SIO Argo Site:
Pump Diagnostics Page   



Serial= 8297 WMO= 5902375

Return

←PreviousNext→

Cycle 3 GMT 3/12/2014 21:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 27 14.63 477 188 0.19 / 8.93 2 2
2 7 1514.60 74 13.05 2529 2442 2.63 / 11.37 2 2
3 13 781.60 20 13.95 1487 415 3.05 / 11.78 2 2
4 13 16.92 20 14.78 343 101 3.15 / 11.89 2 2
5 14 -0.04 240 14.23 370 1264 4.41 / 13.15 2 22
Average= 3.29 (KJ/cycle)

Cycle 2 GMT 2/12/2014 22:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 24 14.63 469 165 0.16 / 4.65 2 2
2 10 1015.04 3 14.40 1863 80 0.25 / 4.73 2 2
3 7 1501.76 74 12.92 2519 2408 2.65 / 7.14 2 2
4 13 769.60 20 13.90 1461 406 3.06 / 7.54 2 2
5 13 140.48 20 14.56 527 153 3.21 / 7.70 2 2
6 14 0.08 241 14.33 302 1043 4.26 / 8.74 2 22
Average= 2.91 (KJ/cycle)

Cycle 1 GMT 1/12/2014 23:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 27 14.54 461 181 0.18 / 1.72 2 2
2 7 998.20 74 13.15 1788 1740 1.92 / 3.46 2 2
3 14 -0.04 240 14.30 297 1019 2.94 / 4.48 2 22
Average= 2.24 (KJ/cycle)

Cycle 0 GMT 1/12/2014 12:14: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 76.36 26 14.32 408 152 0.15 / 0.15 2 2
2 7 82.56 75 14.16 409 434 0.59 / 0.59 2 2
3 14 -0.00 241 14.28 278 957 1.54 / 1.54 2 31
Average= 1.54 (KJ/cycle)