SIO Argo Site:
Pump Diagnostics Page   



Serial= 8253 WMO= 5902344

Return

←PreviousNext→

Cycle 323 GMT 8/ 9/2022 10:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 44 10.61 499 233 0.23 / 1555.72 2 3
2 3 1024.52 1 8.12 1771 14 0.25 / 1555.74 2 2
3 3 1019.44 1 8.12 1762 14 0.26 / 1555.75 2 2
4 12 1155.40 5 7.34 1943 71 0.33 / 1555.82 2 2
5 12 1202.68 65 7.34 1998 953 1.29 / 1556.78 2 2
6 7 1208.52 24 7.39 2018 358 1.64 / 1557.13 2 2
7 13 1102.84 34 7.65 1899 494 2.14 / 1557.63 2 2
8 13 931.36 34 8.12 1668 461 2.60 / 1558.09 2 2
9 13 512.68 34 9.32 1081 343 2.94 / 1558.43 2 2
10 14 -0.12 190 10.79 338 693 3.63 / 1559.12 2 3
Average= 4.81 (KJ/cycle)

Cycle 322 GMT 29/ 8/2022 15:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 44 10.60 494 230 0.23 / 1552.13 2 3
2 12 1160.64 5 7.42 1952 72 0.30 / 1552.20 2 2
3 12 1203.28 65 7.39 1999 960 1.26 / 1553.16 2 2
4 7 1210.40 24 7.45 2005 358 1.62 / 1553.52 2 2
5 13 1111.32 33 7.67 1912 484 2.11 / 1554.00 2 2
6 13 933.68 33 8.15 1677 451 2.56 / 1554.45 2 2
7 13 513.80 33 9.32 1084 333 2.89 / 1554.79 2 2
8 14 -0.12 190 10.79 342 701 3.59 / 1555.49 2 3
Average= 4.82 (KJ/cycle)

Cycle 321 GMT 19/ 8/2022 20:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 43 10.63 493 225 0.23 / 1548.54 2 3
2 12 1137.64 5 7.59 1925 73 0.30 / 1548.61 2 2
3 12 1219.52 65 7.38 2035 976 1.27 / 1549.59 2 2
4 7 1225.08 25 7.39 2074 383 1.66 / 1549.97 2 2
5 13 1108.56 33 7.71 1930 491 2.15 / 1550.46 2 2
6 13 933.44 33 8.11 1692 453 2.60 / 1550.92 2 2
7 13 331.00 33 9.81 833 270 2.87 / 1551.19 2 2
8 14 0.00 191 10.80 345 712 3.58 / 1551.90 2 3
Average= 4.82 (KJ/cycle)

Cycle 320 GMT 10/ 8/2022 0:34: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 44 10.63 489 229 0.23 / 1542.20 2 3
2 12 1107.72 5 7.73 1896 73 0.30 / 1542.27 2 2
3 12 2002.72 65 5.35 3244 1128 1.43 / 1543.40 2 2
4 7 2005.36 24 5.45 3231 423 1.85 / 1543.82 2 2
5 13 1964.00 33 5.69 3092 581 2.43 / 1544.40 2 2
6 13 1871.68 33 5.85 2959 571 3.00 / 1544.97 2 2
7 13 1741.24 33 6.24 2768 570 3.57 / 1545.54 2 2
8 13 1572.80 33 6.61 2555 557 4.13 / 1546.10 2 2
9 13 1399.80 33 7.04 2326 540 4.67 / 1546.64 2 2
10 13 1013.52 33 8.00 1802 476 5.15 / 1547.12 2 2
11 13 599.72 33 9.07 1234 369 5.52 / 1547.49 2 2
12 13 19.44 33 10.78 367 131 5.65 / 1547.62 2 2
13 14 -0.20 190 10.83 339 698 6.35 / 1548.32 2 2
Average= 4.82 (KJ/cycle)

Cycle 319 GMT 8/ 8/2022 19:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 44 10.65 486 228 0.23 / 1538.56 2 2
2 12 1096.68 5 7.48 1872 70 0.30 / 1538.63 2 2
3 12 1201.36 65 7.39 2008 965 1.26 / 1539.59 2 2
4 7 1208.24 24 7.43 2053 366 1.63 / 1539.96 2 2
5 13 1110.92 34 7.71 1925 505 2.13 / 1540.46 2 2
6 13 940.28 34 8.09 1700 468 2.60 / 1540.93 2 2
7 13 511.36 34 9.30 1092 345 2.95 / 1541.28 2 2
8 14 0.00 190 10.81 337 692 3.64 / 1541.97 2 2
Average= 4.82 (KJ/cycle)

Cycle 318 GMT 30/ 7/2022 0:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 43 10.63 493 225 0.23 / 1534.97 2 3
2 3 1023.08 1 8.31 1765 15 0.24 / 1534.98 2 2
3 3 1019.32 1 8.32 1748 15 0.25 / 1535.00 2 2
4 12 1124.72 5 7.42 1918 71 0.33 / 1535.07 2 2
5 12 1202.16 65 7.42 2020 974 1.30 / 1536.04 2 2
6 7 1208.12 24 7.49 2059 370 1.67 / 1536.41 2 2
7 13 1079.24 34 7.83 1890 503 2.17 / 1536.91 2 2
8 13 909.48 34 8.25 1663 466 2.64 / 1537.38 2 2
9 13 302.28 34 9.94 785 265 2.91 / 1537.65 2 2
10 14 -0.20 190 10.84 333 686 3.59 / 1538.33 2 2
Average= 4.82 (KJ/cycle)

Cycle 317 GMT 20/ 7/2022 4:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 43 10.70 487 224 0.22 / 1531.34 2 3
2 12 1142.08 5 7.67 1917 74 0.30 / 1531.41 2 2
3 12 1204.20 65 7.53 2010 984 1.28 / 1532.39 2 2
4 7 1209.20 25 7.50 2058 386 1.67 / 1532.78 2 2
5 13 1093.32 33 7.83 1903 492 2.16 / 1533.27 2 2
6 13 903.12 33 8.33 1644 452 2.61 / 1533.72 2 2
7 13 475.32 33 9.51 1029 323 2.93 / 1534.05 2 2
8 14 0.00 190 10.83 338 696 3.63 / 1534.74 2 3
Average= 4.83 (KJ/cycle)

Cycle 316 GMT 10/ 7/2022 9:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 44 10.62 475 222 0.22 / 1525.57 2 3
2 12 1133.44 5 7.87 1918 75 0.30 / 1525.64 2 2
3 12 2006.80 65 5.61 3154 1150 1.45 / 1526.79 2 2
4 7 2007.04 25 5.58 3221 449 1.90 / 1527.24 2 2
5 13 1892.72 34 5.97 2993 608 2.50 / 1527.85 2 2
6 13 1758.88 34 6.28 2810 600 3.10 / 1528.45 2 2
7 13 1590.16 34 6.75 2581 592 3.70 / 1529.04 2 2
8 13 1406.88 34 7.20 2343 574 4.27 / 1529.61 2 2
9 13 1007.88 34 8.09 1809 498 4.77 / 1530.11 2 2
10 13 390.36 33 9.76 926 298 5.07 / 1530.41 2 2
11 14 -0.04 190 10.85 340 701 5.77 / 1531.11 2 3
Average= 4.83 (KJ/cycle)

Cycle 315 GMT 9/ 7/2022 5:23: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 43 10.66 487 223 0.22 / 1521.84 3 3
2 12 1149.56 5 7.44 1934 72 0.30 / 1521.92 2 2
3 12 1201.40 65 7.45 2022 979 1.27 / 1522.90 2 2
4 7 1206.52 24 7.45 2061 369 1.64 / 1523.26 2 2
5 13 1082.24 33 7.85 1889 489 2.13 / 1523.75 2 2
6 13 902.92 33 8.32 1643 451 2.58 / 1524.20 2 2
7 13 482.92 33 9.45 1054 329 2.91 / 1524.53 2 2
8 13 5.36 33 10.81 341 122 3.03 / 1524.66 2 2
9 14 0.04 190 10.83 335 689 3.72 / 1525.34 2 3
Average= 4.83 (KJ/cycle)

Cycle 314 GMT 29/ 6/2022 10: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 43 10.71 469 216 0.22 / 1518.28 2 3
2 12 1132.88 5 7.54 1909 72 0.29 / 1518.36 2 2
3 12 1221.24 65 7.45 2041 988 1.28 / 1519.34 2 2
4 7 1227.48 25 7.48 2083 390 1.67 / 1519.73 2 2
5 13 1101.04 33 7.83 1909 493 2.16 / 1520.23 2 2
6 13 922.56 33 8.29 1683 460 2.62 / 1520.69 2 2
7 13 290.84 33 10.01 763 252 2.87 / 1520.94 2 2
8 14 -0.12 190 10.85 331 682 3.55 / 1521.62 2 3
Average= 4.83 (KJ/cycle)

Cycle 313 GMT 19/ 6/2022 14:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 41 10.71 483 212 0.21 / 1514.74 3 3
2 3 1028.28 1 8.32 1799 15 0.23 / 1514.75 2 2
3 3 1019.52 1 8.46 1762 15 0.24 / 1514.77 2 2
4 12 1146.48 5 7.64 1940 74 0.32 / 1514.84 2 2
5 12 1214.60 65 7.54 2027 993 1.31 / 1515.84 2 2
6 7 1218.92 24 7.58 2036 370 1.68 / 1516.21 2 2
7 13 1086.72 33 7.91 1893 494 2.17 / 1516.70 2 2
8 13 905.68 33 8.35 1644 453 2.63 / 1517.15 2 2
9 13 264.00 33 10.10 721 240 2.87 / 1517.39 2 2
10 14 0.00 190 10.87 326 673 3.54 / 1518.07 2 4
Average= 4.83 (KJ/cycle)

Cycle 312 GMT 9/ 6/2022 19:11: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 41 10.67 475 208 0.21 / 1508.78 2 3
2 10 1015.24 2 8.28 1769 29 0.24 / 1508.81 2 2
3 12 1123.52 5 7.84 1909 75 0.31 / 1508.88 2 2
4 12 2004.12 65 5.54 3186 1147 1.46 / 1510.03 2 2
5 7 2004.12 24 5.46 3230 423 1.88 / 1510.45 2 2
6 13 1909.88 33 5.93 3031 593 2.48 / 1511.04 2 2
7 13 1783.56 33 6.38 2839 598 3.07 / 1511.64 2 2
8 13 1621.88 33 6.75 2621 584 3.66 / 1512.23 2 2
9 13 1455.28 33 7.05 2404 559 4.22 / 1512.78 2 2
10 13 1062.60 33 8.00 1864 492 4.71 / 1513.28 2 2
11 13 652.80 33 9.02 1318 392 5.10 / 1513.67 2 2
12 13 95.48 33 10.59 477 167 5.27 / 1513.84 2 2
13 14 -0.08 190 10.86 335 691 5.96 / 1514.53 2 3
Average= 4.84 (KJ/cycle)

Cycle 311 GMT 8/ 6/2022 15: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 43 10.66 478 219 0.22 / 1505.29 3 3
2 12 1124.84 5 7.46 1904 71 0.29 / 1505.36 2 2
3 12 1202.76 65 7.46 2013 976 1.27 / 1506.33 2 2
4 7 1208.16 25 7.45 2037 379 1.65 / 1506.71 2 2
5 13 1074.96 33 7.85 1877 486 2.13 / 1507.20 2 2
6 13 889.36 33 8.32 1626 446 2.58 / 1507.65 2 2
7 13 269.92 33 10.06 735 244 2.82 / 1507.89 2 2
8 14 -0.04 191 10.84 328 679 3.50 / 1508.57 2 3
Average= 4.84 (KJ/cycle)

Cycle 310 GMT 29/ 5/2022 19:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 41 10.70 478 210 0.21 / 1501.74 2 3
2 3 1045.84 1 8.43 1801 15 0.22 / 1501.76 2 2
3 3 1020.48 1 8.46 1782 15 0.24 / 1501.77 2 2
4 12 1144.08 5 7.62 1940 74 0.31 / 1501.85 2 2
5 12 1216.16 65 7.48 2026 985 1.30 / 1502.83 2 2
6 7 1221.36 24 7.50 2047 368 1.67 / 1503.20 2 2
7 13 1103.88 33 7.83 1914 495 2.16 / 1503.69 2 2
8 13 911.36 33 8.31 1649 452 2.61 / 1504.15 2 2
9 13 280.92 33 10.04 752 249 2.86 / 1504.39 2 2
10 14 0.00 190 10.85 326 672 3.54 / 1505.07 2 4
Average= 4.84 (KJ/cycle)

Cycle 309 GMT 20/ 5/2022 0:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 41 10.92 464 208 0.21 / 1498.22 3 3
2 12 1110.48 5 7.93 1897 75 0.28 / 1498.30 2 2
3 12 1211.08 65 7.59 2026 1000 1.28 / 1499.30 2 2
4 7 1216.00 24 7.51 2066 372 1.65 / 1499.67 2 2
5 13 1072.88 33 7.99 1874 494 2.15 / 1500.16 2 2
6 13 886.56 33 8.46 1616 451 2.60 / 1500.61 2 2
7 13 270.44 33 10.10 738 246 2.85 / 1500.86 2 2
8 14 -0.12 190 10.88 325 672 3.52 / 1501.53 2 3
Average= 4.84 (KJ/cycle)

Cycle 308 GMT 10/ 5/2022 4:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 41 11.04 465 210 0.21 / 1492.81 3 3
2 12 1109.08 5 8.58 1922 82 0.29 / 1492.89 2 2
3 12 2002.16 65 6.40 3152 1311 1.60 / 1494.21 2 2
4 7 2001.60 24 6.39 3138 481 2.09 / 1494.69 2 2
5 13 1868.32 33 6.70 2967 656 2.74 / 1495.34 2 2
6 13 1673.16 33 7.12 2709 637 3.38 / 1495.98 2 2
7 13 1480.00 33 7.51 2448 607 3.98 / 1496.59 2 2
8 13 1043.20 33 8.46 1848 516 4.50 / 1497.10 2 2
9 13 209.32 33 10.50 640 222 4.72 / 1497.32 2 2
10 14 0.00 190 11.03 329 689 5.41 / 1498.01 2 3
Average= 4.85 (KJ/cycle)

Cycle 307 GMT 9/ 5/2022 1: 9: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 41 11.07 482 219 0.22 / 1489.18 3 3
2 12 1123.56 5 8.00 1904 76 0.29 / 1489.26 2 2
3 12 1204.56 65 7.71 2028 1016 1.31 / 1490.27 2 2
4 7 1209.64 24 7.72 2064 382 1.69 / 1490.65 2 2
5 13 1085.52 33 8.24 1893 515 2.21 / 1491.17 2 2
6 13 701.92 33 9.19 1368 415 2.62 / 1491.58 2 2
7 13 149.48 33 10.75 550 195 2.82 / 1491.78 2 2
8 13 35.64 33 11.08 373 136 2.95 / 1491.92 2 2
9 14 -0.12 190 11.14 324 686 3.64 / 1492.60 2 3
Average= 4.85 (KJ/cycle)

Cycle 306 GMT 29/ 4/2022 5:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 41 11.16 476 218 0.22 / 1485.63 3 3
2 12 1139.68 5 8.01 1933 77 0.30 / 1485.71 2 2
3 12 1215.32 65 7.83 2043 1040 1.34 / 1486.75 2 2
4 7 1219.68 24 7.84 2076 391 1.73 / 1487.14 2 2
5 13 1070.16 33 8.40 1875 520 2.25 / 1487.66 2 2
6 13 690.84 33 9.31 1358 417 2.66 / 1488.08 2 2
7 13 130.52 33 10.84 522 187 2.85 / 1488.26 2 2
8 14 -0.08 190 11.16 329 698 3.55 / 1488.96 2 3
Average= 4.85 (KJ/cycle)

Cycle 305 GMT 19/ 4/2022 10:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 37 11.18 478 198 0.20 / 1481.85 3 3
2 10 1009.52 2 9.24 1788 33 0.23 / 1481.88 2 2
3 3 1038.24 1 9.13 1822 17 0.25 / 1481.90 2 2
4 3 1030.40 1 9.13 1791 16 0.26 / 1481.92 2 2
5 12 1137.36 5 8.23 1920 79 0.34 / 1481.99 2 2
6 12 1212.76 65 8.00 2055 1069 1.41 / 1483.06 2 2
7 7 1218.24 25 7.97 2089 416 1.83 / 1483.48 2 2
8 13 1068.24 33 8.53 1880 529 2.36 / 1484.01 2 2
9 13 871.32 33 9.00 1615 480 2.84 / 1484.49 2 2
10 13 190.92 33 10.77 629 224 3.06 / 1484.71 2 2
11 14 -0.12 190 11.21 330 703 3.76 / 1485.41 2 3
Average= 4.85 (KJ/cycle)

Cycle 304 GMT 9/ 4/2022 15: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 37 11.13 480 198 0.20 / 1476.48 2 3
2 3 1095.28 2 8.78 1888 33 0.23 / 1476.51 2 2
3 3 1056.92 1 8.78 1838 16 0.25 / 1476.53 2 2
4 12 1145.16 5 8.52 1946 83 0.33 / 1476.61 2 2
5 12 2004.00 65 6.22 3164 1279 1.61 / 1477.89 2 2
6 7 2003.84 25 6.22 3144 489 2.10 / 1478.38 2 2
7 13 1866.48 34 6.91 2976 699 2.80 / 1479.08 2 2
8 13 1689.04 33 7.29 2736 658 3.46 / 1479.74 2 2
9 13 1293.16 33 8.22 2205 598 4.05 / 1480.33 2 2
10 13 696.28 33 9.53 1382 435 4.49 / 1480.77 2 2
11 13 80.92 33 11.12 459 168 4.66 / 1480.94 2 2
12 14 -0.04 190 11.24 334 713 5.37 / 1481.65 2 3
Average= 4.86 (KJ/cycle)

Cycle 303 GMT 8/ 4/2022 11:14: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 41 11.17 486 223 0.22 / 1472.72 3 3
2 12 1130.92 5 8.05 1930 78 0.30 / 1472.80 2 2
3 12 1203.08 65 7.78 2012 1017 1.32 / 1473.82 2 2
4 7 1208.32 24 7.80 2046 383 1.70 / 1474.20 2 2
5 13 1065.24 33 8.43 1875 522 2.22 / 1474.72 2 2
6 13 874.48 33 8.92 1635 481 2.70 / 1475.20 2 2
7 13 209.36 33 10.69 661 233 2.94 / 1475.44 2 2
8 13 14.76 33 11.26 351 130 3.07 / 1475.57 2 2
9 14 0.08 190 11.18 336 714 3.78 / 1476.28 2 2
Average= 4.86 (KJ/cycle)

Cycle 302 GMT 29/ 3/2022 16: 4: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 37 11.31 477 200 0.20 / 1469.03 3 3
2 10 1048.08 3 9.34 1853 52 0.25 / 1469.08 2 2
3 3 1034.00 1 9.34 1804 17 0.27 / 1469.10 2 2
4 3 1021.16 1 9.17 1802 17 0.28 / 1469.11 2 2
5 12 1133.80 5 8.34 1936 81 0.37 / 1469.19 2 2
6 12 1211.76 65 7.98 2028 1052 1.42 / 1470.24 2 2
7 7 1216.44 24 7.97 2046 391 1.81 / 1470.64 2 2
8 13 1066.00 33 8.59 1888 535 2.34 / 1471.17 2 2
9 13 685.92 33 9.52 1360 427 2.77 / 1471.60 2 2
10 13 113.68 33 11.00 518 188 2.96 / 1471.79 2 2
11 14 -0.16 190 11.25 334 714 3.67 / 1472.50 2 3
Average= 4.86 (KJ/cycle)

Cycle 301 GMT 19/ 3/2022 20:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 37 11.87 476 209 0.21 / 1465.23 3 3
2 12 1123.64 5 8.57 1924 82 0.29 / 1465.31 2 2
3 12 1207.08 65 8.09 2027 1066 1.36 / 1466.37 2 2
4 7 1211.60 25 8.20 2041 418 1.78 / 1466.79 2 2
5 13 1046.84 34 8.91 1853 561 2.34 / 1467.35 2 2
6 13 634.92 34 9.78 1292 430 2.77 / 1467.78 2 2
7 13 85.84 34 11.24 469 179 2.95 / 1467.96 2 2
8 13 1.52 34 11.49 339 132 3.08 / 1468.10 2 3
9 14 -0.08 190 11.36 339 732 3.81 / 1468.83 2 3
Average= 4.86 (KJ/cycle)

Cycle 300 GMT 10/ 3/2022 1:33: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 38 12.01 473 216 0.22 / 1459.69 3 3
2 3 970.44 -1 12.01 473 0 0.00 / 1459.69 3 3
3 3 1042.20 1 9.39 1832 17 0.23 / 1459.70 2 2
4 12 1138.40 5 9.19 1992 92 0.32 / 1459.80 2 2
5 12 2002.28 65 6.71 3167 1381 1.71 / 1461.18 2 2
6 7 1999.68 24 6.73 3153 509 2.22 / 1461.69 2 2
7 13 1815.64 34 7.45 2917 739 2.95 / 1462.43 2 2
8 13 1620.48 34 8.00 2662 724 3.68 / 1463.15 2 2
9 13 1210.20 34 8.89 2093 633 4.31 / 1463.78 2 2
10 13 392.40 34 10.63 942 340 4.65 / 1464.12 2 2
11 13 31.64 34 11.73 382 152 4.80 / 1464.27 2 2
12 14 -0.12 190 11.59 337 742 5.55 / 1465.02 2 3
Average= 4.87 (KJ/cycle)

Cycle 299 GMT 8/ 3/2022 21:48: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 37 12.17 482 217 0.22 / 1456.03 3 3
2 12 1119.36 5 7.61 1874 71 0.29 / 1456.10 2 2
3 12 1205.76 65 7.08 2017 928 1.22 / 1457.03 2 2
4 7 1212.00 24 7.32 2050 360 1.58 / 1457.39 2 2
5 13 1101.28 33 8.53 1934 544 2.12 / 1457.93 2 2
6 13 909.32 33 9.13 1679 506 2.63 / 1458.44 2 2
7 13 271.84 33 10.99 752 273 2.90 / 1458.71 2 2
8 14 -0.16 190 11.85 339 763 3.66 / 1459.47 2 3
Average= 4.86 (KJ/cycle)

Cycle 298 GMT 27/ 2/2022 2:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 35 12.32 471 203 0.20 / 1452.31 3 3
2 3 1021.96 1 9.80 1812 18 0.22 / 1452.33 2 2
3 3 1036.20 1 9.79 1832 18 0.24 / 1452.35 2 2
4 12 1139.56 5 8.23 1926 79 0.32 / 1452.43 2 2
5 12 1202.12 65 7.71 2008 1006 1.32 / 1453.43 2 2
6 7 1207.48 24 7.76 2016 375 1.70 / 1453.81 2 2
7 13 1067.36 33 8.94 1881 555 2.25 / 1454.36 2 2
8 13 690.32 33 10.14 1372 459 2.71 / 1454.82 2 2
9 13 115.00 33 12.02 521 207 2.92 / 1455.03 2 2
10 14 0.00 190 12.12 339 781 3.70 / 1455.81 2 3
Average= 4.87 (KJ/cycle)

Cycle 297 GMT 17/ 2/2022 7: 6: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 33 12.34 484 197 0.20 / 1448.36 3 3
2 3 1095.08 2 10.51 1933 41 0.24 / 1448.40 2 2
3 3 1052.56 1 10.46 1880 20 0.26 / 1448.42 2 2
4 12 1143.96 5 9.41 1940 91 0.35 / 1448.51 2 2
5 12 1216.24 65 8.71 2072 1173 1.52 / 1449.68 2 2
6 7 1220.92 24 8.61 2081 430 1.95 / 1450.11 2 2
7 13 1037.64 34 9.60 1864 608 2.56 / 1450.72 2 2
8 13 603.64 34 10.63 1256 454 3.01 / 1451.17 2 2
9 13 13.44 34 12.59 360 154 3.17 / 1451.33 2 3
10 14 -0.20 191 12.06 339 781 3.95 / 1452.11 2 3
Average= 4.87 (KJ/cycle)

Cycle 296 GMT 7/ 2/2022 12: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.80 32 12.33 504 199 0.20 / 1442.89 3 3
2 10 1015.56 3 10.77 1838 59 0.26 / 1442.95 2 2
3 3 1070.96 2 10.54 1902 40 0.30 / 1442.99 2 2
4 3 1035.80 1 10.40 1846 19 0.32 / 1443.01 2 2
5 12 1146.44 5 10.29 1987 102 0.42 / 1443.11 2 2
6 12 2001.20 65 7.77 3182 1607 2.03 / 1444.72 2 2
7 7 1996.88 25 7.34 3135 575 2.60 / 1445.30 2 2
8 13 1619.56 33 8.93 2668 786 3.39 / 1446.08 2 2
9 13 1200.32 33 9.78 2106 680 4.07 / 1446.76 2 2
10 13 531.00 33 11.10 1162 426 4.49 / 1447.19 2 2
11 13 48.80 33 12.38 421 172 4.67 / 1447.36 2 2
12 14 -0.04 190 12.20 344 797 5.46 / 1448.16 2 3
Average= 4.88 (KJ/cycle)

Cycle 295 GMT 6/ 2/2022 8:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 35 12.88 485 219 0.22 / 1439.07 3 3
2 3 1018.80 1 11.12 1834 20 0.24 / 1439.09 2 2
3 12 1123.44 5 7.99 1900 76 0.31 / 1439.16 2 2
4 12 1209.84 65 7.76 2025 1021 1.34 / 1440.19 2 2
5 7 1215.20 25 8.36 2074 433 1.77 / 1440.62 2 2
6 13 1071.84 33 9.56 1907 602 2.37 / 1441.22 2 2
7 13 672.52 33 10.78 1358 483 2.85 / 1441.70 2 2
8 13 44.32 33 12.47 422 174 3.03 / 1441.88 2 2
9 14 0.00 190 12.34 349 818 3.85 / 1442.70 2 3
Average= 4.87 (KJ/cycle)

Cycle 294 GMT 27/ 1/2022 13:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 32 13.05 514 215 0.21 / 1435.12 2 3
2 3 1062.60 2 11.77 1905 45 0.26 / 1435.17 2 2
3 3 1019.64 1 11.38 1851 21 0.28 / 1435.19 2 2
4 12 1135.56 5 6.45 1916 62 0.34 / 1435.25 2 2
5 12 1211.72 65 6.79 2002 884 1.23 / 1436.13 2 2
6 7 1218.92 24 8.32 2058 411 1.64 / 1436.55 2 2
7 13 1108.52 34 9.45 1955 628 2.27 / 1437.17 2 2
8 13 912.32 34 10.28 1697 593 2.86 / 1437.77 2 2
9 13 114.24 34 12.77 527 229 3.09 / 1438.00 2 2
10 14 0.12 190 12.79 351 853 3.94 / 1438.85 2 3
Average= 4.88 (KJ/cycle)

Cycle 293 GMT 17/ 1/2022 18:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 32 13.50 523 226 0.23 / 1431.16 3 3
2 3 1020.36 1 11.67 1856 22 0.25 / 1431.18 2 2
3 12 1140.36 5 7.37 1935 71 0.32 / 1431.25 2 2
4 12 1213.20 65 7.45 2029 983 1.30 / 1432.24 2 2
5 7 1217.48 24 8.90 2056 439 1.74 / 1432.67 2 2
6 13 1064.80 33 10.03 1909 632 2.37 / 1433.31 2 2
7 13 635.88 33 11.50 1326 503 2.88 / 1433.81 2 2
8 13 69.72 33 13.03 474 204 3.08 / 1434.01 2 2
9 14 -0.16 190 12.94 364 895 3.97 / 1434.91 2 5
Average= 4.88 (KJ/cycle)

Cycle 292 GMT 7/ 1/2022 23: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 32 13.74 509 224 0.22 / 1425.76 3 3
2 12 1136.64 5 11.29 2022 114 0.34 / 1425.87 2 2
3 12 2007.64 65 8.59 3194 1783 2.12 / 1427.66 2 2
4 7 2004.08 25 8.65 3206 693 2.81 / 1428.35 2 2
5 13 1381.08 34 10.76 2386 873 3.69 / 1429.22 2 2
6 13 745.04 34 11.92 1487 603 4.29 / 1429.82 2 2
7 13 25.20 34 13.40 410 187 4.48 / 1430.01 2 2
8 14 0.00 190 13.17 369 923 5.40 / 1430.93 2 6
Average= 4.88 (KJ/cycle)

Cycle 291 GMT 6/ 1/2022 19:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 32 13.82 519 230 0.23 / 1421.29 2 3
2 12 1118.76 5 4.90 1767 43 0.27 / 1421.33 2 3
3 12 1207.72 65 5.17 1952 656 0.93 / 1421.99 2 3
4 7 1215.68 24 8.02 2042 393 1.32 / 1422.38 3 2
5 13 1318.48 33 8.75 2226 643 1.96 / 1423.02 2 2
6 13 1183.28 33 9.76 2077 669 2.63 / 1423.69 2 2
7 13 988.44 33 10.64 1818 638 3.27 / 1424.33 2 2
8 13 133.48 33 13.52 583 260 3.53 / 1424.59 2 2
9 14 -0.08 190 13.46 369 944 4.48 / 1425.53 2 6
Average= 4.88 (KJ/cycle)

Cycle 290 GMT 27/12/2021 23:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 32 13.98 519 232 0.23 / 1417.21 3 3
2 12 1128.76 5 4.94 1906 47 0.28 / 1417.26 2 3
3 12 1215.44 65 5.65 1983 728 1.01 / 1417.99 2 2
4 7 1221.76 24 8.31 2074 414 1.42 / 1418.40 2 2
5 13 1189.84 33 9.69 2075 664 2.08 / 1419.06 2 2
6 13 997.96 33 10.86 1815 650 2.74 / 1419.72 2 2
7 13 353.64 33 13.09 910 393 3.13 / 1420.11 2 2
8 14 -0.16 190 13.55 369 950 4.08 / 1421.06 2 4
Average= 4.88 (KJ/cycle)

Cycle 289 GMT 18/12/2021 4: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 32 14.07 503 226 0.23 / 1413.16 3 3
2 12 1114.84 5 7.30 1858 68 0.29 / 1413.23 2 2
3 12 1211.56 65 6.93 2008 905 1.20 / 1414.13 2 2
4 7 1217.16 24 8.89 2077 443 1.64 / 1414.58 2 2
5 13 1101.12 33 10.60 1969 689 2.33 / 1415.26 2 2
6 13 705.16 33 12.27 1417 574 2.90 / 1415.84 2 2
7 13 23.48 33 14.02 410 190 3.09 / 1416.03 2 2
8 14 0.00 190 13.70 366 953 4.05 / 1416.98 2 6
Average= 4.89 (KJ/cycle)

Cycle 288 GMT 8/12/2021 8:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 32 13.98 511 229 0.23 / 1407.68 3 3
2 12 1126.16 5 11.00 1994 110 0.34 / 1407.79 2 2
3 12 2004.16 65 8.63 3196 1793 2.13 / 1409.58 2 2
4 7 1999.64 24 9.24 3205 711 2.84 / 1410.29 2 2
5 13 1375.52 33 11.59 2339 895 3.74 / 1411.19 2 2
6 13 693.72 33 12.82 1401 593 4.33 / 1411.78 2 2
7 13 16.72 33 14.11 399 186 4.51 / 1411.97 2 2
8 14 -0.12 190 13.75 370 967 5.48 / 1412.93 2 8
Average= 4.89 (KJ/cycle)

Cycle 287 GMT 7/12/2021 5: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 32 14.06 498 224 0.22 / 1403.56 2 3
2 12 1126.20 5 4.91 1785 44 0.27 / 1403.60 2 3
3 12 1209.84 65 5.65 1978 726 0.99 / 1404.33 2 2
4 7 1217.72 25 8.54 2058 439 1.43 / 1404.77 2 2
5 13 1175.36 34 10.30 2065 723 2.16 / 1405.49 2 2
6 13 994.32 34 11.24 1832 700 2.86 / 1406.19 2 2
7 13 179.12 34 13.66 643 299 3.16 / 1406.49 2 2
8 14 -0.12 190 13.81 366 960 4.12 / 1407.45 2 5
Average= 4.89 (KJ/cycle)

Cycle 286 GMT 27/11/2021 9:30:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 32 14.03 505 227 0.23 / 1399.48 2 3
2 12 1130.24 5 4.96 1979 49 0.28 / 1399.53 2 3
3 12 1203.44 65 6.13 1981 789 1.07 / 1400.32 2 2
4 7 1210.68 24 8.68 2057 429 1.49 / 1400.75 2 2
5 13 1132.52 33 10.57 2013 702 2.20 / 1401.45 2 2
6 13 950.12 33 11.45 1775 671 2.87 / 1402.12 2 2
7 13 115.24 33 13.84 542 248 3.11 / 1402.37 2 2
8 14 -0.04 191 13.86 365 966 4.08 / 1403.34 2 8
Average= 4.89 (KJ/cycle)

Cycle 285 GMT 17/11/2021 14:16: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 32 14.03 521 234 0.23 / 1395.55 3 3
2 12 1124.16 5 6.90 1883 65 0.30 / 1395.61 2 2
3 12 1203.52 65 7.24 2000 941 1.24 / 1396.55 2 2
4 7 1209.76 24 9.15 2041 448 1.69 / 1397.00 2 2
5 13 1077.80 33 11.16 1944 716 2.40 / 1397.72 2 2
6 13 651.80 33 12.60 1332 554 2.96 / 1398.27 2 2
7 14 -0.08 190 13.85 374 984 3.94 / 1399.26 2 4
Average= 4.89 (KJ/cycle)

Cycle 284 GMT 7/11/2021 19: 7:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 32 14.00 500 224 0.22 / 1390.05 3 3
2 12 1126.80 5 11.16 1980 110 0.33 / 1390.16 2 2
3 12 2002.40 65 8.70 3189 1803 2.14 / 1391.97 2 2
4 7 1997.84 25 9.35 3219 752 2.89 / 1392.72 2 2
5 13 1554.04 34 11.45 2633 1025 3.92 / 1393.74 2 2
6 13 640.00 34 13.03 1318 584 4.50 / 1394.33 2 2
7 14 0.04 190 13.91 373 986 5.49 / 1395.31 2 3
Average= 4.90 (KJ/cycle)

Cycle 283 GMT 6/11/2021 15:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 32 14.10 507 229 0.23 / 1385.96 3 3
2 12 1135.32 5 4.92 1805 44 0.27 / 1386.00 2 3
3 12 1214.16 65 5.57 1979 716 0.99 / 1386.72 2 3
4 7 1220.88 24 8.38 2047 412 1.40 / 1387.13 3 2
5 13 1197.64 33 10.52 2085 724 2.13 / 1387.85 2 2
6 13 1040.04 33 11.26 1896 705 2.83 / 1388.56 2 2
7 13 197.48 33 13.65 674 304 3.13 / 1388.86 2 2
8 14 -0.08 190 13.92 365 965 4.10 / 1389.83 2 7
Average= 4.89 (KJ/cycle)

Cycle 282 GMT 27/10/2021 20: 2: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 32 14.12 507 229 0.23 / 1381.86 2 3
2 12 1134.68 5 4.92 1803 44 0.27 / 1381.90 2 3
3 12 1203.72 65 5.85 1971 749 1.02 / 1382.65 2 2
4 7 1211.00 24 8.62 2036 421 1.44 / 1383.07 2 2
5 13 1165.40 34 10.63 2043 738 2.18 / 1383.81 2 2
6 13 979.12 34 11.52 1799 705 2.89 / 1384.52 2 2
7 13 71.64 34 14.01 483 230 3.12 / 1384.75 2 2
8 14 0.04 190 14.02 369 983 4.10 / 1385.73 2 6
Average= 4.90 (KJ/cycle)

Cycle 281 GMT 18/10/2021 0:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 32 14.21 525 239 0.24 / 1377.69 2 3
2 12 1123.88 5 4.97 2066 51 0.29 / 1377.74 2 2
3 12 1206.60 65 7.02 2000 913 1.20 / 1378.65 2 2
4 7 1213.32 24 9.12 2082 456 1.66 / 1379.11 2 2
5 13 1094.88 33 11.27 1969 732 2.39 / 1379.84 2 2
6 13 690.24 34 12.69 1392 601 2.99 / 1380.44 2 2
7 13 13.72 33 14.15 393 184 3.17 / 1380.63 2 2
8 14 -0.04 190 14.05 376 1004 4.18 / 1381.63 2 5
Average= 4.90 (KJ/cycle)

Cycle 280 GMT 8/10/2021 5:22: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 32 14.17 519 235 0.24 / 1372.38 2 2
2 12 1110.00 5 11.25 1973 111 0.35 / 1372.49 2 2
3 12 2002.24 65 8.49 3175 1752 2.10 / 1374.24 2 2
4 7 1996.80 25 9.54 3207 765 2.86 / 1375.01 2 2
5 13 1361.88 33 12.15 2353 943 3.81 / 1375.95 2 2
6 13 491.24 33 13.49 1106 492 4.30 / 1376.45 2 2
7 14 0.00 190 14.19 373 1006 5.30 / 1377.45 2 4
Average= 4.90 (KJ/cycle)

Cycle 279 GMT 7/10/2021 1:51:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 32 14.13 518 234 0.23 / 1368.08 2 2
2 12 1130.20 5 4.87 1605 39 0.27 / 1368.12 2 3
3 12 1209.00 65 5.28 1970 676 0.95 / 1368.79 2 3
4 7 1217.96 24 8.55 2056 422 1.37 / 1369.21 3 2
5 13 1250.88 33 10.42 2172 747 2.12 / 1369.96 2 2
6 13 1081.32 33 11.35 1956 733 2.85 / 1370.69 2 2
7 13 426.40 33 13.42 1014 449 3.30 / 1371.14 2 2
8 14 0.00 190 14.15 373 1003 4.30 / 1372.15 2 6
Average= 4.90 (KJ/cycle)

Cycle 278 GMT 27/ 9/2021 6:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 32 14.19 516 234 0.23 / 1363.92 2 3
2 12 1130.80 5 4.87 1622 39 0.27 / 1363.96 2 3
3 12 1200.60 65 5.55 1965 709 0.98 / 1364.67 2 2
4 7 1207.12 24 8.73 2042 428 1.41 / 1365.09 2 2
5 13 1169.56 34 10.82 2042 751 2.16 / 1365.85 2 2
6 13 986.88 34 11.69 1802 716 2.88 / 1366.56 2 2
7 13 152.96 34 13.97 602 286 3.16 / 1366.85 2 2
8 14 -0.24 190 14.17 370 996 4.16 / 1367.84 2 11
Average= 4.90 (KJ/cycle)

Cycle 277 GMT 17/ 9/2021 10:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 31 14.18 513 226 0.23 / 1359.88 2 3
2 3 1035.64 1 11.58 1861 22 0.25 / 1359.91 2 2
3 12 1111.80 5 4.93 1862 46 0.29 / 1359.95 2 3
4 12 1237.24 65 6.54 2045 869 1.16 / 1360.82 2 2
5 7 1244.52 24 9.21 2100 464 1.63 / 1361.29 2 2
6 13 1126.44 34 11.38 2009 777 2.40 / 1362.06 2 2
7 13 725.60 34 12.80 1450 631 3.03 / 1362.69 2 2
8 14 0.00 190 14.20 367 990 4.02 / 1363.68 2 3
Average= 4.91 (KJ/cycle)

Cycle 276 GMT 7/ 9/2021 15:22: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 32 14.16 510 231 0.23 / 1354.63 3 3
2 12 1109.12 5 11.19 1969 110 0.34 / 1354.74 2 2
3 12 2003.40 65 8.32 3190 1725 2.07 / 1356.47 2 2
4 7 1998.44 24 9.67 3225 748 2.81 / 1357.21 2 2
5 13 1356.08 33 12.32 2327 946 3.76 / 1358.16 2 2
6 13 480.28 33 13.54 1105 494 4.25 / 1358.65 2 2
7 14 0.04 190 14.22 372 1005 5.26 / 1359.66 2 4
Average= 4.91 (KJ/cycle)

Cycle 275 GMT 6/ 9/2021 11:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 32 14.15 520 235 0.24 / 1350.47 2 3
2 12 1123.56 5 4.86 1604 39 0.27 / 1350.51 2 3
3 12 1215.28 65 5.36 1979 689 0.96 / 1351.20 2 2
4 7 1224.32 24 8.65 2072 430 1.39 / 1351.63 2 2
5 13 1211.40 33 10.80 2132 760 2.15 / 1352.39 2 2
6 13 1021.52 33 11.75 1855 719 2.87 / 1353.11 2 2
7 13 176.16 33 13.92 646 297 3.17 / 1353.41 2 2
8 14 -0.16 190 14.20 367 990 4.16 / 1354.40 2 7
Average= 4.91 (KJ/cycle)

Cycle 274 GMT 27/ 8/2021 16: 7: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 32 14.18 512 232 0.23 / 1346.31 2 3
2 3 968.16 -1 14.18 512 0 0.00 / 1346.31 2 3
3 3 1022.20 1 11.04 1845 20 0.25 / 1346.33 2 2
4 12 1145.76 5 4.87 1612 39 0.29 / 1346.37 2 3
5 12 1206.36 65 5.65 1978 726 1.02 / 1347.10 2 2
6 7 1214.04 24 8.81 2050 433 1.45 / 1347.53 2 2
7 13 1151.76 33 11.05 2046 746 2.20 / 1348.27 2 2
8 13 956.08 33 11.96 1775 701 2.90 / 1348.98 2 2
9 13 127.52 33 14.00 565 261 3.16 / 1349.24 2 2
10 14 0.00 190 14.18 372 1002 4.16 / 1350.24 2 7
Average= 4.91 (KJ/cycle)

Cycle 273 GMT 17/ 8/2021 20:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 32 14.19 516 234 0.23 / 1342.30 3 3
2 3 971.80 -1 14.19 516 0 0.00 / 1342.30 3 3
3 12 1161.52 5 4.94 1889 47 0.28 / 1342.34 2 3
4 12 1206.60 65 7.00 1997 909 1.19 / 1343.25 2 2
5 7 1213.56 24 9.23 2101 465 1.66 / 1343.72 2 2
6 13 1104.76 33 11.56 1963 749 2.40 / 1344.47 2 2
7 13 673.32 33 12.93 1374 586 2.99 / 1345.05 2 2
8 14 -0.12 190 14.17 381 1026 4.02 / 1346.08 2 4
Average= 4.91 (KJ/cycle)

Cycle 272 GMT 8/ 8/2021 1:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 33 14.16 514 240 0.24 / 1336.80 3 3
2 3 954.36 -1 14.16 514 0 0.00 / 1336.80 3 3
3 3 1034.92 1 11.19 1864 21 0.26 / 1336.82 2 2
4 12 1125.16 5 11.18 2009 112 0.37 / 1336.94 2 2
5 12 2000.72 65 8.39 3195 1742 2.12 / 1338.68 2 2
6 7 1994.96 24 9.72 3216 750 2.87 / 1339.43 2 2
7 13 1546.60 33 12.10 2586 1033 3.90 / 1340.46 2 2
8 13 639.52 33 13.35 1326 584 4.48 / 1341.05 2 2
9 14 -0.08 190 14.24 375 1015 5.50 / 1342.06 2 5
Average= 4.92 (KJ/cycle)

Cycle 271 GMT 6/ 8/2021 22:45: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 32 14.16 526 238 0.24 / 1332.50 3 3
2 12 1099.92 5 4.85 1550 38 0.28 / 1332.53 2 3
3 12 1222.36 66 5.19 1988 681 0.96 / 1333.21 2 2
4 7 1231.68 24 8.87 2080 443 1.40 / 1333.66 2 2
5 13 1256.16 34 10.81 2189 805 2.20 / 1334.46 2 2
6 13 1079.12 34 11.75 1942 776 2.98 / 1335.24 2 2
7 13 188.64 34 13.89 669 316 3.30 / 1335.55 2 2
8 14 -0.12 190 14.19 375 1011 4.31 / 1336.56 2 6
Average= 4.91 (KJ/cycle)

Cycle 270 GMT 28/ 7/2021 2:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 33 14.17 530 248 0.25 / 1328.28 2 3
2 3 973.28 -1 14.17 530 0 0.00 / 1328.28 2 3
3 3 1045.76 1 11.25 1880 21 0.27 / 1328.30 2 2
4 12 1147.36 5 4.86 1559 38 0.31 / 1328.34 2 3
5 12 1200.68 65 5.60 1971 717 1.02 / 1329.06 2 2
6 7 1207.96 25 8.84 2060 455 1.48 / 1329.51 2 2
7 13 1157.64 34 11.15 2066 783 2.26 / 1330.30 2 2
8 13 957.72 34 12.07 1780 730 2.99 / 1331.03 2 2
9 13 70.64 34 14.11 483 232 3.22 / 1331.26 2 3
10 14 0.04 190 14.20 370 998 4.22 / 1332.26 2 14
Average= 4.92 (KJ/cycle)

Cycle 269 GMT 18/ 7/2021 7:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 32 14.19 515 234 0.23 / 1324.19 3 3
2 12 1129.76 5 4.92 1850 46 0.28 / 1324.24 2 3
3 12 1203.40 65 6.90 2006 900 1.18 / 1325.14 2 2
4 7 1210.44 25 9.30 2100 488 1.67 / 1325.62 2 2
5 13 1101.84 34 11.64 1963 777 2.44 / 1326.40 2 2
6 13 701.84 34 12.96 1413 623 3.07 / 1327.02 2 2
7 14 -0.08 190 14.22 374 1010 4.08 / 1328.03 2 4
Average= 4.92 (KJ/cycle)

Cycle 268 GMT 8/ 7/2021 12:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 33 14.18 514 241 0.24 / 1318.83 2 3
2 12 1111.72 5 11.09 1969 109 0.35 / 1318.94 2 2
3 12 2002.04 65 8.42 3183 1742 2.09 / 1320.68 2 2
4 7 1997.84 25 9.79 3224 789 2.88 / 1321.47 2 2
5 13 1382.36 33 12.39 2361 965 3.85 / 1322.43 2 2
6 13 499.68 33 13.57 1122 502 4.35 / 1322.94 2 2
7 14 -0.08 190 14.25 377 1021 5.37 / 1323.96 2 5
Average= 4.92 (KJ/cycle)

Cycle 267 GMT 7/ 7/2021 8:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 33 14.15 516 241 0.24 / 1314.56 3 3
2 12 1104.20 5 4.85 1522 37 0.28 / 1314.60 2 3
3 12 1224.08 65 5.10 1984 658 0.94 / 1315.26 2 3
4 7 1233.28 24 8.74 2078 436 1.37 / 1315.69 3 2
5 13 1276.04 33 10.85 2212 792 2.16 / 1316.48 2 2
6 13 1097.92 33 11.85 1961 767 2.93 / 1317.25 2 2
7 13 232.24 33 13.83 731 334 3.26 / 1317.59 2 2
8 14 -0.04 190 14.21 371 1002 4.27 / 1318.59 2 5
Average= 4.92 (KJ/cycle)

Cycle 266 GMT 27/ 6/2021 13: 1: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 33 14.15 528 247 0.25 / 1310.37 3 3
2 3 963.72 -1 14.15 528 0 0.00 / 1310.37 3 3
3 3 1034.92 1 11.23 1858 21 0.27 / 1310.39 2 2
4 12 1141.52 5 4.85 1534 37 0.30 / 1310.43 2 3
5 12 1209.56 65 5.62 1986 725 1.03 / 1311.15 2 2
6 7 1217.12 24 9.04 2063 448 1.48 / 1311.60 2 2
7 13 1152.36 33 11.43 2024 763 2.24 / 1312.36 2 2
8 13 963.08 33 12.23 1771 715 2.96 / 1313.08 2 2
9 13 109.96 33 14.03 546 253 3.21 / 1313.33 2 2
10 14 -0.12 190 14.22 367 992 4.20 / 1314.32 2 11
Average= 4.92 (KJ/cycle)

Cycle 265 GMT 17/ 6/2021 17:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 33 14.20 506 237 0.24 / 1306.35 2 3
2 3 973.28 -1 14.20 506 0 0.00 / 1306.35 2 3
3 3 1022.44 1 10.85 1837 20 0.26 / 1306.37 2 2
4 12 1143.96 5 4.91 1750 43 0.30 / 1306.41 2 3
5 12 1214.08 65 6.93 2013 907 1.21 / 1307.32 2 2
6 7 1220.84 25 9.51 2091 497 1.70 / 1307.82 2 2
7 13 1099.68 34 11.77 1974 790 2.49 / 1308.61 2 2
8 13 504.20 34 13.39 1126 513 3.01 / 1309.12 2 2
9 14 0.00 190 14.23 370 1000 4.01 / 1310.12 2 4
Average= 4.93 (KJ/cycle)

Cycle 264 GMT 7/ 6/2021 22:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 33 14.12 507 236 0.24 / 1301.03 2 3
2 12 1107.56 5 10.98 1975 108 0.34 / 1301.14 2 2
3 12 2007.32 65 8.41 3196 1747 2.09 / 1302.89 2 2
4 7 2003.40 24 9.91 3219 766 2.86 / 1303.65 2 2
5 13 1371.28 33 12.43 2357 967 3.82 / 1304.62 2 2
6 13 485.00 33 13.58 1096 491 4.32 / 1305.11 2 2
7 14 0.12 190 14.26 370 1002 5.32 / 1306.11 2 11
Average= 4.93 (KJ/cycle)

Cycle 263 GMT 6/ 6/2021 18:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 33 14.16 509 238 0.24 / 1296.78 3 3
2 12 1107.76 5 4.84 1494 36 0.27 / 1296.81 2 3
3 12 1214.68 65 5.14 1977 661 0.93 / 1297.48 2 2
4 7 1222.48 25 8.89 2075 461 1.40 / 1297.94 2 2
5 13 1244.28 33 11.09 2188 801 2.20 / 1298.74 2 2
6 13 1067.96 33 12.02 1942 770 2.97 / 1299.51 2 2
7 13 189.96 33 13.90 668 306 3.27 / 1299.81 2 2
8 14 -0.08 190 14.21 364 983 4.26 / 1300.80 2 5
Average= 4.93 (KJ/cycle)

Cycle 262 GMT 27/ 5/2021 22:54: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 33 14.16 515 241 0.24 / 1292.61 2 3
2 12 1084.80 5 4.86 1582 38 0.28 / 1292.65 2 3
3 12 1207.00 65 5.64 1978 725 1.00 / 1293.38 2 2
4 7 1214.64 24 9.11 2048 448 1.45 / 1293.82 2 2
5 13 1180.56 33 11.34 2083 780 2.23 / 1294.60 2 2
6 13 980.84 33 12.24 1794 725 2.96 / 1295.33 2 2
7 13 69.76 33 14.10 477 222 3.18 / 1295.55 2 2
8 14 -0.16 190 14.21 367 991 4.17 / 1296.54 2 6
Average= 4.93 (KJ/cycle)

Cycle 261 GMT 18/ 5/2021 3:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 33 14.18 521 244 0.24 / 1288.51 3 3
2 12 1116.12 5 4.90 1744 43 0.29 / 1288.56 2 3
3 12 1201.16 65 6.84 1996 887 1.17 / 1289.44 2 2
4 7 1208.52 25 9.51 2068 492 1.67 / 1289.93 2 2
5 13 1097.36 33 11.82 1957 763 2.43 / 1290.70 2 2
6 13 487.40 33 13.42 1104 489 2.92 / 1291.19 2 2
7 13 16.88 33 14.19 395 185 3.10 / 1291.37 2 2
8 14 -0.12 190 14.18 371 1000 4.10 / 1292.37 2 7
Average= 4.93 (KJ/cycle)

Cycle 260 GMT 8/ 5/2021 8: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 33 14.16 510 238 0.24 / 1282.95 3 3
2 3 971.00 -1 14.16 510 0 0.00 / 1282.95 3 3
3 3 1042.24 1 11.10 1861 21 0.26 / 1282.97 2 2
4 12 1144.08 5 11.07 1996 110 0.37 / 1283.08 2 2
5 12 2003.80 65 8.53 3197 1773 2.14 / 1284.85 2 2
6 7 1999.64 24 9.92 3216 766 2.91 / 1285.62 2 2
7 13 1563.96 33 12.22 2628 1060 3.97 / 1286.68 2 2
8 13 624.92 33 13.40 1309 579 4.55 / 1287.26 2 2
9 14 -0.12 190 14.26 373 1011 5.56 / 1288.27 2 3
Average= 4.94 (KJ/cycle)

Cycle 259 GMT 7/ 5/2021 5: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 33 14.18 510 239 0.24 / 1278.75 3 3
2 12 1104.20 5 4.83 1467 35 0.27 / 1278.78 2 3
3 12 1198.68 65 5.29 1958 673 0.95 / 1279.46 2 2
4 7 1206.44 24 9.08 2058 448 1.40 / 1279.90 2 2
5 13 1202.92 33 11.40 2127 800 2.20 / 1280.70 2 2
6 13 1009.16 33 12.29 1845 748 2.94 / 1281.45 2 2
7 13 159.08 33 13.96 611 281 3.23 / 1281.73 2 2
8 14 0.00 190 14.22 362 978 4.20 / 1282.71 2 5
Average= 4.93 (KJ/cycle)

Cycle 258 GMT 27/ 4/2021 9:34: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 33 14.18 508 238 0.24 / 1274.39 3 3
2 12 1118.04 5 4.83 1480 36 0.27 / 1274.43 2 3
3 12 1213.68 65 5.30 1988 685 0.96 / 1275.12 2 2
4 7 1220.76 24 9.10 2063 451 1.41 / 1275.57 2 2
5 13 1269.48 34 11.25 2204 843 2.25 / 1276.41 2 2
6 13 1086.60 34 12.14 1961 809 3.06 / 1277.22 2 2
7 13 161.88 34 13.96 624 296 3.36 / 1277.51 2 2
8 14 -0.16 190 14.22 368 994 4.35 / 1278.51 2 6
Average= 4.94 (KJ/cycle)

Cycle 257 GMT 17/ 4/2021 13:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 33 14.22 509 239 0.24 / 1270.13 3 3
2 12 1104.32 5 4.89 1721 42 0.28 / 1270.17 2 3
3 12 1204.60 65 7.03 2001 914 1.20 / 1271.08 2 2
4 7 1209.96 25 9.70 2069 502 1.70 / 1271.59 2 2
5 13 1107.32 33 11.95 1983 782 2.48 / 1272.37 2 2
6 13 691.56 33 13.12 1397 605 3.08 / 1272.97 2 2
7 13 31.32 33 14.16 419 196 3.28 / 1273.17 2 2
8 14 -0.08 190 14.22 366 989 4.27 / 1274.16 2 15
Average= 4.94 (KJ/cycle)

Cycle 256 GMT 7/ 4/2021 18:40: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 33 14.18 509 238 0.24 / 1264.73 3 3
2 12 1108.20 5 11.02 1934 107 0.34 / 1264.83 2 2
3 12 2005.88 65 8.82 3200 1835 2.18 / 1266.67 2 2
4 7 2001.32 25 10.07 3221 811 2.99 / 1267.48 2 2
5 13 1341.52 33 12.59 2314 961 3.95 / 1268.44 2 2
6 13 461.32 33 13.66 1056 476 4.43 / 1268.92 2 2
7 14 -0.08 190 14.29 358 972 5.40 / 1269.89 2 5
Average= 4.94 (KJ/cycle)

Cycle 255 GMT 6/ 4/2021 15:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 33 14.17 511 239 0.24 / 1259.74 3 3
2 12 1122.04 5 4.81 1410 34 0.27 / 1259.78 2 3
3 12 1215.96 65 4.87 1973 625 0.90 / 1260.40 2 3
4 7 1225.12 24 9.15 2078 456 1.35 / 1260.86 3 2
5 13 1357.72 34 11.09 2310 871 2.22 / 1261.73 2 2
6 13 1231.32 34 11.94 2143 870 3.09 / 1262.60 2 2
7 13 804.16 34 13.01 1554 687 3.78 / 1263.29 2 2
8 13 53.92 34 14.13 456 219 4.00 / 1263.51 2 2
9 14 0.00 190 14.22 364 983 4.98 / 1264.49 2 11
Average= 4.94 (KJ/cycle)

Cycle 254 GMT 27/ 3/2021 19:17: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 33 14.16 503 235 0.24 / 1255.53 3 3
2 12 1117.92 5 4.83 1478 36 0.27 / 1255.56 2 3
3 12 1202.28 65 5.56 1971 712 0.98 / 1256.28 2 2
4 7 1209.88 25 9.35 2048 479 1.46 / 1256.75 2 2
5 13 1155.12 33 11.68 2051 791 2.25 / 1257.55 2 2
6 13 956.64 33 12.50 1769 730 2.98 / 1258.27 2 2
7 13 105.28 33 14.04 529 245 3.23 / 1258.52 2 2
8 14 -0.08 191 14.23 362 984 4.21 / 1259.50 2 6
Average= 4.94 (KJ/cycle)

Cycle 253 GMT 18/ 3/2021 0: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 33 14.20 517 242 0.24 / 1251.37 3 3
2 12 1127.08 5 4.90 1760 43 0.29 / 1251.42 2 3
3 12 1203.20 65 7.34 2008 958 1.24 / 1252.37 2 2
4 7 1209.28 24 9.93 2059 491 1.73 / 1252.86 2 2
5 13 1079.36 33 12.12 1948 779 2.51 / 1253.64 2 2
6 13 460.68 33 13.53 1059 473 2.99 / 1254.12 2 2
7 13 16.16 33 14.20 393 184 3.17 / 1254.30 2 3
8 14 -0.04 190 14.20 368 993 4.16 / 1255.29 2 5
Average= 4.94 (KJ/cycle)

Cycle 252 GMT 8/ 3/2021 4:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 33 14.21 508 238 0.24 / 1246.12 3 3
2 12 1105.08 5 11.06 1934 107 0.35 / 1246.22 2 2
3 12 2000.40 65 8.87 3200 1845 2.19 / 1248.07 2 2
4 7 1996.08 25 10.12 3228 817 3.01 / 1248.89 2 2
5 13 1173.92 33 12.80 2066 873 3.88 / 1249.76 2 2
6 13 314.48 33 13.83 847 387 4.27 / 1250.15 2 2
7 14 -0.08 190 14.27 363 984 5.25 / 1251.13 2 7
Average= 4.95 (KJ/cycle)

Cycle 251 GMT 7/ 3/2021 1: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 33 14.14 501 234 0.23 / 1241.32 3 3
2 12 1111.60 5 4.82 1424 34 0.27 / 1241.35 2 3
3 12 1206.44 65 4.91 1996 637 0.91 / 1241.99 2 2
4 7 1216.52 24 9.19 2069 456 1.36 / 1242.44 2 2
5 13 1344.80 33 11.32 2292 856 2.22 / 1243.30 2 2
6 13 1202.92 33 12.10 2117 845 3.06 / 1244.15 2 2
7 13 596.16 33 13.35 1267 558 3.62 / 1244.70 2 2
8 13 28.76 33 14.17 410 192 3.81 / 1244.90 2 2
9 14 -0.20 190 14.23 364 984 4.80 / 1245.88 2 14
Average= 4.94 (KJ/cycle)

Cycle 250 GMT 25/ 2/2021 4:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 33 14.16 501 234 0.23 / 1236.70 3 3
2 12 1119.92 5 4.83 1445 35 0.27 / 1236.73 2 3
3 12 1218.92 65 5.22 2009 682 0.95 / 1237.41 2 2
4 7 1227.88 25 9.28 2075 481 1.43 / 1237.89 2 2
5 13 1305.88 34 11.40 2249 872 2.30 / 1238.77 2 2
6 13 1131.64 34 12.24 2016 839 3.14 / 1239.61 2 2
7 13 453.84 34 13.55 1056 486 3.63 / 1240.09 2 2
8 14 -0.08 190 14.21 367 991 4.62 / 1241.08 2 5
Average= 4.94 (KJ/cycle)

Cycle 249 GMT 15/ 2/2021 9:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 33 14.17 504 236 0.24 / 1232.78 3 3
2 12 1118.60 5 4.89 1696 41 0.28 / 1232.82 2 3
3 12 1204.92 65 7.12 2002 927 1.20 / 1233.75 2 2
4 7 1211.44 24 9.90 2057 489 1.69 / 1234.24 2 2
5 13 1082.68 33 12.13 1937 775 2.47 / 1235.01 2 2
6 13 469.92 33 13.51 1072 478 2.95 / 1235.49 2 2
7 14 -0.12 190 14.22 360 973 3.92 / 1236.46 2 4
Average= 4.95 (KJ/cycle)

Cycle 248 GMT 5/ 2/2021 14: 2: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 33 14.14 502 234 0.23 / 1227.34 3 3
2 12 1119.32 5 10.94 1956 107 0.34 / 1227.44 2 2
3 12 2002.16 66 8.82 3197 1861 2.20 / 1229.30 2 2
4 7 1997.56 24 10.14 3233 787 2.99 / 1230.09 2 2
5 13 1338.20 34 12.62 2298 986 3.98 / 1231.08 2 2
6 13 437.40 34 13.68 1028 478 4.45 / 1231.55 2 2
7 14 -0.12 190 14.27 365 990 5.44 / 1232.54 2 6
Average= 4.95 (KJ/cycle)

Cycle 247 GMT 4/ 2/2021 10:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 33 14.15 511 239 0.24 / 1222.73 2 3
2 12 1119.48 5 4.83 1441 35 0.27 / 1222.76 2 3
3 12 1201.24 66 5.23 1983 684 0.96 / 1223.45 2 2
4 7 1209.32 24 9.45 2052 465 1.42 / 1223.91 2 2
5 13 1303.08 34 11.47 2250 877 2.30 / 1224.79 2 2
6 13 1135.28 34 12.30 2018 844 3.14 / 1225.64 2 2
7 13 459.88 34 13.54 1060 488 3.63 / 1226.12 2 2
8 14 0.00 190 14.22 362 978 4.61 / 1227.10 2 8
Average= 4.95 (KJ/cycle)

Cycle 246 GMT 25/ 1/2021 15: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 33 14.15 515 240 0.24 / 1218.54 3 3
2 12 1115.32 5 4.84 1502 36 0.28 / 1218.57 2 3
3 12 1204.44 65 5.88 1973 754 1.03 / 1219.33 2 2
4 7 1212.32 24 9.57 2055 472 1.50 / 1219.80 2 2
5 13 1150.36 34 11.84 2050 825 2.33 / 1220.62 2 2
6 13 767.80 34 12.98 1508 666 2.99 / 1221.29 2 2
7 13 51.56 34 14.12 444 213 3.21 / 1221.50 2 2
8 14 -0.04 190 14.20 366 987 4.19 / 1222.49 2 11
Average= 4.95 (KJ/cycle)

Cycle 245 GMT 15/ 1/2021 19:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 33 14.18 501 234 0.23 / 1214.43 3 3
2 12 1117.48 5 4.90 1747 43 0.28 / 1214.47 2 3
3 12 1219.28 65 7.23 2032 955 1.23 / 1215.43 2 2
4 7 1226.28 25 9.91 2128 527 1.76 / 1215.96 2 2
5 13 1082.44 33 12.20 1965 791 2.55 / 1216.75 2 2
6 13 289.28 33 13.76 816 371 2.92 / 1217.12 2 2
7 13 25.96 33 14.17 405 189 3.11 / 1217.31 2 3
8 14 0.00 190 14.21 366 988 4.10 / 1218.30 2 4
Average= 4.95 (KJ/cycle)

Cycle 244 GMT 6/ 1/2021 0:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 33 14.11 523 244 0.24 / 1208.94 3 3
2 12 1117.48 5 10.99 1961 108 0.35 / 1209.05 2 2
3 12 2004.48 65 8.81 3187 1825 2.18 / 1210.87 2 2
4 7 2001.12 24 10.21 3232 792 2.97 / 1211.66 2 2
5 13 1384.36 34 12.57 2362 1009 3.98 / 1212.67 2 2
6 13 501.16 34 13.60 1127 521 4.50 / 1213.19 2 2
7 14 -0.12 190 14.23 371 1003 5.50 / 1214.20 2 4
Average= 4.96 (KJ/cycle)

Cycle 243 GMT 4/ 1/2021 20:34: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 33 14.12 516 240 0.24 / 1204.76 2 3
2 12 1117.44 5 4.85 1532 37 0.28 / 1204.79 2 3
3 12 1207.08 65 5.93 1984 765 1.04 / 1205.56 2 2
4 7 1215.32 24 9.61 2081 480 1.52 / 1206.04 2 2
5 13 1141.40 33 11.94 2053 809 2.33 / 1206.85 2 2
6 13 760.00 33 13.02 1501 645 2.98 / 1207.49 2 2
7 13 30.60 33 14.13 420 196 3.17 / 1207.69 2 2
8 14 -0.16 190 14.17 374 1007 4.18 / 1208.70 2 9
Average= 4.95 (KJ/cycle)

Cycle 242 GMT 26/12/2020 1: 7:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 33 14.14 510 238 0.24 / 1200.38 2 3
2 12 1115.48 5 4.83 1473 36 0.27 / 1200.41 2 3
3 12 1219.16 65 5.63 2022 740 1.01 / 1201.15 2 2
4 7 1227.92 24 9.55 2098 481 1.49 / 1201.63 2 2
5 13 1231.72 34 11.76 2170 868 2.36 / 1202.50 2 2
6 13 1033.20 34 12.54 1880 802 3.16 / 1203.30 2 2
7 13 39.32 34 14.12 436 209 3.37 / 1203.51 2 2
8 14 -0.16 190 14.17 374 1007 4.38 / 1204.52 2 6
Average= 4.96 (KJ/cycle)

Cycle 241 GMT 16/12/2020 5:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 33 14.15 523 244 0.24 / 1196.39 2 3
2 12 1123.08 5 4.91 1784 44 0.29 / 1196.44 2 3
3 12 1205.56 65 7.59 2012 993 1.28 / 1197.43 2 2
4 7 1210.96 24 10.16 2067 504 1.78 / 1197.93 2 2
5 13 1054.60 33 12.32 1907 775 2.56 / 1198.71 2 2
6 13 400.80 33 13.60 984 442 3.00 / 1199.15 2 2
7 14 -0.08 190 14.20 366 987 3.99 / 1200.14 2 3
Average= 4.96 (KJ/cycle)

Cycle 240 GMT 6/12/2020 10:19:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 33 14.13 513 239 0.24 / 1190.96 2 3
2 12 1116.28 5 10.89 1966 107 0.35 / 1191.06 2 2
3 12 2000.52 65 8.91 3198 1852 2.20 / 1192.92 2 2
4 7 1996.08 24 10.20 3226 790 2.99 / 1193.71 2 2
5 13 1184.20 34 12.80 2099 913 3.90 / 1194.62 2 2
6 13 511.64 34 13.57 1151 531 4.43 / 1195.15 2 2
7 14 0.00 190 14.24 369 998 5.43 / 1196.15 2 8
Average= 4.96 (KJ/cycle)

Cycle 239 GMT 5/12/2020 6:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 33 14.12 508 237 0.24 / 1186.72 2 3
2 12 1100.72 5 4.85 1540 37 0.27 / 1186.76 2 3
3 12 1215.08 65 5.88 1996 763 1.04 / 1187.52 2 2
4 7 1222.36 25 9.65 2088 504 1.54 / 1188.03 2 2
5 13 1136.72 34 12.01 2032 830 2.37 / 1188.86 2 2
6 13 755.92 34 13.04 1494 662 3.03 / 1189.52 2 2
7 13 23.60 34 14.15 412 198 3.23 / 1189.72 2 2
8 14 0.04 190 14.19 371 1000 4.23 / 1190.72 2 9
Average= 4.96 (KJ/cycle)

Cycle 238 GMT 25/11/2020 11:29: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 33 14.08 523 243 0.24 / 1182.39 3 3
2 12 1129.60 5 4.84 1518 37 0.28 / 1182.43 2 3
3 12 1213.96 65 6.06 1999 787 1.07 / 1183.22 2 2
4 7 1221.20 25 9.71 2089 507 1.57 / 1183.72 2 2
5 13 1126.40 34 12.08 2011 826 2.40 / 1184.55 2 2
6 13 934.08 34 12.72 1741 753 3.15 / 1185.30 2 2
7 13 14.88 34 14.17 388 187 3.34 / 1185.49 2 2
8 14 -0.08 190 14.17 370 996 4.34 / 1186.49 2 12
Average= 4.96 (KJ/cycle)

Cycle 237 GMT 15/11/2020 16:22:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 33 14.14 514 240 0.24 / 1178.29 3 3
2 12 1121.12 5 4.90 1747 43 0.28 / 1178.33 2 3
3 12 1219.40 65 7.59 2035 1004 1.29 / 1179.34 2 2
4 7 1225.52 24 10.27 2091 515 1.80 / 1179.85 2 2
5 13 1084.84 34 12.37 1935 814 2.62 / 1180.67 2 2
6 13 457.08 34 13.54 1050 483 3.10 / 1181.15 2 2
7 14 -0.16 190 14.18 371 1000 4.10 / 1182.15 2 7
Average= 4.97 (KJ/cycle)

Cycle 236 GMT 5/11/2020 21: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 33 14.13 508 237 0.24 / 1172.78 3 3
2 12 1134.56 5 10.95 2003 110 0.35 / 1172.89 2 2
3 12 2002.56 65 9.01 3224 1888 2.23 / 1174.78 2 2
4 7 1998.48 25 10.22 3240 828 3.06 / 1175.61 2 2
5 13 1321.20 34 12.68 2286 986 4.05 / 1176.59 2 2
6 13 408.52 34 13.71 997 465 4.51 / 1177.06 2 2
7 14 -0.08 190 14.26 367 994 5.51 / 1178.05 2 5
Average= 4.97 (KJ/cycle)

Cycle 235 GMT 4/11/2020 18: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 33 14.13 512 239 0.24 / 1168.64 3 3
2 12 1139.16 5 4.85 1518 37 0.28 / 1168.67 2 3
3 12 1202.32 65 6.10 1983 786 1.06 / 1169.46 2 2
4 7 1209.60 24 9.79 2060 484 1.55 / 1169.94 2 2
5 13 1134.12 33 12.14 1998 800 2.35 / 1170.74 2 2
6 13 740.52 33 13.09 1476 638 2.98 / 1171.38 2 2
7 13 24.16 33 14.17 400 187 3.17 / 1171.57 2 3
8 14 0.16 190 14.22 361 975 4.15 / 1172.54 2 9
Average= 4.97 (KJ/cycle)

Cycle 234 GMT 25/10/2020 22:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 33 14.12 515 240 0.24 / 1164.42 3 3
2 12 1135.76 5 4.86 1563 38 0.28 / 1164.45 2 3
3 12 1202.32 65 6.50 1989 840 1.12 / 1165.29 2 2
4 7 1209.80 24 10.02 2062 496 1.61 / 1165.79 2 2
5 13 1104.16 34 12.14 1990 821 2.44 / 1166.61 2 2
6 13 696.36 34 13.12 1418 633 3.07 / 1167.24 2 2
7 13 17.88 34 14.19 386 186 3.25 / 1167.43 2 2
8 14 -0.12 190 14.22 358 967 4.22 / 1168.40 3 7
Average= 4.97 (KJ/cycle)

Cycle 233 GMT 16/10/2020 3:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 33 14.13 514 240 0.24 / 1160.44 3 3
2 12 1136.36 5 4.93 1858 46 0.29 / 1160.48 2 3
3 12 1204.72 65 8.06 2024 1060 1.35 / 1161.54 2 2
4 7 1209.88 25 10.32 2087 538 1.88 / 1162.08 2 2
5 13 1038.20 34 12.44 1886 798 2.68 / 1162.88 2 2
6 13 194.36 34 13.91 663 314 3.00 / 1163.19 2 2
7 14 -0.04 190 14.22 364 983 3.98 / 1164.18 2 5
Average= 4.98 (KJ/cycle)

Cycle 232 GMT 6/10/2020 8:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 33 14.11 509 237 0.24 / 1155.09 2 3
2 12 1114.20 5 10.99 1984 109 0.35 / 1155.19 2 2
3 12 2001.28 65 9.12 3203 1899 2.24 / 1157.09 2 2
4 7 1995.68 24 10.26 3224 794 3.04 / 1157.89 2 2
5 13 1333.08 34 12.67 2295 989 4.03 / 1158.88 2 2
6 13 219.20 34 13.93 704 333 4.36 / 1159.21 2 2
7 14 -0.16 190 14.28 364 988 5.35 / 1160.20 2 8
Average= 4.98 (KJ/cycle)

Cycle 231 GMT 5/10/2020 5: 0: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 32 14.11 512 231 0.23 / 1150.81 3 3
2 12 1137.16 5 4.85 1538 37 0.27 / 1150.85 2 3
3 12 1215.72 65 6.41 1999 833 1.10 / 1151.68 2 2
4 7 1221.92 24 10.02 2075 499 1.60 / 1152.18 2 2
5 13 1135.56 34 12.20 2020 838 2.44 / 1153.02 2 2
6 13 730.60 34 13.13 1449 647 3.09 / 1153.67 2 2
7 13 46.20 34 14.15 431 207 3.29 / 1153.88 2 2
8 14 0.16 190 14.23 360 973 4.27 / 1154.85 2 7
Average= 4.98 (KJ/cycle)

Cycle 230 GMT 25/ 9/2020 9:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 32 14.09 519 234 0.23 / 1146.70 3 3
2 12 1120.80 5 4.87 1628 40 0.27 / 1146.74 2 3
3 12 1218.72 66 6.79 2015 903 1.18 / 1147.64 2 2
4 7 1226.04 24 10.06 2118 511 1.69 / 1148.15 2 2
5 13 1105.96 34 12.27 1978 825 2.51 / 1148.98 2 2
6 13 690.28 34 13.18 1391 623 3.14 / 1149.60 2 2
7 14 -0.08 190 14.23 363 981 4.12 / 1150.58 2 3
Average= 4.98 (KJ/cycle)

Cycle 229 GMT 15/ 9/2020 14:37: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 33 14.14 509 238 0.24 / 1142.58 3 3
2 12 1103.76 5 4.95 1953 48 0.29 / 1142.63 2 3
3 12 1209.84 65 8.28 2049 1103 1.39 / 1143.73 2 2
4 7 1215.08 24 10.36 2128 529 1.92 / 1144.26 2 2
5 13 1042.20 33 12.49 1898 782 2.70 / 1145.04 2 2
6 13 375.48 33 13.64 937 422 3.12 / 1145.46 2 2
7 14 0.00 190 14.17 372 1002 4.12 / 1146.46 2 9
Average= 4.98 (KJ/cycle)

Cycle 228 GMT 5/ 9/2020 19:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 33 14.10 516 240 0.24 / 1137.31 3 3
2 12 1105.16 5 11.10 1983 110 0.35 / 1137.42 2 2
3 12 2009.00 65 9.16 3226 1921 2.27 / 1139.34 2 2
4 7 2004.76 24 10.26 3243 799 3.07 / 1140.13 2 2
5 13 1143.92 33 12.85 2048 868 3.94 / 1141.00 2 2
6 13 255.84 33 13.86 771 353 4.29 / 1141.36 2 2
7 14 -0.04 190 14.25 364 986 5.28 / 1142.34 2 11
Average= 4.99 (KJ/cycle)

Cycle 227 GMT 4/ 9/2020 15:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 32 14.10 516 233 0.23 / 1133.18 3 3
2 12 1127.00 5 4.87 1623 40 0.27 / 1133.22 2 3
3 12 1218.04 66 6.67 2021 890 1.16 / 1134.11 2 2
4 7 1224.00 24 10.05 2138 516 1.68 / 1134.63 2 2
5 13 1094.88 34 12.27 1973 823 2.50 / 1135.45 2 2
6 13 684.04 34 13.18 1386 621 3.12 / 1136.07 2 2
7 14 -0.12 190 14.19 368 992 4.11 / 1137.07 2 5
Average= 4.99 (KJ/cycle)

Cycle 226 GMT 25/ 8/2020 20:39: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 33 14.12 506 236 0.24 / 1129.20 2 3
2 3 968.92 -1 14.12 506 0 0.00 / 1129.20 2 3
3 3 1033.60 1 11.25 1851 21 0.26 / 1129.22 2 2
4 12 1144.44 5 4.87 1613 39 0.30 / 1129.26 2 3
5 12 1204.88 65 7.16 2010 935 1.23 / 1130.20 2 2
6 7 1211.48 24 10.17 2085 509 1.74 / 1130.71 2 2
7 13 1067.20 33 12.38 1922 785 2.53 / 1131.49 2 2
8 13 447.72 33 13.52 1042 465 2.99 / 1131.96 2 2
9 14 -0.04 190 14.20 368 993 3.98 / 1132.95 2 6
Average= 4.99 (KJ/cycle)

Cycle 225 GMT 16/ 8/2020 1:39: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 33 14.15 511 239 0.24 / 1125.10 3 3
2 3 967.64 -1 14.15 511 0 0.00 / 1125.10 3 3
3 3 1036.76 1 11.66 1879 22 0.26 / 1125.13 2 2
4 12 1149.48 5 4.95 1946 48 0.31 / 1125.17 2 3
5 12 1216.80 66 8.57 2047 1158 1.47 / 1126.33 2 2
6 7 1220.36 24 10.48 2100 528 1.99 / 1126.86 2 2
7 13 1042.96 34 12.56 1885 805 2.80 / 1127.66 2 2
8 13 184.64 34 13.89 659 311 3.11 / 1127.98 2 2
9 14 0.20 190 14.19 368 992 4.10 / 1128.97 2 11
Average= 5.00 (KJ/cycle)

Cycle 224 GMT 6/ 8/2020 6:29: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 33 14.11 502 234 0.23 / 1119.75 3 3
2 3 967.20 -1 14.11 502 0 0.00 / 1119.75 3 3
3 3 1032.68 1 11.16 1856 21 0.25 / 1119.77 2 2
4 12 1140.16 5 11.16 2018 113 0.37 / 1119.89 2 2
5 12 2002.16 65 9.31 3217 1947 2.31 / 1121.83 2 2
6 7 1997.68 24 10.26 3233 796 3.11 / 1122.63 2 2
7 13 1136.88 33 12.85 2039 865 3.97 / 1123.49 2 2
8 13 246.80 33 13.86 766 350 4.32 / 1123.84 2 2
9 14 -0.08 190 14.24 377 1020 5.34 / 1124.86 2 9
Average= 5.00 (KJ/cycle)

Cycle 223 GMT 5/ 8/2020 2:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 33 14.08 516 240 0.24 / 1115.78 2 3
2 12 1114.80 5 4.88 1643 40 0.28 / 1115.82 2 3
3 12 1201.92 65 6.90 1998 896 1.18 / 1116.72 2 2
4 7 1207.60 24 10.16 2113 515 1.69 / 1117.23 2 2
5 13 1082.88 34 12.31 1959 820 2.51 / 1118.05 2 2
6 13 479.88 34 13.48 1087 498 3.01 / 1118.55 2 2
7 14 0.08 190 14.20 360 971 3.98 / 1119.52 2 3
Average= 5.00 (KJ/cycle)

Cycle 222 GMT 26/ 7/2020 7:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 33 14.13 509 237 0.24 / 1111.78 3 3
2 12 1105.68 5 4.89 1692 41 0.28 / 1111.82 2 3
3 12 1207.84 65 7.36 2014 963 1.24 / 1112.78 2 2
4 7 1214.96 24 10.27 2089 515 1.76 / 1113.30 2 2
5 13 1071.40 33 12.38 1930 788 2.55 / 1114.09 2 2
6 13 432.64 33 13.53 1021 456 3.00 / 1114.54 2 2
7 14 -0.20 190 14.15 371 997 4.00 / 1115.54 2 4
Average= 5.00 (KJ/cycle)

Cycle 221 GMT 16/ 7/2020 12:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 33 14.16 518 242 0.24 / 1107.76 3 3
2 12 1103.76 5 4.95 1933 48 0.29 / 1107.81 2 3
3 12 1205.12 65 8.50 2048 1132 1.42 / 1108.94 2 2
4 7 1209.32 24 10.49 2112 532 1.95 / 1109.48 2 2
5 13 1033.96 33 12.57 1876 778 2.73 / 1110.25 2 2
6 13 190.24 33 13.90 669 307 3.04 / 1110.56 2 2
7 14 -0.08 190 14.21 363 980 4.02 / 1111.54 2 6
Average= 5.01 (KJ/cycle)

Cycle 220 GMT 6/ 7/2020 17:19:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 33 14.11 500 233 0.23 / 1102.27 2 3
2 12 1114.52 5 11.14 1950 109 0.34 / 1102.38 2 2
3 12 2000.12 65 9.30 3205 1937 2.28 / 1104.31 2 2
4 7 1995.76 25 10.32 3224 832 3.11 / 1105.15 2 2
5 13 1318.64 33 12.69 2278 954 4.06 / 1106.10 2 2
6 13 395.08 33 13.72 964 436 4.50 / 1106.54 2 2
7 14 0.08 190 14.29 363 986 5.49 / 1107.52 2 4
Average= 5.01 (KJ/cycle)

Cycle 219 GMT 5/ 7/2020 13:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 33 14.11 511 238 0.24 / 1098.28 3 3
2 3 967.28 -1 14.11 511 0 0.00 / 1098.28 3 3
3 3 1032.84 1 11.22 1854 21 0.26 / 1098.30 2 2
4 12 1150.36 5 4.86 1581 38 0.30 / 1098.34 2 3
5 12 1204.20 65 7.04 2005 917 1.21 / 1099.25 2 2
6 7 1210.96 24 10.24 2088 513 1.73 / 1099.77 2 2
7 13 1076.12 34 12.39 1950 821 2.55 / 1100.59 2 2
8 13 441.76 34 13.54 1035 476 3.03 / 1101.07 2 2
9 14 -0.04 190 14.23 359 971 4.00 / 1102.04 2 5
Average= 5.01 (KJ/cycle)

Cycle 218 GMT 25/ 6/2020 19: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 33 14.08 511 237 0.24 / 1094.24 3 3
2 12 1123.84 5 4.87 1609 39 0.28 / 1094.28 2 3
3 12 1207.00 65 7.53 2011 984 1.26 / 1095.26 2 2
4 7 1213.60 25 10.39 2082 541 1.80 / 1095.80 2 2
5 13 1081.40 33 12.43 1945 798 2.60 / 1096.60 2 2
6 13 448.08 33 13.54 1033 462 3.06 / 1097.06 2 2
7 14 0.08 190 14.23 362 979 4.04 / 1098.04 2 6
Average= 5.01 (KJ/cycle)

Cycle 217 GMT 15/ 6/2020 23:59: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 32 14.18 519 236 0.24 / 1090.15 3 3
2 3 1021.24 1 11.81 1855 22 0.26 / 1090.17 2 2
3 3 1019.12 1 11.25 1857 21 0.28 / 1090.19 2 2
4 12 1146.08 5 4.96 1965 49 0.33 / 1090.24 2 3
5 12 1203.24 65 8.79 2046 1169 1.50 / 1091.41 2 2
6 7 1208.16 25 10.57 2118 560 2.06 / 1091.97 2 2
7 13 1022.68 33 12.62 1865 777 2.83 / 1092.75 2 2
8 13 160.20 33 13.97 607 280 3.11 / 1093.03 2 3
9 14 -0.08 190 14.25 359 972 4.08 / 1094.00 2 7
Average= 5.02 (KJ/cycle)

Cycle 216 GMT 6/ 6/2020 4:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 32 14.11 514 232 0.23 / 1084.82 3 3
2 3 1037.24 1 11.59 1861 22 0.25 / 1084.84 2 2
3 3 1020.36 1 10.94 1843 20 0.27 / 1084.86 2 2
4 12 1138.04 5 11.34 2007 114 0.39 / 1084.97 2 2
5 12 2002.48 65 9.40 3207 1959 2.35 / 1086.93 2 2
6 7 1998.00 24 10.30 3238 800 3.15 / 1087.73 2 2
7 13 1140.60 33 12.86 2035 864 4.01 / 1088.59 2 2
8 13 255.24 33 13.90 758 348 4.36 / 1088.94 2 2
9 14 0.04 191 14.31 356 973 5.33 / 1089.92 2 9
Average= 5.02 (KJ/cycle)

Cycle 215 GMT 5/ 6/2020 1:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 32 14.10 510 230 0.23 / 1080.84 3 3
2 12 1149.72 5 4.88 1668 41 0.27 / 1080.88 2 3
3 12 1208.24 65 7.48 2021 983 1.25 / 1081.86 2 2
4 7 1214.96 24 10.33 2112 524 1.78 / 1082.38 2 2
5 13 1069.88 33 12.42 1940 795 2.57 / 1083.18 2 2
6 13 418.44 33 13.58 991 444 3.02 / 1083.62 2 2
7 14 -0.12 190 14.25 355 961 3.98 / 1084.58 2 7
Average= 5.02 (KJ/cycle)

Cycle 214 GMT 26/ 5/2020 6:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 32 14.13 509 230 0.23 / 1076.92 3 3
2 12 1140.08 5 4.90 1754 43 0.27 / 1076.96 2 3
3 12 1211.32 65 7.97 2030 1052 1.32 / 1078.01 2 2
4 7 1218.00 24 10.45 2099 526 1.85 / 1078.54 2 2
5 13 1054.20 33 12.47 1913 787 2.64 / 1079.32 2 2
6 13 202.64 33 13.87 675 309 2.95 / 1079.63 2 2
7 14 -0.04 190 14.22 360 973 3.92 / 1080.61 2 8
Average= 5.03 (KJ/cycle)

Cycle 213 GMT 16/ 5/2020 11:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 32 14.17 509 231 0.23 / 1072.92 3 3
2 12 1129.08 5 4.98 2095 52 0.28 / 1072.97 2 3
3 12 1208.40 65 9.23 2045 1227 1.51 / 1074.19 2 2
4 7 1211.72 25 10.66 2097 559 2.07 / 1074.75 2 3
5 13 840.16 34 12.92 1611 708 2.78 / 1075.46 2 2
6 13 97.56 34 14.06 519 248 3.02 / 1075.71 2 3
7 14 0.00 190 14.24 361 977 4.00 / 1076.69 3 6
Average= 5.03 (KJ/cycle)

Cycle 212 GMT 6/ 5/2020 16:18: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 32 14.14 488 221 0.22 / 1067.47 3 3
2 12 1122.56 5 11.42 1969 112 0.33 / 1067.59 2 2
3 12 2003.80 65 9.47 3211 1977 2.31 / 1069.56 2 2
4 7 1999.16 24 10.30 3229 798 3.11 / 1070.36 2 2
5 13 1110.28 33 12.88 1995 848 3.96 / 1071.21 2 3
6 13 218.44 33 13.93 703 323 4.28 / 1071.53 2 2
7 13 4.20 33 14.28 371 175 4.45 / 1071.71 2 3
8 14 -0.08 190 14.30 360 978 5.43 / 1072.68 2 10
Average= 5.04 (KJ/cycle)

Cycle 211 GMT 5/ 5/2020 12:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 32 14.16 491 222 0.22 / 1063.59 3 3
2 12 1130.76 5 4.89 1702 42 0.26 / 1063.63 2 3
3 12 1208.56 65 7.73 2020 1015 1.28 / 1064.64 2 2
4 7 1213.08 24 10.48 2076 522 1.80 / 1065.16 2 2
5 13 1066.60 33 12.46 1939 797 2.60 / 1065.96 2 2
6 13 217.20 33 13.85 700 320 2.92 / 1066.28 2 2
7 14 -0.08 190 14.23 359 971 3.89 / 1067.25 2 10
Average= 5.03 (KJ/cycle)

Cycle 210 GMT 25/ 4/2020 17:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 32 14.14 510 231 0.23 / 1059.65 3 3
2 12 1146.44 5 4.91 1791 44 0.27 / 1059.69 2 3
3 12 1204.20 65 8.18 2020 1074 1.35 / 1060.77 2 2
4 7 1210.04 24 10.53 2082 526 1.87 / 1061.29 2 2
5 13 1042.08 33 12.50 1910 788 2.66 / 1062.08 2 2
6 13 192.52 33 13.89 661 303 2.97 / 1062.39 2 2
7 14 0.00 190 14.22 362 978 3.94 / 1063.36 3 6
Average= 5.04 (KJ/cycle)

Cycle 209 GMT 15/ 4/2020 22:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 32 14.20 488 222 0.22 / 1055.56 3 3
2 12 1121.40 5 5.02 2247 56 0.28 / 1055.62 2 3
3 12 1209.32 65 9.50 2050 1266 1.54 / 1056.89 2 2
4 7 1213.20 25 10.65 2119 564 2.11 / 1057.45 2 2
5 13 1014.88 33 12.63 1862 776 2.88 / 1058.23 2 2
6 13 75.68 33 14.11 472 220 3.10 / 1058.45 2 3
7 14 -0.04 190 14.24 360 974 4.08 / 1059.42 2 6
Average= 5.04 (KJ/cycle)

Cycle 208 GMT 6/ 4/2020 3:33: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 32 14.13 515 233 0.23 / 1050.29 3 3
2 12 1107.96 5 11.45 1986 114 0.35 / 1050.41 2 2
3 12 2006.60 65 9.45 3223 1980 2.33 / 1052.39 2 2
4 7 2001.96 24 10.31 3236 801 3.13 / 1053.19 2 2
5 13 1114.32 33 12.89 1992 847 3.97 / 1054.03 2 3
6 13 220.20 33 13.92 709 326 4.30 / 1054.36 2 2
7 14 -0.04 190 14.28 362 982 5.28 / 1055.34 2 9
Average= 5.05 (KJ/cycle)

Cycle 207 GMT 5/ 4/2020 0: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 32 14.14 506 229 0.23 / 1046.19 3 3
2 12 1118.68 5 4.91 1782 44 0.27 / 1046.23 2 3
3 12 1211.40 65 7.75 2040 1028 1.30 / 1047.26 2 2
4 7 1216.36 25 10.42 2134 556 1.86 / 1047.81 2 2
5 13 1058.56 34 12.43 1942 821 2.68 / 1048.63 2 2
6 13 398.04 34 13.56 977 450 3.13 / 1049.08 2 3
7 14 -0.12 190 14.22 361 975 4.10 / 1050.06 2 8
Average= 5.05 (KJ/cycle)

Cycle 206 GMT 26/ 3/2020 5: 4: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 32 14.14 500 226 0.23 / 1042.20 3 3
2 12 1118.44 5 4.92 1814 45 0.27 / 1042.24 2 3
3 12 1216.36 65 8.22 2056 1099 1.37 / 1043.34 2 2
4 7 1221.08 24 10.51 2140 540 1.91 / 1043.88 2 2
5 13 1050.92 33 12.50 1925 794 2.70 / 1044.67 2 2
6 13 179.12 33 13.88 645 295 3.00 / 1044.97 2 2
7 14 -0.12 190 14.21 366 988 3.99 / 1045.96 2 7
Average= 5.05 (KJ/cycle)

Cycle 205 GMT 16/ 3/2020 10: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 31 14.19 504 222 0.22 / 1038.04 3 3
2 12 1121.24 5 5.02 2271 57 0.28 / 1038.10 2 2
3 12 1205.12 65 9.67 2052 1290 1.57 / 1039.39 2 2
4 7 1208.00 24 10.71 2119 545 2.11 / 1039.94 2 2
5 13 1011.48 33 12.64 1870 780 2.89 / 1040.72 2 3
6 13 129.12 33 14.00 569 263 3.16 / 1040.98 2 2
7 14 -0.12 190 14.21 367 991 4.15 / 1041.97 2 11
Average= 5.06 (KJ/cycle)

Cycle 204 GMT 6/ 3/2020 15: 7: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 32 14.16 493 223 0.22 / 1032.70 3 3
2 12 1105.12 5 11.57 1973 114 0.34 / 1032.81 2 2
3 12 2002.56 66 9.56 3215 2029 2.37 / 1034.84 2 2
4 7 1998.20 24 10.41 3233 808 3.17 / 1035.65 2 2
5 13 1105.28 34 12.89 1984 870 4.04 / 1036.52 2 3
6 13 195.76 34 13.96 677 321 4.36 / 1036.84 2 3
7 14 -0.08 190 14.29 362 983 5.35 / 1037.82 2 9
Average= 5.06 (KJ/cycle)

Cycle 203 GMT 5/ 3/2020 11:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 32 14.13 507 229 0.23 / 1028.72 3 3
2 12 1127.04 5 4.92 1814 45 0.27 / 1028.76 2 3
3 12 1210.44 65 8.10 2039 1074 1.35 / 1029.83 2 2
4 7 1216.56 24 10.55 2135 541 1.89 / 1030.38 2 2
5 13 1061.76 34 12.48 1940 823 2.71 / 1031.20 2 3
6 13 189.04 34 13.89 655 309 3.02 / 1031.51 2 3
7 14 -0.04 190 14.23 358 968 3.99 / 1032.48 2 10
Average= 5.06 (KJ/cycle)

Cycle 202 GMT 24/ 2/2020 16:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 32 14.15 512 232 0.23 / 1024.46 3 3
2 12 1128.32 5 4.92 1829 45 0.28 / 1024.51 2 3
3 12 1218.64 66 8.58 2058 1165 1.44 / 1025.67 2 2
4 7 1222.72 24 10.57 2142 543 1.99 / 1026.21 2 2
5 13 1047.20 34 12.55 1905 813 2.80 / 1027.03 2 3
6 13 173.40 34 13.92 632 299 3.10 / 1027.33 2 2
7 13 7.52 34 14.23 371 179 3.28 / 1027.51 2 3
8 14 -0.08 190 14.23 363 981 4.26 / 1028.49 3 11
Average= 5.07 (KJ/cycle)

Cycle 201 GMT 14/ 2/2020 21:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 31 14.24 493 218 0.22 / 1020.42 3 3
2 12 1133.12 5 5.05 2371 60 0.28 / 1020.48 2 2
3 12 1206.32 65 9.91 2053 1322 1.60 / 1021.80 2 2
4 7 1209.60 24 10.82 2083 541 2.14 / 1022.34 2 2
5 13 811.04 33 13.01 1563 671 2.81 / 1023.01 2 3
6 13 81.48 33 14.13 489 228 3.04 / 1023.24 2 3
7 14 -0.08 190 14.26 365 989 4.03 / 1024.23 2 9
Average= 5.07 (KJ/cycle)

Cycle 200 GMT 5/ 2/2020 2:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.56 31 14.13 514 225 0.23 / 1015.08 3 3
2 12 1131.04 5 11.60 2027 118 0.34 / 1015.20 2 2
3 12 2007.60 65 9.70 3242 2044 2.39 / 1017.24 2 2
4 7 2002.72 24 10.34 3250 807 3.19 / 1018.05 2 2
5 13 1127.32 33 12.88 2019 858 4.05 / 1018.91 2 3
6 13 214.04 33 13.95 699 322 4.37 / 1019.23 2 2
7 14 -0.04 190 14.30 358 973 5.35 / 1020.20 2 8
Average= 5.08 (KJ/cycle)

Cycle 199 GMT 3/ 2/2020 22:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 32 14.15 510 231 0.23 / 1011.08 3 3
2 12 1118.72 5 4.94 1897 47 0.28 / 1011.13 2 3
3 12 1202.16 65 8.33 2033 1101 1.38 / 1012.23 2 2
4 7 1206.76 25 10.57 2111 558 1.94 / 1012.79 2 2
5 13 1034.36 33 12.52 1897 784 2.72 / 1013.57 2 2
6 13 188.12 33 13.89 658 302 3.02 / 1013.87 2 2
7 14 -0.08 190 14.21 363 980 4.00 / 1014.85 2 7
Average= 5.07 (KJ/cycle)

Cycle 198 GMT 25/ 1/2020 3:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 32 14.18 503 228 0.23 / 1007.00 3 3
2 12 1110.84 5 4.96 1974 49 0.28 / 1007.04 2 3
3 12 1207.52 65 8.95 2052 1194 1.47 / 1008.24 2 2
4 7 1212.04 24 10.69 2125 545 2.02 / 1008.78 2 2
5 13 1022.44 34 12.59 1889 809 2.82 / 1009.59 2 2
6 13 157.60 34 13.93 611 289 3.11 / 1009.88 2 3
7 14 -0.04 190 14.23 359 971 4.08 / 1010.85 2 7
Average= 5.08 (KJ/cycle)

Cycle 197 GMT 15/ 1/2020 8:51: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 32 14.18 511 232 0.23 / 1002.93 3 3
2 3 966.08 -1 14.18 511 0 0.00 / 1002.93 3 3
3 3 1024.00 1 12.13 1864 23 0.25 / 1002.95 2 2
4 12 1155.56 5 7.15 1952 70 0.32 / 1003.02 2 2
5 12 1200.76 65 9.77 2063 1310 1.63 / 1004.33 2 2
6 7 1202.68 24 10.80 2115 548 2.18 / 1004.88 2 2
7 13 810.24 33 13.01 1571 674 2.86 / 1005.55 2 3
8 13 78.64 33 14.12 493 230 3.09 / 1005.78 2 3
9 14 -0.16 191 14.25 361 983 4.07 / 1006.77 2 12
Average= 5.08 (KJ/cycle)

Cycle 196 GMT 5/ 1/2020 13:51: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 31 14.16 510 224 0.22 / 997.40 3 3
2 12 1096.32 5 11.70 1978 116 0.34 / 997.52 2 2
3 12 2000.72 65 9.75 3228 2046 2.39 / 999.56 2 2
4 7 1994.64 25 10.38 3234 839 3.22 / 1000.40 2 2
5 13 1257.32 33 12.73 2202 925 4.15 / 1001.33 2 2
6 13 297.40 33 13.80 831 378 4.53 / 1001.70 2 3
7 14 -0.08 190 14.25 367 994 5.52 / 1002.70 2 10
Average= 5.09 (KJ/cycle)

Cycle 195 GMT 4/ 1/2020 10:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 31 14.15 512 225 0.22 / 993.39 3 3
2 12 1116.12 5 4.94 1902 47 0.27 / 993.44 2 3
3 12 1191.36 65 8.70 2019 1142 1.41 / 994.58 2 2
4 7 1194.16 25 10.64 2074 552 1.96 / 995.13 2 2
5 13 1012.88 33 12.59 1857 772 2.74 / 995.91 2 3
6 13 163.04 34 13.93 622 295 3.03 / 996.20 2 3
7 14 -0.08 190 14.22 361 975 4.01 / 997.18 2 6
Average= 5.09 (KJ/cycle)

Cycle 194 GMT 25/12/2019 15:20: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 32 14.14 528 239 0.24 / 989.45 3 3
2 3 959.52 -1 14.14 528 0 0.00 / 989.45 3 3
3 3 1022.80 1 11.81 1856 22 0.26 / 989.47 2 2
4 12 1157.08 5 4.97 2012 50 0.31 / 989.52 2 3
5 12 1201.64 65 9.00 2036 1191 1.50 / 990.71 2 2
6 7 1205.16 24 10.66 2110 540 2.04 / 991.25 2 2
7 13 836.64 33 12.94 1606 686 2.73 / 991.94 2 3
8 13 90.04 33 14.08 509 237 2.96 / 992.17 2 2
9 14 0.08 190 14.23 368 995 3.96 / 993.17 2 9
Average= 5.09 (KJ/cycle)

Cycle 193 GMT 15/12/2019 20:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 29 14.20 516 212 0.21 / 985.19 3 3
2 3 1086.24 2 12.57 1962 49 0.26 / 985.24 2 2
3 3 1040.76 1 12.31 1882 23 0.28 / 985.26 2 2
4 12 1144.44 5 7.22 1930 70 0.35 / 985.33 2 2
5 12 1208.08 65 9.80 2075 1322 1.68 / 986.65 2 2
6 7 1211.40 24 10.80 2130 552 2.23 / 987.20 2 2
7 13 1019.12 33 12.73 1858 781 3.01 / 987.98 2 3
8 13 77.32 33 14.13 482 225 3.23 / 988.21 2 2
9 14 -0.12 190 14.24 370 1001 4.23 / 989.21 2 11
Average= 5.10 (KJ/cycle)

Cycle 192 GMT 6/12/2019 1:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 32 14.12 510 230 0.23 / 979.80 3 3
2 3 966.40 -1 14.12 510 0 0.00 / 979.80 3 3
3 3 1030.44 1 11.85 1867 22 0.25 / 979.82 2 2
4 12 1149.52 5 11.80 2076 122 0.38 / 979.94 2 2
5 12 2001.44 65 9.97 3233 2095 2.47 / 982.04 2 2
6 7 1995.48 24 10.44 3236 811 3.28 / 982.85 2 2
7 13 1076.60 33 12.95 1934 826 4.11 / 983.67 2 3
8 13 181.84 33 13.99 652 301 4.41 / 983.97 2 3
9 14 -0.08 190 14.28 369 1001 5.41 / 984.98 2 8
Average= 5.10 (KJ/cycle)

Cycle 191 GMT 4/12/2019 22: 7:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 32 14.12 513 232 0.23 / 975.74 3 3
2 12 1099.24 5 4.95 1987 49 0.28 / 975.79 2 3
3 12 1207.20 65 8.62 2067 1158 1.44 / 976.95 2 2
4 7 1211.28 25 10.61 2136 567 2.01 / 977.52 2 2
5 13 1012.84 33 12.58 1855 770 2.78 / 978.29 2 2
6 13 160.88 33 13.92 617 283 3.06 / 978.57 2 2
7 14 -0.16 190 14.19 369 995 4.05 / 979.57 2 9
Average= 5.10 (KJ/cycle)

Cycle 190 GMT 25/11/2019 3:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 28 14.23 508 202 0.20 / 971.48 3 3
2 10 1008.88 3 12.97 1869 73 0.28 / 971.55 2 2
3 3 1025.16 1 12.12 1868 23 0.30 / 971.57 2 2
4 3 1023.72 1 11.90 1851 22 0.32 / 971.59 2 2
5 12 1153.20 5 7.33 1977 72 0.39 / 971.67 2 2
6 12 1202.16 65 9.67 2059 1294 1.69 / 972.96 2 2
7 7 1205.60 25 10.71 2123 568 2.25 / 973.53 2 2
8 13 1011.72 33 12.69 1851 775 3.03 / 974.30 2 3
9 13 66.32 33 14.14 471 220 3.25 / 974.52 2 3
10 14 -0.04 190 14.24 365 988 4.24 / 975.51 2 12
Average= 5.11 (KJ/cycle)

Cycle 189 GMT 15/11/2019 8:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 32 14.23 511 233 0.23 / 965.79 3 3
2 12 1106.04 5 7.57 1881 71 0.30 / 965.87 2 2
3 12 2006.24 65 6.69 3167 1377 1.68 / 967.24 2 2
4 7 2005.84 24 9.88 3202 759 2.44 / 968.00 2 2
5 13 1655.68 33 12.11 2759 1103 3.54 / 969.10 2 2
6 13 1213.52 33 12.79 2153 909 4.45 / 970.01 2 3
7 13 125.40 33 14.09 564 262 4.71 / 970.28 2 3
8 14 -0.16 190 14.29 368 999 5.71 / 971.27 2 10
Average= 5.11 (KJ/cycle)

Cycle 188 GMT 5/11/2019 7:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 32 14.17 518 235 0.23 / 959.95 2 3
2 12 1097.56 5 8.19 1891 77 0.31 / 960.03 2 2
3 12 2004.56 65 6.62 3141 1352 1.66 / 961.38 2 2
4 7 2004.96 25 9.92 3180 789 2.45 / 962.17 2 2
5 13 1832.04 34 11.83 3013 1212 3.66 / 963.38 2 2
6 13 1161.52 34 12.86 2062 902 4.57 / 964.28 2 3
7 13 127.92 34 14.11 571 274 4.84 / 964.56 2 3
8 14 -0.04 190 14.30 370 1005 5.85 / 965.56 2 10
Average= 5.11 (KJ/cycle)

Cycle 187 GMT 26/10/2019 7:30: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 32 14.23 512 233 0.23 / 954.20 3 3
2 12 1115.12 5 7.38 1901 70 0.30 / 954.27 2 2
3 12 2006.36 65 6.75 3106 1363 1.67 / 955.63 2 2
4 7 2006.16 25 9.94 3182 791 2.46 / 956.42 2 2
5 13 1827.80 34 11.84 3004 1209 3.67 / 957.63 2 2
6 13 965.08 34 13.06 1800 799 4.47 / 958.43 2 3
7 13 127.68 34 14.10 574 275 4.74 / 958.71 2 3
8 14 0.00 190 14.30 371 1008 5.75 / 959.72 2 7
Average= 5.10 (KJ/cycle)

Cycle 186 GMT 16/10/2019 7: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 32 14.19 515 234 0.23 / 948.42 3 3
2 12 1121.56 5 7.90 1915 76 0.31 / 948.49 2 2
3 12 2007.12 65 6.97 3193 1447 1.76 / 949.94 2 2
4 7 2008.24 24 10.00 3190 766 2.52 / 950.70 2 2
5 13 1816.40 34 11.91 2980 1207 3.73 / 951.91 2 2
6 13 952.80 34 13.08 1780 792 4.52 / 952.70 2 3
7 13 120.36 34 14.12 557 267 4.79 / 952.97 2 3
8 14 0.00 190 14.31 367 998 5.79 / 953.97 2 12
Average= 5.10 (KJ/cycle)

Cycle 185 GMT 6/10/2019 6:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 32 14.21 519 236 0.24 / 942.72 3 3
2 12 1131.68 5 8.13 1928 78 0.31 / 942.80 2 2
3 12 2003.12 65 7.22 3173 1489 1.80 / 944.29 2 2
4 7 2003.12 24 9.99 3185 764 2.57 / 945.05 2 2
5 13 1803.20 33 11.91 2951 1160 3.73 / 946.21 2 2
6 13 917.88 33 13.11 1732 749 4.48 / 946.96 2 3
7 13 114.84 33 14.17 539 252 4.73 / 947.21 2 3
8 14 -0.04 190 14.35 356 971 5.70 / 948.18 2 8
Average= 5.10 (KJ/cycle)

Cycle 184 GMT 26/ 9/2019 6:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 31 14.23 525 232 0.23 / 936.92 3 3
2 12 1131.68 5 7.99 1921 77 0.31 / 937.00 2 2
3 12 2002.92 66 7.16 3118 1473 1.78 / 938.47 2 2
4 7 2002.48 24 10.04 3183 767 2.55 / 939.24 2 2
5 13 1805.40 34 11.91 2976 1205 3.75 / 940.44 2 2
6 13 929.12 34 13.11 1748 779 4.53 / 941.22 2 3
7 13 122.08 34 14.15 557 268 4.80 / 941.49 2 3
8 14 -0.08 190 14.33 365 994 5.79 / 942.48 2 9
Average= 5.09 (KJ/cycle)

Cycle 183 GMT 16/ 9/2019 6:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 31 14.21 519 229 0.23 / 931.08 2 3
2 12 1130.56 5 8.80 1942 85 0.31 / 931.16 2 2
3 12 2006.12 65 7.28 3206 1517 1.83 / 932.68 2 2
4 7 2005.84 25 9.98 3238 808 2.64 / 933.49 2 2
5 13 1812.56 33 11.88 2990 1172 3.81 / 934.66 2 2
6 13 929.16 33 13.10 1756 759 4.57 / 935.42 2 3
7 13 115.76 33 14.13 562 262 4.83 / 935.68 2 3
8 14 -0.08 190 14.31 370 1006 5.84 / 936.69 2 11
Average= 5.09 (KJ/cycle)

Cycle 182 GMT 6/ 9/2019 6:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 31 14.23 514 227 0.23 / 925.24 3 3
2 3 1020.52 1 12.46 1879 23 0.25 / 925.26 2 2
3 12 1135.28 5 8.09 1957 79 0.33 / 925.34 2 2
4 12 2002.76 65 7.47 3125 1517 1.85 / 926.86 2 2
5 7 2001.32 25 10.02 3177 796 2.64 / 927.66 2 2
6 13 1806.84 34 11.90 2967 1200 3.84 / 928.86 2 2
7 13 873.80 34 13.15 1673 748 4.59 / 929.60 2 3
8 13 78.80 34 14.19 498 240 4.83 / 929.84 2 3
9 14 0.04 190 14.31 370 1006 5.84 / 930.85 2 13
Average= 5.09 (KJ/cycle)

Cycle 181 GMT 27/ 8/2019 6:19: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 32 14.24 509 232 0.23 / 919.66 3 3
2 3 970.08 -1 14.24 509 0 0.00 / 919.66 3 3
3 12 1161.12 5 8.03 1960 79 0.31 / 919.74 2 2
4 12 2002.08 65 7.48 3189 1550 1.86 / 921.29 2 2
5 7 1999.88 24 10.03 3200 770 2.63 / 922.06 2 2
6 13 1602.24 33 12.20 2677 1078 3.71 / 923.14 2 2
7 13 748.72 33 13.29 1485 651 4.36 / 923.79 2 3
8 13 62.16 33 14.22 474 222 4.58 / 924.01 2 3
9 14 -0.16 190 14.30 368 1000 5.58 / 925.01 2 9
Average= 5.08 (KJ/cycle)

Cycle 180 GMT 17/ 8/2019 6: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 32 14.24 506 231 0.23 / 913.97 3 3
2 12 1104.36 5 8.44 1887 80 0.31 / 914.05 2 2
3 12 2004.44 65 7.57 3163 1556 1.87 / 915.60 2 2
4 7 2002.08 25 10.02 3232 810 2.68 / 916.41 2 2
5 13 1614.56 34 12.18 2711 1123 3.80 / 917.53 2 3
6 13 753.48 34 13.28 1494 675 4.47 / 918.21 2 3
7 13 58.04 34 14.23 458 222 4.70 / 918.43 2 3
8 14 -0.08 190 14.30 368 1000 5.69 / 919.43 2 11
Average= 5.08 (KJ/cycle)

Cycle 179 GMT 7/ 8/2019 5: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 32 14.22 520 237 0.24 / 907.93 3 3
2 12 1113.36 5 8.79 1913 84 0.32 / 908.01 2 2
3 12 2006.40 65 7.53 3136 1535 1.86 / 909.55 2 2
4 7 2004.48 24 10.01 3238 778 2.63 / 910.33 2 2
5 13 1803.32 33 11.92 2967 1167 3.80 / 911.49 2 2
6 13 1412.36 33 12.59 2407 1000 4.80 / 912.49 2 2
7 13 94.60 33 14.17 520 243 5.04 / 912.74 2 3
8 14 0.12 190 14.31 368 1001 6.04 / 913.74 2 16
Average= 5.08 (KJ/cycle)

Cycle 178 GMT 28/ 7/2019 4:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 32 14.23 511 233 0.23 / 902.15 3 3
2 3 972.72 -1 14.23 511 0 0.00 / 902.15 3 3
3 3 1041.92 1 12.60 1889 24 0.26 / 902.17 2 2
4 12 1145.08 5 8.12 1943 79 0.34 / 902.25 2 2
5 12 2006.44 65 7.51 3137 1531 1.87 / 903.78 2 2
6 7 2005.80 25 10.05 3247 816 2.68 / 904.60 2 2
7 13 1806.60 34 11.91 2987 1210 3.89 / 905.81 2 2
8 13 725.36 34 13.32 1452 658 4.55 / 906.47 2 3
9 13 55.68 34 14.24 457 221 4.77 / 906.69 2 3
10 14 -0.04 190 14.30 369 1003 5.77 / 907.69 2 10
Average= 5.07 (KJ/cycle)

Cycle 177 GMT 18/ 7/2019 4:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 32 14.26 516 235 0.24 / 896.32 3 3
2 12 1095.92 5 8.44 1878 79 0.31 / 896.40 2 2
3 12 2004.20 65 7.64 3162 1570 1.88 / 897.97 2 2
4 7 2003.20 24 10.10 3224 781 2.67 / 898.76 2 2
5 13 1800.92 33 11.88 2992 1173 3.84 / 899.93 2 2
6 13 891.28 34 13.13 1696 757 4.60 / 900.69 2 3
7 13 73.84 34 14.22 485 234 4.83 / 900.92 2 3
8 14 -0.12 190 14.31 367 998 5.83 / 901.92 2 11
Average= 5.07 (KJ/cycle)

Cycle 176 GMT 8/ 7/2019 4:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 32 14.27 507 232 0.23 / 890.68 3 3
2 12 1102.56 5 8.46 1876 79 0.31 / 890.76 2 2
3 12 2003.52 65 7.86 3191 1630 1.94 / 892.39 2 2
4 7 2002.72 24 10.10 3221 781 2.72 / 893.17 2 2
5 13 1603.72 33 12.22 2679 1080 3.80 / 894.25 2 3
6 13 738.76 33 13.31 1471 646 4.45 / 894.90 2 3
7 13 56.24 33 14.27 443 209 4.66 / 895.11 2 3
8 14 -0.08 190 14.33 361 983 5.64 / 896.09 2 11
Average= 5.06 (KJ/cycle)

Cycle 175 GMT 28/ 6/2019 4: 2: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 32 14.25 509 232 0.23 / 884.96 3 3
2 12 1108.72 5 9.37 1900 89 0.32 / 885.05 2 2
3 12 2000.92 65 8.22 3184 1701 2.02 / 886.75 2 2
4 7 1999.16 24 10.22 3205 786 2.81 / 887.54 2 2
5 13 1584.44 34 12.27 2641 1102 3.91 / 888.64 2 3
6 13 689.80 34 13.36 1400 636 4.55 / 889.27 2 3
7 13 45.28 34 14.29 427 207 4.75 / 889.48 2 3
8 14 0.04 190 14.32 356 969 5.72 / 890.45 2 13
Average= 5.06 (KJ/cycle)

Cycle 174 GMT 18/ 6/2019 3:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 32 14.23 505 230 0.23 / 879.52 3 3
2 12 1112.68 2 4.99 1994 20 0.25 / 879.54 2 3
3 7 2003.60 50 7.99 3136 1253 1.50 / 880.80 3 2
4 13 1879.36 33 11.71 3069 1186 2.69 / 881.98 2 2
5 13 1463.80 33 12.44 2480 1018 3.71 / 883.00 2 2
6 13 573.96 33 13.48 1237 550 4.26 / 883.55 2 3
7 13 27.76 33 14.30 407 192 4.45 / 883.74 2 3
8 14 -0.04 191 14.29 361 985 5.43 / 884.73 2 12
Average= 5.06 (KJ/cycle)

Cycle 173 GMT 8/ 6/2019 3:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 32 14.27 499 228 0.23 / 874.02 3 3
2 12 1108.64 2 4.99 1982 20 0.25 / 874.04 2 2
3 7 2006.48 50 7.96 3193 1271 1.52 / 875.32 2 2
4 13 1863.08 34 11.74 3066 1224 2.74 / 876.54 2 2
5 13 1446.44 34 12.46 2458 1041 3.78 / 877.58 2 3
6 13 545.80 34 13.52 1192 548 4.33 / 878.13 2 3
7 13 10.12 34 14.32 378 184 4.52 / 878.31 2 3
8 14 -0.04 190 14.29 361 980 5.50 / 879.29 2 7
Average= 5.05 (KJ/cycle)

Cycle 172 GMT 29/ 5/2019 3:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 32 14.27 492 225 0.22 / 868.48 3 3
2 12 1111.28 2 5.00 2024 20 0.24 / 868.50 2 2
3 7 2003.32 51 8.11 3131 1295 1.54 / 869.79 2 2
4 13 1883.92 34 11.71 3089 1230 2.77 / 871.02 2 2
5 13 1466.48 34 12.44 2478 1048 3.82 / 872.07 2 3
6 13 576.20 34 13.49 1225 562 4.38 / 872.63 2 3
7 13 27.88 34 14.29 402 195 4.58 / 872.83 2 3
8 14 -0.08 190 14.30 356 967 5.54 / 873.80 2 13
Average= 5.05 (KJ/cycle)

Cycle 171 GMT 19/ 5/2019 2:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 32 14.22 512 233 0.23 / 863.07 3 3
2 12 1125.44 2 4.99 2002 20 0.25 / 863.09 2 2
3 7 2006.00 50 8.18 3127 1279 1.53 / 864.37 2 2
4 13 1854.68 33 11.77 3053 1186 2.72 / 865.56 2 2
5 13 1440.00 33 12.46 2463 1013 3.73 / 866.57 2 3
6 13 543.84 33 13.54 1180 527 4.26 / 867.10 2 3
7 13 9.76 33 14.33 377 178 4.44 / 867.28 2 3
8 14 -0.16 190 14.27 361 979 5.41 / 868.25 2 10
Average= 5.05 (KJ/cycle)

Cycle 170 GMT 9/ 5/2019 2:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 32 14.27 495 226 0.23 / 857.72 3 3
2 7 2005.48 50 7.89 3044 1201 1.43 / 858.92 3 2
3 13 1880.44 33 11.75 3065 1188 2.62 / 860.11 2 2
4 13 1302.96 33 12.65 2248 938 3.55 / 861.05 2 3
5 13 630.04 33 13.44 1309 581 4.13 / 861.63 2 3
6 13 88.36 33 14.18 502 235 4.37 / 861.86 2 3
7 14 -0.04 190 14.28 360 977 5.35 / 862.84 2 16
Average= 5.05 (KJ/cycle)

Cycle 169 GMT 29/ 4/2019 2: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 32 14.23 504 230 0.23 / 852.44 3 3
2 7 2009.92 50 8.03 3045 1223 1.45 / 853.66 3 2
3 13 1879.44 34 11.79 3050 1223 2.67 / 854.88 2 2
4 13 1463.52 34 12.46 2487 1054 3.73 / 855.94 2 2
5 13 560.76 34 13.52 1214 558 4.29 / 856.50 2 2
6 14 -0.16 190 14.27 368 998 5.28 / 857.49 2 8
Average= 5.04 (KJ/cycle)

Cycle 168 GMT 19/ 4/2019 1:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 32 14.25 512 233 0.23 / 847.04 3 3
2 7 2003.92 50 8.15 3060 1247 1.48 / 848.29 3 2
3 13 1866.92 33 11.79 3051 1187 2.67 / 849.48 2 2
4 13 1443.48 33 12.51 2453 1013 3.68 / 850.49 2 2
5 13 547.56 33 13.53 1196 534 4.21 / 851.02 2 3
6 13 24.68 33 14.31 408 193 4.41 / 851.22 2 3
7 14 0.12 190 14.29 366 994 5.40 / 852.21 2 7
Average= 5.04 (KJ/cycle)

Cycle 167 GMT 9/ 4/2019 1:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 32 14.28 503 230 0.23 / 841.95 3 3
2 7 2004.36 50 8.21 3097 1271 1.50 / 843.22 3 2
3 13 1866.76 33 11.84 3055 1194 2.69 / 844.41 2 3
4 13 1284.52 33 12.73 2235 939 3.63 / 845.35 2 2
5 13 432.08 33 13.68 1029 465 4.10 / 845.82 2 3
6 14 -0.04 190 14.29 365 991 5.09 / 846.81 2 9
Average= 5.04 (KJ/cycle)

Cycle 166 GMT 30/ 3/2019 1: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 32 14.26 507 231 0.23 / 836.38 3 3
2 7 2002.84 51 8.29 3137 1326 1.56 / 837.71 2 2
3 13 1869.96 34 11.82 3084 1239 2.80 / 838.95 2 2
4 13 1466.92 34 12.53 2488 1060 3.86 / 840.01 2 2
5 13 559.32 33 13.54 1212 542 4.40 / 840.55 2 3
6 13 5.76 33 14.33 377 178 4.58 / 840.73 2 3
7 14 -0.12 190 14.27 367 995 5.57 / 841.72 2 9
Average= 5.04 (KJ/cycle)

Cycle 165 GMT 20/ 3/2019 0:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 32 14.27 509 232 0.23 / 831.27 3 3
2 7 2010.28 50 8.37 3110 1302 1.53 / 832.57 2 2
3 13 1867.72 33 11.86 3042 1191 2.72 / 833.76 2 2
4 13 1269.32 33 12.77 2212 932 3.66 / 834.69 2 3
5 13 412.04 34 13.71 1001 467 4.12 / 835.16 2 3
6 14 -0.12 190 14.27 365 990 5.11 / 836.15 2 9
Average= 5.04 (KJ/cycle)

Cycle 164 GMT 10/ 3/2019 0:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 32 14.30 510 233 0.23 / 826.21 3 3
2 7 2000.76 50 8.45 3054 1290 1.52 / 827.50 2 2
3 13 1859.36 33 11.88 3021 1184 2.71 / 828.68 2 2
4 13 1253.40 33 12.77 2188 922 3.63 / 829.60 2 3
5 13 376.16 33 13.75 951 432 4.06 / 830.04 2 2
6 14 0.00 190 14.26 369 1000 5.06 / 831.04 2 7
Average= 5.04 (KJ/cycle)

Cycle 163 GMT 27/ 2/2019 23:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 32 14.25 510 233 0.23 / 820.93 2 3
2 7 2002.80 50 8.38 3137 1314 1.55 / 822.24 2 2
3 13 1867.12 33 11.87 3055 1197 2.74 / 823.44 2 2
4 13 1435.92 33 12.58 2443 1014 3.76 / 824.45 2 3
5 13 525.36 33 13.57 1166 522 4.28 / 824.98 2 3
6 14 -0.12 190 14.24 369 998 5.28 / 825.97 2 9
Average= 5.04 (KJ/cycle)

Cycle 162 GMT 17/ 2/2019 23:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 32 14.25 513 234 0.23 / 815.68 3 3
2 7 2001.24 50 8.47 3103 1314 1.55 / 816.99 3 2
3 13 1859.48 33 11.85 3054 1194 2.74 / 818.19 2 2
4 13 1241.24 34 12.78 2176 946 3.69 / 819.13 2 3
5 13 549.88 34 13.53 1196 550 4.24 / 819.68 2 3
6 14 -0.08 190 14.21 375 1012 5.25 / 820.70 2 11
Average= 5.03 (KJ/cycle)

Cycle 161 GMT 7/ 2/2019 23:51: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 32 14.24 516 235 0.24 / 810.12 2 3
2 7 2000.84 51 8.61 3098 1360 1.60 / 811.48 3 2
3 13 1845.24 34 11.88 3036 1226 2.82 / 812.71 2 2
4 13 1246.20 34 12.77 2190 951 3.77 / 813.66 2 3
5 13 554.64 34 13.51 1216 559 4.33 / 814.22 2 3
6 13 20.92 34 14.26 419 203 4.53 / 814.42 2 3
7 14 0.12 190 14.20 380 1025 5.56 / 815.45 2 7
Average= 5.03 (KJ/cycle)

Cycle 160 GMT 28/ 1/2019 23:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 32 14.25 520 237 0.24 / 804.87 3 3
2 3 973.20 -1 14.25 520 0 0.00 / 804.87 3 3
3 3 1034.52 1 12.77 1884 24 0.26 / 804.89 2 2
4 7 2002.48 51 8.69 3115 1381 1.64 / 806.27 2 2
5 13 1851.88 34 11.88 3035 1226 2.87 / 807.50 2 2
6 13 1230.52 34 12.79 2165 941 3.81 / 808.44 2 3
7 13 345.64 34 13.77 913 427 4.24 / 808.87 2 3
8 14 0.00 190 14.20 378 1020 5.26 / 809.89 2 12
Average= 5.03 (KJ/cycle)

Cycle 159 GMT 18/ 1/2019 23:28: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 32 14.26 515 235 0.24 / 799.55 2 3
2 7 2001.92 50 8.68 3134 1360 1.60 / 800.91 3 2
3 13 1841.24 33 11.88 3047 1195 2.79 / 802.10 2 2
4 13 1404.96 33 12.62 2418 1007 3.80 / 803.11 2 3
5 13 484.32 33 13.59 1109 497 4.29 / 803.61 2 3
6 14 0.04 190 14.21 378 1021 5.31 / 804.63 2 12
Average= 5.03 (KJ/cycle)

Cycle 158 GMT 8/ 1/2019 23:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 33 14.23 520 244 0.24 / 794.36 3 3
2 3 972.68 -1 14.23 520 0 0.00 / 794.36 3 3
3 3 1033.72 1 12.77 1873 24 0.27 / 794.38 2 2
4 7 2001.56 50 8.81 3127 1377 1.65 / 795.76 2 2
5 13 1852.00 33 11.88 3056 1198 2.84 / 796.96 2 2
6 13 1224.04 33 12.80 2160 912 3.76 / 797.87 2 3
7 13 341.52 33 13.78 908 413 4.17 / 798.28 2 3
8 14 0.00 190 14.20 382 1031 5.20 / 799.31 2 7
Average= 5.03 (KJ/cycle)

Cycle 157 GMT 29/12/2018 23: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 33 14.24 513 241 0.24 / 789.14 2 3
2 7 2002.20 51 8.70 3098 1375 1.62 / 790.51 3 2
3 13 1840.88 34 11.88 3039 1228 2.84 / 791.74 2 2
4 13 1226.56 34 12.80 2150 936 3.78 / 792.67 2 3
5 13 337.60 34 13.78 902 423 4.20 / 793.10 2 3
6 14 -0.16 190 14.18 378 1018 5.22 / 794.11 2 12
Average= 5.03 (KJ/cycle)

Cycle 156 GMT 19/12/2018 22:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 33 14.22 520 244 0.24 / 783.98 2 3
2 7 2005.56 50 8.82 3127 1379 1.62 / 785.36 3 2
3 13 1856.64 33 11.89 3050 1197 2.82 / 786.56 2 2
4 13 1220.68 33 12.81 2157 912 3.73 / 787.47 2 3
5 13 336.40 33 13.80 892 406 4.14 / 787.88 2 3
6 14 -0.04 190 14.20 378 1020 5.16 / 788.90 2 9
Average= 5.02 (KJ/cycle)

Cycle 155 GMT 9/12/2018 22:39:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 33 14.23 534 251 0.25 / 778.82 2 3
2 7 2003.40 50 8.87 3088 1370 1.62 / 780.19 3 2
3 13 1843.08 33 11.93 3035 1195 2.82 / 781.38 2 2
4 13 1216.32 34 12.82 2140 933 3.75 / 782.31 2 3
5 13 325.88 34 13.82 875 411 4.16 / 782.72 2 3
6 14 -0.12 190 14.22 375 1013 5.17 / 783.74 2 13
Average= 5.02 (KJ/cycle)

Cycle 154 GMT 29/11/2018 22:21: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 33 14.21 534 250 0.25 / 773.62 2 3
2 7 2006.84 50 8.97 3130 1404 1.65 / 775.02 3 2
3 13 1843.92 33 11.97 3044 1202 2.86 / 776.22 2 2
4 13 1232.08 33 12.82 2166 916 3.77 / 777.14 2 3
5 13 341.64 33 13.80 900 410 4.18 / 777.55 2 3
6 14 -0.04 190 14.20 377 1017 5.20 / 778.57 2 8
Average= 5.02 (KJ/cycle)

Cycle 153 GMT 19/11/2018 22: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 33 14.22 524 246 0.25 / 768.45 2 3
2 7 2003.64 50 9.05 3123 1413 1.66 / 769.86 3 2
3 13 1840.52 33 12.00 3023 1197 2.86 / 771.06 2 2
4 13 1218.24 33 12.83 2139 906 3.76 / 771.96 2 3
5 13 304.84 33 13.83 845 386 4.15 / 772.35 2 3
6 14 0.12 190 14.20 377 1017 5.16 / 773.37 2 11
Average= 5.02 (KJ/cycle)

Cycle 152 GMT 9/11/2018 21:50: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 33 14.21 538 252 0.25 / 763.16 2 3
2 7 2000.88 51 9.20 3106 1457 1.71 / 764.62 2 2
3 13 1838.88 34 12.01 3029 1237 2.95 / 765.85 2 2
4 13 1216.76 34 12.83 2138 933 3.88 / 766.79 2 3
5 13 310.56 34 13.84 852 401 4.28 / 767.19 2 3
6 14 -0.08 190 14.21 375 1012 5.29 / 768.20 2 9
Average= 5.02 (KJ/cycle)

Cycle 151 GMT 30/10/2018 21:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 33 14.18 530 248 0.25 / 758.07 2 3
2 7 2000.92 50 9.21 3118 1436 1.68 / 759.50 3 2
3 13 1848.12 33 12.07 3013 1200 2.88 / 760.70 2 2
4 13 1203.52 33 12.86 2117 898 3.78 / 761.60 2 3
5 13 168.28 33 14.05 634 294 4.08 / 761.89 2 3
6 14 -0.08 190 14.22 375 1013 5.09 / 762.91 2 13
Average= 5.02 (KJ/cycle)

Cycle 150 GMT 20/10/2018 21:22: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 33 14.22 532 250 0.25 / 752.93 2 3
2 7 2004.08 50 9.26 3139 1453 1.70 / 754.39 2 2
3 13 1850.40 33 12.10 3034 1211 2.91 / 755.60 2 2
4 13 1210.68 33 12.85 2131 904 3.82 / 756.50 2 3
5 13 161.32 33 14.06 632 293 4.11 / 756.80 2 3
6 14 0.12 191 14.20 377 1022 5.13 / 757.82 2 9
Average= 5.02 (KJ/cycle)

Cycle 149 GMT 10/10/2018 21: 7: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 33 14.17 545 255 0.25 / 747.70 2 3
2 7 2003.36 50 9.32 3140 1463 1.72 / 749.16 2 2
3 13 1839.08 33 12.12 3032 1213 2.93 / 750.38 2 2
4 13 1210.80 33 12.86 2128 903 3.83 / 751.28 2 3
5 13 302.00 33 13.87 840 384 4.22 / 751.66 2 3
6 14 -0.12 190 14.21 378 1021 5.24 / 752.68 2 12
Average= 5.02 (KJ/cycle)

Cycle 148 GMT 30/ 9/2018 20:54: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 33 14.20 531 249 0.25 / 742.48 2 2
2 7 2000.84 50 9.44 3157 1490 1.74 / 743.98 2 2
3 13 1838.24 33 12.13 3008 1204 2.94 / 745.18 2 2
4 13 1180.84 33 12.89 2085 887 3.83 / 746.07 2 3
5 13 257.08 33 13.93 773 355 4.19 / 746.42 2 3
6 14 0.08 190 14.19 380 1025 5.21 / 747.45 2 13
Average= 5.02 (KJ/cycle)

Cycle 147 GMT 20/ 9/2018 20:54: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 33 14.15 539 252 0.25 / 737.10 2 2
2 7 2001.60 51 9.53 3152 1532 1.78 / 738.63 2 2
3 13 1843.36 34 12.15 3028 1251 3.03 / 739.88 2 2
4 13 1211.48 34 12.84 2140 934 3.97 / 740.81 2 3
5 13 286.68 34 13.87 823 388 4.36 / 741.20 2 3
6 14 -0.16 190 14.16 384 1033 5.39 / 742.24 2 12
Average= 5.02 (KJ/cycle)

Cycle 146 GMT 10/ 9/2018 20:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 33 14.19 545 255 0.26 / 731.90 2 3
2 7 2003.08 50 9.63 3164 1523 1.78 / 733.43 3 2
3 13 1844.04 33 12.14 3035 1216 2.99 / 734.64 2 2
4 13 1182.88 33 12.88 2096 891 3.89 / 735.53 2 4
5 13 142.48 33 14.08 607 282 4.17 / 735.81 2 3
6 14 0.00 190 14.18 383 1032 5.20 / 736.85 2 14
Average= 5.01 (KJ/cycle)

Cycle 145 GMT 31/ 8/2018 20:37: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 33 14.17 526 246 0.25 / 726.71 2 2
2 7 2006.52 50 9.67 3199 1547 1.79 / 728.25 2 2
3 13 1818.80 33 12.20 2983 1201 2.99 / 729.46 2 2
4 13 1166.68 33 12.90 2076 884 3.88 / 730.34 2 3
5 13 126.52 33 14.10 587 273 4.15 / 730.61 2 3
6 14 -0.04 190 14.18 384 1035 5.19 / 731.65 2 10
Average= 5.01 (KJ/cycle)

Cycle 144 GMT 21/ 8/2018 20:35:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 33 14.17 540 253 0.25 / 721.49 2 2
2 7 2003.00 50 9.89 3171 1568 1.82 / 723.05 2 2
3 13 1828.60 33 12.21 2991 1205 3.03 / 724.26 2 3
4 13 1172.56 33 12.89 2089 889 3.91 / 725.15 2 3
5 13 128.52 33 14.10 590 275 4.19 / 725.42 2 3
6 14 0.04 191 14.18 384 1040 5.23 / 726.46 2 12
Average= 5.01 (KJ/cycle)

Cycle 143 GMT 11/ 8/2018 20:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 33 14.21 528 248 0.25 / 716.09 2 2
2 7 2004.44 51 9.86 3175 1597 1.84 / 717.69 2 2
3 13 1819.68 34 12.17 3002 1242 3.09 / 718.93 2 3
4 13 1176.76 34 12.89 2092 917 4.00 / 719.85 2 3
5 13 250.56 34 13.92 764 362 4.36 / 720.21 2 3
6 14 -0.08 190 14.17 381 1026 5.39 / 721.23 2 17
Average= 5.01 (KJ/cycle)

Cycle 142 GMT 1/ 8/2018 20:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 33 14.19 538 252 0.25 / 710.87 2 3
2 7 2000.84 51 10.00 3178 1621 1.87 / 712.49 3 2
3 13 1823.04 34 12.18 2998 1242 3.11 / 713.73 2 2
4 13 983.44 34 13.07 1810 804 3.92 / 714.54 2 3
5 13 134.60 34 14.08 592 283 4.20 / 714.82 2 3
6 14 0.04 190 14.18 380 1024 5.23 / 715.84 2 20
Average= 5.01 (KJ/cycle)

Cycle 141 GMT 22/ 7/2018 20:19:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 33 14.22 536 252 0.25 / 705.56 2 3
2 7 2003.32 51 10.04 3196 1636 1.89 / 707.19 2 2
3 13 1827.56 33 12.19 2992 1204 3.09 / 708.40 2 2
4 13 1148.60 33 12.91 2042 870 3.96 / 709.27 2 3
5 13 200.48 33 14.00 692 320 4.28 / 709.59 2 3
6 14 -0.08 190 14.17 383 1031 5.31 / 710.62 2 10
Average= 5.00 (KJ/cycle)

Cycle 140 GMT 12/ 7/2018 20:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 33 14.22 520 244 0.24 / 700.19 2 2
2 3 970.68 -1 14.22 520 0 0.00 / 700.19 2 2
3 3 1042.12 1 12.48 1895 24 0.27 / 700.22 2 2
4 7 2007.52 51 10.21 3183 1657 1.93 / 701.87 2 2
5 13 1830.36 34 12.19 3007 1246 3.17 / 703.12 2 2
6 13 1160.52 34 12.91 2059 904 4.08 / 704.02 2 3
7 13 99.52 34 14.15 533 256 4.33 / 704.28 2 3
8 14 -0.04 190 14.19 380 1025 5.36 / 705.30 2 17
Average= 5.00 (KJ/cycle)

Cycle 139 GMT 2/ 7/2018 20:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 33 14.19 528 247 0.25 / 694.89 2 3
2 7 2006.28 50 10.07 3218 1620 1.87 / 696.51 3 2
3 13 1830.44 33 12.19 2999 1206 3.07 / 697.72 2 2
4 13 1173.72 33 12.89 2074 882 3.96 / 698.60 2 3
5 13 226.56 33 13.96 727 335 4.29 / 698.94 2 3
6 14 -0.12 190 14.18 376 1013 5.30 / 699.95 2 10
Average= 5.00 (KJ/cycle)

Cycle 138 GMT 22/ 6/2018 20:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 33 14.19 543 254 0.25 / 689.75 2 3
2 3 972.72 -1 14.19 543 0 0.00 / 689.75 2 3
3 3 1035.64 1 12.44 1862 23 0.28 / 689.77 2 2
4 7 2003.36 50 10.24 3193 1635 1.91 / 691.41 2 2
5 13 1810.80 33 12.19 2990 1203 3.12 / 692.61 2 2
6 13 964.80 33 13.10 1778 769 3.88 / 693.38 2 3
7 13 71.80 33 14.20 496 232 4.12 / 693.61 2 3
8 14 0.04 190 14.17 383 1031 5.15 / 694.64 2 14
Average= 5.00 (KJ/cycle)

Cycle 137 GMT 12/ 6/2018 20:19:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 33 14.22 533 250 0.25 / 684.51 2 3
2 7 2004.72 50 10.12 3209 1624 1.87 / 686.13 3 2
3 13 1816.00 33 12.19 2980 1199 3.07 / 687.33 2 2
4 13 1155.12 33 12.90 2058 876 3.95 / 688.21 2 3
5 13 108.72 33 14.14 561 262 4.21 / 688.47 2 3
6 14 0.00 190 14.18 381 1026 5.24 / 689.50 2 12
Average= 5.00 (KJ/cycle)

Cycle 136 GMT 2/ 6/2018 20:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 33 14.23 526 247 0.25 / 679.26 2 3
2 7 2004.32 50 10.09 3221 1625 1.87 / 680.89 3 2
3 13 1826.40 33 12.16 3017 1211 3.08 / 682.10 2 2
4 13 1154.24 33 12.90 2057 876 3.96 / 682.97 2 3
5 13 108.04 33 14.13 561 262 4.22 / 683.24 2 3
6 14 0.12 190 14.19 380 1025 5.24 / 684.26 2 10
Average= 4.99 (KJ/cycle)

Cycle 135 GMT 23/ 5/2018 20:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 33 14.24 520 244 0.24 / 673.97 2 3
2 7 2002.56 50 10.16 3209 1630 1.87 / 675.60 3 2
3 13 1819.32 34 12.18 2995 1240 3.11 / 676.84 2 3
4 13 1143.28 34 12.91 2041 896 4.01 / 677.74 2 3
5 13 90.80 34 14.17 531 256 4.27 / 678.00 2 3
6 14 -0.20 190 14.20 378 1020 5.29 / 679.02 2 17
Average= 4.99 (KJ/cycle)

Cycle 134 GMT 13/ 5/2018 20:18: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 33 14.17 534 250 0.25 / 668.72 2 3
2 7 2004.84 50 10.20 3225 1645 1.89 / 670.37 3 2
3 13 1826.72 33 12.19 3004 1208 3.10 / 671.58 2 2
4 13 1155.28 33 12.90 2054 874 3.98 / 672.45 2 3
5 13 104.32 33 14.16 547 256 4.23 / 672.71 2 3
6 14 -0.04 190 14.20 379 1023 5.26 / 673.73 2 10
Average= 4.99 (KJ/cycle)

Cycle 133 GMT 3/ 5/2018 20:10: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 33 14.17 526 246 0.25 / 663.47 2 3
2 7 2002.08 50 10.30 3202 1649 1.89 / 665.12 3 2
3 13 1825.52 33 12.14 3016 1208 3.10 / 666.33 2 2
4 13 1146.56 33 12.91 2041 870 3.97 / 667.20 2 3
5 13 97.44 33 14.15 539 252 4.22 / 667.45 2 3
6 14 -0.04 190 14.17 380 1023 5.25 / 668.47 2 12
Average= 4.99 (KJ/cycle)

Cycle 132 GMT 23/ 4/2018 20:17: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 33 14.24 519 244 0.24 / 658.13 2 3
2 7 2007.72 51 10.28 3206 1681 1.92 / 659.81 3 2
3 13 1822.20 34 12.15 3009 1243 3.17 / 661.05 2 2
4 13 1152.68 34 12.89 2050 898 4.07 / 661.95 2 3
5 13 107.88 34 14.13 552 265 4.33 / 662.22 2 3
6 14 -0.08 190 14.17 375 1010 5.34 / 663.23 2 12
Average= 4.99 (KJ/cycle)

Cycle 131 GMT 13/ 4/2018 20:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 33 14.21 541 254 0.25 / 652.81 2 3
2 7 2009.88 51 10.31 3189 1677 1.93 / 654.49 3 2
3 13 1829.84 34 12.13 3031 1250 3.18 / 655.74 2 2
4 13 1167.68 34 12.89 2067 906 4.09 / 656.64 2 3
5 13 61.24 34 14.22 472 228 4.31 / 656.87 2 3
6 14 0.12 190 14.18 376 1013 5.33 / 657.89 2 10
Average= 4.98 (KJ/cycle)

Cycle 130 GMT 3/ 4/2018 20: 5: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 33 14.23 527 247 0.25 / 647.56 2 2
2 7 2003.24 50 10.17 3215 1635 1.88 / 649.19 2 2
3 13 1829.64 33 12.14 3015 1208 3.09 / 650.40 2 3
4 13 1159.92 33 12.89 2063 878 3.97 / 651.28 2 3
5 13 114.96 33 14.14 563 263 4.23 / 651.54 2 3
6 14 -0.08 190 14.19 378 1019 5.25 / 652.56 2 16
Average= 4.98 (KJ/cycle)

Cycle 129 GMT 24/ 3/2018 19:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 33 14.28 524 247 0.25 / 642.32 3 3
2 7 2007.44 50 10.09 3209 1619 1.87 / 643.94 3 2
3 13 1825.84 33 12.13 3024 1210 3.08 / 645.15 2 2
4 13 1158.48 33 12.90 2055 875 3.95 / 646.03 2 3
5 13 112.28 33 14.14 561 262 4.21 / 646.29 2 3
6 14 -0.08 190 14.20 377 1017 5.23 / 647.31 2 13
Average= 4.98 (KJ/cycle)

Cycle 128 GMT 14/ 3/2018 19:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 33 14.29 519 245 0.24 / 637.10 2 3
2 7 2009.44 50 10.14 3221 1633 1.88 / 638.73 3 2
3 13 1831.04 33 12.13 3014 1206 3.08 / 639.94 2 2
4 13 1165.84 33 12.90 2068 880 3.96 / 640.82 2 3
5 13 109.24 33 14.19 550 258 4.22 / 641.08 2 3
6 14 -0.12 190 14.25 370 1002 5.22 / 642.08 2 13
Average= 4.98 (KJ/cycle)

Cycle 127 GMT 4/ 3/2018 19:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 33 14.26 522 246 0.25 / 631.81 2 3
2 7 2010.84 50 10.10 3220 1626 1.87 / 633.43 2 2
3 13 1842.32 34 12.11 3047 1255 3.13 / 634.69 2 2
4 13 1170.24 34 12.88 2084 913 4.04 / 635.60 2 3
5 13 101.88 34 14.21 530 256 4.30 / 635.85 2 3
6 14 -0.04 190 14.25 369 999 5.29 / 636.85 2 10
Average= 4.98 (KJ/cycle)

Cycle 126 GMT 22/ 2/2018 19:53: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 33 14.29 522 246 0.25 / 626.73 2 3
2 7 2002.84 50 10.23 3177 1625 1.87 / 628.36 3 2
3 13 1824.84 33 12.15 3005 1205 3.08 / 629.56 2 2
4 13 988.36 33 13.07 1822 786 3.86 / 630.35 2 3
5 13 43.28 33 14.33 442 209 4.07 / 630.56 2 3
6 14 -0.04 190 14.25 371 1004 5.08 / 631.56 2 11
Average= 4.97 (KJ/cycle)

Cycle 125 GMT 12/ 2/2018 19:36: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 33 14.27 504 237 0.24 / 621.42 3 3
2 7 2001.12 51 10.25 3199 1672 1.91 / 623.09 3 2
3 13 1815.80 34 12.13 3000 1237 3.15 / 624.33 2 2
4 13 1151.16 34 12.89 2047 897 4.04 / 625.22 2 3
5 13 95.44 34 14.22 523 253 4.30 / 625.48 2 3
6 14 0.16 190 14.24 372 1006 5.30 / 626.48 2 11
Average= 4.97 (KJ/cycle)

Cycle 124 GMT 2/ 2/2018 19:41: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 33 14.28 520 245 0.25 / 616.23 3 3
2 7 2003.56 51 10.26 3194 1671 1.92 / 617.90 2 2
3 13 1826.96 34 12.14 3010 1242 3.16 / 619.14 2 3
4 13 984.00 34 13.08 1817 808 3.97 / 619.95 2 3
5 13 73.64 34 14.27 487 236 4.20 / 620.19 2 3
6 14 -0.16 190 14.24 368 996 5.20 / 621.18 2 10
Average= 4.97 (KJ/cycle)

Cycle 123 GMT 23/ 1/2018 19:31: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 33 14.27 516 243 0.24 / 610.98 3 3
2 7 2003.16 51 10.33 3187 1679 1.92 / 612.66 3 2
3 13 1827.40 33 12.15 2999 1202 3.12 / 613.86 2 2
4 13 1151.52 33 12.92 2040 870 3.99 / 614.73 2 3
5 13 99.60 33 14.22 524 246 4.24 / 614.98 2 3
6 14 -0.16 190 14.25 371 1004 5.24 / 615.98 2 9
Average= 4.97 (KJ/cycle)

Cycle 122 GMT 13/ 1/2018 19:27: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 33 14.30 516 244 0.24 / 605.80 3 3
2 7 2002.44 50 10.26 3227 1655 1.90 / 607.45 3 2
3 13 1820.64 33 12.17 2985 1199 3.10 / 608.65 2 2
4 13 1147.76 33 12.92 2042 871 3.97 / 609.52 2 3
5 13 56.80 33 14.31 462 218 4.19 / 609.74 2 3
6 14 -0.04 190 14.25 368 996 5.18 / 610.74 2 11
Average= 4.97 (KJ/cycle)

Cycle 121 GMT 3/ 1/2018 19:25: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 33 14.29 526 248 0.25 / 600.46 3 3
2 7 2006.00 51 10.44 3199 1703 1.95 / 602.17 2 2
3 13 1816.24 34 12.16 2984 1234 3.19 / 603.40 2 2
4 13 1155.36 34 12.91 2054 902 4.09 / 604.30 2 3
5 13 98.20 34 14.23 522 253 4.34 / 604.56 2 3
6 14 0.00 190 14.25 369 999 5.34 / 605.55 2 12
Average= 4.96 (KJ/cycle)

Cycle 120 GMT 24/12/2017 19:22: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 33 14.33 506 239 0.24 / 595.29 2 3
2 7 2004.92 50 10.45 3206 1675 1.91 / 596.96 2 2
3 13 1822.60 33 12.15 3000 1203 3.12 / 598.17 2 2
4 13 971.00 33 13.11 1794 776 3.89 / 598.94 2 3
5 13 122.84 33 14.17 566 265 4.16 / 599.21 2 3
6 14 -0.12 190 14.23 373 1008 5.17 / 600.22 2 12
Average= 4.96 (KJ/cycle)

Cycle 119 GMT 14/12/2017 19:17: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 33 14.30 506 239 0.24 / 590.05 3 3
2 7 2009.60 50 10.47 3231 1691 1.93 / 591.74 3 2
3 13 1825.12 33 12.15 3006 1205 3.14 / 592.95 2 2
4 13 1146.28 33 12.92 2035 868 4.00 / 593.81 2 3
5 13 93.64 33 14.23 518 243 4.25 / 594.06 2 3
6 14 -0.08 190 14.25 367 994 5.24 / 595.05 2 8
Average= 4.96 (KJ/cycle)

Cycle 118 GMT 4/12/2017 19:14: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 33 14.21 541 254 0.25 / 584.82 2 2
2 7 2001.44 51 10.63 3208 1739 1.99 / 586.56 2 2
3 13 1820.92 34 12.15 2999 1239 3.23 / 587.80 2 3
4 13 949.44 34 13.11 1762 785 4.02 / 588.59 2 3
5 13 51.76 34 14.26 459 223 4.24 / 588.81 2 3
6 14 -0.08 190 14.21 371 1002 5.24 / 589.81 2 11
Average= 4.96 (KJ/cycle)

Cycle 117 GMT 24/11/2017 19: 6: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 34 14.27 525 255 0.25 / 579.52 2 2
2 3 954.12 -1 14.27 525 0 0.00 / 579.52 2 2
3 3 1028.08 1 11.84 1858 22 0.28 / 579.54 2 2
4 7 2006.84 51 10.59 3207 1732 2.01 / 581.27 2 2
5 13 1819.88 34 12.16 2991 1237 3.25 / 582.51 2 2
6 13 968.12 34 13.08 1789 796 4.04 / 583.30 2 4
7 13 60.28 34 14.21 481 232 4.27 / 583.54 2 3
8 14 -0.08 190 14.12 385 1033 5.31 / 584.57 2 15
Average= 4.95 (KJ/cycle)

Cycle 116 GMT 14/11/2017 18:55: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 34 14.26 538 261 0.26 / 574.17 2 3
2 7 2004.04 51 10.51 3196 1713 1.97 / 575.89 3 2
3 13 1818.88 34 12.15 2995 1237 3.21 / 577.13 2 3
4 13 1140.20 34 12.92 2030 892 4.10 / 578.02 2 4
5 13 44.48 34 14.29 451 219 4.32 / 578.24 2 3
6 14 -0.08 190 14.18 381 1026 5.35 / 579.26 2 14
Average= 4.95 (KJ/cycle)

Cycle 115 GMT 4/11/2017 18:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 34 14.28 529 257 0.26 / 568.95 3 3
2 7 2001.00 50 10.42 3218 1677 1.93 / 570.62 3 2
3 13 1824.76 33 12.15 3020 1211 3.14 / 571.83 2 2
4 13 1144.36 33 12.92 2039 869 4.01 / 572.70 2 3
5 13 43.84 33 14.31 443 209 4.22 / 572.91 2 3
6 14 0.16 191 14.22 369 1002 5.23 / 573.91 2 12
Average= 4.95 (KJ/cycle)

Cycle 114 GMT 25/10/2017 18:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 34 14.27 509 247 0.25 / 563.76 3 3
2 7 2001.72 50 10.48 3190 1672 1.92 / 565.44 3 2
3 13 1816.76 33 12.16 2987 1199 3.12 / 566.63 2 2
4 13 1143.44 33 12.94 2030 867 3.98 / 567.50 2 3
5 13 44.24 33 14.33 435 206 4.19 / 567.71 2 3
6 14 0.04 190 14.24 363 982 5.17 / 568.69 2 14
Average= 4.95 (KJ/cycle)

Cycle 113 GMT 15/10/2017 16:47: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 32 14.26 519 237 0.24 / 558.72 3 3
2 3 1049.04 1 12.37 1871 23 0.26 / 558.74 2 2
3 3 1021.84 1 11.76 1836 22 0.28 / 558.76 2 2
4 7 2004.56 51 10.61 3184 1723 2.00 / 560.48 2 2
5 13 1823.52 34 12.17 2987 1236 3.24 / 561.72 2 2
6 13 970.20 34 13.12 1794 800 4.04 / 562.52 2 3
7 14 -0.20 190 14.23 369 998 5.04 / 563.52 2 9
Average= 4.94 (KJ/cycle)

Cycle 112 GMT 5/10/2017 15:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 33 14.29 524 247 0.25 / 553.75 3 3
2 3 919.88 -2 14.29 524 0 0.00 / 553.75 3 3
3 3 1058.28 2 12.45 1898 47 0.29 / 553.80 2 3
4 7 2001.80 50 10.78 3191 1720 2.01 / 555.52 3 2
5 13 1803.80 33 12.21 2976 1199 3.21 / 556.71 2 3
6 13 947.96 33 13.15 1762 765 3.98 / 557.48 2 3
7 14 0.04 190 14.22 370 1000 4.98 / 558.48 3 7
Average= 4.94 (KJ/cycle)

Cycle 111 GMT 25/ 9/2017 16: 3:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.80 33 14.23 539 253 0.25 / 548.53 2 3
2 7 2000.88 51 10.74 3215 1761 2.01 / 550.29 3 2
3 13 1817.92 33 12.19 3001 1207 3.22 / 551.50 2 2
4 13 948.72 33 13.13 1773 768 3.99 / 552.26 2 4
5 13 57.12 33 14.27 472 222 4.21 / 552.49 2 3
6 14 -0.04 190 14.20 376 1014 5.23 / 553.50 2 10
Average= 4.94 (KJ/cycle)

Cycle 110 GMT 15/ 9/2017 13:52:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 32 14.22 538 245 0.24 / 543.10 2 2
2 3 1037.00 1 12.37 1874 23 0.27 / 543.13 2 2
3 3 1022.88 1 12.04 1854 22 0.29 / 543.15 2 2
4 7 2002.88 51 10.81 3210 1770 2.06 / 544.92 2 2
5 13 1817.48 34 12.21 2985 1239 3.30 / 546.16 2 2
6 13 1115.24 33 12.96 1993 852 4.15 / 547.01 2 3
7 13 87.08 34 14.21 516 249 4.40 / 547.26 2 3
8 14 -0.16 190 14.16 377 1014 5.42 / 548.27 2 14
Average= 4.94 (KJ/cycle)

Cycle 109 GMT 5/ 9/2017 14: 0: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 32 14.19 524 238 0.24 / 538.16 2 3
2 7 2003.76 51 10.81 3221 1776 2.01 / 539.94 3 2
3 13 1633.40 33 12.39 2733 1117 3.13 / 541.05 2 3
4 13 980.96 33 13.09 1810 782 3.91 / 541.84 2 3
5 14 -0.08 190 14.14 381 1024 4.94 / 542.86 2 6
Average= 4.94 (KJ/cycle)

Cycle 108 GMT 26/ 8/2017 11:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 33 14.22 546 256 0.26 / 532.93 2 2
2 3 933.48 -1 14.22 546 0 0.00 / 532.93 2 2
3 7 2007.40 50 10.84 3232 1752 2.01 / 534.68 2 2
4 13 1819.16 34 12.19 3006 1246 3.25 / 535.93 2 2
5 13 924.20 34 13.14 1734 775 4.03 / 536.71 2 4
6 13 6.40 34 14.31 401 195 4.22 / 536.90 2 3
7 14 0.12 190 14.09 382 1023 5.25 / 537.92 2 13
Average= 4.94 (KJ/cycle)

Cycle 107 GMT 16/ 8/2017 11:59: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 32 14.22 532 242 0.24 / 527.70 2 3
2 7 2001.64 50 10.86 3213 1745 1.99 / 529.45 2 2
3 13 1810.04 33 12.20 3003 1209 3.20 / 530.66 2 2
4 13 921.76 33 13.16 1729 751 3.95 / 531.41 2 3
5 13 112.40 33 14.17 557 260 4.21 / 531.67 2 3
6 14 -0.08 190 14.18 374 1008 5.21 / 532.68 2 12
Average= 4.93 (KJ/cycle)

Cycle 106 GMT 6/ 8/2017 9:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 32 14.27 524 239 0.24 / 522.40 3 3
2 7 2006.44 50 10.92 3211 1753 1.99 / 524.15 2 2
3 13 1816.16 33 12.23 2979 1202 3.19 / 525.35 2 2
4 13 1116.00 33 12.97 1995 854 4.05 / 526.21 2 3
5 13 85.48 33 14.22 514 241 4.29 / 526.45 2 3
6 14 0.08 190 14.18 376 1013 5.30 / 527.46 2 9
Average= 4.93 (KJ/cycle)

Cycle 105 GMT 27/ 7/2017 7:44: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 33 14.31 504 238 0.24 / 517.25 3 3
2 3 963.32 -1 14.31 504 0 0.00 / 517.25 3 3
3 3 1028.36 1 11.59 1872 22 0.26 / 517.27 2 2
4 7 2007.16 50 10.98 3209 1762 2.02 / 519.03 2 2
5 13 1809.28 33 12.26 2966 1200 3.22 / 520.23 2 2
6 13 929.36 33 13.15 1738 754 3.98 / 520.99 2 3
7 13 13.20 33 14.35 398 188 4.16 / 521.18 2 3
8 14 -0.36 190 14.14 366 983 5.15 / 522.16 2 15
Average= 4.93 (KJ/cycle)

Cycle 104 GMT 17/ 7/2017 5:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 33 14.34 509 241 0.24 / 512.06 2 3
2 7 2004.64 50 10.99 3230 1775 2.02 / 513.83 3 2
3 13 1806.00 33 12.24 2955 1194 3.21 / 515.02 2 3
4 13 931.28 33 13.12 1746 756 3.97 / 515.78 2 3
5 13 48.72 33 14.25 459 216 4.18 / 516.00 2 3
6 14 -0.04 190 14.15 378 1016 5.20 / 517.01 2 11
Average= 4.92 (KJ/cycle)

Cycle 103 GMT 7/ 7/2017 5:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 33 14.33 527 249 0.25 / 506.79 2 3
2 7 2002.88 51 10.98 3229 1808 2.06 / 508.60 3 2
3 13 1802.72 34 12.26 2951 1230 3.29 / 509.83 2 2
4 13 917.92 34 13.15 1723 770 4.06 / 510.60 2 3
5 13 49.40 34 14.29 450 219 4.28 / 510.82 2 3
6 14 -0.20 190 14.20 369 996 5.27 / 511.81 2 14
Average= 4.92 (KJ/cycle)

Cycle 102 GMT 27/ 6/2017 5:16: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 33 14.35 517 245 0.24 / 501.51 2 3
2 7 2001.00 51 10.87 3218 1784 2.03 / 503.29 3 2
3 13 1822.08 34 12.22 3005 1249 3.28 / 504.54 2 2
4 13 933.72 34 13.14 1744 779 4.06 / 505.32 2 3
5 13 46.00 34 14.28 451 219 4.28 / 505.54 2 3
6 14 -0.08 190 14.17 373 1004 5.28 / 506.54 2 13
Average= 4.92 (KJ/cycle)

Cycle 101 GMT 17/ 6/2017 5:13: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 33 14.35 505 239 0.24 / 496.37 2 3
2 7 2006.36 50 10.88 3207 1745 1.98 / 498.12 3 2
3 13 1644.56 33 12.45 2742 1127 3.11 / 499.25 2 3
4 13 991.08 33 13.09 1832 791 3.90 / 500.04 2 3
5 13 55.88 33 14.29 467 220 4.12 / 500.26 2 3
6 14 -0.12 190 14.19 373 1006 5.13 / 501.26 2 11
Average= 4.91 (KJ/cycle)

Cycle 100 GMT 7/ 6/2017 4:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 33 14.33 528 250 0.25 / 491.25 2 3
2 7 2005.56 51 11.01 3209 1802 2.05 / 493.05 3 2
3 13 1629.80 33 12.47 2703 1112 3.16 / 494.16 2 2
4 13 967.28 33 13.13 1801 780 3.94 / 494.95 2 3
5 13 48.68 33 14.32 448 212 4.16 / 495.16 2 3
6 14 -0.08 190 14.22 362 978 5.13 / 496.14 2 17
Average= 4.91 (KJ/cycle)

Cycle 99 GMT 28/ 5/2017 4:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 32 14.37 507 233 0.23 / 486.24 3 3
2 7 2004.08 51 11.00 3180 1784 2.02 / 488.02 2 2
3 13 1806.52 34 12.30 2949 1233 3.25 / 489.26 2 3
4 13 922.04 33 13.17 1737 755 4.01 / 490.01 2 3
5 14 0.04 190 14.21 367 991 5.00 / 491.00 2 9
Average= 4.91 (KJ/cycle)

Cycle 98 GMT 18/ 5/2017 2:48: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 32 14.39 497 229 0.23 / 481.02 3 3
2 7 2009.92 50 10.92 3216 1756 1.98 / 482.78 2 2
3 13 1815.72 34 12.30 2967 1241 3.23 / 484.02 2 3
4 13 928.88 34 13.18 1745 782 4.01 / 484.80 2 4
5 13 41.00 34 14.33 434 211 4.22 / 485.01 2 3
6 14 -0.12 190 14.19 369 995 5.21 / 486.00 2 16
Average= 4.91 (KJ/cycle)

Cycle 97 GMT 8/ 5/2017 0:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 32 14.38 513 236 0.24 / 475.97 2 3
2 7 2006.76 50 11.13 3193 1777 2.01 / 477.74 2 2
3 13 1625.84 34 12.51 2725 1159 3.17 / 478.90 2 3
4 13 771.00 34 13.36 1516 689 3.86 / 479.59 2 3
5 13 25.28 34 14.35 415 202 4.06 / 479.79 2 3
6 14 -0.16 190 14.18 370 997 5.06 / 480.79 2 9
Average= 4.91 (KJ/cycle)

Cycle 96 GMT 28/ 4/2017 0:27: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 32 14.36 532 244 0.24 / 470.79 2 3
2 7 2003.36 50 10.99 3213 1766 2.01 / 472.56 2 2
3 13 1807.00 33 12.32 2977 1210 3.22 / 473.77 2 2
4 13 912.96 33 13.20 1731 754 3.97 / 474.52 2 4
5 13 44.24 33 14.31 449 212 4.19 / 474.73 2 3
6 14 0.00 190 14.18 370 997 5.18 / 475.73 2 11
Average= 4.90 (KJ/cycle)

Cycle 95 GMT 18/ 4/2017 0:30: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 32 14.35 526 242 0.24 / 465.64 2 3
2 7 2008.80 50 11.10 3221 1788 2.03 / 467.43 3 2
3 13 1626.00 33 12.52 2717 1123 3.15 / 468.55 2 3
4 13 959.36 33 13.17 1784 775 3.93 / 469.33 2 4
5 13 47.00 33 14.31 455 215 4.14 / 469.54 2 3
6 14 -0.20 190 14.17 373 1004 5.15 / 470.55 2 12
Average= 4.90 (KJ/cycle)

Cycle 94 GMT 8/ 4/2017 0:30: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 32 14.37 531 244 0.24 / 460.44 2 3
2 7 2008.76 50 11.09 3208 1779 2.02 / 462.22 3 2
3 13 1808.40 33 12.33 2978 1212 3.23 / 463.43 2 3
4 13 911.36 33 13.21 1716 748 3.98 / 464.18 2 3
5 13 41.68 33 14.32 443 209 4.19 / 464.39 2 3
6 14 -0.04 190 14.17 376 1012 5.20 / 465.40 2 12
Average= 4.90 (KJ/cycle)

Cycle 93 GMT 29/ 3/2017 0:23: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 32 14.43 499 230 0.23 / 455.33 3 3
2 7 2008.12 50 11.07 3214 1779 2.01 / 457.11 3 2
3 13 1636.52 34 12.53 2722 1160 3.17 / 458.27 2 3
4 13 787.20 34 13.34 1549 703 3.87 / 458.97 2 3
5 13 58.20 34 14.30 467 227 4.10 / 459.20 2 3
6 14 -0.04 190 14.19 371 1000 5.10 / 460.20 2 14
Average= 4.90 (KJ/cycle)

Cycle 92 GMT 18/ 3/2017 22:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 32 14.40 512 236 0.24 / 450.19 2 3
2 7 2006.96 50 11.21 3235 1813 2.05 / 452.01 3 2
3 13 1621.36 33 12.57 2705 1122 3.17 / 453.13 2 3
4 13 945.56 33 13.18 1763 767 3.94 / 453.90 2 4
5 13 44.64 33 14.34 441 209 4.15 / 454.11 2 3
6 14 0.04 190 14.20 368 993 5.14 / 455.10 2 16
Average= 4.89 (KJ/cycle)

Cycle 91 GMT 8/ 3/2017 21:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 32 14.40 521 240 0.24 / 444.98 2 3
2 7 2003.60 50 11.12 3220 1790 2.03 / 446.77 3 2
3 13 1806.12 33 12.39 2940 1202 3.23 / 447.97 2 3
4 13 900.20 33 13.22 1706 744 3.98 / 448.71 2 4
5 13 77.12 33 14.26 506 238 4.21 / 448.95 2 3
6 14 -0.12 190 14.17 374 1007 5.22 / 449.96 2 13
Average= 4.89 (KJ/cycle)

Cycle 90 GMT 26/ 2/2017 22: 1: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 32 14.40 516 238 0.24 / 439.73 2 3
2 7 2002.48 51 11.13 3205 1819 2.06 / 441.55 3 2
3 13 1625.40 34 12.56 2740 1170 3.23 / 442.72 2 3
4 13 948.88 34 13.20 1775 797 4.02 / 443.52 2 4
5 13 44.04 34 14.32 446 217 4.24 / 443.74 2 3
6 14 -0.16 190 14.17 372 1002 5.24 / 444.74 2 16
Average= 4.89 (KJ/cycle)

Cycle 89 GMT 16/ 2/2017 21:44: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 32 14.41 516 238 0.24 / 434.54 3 3
2 7 2006.48 50 11.17 3207 1791 2.03 / 436.33 3 2
3 13 1624.28 34 12.57 2725 1165 3.19 / 437.49 2 3
4 13 940.20 34 13.21 1758 790 3.98 / 438.28 2 3
5 13 37.60 34 14.33 440 214 4.20 / 438.50 2 3
6 14 0.00 190 14.17 370 996 5.19 / 439.49 2 13
Average= 4.88 (KJ/cycle)

Cycle 88 GMT 6/ 2/2017 19:43: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 32 14.46 497 230 0.23 / 429.34 3 3
2 7 2008.20 50 11.08 3210 1778 2.01 / 431.12 3 2
3 13 1809.52 33 12.41 2960 1212 3.22 / 432.33 2 2
4 13 902.84 33 13.25 1712 749 3.97 / 433.08 2 4
5 13 39.36 33 14.32 446 211 4.18 / 433.29 2 3
6 14 -0.12 190 14.15 376 1011 5.19 / 434.30 2 13
Average= 4.88 (KJ/cycle)

Cycle 87 GMT 27/ 1/2017 17:35: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 32 14.44 513 237 0.24 / 424.31 2 3
2 7 2001.96 50 11.10 3205 1779 2.02 / 426.09 3 2
3 13 1618.88 33 12.61 2705 1126 3.14 / 427.22 2 3
4 13 777.56 33 13.41 1534 679 3.82 / 427.90 2 3
5 13 26.56 33 14.35 424 201 4.02 / 428.10 2 4
6 14 -0.12 190 14.14 377 1013 5.03 / 429.11 2 15
Average= 4.88 (KJ/cycle)

Cycle 86 GMT 17/ 1/2017 15:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 32 14.34 543 249 0.25 / 419.12 2 2
2 7 2008.76 50 11.12 3206 1783 2.03 / 420.90 2 2
3 13 1629.88 33 12.61 2741 1141 3.17 / 422.05 2 3
4 13 956.28 33 13.23 1789 781 3.95 / 422.83 2 3
5 13 41.92 33 14.31 457 216 4.17 / 423.04 2 3
6 14 -0.04 191 14.13 383 1034 5.20 / 424.08 2 14
Average= 4.87 (KJ/cycle)

Cycle 85 GMT 7/ 1/2017 15: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 32 14.37 537 247 0.25 / 413.89 2 2
2 7 2005.76 50 11.17 3203 1789 2.04 / 415.68 2 2
3 13 1624.52 34 12.66 2708 1166 3.20 / 416.84 2 3
4 13 947.32 34 13.26 1765 796 4.00 / 417.64 2 4
5 13 36.68 34 14.32 447 218 4.21 / 417.86 2 4
6 14 -0.08 190 14.13 379 1018 5.23 / 418.87 2 16
Average= 4.87 (KJ/cycle)

Cycle 84 GMT 28/12/2016 14:56: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 32 14.38 525 242 0.24 / 408.66 2 2
2 7 2003.00 50 11.11 3207 1781 2.02 / 410.44 2 2
3 13 1803.32 33 12.48 2954 1217 3.24 / 411.65 2 2
4 13 905.08 33 13.30 1715 753 3.99 / 412.41 2 3
5 13 41.32 33 14.33 452 214 4.21 / 412.62 2 3
6 14 -0.16 190 14.13 380 1020 5.23 / 413.64 2 20
Average= 4.87 (KJ/cycle)

Cycle 83 GMT 18/12/2016 14:46: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 32 14.40 544 251 0.25 / 403.44 2 2
2 7 2008.80 50 11.05 3184 1759 2.01 / 405.20 2 2
3 13 1818.04 33 12.46 2986 1228 3.24 / 406.43 2 3
4 13 930.24 33 13.29 1745 765 4.00 / 407.20 2 4
5 13 23.72 33 14.36 423 200 4.20 / 407.40 2 3
6 14 -0.16 191 14.13 377 1017 5.22 / 408.41 2 14
Average= 4.86 (KJ/cycle)

Cycle 82 GMT 8/12/2016 12:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 32 14.42 522 241 0.24 / 398.28 2 2
2 7 2002.36 50 11.06 3200 1770 2.01 / 400.05 2 2
3 13 1634.96 33 12.67 2725 1139 3.15 / 401.19 2 3
4 13 965.80 33 13.27 1799 788 3.94 / 401.98 2 3
5 13 21.20 33 14.35 425 201 4.14 / 402.18 2 3
6 14 0.00 190 14.12 379 1017 5.16 / 403.19 2 18
Average= 4.86 (KJ/cycle)

Cycle 81 GMT 28/11/2016 12:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 32 14.40 530 244 0.24 / 393.00 2 2
2 7 2001.68 51 11.08 3201 1809 2.05 / 394.81 2 2
3 13 1628.92 34 12.69 2720 1174 3.23 / 395.99 2 3
4 13 964.12 34 13.28 1805 815 4.04 / 396.80 2 3
5 13 42.88 34 14.34 456 222 4.26 / 397.02 2 4
6 14 -0.12 190 14.15 377 1014 5.28 / 398.04 2 14
Average= 4.85 (KJ/cycle)

Cycle 80 GMT 18/11/2016 12:37: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 32 14.35 531 244 0.24 / 387.84 2 2
2 7 2007.04 50 11.21 3189 1787 2.03 / 389.63 2 2
3 13 1627.44 33 12.70 2725 1142 3.17 / 390.77 2 3
4 13 955.84 33 13.31 1789 786 3.96 / 391.56 2 3
5 13 4.68 33 14.41 392 186 4.15 / 391.74 2 3
6 14 0.04 190 14.14 379 1018 5.16 / 392.76 2 17
Average= 4.85 (KJ/cycle)

Cycle 79 GMT 8/11/2016 12:30: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 32 14.40 538 248 0.25 / 382.70 2 2
2 7 2007.36 51 11.13 3218 1827 2.07 / 384.53 2 2
3 13 1807.88 34 12.52 2978 1268 3.34 / 385.80 2 2
4 13 903.84 34 13.35 1718 780 4.12 / 386.58 2 3
5 14 -0.12 190 14.20 378 1020 5.14 / 387.60 2 10
Average= 4.84 (KJ/cycle)

Cycle 78 GMT 29/10/2016 12:25: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 32 14.41 537 248 0.25 / 377.65 2 2
2 7 2005.00 50 11.09 3224 1788 2.04 / 379.43 2 2
3 13 1804.92 33 12.53 2957 1223 3.26 / 380.66 2 3
4 13 914.48 33 13.35 1730 762 4.02 / 381.42 2 4
5 14 -0.04 190 14.19 384 1035 5.06 / 382.46 2 11
Average= 4.84 (KJ/cycle)

Cycle 77 GMT 19/10/2016 12:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 32 14.41 554 255 0.26 / 372.58 2 2
2 7 2001.76 51 11.23 3194 1829 2.08 / 374.41 2 2
3 13 1614.88 34 12.75 2704 1172 3.26 / 375.58 2 3
4 13 936.92 34 13.36 1757 798 4.06 / 376.38 2 3
5 14 -0.16 190 14.21 377 1018 5.07 / 377.40 2 6
Average= 4.84 (KJ/cycle)

Cycle 76 GMT 9/10/2016 12:30:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 31 14.48 520 233 0.23 / 367.47 2 3
2 7 2007.76 50 11.21 3241 1817 2.05 / 369.29 2 2
3 13 1815.00 33 12.55 2986 1237 3.29 / 370.52 2 2
4 13 923.28 33 13.36 1751 772 4.06 / 371.30 2 3
5 14 0.00 190 14.20 382 1031 5.09 / 372.33 2 8
Average= 4.84 (KJ/cycle)

Cycle 75 GMT 29/ 9/2016 10:34:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 31 14.46 535 240 0.24 / 362.59 2 2
2 7 2007.24 50 11.20 3237 1813 2.05 / 364.40 2 2
3 13 1613.24 33 12.75 2709 1140 3.19 / 365.54 2 3
4 13 774.44 33 13.54 1516 677 3.87 / 366.22 2 3
5 14 0.00 190 14.22 376 1016 4.89 / 367.24 2 12
Average= 4.83 (KJ/cycle)

Cycle 74 GMT 19/ 9/2016 8:22: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 31 14.50 522 235 0.23 / 357.53 2 3
2 7 2003.72 50 11.33 3231 1830 2.07 / 359.36 2 2
3 13 1610.48 33 12.78 2696 1137 3.20 / 360.49 2 3
4 13 760.48 33 13.56 1497 670 3.87 / 361.16 2 3
5 13 5.92 33 14.42 393 187 4.06 / 361.35 2 4
6 14 -0.12 190 14.15 372 1000 5.06 / 362.35 2 17
Average= 4.83 (KJ/cycle)

Cycle 73 GMT 9/ 9/2016 5:53: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 31 14.51 521 234 0.23 / 352.45 2 3
2 7 2000.88 50 11.35 3253 1846 2.08 / 354.29 3 2
3 13 1614.40 33 12.79 2719 1148 3.23 / 355.44 2 3
4 13 754.00 33 13.56 1508 675 3.90 / 356.11 2 3
5 13 8.52 33 14.45 388 185 4.09 / 356.30 2 3
6 14 0.00 190 14.17 369 993 5.08 / 357.29 2 14
Average= 4.83 (KJ/cycle)

Cycle 72 GMT 30/ 8/2016 3:42: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 31 14.52 529 238 0.24 / 347.36 2 3
2 7 2001.12 50 11.42 3234 1847 2.08 / 349.20 3 2
3 13 1804.80 33 12.61 2953 1229 3.31 / 350.43 2 2
4 13 892.08 33 13.41 1696 751 4.06 / 351.18 2 3
5 14 -0.08 190 14.20 381 1028 5.09 / 352.21 2 7
Average= 4.82 (KJ/cycle)

Cycle 71 GMT 20/ 8/2016 1:40: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 31 14.46 520 233 0.23 / 342.46 2 3
2 7 2003.04 50 11.41 3210 1831 2.06 / 344.30 2 2
3 13 1611.68 33 12.83 2696 1141 3.21 / 345.44 2 2
4 13 746.28 33 13.57 1482 664 3.87 / 346.10 2 3
5 14 -0.12 190 14.22 377 1019 4.89 / 347.12 2 9
Average= 4.82 (KJ/cycle)

Cycle 70 GMT 10/ 8/2016 1:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 31 14.56 521 235 0.24 / 337.73 2 3
2 7 1820.00 30 11.71 2989 1050 1.29 / 338.78 3 2
3 13 1717.24 20 12.93 2865 741 2.03 / 339.52 2 2
4 13 1530.20 20 13.12 2589 679 2.71 / 340.20 2 3
5 13 1091.52 20 13.45 1980 533 3.24 / 340.73 2 3
6 13 629.80 20 13.82 1329 367 3.61 / 341.10 2 3
7 13 27.36 20 14.44 422 122 3.73 / 341.22 2 3
8 14 0.16 190 14.21 375 1012 4.74 / 342.23 2 16
Average= 4.82 (KJ/cycle)

Cycle 69 GMT 30/ 7/2016 22:49: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 31 14.49 522 234 0.23 / 333.13 2 3
2 7 1820.24 30 11.83 2984 1059 1.29 / 334.19 3 2
3 13 1681.28 20 12.97 2814 730 2.02 / 334.92 2 3
4 13 1503.40 20 13.16 2560 674 2.70 / 335.59 2 3
5 13 1068.80 20 13.47 1948 525 3.22 / 336.11 2 3
6 13 607.16 20 13.83 1292 357 3.58 / 336.47 2 3
7 14 -0.08 190 14.23 377 1019 4.60 / 337.49 2 9
Average= 4.82 (KJ/cycle)

Cycle 68 GMT 20/ 7/2016 20:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 31 14.49 525 236 0.24 / 328.32 2 2
2 7 2001.80 30 11.79 3221 1139 1.38 / 329.46 2 2
3 13 1851.48 20 12.91 3052 788 2.16 / 330.25 2 3
4 13 1644.96 20 13.09 2757 722 2.88 / 330.97 2 3
5 13 1194.88 20 13.41 2124 570 3.45 / 331.54 2 3
6 13 535.16 20 13.92 1185 330 3.78 / 331.87 2 3
7 14 -0.12 190 14.24 379 1025 4.81 / 332.89 2 8
Average= 4.82 (KJ/cycle)

Cycle 67 GMT 10/ 7/2016 20:23: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 31 14.56 521 235 0.24 / 323.33 2 3
2 7 2003.76 30 11.85 3233 1149 1.38 / 324.48 2 2
3 13 1858.04 20 12.92 3064 792 2.18 / 325.27 2 2
4 13 1664.48 20 13.10 2786 730 2.91 / 326.00 2 3
5 13 1216.16 20 13.42 2155 578 3.48 / 326.58 2 3
6 13 548.04 20 13.93 1208 337 3.82 / 326.92 2 3
7 13 75.36 20 14.39 505 145 3.97 / 327.06 2 3
8 14 -0.16 190 14.24 377 1020 4.99 / 328.08 2 12
Average= 4.82 (KJ/cycle)

Cycle 66 GMT 30/ 6/2016 17:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 31 14.50 531 239 0.24 / 318.54 2 2
2 7 2003.04 30 11.96 3220 1155 1.39 / 319.70 2 2
3 13 1849.72 20 12.95 3024 783 2.18 / 320.48 2 2
4 13 1657.72 20 13.13 2785 731 2.91 / 321.21 2 3
5 13 1021.68 20 13.56 1876 509 3.42 / 321.72 2 3
6 13 587.04 20 13.92 1259 351 3.77 / 322.07 2 3
7 14 0.08 190 14.24 378 1023 4.79 / 323.10 2 10
Average= 4.82 (KJ/cycle)

Cycle 65 GMT 20/ 6/2016 17:32: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 31 14.58 526 238 0.24 / 313.70 2 3
2 7 2003.96 30 12.04 3220 1163 1.40 / 314.87 2 2
3 13 1847.52 20 12.96 3039 788 2.19 / 315.65 2 2
4 13 1639.92 20 13.14 2766 727 2.92 / 316.38 2 3
5 13 1188.88 20 13.45 2125 572 3.49 / 316.95 2 3
6 13 506.16 20 13.99 1146 321 3.81 / 317.27 2 3
7 14 -0.28 190 14.24 382 1034 4.84 / 318.31 2 10
Average= 4.82 (KJ/cycle)

Cycle 64 GMT 10/ 6/2016 15:13: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 31 14.54 512 231 0.23 / 308.78 2 2
2 7 2001.16 30 12.07 3224 1167 1.40 / 309.95 2 2
3 13 1843.00 21 12.98 3045 830 2.23 / 310.78 2 2
4 13 1642.04 21 13.16 2758 762 2.99 / 311.54 2 3
5 13 1182.80 20 13.48 2112 569 3.56 / 312.11 2 3
6 13 504.32 20 14.00 1145 321 3.88 / 312.43 2 3
7 14 0.04 190 14.25 381 1032 4.91 / 313.46 2 8
Average= 4.82 (KJ/cycle)

Cycle 63 GMT 31/ 5/2016 14:55: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 31 14.55 517 233 0.23 / 303.86 2 3
2 7 2006.32 30 12.16 3247 1185 1.42 / 305.05 3 2
3 13 1847.64 20 12.99 3034 788 2.21 / 305.83 2 2
4 13 1640.56 20 13.18 2731 720 2.93 / 306.55 2 3
5 13 1192.52 20 13.48 2130 574 3.50 / 307.13 2 3
6 13 727.36 20 13.81 1466 405 3.90 / 307.53 2 3
7 14 0.20 190 14.27 376 1019 4.92 / 308.55 2 8
Average= 4.82 (KJ/cycle)

Cycle 62 GMT 21/ 5/2016 14:47: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 31 14.64 510 231 0.23 / 298.93 3 3
2 7 2002.20 30 12.19 3240 1185 1.42 / 300.12 3 2
3 13 1852.28 20 12.99 3051 793 2.21 / 300.91 2 2
4 13 1648.16 20 13.18 2769 730 2.94 / 301.64 2 2
5 13 1002.00 20 13.61 1849 503 3.44 / 302.14 2 3
6 13 563.16 20 13.95 1228 343 3.78 / 302.49 2 3
7 13 37.88 20 14.46 443 128 3.91 / 302.61 2 3
8 14 -0.32 190 14.24 375 1015 4.93 / 303.63 2 13
Average= 4.82 (KJ/cycle)

Cycle 61 GMT 11/ 5/2016 12:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 31 14.64 517 235 0.23 / 293.99 3 3
2 7 2001.88 30 12.29 3219 1187 1.42 / 295.18 2 2
3 13 1843.20 20 13.04 3015 786 2.21 / 295.97 2 2
4 13 1636.32 20 13.22 2744 726 2.93 / 296.69 2 3
5 13 1179.20 20 13.52 2095 566 3.50 / 297.26 2 3
6 13 494.96 20 14.03 1127 316 3.82 / 297.57 2 3
7 13 13.48 20 14.50 402 117 3.93 / 297.69 2 3
8 14 -0.04 190 14.25 373 1010 4.94 / 298.70 2 13
Average= 4.82 (KJ/cycle)

Cycle 60 GMT 1/ 5/2016 9:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 31 14.67 492 224 0.22 / 289.00 3 3
2 7 2004.32 30 12.33 3229 1194 1.42 / 290.19 3 2
3 13 1850.48 20 13.03 3051 795 2.21 / 290.99 2 2
4 13 1643.24 20 13.23 2751 728 2.94 / 291.72 2 3
5 13 1181.40 20 13.53 2103 569 3.51 / 292.28 2 3
6 13 496.16 20 14.04 1134 318 3.83 / 292.60 2 3
7 13 53.96 20 14.46 476 138 3.97 / 292.74 2 3
8 14 -0.20 190 14.28 375 1017 4.98 / 293.76 2 11
Average= 4.82 (KJ/cycle)

Cycle 59 GMT 21/ 4/2016 7:49: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 31 14.67 502 228 0.23 / 284.01 3 3
2 7 2002.40 30 12.40 3214 1196 1.42 / 285.21 2 2
3 13 1848.76 20 13.06 3055 798 2.22 / 286.01 2 2
4 13 1640.88 20 13.23 2762 731 2.95 / 286.74 2 3
5 13 1181.52 20 13.52 2114 572 3.52 / 287.31 2 3
6 13 500.08 20 14.05 1134 319 3.84 / 287.63 2 3
7 13 53.20 20 14.47 468 135 3.98 / 287.76 2 3
8 14 -0.08 190 14.26 373 1011 4.99 / 288.77 2 11
Average= 4.81 (KJ/cycle)

Cycle 58 GMT 11/ 4/2016 5:38: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 31 14.61 507 230 0.23 / 278.90 2 3
2 7 2003.92 30 12.44 3246 1211 1.44 / 280.11 3 2
3 13 1838.36 21 13.07 3019 829 2.27 / 280.94 2 3
4 13 1640.20 21 13.25 2750 765 3.03 / 281.70 2 3
5 13 1180.00 21 13.54 2111 600 3.64 / 282.30 2 3
6 13 495.84 21 14.06 1131 334 3.97 / 282.64 2 3
7 13 53.76 21 14.48 464 141 4.11 / 282.78 2 3
8 14 0.00 190 14.30 371 1008 5.12 / 283.79 2 13
Average= 4.81 (KJ/cycle)

Cycle 57 GMT 1/ 4/2016 5:24: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 31 14.69 497 226 0.23 / 273.93 3 3
2 7 2002.84 30 12.49 3226 1209 1.44 / 275.14 2 2
3 13 1844.48 20 13.08 3015 789 2.22 / 275.93 2 2
4 13 1635.76 20 13.26 2744 728 2.95 / 276.65 2 3
5 13 1172.16 20 13.56 2090 567 3.52 / 277.22 2 3
6 13 485.96 20 14.08 1106 311 3.83 / 277.53 2 3
7 13 51.96 20 14.48 460 133 3.96 / 277.66 2 3
8 14 0.00 190 14.31 369 1003 4.97 / 278.67 2 14
Average= 4.80 (KJ/cycle)

Cycle 56 GMT 22/ 3/2016 3: 8: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 31 14.62 518 235 0.23 / 268.91 3 3
2 7 2003.68 30 12.40 3218 1197 1.43 / 270.11 3 2
3 13 1852.96 21 13.05 3058 838 2.27 / 270.95 2 2
4 13 1648.92 21 13.23 2765 768 3.04 / 271.71 2 3
5 13 1001.80 20 13.66 1844 504 3.54 / 272.22 2 3
6 13 550.24 20 14.03 1206 338 3.88 / 272.56 2 3
7 13 31.96 20 14.50 441 128 4.01 / 272.68 2 3
8 14 -0.12 190 14.27 375 1017 5.02 / 273.70 2 18
Average= 4.80 (KJ/cycle)

Cycle 55 GMT 12/ 3/2016 2:46: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 31 14.62 519 235 0.24 / 263.92 3 3
2 7 2004.68 30 12.35 3229 1196 1.43 / 265.12 3 2
3 13 1853.80 20 13.04 3042 793 2.22 / 265.91 2 2
4 13 1647.00 20 13.22 2774 733 2.96 / 266.64 2 3
5 13 1189.72 20 13.53 2121 574 3.53 / 267.22 2 3
6 13 499.88 20 14.07 1135 319 3.85 / 267.54 2 3
7 13 51.76 20 14.49 466 135 3.99 / 267.67 2 3
8 14 -0.12 190 14.31 369 1003 4.99 / 268.68 2 13
Average= 4.80 (KJ/cycle)

Cycle 54 GMT 2/ 3/2016 2:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 31 14.70 503 229 0.23 / 258.93 3 3
2 7 2001.28 30 12.30 3237 1194 1.42 / 260.13 3 2
3 13 1839.28 20 13.02 3032 790 2.21 / 260.92 2 2
4 13 1629.88 20 13.22 2738 724 2.94 / 261.64 2 3
5 13 1181.24 20 13.53 2108 570 3.51 / 262.21 2 3
6 13 495.96 20 14.07 1133 319 3.83 / 262.53 2 3
7 13 52.44 20 14.49 474 137 3.96 / 262.67 2 3
8 14 -0.04 190 14.30 375 1019 4.98 / 263.69 2 13
Average= 4.79 (KJ/cycle)

Cycle 53 GMT 21/ 2/2016 0:15: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 31 14.68 519 236 0.24 / 253.96 3 3
2 7 2001.84 30 12.32 3213 1188 1.42 / 255.15 3 2
3 13 1850.56 20 13.00 3035 789 2.21 / 255.94 2 2
4 13 1650.48 20 13.20 2774 732 2.95 / 256.67 2 3
5 13 1189.36 20 13.53 2115 572 3.52 / 257.24 2 3
6 13 505.84 20 14.07 1145 322 3.84 / 257.56 2 3
7 13 27.68 20 14.52 429 125 3.96 / 257.69 2 3
8 14 -0.12 190 14.29 374 1015 4.98 / 258.70 2 13
Average= 4.79 (KJ/cycle)

Cycle 52 GMT 10/ 2/2016 21:52: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 30 14.68 497 219 0.22 / 248.98 3 3
2 7 2002.68 30 12.30 3236 1194 1.41 / 250.17 2 2
3 13 1847.92 20 13.01 3030 788 2.20 / 250.96 2 2
4 13 1642.04 20 13.19 2764 729 2.93 / 251.69 2 3
5 13 1185.48 20 13.53 2113 572 3.50 / 252.26 2 3
6 13 502.28 20 14.08 1140 321 3.82 / 252.58 2 3
7 13 27.08 20 14.53 429 125 3.95 / 252.71 2 3
8 14 0.20 190 14.29 375 1018 4.97 / 253.72 2 14
Average= 4.79 (KJ/cycle)

Cycle 51 GMT 31/ 1/2016 19:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 30 14.64 518 228 0.23 / 244.02 2 3
2 7 2002.16 30 12.37 3210 1191 1.42 / 245.21 3 2
3 13 1837.56 20 13.03 3025 788 2.21 / 246.00 2 2
4 13 1640.60 20 13.21 2750 727 2.93 / 246.72 2 3
5 13 1191.28 20 13.53 2128 576 3.51 / 247.30 2 3
6 13 501.48 20 14.09 1137 320 3.83 / 247.62 2 3
7 13 27.12 20 14.55 427 124 3.95 / 247.74 2 3
8 14 -0.20 190 14.31 373 1014 4.97 / 248.76 2 11
Average= 4.78 (KJ/cycle)

Cycle 50 GMT 21/ 1/2016 19:26: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 31 14.74 506 231 0.23 / 239.06 3 3
2 3 968.12 -1 14.74 506 0 0.00 / 239.06 3 3
3 3 1037.04 1 13.57 1905 26 0.26 / 239.09 2 2
4 7 2001.28 30 12.39 3217 1196 1.45 / 240.29 2 2
5 13 1837.48 20 13.03 2989 779 2.23 / 241.06 2 2
6 13 1629.36 20 13.21 2734 722 2.95 / 241.79 2 3
7 13 1173.84 20 13.55 2086 565 3.52 / 242.35 2 4
8 13 490.52 20 14.10 1115 314 3.83 / 242.67 2 3
9 13 26.52 20 14.54 423 123 3.96 / 242.79 2 3
10 14 0.00 190 14.30 368 1000 4.96 / 243.79 2 14
Average= 4.78 (KJ/cycle)

Cycle 49 GMT 11/ 1/2016 18:22: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 31 14.65 516 234 0.23 / 234.16 2 3
2 7 2002.88 30 12.47 3215 1203 1.44 / 235.36 3 2
3 13 1850.40 20 13.05 3044 794 2.23 / 236.15 2 3
4 13 1638.44 20 13.23 2737 724 2.96 / 236.88 2 3
5 13 970.60 20 13.71 1806 495 3.45 / 237.37 2 3
6 13 524.36 20 14.09 1171 330 3.78 / 237.70 2 3
7 13 27.52 20 14.56 422 123 3.90 / 237.83 2 3
8 14 -0.16 190 14.31 370 1006 4.91 / 238.83 2 15
Average= 4.78 (KJ/cycle)

Cycle 48 GMT 1/ 1/2016 18: 5: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 31 14.62 521 236 0.24 / 229.22 2 3
2 7 2007.12 30 12.50 3247 1218 1.45 / 230.43 3 2
3 13 1846.24 20 13.07 3044 796 2.25 / 231.23 2 2
4 13 1633.88 20 13.25 2759 731 2.98 / 231.96 2 3
5 13 975.84 20 13.71 1819 499 3.48 / 232.46 2 4
6 13 521.16 20 14.10 1165 329 3.81 / 232.79 2 3
7 13 27.88 20 14.56 433 126 3.93 / 232.91 2 3
8 14 -0.04 190 14.31 371 1009 4.94 / 233.92 2 17
Average= 4.77 (KJ/cycle)

Cycle 47 GMT 22/12/2015 17:38: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 31 14.65 527 239 0.24 / 224.37 2 3
2 7 2002.80 30 12.58 3242 1224 1.46 / 225.60 3 2
3 13 1844.68 20 13.08 3057 800 2.26 / 226.39 2 2
4 13 1637.96 20 13.27 2763 733 3.00 / 227.13 2 3
5 13 975.76 20 13.74 1810 497 3.49 / 227.63 2 3
6 13 521.12 20 14.11 1168 330 3.82 / 227.96 2 3
7 14 0.08 190 14.35 376 1025 4.85 / 228.98 2 11
Average= 4.77 (KJ/cycle)

Cycle 46 GMT 12/12/2015 17:23: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 31 14.63 527 239 0.24 / 219.53 2 3
2 7 2003.24 30 12.65 3229 1225 1.46 / 220.76 3 2
3 13 1843.56 20 13.12 3030 795 2.26 / 221.55 2 2
4 13 1631.00 20 13.31 2746 731 2.99 / 222.28 2 3
5 13 968.60 20 13.75 1809 497 3.49 / 222.78 2 3
6 13 511.60 20 14.15 1157 327 3.82 / 223.11 2 3
7 14 -0.12 190 14.36 375 1023 4.84 / 224.13 2 10
Average= 4.77 (KJ/cycle)

Cycle 45 GMT 2/12/2015 17: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 31 14.66 511 232 0.23 / 214.59 2 3
2 7 2001.60 30 12.73 3220 1230 1.46 / 215.82 3 2
3 13 1836.88 20 13.17 3003 791 2.25 / 216.61 2 2
4 13 1623.16 20 13.34 2724 727 2.98 / 217.34 2 3
5 13 962.40 20 13.79 1788 493 3.47 / 217.83 2 3
6 13 500.28 20 14.17 1133 321 3.79 / 218.15 2 3
7 13 9.52 20 14.61 402 117 3.91 / 218.27 2 4
8 14 0.00 190 14.32 377 1026 4.94 / 219.29 2 17
Average= 4.77 (KJ/cycle)

Cycle 44 GMT 22/11/2015 16:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 31 14.65 525 238 0.24 / 209.79 2 3
2 7 2001.80 31 12.78 3217 1275 1.51 / 211.07 2 2
3 13 1825.68 20 13.22 2993 791 2.30 / 211.86 2 2
4 13 1610.76 20 13.37 2719 727 3.03 / 212.59 2 3
5 13 936.72 21 13.82 1756 510 3.54 / 213.10 2 3
6 13 272.40 21 14.38 804 243 3.78 / 213.34 2 3
7 14 0.00 190 14.38 372 1016 4.80 / 214.36 2 15
Average= 4.76 (KJ/cycle)

Cycle 43 GMT 12/11/2015 16:39:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 31 14.59 540 244 0.24 / 204.89 2 2
2 7 2005.76 30 12.85 3216 1240 1.48 / 206.13 2 2
3 13 1844.00 20 13.22 2988 790 2.27 / 206.92 2 3
4 13 1625.36 20 13.37 2737 732 3.01 / 207.65 2 3
5 13 1161.16 20 13.68 2078 569 3.57 / 208.22 2 3
6 13 472.28 20 14.22 1096 312 3.89 / 208.53 2 3
7 14 0.04 190 14.37 376 1027 4.91 / 209.56 2 12
Average= 4.76 (KJ/cycle)

Cycle 42 GMT 2/11/2015 16:46: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 31 14.60 535 242 0.24 / 200.03 2 3
2 7 2002.68 30 12.89 3215 1243 1.49 / 201.27 3 2
3 13 1829.80 20 13.24 3016 799 2.28 / 202.07 2 2
4 13 1610.84 20 13.40 2701 724 3.01 / 202.80 2 3
5 13 950.12 20 13.84 1767 489 3.50 / 203.28 2 3
6 13 490.48 20 14.22 1120 319 3.82 / 203.60 2 3
7 14 -0.08 190 14.37 381 1040 4.86 / 204.64 2 10
Average= 4.76 (KJ/cycle)

Cycle 41 GMT 23/10/2015 16:46: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 31 14.60 532 241 0.24 / 195.16 2 3
2 7 2005.84 30 12.91 3237 1254 1.49 / 196.41 3 2
3 13 1833.56 20 13.24 3035 804 2.30 / 197.22 2 2
4 13 1622.16 20 13.41 2698 724 3.02 / 197.94 2 3
5 13 954.56 20 13.85 1774 491 3.51 / 198.43 2 3
6 13 497.24 20 14.22 1126 320 3.83 / 198.75 2 3
7 14 0.08 190 14.37 380 1038 4.87 / 199.79 2 12
Average= 4.76 (KJ/cycle)

Cycle 40 GMT 13/10/2015 16:55:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 31 14.61 547 248 0.25 / 190.36 2 2
2 7 2001.84 30 12.96 3199 1244 1.49 / 191.60 2 2
3 13 1832.36 20 13.26 2991 793 2.28 / 192.39 2 2
4 13 1418.68 20 13.54 2432 659 2.94 / 193.05 2 3
5 13 979.60 20 13.84 1810 501 3.44 / 193.55 2 3
6 13 519.40 20 14.21 1163 331 3.77 / 193.88 2 3
7 14 -0.12 190 14.37 379 1035 4.81 / 194.92 2 10
Average= 4.75 (KJ/cycle)

Cycle 39 GMT 3/10/2015 16:52:59

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 30 14.62 529 232 0.23 / 185.63 2 2
2 7 2002.68 30 12.99 3193 1244 1.48 / 186.87 2 2
3 13 1842.88 20 13.28 2993 795 2.27 / 187.67 2 2
4 13 1430.68 20 13.55 2419 656 2.93 / 188.32 2 3
5 13 990.32 20 13.84 1825 505 3.43 / 188.83 2 3
6 13 317.60 20 14.38 879 253 3.68 / 189.08 2 3
7 14 -0.20 190 14.39 375 1025 4.71 / 190.11 2 11
Average= 4.75 (KJ/cycle)

Cycle 38 GMT 23/ 9/2015 16:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 30 14.59 548 240 0.24 / 180.86 2 2
2 7 2002.80 30 13.06 3223 1263 1.50 / 182.13 2 2
3 13 1831.60 20 13.30 3017 803 2.31 / 182.93 2 2
4 13 1614.08 20 13.44 2713 729 3.03 / 183.66 2 3
5 13 943.32 20 13.89 1756 488 3.52 / 184.15 2 3
6 13 276.24 20 14.43 808 233 3.76 / 184.38 2 3
7 14 0.08 190 14.40 372 1018 4.77 / 185.40 2 11
Average= 4.75 (KJ/cycle)

Cycle 37 GMT 13/ 9/2015 16:38: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 30 14.60 538 236 0.24 / 176.12 2 2
2 7 2001.96 30 13.11 3227 1269 1.50 / 177.39 2 2
3 13 1829.32 20 13.31 2999 798 2.30 / 178.19 2 3
4 13 1417.96 20 13.57 2430 660 2.96 / 178.85 2 3
5 13 979.88 20 13.87 1813 503 3.47 / 179.35 2 3
6 13 297.28 20 14.41 845 244 3.71 / 179.59 2 3
7 14 -0.16 190 14.36 378 1031 4.74 / 180.62 2 12
Average= 4.75 (KJ/cycle)

Cycle 36 GMT 3/ 9/2015 16:32: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 30 14.61 536 235 0.23 / 171.24 2 2
2 7 2002.80 30 13.15 3213 1268 1.50 / 172.50 2 2
3 13 1830.68 20 13.32 3018 804 2.31 / 173.31 2 3
4 13 1611.96 20 13.46 2716 731 3.04 / 174.04 2 3
5 13 937.24 20 13.90 1760 489 3.53 / 174.53 2 3
6 13 475.80 20 14.27 1101 314 3.84 / 174.84 2 3
7 14 -0.12 190 14.38 381 1041 4.88 / 175.88 2 13
Average= 4.75 (KJ/cycle)

Cycle 35 GMT 24/ 8/2015 16:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 30 14.60 543 238 0.24 / 166.43 2 2
2 7 2000.80 30 13.20 3217 1274 1.51 / 167.70 2 2
3 13 1825.48 20 13.33 3009 802 2.31 / 168.50 2 3
4 13 1608.60 20 13.48 2712 731 3.05 / 169.23 2 3
5 13 939.64 20 13.91 1772 493 3.54 / 169.73 2 3
6 13 264.60 20 14.45 803 232 3.77 / 169.96 2 3
7 14 0.08 190 14.37 382 1043 4.81 / 171.00 2 13
Average= 4.75 (KJ/cycle)

Cycle 34 GMT 14/ 8/2015 16:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 30 14.62 542 238 0.24 / 161.59 2 2
2 7 2001.40 30 13.24 3227 1282 1.52 / 162.88 2 2
3 13 1825.88 20 13.35 3009 803 2.32 / 163.68 2 2
4 13 1609.80 20 13.49 2716 733 3.06 / 164.41 2 3
5 13 936.28 20 13.92 1768 492 3.55 / 164.90 2 3
6 13 256.64 20 14.47 792 229 3.78 / 165.13 2 3
7 14 -0.04 190 14.38 386 1055 4.83 / 166.19 2 13
Average= 4.75 (KJ/cycle)

Cycle 33 GMT 4/ 8/2015 16:24: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 30 14.59 550 241 0.24 / 156.76 2 2
2 7 2004.36 30 13.28 3240 1291 1.53 / 158.05 2 2
3 13 1839.80 20 13.35 3037 811 2.34 / 158.86 2 2
4 13 1625.16 20 13.49 2728 736 3.08 / 159.60 2 3
5 13 940.36 20 13.93 1767 492 3.57 / 160.09 2 3
6 13 264.48 20 14.46 799 231 3.80 / 160.32 2 3
7 14 0.12 190 14.40 378 1034 4.84 / 161.36 2 12
Average= 4.75 (KJ/cycle)

Cycle 32 GMT 25/ 7/2015 16:12: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 30 14.60 545 239 0.24 / 151.82 2 2
2 7 2000.52 30 13.31 3211 1282 1.52 / 153.10 2 2
3 13 1822.20 20 13.38 3000 803 2.32 / 153.91 2 3
4 13 1607.04 20 13.51 2708 732 3.06 / 154.64 2 3
5 13 932.12 20 13.94 1755 489 3.54 / 155.13 2 3
6 13 258.48 20 14.46 793 229 3.77 / 155.36 2 3
7 13 27.16 20 14.66 440 129 3.90 / 155.49 2 3
8 14 0.12 190 14.34 380 1035 4.94 / 156.52 2 15
Average= 4.74 (KJ/cycle)

Cycle 31 GMT 15/ 7/2015 16:10: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 30 14.62 540 237 0.24 / 147.03 2 2
2 7 2002.08 30 13.33 3233 1293 1.53 / 148.33 2 2
3 13 1828.08 20 13.38 3009 805 2.33 / 149.13 2 3
4 13 1418.60 20 13.62 2453 668 3.00 / 149.80 2 3
5 13 969.96 20 13.91 1818 506 3.51 / 150.31 2 3
6 13 275.24 20 14.46 823 238 3.75 / 150.54 2 3
7 14 0.12 190 14.39 380 1039 4.79 / 151.58 2 11
Average= 4.74 (KJ/cycle)

Cycle 30 GMT 5/ 7/2015 16: 9: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 30 14.60 564 247 0.25 / 142.18 2 2
2 7 2002.16 30 13.34 3228 1292 1.54 / 143.48 2 2
3 13 1828.32 20 13.37 3042 813 2.35 / 144.29 2 2
4 13 1611.88 20 13.50 2737 739 3.09 / 145.03 2 3
5 13 932.20 20 13.94 1767 493 3.58 / 145.52 2 3
6 13 260.12 20 14.47 797 231 3.81 / 145.75 2 3
7 14 -0.12 191 14.39 380 1044 4.86 / 146.80 2 12
Average= 4.74 (KJ/cycle)

Cycle 29 GMT 25/ 6/2015 16: 7: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 30 14.61 538 236 0.24 / 137.38 2 2
2 7 2002.20 30 13.32 3246 1297 1.53 / 138.68 2 2
3 13 1833.16 20 13.38 3035 812 2.35 / 139.49 2 2
4 13 1415.92 20 13.63 2442 666 3.01 / 140.16 2 3
5 13 971.84 20 13.93 1805 503 3.51 / 140.66 2 3
6 13 284.32 20 14.45 830 240 3.75 / 140.90 2 3
7 14 0.00 190 14.39 380 1039 4.79 / 141.94 2 14
Average= 4.73 (KJ/cycle)

Cycle 28 GMT 15/ 6/2015 16: 3: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 30 14.62 541 237 0.24 / 132.52 2 2
2 7 2002.76 30 13.31 3239 1293 1.53 / 133.81 2 2
3 13 1838.16 20 13.36 3046 814 2.34 / 134.63 2 2
4 13 1622.84 20 13.50 2742 740 3.08 / 135.37 2 3
5 13 939.64 20 13.94 1769 493 3.58 / 135.86 2 3
6 13 258.44 20 14.48 799 231 3.81 / 136.09 2 3
7 14 0.08 191 14.38 384 1055 4.86 / 137.15 2 14
Average= 4.73 (KJ/cycle)

Cycle 27 GMT 5/ 6/2015 16: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 30 14.64 544 239 0.24 / 127.67 2 3
2 7 2001.52 30 13.33 3235 1294 1.53 / 128.97 2 2
3 13 1829.32 20 13.37 3027 809 2.34 / 129.78 2 2
4 13 1611.16 20 13.52 2716 734 3.08 / 130.51 2 3
5 13 935.72 20 13.95 1758 490 3.57 / 131.00 2 3
6 13 260.56 20 14.48 798 231 3.80 / 131.23 2 3
7 14 0.00 190 14.37 384 1048 4.85 / 132.28 2 16
Average= 4.72 (KJ/cycle)

Cycle 26 GMT 26/ 5/2015 15:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 30 14.63 542 238 0.24 / 122.84 2 3
2 7 2001.60 30 13.34 3219 1288 1.53 / 124.13 2 2
3 13 1831.60 20 13.37 3003 803 2.33 / 124.93 2 2
4 13 1616.12 20 13.51 2733 738 3.07 / 125.67 2 3
5 13 934.68 20 13.94 1774 495 3.56 / 126.16 2 4
6 13 264.68 20 14.48 805 233 3.80 / 126.40 2 3
7 14 -0.16 190 14.41 379 1038 4.83 / 127.43 2 10
Average= 4.72 (KJ/cycle)

Cycle 25 GMT 16/ 5/2015 15:58: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 30 14.65 531 233 0.23 / 118.03 2 2
2 7 2001.68 30 13.31 3235 1292 1.53 / 119.32 2 2
3 13 1836.08 20 13.35 3044 813 2.34 / 120.14 2 3
4 13 1422.00 20 13.64 2449 668 3.01 / 120.80 2 3
5 13 984.80 20 13.92 1840 512 3.52 / 121.32 2 3
6 13 291.04 20 14.45 847 245 3.76 / 121.56 2 3
7 14 -0.12 190 14.40 380 1040 4.80 / 122.60 2 10
Average= 4.72 (KJ/cycle)

Cycle 24 GMT 6/ 5/2015 16:31: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 30 14.66 536 236 0.24 / 113.24 2 2
2 7 2001.12 30 13.30 3219 1284 1.52 / 114.52 2 2
3 13 1825.96 20 13.38 3008 805 2.33 / 115.33 2 2
4 13 1610.76 20 13.52 2724 737 3.06 / 116.06 2 3
5 13 931.16 20 13.95 1752 489 3.55 / 116.55 2 3
6 13 254.60 20 14.49 781 226 3.78 / 116.78 2 3
7 14 -0.08 190 14.41 373 1021 4.80 / 117.80 2 14
Average= 4.71 (KJ/cycle)

Cycle 23 GMT 26/ 4/2015 17: 8: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 30 14.67 544 239 0.24 / 108.45 2 2
2 7 2003.36 30 13.31 3239 1293 1.53 / 109.74 2 2
3 13 1831.60 20 13.37 3030 810 2.34 / 110.55 2 2
4 13 1411.80 20 13.65 2425 662 3.00 / 111.22 2 3
5 13 968.28 20 13.94 1807 504 3.51 / 111.72 2 3
6 13 279.24 20 14.47 831 240 3.75 / 111.96 2 3
7 14 0.04 190 14.41 380 1040 4.79 / 113.00 2 12
Average= 4.71 (KJ/cycle)

Cycle 22 GMT 16/ 4/2015 17:39: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 30 14.66 550 242 0.24 / 103.57 2 2
2 7 2001.36 30 13.33 3231 1292 1.53 / 104.87 2 2
3 13 1828.56 21 13.39 3028 851 2.39 / 105.72 2 2
4 13 1411.84 21 13.66 2432 698 3.08 / 106.42 2 3
5 13 968.68 20 13.94 1808 504 3.59 / 106.92 2 3
6 13 276.68 20 14.48 828 240 3.83 / 107.16 2 3
7 14 -0.08 190 14.41 384 1051 4.88 / 108.21 2 13
Average= 4.70 (KJ/cycle)

Cycle 21 GMT 6/ 4/2015 18:15: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 30 14.71 528 233 0.23 / 98.78 2 3
2 7 2002.96 30 13.34 3228 1292 1.52 / 100.07 2 2
3 13 1829.96 20 13.40 3023 810 2.34 / 100.88 2 2
4 13 1413.92 20 13.66 2442 667 3.00 / 101.55 2 3
5 13 967.44 20 13.94 1812 505 3.51 / 102.05 2 3
6 13 270.20 20 14.49 821 238 3.75 / 102.29 2 3
7 14 0.00 190 14.42 381 1044 4.79 / 103.33 2 10
Average= 4.70 (KJ/cycle)

Cycle 20 GMT 27/ 3/2015 18:50: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 30 14.73 520 230 0.23 / 94.04 3 3
2 7 2004.72 30 13.35 3227 1292 1.52 / 95.33 2 2
3 13 1828.92 20 13.40 3017 809 2.33 / 96.14 2 2
4 13 1411.72 20 13.68 2423 663 2.99 / 96.80 2 3
5 13 960.28 20 13.96 1787 499 3.49 / 97.30 2 3
6 13 275.64 20 14.49 812 235 3.73 / 97.53 2 3
7 14 0.12 191 14.45 366 1010 4.74 / 98.54 2 16
Average= 4.69 (KJ/cycle)

Cycle 19 GMT 17/ 3/2015 19:14: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 30 14.71 530 234 0.23 / 89.24 2 2
2 7 2006.52 31 13.34 3242 1341 1.57 / 90.59 2 2
3 13 1820.76 20 13.42 3000 805 2.38 / 91.39 2 2
4 13 1399.52 20 13.69 2417 662 3.04 / 92.05 2 3
5 13 954.64 20 13.96 1789 499 3.54 / 92.55 2 3
6 13 251.48 20 14.51 785 228 3.77 / 92.78 2 3
7 14 -0.20 190 14.44 374 1026 4.79 / 93.81 2 16
Average= 4.69 (KJ/cycle)

Cycle 18 GMT 7/ 3/2015 19:45: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 30 14.70 533 235 0.24 / 84.43 2 2
2 7 2001.44 30 13.38 3227 1295 1.53 / 85.72 2 2
3 13 1828.44 20 13.42 3015 809 2.34 / 86.53 2 2
4 13 1609.24 20 13.55 2710 734 3.07 / 87.27 2 3
5 13 916.08 20 13.99 1732 485 3.56 / 87.75 2 3
6 13 232.20 20 14.54 751 218 3.78 / 87.97 2 3
7 14 0.00 190 14.44 379 1040 4.82 / 89.01 2 12
Average= 4.68 (KJ/cycle)

Cycle 17 GMT 25/ 2/2015 20:23: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 30 14.72 532 235 0.23 / 79.62 2 2
2 7 2001.72 30 13.41 3227 1298 1.53 / 80.92 2 2
3 13 1831.28 20 13.41 3046 817 2.35 / 81.73 2 3
4 13 1413.36 20 13.67 2447 669 3.02 / 82.40 2 3
5 13 968.52 20 13.95 1819 508 3.53 / 82.91 2 3
6 13 270.36 20 14.51 818 237 3.76 / 83.15 2 3
7 14 -0.08 190 14.44 381 1045 4.81 / 84.19 2 12
Average= 4.68 (KJ/cycle)

Cycle 16 GMT 15/ 2/2015 20:59: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 29 14.72 535 228 0.23 / 74.74 2 3
2 7 2005.52 30 13.41 3231 1300 1.53 / 76.04 2 2
3 13 1828.68 20 13.42 3038 815 2.34 / 76.86 2 3
4 13 1410.20 20 13.68 2433 666 3.01 / 77.52 2 3
5 13 958.96 20 13.96 1789 499 3.51 / 78.02 2 3
6 13 255.20 20 14.53 787 229 3.74 / 78.25 2 3
7 13 21.56 20 14.78 415 123 3.86 / 78.37 2 4
8 14 0.00 190 14.42 369 1011 4.87 / 79.38 2 13
Average= 4.67 (KJ/cycle)

Cycle 15 GMT 5/ 2/2015 21:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 29 14.73 534 228 0.23 / 69.93 2 2
2 7 2006.52 30 13.42 3235 1302 1.53 / 71.23 2 2
3 13 1829.36 21 13.43 3010 849 2.38 / 72.08 2 2
4 13 1413.88 21 13.67 2432 698 3.08 / 72.78 2 3
5 13 961.00 21 13.95 1789 524 3.60 / 73.30 2 3
6 13 145.04 21 14.65 627 193 3.79 / 73.50 2 3
7 14 -0.08 190 14.44 371 1018 4.81 / 74.51 2 12
Average= 4.66 (KJ/cycle)

Cycle 14 GMT 26/ 1/2015 21:54: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 29 14.72 541 231 0.23 / 65.13 2 2
2 7 2003.04 30 13.43 3241 1306 1.54 / 66.44 2 2
3 13 1828.12 20 13.42 3030 813 2.35 / 67.25 2 2
4 13 1404.84 20 13.67 2436 666 3.02 / 67.91 2 3
5 13 959.20 20 13.95 1802 503 3.52 / 68.42 2 3
6 13 256.44 20 14.54 800 233 3.75 / 68.65 2 3
7 14 0.16 190 14.44 383 1051 4.80 / 69.70 2 12
Average= 4.65 (KJ/cycle)

Cycle 13 GMT 16/ 1/2015 22:28: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 29 14.72 549 234 0.23 / 60.32 2 2
2 7 2005.80 30 13.42 3249 1308 1.54 / 61.63 2 2
3 13 1823.88 20 13.42 3007 807 2.35 / 62.43 2 2
4 13 1401.08 20 13.66 2432 664 3.01 / 63.10 2 3
5 13 957.36 20 13.94 1801 502 3.52 / 63.60 2 3
6 13 269.28 20 14.52 817 237 3.75 / 63.84 2 3
7 14 0.00 190 14.43 387 1061 4.81 / 64.90 2 13
Average= 4.64 (KJ/cycle)

Cycle 12 GMT 6/ 1/2015 22:58: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 29 14.72 554 236 0.24 / 55.55 2 2
2 7 2002.92 30 13.44 3236 1305 1.54 / 56.85 2 2
3 13 1824.32 20 13.41 3039 815 2.36 / 57.67 2 2
4 13 1411.60 20 13.64 2453 669 3.03 / 58.34 2 3
5 13 963.24 20 13.93 1816 506 3.53 / 58.84 2 3
6 13 143.32 20 14.66 634 186 3.72 / 59.03 2 3
7 14 -0.04 190 14.42 385 1055 4.77 / 60.08 2 11
Average= 4.62 (KJ/cycle)

Cycle 11 GMT 27/12/2014 23:25: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 29 14.72 561 239 0.24 / 50.59 2 2
2 7 2005.24 30 13.44 3249 1310 1.55 / 51.90 2 2
3 13 1832.84 20 13.41 3036 814 2.36 / 52.72 2 2
4 13 1404.96 20 13.63 2445 667 3.03 / 53.38 2 3
5 13 959.96 20 13.92 1816 506 3.54 / 53.89 2 3
6 13 262.60 20 14.54 808 235 3.77 / 54.12 2 3
7 13 6.00 20 14.81 415 123 3.89 / 54.25 2 3
8 14 -0.04 190 14.37 390 1065 4.96 / 55.31 2 12
Average= 4.61 (KJ/cycle)

Cycle 10 GMT 17/12/2014 23:47: 3

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 29 14.71 549 234 0.23 / 45.64 2 2
2 7 2002.68 30 13.46 3235 1306 1.54 / 46.94 2 2
3 13 1819.28 20 13.43 3014 810 2.35 / 47.75 2 2
4 13 1398.92 20 13.63 2440 665 3.02 / 48.42 2 3
5 13 947.36 20 13.93 1791 499 3.51 / 48.92 2 3
6 13 262.40 20 14.54 820 238 3.75 / 49.15 2 3
7 13 7.88 20 14.80 424 126 3.88 / 49.28 2 4
8 14 -0.08 190 14.35 394 1074 4.95 / 50.35 2 17
Average= 4.58 (KJ/cycle)

Cycle 9 GMT 8/12/2014 0:10: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 29 14.66 565 240 0.24 / 40.82 2 2
2 7 2003.72 30 13.47 3238 1308 1.55 / 42.13 2 2
3 13 1821.64 20 13.41 3030 813 2.36 / 42.94 2 2
4 13 1397.40 20 13.63 2422 660 3.02 / 43.60 2 3
5 13 949.04 20 13.94 1782 497 3.52 / 44.09 2 3
6 13 246.80 20 14.56 785 229 3.75 / 44.32 2 3
7 14 -0.16 190 14.40 394 1078 4.82 / 45.40 2 11
Average= 4.54 (KJ/cycle)

Cycle 8 GMT 28/11/2014 0:36: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 29 14.69 557 237 0.24 / 35.32 2 2
2 7 2003.80 74 12.95 3235 3100 3.34 / 38.42 2 2
3 13 1008.80 20 13.89 1871 520 3.86 / 38.94 2 3
4 13 317.60 20 14.48 891 258 4.12 / 39.19 2 3
5 14 0.04 241 14.34 400 1382 5.50 / 40.58 2 23
Average= 4.51 (KJ/cycle)

Cycle 7 GMT 18/11/2014 1:30: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 29 14.68 574 244 0.24 / 29.81 2 2
2 7 2002.36 74 12.92 3231 3089 3.33 / 32.90 2 2
3 13 998.88 21 13.88 1850 539 3.87 / 33.44 2 3
4 13 294.92 21 14.50 866 264 4.14 / 33.70 2 3
5 14 0.00 240 14.35 399 1374 5.51 / 35.08 2 26
Average= 4.38 (KJ/cycle)

Cycle 6 GMT 8/11/2014 2:21: 2

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 28 14.65 579 238 0.24 / 24.32 2 2
2 7 2000.64 74 12.91 3229 3085 3.32 / 27.41 2 2
3 13 1003.12 20 13.86 1862 516 3.84 / 27.92 2 3
4 13 319.12 20 14.47 904 262 4.10 / 28.18 2 3
5 14 0.16 240 14.32 403 1385 5.49 / 29.57 2 25
Average= 4.22 (KJ/cycle)

Cycle 5 GMT 29/10/2014 3:11: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 24 14.68 579 204 0.20 / 18.70 2 2
2 10 1003.36 3 14.65 1889 83 0.29 / 18.78 2 2
3 3 1035.48 1 14.65 1915 28 0.32 / 18.81 2 2
4 7 2005.36 74 12.87 3226 3072 3.39 / 21.88 2 2
5 13 1003.08 20 13.83 1874 518 3.91 / 22.40 2 3
6 13 325.96 20 14.45 919 266 4.17 / 22.67 2 3
7 14 -0.16 241 14.30 411 1416 5.59 / 24.08 2 22
Average= 4.01 (KJ/cycle)

Cycle 4 GMT 19/10/2014 3:57: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 28 14.62 565 231 0.23 / 13.99 2 2
2 7 1512.04 74 13.13 2577 2504 2.74 / 16.50 2 2
3 13 791.44 20 13.97 1577 441 3.18 / 16.94 2 3
4 13 78.12 20 14.69 537 158 3.33 / 17.09 2 3
5 14 0.08 241 14.25 408 1401 4.73 / 18.50 2 35
Average= 3.70 (KJ/cycle)

Cycle 3 GMT 18/10/2014 4:34: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 28 14.64 488 200 0.20 / 9.51 2 2
2 7 1510.04 75 13.09 2494 2448 2.65 / 11.96 2 3
3 13 596.24 20 14.14 1216 344 2.99 / 12.30 2 3
4 13 81.24 20 14.69 470 138 3.13 / 12.44 2 3
5 14 0.04 240 14.27 386 1322 4.45 / 13.76 2 35
Average= 3.44 (KJ/cycle)

Cycle 2 GMT 17/10/2014 5: 7: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 24 14.62 502 176 0.18 / 5.09 2 2
2 10 1032.60 3 14.43 1879 81 0.26 / 5.17 2 2
3 3 1035.76 1 14.43 1900 27 0.28 / 5.20 2 2
4 7 1501.28 75 12.96 2484 2414 2.70 / 7.61 2 2
5 13 780.08 20 13.90 1478 411 3.11 / 8.02 2 3
6 13 142.68 20 14.55 562 164 3.27 / 8.19 2 3
7 14 -0.16 240 14.33 326 1121 4.39 / 9.31 2 36
Average= 3.10 (KJ/cycle)

Cycle 1 GMT 16/10/2014 6: 4: 1

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 27 14.55 487 191 0.19 / 1.96 2 2
2 3 1050.92 1 14.11 1931 27 0.22 / 1.98 2 2
3 3 1030.36 1 14.13 1896 27 0.25 / 2.01 2 2
4 7 1014.68 74 13.20 1810 1768 2.01 / 3.78 2 3
5 14 -0.04 241 14.26 330 1134 3.15 / 4.91 2 29
Average= 2.46 (KJ/cycle)

Cycle 0 GMT 15/10/2014 18:41: 0

Number Code Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 26 14.54 490 185 0.19 / 0.19 2 2
2 7 121.76 74 14.23 491 517 0.70 / 0.70 2 3
3 14 -0.16 241 14.33 308 1064 1.77 / 1.77 2 59
Average= 1.77 (KJ/cycle)