SIO Argo Site:
Pump Diagnostics Page   



Serial= 8263 WMO= 5902354

Return

←PreviousNext→

Cycle 308 GMT 20/ 3/2022 3:28: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 41 10.48 387 166 0.17 / 1449.15 2 2
2 12 1136.92 91 6.04 1895 1042 1.21 / 1450.19 1 2
3 7 1144.16 21 6.09 1889 242 1.45 / 1450.43 2 2
4 13 1058.32 32 6.48 1786 370 1.82 / 1450.81 1 2
5 13 925.84 32 6.89 1601 353 2.17 / 1451.16 1 2
6 13 746.44 32 7.74 1338 331 2.50 / 1451.49 1 1
7 13 314.08 32 9.42 726 219 2.72 / 1451.71 1 2
8 13 62.40 32 10.42 347 116 2.84 / 1451.82 1 2
9 14 -0.04 180 10.73 242 467 3.31 / 1452.29 1 2
Average= 4.70 (KJ/cycle)

Cycle 307 GMT 10/ 3/2022 8:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 41 10.53 379 164 0.16 / 1445.86 2 2
2 12 1118.32 91 6.27 1869 1066 1.23 / 1446.93 1 1
3 7 1125.76 21 6.20 1879 245 1.47 / 1447.17 1 2
4 13 1034.52 32 6.73 1751 377 1.85 / 1447.55 1 2
5 13 867.64 32 7.33 1513 355 2.21 / 1447.90 1 2
6 13 679.96 32 8.12 1243 323 2.53 / 1448.22 1 2
7 13 219.36 32 9.84 579 182 2.71 / 1448.41 1 2
8 13 38.32 32 10.53 311 105 2.82 / 1448.51 1 2
9 14 -0.16 180 10.73 245 473 3.29 / 1448.99 1 2
Average= 4.70 (KJ/cycle)

Cycle 306 GMT 28/ 2/2022 13:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 42 10.55 394 175 0.17 / 1442.70 2 2
2 12 1103.20 91 6.53 1846 1097 1.27 / 1443.79 1 2
3 7 1108.48 21 6.47 1839 250 1.52 / 1444.04 2 2
4 13 1000.16 32 6.98 1702 380 1.90 / 1444.42 1 1
5 13 841.76 32 7.58 1475 358 2.26 / 1444.78 1 1
6 13 640.36 32 8.37 1189 318 2.58 / 1445.10 1 2
7 13 83.84 32 10.39 378 126 2.70 / 1445.22 2 2
8 14 0.08 180 10.76 243 471 3.17 / 1445.70 2 2
Average= 4.71 (KJ/cycle)

Cycle 305 GMT 18/ 2/2022 18:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 43 10.59 381 173 0.17 / 1439.96 2 2
2 3 970.76 -1 10.59 381 0 0.00 / 1439.96 2 2
3 3 1050.00 1 7.14 1797 13 0.19 / 1439.97 1 1
4 12 1052.00 4 7.02 1799 51 0.24 / 1440.02 1 1
5 12 1192.44 91 6.20 1978 1116 1.35 / 1441.14 1 2
6 7 1185.00 21 6.00 1952 246 1.60 / 1441.38 2 1
7 13 750.48 32 7.95 1363 347 1.95 / 1441.73 1 2
8 13 302.16 32 9.63 705 217 2.16 / 1441.95 1 2
9 13 35.12 32 10.60 306 104 2.27 / 1442.05 1 2
10 14 -0.28 180 10.77 242 469 2.74 / 1442.52 2 2
Average= 4.71 (KJ/cycle)

Cycle 304 GMT 17/ 2/2022 15:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 40 10.65 375 160 0.16 / 1436.73 2 2
2 3 1026.72 1 7.52 1774 13 0.17 / 1436.75 1 1
3 12 1135.12 91 6.42 1882 1100 1.27 / 1437.85 1 2
4 7 1140.24 20 6.01 1879 226 1.50 / 1438.07 2 1
5 13 1038.24 32 6.91 1759 389 1.89 / 1438.46 1 1
6 13 894.60 32 7.47 1565 374 2.26 / 1438.83 1 1
7 13 694.40 32 8.22 1264 332 2.59 / 1439.17 1 2
8 13 112.24 33 10.31 421 143 2.74 / 1439.31 1 2
9 14 -0.12 181 10.76 244 475 3.21 / 1439.79 2 2
Average= 4.72 (KJ/cycle)

Cycle 303 GMT 7/ 2/2022 20:28: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 37 10.67 377 149 0.15 / 1433.44 2 2
2 3 1071.80 2 7.79 1840 29 0.18 / 1433.47 1 1
3 3 1051.08 1 7.94 1817 14 0.19 / 1433.48 1 1
4 12 1161.76 90 6.35 1939 1108 1.30 / 1434.59 1 2
5 7 1169.32 20 5.82 1943 226 1.53 / 1434.81 2 2
6 13 1071.28 32 6.97 1815 405 1.93 / 1435.22 1 2
7 13 910.16 32 7.60 1579 384 2.32 / 1435.60 1 1
8 13 715.20 32 8.27 1310 347 2.66 / 1435.95 1 2
9 13 128.52 32 10.31 449 148 2.81 / 1436.10 1 2
10 14 -0.16 181 10.80 243 475 3.28 / 1436.57 1 2
Average= 4.73 (KJ/cycle)

Cycle 302 GMT 29/ 1/2022 1:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 32 10.85 376 131 0.13 / 1429.87 2 2
2 10 1004.48 4 9.01 1720 62 0.19 / 1429.94 1 2
3 10 1035.20 3 8.82 1801 48 0.24 / 1429.98 1 2
4 3 1097.84 3 8.41 1918 48 0.29 / 1430.03 1 1
5 3 1053.72 1 8.78 1783 16 0.30 / 1430.05 1 2
6 12 1154.00 91 6.82 1937 1202 1.51 / 1431.25 1 2
7 7 1159.08 20 6.22 1918 239 1.74 / 1431.49 2 2
8 13 1033.76 32 7.56 1771 428 2.17 / 1431.92 1 1
9 13 862.08 33 8.16 1522 410 2.58 / 1432.33 1 1
10 13 441.48 32 9.48 916 278 2.86 / 1432.60 1 1
11 13 38.48 32 10.71 314 108 2.97 / 1432.71 1 2
12 13 20.56 32 10.77 280 96 3.07 / 1432.81 2 2
13 14 -0.12 181 10.85 244 479 3.54 / 1433.29 2 2
Average= 4.73 (KJ/cycle)

Cycle 301 GMT 19/ 1/2022 6:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 31 10.95 377 128 0.13 / 1427.02 2 2
2 10 1016.12 4 9.05 1768 64 0.19 / 1427.09 1 2
3 10 1054.84 3 9.05 1791 49 0.24 / 1427.14 1 2
4 3 1128.12 3 8.78 1890 50 0.29 / 1427.19 1 1
5 3 1078.40 2 8.68 1866 32 0.32 / 1427.22 1 1
6 12 1050.12 4 8.54 1831 63 0.39 / 1427.28 1 1
7 12 1175.56 91 7.77 1981 1401 1.79 / 1428.68 1 2
8 7 1165.68 20 7.17 1962 281 2.07 / 1428.96 2 1
9 13 219.20 32 10.39 588 195 2.26 / 1429.16 1 1
10 13 19.20 32 10.91 281 98 2.36 / 1429.26 1 2
11 14 0.00 181 10.96 245 486 2.85 / 1429.74 1 2
Average= 4.73 (KJ/cycle)

Cycle 300 GMT 18/ 1/2022 3:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 36 11.66 389 163 0.16 / 1423.63 2 2
2 3 1035.52 1 10.28 1798 18 0.18 / 1423.65 1 2
3 12 1140.28 90 6.27 1896 1070 1.25 / 1424.72 1 2
4 7 1148.20 20 6.24 1900 237 1.49 / 1424.95 2 2
5 13 1070.88 32 8.08 1836 475 1.96 / 1425.43 1 1
6 13 914.04 32 8.61 1607 443 2.41 / 1425.87 1 2
7 13 704.84 32 9.27 1308 388 2.79 / 1426.26 1 2
8 13 101.44 32 10.85 412 143 2.94 / 1426.40 1 2
9 14 -0.32 180 11.05 249 495 3.43 / 1426.90 1 2
Average= 4.74 (KJ/cycle)

Cycle 299 GMT 8/ 1/2022 8:51: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 30 12.46 419 157 0.16 / 1419.65 2 2
2 10 1032.88 3 11.69 1800 63 0.22 / 1419.72 1 2
3 3 1081.00 2 11.37 1913 44 0.26 / 1419.76 1 1
4 3 1035.00 1 11.37 1858 21 0.28 / 1419.78 1 2
5 12 1152.44 90 5.44 1886 923 1.21 / 1420.71 1 2
6 7 1162.24 20 7.66 1961 300 1.51 / 1421.01 2 1
7 13 1218.28 32 7.78 2043 509 2.02 / 1421.51 1 2
8 13 1102.20 32 8.43 1891 510 2.53 / 1422.02 1 2
9 13 911.56 32 9.17 1617 474 3.00 / 1422.50 1 2
10 13 467.60 32 10.50 974 327 3.33 / 1422.83 1 2
11 13 17.44 32 11.73 289 108 3.44 / 1422.93 2 2
12 14 0.08 180 11.58 254 529 3.97 / 1423.46 2 5
Average= 4.74 (KJ/cycle)

Cycle 298 GMT 29/12/2021 13:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 29 13.41 403 157 0.16 / 1416.29 2 2
2 3 1054.44 1 12.12 1863 23 0.18 / 1416.32 1 4
3 3 1031.28 1 11.89 1834 22 0.20 / 1416.34 1 3
4 12 1131.52 90 8.07 1918 1393 1.59 / 1417.73 1 1
5 7 1134.60 21 9.59 1938 390 1.98 / 1418.12 1 2
6 13 937.80 32 10.22 1669 546 2.53 / 1418.67 1 2
7 13 240.72 32 11.98 644 247 2.78 / 1418.91 1 2
8 14 -0.16 180 12.35 263 585 3.36 / 1419.50 2 2
Average= 4.75 (KJ/cycle)

Cycle 297 GMT 19/12/2021 19: 6:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 30 13.80 424 176 0.18 / 1411.15 2 2
2 3 1025.80 1 11.90 1831 22 0.20 / 1411.17 1 2
3 12 1136.20 4 11.81 1977 93 0.29 / 1411.26 1 2
4 12 1931.20 90 8.83 3081 2448 2.74 / 1413.71 1 1
5 7 1922.20 20 9.12 3065 559 3.30 / 1414.27 1 2
6 13 1215.04 32 10.64 2087 711 4.01 / 1414.98 1 1
7 13 510.40 32 12.05 1059 408 4.42 / 1415.39 1 2
8 13 3.44 32 13.30 282 120 4.54 / 1415.51 1 2
9 14 -0.08 180 12.99 269 629 5.17 / 1416.14 2 3
Average= 4.75 (KJ/cycle)

Cycle 296 GMT 18/12/2021 14:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 30 14.13 421 178 0.18 / 1406.75 2 2
2 12 1111.20 90 4.79 1632 704 0.88 / 1407.46 1 2
3 7 1121.72 20 8.70 1924 335 1.22 / 1407.79 2 1
4 13 1297.00 32 8.45 2162 585 1.80 / 1408.38 1 2
5 13 1250.56 32 9.21 2110 622 2.42 / 1409.00 1 1
6 13 1087.44 32 9.99 1882 602 3.02 / 1409.60 1 2
7 13 869.96 33 10.80 1582 564 3.59 / 1410.16 1 2
8 13 18.56 32 13.78 312 138 3.73 / 1410.30 1 2
9 14 -0.16 181 13.42 275 668 4.39 / 1410.97 1 4
Average= 4.75 (KJ/cycle)

Cycle 295 GMT 8/12/2021 18:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 30 14.18 419 178 0.18 / 1402.33 2 2
2 12 1117.00 90 4.75 1459 624 0.80 / 1402.96 1 2
3 7 1128.36 20 7.91 1914 303 1.10 / 1403.26 2 2
4 13 1285.16 32 8.18 2133 558 1.66 / 1403.82 1 2
5 13 1289.68 32 9.31 2163 644 2.31 / 1404.46 1 2
6 13 1132.48 32 10.34 1955 647 2.95 / 1405.11 1 2
7 13 912.92 32 11.32 1646 596 3.55 / 1405.71 1 2
8 13 35.52 33 14.11 346 161 3.71 / 1405.87 2 2
9 14 -0.16 181 13.95 280 707 4.42 / 1406.58 2 4
Average= 4.75 (KJ/cycle)

Cycle 294 GMT 28/11/2021 22:43:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 29 14.27 427 177 0.18 / 1398.63 2 2
2 12 1099.68 91 5.45 1808 897 1.07 / 1399.53 1 1
3 7 1111.12 21 9.38 1912 377 1.45 / 1399.91 1 2
4 13 1097.92 32 10.60 1900 644 2.09 / 1400.55 1 2
5 13 923.92 32 11.57 1664 616 2.71 / 1401.17 1 2
6 13 211.24 32 13.83 615 272 2.98 / 1401.44 1 2
7 14 -0.12 180 14.12 282 717 3.70 / 1402.16 2 4
Average= 4.75 (KJ/cycle)

Cycle 293 GMT 19/11/2021 3:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 30 14.26 425 182 0.18 / 1394.30 2 2
2 12 1107.68 4 10.87 1962 85 0.27 / 1394.38 1 1
3 12 1491.64 90 9.42 2459 2085 2.35 / 1396.47 1 1
4 7 1485.24 21 10.02 2463 518 2.87 / 1396.98 1 2
5 13 760.20 32 12.90 1459 602 3.47 / 1397.59 1 2
6 13 21.12 32 14.27 323 147 3.62 / 1397.73 1 2
7 14 -0.12 180 14.21 283 724 4.34 / 1398.46 2 8
Average= 4.76 (KJ/cycle)

Cycle 292 GMT 18/11/2021 0:30: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 30 14.26 426 182 0.18 / 1389.93 2 2
2 12 1123.40 90 4.76 1493 640 0.82 / 1390.57 1 2
3 7 1135.84 20 8.18 1953 320 1.14 / 1390.89 2 2
4 13 1293.36 32 9.13 2168 633 1.77 / 1391.52 1 2
5 13 1247.08 32 10.13 2117 686 2.46 / 1392.21 1 1
6 13 1074.84 32 11.12 1887 671 3.13 / 1392.88 1 2
7 13 623.24 32 12.82 1242 510 3.64 / 1393.39 1 2
8 14 -0.04 180 14.15 285 726 4.37 / 1394.11 1 6
Average= 4.76 (KJ/cycle)

Cycle 291 GMT 8/11/2021 4:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 30 14.20 433 184 0.18 / 1385.65 1 2
2 12 1109.44 90 4.76 1516 649 0.83 / 1386.30 1 2
3 7 1121.32 21 8.30 1928 336 1.17 / 1386.63 2 2
4 13 1290.96 32 9.16 2174 637 1.81 / 1387.27 1 1
5 13 1223.52 32 10.37 2086 692 2.50 / 1387.96 1 2
6 13 1044.56 32 11.31 1845 668 3.17 / 1388.63 1 2
7 13 391.88 32 13.45 891 383 3.55 / 1389.01 1 2
8 14 -0.12 180 14.20 287 734 4.28 / 1389.75 1 3
Average= 4.76 (KJ/cycle)

Cycle 290 GMT 29/10/2021 8:58: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 29 14.32 431 179 0.18 / 1382.08 2 2
2 12 1114.36 90 5.81 1853 969 1.15 / 1383.05 1 1
3 7 1123.64 20 9.61 1932 371 1.52 / 1383.42 1 2
4 13 1030.00 33 11.39 1814 682 2.20 / 1384.10 1 1
5 13 824.72 33 12.20 1527 615 2.82 / 1384.72 1 2
6 14 -0.16 181 14.22 289 744 3.56 / 1385.46 2 4
Average= 4.76 (KJ/cycle)

Cycle 289 GMT 19/10/2021 14:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 30 14.23 437 187 0.19 / 1377.71 1 2
2 12 1089.20 4 11.06 1913 85 0.27 / 1377.80 1 2
3 12 1559.36 91 9.44 2562 2201 2.47 / 1380.00 1 1
4 7 1553.24 21 10.12 2553 543 3.01 / 1380.54 1 2
5 13 808.00 32 13.02 1487 620 3.63 / 1381.16 1 2
6 14 -0.04 180 14.28 288 740 4.37 / 1381.90 1 2
Average= 4.77 (KJ/cycle)

Cycle 288 GMT 18/10/2021 11: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 30 14.25 436 186 0.19 / 1373.37 1 2
2 12 1111.68 91 4.77 1542 669 0.86 / 1374.04 1 2
3 7 1124.16 21 8.47 1937 345 1.20 / 1374.38 2 1
4 13 1277.44 32 9.60 2148 660 1.86 / 1375.04 1 2
5 13 1224.28 32 10.51 2092 704 2.56 / 1375.75 1 2
6 13 1044.52 32 11.48 1846 678 3.24 / 1376.42 1 3
7 13 357.28 32 13.57 843 366 3.61 / 1376.79 1 2
8 14 -0.08 180 14.27 287 737 4.35 / 1377.53 2 5
Average= 4.77 (KJ/cycle)

Cycle 287 GMT 8/10/2021 15:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 30 14.25 439 188 0.19 / 1368.99 1 2
2 12 1127.96 90 4.77 1574 676 0.86 / 1369.67 1 2
3 7 1140.48 20 8.43 1956 330 1.19 / 1370.00 2 1
4 13 1294.00 32 9.59 2164 664 1.86 / 1370.66 1 1
5 13 1219.64 32 10.66 2093 714 2.57 / 1371.38 1 1
6 13 1054.08 32 11.52 1859 685 3.26 / 1372.06 1 2
7 13 355.64 32 13.60 840 366 3.62 / 1372.43 1 2
8 14 -0.04 181 14.26 292 754 4.38 / 1373.18 2 4
Average= 4.77 (KJ/cycle)

Cycle 286 GMT 28/ 9/2021 19:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 29 14.33 421 175 0.17 / 1365.41 2 2
2 12 1105.40 90 6.12 1848 1018 1.19 / 1366.43 1 1
3 7 1115.12 20 9.78 1916 375 1.57 / 1366.80 1 2
4 13 1007.44 32 11.68 1793 670 2.24 / 1367.47 1 2
5 13 792.88 32 12.45 1496 596 2.83 / 1368.07 1 3
6 14 -0.16 180 14.30 287 739 3.57 / 1368.81 1 4
Average= 4.77 (KJ/cycle)

Cycle 285 GMT 19/ 9/2021 1: 3:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 30 14.26 439 188 0.19 / 1361.22 2 2
2 12 1096.88 4 11.23 1917 86 0.27 / 1361.31 1 2
3 12 1458.36 90 9.64 2416 2096 2.37 / 1363.41 1 2
4 7 1451.36 20 10.19 2422 494 2.86 / 1363.90 2 2
5 13 737.28 32 13.19 1402 592 3.46 / 1364.49 1 3
6 14 0.00 180 14.35 287 741 4.20 / 1365.23 2 2
Average= 4.77 (KJ/cycle)

Cycle 284 GMT 17/ 9/2021 21:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 30 14.25 429 183 0.18 / 1356.97 2 2
2 12 1105.40 90 4.78 1602 689 0.87 / 1357.66 1 2
3 7 1117.52 20 8.73 1925 336 1.21 / 1358.00 2 1
4 13 1267.56 32 9.96 2139 682 1.89 / 1358.68 1 2
5 13 1183.96 32 10.89 2029 707 2.60 / 1359.39 1 1
6 13 1003.88 32 11.73 1793 673 3.27 / 1360.06 1 2
7 13 155.48 32 14.06 532 239 3.51 / 1360.30 1 2
8 14 -0.12 180 14.33 286 738 4.25 / 1361.04 2 4
Average= 4.78 (KJ/cycle)

Cycle 283 GMT 8/ 9/2021 2: 9: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 30 14.26 435 186 0.19 / 1352.38 2 2
2 3 971.64 -1 14.26 435 0 0.00 / 1352.38 2 2
3 3 1043.44 1 10.97 1868 20 0.21 / 1352.40 1 1
4 12 1150.36 90 4.79 1631 703 0.91 / 1353.10 1 2
5 7 1162.64 21 8.60 1964 355 1.26 / 1353.46 2 1
6 13 1315.72 32 9.82 2205 693 1.96 / 1354.15 1 1
7 13 1231.40 32 10.83 2099 727 2.68 / 1354.88 1 2
8 13 1039.88 32 11.72 1835 688 3.37 / 1355.56 1 2
9 13 561.56 32 13.17 1153 486 3.86 / 1356.05 1 3
10 14 -0.08 180 14.30 287 739 4.60 / 1356.79 2 8
Average= 4.78 (KJ/cycle)

Cycle 282 GMT 29/ 8/2021 6:34: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 30 14.28 428 183 0.18 / 1348.50 2 2
2 3 967.20 -1 14.28 428 0 0.00 / 1348.50 2 2
3 3 1032.04 1 11.00 1847 20 0.20 / 1348.52 1 1
4 12 1139.28 90 5.39 1849 897 1.10 / 1349.41 1 1
5 7 1149.00 20 9.43 1966 371 1.47 / 1349.78 1 2
6 13 1127.48 32 11.23 1961 705 2.18 / 1350.49 1 1
7 13 952.88 32 11.97 1719 658 2.83 / 1351.15 1 2
8 13 248.48 32 13.88 676 300 3.13 / 1351.45 1 2
9 14 -0.12 180 14.31 289 744 3.88 / 1352.19 1 4
Average= 4.78 (KJ/cycle)

Cycle 281 GMT 19/ 8/2021 11:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 30 14.26 440 188 0.19 / 1343.33 2 2
2 12 1115.72 4 10.86 1967 85 0.27 / 1343.42 1 1
3 12 1911.88 90 8.05 3059 2216 2.49 / 1345.64 1 1
4 7 1903.68 20 9.88 3077 608 3.10 / 1346.24 1 2
5 13 1241.12 32 12.57 2089 840 3.94 / 1347.08 1 2
6 13 525.04 32 13.60 1105 481 4.42 / 1347.57 1 2
7 14 0.00 181 14.38 287 747 5.17 / 1348.31 2 5
Average= 4.78 (KJ/cycle)

Cycle 280 GMT 18/ 8/2021 7: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 30 14.24 440 188 0.19 / 1338.97 2 2
2 12 1132.40 91 4.79 1619 706 0.89 / 1339.67 1 2
3 7 1144.80 21 8.73 1963 360 1.25 / 1340.03 2 2
4 13 1301.00 32 10.02 2202 706 1.96 / 1340.74 1 1
5 13 1215.36 32 11.00 2086 734 2.69 / 1341.47 1 2
6 13 1005.04 33 11.85 1794 702 3.40 / 1342.17 1 3
7 13 149.08 32 14.07 523 235 3.63 / 1342.41 1 2
8 14 -0.12 180 14.34 286 738 4.37 / 1343.15 1 3
Average= 4.78 (KJ/cycle)

Cycle 279 GMT 8/ 8/2021 11:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 29 14.21 428 176 0.18 / 1334.65 2 2
2 12 1127.88 90 4.79 1642 708 0.88 / 1335.36 1 2
3 7 1140.12 20 8.62 1934 333 1.22 / 1335.69 2 2
4 13 1289.60 32 9.93 2173 690 1.91 / 1336.38 1 1
5 13 1222.88 32 10.90 2093 730 2.64 / 1337.11 1 2
6 13 1019.96 32 11.83 1811 686 3.32 / 1337.80 1 2
7 13 155.12 32 14.05 532 239 3.56 / 1338.04 1 2
8 14 -0.12 181 14.34 285 740 4.30 / 1338.78 2 2
Average= 4.78 (KJ/cycle)

Cycle 278 GMT 29/ 7/2021 15:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 30 14.27 442 189 0.19 / 1331.07 2 2
2 12 1123.84 90 5.90 1865 990 1.18 / 1332.06 1 2
3 7 1133.08 20 9.64 1953 377 1.56 / 1332.44 2 1
4 13 1037.68 32 11.64 1843 686 2.24 / 1333.13 1 2
5 13 832.36 32 12.41 1545 614 2.86 / 1333.74 1 2
6 14 -0.04 180 14.35 284 734 3.59 / 1334.47 1 2
Average= 4.78 (KJ/cycle)

Cycle 277 GMT 19/ 7/2021 20:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 30 14.27 425 182 0.18 / 1326.32 2 2
2 12 1104.96 4 11.19 1917 86 0.27 / 1326.41 1 2
3 12 1746.68 90 8.52 2810 2155 2.42 / 1328.56 1 2
4 7 1739.40 20 10.07 2826 569 2.99 / 1329.13 2 2
5 13 1070.56 32 12.81 1853 760 3.75 / 1329.89 1 1
6 13 168.12 32 14.07 559 252 4.00 / 1330.14 1 2
7 14 -0.04 180 14.38 286 740 4.74 / 1330.89 1 8
Average= 4.79 (KJ/cycle)

Cycle 276 GMT 18/ 7/2021 16:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 29 14.22 423 174 0.17 / 1321.90 1 2
2 12 1125.44 90 4.80 1668 721 0.90 / 1322.62 1 2
3 7 1137.40 20 8.88 1949 346 1.24 / 1322.97 2 2
4 13 1281.20 32 10.31 2164 714 1.96 / 1323.69 1 2
5 13 1189.52 32 11.15 2057 734 2.69 / 1324.42 1 2
6 13 987.28 32 12.01 1770 680 3.37 / 1325.10 1 1
7 13 259.68 32 13.87 693 308 3.68 / 1325.41 1 2
8 14 -0.20 180 14.33 285 735 4.41 / 1326.14 1 6
Average= 4.79 (KJ/cycle)

Cycle 275 GMT 8/ 7/2021 21: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 30 14.24 420 179 0.18 / 1317.52 2 2
2 3 971.44 -1 14.24 420 0 0.00 / 1317.52 2 2
3 3 1032.08 1 10.93 1840 20 0.20 / 1317.54 1 1
4 12 1147.48 91 4.79 1647 718 0.92 / 1318.26 1 2
5 7 1159.68 21 8.55 1971 354 1.27 / 1318.61 2 2
6 13 1315.04 32 9.97 2220 708 1.98 / 1319.32 1 2
7 13 1216.28 32 10.99 2091 735 2.71 / 1320.06 1 2
8 13 1025.88 32 11.87 1827 694 3.41 / 1320.75 1 2
9 13 163.60 32 14.00 548 246 3.65 / 1321.00 1 2
10 14 -0.12 180 14.32 285 735 4.39 / 1321.73 2 9
Average= 4.79 (KJ/cycle)

Cycle 274 GMT 29/ 6/2021 1:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 30 14.29 432 185 0.19 / 1313.75 1 2
2 12 1125.48 90 5.80 1866 974 1.16 / 1314.73 1 1
3 7 1135.36 20 9.63 1946 375 1.53 / 1315.10 1 2
4 13 1055.68 32 11.58 1857 688 2.22 / 1315.79 1 2
5 13 863.44 32 12.31 1598 629 2.85 / 1316.42 1 4
6 13 83.72 32 14.15 422 191 3.04 / 1316.61 1 2
7 14 -0.16 180 14.33 283 730 3.77 / 1317.34 2 6
Average= 4.79 (KJ/cycle)

Cycle 273 GMT 19/ 6/2021 6:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 30 14.22 427 182 0.18 / 1308.55 2 2
2 12 1098.44 4 11.07 1923 85 0.27 / 1308.64 1 2
3 12 1992.80 90 7.49 3153 2125 2.39 / 1310.76 1 1
4 7 1984.40 21 9.91 3199 666 3.06 / 1311.43 1 2
5 13 1328.24 32 12.50 2199 880 3.94 / 1312.31 1 2
6 13 621.36 32 13.48 1205 520 4.46 / 1312.83 1 2
7 14 -0.08 180 14.36 286 739 5.20 / 1313.57 1 5
Average= 4.79 (KJ/cycle)

Cycle 272 GMT 18/ 6/2021 1:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 30 14.21 434 185 0.19 / 1304.24 2 2
2 12 1120.48 90 4.80 1661 718 0.90 / 1304.96 1 2
3 7 1131.60 20 8.99 1948 350 1.25 / 1305.31 2 1
4 13 1288.16 32 10.51 2178 733 1.99 / 1306.04 1 2
5 13 1179.44 32 11.39 2030 740 2.73 / 1306.78 1 2
6 13 978.52 32 12.19 1757 685 3.41 / 1307.47 1 2
7 13 64.80 32 14.17 391 177 3.59 / 1307.64 1 2
8 14 -0.12 180 14.33 282 727 4.32 / 1308.37 2 3
Average= 4.79 (KJ/cycle)

Cycle 271 GMT 8/ 6/2021 6: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 30 14.23 415 177 0.18 / 1299.88 2 2
2 3 969.36 -1 14.23 415 0 0.00 / 1299.88 2 2
3 3 1029.36 1 10.73 1837 20 0.20 / 1299.90 1 2
4 12 1131.24 90 4.79 1653 713 0.91 / 1300.61 1 2
5 7 1144.20 21 8.71 1970 360 1.27 / 1300.97 2 2
6 13 1298.16 32 10.22 2194 718 1.99 / 1301.69 1 2
7 13 1201.28 32 11.24 2065 743 2.73 / 1302.43 1 1
8 13 1006.20 32 12.07 1793 693 3.42 / 1303.13 1 4
9 13 81.60 32 14.12 423 191 3.61 / 1303.32 1 2
10 14 -0.08 180 14.32 286 737 4.35 / 1304.06 2 3
Average= 4.79 (KJ/cycle)

Cycle 270 GMT 29/ 5/2021 10:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 30 14.31 419 180 0.18 / 1296.10 2 2
2 3 969.00 -1 14.31 419 0 0.00 / 1296.10 2 2
3 3 1038.16 1 10.69 1837 20 0.20 / 1296.12 1 1
4 12 1139.08 90 5.71 1875 964 1.16 / 1297.08 1 1
5 7 1148.48 21 9.60 1975 398 1.56 / 1297.48 1 2
6 13 1079.92 32 11.53 1897 700 2.26 / 1298.18 1 1
7 13 886.64 32 12.32 1615 637 2.90 / 1298.81 1 2
8 13 69.04 32 14.17 391 177 3.08 / 1298.99 2 2
9 14 -0.04 180 14.35 276 713 3.79 / 1299.70 2 6
Average= 4.80 (KJ/cycle)

Cycle 269 GMT 19/ 5/2021 15:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 30 14.25 418 179 0.18 / 1290.65 2 2
2 12 1107.48 4 10.76 1948 84 0.26 / 1290.74 1 1
3 12 1994.72 91 7.53 3137 2150 2.41 / 1292.89 1 1
4 7 1986.56 21 9.95 3190 667 3.08 / 1293.55 1 1
5 13 1529.16 32 12.24 2531 991 4.07 / 1294.54 1 1
6 13 578.08 32 13.52 1166 504 4.57 / 1295.05 1 2
7 13 27.52 32 14.25 324 148 4.72 / 1295.20 1 2
8 14 -0.08 180 14.38 278 720 5.44 / 1295.92 2 5
Average= 4.80 (KJ/cycle)

Cycle 268 GMT 18/ 5/2021 10:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 30 14.21 427 182 0.18 / 1286.33 2 2
2 12 1132.80 90 4.79 1637 706 0.89 / 1287.04 1 2
3 7 1144.72 20 9.07 1965 356 1.24 / 1287.39 2 1
4 13 1291.48 32 10.62 2188 744 1.99 / 1288.14 1 2
5 13 1180.48 32 11.55 2041 754 2.74 / 1288.89 1 2
6 13 986.04 32 12.32 1767 697 3.44 / 1289.59 1 3
7 13 62.08 32 14.17 384 174 3.61 / 1289.76 2 2
8 14 -0.08 180 14.35 276 713 4.33 / 1290.47 2 4
Average= 4.80 (KJ/cycle)

Cycle 267 GMT 8/ 5/2021 15:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 30 14.22 422 180 0.18 / 1281.98 2 2
2 12 1127.72 90 4.80 1673 723 0.90 / 1282.70 1 2
3 7 1139.28 20 8.76 1949 341 1.24 / 1283.05 2 2
4 13 1291.24 32 10.34 2174 719 1.96 / 1283.77 1 2
5 13 1187.20 32 11.40 2047 747 2.71 / 1284.51 1 2
6 13 993.52 32 12.26 1753 688 3.40 / 1285.20 1 2
7 13 122.20 33 14.05 483 224 3.62 / 1285.42 1 2
8 14 -0.20 181 14.32 280 726 4.35 / 1286.15 1 4
Average= 4.80 (KJ/cycle)

Cycle 266 GMT 28/ 4/2021 19:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 29 14.29 416 172 0.17 / 1278.15 2 2
2 3 1019.40 1 10.57 1800 19 0.19 / 1278.17 1 1
3 12 1133.68 91 6.03 1880 1032 1.22 / 1279.20 1 2
4 7 1143.96 21 9.77 1953 401 1.62 / 1279.60 2 2
5 13 1038.20 32 11.82 1832 693 2.32 / 1280.29 1 2
6 13 820.60 32 12.60 1532 618 2.93 / 1280.91 1 2
7 13 66.84 32 14.16 391 177 3.11 / 1281.09 1 2
8 14 -0.12 180 14.34 277 715 3.83 / 1281.80 2 7
Average= 4.80 (KJ/cycle)

Cycle 265 GMT 19/ 4/2021 0:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 30 14.20 419 178 0.18 / 1272.99 2 2
2 12 1094.36 4 10.76 1917 83 0.26 / 1273.08 1 1
3 12 1991.00 90 7.45 3152 2113 2.37 / 1275.19 1 2
4 7 1983.04 20 9.95 3188 634 3.01 / 1275.82 2 1
5 13 1328.32 32 12.54 2214 888 3.90 / 1276.71 1 2
6 13 636.24 32 13.46 1233 531 4.43 / 1277.24 1 2
7 14 -0.12 180 14.36 283 731 5.16 / 1277.97 2 2
Average= 4.80 (KJ/cycle)

Cycle 264 GMT 17/ 4/2021 20:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 30 14.19 412 175 0.18 / 1268.61 2 2
2 12 1106.72 91 4.79 1649 719 0.89 / 1269.33 1 2
3 7 1118.24 21 9.12 1934 370 1.26 / 1269.70 2 2
4 13 1264.36 32 10.77 2157 743 2.01 / 1270.44 1 2
5 13 1157.72 32 11.70 2000 749 2.76 / 1271.19 1 2
6 13 942.72 33 12.43 1706 700 3.46 / 1271.89 1 3
7 13 91.72 32 14.09 439 198 3.65 / 1272.09 1 2
8 14 -0.16 180 14.30 283 728 4.38 / 1272.82 2 7
Average= 4.80 (KJ/cycle)

Cycle 263 GMT 8/ 4/2021 0:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 30 14.18 419 178 0.18 / 1264.28 2 2
2 12 1113.00 90 4.79 1663 717 0.90 / 1265.00 1 2
3 7 1123.88 20 8.89 1922 342 1.24 / 1265.34 2 2
4 13 1266.72 33 10.39 2146 736 1.97 / 1266.08 1 2
5 13 1165.12 33 11.52 2004 762 2.73 / 1266.84 1 2
6 13 958.32 33 12.38 1701 695 3.43 / 1267.53 1 1
7 13 56.72 32 14.14 380 172 3.60 / 1267.71 2 2
8 14 0.12 181 14.29 281 727 4.33 / 1268.43 2 6
Average= 4.80 (KJ/cycle)

Cycle 262 GMT 29/ 3/2021 5:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 29 14.30 416 173 0.17 / 1260.62 2 2
2 12 1111.20 91 6.16 1863 1044 1.22 / 1261.66 1 2
3 7 1118.60 21 9.86 1922 398 1.61 / 1262.06 2 2
4 13 992.68 32 11.97 1767 677 2.29 / 1262.74 1 1
5 13 578.84 32 13.24 1182 501 2.79 / 1263.24 1 2
6 13 25.04 32 14.19 328 149 2.94 / 1263.39 1 2
7 14 -0.20 180 14.29 279 718 3.66 / 1264.10 2 9
Average= 4.81 (KJ/cycle)

Cycle 261 GMT 19/ 3/2021 10:35: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 30 14.23 418 178 0.18 / 1255.23 2 2
2 12 1108.92 4 10.66 1945 83 0.26 / 1255.31 1 1
3 12 1993.56 90 7.80 3153 2213 2.47 / 1257.52 1 1
4 7 1985.40 20 10.06 3173 638 3.11 / 1258.16 1 1
5 13 1300.16 32 12.62 2185 882 4.00 / 1259.04 1 2
6 13 583.52 33 13.53 1144 511 4.51 / 1259.55 1 2
7 13 22.68 33 14.25 328 154 4.66 / 1259.71 1 2
8 14 -0.12 181 14.34 284 737 5.40 / 1260.44 2 7
Average= 4.81 (KJ/cycle)

Cycle 260 GMT 18/ 3/2021 6: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 29 14.22 412 170 0.17 / 1250.79 2 2
2 3 1019.00 1 10.53 1821 19 0.19 / 1250.81 1 1
3 12 1126.92 91 4.80 1667 728 0.92 / 1251.53 1 2
4 7 1137.36 21 9.29 1975 385 1.30 / 1251.92 2 2
5 13 1285.52 32 11.13 2185 778 2.08 / 1252.70 1 2
6 13 1166.72 32 11.99 2023 776 2.86 / 1253.47 1 2
7 13 953.96 32 12.67 1694 687 3.54 / 1254.16 1 3
8 13 44.44 32 14.19 360 163 3.71 / 1254.32 1 2
9 14 -0.12 180 14.29 281 723 4.43 / 1255.05 2 7
Average= 4.81 (KJ/cycle)

Cycle 259 GMT 8/ 3/2021 10:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 29 14.22 409 169 0.17 / 1246.43 2 2
2 12 1113.36 90 4.80 1672 722 0.89 / 1247.15 1 2
3 7 1125.52 20 9.02 1935 349 1.24 / 1247.50 2 2
4 13 1276.00 32 10.68 2176 744 1.98 / 1248.24 1 2
5 13 1167.32 32 11.74 2019 758 2.74 / 1249.00 1 2
6 13 955.80 32 12.54 1704 684 3.43 / 1249.68 1 4
7 13 106.88 32 14.08 456 205 3.63 / 1249.89 1 2
8 14 -0.12 181 14.29 281 727 4.36 / 1250.62 2 5
Average= 4.81 (KJ/cycle)

Cycle 258 GMT 26/ 2/2021 15: 9: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 30 14.24 417 178 0.18 / 1242.59 2 2
2 3 972.72 -1 14.24 417 0 0.00 / 1242.59 2 2
3 3 1037.80 1 10.46 1844 19 0.20 / 1242.61 1 2
4 12 1140.24 91 6.06 1874 1033 1.23 / 1243.64 1 2
5 7 1147.16 21 9.89 1961 407 1.64 / 1244.05 2 2
6 13 1043.24 32 11.98 1840 705 2.34 / 1244.75 1 2
7 13 832.20 32 12.71 1549 630 2.97 / 1245.38 1 2
8 13 32.64 32 14.18 340 154 3.13 / 1245.54 1 2
9 14 -0.16 180 14.28 281 722 3.85 / 1246.26 2 6
Average= 4.81 (KJ/cycle)

Cycle 257 GMT 16/ 2/2021 20:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 30 14.19 417 178 0.18 / 1237.24 2 2
2 12 1090.76 4 10.61 1923 82 0.26 / 1237.32 1 2
3 12 1987.96 90 7.67 3158 2180 2.44 / 1239.50 1 1
4 7 1980.32 20 10.06 3193 642 3.08 / 1240.14 1 1
5 13 1313.32 32 12.60 2196 885 3.97 / 1241.03 1 3
6 13 604.80 32 13.51 1175 508 4.47 / 1241.54 1 2
7 13 26.80 32 14.24 329 150 4.62 / 1241.69 1 2
8 14 -0.12 180 14.33 280 722 5.35 / 1242.41 2 8
Average= 4.82 (KJ/cycle)

Cycle 256 GMT 15/ 2/2021 15:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 30 14.21 416 177 0.18 / 1232.81 2 2
2 3 967.60 -1 14.21 416 0 0.00 / 1232.81 2 2
3 12 1143.56 91 4.79 1641 715 0.89 / 1233.53 1 2
4 7 1154.80 21 9.18 1988 383 1.28 / 1233.91 2 2
5 13 1296.44 32 11.05 2200 778 2.05 / 1234.69 1 1
6 13 1178.08 32 11.98 2033 779 2.83 / 1235.47 1 2
7 13 969.00 32 12.63 1726 698 3.53 / 1236.16 1 4
8 13 51.52 32 14.15 374 169 3.70 / 1236.33 1 2
9 14 -0.16 180 14.29 283 728 4.43 / 1237.06 2 6
Average= 4.81 (KJ/cycle)

Cycle 255 GMT 5/ 2/2021 20:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 30 14.20 426 181 0.18 / 1228.45 2 2
2 12 1122.96 90 4.80 1673 723 0.90 / 1229.17 1 2
3 7 1136.72 20 9.08 1951 354 1.26 / 1229.53 2 2
4 13 1274.76 32 10.97 2161 759 2.02 / 1230.28 1 2
5 13 1161.24 32 11.91 2017 769 2.79 / 1231.05 1 2
6 13 949.00 32 12.64 1689 683 3.47 / 1231.74 1 3
7 13 42.80 33 14.17 354 166 3.63 / 1231.90 1 2
8 14 -0.12 181 14.28 283 731 4.37 / 1232.63 1 9
Average= 4.81 (KJ/cycle)

Cycle 254 GMT 27/ 1/2021 0:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 30 14.24 412 176 0.18 / 1224.84 2 2
2 12 1126.08 90 6.27 1876 1059 1.23 / 1225.90 1 2
3 7 1136.76 20 10.02 1959 393 1.63 / 1226.29 2 2
4 13 1029.04 33 12.04 1822 724 2.35 / 1227.01 1 2
5 13 604.00 33 13.23 1212 529 2.88 / 1227.54 1 2
6 14 -0.08 181 14.30 280 725 3.61 / 1228.27 1 3
Average= 4.82 (KJ/cycle)

Cycle 253 GMT 17/ 1/2021 6:11: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 29 14.17 420 173 0.17 / 1219.62 2 2
2 12 1120.44 4 10.57 1961 83 0.26 / 1219.70 1 1
3 12 1994.64 91 7.83 3188 2272 2.53 / 1221.97 1 2
4 7 1986.24 21 10.19 3204 686 3.21 / 1222.66 2 1
5 13 1295.36 32 12.66 2186 886 4.10 / 1223.54 1 2
6 13 387.36 32 13.77 885 390 4.49 / 1223.93 1 2
7 14 -0.12 180 14.36 282 729 5.22 / 1224.66 1 5
Average= 4.82 (KJ/cycle)

Cycle 252 GMT 16/ 1/2021 1:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 31 14.20 426 188 0.19 / 1215.20 2 2
2 3 961.68 -1 14.20 426 0 0.00 / 1215.20 2 2
3 3 1028.20 1 10.09 1809 18 0.21 / 1215.22 1 1
4 12 1133.32 90 4.79 1652 712 0.92 / 1215.93 1 2
5 7 1145.96 20 9.38 1955 367 1.28 / 1216.30 2 2
6 13 1293.80 32 11.23 2200 791 2.08 / 1217.09 1 2
7 13 1169.92 32 12.15 2022 786 2.86 / 1217.88 1 2
8 13 958.28 32 12.75 1711 698 3.56 / 1218.57 1 2
9 13 20.44 32 14.21 319 145 3.70 / 1218.72 1 2
10 14 -0.04 181 14.30 281 727 4.43 / 1219.45 2 5
Average= 4.82 (KJ/cycle)

Cycle 251 GMT 6/ 1/2021 6: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 30 14.19 430 183 0.18 / 1210.78 2 2
2 3 1028.52 1 10.39 1828 19 0.20 / 1210.80 1 1
3 3 1026.08 1 9.71 1801 17 0.22 / 1210.82 1 1
4 12 1146.60 91 4.80 1680 734 0.95 / 1211.55 1 2
5 7 1158.08 21 9.20 1990 384 1.34 / 1211.94 2 2
6 13 1303.56 32 11.13 2207 786 2.12 / 1212.72 1 1
7 13 1181.72 32 12.07 2043 789 2.91 / 1213.51 1 2
8 13 770.80 32 13.06 1463 611 3.52 / 1214.13 1 2
9 13 53.64 32 14.15 372 168 3.69 / 1214.29 1 2
10 14 -0.16 180 14.29 280 720 4.41 / 1215.01 2 7
Average= 4.82 (KJ/cycle)

Cycle 250 GMT 27/12/2020 10:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 30 14.23 420 179 0.18 / 1207.24 2 2
2 12 1118.76 90 6.20 1859 1037 1.22 / 1208.28 1 2
3 7 1128.44 20 10.02 1939 389 1.61 / 1208.67 2 2
4 13 1014.92 32 12.13 1807 701 2.31 / 1209.37 1 2
5 13 586.44 32 13.29 1186 504 2.81 / 1209.87 1 2
6 14 -0.16 180 14.28 283 727 3.54 / 1210.60 1 3
Average= 4.82 (KJ/cycle)

Cycle 249 GMT 17/12/2020 15:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 29 14.19 417 172 0.17 / 1202.13 2 2
2 12 1123.20 4 10.45 1962 82 0.25 / 1202.21 1 1
3 12 1894.76 90 8.04 3036 2197 2.45 / 1204.41 1 2
4 7 1887.36 20 10.20 3069 626 3.08 / 1205.04 2 2
5 13 1195.68 33 12.74 2028 853 3.93 / 1205.89 1 3
6 13 460.56 32 13.67 989 433 4.36 / 1206.32 1 2
7 14 -0.04 181 14.33 285 739 5.10 / 1207.06 2 3
Average= 4.83 (KJ/cycle)

Cycle 248 GMT 16/12/2020 11:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 30 14.12 419 177 0.18 / 1197.70 2 2
2 12 1118.24 90 4.80 1674 723 0.90 / 1198.42 1 2
3 7 1130.72 20 9.34 1947 364 1.26 / 1198.79 2 2
4 13 1280.72 32 11.21 2180 782 2.05 / 1199.57 1 2
5 13 1163.88 32 12.14 2021 785 2.83 / 1200.35 1 2
6 13 945.56 32 12.75 1697 692 3.52 / 1201.05 1 2
7 13 74.04 32 14.12 406 183 3.71 / 1201.23 2 2
8 14 -0.12 181 14.29 283 732 4.44 / 1201.96 2 6
Average= 4.83 (KJ/cycle)

Cycle 247 GMT 6/12/2020 16: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 30 14.19 413 176 0.18 / 1193.25 2 2
2 12 1123.32 90 4.84 1737 757 0.93 / 1194.00 1 2
3 7 1135.24 20 9.36 1951 365 1.30 / 1194.37 2 2
4 13 1276.44 32 11.18 2176 778 2.08 / 1195.15 1 2
5 13 1161.60 32 12.11 2014 780 2.86 / 1195.93 1 2
6 13 948.60 32 12.70 1720 699 3.56 / 1196.63 1 2
7 13 34.32 33 14.18 342 160 3.72 / 1196.79 2 2
8 14 -0.08 181 14.28 284 734 4.45 / 1197.52 2 10
Average= 4.83 (KJ/cycle)

Cycle 246 GMT 26/11/2020 20:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 29 14.17 421 173 0.17 / 1189.50 2 2
2 12 1134.04 91 6.37 1897 1100 1.27 / 1190.60 1 1
3 7 1142.88 20 10.25 1960 402 1.67 / 1191.00 1 2
4 13 1035.00 32 12.28 1831 720 2.39 / 1191.72 1 3
5 13 816.20 33 12.92 1493 637 3.03 / 1192.35 1 2
6 14 0.00 180 14.29 279 718 3.75 / 1193.07 1 5
Average= 4.83 (KJ/cycle)

Cycle 245 GMT 17/11/2020 2: 5: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 29 14.18 419 172 0.17 / 1184.24 2 2
2 12 1116.76 4 10.48 1950 82 0.25 / 1184.33 1 1
3 12 1986.28 90 7.91 3167 2255 2.51 / 1186.58 1 2
4 7 1977.72 20 10.22 3177 649 3.16 / 1187.23 2 2
5 13 1284.72 32 12.72 2138 870 4.03 / 1188.10 1 3
6 13 567.36 32 13.57 1120 486 4.51 / 1188.59 1 3
7 14 -0.08 181 14.34 284 737 5.25 / 1189.32 2 4
Average= 4.83 (KJ/cycle)

Cycle 244 GMT 15/11/2020 21:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 30 14.12 423 179 0.18 / 1179.79 2 2
2 12 1108.36 91 4.81 1708 748 0.93 / 1180.54 1 2
3 7 1119.80 21 9.57 1924 387 1.31 / 1180.93 2 2
4 13 1259.52 32 11.42 2159 789 2.10 / 1181.72 1 1
5 13 1136.44 32 12.27 1978 777 2.88 / 1182.49 1 2
6 13 917.96 33 12.81 1662 703 3.58 / 1183.20 1 2
7 13 38.16 32 14.18 344 156 3.74 / 1183.35 2 2
8 14 -0.20 180 14.28 280 720 4.46 / 1184.07 2 5
Average= 4.83 (KJ/cycle)

Cycle 243 GMT 6/11/2020 2:13: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 29 14.15 426 175 0.17 / 1175.43 2 2
2 12 1123.56 91 4.84 1746 769 0.94 / 1176.20 1 2
3 7 1134.84 21 9.54 1958 392 1.34 / 1176.59 2 2
4 13 1273.12 32 11.37 2171 790 2.13 / 1177.38 1 2
5 13 1145.80 32 12.20 2002 782 2.91 / 1178.16 1 2
6 13 716.12 32 13.15 1389 584 3.49 / 1178.75 1 3
7 13 19.52 32 14.20 317 144 3.64 / 1178.89 2 2
8 14 0.04 180 14.29 281 723 4.36 / 1179.61 2 11
Average= 4.83 (KJ/cycle)

Cycle 242 GMT 27/10/2020 6:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 29 14.21 421 173 0.17 / 1171.81 2 2
2 12 1118.04 90 6.64 1886 1127 1.30 / 1172.93 1 2
3 7 1126.16 21 10.25 1942 418 1.72 / 1173.35 2 2
4 13 980.76 32 12.42 1744 693 2.41 / 1174.05 1 3
5 13 543.52 32 13.38 1124 481 2.89 / 1174.53 1 2
6 14 -0.16 180 14.27 284 729 3.62 / 1175.26 2 5
Average= 4.84 (KJ/cycle)

Cycle 241 GMT 17/10/2020 12:10: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 29 14.17 435 179 0.18 / 1166.62 2 2
2 12 1119.20 4 10.58 1951 83 0.26 / 1166.70 1 1
3 12 1979.96 91 7.99 3156 2295 2.56 / 1169.00 1 2
4 7 1971.32 20 10.24 3164 648 3.20 / 1169.65 2 1
5 13 1270.24 32 12.72 2142 872 4.08 / 1170.52 1 4
6 13 351.12 32 13.79 829 366 4.44 / 1170.88 1 2
7 14 -0.08 180 14.30 291 749 5.19 / 1171.63 2 5
Average= 4.84 (KJ/cycle)

Cycle 240 GMT 16/10/2020 7:31:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 29 14.11 438 179 0.18 / 1162.31 2 2
2 12 1106.00 90 4.82 1735 753 0.93 / 1163.07 1 2
3 7 1117.48 20 9.65 1927 372 1.30 / 1163.44 2 2
4 13 1253.68 32 11.60 2143 795 2.10 / 1164.23 1 2
5 13 1128.12 32 12.36 1961 776 2.87 / 1165.01 1 2
6 13 691.84 32 13.26 1308 555 3.43 / 1165.56 1 2
7 13 14.20 32 14.19 313 142 3.57 / 1165.71 1 2
8 14 -0.08 180 14.26 287 737 4.31 / 1166.44 2 8
Average= 4.84 (KJ/cycle)

Cycle 239 GMT 6/10/2020 12:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 29 14.12 429 176 0.18 / 1158.25 2 2
2 12 1106.60 91 4.95 1763 794 0.97 / 1159.04 1 2
3 7 1119.04 21 9.72 1939 396 1.37 / 1159.44 2 1
4 13 1240.64 32 11.61 2115 786 2.15 / 1160.22 1 2
5 13 1095.60 32 12.43 1893 753 2.90 / 1160.98 1 4
6 13 444.48 32 13.57 965 419 3.32 / 1161.40 1 2
7 14 -0.08 180 14.25 288 739 4.06 / 1162.13 2 4
Average= 4.84 (KJ/cycle)

Cycle 238 GMT 26/ 9/2020 16:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 29 14.19 426 175 0.18 / 1154.69 2 2
2 12 1123.92 91 6.62 1878 1131 1.31 / 1155.83 1 1
3 7 1133.04 21 10.30 1955 423 1.73 / 1156.25 1 2
4 13 987.12 33 12.40 1771 725 2.45 / 1156.97 1 2
5 13 340.52 32 13.69 814 357 2.81 / 1157.33 1 1
6 14 -0.16 181 14.23 288 742 3.55 / 1158.07 2 5
Average= 4.85 (KJ/cycle)

Cycle 237 GMT 16/ 9/2020 22: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 29 14.15 429 176 0.18 / 1149.53 2 2
2 12 1108.20 4 10.56 1943 82 0.26 / 1149.61 1 1
3 12 1990.20 90 8.14 3145 2304 2.56 / 1151.92 1 1
4 7 1981.44 20 10.29 3181 655 3.22 / 1152.57 1 2
5 13 1255.12 32 12.76 2107 860 4.08 / 1153.43 1 3
6 13 308.48 32 13.83 773 342 4.42 / 1153.77 1 2
7 14 0.00 181 14.31 288 746 5.17 / 1154.52 1 4
Average= 4.85 (KJ/cycle)

Cycle 236 GMT 15/ 9/2020 17:37: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 29 14.11 435 178 0.18 / 1145.37 2 2
2 12 1102.24 91 4.89 1760 783 0.96 / 1146.16 1 2
3 7 1114.32 20 9.80 1927 378 1.34 / 1146.53 2 2
4 13 1235.64 33 11.73 2108 816 2.15 / 1147.35 1 2
5 13 1069.92 32 12.57 1870 752 2.91 / 1148.10 1 4
6 13 628.04 32 13.38 1205 516 3.42 / 1148.62 1 2
7 14 0.00 180 14.27 287 737 4.16 / 1149.35 2 2
Average= 4.85 (KJ/cycle)

Cycle 235 GMT 5/ 9/2020 22:22: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 29 14.14 428 176 0.18 / 1141.36 2 2
2 12 1113.64 91 5.08 1778 822 1.00 / 1142.18 1 2
3 7 1124.24 20 9.84 1950 384 1.38 / 1142.57 2 2
4 13 1204.36 32 11.82 2075 785 2.17 / 1143.35 1 2
5 13 1035.36 32 12.58 1830 737 2.90 / 1144.09 1 3
6 13 346.56 32 13.71 826 362 3.27 / 1144.45 1 2
7 14 -0.12 181 14.25 288 743 4.01 / 1145.19 1 4
Average= 4.85 (KJ/cycle)

Cycle 234 GMT 27/ 8/2020 3:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 29 14.14 438 180 0.18 / 1137.67 2 2
2 12 1120.04 91 6.92 1896 1194 1.37 / 1138.86 1 2
3 7 1126.88 21 10.45 1944 427 1.80 / 1139.29 2 2
4 13 973.20 32 12.61 1726 696 2.50 / 1139.99 1 2
5 13 519.28 32 13.45 1091 470 2.97 / 1140.45 1 2
6 14 -0.04 180 14.26 285 732 3.70 / 1141.19 2 7
Average= 4.86 (KJ/cycle)

Cycle 233 GMT 17/ 8/2020 8:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 29 14.13 441 181 0.18 / 1132.58 2 2
2 12 1110.04 4 10.94 1915 84 0.26 / 1132.67 1 1
3 12 1980.60 91 8.31 3157 2387 2.65 / 1135.05 1 1
4 7 1971.12 21 10.32 3160 685 3.34 / 1135.74 1 2
5 13 1054.44 32 13.01 1826 760 4.10 / 1136.50 1 2
6 13 177.36 32 14.00 567 254 4.35 / 1136.75 1 1
7 14 -0.12 180 14.32 285 735 5.09 / 1137.49 1 10
Average= 4.86 (KJ/cycle)

Cycle 232 GMT 16/ 8/2020 4: 9: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 29 14.13 434 178 0.18 / 1128.56 2 2
2 12 1119.12 90 5.05 1810 823 1.00 / 1129.38 1 2
3 7 1129.40 20 9.99 1945 389 1.39 / 1129.77 2 2
4 13 1203.36 32 12.00 2076 797 2.19 / 1130.57 1 2
5 13 1029.88 32 12.70 1825 742 2.93 / 1131.31 1 2
6 13 337.20 32 13.75 806 355 3.28 / 1131.67 1 2
7 14 0.24 180 14.26 287 737 4.02 / 1132.40 1 6
Average= 4.86 (KJ/cycle)

Cycle 231 GMT 6/ 8/2020 9: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 29 14.13 427 175 0.17 / 1124.78 2 2
2 12 1098.12 90 5.46 1794 882 1.06 / 1125.66 1 2
3 7 1108.88 20 10.11 1917 388 1.44 / 1126.04 2 1
4 13 1083.80 32 12.19 1912 746 2.19 / 1126.79 1 2
5 13 891.80 32 12.87 1629 671 2.86 / 1127.46 1 3
6 13 63.92 33 14.10 391 182 3.04 / 1127.64 1 2
7 14 -0.28 181 14.25 287 740 3.78 / 1128.38 2 8
Average= 4.86 (KJ/cycle)

Cycle 230 GMT 27/ 7/2020 14:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 30 14.12 436 185 0.18 / 1121.19 2 2
2 3 970.08 -1 14.12 436 0 0.00 / 1121.19 2 2
3 3 1034.52 1 10.72 1826 20 0.20 / 1121.21 1 1
4 12 1139.64 90 6.99 1908 1200 1.40 / 1122.41 1 2
5 7 1146.24 20 10.46 1980 414 1.82 / 1122.82 2 2
6 13 975.76 32 12.66 1748 708 2.53 / 1123.53 1 2
7 13 294.40 32 13.76 748 329 2.86 / 1123.86 1 2
8 14 0.00 180 14.25 288 739 3.60 / 1124.60 2 6
Average= 4.87 (KJ/cycle)

Cycle 229 GMT 17/ 7/2020 19:43: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 30 14.12 436 185 0.18 / 1115.91 1 2
2 3 965.76 -1 14.12 436 0 0.00 / 1115.91 1 2
3 3 1029.96 1 10.25 1803 18 0.20 / 1115.93 1 1
4 12 1143.92 4 10.79 1988 86 0.29 / 1116.02 1 1
5 12 1975.32 90 8.40 3148 2380 2.67 / 1118.40 1 2
6 7 1966.80 20 10.35 3175 657 3.33 / 1119.05 2 1
7 13 1253.00 32 12.80 2111 865 4.19 / 1119.92 1 3
8 13 300.72 32 13.85 756 335 4.53 / 1120.25 1 2
9 14 -0.08 181 14.31 290 751 5.28 / 1121.01 2 5
Average= 4.87 (KJ/cycle)

Cycle 228 GMT 16/ 7/2020 15:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 29 14.15 431 177 0.18 / 1112.05 2 2
2 12 1100.28 90 5.63 1815 920 1.10 / 1112.97 1 1
3 7 1111.60 20 10.21 1918 392 1.49 / 1113.36 1 1
4 13 1049.12 32 12.40 1860 738 2.23 / 1114.10 1 2
5 13 850.80 32 13.02 1537 640 2.87 / 1114.74 1 3
6 13 159.20 32 13.98 542 242 3.11 / 1114.98 1 2
7 14 0.04 181 14.26 289 746 3.85 / 1115.73 2 8
Average= 4.87 (KJ/cycle)

Cycle 227 GMT 6/ 7/2020 20:37:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 30 14.10 437 185 0.18 / 1108.19 2 2
2 3 970.40 -1 14.10 437 0 0.00 / 1108.19 2 2
3 3 1035.12 1 10.35 1847 19 0.20 / 1108.20 1 1
4 12 1143.40 90 5.51 1854 919 1.12 / 1109.12 1 1
5 7 1152.56 21 10.21 1987 426 1.55 / 1109.55 1 2
6 13 1094.20 32 12.38 1924 762 2.31 / 1110.31 1 2
7 13 892.40 32 12.96 1622 673 2.98 / 1110.99 1 2
8 13 33.80 32 14.16 342 155 3.14 / 1111.14 1 2
9 14 0.00 180 14.30 285 734 3.87 / 1111.87 2 6
Average= 4.88 (KJ/cycle)

Cycle 226 GMT 27/ 6/2020 1:54: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 29 14.14 442 181 0.18 / 1104.57 2 2
2 12 1118.24 91 7.29 1899 1260 1.44 / 1105.83 1 1
3 7 1124.04 20 10.70 1945 416 1.86 / 1106.25 1 2
4 13 949.36 32 12.74 1722 702 2.56 / 1106.95 1 5
5 13 267.68 32 13.81 705 312 2.87 / 1107.26 1 2
6 14 -0.24 180 14.25 289 741 3.61 / 1108.00 1 4
Average= 4.88 (KJ/cycle)

Cycle 225 GMT 17/ 6/2020 7:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 30 14.12 438 186 0.19 / 1099.31 2 2
2 12 1101.92 4 10.86 1934 84 0.27 / 1099.39 1 2
3 12 1972.76 91 8.35 3135 2382 2.65 / 1101.77 1 2
4 7 1964.36 21 10.39 3153 688 3.34 / 1102.46 2 1
5 13 1250.80 32 12.84 2100 863 4.20 / 1103.32 1 3
6 13 269.00 32 13.87 713 316 4.52 / 1103.64 1 2
7 14 0.00 180 14.32 291 750 5.27 / 1104.39 2 10
Average= 4.89 (KJ/cycle)

Cycle 224 GMT 16/ 6/2020 2:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 30 14.13 421 178 0.18 / 1095.66 2 2
2 12 1106.84 91 5.67 1823 941 1.12 / 1096.61 1 2
3 7 1115.76 21 10.34 1935 420 1.54 / 1097.03 2 2
4 13 1024.08 32 12.55 1812 728 2.27 / 1097.75 1 2
5 13 813.80 32 13.10 1506 631 2.90 / 1098.38 1 3
6 14 -0.20 180 14.28 286 735 3.63 / 1099.12 1 3
Average= 4.88 (KJ/cycle)

Cycle 223 GMT 6/ 6/2020 8:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 30 14.12 433 183 0.18 / 1092.00 2 2
2 12 1105.84 90 6.12 1833 1010 1.19 / 1093.01 1 2
3 7 1114.20 20 10.46 1932 404 1.60 / 1093.41 2 2
4 13 1005.60 32 12.60 1803 727 2.32 / 1094.14 1 2
5 13 787.76 32 13.13 1472 618 2.94 / 1094.76 1 2
6 14 -0.12 180 14.28 284 730 3.67 / 1095.49 2 4
Average= 4.89 (KJ/cycle)

Cycle 222 GMT 27/ 5/2020 14: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 29 14.21 418 172 0.17 / 1088.42 2 2
2 12 1124.12 90 7.73 1920 1336 1.51 / 1089.76 1 2
3 7 1130.60 20 10.75 1960 421 1.93 / 1090.18 2 1
4 13 938.72 32 12.86 1705 702 2.63 / 1090.88 1 2
5 13 104.84 32 14.06 458 206 2.84 / 1091.09 1 2
6 14 -0.20 180 14.30 283 728 3.57 / 1091.81 2 6
Average= 4.90 (KJ/cycle)

Cycle 221 GMT 17/ 5/2020 19:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 30 14.15 427 181 0.18 / 1083.26 2 2
2 12 1104.00 4 11.12 1921 85 0.27 / 1083.34 1 2
3 12 1989.80 91 8.84 3153 2536 2.80 / 1085.88 1 1
4 7 1980.52 20 10.44 3185 665 3.47 / 1086.54 1 2
5 13 1054.80 32 13.05 1842 769 4.24 / 1087.31 1 4
6 13 92.56 32 14.15 440 199 4.44 / 1087.51 1 2
7 14 -0.08 180 14.38 285 738 5.17 / 1088.25 2 4
Average= 4.90 (KJ/cycle)

Cycle 220 GMT 16/ 5/2020 14:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 29 14.14 435 178 0.18 / 1079.52 2 2
2 12 1126.80 90 6.07 1865 1019 1.20 / 1080.54 1 2
3 7 1135.20 20 10.50 1969 413 1.61 / 1080.96 2 1
4 13 1027.80 32 12.69 1839 747 2.36 / 1081.70 1 2
5 13 810.44 32 13.19 1496 631 2.99 / 1082.34 1 3
6 14 0.00 181 14.32 285 739 3.73 / 1083.07 1 4
Average= 4.90 (KJ/cycle)

Cycle 219 GMT 6/ 5/2020 20:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 29 14.13 417 171 0.17 / 1075.85 2 2
2 12 1115.20 90 6.70 1852 1117 1.29 / 1076.97 1 1
3 7 1122.24 20 10.67 1944 415 1.70 / 1077.38 1 2
4 13 975.48 39 12.70 1729 856 2.56 / 1078.24 1 5
5 13 261.68 39 13.81 695 374 2.93 / 1078.61 1 2
6 14 -0.04 180 14.27 285 732 3.67 / 1079.35 1 5
Average= 4.91 (KJ/cycle)

Cycle 218 GMT 27/ 4/2020 2: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 29 14.22 421 174 0.17 / 1072.06 2 2
2 12 1128.00 91 8.14 1920 1422 1.60 / 1073.48 1 1
3 7 1132.32 21 10.89 1963 449 2.04 / 1073.93 1 2
4 13 928.40 39 12.85 1678 841 2.89 / 1074.77 1 2
5 13 27.20 39 14.22 327 181 3.07 / 1074.95 1 2
6 14 -0.04 180 14.31 282 726 3.79 / 1075.68 2 7
Average= 4.91 (KJ/cycle)

Cycle 217 GMT 17/ 4/2020 7:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 30 14.17 431 183 0.18 / 1066.74 2 2
2 12 1107.76 4 11.15 1944 87 0.27 / 1066.82 1 1
3 12 1964.48 90 9.09 3117 2550 2.82 / 1069.37 1 2
4 7 1954.40 20 10.42 3165 660 3.48 / 1070.03 2 2
5 13 971.88 39 13.06 1721 877 4.36 / 1070.91 1 2
6 13 78.00 40 14.15 419 237 4.59 / 1071.15 1 2
7 14 -0.16 181 14.36 285 741 5.33 / 1071.89 2 5
Average= 4.92 (KJ/cycle)

Cycle 216 GMT 16/ 4/2020 3:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 29 14.15 428 176 0.18 / 1063.15 2 2
2 12 1121.64 90 6.91 1871 1164 1.34 / 1064.32 1 1
3 7 1129.80 20 10.76 1960 422 1.76 / 1064.74 1 2
4 13 970.76 39 12.77 1740 867 2.63 / 1065.61 1 2
5 13 71.36 39 14.12 403 222 2.85 / 1065.83 1 2
6 14 0.20 181 14.32 280 726 3.58 / 1066.55 1 6
Average= 4.91 (KJ/cycle)

Cycle 215 GMT 6/ 4/2020 8:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 30 14.22 413 176 0.18 / 1059.45 2 2
2 3 962.28 -1 14.22 413 0 0.00 / 1059.45 2 2
3 3 1027.88 1 11.02 1829 20 0.20 / 1059.47 1 2
4 12 1136.68 90 7.23 1889 1229 1.43 / 1060.70 1 2
5 7 1143.60 20 10.88 1973 429 1.85 / 1061.13 2 2
6 13 974.16 39 12.88 1728 868 2.72 / 1061.99 1 3
7 13 117.20 39 14.07 472 259 2.98 / 1062.25 1 2
8 14 -0.28 180 14.33 281 725 3.71 / 1062.98 2 7
Average= 4.92 (KJ/cycle)

Cycle 214 GMT 27/ 3/2020 14:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 29 14.25 419 173 0.17 / 1055.73 2 2
2 12 1112.04 90 8.85 1902 1515 1.69 / 1057.25 1 2
3 7 1114.20 20 11.06 1937 428 2.12 / 1057.67 2 1
4 13 687.60 39 13.32 1327 689 2.81 / 1058.36 1 2
5 13 29.44 39 14.26 331 184 2.99 / 1058.55 1 2
6 14 -0.08 180 14.36 280 724 3.71 / 1059.27 1 7
Average= 4.93 (KJ/cycle)

Cycle 213 GMT 17/ 3/2020 20:20: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 30 14.20 431 184 0.18 / 1050.26 2 2
2 12 1090.40 4 11.45 1906 87 0.27 / 1050.35 1 2
3 12 1962.64 91 9.55 3134 2724 2.99 / 1053.07 1 2
4 7 1952.16 21 10.59 3150 701 3.70 / 1053.77 2 2
5 13 937.16 39 13.14 1669 855 4.55 / 1054.63 1 2
6 13 52.32 39 14.27 368 205 4.76 / 1054.83 2 2
7 14 -0.04 180 14.42 280 727 5.48 / 1055.56 1 9
Average= 4.93 (KJ/cycle)

Cycle 212 GMT 16/ 3/2020 16:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 30 14.20 431 184 0.18 / 1046.55 2 2
2 12 1108.44 90 7.93 1856 1325 1.51 / 1047.87 1 2
3 7 1115.08 20 11.03 1936 427 1.94 / 1048.30 2 2
4 13 919.28 39 13.03 1653 840 2.78 / 1049.14 1 4
5 13 62.56 39 14.20 387 214 2.99 / 1049.35 2 2
6 14 -0.04 180 14.36 280 724 3.71 / 1050.08 1 8
Average= 4.93 (KJ/cycle)

Cycle 211 GMT 6/ 3/2020 22: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 30 14.17 421 179 0.18 / 1042.91 2 2
2 12 1104.08 90 8.72 1866 1464 1.64 / 1044.37 1 2
3 7 1108.80 20 11.17 1934 432 2.08 / 1044.80 2 2
4 13 887.72 39 13.13 1617 828 2.90 / 1045.63 1 3
5 14 -0.20 181 14.38 281 731 3.63 / 1046.36 2 4
Average= 4.94 (KJ/cycle)

Cycle 210 GMT 26/ 2/2020 4: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 29 14.22 421 174 0.17 / 1038.40 2 2
2 3 967.72 -1 14.22 421 0 0.00 / 1038.40 2 2
3 3 1029.84 1 12.05 1849 22 0.20 / 1038.42 1 2
4 12 1157.68 5 4.92 1802 44 0.24 / 1038.47 1 2
5 12 1212.60 91 9.28 2055 1735 1.98 / 1040.20 1 2
6 12 1213.12 64 10.15 2048 1330 3.31 / 1041.53 1 2
7 7 1198.24 20 11.00 2040 449 3.75 / 1041.98 2 2
8 14 -0.08 181 14.28 289 747 4.50 / 1042.73 2 4
Average= 4.94 (KJ/cycle)

Cycle 209 GMT 16/ 2/2020 10: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 30 14.16 439 186 0.19 / 1031.77 2 2
2 12 1117.36 5 11.58 1977 114 0.30 / 1031.89 1 1
3 12 1929.44 90 9.97 3098 2780 3.08 / 1034.67 1 2
4 12 1922.48 64 9.99 3075 1966 5.05 / 1036.63 1 2
5 7 1907.00 21 10.72 3060 689 5.74 / 1037.32 2 1
6 13 8.32 39 14.26 303 169 5.90 / 1037.49 1 2
7 14 0.04 180 14.34 285 736 6.64 / 1038.23 2 12
Average= 4.94 (KJ/cycle)

Cycle 208 GMT 15/ 2/2020 6:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 30 14.16 447 190 0.19 / 1027.46 2 2
2 12 1123.12 5 4.84 1455 35 0.23 / 1027.50 1 2
3 12 1207.28 90 8.58 2030 1568 1.79 / 1029.06 1 2
4 12 1211.92 64 10.02 2048 1313 3.11 / 1030.38 1 2
5 7 1200.52 21 10.91 2056 471 3.58 / 1030.85 2 2
6 14 -0.12 180 14.27 287 737 4.31 / 1031.59 2 5
Average= 4.94 (KJ/cycle)

Cycle 207 GMT 5/ 2/2020 12:33: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 30 14.19 432 184 0.18 / 1023.06 1 2
2 12 1101.52 5 4.87 1586 39 0.22 / 1023.09 1 2
3 12 1213.64 90 8.97 2054 1658 1.88 / 1024.75 1 1
4 12 1216.12 64 10.08 2056 1326 3.21 / 1026.08 1 2
5 7 1202.84 20 10.92 2066 451 3.66 / 1026.53 2 2
6 14 -0.08 180 14.27 289 742 4.40 / 1027.27 2 5
Average= 4.94 (KJ/cycle)

Cycle 206 GMT 26/ 1/2020 18:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 28 14.23 428 171 0.17 / 1018.49 2 2
2 3 1028.88 1 12.12 1868 23 0.19 / 1018.52 1 1
3 12 1137.28 5 4.96 1952 48 0.24 / 1018.56 1 2
4 12 1204.96 90 9.55 2052 1764 2.01 / 1020.33 1 2
5 12 1207.40 64 10.18 2052 1337 3.34 / 1021.66 1 2
6 7 1194.08 20 11.04 2044 451 3.79 / 1022.12 2 3
7 14 -0.20 180 14.28 294 756 4.55 / 1022.87 2 4
Average= 4.94 (KJ/cycle)

Cycle 205 GMT 17/ 1/2020 0:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 29 14.21 430 177 0.18 / 1011.88 2 2
2 12 1119.68 5 11.84 1951 115 0.29 / 1012.00 1 1
3 12 1944.64 91 10.03 3133 2860 3.15 / 1014.86 1 2
4 12 1937.16 65 10.04 3106 2027 5.18 / 1016.89 1 2
5 7 1921.32 21 10.73 3074 693 5.87 / 1017.58 2 2
6 14 -0.08 180 14.33 288 743 6.61 / 1018.32 2 7
Average= 4.94 (KJ/cycle)

Cycle 204 GMT 15/ 1/2020 21: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 29 14.17 439 180 0.18 / 1007.47 2 2
2 12 1131.52 3 4.85 1479 22 0.20 / 1007.49 1 2
3 12 1218.52 91 8.77 2054 1639 1.84 / 1009.13 1 2
4 12 1222.40 65 10.06 2066 1351 3.19 / 1010.48 1 2
5 7 1210.24 21 10.99 2070 478 3.67 / 1010.96 2 2
6 14 0.00 180 14.28 290 745 4.42 / 1011.71 1 4
Average= 4.94 (KJ/cycle)

Cycle 203 GMT 6/ 1/2020 2:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 29 14.23 420 173 0.17 / 1003.03 2 2
2 12 1112.52 3 4.89 1616 24 0.20 / 1003.06 1 2
3 12 1214.04 90 9.15 2059 1696 1.89 / 1004.75 1 2
4 12 1216.20 64 10.14 2061 1338 3.23 / 1006.09 1 2
5 7 1202.84 20 11.02 2066 455 3.69 / 1006.55 2 2
6 14 -0.16 180 14.28 290 745 4.43 / 1007.29 1 4
Average= 4.94 (KJ/cycle)

Cycle 202 GMT 27/12/2019 8:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 28 14.25 412 164 0.16 / 998.46 2 2
2 12 1135.24 3 4.99 2031 30 0.19 / 998.49 1 2
3 12 1218.00 90 9.73 2071 1814 2.01 / 1000.30 1 1
4 12 1220.72 64 10.25 2066 1355 3.36 / 1001.66 1 2
5 7 1208.00 20 11.07 2071 459 3.82 / 1002.12 2 2
6 14 0.00 180 14.29 289 743 4.57 / 1002.86 1 3
Average= 4.94 (KJ/cycle)

Cycle 201 GMT 17/12/2019 14:54: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 29 14.19 434 179 0.18 / 991.70 1 2
2 12 1117.36 3 11.40 1961 67 0.25 / 991.76 1 1
3 12 1988.12 90 10.09 3178 2886 3.13 / 994.65 1 1
4 12 1980.68 64 10.10 3156 2040 5.17 / 996.69 1 2
5 7 1965.00 20 10.72 3144 674 5.85 / 997.36 2 2
6 13 15.48 39 14.27 320 178 6.02 / 997.54 1 2
7 14 0.04 180 14.34 292 754 6.78 / 998.30 1 16
Average= 4.94 (KJ/cycle)

Cycle 200 GMT 16/12/2019 11:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 29 14.18 447 184 0.18 / 987.03 2 2
2 12 1118.44 3 6.87 1904 39 0.22 / 987.07 1 1
3 12 1212.16 90 10.04 2068 1869 2.09 / 988.93 1 2
4 12 1213.68 64 10.39 2052 1364 3.46 / 990.30 2 2
5 7 1199.84 20 11.14 2058 459 3.91 / 990.76 2 2
6 14 -0.08 181 14.26 295 761 4.68 / 991.52 2 5
Average= 4.93 (KJ/cycle)

Cycle 199 GMT 6/12/2019 17:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 25 14.25 437 156 0.16 / 981.93 2 2
2 3 1102.76 3 12.48 1972 74 0.23 / 982.00 1 3
3 3 1047.24 1 12.20 1889 23 0.25 / 982.02 1 2
4 12 1146.52 5 11.21 1997 112 0.36 / 982.14 1 1
5 12 1201.56 90 11.17 2069 2080 2.44 / 984.22 1 2
6 12 1200.92 64 10.73 2045 1404 3.85 / 985.62 1 2
7 7 1185.36 20 11.26 2034 458 4.31 / 986.08 2 6
8 14 -0.28 180 14.29 297 764 5.07 / 986.84 2 10
Average= 4.93 (KJ/cycle)

Cycle 198 GMT 26/11/2019 23:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 29 14.24 437 180 0.18 / 975.06 2 2
2 12 1112.60 5 12.43 1954 121 0.30 / 975.18 1 1
3 12 1920.56 91 10.81 3090 3040 3.34 / 978.22 1 2
4 12 1912.36 64 10.71 3066 2102 5.44 / 980.33 1 1
5 7 1895.68 20 11.03 3065 676 6.12 / 981.00 1 1
6 14 -0.12 181 14.40 295 769 6.89 / 981.77 2 5
Average= 4.93 (KJ/cycle)

Cycle 197 GMT 25/11/2019 20:42: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 29 14.21 452 186 0.19 / 968.20 2 2
2 12 1125.76 5 12.39 1978 123 0.31 / 968.32 1 2
3 12 1928.44 90 10.78 3103 3011 3.32 / 971.33 1 2
4 12 1920.48 64 10.70 3077 2107 5.43 / 973.44 1 1
5 7 1904.08 20 11.03 3080 679 6.11 / 974.12 1 2
6 14 -0.04 180 14.40 296 767 6.87 / 974.88 2 7
Average= 4.92 (KJ/cycle)

Cycle 196 GMT 24/11/2019 17:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 29 14.28 429 178 0.18 / 961.29 2 2
2 12 1093.80 5 12.43 1937 120 0.30 / 961.41 1 2
3 12 1920.92 90 10.75 3095 2994 3.29 / 964.40 1 1
4 12 1913.08 65 10.68 3079 2137 5.43 / 966.54 1 2
5 7 1896.76 21 11.03 3085 715 6.14 / 967.25 2 1
6 14 -0.08 180 14.40 292 757 6.90 / 968.01 2 4
Average= 4.91 (KJ/cycle)

Cycle 195 GMT 23/11/2019 14:28: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 29 14.24 435 180 0.18 / 954.48 2 2
2 12 1102.60 5 12.32 1962 121 0.30 / 954.60 1 1
3 12 1924.28 90 10.68 3098 2978 3.28 / 957.58 1 2
4 12 1916.28 64 10.66 3069 2094 5.37 / 959.67 1 2
5 7 1900.28 20 11.06 3058 676 6.05 / 960.35 2 2
6 14 0.04 181 14.39 293 763 6.81 / 961.11 2 4
Average= 4.90 (KJ/cycle)

Cycle 194 GMT 22/11/2019 11:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 29 14.24 446 184 0.18 / 947.64 2 2
2 12 1124.08 5 12.29 1974 121 0.31 / 947.76 1 2
3 12 1928.08 90 10.69 3096 2979 3.28 / 950.74 1 2
4 12 1920.28 64 10.65 3089 2105 5.39 / 952.85 1 2
5 7 1903.76 20 11.01 3075 677 6.07 / 953.52 2 2
6 14 0.00 181 14.39 297 774 6.84 / 954.30 2 6
Average= 4.89 (KJ/cycle)

Cycle 193 GMT 21/11/2019 8:13: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 29 14.19 428 176 0.18 / 940.80 2 2
2 3 972.28 -1 14.19 428 0 0.00 / 940.80 2 2
3 3 1031.28 1 11.91 1837 22 0.20 / 940.83 1 2
4 12 1143.36 5 12.09 1995 121 0.32 / 940.95 1 1
5 12 1917.24 90 10.61 3074 2935 3.25 / 943.88 1 2
6 12 1909.12 65 10.62 3055 2109 5.36 / 945.99 1 2
7 7 1892.00 21 11.03 3055 708 6.07 / 946.70 2 2
8 14 -0.12 180 14.39 293 759 6.83 / 947.46 1 5
Average= 4.88 (KJ/cycle)

Cycle 192 GMT 20/11/2019 5: 5: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 29 14.22 425 175 0.18 / 934.00 1 2
2 12 1091.52 5 12.02 1917 115 0.29 / 934.11 1 1
3 12 1928.48 91 10.42 3107 2946 3.24 / 937.06 1 2
4 12 1920.68 65 10.49 3080 2100 5.34 / 939.16 1 1
5 7 1904.12 21 10.97 3098 714 6.05 / 939.87 1 1
6 14 -0.08 180 14.36 292 755 6.81 / 940.63 2 4
Average= 4.87 (KJ/cycle)

Cycle 191 GMT 19/11/2019 1:51:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 29 14.18 446 183 0.18 / 927.28 2 2
2 12 1108.80 5 11.81 1972 116 0.30 / 927.40 1 2
3 12 1937.00 90 10.32 3103 2882 3.18 / 930.28 1 2
4 12 1929.48 65 10.31 3098 2076 5.26 / 932.36 1 1
5 7 1913.52 21 10.94 3069 705 5.96 / 933.06 1 2
6 14 -0.12 180 14.33 294 758 6.72 / 933.82 1 5
Average= 4.86 (KJ/cycle)

Cycle 190 GMT 17/11/2019 22:38:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 29 14.17 435 179 0.18 / 920.71 2 2
2 12 1104.24 5 11.75 1947 114 0.29 / 920.83 1 2
3 12 1933.80 90 10.15 3110 2841 3.13 / 923.67 1 2
4 12 1926.76 64 10.17 3082 2006 5.14 / 925.68 1 2
5 7 1911.56 20 10.75 3105 668 5.81 / 926.34 2 2
6 14 0.00 180 14.31 294 757 6.56 / 927.10 2 6
Average= 4.85 (KJ/cycle)

Cycle 189 GMT 16/11/2019 19:19:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 29 14.20 443 182 0.18 / 914.22 2 2
2 12 1124.28 5 11.67 1956 114 0.30 / 914.33 1 1
3 12 1945.60 90 9.78 3121 2747 3.04 / 917.08 1 2
4 12 1938.60 65 9.93 3114 2010 5.05 / 919.09 1 1
5 7 1923.44 21 10.63 3106 693 5.75 / 919.78 1 1
6 14 0.00 180 14.30 293 754 6.50 / 920.54 2 5
Average= 4.84 (KJ/cycle)

Cycle 188 GMT 15/11/2019 15:42: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 30 14.20 440 187 0.19 / 907.19 2 2
2 3 970.56 -1 14.20 440 0 0.00 / 907.19 2 2
3 3 1037.64 1 11.17 1847 21 0.21 / 907.21 1 1
4 12 1142.68 10 6.98 1967 137 0.35 / 907.35 1 1
5 12 1986.88 90 5.07 2866 1308 1.65 / 908.65 1 2
6 12 1987.60 65 5.83 3224 1222 2.87 / 909.88 1 2
7 7 1984.96 21 10.09 3206 679 3.55 / 910.55 2 2
8 13 1827.24 39 11.97 2954 1379 4.93 / 911.93 1 2
9 13 1170.28 39 12.91 1989 1001 5.93 / 912.93 1 2
10 13 209.80 39 13.96 620 338 6.27 / 913.27 1 2
11 14 -0.12 180 14.35 295 762 7.03 / 914.03 2 10
Average= 4.84 (KJ/cycle)

Cycle 187 GMT 5/11/2019 13:46: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 29 14.21 435 179 0.18 / 900.17 2 2
2 3 1022.24 1 11.18 1812 20 0.20 / 900.19 1 1
3 12 1122.48 10 6.86 1880 129 0.33 / 900.32 1 1
4 12 1997.52 90 5.04 2766 1255 1.58 / 901.58 1 2
5 12 1997.28 64 5.73 3173 1164 2.75 / 902.74 1 2
6 7 1994.12 20 10.07 3239 652 3.40 / 903.39 2 2
7 13 1840.44 39 11.95 2999 1398 4.80 / 904.79 1 2
8 13 1393.84 39 12.70 2304 1141 5.94 / 905.93 1 3
9 13 171.80 39 14.02 564 308 6.25 / 906.24 1 2
10 14 0.00 181 14.35 293 761 7.01 / 907.00 2 10
Average= 4.82 (KJ/cycle)

Cycle 186 GMT 26/10/2019 11:51: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 29 14.26 433 179 0.18 / 893.39 2 2
2 3 969.44 -1 14.26 433 0 0.00 / 893.39 2 2
3 3 1032.48 1 11.15 1860 21 0.20 / 893.41 1 1
4 12 1138.56 11 7.31 1921 154 0.35 / 893.57 1 1
5 12 1988.84 81 5.07 2873 1180 1.53 / 894.75 1 2
6 12 1989.04 58 5.98 3217 1116 2.65 / 895.86 1 2
7 7 1986.20 21 10.10 3233 686 3.34 / 896.55 2 2
8 13 1834.72 39 11.95 2995 1396 4.73 / 897.94 1 2
9 13 1163.00 39 12.95 1961 990 5.72 / 898.94 1 1
10 13 162.20 39 14.03 550 301 6.02 / 899.24 1 2
11 14 -0.24 180 14.35 293 757 6.78 / 899.99 2 5
Average= 4.81 (KJ/cycle)

Cycle 185 GMT 16/10/2019 9:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 28 14.24 439 175 0.18 / 886.60 2 2
2 3 1019.36 1 11.36 1820 21 0.20 / 886.62 1 1
3 12 1128.56 11 7.58 1925 161 0.36 / 886.78 1 2
4 12 1993.76 80 5.11 2990 1222 1.58 / 888.00 1 2
5 12 1993.48 58 6.40 3274 1215 2.79 / 889.21 1 2
6 7 1989.44 21 10.24 3215 691 3.49 / 889.91 2 2
7 13 1812.44 39 12.06 2935 1380 4.87 / 891.29 1 1
8 13 1131.24 39 12.99 1906 966 5.83 / 892.25 1 2
9 13 43.36 39 14.25 366 203 6.03 / 892.45 1 2
10 14 -0.08 180 14.38 293 758 6.79 / 893.21 1 10
Average= 4.80 (KJ/cycle)

Cycle 184 GMT 6/10/2019 8: 2: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 29 14.22 434 179 0.18 / 879.83 2 2
2 3 967.76 -1 14.22 434 0 0.00 / 879.83 2 2
3 3 1029.92 1 11.46 1841 21 0.20 / 879.85 1 1
4 12 1144.40 11 7.64 1918 161 0.36 / 880.01 1 1
5 12 1985.88 80 5.11 3021 1235 1.60 / 881.25 1 2
6 12 1986.00 58 6.62 3228 1239 2.84 / 882.49 1 2
7 7 1982.68 20 10.25 3204 657 3.49 / 883.15 2 1
8 13 1784.96 39 12.13 2886 1365 4.86 / 884.51 1 2
9 13 1084.64 39 13.04 1849 940 5.80 / 885.45 1 5
10 13 67.48 39 14.23 398 221 6.02 / 885.67 1 2
11 14 -0.08 180 14.39 289 749 6.77 / 886.42 2 7
Average= 4.79 (KJ/cycle)

Cycle 183 GMT 26/ 9/2019 6:18:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 29 14.21 449 185 0.19 / 873.31 1 2
2 12 1116.12 11 8.08 1884 167 0.35 / 873.48 1 1
3 12 1982.36 80 5.11 3022 1235 1.59 / 874.71 1 2
4 12 1982.56 45 7.08 3229 1029 2.62 / 875.74 1 1
5 7 1979.44 20 10.26 3187 654 3.27 / 876.40 1 1
6 13 1791.92 39 12.07 2906 1368 4.64 / 877.76 1 2
7 13 1070.28 39 13.03 1852 941 5.58 / 878.71 1 4
8 13 33.36 39 14.29 347 193 5.77 / 878.90 1 2
9 14 0.00 180 14.39 291 754 6.53 / 879.65 1 6
Average= 4.78 (KJ/cycle)

Cycle 182 GMT 16/ 9/2019 4:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 29 14.20 442 182 0.18 / 866.71 2 2
2 12 1102.24 11 7.60 1901 159 0.34 / 866.87 1 1
3 12 1990.20 81 5.11 2996 1240 1.58 / 868.11 1 2
4 12 1990.16 46 6.96 3265 1045 2.63 / 869.15 1 2
5 7 1987.12 21 10.31 3190 691 3.32 / 869.85 2 2
6 13 1801.64 39 12.10 2944 1389 4.71 / 871.23 1 1
7 13 1091.68 39 13.02 1877 953 5.66 / 872.19 1 4
8 13 3.00 39 14.36 304 170 5.83 / 872.36 2 2
9 14 -0.12 181 14.38 295 768 6.60 / 873.13 2 11
Average= 4.77 (KJ/cycle)

Cycle 181 GMT 6/ 9/2019 2:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 29 14.24 447 185 0.18 / 860.63 2 2
2 12 1106.00 11 7.80 1917 164 0.35 / 860.80 1 1
3 12 1990.20 65 5.14 3092 1033 1.38 / 861.83 1 2
4 12 1990.40 45 7.63 3155 1083 2.47 / 862.91 1 1
5 7 1987.12 20 10.27 3210 659 3.12 / 863.57 1 2
6 13 1795.48 39 12.09 2924 1379 4.50 / 864.95 1 1
7 13 871.04 39 13.24 1546 798 5.30 / 865.75 1 2
8 14 -0.04 181 14.33 300 778 6.08 / 866.53 2 4
Average= 4.76 (KJ/cycle)

Cycle 180 GMT 27/ 8/2019 1: 7: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 29 14.24 445 184 0.18 / 854.20 2 2
2 12 1112.88 11 7.96 1906 167 0.35 / 854.37 1 2
3 12 2000.68 65 5.14 3093 1033 1.38 / 855.40 1 2
4 12 2001.36 45 7.49 3199 1078 2.46 / 856.48 1 1
5 7 1998.40 20 10.21 3234 660 3.12 / 857.14 1 2
6 13 1804.68 39 12.12 2924 1382 4.50 / 858.52 1 2
7 13 1088.56 39 13.02 1877 953 5.46 / 859.47 1 5
8 13 58.64 39 14.24 388 215 5.67 / 859.69 1 2
9 14 -0.28 180 14.37 294 760 6.43 / 860.45 1 6
Average= 4.75 (KJ/cycle)

Cycle 179 GMT 17/ 8/2019 0:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 29 14.22 438 181 0.18 / 847.82 2 2
2 3 971.12 -1 14.22 438 0 0.00 / 847.82 2 2
3 3 1030.84 1 11.85 1836 22 0.20 / 847.84 1 2
4 12 1127.60 11 8.29 1909 174 0.38 / 848.01 1 1
5 12 1979.48 65 5.16 3221 1080 1.46 / 849.09 1 2
6 12 1979.68 46 8.21 3145 1188 2.64 / 850.28 1 2
7 7 1976.08 21 10.35 3194 694 3.34 / 850.97 2 2
8 13 1774.84 39 12.11 2876 1358 4.70 / 852.33 1 2
9 13 1050.68 39 13.06 1808 921 5.62 / 853.25 1 4
10 14 -0.20 180 14.35 295 762 6.38 / 854.01 2 7
Average= 4.74 (KJ/cycle)

Cycle 178 GMT 6/ 8/2019 22:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 30 14.23 447 191 0.19 / 842.33 2 2
2 3 972.00 -1 14.23 447 0 0.00 / 842.33 2 2
3 3 1033.52 1 11.99 1847 22 0.21 / 842.35 1 1
4 12 1140.04 13 8.93 1979 230 0.44 / 842.58 1 2
5 12 1931.96 65 6.66 3067 1328 1.77 / 843.91 1 2
6 12 1929.28 45 8.51 3073 1177 2.95 / 845.08 1 2
7 7 1920.68 21 10.42 3113 681 3.63 / 845.76 2 1
8 13 1041.76 39 12.96 1822 921 4.55 / 846.68 1 3
9 13 36.68 39 14.28 352 196 4.75 / 846.88 1 2
10 14 0.04 180 14.35 292 754 5.50 / 847.63 2 8
Average= 4.74 (KJ/cycle)

Cycle 177 GMT 27/ 7/2019 21:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 30 14.27 428 183 0.18 / 836.67 2 2
2 12 1095.84 13 8.91 1871 217 0.40 / 836.89 1 1
3 12 1937.88 65 6.64 3074 1327 1.73 / 838.22 1 1
4 12 1936.52 45 8.86 3090 1232 2.96 / 839.45 1 1
5 7 1929.20 21 10.35 3116 677 3.64 / 840.12 1 2
6 13 1212.80 39 12.82 2024 1012 4.65 / 841.14 1 6
7 13 102.80 39 14.17 455 251 4.90 / 841.39 1 2
8 14 -0.12 180 14.36 289 747 5.65 / 842.14 2 8
Average= 4.73 (KJ/cycle)

Cycle 176 GMT 17/ 7/2019 19:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 30 14.27 436 187 0.19 / 830.15 1 2
2 12 2008.20 91 5.70 3138 1628 1.81 / 831.78 1 2
3 7 2012.76 21 10.48 3233 712 2.53 / 832.49 2 1
4 13 1876.52 39 12.01 3045 1426 3.95 / 833.91 1 1
5 13 1659.28 39 12.43 2701 1309 5.26 / 835.22 1 2
6 13 436.12 39 13.75 959 514 5.78 / 835.74 1 2
7 14 -0.16 180 14.39 290 751 6.53 / 836.49 2 7
Average= 4.73 (KJ/cycle)

Cycle 175 GMT 7/ 7/2019 19:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 30 14.31 433 186 0.19 / 823.79 2 2
2 12 2008.20 90 5.53 3064 1525 1.71 / 825.32 1 2
3 7 2013.76 20 10.45 3263 682 2.39 / 826.00 2 2
4 13 1910.68 39 11.99 3081 1441 3.83 / 827.44 1 1
5 13 1495.60 39 12.61 2445 1202 5.04 / 828.64 1 2
6 13 527.48 39 13.65 1089 580 5.62 / 829.22 1 2
7 14 -0.04 180 14.41 286 742 6.36 / 829.96 2 5
Average= 4.72 (KJ/cycle)

Cycle 174 GMT 27/ 6/2019 19:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 30 14.30 433 186 0.19 / 817.63 2 2
2 12 2004.28 91 6.13 3087 1722 1.91 / 819.36 1 2
3 7 2007.84 21 10.51 3254 718 2.63 / 820.07 2 2
4 13 1846.16 40 12.03 3000 1444 4.07 / 821.52 1 2
5 13 1189.16 39 12.93 2022 1020 5.09 / 822.54 1 2
6 13 209.80 39 14.10 601 330 5.42 / 822.87 1 2
7 14 -0.04 180 14.43 284 738 6.16 / 823.60 1 4
Average= 4.71 (KJ/cycle)

Cycle 173 GMT 17/ 6/2019 19:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 30 14.34 425 183 0.18 / 811.51 2 2
2 12 2001.48 90 6.13 3066 1692 1.87 / 813.20 1 2
3 7 2007.12 21 10.60 3239 721 2.60 / 813.92 2 2
4 13 1846.64 39 12.14 2988 1415 4.01 / 815.33 1 2
5 13 1199.28 39 12.93 2042 1030 5.04 / 816.36 1 4
6 13 224.76 39 14.07 632 347 5.39 / 816.71 1 2
7 14 -0.12 180 14.42 284 737 6.12 / 817.45 2 6
Average= 4.70 (KJ/cycle)

Cycle 172 GMT 7/ 6/2019 20: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 30 14.37 420 181 0.18 / 805.17 2 2
2 12 2009.00 90 6.07 3011 1645 1.83 / 806.82 1 1
3 7 2012.68 20 10.66 3223 687 2.51 / 807.50 1 1
4 13 1861.96 39 12.18 3012 1431 3.94 / 808.94 1 2
5 13 1409.80 39 12.76 2314 1152 5.10 / 810.09 1 2
6 13 404.08 39 13.82 914 493 5.59 / 810.58 1 2
7 14 0.12 181 14.42 285 744 6.33 / 811.32 2 11
Average= 4.69 (KJ/cycle)

Cycle 171 GMT 28/ 5/2019 20:29: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 30 14.36 422 182 0.18 / 799.13 2 2
2 3 961.28 -1 14.36 422 0 0.00 / 799.13 2 2
3 3 1031.60 1 12.37 1853 23 0.20 / 799.15 1 2
4 12 2003.56 70 6.00 2941 1235 1.44 / 800.39 1 2
5 7 2007.60 21 10.56 3243 719 2.16 / 801.11 2 2
6 13 1891.52 39 12.11 3060 1445 3.60 / 802.55 1 2
7 13 1440.36 39 12.70 2371 1174 4.78 / 803.73 1 2
8 13 442.96 39 13.77 974 523 5.30 / 804.25 1 2
9 14 -0.20 180 14.42 285 740 6.04 / 804.99 2 5
Average= 4.68 (KJ/cycle)

Cycle 170 GMT 18/ 5/2019 20:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 30 14.32 436 187 0.19 / 793.43 2 2
2 12 2003.36 69 6.26 2923 1263 1.45 / 794.69 1 2
3 7 2006.92 20 10.61 3239 687 2.14 / 795.38 2 2
4 13 1861.52 39 12.13 3016 1427 3.56 / 796.81 1 1
5 13 1221.12 39 12.92 2060 1038 4.60 / 797.85 1 3
6 13 254.12 39 14.02 678 371 4.97 / 798.22 1 2
7 14 -0.24 180 14.43 282 732 5.71 / 798.95 1 8
Average= 4.67 (KJ/cycle)

Cycle 169 GMT 8/ 5/2019 21: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 28 14.34 435 175 0.17 / 787.98 2 2
2 3 1040.56 1 12.65 1867 24 0.20 / 788.00 1 4
3 3 1023.64 1 12.25 1833 22 0.22 / 788.03 1 1
4 12 1136.72 8 5.01 2226 89 0.31 / 788.12 1 2
5 12 2002.84 59 7.29 3142 1351 1.66 / 789.47 1 2
6 7 2002.36 20 10.58 3217 681 2.34 / 790.15 2 1
7 13 1807.92 39 12.19 2941 1398 3.74 / 791.55 1 1
8 13 1091.48 39 13.03 1888 959 4.70 / 792.50 1 3
9 14 0.08 180 14.43 285 740 5.44 / 793.25 2 3
Average= 4.67 (KJ/cycle)

Cycle 168 GMT 28/ 4/2019 20:55: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 29 14.35 429 179 0.18 / 782.33 2 2
2 3 973.28 -1 14.35 429 0 0.00 / 782.33 2 2
3 12 1163.80 8 5.00 2226 89 0.27 / 782.41 1 2
4 12 2000.64 59 7.55 3180 1417 1.68 / 783.83 1 2
5 7 2000.00 20 10.62 3223 685 2.37 / 784.52 2 2
6 13 1802.24 39 12.18 2925 1389 3.76 / 785.91 1 2
7 13 1084.04 39 13.05 1855 944 4.70 / 786.85 1 4
8 13 55.36 39 14.35 374 209 4.91 / 787.06 2 2
9 14 -0.04 181 14.42 286 746 5.66 / 787.81 2 10
Average= 4.66 (KJ/cycle)

Cycle 167 GMT 18/ 4/2019 21:11: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 29 14.33 423 176 0.18 / 776.83 2 2
2 12 1120.24 8 5.00 2231 89 0.27 / 776.91 1 2
3 12 2003.08 59 7.63 3179 1431 1.70 / 778.35 1 2
4 7 2002.16 20 10.65 3232 688 2.38 / 779.03 2 2
5 13 1800.40 39 12.17 2937 1394 3.78 / 780.43 1 1
6 13 865.16 39 13.26 1564 809 4.59 / 781.24 1 2
7 13 16.76 39 14.41 310 174 4.76 / 781.41 1 2
8 14 0.08 180 14.40 284 736 5.50 / 782.15 2 12
Average= 4.66 (KJ/cycle)

Cycle 166 GMT 8/ 4/2019 21: 7: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 28 14.37 428 172 0.17 / 771.30 2 2
2 3 1025.80 1 12.49 1875 23 0.20 / 771.32 1 1
3 12 1135.92 8 7.58 1943 118 0.31 / 771.44 1 2
4 12 2003.56 60 8.33 3218 1608 1.92 / 773.05 1 2
5 7 2001.56 21 10.63 3223 719 2.64 / 773.77 2 2
6 13 1781.24 39 12.20 2889 1375 4.02 / 775.14 1 1
7 13 798.20 39 13.31 1474 765 4.78 / 775.91 1 4
8 14 -0.08 180 14.40 286 741 5.52 / 776.65 2 4
Average= 4.65 (KJ/cycle)

Cycle 165 GMT 29/ 3/2019 21: 7: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 28 14.37 423 170 0.17 / 765.84 2 2
2 12 1116.80 8 8.70 1955 136 0.31 / 765.97 1 2
3 12 2000.40 59 8.50 3199 1604 1.91 / 767.58 1 1
4 7 1996.72 20 10.59 3212 680 2.59 / 768.26 1 2
5 13 1778.16 39 12.15 2875 1362 3.95 / 769.62 1 2
6 13 792.56 39 13.29 1469 761 4.71 / 770.38 1 3
7 14 -0.08 181 14.37 286 744 5.46 / 771.13 2 7
Average= 4.65 (KJ/cycle)

Cycle 164 GMT 19/ 3/2019 20:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 28 14.38 417 168 0.17 / 760.34 2 2
2 12 1118.44 7 8.14 1938 110 0.28 / 760.45 1 1
3 12 2014.68 56 8.61 3192 1539 1.82 / 761.98 1 2
4 7 2014.00 21 10.30 3231 699 2.52 / 762.68 2 1
5 13 1798.84 37 12.13 2923 1312 3.83 / 764.00 1 1
6 13 835.16 37 13.26 1524 748 4.58 / 764.74 1 2
7 13 34.20 37 14.36 344 183 4.76 / 764.93 2 2
8 14 -0.16 180 14.38 287 743 5.50 / 765.67 2 8
Average= 4.64 (KJ/cycle)

Cycle 163 GMT 9/ 3/2019 20:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 29 14.34 427 178 0.18 / 754.78 2 2
2 3 964.84 -1 14.34 427 0 0.00 / 754.78 2 2
3 3 1029.48 1 12.35 1882 23 0.20 / 754.80 1 1
4 12 1144.76 7 8.66 1969 119 0.32 / 754.92 1 1
5 12 2004.48 56 8.82 3228 1594 1.91 / 756.52 1 1
6 7 2003.12 21 10.23 3238 696 2.61 / 757.21 1 2
7 13 1784.48 37 12.16 2908 1308 3.92 / 758.52 1 2
8 13 797.00 37 13.30 1464 720 4.64 / 759.24 1 3
9 13 25.16 37 14.36 334 177 4.82 / 759.42 1 2
10 14 0.12 180 14.36 289 747 5.56 / 760.17 2 3
Average= 4.64 (KJ/cycle)

Cycle 162 GMT 27/ 2/2019 19:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 29 14.33 424 176 0.18 / 749.20 2 2
2 12 1124.24 7 7.85 1961 108 0.28 / 749.31 1 2
3 12 2000.88 56 8.65 3183 1542 1.83 / 750.85 1 2
4 7 1999.36 21 10.23 3222 692 2.52 / 751.54 2 1
5 13 1781.04 37 12.13 2865 1286 3.80 / 752.83 1 2
6 13 1022.08 37 13.04 1774 856 4.66 / 753.69 1 2
7 13 20.92 37 14.35 329 175 4.83 / 753.86 1 2
8 14 -0.08 180 14.35 288 744 5.58 / 754.60 2 12
Average= 4.63 (KJ/cycle)

Cycle 161 GMT 17/ 2/2019 19:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 29 14.33 428 178 0.18 / 744.96 2 2
2 12 1114.92 6 8.93 1945 104 0.28 / 745.07 1 1
3 12 1588.96 56 9.54 2627 1403 1.69 / 746.47 1 2
4 7 1587.56 21 10.59 2615 582 2.27 / 747.05 2 2
5 13 1370.76 23 12.75 2321 681 2.95 / 747.73 1 3
6 13 707.72 23 13.47 1354 419 3.37 / 748.15 1 3
7 13 71.32 23 14.27 412 135 3.50 / 748.29 1 2
8 14 -0.20 180 14.35 286 739 4.24 / 749.03 1 7
Average= 4.62 (KJ/cycle)

Cycle 160 GMT 7/ 2/2019 18: 9: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 29 14.32 437 181 0.18 / 740.18 2 2
2 12 1118.60 6 9.01 1920 104 0.29 / 740.28 1 1
3 12 2001.76 55 9.03 3184 1581 1.87 / 741.86 1 1
4 7 2000.12 20 10.28 3200 658 2.52 / 742.52 1 2
5 13 1573.60 24 12.66 2573 782 3.31 / 743.30 1 3
6 13 910.28 24 13.28 1627 519 3.82 / 743.82 1 6
7 13 238.92 24 14.02 669 225 4.05 / 744.04 1 2
8 14 -0.04 180 14.37 286 740 4.79 / 744.78 2 5
Average= 4.63 (KJ/cycle)

Cycle 159 GMT 28/ 1/2019 17:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 29 14.31 426 177 0.18 / 735.24 2 2
2 12 1108.72 6 9.48 1914 109 0.29 / 735.35 1 2
3 12 2001.96 55 9.17 3193 1610 1.90 / 736.96 1 1
4 7 1999.76 20 10.33 3225 666 2.56 / 737.62 1 1
5 13 1572.80 24 12.67 2572 782 3.34 / 738.40 1 2
6 13 1107.76 23 13.12 1890 570 3.91 / 738.97 1 2
7 13 380.80 23 13.85 876 279 4.19 / 739.25 1 2
8 14 -0.12 181 14.37 285 741 4.94 / 739.99 2 3
Average= 4.62 (KJ/cycle)

Cycle 158 GMT 18/ 1/2019 16:52: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 29 14.34 428 178 0.18 / 729.98 2 2
2 12 1106.16 6 9.66 1914 111 0.29 / 730.09 1 2
3 12 2004.88 50 9.24 3175 1467 1.76 / 731.56 1 2
4 7 2003.52 20 10.34 3214 665 2.42 / 732.22 2 1
5 13 1793.64 33 12.18 2919 1173 3.59 / 733.39 1 1
6 13 824.28 34 13.27 1515 684 4.28 / 734.08 1 3
7 13 133.32 34 14.17 502 242 4.52 / 734.32 1 2
8 14 -0.16 180 14.36 286 739 5.26 / 735.06 1 7
Average= 4.62 (KJ/cycle)

Cycle 157 GMT 8/ 1/2019 16:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 29 14.32 430 179 0.18 / 724.65 2 2
2 12 1110.08 6 10.19 1957 120 0.30 / 724.77 1 2
3 12 2005.92 50 9.36 3157 1477 1.78 / 726.25 1 2
4 7 2004.24 20 10.36 3235 670 2.45 / 726.92 2 2
5 13 1784.48 33 12.22 2909 1173 3.62 / 728.09 1 2
6 13 1020.60 34 13.10 1766 787 4.41 / 728.88 1 3
7 13 52.16 34 14.34 372 181 4.59 / 729.06 1 2
8 14 -0.04 181 14.38 285 742 5.33 / 729.80 2 7
Average= 4.62 (KJ/cycle)

Cycle 156 GMT 29/12/2018 15:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 29 14.34 431 179 0.18 / 719.43 2 2
2 12 1126.76 5 10.02 1952 98 0.28 / 719.53 1 1
3 12 2001.44 50 9.36 3192 1494 1.77 / 721.02 1 2
4 7 2000.36 20 10.34 3221 666 2.44 / 721.69 2 2
5 13 1794.76 33 12.18 2932 1178 3.62 / 722.86 1 2
6 13 839.84 33 13.26 1538 673 4.29 / 723.54 1 2
7 13 33.40 33 14.37 342 162 4.45 / 723.70 1 2
8 14 -0.04 190 14.38 283 773 5.22 / 724.47 1 6
Average= 4.61 (KJ/cycle)

Cycle 155 GMT 19/12/2018 15:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 29 14.29 427 177 0.18 / 714.39 2 2
2 12 1118.72 5 10.17 1936 98 0.28 / 714.49 1 2
3 12 2002.84 51 9.34 3194 1521 1.80 / 716.01 1 2
4 7 2001.64 21 10.42 3199 700 2.50 / 716.71 2 2
5 13 1573.68 34 12.47 2564 1087 3.58 / 717.80 1 2
6 13 838.20 33 13.28 1519 666 4.25 / 718.47 1 5
7 14 -0.04 190 14.36 287 783 5.03 / 719.25 2 5
Average= 4.61 (KJ/cycle)

Cycle 154 GMT 9/12/2018 15:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 29 14.32 433 180 0.18 / 709.44 2 2
2 12 1111.80 4 10.23 1931 79 0.26 / 709.52 1 1
3 12 2006.16 50 9.43 3209 1513 1.77 / 711.03 1 2
4 7 2005.32 20 10.40 3203 666 2.44 / 711.70 2 1
5 13 1557.84 33 12.50 2557 1055 3.49 / 712.75 1 1
6 13 853.28 33 13.26 1550 678 4.17 / 713.43 1 3
7 14 -0.16 190 14.35 288 785 4.96 / 714.22 2 5
Average= 4.61 (KJ/cycle)

Cycle 153 GMT 29/11/2018 15: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 29 14.29 435 180 0.18 / 704.47 2 2
2 12 1117.04 4 10.52 1960 82 0.26 / 704.55 1 1
3 12 2002.88 50 9.54 3193 1523 1.79 / 706.08 1 2
4 7 2001.04 20 10.39 3228 671 2.46 / 706.75 2 2
5 13 1568.64 33 12.50 2558 1055 3.51 / 707.80 1 2
6 13 841.68 33 13.28 1528 670 4.18 / 708.47 1 2
7 14 -0.12 190 14.35 289 788 4.97 / 709.26 2 7
Average= 4.61 (KJ/cycle)

Cycle 152 GMT 19/11/2018 14:47: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 29 14.31 433 180 0.18 / 699.27 2 2
2 12 1121.48 4 10.93 1982 87 0.27 / 699.35 1 1
3 12 2001.80 51 9.57 3209 1566 1.83 / 700.92 1 2
4 7 1999.52 21 10.44 3235 709 2.54 / 701.63 2 2
5 13 1563.80 33 12.51 2575 1063 3.60 / 702.69 1 2
6 13 837.04 33 13.29 1519 666 4.27 / 703.36 1 2
7 13 12.56 33 14.39 313 149 4.42 / 703.51 2 2
8 14 -0.08 190 14.32 288 784 5.20 / 704.29 2 7
Average= 4.60 (KJ/cycle)

Cycle 151 GMT 9/11/2018 14:41: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 29 14.34 430 179 0.18 / 694.29 2 2
2 12 1100.20 4 11.31 1931 87 0.27 / 694.38 1 1
3 12 2001.16 50 9.76 3184 1554 1.82 / 695.93 1 1
4 7 1999.20 20 10.46 3205 670 2.49 / 696.60 1 2
5 13 1556.56 33 12.55 2515 1042 3.53 / 697.64 1 2
6 13 831.96 33 13.31 1475 648 4.18 / 698.29 1 6
7 14 -0.12 190 14.32 292 794 4.97 / 699.09 2 7
Average= 4.60 (KJ/cycle)

Cycle 150 GMT 30/10/2018 14:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 29 14.28 447 185 0.19 / 689.22 2 2
2 3 967.44 -1 14.28 447 0 0.00 / 689.22 2 2
3 3 1040.72 1 12.26 1894 23 0.21 / 689.25 1 2
4 12 1145.48 4 11.30 2026 92 0.30 / 689.34 1 2
5 12 2001.04 50 9.82 3179 1561 1.86 / 690.90 1 1
6 7 1998.28 20 10.50 3216 675 2.54 / 691.57 1 2
7 13 1559.32 34 12.53 2532 1079 3.61 / 692.65 1 2
8 13 811.88 34 13.31 1480 670 4.28 / 693.32 1 3
9 14 -0.08 190 14.34 290 790 5.07 / 694.11 2 3
Average= 4.60 (KJ/cycle)

Cycle 149 GMT 20/10/2018 13:18:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 28 14.31 439 176 0.18 / 684.10 2 2
2 3 1029.32 1 12.33 1877 23 0.20 / 684.13 1 2
3 12 1128.32 4 11.47 2007 92 0.29 / 684.22 1 2
4 12 2001.28 50 9.87 3210 1584 1.88 / 685.80 1 2
5 7 1998.48 20 10.55 3213 678 2.55 / 686.48 2 2
6 13 1567.24 33 12.52 2547 1052 3.61 / 687.53 1 2
7 13 625.88 33 13.51 1232 549 4.15 / 688.08 1 3
8 13 26.72 33 14.35 339 161 4.32 / 688.24 2 2
9 14 -0.04 190 14.32 292 794 5.11 / 689.04 2 11
Average= 4.59 (KJ/cycle)

Cycle 148 GMT 10/10/2018 12:30:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 28 14.29 439 176 0.18 / 679.09 2 2
2 12 1128.84 4 11.49 1977 91 0.27 / 679.18 1 1
3 12 2002.00 51 9.87 3189 1605 1.87 / 680.79 1 2
4 7 1999.40 21 10.53 3220 712 2.58 / 681.50 2 2
5 13 1556.16 34 12.51 2561 1089 3.67 / 682.59 1 2
6 13 630.56 33 13.51 1219 543 4.22 / 683.13 1 2
7 14 -0.16 190 14.31 292 794 5.01 / 683.93 2 5
Average= 4.59 (KJ/cycle)

Cycle 147 GMT 30/ 9/2018 11:54: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 29 14.29 448 186 0.19 / 674.05 1 2
2 3 967.96 -1 14.29 448 0 0.00 / 674.05 1 2
3 3 1029.04 1 12.09 1867 23 0.21 / 674.07 1 1
4 12 1148.40 4 11.74 1998 94 0.30 / 674.16 1 1
5 12 2002.40 50 9.98 3190 1592 1.89 / 675.75 1 1
6 7 1999.36 20 10.56 3203 676 2.57 / 676.43 1 1
7 13 1550.92 33 12.55 2524 1045 3.62 / 677.48 1 3
8 13 810.12 33 13.31 1480 650 4.27 / 678.13 1 3
9 14 0.00 190 14.32 291 792 5.06 / 678.92 1 5
Average= 4.59 (KJ/cycle)

Cycle 146 GMT 20/ 9/2018 10:55:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 28 14.28 452 181 0.18 / 668.80 2 2
2 12 1114.04 4 11.71 1979 93 0.27 / 668.89 1 2
3 12 2000.56 50 9.98 3221 1607 1.88 / 670.50 1 2
4 7 1997.48 20 10.64 3188 678 2.56 / 671.18 2 2
5 13 1539.28 34 12.55 2518 1074 3.63 / 672.25 1 3
6 13 801.60 34 13.31 1463 662 4.30 / 672.92 1 2
7 13 3.56 34 14.42 304 149 4.44 / 673.06 1 2
8 14 -0.16 190 14.29 293 796 5.24 / 673.86 2 8
Average= 4.58 (KJ/cycle)

Cycle 145 GMT 10/ 9/2018 9:59: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 28 14.34 431 173 0.17 / 663.73 2 2
2 12 1101.56 4 11.79 1931 91 0.26 / 663.82 1 1
3 12 2001.60 50 9.95 3189 1587 1.85 / 665.41 1 1
4 7 1998.76 20 10.57 3216 680 2.53 / 666.09 1 1
5 13 1553.96 33 12.53 2545 1052 3.58 / 667.14 1 2
6 13 817.36 34 13.29 1501 678 4.26 / 667.82 1 2
7 14 -0.08 190 14.30 295 802 5.06 / 668.62 1 7
Average= 4.58 (KJ/cycle)

Cycle 144 GMT 31/ 8/2018 9: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 28 14.31 450 180 0.18 / 658.59 2 2
2 12 1128.16 4 11.60 2003 93 0.27 / 658.68 1 1
3 12 2001.00 51 9.97 3190 1622 1.90 / 660.31 1 2
4 7 1998.32 21 10.59 3222 717 2.61 / 661.02 2 1
5 13 1549.04 34 12.52 2539 1081 3.69 / 662.10 1 2
6 13 828.48 33 13.30 1510 663 4.36 / 662.77 1 3
7 14 -0.12 190 14.32 291 792 5.15 / 663.56 2 7
Average= 4.58 (KJ/cycle)

Cycle 143 GMT 21/ 8/2018 8:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 29 14.33 440 183 0.18 / 653.78 2 2
2 3 950.44 -1 14.33 440 0 0.00 / 653.78 2 2
3 12 1138.64 2 10.54 1974 42 0.22 / 653.82 1 1
4 7 2002.68 55 9.99 3207 1762 1.99 / 655.58 1 1
5 13 1802.64 33 12.24 2931 1184 3.17 / 656.77 1 2
6 13 914.16 33 13.20 1621 706 3.88 / 657.47 1 5
7 13 8.60 33 14.40 310 147 4.02 / 657.62 2 2
8 14 -0.08 190 14.29 291 790 4.81 / 658.41 2 9
Average= 4.57 (KJ/cycle)

Cycle 142 GMT 11/ 8/2018 7:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 29 14.33 447 186 0.19 / 648.92 2 2
2 12 1119.36 2 10.31 1959 40 0.23 / 648.96 1 1
3 7 2003.36 55 9.96 3211 1759 1.99 / 650.72 1 1
4 13 1809.88 34 12.20 2951 1224 3.21 / 651.94 1 2
5 13 911.92 33 13.19 1619 705 3.91 / 652.65 1 3
6 13 19.68 33 14.36 330 156 4.07 / 652.80 1 2
7 14 -0.16 190 14.30 292 793 4.86 / 653.60 2 12
Average= 4.57 (KJ/cycle)

Cycle 141 GMT 1/ 8/2018 6:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 28 14.34 444 178 0.18 / 644.37 2 2
2 3 1019.68 1 11.94 1868 22 0.20 / 644.39 1 2
3 12 1130.16 2 10.36 1986 41 0.24 / 644.43 1 1
4 7 2001.28 55 10.14 3198 1784 2.03 / 646.21 1 2
5 13 1616.40 33 12.47 2618 1077 3.10 / 647.29 1 2
6 13 779.80 33 13.32 1464 644 3.75 / 647.94 1 3
7 14 0.12 190 14.32 293 797 4.54 / 648.73 1 4
Average= 4.57 (KJ/cycle)

Cycle 140 GMT 22/ 7/2018 6:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 28 14.30 450 180 0.18 / 639.78 1 2
2 12 1112.24 2 10.59 1954 41 0.22 / 639.82 1 1
3 7 2000.96 55 9.99 3199 1758 1.98 / 641.58 1 2
4 13 1615.28 33 12.44 2644 1085 3.06 / 642.66 1 1
5 13 959.84 33 13.14 1693 734 3.80 / 643.39 1 3
6 14 0.04 190 14.32 292 794 4.59 / 644.19 2 6
Average= 4.57 (KJ/cycle)

Cycle 139 GMT 12/ 7/2018 5:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 28 14.35 426 171 0.17 / 635.15 2 2
2 12 1097.20 2 10.13 1941 39 0.21 / 635.19 1 1
3 7 2000.72 54 10.04 3208 1739 1.95 / 636.93 1 1
4 13 1609.60 33 12.46 2605 1071 3.02 / 638.00 1 2
5 13 769.92 34 13.35 1425 647 3.67 / 638.65 1 3
6 13 14.60 34 14.40 319 156 3.82 / 638.80 2 2
7 14 -0.04 190 14.27 293 794 4.62 / 639.60 2 6
Average= 4.57 (KJ/cycle)

Cycle 138 GMT 2/ 7/2018 4:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 28 14.32 446 179 0.18 / 630.31 2 2
2 12 1111.76 2 10.62 1943 41 0.22 / 630.35 1 2
3 7 2006.04 55 10.08 3205 1777 2.00 / 632.13 2 2
4 13 1807.92 33 12.21 2947 1187 3.18 / 633.32 1 2
5 13 902.20 33 13.21 1609 701 3.89 / 634.02 1 3
6 13 39.36 33 14.34 358 169 4.06 / 634.19 2 2
7 14 -0.24 190 14.32 290 789 4.84 / 634.98 2 4
Average= 4.57 (KJ/cycle)

Cycle 137 GMT 22/ 6/2018 3:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 28 14.35 428 172 0.17 / 625.46 2 2
2 12 1105.32 2 10.40 1963 41 0.21 / 625.50 1 1
3 7 2001.96 55 10.12 3195 1778 1.99 / 627.28 1 2
4 13 1811.32 33 12.21 2946 1187 3.18 / 628.46 1 2
5 13 916.96 33 13.16 1663 722 3.90 / 629.19 1 5
6 13 19.64 33 14.38 326 155 4.06 / 629.34 1 2
7 14 -0.08 191 14.32 290 793 4.85 / 630.13 2 12
Average= 4.57 (KJ/cycle)

Cycle 136 GMT 12/ 6/2018 2:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 28 14.35 427 172 0.17 / 620.73 2 2
2 12 1112.12 2 10.39 1981 41 0.21 / 620.77 1 2
3 7 2004.72 54 10.16 3221 1767 1.98 / 622.53 2 2
4 13 1621.84 33 12.45 2647 1088 3.07 / 623.62 1 2
5 13 949.96 33 13.15 1683 730 3.80 / 624.35 1 4
6 13 20.96 33 14.39 325 154 3.95 / 624.51 1 2
7 14 -0.04 190 14.33 286 779 4.73 / 625.29 1 7
Average= 4.56 (KJ/cycle)

Cycle 135 GMT 2/ 6/2018 1:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 29 14.37 434 181 0.18 / 615.91 2 2
2 3 972.84 -1 14.37 434 0 0.00 / 615.91 2 2
3 3 1043.68 1 12.31 1889 23 0.20 / 615.94 1 2
4 12 1143.12 2 11.00 1994 44 0.25 / 615.98 1 1
5 7 2003.24 55 10.29 3210 1817 2.06 / 617.80 1 2
6 13 1618.08 33 12.45 2650 1089 3.15 / 618.89 1 3
7 13 958.08 33 13.15 1698 737 3.89 / 619.62 1 4
8 13 5.96 33 14.40 305 145 4.04 / 619.77 1 2
9 14 -0.04 190 14.29 290 787 4.82 / 620.55 2 8
Average= 4.56 (KJ/cycle)

Cycle 134 GMT 23/ 5/2018 0:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 29 14.32 434 180 0.18 / 611.08 2 2
2 3 971.60 -1 14.32 434 0 0.00 / 611.08 2 2
3 3 1045.36 1 12.28 1878 23 0.20 / 611.10 1 1
4 12 1138.36 2 10.95 2011 44 0.25 / 611.14 1 2
5 7 2002.12 55 10.33 3220 1829 2.08 / 612.97 2 1
6 13 1578.60 34 12.48 2586 1097 3.17 / 614.07 1 2
7 13 902.28 33 13.20 1629 710 3.88 / 614.78 1 3
8 13 32.68 33 14.34 350 166 4.05 / 614.95 1 2
9 14 -0.20 190 14.30 289 785 4.83 / 615.73 2 12
Average= 4.56 (KJ/cycle)

Cycle 133 GMT 13/ 5/2018 0:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 29 14.33 446 185 0.19 / 606.28 2 2
2 12 1120.20 2 11.26 1969 44 0.23 / 606.33 1 1
3 7 2004.28 54 10.26 3220 1784 2.01 / 608.11 1 2
4 13 1616.00 34 12.45 2602 1101 3.12 / 609.21 1 1
5 13 935.00 34 13.15 1655 740 3.86 / 609.95 1 2
6 13 19.16 34 14.37 325 159 4.01 / 610.11 1 2
7 14 -0.12 190 14.25 290 785 4.80 / 610.90 2 8
Average= 4.56 (KJ/cycle)

Cycle 132 GMT 2/ 5/2018 23:25: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 29 14.36 436 182 0.18 / 601.70 2 2
2 12 1109.16 2 10.90 1946 42 0.22 / 601.75 1 1
3 7 2001.64 55 10.32 3211 1823 2.05 / 603.57 1 2
4 13 1615.24 34 12.44 2645 1119 3.17 / 604.69 1 1
5 13 751.28 33 13.37 1397 616 3.78 / 605.30 1 2
6 14 -0.12 190 14.30 292 793 4.58 / 606.10 2 7
Average= 4.56 (KJ/cycle)

Cycle 131 GMT 22/ 4/2018 22:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 29 14.37 434 181 0.18 / 596.98 2 2
2 12 1111.04 2 10.84 1982 43 0.22 / 597.02 1 1
3 7 2002.08 54 10.42 3219 1811 2.04 / 598.84 1 2
4 13 1621.88 33 12.47 2614 1076 3.11 / 599.91 1 3
5 13 755.40 34 13.36 1406 639 3.75 / 600.55 1 2
6 13 47.08 34 14.30 376 183 3.93 / 600.73 1 2
7 14 -0.16 190 14.29 291 790 4.72 / 601.52 2 11
Average= 4.56 (KJ/cycle)

Cycle 130 GMT 12/ 4/2018 20:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 28 14.37 434 175 0.17 / 592.04 2 2
2 3 1024.68 1 11.98 1857 22 0.20 / 592.06 1 1
3 12 1130.92 2 11.09 2001 44 0.24 / 592.10 1 1
4 7 2001.04 55 10.41 3229 1849 2.09 / 593.95 1 1
5 13 1804.44 34 12.22 2960 1230 3.32 / 595.18 1 2
6 13 877.32 33 13.24 1560 682 4.00 / 595.86 1 3
7 13 15.92 33 14.38 320 152 4.15 / 596.02 1 2
8 14 0.00 190 14.26 290 786 4.94 / 596.80 2 7
Average= 4.56 (KJ/cycle)

Cycle 129 GMT 2/ 4/2018 20:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 28 14.38 427 172 0.17 / 587.16 1 2
2 12 1123.60 2 11.00 1957 43 0.21 / 587.21 1 1
3 7 2003.44 54 10.40 3212 1804 2.02 / 589.01 1 2
4 13 1804.52 33 12.23 2931 1183 3.20 / 590.19 1 2
5 13 865.00 33 13.24 1554 679 3.88 / 590.87 1 2
6 13 68.64 33 14.28 410 193 4.07 / 591.07 1 2
7 14 -0.12 190 14.29 293 796 4.87 / 591.86 2 10
Average= 4.55 (KJ/cycle)

Cycle 128 GMT 23/ 3/2018 19:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 29 14.34 438 182 0.18 / 582.32 2 2
2 3 960.52 -1 14.34 438 0 0.00 / 582.32 2 2
3 3 1032.40 1 11.95 1874 22 0.20 / 582.35 1 1
4 12 1142.20 2 11.13 2002 45 0.25 / 582.39 1 1
5 7 2002.20 54 10.47 3222 1822 2.07 / 584.21 1 2
6 13 1609.84 33 12.44 2622 1076 3.15 / 585.29 1 2
7 13 938.64 34 13.18 1646 738 3.88 / 586.03 1 3
8 13 36.84 34 14.33 357 174 4.06 / 586.20 1 2
9 14 -0.16 190 14.28 292 792 4.85 / 586.99 1 11
Average= 4.55 (KJ/cycle)

Cycle 127 GMT 13/ 3/2018 18:28: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 29 14.36 437 182 0.18 / 577.61 2 2
2 12 1123.40 2 10.91 1975 43 0.23 / 577.66 1 1
3 7 2004.20 54 10.41 3230 1816 2.04 / 579.47 1 2
4 13 1615.12 34 12.43 2638 1115 3.16 / 580.59 1 2
5 13 719.40 34 13.41 1337 610 3.77 / 581.20 1 5
6 13 19.92 34 14.36 330 161 3.93 / 581.36 2 2
7 14 0.04 190 14.28 289 784 4.71 / 582.14 1 10
Average= 4.55 (KJ/cycle)

Cycle 126 GMT 3/ 3/2018 17:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 29 14.31 441 183 0.18 / 572.86 2 2
2 12 1109.36 2 11.04 1959 43 0.23 / 572.90 1 1
3 7 2004.76 54 10.46 3227 1823 2.05 / 574.72 1 1
4 13 1605.20 34 12.45 2621 1109 3.16 / 575.83 1 2
5 13 747.04 34 13.37 1414 643 3.80 / 576.47 1 2
6 13 22.08 34 14.35 337 164 3.97 / 576.64 1 2
7 14 -0.08 190 14.27 292 792 4.76 / 577.43 1 9
Average= 4.55 (KJ/cycle)

Cycle 125 GMT 21/ 2/2018 16:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 29 14.34 437 182 0.18 / 568.19 2 2
2 12 1121.40 2 11.25 1962 44 0.23 / 568.24 1 2
3 7 2002.52 55 10.50 3223 1861 2.09 / 570.10 2 2
4 13 1441.52 33 12.64 2337 975 3.06 / 571.07 1 2
5 13 807.92 33 13.32 1452 638 3.70 / 571.71 1 3
6 13 31.00 33 14.33 353 167 3.87 / 571.88 1 2
7 14 -0.20 190 14.27 293 794 4.66 / 572.67 1 10
Average= 4.55 (KJ/cycle)

Cycle 124 GMT 11/ 2/2018 16: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 28 14.39 436 176 0.18 / 563.63 2 2
2 12 1125.56 2 11.04 1976 44 0.22 / 563.67 1 1
3 7 2002.52 54 10.54 3227 1837 2.06 / 565.51 1 1
4 13 1594.88 34 12.47 2605 1104 3.16 / 566.62 1 2
5 13 701.72 34 13.43 1327 606 3.77 / 567.22 1 3
6 14 -0.04 190 14.29 291 790 4.56 / 568.01 2 6
Average= 4.54 (KJ/cycle)

Cycle 123 GMT 1/ 2/2018 15:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 28 14.35 435 175 0.17 / 558.78 2 2
2 12 1111.24 2 11.00 1942 43 0.22 / 558.83 1 2
3 7 2003.08 55 10.51 3226 1865 2.08 / 560.69 2 2
4 13 1595.52 34 12.45 2614 1107 3.19 / 561.80 1 2
5 13 909.08 33 13.21 1612 703 3.89 / 562.50 1 3
6 13 38.56 33 14.34 359 170 4.06 / 562.67 2 2
7 14 -0.20 190 14.30 289 785 4.85 / 563.46 2 9
Average= 4.54 (KJ/cycle)

Cycle 122 GMT 22/ 1/2018 14:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 28 14.33 437 175 0.18 / 554.03 2 2
2 12 1130.32 2 11.10 1989 44 0.22 / 554.08 1 1
3 7 2011.20 55 10.58 3231 1880 2.10 / 555.96 1 2
4 13 1596.68 33 12.46 2617 1076 3.18 / 557.03 1 2
5 13 737.92 33 13.39 1389 614 3.79 / 557.65 1 2
6 13 45.52 33 14.32 372 176 3.97 / 557.82 2 2
7 14 -0.04 190 14.30 290 788 4.75 / 558.61 2 12
Average= 4.54 (KJ/cycle)

Cycle 121 GMT 12/ 1/2018 13:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 29 14.36 425 177 0.18 / 549.44 2 2
2 3 943.88 -1 14.36 425 0 0.00 / 549.44 2 2
3 12 1129.56 2 10.73 2010 43 0.22 / 549.48 1 1
4 7 2002.84 55 10.61 3218 1878 2.10 / 551.36 1 1
5 13 1598.04 34 12.48 2608 1107 3.20 / 552.46 1 2
6 13 724.00 33 13.41 1356 600 3.80 / 553.06 1 4
7 14 -0.04 190 14.29 292 793 4.60 / 553.86 1 8
Average= 4.54 (KJ/cycle)

Cycle 120 GMT 2/ 1/2018 12:50: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 29 14.35 440 183 0.18 / 544.60 2 2
2 12 1105.08 2 10.92 1962 43 0.23 / 544.65 1 2
3 7 2001.44 55 10.58 3231 1880 2.11 / 546.53 2 2
4 13 1606.72 33 12.43 2637 1082 3.19 / 547.61 1 2
5 13 903.80 33 13.20 1620 706 3.89 / 548.31 1 4
6 13 13.44 33 14.38 322 153 4.05 / 548.47 1 2
7 14 -0.12 190 14.24 293 793 4.84 / 549.26 2 11
Average= 4.54 (KJ/cycle)

Cycle 119 GMT 23/12/2017 12:18:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 28 14.38 441 178 0.18 / 540.00 2 2
2 3 1027.04 1 12.05 1873 23 0.20 / 540.02 1 2
3 12 1130.92 2 11.24 1978 44 0.24 / 540.06 1 1
4 7 2002.12 54 10.66 3234 1862 2.11 / 541.93 1 1
5 13 1601.92 33 12.47 2625 1080 3.19 / 543.01 1 1
6 13 738.76 33 13.37 1407 621 3.81 / 543.63 1 4
7 14 -0.16 190 14.30 292 793 4.60 / 544.42 1 7
Average= 4.54 (KJ/cycle)

Cycle 118 GMT 13/12/2017 11:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 28 14.33 449 180 0.18 / 535.56 2 2
2 12 1121.60 2 11.06 1981 44 0.22 / 535.61 1 2
3 7 2006.44 54 10.67 3242 1868 2.09 / 537.47 2 1
4 13 1425.72 34 12.66 2351 1012 3.10 / 538.49 1 1
5 13 586.28 34 13.57 1172 541 3.64 / 539.03 1 3
6 14 0.00 190 14.29 292 793 4.44 / 539.82 2 7
Average= 4.54 (KJ/cycle)

Cycle 117 GMT 3/12/2017 10:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 28 14.34 437 175 0.18 / 530.87 1 2
2 12 1127.80 2 11.10 1993 44 0.22 / 530.92 1 1
3 7 2002.08 54 10.76 3228 1876 2.10 / 532.79 1 1
4 13 1585.76 33 12.49 2594 1069 3.16 / 533.86 1 2
5 13 703.12 33 13.45 1321 586 3.75 / 534.45 1 5
6 13 1.52 33 14.43 301 143 3.89 / 534.59 2 2
7 14 -0.04 190 14.26 291 788 4.68 / 535.38 2 13
Average= 4.54 (KJ/cycle)

Cycle 116 GMT 23/11/2017 9:26: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 28 14.34 444 178 0.18 / 526.31 1 2
2 3 963.52 -1 14.34 444 0 0.00 / 526.31 1 2
3 3 1034.64 1 12.13 1886 23 0.20 / 526.33 1 2
4 12 1138.40 2 10.80 2028 44 0.24 / 526.37 1 1
5 7 2001.36 54 10.79 3233 1884 2.13 / 528.26 1 2
6 13 1585.72 33 12.53 2557 1057 3.19 / 529.31 1 2
7 13 709.36 33 13.45 1325 588 3.77 / 529.90 1 4
8 14 -0.12 190 14.28 294 798 4.57 / 530.70 2 6
Average= 4.54 (KJ/cycle)

Cycle 115 GMT 13/11/2017 8:51: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 28 14.36 450 181 0.18 / 521.51 1 2
2 12 1124.56 2 11.13 1998 44 0.23 / 521.55 1 1
3 7 2004.52 55 10.81 3242 1928 2.15 / 523.48 1 2
4 13 1600.48 34 12.50 2601 1105 3.26 / 524.58 1 2
5 13 709.80 33 13.43 1341 594 3.85 / 525.18 1 6
6 13 3.60 33 14.40 311 148 4.00 / 525.33 1 2
7 14 -0.04 190 14.23 296 800 4.80 / 526.13 2 11
Average= 4.54 (KJ/cycle)

Cycle 114 GMT 3/11/2017 8: 2: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 28 14.34 455 183 0.18 / 516.88 2 2
2 12 1114.32 2 11.16 1959 44 0.23 / 516.93 1 2
3 7 2002.32 54 10.80 3249 1895 2.12 / 518.82 2 2
4 13 1592.16 34 12.51 2591 1102 3.22 / 519.93 1 2
5 13 702.12 34 13.45 1315 601 3.82 / 520.53 1 4
6 14 0.00 190 14.27 295 800 4.62 / 521.33 2 6
Average= 4.53 (KJ/cycle)

Cycle 113 GMT 24/10/2017 6:55: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 27 14.35 454 176 0.18 / 512.20 2 2
2 3 1027.08 1 12.12 1858 23 0.20 / 512.22 1 2
3 12 1124.96 2 11.05 1986 44 0.24 / 512.26 1 1
4 7 2001.52 55 10.92 3226 1938 2.18 / 514.20 1 2
5 13 1592.32 34 12.51 2610 1110 3.29 / 515.31 1 2
6 13 704.00 33 13.45 1328 589 3.88 / 515.90 1 3
7 14 0.04 190 14.27 295 800 4.68 / 516.70 2 8
Average= 4.53 (KJ/cycle)

Cycle 112 GMT 14/10/2017 5:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 27 14.36 449 174 0.17 / 507.59 2 2
2 12 1120.48 2 11.28 1973 45 0.22 / 507.63 1 1
3 7 2000.96 55 10.94 3221 1938 2.16 / 509.57 1 2
4 13 1597.76 33 12.51 2596 1072 3.23 / 510.64 1 1
5 13 709.76 33 13.44 1336 593 3.82 / 511.23 1 2
6 14 -0.36 190 14.28 291 790 4.61 / 512.02 2 5
Average= 4.53 (KJ/cycle)

Cycle 111 GMT 4/10/2017 5: 6: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 27 14.36 449 174 0.17 / 502.97 2 2
2 12 1114.20 2 11.15 1961 44 0.22 / 503.01 1 1
3 7 2000.36 55 10.86 3236 1933 2.15 / 504.94 1 1
4 13 1593.36 33 12.53 2589 1071 3.22 / 506.01 1 3
5 13 697.88 33 13.45 1334 592 3.81 / 506.60 1 4
6 14 0.12 190 14.26 298 807 4.62 / 507.41 1 7
Average= 4.53 (KJ/cycle)

Cycle 110 GMT 24/ 9/2017 3:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 28 14.35 453 182 0.18 / 498.02 2 2
2 3 972.48 -1 14.35 453 0 0.00 / 498.02 2 2
3 12 1149.16 2 11.53 2015 46 0.23 / 498.07 1 1
4 7 2003.60 55 10.95 3229 1945 2.17 / 500.01 1 1
5 13 1604.88 33 12.52 2613 1080 3.25 / 501.09 1 2
6 13 714.92 33 13.43 1339 593 3.85 / 501.69 1 2
7 13 22.20 33 14.37 335 159 4.01 / 501.85 1 2
8 13 13.80 33 14.27 322 152 4.16 / 502.00 2 2
9 14 -0.12 190 14.20 294 793 4.95 / 502.79 2 18
Average= 4.53 (KJ/cycle)

Cycle 109 GMT 14/ 9/2017 2:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 28 14.30 463 185 0.19 / 493.36 1 2
2 12 1102.84 2 11.05 1958 43 0.23 / 493.40 1 2
3 7 2001.96 54 10.85 3240 1898 2.13 / 495.30 2 1
4 13 1602.08 34 12.52 2612 1112 3.24 / 496.41 1 2
5 13 737.00 34 13.41 1368 624 3.86 / 497.04 1 3
6 14 -0.16 190 14.26 297 805 4.67 / 497.84 1 7
Average= 4.53 (KJ/cycle)

Cycle 108 GMT 4/ 9/2017 1:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 28 14.32 448 180 0.18 / 488.79 2 2
2 12 1097.72 2 10.72 1950 42 0.22 / 488.84 1 1
3 7 2005.28 55 10.85 3251 1940 2.16 / 490.78 1 2
4 13 1418.40 33 12.70 2349 984 3.15 / 491.76 1 3
5 13 755.12 33 13.41 1391 616 3.76 / 492.38 1 3
6 14 -0.04 190 14.28 294 798 4.56 / 493.17 1 5
Average= 4.52 (KJ/cycle)

Cycle 107 GMT 25/ 8/2017 0:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 28 14.39 449 181 0.18 / 484.24 2 2
2 3 960.80 -1 14.39 449 0 0.00 / 484.24 2 2
3 3 1043.40 1 12.38 1893 23 0.20 / 484.27 1 2
4 12 1131.32 2 11.34 1984 45 0.25 / 484.31 1 1
5 7 2004.12 54 10.97 3240 1919 2.17 / 486.23 1 1
6 13 1416.16 33 12.72 2327 977 3.15 / 487.21 1 1
7 13 751.64 33 13.43 1380 612 3.76 / 487.82 1 2
8 14 -0.08 190 14.27 294 797 4.55 / 488.62 2 5
Average= 4.52 (KJ/cycle)

Cycle 106 GMT 14/ 8/2017 23:37:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 28 14.43 431 174 0.17 / 479.46 2 2
2 12 1091.00 2 10.84 1933 42 0.22 / 479.50 1 1
3 7 2003.56 54 10.96 3238 1916 2.13 / 481.42 1 2
4 13 1602.64 33 12.55 2611 1081 3.21 / 482.50 1 2
5 13 701.24 34 13.47 1337 612 3.83 / 483.11 1 2
6 13 19.76 34 14.40 329 161 3.99 / 483.27 2 1
7 14 0.00 190 14.23 291 787 4.77 / 484.06 2 12
Average= 4.52 (KJ/cycle)

Cycle 105 GMT 4/ 8/2017 22:39: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 28 14.40 447 180 0.18 / 474.84 2 2
2 12 1110.96 2 11.22 1957 44 0.22 / 474.88 1 2
3 7 2003.32 54 11.06 3236 1933 2.16 / 476.81 2 1
4 13 1595.20 34 12.60 2545 1090 3.25 / 477.90 1 2
5 13 703.32 34 13.50 1300 597 3.84 / 478.50 1 2
6 14 0.12 190 14.30 290 788 4.63 / 479.29 1 4
Average= 4.52 (KJ/cycle)

Cycle 104 GMT 25/ 7/2017 21:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 28 14.43 437 177 0.18 / 470.17 2 2
2 12 1108.52 2 11.34 1967 45 0.22 / 470.22 1 1
3 7 2002.24 54 11.02 3242 1929 2.15 / 472.15 1 2
4 13 1596.56 34 12.56 2585 1104 3.25 / 473.25 1 2
5 13 706.60 34 13.46 1351 618 3.87 / 473.87 1 4
6 14 -0.12 190 14.29 290 787 4.66 / 474.66 2 6
Average= 4.52 (KJ/cycle)

Cycle 103 GMT 15/ 7/2017 21: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 27 14.40 457 178 0.18 / 465.72 2 2
2 3 1028.60 1 12.43 1853 23 0.20 / 465.75 1 2
3 12 1145.64 2 11.52 2034 47 0.25 / 465.79 1 2
4 7 2001.40 54 11.07 3244 1939 2.19 / 467.73 2 2
5 13 1403.32 33 12.75 2316 974 3.16 / 468.71 1 2
6 13 548.40 33 13.67 1111 501 3.66 / 469.21 1 2
7 14 -0.16 190 14.31 289 786 4.45 / 470.00 2 6
Average= 4.52 (KJ/cycle)

Cycle 102 GMT 5/ 7/2017 19:56: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 27 14.39 437 170 0.17 / 461.24 1 2
2 12 1114.72 2 11.85 1972 47 0.22 / 461.29 1 2
3 7 2002.44 55 11.09 3238 1975 2.19 / 463.26 2 1
4 13 1409.52 33 12.76 2323 978 3.17 / 464.24 1 1
5 13 548.24 33 13.67 1110 501 3.67 / 464.74 1 2
6 14 -0.16 190 14.27 297 805 4.48 / 465.55 2 7
Average= 4.52 (KJ/cycle)

Cycle 101 GMT 25/ 6/2017 18:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 28 14.44 442 179 0.18 / 456.60 2 2
2 3 972.72 -1 14.44 442 0 0.00 / 456.60 2 2
3 12 1147.52 2 11.44 2023 46 0.22 / 456.65 1 2
4 7 2002.24 55 11.09 3242 1977 2.20 / 458.63 2 1
5 13 1590.48 33 12.59 2590 1076 3.28 / 459.70 1 2
6 13 681.72 33 13.51 1270 566 3.84 / 460.27 1 2
7 14 -0.04 190 14.28 296 803 4.65 / 461.07 2 5
Average= 4.52 (KJ/cycle)

Cycle 100 GMT 15/ 6/2017 17:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 28 14.46 433 175 0.18 / 451.93 2 2
2 12 1097.80 2 10.63 1926 41 0.22 / 451.97 1 1
3 7 2011.56 54 11.04 3247 1936 2.15 / 453.90 1 2
4 13 1583.04 34 12.59 2583 1106 3.26 / 455.01 1 2
5 13 698.64 34 13.49 1332 611 3.87 / 455.62 1 4
6 14 -0.04 190 14.28 296 803 4.67 / 456.42 2 7
Average= 4.52 (KJ/cycle)

Cycle 99 GMT 5/ 6/2017 15:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 28 14.48 426 173 0.17 / 447.27 2 2
2 3 970.80 -1 14.48 426 0 0.00 / 447.27 2 2
3 3 1041.68 1 12.65 1885 24 0.20 / 447.29 1 2
4 12 1142.80 2 11.07 2014 45 0.24 / 447.34 1 2
5 7 2001.28 54 11.02 3227 1920 2.16 / 449.26 2 2
6 13 1584.80 34 12.57 2587 1106 3.27 / 450.36 1 3
7 13 692.44 34 13.51 1307 600 3.87 / 450.96 1 2
8 14 -0.04 190 14.31 290 788 4.66 / 451.75 2 9
Average= 4.52 (KJ/cycle)

Cycle 98 GMT 26/ 5/2017 15: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 27 14.45 434 169 0.17 / 443.05 2 2
2 3 1021.60 1 11.49 1857 21 0.19 / 443.07 1 1
3 3 1022.84 1 11.67 1857 22 0.21 / 443.09 1 2
4 12 1133.48 2 10.80 2001 43 0.26 / 443.14 1 2
5 7 1727.16 54 11.37 2859 1755 2.01 / 444.89 2 1
6 13 1341.40 33 12.83 2220 940 2.95 / 445.83 1 2
7 13 488.00 33 13.75 1047 475 3.43 / 446.31 1 2
8 14 0.04 190 14.32 290 789 4.21 / 447.10 2 10
Average= 4.52 (KJ/cycle)

Cycle 97 GMT 16/ 5/2017 13:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 27 14.50 422 165 0.17 / 438.31 2 2
2 12 1126.28 2 11.47 1989 46 0.21 / 438.36 1 2
3 7 1994.16 55 11.09 3225 1967 2.18 / 440.32 2 1
4 13 1584.88 33 12.62 2570 1070 3.25 / 441.40 1 2
5 13 887.52 33 13.31 1581 694 3.94 / 442.09 1 2
6 14 -0.24 190 14.31 291 791 4.73 / 442.88 2 4
Average= 4.52 (KJ/cycle)

Cycle 96 GMT 6/ 5/2017 11:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 27 14.48 432 169 0.17 / 433.62 2 2
2 12 1133.44 2 10.88 1976 43 0.21 / 433.66 1 1
3 7 2004.36 55 11.10 3246 1982 2.19 / 435.64 1 2
4 13 1397.44 33 12.80 2306 974 3.17 / 436.62 1 4
5 13 724.96 33 13.48 1354 602 3.77 / 437.22 1 2
6 13 2.48 33 14.48 299 143 3.91 / 437.36 1 2
7 14 -0.16 190 14.27 290 786 4.70 / 438.15 2 16
Average= 4.52 (KJ/cycle)

Cycle 95 GMT 26/ 4/2017 10: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 28 14.45 428 173 0.17 / 429.04 2 2
2 3 958.56 -1 14.45 428 0 0.00 / 429.04 2 2
3 3 1027.96 1 12.43 1856 23 0.20 / 429.06 1 4
4 12 1141.96 2 11.26 2032 46 0.24 / 429.11 1 1
5 7 2000.40 54 11.19 3249 1963 2.21 / 431.07 1 2
6 13 1389.56 34 12.84 2250 982 3.19 / 432.05 1 3
7 13 707.60 34 13.53 1292 594 3.78 / 432.65 1 2
8 14 -0.08 190 14.29 295 801 4.58 / 433.45 2 6
Average= 4.52 (KJ/cycle)

Cycle 94 GMT 16/ 4/2017 9: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 28 14.49 426 173 0.17 / 424.26 2 2
2 3 969.96 -1 14.49 426 0 0.00 / 424.26 2 2
3 3 1039.28 1 12.70 1874 24 0.20 / 424.28 1 2
4 12 1141.28 2 11.39 2043 47 0.24 / 424.33 1 1
5 7 2001.20 54 11.18 3250 1962 2.21 / 426.29 1 2
6 13 1577.28 33 12.63 2567 1070 3.28 / 427.36 1 3
7 13 661.96 33 13.55 1263 565 3.84 / 427.92 1 3
8 13 7.96 33 14.43 312 149 3.99 / 428.07 1 2
9 14 -0.24 190 14.24 293 793 4.78 / 428.87 2 10
Average= 4.51 (KJ/cycle)

Cycle 93 GMT 6/ 4/2017 8: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 28 14.52 426 173 0.17 / 419.72 2 2
2 12 1098.32 2 10.91 1953 43 0.22 / 419.77 1 2
3 7 2000.68 54 11.14 3234 1945 2.16 / 421.71 2 2
4 13 1402.52 33 12.80 2311 976 3.14 / 422.69 1 2
5 13 730.80 33 13.47 1364 606 3.74 / 423.30 1 3
6 14 -0.16 190 14.31 290 788 4.53 / 424.08 2 16
Average= 4.51 (KJ/cycle)

Cycle 92 GMT 27/ 3/2017 6:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 28 14.50 434 176 0.18 / 415.14 2 2
2 12 1109.24 2 10.24 1944 40 0.22 / 415.18 1 1
3 7 2003.24 55 11.12 3244 1984 2.20 / 417.17 1 2
4 13 1418.76 33 12.80 2340 988 3.19 / 418.16 1 2
5 13 751.68 33 13.46 1388 617 3.80 / 418.77 1 2
6 14 -0.04 190 14.34 286 779 4.58 / 419.55 2 5
Average= 4.51 (KJ/cycle)

Cycle 91 GMT 17/ 3/2017 5: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 28 14.50 427 173 0.17 / 410.52 2 2
2 12 1096.32 2 9.71 1932 38 0.21 / 410.56 1 1
3 7 2001.76 54 11.07 3233 1933 2.14 / 412.49 1 1
4 13 1573.08 34 12.64 2559 1100 3.24 / 413.59 1 2
5 13 681.04 34 13.56 1278 589 3.83 / 414.18 1 2
6 14 -0.16 190 14.33 289 787 4.62 / 414.97 2 6
Average= 4.51 (KJ/cycle)

Cycle 90 GMT 7/ 3/2017 3:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 28 14.56 422 172 0.17 / 406.35 2 2
2 12 1112.36 2 10.42 1959 41 0.21 / 406.39 1 1
3 7 1536.68 55 11.61 2567 1639 1.85 / 408.03 1 2
4 13 1353.12 33 12.81 2217 937 2.79 / 408.97 1 2
5 13 436.84 33 13.85 956 437 3.23 / 409.40 1 2
6 13 11.12 33 14.47 315 150 3.38 / 409.55 1 2
7 14 -0.16 190 14.25 293 793 4.17 / 410.35 2 14
Average= 4.51 (KJ/cycle)

Cycle 89 GMT 25/ 2/2017 3: 9: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 28 14.55 437 178 0.18 / 402.30 2 2
2 12 1119.92 2 9.46 1969 37 0.22 / 402.34 1 1
3 7 1624.12 55 11.50 2705 1711 1.93 / 404.05 1 2
4 13 1239.16 34 12.95 2061 907 2.83 / 404.96 1 2
5 13 381.20 34 13.94 884 419 3.25 / 405.38 1 2
6 14 -0.16 190 14.32 294 800 4.05 / 406.18 1 7
Average= 4.51 (KJ/cycle)

Cycle 88 GMT 15/ 2/2017 2: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 28 14.55 428 174 0.17 / 398.21 2 2
2 12 1132.56 2 9.84 1964 39 0.21 / 398.25 1 1
3 7 1545.44 55 11.54 2587 1642 1.85 / 399.89 1 2
4 13 1352.72 34 12.80 2258 983 2.84 / 400.87 1 3
5 13 460.84 33 13.82 1003 457 3.30 / 401.33 1 2
6 14 0.00 190 14.34 292 796 4.09 / 402.13 2 10
Average= 4.52 (KJ/cycle)

Cycle 87 GMT 5/ 2/2017 1: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 28 14.53 427 174 0.17 / 394.34 2 2
2 12 1108.96 2 9.10 1930 35 0.21 / 394.37 1 2
3 7 1561.20 54 11.48 2618 1623 1.83 / 396.00 2 2
4 13 1195.60 33 12.99 2032 871 2.70 / 396.87 1 2
5 13 342.00 33 14.01 823 380 3.08 / 397.25 1 2
6 14 0.00 190 14.35 289 788 3.87 / 398.04 2 9
Average= 4.52 (KJ/cycle)

Cycle 86 GMT 25/ 1/2017 23:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 28 14.53 427 174 0.17 / 389.68 2 2
2 3 973.44 -1 14.53 427 0 0.00 / 389.68 2 2
3 3 1051.72 1 12.90 1899 24 0.20 / 389.70 1 1
4 12 1144.56 2 10.35 1985 41 0.24 / 389.74 1 2
5 7 2004.52 54 11.09 3241 1941 2.18 / 391.68 2 2
6 13 1418.08 33 12.86 2337 992 3.17 / 392.68 1 2
7 13 576.52 34 13.74 1132 529 3.70 / 393.20 1 3
8 13 20.76 34 14.46 332 163 3.86 / 393.37 2 2
9 14 -0.20 190 14.29 293 796 4.66 / 394.16 1 12
Average= 4.53 (KJ/cycle)

Cycle 85 GMT 15/ 1/2017 22:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 28 14.52 434 176 0.18 / 384.92 2 2
2 12 1098.48 2 9.59 1919 37 0.21 / 384.96 1 1
3 7 2005.08 54 11.04 3232 1927 2.14 / 386.89 1 2
4 13 1412.96 34 12.85 2359 1031 3.17 / 387.92 1 2
5 13 738.96 34 13.52 1374 632 3.80 / 388.55 1 3
6 13 16.32 33 14.45 327 156 3.96 / 388.70 2 2
7 14 -0.16 190 14.23 296 800 4.76 / 389.50 2 10
Average= 4.53 (KJ/cycle)

Cycle 84 GMT 5/ 1/2017 21:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 28 14.53 435 177 0.18 / 380.25 2 2
2 3 957.92 -1 14.53 435 0 0.00 / 380.25 2 2
3 3 1033.80 1 12.77 1863 24 0.20 / 380.28 1 2
4 12 1133.28 2 9.64 1977 38 0.24 / 380.32 1 1
5 7 2001.84 54 11.06 3239 1934 2.17 / 382.25 1 2
6 13 1370.04 33 12.95 2221 949 3.12 / 383.20 1 2
7 13 701.52 34 13.61 1291 597 3.72 / 383.80 1 2
8 13 2.72 34 14.48 305 150 3.87 / 383.95 1 2
9 14 -0.08 190 14.26 295 799 4.67 / 384.75 2 9
Average= 4.53 (KJ/cycle)

Cycle 83 GMT 26/12/2016 20:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 27 14.56 442 174 0.17 / 375.51 2 2
2 3 1040.16 1 13.27 1878 25 0.20 / 375.54 1 2
3 12 1122.56 2 11.30 1978 45 0.24 / 375.58 1 2
4 7 2002.68 54 11.10 3239 1941 2.18 / 377.52 2 1
5 13 1412.20 33 12.89 2311 983 3.17 / 378.50 1 2
6 13 730.12 33 13.57 1341 601 3.77 / 379.11 1 2
7 13 32.48 33 14.44 353 168 3.94 / 379.27 1 2
8 14 -0.12 190 14.28 296 803 4.74 / 380.08 2 9
Average= 4.52 (KJ/cycle)

Cycle 82 GMT 16/12/2016 19:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 28 14.52 449 183 0.18 / 372.73 2 2
2 3 963.72 -1 14.52 449 0 0.00 / 372.73 2 2
3 12 1057.84 2 11.31 1884 43 0.23 / 372.77 1 1
4 7 1222.96 55 12.00 2083 1375 1.60 / 374.15 1 2
5 13 351.12 33 14.00 834 385 1.99 / 374.53 1 2
6 14 -0.04 190 14.34 295 804 2.79 / 375.34 1 11
Average= 4.52 (KJ/cycle)

Cycle 81 GMT 6/12/2016 19:10:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 27 14.50 459 180 0.18 / 368.08 2 2
2 12 1119.64 2 9.89 1970 39 0.22 / 368.12 1 2
3 7 2000.84 54 11.09 3222 1930 2.15 / 370.05 2 2
4 13 1406.80 34 12.93 2311 1016 3.16 / 371.06 1 2
5 13 548.88 34 13.82 1101 517 3.68 / 371.58 1 3
6 13 19.56 34 14.48 332 163 3.84 / 371.74 2 2
7 14 -0.12 190 14.25 297 804 4.65 / 372.55 2 11
Average= 4.54 (KJ/cycle)

Cycle 80 GMT 26/11/2016 17:57: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 27 14.52 446 175 0.17 / 363.46 1 2
2 12 1110.72 2 9.60 1951 37 0.21 / 363.50 1 2
3 7 2004.20 54 11.05 3229 1927 2.14 / 365.43 2 2
4 13 1416.00 34 12.93 2337 1027 3.17 / 366.46 1 1
5 13 754.76 34 13.60 1373 635 3.80 / 367.09 1 5
6 14 0.00 190 14.32 297 808 4.61 / 367.90 2 9
Average= 4.54 (KJ/cycle)

Cycle 79 GMT 16/11/2016 17: 6: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 27 14.51 462 181 0.18 / 358.79 2 2
2 12 1127.88 2 10.68 1960 42 0.22 / 358.84 1 1
3 7 2006.16 55 11.08 3238 1973 2.20 / 360.81 1 2
4 13 1601.60 33 12.80 2583 1091 3.29 / 361.90 1 2
5 13 686.60 33 13.67 1293 583 3.87 / 362.48 1 3
6 14 0.00 190 14.32 296 805 4.68 / 363.29 2 12
Average= 4.54 (KJ/cycle)

Cycle 78 GMT 6/11/2016 15:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 27 14.51 466 183 0.18 / 354.12 2 2
2 12 1113.68 2 10.51 1970 41 0.22 / 354.16 1 2
3 7 2003.68 55 11.11 3238 1979 2.20 / 356.14 2 1
4 13 1408.48 34 13.00 2291 1013 3.22 / 357.15 1 2
5 13 743.68 34 13.61 1399 647 3.86 / 357.80 1 2
6 14 0.04 190 14.31 300 816 4.68 / 358.61 1 7
Average= 4.54 (KJ/cycle)

Cycle 77 GMT 27/10/2016 14:44: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 27 14.52 465 182 0.18 / 349.23 2 2
2 7 2007.64 51 11.11 3210 1819 2.00 / 351.05 2 2
3 13 1809.40 35 12.63 2913 1288 3.29 / 352.33 1 2
4 13 910.40 36 13.43 1599 773 4.06 / 353.11 1 2
5 14 -0.16 190 14.32 304 827 4.89 / 353.94 1 7
Average= 4.54 (KJ/cycle)

Cycle 76 GMT 17/10/2016 14:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 28 14.50 466 189 0.19 / 344.34 2 2
2 3 962.88 -1 14.50 466 0 0.00 / 344.34 2 2
3 3 1039.28 1 13.22 1870 25 0.21 / 344.36 1 2
4 7 2001.24 50 11.19 3208 1795 2.01 / 346.16 2 2
5 13 1804.96 36 12.57 2925 1324 3.33 / 347.48 1 2
6 13 900.24 35 13.45 1596 751 4.08 / 348.23 1 3
7 14 0.04 190 14.31 300 816 4.90 / 349.05 2 7
Average= 4.53 (KJ/cycle)

Cycle 75 GMT 7/10/2016 15: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 28 14.51 459 186 0.19 / 339.32 1 2
2 7 2007.96 50 11.21 3222 1806 1.99 / 341.12 2 2
3 13 1808.04 35 12.60 2908 1282 3.27 / 342.41 1 2
4 13 891.48 35 13.48 1577 744 4.02 / 343.15 1 2
5 13 32.76 35 14.47 358 181 4.20 / 343.33 1 2
6 14 -0.12 190 14.30 300 815 5.02 / 344.15 1 11
Average= 4.53 (KJ/cycle)

Cycle 74 GMT 27/ 9/2016 15: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 28 14.50 462 188 0.19 / 334.46 2 2
2 7 2007.68 51 11.24 3238 1856 2.04 / 336.31 2 2
3 13 1636.80 36 12.78 2646 1217 3.26 / 337.53 1 2
4 13 944.96 36 13.44 1635 791 4.05 / 338.32 1 3
5 14 -0.04 190 14.32 298 811 4.86 / 339.13 2 7
Average= 4.52 (KJ/cycle)

Cycle 73 GMT 17/ 9/2016 15: 3: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 27 14.53 468 184 0.18 / 329.51 2 2
2 3 1031.44 1 13.21 1880 25 0.21 / 329.53 1 2
3 7 2001.76 50 11.34 3238 1836 2.04 / 331.37 1 2
4 13 1800.92 36 12.64 2891 1316 3.36 / 332.68 1 2
5 13 899.12 36 13.46 1583 767 4.13 / 333.45 1 3
6 14 -0.12 190 14.32 301 819 4.95 / 334.27 1 4
Average= 4.52 (KJ/cycle)

Cycle 72 GMT 7/ 9/2016 15:11: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 27 14.57 446 175 0.18 / 324.64 1 2
2 7 2007.72 50 11.36 3245 1843 2.02 / 326.48 2 2
3 13 1629.52 36 12.83 2642 1220 3.24 / 327.70 1 2
4 13 930.92 36 13.44 1659 803 4.04 / 328.51 1 2
5 14 0.04 190 14.33 300 817 4.86 / 329.32 2 5
Average= 4.51 (KJ/cycle)

Cycle 71 GMT 28/ 8/2016 15:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 27 14.56 459 180 0.18 / 319.75 2 2
2 3 964.52 -1 14.56 459 0 0.00 / 319.75 2 2
3 3 1028.08 1 13.13 1897 25 0.21 / 319.77 1 2
4 7 2003.20 50 11.55 3236 1869 2.07 / 321.64 2 2
5 13 1810.04 35 12.66 2885 1278 3.35 / 322.92 1 2
6 13 876.20 35 13.53 1548 733 4.09 / 323.65 1 2
7 14 -0.16 190 14.33 298 811 4.90 / 324.46 1 5
Average= 4.51 (KJ/cycle)

Cycle 70 GMT 18/ 8/2016 15:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 26 14.58 459 174 0.17 / 314.67 2 2
2 3 1024.24 1 13.04 1875 24 0.20 / 314.70 1 2
3 7 2005.48 50 11.64 3227 1878 2.08 / 316.58 1 2
4 13 1618.68 36 12.87 2621 1214 3.29 / 317.79 1 1
5 13 934.68 36 13.47 1644 797 4.09 / 318.59 1 2
6 13 13.92 36 14.50 326 170 4.26 / 318.76 1 2
7 14 -0.12 190 14.26 299 810 5.07 / 319.57 2 11
Average= 4.50 (KJ/cycle)

Cycle 69 GMT 8/ 8/2016 15:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 26 14.58 444 168 0.17 / 309.99 2 2
2 7 2000.72 50 11.63 3219 1872 2.04 / 311.86 1 2
3 13 1629.64 35 12.90 2578 1164 3.20 / 313.03 1 2
4 13 743.56 35 13.67 1380 660 3.86 / 313.69 1 2
5 14 -0.04 190 14.35 297 810 4.67 / 314.50 1 8
Average= 4.49 (KJ/cycle)

Cycle 68 GMT 29/ 7/2016 15:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 27 14.58 446 176 0.18 / 304.85 2 2
2 3 953.56 -1 14.58 446 0 0.00 / 304.85 2 2
3 3 1020.84 1 12.43 1879 23 0.20 / 304.87 1 2
4 7 2005.96 51 11.67 3236 1926 2.12 / 306.80 2 2
5 13 1808.52 35 12.76 2896 1293 3.42 / 308.09 1 2
6 13 885.92 35 13.53 1583 750 4.17 / 308.84 1 4
7 13 28.48 36 14.49 347 181 4.35 / 309.02 1 2
8 14 -0.12 190 14.29 296 804 5.15 / 309.82 2 9
Average= 4.49 (KJ/cycle)

Cycle 67 GMT 19/ 7/2016 15:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 27 14.58 456 180 0.18 / 299.94 2 2
2 7 2002.68 50 11.76 3223 1895 2.07 / 301.83 1 2
3 13 1804.88 35 12.73 2906 1295 3.37 / 303.13 1 2
4 13 858.32 35 13.58 1529 727 4.10 / 303.86 1 2
5 14 0.04 190 14.32 300 816 4.91 / 304.67 2 16
Average= 4.48 (KJ/cycle)

Cycle 66 GMT 9/ 7/2016 15:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 27 14.60 454 179 0.18 / 295.19 2 2
2 7 2005.28 50 11.83 3235 1914 2.09 / 297.11 1 2
3 13 1600.28 36 12.97 2547 1189 3.28 / 298.30 1 3
4 13 726.20 36 13.73 1327 656 3.94 / 298.95 1 2
5 14 0.00 190 14.34 296 806 4.74 / 299.76 1 8
Average= 4.47 (KJ/cycle)

Cycle 65 GMT 29/ 6/2016 15:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 27 14.63 451 178 0.18 / 290.77 2 2
2 7 2002.64 50 11.82 3236 1912 2.09 / 292.69 2 2
3 13 1438.96 22 13.27 2365 690 2.78 / 293.38 1 1
4 13 1036.84 22 13.59 1803 539 3.32 / 293.92 1 2
5 13 401.88 23 14.14 904 294 3.61 / 294.21 1 2
6 14 0.04 190 14.38 295 806 4.42 / 295.02 2 9
Average= 4.47 (KJ/cycle)

Cycle 64 GMT 19/ 6/2016 15: 9: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 26 14.63 448 170 0.17 / 286.12 2 2
2 7 2003.68 51 11.92 3236 1967 2.14 / 288.09 1 2
3 13 1608.76 23 13.18 2579 782 2.92 / 288.87 1 2
4 13 999.80 23 13.64 1704 535 3.45 / 289.41 1 2
5 13 360.24 23 14.17 857 279 3.73 / 289.69 1 2
6 13 0.84 23 14.54 308 103 3.84 / 289.79 1 2
7 14 0.00 190 14.31 296 805 4.64 / 290.60 2 15
Average= 4.47 (KJ/cycle)

Cycle 63 GMT 9/ 6/2016 14:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 27 14.65 431 170 0.17 / 281.55 2 2
2 3 970.68 -1 14.65 431 0 0.00 / 281.55 2 2
3 3 1033.80 1 13.51 1884 25 0.20 / 281.57 1 1
4 7 2005.44 50 11.96 3223 1927 2.12 / 283.50 1 2
5 13 1605.16 22 13.20 2577 748 2.87 / 284.25 1 2
6 13 1179.20 22 13.53 1926 573 3.44 / 284.82 1 2
7 13 520.36 22 14.02 1066 329 3.77 / 285.15 1 3
8 14 -0.04 190 14.36 295 805 4.58 / 285.95 2 5
Average= 4.47 (KJ/cycle)

Cycle 62 GMT 30/ 5/2016 14:37:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 27 14.67 445 176 0.18 / 277.12 2 2
2 7 2004.76 50 12.04 3247 1955 2.13 / 279.07 2 2
3 13 1604.92 22 13.21 2585 751 2.88 / 279.82 1 2
4 13 963.68 22 13.68 1636 492 3.37 / 280.32 1 5
5 13 340.44 22 14.18 828 258 3.63 / 280.57 1 2
6 14 0.00 190 14.39 293 801 4.43 / 281.38 2 7
Average= 4.47 (KJ/cycle)

Cycle 61 GMT 20/ 5/2016 14: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 27 14.69 428 170 0.17 / 272.59 2 2
2 7 2002.60 50 12.09 3242 1960 2.13 / 274.55 2 2
3 13 1447.40 22 13.32 2366 693 2.82 / 275.24 1 3
4 13 890.28 22 13.75 1549 469 3.29 / 275.71 1 2
5 13 468.72 23 14.08 1009 327 3.62 / 276.04 1 2
6 13 5.60 23 14.56 309 103 3.72 / 276.14 1 2
7 14 -0.24 190 14.33 294 800 4.52 / 276.94 2 11
Average= 4.47 (KJ/cycle)

Cycle 60 GMT 10/ 5/2016 13:22: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 26 14.67 452 172 0.17 / 268.07 1 2
2 3 1037.40 1 13.76 1890 26 0.20 / 268.10 1 1
3 7 2008.12 50 12.20 3242 1978 2.18 / 270.08 1 2
4 13 1614.24 22 13.24 2610 760 2.94 / 270.84 1 3
5 13 994.80 22 13.69 1676 505 3.44 / 271.34 1 2
6 13 359.44 23 14.19 853 278 3.72 / 271.62 1 2
7 14 0.00 190 14.40 292 799 4.52 / 272.42 1 7
Average= 4.47 (KJ/cycle)

Cycle 59 GMT 30/ 4/2016 12:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 25 14.71 433 159 0.16 / 263.60 2 2
2 7 2002.44 50 12.30 3236 1990 2.15 / 265.59 1 2
3 13 1601.00 22 13.27 2573 751 2.90 / 266.34 1 2
4 13 970.24 22 13.69 1669 503 3.40 / 266.84 1 2
5 13 333.32 22 14.20 817 255 3.66 / 267.10 1 2
6 14 -0.08 190 14.38 295 806 4.46 / 267.90 2 9
Average= 4.47 (KJ/cycle)

Cycle 58 GMT 20/ 4/2016 12:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 26 14.69 430 164 0.16 / 259.06 2 2
2 3 950.92 -1 14.69 430 0 0.00 / 259.06 2 2
3 3 1019.48 1 12.83 1909 24 0.19 / 259.08 1 1
4 7 2001.84 51 12.36 3233 2038 2.23 / 261.12 1 2
5 13 1407.52 23 13.36 2323 714 2.94 / 261.83 1 2
6 13 1003.36 23 13.67 1714 539 3.48 / 262.37 1 2
7 13 329.16 23 14.18 817 266 3.75 / 262.64 1 2
8 14 -0.12 190 14.40 292 799 4.54 / 263.44 2 9
Average= 4.47 (KJ/cycle)

Cycle 57 GMT 10/ 4/2016 12:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 26 14.72 440 168 0.17 / 254.52 2 2
2 7 2009.60 51 12.45 3240 2057 2.23 / 256.58 1 2
3 13 1603.20 23 13.25 2622 799 3.02 / 257.38 1 2
4 13 790.52 23 13.81 1422 452 3.48 / 257.83 1 2
5 13 368.84 22 14.17 841 262 3.74 / 258.09 1 2
6 14 -0.04 190 14.37 293 800 4.54 / 258.89 2 13
Average= 4.46 (KJ/cycle)

Cycle 56 GMT 31/ 3/2016 12: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 27 14.67 432 171 0.17 / 250.21 2 2
2 3 967.16 -1 14.67 432 0 0.00 / 250.21 2 2
3 3 1032.68 1 13.59 1896 26 0.20 / 250.23 1 2
4 7 2005.16 50 12.45 3212 1999 2.20 / 252.23 2 2
5 13 1423.08 22 13.38 2337 688 2.88 / 252.92 1 4
6 13 810.16 22 13.81 1443 438 3.32 / 253.36 1 2
7 13 198.60 22 14.35 616 194 3.52 / 253.55 1 2
8 14 -0.12 190 14.40 293 802 4.32 / 254.35 2 9
Average= 4.46 (KJ/cycle)

Cycle 55 GMT 21/ 3/2016 11:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 27 14.71 449 178 0.18 / 245.73 2 2
2 7 2002.88 50 12.53 3223 2019 2.20 / 247.75 2 2
3 13 1591.52 22 13.29 2578 754 2.95 / 248.50 1 2
4 13 949.36 22 13.72 1641 495 3.45 / 249.00 1 3
5 13 289.96 22 14.25 745 234 3.68 / 249.23 1 2
6 14 -0.12 190 14.40 293 802 4.48 / 250.03 1 10
Average= 4.46 (KJ/cycle)

Cycle 54 GMT 11/ 3/2016 11: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 26 14.69 445 170 0.17 / 241.11 2 2
2 7 2026.44 50 12.49 3266 2040 2.21 / 243.15 1 2
3 13 1849.84 22 13.12 2962 855 3.06 / 244.01 1 1
4 13 953.52 22 13.71 1636 493 3.56 / 244.50 1 3
5 13 313.32 22 14.24 794 249 3.81 / 244.75 1 2
6 14 -0.16 190 14.41 293 802 4.61 / 245.55 2 7
Average= 4.46 (KJ/cycle)

Cycle 53 GMT 1/ 3/2016 10:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 26 14.71 434 166 0.17 / 236.47 2 2
2 7 2001.80 30 12.78 3236 1241 1.41 / 237.71 1 1
3 13 1835.24 20 13.17 2926 771 2.18 / 238.48 1 2
4 13 1632.96 20 13.34 2627 701 2.88 / 239.18 1 2
5 13 1192.52 20 13.59 2022 550 3.43 / 239.73 1 2
6 13 509.28 20 14.08 1065 300 3.73 / 240.03 1 2
7 13 54.52 20 14.50 392 114 3.84 / 240.14 1 2
8 14 -0.12 190 14.36 294 802 4.64 / 240.94 1 10
Average= 4.46 (KJ/cycle)

Cycle 52 GMT 20/ 2/2016 10:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 26 14.69 432 165 0.16 / 231.84 2 2
2 7 2004.96 30 12.73 3259 1245 1.41 / 233.08 2 2
3 13 1836.52 21 13.15 2959 817 2.23 / 233.90 1 2
4 13 1629.12 21 13.33 2610 731 2.96 / 234.63 1 4
5 13 964.28 20 13.74 1657 455 3.41 / 235.08 1 2
6 13 534.40 20 14.08 1091 307 3.72 / 235.39 1 2
7 13 28.80 20 14.55 349 102 3.82 / 235.49 1 2
8 14 -0.12 190 14.33 297 809 4.63 / 236.30 1 11
Average= 4.46 (KJ/cycle)

Cycle 51 GMT 10/ 2/2016 10: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 26 14.70 444 170 0.17 / 227.27 2 2
2 7 2003.84 30 12.78 3234 1240 1.41 / 228.51 1 2
3 13 1837.08 20 13.14 2945 774 2.18 / 229.29 1 2
4 13 1636.68 20 13.32 2625 699 2.88 / 229.99 1 2
5 13 975.48 20 13.74 1693 465 3.35 / 230.45 1 2
6 13 526.40 20 14.09 1090 307 3.66 / 230.76 1 2
7 13 30.00 20 14.55 353 103 3.76 / 230.86 1 2
8 14 0.00 190 14.34 297 809 4.57 / 231.67 2 10
Average= 4.46 (KJ/cycle)

Cycle 50 GMT 31/ 1/2016 9:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 26 14.70 449 172 0.17 / 222.52 2 2
2 7 2002.00 30 12.62 3268 1237 1.41 / 223.76 1 2
3 13 1847.72 20 13.10 2958 775 2.18 / 224.53 1 2
4 13 1654.52 20 13.28 2644 702 2.89 / 225.24 1 2
5 13 1210.48 21 13.58 2019 576 3.46 / 225.81 1 2
6 13 527.44 20 14.07 1080 304 3.77 / 226.11 1 2
7 13 31.12 20 14.55 352 102 3.87 / 226.22 1 2
8 13 3.24 20 14.52 304 88 3.96 / 226.31 1 2
9 14 -0.16 190 14.33 293 798 4.75 / 227.10 2 13
Average= 4.45 (KJ/cycle)

Cycle 49 GMT 21/ 1/2016 9:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 27 14.66 444 176 0.18 / 217.92 2 2
2 3 952.56 -1 14.66 444 0 0.00 / 217.92 2 2
3 7 2001.00 30 12.63 3237 1226 1.40 / 219.14 1 1
4 13 1847.60 20 13.12 2969 779 2.18 / 219.92 1 2
5 13 1654.80 20 13.30 2651 705 2.89 / 220.63 1 2
6 13 1191.00 20 13.61 1956 532 3.42 / 221.16 1 2
7 13 515.96 20 14.10 1028 290 3.71 / 221.45 1 1
8 13 13.96 20 14.58 320 93 3.80 / 221.54 2 2
9 14 -0.08 190 14.35 296 807 4.61 / 222.35 2 9
Average= 4.45 (KJ/cycle)

Cycle 48 GMT 11/ 1/2016 9: 7: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 27 14.70 443 176 0.18 / 213.28 2 2
2 7 2004.20 31 12.77 3252 1287 1.46 / 214.56 2 1
3 13 1851.88 21 13.16 2984 825 2.29 / 215.39 1 1
4 13 1445.36 21 13.45 2362 667 2.96 / 216.06 1 1
5 13 1027.92 20 13.75 1713 471 3.43 / 216.53 1 1
6 13 577.92 20 14.08 1093 308 3.73 / 216.84 1 2
7 13 13.64 20 14.58 324 94 3.83 / 216.93 1 1
8 14 -0.12 190 14.35 297 810 4.64 / 217.74 2 10
Average= 4.44 (KJ/cycle)

Cycle 47 GMT 1/ 1/2016 8:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 25 14.74 438 161 0.16 / 208.65 2 2
2 3 1036.00 1 13.96 1920 27 0.19 / 208.68 1 1
3 3 1022.48 1 13.76 1874 26 0.21 / 208.70 1 1
4 7 2002.20 30 12.71 3240 1235 1.45 / 209.94 1 2
5 13 1840.80 20 13.18 2927 772 2.22 / 210.71 1 1
6 13 1636.68 20 13.35 2616 698 2.92 / 211.41 1 1
7 13 985.24 20 13.77 1681 463 3.38 / 211.87 1 1
8 13 552.72 20 14.11 1104 312 3.69 / 212.18 1 2
9 13 31.88 20 14.56 360 105 3.80 / 212.29 1 2
10 14 -0.12 190 14.35 298 812 4.61 / 213.10 2 12
Average= 4.44 (KJ/cycle)

Cycle 46 GMT 22/12/2015 8: 6: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 25 14.73 435 160 0.16 / 204.03 2 2
2 7 2006.00 30 12.75 3223 1233 1.39 / 205.26 1 2
3 13 1851.28 20 13.15 2963 779 2.17 / 206.04 1 1
4 13 1636.08 20 13.35 2641 705 2.88 / 206.74 1 1
5 13 1170.56 20 13.65 1969 538 3.41 / 207.28 1 2
6 13 488.32 21 14.16 1021 304 3.72 / 207.59 1 1
7 13 28.96 20 14.59 350 102 3.82 / 207.69 1 2
8 14 -0.08 190 14.37 294 803 4.62 / 208.49 2 11
Average= 4.44 (KJ/cycle)

Cycle 45 GMT 12/12/2015 7:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 25 14.72 434 160 0.16 / 199.45 2 2
2 7 2007.72 30 12.73 3259 1245 1.40 / 200.70 1 1
3 13 1852.00 20 13.16 2980 784 2.19 / 201.48 1 2
4 13 1633.68 20 13.35 2629 702 2.89 / 202.18 1 2
5 13 996.08 20 13.78 1691 466 3.36 / 202.65 1 2
6 13 541.88 20 14.12 1098 310 3.67 / 202.96 1 2
7 13 14.76 20 14.60 329 96 3.76 / 203.05 1 2
8 14 -0.16 190 14.36 298 813 4.58 / 203.87 1 9
Average= 4.43 (KJ/cycle)

Cycle 44 GMT 2/12/2015 7:38:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 26 14.72 441 169 0.17 / 194.91 2 2
2 3 965.32 -1 14.72 441 0 0.00 / 194.91 2 2
3 3 1021.00 1 13.71 1897 26 0.19 / 194.94 1 1
4 7 2003.04 30 12.76 3235 1238 1.43 / 196.18 1 2
5 13 1846.44 20 13.18 2940 775 2.21 / 196.95 1 2
6 13 1632.32 20 13.35 2617 699 2.91 / 197.65 1 2
7 13 1179.12 20 13.66 1966 537 3.44 / 198.19 1 1
8 13 487.20 20 14.16 1016 288 3.73 / 198.48 1 1
9 14 -0.16 190 14.40 298 815 4.55 / 199.29 1 7
Average= 4.43 (KJ/cycle)

Cycle 43 GMT 22/11/2015 7:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 25 14.71 453 167 0.17 / 190.47 2 2
2 7 2001.84 30 12.84 3219 1240 1.41 / 191.71 1 1
3 13 1835.52 20 13.22 2928 774 2.18 / 192.49 1 1
4 13 1626.24 20 13.37 2629 703 2.88 / 193.19 1 1
5 13 961.68 20 13.81 1661 459 3.34 / 193.65 1 2
6 13 511.56 20 14.16 1012 287 3.63 / 193.94 1 2
7 14 -0.12 190 14.41 295 808 4.44 / 194.74 1 7
Average= 4.43 (KJ/cycle)

Cycle 42 GMT 12/11/2015 7: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 26 14.67 452 172 0.17 / 185.77 2 2
2 3 961.36 -1 14.67 452 0 0.00 / 185.77 2 2
3 3 1029.68 1 14.04 1910 27 0.20 / 185.79 1 1
4 7 2001.72 30 12.90 3203 1240 1.44 / 187.03 1 1
5 13 1852.12 20 13.24 2947 780 2.22 / 187.81 1 1
6 13 1650.64 20 13.40 2603 698 2.92 / 188.51 1 2
7 13 1180.84 20 13.71 1954 536 3.45 / 189.05 1 2
8 13 494.28 20 14.17 1031 292 3.74 / 189.34 1 1
9 13 119.64 20 14.52 498 145 3.89 / 189.48 1 2
10 14 -0.04 190 14.38 301 822 4.71 / 190.31 1 12
Average= 4.43 (KJ/cycle)

Cycle 41 GMT 2/11/2015 7:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 26 14.69 458 175 0.17 / 181.22 2 2
2 7 2001.28 30 13.03 3200 1251 1.43 / 182.47 2 2
3 13 1824.20 20 13.29 2946 783 2.21 / 183.26 1 2
4 13 1615.28 20 13.44 2596 698 2.91 / 183.95 1 1
5 13 1161.24 20 13.74 1922 528 3.43 / 184.48 1 2
6 13 467.72 20 14.20 1002 285 3.72 / 184.77 1 1
7 14 -0.08 190 14.41 303 830 4.55 / 185.60 2 8
Average= 4.42 (KJ/cycle)

Cycle 40 GMT 23/10/2015 7:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 26 14.68 463 177 0.18 / 176.68 2 2
2 7 2005.96 30 13.05 3209 1256 1.43 / 177.94 2 2
3 13 1835.96 20 13.29 2921 776 2.21 / 178.72 1 1
4 13 1618.16 20 13.47 2573 693 2.90 / 179.41 1 1
5 13 1150.96 20 13.76 1910 526 3.43 / 179.93 1 2
6 13 462.32 20 14.23 987 281 3.71 / 180.21 1 2
7 14 0.00 191 14.42 302 832 4.54 / 181.05 2 8
Average= 4.42 (KJ/cycle)

Cycle 39 GMT 13/10/2015 7:22: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 26 14.71 457 175 0.17 / 172.17 2 2
2 7 2002.00 30 12.99 3199 1247 1.42 / 173.42 1 2
3 13 1848.76 20 13.27 2928 777 2.20 / 174.20 1 2
4 13 1643.56 20 13.45 2599 699 2.90 / 174.90 1 1
5 13 975.16 21 13.86 1663 484 3.38 / 175.38 1 1
6 13 538.32 20 14.19 1048 297 3.68 / 175.68 1 1
7 14 -0.08 190 14.41 302 827 4.51 / 176.51 1 11
Average= 4.41 (KJ/cycle)

Cycle 38 GMT 3/10/2015 7:10:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 26 14.71 452 173 0.17 / 167.78 2 2
2 3 972.32 -1 14.71 452 0 0.00 / 167.78 2 2
3 3 1034.36 1 14.17 1892 27 0.20 / 167.80 1 1
4 7 2000.84 30 13.03 3191 1247 1.45 / 169.05 1 2
5 13 1848.20 20 13.29 2945 783 2.23 / 169.83 1 1
6 13 1432.28 20 13.57 2338 635 2.86 / 170.47 1 1
7 13 1004.76 20 13.86 1678 465 3.33 / 170.93 1 1
8 13 352.16 20 14.34 845 242 3.57 / 171.18 1 2
9 14 0.12 190 14.42 301 825 4.40 / 172.00 2 8
Average= 4.41 (KJ/cycle)

Cycle 37 GMT 23/ 9/2015 7: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 26 14.69 463 177 0.18 / 163.23 2 2
2 7 2004.80 31 13.04 3204 1295 1.47 / 164.52 2 1
3 13 1845.76 20 13.29 2926 778 2.25 / 165.30 1 1
4 13 1634.76 20 13.42 2681 720 2.97 / 166.02 1 1
5 13 958.80 20 13.89 1633 454 3.42 / 166.48 1 1
6 13 514.88 20 14.21 1065 303 3.73 / 166.78 1 2
7 14 -0.28 190 14.42 301 825 4.55 / 167.60 1 12
Average= 4.41 (KJ/cycle)

Cycle 36 GMT 13/ 9/2015 6:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 26 14.71 439 168 0.17 / 158.71 2 2
2 7 2008.36 30 13.09 3211 1261 1.43 / 159.97 2 1
3 13 1827.16 20 13.33 2887 770 2.20 / 160.74 1 1
4 13 1608.56 20 13.48 2583 696 2.89 / 161.43 1 1
5 13 962.56 20 13.88 1696 471 3.37 / 161.91 1 1
6 13 517.36 20 14.23 1070 305 3.67 / 162.21 1 2
7 14 0.16 191 14.42 306 843 4.51 / 163.05 2 9
Average= 4.41 (KJ/cycle)

Cycle 35 GMT 3/ 9/2015 6:56: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 26 14.70 465 178 0.18 / 154.18 2 2
2 7 2007.28 30 13.10 3208 1261 1.44 / 155.44 2 2
3 13 1833.24 20 13.29 2948 784 2.22 / 156.22 1 1
4 13 1623.56 20 13.47 2609 703 2.92 / 156.93 1 1
5 13 971.88 20 13.89 1672 464 3.39 / 157.39 1 2
6 13 315.60 20 14.39 794 229 3.62 / 157.62 1 2
7 13 15.64 20 14.68 331 97 3.72 / 157.72 1 2
8 14 -0.20 190 14.39 301 823 4.54 / 158.54 2 15
Average= 4.40 (KJ/cycle)

Cycle 34 GMT 24/ 8/2015 6:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 26 14.71 456 174 0.17 / 149.74 2 2
2 7 2002.20 30 13.10 3193 1255 1.43 / 151.00 2 2
3 13 1838.52 20 13.30 2920 777 2.21 / 151.77 1 1
4 13 1626.48 20 13.49 2583 697 2.90 / 152.47 1 2
5 13 975.20 20 13.89 1674 465 3.37 / 152.94 1 1
6 13 320.68 20 14.40 804 232 3.60 / 153.17 1 2
7 14 0.04 190 14.41 305 835 4.43 / 154.00 1 10
Average= 4.40 (KJ/cycle)

Cycle 33 GMT 14/ 8/2015 6:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 26 14.68 468 179 0.18 / 145.30 1 2
2 7 2007.72 30 13.11 3210 1262 1.44 / 146.56 2 2
3 13 1834.00 20 13.32 2937 782 2.22 / 147.34 1 1
4 13 1621.48 20 13.47 2601 701 2.92 / 148.04 1 1
5 13 961.24 21 13.92 1653 483 3.41 / 148.53 1 2
6 13 295.96 20 14.42 765 221 3.63 / 148.75 1 2
7 14 0.04 190 14.44 299 820 4.45 / 149.57 1 10
Average= 4.40 (KJ/cycle)

Cycle 32 GMT 4/ 8/2015 6:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 26 14.71 464 177 0.18 / 140.83 1 2
2 7 2003.92 30 13.11 3204 1260 1.44 / 142.09 2 2
3 13 1836.60 21 13.29 2930 818 2.26 / 142.91 1 2
4 13 1621.24 20 13.49 2584 697 2.95 / 143.61 1 2
5 13 951.24 20 13.91 1658 461 3.41 / 144.07 1 1
6 13 305.24 20 14.43 778 225 3.64 / 144.29 1 2
7 14 -0.08 190 14.43 301 825 4.46 / 145.12 1 11
Average= 4.40 (KJ/cycle)

Cycle 31 GMT 25/ 7/2015 6:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 26 14.70 459 175 0.18 / 136.17 2 2
2 7 2003.44 30 13.11 3198 1258 1.43 / 137.43 1 1
3 13 1837.36 20 13.31 2934 781 2.21 / 138.21 1 1
4 13 1621.64 20 13.45 2624 706 2.92 / 138.92 1 1
5 13 1167.80 20 13.80 1900 524 3.44 / 139.44 1 1
6 13 484.36 20 14.27 1022 292 3.74 / 139.74 1 1
7 13 25.36 20 14.68 346 102 3.84 / 139.84 1 2
8 14 0.08 190 14.40 299 818 4.66 / 140.66 2 13
Average= 4.40 (KJ/cycle)

Cycle 30 GMT 15/ 7/2015 6:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 26 14.71 447 171 0.17 / 131.70 2 2
2 7 2001.40 30 13.11 3185 1253 1.42 / 132.95 2 2
3 13 1827.28 20 13.29 2938 781 2.20 / 133.74 1 2
4 13 1613.60 20 13.47 2583 696 2.90 / 134.43 1 2
5 13 944.08 20 13.93 1604 447 3.35 / 134.88 1 2
6 13 489.36 20 14.26 1048 299 3.65 / 135.18 1 2
7 14 -0.04 190 14.43 300 823 4.47 / 136.00 2 11
Average= 4.39 (KJ/cycle)

Cycle 29 GMT 5/ 7/2015 6:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 26 14.73 456 175 0.17 / 127.17 2 2
2 7 2001.64 30 13.12 3221 1268 1.44 / 128.43 1 1
3 13 1825.96 20 13.29 2944 783 2.22 / 129.22 1 1
4 13 1619.16 20 13.47 2598 700 2.92 / 129.92 1 1
5 13 952.44 21 13.94 1610 471 3.40 / 130.39 1 1
6 13 512.88 21 14.25 1070 320 3.72 / 130.71 1 2
7 14 -0.08 190 14.43 300 823 4.54 / 131.53 1 10
Average= 4.38 (KJ/cycle)

Cycle 28 GMT 25/ 6/2015 6: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 26 14.70 452 173 0.17 / 122.65 1 2
2 7 2004.76 30 13.14 3206 1264 1.44 / 123.91 2 1
3 13 1842.40 20 13.29 2958 786 2.22 / 124.70 1 1
4 13 1623.32 20 13.47 2617 705 2.93 / 125.40 1 1
5 13 959.40 20 13.91 1669 464 3.39 / 125.87 1 2
6 13 505.68 20 14.27 1041 297 3.69 / 126.16 1 1
7 14 0.12 190 14.43 302 828 4.52 / 126.99 2 9
Average= 4.38 (KJ/cycle)

Cycle 27 GMT 15/ 6/2015 6: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 26 14.71 449 172 0.17 / 118.11 1 2
2 7 2001.68 31 13.14 3192 1300 1.47 / 119.41 1 1
3 13 1820.60 20 13.33 2897 772 2.24 / 120.19 1 2
4 13 1614.56 21 13.51 2544 722 2.97 / 120.91 1 1
5 13 945.52 20 13.94 1631 455 3.42 / 121.36 1 1
6 13 486.08 20 14.28 1015 290 3.71 / 121.65 1 2
7 14 -0.16 190 14.44 300 823 4.53 / 122.47 2 16
Average= 4.37 (KJ/cycle)

Cycle 26 GMT 5/ 6/2015 6: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 26 14.75 440 169 0.17 / 113.72 2 2
2 7 2002.88 30 13.18 3207 1268 1.44 / 114.99 2 1
3 13 1848.92 20 13.31 2954 786 2.22 / 115.78 1 2
4 13 1442.96 20 13.61 2332 635 2.86 / 116.41 1 2
5 13 999.52 20 13.91 1693 471 3.33 / 116.88 1 2
6 13 327.60 20 14.41 811 234 3.56 / 117.12 1 1
7 14 -0.16 190 14.43 300 823 4.39 / 117.94 2 11
Average= 4.37 (KJ/cycle)

Cycle 25 GMT 26/ 5/2015 5:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 26 14.77 442 170 0.17 / 109.12 1 2
2 7 2002.00 30 13.20 3186 1262 1.43 / 110.38 1 2
3 13 1833.76 20 13.33 2933 782 2.21 / 111.16 1 1
4 13 1623.36 20 13.50 2606 704 2.92 / 111.87 1 2
5 13 944.84 20 13.95 1618 451 3.37 / 112.32 1 1
6 13 490.48 20 14.27 1054 301 3.67 / 112.62 1 2
7 13 50.80 20 14.68 390 115 3.78 / 112.73 1 2
8 14 0.00 190 14.41 301 824 4.61 / 113.56 2 12
Average= 4.37 (KJ/cycle)

Cycle 24 GMT 16/ 5/2015 5:59: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 26 14.76 433 166 0.17 / 104.43 2 2
2 3 967.60 -1 14.76 433 0 0.00 / 104.43 2 2
3 3 1025.40 1 14.49 1908 28 0.19 / 104.45 1 1
4 7 2003.16 30 13.20 3199 1267 1.46 / 105.72 1 2
5 13 1833.80 20 13.33 2903 774 2.23 / 106.49 1 1
6 13 1639.40 20 13.49 2606 703 2.94 / 107.20 1 2
7 13 1173.08 20 13.80 1978 546 3.48 / 107.74 1 2
8 13 461.08 20 14.32 981 281 3.76 / 108.02 1 2
9 13 48.68 20 14.70 382 112 3.88 / 108.14 1 2
10 14 -0.20 190 14.43 296 812 4.69 / 108.95 1 14
Average= 4.36 (KJ/cycle)

Cycle 23 GMT 6/ 5/2015 6:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 26 14.76 438 168 0.17 / 100.02 1 2
2 7 2001.12 31 13.22 3187 1306 1.47 / 101.32 2 2
3 13 1825.96 20 13.35 2905 776 2.25 / 102.10 1 2
4 13 1409.32 21 13.65 2306 661 2.91 / 102.76 1 2
5 13 980.96 20 13.93 1667 464 3.38 / 103.23 1 2
6 13 313.16 20 14.45 779 225 3.60 / 103.45 1 2
7 14 0.04 190 14.48 294 809 4.41 / 104.26 2 8
Average= 4.34 (KJ/cycle)

Cycle 22 GMT 26/ 4/2015 7:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 26 14.76 444 170 0.17 / 95.62 2 2
2 7 2003.48 30 13.29 3188 1271 1.44 / 96.89 2 1
3 13 1833.00 20 13.36 2906 776 2.22 / 97.67 1 2
4 13 1616.48 20 13.51 2626 710 2.93 / 98.38 1 1
5 13 952.64 20 13.96 1624 453 3.38 / 98.83 1 1
6 13 286.28 20 14.48 748 217 3.60 / 99.05 1 2
7 14 -0.16 190 14.47 291 800 4.40 / 99.85 1 9
Average= 4.34 (KJ/cycle)

Cycle 21 GMT 16/ 4/2015 7:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 26 14.79 449 173 0.17 / 91.04 2 2
2 7 2001.92 30 13.32 3183 1272 1.44 / 92.31 2 1
3 13 1834.36 20 13.35 2939 785 2.23 / 93.10 1 1
4 13 1621.40 20 13.53 2586 700 2.93 / 93.80 1 2
5 13 958.68 20 13.96 1646 460 3.39 / 94.26 1 2
6 13 505.72 20 14.30 1021 292 3.68 / 94.55 1 2
7 13 11.28 21 14.79 319 99 3.78 / 94.65 1 2
8 14 0.00 190 14.44 293 804 4.58 / 95.45 2 12
Average= 4.34 (KJ/cycle)

Cycle 20 GMT 6/ 4/2015 8:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 26 14.80 439 169 0.17 / 86.67 2 2
2 7 2007.60 30 13.34 3182 1273 1.44 / 87.94 2 1
3 13 1845.48 20 13.40 2900 777 2.22 / 88.72 1 1
4 13 1437.00 20 13.65 2349 641 2.86 / 89.36 1 2
5 13 988.04 20 13.94 1685 470 3.33 / 89.83 1 2
6 13 323.12 20 14.45 806 233 3.56 / 90.06 1 2
7 14 -0.20 190 14.49 293 807 4.37 / 90.87 1 11
Average= 4.33 (KJ/cycle)

Cycle 19 GMT 27/ 3/2015 8:44: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 26 14.80 441 170 0.17 / 82.00 2 2
2 7 2003.88 30 13.36 3182 1275 1.45 / 83.27 2 2
3 13 1832.28 20 13.39 2919 782 2.23 / 84.05 1 1
4 13 1630.28 20 13.53 2617 708 2.93 / 84.76 1 2
5 13 1147.20 20 13.85 1915 530 3.47 / 85.29 1 2
6 13 439.96 20 14.36 948 272 3.74 / 85.56 1 2
7 13 86.00 20 14.69 442 130 3.87 / 85.69 1 2
8 14 0.04 190 14.48 293 806 4.67 / 86.50 2 14
Average= 4.32 (KJ/cycle)

Cycle 18 GMT 17/ 3/2015 9:30: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 26 14.82 432 166 0.17 / 77.44 2 2
2 7 2006.56 30 13.37 3197 1282 1.45 / 78.72 2 1
3 13 1852.16 20 13.40 2924 784 2.23 / 79.51 1 2
4 13 1634.80 20 13.54 2621 710 2.94 / 80.22 1 1
5 13 969.76 21 13.97 1665 488 3.43 / 80.71 1 2
6 13 307.08 20 14.47 775 224 3.65 / 80.93 1 2
7 13 11.24 20 14.81 316 94 3.75 / 81.02 1 2
8 14 -0.20 190 14.45 292 802 4.55 / 81.83 2 20
Average= 4.31 (KJ/cycle)

Cycle 17 GMT 7/ 3/2015 9:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 26 14.84 438 169 0.17 / 72.92 2 2
2 7 2001.08 30 13.42 3167 1275 1.44 / 74.20 1 2
3 13 1831.56 20 13.40 2948 790 2.23 / 74.99 1 2
4 13 1613.04 20 13.57 2569 697 2.93 / 75.68 1 2
5 13 947.56 21 14.00 1603 471 3.40 / 76.15 1 2
6 13 304.68 20 14.49 773 224 3.63 / 76.38 1 2
7 13 25.68 20 14.81 337 100 3.73 / 76.48 2 2
8 14 0.16 190 14.48 290 798 4.52 / 77.28 1 13
Average= 4.29 (KJ/cycle)

Cycle 16 GMT 25/ 2/2015 10:21: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 26 14.86 431 167 0.17 / 68.20 2 2
2 7 2001.76 30 13.41 3166 1274 1.44 / 69.47 2 1
3 13 1832.92 20 13.41 2937 788 2.23 / 70.26 1 2
4 13 1621.96 20 13.58 2532 688 2.92 / 70.95 1 1
5 13 1147.32 20 13.87 1876 520 3.44 / 71.47 1 2
6 13 674.40 20 14.17 1294 367 3.80 / 71.84 1 2
7 13 68.00 20 14.77 405 120 3.92 / 71.96 1 2
8 14 -0.20 190 14.52 288 795 4.72 / 72.75 2 10
Average= 4.28 (KJ/cycle)

Cycle 15 GMT 15/ 2/2015 11:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 26 14.85 439 169 0.17 / 63.78 2 2
2 7 2002.76 30 13.42 3196 1287 1.46 / 65.06 2 2
3 13 1833.68 20 13.40 2960 793 2.25 / 65.86 1 1
4 13 1616.28 20 13.57 2606 707 2.96 / 66.57 1 1
5 13 937.44 20 13.98 1634 457 3.41 / 67.02 1 2
6 13 273.52 20 14.53 725 211 3.62 / 67.23 1 2
7 14 -0.04 190 14.54 290 801 4.43 / 68.03 2 9
Average= 4.25 (KJ/cycle)

Cycle 14 GMT 5/ 2/2015 11:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 27 14.84 427 171 0.17 / 59.17 2 2
2 3 973.00 -1 14.84 427 0 0.00 / 59.17 2 2
3 3 1034.08 1 14.63 1912 28 0.20 / 59.19 1 1
4 7 2003.20 30 13.45 3158 1274 1.47 / 60.47 1 2
5 13 1835.76 20 13.42 2881 773 2.25 / 61.24 1 2
6 13 1617.00 20 13.57 2566 696 2.94 / 61.94 1 2
7 13 948.80 21 13.97 1621 476 3.42 / 62.41 1 2
8 13 496.88 20 14.31 1063 304 3.72 / 62.72 1 2
9 13 10.12 20 14.86 312 93 3.82 / 62.81 1 2
10 14 -0.04 190 14.49 290 798 4.61 / 63.61 2 9
Average= 4.24 (KJ/cycle)

Cycle 13 GMT 26/ 1/2015 12:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 26 14.84 432 167 0.17 / 54.70 2 2
2 3 1025.16 1 14.66 1879 28 0.19 / 54.73 1 1
3 7 2005.96 30 13.44 3185 1284 1.48 / 56.01 1 2
4 13 1838.92 20 13.41 2933 787 2.27 / 56.80 1 2
5 13 1628.12 20 13.53 2639 714 2.98 / 57.51 1 2
6 13 962.12 20 13.96 1656 462 3.44 / 57.98 1 2
7 13 296.12 20 14.53 756 220 3.66 / 58.20 1 2
8 14 -0.16 190 14.54 289 798 4.46 / 58.99 2 9
Average= 4.21 (KJ/cycle)

Cycle 12 GMT 16/ 1/2015 13: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 25 14.87 440 164 0.16 / 50.09 2 2
2 7 2008.04 30 13.44 3195 1288 1.45 / 51.38 1 1
3 13 1834.60 20 13.43 2895 778 2.23 / 52.16 1 2
4 13 1616.48 20 13.57 2592 703 2.93 / 52.86 1 1
5 13 936.28 20 13.96 1643 459 3.39 / 53.32 1 2
6 13 491.72 20 14.34 1036 297 3.69 / 53.62 1 2
7 13 45.68 20 14.81 372 110 3.80 / 53.73 2 2
8 14 -0.08 191 14.48 292 808 4.61 / 54.54 2 20
Average= 4.20 (KJ/cycle)

Cycle 11 GMT 6/ 1/2015 13:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 24 14.84 443 158 0.16 / 45.54 2 2
2 3 1024.04 1 14.66 1887 28 0.19 / 45.56 1 2
3 7 2005.32 30 13.47 3191 1289 1.47 / 46.85 1 2
4 13 1832.44 20 13.40 2939 788 2.26 / 47.64 1 2
5 13 1417.60 20 13.64 2311 630 2.89 / 48.27 1 1
6 13 970.44 20 13.95 1651 461 3.35 / 48.73 1 2
7 13 508.04 20 14.32 1031 295 3.65 / 49.03 1 2
8 13 8.08 20 14.85 313 93 3.74 / 49.12 1 2
9 14 -0.08 190 14.47 294 808 4.55 / 49.93 2 18
Average= 4.16 (KJ/cycle)

Cycle 10 GMT 27/12/2014 14:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 26 14.85 442 171 0.17 / 41.07 2 2
2 3 971.64 -1 14.85 442 0 0.00 / 41.07 2 2
3 7 2002.84 30 13.49 3157 1278 1.45 / 42.34 2 2
4 13 1829.12 20 13.44 2862 769 2.22 / 43.11 1 2
5 13 1393.88 20 13.66 2263 618 2.84 / 43.73 1 2
6 13 954.32 20 13.97 1593 445 3.28 / 44.18 1 2
7 13 483.84 20 14.34 972 279 3.56 / 44.45 1 1
8 13 44.24 20 14.79 376 111 3.67 / 44.57 1 2
9 14 -0.04 190 14.45 296 813 4.48 / 45.38 2 10
Average= 4.13 (KJ/cycle)

Cycle 9 GMT 17/12/2014 15: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 26 14.82 439 169 0.17 / 36.72 2 2
2 7 2006.40 30 13.49 3204 1297 1.47 / 38.02 2 2
3 13 1840.16 20 13.42 2929 786 2.25 / 38.80 1 1
4 13 1401.68 20 13.65 2289 625 2.88 / 39.43 1 2
5 13 945.88 20 13.97 1603 448 3.32 / 39.87 1 2
6 13 262.16 20 14.58 711 207 3.53 / 40.08 1 2
7 14 0.04 190 14.51 295 813 4.35 / 40.89 1 11
Average= 4.09 (KJ/cycle)

Cycle 8 GMT 7/12/2014 15:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 26 14.82 443 171 0.17 / 32.12 2 2
2 7 2002.68 30 13.51 3165 1283 1.45 / 33.41 2 1
3 13 1831.32 20 13.44 2864 770 2.22 / 34.18 1 1
4 13 1415.60 20 13.65 2274 621 2.84 / 34.80 1 2
5 13 1196.08 20 13.80 1976 545 3.39 / 35.34 1 2
6 13 472.68 20 14.35 989 284 3.67 / 35.63 1 2
7 13 43.32 20 14.80 375 111 3.78 / 35.74 2 2
8 14 0.00 190 14.45 296 813 4.60 / 36.55 2 13
Average= 4.06 (KJ/cycle)

Cycle 7 GMT 27/11/2014 15:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 26 14.83 457 176 0.18 / 27.14 2 2
2 7 2004.12 75 12.94 3170 3076 3.25 / 30.22 1 1
3 13 1002.48 20 13.93 1685 469 3.72 / 30.69 1 2
4 13 330.80 20 14.49 815 236 3.96 / 30.92 1 2
5 14 0.08 240 14.45 297 1030 4.99 / 31.95 1 19
Average= 3.99 (KJ/cycle)

Cycle 6 GMT 17/11/2014 16:30:58

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 24 14.83 449 160 0.16 / 22.14 2 2
2 3 1032.00 1 14.68 1903 28 0.19 / 22.17 1 1
3 3 1019.16 1 14.65 1888 28 0.22 / 22.19 1 1
4 7 2001.60 75 12.92 3151 3053 3.27 / 25.25 1 1
5 13 995.68 20 13.90 1685 468 3.74 / 25.72 1 2
6 13 314.52 20 14.49 785 227 3.96 / 25.94 1 2
7 14 -0.16 240 14.43 295 1022 4.99 / 26.96 1 19
Average= 3.85 (KJ/cycle)

Cycle 5 GMT 7/11/2014 17:18: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 24 14.78 457 162 0.16 / 17.23 2 2
2 7 2004.80 74 12.89 3149 3004 3.17 / 20.23 1 2
3 13 1013.60 20 13.86 1708 473 3.64 / 20.71 1 2
4 13 340.12 20 14.45 831 240 3.88 / 20.95 1 2
5 14 -0.12 241 14.42 297 1032 4.91 / 21.98 1 18
Average= 3.66 (KJ/cycle)

Cycle 4 GMT 28/10/2014 17:51: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 26 14.77 450 173 0.17 / 13.09 1 2
2 3 962.28 -1 14.77 450 0 0.00 / 13.09 1 2
3 3 1019.04 1 14.56 1875 27 0.20 / 13.12 1 1
4 7 1512.36 75 13.18 2416 2388 2.59 / 15.50 1 2
5 13 812.64 20 13.99 1447 405 2.99 / 15.91 1 2
6 13 85.08 20 14.73 439 129 3.12 / 16.04 1 2
7 14 -0.08 240 14.38 298 1028 4.15 / 17.07 2 16
Average= 3.41 (KJ/cycle)

Cycle 3 GMT 27/10/2014 18:22:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 27 14.71 461 183 0.18 / 8.89 2 2
2 3 926.72 -1 14.71 461 0 0.00 / 8.89 2 2
3 7 1501.84 75 13.10 2461 2418 2.60 / 11.31 2 2
4 13 788.08 20 13.95 1435 400 3.00 / 11.71 1 1
5 13 161.56 20 14.59 568 166 3.17 / 11.87 1 2
6 14 -0.08 240 14.38 302 1042 4.21 / 12.92 2 17
Average= 3.23 (KJ/cycle)

Cycle 2 GMT 26/10/2014 19: 3:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 24 14.69 451 159 0.16 / 4.62 2 2
2 10 1001.64 3 14.48 1811 79 0.24 / 4.70 1 2
3 3 1020.92 1 14.45 1857 27 0.26 / 4.73 1 1
4 7 1513.84 75 12.99 2443 2380 2.64 / 7.11 1 1
5 13 818.28 20 13.89 1438 399 3.04 / 7.51 1 1
6 13 176.12 20 14.52 580 168 3.21 / 7.68 1 2
7 14 0.00 240 14.35 299 1030 4.24 / 8.71 1 13
Average= 2.90 (KJ/cycle)

Cycle 1 GMT 25/10/2014 19:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 27 14.71 432 172 0.17 / 1.69 2 2
2 3 1021.84 1 14.11 1889 27 0.20 / 1.71 1 2
3 3 1024.28 1 14.08 1893 27 0.22 / 1.74 1 2
4 7 1012.40 74 13.25 1744 1710 1.93 / 3.45 2 2
5 14 -0.04 240 14.31 295 1013 2.95 / 4.46 2 19
Average= 2.23 (KJ/cycle)

Cycle 0 GMT 25/10/2014 8:24: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 98.56 26 14.73 410 157 0.16 / 0.16 2 2
2 7 104.80 75 14.40 415 448 0.61 / 0.61 2 2
3 14 0.16 240 14.48 262 911 1.52 / 1.52 2 18
Average= 1.52 (KJ/cycle)