 3 955.48 -1 13.95 772 0 0.00 / 1406.07 2 3
3 12 1138.28 6 12.03 2269 164 0.52 / 1406.24 2 2
4 12 2001.64 96 10.17 3399 3319 3.84 / 1409.56 2 2
5 7 1988.52 22 10.52 3400 787 4.62 / 1410.34 2 2
6 13 691.60 47 13.13 1620 1000 5.62 / 1411.34 2 2
7 8 0.00 170 13.80 614 1440 7.06 / 1412.78 2 8
Average= 5.86 (KJ/cycle)

Cycle 239 GMT 17/ 6/2021 20:37:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 31 14.01 747 324 0.32 / 1400.66 2 3
2 3 1017.44 1 12.17 2111 26 0.35 / 1400.69 2 2
3 12 1105.00 6 8.58 2051 106 0.46 / 1400.80 2 2
4 12 1211.72 96 9.23 2237 1982 2.44 / 1402.78 2 2
5 7 1210.60 22 10.30 2292 519 2.96 / 1403.30 2 2
6 13 748.08 47 12.83 1678 1012 3.97 / 1404.31 2 2
7 8 0.20 170 13.79 601 1409 5.38 / 1405.72 2 11
Average= 5.86 (KJ/cycle)

Cycle 238 GMT 8/ 6/2021 4:52: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 33 14.01 757 350 0.35 / 1395.39 2 3
2 3 946.16 -1 14.01 757 0 0.00 / 1395.39 2 3
3 12 1118.20 6 9.53 2081 119 0.47 / 1395.50 2 2
4 12 1223.52 96 9.59 2257 2078 2.55 / 1397.58 2 2
5 7 1219.76 22 10.47 2306 531 3.08 / 1398.11 2 2
6 13 526.16 47 13.29 1355 846 3.92 / 1398.96 2 2
7 8 0.00 170 13.83 587 1380 5.30 / 1400.34 2 11
Average= 5.86 (KJ/cycle)

Cycle 237 GMT 29/ 5/2021 12:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 27 14.04 748 284 0.28 / 1390.10 2 3
2 10 1031.36 5 13.24 2105 139 0.42 / 1390.24 2 2
3 12 1108.24 6 10.14 2131 130 0.55 / 1390.37 2 2
4 12 1207.96 96 9.93 2243 2138 2.69 / 1392.51 2 2
5 7 1203.92 22 10.69 2269 534 3.22 / 1393.04 2 2
6 13 253.80 47 13.72 971 626 3.85 / 1393.67 2 3
7 8 -0.08 170 13.88 580 1369 5.22 / 1395.04 2 8
Average= 5.86 (KJ/cycle)

Cycle 236 GMT 19/ 5/2021 20:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 33 14.00 739 341 0.34 / 1382.87 2 3
2 12 1083.88 6 12.02 2154 155 0.50 / 1383.02 2 2
3 12 2002.24 96 10.13 3359 3267 3.76 / 1386.29 2 2
4 7 1988.80 22 10.53 3321 769 4.53 / 1387.06 2 2
5 13 692.92 47 13.17 1589 984 5.52 / 1388.04 2 2
6 13 1.44 47 14.06 632 418 5.93 / 1388.46 2 3
7 8 -0.04 170 13.68 584 1358 7.29 / 1389.82 2 12
Average= 5.86 (KJ/cycle)

Cycle 235 GMT 18/ 5/2021 20: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 33 14.02 745 345 0.34 / 1377.60 2 3
2 3 939.44 -1 14.02 745 0 0.00 / 1377.60 2 3
3 12 1131.20 6 8.85 2102 112 0.46 / 1377.71 2 2
4 12 1226.04 96 9.34 2263 2029 2.49 / 1379.74 2 2
5 7 1221.92 22 10.40 2294 525 3.01 / 1380.26 2 2
6 13 549.52 47 13.22 1399 869 3.88 / 1381.13 2 2
7 8 0.04 170 13.86 590 1390 5.27 / 1382.52 2 11
Average= 5.86 (KJ/cycle)

Cycle 234 GMT 9/ 5/2021 4: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 33 14.03 727 337 0.34 / 1372.75 2 3
2 3 895.28 -2 14.03 727 0 0.00 / 1372.75 2 3
3 3 968.52 -1 14.03 727 0 0.00 / 1372.75 2 3
4 12 1104.88 6 9.70 2106 123 0.46 / 1372.87 2 2
5 12 1179.76 96 9.73 2190 2046 2.50 / 1374.91 2 2
6 7 1166.84 22 10.59 2206 514 3.02 / 1375.43 2 2
7 13 53.36 47 13.97 680 446 3.47 / 1375.87 2 3
8 8 0.08 170 13.88 585 1380 4.85 / 1377.25 2 11
Average= 5.86 (KJ/cycle)

Cycle 233 GMT 29/ 4/2021 12:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 33 13.98 773 357 0.36 / 1367.16 2 3
2 12 1086.64 6 10.13 2133 130 0.49 / 1367.29 2 2
3 12 1181.80 96 10.02 2235 2150 2.64 / 1369.44 2 2
4 7 1178.44 22 10.72 2267 535 3.17 / 1369.97 2 2
5 13 241.12 47 13.73 958 618 3.79 / 1370.59 2 3
6 13 14.56 47 14.03 641 423 4.21 / 1371.01 2 3
7 8 -0.04 170 13.84 593 1395 5.61 / 1372.41 2 14
Average= 5.86 (KJ/cycle)

Cycle 232 GMT 19/ 4/2021 20:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 33 13.99 757 349 0.35 / 1360.20 2 3
2 12 1095.56 6 12.04 2189 158 0.51 / 1360.36 2 2
3 12 2002.20 96 10.16 3352 3269 3.78 / 1363.63 2 2
4 7 1988.24 22 10.51 3363 778 4.55 / 1364.41 2 2
5 13 694.24 47 13.15 1630 1007 5.56 / 1365.41 2 2
6 8 0.20 170 13.90 588 1389 6.95 / 1366.80 2 7
Average= 5.87 (KJ/cycle)

Cycle 231 GMT 18/ 4/2021 19:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 33 14.03 741 343 0.34 / 1354.86 2 3
2 12 1082.96 6 8.93 2005 107 0.45 / 1354.97 2 2
3 12 1186.72 96 9.37 2212 1990 2.44 / 1356.96 2 2
4 7 1185.44 22 10.42 2261 518 2.96 / 1357.48 2 2
5 13 706.92 47 12.94 1626 989 3.95 / 1358.46 2 2
6 8 -0.12 170 13.87 588 1386 5.33 / 1359.85 2 9
Average= 5.86 (KJ/cycle)

Cycle 230 GMT 9/ 4/2021 3:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 32 14.03 719 323 0.32 / 1349.58 2 3
2 3 1024.60 1 12.50 2094 26 0.35 / 1349.60 2 2
3 12 1105.20 6 9.20 2092 115 0.46 / 1349.72 2 2
4 12 1206.08 96 9.65 2235 2071 2.53 / 1351.79 2 2
5 7 1203.48 22 10.55 2271 527 3.06 / 1352.32 2 2
6 13 489.24 47 13.38 1302 819 3.88 / 1353.14 2 2
7 8 0.20 170 13.89 585 1381 5.26 / 1354.52 2 6
Average= 5.86 (KJ/cycle)

Cycle 229 GMT 30/ 3/2021 11:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 33 14.03 729 338 0.34 / 1344.36 2 3
2 3 972.04 -1 14.03 729 0 0.00 / 1344.36 2 3
3 3 1028.56 1 12.85 2124 27 0.36 / 1344.39 2 2
4 12 1134.68 6 9.83 2165 128 0.49 / 1344.52 2 2
5 12 1231.60 96 9.93 2279 2173 2.67 / 1346.69 2 2
6 7 1227.08 22 10.70 2324 547 3.21 / 1347.24 2 2
7 13 276.24 47 13.70 994 640 3.85 / 1347.88 2 3
8 8 -0.04 170 13.91 582 1376 5.23 / 1349.25 2 8
Average= 5.87 (KJ/cycle)

Cycle 228 GMT 20/ 3/2021 19:35: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 32 13.98 741 331 0.33 / 1337.47 2 3
2 12 1109.40 6 11.99 2181 157 0.49 / 1337.62 2 2
3 12 2002.80 96 10.14 3344 3255 3.74 / 1340.88 2 2
4 7 1989.32 22 10.55 3332 773 4.52 / 1341.65 2 3
5 13 679.04 47 13.22 1566 973 5.49 / 1342.63 2 3
6 8 0.12 170 13.91 592 1400 6.89 / 1344.03 2 7
Average= 5.87 (KJ/cycle)

Cycle 227 GMT 19/ 3/2021 19:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 32 14.00 736 330 0.33 / 1332.22 2 3
2 3 1025.84 1 12.42 2088 26 0.36 / 1332.25 2 2
3 12 1112.88 6 8.55 2026 104 0.46 / 1332.35 2 2
4 12 1219.68 96 9.35 2242 2012 2.47 / 1334.36 2 2
5 7 1218.64 22 10.54 2267 526 3.00 / 1334.89 2 2
6 13 537.24 47 13.29 1375 859 3.86 / 1335.75 2 3
7 8 0.16 170 13.88 589 1390 5.25 / 1337.14 2 8
Average= 5.86 (KJ/cycle)

Cycle 226 GMT 10/ 3/2021 3:11: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 33 14.00 758 350 0.35 / 1327.18 2 3
2 12 1097.12 6 9.17 2079 114 0.46 / 1327.30 2 2
3 12 1198.56 96 9.75 2225 2083 2.55 / 1329.38 2 2
4 7 1193.88 22 10.63 2240 524 3.07 / 1329.90 2 2
5 13 249.88 47 13.73 933 602 3.67 / 1330.51 2 3
6 8 0.00 170 13.89 586 1384 5.06 / 1331.89 2 6
Average= 5.87 (KJ/cycle)

Cycle 225 GMT 28/ 2/2021 11: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 32 14.07 733 330 0.33 / 1321.92 3 3
2 3 1017.72 1 12.72 2143 27 0.36 / 1321.95 2 2
3 12 1114.44 4 9.41 2110 79 0.44 / 1322.03 2 2
4 12 1224.60 96 9.95 2267 2165 2.60 / 1324.20 2 2
5 7 1222.76 22 10.79 2303 547 3.15 / 1324.74 2 2
6 13 505.48 42 13.48 1292 731 3.88 / 1325.47 2 3
7 8 0.04 170 13.92 574 1358 5.24 / 1326.83 2 8
Average= 5.87 (KJ/cycle)

Cycle 224 GMT 18/ 2/2021 18:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 32 14.08 718 324 0.32 / 1314.76 3 3
2 12 1096.36 4 11.87 2180 104 0.43 / 1314.86 2 2
3 12 2001.80 96 10.17 3357 3278 3.70 / 1318.14 2 2
4 7 1988.80 22 10.62 3322 776 4.48 / 1318.91 2 2
5 13 711.08 42 13.26 1608 896 5.38 / 1319.81 2 3
6 13 27.36 42 14.03 655 386 5.76 / 1320.20 2 3
7 8 0.08 170 13.90 592 1399 7.16 / 1321.59 2 11
Average= 5.87 (KJ/cycle)

Cycle 223 GMT 17/ 2/2021 18:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 33 14.02 721 334 0.33 / 1309.18 3 3
2 3 957.28 -1 14.02 721 0 0.00 / 1309.18 3 3
3 3 1012.56 1 12.01 2094 25 0.36 / 1309.20 2 2
4 12 1128.76 4 6.46 2009 52 0.41 / 1309.26 2 2
5 12 1227.16 96 9.25 2232 1982 2.39 / 1311.24 2 2
6 7 1226.72 22 10.65 2270 532 2.92 / 1311.77 2 2
7 13 775.96 42 13.05 1688 925 3.85 / 1312.70 2 2
8 13 16.40 42 14.02 634 373 4.22 / 1313.07 2 3
9 8 0.00 170 13.86 579 1364 5.59 / 1314.43 2 11
Average= 5.87 (KJ/cycle)

Cycle 222 GMT 8/ 2/2021 2:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 34 14.02 723 345 0.34 / 1303.63 3 3
2 3 960.36 -1 14.02 723 0 0.00 / 1303.63 3 3
3 12 1131.72 4 7.49 2044 61 0.41 / 1303.70 2 2
4 12 1238.20 96 9.65 2278 2110 2.52 / 1305.81 2 2
5 7 1236.16 22 10.73 2318 547 3.06 / 1306.35 2 2
6 13 517.96 42 13.42 1350 761 3.82 / 1307.11 2 3
7 13 1.08 42 14.04 617 364 4.19 / 1307.48 2 3
8 8 -0.04 170 13.73 586 1368 5.56 / 1308.85 2 14
Average= 5.87 (KJ/cycle)

Cycle 221 GMT 29/ 1/2021 10:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 33 14.10 721 335 0.34 / 1298.48 3 3
2 3 982.08 -1 14.10 721 0 0.00 / 1298.48 3 3
3 3 1042.36 2 13.07 2122 55 0.39 / 1298.54 2 2
4 12 1109.12 4 8.65 2031 70 0.46 / 1298.61 2 2
5 12 1218.48 96 10.03 2247 2164 2.62 / 1300.77 2 2
6 7 1215.40 22 10.88 2288 548 3.17 / 1301.32 2 2
7 13 281.16 42 13.75 990 572 3.74 / 1301.89 2 3
8 8 0.12 170 13.90 591 1397 5.14 / 1303.29 2 7
Average= 5.87 (KJ/cycle)

Cycle 220 GMT 19/ 1/2021 18:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 32 14.02 719 323 0.32 / 1291.65 2 3
2 3 981.68 -1 14.02 719 0 0.00 / 1291.65 2 3
3 3 1031.64 1 12.35 2107 26 0.35 / 1291.68 2 2
4 12 1130.28 4 11.84 2212 105 0.45 / 1291.78 2 2
5 12 2002.00 96 10.24 3350 3293 3.75 / 1295.07 2 2
6 7 1990.08 22 10.59 3359 783 4.53 / 1295.86 2 2
7 13 700.04 42 13.31 1602 896 5.42 / 1296.75 2 2
8 8 0.16 170 13.96 589 1398 6.82 / 1298.15 2 9
Average= 5.87 (KJ/cycle)

Cycle 219 GMT 18/ 1/2021 18:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 32 14.03 727 326 0.33 / 1286.08 2 3
2 3 1035.00 1 12.50 2102 26 0.35 / 1286.11 2 2
3 12 1118.56 4 4.96 1941 39 0.39 / 1286.15 2 3
4 12 1227.08 96 9.20 2236 1975 2.37 / 1288.12 2 2
5 7 1225.96 22 10.70 2304 542 2.91 / 1288.66 2 2
6 13 767.00 42 13.12 1690 931 3.84 / 1289.59 2 2
7 13 11.72 42 14.03 627 369 4.21 / 1289.96 2 3
8 8 -0.08 170 13.90 577 1363 5.57 / 1291.33 2 11
Average= 5.87 (KJ/cycle)

Cycle 218 GMT 9/ 1/2021 2:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 31 14.03 755 328 0.33 / 1280.85 2 3
2 3 1050.80 2 12.76 2146 55 0.38 / 1280.90 2 2
3 12 1107.44 4 6.83 1967 54 0.44 / 1280.95 2 2
4 12 1212.20 96 9.80 2249 2116 2.55 / 1283.07 2 2
5 7 1210.92 22 10.79 2303 547 3.10 / 1283.62 2 2
6 13 510.36 42 13.46 1342 759 3.86 / 1284.38 2 3
7 8 0.04 170 13.94 582 1379 5.24 / 1285.75 2 9
Average= 5.87 (KJ/cycle)

Cycle 217 GMT 30/12/2020 10:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 1002.48 15 13.34 2070 414 0.41 / 1274.92 2 2
2 10 1083.36 12 13.36 2185 350 0.76 / 1275.27 2 2
3 10 1135.44 7 13.44 2279 214 0.98 / 1275.49 2 2
4 3 1175.56 7 13.09 2326 213 1.19 / 1275.70 2 2
5 3 1071.28 3 13.29 2162 86 1.28 / 1275.79 2 2
6 12 1152.72 96 9.99 2161 2072 3.35 / 1277.86 2 2
7 7 1152.76 22 11.01 2241 543 3.89 / 1278.40 2 2
8 13 423.12 42 13.59 1239 707 4.60 / 1279.11 2 3
9 8 0.08 170 13.92 595 1408 6.01 / 1280.52 2 6
Average= 5.87 (KJ/cycle)

Cycle 216 GMT 20/12/2020 19: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 33 13.98 743 343 0.34 / 1267.92 2 3
2 3 973.44 -1 13.98 743 0 0.00 / 1267.92 2 3
3 3 1025.44 1 12.19 2082 25 0.37 / 1267.95 2 2
4 12 1132.16 4 11.80 2238 106 0.47 / 1268.05 2 2
5 12 2004.56 96 10.35 3368 3346 3.82 / 1271.40 2 2
6 7 1990.80 22 10.71 3361 792 4.61 / 1272.19 2 2
7 13 684.36 42 13.33 1605 899 5.51 / 1273.09 2 2
8 8 0.12 170 13.94 599 1420 6.93 / 1274.51 2 7
Average= 5.87 (KJ/cycle)

Cycle 215 GMT 19/12/2020 18:59: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 31 13.98 746 323 0.32 / 1262.83 2 3
2 3 1015.36 1 12.09 2086 25 0.35 / 1262.86 2 2
3 12 1111.80 5 8.44 2030 86 0.43 / 1262.94 2 2
4 12 1219.20 36 10.50 2277 861 1.29 / 1263.80 2 2
5 7 1224.64 22 11.42 2286 574 1.87 / 1264.38 2 2
6 13 1094.96 42 12.81 2160 1162 3.03 / 1265.54 2 2
7 13 390.36 42 13.64 1161 665 3.70 / 1266.20 2 2
8 8 0.16 170 13.92 581 1375 5.07 / 1267.58 2 5
Average= 5.87 (KJ/cycle)

Cycle 214 GMT 10/12/2020 2:38: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 381.60 -13 0.00 0 0 0.00 / 1257.26 2 2
2 3 751.88 -5 0.00 0 0 0.00 / 1257.26 2 2
3 7 1420.00 22 12.93 2632 749 0.75 / 1258.01 2 2
4 13 1479.64 42 12.57 2668 1409 2.16 / 1259.42 2 2
5 13 1260.48 42 12.81 2329 1253 3.41 / 1260.67 2 2
6 13 106.64 42 13.94 765 448 3.86 / 1261.12 2 2
7 8 0.04 170 13.93 587 1390 5.25 / 1262.51 2 14
Average= 5.87 (KJ/cycle)

Cycle 213 GMT 9/12/2020 19: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 376.52 -13 0.00 0 0 0.00 / 1251.92 2 2
2 3 753.08 -5 0.00 0 0 0.00 / 1251.92 2 2
3 7 1436.12 22 12.98 2630 751 0.75 / 1252.67 2 2
4 13 1489.60 42 12.53 2720 1431 2.18 / 1254.11 2 2
5 13 1283.56 42 12.75 2404 1287 3.47 / 1255.39 2 2
6 13 114.92 42 13.92 787 460 3.93 / 1255.85 2 2
7 8 0.12 170 13.92 594 1406 5.34 / 1257.26 2 8
Average= 5.88 (KJ/cycle)

Cycle 212 GMT 9/12/2020 11:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 33 14.01 738 341 0.34 / 1245.85 2 3
2 12 1087.28 5 11.90 2164 129 0.47 / 1245.98 2 2
3 12 2003.96 36 10.71 3422 1319 1.79 / 1247.30 2 2
4 7 1999.68 22 10.81 3400 809 2.60 / 1248.11 2 2
5 13 1782.08 42 12.17 3132 1601 4.20 / 1249.71 2 2
6 13 550.80 42 13.46 1407 795 4.99 / 1250.51 2 2
7 8 0.16 170 13.89 600 1417 6.41 / 1251.92 2 7
Average= 5.88 (KJ/cycle)

Cycle 211 GMT 8/12/2020 10:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 32 13.97 763 341 0.34 / 1240.70 2 3
2 3 960.68 -1 13.97 763 0 0.00 / 1240.70 2 3
3 3 1015.40 1 11.99 2064 25 0.37 / 1240.73 2 2
4 12 1133.96 5 8.93 2076 93 0.46 / 1240.82 2 2
5 12 1232.96 36 10.53 2304 873 1.33 / 1241.69 2 2
6 7 1238.76 22 11.43 2351 591 1.92 / 1242.29 2 2
7 13 1100.48 42 12.78 2163 1161 3.08 / 1243.45 2 2
8 13 392.92 42 13.61 1178 673 3.76 / 1244.12 2 3
9 8 -0.04 170 13.90 589 1392 5.15 / 1245.51 2 7
Average= 5.88 (KJ/cycle)

Cycle 210 GMT 28/11/2020 17:59: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 378.12 -13 0.00 0 0 0.00 / 1235.19 2 2
2 3 737.96 -6 0.00 0 0 0.00 / 1235.19 2 2
3 7 1407.68 22 12.98 2580 737 0.74 / 1235.93 2 2
4 13 1473.28 42 12.58 2653 1402 2.14 / 1237.33 2 2
5 13 1059.24 42 12.94 2104 1143 3.28 / 1238.47 2 3
6 13 139.96 42 13.89 813 474 3.76 / 1238.95 2 2
7 8 0.04 170 13.89 599 1414 5.17 / 1240.36 2 6
Average= 5.88 (KJ/cycle)

Cycle 209 GMT 28/11/2020 10:10:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 381.60 -13 0.00 0 0 0.00 / 1229.86 2 2
2 3 746.72 -5 0.00 0 0 0.00 / 1229.86 2 2
3 7 1430.44 22 12.97 2658 758 0.76 / 1230.62 2 2
4 13 1483.72 42 12.56 2669 1408 2.17 / 1232.03 2 2
5 13 1276.76 42 12.76 2379 1275 3.44 / 1233.30 2 2
6 13 117.80 42 13.90 798 466 3.91 / 1233.77 2 2
7 8 0.24 170 13.90 603 1425 5.33 / 1235.19 2 6
Average= 5.88 (KJ/cycle)

Cycle 208 GMT 28/11/2020 2:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 33 13.98 744 343 0.34 / 1223.86 2 3
2 12 1081.56 5 11.98 2152 129 0.47 / 1223.99 2 2
3 12 2002.40 36 10.73 3402 1314 1.79 / 1225.30 2 2
4 7 1998.32 22 10.81 3415 812 2.60 / 1226.12 2 2
5 13 1580.08 42 12.39 2836 1476 4.07 / 1227.59 2 2
6 13 618.04 42 13.36 1513 849 4.92 / 1228.44 2 2
7 8 0.16 170 13.88 601 1418 6.34 / 1229.86 2 8
Average= 5.88 (KJ/cycle)

Cycle 207 GMT 27/11/2020 1:47:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 30 13.92 770 322 0.32 / 1218.68 2 3
2 3 1039.48 2 12.63 2102 53 0.37 / 1218.73 2 2
3 3 1019.88 1 12.40 2052 25 0.40 / 1218.76 2 2
4 12 1109.40 5 9.95 2071 103 0.50 / 1218.86 2 2
5 12 1215.88 36 10.67 2273 873 1.38 / 1219.74 2 2
6 7 1221.56 22 11.52 2306 584 1.96 / 1220.32 2 2
7 13 1080.80 42 12.80 2138 1149 3.11 / 1221.47 2 2
8 13 390.04 42 13.60 1159 662 3.77 / 1222.13 2 3
9 8 -0.28 170 13.89 587 1386 5.16 / 1223.52 2 7
Average= 5.88 (KJ/cycle)

Cycle 206 GMT 17/11/2020 9:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 379.28 -13 0.00 0 0 0.00 / 1213.08 2 2
2 3 748.68 -5 0.00 0 0 0.00 / 1213.08 2 2
3 7 1438.96 22 12.97 2660 759 0.76 / 1213.84 2 2
4 13 1476.68 42 12.55 2670 1407 2.17 / 1215.25 2 2
5 13 1269.56 42 12.77 2343 1257 3.42 / 1216.50 2 2
6 13 100.48 42 13.93 767 449 3.87 / 1216.95 2 3
7 8 0.20 170 13.91 596 1409 5.28 / 1218.36 2 9
Average= 5.89 (KJ/cycle)

Cycle 205 GMT 17/11/2020 1:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 378.96 -13 0.00 0 0 0.00 / 1207.74 2 2
2 3 747.64 -5 0.00 0 0 0.00 / 1207.74 2 2
3 7 1409.72 22 13.04 2638 757 0.76 / 1208.50 2 2
4 13 1475.80 42 12.54 2687 1415 2.17 / 1209.92 2 2
5 13 1258.64 42 12.74 2390 1279 3.45 / 1211.19 2 2
6 13 103.88 42 13.92 775 453 3.90 / 1211.65 2 3
7 8 0.12 170 13.90 606 1432 5.34 / 1213.08 2 7
Average= 5.89 (KJ/cycle)

Cycle 204 GMT 16/11/2020 18:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 31 13.93 781 337 0.34 / 1201.11 2 3
2 3 1026.88 1 12.26 2062 25 0.36 / 1201.13 2 2
3 3 1014.24 1 11.83 2037 24 0.39 / 1201.16 2 2
4 12 1112.20 5 11.98 2194 131 0.52 / 1201.29 2 2
5 12 2004.20 36 10.70 3418 1317 1.83 / 1202.60 2 2
6 7 1999.96 22 10.83 3394 809 2.64 / 1203.41 2 2
7 13 1793.08 42 12.10 3152 1602 4.25 / 1205.01 2 3
8 13 780.12 42 13.17 1738 961 5.21 / 1205.98 2 2
9 13 1.04 42 14.03 642 378 5.58 / 1206.35 2 3
10 8 0.08 170 13.74 595 1390 6.97 / 1207.74 2 9
Average= 5.89 (KJ/cycle)

Cycle 203 GMT 15/11/2020 17:26: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 33 13.94 768 353 0.35 / 1196.92 2 3
2 3 907.56 -2 13.94 768 0 0.00 / 1196.92 2 3
3 12 1059.64 5 10.21 2016 103 0.46 / 1197.02 2 2
4 12 1144.76 36 10.71 2210 852 1.31 / 1197.87 2 2
5 7 1140.88 22 11.60 2254 575 1.88 / 1198.45 2 2
6 13 688.36 42 13.22 1614 896 2.78 / 1199.34 2 3
7 8 -0.16 170 13.83 606 1425 4.20 / 1200.77 2 8
Average= 5.89 (KJ/cycle)

Cycle 202 GMT 6/11/2020 1:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 386.68 -13 0.00 0 0 0.00 / 1191.26 2 2
2 3 741.88 -6 0.00 0 0 0.00 / 1191.26 2 2
3 7 1414.48 22 12.96 2634 751 0.75 / 1192.01 2 2
4 13 1486.12 42 12.50 2733 1435 2.19 / 1193.44 2 2
5 13 1273.64 42 12.73 2396 1281 3.47 / 1194.73 2 2
6 13 112.32 42 13.92 781 457 3.92 / 1195.18 2 2
7 8 0.04 170 13.94 583 1382 5.31 / 1196.56 2 10
Average= 5.89 (KJ/cycle)

Cycle 201 GMT 5/11/2020 17:59: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 32 13.92 767 342 0.34 / 1186.67 2 2
2 3 282.28 -15 13.92 767 0 0.00 / 1186.67 2 2
3 3 595.28 -9 13.92 767 0 0.00 / 1186.67 2 2
4 7 1456.40 22 12.89 2750 780 1.12 / 1187.45 2 2
5 13 1347.28 42 12.61 2529 1339 2.46 / 1188.79 2 2
6 13 881.76 42 13.06 1895 1039 3.50 / 1189.83 2 3
7 8 0.20 170 13.88 606 1430 4.93 / 1191.26 2 8
Average= 5.90 (KJ/cycle)

Cycle 200 GMT 5/11/2020 9:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 32 13.91 767 341 0.34 / 1180.14 2 2
2 3 975.08 -1 13.91 767 0 0.00 / 1180.14 2 2
3 3 1030.68 1 12.27 2112 26 0.37 / 1180.17 2 2
4 12 1119.68 5 12.05 2228 134 0.50 / 1180.30 2 2
5 12 2007.72 36 10.74 3424 1324 1.83 / 1181.63 2 2
6 7 2004.16 22 10.88 3440 823 2.65 / 1182.45 2 2
7 13 1792.48 42 12.12 3151 1604 4.25 / 1184.05 2 2
8 13 587.24 42 13.37 1471 826 5.08 / 1184.88 2 2
9 8 0.20 170 13.85 616 1450 6.53 / 1186.33 2 9
Average= 5.90 (KJ/cycle)

Cycle 199 GMT 4/11/2020 9: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 29 13.93 770 311 0.31 / 1175.11 2 2
2 10 1000.12 4 13.10 2061 108 0.42 / 1175.22 2 2
3 12 1097.72 36 9.99 2083 749 1.17 / 1175.97 2 2
4 7 1103.92 22 11.76 2151 557 1.72 / 1176.53 2 2
5 13 1010.20 42 12.83 2034 1096 2.82 / 1177.62 2 2
6 13 543.84 42 13.40 1393 784 3.60 / 1178.41 2 3
7 8 0.04 170 13.87 591 1394 5.00 / 1179.80 2 5
Average= 5.90 (KJ/cycle)

Cycle 198 GMT 25/10/2020 17:22: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 429.52 -8 0.00 0 0 0.00 / 1169.48 2 2
2 3 779.92 -3 0.00 0 0 0.00 / 1169.48 2 2
3 7 1432.88 22 12.96 2686 766 0.77 / 1170.24 2 2
4 13 1463.16 42 12.51 2687 1412 2.18 / 1171.66 2 2
5 13 1259.64 42 12.73 2370 1267 3.44 / 1172.92 2 2
6 13 112.92 42 13.91 779 455 3.90 / 1173.38 2 2
7 8 0.08 170 13.91 602 1424 5.32 / 1174.80 2 8
Average= 5.90 (KJ/cycle)

Cycle 197 GMT 25/10/2020 9:38:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 436.92 -8 0.00 0 0 0.00 / 1164.06 2 2
2 3 809.28 -3 0.00 0 0 0.00 / 1164.06 2 2
3 7 1467.88 23 12.89 2702 801 0.80 / 1164.86 2 2
4 13 1499.52 42 12.47 2718 1424 2.22 / 1166.29 2 2
5 13 1288.16 42 12.68 2427 1293 3.52 / 1167.58 2 2
6 13 126.08 42 13.88 807 470 3.99 / 1168.05 2 2
7 8 0.20 170 13.90 604 1427 5.41 / 1169.48 2 6
Average= 5.91 (KJ/cycle)

Cycle 196 GMT 25/10/2020 1:48:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 32 13.88 770 342 0.34 / 1158.06 2 3
2 12 1126.68 5 11.91 2200 131 0.47 / 1158.20 2 2
3 12 2001.52 36 10.62 3411 1304 1.78 / 1159.50 2 2
4 7 1996.76 22 10.87 3405 814 2.59 / 1160.31 2 2
5 13 1562.88 42 12.33 2826 1463 4.05 / 1161.78 2 2
6 13 606.40 42 13.32 1508 844 4.90 / 1162.62 2 2
7 8 0.24 170 13.84 613 1442 6.34 / 1164.06 2 7
Average= 5.91 (KJ/cycle)

Cycle 195 GMT 24/10/2020 1:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 35 13.90 789 384 0.38 / 1154.11 2 3
2 3 912.68 -1 13.90 789 0 0.00 / 1154.11 2 3
3 3 963.00 -1 13.90 789 0 0.00 / 1154.11 2 3
4 12 1055.68 5 10.31 2025 104 0.49 / 1154.21 2 2
5 12 1097.72 36 10.97 2129 841 1.33 / 1155.05 2 2
6 7 1093.48 22 11.76 2170 561 1.89 / 1155.61 2 2
7 13 422.04 42 13.50 1217 690 2.58 / 1156.30 2 3
8 8 0.16 170 13.83 604 1420 4.00 / 1157.72 2 10
Average= 5.91 (KJ/cycle)

Cycle 194 GMT 14/10/2020 9:30: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 441.88 -8 0.00 0 0 0.00 / 1148.57 2 2
2 3 793.08 -3 0.00 0 0 0.00 / 1148.57 2 2
3 7 1444.48 22 12.99 2647 756 0.76 / 1149.33 2 2
4 13 1487.48 42 12.53 2657 1398 2.15 / 1150.73 2 2
5 13 1061.04 42 12.91 2101 1139 3.29 / 1151.87 2 3
6 13 75.68 42 13.95 719 421 3.72 / 1152.29 2 2
7 8 0.00 170 13.90 607 1434 5.15 / 1153.72 2 7
Average= 5.92 (KJ/cycle)

Cycle 193 GMT 14/10/2020 1:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 438.80 -8 0.00 0 0 0.00 / 1142.82 2 2
2 3 793.72 -3 0.00 0 0 0.00 / 1142.82 2 2
3 7 1454.20 22 12.91 2686 763 0.76 / 1143.58 2 2
4 13 1511.36 42 12.44 2776 1450 2.21 / 1145.03 2 2
5 13 1299.16 42 12.67 2432 1294 3.51 / 1146.33 2 2
6 13 138.48 42 13.86 819 477 3.98 / 1146.81 2 3
7 13 1.84 42 14.04 631 372 4.36 / 1147.18 2 2
8 8 0.04 170 13.91 590 1395 5.75 / 1148.57 2 19
Average= 5.92 (KJ/cycle)

Cycle 192 GMT 13/10/2020 17:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 34 13.91 758 358 0.36 / 1136.78 2 3
2 3 932.60 -1 13.91 758 0 0.00 / 1136.78 2 3
3 12 1137.16 5 11.86 2237 133 0.49 / 1136.92 2 2
4 12 2001.64 36 10.48 3430 1294 1.79 / 1138.21 2 2
5 7 1997.24 22 10.86 3426 819 2.60 / 1139.03 2 2
6 13 1589.68 42 12.28 2915 1503 4.11 / 1140.53 2 2
7 13 627.72 42 13.29 1543 861 4.97 / 1141.39 2 3
8 8 0.00 170 13.86 606 1428 6.40 / 1142.82 2 5
Average= 5.92 (KJ/cycle)

Cycle 191 GMT 12/10/2020 14:22: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 25 13.92 795 277 0.28 / 1131.62 2 3
2 10 1040.52 6 13.17 2135 169 0.45 / 1131.79 2 2
3 3 1065.04 3 12.68 2199 84 0.53 / 1131.88 2 2
4 3 1016.68 1 11.94 2069 25 0.55 / 1131.90 2 2
5 12 1134.80 36 9.74 2108 739 1.29 / 1132.64 2 2
6 7 1141.52 22 11.74 2223 574 1.87 / 1133.21 2 2
7 13 1046.80 42 12.77 2102 1127 2.99 / 1134.34 2 2
8 13 373.80 42 13.55 1164 662 3.66 / 1135.00 2 3
9 8 0.08 170 13.85 603 1420 5.08 / 1136.42 2 6
Average= 5.92 (KJ/cycle)

Cycle 190 GMT 2/10/2020 19:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 4 14.05 775 44 0.04 / 1126.34 2 3
2 3 424.72 -8 14.05 775 0 0.00 / 1126.34 2 3
3 3 1233.88 9 13.03 2405 282 0.33 / 1126.62 2 2
4 7 1637.16 22 12.63 2929 814 1.14 / 1127.44 2 2
5 13 1514.56 42 12.35 2807 1456 2.60 / 1128.89 2 2
6 13 851.32 42 13.07 1840 1010 3.61 / 1129.90 2 2
7 8 0.12 170 13.86 613 1444 5.05 / 1131.35 2 6
Average= 5.92 (KJ/cycle)

Cycle 189 GMT 2/10/2020 10:30: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 33 13.87 782 358 0.36 / 1122.10 2 2
2 3 302.52 -10 13.87 782 0 0.00 / 1122.10 2 2
3 3 957.48 -1 13.87 782 0 0.00 / 1122.10 2 2
4 7 1356.80 22 12.83 2592 732 1.09 / 1122.83 2 2
5 13 1214.04 42 12.66 2362 1256 2.35 / 1124.08 2 2
6 13 510.96 42 13.41 1373 773 3.12 / 1124.86 2 2
7 8 0.24 170 13.83 613 1441 4.56 / 1126.30 2 9
Average= 5.93 (KJ/cycle)

Cycle 188 GMT 2/10/2020 1:51:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 26 13.86 782 282 0.28 / 1115.51 2 3
2 10 1034.00 7 13.02 2130 194 0.48 / 1115.70 2 2
3 3 1027.88 1 12.10 2117 26 0.50 / 1115.73 2 2
4 12 1137.40 5 11.97 2246 134 0.64 / 1115.86 2 2
5 12 2001.24 36 10.75 3423 1325 1.96 / 1117.18 2 2
6 7 1996.52 22 10.88 3455 827 2.79 / 1118.01 2 2
7 13 1551.76 42 12.28 2856 1473 4.26 / 1119.48 2 2
8 13 593.64 42 13.31 1497 837 5.10 / 1120.32 2 3
9 8 0.28 170 13.84 602 1416 6.51 / 1121.74 2 11
Average= 5.94 (KJ/cycle)

Cycle 187 GMT 30/ 9/2020 22:38:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 33 13.87 776 355 0.36 / 1108.55 2 3
2 12 1123.00 13 9.04 2063 242 0.60 / 1108.79 2 2
3 12 2002.04 50 5.89 3236 953 1.55 / 1109.74 2 2
4 12 2002.36 36 8.53 3335 1024 2.57 / 1110.77 2 2
5 7 1995.96 22 10.06 3401 753 3.33 / 1111.52 2 2
6 13 1549.96 42 12.07 2867 1453 4.78 / 1112.97 2 2
7 13 574.92 42 13.29 1461 816 5.60 / 1113.79 2 2
8 8 -0.04 170 13.82 611 1435 7.03 / 1115.22 2 6
Average= 5.93 (KJ/cycle)

Cycle 186 GMT 20/ 9/2020 22:29: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 33 13.89 771 353 0.35 / 1101.37 2 3
2 12 1112.08 13 9.09 2069 244 0.60 / 1101.61 2 2
3 12 2005.76 50 6.07 3258 989 1.59 / 1102.60 2 2
4 12 2005.84 36 8.75 3325 1047 2.63 / 1103.65 2 2
5 7 1999.04 22 10.13 3389 755 3.39 / 1104.40 2 2
6 13 1777.48 42 11.76 3163 1562 4.95 / 1105.96 2 2
7 13 539.16 42 13.32 1427 798 5.75 / 1106.76 2 2
8 8 0.12 170 13.86 607 1430 7.18 / 1108.19 2 7
Average= 5.93 (KJ/cycle)

Cycle 185 GMT 10/ 9/2020 21:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 32 13.91 764 340 0.34 / 1094.18 2 3
2 3 1019.00 1 12.21 2101 26 0.37 / 1094.21 2 2
3 12 1129.12 13 9.01 2100 246 0.61 / 1094.46 2 2
4 12 2003.52 50 6.23 3239 1009 1.62 / 1095.46 2 2
5 12 2003.56 36 8.92 3323 1067 2.69 / 1096.53 2 2
6 7 1996.56 22 10.14 3406 760 3.45 / 1097.29 2 2
7 13 1563.32 42 12.12 2876 1464 4.91 / 1098.76 2 2
8 13 600.12 42 13.27 1491 831 5.74 / 1099.59 2 2
9 8 0.00 170 13.86 605 1426 7.17 / 1101.01 2 6
Average= 5.92 (KJ/cycle)

Cycle 184 GMT 31/ 8/2020 21: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 34 13.86 781 368 0.37 / 1087.09 2 2
2 3 958.12 -1 13.86 781 0 0.00 / 1087.09 2 2
3 3 1031.80 1 12.28 2066 25 0.39 / 1087.11 2 2
4 12 1144.84 13 8.92 2088 242 0.64 / 1087.35 2 2
5 12 2003.48 50 6.25 3241 1013 1.65 / 1088.37 2 2
6 12 2003.84 34 8.96 3318 1011 2.66 / 1089.38 2 2
7 7 1997.60 22 10.18 3398 761 3.42 / 1090.14 2 2
8 13 1558.88 42 12.11 2868 1459 4.88 / 1091.60 2 2
9 13 589.04 42 13.29 1476 824 5.70 / 1092.42 2 2
10 8 -0.08 170 13.86 604 1423 7.13 / 1093.84 2 8
Average= 5.91 (KJ/cycle)

Cycle 183 GMT 21/ 8/2020 20:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 31 13.89 771 332 0.33 / 1079.93 2 3
2 3 1059.72 2 12.64 2191 55 0.39 / 1079.98 2 2
3 12 1127.08 13 8.94 2084 242 0.63 / 1080.23 2 2
4 12 2002.24 50 6.26 3262 1021 1.65 / 1081.25 2 2
5 12 2002.64 34 9.05 3310 1018 2.67 / 1082.27 2 2
6 7 1996.40 22 10.22 3329 748 3.42 / 1083.01 2 2
7 13 1551.64 42 12.16 2837 1449 4.87 / 1084.46 2 2
8 13 559.76 42 13.31 1449 810 5.68 / 1085.27 2 2
9 8 0.24 170 13.84 614 1445 7.12 / 1086.72 2 7
Average= 5.91 (KJ/cycle)

Cycle 182 GMT 11/ 8/2020 20:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 31 13.88 768 330 0.33 / 1072.86 2 3
2 12 1131.96 13 9.18 2111 252 0.58 / 1073.11 2 2
3 12 2003.48 50 6.38 3241 1034 1.62 / 1074.14 2 2
4 12 2003.72 34 8.90 3328 1007 2.62 / 1075.15 2 2
5 7 1997.28 22 10.26 3373 761 3.38 / 1075.91 2 2
6 13 1540.52 42 12.18 2797 1431 4.82 / 1077.34 2 2
7 13 561.56 42 13.31 1449 810 5.63 / 1078.15 2 2
8 8 0.12 170 13.85 614 1446 7.07 / 1079.60 2 7
Average= 5.90 (KJ/cycle)

Cycle 181 GMT 1/ 8/2020 20: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 33 13.88 751 344 0.34 / 1065.35 2 3
2 3 947.28 -1 13.88 751 0 0.00 / 1065.35 2 3
3 3 1019.72 1 12.00 2119 25 0.37 / 1065.37 2 2
4 12 1140.40 13 8.89 2118 245 0.61 / 1065.62 2 2
5 12 2002.32 50 6.36 3233 1028 1.64 / 1066.65 2 2
6 12 2001.96 34 8.84 3357 1009 2.65 / 1067.66 2 2
7 7 1994.68 22 10.21 3400 764 3.41 / 1068.42 2 2
8 13 1552.28 42 12.09 2892 1468 4.88 / 1069.89 2 2
9 13 564.68 42 13.30 1454 812 5.70 / 1070.70 2 3
10 13 20.80 42 13.94 669 392 6.09 / 1071.09 2 2
11 8 0.04 170 13.81 611 1434 7.52 / 1072.53 2 17
Average= 5.89 (KJ/cycle)

Cycle 180 GMT 22/ 7/2020 19:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 33 13.87 765 350 0.35 / 1058.27 2 3
2 12 1123.48 13 8.98 2106 246 0.60 / 1058.52 2 2
3 12 2002.72 50 6.25 3228 1009 1.60 / 1059.52 2 2
4 12 2002.40 34 8.80 3375 1010 2.61 / 1060.53 2 2
5 7 1995.48 22 10.25 3397 766 3.38 / 1061.30 2 2
6 13 1547.32 42 12.14 2831 1443 4.82 / 1062.74 2 2
7 13 567.92 42 13.29 1463 817 5.64 / 1063.56 2 2
8 8 0.12 170 13.81 615 1444 7.08 / 1065.00 2 3
Average= 5.88 (KJ/cycle)

Cycle 179 GMT 12/ 7/2020 18:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 33 13.90 756 347 0.35 / 1051.13 2 3
2 12 1126.36 13 9.33 2085 253 0.60 / 1051.38 2 2
3 12 2007.64 50 6.33 3269 1035 1.63 / 1052.41 2 2
4 12 2007.60 34 8.86 3353 1010 2.64 / 1053.42 2 2
5 7 2001.04 22 10.21 3401 764 3.41 / 1054.19 2 2
6 13 1568.16 42 12.12 2877 1465 4.87 / 1055.65 2 2
7 13 581.96 42 13.28 1485 828 5.70 / 1056.48 2 2
8 8 0.28 170 13.81 613 1439 7.14 / 1057.92 2 6
Average= 5.88 (KJ/cycle)

Cycle 178 GMT 2/ 7/2020 17:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 33 13.95 739 340 0.34 / 1044.02 2 3
2 12 1119.04 13 9.14 2064 245 0.59 / 1044.27 2 2
3 12 2002.04 50 6.29 3253 1023 1.61 / 1045.29 2 2
4 12 2001.48 34 8.83 3359 1008 2.62 / 1046.30 2 2
5 7 1994.24 22 10.23 3409 767 3.38 / 1047.07 2 2
6 13 1566.36 42 12.09 2910 1478 4.86 / 1048.54 2 2
7 13 583.48 42 13.30 1461 816 5.68 / 1049.36 2 2
8 8 -0.20 170 13.86 602 1418 7.10 / 1050.78 2 5
Average= 5.87 (KJ/cycle)

Cycle 177 GMT 22/ 6/2020 16:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 33 13.92 737 339 0.34 / 1036.90 2 3
2 12 1099.48 13 9.21 2044 245 0.58 / 1037.15 2 2
3 12 2000.40 50 6.36 3220 1024 1.61 / 1038.17 2 2
4 12 1999.84 34 8.82 3329 998 2.61 / 1039.17 2 2
5 7 1992.48 22 10.25 3404 768 3.37 / 1039.94 2 2
6 13 1556.12 42 12.13 2870 1462 4.84 / 1041.40 2 2
7 13 579.08 42 13.29 1476 824 5.66 / 1042.23 2 2
8 8 0.16 170 13.83 620 1458 7.12 / 1043.68 2 9
Average= 5.86 (KJ/cycle)

Cycle 176 GMT 12/ 6/2020 16:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 33 13.94 747 344 0.34 / 1029.82 2 3
2 12 1119.28 13 9.15 2082 248 0.59 / 1030.07 2 2
3 12 2002.64 50 6.45 3242 1046 1.64 / 1031.11 2 2
4 12 2002.52 34 8.84 3343 1005 2.64 / 1032.12 2 2
5 7 1995.76 22 10.26 3411 770 3.41 / 1032.89 2 2
6 13 1563.64 42 12.13 2871 1463 4.87 / 1034.35 2 2
7 13 560.16 42 13.31 1435 802 5.68 / 1035.15 2 3
8 8 -0.20 170 13.87 600 1415 7.09 / 1036.57 2 5
Average= 5.86 (KJ/cycle)

Cycle 175 GMT 2/ 6/2020 15:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 33 13.91 744 342 0.34 / 1022.74 2 3
2 12 1110.76 13 9.13 2086 248 0.59 / 1022.98 2 2
3 12 2000.88 50 6.46 3248 1049 1.64 / 1024.03 2 2
4 12 2000.52 34 8.84 3348 1006 2.64 / 1025.04 2 2
5 7 1993.32 22 10.26 3417 771 3.42 / 1025.81 2 2
6 13 1549.32 42 12.14 2845 1451 4.87 / 1027.26 2 2
7 13 556.04 42 13.33 1409 789 5.66 / 1028.05 2 2
8 8 0.00 170 13.87 604 1424 7.08 / 1029.48 2 10
Average= 5.85 (KJ/cycle)

Cycle 174 GMT 23/ 5/2020 15:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 33 13.94 738 339 0.34 / 1015.97 2 3
2 12 1100.20 13 9.23 2070 248 0.59 / 1016.22 2 2
3 12 1998.08 50 6.71 3223 1081 1.67 / 1017.30 2 2
4 12 1996.76 34 9.15 3336 1038 2.71 / 1018.34 2 2
5 7 1988.44 22 10.35 3354 764 3.47 / 1019.11 2 2
6 13 1314.36 42 12.46 2491 1304 4.77 / 1020.41 2 2
7 13 327.88 42 13.63 1019 583 5.36 / 1020.99 2 3
8 8 0.12 170 13.87 595 1403 6.76 / 1022.40 2 11
Average= 5.84 (KJ/cycle)

Cycle 173 GMT 13/ 5/2020 13:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 33 13.96 746 344 0.34 / 1008.75 2 3
2 12 1121.96 13 9.23 2100 252 0.60 / 1009.00 2 2
3 12 2000.44 50 6.75 3218 1086 1.68 / 1010.09 2 2
4 12 2000.00 34 9.03 3328 1022 2.70 / 1011.11 2 2
5 7 1992.68 22 10.30 3377 765 3.47 / 1011.88 2 2
6 13 1538.64 42 12.19 2805 1436 4.90 / 1013.31 2 2
7 13 310.92 42 13.61 1044 597 5.50 / 1013.91 2 3
8 13 1.52 42 14.02 619 364 5.87 / 1014.27 2 3
9 8 -0.12 170 13.83 579 1361 7.23 / 1015.64 2 14
Average= 5.84 (KJ/cycle)

Cycle 172 GMT 3/ 5/2020 13:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 33 13.99 719 332 0.33 / 1001.76 2 3
2 12 1114.32 13 9.32 2079 252 0.58 / 1002.01 2 2
3 12 2009.80 50 6.42 3269 1049 1.63 / 1003.06 2 2
4 12 2009.36 32 9.15 3367 986 2.62 / 1004.04 2 2
5 7 2002.96 22 10.30 3410 773 3.39 / 1004.82 2 2
6 13 1555.32 32 12.47 2817 1124 4.52 / 1005.94 2 2
7 13 857.76 32 13.19 1813 765 5.28 / 1006.71 2 2
8 13 66.48 32 13.95 710 317 5.60 / 1007.02 2 2
9 8 0.20 170 13.94 584 1384 6.98 / 1008.41 2 10
Average= 5.83 (KJ/cycle)

Cycle 171 GMT 23/ 4/2020 11:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 33 13.99 723 334 0.33 / 994.78 3 3
2 12 1117.40 13 9.28 2068 249 0.58 / 995.03 2 2
3 12 2002.36 50 6.60 3233 1067 1.65 / 996.09 2 2
4 12 2001.48 32 9.06 3339 968 2.62 / 997.06 2 2
5 7 1994.12 22 10.31 3373 765 3.38 / 997.83 2 2
6 13 1550.48 32 12.45 2817 1122 4.51 / 998.95 2 2
7 13 834.12 32 13.17 1805 761 5.27 / 999.71 2 2
8 13 65.04 32 13.95 711 317 5.58 / 1000.03 2 2
9 8 0.16 170 13.93 591 1400 6.98 / 1001.43 2 8
Average= 5.82 (KJ/cycle)

Cycle 170 GMT 13/ 4/2020 10:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 33 14.01 712 329 0.33 / 987.81 2 3
2 12 1115.48 13 8.88 2085 241 0.57 / 988.05 2 2
3 12 2004.60 50 6.31 3210 1013 1.58 / 989.06 2 2
4 12 2004.36 32 8.66 3321 920 2.50 / 989.98 2 2
5 7 1998.12 22 10.22 3381 760 3.26 / 990.74 2 2
6 13 1784.40 32 12.11 3153 1222 4.48 / 991.96 2 2
7 13 832.88 32 13.17 1811 763 5.25 / 992.72 2 2
8 13 76.72 32 13.92 727 324 5.57 / 993.05 2 2
9 8 0.00 170 13.92 589 1394 6.97 / 994.44 2 7
Average= 5.82 (KJ/cycle)

Cycle 169 GMT 3/ 4/2020 9:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 33 14.04 732 339 0.34 / 980.91 2 3
2 12 1115.80 13 9.13 2067 245 0.58 / 981.16 2 2
3 12 2001.44 78 6.51 3214 1632 2.22 / 982.79 2 2
4 7 1996.08 22 10.38 3380 772 2.99 / 983.56 2 2
5 13 1787.28 32 12.16 3178 1237 4.22 / 984.80 2 2
6 13 1068.96 32 12.97 2137 887 5.11 / 985.68 2 2
7 13 164.76 32 13.82 864 382 5.49 / 986.07 2 2
8 8 -0.16 170 13.90 597 1411 6.90 / 987.48 2 7
Average= 5.81 (KJ/cycle)

Cycle 168 GMT 24/ 3/2020 8:12: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 33 13.99 706 326 0.33 / 974.01 3 3
2 12 1102.52 13 8.93 2041 237 0.56 / 974.25 2 2
3 12 2005.72 78 6.32 3233 1594 2.16 / 975.84 2 2
4 7 2001.36 22 10.33 3428 779 2.94 / 976.62 2 2
5 13 1801.20 32 12.12 3209 1245 4.18 / 977.87 2 2
6 13 1110.52 32 12.92 2229 922 5.10 / 978.79 2 3
7 13 171.96 32 13.83 850 376 5.48 / 979.16 2 2
8 8 0.24 170 13.92 595 1408 6.89 / 980.57 2 8
Average= 5.80 (KJ/cycle)

Cycle 167 GMT 14/ 3/2020 6:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 33 14.01 731 338 0.34 / 967.15 2 3
2 12 1121.88 13 8.93 2075 241 0.58 / 967.39 2 2
3 12 2004.56 78 6.53 3213 1637 2.22 / 969.03 2 2
4 7 1999.16 22 10.39 3397 776 2.99 / 969.80 2 2
5 13 1781.32 32 12.18 3163 1233 4.22 / 971.04 2 2
6 13 1046.80 32 12.98 2142 890 5.11 / 971.93 2 3
7 13 147.16 32 13.85 820 363 5.48 / 972.29 2 2
8 8 -0.04 170 13.92 590 1396 6.87 / 973.69 2 8
Average= 5.80 (KJ/cycle)

Cycle 166 GMT 4/ 3/2020 5:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 33 13.96 741 341 0.34 / 960.19 2 3
2 12 1117.20 13 8.86 2069 238 0.58 / 960.43 2 2
3 12 2004.12 78 6.56 3238 1657 2.24 / 962.09 2 2
4 7 2000.28 22 10.42 3401 780 3.02 / 962.87 2 2
5 13 1813.00 32 12.19 3209 1252 4.27 / 964.12 2 2
6 13 1103.68 32 12.95 2216 918 5.19 / 965.04 2 3
7 13 171.28 32 13.82 860 380 5.57 / 965.42 2 3
8 8 0.00 170 13.92 590 1396 6.96 / 966.81 2 8
Average= 5.79 (KJ/cycle)

Cycle 165 GMT 23/ 2/2020 5: 5: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 33 14.03 717 332 0.33 / 953.41 2 3
2 12 1110.32 13 8.84 2051 236 0.57 / 953.64 2 2
3 12 2000.68 72 6.53 3211 1510 2.08 / 955.15 2 2
4 7 1995.84 22 10.42 3379 775 2.85 / 955.93 2 2
5 13 1788.84 32 12.22 3143 1229 4.08 / 957.16 2 2
6 13 1103.64 32 12.94 2218 918 5.00 / 958.07 2 3
7 13 173.64 32 13.82 871 385 5.38 / 958.46 2 2
8 8 0.12 170 13.91 588 1390 6.78 / 959.85 2 8
Average= 5.78 (KJ/cycle)

Cycle 164 GMT 13/ 2/2020 4:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 33 13.99 746 344 0.34 / 946.58 2 3
2 12 1117.64 13 8.98 2079 243 0.59 / 946.82 2 2
3 12 2001.72 72 6.60 3256 1547 2.13 / 948.37 2 2
4 7 1996.92 22 10.43 3423 785 2.92 / 949.15 2 2
5 13 1784.48 32 12.20 3189 1245 4.16 / 950.40 2 2
6 13 1097.56 32 12.96 2195 910 5.08 / 951.31 2 3
7 13 169.60 32 13.83 864 382 5.46 / 951.69 2 2
8 8 0.04 170 13.93 584 1383 6.84 / 953.07 2 7
Average= 5.78 (KJ/cycle)

Cycle 163 GMT 3/ 2/2020 3: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 33 14.00 722 334 0.33 / 939.76 2 3
2 12 1123.76 13 9.02 2070 243 0.58 / 940.01 2 2
3 12 2005.48 72 6.66 3273 1569 2.15 / 941.57 2 2
4 7 2000.72 22 10.51 3419 791 2.94 / 942.37 2 2
5 13 1794.72 32 12.20 3228 1260 4.20 / 943.63 2 2
6 13 1083.80 32 12.99 2175 904 5.10 / 944.53 2 2
7 13 163.44 32 13.85 841 373 5.47 / 944.90 2 2
8 8 0.00 170 13.96 561 1331 6.80 / 946.23 2 7
Average= 5.77 (KJ/cycle)

Cycle 162 GMT 24/ 1/2020 2: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 33 14.01 730 338 0.34 / 932.88 2 3
2 12 1115.76 13 9.23 2088 251 0.59 / 933.13 2 2
3 12 2001.28 72 6.84 3219 1585 2.17 / 934.72 2 2
4 7 1994.88 22 10.54 3419 793 2.97 / 935.51 2 2
5 13 1780.88 32 12.26 3193 1253 4.22 / 936.76 2 2
6 13 1065.00 32 13.02 2142 892 5.11 / 937.66 2 3
7 13 153.52 32 13.84 850 376 5.49 / 938.03 2 2
8 8 0.08 170 13.91 591 1398 6.89 / 939.43 2 7
Average= 5.76 (KJ/cycle)

Cycle 161 GMT 14/ 1/2020 1: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 33 13.98 736 340 0.34 / 926.23 2 3
2 12 1112.80 13 9.11 2087 247 0.59 / 926.48 2 2
3 12 2000.12 60 6.80 3225 1316 1.90 / 927.79 2 2
4 7 1995.68 22 10.52 3418 791 2.69 / 928.58 2 2
5 13 1793.60 32 12.21 3188 1246 3.94 / 929.83 2 2
6 13 1091.00 32 12.97 2210 917 4.86 / 930.75 2 3
7 13 183.32 32 13.80 906 400 5.26 / 931.15 2 2
8 8 0.20 170 13.89 592 1398 6.65 / 932.54 2 11
Average= 5.76 (KJ/cycle)

Cycle 160 GMT 4/ 1/2020 0: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 33 14.04 711 329 0.33 / 919.57 2 3
2 12 1119.52 13 9.12 2095 248 0.58 / 919.82 2 2
3 12 2002.44 60 6.99 3225 1353 1.93 / 921.17 2 2
4 7 1997.80 22 10.53 3433 795 2.73 / 921.97 2 2
5 13 1784.68 32 12.23 3195 1250 3.98 / 923.22 2 2
6 13 1077.04 32 13.00 2174 904 4.88 / 924.12 2 2
7 13 166.40 32 13.82 878 388 5.27 / 924.51 2 2
8 8 -0.08 170 13.91 584 1381 6.65 / 925.89 2 11
Average= 5.75 (KJ/cycle)

Cycle 159 GMT 24/12/2019 23:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 32 13.99 738 330 0.33 / 912.92 2 3
2 12 1129.04 13 8.99 2086 244 0.57 / 913.17 2 2
3 12 2001.72 60 7.18 3196 1377 1.95 / 914.54 2 2
4 7 1996.84 22 10.56 3426 796 2.75 / 915.34 2 2
5 13 1800.80 32 12.27 3185 1251 4.00 / 916.59 2 2
6 13 1083.76 32 13.02 2130 887 4.88 / 917.48 2 3
7 13 164.00 32 13.84 861 381 5.27 / 917.86 2 2
8 8 -0.04 170 13.92 584 1382 6.65 / 919.24 2 5
Average= 5.75 (KJ/cycle)

Cycle 158 GMT 14/12/2019 22:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 32 13.97 741 331 0.33 / 906.22 2 3
2 12 1124.80 13 9.22 2088 250 0.58 / 906.47 2 2
3 12 2000.88 60 7.13 3241 1386 1.97 / 907.86 2 2
4 7 1995.68 22 10.57 3426 797 2.76 / 908.66 2 2
5 13 1777.04 32 12.26 3177 1246 4.01 / 909.90 2 2
6 13 1069.40 32 12.99 2167 901 4.91 / 910.80 2 3
7 13 156.72 32 13.84 865 383 5.29 / 911.19 2 2
8 8 0.08 170 13.89 595 1405 6.70 / 912.59 2 5
Average= 5.74 (KJ/cycle)

Cycle 157 GMT 4/12/2019 21:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 32 13.96 747 334 0.33 / 899.60 2 3
2 12 1118.40 13 9.12 2106 250 0.58 / 899.85 2 2
3 12 2000.00 60 7.18 3217 1386 1.97 / 901.24 2 2
4 7 1994.48 22 10.63 3408 797 2.77 / 902.04 2 2
5 13 1774.72 32 12.30 3147 1239 4.00 / 903.28 2 2
6 13 1065.12 32 13.03 2142 893 4.90 / 904.17 2 2
7 13 161.56 32 13.84 856 379 5.28 / 904.55 2 2
8 8 0.12 170 13.94 567 1344 6.62 / 905.89 2 8
Average= 5.73 (KJ/cycle)

Cycle 156 GMT 24/11/2019 20:41: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 32 13.97 735 329 0.33 / 892.98 2 3
2 12 1122.80 12 9.16 2077 228 0.56 / 893.21 2 2
3 12 2002.52 55 7.36 3263 1321 1.88 / 894.53 2 2
4 7 1998.28 22 10.62 3434 802 2.68 / 895.33 2 2
5 13 1790.16 32 12.26 3207 1258 3.94 / 896.59 2 2
6 13 1087.44 32 12.96 2224 922 4.86 / 897.51 2 2
7 13 173.12 32 13.82 881 390 5.25 / 897.90 2 3
8 8 0.00 170 13.90 580 1371 6.62 / 899.27 2 8
Average= 5.73 (KJ/cycle)

Cycle 155 GMT 14/11/2019 20: 2: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 32 13.95 750 335 0.33 / 886.43 2 3
2 12 1115.36 12 9.15 2076 228 0.56 / 886.66 2 2
3 12 2000.80 55 7.48 3204 1318 1.88 / 887.98 2 2
4 7 1996.40 22 10.71 3386 798 2.68 / 888.78 2 2
5 13 1781.28 32 12.30 3164 1245 3.92 / 890.02 2 2
6 13 1061.24 32 13.03 2119 884 4.81 / 890.90 2 3
7 13 151.60 32 13.88 843 374 5.18 / 891.28 2 3
8 8 0.40 170 13.91 580 1372 6.55 / 892.65 2 7
Average= 5.72 (KJ/cycle)

Cycle 154 GMT 4/11/2019 19:42:58

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 32 13.97 746 333 0.33 / 879.61 2 3
2 12 1113.04 12 9.13 2055 225 0.56 / 879.83 2 2
3 12 2002.12 55 7.44 3226 1320 1.88 / 881.15 2 2
4 7 1998.16 22 10.68 3422 804 2.68 / 881.96 2 2
5 13 1784.76 32 12.30 3174 1249 3.93 / 883.21 2 2
6 13 1066.80 32 13.02 2121 884 4.82 / 884.09 2 2
7 13 159.44 32 13.87 838 372 5.19 / 884.46 2 2
8 13 13.16 32 14.07 639 288 5.48 / 884.75 2 2
9 8 -0.32 170 13.91 569 1346 6.82 / 886.10 2 19
Average= 5.72 (KJ/cycle)

Cycle 153 GMT 25/10/2019 19:18:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 32 14.02 727 326 0.33 / 873.10 2 3
2 12 1116.24 11 9.05 2044 203 0.53 / 873.30 2 2
3 12 2001.08 53 7.65 3208 1301 1.83 / 874.60 2 2
4 7 1998.04 22 10.72 3381 797 2.63 / 875.40 2 2
5 13 1795.40 32 12.30 3174 1249 3.88 / 876.65 2 2
6 13 1078.68 32 13.01 2149 895 4.77 / 877.54 2 3
7 13 173.60 32 13.86 855 379 5.15 / 877.92 2 2
8 8 0.08 170 13.94 572 1356 6.51 / 879.28 2 8
Average= 5.71 (KJ/cycle)

Cycle 152 GMT 15/10/2019 19: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 32 13.98 730 327 0.33 / 866.58 2 3
2 12 1114.76 11 9.35 2054 211 0.54 / 866.79 2 2
3 12 2003.04 53 7.90 3216 1347 1.88 / 868.14 2 2
4 7 1999.04 22 10.72 3410 804 2.69 / 868.94 2 2
5 13 1778.00 32 12.33 3137 1238 3.93 / 870.18 2 2
6 13 1048.24 32 13.06 2091 874 4.80 / 871.05 2 3
7 13 144.36 32 13.90 820 365 5.16 / 871.42 2 2
8 8 0.24 170 13.94 571 1353 6.52 / 872.77 2 13
Average= 5.70 (KJ/cycle)

Cycle 151 GMT 5/10/2019 18:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 32 13.99 734 329 0.33 / 860.20 2 3
2 12 1099.04 11 9.68 2045 218 0.55 / 860.42 2 2
3 12 2001.36 53 8.22 3255 1418 1.96 / 861.84 2 2
4 7 1997.48 22 10.78 3400 806 2.77 / 862.64 2 2
5 13 1572.60 32 12.57 2869 1154 3.92 / 863.80 2 2
6 13 869.92 32 13.21 1826 772 4.70 / 864.57 2 2
7 13 84.04 32 13.98 735 329 5.03 / 864.90 2 3
8 8 -0.12 170 13.94 571 1353 6.38 / 866.25 2 9
Average= 5.70 (KJ/cycle)

Cycle 150 GMT 25/ 9/2019 17:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 32 13.99 733 328 0.33 / 854.17 2 3
2 12 1138.68 6 7.70 1988 92 0.42 / 854.26 2 2
3 12 2006.36 35 7.99 3191 892 1.31 / 855.16 2 2
4 7 2006.08 22 10.99 3366 814 2.13 / 855.97 2 2
5 13 1820.12 22 12.58 3182 881 3.01 / 856.85 2 2
6 13 1410.08 22 12.97 2582 737 3.74 / 857.59 2 2
7 13 773.80 22 13.39 1717 506 4.25 / 858.09 2 2
8 13 169.80 22 13.92 850 260 4.51 / 858.35 2 2
9 13 3.40 22 14.12 603 187 4.70 / 858.54 2 2
10 8 0.04 170 13.94 562 1332 6.03 / 859.87 2 9
Average= 5.69 (KJ/cycle)

Cycle 149 GMT 15/ 9/2019 17:30: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 32 13.98 716 320 0.32 / 848.18 2 2
2 3 964.88 -1 13.98 716 0 0.00 / 848.18 2 2
3 3 1033.40 1 12.81 2139 27 0.35 / 848.20 2 2
4 12 1150.48 6 7.39 2038 90 0.44 / 848.29 2 2
5 12 2002.16 35 7.85 3214 883 1.32 / 849.18 2 2
6 7 2001.60 22 10.96 3358 810 2.13 / 849.99 2 2
7 13 1815.96 22 12.54 3200 883 3.01 / 850.87 2 2
8 13 1603.76 22 12.79 2881 811 3.82 / 851.68 2 2
9 13 911.12 22 13.32 1887 553 4.38 / 852.23 2 2
10 13 221.28 22 13.87 915 279 4.66 / 852.51 2 2
11 8 0.48 170 13.95 561 1330 5.99 / 853.84 2 6
Average= 5.69 (KJ/cycle)

Cycle 148 GMT 5/ 9/2019 17:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 32 13.96 747 334 0.33 / 842.07 2 2
2 12 1126.40 6 7.55 2032 92 0.43 / 842.16 2 2
3 12 2001.80 35 8.11 3200 908 1.33 / 843.07 2 2
4 7 2001.04 22 10.97 3391 818 2.15 / 843.89 2 2
5 13 1809.08 22 12.58 3183 881 3.03 / 844.77 2 2
6 13 1386.04 22 12.95 2548 726 3.76 / 845.50 2 2
7 13 941.32 22 13.29 1925 563 4.32 / 846.06 2 2
8 13 264.32 22 13.82 983 299 4.62 / 846.36 2 3
9 13 3.08 22 14.14 589 183 4.80 / 846.54 2 4
10 8 0.36 170 13.96 554 1315 6.12 / 847.86 2 7
Average= 5.69 (KJ/cycle)

Cycle 147 GMT 26/ 8/2019 17:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 32 14.00 726 325 0.33 / 835.94 2 3
2 12 1123.60 6 7.61 2003 91 0.42 / 836.03 2 2
3 12 2008.52 35 8.06 3204 904 1.32 / 836.93 2 2
4 7 2008.40 22 10.99 3374 816 2.14 / 837.75 2 2
5 13 1828.72 22 12.55 3181 878 3.01 / 838.62 2 2
6 13 1403.56 22 12.94 2598 740 3.75 / 839.36 2 2
7 13 949.08 22 13.28 1915 559 4.31 / 839.92 2 2
8 13 254.16 22 13.83 977 297 4.61 / 840.22 2 3
9 13 8.40 22 14.11 616 191 4.80 / 840.41 2 2
10 8 0.00 170 13.95 559 1326 6.13 / 841.74 2 9
Average= 5.69 (KJ/cycle)

Cycle 146 GMT 16/ 8/2019 16:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 33 13.99 727 336 0.34 / 829.70 2 3
2 3 959.88 -1 13.99 727 0 0.00 / 829.70 2 3
3 3 1029.96 1 12.70 2123 27 0.36 / 829.73 2 2
4 12 1155.68 6 7.62 1977 90 0.45 / 829.82 2 2
5 12 2007.96 35 8.16 3221 920 1.37 / 830.74 2 2
6 7 2007.68 22 10.98 3397 821 2.19 / 831.56 2 2
7 13 1839.80 22 12.56 3229 892 3.09 / 832.45 2 2
8 13 1418.48 22 12.90 2663 756 3.84 / 833.21 2 2
9 13 974.88 22 13.26 1987 580 4.42 / 833.79 2 2
10 13 274.36 22 13.82 991 301 4.72 / 834.09 2 2
11 13 20.60 22 14.13 620 193 4.92 / 834.28 2 2
12 8 0.04 170 13.98 559 1329 6.24 / 835.61 2 9
Average= 5.68 (KJ/cycle)

Cycle 145 GMT 6/ 8/2019 16:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 33 13.99 719 332 0.33 / 823.54 2 3
2 12 1137.44 6 7.62 2050 94 0.43 / 823.63 2 2
3 12 2001.20 35 8.16 3215 918 1.34 / 824.55 2 2
4 7 2000.56 22 10.98 3375 815 2.16 / 825.36 2 2
5 13 1825.44 22 12.54 3191 880 3.04 / 826.24 2 2
6 13 1388.96 22 12.92 2612 742 3.78 / 826.99 2 2
7 13 947.24 22 13.26 1982 578 4.36 / 827.56 2 2
8 13 236.32 22 13.87 929 283 4.64 / 827.85 2 3
9 13 4.36 22 14.13 616 191 4.84 / 828.04 2 4
10 8 -0.12 170 13.96 559 1327 6.16 / 829.37 2 5
Average= 5.68 (KJ/cycle)

Cycle 144 GMT 27/ 7/2019 16:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 31 14.01 714 310 0.31 / 817.49 2 3
2 3 1030.36 1 12.76 2218 28 0.34 / 817.52 2 2
3 12 1140.36 6 7.87 2037 96 0.43 / 817.61 2 2
4 12 2001.40 35 8.57 3252 975 1.41 / 818.59 2 2
5 7 2000.04 22 10.94 3433 826 2.24 / 819.42 2 2
6 13 1817.16 22 12.55 3235 893 3.13 / 820.31 2 2
7 13 1393.04 22 12.94 2575 733 3.86 / 821.04 2 2
8 13 941.28 22 13.33 1874 550 4.41 / 821.59 2 3
9 13 222.52 22 13.87 927 283 4.69 / 821.87 2 3
10 8 0.08 170 13.97 560 1330 6.02 / 823.20 2 9
Average= 5.68 (KJ/cycle)

Cycle 143 GMT 17/ 7/2019 16: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 33 14.02 708 328 0.33 / 811.50 2 3
2 3 940.68 -1 14.02 708 0 0.00 / 811.50 2 3
3 12 1140.48 6 8.28 2041 101 0.43 / 811.60 2 2
4 12 2002.00 35 8.71 3262 994 1.42 / 812.60 2 2
5 7 2000.16 22 10.91 3478 835 2.26 / 813.43 2 2
6 13 1809.32 22 12.53 3197 881 3.14 / 814.31 2 2
7 13 1371.48 22 12.95 2521 718 3.86 / 815.03 2 2
8 13 921.20 22 13.30 1878 550 4.41 / 815.58 2 2
9 13 202.08 22 13.89 898 274 4.68 / 815.86 2 2
10 8 0.16 170 13.98 557 1324 6.01 / 817.18 2 10
Average= 5.67 (KJ/cycle)

Cycle 142 GMT 7/ 7/2019 16: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 33 14.03 708 328 0.33 / 805.36 2 3
2 12 1123.48 6 7.94 2034 97 0.42 / 805.45 2 2
3 12 2002.08 35 8.62 3247 980 1.40 / 806.43 2 2
4 7 2001.16 22 10.96 3414 823 2.23 / 807.26 2 2
5 13 1813.56 22 12.54 3194 881 3.11 / 808.14 2 2
6 13 1377.56 22 12.92 2574 732 3.84 / 808.87 2 2
7 13 735.88 22 13.44 1642 486 4.33 / 809.35 2 2
8 13 265.16 22 13.83 995 303 4.63 / 809.66 2 3
9 13 23.04 22 14.12 628 195 4.82 / 809.85 2 3
10 8 0.16 170 13.97 557 1323 6.15 / 811.17 2 11
Average= 5.67 (KJ/cycle)

Cycle 141 GMT 27/ 6/2019 15:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 32 14.05 725 326 0.33 / 799.36 2 3
2 12 1133.12 6 8.69 2063 108 0.43 / 799.46 2 2
3 12 2000.76 35 9.00 3228 1017 1.45 / 800.48 2 2
4 7 1998.48 22 10.92 3439 826 2.28 / 801.31 2 2
5 13 1790.80 22 12.51 3182 876 3.15 / 802.18 2 2
6 13 1359.44 22 12.91 2563 728 3.88 / 802.91 2 2
7 13 886.20 22 13.31 1849 541 4.42 / 803.45 2 2
8 13 158.24 22 13.95 807 248 4.67 / 803.70 2 2
9 8 0.08 170 13.98 559 1329 6.00 / 805.03 2 7
Average= 5.67 (KJ/cycle)

Cycle 140 GMT 17/ 6/2019 15:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 32 14.02 741 332 0.33 / 793.30 2 3
2 12 1134.12 6 8.55 2032 104 0.44 / 793.40 2 2
3 12 2003.28 35 8.98 3266 1027 1.46 / 794.43 2 2
4 7 2000.80 22 10.94 3442 828 2.29 / 795.26 2 2
5 13 1800.24 22 12.52 3198 881 3.17 / 796.14 2 2
6 13 1364.48 22 12.92 2556 727 3.90 / 796.87 2 2
7 13 716.00 22 13.42 1640 484 4.38 / 797.35 2 2
8 13 128.32 22 13.96 814 250 4.63 / 797.60 2 2
9 8 0.12 170 13.92 604 1429 6.06 / 799.03 2 10
Average= 5.67 (KJ/cycle)

Cycle 139 GMT 7/ 6/2019 15:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 32 13.96 774 346 0.35 / 787.16 2 3
2 12 1135.76 6 9.09 2079 113 0.46 / 787.27 2 2
3 12 2003.40 35 9.24 3299 1067 1.53 / 788.34 2 2
4 7 2001.80 22 10.96 3448 831 2.36 / 789.17 2 2
5 13 1803.84 22 12.51 3184 876 3.23 / 790.04 2 2
6 13 1359.24 22 12.92 2523 717 3.95 / 790.76 2 2
7 13 889.48 22 13.30 1857 543 4.49 / 791.30 2 3
8 13 165.64 22 13.90 873 267 4.76 / 791.57 2 2
9 8 -0.32 170 13.93 590 1397 6.16 / 792.97 2 10
Average= 5.66 (KJ/cycle)

Cycle 138 GMT 28/ 5/2019 15:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 32 14.07 730 329 0.33 / 781.04 2 3
2 12 1134.64 6 9.45 2067 117 0.45 / 781.15 2 2
3 12 2000.44 35 9.40 3265 1074 1.52 / 782.23 2 2
4 7 1998.00 22 10.98 3406 823 2.34 / 783.05 2 2
5 13 1788.24 22 12.51 3189 878 3.22 / 783.93 2 2
6 13 1360.92 22 12.92 2558 727 3.95 / 784.65 2 2
7 13 689.88 22 13.44 1624 480 4.43 / 785.14 2 2
8 13 113.36 22 13.96 801 246 4.67 / 785.38 2 2
9 8 0.24 170 13.91 604 1428 6.10 / 786.81 2 6
Average= 5.66 (KJ/cycle)

Cycle 137 GMT 18/ 5/2019 15: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 32 14.01 751 337 0.34 / 774.78 2 3
2 12 1126.60 6 9.53 2113 121 0.46 / 774.90 2 2
3 12 2006.92 35 9.49 3294 1094 1.55 / 776.00 2 2
4 7 2004.76 22 10.93 3462 832 2.38 / 776.83 2 2
5 13 1805.40 22 12.50 3191 878 3.26 / 777.71 2 2
6 13 1347.92 22 12.96 2475 706 3.97 / 778.41 2 2
7 13 682.24 22 13.47 1550 459 4.43 / 778.87 2 2
8 13 99.48 22 13.96 779 239 4.67 / 779.11 2 2
9 13 3.52 22 14.10 647 201 4.87 / 779.31 2 2
10 8 -0.08 170 13.90 590 1394 6.26 / 780.71 2 10
Average= 5.66 (KJ/cycle)

Cycle 136 GMT 8/ 5/2019 14:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 32 14.06 746 336 0.34 / 768.69 3 3
2 12 1126.28 6 9.84 2125 125 0.46 / 768.82 2 2
3 12 2000.24 35 9.61 3283 1104 1.57 / 769.92 2 2
4 7 1997.44 22 10.99 3411 825 2.39 / 770.74 2 2
5 13 1777.88 22 12.51 3184 876 3.27 / 771.62 2 2
6 13 1328.00 22 12.95 2498 712 3.98 / 772.33 2 2
7 13 660.48 22 13.47 1551 460 4.44 / 772.79 2 2
8 13 89.00 22 13.98 771 237 4.67 / 773.03 2 3
9 8 -0.08 170 13.92 599 1417 6.09 / 774.45 2 10
Average= 5.65 (KJ/cycle)

Cycle 135 GMT 28/ 4/2019 14:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 32 14.08 719 324 0.32 / 762.60 3 3
2 12 1129.68 6 10.54 2101 133 0.46 / 762.74 2 2
3 12 2001.28 35 9.75 3291 1123 1.58 / 763.86 2 2
4 7 1998.24 22 10.98 3416 825 2.41 / 764.69 2 2
5 13 1595.08 22 12.69 2899 809 3.21 / 765.50 2 2
6 13 1375.64 22 12.87 2599 736 3.95 / 766.23 2 2
7 13 686.20 22 13.42 1614 477 4.43 / 766.71 2 2
8 13 56.96 22 14.02 740 228 4.66 / 766.94 2 2
9 8 0.28 170 13.93 599 1418 6.07 / 768.35 2 6
Average= 5.65 (KJ/cycle)

Cycle 134 GMT 18/ 4/2019 13:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 32 14.03 763 343 0.34 / 756.52 3 3
2 12 1114.64 6 10.54 2149 136 0.48 / 756.66 2 2
3 12 2002.48 35 9.82 3303 1135 1.61 / 757.79 2 2
4 7 1999.56 22 10.96 3426 826 2.44 / 758.62 2 2
5 13 1783.24 22 12.51 3188 877 3.32 / 759.50 2 2
6 13 1315.00 22 12.92 2493 709 4.03 / 760.20 2 2
7 13 618.00 22 13.47 1504 446 4.47 / 760.65 2 2
8 13 37.56 22 14.05 699 216 4.69 / 760.87 2 3
9 8 -0.12 170 13.92 598 1415 6.10 / 762.28 2 8
Average= 5.65 (KJ/cycle)

Cycle 133 GMT 8/ 4/2019 13:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 32 14.00 747 335 0.33 / 750.37 3 3
2 12 1125.52 6 10.66 2152 138 0.47 / 750.51 2 2
3 12 2001.68 35 9.89 3348 1159 1.63 / 751.67 2 2
4 7 1998.24 22 10.98 3436 830 2.46 / 752.50 2 2
5 13 1793.32 22 12.49 3173 872 3.33 / 753.37 2 2
6 13 1329.56 22 12.95 2460 701 4.03 / 754.07 2 2
7 13 644.28 22 13.45 1552 459 4.49 / 754.53 2 2
8 13 76.80 22 14.00 751 231 4.72 / 754.76 2 3
9 8 0.16 170 13.93 597 1414 6.14 / 756.18 2 12
Average= 5.64 (KJ/cycle)

Cycle 132 GMT 29/ 3/2019 13:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 32 14.06 726 327 0.33 / 744.22 2 3
2 12 1132.16 6 10.64 2214 141 0.47 / 744.36 2 2
3 12 2001.40 35 10.00 3362 1177 1.64 / 745.54 2 2
4 7 1997.92 22 10.95 3467 835 2.48 / 746.38 2 2
5 13 1784.36 22 12.47 3222 884 3.36 / 747.26 2 2
6 13 1123.56 22 13.04 2272 652 4.02 / 747.91 2 2
7 13 683.52 22 13.41 1633 482 4.50 / 748.39 2 2
8 13 88.64 22 13.98 771 237 4.73 / 748.63 2 2
9 8 0.08 170 13.91 596 1409 6.14 / 750.04 2 5
Average= 5.64 (KJ/cycle)

Cycle 131 GMT 19/ 3/2019 12:50: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 32 14.05 724 326 0.33 / 737.97 2 3
2 12 1121.08 6 11.14 2145 143 0.47 / 738.12 2 2
3 12 2003.88 35 10.12 3345 1185 1.65 / 739.30 2 2
4 7 2000.20 22 10.96 3421 825 2.48 / 740.13 2 2
5 13 1575.48 22 12.70 2842 794 3.27 / 740.92 2 2
6 13 1141.12 22 13.08 2182 628 3.90 / 741.55 2 2
7 13 677.92 22 13.42 1612 476 4.38 / 742.02 2 2
8 13 82.60 22 13.98 777 239 4.62 / 742.26 2 3
9 13 7.00 22 14.09 663 206 4.82 / 742.47 2 3
10 8 0.00 170 13.89 605 1429 6.25 / 743.90 2 11
Average= 5.64 (KJ/cycle)

Cycle 130 GMT 9/ 3/2019 12:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 32 14.06 744 335 0.33 / 731.87 2 3
2 12 1131.48 6 11.11 2222 148 0.48 / 732.02 2 2
3 12 2004.16 35 10.21 3353 1198 1.68 / 733.22 2 2
4 7 2001.00 22 10.97 3434 829 2.51 / 734.04 2 2
5 13 1788.60 22 12.48 3177 872 3.38 / 734.92 2 2
6 13 1116.92 22 13.05 2219 637 4.02 / 735.55 2 2
7 13 659.00 22 13.43 1569 464 4.48 / 736.02 2 2
8 13 45.92 22 14.03 702 217 4.70 / 736.23 2 2
9 8 0.32 170 13.90 598 1413 6.11 / 737.65 2 8
Average= 5.63 (KJ/cycle)

Cycle 129 GMT 27/ 2/2019 11:39: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 32 14.07 742 334 0.33 / 725.67 2 3
2 12 1137.56 6 11.48 2248 155 0.49 / 725.83 2 2
3 12 2001.92 35 10.21 3394 1213 1.70 / 727.04 2 2
4 7 1997.80 22 10.95 3470 836 2.54 / 727.88 2 2
5 13 1782.64 22 12.47 3211 881 3.42 / 728.76 2 2
6 13 1116.52 22 13.03 2275 652 4.07 / 729.41 2 3
7 13 662.52 22 13.40 1620 478 4.55 / 729.89 2 2
8 13 39.16 22 14.03 698 215 4.76 / 730.10 2 3
9 8 0.08 170 13.90 605 1430 6.19 / 731.53 2 12
Average= 5.63 (KJ/cycle)

Cycle 128 GMT 17/ 2/2019 10:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 32 14.03 739 332 0.33 / 719.50 2 3
2 12 1121.92 6 11.79 2156 153 0.48 / 719.66 2 2
3 12 2000.92 35 10.28 3401 1224 1.71 / 720.88 2 2
4 7 1997.04 22 10.96 3463 835 2.54 / 721.72 2 2
5 13 1782.12 22 12.46 3222 883 3.43 / 722.60 2 2
6 13 1106.32 22 13.04 2218 636 4.06 / 723.23 2 2
7 13 642.80 22 13.43 1568 463 4.53 / 723.70 2 2
8 13 64.92 22 13.99 742 228 4.75 / 723.93 2 2
9 8 0.20 170 13.89 599 1414 6.17 / 725.34 2 10
Average= 5.62 (KJ/cycle)

Cycle 127 GMT 7/ 2/2019 10:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 32 14.05 722 325 0.32 / 713.43 2 3
2 12 1124.44 6 11.82 2167 154 0.48 / 713.58 2 2
3 12 2001.52 35 10.37 3382 1227 1.71 / 714.81 2 2
4 7 1997.56 22 10.96 3424 826 2.53 / 715.63 2 2
5 13 1580.92 22 12.66 2845 792 3.32 / 716.43 2 2
6 13 1152.84 22 13.01 2246 643 3.97 / 717.07 2 2
7 13 684.56 22 13.41 1593 470 4.44 / 717.54 2 2
8 13 50.28 22 14.01 708 218 4.65 / 717.76 2 2
9 8 -0.04 170 13.90 599 1415 6.07 / 719.17 2 7
Average= 5.62 (KJ/cycle)

Cycle 126 GMT 28/ 1/2019 9:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 32 14.01 749 336 0.34 / 707.35 2 3
2 12 1133.12 6 11.80 2196 155 0.49 / 707.51 2 2
3 12 2002.72 35 10.40 3409 1241 1.73 / 708.75 2 2
4 7 1998.40 22 10.95 3429 826 2.56 / 709.57 2 2
5 13 1574.76 22 12.62 2894 803 3.36 / 710.38 2 2
6 13 1123.04 22 13.01 2251 644 4.01 / 711.02 2 2
7 13 647.52 22 13.40 1563 461 4.47 / 711.48 2 2
8 13 34.08 22 14.03 685 211 4.68 / 711.69 2 3
9 8 -0.08 170 13.85 598 1408 6.09 / 713.10 2 7
Average= 5.61 (KJ/cycle)

Cycle 125 GMT 18/ 1/2019 8:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 32 14.00 737 330 0.33 / 701.13 2 3
2 12 1119.40 6 11.92 2159 154 0.48 / 701.28 2 2
3 12 2000.92 35 10.55 3376 1247 1.73 / 702.53 2 2
4 7 1996.24 22 10.95 3430 826 2.56 / 703.35 2 2
5 13 1777.80 22 12.42 3202 875 3.43 / 704.23 2 2
6 13 1300.88 22 12.88 2469 700 4.13 / 704.93 2 2
7 13 594.44 22 13.47 1487 441 4.57 / 705.37 2 3
8 13 40.40 22 14.03 701 216 4.79 / 705.59 2 2
9 8 0.24 170 13.84 608 1431 6.22 / 707.02 2 8
Average= 5.61 (KJ/cycle)

Cycle 124 GMT 8/ 1/2019 8:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 32 13.99 752 337 0.34 / 695.13 2 3
2 12 1124.56 6 11.66 2206 154 0.49 / 695.28 2 2
3 12 2000.92 35 10.61 3392 1260 1.75 / 696.54 2 2
4 7 1997.08 22 10.92 3445 828 2.58 / 697.37 2 2
5 13 1562.48 22 12.63 2864 796 3.37 / 698.17 2 2
6 13 1114.00 22 13.03 2209 633 4.01 / 698.80 2 2
7 13 428.24 22 13.60 1257 376 4.38 / 699.18 2 3
8 13 42.44 22 14.01 709 219 4.60 / 699.40 2 2
9 8 0.00 170 13.85 595 1401 6.00 / 700.80 2 13
Average= 5.61 (KJ/cycle)

Cycle 123 GMT 29/12/2018 7:22: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 32 13.97 747 334 0.33 / 689.08 2 3
2 12 1128.08 6 11.86 2188 156 0.49 / 689.24 2 2
3 12 2000.12 35 10.80 3415 1291 1.78 / 690.53 2 2
4 7 1995.52 22 10.93 3422 823 2.60 / 691.35 2 2
5 13 1566.72 22 12.59 2862 793 3.40 / 692.15 2 2
6 13 1125.92 22 12.98 2220 634 4.03 / 692.78 2 2
7 13 448.96 22 13.55 1286 383 4.41 / 693.16 2 3
8 13 25.28 22 14.01 688 212 4.63 / 693.38 2 2
9 8 0.08 170 13.83 603 1418 6.04 / 694.79 2 6
Average= 5.60 (KJ/cycle)

Cycle 122 GMT 19/12/2018 6: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 32 13.97 761 340 0.34 / 682.93 2 3
2 12 1131.64 6 11.89 2205 157 0.50 / 683.09 2 2
3 12 2000.64 35 10.75 3428 1290 1.79 / 684.38 2 2
4 7 1995.28 59 10.43 3375 2077 3.86 / 686.46 2 2
5 13 970.68 22 13.07 2024 582 4.45 / 687.04 2 2
6 13 293.68 22 13.71 1045 315 4.76 / 687.35 2 3
7 8 0.08 170 13.84 594 1398 6.16 / 688.75 2 7
Average= 5.60 (KJ/cycle)

Cycle 121 GMT 9/12/2018 5: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 32 13.96 773 345 0.35 / 676.55 2 3
2 12 1121.32 6 11.62 2187 152 0.50 / 676.70 2 2
3 12 2001.40 35 10.47 3415 1251 1.75 / 677.95 2 2
4 7 1997.12 59 10.37 3362 2057 3.81 / 680.01 2 2
5 13 1022.60 22 13.05 2113 607 4.41 / 680.61 2 2
6 13 336.92 22 13.68 1119 337 4.75 / 680.95 2 2
7 13 30.84 22 14.06 682 211 4.96 / 681.16 2 2
8 8 0.20 170 13.83 608 1429 6.39 / 682.59 2 4
Average= 5.60 (KJ/cycle)

Cycle 120 GMT 29/11/2018 4:33: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 32 13.99 773 346 0.35 / 670.26 2 3
2 12 1116.84 5 11.76 2167 127 0.47 / 670.39 2 2
3 7 2005.04 58 10.28 3403 2029 2.50 / 672.42 2 2
4 13 1566.20 36 12.31 2853 1264 3.77 / 673.68 2 2
5 13 650.04 36 13.29 1547 740 4.51 / 674.42 2 2
6 13 25.40 36 14.00 678 342 4.85 / 674.77 2 3
7 8 -0.12 170 13.80 612 1436 6.28 / 676.20 2 13
Average= 5.59 (KJ/cycle)

Cycle 119 GMT 19/11/2018 3:55: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 32 13.96 776 347 0.35 / 663.79 2 3
2 12 1119.12 5 11.77 2152 127 0.47 / 663.92 2 2
3 7 2001.16 58 10.30 3394 2028 2.50 / 665.94 2 2
4 13 1781.80 36 12.05 3180 1379 3.88 / 667.32 2 2
5 13 827.40 36 13.10 1792 845 4.73 / 668.17 2 3
6 13 30.96 36 14.00 682 344 5.07 / 668.51 2 2
7 8 -0.08 170 13.82 598 1405 6.47 / 669.92 2 11
Average= 5.58 (KJ/cycle)

Cycle 118 GMT 9/11/2018 3:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 32 13.99 755 338 0.34 / 657.70 2 3
2 12 1132.60 5 11.78 2172 128 0.47 / 657.83 2 2
3 7 2003.88 59 10.31 3409 2074 2.54 / 659.90 2 2
4 13 1581.76 36 12.26 2880 1271 3.81 / 661.18 2 2
5 13 860.92 36 13.08 1824 859 4.67 / 662.03 2 2
6 8 0.24 170 13.83 599 1408 6.08 / 663.44 2 5
Average= 5.58 (KJ/cycle)

Cycle 117 GMT 30/10/2018 3: 9: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 32 13.98 770 344 0.34 / 651.57 2 2
2 12 1127.36 5 11.75 2188 129 0.47 / 651.70 2 2
3 7 2001.96 59 10.37 3403 2082 2.56 / 653.78 2 2
4 13 1574.60 36 12.26 2905 1282 3.84 / 655.07 2 2
5 13 859.36 36 13.06 1847 868 4.71 / 655.94 2 2
6 8 0.28 170 13.81 609 1430 6.14 / 657.36 2 6
Average= 5.57 (KJ/cycle)

Cycle 116 GMT 20/10/2018 2:42: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 32 13.96 775 346 0.35 / 645.33 2 3
2 12 1124.12 5 11.76 2201 129 0.48 / 645.46 2 2
3 7 2005.20 59 10.32 3449 2100 2.58 / 647.56 2 2
4 13 1793.80 36 12.03 3180 1377 3.95 / 648.93 2 2
5 13 818.48 36 13.10 1787 843 4.80 / 649.78 2 3
6 8 -0.04 170 13.81 619 1453 6.25 / 651.23 2 6
Average= 5.57 (KJ/cycle)

Cycle 115 GMT 10/10/2018 2: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 32 13.89 798 355 0.35 / 639.21 2 3
2 12 1124.52 5 11.87 2152 128 0.48 / 639.34 2 2
3 7 2002.64 58 10.35 3422 2054 2.54 / 641.39 2 2
4 13 1568.52 36 12.28 2843 1257 3.79 / 642.65 2 2
5 13 857.56 36 13.05 1857 872 4.67 / 643.52 2 3
6 8 0.28 170 13.80 623 1462 6.13 / 644.98 2 5
Average= 5.56 (KJ/cycle)

Cycle 114 GMT 30/ 9/2018 1:39:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 32 13.98 756 338 0.34 / 633.11 2 3
2 12 1107.64 5 11.81 2151 127 0.47 / 633.23 2 2
3 7 2003.40 58 10.41 3412 2060 2.53 / 635.29 2 2
4 13 1561.32 36 12.29 2836 1255 3.78 / 636.55 2 2
5 13 850.16 36 13.09 1809 852 4.63 / 637.40 2 2
6 8 -0.08 170 13.79 620 1453 6.09 / 638.85 2 4
Average= 5.56 (KJ/cycle)

Cycle 113 GMT 20/ 9/2018 1: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 32 13.93 792 353 0.35 / 626.40 2 3
2 12 1117.68 5 11.80 2159 127 0.48 / 626.53 2 2
3 7 2005.48 58 10.42 3422 2068 2.55 / 628.60 2 2
4 13 1786.20 36 12.02 3194 1382 3.93 / 629.98 2 2
5 13 1033.76 36 12.91 2040 948 4.88 / 630.93 2 2
6 13 103.92 36 13.89 795 398 5.28 / 631.33 2 2
7 8 0.32 170 13.81 614 1441 6.72 / 632.77 2 7
Average= 5.55 (KJ/cycle)

Cycle 112 GMT 10/ 9/2018 0:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 32 13.95 783 350 0.35 / 620.18 2 2
2 12 1120.32 5 11.83 2181 129 0.48 / 620.31 2 2
3 7 2001.44 59 10.41 3397 2086 2.56 / 622.40 2 2
4 13 1778.68 36 12.03 3152 1365 3.93 / 623.76 2 2
5 13 791.72 36 13.11 1759 830 4.76 / 624.59 2 2
6 8 -0.24 170 13.78 622 1457 6.22 / 626.05 2 6
Average= 5.54 (KJ/cycle)

Cycle 111 GMT 31/ 8/2018 0:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 32 13.93 791 353 0.35 / 614.07 2 3
2 12 1131.48 5 11.83 2226 132 0.48 / 614.20 2 2
3 7 2001.92 59 10.42 3404 2093 2.58 / 616.29 2 2
4 13 1571.40 36 12.25 2833 1249 3.83 / 617.54 2 2
5 13 856.88 36 13.05 1823 856 4.68 / 618.40 2 2
6 8 0.24 170 13.80 612 1436 6.12 / 619.83 2 7
Average= 5.53 (KJ/cycle)

Cycle 110 GMT 21/ 8/2018 0: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 32 13.94 788 352 0.35 / 608.03 2 3
2 3 968.96 -1 13.94 788 0 0.00 / 608.03 2 3
3 3 1047.68 1 12.18 2205 27 0.38 / 608.06 2 2
4 12 1164.72 5 11.79 2288 135 0.51 / 608.19 2 2
5 7 2000.64 58 10.53 3399 2076 2.59 / 610.27 2 2
6 13 1557.96 36 12.26 2842 1254 3.84 / 611.52 2 2
7 13 626.48 36 13.30 1519 727 4.57 / 612.25 2 2
8 8 0.36 170 13.79 624 1463 6.03 / 613.71 2 6
Average= 5.53 (KJ/cycle)

Cycle 109 GMT 10/ 8/2018 23:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 32 13.96 781 349 0.35 / 601.45 2 3
2 12 1114.84 5 11.88 2185 130 0.48 / 601.58 2 2
3 7 2001.92 59 10.49 3399 2104 2.58 / 603.68 2 2
4 13 1779.84 36 12.02 3172 1373 3.95 / 605.06 2 2
5 13 807.40 36 13.12 1759 831 4.79 / 605.89 2 2
6 13 27.32 36 13.98 700 352 5.14 / 606.24 2 2
7 8 0.12 170 13.78 615 1441 6.58 / 607.68 2 8
Average= 5.52 (KJ/cycle)

Cycle 108 GMT 31/ 7/2018 23:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 32 13.95 805 359 0.36 / 594.83 2 3
2 12 1131.96 5 11.94 2220 133 0.49 / 594.96 2 2
3 7 2004.00 58 10.53 3409 2082 2.57 / 597.05 2 2
4 13 1787.88 36 11.98 3201 1381 3.95 / 598.43 2 2
5 13 814.64 36 13.08 1805 850 4.80 / 599.28 2 2
6 13 60.04 36 13.93 751 377 5.18 / 599.65 2 2
7 8 -0.20 170 13.79 618 1449 6.63 / 601.10 2 12
Average= 5.51 (KJ/cycle)

Cycle 107 GMT 21/ 7/2018 23:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 32 13.94 787 351 0.35 / 588.26 2 3
2 12 1130.16 5 12.00 2205 132 0.48 / 588.39 2 2
3 7 2001.40 59 10.52 3401 2111 2.59 / 590.50 2 2
4 13 1780.84 36 11.99 3184 1374 3.97 / 591.87 2 2
5 13 801.92 36 13.09 1789 843 4.81 / 592.72 2 2
6 13 9.28 36 14.02 662 334 5.15 / 593.05 2 3
7 8 0.12 170 13.74 608 1420 6.57 / 594.47 2 10
Average= 5.50 (KJ/cycle)

Cycle 106 GMT 11/ 7/2018 23: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 32 14.02 753 338 0.34 / 582.04 2 3
2 12 1129.16 5 11.94 2196 131 0.47 / 582.17 2 2
3 7 2002.16 58 10.50 3399 2070 2.54 / 584.24 2 2
4 13 1781.68 36 12.01 3168 1370 3.91 / 585.61 2 2
5 13 814.60 36 13.09 1790 844 4.75 / 586.46 2 2
6 8 0.08 170 13.80 617 1447 6.20 / 587.91 2 5
Average= 5.49 (KJ/cycle)

Cycle 105 GMT 1/ 7/2018 22:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 32 13.98 775 347 0.35 / 575.71 2 3
2 12 1131.44 5 12.00 2192 132 0.48 / 575.84 2 2
3 7 2002.72 59 10.55 3381 2105 2.58 / 577.95 2 2
4 13 1579.36 36 12.25 2848 1256 3.84 / 579.20 2 2
5 13 645.96 36 13.26 1561 745 4.58 / 579.95 2 2
6 13 11.00 36 14.02 663 335 4.92 / 580.28 2 2
7 8 0.08 170 13.75 609 1424 6.34 / 581.71 2 9
Average= 5.49 (KJ/cycle)

Cycle 104 GMT 21/ 6/2018 21:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 32 13.95 788 352 0.35 / 569.65 2 3
2 12 1123.60 5 12.00 2194 132 0.48 / 569.78 2 2
3 7 2000.76 58 10.59 3379 2075 2.56 / 571.85 2 2
4 13 1566.16 36 12.28 2813 1244 3.80 / 573.10 2 2
5 13 810.60 36 13.10 1770 835 4.64 / 573.93 2 2
6 8 -0.08 170 13.80 610 1431 6.07 / 575.36 2 10
Average= 5.48 (KJ/cycle)

Cycle 103 GMT 11/ 6/2018 21:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 32 14.00 768 344 0.34 / 563.07 2 3
2 12 1126.48 5 11.93 2206 132 0.48 / 563.20 2 2
3 7 2001.92 58 10.57 3400 2084 2.56 / 565.29 2 2
4 13 1788.16 36 11.98 3199 1380 3.94 / 566.67 2 2
5 13 817.88 36 13.07 1815 854 4.79 / 567.52 2 2
6 13 58.20 36 13.96 713 358 5.15 / 567.88 2 2
7 8 0.04 170 13.80 603 1415 6.57 / 569.30 2 6
Average= 5.47 (KJ/cycle)

Cycle 102 GMT 1/ 6/2018 21:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 32 13.99 763 342 0.34 / 556.67 2 3
2 12 1108.16 5 11.98 2167 130 0.47 / 556.80 2 2
3 7 2003.36 59 10.57 3396 2118 2.59 / 558.92 2 2
4 13 1561.04 36 12.27 2807 1240 3.83 / 560.16 2 2
5 13 838.88 36 13.05 1828 859 4.69 / 561.02 2 2
6 13 1.24 36 14.05 637 322 5.01 / 561.34 2 3
7 8 -0.04 170 13.69 596 1387 6.40 / 562.73 2 6
Average= 5.46 (KJ/cycle)

Cycle 101 GMT 22/ 5/2018 20:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 32 13.99 766 343 0.34 / 550.29 2 3
2 12 1125.48 5 12.01 2204 132 0.48 / 550.42 2 2
3 7 2003.32 59 10.58 3395 2119 2.59 / 552.54 2 2
4 13 1567.60 36 12.23 2892 1273 3.87 / 553.82 2 2
5 13 636.68 36 13.27 1554 742 4.61 / 554.56 2 2
6 13 29.56 36 13.97 688 346 4.96 / 554.90 2 2
7 8 -0.04 170 13.76 610 1427 6.38 / 556.33 2 7
Average= 5.45 (KJ/cycle)

Cycle 100 GMT 12/ 5/2018 19:54: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 32 13.97 768 343 0.34 / 543.86 2 3
2 12 1132.04 5 12.08 2167 131 0.47 / 543.99 2 2
3 7 2002.52 58 10.61 3371 2074 2.55 / 546.07 2 2
4 13 1573.04 36 12.27 2834 1252 3.80 / 547.32 2 2
5 13 840.60 36 13.08 1814 854 4.65 / 548.17 2 2
6 13 26.12 36 13.99 692 349 5.00 / 548.52 2 2
7 8 0.16 170 13.77 610 1428 6.43 / 549.95 2 8
Average= 5.45 (KJ/cycle)

Cycle 99 GMT 2/ 5/2018 19:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 32 14.04 771 346 0.35 / 537.38 2 3
2 12 1128.32 5 12.05 2196 132 0.48 / 537.51 2 2
3 7 2002.04 59 10.61 3398 2127 2.61 / 539.64 2 2
4 13 1566.92 36 12.29 2815 1245 3.85 / 540.89 2 2
5 13 842.84 36 13.09 1803 850 4.70 / 541.74 2 3
6 13 26.56 36 13.99 690 348 5.05 / 542.08 2 2
7 8 -0.04 170 13.76 613 1434 6.48 / 543.52 2 10
Average= 5.44 (KJ/cycle)

Cycle 98 GMT 22/ 4/2018 19: 7: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 32 14.03 764 343 0.34 / 530.94 2 3
2 12 1127.40 5 12.03 2182 131 0.47 / 531.07 2 2
3 7 2005.08 59 10.63 3392 2127 2.60 / 533.20 2 2
4 13 1556.20 36 12.29 2840 1257 3.86 / 534.45 2 2
5 13 821.48 36 13.11 1786 843 4.70 / 535.30 2 2
6 13 12.24 36 14.04 653 330 5.03 / 535.63 2 3
7 8 -0.04 170 13.75 602 1407 6.44 / 537.04 2 10
Average= 5.42 (KJ/cycle)

Cycle 97 GMT 12/ 4/2018 18:40: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 31 14.03 757 329 0.33 / 524.43 3 3
2 12 1131.40 5 12.16 2215 135 0.46 / 524.56 2 2
3 7 2000.84 59 10.68 3392 2137 2.60 / 526.70 2 2
4 13 1561.32 36 12.29 2840 1257 3.86 / 527.96 2 2
5 13 836.04 36 13.08 1833 863 4.72 / 528.82 2 2
6 13 28.92 36 14.00 688 347 5.07 / 529.17 2 3
7 8 0.12 170 13.78 610 1429 6.50 / 530.60 2 9
Average= 5.41 (KJ/cycle)

Cycle 96 GMT 2/ 4/2018 18:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 31 14.06 766 334 0.33 / 517.92 3 3
2 12 1136.00 5 12.12 2219 134 0.47 / 518.06 2 2
3 7 2002.88 58 10.69 3395 2105 2.57 / 520.16 2 2
4 13 1570.20 36 12.28 2897 1281 3.85 / 521.44 2 2
5 13 833.24 36 13.10 1830 863 4.72 / 522.31 2 2
6 13 27.68 36 13.99 709 357 5.07 / 522.66 2 3
7 8 0.04 170 13.78 613 1436 6.51 / 524.10 2 12
Average= 5.40 (KJ/cycle)

Cycle 95 GMT 23/ 3/2018 17:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 31 14.08 751 328 0.33 / 511.34 2 3
2 12 1132.28 5 12.12 2205 134 0.46 / 511.47 2 2
3 7 2002.32 59 10.70 3406 2150 2.61 / 513.62 2 2
4 13 1561.00 36 12.29 2877 1273 3.88 / 514.90 2 2
5 13 825.88 36 13.10 1828 862 4.75 / 515.76 2 2
6 13 52.48 36 13.96 737 370 5.12 / 516.13 2 3
7 8 -0.12 170 13.77 624 1461 6.58 / 517.59 2 8
Average= 5.39 (KJ/cycle)

Cycle 94 GMT 13/ 3/2018 17:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 31 14.07 778 339 0.34 / 504.86 2 3
2 12 1133.36 5 12.14 2217 135 0.47 / 504.99 2 2
3 7 2003.84 59 10.78 3360 2137 2.61 / 507.13 2 2
4 13 1551.96 36 12.34 2815 1251 3.86 / 508.38 2 2
5 13 811.60 36 13.12 1785 843 4.70 / 509.22 2 2
6 13 27.68 36 14.00 695 350 5.05 / 509.57 2 2
7 8 0.12 170 13.78 615 1441 6.50 / 511.01 2 12
Average= 5.38 (KJ/cycle)

Cycle 93 GMT 3/ 3/2018 17: 9: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 31 14.08 754 329 0.33 / 498.25 2 3
2 12 1135.32 5 12.12 2228 135 0.46 / 498.39 2 2
3 7 2001.96 59 10.75 3397 2155 2.62 / 500.54 2 2
4 13 1576.32 36 12.31 2888 1280 3.90 / 501.82 2 2
5 13 828.96 36 13.12 1829 864 4.76 / 502.68 2 2
6 13 27.80 36 13.98 727 366 5.13 / 503.05 2 3
7 8 -0.04 170 13.76 627 1467 6.59 / 504.52 2 11
Average= 5.37 (KJ/cycle)

Cycle 92 GMT 21/ 2/2018 16:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 31 14.12 739 323 0.32 / 491.74 3 3
2 12 1116.76 5 12.27 2180 134 0.46 / 491.87 2 2
3 7 2003.32 59 10.80 3366 2145 2.60 / 494.02 2 2
4 13 1558.32 36 12.37 2839 1264 3.87 / 495.28 2 2
5 13 818.20 36 13.14 1786 845 4.71 / 496.13 2 2
6 13 24.28 36 14.00 701 353 5.06 / 496.48 2 3
7 8 0.00 170 13.78 615 1441 6.51 / 497.92 2 12
Average= 5.35 (KJ/cycle)

Cycle 91 GMT 11/ 2/2018 16:25: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 31 14.07 764 333 0.33 / 485.21 3 3
2 12 1123.36 5 12.21 2242 137 0.47 / 485.34 2 2
3 7 2003.84 58 10.83 3390 2129 2.60 / 487.47 2 2
4 13 1561.32 36 12.35 2870 1276 3.88 / 488.75 2 2
5 13 829.00 36 13.10 1851 873 4.75 / 489.62 2 3
6 13 25.08 36 14.00 699 352 5.10 / 489.97 2 2
7 8 -0.04 170 13.77 616 1442 6.54 / 491.42 2 15
Average= 5.34 (KJ/cycle)

Cycle 90 GMT 1/ 2/2018 16:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 31 14.08 747 326 0.33 / 478.80 2 3
2 12 1129.68 5 12.21 2262 138 0.46 / 478.94 2 2
3 7 2004.04 58 10.86 3376 2126 2.59 / 481.06 2 2
4 13 1564.44 36 12.38 2870 1279 3.87 / 482.34 2 2
5 13 615.68 36 13.34 1518 729 4.60 / 483.07 2 3
6 13 28.00 36 14.01 703 355 4.95 / 483.42 2 2
7 8 -0.08 170 13.77 619 1449 6.40 / 484.87 2 7
Average= 5.33 (KJ/cycle)

Cycle 89 GMT 22/ 1/2018 15:46: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 31 14.09 750 328 0.33 / 472.46 2 3
2 12 1127.88 5 12.32 2199 135 0.46 / 472.60 2 2
3 7 2001.80 58 10.89 3385 2138 2.60 / 474.73 2 2
4 13 1570.00 36 12.43 2803 1254 3.86 / 475.99 2 2
5 13 623.68 36 13.36 1514 728 4.58 / 476.72 2 2
6 13 30.88 36 14.02 673 340 4.92 / 477.06 2 2
7 8 0.08 170 13.79 604 1416 6.34 / 478.47 2 11
Average= 5.32 (KJ/cycle)

Cycle 88 GMT 12/ 1/2018 15: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 31 14.07 764 333 0.33 / 466.09 2 3
2 12 1129.20 5 12.35 2222 137 0.47 / 466.23 2 2
3 7 2003.16 58 10.94 3407 2162 2.63 / 468.39 2 2
4 13 1542.84 36 12.43 2832 1267 3.90 / 469.66 2 2
5 13 585.40 36 13.40 1478 713 4.61 / 470.37 2 3
6 13 25.44 36 14.03 683 345 4.96 / 470.72 2 2
7 8 -0.08 170 13.79 603 1414 6.37 / 472.13 2 8
Average= 5.30 (KJ/cycle)

Cycle 87 GMT 2/ 1/2018 14:44: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 31 14.11 748 327 0.33 / 459.71 2 3
2 12 1133.24 5 12.31 2229 137 0.46 / 459.84 2 2
3 7 2005.52 58 11.00 3409 2175 2.64 / 462.02 2 2
4 13 1551.76 36 12.45 2851 1278 3.92 / 463.30 2 2
5 13 593.16 36 13.41 1473 711 4.63 / 464.01 2 3
6 13 8.00 36 14.07 652 330 4.96 / 464.34 2 3
7 8 0.44 170 13.73 610 1424 6.38 / 465.76 2 8
Average= 5.29 (KJ/cycle)

Cycle 86 GMT 23/12/2017 14:13: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 31 14.06 770 336 0.34 / 453.59 2 3
2 12 1128.00 3 12.00 2236 80 0.42 / 453.67 2 2
3 7 2003.24 58 11.13 3413 2203 2.62 / 455.88 2 2
4 13 1582.84 37 12.48 2821 1303 3.92 / 457.18 2 2
5 13 623.32 37 13.36 1543 763 4.68 / 457.94 2 3
6 8 -0.24 170 13.82 611 1435 6.12 / 459.38 2 8
Average= 5.28 (KJ/cycle)

Cycle 85 GMT 13/12/2017 14:12: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 31 14.08 780 340 0.34 / 447.27 2 2
2 12 1118.28 3 11.73 2211 78 0.42 / 447.35 2 2
3 7 2002.44 58 11.15 3400 2199 2.62 / 449.55 2 2
4 13 1784.92 37 12.27 3166 1437 4.05 / 450.98 2 2
5 13 771.52 37 13.23 1732 848 4.90 / 451.83 2 2
6 8 0.36 170 13.82 607 1426 6.33 / 453.26 2 7
Average= 5.27 (KJ/cycle)

Cycle 84 GMT 3/12/2017 14:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 31 14.05 780 340 0.34 / 440.55 2 3
2 12 1136.84 3 11.79 2282 81 0.42 / 440.63 2 2
3 7 2004.20 58 11.18 3416 2215 2.64 / 442.85 2 2
4 13 1783.04 37 12.27 3210 1457 4.09 / 444.31 2 2
5 13 772.28 37 13.21 1771 866 4.96 / 445.17 2 2
6 13 4.64 37 14.06 662 344 5.30 / 445.52 2 2
7 8 0.16 170 13.73 606 1414 6.72 / 446.93 2 11
Average= 5.26 (KJ/cycle)

Cycle 83 GMT 23/11/2017 14:34: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 31 14.05 784 341 0.34 / 434.15 2 3
2 12 1124.84 3 11.94 2235 80 0.42 / 434.23 2 2
3 7 2008.16 58 11.13 3405 2198 2.62 / 436.43 2 2
4 13 1792.44 37 12.29 3186 1449 4.07 / 437.88 2 2
5 13 781.80 37 13.21 1771 866 4.93 / 438.74 2 2
6 8 0.16 170 13.81 626 1470 6.40 / 440.21 2 10
Average= 5.24 (KJ/cycle)

Cycle 82 GMT 13/11/2017 14:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 31 14.05 770 335 0.34 / 428.01 2 3
2 12 1121.52 3 11.59 2251 78 0.41 / 428.09 2 2
3 7 2003.96 59 11.08 3422 2237 2.65 / 430.33 2 2
4 13 1566.64 37 12.53 2840 1317 3.97 / 431.65 2 2
5 13 616.12 37 13.42 1508 749 4.72 / 432.39 2 2
6 8 -0.04 170 13.83 602 1415 6.13 / 433.81 2 6
Average= 5.23 (KJ/cycle)

Cycle 81 GMT 3/11/2017 14:30: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 31 14.07 784 342 0.34 / 422.20 2 3
2 7 2008.44 49 10.96 3388 1819 2.16 / 424.02 3 2
3 13 1619.44 38 12.50 2906 1380 3.54 / 425.40 2 2
4 13 711.80 38 13.31 1680 850 4.39 / 426.25 2 3
5 8 0.24 170 13.82 609 1431 5.82 / 427.68 2 5
Average= 5.22 (KJ/cycle)

Cycle 80 GMT 24/10/2017 14:18: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 31 14.07 777 339 0.34 / 416.01 2 2
2 7 2003.12 49 10.96 3401 1826 2.17 / 417.83 2 2
3 13 1621.40 38 12.50 2936 1395 3.56 / 419.23 2 2
4 13 730.80 38 13.30 1701 860 4.42 / 420.09 2 3
5 13 4.00 38 14.07 663 354 4.77 / 420.44 2 3
6 8 0.00 170 13.74 606 1415 6.19 / 421.86 2 9
Average= 5.21 (KJ/cycle)

Cycle 79 GMT 14/10/2017 14:12: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 31 14.08 770 336 0.34 / 410.21 2 2
2 7 2007.96 49 11.05 3365 1822 2.16 / 412.03 2 2
3 13 1636.52 38 12.54 2887 1376 3.53 / 413.41 2 2
4 13 739.56 38 13.32 1704 862 4.40 / 414.27 2 2
5 8 0.16 170 13.85 594 1399 5.79 / 415.67 2 7
Average= 5.20 (KJ/cycle)

Cycle 78 GMT 4/10/2017 14:14: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 31 14.11 757 331 0.33 / 404.31 2 3
2 7 2006.60 49 10.96 3392 1822 2.15 / 406.14 3 2
3 13 1809.96 38 12.32 3225 1510 3.66 / 407.65 2 2
4 13 681.68 38 13.35 1622 823 4.49 / 408.47 2 2
5 8 0.28 170 13.87 595 1403 5.89 / 409.87 2 5
Average= 5.19 (KJ/cycle)

Cycle 77 GMT 24/ 9/2017 14:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 31 14.12 755 330 0.33 / 398.56 2 3
2 7 2002.44 49 11.04 3362 1819 2.15 / 400.38 3 2
3 13 1622.56 38 12.56 2871 1370 3.52 / 401.75 2 2
4 13 738.76 38 13.35 1675 850 4.37 / 402.60 2 2
5 8 -0.04 170 13.91 586 1386 5.75 / 403.98 2 8
Average= 5.18 (KJ/cycle)

Cycle 76 GMT 14/ 9/2017 14:10: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 30 14.17 757 322 0.32 / 392.64 2 3
2 3 1021.44 1 10.98 2138 23 0.35 / 392.66 2 2
3 3 1022.20 1 10.92 2109 23 0.37 / 392.68 2 2
4 7 2003.40 49 11.07 3346 1815 2.18 / 394.50 2 2
5 13 1803.44 38 12.36 3208 1507 3.69 / 396.00 2 2
6 13 684.68 38 13.38 1632 830 4.52 / 396.83 2 2
7 8 0.00 170 13.91 590 1395 5.91 / 398.23 2 6
Average= 5.17 (KJ/cycle)

Cycle 75 GMT 4/ 9/2017 14:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 31 14.15 741 325 0.33 / 386.74 2 3
2 3 942.64 -1 14.15 741 0 0.00 / 386.74 2 3
3 7 2004.84 49 11.00 3344 1802 2.13 / 388.54 2 2
4 13 1810.52 38 12.35 3207 1505 3.63 / 390.05 2 2
5 13 872.08 38 13.25 1832 922 4.55 / 390.97 2 2
6 8 0.32 170 13.94 567 1344 5.90 / 392.31 2 10
Average= 5.16 (KJ/cycle)

Cycle 74 GMT 25/ 8/2017 14:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 30 14.17 747 318 0.32 / 381.02 2 3
2 7 2006.28 49 11.04 3341 1807 2.12 / 382.83 2 2
3 13 1614.36 38 12.60 2862 1370 3.50 / 384.20 2 2
4 13 746.32 38 13.37 1670 848 4.34 / 385.05 2 2
5 8 -0.16 170 13.93 577 1366 5.71 / 386.41 2 5
Average= 5.15 (KJ/cycle)

Cycle 73 GMT 15/ 8/2017 14:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 31 14.20 726 320 0.32 / 375.10 2 3
2 3 949.48 -1 14.20 726 0 0.00 / 375.10 2 3
3 3 1023.16 1 11.72 2197 26 0.35 / 375.13 2 2
4 7 2008.52 49 10.98 3351 1803 2.15 / 376.93 2 2
5 13 1810.88 38 12.40 3164 1491 3.64 / 378.42 2 2
6 13 868.20 38 13.27 1830 923 4.56 / 379.34 2 2
7 8 0.44 170 13.95 574 1361 5.92 / 380.70 2 8
Average= 5.14 (KJ/cycle)

Cycle 72 GMT 5/ 8/2017 14:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 31 14.19 737 324 0.32 / 369.15 2 3
2 7 2003.12 49 10.99 3355 1807 2.13 / 370.96 3 2
3 13 1619.36 38 12.61 2880 1380 3.51 / 372.34 2 2
4 13 715.64 38 13.42 1615 824 4.33 / 373.16 2 2
5 13 17.48 38 14.20 596 322 4.66 / 373.49 2 3
6 8 -0.16 170 13.89 549 1296 5.95 / 374.78 2 9
Average= 5.13 (KJ/cycle)

Cycle 71 GMT 26/ 7/2017 14:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 31 14.20 751 331 0.33 / 363.40 2 3
2 7 2008.68 49 10.97 3340 1795 2.13 / 365.19 3 2
3 13 1810.36 38 12.43 3160 1493 3.62 / 366.69 2 2
4 13 681.76 38 13.45 1577 806 4.42 / 367.49 2 2
5 8 0.16 170 13.96 563 1336 5.76 / 368.83 2 5
Average= 5.12 (KJ/cycle)

Cycle 70 GMT 16/ 7/2017 14:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 31 14.21 731 322 0.32 / 357.49 2 3
2 7 2003.40 49 11.02 3354 1811 2.13 / 359.30 3 2
3 13 1804.72 38 12.44 3157 1492 3.63 / 360.79 2 2
4 13 865.12 38 13.29 1816 917 4.54 / 361.71 2 2
5 8 -0.08 170 13.93 575 1362 5.90 / 363.07 2 7
Average= 5.11 (KJ/cycle)

Cycle 69 GMT 6/ 7/2017 14:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 31 14.22 719 317 0.32 / 351.80 2 3
2 7 2007.20 49 11.04 3349 1812 2.13 / 353.62 2 2
3 13 1618.12 38 12.66 2842 1367 3.50 / 354.98 2 2
4 13 724.88 38 13.44 1616 825 4.32 / 355.81 2 2
5 8 0.16 170 13.96 571 1355 5.68 / 357.16 2 10
Average= 5.10 (KJ/cycle)

Cycle 68 GMT 26/ 6/2017 14:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 31 14.26 696 308 0.31 / 346.14 2 3
2 7 2001.40 49 11.08 3339 1813 2.12 / 347.95 3 2
3 13 1637.36 38 12.64 2858 1373 3.49 / 349.33 2 2
4 13 741.76 38 13.43 1638 836 4.33 / 350.16 2 2
5 8 0.12 170 13.99 557 1325 5.65 / 351.49 2 10
Average= 5.09 (KJ/cycle)

Cycle 67 GMT 16/ 6/2017 14: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 31 14.28 677 300 0.30 / 340.31 2 3
2 7 2004.24 49 11.11 3347 1822 2.12 / 342.14 3 2
3 13 1810.76 38 12.46 3163 1498 3.62 / 343.63 2 2
4 13 853.44 38 13.31 1815 918 4.54 / 344.55 2 2
5 8 0.12 170 14.00 539 1283 5.82 / 345.83 2 7
Average= 5.09 (KJ/cycle)

Cycle 66 GMT 6/ 6/2017 14:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 30 14.31 685 294 0.29 / 334.75 2 3
2 7 2001.88 49 11.16 3338 1825 2.12 / 336.58 2 2
3 13 1610.76 38 12.71 2791 1348 3.47 / 337.93 2 2
4 13 728.16 38 13.46 1589 813 4.28 / 338.74 2 2
5 8 0.00 170 14.02 534 1273 5.55 / 340.01 2 9
Average= 5.07 (KJ/cycle)

Cycle 65 GMT 27/ 5/2017 14: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 30 14.29 700 300 0.30 / 329.14 2 3
2 7 2003.36 49 11.20 3366 1847 2.15 / 330.99 2 2
3 13 1599.92 38 12.71 2813 1359 3.51 / 332.35 2 2
4 13 716.68 38 13.47 1610 824 4.33 / 333.17 2 2
5 8 0.24 170 14.00 542 1290 5.62 / 334.46 2 7
Average= 5.07 (KJ/cycle)

Cycle 64 GMT 17/ 5/2017 13:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 30 14.33 680 292 0.29 / 323.54 3 3
2 7 2005.28 49 11.24 3332 1835 2.13 / 325.37 3 2
3 13 1609.56 38 12.74 2773 1342 3.47 / 326.71 2 2
4 13 708.92 38 13.50 1579 810 4.28 / 327.52 2 2
5 8 0.20 170 14.01 553 1317 5.60 / 328.84 2 8
Average= 5.06 (KJ/cycle)

Cycle 63 GMT 7/ 5/2017 13:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 30 14.31 704 302 0.30 / 317.90 3 3
2 7 2009.64 49 11.31 3353 1858 2.16 / 319.76 3 2
3 13 1613.60 38 12.74 2838 1374 3.53 / 321.13 2 2
4 13 711.80 38 13.49 1587 814 4.35 / 321.95 2 3
5 8 0.08 170 14.01 544 1296 5.64 / 323.24 2 8
Average= 5.05 (KJ/cycle)

Cycle 62 GMT 27/ 4/2017 13:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 30 14.30 709 304 0.30 / 312.22 3 3
2 7 2005.52 49 11.38 3355 1871 2.17 / 314.09 2 2
3 13 1616.92 38 12.75 2838 1375 3.55 / 315.47 2 2
4 13 706.96 38 13.51 1588 815 4.37 / 316.28 2 2
5 8 0.04 170 14.01 553 1317 5.68 / 317.60 2 6
Average= 5.04 (KJ/cycle)

Cycle 61 GMT 17/ 4/2017 13:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 30 14.36 687 296 0.30 / 306.56 3 3
2 7 2002.20 49 11.44 3348 1877 2.17 / 308.44 3 2
3 13 1596.80 38 12.78 2819 1369 3.54 / 309.81 2 2
4 13 684.68 38 13.54 1540 792 4.33 / 310.60 2 2
5 8 0.12 170 14.02 554 1320 5.65 / 311.92 2 10
Average= 5.03 (KJ/cycle)

Cycle 60 GMT 7/ 4/2017 13:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 30 14.35 685 295 0.29 / 300.47 3 3
2 7 2001.96 49 11.52 3386 1911 2.21 / 302.38 3 2
3 13 1615.24 38 12.76 2850 1382 3.59 / 303.76 2 2
4 13 717.20 38 13.50 1638 840 4.43 / 304.60 2 2
5 13 29.28 38 14.20 644 348 4.78 / 304.95 2 3
6 8 -0.04 170 13.97 554 1316 6.09 / 306.26 2 10
Average= 5.02 (KJ/cycle)

Cycle 59 GMT 28/ 3/2017 13:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 30 14.37 680 293 0.29 / 294.88 2 3
2 7 2003.88 49 11.63 3371 1921 2.21 / 296.80 3 2
3 13 1598.28 38 12.84 2772 1353 3.57 / 298.16 2 2
4 13 515.44 38 13.70 1305 679 4.25 / 298.84 2 3
5 8 0.12 170 14.00 561 1335 5.58 / 300.17 2 9
Average= 5.00 (KJ/cycle)

Cycle 58 GMT 18/ 3/2017 13: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 30 14.36 695 299 0.30 / 289.20 3 3
2 7 2003.08 49 11.69 3379 1936 2.23 / 291.13 3 2
3 13 1605.32 38 12.84 2788 1360 3.60 / 292.49 2 2
4 13 679.32 38 13.57 1541 795 4.39 / 293.29 2 2
5 8 0.12 170 14.02 547 1304 5.69 / 294.59 2 6
Average= 4.99 (KJ/cycle)

Cycle 57 GMT 8/ 3/2017 13: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 30 14.37 699 301 0.30 / 283.50 3 3
2 7 2002.32 47 11.80 3411 1892 2.19 / 285.39 3 2
3 13 1599.88 38 12.83 2824 1377 3.57 / 286.77 2 2
4 13 681.28 38 13.57 1538 793 4.36 / 287.56 2 3
5 8 -0.04 175 14.02 545 1337 5.70 / 288.90 2 11
Average= 4.98 (KJ/cycle)

Cycle 56 GMT 26/ 2/2017 12:59: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 30 14.37 704 303 0.30 / 277.76 3 3
2 7 2004.04 48 11.93 3360 1924 2.23 / 279.68 2 2
3 13 1622.44 38 12.86 2801 1369 3.60 / 281.05 2 2
4 13 691.40 38 13.58 1538 794 4.39 / 281.84 2 3
5 8 0.20 175 14.01 552 1353 5.74 / 283.20 2 9
Average= 4.97 (KJ/cycle)

Cycle 55 GMT 16/ 2/2017 13: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 30 14.38 691 298 0.30 / 272.04 3 3
2 7 2004.40 48 11.96 3386 1944 2.24 / 273.98 3 2
3 13 1613.20 38 12.89 2773 1358 3.60 / 275.34 2 2
4 13 668.84 38 13.59 1543 797 4.40 / 276.14 2 3
5 8 0.00 175 14.04 536 1317 5.71 / 277.45 2 8
Average= 4.95 (KJ/cycle)

Cycle 54 GMT 6/ 2/2017 12:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 30 14.41 669 289 0.29 / 266.33 3 3
2 7 2006.84 47 12.04 3364 1904 2.19 / 268.23 3 2
3 13 1608.24 33 12.97 2756 1180 3.37 / 269.41 2 2
4 13 704.72 33 13.63 1562 703 4.07 / 270.11 2 3
5 13 19.20 33 14.26 625 294 4.37 / 270.41 2 2
6 8 0.08 175 14.00 543 1330 5.70 / 271.74 2 12
Average= 4.94 (KJ/cycle)

Cycle 53 GMT 27/ 1/2017 12:43: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 30 14.41 664 287 0.29 / 260.60 3 3
2 7 2003.72 47 12.10 3404 1936 2.22 / 262.53 2 2
3 13 1603.52 33 12.98 2762 1183 3.41 / 263.72 2 2
4 13 711.60 33 13.61 1582 711 4.12 / 264.43 2 2
5 13 23.12 33 14.27 621 292 4.41 / 264.72 2 3
6 8 -0.04 175 14.01 539 1321 5.73 / 266.04 2 10
Average= 4.93 (KJ/cycle)

Cycle 52 GMT 17/ 1/2017 12:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 30 14.40 655 283 0.28 / 254.83 3 3
2 7 2002.48 47 12.14 3361 1918 2.20 / 256.75 2 2
3 13 1602.16 33 12.97 2757 1180 3.38 / 257.93 2 2
4 13 708.88 33 13.61 1613 724 4.11 / 258.65 2 2
5 13 18.56 33 14.29 593 280 4.38 / 258.93 2 2
6 8 0.04 190 13.97 518 1375 5.76 / 260.31 2 11
Average= 4.91 (KJ/cycle)

Cycle 51 GMT 7/ 1/2017 12:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 30 14.44 648 281 0.28 / 249.06 3 3
2 7 2009.12 47 12.17 3400 1945 2.23 / 251.00 3 2
3 13 1594.60 33 12.99 2754 1181 3.41 / 252.18 2 2
4 13 690.52 33 13.67 1479 667 4.07 / 252.85 2 3
5 13 3.32 33 14.35 534 253 4.33 / 253.10 2 3
6 8 0.04 190 13.98 544 1445 5.77 / 254.55 2 12
Average= 4.90 (KJ/cycle)

Cycle 50 GMT 28/12/2016 12:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 30 14.37 690 297 0.30 / 243.63 2 3
2 7 2002.44 48 12.13 3398 1978 2.28 / 245.61 2 2
3 13 1584.16 33 12.99 2721 1166 3.44 / 246.77 2 2
4 13 696.04 33 13.64 1524 686 4.13 / 247.46 2 3
5 8 0.12 190 14.11 492 1319 5.45 / 248.78 2 8
Average= 4.88 (KJ/cycle)

Cycle 49 GMT 18/12/2016 12: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 30 14.41 658 284 0.28 / 238.39 3 3
2 7 2001.84 47 12.17 3365 1925 2.21 / 240.32 2 2
3 13 1422.76 33 13.11 2466 1067 3.28 / 241.38 2 2
4 13 564.08 33 13.79 1287 586 3.86 / 241.97 2 3
5 8 -0.04 190 14.09 509 1363 5.22 / 243.33 2 4
Average= 4.87 (KJ/cycle)

Cycle 48 GMT 8/12/2016 11:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 30 14.41 688 297 0.30 / 233.04 2 3
2 7 2009.12 47 12.18 3366 1927 2.22 / 234.97 2 2
3 13 1598.88 33 12.96 2768 1184 3.41 / 236.16 2 2
4 13 692.92 33 13.68 1466 662 4.07 / 236.82 2 2
5 8 0.08 190 14.14 480 1290 5.36 / 238.11 2 10
Average= 4.86 (KJ/cycle)

Cycle 47 GMT 28/11/2016 11:34: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 29 14.43 625 262 0.26 / 227.61 2 3
2 7 2008.36 48 12.20 3374 1976 2.24 / 229.58 2 2
3 13 1591.40 33 12.95 2754 1177 3.41 / 230.76 2 2
4 13 704.60 33 13.66 1519 685 4.10 / 231.44 2 3
5 8 0.40 190 14.11 486 1303 5.40 / 232.75 2 6
Average= 4.85 (KJ/cycle)

Cycle 46 GMT 18/11/2016 11: 9: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 29 14.43 616 258 0.26 / 222.33 2 3
2 7 2001.36 47 12.17 3382 1934 2.19 / 224.26 3 2
3 13 1581.72 33 12.99 2703 1159 3.35 / 225.42 2 2
4 13 670.28 33 13.70 1430 647 4.00 / 226.07 2 3
5 8 0.16 190 14.12 476 1277 5.27 / 227.35 2 6
Average= 4.84 (KJ/cycle)

Cycle 45 GMT 8/11/2016 11: 1: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 29 14.40 647 270 0.27 / 217.01 2 3
2 7 2004.68 47 12.18 3342 1913 2.18 / 218.92 2 2
3 13 1584.28 33 12.98 2718 1164 3.35 / 220.08 2 2
4 13 698.00 33 13.65 1515 682 4.03 / 220.77 2 2
5 8 0.16 190 14.13 486 1305 5.33 / 222.07 2 8
Average= 4.83 (KJ/cycle)

Cycle 44 GMT 29/10/2016 10:54: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 29 14.42 657 275 0.27 / 211.67 2 3
2 7 2009.32 49 12.19 3360 2007 2.28 / 213.68 3 2
3 13 1597.04 31 13.01 2754 1111 3.39 / 214.79 2 2
4 13 687.24 31 13.71 1455 618 4.01 / 215.41 2 3
5 8 0.12 190 14.10 495 1326 5.34 / 216.74 2 9
Average= 4.82 (KJ/cycle)

Cycle 43 GMT 19/10/2016 10:43:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 29 14.44 636 266 0.27 / 206.21 2 3
2 7 2001.24 49 12.22 3326 1992 2.26 / 208.20 2 2
3 13 1387.24 31 13.15 2468 1006 3.26 / 209.21 2 2
4 13 725.96 31 13.68 1529 648 3.91 / 209.86 2 3
5 13 41.32 31 14.36 575 256 4.17 / 210.12 2 2
6 8 0.00 190 14.08 480 1284 5.45 / 211.40 2 15
Average= 4.80 (KJ/cycle)

Cycle 42 GMT 9/10/2016 10:22: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 29 14.44 615 258 0.26 / 200.95 2 3
2 7 2006.92 48 12.23 3338 1960 2.22 / 202.91 2 2
3 13 1578.92 31 13.06 2670 1081 3.30 / 203.99 2 2
4 13 696.12 31 13.70 1493 634 3.93 / 204.63 2 3
5 8 0.04 190 14.14 492 1322 5.25 / 205.95 2 9
Average= 4.79 (KJ/cycle)

Cycle 41 GMT 29/ 9/2016 10:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 29 14.49 592 249 0.25 / 195.73 2 3
2 7 2003.72 48 12.26 3328 1958 2.21 / 197.69 3 2
3 13 1574.84 31 13.04 2716 1098 3.31 / 198.78 2 2
4 13 703.16 31 13.72 1471 626 3.93 / 199.41 2 3
5 8 0.08 190 14.17 477 1284 5.22 / 200.69 2 7
Average= 4.78 (KJ/cycle)

Cycle 40 GMT 19/ 9/2016 9:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 29 14.49 616 259 0.26 / 190.61 2 3
2 7 2003.20 48 12.32 3349 1980 2.24 / 192.59 2 2
3 13 1400.04 31 13.23 2390 980 3.22 / 193.57 2 2
4 13 738.84 31 13.70 1549 658 3.88 / 194.23 2 3
5 8 0.12 190 14.18 465 1253 5.13 / 195.48 2 6
Average= 4.77 (KJ/cycle)

Cycle 39 GMT 9/ 9/2016 9:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 29 14.48 626 263 0.26 / 185.49 2 3
2 7 2008.16 48 12.34 3368 1995 2.26 / 187.48 2 2
3 13 1403.96 31 13.23 2406 987 3.24 / 188.47 2 2
4 13 725.96 31 13.77 1471 628 3.87 / 189.10 2 3
5 8 0.08 190 14.19 463 1248 5.12 / 190.35 2 7
Average= 4.76 (KJ/cycle)

Cycle 38 GMT 30/ 8/2016 9:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 29 14.50 622 262 0.26 / 180.41 2 3
2 7 2001.48 48 12.36 3336 1979 2.24 / 182.39 3 2
3 13 1396.64 31 13.23 2429 996 3.24 / 183.39 2 2
4 13 553.68 31 13.89 1256 541 3.78 / 183.93 2 3
5 8 0.16 190 14.18 482 1299 5.08 / 185.23 2 8
Average= 4.75 (KJ/cycle)

Cycle 37 GMT 20/ 8/2016 8:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 29 14.49 618 260 0.26 / 175.19 2 3
2 7 2006.80 48 12.40 3350 1994 2.25 / 177.18 3 2
3 13 1591.60 31 13.11 2735 1112 3.37 / 178.29 2 2
4 13 692.28 31 13.79 1452 621 3.99 / 178.91 2 3
5 8 0.04 190 14.22 458 1237 5.22 / 180.15 2 13
Average= 4.74 (KJ/cycle)

Cycle 36 GMT 10/ 8/2016 8:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 29 14.52 615 259 0.26 / 170.17 2 3
2 7 2003.72 49 12.43 3318 2021 2.28 / 172.19 2 2
3 13 1383.12 31 13.24 2454 1007 3.29 / 173.20 2 2
4 13 517.44 31 13.94 1218 526 3.81 / 173.72 2 3
5 8 0.16 190 14.23 446 1206 5.02 / 174.93 2 7
Average= 4.73 (KJ/cycle)

Cycle 35 GMT 31/ 7/2016 8:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 29 14.53 613 258 0.26 / 165.10 2 3
2 7 2003.92 48 12.49 3342 2004 2.26 / 167.11 3 2
3 13 1397.48 31 13.26 2456 1010 3.27 / 168.12 2 2
4 13 559.72 31 13.93 1287 556 3.83 / 168.67 2 2
5 8 0.12 190 14.23 457 1236 5.06 / 169.91 2 7
Average= 4.72 (KJ/cycle)

Cycle 34 GMT 21/ 7/2016 7:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 29 14.52 609 256 0.26 / 160.03 2 3
2 7 2006.72 48 12.53 3334 2005 2.26 / 162.03 2 2
3 13 1394.40 31 13.31 2385 984 3.25 / 163.02 2 2
4 13 720.92 31 13.80 1494 639 3.88 / 163.66 2 3
5 8 0.12 190 14.24 439 1188 5.07 / 164.85 2 11
Average= 4.71 (KJ/cycle)

Cycle 33 GMT 11/ 7/2016 7:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 29 14.56 602 254 0.25 / 154.83 2 3
2 7 2007.04 49 12.57 3316 2042 2.30 / 156.88 3 2
3 13 1392.48 31 13.34 2348 971 3.27 / 157.85 2 2
4 13 530.84 31 14.00 1204 523 3.79 / 158.37 2 2
5 13 24.12 31 14.50 507 228 4.02 / 158.60 2 2
6 8 0.00 190 14.21 435 1174 5.19 / 159.77 2 8
Average= 4.70 (KJ/cycle)

Cycle 32 GMT 1/ 7/2016 6:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 29 14.59 578 245 0.24 / 149.81 2 3
2 7 2002.28 48 12.66 3297 2004 2.25 / 151.81 2 2
3 13 1563.72 25 13.34 2646 882 3.13 / 152.69 2 2
4 13 717.12 25 13.94 1456 507 3.64 / 153.20 2 3
5 13 59.88 25 14.51 547 198 3.84 / 153.40 2 2
6 8 0.04 190 14.23 437 1182 5.02 / 154.58 2 11
Average= 4.68 (KJ/cycle)

Cycle 31 GMT 21/ 6/2016 6:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 29 14.56 607 256 0.26 / 144.71 2 3
2 7 2006.20 48 12.69 3306 2014 2.27 / 146.72 3 2
3 13 1563.12 25 13.37 2606 871 3.14 / 147.59 2 2
4 13 897.08 25 13.81 1695 585 3.73 / 148.18 2 3
5 13 96.20 25 14.48 584 211 3.94 / 148.39 2 2
6 8 -0.12 190 14.25 433 1172 5.11 / 149.56 2 9
Average= 4.67 (KJ/cycle)

Cycle 30 GMT 11/ 6/2016 6:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 29 14.60 582 246 0.25 / 139.61 2 3
2 7 2002.88 50 12.70 3328 2113 2.36 / 141.72 3 2
3 13 1374.92 25 13.51 2316 782 3.14 / 142.50 2 2
4 13 729.52 25 13.94 1477 515 3.66 / 143.02 2 3
5 13 116.52 25 14.45 630 228 3.88 / 143.24 2 2
6 8 0.36 190 14.25 446 1208 5.09 / 144.45 2 10
Average= 4.66 (KJ/cycle)

Cycle 29 GMT 1/ 6/2016 5:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 29 14.58 618 261 0.26 / 134.57 2 3
2 7 2003.88 51 12.75 3311 2153 2.41 / 136.72 3 2
3 13 1368.32 25 13.52 2312 781 3.20 / 137.50 2 2
4 13 723.12 25 13.97 1455 508 3.70 / 138.01 2 3
5 13 26.80 25 14.58 494 180 3.88 / 138.19 2 2
6 8 0.04 190 14.25 433 1172 5.06 / 139.36 2 12
Average= 4.65 (KJ/cycle)

Cycle 28 GMT 22/ 5/2016 5:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 29 14.61 583 247 0.25 / 129.45 2 3
2 7 2004.04 50 12.79 3293 2106 2.35 / 131.55 3 2
3 13 1375.64 25 13.52 2360 798 3.15 / 132.35 2 2
4 13 733.24 25 13.96 1485 518 3.67 / 132.87 2 3
5 13 60.80 25 14.55 558 203 3.87 / 133.07 2 2
6 8 0.00 190 14.25 455 1232 5.10 / 134.30 2 8
Average= 4.63 (KJ/cycle)

Cycle 27 GMT 12/ 5/2016 4:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 29 14.60 624 264 0.26 / 124.28 2 3
2 7 2004.52 51 12.81 3293 2151 2.42 / 126.44 2 2
3 13 1384.68 25 13.53 2348 794 3.21 / 127.23 2 2
4 13 733.60 25 13.98 1468 513 3.72 / 127.74 2 3
5 13 28.84 25 14.56 550 200 3.92 / 127.94 2 2
6 8 0.24 190 14.23 465 1257 5.18 / 129.20 2 8
Average= 4.61 (KJ/cycle)

Cycle 26 GMT 2/ 5/2016 4:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 29 14.61 588 249 0.25 / 119.16 2 3
2 7 2002.00 50 12.87 3255 2095 2.34 / 121.26 3 2
3 13 1364.44 25 13.55 2348 795 3.14 / 122.05 2 2
4 13 721.16 25 13.99 1475 516 3.65 / 122.57 2 2
5 13 52.44 25 14.54 571 208 3.86 / 122.78 2 2
6 8 0.08 190 14.27 458 1242 5.10 / 124.02 2 15
Average= 4.59 (KJ/cycle)

Cycle 25 GMT 22/ 4/2016 3:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 28 14.64 573 235 0.23 / 114.25 2 3
2 7 2003.84 50 12.91 3187 2057 2.29 / 116.31 2 2
3 13 1370.76 25 13.57 2293 778 3.07 / 117.09 2 2
4 13 550.48 25 14.11 1251 441 3.51 / 117.53 2 3
5 13 39.56 25 14.57 546 199 3.71 / 117.73 2 3
6 8 0.12 190 14.27 439 1190 4.90 / 118.92 2 14
Average= 4.57 (KJ/cycle)

Cycle 24 GMT 12/ 4/2016 3:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 28 14.65 574 235 0.24 / 109.24 2 3
2 7 2002.04 50 12.85 3290 2114 2.35 / 111.35 2 2
3 13 1366.44 25 13.55 2353 797 3.15 / 112.15 2 2
4 13 700.44 25 14.03 1416 497 3.64 / 112.64 2 3
5 13 52.00 25 14.59 517 189 3.83 / 112.83 2 3
6 8 0.00 190 14.27 436 1182 5.01 / 114.02 2 12
Average= 4.56 (KJ/cycle)

Cycle 23 GMT 2/ 4/2016 2:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 28 14.65 568 233 0.23 / 104.26 3 3
2 7 2004.28 51 12.96 3188 2107 2.34 / 106.37 2 2
3 13 1353.36 25 13.60 2262 769 3.11 / 107.14 2 2
4 13 710.00 25 14.04 1421 499 3.61 / 107.64 2 2
5 13 53.08 25 14.57 540 197 3.80 / 107.83 2 2
6 8 0.04 190 14.28 431 1169 4.97 / 109.00 2 12
Average= 4.54 (KJ/cycle)

Cycle 22 GMT 23/ 3/2016 2:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 28 14.66 573 235 0.24 / 99.31 2 3
2 7 2003.20 51 12.97 3169 2096 2.33 / 101.40 2 2
3 13 1361.16 25 13.60 2268 771 3.10 / 102.18 2 2
4 13 694.96 25 14.05 1387 487 3.59 / 102.66 2 3
5 13 47.76 25 14.57 539 196 3.79 / 102.86 2 2
6 8 0.20 190 14.27 431 1169 4.95 / 104.03 2 9
Average= 4.52 (KJ/cycle)

Cycle 21 GMT 13/ 3/2016 2: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 28 14.67 566 232 0.23 / 94.39 2 3
2 7 2008.08 50 12.96 3211 2081 2.31 / 96.47 2 2
3 13 1360.80 25 13.61 2273 773 3.09 / 97.24 2 2
4 13 713.44 25 14.04 1424 500 3.59 / 97.74 2 3
5 13 53.44 25 14.58 524 191 3.78 / 97.93 2 2
6 8 0.04 190 14.31 419 1139 4.92 / 99.07 2 8
Average= 4.50 (KJ/cycle)

Cycle 20 GMT 3/ 3/2016 1:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 28 14.66 571 234 0.23 / 89.49 2 3
2 7 2002.56 50 12.99 3184 2068 2.30 / 91.55 2 2
3 13 1369.16 25 13.59 2319 788 3.09 / 92.34 2 2
4 13 715.04 25 14.05 1410 495 3.59 / 92.84 2 2
5 13 46.84 25 14.59 508 185 3.77 / 93.02 2 2
6 8 0.32 190 14.28 418 1134 4.90 / 94.16 2 13
Average= 4.48 (KJ/cycle)

Cycle 19 GMT 22/ 2/2016 1: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 28 14.67 574 236 0.24 / 84.56 3 3
2 7 2005.12 50 13.01 3152 2050 2.29 / 86.61 3 2
3 13 1388.48 25 13.61 2284 777 3.06 / 87.39 2 2
4 13 741.00 25 14.03 1456 511 3.57 / 87.90 2 3
5 13 61.72 25 14.58 547 199 3.77 / 88.10 2 2
6 8 0.16 190 14.31 424 1153 4.93 / 89.25 2 11
Average= 4.46 (KJ/cycle)

Cycle 18 GMT 12/ 2/2016 0:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 28 14.68 563 231 0.23 / 79.65 2 3
2 7 2002.64 50 13.01 3182 2070 2.30 / 81.72 2 2
3 13 1352.24 25 13.62 2280 776 3.08 / 82.50 2 2
4 13 708.28 25 14.05 1411 496 3.57 / 82.99 2 2
5 13 50.76 25 14.60 516 188 3.76 / 83.18 2 2
6 8 -0.16 190 14.31 420 1142 4.90 / 84.33 2 15
Average= 4.44 (KJ/cycle)

Cycle 17 GMT 1/ 2/2016 23:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 28 14.68 531 218 0.22 / 74.73 2 3
2 7 2002.60 50 13.00 3183 2069 2.29 / 76.80 2 2
3 13 1563.96 25 13.51 2547 860 3.15 / 77.66 2 2
4 13 662.60 25 14.09 1335 470 3.62 / 78.13 2 3
5 13 41.80 25 14.62 486 178 3.80 / 78.31 2 3
6 8 0.00 190 14.29 409 1110 4.91 / 79.42 2 12
Average= 4.41 (KJ/cycle)

Cycle 16 GMT 22/ 1/2016 23:26: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 28 14.67 571 235 0.23 / 69.85 2 3
2 7 2005.92 51 13.01 3171 2104 2.34 / 71.96 3 2
3 13 1382.08 25 13.60 2288 778 3.12 / 72.73 2 2
4 13 726.28 25 14.03 1438 504 3.62 / 73.24 2 3
5 13 53.36 25 14.60 508 185 3.81 / 73.42 2 2
6 8 0.12 190 14.30 402 1092 4.90 / 74.52 2 15
Average= 4.38 (KJ/cycle)

Cycle 15 GMT 12/ 1/2016 22:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 28 14.68 567 233 0.23 / 64.97 2 3
2 7 2002.20 50 13.02 3153 2053 2.29 / 67.02 2 2
3 13 1334.32 25 13.61 2254 767 3.05 / 67.79 2 2
4 13 695.68 25 14.07 1398 492 3.54 / 68.28 2 3
5 13 49.84 25 14.60 520 190 3.73 / 68.47 2 2
6 8 0.12 190 14.29 422 1146 4.88 / 69.62 2 10
Average= 4.35 (KJ/cycle)

Cycle 14 GMT 2/ 1/2016 22:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 27 14.67 570 226 0.23 / 60.14 2 3
2 7 2006.60 50 13.00 3182 2068 2.29 / 62.21 2 2
3 13 1331.76 25 13.64 2229 760 3.05 / 62.97 2 2
4 13 668.12 25 14.09 1334 470 3.52 / 63.44 2 2
5 13 24.32 25 14.64 477 175 3.70 / 63.61 2 2
6 8 0.04 190 14.29 414 1124 4.82 / 64.74 2 9
Average= 4.32 (KJ/cycle)

Cycle 13 GMT 23/12/2015 22: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 27 14.70 517 205 0.21 / 55.45 2 3
2 7 2003.20 50 13.02 3121 2032 2.24 / 57.49 2 2
3 13 1361.72 25 13.63 2215 755 2.99 / 58.24 2 2
4 13 707.40 25 14.09 1351 476 3.47 / 58.72 2 2
5 13 45.32 25 14.65 453 166 3.63 / 58.88 2 2
6 8 0.00 190 14.33 379 1032 4.67 / 59.91 2 11
Average= 4.28 (KJ/cycle)

Cycle 12 GMT 13/12/2015 21:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 27 14.69 522 207 0.21 / 50.79 2 2
2 7 2003.84 51 13.02 3129 2078 2.28 / 52.86 2 2
3 13 1364.88 25 13.63 2198 749 3.03 / 53.61 2 2
4 13 696.56 25 14.09 1324 466 3.50 / 54.08 2 3
5 13 44.84 25 14.65 438 160 3.66 / 54.24 2 2
6 8 0.00 190 14.33 371 1010 4.67 / 55.25 2 9
Average= 4.25 (KJ/cycle)

Cycle 11 GMT 3/12/2015 21: 6: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 27 14.67 518 205 0.21 / 46.25 2 3
2 7 2003.28 50 13.02 3105 2021 2.23 / 48.27 3 2
3 13 1364.92 25 13.63 2216 755 2.98 / 49.02 2 2
4 13 539.28 25 14.20 1118 397 3.38 / 49.42 2 3
5 13 27.72 25 14.67 423 155 3.53 / 49.57 2 2
6 8 -0.04 190 14.33 369 1005 4.54 / 50.58 2 15
Average= 4.21 (KJ/cycle)

Cycle 10 GMT 23/11/2015 20:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 27 14.66 516 204 0.20 / 41.69 2 3
2 7 2004.40 50 13.02 3084 2008 2.21 / 43.70 3 2
3 13 1352.04 25 13.63 2176 741 2.95 / 44.44 2 2
4 13 704.12 25 14.08 1307 460 3.41 / 44.90 2 3
5 13 46.80 25 14.64 441 161 3.57 / 45.06 2 2
6 8 0.20 190 14.32 361 982 4.56 / 46.04 2 10
Average= 4.19 (KJ/cycle)

Cycle 9 GMT 13/11/2015 19:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 27 14.63 517 204 0.20 / 37.10 2 2
2 7 2006.28 51 13.01 3117 2068 2.27 / 39.16 2 2
3 13 1328.12 25 13.62 2171 739 3.01 / 39.90 2 2
4 13 668.00 25 14.09 1286 453 3.46 / 40.36 2 2
5 13 17.80 25 14.68 400 147 3.61 / 40.50 2 2
6 8 0.00 190 14.33 360 980 4.59 / 41.48 2 9
Average= 4.15 (KJ/cycle)

Cycle 8 GMT 3/11/2015 19:22: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 27 14.64 502 198 0.20 / 32.59 2 2
2 7 2002.68 50 13.01 3084 2006 2.20 / 34.59 2 2
3 13 1349.76 25 13.61 2146 730 2.93 / 35.32 2 2
4 13 690.84 25 14.07 1298 457 3.39 / 35.78 2 3
5 13 21.64 25 14.68 401 147 3.54 / 35.93 2 2
6 8 0.00 190 14.32 355 966 4.50 / 36.89 2 8
Average= 4.10 (KJ/cycle)

Cycle 7 GMT 24/10/2015 18:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 26 14.63 543 207 0.21 / 27.49 2 2
2 3 1025.56 1 14.50 1860 27 0.23 / 27.51 2 2
3 7 2003.36 75 12.81 3085 2964 3.20 / 30.48 2 2
4 13 986.64 20 13.90 1699 472 3.67 / 30.95 2 3
5 13 277.24 20 14.45 756 218 3.89 / 31.17 2 2
6 8 0.40 240 14.32 355 1220 5.11 / 32.39 2 15
Average= 4.05 (KJ/cycle)

Cycle 6 GMT 14/10/2015 18:30: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 26 14.61 509 193 0.19 / 22.46 2 2
2 7 2002.84 74 12.79 3094 2928 3.12 / 25.39 2 2
3 13 968.16 20 13.89 1659 461 3.58 / 25.85 2 3
4 13 264.36 20 14.44 730 211 3.79 / 26.06 2 3
5 8 0.00 240 14.30 355 1218 5.01 / 27.28 2 17
Average= 3.90 (KJ/cycle)

Cycle 5 GMT 4/10/2015 18:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 25 14.64 502 184 0.18 / 17.42 2 2
2 3 1022.04 1 14.41 1872 27 0.21 / 17.45 2 2
3 7 2001.40 75 12.75 3070 2936 3.15 / 20.39 2 2
4 13 957.60 20 13.86 1668 462 3.61 / 20.85 2 2
5 13 256.48 20 14.44 718 207 3.82 / 21.06 2 3
6 8 0.28 240 14.30 353 1211 5.03 / 22.27 2 13
Average= 3.71 (KJ/cycle)

Cycle 4 GMT 24/ 9/2015 18:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 26 14.57 491 186 0.19 / 13.32 2 2
2 7 1503.32 74 13.13 2392 2324 2.51 / 15.65 2 2
3 13 559.04 20 14.15 1118 316 2.83 / 15.96 2 3
4 13 1.44 20 14.72 350 103 2.93 / 16.07 2 2
5 8 0.12 240 14.25 343 1173 4.10 / 17.24 2 12
Average= 3.45 (KJ/cycle)

Cycle 3 GMT 23/ 9/2015 19: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 26 14.58 490 186 0.19 / 9.14 2 2
2 3 967.28 -1 14.58 490 0 0.00 / 9.14 2 2
3 3 1038.12 1 14.36 1849 27 0.21 / 9.16 2 2
4 7 1514.36 75 13.01 2424 2365 2.58 / 11.53 2 2
5 13 547.52 20 14.13 1095 309 2.89 / 11.84 2 3
6 13 73.72 20 14.58 452 132 3.02 / 11.97 2 2
7 8 0.04 240 14.24 342 1169 4.19 / 13.14 2 12
Average= 3.28 (KJ/cycle)

Cycle 2 GMT 22/ 9/2015 19:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 25 14.54 497 181 0.18 / 4.98 2 2
2 3 1055.60 1 14.23 1857 26 0.21 / 5.01 2 2
3 7 1517.04 74 12.84 2437 2316 2.52 / 7.33 2 2
4 13 580.84 20 14.02 1136 319 2.84 / 7.65 2 3
5 13 89.40 20 14.51 475 138 2.98 / 7.78 2 2
6 8 0.12 240 14.21 342 1166 4.15 / 8.95 2 15
Average= 2.98 (KJ/cycle)

Cycle 1 GMT 21/ 9/2015 20:22: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 25 14.52 502 182 0.18 / 1.96 2 3
2 7 1004.84 75 13.12 1699 1672 1.85 / 3.63 2 2
3 8 0.00 240 14.17 344 1170 3.02 / 4.80 2 16
Average= 2.40 (KJ/cycle)

Cycle 0 GMT 21/ 9/2015 8:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 91.32 24 14.43 482 167 0.17 / 0.17 2 3
2 7 99.68 75 14.15 485 515 0.68 / 0.68 3 3
3 8 0.32 240 14.26 321 1099 1.78 / 1.78 3 52
Average= 1.78 (KJ/cycle)