SIO Argo Site:
Pump Diagnostics Page   



Serial= 7884 WMO= 4903557

Return

←PreviousNext→

Cycle 69 GMT 15/ 5/2024 22:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 20 14.60 775 226 0.23 / 397.50 5 6
2 3 1522.24 1 14.49 2874 42 0.27 / 397.55 5 17
3 7 2005.12 40 14.24 3268 1861 2.13 / 399.41 17 19
4 13 1475.32 20 14.29 2593 741 2.87 / 400.15 5 23
5 13 877.84 20 14.40 1836 529 3.40 / 400.68 5 26
6 13 232.76 20 14.64 982 288 3.69 / 400.96 5 24
7 13 73.32 20 14.68 780 229 3.92 / 401.19 5 23
8 8 0.00 287 14.59 639 2676 6.59 / 403.87 5 171
Average= 5.77
(KJ/cycle)

Cycle 68 GMT 10/ 5/2024 21:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 19 14.60 803 223 0.22 / 390.75 5 6
2 3 1546.48 1 14.50 2772 40 0.26 / 390.79 5 18
3 7 2007.68 40 14.26 3252 1855 2.12 / 392.65 18 17
4 13 1468.00 20 14.28 2617 747 2.87 / 393.39 5 23
5 13 912.76 20 14.39 1921 553 3.42 / 393.95 5 29
6 13 262.60 20 14.62 1044 305 3.72 / 394.25 5 25
7 13 66.24 20 14.70 779 229 3.95 / 394.48 5 25
8 8 0.04 287 14.59 668 2797 6.75 / 397.28 5 150
Average= 5.76
(KJ/cycle)

Cycle 67 GMT 5/ 5/2024 21: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 18 14.60 790 208 0.21 / 383.98 5 6
2 3 1522.00 1 14.52 2797 41 0.25 / 384.02 5 16
3 7 2013.00 40 14.25 3296 1879 2.13 / 385.90 16 18
4 13 1418.04 20 14.30 2539 726 2.85 / 386.63 5 25
5 13 974.24 20 14.38 1972 567 3.42 / 387.20 5 28
6 13 254.84 20 14.62 1058 309 3.73 / 387.51 5 26
7 13 89.64 20 14.68 792 233 3.96 / 387.74 5 24
8 8 0.08 289 14.58 662 2789 6.75 / 390.53 5 156
Average= 5.74
(KJ/cycle)

Cycle 66 GMT 30/ 4/2024 20:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 18 14.58 828 217 0.22 / 377.17 5 6
2 7 2004.88 40 14.25 3287 1874 2.09 / 379.05 6 16
3 13 1472.36 20 14.30 2639 755 2.85 / 379.80 5 20
4 13 880.72 20 14.42 1849 533 3.38 / 380.34 5 27
5 13 241.56 20 14.63 1030 301 3.68 / 380.64 5 25
6 13 44.48 20 14.70 765 225 3.91 / 380.86 5 21
7 8 0.00 291 14.58 687 2915 6.82 / 383.78 5 134
Average= 5.73
(KJ/cycle)

Cycle 65 GMT 25/ 4/2024 19:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 20 14.60 775 226 0.23 / 370.49 5 8
2 3 1427.16 -1 15.20 0 0 0.00 / 370.49 5 8
3 7 2004.68 40 14.28 3256 1860 2.09 / 372.35 8 16
4 13 1413.72 20 14.32 2532 725 2.81 / 373.08 5 25
5 13 833.80 20 14.44 1768 511 3.32 / 373.59 5 27
6 13 221.04 20 14.62 1006 294 3.62 / 373.88 5 28
7 8 0.08 314 14.58 671 3072 6.69 / 376.96 5 147
Average= 5.71
(KJ/cycle)

Cycle 64 GMT 20/ 4/2024 18:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 19 14.62 844 234 0.23 / 363.71 5 6
2 3 1560.04 2 14.51 2737 79 0.31 / 363.79 5 17
3 7 2005.72 40 14.27 3259 1860 2.17 / 365.65 17 17
4 13 1513.44 20 14.31 2619 750 2.92 / 366.40 5 19
5 13 943.64 20 14.41 1936 558 3.48 / 366.95 5 26
6 13 213.20 20 14.65 984 288 3.77 / 367.24 5 26
7 13 22.40 20 14.71 714 210 3.98 / 367.45 5 26
8 8 -0.04 291 14.59 663 2815 6.79 / 370.27 5 129
Average= 5.70
(KJ/cycle)

Cycle 63 GMT 15/ 4/2024 18:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 18 14.65 801 211 0.21 / 357.02 5 7
2 7 2010.68 40 14.26 3316 1891 2.10 / 358.91 14 18
3 13 1512.16 20 14.30 2690 769 2.87 / 359.68 5 24
4 13 857.16 20 14.42 1875 541 3.41 / 360.22 5 28
5 13 232.36 20 14.66 1001 293 3.71 / 360.51 5 24
6 13 50.16 20 14.72 754 222 3.93 / 360.73 5 12
7 8 0.16 285 14.61 658 2740 6.67 / 363.47 5 145
Average= 5.68
(KJ/cycle)

Cycle 62 GMT 10/ 4/2024 17:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.20 19 14.62 810 225 0.23 / 350.40 5 7
2 7 2004.84 40 14.27 3266 1864 2.09 / 352.26 7 19
3 13 1496.52 20 14.31 2637 755 2.84 / 353.01 5 24
4 13 903.84 20 14.43 1853 535 3.38 / 353.55 5 29
5 13 288.08 20 14.64 1070 313 3.69 / 353.86 5 23
6 13 29.56 20 14.74 710 209 3.90 / 354.07 5 19
7 8 0.00 282 14.62 663 2733 6.63 / 356.81 5 196
Average= 5.66
(KJ/cycle)

Cycle 61 GMT 5/ 4/2024 17: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 20 14.63 808 236 0.24 / 343.61 5 6
2 3 1444.88 -1 15.21 0 0 0.00 / 343.61 5 6
3 7 2015.48 40 14.26 3322 1895 2.13 / 345.50 6 18
4 13 1442.36 20 14.33 2575 738 2.87 / 346.24 5 23
5 13 852.08 20 14.44 1820 526 3.39 / 346.77 5 30
6 13 246.12 20 14.66 1023 300 3.69 / 347.07 5 24
7 13 28.76 20 14.73 757 223 3.92 / 347.29 5 21
8 8 0.08 282 14.61 699 2880 6.80 / 350.17 5 138
Average= 5.65
(KJ/cycle)

Cycle 60 GMT 31/ 3/2024 16:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 19 14.60 779 216 0.22 / 336.61 5 6
2 10 1502.88 3 14.52 2567 112 0.33 / 336.72 5 14
3 7 2005.84 41 14.28 3279 1920 2.25 / 338.64 14 18
4 13 1460.20 20 14.33 2632 754 3.00 / 339.39 5 23
5 13 863.84 20 14.44 1888 545 3.55 / 339.94 5 28
6 13 225.12 20 14.67 997 293 3.84 / 340.23 5 26
7 13 34.56 20 14.73 754 222 4.06 / 340.45 5 21
8 8 0.20 287 14.61 696 2918 6.98 / 343.37 5 141
Average= 5.63
(KJ/cycle)

Cycle 59 GMT 26/ 3/2024 15:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 19 14.59 810 225 0.22 / 329.71 5 6
2 7 2007.60 40 14.29 3299 1886 2.11 / 331.59 6 16
3 13 1519.84 20 14.32 2688 770 2.88 / 332.36 5 22
4 13 843.08 20 14.46 1806 522 3.40 / 332.88 5 30
5 13 173.80 20 14.67 946 278 3.68 / 333.16 5 28
6 13 23.64 20 14.72 729 215 3.89 / 333.38 5 23
7 8 -0.20 300 14.59 689 3016 6.91 / 336.39 5 142
Average= 5.61
(KJ/cycle)

Cycle 58 GMT 21/ 3/2024 14:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 19 14.63 782 217 0.22 / 322.85 5 6
2 7 2003.80 40 14.29 3266 1867 2.08 / 324.71 6 18
3 13 1467.72 20 14.33 2585 741 2.83 / 325.45 5 24
4 13 863.12 20 14.45 1854 536 3.36 / 325.99 5 27
5 13 147.96 20 14.69 888 261 3.62 / 326.25 5 28
6 8 0.04 321 14.59 690 3232 6.85 / 329.48 5 139
Average= 5.58
(KJ/cycle)

Cycle 57 GMT 16/ 3/2024 14:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 20 14.65 766 224 0.22 / 316.16 5 6
2 3 1459.16 -1 15.21 0 0 0.00 / 316.16 5 6
3 7 2004.76 40 14.28 3273 1870 2.09 / 318.03 6 20
4 13 1454.52 20 14.35 2565 736 2.83 / 318.76 5 23
5 13 929.00 20 14.43 1929 557 3.39 / 319.32 5 29
6 13 199.84 20 14.69 942 277 3.66 / 319.60 5 24
7 13 45.20 20 14.74 732 216 3.88 / 319.81 5 12
8 8 -0.04 291 14.62 662 2816 6.70 / 322.63 5 148
Average= 5.56
(KJ/cycle)

Cycle 56 GMT 11/ 3/2024 13:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 20 14.63 781 229 0.23 / 309.60 5 6
2 7 2012.04 40 14.28 3275 1871 2.10 / 311.47 6 19
3 13 1446.40 20 14.36 2539 729 2.83 / 312.20 5 25
4 13 849.64 20 14.47 1778 515 3.34 / 312.71 5 29
5 13 204.20 20 14.70 930 273 3.62 / 312.99 5 27
6 13 86.32 20 14.73 755 222 3.84 / 313.21 5 26
7 8 0.08 287 14.63 649 2725 6.56 / 315.93 5 136
Average= 5.54
(KJ/cycle)

Cycle 55 GMT 6/ 3/2024 13:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 18 14.64 785 207 0.21 / 302.70 5 7
2 10 1502.20 3 14.52 2550 111 0.32 / 302.81 5 14
3 3 1460.00 -1 15.21 0 0 0.11 / 302.81 5 14
4 7 2013.00 41 14.28 3285 1923 2.24 / 304.74 14 18
5 13 1475.60 20 14.34 2638 757 3.00 / 305.49 5 23
6 13 880.08 20 14.46 1859 538 3.54 / 306.03 5 29
7 13 269.48 20 14.67 1027 301 3.84 / 306.33 5 27
8 13 65.40 20 14.74 764 225 4.06 / 306.56 5 19
9 8 -0.08 289 14.63 665 2812 6.87 / 309.37 5 141
Average= 5.52
(KJ/cycle)

Cycle 54 GMT 1/ 3/2024 12:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 19 14.59 840 233 0.23 / 296.04 5 7
2 7 2007.92 41 14.30 3260 1911 2.14 / 297.95 7 18
3 13 1426.56 20 14.37 2532 728 2.87 / 298.67 5 26
4 13 847.60 20 14.49 1775 514 3.39 / 299.19 5 31
5 13 235.48 20 14.68 990 291 3.68 / 299.48 5 30
6 13 34.60 20 14.75 713 210 3.89 / 299.69 5 29
7 8 -0.04 291 14.63 659 2806 6.69 / 302.50 5 145
Average= 5.50
(KJ/cycle)

Cycle 53 GMT 25/ 2/2024 12: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 20 14.61 810 237 0.24 / 289.12 5 6
2 3 1446.80 -1 15.21 0 0 0.00 / 289.12 5 6
3 7 2009.28 40 14.30 3269 1870 2.11 / 290.99 6 17
4 13 1356.52 20 14.39 2438 702 2.81 / 291.69 5 23
5 13 945.00 20 14.45 1923 556 3.36 / 292.25 5 28
6 13 183.60 20 14.69 935 275 3.64 / 292.52 5 26
7 8 0.00 328 14.61 685 3283 6.92 / 295.80 5 165
Average= 5.48
(KJ/cycle)

Cycle 52 GMT 20/ 2/2024 11:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 18 14.67 777 205 0.21 / 282.22 5 6
2 3 1561.44 2 14.54 2707 79 0.28 / 282.30 5 21
3 7 2004.76 40 14.29 3259 1863 2.15 / 284.17 21 21
4 13 1465.28 20 14.35 2592 744 2.89 / 284.91 5 27
5 13 864.68 20 14.47 1850 535 3.43 / 285.44 5 30
6 13 190.20 20 14.69 966 284 3.71 / 285.73 5 30
7 8 0.12 319 14.62 676 3153 6.86 / 288.88 5 131
Average= 5.45
(KJ/cycle)

Cycle 51 GMT 15/ 2/2024 11: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 18 14.67 777 205 0.21 / 275.69 5 7
2 7 2004.48 40 14.29 3249 1857 2.06 / 277.55 7 19
3 13 1463.60 20 14.37 2574 740 2.80 / 278.29 5 23
4 13 907.80 20 14.48 1867 541 3.34 / 278.83 5 29
5 13 225.76 20 14.71 969 285 3.63 / 279.12 5 25
6 13 80.44 20 14.76 790 233 3.86 / 279.35 5 15
7 8 0.20 280 14.66 650 2668 6.53 / 282.02 5 168
Average= 5.42
(KJ/cycle)

Cycle 50 GMT 10/ 2/2024 10:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 19 14.68 782 218 0.22 / 269.14 5 6
2 7 2005.80 40 14.30 3266 1868 2.09 / 271.01 6 17
3 13 1456.80 20 14.36 2621 753 2.84 / 271.76 5 25
4 13 862.64 20 14.49 1825 529 3.37 / 272.29 5 29
5 13 252.08 20 14.71 1006 296 3.66 / 272.58 5 25
6 13 132.36 20 14.74 837 247 3.91 / 272.83 5 20
7 8 0.16 282 14.67 643 2660 6.57 / 275.49 5 165
Average= 5.40
(KJ/cycle)

Cycle 49 GMT 5/ 2/2024 9:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 19 14.66 810 226 0.23 / 262.41 5 6
2 7 2013.72 40 14.30 3295 1885 2.11 / 264.30 6 21
3 13 1479.52 20 14.36 2646 760 2.87 / 265.06 5 26
4 13 880.52 20 14.48 1872 542 3.41 / 265.60 5 29
5 13 301.04 20 14.68 1118 328 3.74 / 265.93 5 21
6 13 100.28 20 14.75 838 247 3.99 / 266.18 5 21
7 8 -0.20 280 14.66 668 2742 6.73 / 268.92 5 151
Average= 5.38
(KJ/cycle)

Cycle 48 GMT 31/ 1/2024 9:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 18 14.69 793 210 0.21 / 255.68 5 6
2 7 2010.36 40 14.30 3276 1874 2.08 / 257.56 16 18
3 13 1434.24 20 14.37 2582 742 2.83 / 258.30 5 26
4 13 840.20 20 14.50 1820 528 3.35 / 258.83 5 31
5 13 270.28 20 14.70 1059 311 3.66 / 259.14 5 25
6 13 111.20 20 14.75 858 253 3.92 / 259.39 5 18
7 8 0.12 282 14.66 677 2799 6.72 / 262.19 5 160
Average= 5.35
(KJ/cycle)

Cycle 47 GMT 26/ 1/2024 8:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 20 14.67 828 243 0.24 / 248.98 5 6
2 3 1439.88 -1 15.23 0 0 0.00 / 248.98 5 6
3 7 2013.08 40 14.29 3318 1897 2.14 / 250.87 6 19
4 13 1481.60 20 14.35 2663 764 2.90 / 251.64 5 26
5 13 912.48 20 14.48 1911 553 3.46 / 252.19 5 29
6 13 236.40 20 14.72 1031 304 3.76 / 252.49 5 23
7 13 125.48 20 14.76 844 249 4.01 / 252.74 5 19
8 8 -0.08 280 14.68 664 2729 6.74 / 255.47 5 148
Average= 5.32
(KJ/cycle)

Cycle 46 GMT 21/ 1/2024 7:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 18 14.68 816 216 0.22 / 242.16 5 6
2 10 1501.20 2 14.52 2701 78 0.29 / 242.24 5 14
3 7 2016.00 40 14.31 3303 1891 2.18 / 244.13 14 17
4 13 1471.96 20 14.37 2645 760 2.94 / 244.89 5 25
5 13 814.48 20 14.52 1785 518 3.46 / 245.40 5 28
6 13 255.32 20 14.71 1062 312 3.78 / 245.72 5 23
7 13 100.16 20 14.76 838 247 4.02 / 245.96 5 22
8 8 0.12 278 14.67 679 2769 6.79 / 248.73 5 143
Average= 5.29
(KJ/cycle)

Cycle 45 GMT 16/ 1/2024 7: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 19 14.68 812 226 0.23 / 235.33 5 6
2 3 1463.44 -1 15.23 0 0 0.00 / 235.33 5 6
3 7 2003.32 40 14.30 3289 1881 2.11 / 237.21 6 19
4 13 1505.28 20 14.36 2668 766 2.87 / 237.97 5 25
5 13 912.48 20 14.48 1904 551 3.43 / 238.53 5 30
6 13 259.92 20 14.71 1058 311 3.74 / 238.84 5 24
7 13 104.68 20 14.76 848 250 3.99 / 239.09 5 19
8 8 -0.08 282 14.67 690 2854 6.84 / 241.94 5 156
Average= 5.26
(KJ/cycle)

Cycle 44 GMT 11/ 1/2024 6:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 20 14.68 795 233 0.23 / 228.56 5 6
2 7 2016.92 40 14.31 3267 1870 2.10 / 230.43 6 17
3 13 1376.48 20 14.41 2467 711 2.81 / 231.14 5 25
4 13 900.56 20 14.49 1915 555 3.37 / 231.70 5 27
5 13 221.24 20 14.72 1006 296 3.67 / 231.99 5 25
6 13 108.00 20 14.76 854 252 3.92 / 232.24 5 21
7 8 0.04 285 14.67 683 2856 6.77 / 235.10 5 131
Average= 5.22
(KJ/cycle)

Cycle 43 GMT 6/ 1/2024 5:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 18 14.66 833 220 0.22 / 221.81 5 6
2 3 1545.80 1 14.50 2930 42 0.26 / 221.85 5 18
3 7 2011.76 40 14.30 3323 1901 2.16 / 223.75 18 17
4 13 1410.72 20 14.39 2541 731 2.89 / 224.49 5 25
5 13 836.16 20 14.51 1826 530 3.42 / 225.02 5 31
6 13 242.00 20 14.71 1024 301 3.73 / 225.32 5 25
7 13 78.76 20 14.76 797 235 3.96 / 225.55 5 24
8 8 -0.04 287 14.67 659 2775 6.74 / 228.33 5 137
Average= 5.19
(KJ/cycle)

Cycle 42 GMT 1/ 1/2024 4:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 19 14.62 1017 283 0.28 / 214.79 5 7
2 7 2010.84 41 14.29 3371 1975 2.26 / 216.77 7 20
3 13 1468.36 20 14.37 2651 762 3.02 / 217.53 5 25
4 13 863.28 20 14.49 1903 551 3.57 / 218.08 5 32
5 13 223.72 20 14.71 1054 310 3.88 / 218.39 5 26
6 13 57.44 20 14.77 817 241 4.12 / 218.63 5 23
7 8 0.08 289 14.66 698 2957 7.08 / 221.59 5 152
Average= 5.15
(KJ/cycle)

Cycle 41 GMT 27/12/2023 4:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.04 18 14.67 826 218 0.22 / 207.73 5 6
2 3 1520.00 1 14.53 2932 43 0.26 / 207.78 5 17
3 7 2004.80 40 14.31 3353 1919 2.18 / 209.69 17 19
4 13 1491.92 20 14.36 2733 785 2.96 / 210.48 5 24
5 13 852.80 20 14.51 1834 532 3.50 / 211.01 5 30
6 13 254.16 20 14.71 1098 323 3.82 / 211.33 5 27
7 13 59.28 20 14.78 832 246 4.07 / 211.58 5 21
8 8 -0.04 285 14.67 701 2931 7.00 / 214.51 5 164
Average= 5.11
(KJ/cycle)

Cycle 40 GMT 22/12/2023 3:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 18 14.66 819 216 0.22 / 200.69 5 6
2 7 2014.12 40 14.31 3337 1910 2.13 / 202.60 6 18
3 13 1511.92 20 14.38 2692 774 2.90 / 203.37 5 26
4 13 939.12 20 14.48 2005 581 3.48 / 203.95 5 29
5 13 222.40 20 14.73 1059 312 3.79 / 204.26 5 27
6 13 100.84 20 14.76 865 255 4.05 / 204.52 5 25
7 8 0.36 289 14.66 707 2995 7.04 / 207.51 5 189
Average= 5.06
(KJ/cycle)

Cycle 39 GMT 17/12/2023 3: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 18 14.66 857 226 0.23 / 193.69 5 6
2 7 2010.56 40 14.30 3360 1922 2.15 / 195.61 6 18
3 13 1466.56 20 14.39 2659 765 2.91 / 196.38 5 26
4 13 867.20 20 14.51 1877 545 3.46 / 196.92 5 30
5 13 220.56 20 14.72 1046 308 3.77 / 197.23 5 28
6 13 27.52 20 14.78 780 231 4.00 / 197.46 5 27
7 8 -0.08 291 14.66 706 3012 7.01 / 200.47 5 140
Average= 5.01
(KJ/cycle)

Cycle 38 GMT 12/12/2023 2:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 19 14.67 858 239 0.24 / 186.72 5 7
2 3 1466.36 -1 15.25 0 0 0.00 / 186.72 5 7
3 7 2014.08 40 14.31 3358 1922 2.16 / 188.64 7 20
4 13 1503.92 20 14.39 2655 764 2.93 / 189.41 5 25
5 13 814.84 20 14.52 1809 525 3.45 / 189.93 5 31
6 13 177.48 20 14.74 981 289 3.74 / 190.22 5 28
7 8 0.12 310 14.67 713 3243 6.98 / 193.46 5 139
Average= 4.96
(KJ/cycle)

Cycle 37 GMT 7/12/2023 1:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.72 18 14.69 787 208 0.21 / 179.80 5 6
2 3 1531.04 1 14.61 2768 40 0.25 / 179.84 5 15
3 7 2014.00 40 14.34 3268 1875 2.12 / 181.71 15 18
4 13 1512.16 20 14.39 2662 766 2.89 / 182.48 5 23
5 13 839.08 20 14.53 1814 527 3.42 / 183.01 5 30
6 13 196.12 20 14.74 962 284 3.70 / 183.29 5 27
7 13 78.32 20 14.78 799 236 3.94 / 183.52 5 24
8 8 0.00 289 14.67 697 2955 6.89 / 186.48 5 148
Average= 4.91
(KJ/cycle)

Cycle 36 GMT 2/12/2023 1: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 18 14.73 769 204 0.20 / 172.98 5 6
2 7 2010.88 40 14.33 3268 1873 2.08 / 174.85 6 19
3 13 1396.28 20 14.43 2509 724 2.80 / 175.57 5 25
4 13 881.16 20 14.51 1875 544 3.35 / 176.12 5 30
5 13 228.36 20 14.74 1026 302 3.65 / 176.42 5 27
6 13 105.84 20 14.77 855 253 3.90 / 176.67 5 24
7 8 0.00 287 14.68 692 2916 6.82 / 179.59 5 144
Average= 4.85
(KJ/cycle)

Cycle 35 GMT 27/11/2023 0:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.92 18 14.75 775 206 0.21 / 166.70 5 6
2 7 2004.64 40 14.35 3186 1829 2.03 / 168.53 6 21
3 13 1424.08 20 14.43 2487 718 2.75 / 169.25 5 24
4 13 837.40 20 14.56 1744 508 3.26 / 169.76 5 30
5 13 233.16 20 14.77 937 277 3.54 / 170.03 5 24
6 13 86.76 20 14.82 741 220 3.76 / 170.25 5 20
7 8 0.08 278 14.74 615 2520 6.28 / 172.77 5 157
Average= 4.80
(KJ/cycle)

Cycle 34 GMT 21/11/2023 23:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 18 14.77 677 180 0.18 / 160.59 5 7
2 7 2003.60 40 14.35 3194 1833 2.01 / 162.42 13 20
3 13 1459.08 20 14.43 2520 727 2.74 / 163.15 5 25
4 13 826.48 20 14.57 1725 503 3.24 / 163.65 5 29
5 13 251.76 20 14.76 959 283 3.53 / 163.94 5 24
6 13 99.56 20 14.82 737 218 3.74 / 164.15 5 20
7 8 0.12 278 14.75 571 2341 6.09 / 166.50 5 149
Average= 4.76
(KJ/cycle)

Cycle 33 GMT 16/11/2023 23:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.04 18 14.78 663 176 0.18 / 154.68 5 6
2 7 2009.80 40 14.37 3137 1803 1.98 / 156.48 6 17
3 13 1504.60 20 14.45 2471 714 2.69 / 157.19 5 24
4 13 893.76 20 14.57 1747 509 3.20 / 157.70 5 29
5 13 249.56 20 14.79 884 261 3.46 / 157.96 5 22
6 13 71.04 20 14.85 634 188 3.65 / 158.15 5 18
7 8 0.12 276 14.77 554 2258 5.91 / 160.41 5 131
Average= 4.72
(KJ/cycle)

Cycle 32 GMT 11/11/2023 22:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 18 14.81 608 162 0.16 / 148.94 5 6
2 7 2007.72 40 14.39 3102 1786 1.95 / 150.72 6 20
3 13 1471.88 20 14.47 2430 703 2.65 / 151.43 5 25
4 13 876.12 20 14.58 1696 495 3.15 / 151.92 5 29
5 13 235.20 20 14.80 830 246 3.39 / 152.17 5 25
6 13 120.84 20 14.84 672 199 3.59 / 152.37 5 21
7 8 0.08 278 14.79 519 2134 5.72 / 154.50 5 163
Average= 4.68
(KJ/cycle)

Cycle 31 GMT 6/11/2023 21:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 18 14.81 587 156 0.16 / 143.45 5 6
2 7 2007.76 40 14.40 3056 1760 1.92 / 145.21 6 22
3 13 1416.12 20 14.49 2334 676 2.59 / 145.89 5 25
4 13 858.84 20 14.59 1651 482 3.07 / 146.37 5 29
5 13 236.76 20 14.81 804 238 3.31 / 146.61 5 25
6 13 90.60 20 14.86 581 173 3.49 / 146.78 5 20
7 8 0.04 276 14.80 488 1993 5.48 / 148.77 5 148
Average= 4.65
(KJ/cycle)

Cycle 30 GMT 1/11/2023 21:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 18 14.81 600 160 0.16 / 137.98 5 6
2 7 2012.48 41 14.40 3055 1804 1.96 / 139.79 6 22
3 13 1431.76 20 14.49 2341 678 2.64 / 140.47 5 24
4 13 875.36 20 14.59 1655 483 3.12 / 140.95 5 30
5 13 251.48 20 14.81 809 240 3.36 / 141.19 5 26
6 13 96.24 20 14.86 590 175 3.54 / 141.36 5 22
7 8 0.08 278 14.81 469 1931 5.47 / 143.30 5 152
Average= 4.62
(KJ/cycle)

Cycle 29 GMT 27/10/2023 20:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 18 14.82 582 155 0.16 / 132.66 5 7
2 7 2016.20 40 14.40 3037 1749 1.90 / 134.41 7 21
3 13 1478.48 20 14.49 2348 680 2.59 / 135.09 5 28
4 13 822.00 20 14.62 1545 452 3.04 / 135.54 5 30
5 13 173.96 20 14.83 663 197 3.23 / 135.74 5 28
6 13 61.52 20 14.87 506 150 3.38 / 135.89 5 25
7 8 0.04 285 14.80 459 1936 5.32 / 137.82 5 159
Average= 4.59
(KJ/cycle)

Cycle 28 GMT 22/10/2023 20: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 18 14.82 558 149 0.15 / 127.42 5 6
2 7 2007.56 41 14.43 2997 1773 1.92 / 129.20 6 19
3 13 1468.00 20 14.49 2350 681 2.60 / 129.88 5 26
4 13 826.72 20 14.63 1536 449 3.05 / 130.33 5 31
5 13 203.56 20 14.83 692 205 3.26 / 130.53 5 28
6 13 82.60 20 14.87 526 156 3.41 / 130.69 5 27
7 8 -0.04 285 14.82 430 1816 5.23 / 132.50 5 142
Average= 4.57
(KJ/cycle)

Cycle 27 GMT 17/10/2023 19:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 18 14.81 551 147 0.15 / 122.22 5 6
2 3 1519.24 1 14.67 2397 35 0.18 / 122.26 5 20
3 7 2014.56 40 14.43 2993 1728 1.91 / 123.98 20 20
4 13 1433.56 20 14.51 2288 664 2.57 / 124.65 5 26
5 13 839.08 20 14.62 1554 454 3.03 / 125.10 5 32
6 13 125.76 20 14.87 550 164 3.19 / 125.27 5 29
7 13 53.68 20 14.88 476 142 3.33 / 125.41 5 28
8 8 0.12 291 14.81 433 1866 5.20 / 127.27 5 150
Average= 4.55
(KJ/cycle)

Cycle 26 GMT 12/10/2023 18:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 18 14.82 533 142 0.14 / 117.08 5 6
2 7 2003.72 41 14.44 2974 1761 1.90 / 118.85 6 17
3 13 1421.48 20 14.52 2260 656 2.56 / 119.50 5 26
4 13 825.84 20 14.64 1506 441 3.00 / 119.94 5 32
5 13 93.72 20 14.87 516 153 3.15 / 120.10 5 30
6 13 29.08 20 14.89 427 127 3.28 / 120.22 5 30
7 8 -0.20 297 14.81 421 1852 5.13 / 122.08 5 157
Average= 4.52
(KJ/cycle)

Cycle 25 GMT 7/10/2023 18: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 18 14.83 501 134 0.13 / 112.08 5 6
2 7 2008.68 40 14.45 2976 1720 1.85 / 113.80 6 17
3 13 1436.84 20 14.53 2237 650 2.50 / 114.45 5 24
4 13 838.92 20 14.63 1544 452 2.96 / 114.90 5 31
5 13 154.28 20 14.85 575 171 3.13 / 115.07 5 31
6 13 23.36 20 14.90 411 122 3.25 / 115.20 5 29
7 8 -0.08 293 14.83 402 1747 5.00 / 116.94 5 132
Average= 4.50
(KJ/cycle)

Cycle 24 GMT 2/10/2023 17:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 17 14.85 515 130 0.13 / 107.04 5 6
2 7 2004.28 40 14.46 2956 1710 1.84 / 108.75 6 20
3 13 1456.56 20 14.52 2295 666 2.51 / 109.41 5 24
4 13 855.48 20 14.63 1543 451 2.96 / 109.87 5 30
5 13 132.80 20 14.86 569 169 3.13 / 110.03 5 32
6 13 25.40 20 14.90 419 125 3.25 / 110.16 5 30
7 8 -0.16 297 14.82 406 1787 5.04 / 111.95 5 149
Average= 4.48
(KJ/cycle)

Cycle 23 GMT 27/ 9/2023 16:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 17 14.84 504 127 0.13 / 102.08 5 6
2 7 2007.40 40 14.46 2965 1715 1.84 / 103.80 6 20
3 13 1459.28 20 14.52 2313 672 2.51 / 104.47 5 25
4 13 790.80 20 14.64 1474 432 2.95 / 104.90 5 31
5 13 74.88 20 14.89 483 144 3.09 / 105.04 5 29
6 13 28.92 20 14.90 424 126 3.22 / 105.17 5 30
7 8 -0.08 295 14.83 397 1737 4.95 / 106.91 5 136
Average= 4.45
(KJ/cycle)

Cycle 22 GMT 22/ 9/2023 15:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 17 14.85 500 126 0.13 / 97.01 5 6
2 7 2011.44 40 14.46 2980 1724 1.85 / 98.74 6 19
3 13 1513.48 20 14.52 2342 680 2.53 / 99.42 5 23
4 13 858.84 20 14.64 1529 448 2.98 / 99.87 5 31
5 13 129.88 20 14.86 555 165 3.14 / 100.03 5 31
6 13 24.64 20 14.90 409 122 3.26 / 100.15 5 30
7 8 -0.12 304 14.83 400 1803 5.07 / 101.96 5 156
Average= 4.43
(KJ/cycle)

Cycle 21 GMT 17/ 9/2023 15: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 17 14.85 497 125 0.13 / 92.13 5 6
2 7 2003.56 40 14.46 2949 1706 1.83 / 93.84 6 18
3 13 1460.12 20 14.53 2285 664 2.50 / 94.50 5 26
4 13 779.72 20 14.67 1420 417 2.91 / 94.92 5 31
5 13 70.68 20 14.90 460 137 3.05 / 95.06 5 32
6 13 27.40 20 14.91 396 118 3.17 / 95.17 5 29
7 8 -0.08 300 14.84 385 1714 4.88 / 96.89 5 156
Average= 4.40
(KJ/cycle)

Cycle 20 GMT 12/ 9/2023 14:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 17 14.86 494 125 0.12 / 87.33 5 6
2 7 2007.76 40 14.46 2950 1706 1.83 / 89.04 6 18
3 13 1386.08 20 14.56 2169 632 2.46 / 89.67 5 25
4 13 784.44 20 14.68 1402 412 2.87 / 90.08 5 31
5 13 68.12 20 14.91 448 134 3.01 / 90.22 5 30
6 13 23.92 20 14.92 398 119 3.13 / 90.34 5 29
7 8 -0.08 297 14.85 379 1672 4.80 / 92.01 5 147
Average= 4.38
(KJ/cycle)

Cycle 19 GMT 7/ 9/2023 13:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 18 14.86 487 130 0.13 / 82.45 5 6
2 7 2005.56 40 14.48 2939 1702 1.83 / 84.16 6 19
3 13 1470.28 20 14.54 2288 665 2.50 / 84.82 5 24
4 13 831.88 20 14.66 1491 437 2.94 / 85.26 5 30
5 13 114.12 20 14.89 505 150 3.09 / 85.41 5 29
6 13 19.72 20 14.92 389 116 3.20 / 85.52 5 28
7 8 -0.16 300 14.85 378 1684 4.89 / 87.21 5 135
Average= 4.36
(KJ/cycle)

Cycle 18 GMT 2/ 9/2023 13: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 18 14.86 476 127 0.13 / 77.62 5 6
2 7 2012.36 40 14.49 2946 1708 1.83 / 79.33 6 22
3 13 1429.16 20 14.55 2243 653 2.49 / 79.98 5 23
4 13 848.08 20 14.66 1505 441 2.93 / 80.42 5 30
5 13 163.20 20 14.88 568 169 3.10 / 80.59 5 30
6 13 23.44 20 14.92 385 115 3.21 / 80.70 5 27
7 8 0.00 297 14.86 367 1620 4.83 / 82.32 5 138
Average= 4.33
(KJ/cycle)

Cycle 17 GMT 28/ 8/2023 12:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 18 14.88 462 124 0.12 / 72.78 5 6
2 7 2013.84 40 14.48 2928 1696 1.82 / 74.48 6 19
3 13 1459.72 20 14.56 2244 653 2.47 / 75.13 5 23
4 13 818.04 20 14.67 1453 426 2.90 / 75.56 5 30
5 13 133.56 20 14.89 528 157 3.06 / 75.71 5 29
6 13 24.56 20 14.92 377 112 3.17 / 75.83 5 28
7 8 -0.20 302 14.86 371 1665 4.83 / 77.49 5 143
Average= 4.31
(KJ/cycle)

Cycle 16 GMT 23/ 8/2023 11:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 18 14.88 454 122 0.12 / 68.09 5 6
2 7 2013.88 41 14.49 2928 1739 1.86 / 69.82 6 21
3 13 1460.20 20 14.56 2248 655 2.52 / 70.48 5 25
4 13 806.56 20 14.68 1423 418 2.93 / 70.90 5 30
5 13 112.96 20 14.91 474 141 3.07 / 71.04 5 29
6 13 21.36 20 14.93 366 109 3.18 / 71.15 5 28
7 8 -0.16 295 14.87 344 1509 4.69 / 72.66 5 130
Average= 4.27
(KJ/cycle)

Cycle 15 GMT 18/ 8/2023 10:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 17 14.90 434 110 0.11 / 63.40 5 6
2 3 1525.56 1 14.77 2322 34 0.14 / 63.44 5 15
3 7 2005.60 41 14.49 2905 1726 1.87 / 65.16 15 18
4 13 1378.44 20 14.57 2145 625 2.50 / 65.79 5 23
5 13 780.12 20 14.69 1392 409 2.90 / 66.20 5 30
6 13 98.64 20 14.91 460 137 3.04 / 66.33 5 28
7 13 17.16 20 14.94 353 105 3.15 / 66.44 5 26
8 8 -0.12 297 14.88 345 1525 4.67 / 67.96 5 165
Average= 4.25
(KJ/cycle)

Cycle 14 GMT 13/ 8/2023 10: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 17 14.89 434 110 0.11 / 58.87 5 6
2 7 2012.12 40 14.50 2906 1685 1.80 / 60.56 6 18
3 13 1434.08 20 14.56 2220 646 2.44 / 61.20 5 23
4 13 825.76 20 14.68 1445 424 2.87 / 61.63 5 28
5 13 107.20 20 14.92 454 135 3.00 / 61.76 5 29
6 13 22.80 20 14.95 349 104 3.11 / 61.87 5 26
7 8 -0.04 289 14.89 331 1424 4.53 / 63.29 5 148
Average= 4.22
(KJ/cycle)

Cycle 13 GMT 8/ 8/2023 9:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 18 14.91 425 114 0.11 / 54.32 5 6
2 7 2015.48 40 14.50 2910 1688 1.80 / 56.00 6 18
3 13 1425.72 20 14.59 2172 634 2.44 / 56.64 5 25
4 13 861.12 20 14.68 1465 430 2.87 / 57.07 5 30
5 13 131.08 20 14.91 496 148 3.01 / 57.22 5 29
6 13 22.40 20 14.94 343 102 3.12 / 57.32 5 27
7 8 -0.08 300 14.89 323 1443 4.56 / 58.76 5 143
Average= 4.20
(KJ/cycle)

Cycle 12 GMT 3/ 8/2023 8:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 18 14.91 438 118 0.12 / 49.85 5 6
2 7 2003.64 40 14.51 2894 1680 1.80 / 51.53 6 18
3 13 1452.72 20 14.56 2209 643 2.44 / 52.17 5 22
4 13 806.28 20 14.70 1398 411 2.85 / 52.58 5 29
5 13 155.80 20 14.91 519 155 3.01 / 52.74 5 27
6 13 31.76 20 14.95 349 104 3.11 / 52.84 5 27
7 8 -0.08 293 14.90 312 1362 4.47 / 54.20 5 149
Average= 4.17
(KJ/cycle)

Cycle 11 GMT 29/ 7/2023 7:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 17 14.93 413 105 0.10 / 45.36 5 6
2 3 1525.32 1 14.78 2296 34 0.14 / 45.39 5 16
3 7 2012.52 40 14.51 2894 1680 1.82 / 47.07 16 18
4 13 1446.52 20 14.58 2185 637 2.46 / 47.71 5 22
5 13 806.32 20 14.69 1406 413 2.87 / 48.12 5 29
6 13 231.56 20 14.88 625 186 3.05 / 48.31 5 27
7 13 63.80 20 14.94 398 119 3.17 / 48.43 5 25
8 8 -0.04 285 14.91 307 1305 4.48 / 49.73 5 155
Average= 4.14
(KJ/cycle)

Cycle 10 GMT 24/ 7/2023 7:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 17 14.91 414 105 0.10 / 40.92 5 6
2 7 2012.32 41 14.51 2896 1723 1.83 / 42.65 6 19
3 13 1417.72 20 14.59 2165 632 2.46 / 43.28 5 22
4 13 859.96 20 14.69 1465 430 2.89 / 43.71 5 29
5 13 199.48 20 14.91 560 167 3.06 / 43.88 5 24
6 13 86.84 20 14.94 410 123 3.18 / 44.00 5 22
7 8 0.04 278 14.92 302 1253 4.43 / 45.25 5 148
Average= 4.11
(KJ/cycle)

Cycle 9 GMT 19/ 7/2023 6:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 17 14.92 406 103 0.10 / 36.38 5 6
2 10 1501.64 2 14.70 2277 67 0.17 / 36.44 5 13
3 3 1436.44 -1 15.32 0 0 0.07 / 36.44 5 13
4 7 2008.20 41 14.52 2878 1713 1.88 / 38.16 13 18
5 13 1348.36 20 14.60 2065 603 2.49 / 38.76 5 25
6 13 866.00 20 14.68 1480 435 2.92 / 39.19 5 30
7 13 205.84 20 14.89 590 176 3.10 / 39.37 5 29
8 13 90.28 20 14.93 425 127 3.22 / 39.50 5 27
9 8 0.12 287 14.91 309 1322 4.55 / 40.82 5 147
Average= 4.08
(KJ/cycle)

Cycle 8 GMT 14/ 7/2023 5:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 17 14.92 414 105 0.11 / 31.96 5 6
2 7 2005.04 40 14.53 2881 1674 1.78 / 33.63 6 18
3 13 1458.92 20 14.59 2207 644 2.42 / 34.28 5 22
4 13 929.60 20 14.67 1542 452 2.88 / 34.73 5 29
5 13 185.24 20 14.91 544 162 3.04 / 34.89 5 27
6 13 84.12 20 14.94 401 120 3.16 / 35.01 5 24
7 8 0.04 285 14.92 297 1263 4.42 / 36.27 5 157
Average= 4.03
(KJ/cycle)

Cycle 7 GMT 9/ 7/2023 5: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 18 14.94 399 107 0.11 / 27.60 5 6
2 7 2008.52 40 14.54 2864 1666 1.77 / 29.26 6 19
3 13 1379.84 20 14.60 2111 616 2.39 / 29.88 5 25
4 13 826.68 20 14.70 1407 414 2.80 / 30.29 5 29
5 13 214.44 20 14.89 587 175 2.98 / 30.47 5 30
6 13 46.88 20 14.95 357 107 3.08 / 30.57 5 29
7 13 12.16 20 14.95 312 93 3.18 / 30.67 5 26
8 8 0.00 270 14.91 295 1188 4.37 / 31.85 5 170
Average= 3.98
(KJ/cycle)

Cycle 6 GMT 4/ 7/2023 4:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 18 14.94 396 106 0.11 / 23.31 5 6
2 7 2003.60 40 14.53 2858 1661 1.77 / 24.97 6 19
3 13 1384.64 20 14.61 2114 618 2.39 / 25.59 5 25
4 13 865.80 20 14.69 1466 431 2.82 / 26.02 5 30
5 13 237.84 20 14.90 613 183 3.00 / 26.20 5 27
6 13 89.40 20 14.95 401 120 3.12 / 26.32 5 22
7 8 0.04 278 14.94 281 1167 4.29 / 27.49 5 139
Average= 3.93
(KJ/cycle)

Cycle 5 GMT 29/ 6/2023 3:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 17 14.92 419 106 0.11 / 18.96 5 6
2 7 2003.04 40 14.54 2880 1675 1.78 / 20.63 15 18
3 13 1442.52 20 14.60 2166 632 2.41 / 21.27 5 25
4 13 942.56 20 14.68 1559 458 2.87 / 21.72 5 29
5 13 292.68 20 14.89 673 200 3.07 / 21.92 5 26
6 13 128.68 20 14.94 457 137 3.21 / 22.06 5 22
7 8 0.08 278 14.94 275 1142 4.35 / 23.20 5 136
Average= 3.87
(KJ/cycle)

Cycle 4 GMT 24/ 6/2023 3:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 17 14.92 390 99 0.10 / 14.64 5 6
2 7 2014.40 40 14.55 2873 1672 1.77 / 16.32 6 19
3 13 1407.04 20 14.61 2129 622 2.39 / 16.94 5 26
4 13 816.16 20 14.71 1390 409 2.80 / 17.35 5 30
5 13 193.92 20 14.90 550 164 2.97 / 17.51 5 28
6 13 73.24 20 14.94 388 116 3.08 / 17.63 5 26
7 8 0.08 289 14.92 284 1225 4.31 / 18.85 5 144
Average= 3.77
(KJ/cycle)

Cycle 3 GMT 19/ 6/2023 2:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 17 14.92 388 98 0.10 / 10.45 5 6
2 7 2004.24 40 14.54 2862 1665 1.76 / 12.12 6 19
3 13 1310.04 20 14.63 1986 581 2.34 / 12.70 5 25
4 13 777.52 20 14.71 1352 398 2.74 / 13.10 5 30
5 13 217.60 20 14.90 582 173 2.92 / 13.27 5 27
6 13 103.52 20 14.94 417 125 3.04 / 13.40 5 24
7 8 0.04 282 14.93 273 1149 4.19 / 14.55 5 150
Average= 3.64
(KJ/cycle)

Cycle 2 GMT 14/ 6/2023 1:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.16 16 14.89 412 98 0.10 / 6.12 5 6
2 3 1536.72 1 14.74 2307 34 0.13 / 6.16 5 16
3 7 2009.92 40 14.55 2884 1678 1.81 / 7.84 16 18
4 13 1450.36 20 14.61 2181 637 2.45 / 8.47 5 25
5 13 857.60 20 14.70 1451 427 2.87 / 8.90 5 29
6 13 213.32 20 14.90 575 171 3.05 / 9.07 5 27
7 13 96.56 20 14.93 413 123 3.17 / 9.20 5 26
8 8 0.08 285 14.92 273 1161 4.33 / 10.36 5 158
Average= 3.45
(KJ/cycle)

Cycle 1 GMT 9/ 6/2023 1: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 18 15.04 391 106 0.11 / 1.84 5 6
2 3 1408.84 -1 15.33 0 0 0.00 / 1.84 5 6
3 7 2009.60 40 14.55 2851 1659 1.77 / 3.50 6 18
4 13 1434.12 20 14.59 2144 626 2.39 / 4.12 5 25
5 13 882.12 20 14.67 1473 432 2.82 / 4.55 5 29
6 13 299.04 20 14.85 691 205 3.03 / 4.76 5 25
7 13 136.40 20 14.90 460 137 3.17 / 4.90 5 21
8 8 0.16 282 14.90 269 1130 4.30 / 6.03 5 146
Average= 3.01
(KJ/cycle)

Cycle 0 GMT 4/ 6/2023 0:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 135.72 18 15.23 424 116 0.12 / 0.12 5 7
2 7 148.44 40 15.20 450 274 0.39 / 0.39 7 8
3 13 142.56 20 15.18 442 134 0.52 / 0.52 5 8
4 13 84.92 20 15.17 367 111 0.64 / 0.64 5 9
5 8 0.04 293 15.13 247 1095 1.73 / 1.73 5 144
Average= 1.73
(KJ/cycle)