SIO Argo Site:
Pump Diagnostics Page   



Serial= 3206 WMO= 4903766

Return

←PreviousNext→

Cycle 8 GMT 14/ 5/2024 16:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 31 15.21 451 213 0.21 / 27.76 3 3
2 3 919.88 -2 15.63 2 0 0.00 / 27.76 3 3
3 3 968.28 -1 15.65 3 0 0.00 / 27.76 3 3
4 7 2004.08 75 14.80 2876 3192 3.41 / 30.95 2 5
5 13 317.16 18 15.27 765 210 3.62 / 31.16 2 6
6 13 101.80 18 15.30 454 125 3.74 / 31.28 2 6
7 8 0.12 165 15.27 298 751 4.49 / 32.03 3 3
Average= 3.56
(KJ/cycle)

Cycle 7 GMT 4/ 5/2024 19: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 28 15.24 408 174 0.17 / 23.54 3 3
2 7 1815.08 74 14.85 2638 2899 3.07 / 26.44 2 6
3 13 410.00 18 15.24 870 239 3.31 / 26.68 2 7
4 13 100.60 18 15.29 427 118 3.43 / 26.80 2 6
5 8 0.20 165 15.26 297 748 4.18 / 27.54 2 7
Average= 3.44
(KJ/cycle)

Cycle 6 GMT 3/ 5/2024 18:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 27 15.23 403 166 0.17 / 19.42 3 3
2 3 1026.44 1 15.29 1752 27 0.19 / 19.45 2 6
3 7 1817.36 74 14.87 2637 2902 3.09 / 22.35 2 7
4 13 374.52 18 15.26 822 226 3.32 / 22.57 2 8
5 13 83.96 18 15.30 404 111 3.43 / 22.69 2 4
6 8 0.04 165 15.27 270 680 4.11 / 23.37 2 3
Average= 3.34
(KJ/cycle)

Cycle 5 GMT 2/ 5/2024 17:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 27 15.26 408 168 0.17 / 15.36 3 3
2 7 1817.16 74 14.88 2640 2907 3.08 / 18.26 2 7
3 13 318.04 18 15.27 744 204 3.28 / 18.47 2 7
4 13 88.88 18 15.31 410 113 3.39 / 18.58 2 7
5 8 0.04 165 15.28 267 673 4.07 / 19.25 2 10
Average= 3.21
(KJ/cycle)

Cycle 4 GMT 1/ 5/2024 16:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 27 15.25 403 166 0.17 / 11.72 3 3
2 7 1523.72 75 14.97 2282 2562 2.73 / 14.29 2 7
3 13 138.88 18 15.31 482 133 2.86 / 14.42 2 5
4 13 54.92 18 15.31 361 99 2.96 / 14.52 2 4
5 8 0.08 165 15.28 266 671 3.63 / 15.19 2 7
Average= 3.04
(KJ/cycle)

Cycle 3 GMT 30/ 4/2024 16:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 25 15.25 412 157 0.16 / 8.08 3 3
2 10 1013.48 2 15.27 1702 52 0.21 / 8.13 2 4
3 7 1516.52 74 14.98 2274 2521 2.73 / 10.65 2 10
4 13 134.80 18 15.32 477 132 2.86 / 10.78 2 5
5 13 71.08 18 15.31 380 105 2.97 / 10.88 2 7
6 8 -0.04 165 15.28 267 673 3.64 / 11.56 2 11
Average= 2.89
(KJ/cycle)

Cycle 2 GMT 29/ 4/2024 17: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 33 15.27 429 216 0.22 / 4.49 3 3
2 3 790.52 -4 15.65 1 0 0.00 / 4.49 3 3
3 3 905.72 -2 15.66 1 0 0.00 / 4.49 3 3
4 7 1525.08 74 14.98 2281 2529 2.74 / 7.02 2 9
5 13 126.72 18 15.31 462 127 2.87 / 7.14 2 5
6 13 67.96 18 15.31 375 103 2.98 / 7.25 2 4
7 8 0.08 165 15.28 266 671 3.65 / 7.92 3 3
Average= 2.64
(KJ/cycle)

Cycle 1 GMT 28/ 4/2024 17: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 28 15.44 369 160 0.16 / 1.76 3 3
2 3 939.52 -1 15.64 1 0 0.00 / 1.76 3 3
3 3 966.20 -1 15.67 2 0 0.00 / 1.76 3 3
4 7 993.84 75 15.15 1610 1829 1.99 / 3.59 2 8
5 8 0.04 165 15.33 271 685 2.67 / 4.27 2 15
Average= 2.14
(KJ/cycle)

Cycle 0 GMT 28/ 4/2024 6:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 159.20 28 15.58 464 202 0.20 / 0.20 3 3
2 7 173.36 74 15.54 466 536 0.74 / 0.74 3 3
3 8 0.04 240 15.51 231 860 1.60 / 1.60 3 8
Average= 1.60
(KJ/cycle)