Cycle 8 GMT 15/ 5/2024 11:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 31 15.26 426 202 0.20 / 27.07 2 3
2 3 910.52 -2 15.60 0 0 0.00 / 27.07 2 3
3 3 926.00 -1 15.63 0 0 0.00 / 27.07 2 3
4 7 2006.44 74 14.82 2847 3122 3.32 / 30.19 2 10
5 13 455.56 18 15.22 923 253 3.58 / 30.44 2 16
6 13 59.16 18 15.32 363 100 3.68 / 30.54 2 12
7 8 0.20 165 15.31 267 674 4.35 / 31.22 2 19
8 14 0.20 75 15.27 263 301 4.65 / 31.52 2 21
Average= 3.50
(KJ/cycle)

Cycle 7 GMT 5/ 5/2024 14:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 27 15.26 420 173 0.17 / 23.07 2 3
2 7 1805.88 74 14.88 2607 2871 3.04 / 25.94 2 10
3 13 205.96 18 15.28 567 156 3.20 / 26.09 2 14
4 13 54.60 18 15.33 350 97 3.30 / 26.19 2 11
5 8 0.12 165 15.30 267 674 3.97 / 26.86 2 19
Average= 3.36
(KJ/cycle)

Cycle 6 GMT 4/ 5/2024 13:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 27 15.26 418 172 0.17 / 19.02 2 3
2 3 1022.92 1 15.28 1736 27 0.20 / 19.05 2 10
3 7 1805.52 74 14.87 2603 2864 3.06 / 21.91 2 10
4 13 309.84 18 15.26 717 197 3.26 / 22.11 2 15
5 13 73.88 18 15.32 380 105 3.36 / 22.21 2 12
6 8 0.08 165 15.29 270 681 4.05 / 22.89 2 18
Average= 3.27
(KJ/cycle)

Cycle 5 GMT 3/ 5/2024 12:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 27 15.27 402 166 0.17 / 15.03 2 3
2 7 1805.48 74 14.88 2607 2871 3.04 / 17.90 2 10
3 13 252.60 18 15.29 636 175 3.21 / 18.08 2 15
4 13 46.88 18 15.33 340 94 3.31 / 18.17 2 13
5 8 0.12 165 15.30 269 679 3.98 / 18.85 2 22
Average= 3.14
(KJ/cycle)

Cycle 4 GMT 2/ 5/2024 11:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.76 26 15.29 422 168 0.17 / 11.38 2 3
2 10 1009.52 2 15.26 1694 52 0.22 / 11.43 2 7
3 7 1528.08 74 15.00 2274 2524 2.74 / 13.96 2 12
4 13 144.44 18 15.33 480 132 2.88 / 14.09 2 13
5 13 48.04 18 15.34 338 93 2.97 / 14.18 2 11
6 8 -0.08 165 15.32 269 680 3.65 / 14.86 2 17
Average= 2.97
(KJ/cycle)

Cycle 3 GMT 1/ 5/2024 12: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 20 15.28 405 124 0.12 / 7.60 2 3
2 10 1020.20 4 15.25 1685 103 0.23 / 7.71 2 6
3 10 1052.20 2 15.24 1747 53 0.28 / 7.76 2 6
4 3 1039.28 1 15.28 1758 27 0.31 / 7.79 2 11
5 7 1524.72 74 14.97 2267 2511 2.82 / 10.30 2 11
6 13 144.92 18 15.33 483 133 2.95 / 10.43 2 13
7 13 52.44 18 15.33 349 96 3.05 / 10.53 2 12
8 8 -0.16 165 15.31 272 687 3.73 / 11.21 2 19
Average= 2.80
(KJ/cycle)

Cycle 2 GMT 30/ 4/2024 12:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.40 33 15.33 437 221 0.22 / 4.10 2 4
2 3 780.64 -4 15.62 1 0 0.00 / 4.10 2 4
3 3 809.76 -4 15.65 1 0 0.00 / 4.10 2 4
4 7 1507.84 74 15.00 2243 2490 2.71 / 6.59 2 11
5 13 127.04 18 15.33 457 126 2.84 / 6.71 2 13
6 13 35.00 18 15.34 321 89 2.93 / 6.80 2 13
7 8 0.00 165 15.31 269 680 3.61 / 7.48 2 22
Average= 2.49
(KJ/cycle)

Cycle 1 GMT 29/ 4/2024 12:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 28 15.52 373 162 0.16 / 1.45 3 3
2 3 923.28 -1 15.66 0 0 0.00 / 1.45 3 3
3 3 941.20 -1 15.68 1 0 0.00 / 1.45 3 3
4 7 950.76 74 15.19 1541 1732 1.89 / 3.18 2 14
5 8 0.04 165 15.38 272 690 2.58 / 3.87 2 21
Average= 1.94
(KJ/cycle)

Cycle 0 GMT 29/ 4/2024 1:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.44 28 15.67 300 132 0.13 / 0.13 3 3
2 7 71.48 74 15.63 319 369 0.50 / 0.50 3 3
3 8 0.08 240 15.59 211 789 1.29 / 1.29 3 10
Average= 1.29