SIO Argo Site:
Pump Diagnostics Page   



Serial= 7877 WMO= 4903551

Return

←PreviousNext→

Cycle 68 GMT 11/ 5/2024 11:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 17 14.78 433 109 0.11 / 280.01 6 6
2 7 2004.28 40 14.41 2648 1526 1.64 / 281.54 6 14
3 13 1546.16 20 14.43 2176 628 2.26 / 282.17 5 21
4 13 989.04 20 14.50 1568 455 2.72 / 282.62 5 28
5 13 353.12 20 14.70 767 225 2.94 / 282.85 5 22
6 13 149.96 20 14.77 493 146 3.09 / 282.99 5 22
7 8 0.08 265 14.78 280 1097 4.19 / 284.09 5 162
Average= 4.12
(KJ/cycle)

Cycle 67 GMT 6/ 5/2024 10:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.96 17 14.78 437 110 0.11 / 275.76 6 6
2 7 2004.60 41 14.38 2705 1595 1.70 / 277.35 6 19
3 13 1504.20 20 14.42 2134 615 2.32 / 277.97 5 25
4 13 1009.88 20 14.50 1594 462 2.78 / 278.43 5 29
5 13 348.96 20 14.71 767 226 3.01 / 278.65 5 23
6 13 144.36 20 14.77 487 144 3.15 / 278.80 5 22
7 8 0.08 265 14.78 283 1108 4.26 / 279.91 5 192
Average= 4.12
(KJ/cycle)

Cycle 66 GMT 1/ 5/2024 9:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 17 14.78 434 109 0.11 / 271.56 6 7
2 7 2007.88 41 14.38 2695 1589 1.70 / 273.15 7 14
3 13 1429.48 20 14.43 2080 600 2.30 / 273.75 5 20
4 13 922.64 20 14.53 1487 432 2.73 / 274.19 5 30
5 13 291.16 20 14.73 691 204 2.93 / 274.39 5 26
6 13 134.44 20 14.78 475 140 3.07 / 274.53 5 22
7 8 0.04 263 14.78 287 1116 4.19 / 275.65 5 154
Average= 4.11
(KJ/cycle)

Cycle 65 GMT 26/ 4/2024 9: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 17 14.79 415 104 0.10 / 267.34 6 7
2 7 2012.44 41 14.39 2693 1589 1.69 / 268.93 7 14
3 13 1459.80 20 14.45 2095 605 2.30 / 269.54 5 27
4 13 910.60 20 14.53 1475 429 2.73 / 269.97 5 26
5 13 350.80 20 14.71 772 227 2.95 / 270.19 5 27
6 13 146.40 20 14.78 494 146 3.10 / 270.34 5 20
7 8 0.16 265 14.78 285 1116 4.22 / 271.46 5 197
Average= 4.11
(KJ/cycle)

Cycle 64 GMT 21/ 4/2024 8:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 17 14.78 422 106 0.11 / 263.20 6 6
2 7 2012.84 40 14.38 2736 1574 1.68 / 264.77 6 16
3 13 1436.52 20 14.45 2081 601 2.28 / 265.37 5 21
4 13 921.28 20 14.54 1471 428 2.71 / 265.80 5 29
5 13 287.36 20 14.74 682 201 2.91 / 266.00 5 25
6 13 133.52 20 14.79 471 139 3.05 / 266.14 5 22
7 8 0.12 263 14.79 282 1097 4.15 / 267.24 5 161
Average= 4.11
(KJ/cycle)

Cycle 63 GMT 16/ 4/2024 7:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 17 14.79 439 110 0.11 / 259.03 6 6
2 7 2004.40 40 14.40 2651 1527 1.64 / 260.56 6 18
3 13 1445.72 20 14.45 2079 601 2.24 / 261.16 5 25
4 13 973.44 20 14.52 1552 451 2.69 / 261.61 5 27
5 13 328.68 20 14.72 742 218 2.91 / 261.83 5 30
6 13 119.80 20 14.79 459 136 3.04 / 261.96 5 26
7 8 0.12 265 14.78 289 1132 4.18 / 263.09 5 188
Average= 4.11
(KJ/cycle)

Cycle 62 GMT 11/ 4/2024 6:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 17 14.78 433 109 0.11 / 254.87 6 6
2 7 2009.84 40 14.43 2634 1520 1.63 / 256.40 6 15
3 13 1501.96 20 14.46 2097 606 2.24 / 257.00 5 18
4 13 951.44 20 14.54 1518 441 2.68 / 257.44 5 30
5 13 314.16 20 14.72 730 215 2.89 / 257.66 5 27
6 13 103.16 20 14.79 443 131 3.02 / 257.79 5 24
7 8 0.08 265 14.79 288 1129 4.15 / 258.92 5 139
Average= 4.11
(KJ/cycle)

Cycle 61 GMT 6/ 4/2024 5:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 17 14.78 434 109 0.11 / 250.66 5 6
2 7 2007.64 40 14.41 2643 1523 1.63 / 252.18 6 16
3 13 1505.36 20 14.45 2149 621 2.25 / 252.80 5 21
4 13 924.24 20 14.55 1482 431 2.68 / 253.23 5 29
5 13 477.36 20 14.66 938 275 2.96 / 253.51 5 29
6 13 75.52 20 14.81 401 119 3.08 / 253.63 5 27
7 8 0.04 265 14.79 291 1141 4.22 / 254.77 5 226
Average= 4.11
(KJ/cycle)

Cycle 60 GMT 1/ 4/2024 5:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 17 14.79 423 106 0.11 / 246.53 6 6
2 7 2007.72 40 14.39 2721 1566 1.67 / 248.10 6 15
3 13 1448.44 20 14.46 2081 602 2.27 / 248.70 5 23
4 13 892.52 20 14.55 1452 423 2.70 / 249.12 5 27
5 13 231.16 20 14.76 618 182 2.88 / 249.31 5 27
6 13 30.16 20 14.82 338 100 2.98 / 249.41 5 24
7 8 0.16 263 14.79 293 1140 4.12 / 250.55 5 173
Average= 4.11
(KJ/cycle)

Cycle 59 GMT 27/ 3/2024 4:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 17 14.77 437 110 0.11 / 242.43 5 6
2 7 2010.16 40 14.42 2648 1527 1.64 / 243.96 6 16
3 13 1450.64 20 14.47 2078 601 2.24 / 244.56 5 24
4 13 904.16 20 14.55 1462 425 2.66 / 244.99 5 30
5 13 233.08 20 14.75 629 186 2.85 / 245.17 5 31
6 13 27.56 20 14.83 340 101 2.95 / 245.27 5 26
7 8 -0.08 263 14.78 297 1154 4.10 / 246.43 5 214
Average= 4.11
(KJ/cycle)

Cycle 58 GMT 22/ 3/2024 3:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 17 14.78 434 109 0.11 / 238.25 6 6
2 7 2011.36 40 14.42 2675 1543 1.65 / 239.79 6 19
3 13 1491.76 20 14.46 2125 615 2.27 / 240.40 5 19
4 13 922.36 20 14.55 1493 434 2.70 / 240.84 5 26
5 13 316.92 20 14.72 742 218 2.92 / 241.06 5 32
6 8 0.20 282 14.78 304 1267 4.19 / 242.32 5 188
Average= 4.11
(KJ/cycle)

Cycle 57 GMT 17/ 3/2024 2:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 17 14.79 443 111 0.11 / 234.03 6 6
2 7 2005.96 40 14.44 2603 1503 1.61 / 235.53 6 19
3 13 1499.44 20 14.45 2168 627 2.24 / 236.16 5 17
4 13 1005.52 20 14.53 1595 464 2.70 / 236.62 5 27
5 13 356.08 20 14.71 797 234 2.94 / 236.86 5 32
6 13 27.88 20 14.83 345 102 3.04 / 236.96 5 27
7 8 -0.08 265 14.79 300 1176 4.22 / 238.14 5 200
Average= 4.11
(KJ/cycle)

Cycle 56 GMT 12/ 3/2024 2: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 17 14.78 427 107 0.11 / 229.87 5 6
2 7 2002.88 40 14.42 2672 1541 1.65 / 231.41 6 18
3 13 1504.48 20 14.46 2149 621 2.27 / 232.03 5 19
4 13 922.24 20 14.55 1486 432 2.70 / 232.46 5 26
5 13 283.28 20 14.74 695 205 2.91 / 232.67 5 28
6 13 51.84 20 14.83 372 110 3.02 / 232.78 5 24
7 8 0.16 263 14.80 293 1140 4.16 / 233.92 5 155
Average= 4.10
(KJ/cycle)

Cycle 55 GMT 7/ 3/2024 1:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 17 14.80 439 110 0.11 / 225.73 6 6
2 7 2006.48 40 14.43 2646 1527 1.64 / 227.26 6 16
3 13 1502.80 20 14.45 2145 620 2.26 / 227.88 5 21
4 13 903.92 20 14.56 1474 429 2.69 / 228.31 5 27
5 13 233.24 20 14.76 627 185 2.87 / 228.49 5 30
6 13 12.44 20 14.84 320 95 2.97 / 228.59 5 27
7 8 -0.12 263 14.78 302 1174 4.14 / 229.76 5 157
Average= 4.10
(KJ/cycle)

Cycle 54 GMT 2/ 3/2024 0:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.16 16 14.80 438 104 0.10 / 221.54 6 6
2 7 2009.32 40 14.40 2740 1578 1.68 / 223.12 6 16
3 13 1470.88 20 14.47 2089 605 2.29 / 223.73 5 24
4 13 950.92 20 14.55 1528 445 2.73 / 224.17 5 28
5 13 266.00 20 14.76 664 196 2.93 / 224.37 5 30
6 13 71.88 20 14.83 393 117 3.04 / 224.48 5 22
7 8 0.08 265 14.80 290 1137 4.18 / 225.62 5 223
Average= 4.10
(KJ/cycle)

Cycle 53 GMT 25/ 2/2024 23:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 17 14.81 417 105 0.10 / 217.37 6 6
2 7 2012.68 40 14.40 2733 1574 1.68 / 218.94 6 14
3 13 1516.52 20 14.47 2146 621 2.30 / 219.56 5 20
4 13 887.00 20 14.57 1451 423 2.72 / 219.98 5 28
5 13 267.80 20 14.76 665 196 2.92 / 220.18 5 27
6 13 102.88 20 14.82 432 128 3.05 / 220.31 5 23
7 8 0.04 265 14.81 288 1130 4.18 / 221.44 5 -99
Average= 4.10
(KJ/cycle)

Cycle 52 GMT 20/ 2/2024 23: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 17 14.81 417 105 0.10 / 213.21 6 6
2 7 2004.36 40 14.44 2627 1517 1.62 / 214.73 6 19
3 13 1455.00 20 14.49 2073 601 2.22 / 215.33 5 24
4 13 924.84 20 14.56 1496 436 2.66 / 215.77 5 27
5 13 333.64 20 14.74 752 222 2.88 / 215.99 5 29
6 13 127.36 20 14.81 467 138 3.02 / 216.13 5 22
7 8 0.12 265 14.81 289 1134 4.15 / 217.26 5 225
Average= 4.10
(KJ/cycle)

Cycle 51 GMT 15/ 2/2024 22:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 17 14.81 435 110 0.11 / 209.05 6 6
2 7 2012.72 41 14.42 2679 1584 1.69 / 210.63 6 16
3 13 1481.12 20 14.47 2109 610 2.30 / 211.24 5 22
4 13 891.44 20 14.57 1453 423 2.73 / 211.67 5 27
5 13 261.76 20 14.77 661 195 2.92 / 211.86 5 26
6 13 65.04 20 14.84 385 114 3.04 / 211.98 5 22
7 8 0.12 263 14.82 290 1130 4.17 / 213.11 5 162
Average= 4.10
(KJ/cycle)

Cycle 50 GMT 10/ 2/2024 21:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 17 14.81 425 107 0.11 / 204.93 6 6
2 7 2013.08 40 14.42 2694 1554 1.66 / 206.49 6 17
3 13 1437.16 20 14.49 2083 604 2.26 / 207.09 5 23
4 13 918.80 20 14.57 1477 430 2.69 / 207.52 5 26
5 13 246.48 20 14.78 634 187 2.88 / 207.71 5 27
6 13 58.48 20 14.85 372 110 2.99 / 207.82 5 21
7 8 0.16 263 14.82 288 1123 4.12 / 208.94 5 213
Average= 4.10
(KJ/cycle)

Cycle 49 GMT 5/ 2/2024 20:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 17 14.82 449 113 0.11 / 200.71 6 6
2 7 2003.64 41 14.42 2674 1581 1.69 / 202.29 6 17
3 13 1532.44 20 14.47 2182 631 2.33 / 202.92 5 22
4 13 965.88 20 14.56 1543 449 2.77 / 203.37 5 28
5 13 284.72 20 14.77 686 203 2.98 / 203.57 5 27
6 13 85.64 20 14.84 411 122 3.10 / 203.69 5 21
7 8 0.80 265 14.82 288 1131 4.23 / 204.83 5 -99
Average= 4.10
(KJ/cycle)

Cycle 48 GMT 31/ 1/2024 19:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 17 14.82 439 111 0.11 / 196.54 6 6
2 7 2004.28 40 14.44 2662 1538 1.65 / 198.08 6 16
3 13 1452.92 20 14.48 2093 606 2.25 / 198.69 5 23
4 13 907.88 20 14.58 1476 430 2.68 / 199.12 5 30
5 13 350.68 20 14.75 770 227 2.91 / 199.34 5 29
6 13 103.36 20 14.84 431 128 3.04 / 199.47 5 21
7 8 0.16 265 14.83 286 1124 4.16 / 200.60 5 234
Average= 4.09
(KJ/cycle)

Cycle 47 GMT 26/ 1/2024 19: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 16 14.82 433 103 0.10 / 192.43 6 6
2 7 2010.76 40 14.42 2707 1561 1.66 / 193.99 6 17
3 13 1380.28 20 14.51 1977 574 2.24 / 194.56 5 23
4 13 946.68 20 14.56 1519 442 2.68 / 195.01 5 28
5 13 260.20 20 14.79 645 191 2.87 / 195.20 5 24
6 13 104.92 20 14.84 431 128 3.00 / 195.32 5 22
7 8 -0.08 263 14.83 284 1108 4.11 / 196.43 5 212
Average= 4.09
(KJ/cycle)

Cycle 46 GMT 21/ 1/2024 18:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 16 14.83 433 103 0.10 / 188.20 6 6
2 7 2007.84 40 14.43 2657 1534 1.64 / 189.73 6 17
3 13 1515.48 20 14.47 2173 629 2.27 / 190.36 5 20
4 13 1062.68 20 14.54 1649 480 2.74 / 190.84 5 28
5 13 335.00 20 14.76 749 221 2.97 / 191.06 5 24
6 13 124.08 20 14.83 462 137 3.10 / 191.20 5 23
7 8 0.12 265 14.83 286 1124 4.23 / 192.32 5 229
Average= 4.09
(KJ/cycle)

Cycle 45 GMT 16/ 1/2024 17:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 16 14.83 442 105 0.10 / 184.07 6 6
2 7 2007.96 40 14.44 2630 1519 1.62 / 185.59 6 14
3 13 1468.72 20 14.50 2079 603 2.23 / 186.20 5 23
4 13 987.60 20 14.56 1564 455 2.68 / 186.65 5 26
5 13 278.72 20 14.78 676 200 2.88 / 186.85 5 26
6 13 117.08 20 14.84 449 133 3.02 / 186.99 5 21
7 8 0.16 265 14.84 283 1113 4.13 / 188.10 5 229
Average= 4.09
(KJ/cycle)

Cycle 44 GMT 11/ 1/2024 16:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.28 16 14.84 441 105 0.10 / 179.87 6 6
2 7 2005.44 40 14.44 2661 1537 1.64 / 181.41 6 17
3 13 1581.36 20 14.46 2250 651 2.29 / 182.06 5 22
4 13 966.16 20 14.57 1549 451 2.74 / 182.51 5 28
5 13 289.08 20 14.78 690 204 2.95 / 182.72 5 25
6 13 126.08 20 14.84 464 138 3.09 / 182.85 5 23
7 8 0.00 263 14.84 286 1116 4.20 / 183.97 5 147
Average= 4.09
(KJ/cycle)

Cycle 43 GMT 6/ 1/2024 16: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 16 14.84 414 98 0.10 / 175.71 6 6
2 7 2009.32 40 14.47 2644 1530 1.63 / 177.24 6 15
3 13 1507.44 20 14.49 2130 617 2.25 / 177.86 5 20
4 13 983.88 20 14.57 1564 456 2.70 / 178.31 5 26
5 13 272.52 20 14.80 663 196 2.90 / 178.51 5 26
6 13 116.48 20 14.84 457 136 3.03 / 178.64 5 21
7 8 0.00 265 14.84 286 1125 4.16 / 179.77 5 174
Average= 4.09
(KJ/cycle)

Cycle 42 GMT 1/ 1/2024 15:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 16 14.83 417 99 0.10 / 171.56 6 6
2 7 2013.16 40 14.45 2683 1551 1.65 / 173.11 6 15
3 13 1506.52 20 14.51 2109 612 2.26 / 173.72 5 23
4 13 946.32 20 14.59 1511 441 2.70 / 174.16 5 28
5 13 279.88 20 14.79 677 200 2.90 / 174.36 5 27
6 13 113.04 20 14.85 446 132 3.04 / 174.50 5 22
7 8 0.20 265 14.84 283 1113 4.15 / 175.61 5 248
Average= 4.08
(KJ/cycle)

Cycle 41 GMT 27/12/2023 14:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 16 14.84 416 99 0.10 / 167.43 6 6
2 7 2010.32 40 14.43 2698 1557 1.66 / 168.99 6 17
3 13 1421.04 20 14.50 2082 604 2.26 / 169.60 5 25
4 13 877.44 20 14.60 1441 421 2.68 / 170.02 5 28
5 13 272.24 20 14.79 670 198 2.88 / 170.21 5 26
6 13 104.48 20 14.85 439 130 3.01 / 170.35 5 23
7 8 0.00 263 14.84 286 1116 4.13 / 171.46 5 -99
Average= 4.08
(KJ/cycle)

Cycle 40 GMT 22/12/2023 13:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 16 14.84 416 99 0.10 / 163.30 6 6
2 7 2009.16 41 14.45 2637 1562 1.66 / 164.86 6 20
3 13 1466.72 20 14.50 2104 610 2.27 / 165.47 5 25
4 13 877.88 20 14.60 1435 419 2.69 / 165.89 5 29
5 13 250.08 20 14.80 645 191 2.88 / 166.08 5 26
6 13 89.60 20 14.85 420 125 3.01 / 166.20 5 25
7 8 0.20 263 14.84 290 1132 4.14 / 167.34 5 162
Average= 4.08
(KJ/cycle)

Cycle 39 GMT 17/12/2023 13: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 16 14.83 435 103 0.10 / 159.11 6 6
2 7 2004.12 40 14.44 2698 1558 1.66 / 160.66 6 16
3 13 1499.60 20 14.50 2133 619 2.28 / 161.28 5 23
4 13 940.72 20 14.58 1521 444 2.72 / 161.73 5 25
5 13 303.44 20 14.78 717 212 2.94 / 161.94 5 29
6 13 98.36 20 14.85 431 128 3.06 / 162.07 5 28
7 8 0.00 263 14.84 290 1132 4.20 / 163.20 5 183
Average= 4.08
(KJ/cycle)

Cycle 38 GMT 12/12/2023 12: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 16 14.84 414 98 0.10 / 154.88 6 6
2 7 2010.08 40 14.45 2662 1539 1.64 / 156.42 6 20
3 13 1479.16 20 14.53 2068 601 2.24 / 157.02 5 19
4 13 980.92 20 14.58 1571 458 2.70 / 157.48 5 31
5 13 336.96 20 14.76 765 226 2.92 / 157.70 5 29
6 13 113.64 20 14.83 462 137 3.06 / 157.84 5 29
7 8 0.00 265 14.83 296 1163 4.22 / 159.00 5 240
Average= 4.08
(KJ/cycle)

Cycle 37 GMT 7/12/2023 11:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 16 14.85 427 101 0.10 / 150.73 6 6
2 7 2007.48 41 14.45 2665 1579 1.68 / 152.31 6 15
3 13 1514.36 20 14.51 2108 612 2.29 / 152.92 5 22
4 13 850.60 20 14.61 1419 415 2.71 / 153.33 5 27
5 13 270.00 20 14.79 669 198 2.90 / 153.53 5 27
6 13 67.48 20 14.87 388 115 3.02 / 153.65 5 26
7 8 0.08 263 14.85 290 1133 4.15 / 154.78 5 163
Average= 4.07
(KJ/cycle)

Cycle 36 GMT 2/12/2023 10:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 16 14.86 423 101 0.10 / 146.60 6 7
2 7 2011.00 40 14.46 2674 1547 1.65 / 148.15 7 17
3 13 1471.44 20 14.52 2078 603 2.25 / 148.75 5 22
4 13 918.80 20 14.60 1490 435 2.69 / 149.19 5 29
5 13 276.76 20 14.80 675 200 2.89 / 149.39 5 28
6 13 71.56 20 14.87 389 116 3.00 / 149.50 5 24
7 8 0.00 265 14.85 286 1125 4.13 / 150.63 5 223
Average= 4.07
(KJ/cycle)

Cycle 35 GMT 27/11/2023 9:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 16 14.86 416 99 0.10 / 142.46 6 6
2 7 2012.16 40 14.44 2696 1557 1.66 / 144.01 6 17
3 13 1508.72 20 14.50 2186 634 2.29 / 144.65 5 26
4 13 909.44 20 14.61 1471 430 2.72 / 145.08 5 28
5 13 275.36 20 14.80 669 198 2.92 / 145.28 5 27
6 13 73.44 20 14.87 389 116 3.03 / 145.39 5 23
7 8 0.16 265 14.86 282 1110 4.14 / 146.50 5 240
Average= 4.07
(KJ/cycle)

Cycle 34 GMT 22/11/2023 8:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 16 14.87 413 98 0.10 / 138.30 6 6
2 7 2008.32 40 14.44 2672 1543 1.64 / 139.84 6 15
3 13 1540.08 20 14.51 2154 625 2.27 / 140.47 5 19
4 13 914.72 20 14.61 1479 432 2.70 / 140.90 5 27
5 13 291.08 20 14.80 690 204 2.90 / 141.10 5 26
6 13 127.12 20 14.86 460 137 3.04 / 141.24 5 21
7 8 0.20 265 14.86 284 1118 4.16 / 142.36 5 206
Average= 4.07
(KJ/cycle)

Cycle 33 GMT 17/11/2023 8: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 16 14.86 407 97 0.10 / 134.17 6 6
2 7 2009.36 40 14.46 2645 1530 1.63 / 135.70 6 17
3 13 1438.40 20 14.52 2088 606 2.23 / 136.31 5 25
4 13 934.76 20 14.61 1501 439 2.67 / 136.75 5 27
5 13 327.80 20 14.80 736 218 2.89 / 136.96 5 25
6 13 122.96 20 14.86 460 137 3.03 / 137.10 5 20
7 8 -0.04 265 14.87 279 1099 4.13 / 138.20 5 191
Average= 4.06
(KJ/cycle)

Cycle 32 GMT 12/11/2023 7:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 16 14.87 418 99 0.10 / 130.00 6 6
2 7 2007.76 40 14.46 2691 1556 1.66 / 131.55 6 14
3 13 1534.80 20 14.52 2135 620 2.28 / 132.17 5 22
4 13 968.16 20 14.61 1539 450 2.73 / 132.62 5 31
5 13 287.20 20 14.81 686 203 2.93 / 132.83 5 25
6 13 122.96 20 14.87 456 136 3.06 / 132.96 5 21
7 8 0.00 265 14.87 282 1111 4.18 / 134.07 5 228
Average= 4.06
(KJ/cycle)

Cycle 31 GMT 7/11/2023 6:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 16 14.85 437 104 0.10 / 125.83 6 6
2 7 2004.12 41 14.47 2678 1589 1.69 / 127.42 6 17
3 13 1423.80 20 14.54 2047 595 2.29 / 128.01 5 24
4 13 945.00 20 14.61 1525 446 2.73 / 128.46 5 28
5 13 260.88 20 14.82 651 193 2.93 / 128.65 5 26
6 13 105.20 20 14.88 435 129 3.06 / 128.78 5 23
7 8 0.12 265 14.87 283 1115 4.17 / 129.90 5 248
Average= 4.06
(KJ/cycle)

Cycle 30 GMT 2/11/2023 5:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 16 14.86 438 104 0.10 / 121.64 6 6
2 7 2008.28 41 14.47 2660 1578 1.68 / 123.22 6 14
3 13 1449.16 20 14.52 2114 614 2.30 / 123.83 5 19
4 13 933.64 20 14.61 1510 441 2.74 / 124.27 5 30
5 13 285.24 20 14.81 690 204 2.94 / 124.48 5 26
6 13 72.36 20 14.88 397 118 3.06 / 124.59 5 26
7 8 0.12 263 14.86 290 1133 4.19 / 125.73 5 165
Average= 4.06
(KJ/cycle)

Cycle 29 GMT 28/10/2023 4:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 16 14.85 427 101 0.10 / 117.42 6 6
2 7 2006.96 40 14.47 2704 1565 1.67 / 118.98 6 15
3 13 1538.32 20 14.51 2203 639 2.31 / 119.62 5 23
4 13 941.84 20 14.61 1522 445 2.75 / 120.07 5 29
5 13 267.24 20 14.81 669 198 2.95 / 120.27 5 29
6 13 57.08 20 14.89 379 113 3.06 / 120.38 5 28
7 8 0.16 265 14.86 293 1154 4.22 / 121.53 5 -99
Average= 4.05
(KJ/cycle)

Cycle 28 GMT 23/10/2023 4: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 16 14.87 427 102 0.10 / 113.25 6 6
2 7 2004.84 40 14.47 2709 1568 1.67 / 114.82 6 21
3 13 1498.32 20 14.54 2126 618 2.29 / 115.43 5 20
4 13 897.44 20 14.63 1469 430 2.72 / 115.86 5 28
5 13 266.92 20 14.81 666 197 2.91 / 116.06 5 31
6 13 23.40 20 14.90 339 101 3.02 / 116.16 5 29
7 8 -0.12 261 14.86 298 1156 4.17 / 117.32 5 156
Average= 4.05
(KJ/cycle)

Cycle 27 GMT 18/10/2023 3:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 16 14.88 409 97 0.10 / 109.15 6 6
2 7 2012.24 40 14.47 2701 1563 1.66 / 110.71 6 16
3 13 1450.80 20 14.55 2041 594 2.25 / 111.31 5 26
4 13 858.16 20 14.63 1425 417 2.67 / 111.73 5 26
5 13 203.44 20 14.84 584 173 2.84 / 111.90 5 26
6 13 27.04 20 14.90 332 99 2.94 / 112.00 5 22
7 8 0.04 263 14.86 294 1149 4.09 / 113.15 5 237
Average= 4.04
(KJ/cycle)

Cycle 26 GMT 13/10/2023 2:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 16 14.89 416 99 0.10 / 104.96 6 6
2 7 2003.08 41 14.47 2672 1585 1.68 / 106.54 6 19
3 13 1503.96 20 14.54 2132 620 2.30 / 107.16 5 21
4 13 936.56 20 14.62 1507 441 2.74 / 107.61 5 27
5 13 291.04 20 14.82 697 207 2.95 / 107.81 5 28
6 13 86.52 20 14.89 411 122 3.07 / 107.93 5 26
7 8 0.08 263 14.88 286 1119 4.19 / 109.05 5 169
Average= 4.04
(KJ/cycle)

Cycle 25 GMT 8/10/2023 1:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 16 14.89 405 96 0.10 / 100.81 6 6
2 7 2003.52 40 14.48 2693 1560 1.66 / 102.37 6 19
3 13 1457.28 20 14.55 2085 607 2.26 / 102.98 5 18
4 13 913.04 20 14.63 1489 436 2.70 / 103.41 5 27
5 13 278.36 20 14.83 676 201 2.90 / 103.61 5 21
6 13 117.24 20 14.88 450 134 3.03 / 103.75 5 22
7 8 0.16 265 14.89 282 1113 4.15 / 104.86 5 -99
Average= 4.03
(KJ/cycle)

Cycle 24 GMT 3/10/2023 0:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 16 14.87 417 99 0.10 / 96.63 6 6
2 7 2009.44 41 14.49 2657 1578 1.68 / 98.21 6 13
3 13 1470.00 20 14.55 2074 604 2.28 / 98.82 5 17
4 13 924.72 20 14.63 1498 438 2.72 / 99.25 5 26
5 13 290.60 20 14.82 695 206 2.93 / 99.46 5 27
6 13 97.12 20 14.89 426 127 3.05 / 99.59 5 24
7 13 15.32 20 14.92 309 92 3.14 / 99.68 5 18
8 8 0.04 244 14.88 285 1035 4.18 / 100.71 5 158
Average= 4.03
(KJ/cycle)

Cycle 23 GMT 27/ 9/2023 23:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 16 14.88 407 97 0.10 / 92.49 6 7
2 7 2009.36 40 14.49 2682 1554 1.65 / 94.04 7 21
3 13 1473.48 20 14.54 2119 616 2.27 / 94.66 5 26
4 13 888.88 20 14.64 1441 422 2.69 / 95.08 5 26
5 13 284.00 20 14.83 688 204 2.89 / 95.29 5 28
6 13 84.00 20 14.89 409 122 3.02 / 95.41 5 24
7 8 0.12 265 14.88 286 1128 4.14 / 96.54 5 232
Average= 4.02
(KJ/cycle)

Cycle 22 GMT 22/ 9/2023 23: 5: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 16 14.89 407 97 0.10 / 88.38 6 6
2 7 2007.60 40 14.48 2663 1542 1.64 / 89.92 6 21
3 13 1427.68 20 14.56 2085 607 2.25 / 90.53 5 24
4 13 905.64 20 14.65 1459 427 2.67 / 90.96 5 28
5 13 329.24 20 14.81 744 220 2.89 / 91.18 5 26
6 13 81.96 20 14.90 401 119 3.01 / 91.30 5 26
7 8 0.08 263 14.89 280 1096 4.11 / 92.39 5 180
Average= 4.02
(KJ/cycle)

Cycle 21 GMT 17/ 9/2023 22:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 16 14.89 410 98 0.10 / 84.24 6 7
2 7 2006.44 40 14.50 2685 1557 1.65 / 85.80 7 19
3 13 1453.92 20 14.56 2113 615 2.27 / 86.41 5 25
4 13 904.68 20 14.64 1475 432 2.70 / 86.84 5 30
5 13 269.44 20 14.84 669 199 2.90 / 87.04 5 27
6 13 106.84 20 14.89 440 131 3.03 / 87.17 5 18
7 8 0.12 263 14.89 283 1108 4.14 / 88.28 5 137
Average= 4.01
(KJ/cycle)

Cycle 20 GMT 12/ 9/2023 21:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 16 14.90 407 97 0.10 / 80.11 6 6
2 7 2007.24 40 14.50 2668 1547 1.64 / 81.66 6 20
3 13 1482.88 20 14.55 2133 621 2.27 / 82.28 5 21
4 13 873.00 20 14.66 1423 417 2.68 / 82.70 5 25
5 13 256.60 20 14.84 652 194 2.88 / 82.89 5 23
6 13 95.60 20 14.89 426 127 3.00 / 83.02 5 21
7 8 0.12 263 14.89 287 1124 4.13 / 84.14 5 172
Average= 4.01
(KJ/cycle)

Cycle 19 GMT 7/ 9/2023 20:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 16 14.88 428 102 0.10 / 76.01 6 6
2 7 2003.76 40 14.51 2692 1562 1.66 / 77.57 6 13
3 13 1419.32 20 14.57 2052 598 2.26 / 78.17 5 19
4 13 904.68 20 14.65 1461 428 2.69 / 78.60 5 25
5 13 246.80 20 14.85 637 189 2.88 / 78.78 5 32
6 13 86.76 20 14.90 412 123 3.00 / 78.91 5 29
7 8 0.08 261 14.89 285 1108 4.11 / 80.02 5 181
Average= 4.00
(KJ/cycle)

Cycle 18 GMT 2/ 9/2023 19:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 16 14.89 420 100 0.10 / 71.82 6 6
2 7 2011.08 40 14.53 2637 1533 1.63 / 73.35 6 19
3 13 1487.96 20 14.59 2067 603 2.24 / 73.95 5 15
4 13 995.16 20 14.62 1595 466 2.70 / 74.42 5 24
5 13 300.16 20 14.82 712 211 2.91 / 74.63 5 27
6 13 48.88 20 14.91 370 110 3.02 / 74.74 5 26
7 13 18.80 20 14.92 326 97 3.12 / 74.84 5 25
8 8 0.04 242 14.88 296 1066 4.19 / 75.91 5 169
Average= 4.00
(KJ/cycle)

Cycle 17 GMT 28/ 8/2023 18:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 16 14.90 404 96 0.10 / 67.65 6 6
2 7 2010.16 40 14.52 2682 1558 1.65 / 69.21 6 15
3 13 1522.52 20 14.57 2142 624 2.28 / 69.83 5 20
4 13 914.00 20 14.65 1485 435 2.71 / 70.27 5 26
5 13 243.76 20 14.84 640 190 2.90 / 70.46 5 32
6 13 38.96 20 14.92 353 105 3.01 / 70.56 5 26
7 8 -0.08 263 14.89 295 1155 4.16 / 71.72 5 183
Average= 3.98
(KJ/cycle)

Cycle 16 GMT 23/ 8/2023 18:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 16 14.91 408 97 0.10 / 63.48 6 6
2 7 2009.00 41 14.50 2715 1614 1.71 / 65.10 6 14
3 13 1461.68 20 14.58 2118 618 2.33 / 65.72 5 21
4 13 867.32 20 14.67 1419 416 2.75 / 66.13 5 28
5 13 232.72 20 14.86 622 185 2.93 / 66.32 5 30
6 13 73.00 20 14.91 395 118 3.05 / 66.43 5 25
7 8 -0.04 261 14.90 288 1120 4.17 / 67.55 5 170
Average= 3.97
(KJ/cycle)

Cycle 15 GMT 18/ 8/2023 17:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 16 14.91 411 98 0.10 / 59.45 6 6
2 7 2008.88 40 14.52 2668 1550 1.65 / 61.00 6 15
3 13 1400.84 20 14.61 1981 579 2.23 / 61.57 5 26
4 13 859.88 20 14.66 1428 419 2.65 / 61.99 5 28
5 13 232.76 20 14.87 614 183 2.83 / 62.18 5 24
6 13 86.36 20 14.92 406 121 2.95 / 62.30 5 24
7 8 0.16 261 14.91 280 1090 4.04 / 63.39 5 196
Average= 3.96
(KJ/cycle)

Cycle 14 GMT 13/ 8/2023 16:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 16 14.90 410 98 0.10 / 55.33 6 6
2 7 2004.32 40 14.52 2675 1554 1.65 / 56.88 6 18
3 13 1489.40 20 14.60 2096 612 2.26 / 57.49 5 24
4 13 892.60 20 14.67 1457 427 2.69 / 57.92 5 30
5 13 252.76 20 14.87 642 191 2.88 / 58.11 5 22
6 13 106.20 20 14.92 433 129 3.01 / 58.24 5 23
7 13 16.00 20 14.95 305 91 3.10 / 58.33 5 17
8 8 0.08 242 14.91 282 1018 4.12 / 59.35 5 199
Average= 3.96
(KJ/cycle)

Cycle 13 GMT 8/ 8/2023 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 16 14.91 409 98 0.10 / 51.20 6 6
2 7 2008.44 41 14.53 2651 1579 1.68 / 52.77 6 13
3 13 1492.88 20 14.58 2137 623 2.30 / 53.40 5 24
4 13 893.60 20 14.67 1450 425 2.73 / 53.82 5 26
5 13 252.64 20 14.87 637 189 2.91 / 54.01 5 25
6 13 97.92 20 14.92 421 126 3.04 / 54.14 5 24
7 8 0.16 261 14.91 280 1090 4.13 / 55.23 5 171
Average= 3.94
(KJ/cycle)

Cycle 12 GMT 3/ 8/2023 14:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 16 14.91 405 97 0.10 / 47.04 6 6
2 7 2003.88 40 14.52 2746 1595 1.69 / 48.64 6 22
3 13 1450.24 20 14.61 2048 598 2.29 / 49.24 5 24
4 13 898.12 20 14.67 1463 429 2.72 / 49.67 5 29
5 13 262.08 20 14.86 655 195 2.91 / 49.86 5 26
6 13 98.48 20 14.92 425 127 3.04 / 49.99 5 24
7 8 -0.04 263 14.91 283 1110 4.15 / 51.10 5 -99
Average= 3.93
(KJ/cycle)

Cycle 11 GMT 29/ 7/2023 13:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 16 14.90 427 102 0.10 / 42.97 6 6
2 7 2007.48 40 14.53 2681 1558 1.66 / 44.53 6 14
3 13 1457.76 20 14.58 2107 614 2.27 / 45.15 5 23
4 13 818.04 20 14.69 1367 402 2.68 / 45.55 5 31
5 13 223.60 20 14.88 602 179 2.86 / 45.73 5 31
6 13 70.08 20 14.93 386 115 2.97 / 45.84 5 27
7 8 0.12 261 14.91 284 1105 4.08 / 46.95 5 -99
Average= 3.91
(KJ/cycle)

Cycle 10 GMT 24/ 7/2023 13: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 16 14.90 409 98 0.10 / 38.81 6 6
2 7 2004.76 40 14.54 2678 1558 1.66 / 40.37 6 14
3 13 1459.88 20 14.59 2099 612 2.27 / 40.98 5 21
4 13 933.36 20 14.67 1501 440 2.71 / 41.42 5 28
5 13 267.04 20 14.85 670 199 2.91 / 41.62 5 29
6 13 57.88 20 14.92 378 113 3.02 / 41.73 5 31
7 8 0.08 263 14.90 291 1140 4.16 / 42.87 5 -99
Average= 3.90
(KJ/cycle)

Cycle 9 GMT 19/ 7/2023 12:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 16 14.92 404 96 0.10 / 34.75 6 6
2 7 2003.12 40 14.53 2666 1549 1.65 / 36.30 6 14
3 13 1412.12 20 14.61 2018 590 2.24 / 36.89 5 23
4 13 843.16 20 14.69 1384 407 2.64 / 37.29 5 25
5 13 242.52 20 14.86 636 189 2.83 / 37.48 5 31
6 13 84.04 20 14.92 407 121 2.95 / 37.60 5 31
7 8 0.08 261 14.90 285 1108 4.06 / 38.71 5 194
Average= 3.87
(KJ/cycle)

Cycle 8 GMT 14/ 7/2023 11:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 16 14.93 402 96 0.10 / 30.61 6 6
2 7 2011.20 40 14.53 2737 1591 1.69 / 32.20 6 18
3 13 1384.64 20 14.60 2048 598 2.28 / 32.80 5 19
4 13 941.64 20 14.67 1516 445 2.73 / 33.25 5 25
5 13 278.92 20 14.87 669 199 2.93 / 33.45 5 22
6 13 133.28 20 14.92 459 137 3.07 / 33.58 5 21
7 8 0.08 261 14.93 274 1068 4.13 / 34.65 5 229
Average= 3.85
(KJ/cycle)

Cycle 7 GMT 9/ 7/2023 10:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 16 14.91 409 98 0.10 / 26.48 6 6
2 7 2011.64 40 14.55 2681 1560 1.66 / 28.04 6 15
3 13 1499.76 20 14.60 2152 628 2.29 / 28.67 5 17
4 13 929.24 20 14.67 1501 440 2.73 / 29.11 5 31
5 13 274.56 20 14.88 664 198 2.92 / 29.31 5 24
6 13 124.20 20 14.92 452 135 3.06 / 29.45 5 21
7 8 0.00 261 14.93 275 1072 4.13 / 30.52 5 180
Average= 3.81
(KJ/cycle)

Cycle 6 GMT 4/ 7/2023 10: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 16 14.92 410 98 0.10 / 22.29 6 6
2 7 2003.16 40 14.56 2635 1535 1.63 / 23.82 6 17
3 13 1468.44 20 14.60 2105 615 2.25 / 24.44 5 20
4 13 913.48 20 14.68 1483 435 2.68 / 24.87 5 30
5 13 417.36 20 14.81 863 256 2.94 / 25.13 5 34
6 13 108.48 20 14.92 438 131 3.07 / 25.26 5 25
7 13 33.88 20 14.94 332 99 3.17 / 25.36 5 23
8 8 0.08 244 14.91 283 1030 4.20 / 26.39 5 -99
Average= 3.77
(KJ/cycle)

Cycle 5 GMT 29/ 6/2023 9:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 16 14.92 410 98 0.10 / 18.15 6 6
2 7 2009.16 40 14.55 2668 1553 1.65 / 19.71 6 17
3 13 1507.56 20 14.60 2108 616 2.27 / 20.32 5 24
4 13 974.96 20 14.67 1544 453 2.72 / 20.77 5 24
5 13 259.56 20 14.88 643 191 2.91 / 20.97 5 21
6 13 106.68 20 14.93 431 129 3.04 / 21.09 5 20
7 8 0.08 263 14.93 279 1096 4.13 / 22.19 5 -99
Average= 3.70
(KJ/cycle)

Cycle 4 GMT 24/ 6/2023 8:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 16 14.90 424 101 0.10 / 14.01 6 6
2 7 2010.52 40 14.55 2715 1580 1.68 / 15.59 6 11
3 13 1478.84 20 14.61 2115 618 2.30 / 16.20 5 26
4 13 892.40 20 14.69 1461 429 2.73 / 16.63 5 22
5 13 322.72 20 14.86 726 216 2.94 / 16.85 5 19
6 13 125.88 20 14.92 452 135 3.08 / 16.98 5 26
7 8 0.12 261 14.93 275 1072 4.15 / 18.05 5 -99
Average= 3.61
(KJ/cycle)

Cycle 3 GMT 19/ 6/2023 7:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 16 14.91 402 96 0.10 / 9.91 6 6
2 7 2010.20 40 14.57 2643 1540 1.64 / 11.45 6 18
3 13 1448.08 20 14.61 2099 613 2.25 / 12.06 5 24
4 13 894.00 20 14.69 1459 429 2.68 / 12.49 5 27
5 13 237.60 20 14.88 619 184 2.86 / 12.67 5 31
6 13 71.80 20 14.93 387 116 2.98 / 12.79 5 29
7 8 0.00 263 14.91 284 1114 4.09 / 13.90 5 -99
Average= 3.48
(KJ/cycle)

Cycle 2 GMT 14/ 6/2023 6:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 14 14.88 396 82 0.08 / 5.73 6 6
2 10 1501.08 3 14.69 2165 95 0.18 / 5.82 5 8
3 7 2010.32 40 14.56 2703 1574 1.75 / 7.40 8 12
4 13 1463.72 20 14.62 2104 615 2.37 / 8.01 5 22
5 13 869.48 20 14.70 1410 415 2.78 / 8.43 5 26
6 13 261.88 20 14.87 645 192 2.97 / 8.62 5 20
7 13 80.28 20 14.94 389 116 3.09 / 8.73 5 22
8 8 0.12 263 14.92 275 1079 4.17 / 9.81 5 -99
Average= 3.27
(KJ/cycle)

Cycle 1 GMT 9/ 6/2023 5:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 18 15.06 408 111 0.11 / 1.71 6 6
2 3 1363.92 -2 15.32 0 0 0.00 / 1.71 6 6
3 7 2003.32 40 14.57 2643 1540 1.65 / 3.25 6 14
4 13 1434.36 20 14.61 2023 591 2.24 / 3.84 5 25
5 13 884.56 20 14.68 1433 421 2.66 / 4.26 5 33
6 13 209.32 20 14.87 575 171 2.83 / 4.43 5 23
7 13 93.40 20 14.90 414 123 2.96 / 4.55 5 24
8 8 0.08 265 14.89 276 1089 4.05 / 5.64 5 -99
Average= 2.82
(KJ/cycle)

Cycle 0 GMT 4/ 6/2023 4:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 80.68 18 15.23 368 101 0.10 / 0.10 6 7
2 7 95.76 40 15.21 387 235 0.34 / 0.34 7 8
3 13 125.72 20 15.19 419 127 0.46 / 0.46 6 9
4 13 102.56 20 15.18 389 118 0.58 / 0.58 6 14
5 8 0.08 267 15.15 251 1015 1.60 / 1.60 6 -99
Average= 1.60
(KJ/cycle)