SIO Argo Site:
Pump Diagnostics Page   



Serial= 7802 WMO= 4903548

Return

←PreviousNext→

Cycle 69 GMT 16/ 5/2024 22:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 17 15.12 413 106 0.11 / 292.57 5 6
2 7 2006.88 40 14.73 3048 1796 1.90 / 294.37 6 13
3 13 1408.20 20 14.81 2241 664 2.57 / 295.03 5 19
4 13 826.40 20 14.92 1451 433 3.00 / 295.46 5 25
5 13 147.28 20 15.12 488 148 3.15 / 295.61 5 21
6 8 -0.04 293 15.11 268 1186 4.33 / 296.80 5 134
Average= 4.24
(KJ/cycle)

Cycle 68 GMT 11/ 5/2024 21:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 17 15.12 408 105 0.10 / 288.26 5 6
2 7 2015.08 41 14.72 3059 1846 1.95 / 290.11 6 13
3 13 1366.24 20 14.83 2184 648 2.60 / 290.75 5 20
4 13 727.80 20 14.96 1313 393 2.99 / 291.15 5 24
5 13 180.60 20 15.12 528 160 3.15 / 291.31 5 18
6 8 0.08 295 15.12 260 1160 4.31 / 292.47 5 150
Average= 4.24
(KJ/cycle)

Cycle 67 GMT 6/ 5/2024 20:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 17 15.11 405 104 0.10 / 283.97 5 6
2 7 2010.84 40 14.73 3058 1802 1.91 / 285.77 6 13
3 13 1395.00 20 14.83 2224 660 2.57 / 286.43 5 19
4 13 753.88 20 14.95 1345 402 2.97 / 286.83 5 25
5 13 169.16 20 15.12 518 157 3.12 / 286.99 5 20
6 8 0.12 293 15.12 263 1165 4.29 / 288.15 5 137
Average= 4.24
(KJ/cycle)

Cycle 66 GMT 1/ 5/2024 20:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 17 15.11 414 106 0.11 / 279.68 5 6
2 7 2012.80 41 14.73 3049 1841 1.95 / 281.52 6 13
3 13 1338.28 20 14.84 2154 639 2.59 / 282.16 5 20
4 13 699.88 20 14.97 1276 382 2.97 / 282.54 5 25
5 13 119.40 20 15.14 444 134 3.10 / 282.67 5 20
6 8 0.00 293 15.11 269 1191 4.29 / 283.86 5 144
Average= 4.24
(KJ/cycle)

Cycle 65 GMT 26/ 4/2024 19:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 17 15.11 412 106 0.11 / 275.36 5 6
2 7 2012.16 41 14.74 3047 1841 1.95 / 277.21 6 13
3 13 1331.96 20 14.84 2144 636 2.58 / 277.84 5 20
4 13 696.44 20 14.98 1269 380 2.96 / 278.22 5 25
5 13 182.52 20 15.12 546 165 3.13 / 278.39 5 24
6 8 0.56 291 15.11 269 1183 4.31 / 279.57 5 137
Average= 4.24
(KJ/cycle)

Cycle 64 GMT 21/ 4/2024 18:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 17 15.13 409 105 0.11 / 271.04 5 6
2 7 2007.28 41 14.74 3051 1844 1.95 / 272.88 6 13
3 13 1354.60 20 14.84 2173 645 2.59 / 273.53 5 20
4 13 749.24 20 14.96 1345 402 3.00 / 273.93 5 24
5 13 106.28 20 15.14 433 131 3.13 / 274.06 5 20
6 8 -0.04 291 15.12 272 1197 4.32 / 275.26 5 133
Average= 4.23
(KJ/cycle)

Cycle 63 GMT 16/ 4/2024 18:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 17 15.13 412 106 0.11 / 266.74 5 6
2 7 2003.92 40 14.74 3042 1794 1.90 / 268.53 6 13
3 13 1421.12 20 14.83 2255 669 2.57 / 269.20 5 19
4 13 757.04 20 14.97 1352 405 2.97 / 269.60 5 24
5 13 203.40 20 15.13 564 171 3.14 / 269.77 5 19
6 8 0.16 293 15.13 262 1161 4.31 / 270.93 5 142
Average= 4.23
(KJ/cycle)

Cycle 62 GMT 11/ 4/2024 17:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.64 17 15.13 416 107 0.11 / 262.48 5 6
2 7 2006.76 40 14.74 3028 1785 1.89 / 264.27 6 13
3 13 1354.96 20 14.85 2172 645 2.54 / 264.92 5 19
4 13 776.64 20 14.96 1372 411 2.95 / 265.33 5 24
5 13 176.96 20 15.14 525 159 3.11 / 265.48 5 17
6 8 0.08 293 15.14 258 1144 4.25 / 266.63 5 142
Average= 4.23
(KJ/cycle)

Cycle 61 GMT 6/ 4/2024 17:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 17 15.13 403 104 0.10 / 258.23 5 6
2 7 2007.16 40 14.75 3037 1792 1.90 / 260.02 6 13
3 13 1298.68 20 14.87 2091 622 2.52 / 260.64 5 20
4 13 773.60 20 14.97 1373 411 2.93 / 261.05 5 25
5 13 176.76 20 15.14 521 158 3.09 / 261.21 5 19
6 8 0.20 295 15.14 261 1166 4.25 / 262.38 5 155
Average= 4.23
(KJ/cycle)

Cycle 60 GMT 1/ 4/2024 16:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 17 15.12 413 106 0.11 / 253.94 5 6
2 7 2015.36 41 14.75 3044 1841 1.95 / 255.78 6 13
3 13 1299.32 20 14.87 2084 620 2.57 / 256.40 5 20
4 13 771.84 20 14.97 1366 409 2.98 / 256.81 5 25
5 13 103.76 20 15.16 424 129 3.10 / 256.94 5 20
6 8 0.24 291 15.13 270 1189 4.29 / 258.13 5 134
Average= 4.23
(KJ/cycle)

Cycle 59 GMT 27/ 3/2024 15:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 17 15.13 399 103 0.10 / 249.69 5 6
2 7 2011.20 40 14.75 3035 1791 1.89 / 251.48 6 13
3 13 1323.40 20 14.86 2126 632 2.53 / 252.11 5 20
4 13 769.72 20 14.97 1366 409 2.93 / 252.52 5 25
5 13 84.20 20 15.16 400 121 3.06 / 252.64 5 23
6 8 0.00 291 15.13 271 1193 4.25 / 253.83 5 139
Average= 4.23
(KJ/cycle)

Cycle 58 GMT 22/ 3/2024 15:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 17 15.13 408 105 0.10 / 245.48 5 6
2 7 2008.12 40 14.76 3028 1788 1.89 / 247.27 6 13
3 13 1365.88 20 14.86 2175 646 2.54 / 247.92 5 19
4 13 680.64 20 15.00 1239 372 2.91 / 248.29 5 25
5 13 92.24 20 15.17 399 121 3.03 / 248.41 5 20
6 8 0.08 293 15.14 265 1176 4.21 / 249.58 5 144
Average= 4.23
(KJ/cycle)

Cycle 57 GMT 17/ 3/2024 14:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 17 15.13 409 105 0.11 / 241.20 5 6
2 7 2013.12 40 14.75 3051 1800 1.91 / 243.00 6 13
3 13 1339.16 20 14.87 2132 634 2.54 / 243.63 5 20
4 13 802.32 20 14.96 1418 424 2.96 / 244.06 5 25
5 13 86.96 20 15.17 405 123 3.09 / 244.18 5 20
6 8 -0.04 293 15.14 270 1198 4.28 / 245.38 5 147
Average= 4.23
(KJ/cycle)

Cycle 56 GMT 12/ 3/2024 14: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 17 15.14 402 103 0.10 / 236.91 5 6
2 7 2009.60 40 14.76 3036 1792 1.90 / 238.70 6 13
3 13 1457.84 20 14.85 2298 683 2.58 / 239.38 5 19
4 13 725.68 20 14.99 1305 391 2.97 / 239.77 5 25
5 13 112.60 20 15.16 436 132 3.10 / 239.90 5 21
6 8 0.16 293 15.14 268 1189 4.29 / 241.09 5 142
Average= 4.23
(KJ/cycle)

Cycle 55 GMT 7/ 3/2024 13:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 17 15.14 407 105 0.10 / 232.62 5 6
2 7 2005.08 40 14.76 3038 1794 1.90 / 234.42 6 13
3 13 1408.56 20 14.86 2237 665 2.56 / 235.08 5 19
4 13 761.12 20 14.98 1356 406 2.97 / 235.49 5 25
5 13 147.80 20 15.16 484 147 3.12 / 235.63 5 21
6 8 -0.04 293 15.15 263 1167 4.28 / 236.80 5 132
Average= 4.23
(KJ/cycle)

Cycle 54 GMT 2/ 3/2024 12:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 17 15.14 410 106 0.11 / 228.30 5 6
2 7 2008.52 40 14.76 3043 1797 1.90 / 230.09 6 13
3 13 1424.16 20 14.86 2248 668 2.57 / 230.76 5 19
4 13 764.52 20 14.99 1357 407 2.98 / 231.17 5 25
5 13 174.32 20 15.15 525 159 3.14 / 231.33 5 22
6 13 17.32 20 15.19 297 90 3.23 / 231.42 5 19
7 8 0.00 272 15.14 267 1100 4.33 / 232.52 5 136
Average= 4.23
(KJ/cycle)

Cycle 53 GMT 26/ 2/2024 12:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 17 15.14 410 106 0.11 / 224.02 5 6
2 7 2004.56 41 14.76 3036 1837 1.94 / 225.85 6 13
3 13 1352.64 20 14.88 2158 642 2.59 / 226.49 5 20
4 13 714.60 20 15.00 1290 387 2.97 / 226.88 5 26
5 13 80.88 20 15.18 396 120 3.09 / 227.00 5 21
6 8 -0.04 291 15.15 270 1190 4.28 / 228.19 5 141
Average= 4.23
(KJ/cycle)

Cycle 52 GMT 21/ 2/2024 11:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 17 15.15 408 105 0.11 / 219.74 5 6
2 7 2009.12 41 14.76 3050 1846 1.95 / 221.59 6 13
3 13 1321.32 20 14.88 2115 629 2.58 / 222.22 5 20
4 13 703.60 20 15.01 1272 382 2.96 / 222.60 5 25
5 13 70.64 20 15.18 379 115 3.08 / 222.72 5 22
6 8 0.12 291 15.14 271 1194 4.27 / 223.91 5 146
Average= 4.22
(KJ/cycle)

Cycle 51 GMT 16/ 2/2024 11: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 17 15.16 400 103 0.10 / 215.48 5 6
2 7 2011.24 40 14.76 3048 1800 1.90 / 217.28 6 13
3 13 1363.44 20 14.87 2177 647 2.55 / 217.93 5 20
4 13 756.76 20 14.99 1355 406 2.96 / 218.34 5 25
5 13 122.44 20 15.17 449 136 3.09 / 218.47 5 20
6 8 0.08 293 15.15 263 1167 4.26 / 219.64 5 139
Average= 4.22
(KJ/cycle)

Cycle 50 GMT 11/ 2/2024 10:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 17 15.15 404 104 0.10 / 211.26 5 6
2 7 2007.60 40 14.76 3036 1792 1.90 / 213.05 6 13
3 13 1333.56 20 14.88 2144 638 2.53 / 213.69 5 19
4 13 732.28 20 15.01 1316 395 2.93 / 214.08 5 24
5 13 145.80 20 15.18 476 145 3.07 / 214.23 5 16
6 13 18.08 20 15.21 286 87 3.16 / 214.32 5 14
7 8 0.12 274 15.16 256 1063 4.22 / 215.38 5 139
Average= 4.22
(KJ/cycle)

Cycle 49 GMT 6/ 2/2024 9:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 17 15.16 410 106 0.11 / 207.00 5 6
2 7 2003.36 40 14.77 3041 1797 1.90 / 208.80 6 13
3 13 1383.76 20 14.87 2190 651 2.55 / 209.45 5 19
4 13 710.20 20 15.01 1283 385 2.94 / 209.84 5 25
5 13 169.40 20 15.16 521 158 3.10 / 209.99 5 21
6 8 0.00 293 15.16 261 1159 4.26 / 211.15 5 140
Average= 4.22
(KJ/cycle)

Cycle 48 GMT 1/ 2/2024 8:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 17 15.17 408 105 0.11 / 202.72 6 6
2 7 2013.72 40 14.76 3051 1801 1.91 / 204.52 6 13
3 13 1377.16 20 14.87 2195 653 2.56 / 205.17 5 19
4 13 763.56 20 15.00 1358 407 2.97 / 205.58 5 24
5 13 165.36 20 15.17 507 154 3.12 / 205.74 5 18
6 13 23.68 20 15.20 300 91 3.21 / 205.83 5 15
7 8 0.08 274 15.16 258 1072 4.28 / 206.90 5 137
Average= 4.22
(KJ/cycle)

Cycle 47 GMT 27/ 1/2024 8:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 17 15.16 394 102 0.10 / 198.46 5 6
2 7 2010.80 40 14.77 3047 1800 1.90 / 200.26 6 13
3 13 1373.56 20 14.88 2184 650 2.55 / 200.91 5 19
4 13 771.16 20 15.00 1364 409 2.96 / 201.32 5 24
5 13 180.32 20 15.17 525 159 3.12 / 201.48 5 16
6 8 0.36 295 15.17 254 1137 4.26 / 202.61 5 140
Average= 4.22
(KJ/cycle)

Cycle 46 GMT 22/ 1/2024 7:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 17 15.17 400 103 0.10 / 194.23 5 6
2 7 2010.48 40 14.77 3039 1795 1.90 / 196.02 6 13
3 13 1373.88 20 14.88 2184 650 2.55 / 196.67 5 19
4 13 698.32 20 15.03 1259 378 2.93 / 197.05 5 24
5 13 193.60 20 15.17 540 164 3.09 / 197.21 5 17
6 13 45.76 20 15.21 320 97 3.19 / 197.31 5 14
7 8 0.12 274 15.17 252 1047 4.24 / 198.36 5 146
Average= 4.22
(KJ/cycle)

Cycle 45 GMT 17/ 1/2024 6:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 17 15.18 404 104 0.10 / 189.96 5 6
2 7 2009.20 40 14.77 3044 1798 1.90 / 191.75 6 13
3 13 1360.44 20 14.89 2166 645 2.55 / 192.40 5 19
4 13 831.00 20 14.99 1452 435 2.98 / 192.83 5 24
5 13 192.32 20 15.17 540 164 3.15 / 193.00 5 17
6 8 0.20 295 15.18 251 1124 4.27 / 194.12 5 149
Average= 4.22
(KJ/cycle)

Cycle 44 GMT 12/ 1/2024 6: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 17 15.18 407 105 0.11 / 185.72 5 6
2 7 2004.64 40 14.79 3029 1792 1.90 / 187.51 6 13
3 13 1409.76 20 14.87 2242 667 2.56 / 188.18 5 19
4 13 739.48 20 15.02 1320 397 2.96 / 188.58 5 24
5 13 172.48 20 15.18 507 154 3.11 / 188.73 5 16
6 13 15.36 20 15.22 275 84 3.20 / 188.82 5 12
7 8 0.00 274 15.18 249 1036 4.23 / 189.85 5 130
Average= 4.22
(KJ/cycle)

Cycle 43 GMT 7/ 1/2024 5:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.64 17 15.18 404 104 0.10 / 181.48 5 6
2 7 2003.88 40 14.78 3034 1794 1.90 / 183.27 6 13
3 13 1376.16 20 14.89 2181 650 2.55 / 183.92 5 19
4 13 809.80 20 15.00 1405 421 2.97 / 184.34 5 24
5 13 182.28 20 15.18 517 157 3.13 / 184.50 5 16
6 8 0.08 295 15.19 250 1120 4.25 / 185.62 5 138
Average= 4.22
(KJ/cycle)

Cycle 42 GMT 2/ 1/2024 4:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.00 17 15.18 403 104 0.10 / 177.25 5 6
2 7 2011.52 40 14.78 3043 1799 1.90 / 179.05 6 13
3 13 1372.64 20 14.89 2176 648 2.55 / 179.69 5 19
4 13 727.68 20 15.03 1298 390 2.94 / 180.08 5 24
5 13 182.60 20 15.18 521 158 3.10 / 180.24 5 16
6 8 0.16 295 15.19 252 1129 4.23 / 181.37 5 143
Average= 4.22
(KJ/cycle)

Cycle 41 GMT 28/12/2023 3:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 16 15.19 403 98 0.10 / 173.00 5 6
2 7 2003.28 40 14.79 3032 1794 1.89 / 174.80 6 13
3 13 1341.68 20 14.90 2147 640 2.53 / 175.44 5 19
4 13 749.48 20 15.02 1334 401 2.93 / 175.84 5 24
5 13 204.92 20 15.18 553 168 3.10 / 176.01 5 16
6 8 0.00 297 15.19 252 1137 4.24 / 177.14 5 149
Average= 4.22
(KJ/cycle)

Cycle 40 GMT 23/12/2023 3:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 16 15.19 391 95 0.10 / 168.74 5 6
2 7 2003.56 41 14.78 3024 1832 1.93 / 170.57 6 13
3 13 1355.84 20 14.90 2165 645 2.57 / 171.22 5 19
4 13 749.16 20 15.02 1335 401 2.97 / 171.62 5 23
5 13 184.28 20 15.19 527 160 3.13 / 171.78 5 16
6 8 0.12 295 15.19 252 1129 4.26 / 172.91 5 151
Average= 4.22
(KJ/cycle)

Cycle 39 GMT 18/12/2023 2:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 16 15.19 384 93 0.09 / 164.44 5 6
2 7 2003.64 40 14.79 3033 1794 1.89 / 166.23 6 13
3 13 1363.84 20 14.90 2171 647 2.53 / 166.88 5 19
4 13 803.84 20 15.01 1405 422 2.96 / 167.30 5 24
5 13 207.52 20 15.18 560 170 3.13 / 167.47 5 17
6 13 67.84 20 15.22 356 108 3.23 / 167.58 5 13
7 8 0.08 276 15.19 254 1065 4.30 / 168.64 5 141
Average= 4.22
(KJ/cycle)

Cycle 38 GMT 13/12/2023 1:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 16 15.19 393 96 0.10 / 160.11 5 6
2 7 2009.88 41 14.79 3041 1844 1.94 / 161.96 6 13
3 13 1475.76 20 14.87 2319 690 2.63 / 162.65 5 18
4 13 715.96 20 15.04 1282 386 3.01 / 163.03 5 23
5 13 178.24 20 15.20 517 157 3.17 / 163.19 5 16
6 13 71.64 20 15.22 359 109 3.28 / 163.30 5 13
7 8 0.20 274 15.19 251 1045 4.33 / 164.34 5 137
Average= 4.21
(KJ/cycle)

Cycle 37 GMT 8/12/2023 1:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 16 15.19 407 99 0.10 / 155.78 6 6
2 7 2007.64 40 14.80 3041 1800 1.90 / 157.59 6 13
3 13 1410.64 20 14.89 2242 668 2.57 / 158.25 5 19
4 13 797.08 20 15.02 1399 420 2.99 / 158.67 5 24
5 13 205.64 20 15.19 558 170 3.16 / 158.84 5 17
6 13 94.48 20 15.21 392 119 3.28 / 158.96 5 14
7 8 0.12 278 15.19 250 1056 4.33 / 160.02 5 151
Average= 4.21
(KJ/cycle)

Cycle 36 GMT 3/12/2023 0:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 16 15.20 383 93 0.09 / 151.46 6 6
2 7 2009.20 40 14.80 3033 1796 1.89 / 153.26 6 13
3 13 1437.36 20 14.89 2276 678 2.57 / 153.94 5 18
4 13 785.64 20 15.02 1382 415 2.98 / 154.35 5 23
5 13 198.04 20 15.20 543 165 3.15 / 154.52 5 16
6 13 89.84 20 15.22 383 117 3.26 / 154.63 5 13
7 8 -0.04 278 15.20 249 1052 4.32 / 155.69 5 147
Average= 4.21
(KJ/cycle)

Cycle 35 GMT 28/11/2023 0: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 16 15.20 377 92 0.09 / 147.21 5 6
2 7 2008.72 40 14.80 3035 1797 1.89 / 149.00 6 13
3 13 1320.92 20 14.91 2128 635 2.52 / 149.64 5 19
4 13 762.96 20 15.04 1345 405 2.93 / 150.04 5 23
5 13 197.72 20 15.19 545 166 3.09 / 150.21 5 17
6 13 88.76 20 15.22 384 117 3.21 / 150.33 5 14
7 8 0.24 274 15.20 251 1045 4.26 / 151.37 5 140
Average= 4.20
(KJ/cycle)

Cycle 34 GMT 22/11/2023 23:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 16 15.20 383 93 0.09 / 142.92 6 6
2 7 2010.48 40 14.80 3038 1798 1.89 / 144.72 6 13
3 13 1359.64 20 14.92 2165 646 2.54 / 145.37 5 19
4 13 788.72 20 15.03 1387 417 2.95 / 145.78 5 23
5 13 197.40 20 15.20 541 164 3.12 / 145.95 5 16
6 13 88.76 20 15.22 381 116 3.24 / 146.06 5 13
7 8 0.12 278 15.20 249 1052 4.29 / 147.12 5 158
Average= 4.20
(KJ/cycle)

Cycle 33 GMT 17/11/2023 22:39:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 16 15.20 407 99 0.10 / 138.63 6 6
2 7 2003.40 40 14.80 3029 1793 1.89 / 140.43 6 13
3 13 1345.44 20 14.92 2144 640 2.53 / 141.07 5 19
4 13 780.20 20 15.04 1363 410 2.94 / 141.48 5 23
5 13 214.08 20 15.20 571 174 3.12 / 141.65 5 17
6 13 100.68 20 15.22 399 121 3.24 / 141.77 5 14
7 8 -0.04 276 15.20 252 1057 4.29 / 142.83 5 136
Average= 4.20
(KJ/cycle)

Cycle 32 GMT 12/11/2023 22: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 16 15.20 384 93 0.09 / 134.34 6 6
2 7 2005.24 40 14.81 3025 1792 1.89 / 136.13 6 13
3 13 1367.76 20 14.92 2182 651 2.54 / 136.78 5 19
4 13 796.20 20 15.03 1397 420 2.96 / 137.20 5 24
5 13 206.96 20 15.20 561 171 3.13 / 137.37 5 16
6 13 97.88 20 15.22 395 120 3.25 / 137.49 5 14
7 8 0.04 276 15.20 249 1045 4.29 / 138.53 5 133
Average= 4.20
(KJ/cycle)

Cycle 31 GMT 7/11/2023 21:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.08 16 15.21 404 98 0.10 / 130.04 6 6
2 7 2010.96 40 14.81 3041 1801 1.90 / 131.84 6 13
3 13 1338.48 20 14.93 2130 636 2.54 / 132.48 5 19
4 13 787.84 20 15.04 1384 416 2.95 / 132.89 5 23
5 13 227.56 20 15.19 586 178 3.13 / 133.07 5 17
6 13 83.24 20 15.23 374 114 3.24 / 133.18 5 13
7 8 0.00 278 15.21 250 1057 4.30 / 134.24 5 148
Average= 4.20
(KJ/cycle)

Cycle 30 GMT 2/11/2023 20:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 16 15.21 405 99 0.10 / 125.75 6 6
2 7 2003.32 41 14.82 3028 1840 1.94 / 127.59 6 13
3 13 1372.84 20 14.93 2178 650 2.59 / 128.24 5 19
4 13 698.16 20 15.07 1257 379 2.97 / 128.62 5 23
5 13 192.68 20 15.21 538 164 3.13 / 128.78 5 16
6 13 84.96 20 15.23 378 115 3.25 / 128.90 5 14
7 8 0.08 276 15.21 249 1045 4.29 / 129.94 5 137
Average= 4.19
(KJ/cycle)

Cycle 29 GMT 28/10/2023 19:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.16 16 15.21 403 98 0.10 / 121.48 6 6
2 7 2013.96 40 14.82 3034 1799 1.90 / 123.28 6 12
3 13 1345.08 20 14.94 2142 640 2.54 / 123.92 5 19
4 13 778.28 20 15.05 1364 411 2.95 / 124.33 5 23
5 13 189.56 20 15.21 534 162 3.11 / 124.49 5 16
6 13 82.84 20 15.24 374 114 3.22 / 124.60 5 14
7 8 0.04 276 15.21 249 1045 4.27 / 125.65 5 134
Average= 4.19
(KJ/cycle)

Cycle 28 GMT 23/10/2023 18:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 16 15.21 381 93 0.09 / 117.25 6 6
2 7 2011.04 40 14.82 3040 1802 1.89 / 119.05 6 13
3 13 1303.44 20 14.94 2095 626 2.52 / 119.68 5 19
4 13 742.20 20 15.06 1317 397 2.92 / 120.07 5 23
5 13 154.88 20 15.22 485 148 3.07 / 120.22 5 16
6 13 83.84 20 15.23 377 115 3.18 / 120.33 5 15
7 8 0.04 276 15.21 249 1045 4.23 / 121.38 5 145
Average= 4.19
(KJ/cycle)

Cycle 27 GMT 18/10/2023 18:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 16 15.22 376 92 0.09 / 112.96 6 6
2 7 2008.16 40 14.83 3032 1799 1.89 / 114.76 6 13
3 13 1395.96 20 14.93 2211 660 2.55 / 115.42 5 19
4 13 820.08 20 15.04 1418 427 2.98 / 115.85 5 23
5 13 174.36 20 15.22 514 156 3.13 / 116.00 5 17
6 13 65.32 20 15.24 350 107 3.24 / 116.11 5 14
7 8 0.00 276 15.22 249 1046 4.29 / 117.15 5 141
Average= 4.18
(KJ/cycle)

Cycle 26 GMT 13/10/2023 17:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 16 15.22 381 93 0.09 / 108.69 6 6
2 7 2012.64 41 14.83 3031 1843 1.94 / 110.53 6 12
3 13 1357.28 20 14.94 2155 644 2.58 / 111.18 5 19
4 13 722.80 20 15.07 1291 389 2.97 / 111.57 5 23
5 13 184.72 20 15.22 524 160 3.13 / 111.73 5 16
6 13 80.40 20 15.24 369 112 3.24 / 111.84 5 13
7 8 0.08 276 15.22 245 1029 4.27 / 112.87 5 144
Average= 4.18
(KJ/cycle)

Cycle 25 GMT 8/10/2023 16:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 16 15.22 386 94 0.09 / 104.42 6 6
2 7 2002.52 40 14.83 3025 1794 1.89 / 106.21 6 13
3 13 1394.28 20 14.94 2206 659 2.55 / 106.87 5 19
4 13 767.76 20 15.06 1346 405 2.95 / 107.27 5 23
5 13 215.44 20 15.22 569 173 3.13 / 107.45 5 17
6 13 75.96 20 15.25 360 110 3.24 / 107.56 5 13
7 8 0.04 276 15.22 248 1042 4.28 / 108.60 5 132
Average= 4.18
(KJ/cycle)

Cycle 24 GMT 3/10/2023 16:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 16 15.21 417 101 0.10 / 100.12 6 6
2 7 2004.04 40 14.84 3031 1799 1.90 / 101.92 6 12
3 13 1425.44 20 14.93 2243 670 2.57 / 102.59 5 18
4 13 765.12 20 15.07 1354 408 2.98 / 103.00 5 23
5 13 200.80 20 15.22 548 167 3.15 / 103.16 5 18
6 13 86.00 20 15.24 380 116 3.26 / 103.28 5 15
7 8 0.28 276 15.23 248 1042 4.30 / 104.32 5 146
Average= 4.17
(KJ/cycle)

Cycle 23 GMT 28/ 9/2023 15:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 16 15.21 401 98 0.10 / 95.80 5 6
2 7 2003.40 40 14.84 3033 1800 1.90 / 97.60 6 13
3 13 1361.56 20 14.96 2165 648 2.55 / 98.25 5 19
4 13 850.68 20 15.04 1476 444 2.99 / 98.69 5 24
5 13 122.72 20 15.24 441 134 3.12 / 98.83 5 19
6 13 58.60 20 15.25 346 106 3.23 / 98.93 5 17
7 8 0.04 276 15.22 258 1084 4.31 / 100.02 5 152
Average= 4.17
(KJ/cycle)

Cycle 22 GMT 23/ 9/2023 15:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 16 15.22 392 95 0.10 / 91.54 5 6
2 7 2003.04 41 14.84 3027 1842 1.94 / 93.38 6 13
3 13 1340.76 20 14.96 2129 637 2.57 / 94.02 5 19
4 13 690.68 20 15.09 1249 377 2.95 / 94.39 5 24
5 13 91.24 20 15.25 399 122 3.07 / 94.52 5 21
6 13 31.16 20 15.25 315 96 3.17 / 94.61 5 20
7 8 0.04 274 15.22 262 1093 4.26 / 95.70 5 145
Average= 4.16
(KJ/cycle)

Cycle 21 GMT 18/ 9/2023 14:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 16 15.22 403 98 0.10 / 87.32 5 6
2 7 2012.00 40 14.85 3042 1807 1.91 / 89.12 6 13
3 13 1352.92 20 14.96 2154 644 2.55 / 89.77 5 19
4 13 698.56 20 15.09 1255 379 2.93 / 90.15 5 25
5 13 75.52 20 15.26 379 116 3.04 / 90.26 5 20
6 13 24.40 20 15.26 305 93 3.14 / 90.35 5 19
7 8 -0.08 274 15.22 261 1088 4.23 / 91.44 5 138
Average= 4.16
(KJ/cycle)

Cycle 20 GMT 13/ 9/2023 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 16 15.22 395 96 0.10 / 83.09 5 6
2 7 2002.16 41 14.85 3028 1844 1.94 / 84.93 6 13
3 13 1306.92 20 14.97 2101 629 2.57 / 85.56 5 19
4 13 660.20 20 15.10 1211 366 2.93 / 85.92 5 25
5 13 73.44 20 15.26 376 115 3.05 / 86.04 5 21
6 13 23.72 20 15.26 308 94 3.14 / 86.13 5 20
7 8 0.08 274 15.22 260 1084 4.23 / 87.22 5 136
Average= 4.15
(KJ/cycle)

Cycle 19 GMT 8/ 9/2023 12:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 16 15.23 402 98 0.10 / 78.83 5 6
2 7 2014.80 40 14.86 3050 1813 1.91 / 80.64 6 13
3 13 1353.96 20 14.96 2158 646 2.56 / 81.29 5 19
4 13 752.52 20 15.07 1337 403 2.96 / 81.69 5 24
5 13 85.04 20 15.26 395 121 3.08 / 81.81 5 19
6 13 28.88 20 15.26 310 95 3.17 / 81.90 5 19
7 8 -0.08 276 15.23 258 1084 4.26 / 82.99 5 143
Average= 4.15
(KJ/cycle)

Cycle 18 GMT 3/ 9/2023 12: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 16 15.23 395 96 0.10 / 74.61 6 6
2 7 2008.32 40 14.86 3039 1806 1.90 / 76.41 6 13
3 13 1346.00 20 14.96 2141 641 2.54 / 77.06 5 19
4 13 693.96 20 15.09 1246 376 2.92 / 77.43 5 24
5 13 101.68 20 15.25 417 127 3.05 / 77.56 5 19
6 13 42.24 20 15.26 325 99 3.15 / 77.66 5 17
7 8 0.08 274 15.23 257 1072 4.22 / 78.73 5 147
Average= 4.14
(KJ/cycle)

Cycle 17 GMT 29/ 8/2023 11:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 16 15.23 379 92 0.09 / 70.37 6 6
2 7 2009.88 40 14.86 3038 1806 1.90 / 72.18 6 13
3 13 1355.04 20 14.97 2158 646 2.54 / 72.82 5 19
4 13 675.24 20 15.10 1224 370 2.91 / 73.19 5 24
5 13 158.56 20 15.24 501 153 3.07 / 73.34 5 21
6 13 53.72 20 15.26 342 104 3.17 / 73.45 5 17
7 8 -0.20 274 15.23 255 1064 4.24 / 74.51 5 137
Average= 4.14
(KJ/cycle)

Cycle 16 GMT 24/ 8/2023 10:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 16 15.23 404 98 0.10 / 66.19 6 6
2 7 2003.80 40 14.86 3033 1803 1.90 / 67.99 6 13
3 13 1334.36 20 14.98 2127 637 2.54 / 68.63 5 19
4 13 629.84 20 15.12 1163 352 2.89 / 68.98 5 24
5 13 122.84 20 15.25 442 135 3.03 / 69.12 5 18
6 13 57.80 20 15.27 347 106 3.13 / 69.22 5 17
7 8 0.08 274 15.24 252 1052 4.18 / 70.28 5 130
Average= 4.13
(KJ/cycle)

Cycle 15 GMT 19/ 8/2023 9:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 16 15.23 386 94 0.09 / 61.94 6 6
2 7 2008.96 40 14.87 3041 1809 1.90 / 63.75 6 13
3 13 1340.80 20 14.98 2143 642 2.54 / 64.39 5 19
4 13 714.84 20 15.10 1284 388 2.93 / 64.78 5 23
5 13 158.16 20 15.25 489 149 3.08 / 64.93 5 18
6 13 52.64 20 15.27 334 102 3.18 / 65.03 5 15
7 8 -0.04 278 15.24 251 1063 4.25 / 66.09 5 150
Average= 4.13
(KJ/cycle)

Cycle 14 GMT 14/ 8/2023 8:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 16 15.24 404 99 0.10 / 57.64 6 6
2 7 2011.12 40 14.87 3037 1806 1.90 / 59.45 6 13
3 13 1393.28 20 14.98 2197 658 2.56 / 60.11 5 19
4 13 744.24 20 15.09 1323 399 2.96 / 60.51 5 24
5 13 168.08 20 15.25 510 156 3.12 / 60.66 5 19
6 13 59.60 20 15.27 348 106 3.22 / 60.77 5 16
7 8 0.08 278 15.24 254 1076 4.30 / 61.85 5 147
Average= 4.12
(KJ/cycle)

Cycle 13 GMT 9/ 8/2023 8:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 16 15.24 382 93 0.09 / 53.34 6 6
2 7 2011.08 40 14.88 3039 1809 1.90 / 55.15 6 13
3 13 1448.60 20 14.96 2271 679 2.58 / 55.83 5 18
4 13 709.16 20 15.10 1275 385 2.97 / 56.21 5 24
5 13 168.12 20 15.25 511 156 3.12 / 56.37 5 19
6 13 63.76 20 15.27 353 108 3.23 / 56.47 5 15
7 8 0.04 278 15.24 253 1072 4.30 / 57.55 5 149
Average= 4.11
(KJ/cycle)

Cycle 12 GMT 4/ 8/2023 7:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 16 15.24 384 94 0.09 / 49.05 6 6
2 7 2003.84 41 14.88 3015 1839 1.93 / 50.89 6 13
3 13 1336.28 20 14.99 2129 638 2.57 / 51.53 5 19
4 13 728.88 20 15.10 1299 392 2.96 / 51.92 5 23
5 13 172.44 20 15.25 508 155 3.12 / 52.07 5 17
6 13 66.16 20 15.27 350 107 3.23 / 52.18 5 14
7 8 0.04 278 15.25 251 1064 4.29 / 53.24 5 143
Average= 4.10
(KJ/cycle)

Cycle 11 GMT 30/ 7/2023 6:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 16 15.25 380 93 0.09 / 44.77 6 6
2 7 2003.36 40 14.89 3027 1803 1.90 / 46.57 6 12
3 13 1393.40 20 14.98 2199 659 2.55 / 47.23 5 18
4 13 743.16 20 15.10 1320 399 2.95 / 47.63 5 23
5 13 192.60 20 15.25 534 163 3.12 / 47.79 5 16
6 13 80.20 20 15.28 369 113 3.23 / 47.90 5 14
7 8 0.00 278 15.25 248 1051 4.28 / 48.95 5 135
Average= 4.08
(KJ/cycle)

Cycle 10 GMT 25/ 7/2023 6:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 16 15.24 385 94 0.09 / 40.47 6 6
2 7 2009.80 40 14.89 3027 1803 1.90 / 42.27 6 12
3 13 1408.32 20 14.98 2225 667 2.56 / 42.94 5 18
4 13 759.00 20 15.10 1336 403 2.97 / 43.34 5 23
5 13 207.20 20 15.25 553 169 3.14 / 43.51 5 16
6 13 96.04 20 15.27 390 119 3.25 / 43.63 5 14
7 8 0.12 278 15.25 247 1047 4.30 / 44.67 5 135
Average= 4.06
(KJ/cycle)

Cycle 9 GMT 20/ 7/2023 5:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 16 15.25 384 94 0.09 / 36.14 6 6
2 7 2007.80 41 14.89 3025 1847 1.94 / 37.98 6 12
3 13 1382.72 20 14.99 2185 655 2.60 / 38.64 5 18
4 13 772.60 20 15.10 1355 409 3.00 / 39.05 5 23
5 13 212.92 20 15.25 560 171 3.18 / 39.22 5 16
6 13 72.00 20 15.28 352 108 3.28 / 39.33 5 12
7 8 0.16 280 15.26 245 1047 4.33 / 40.37 5 166
Average= 4.04
(KJ/cycle)

Cycle 8 GMT 15/ 7/2023 5: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 15 15.25 377 86 0.09 / 31.82 6 6
2 3 1543.48 1 15.11 2433 37 0.12 / 31.86 5 10
3 7 2005.12 40 14.89 3023 1800 1.92 / 33.66 10 12
4 13 1389.72 20 14.99 2189 656 2.58 / 34.31 5 18
5 13 741.40 20 15.11 1303 394 2.97 / 34.71 5 23
6 13 233.52 20 15.25 591 180 3.15 / 34.89 5 17
7 13 84.28 20 15.28 372 114 3.27 / 35.00 5 13
8 8 0.12 280 15.26 244 1043 4.31 / 36.04 5 143
Average= 4.00
(KJ/cycle)

Cycle 7 GMT 10/ 7/2023 4:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 23 15.25 379 133 0.13 / 27.56 6 6
2 3 1244.84 -4 15.57 1 0 0.00 / 27.56 6 6
3 7 2012.64 40 14.90 3044 1814 1.95 / 29.37 6 12
4 13 1352.20 20 15.00 2157 647 2.59 / 30.02 5 18
5 13 718.44 20 15.12 1284 388 2.98 / 30.41 5 23
6 13 216.36 20 15.25 566 173 3.16 / 30.58 5 16
7 13 71.12 20 15.29 352 108 3.26 / 30.69 5 12
8 8 0.08 280 15.26 245 1047 4.31 / 31.73 5 140
Average= 3.97
(KJ/cycle)

Cycle 6 GMT 5/ 7/2023 3:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 17 15.25 395 102 0.10 / 22.91 6 6
2 10 1500.00 5 15.08 2314 174 0.28 / 23.08 5 6
3 10 1505.44 3 15.09 2339 106 0.38 / 23.19 5 7
4 7 2008.52 40 14.90 3031 1806 2.19 / 25.00 7 12
5 13 1405.76 20 14.99 2220 666 2.85 / 25.66 5 18
6 13 789.36 20 15.10 1378 416 3.27 / 26.08 5 22
7 13 232.36 20 15.25 589 180 3.45 / 26.26 5 16
8 13 86.96 20 15.29 375 115 3.57 / 26.37 5 12
9 8 0.08 280 15.26 246 1051 4.62 / 27.42 5 144
Average= 3.92
(KJ/cycle)

Cycle 5 GMT 30/ 6/2023 2:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 16 15.25 379 92 0.09 / 18.59 6 6
2 3 1548.28 1 15.12 2445 37 0.13 / 18.63 5 10
3 7 2005.08 40 14.90 3019 1799 1.93 / 20.43 10 12
4 13 1310.28 20 15.01 2091 628 2.56 / 21.05 5 19
5 13 757.68 20 15.11 1335 403 2.96 / 21.46 5 22
6 13 244.52 20 15.25 605 185 3.14 / 21.64 5 16
7 13 98.48 20 15.28 388 119 3.26 / 21.76 5 12
8 8 0.08 282 15.26 243 1046 4.31 / 22.81 5 136
Average= 3.80
(KJ/cycle)

Cycle 4 GMT 25/ 6/2023 2: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 16 15.25 375 91 0.09 / 14.33 6 6
2 7 2009.88 40 14.91 3018 1800 1.89 / 16.13 6 12
3 13 1379.28 20 15.00 2184 655 2.55 / 16.79 5 18
4 13 730.44 20 15.12 1295 392 2.94 / 17.18 5 22
5 13 221.12 20 15.26 568 173 3.11 / 17.35 5 15
6 13 76.28 20 15.29 356 109 3.22 / 17.46 5 12
7 8 0.12 280 15.26 243 1038 4.26 / 18.50 5 157
Average= 3.70
(KJ/cycle)

Cycle 3 GMT 20/ 6/2023 1:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 16 15.25 371 91 0.09 / 10.07 6 6
2 7 2011.88 40 14.91 3035 1810 1.90 / 11.88 6 12
3 13 1383.28 20 15.00 2193 658 2.56 / 12.54 5 18
4 13 736.96 20 15.13 1304 395 2.95 / 12.93 5 22
5 13 226.28 20 15.26 573 175 3.13 / 13.11 5 15
6 13 47.84 20 15.30 313 96 3.22 / 13.21 5 11
7 8 0.16 280 15.26 242 1034 4.26 / 14.24 5 152
Average= 3.56
(KJ/cycle)

Cycle 2 GMT 15/ 6/2023 0:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 14 15.21 373 79 0.08 / 5.75 6 6
2 10 1501.08 3 15.09 2354 107 0.19 / 5.86 5 7
3 7 2011.36 40 14.91 3025 1804 1.99 / 7.66 7 12
4 13 1351.24 20 15.01 2132 640 2.63 / 8.30 5 19
5 13 707.24 20 15.13 1258 381 3.01 / 8.68 5 22
6 13 196.28 20 15.26 534 163 3.17 / 8.84 5 15
7 13 83.44 20 15.28 366 112 3.29 / 8.95 5 13
8 8 0.00 278 15.26 242 1027 4.31 / 9.98 5 139
Average= 3.33
(KJ/cycle)

Cycle 1 GMT 9/ 6/2023 23:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 18 15.45 354 98 0.10 / 1.62 6 6
2 3 1361.44 -2 15.60 1 0 0.00 / 1.62 6 6
3 7 2008.88 40 14.90 3039 1811 1.91 / 3.43 6 12
4 13 1299.28 20 14.99 2079 623 2.53 / 4.05 5 19
5 13 675.84 20 15.11 1214 367 2.90 / 4.42 5 21
6 13 174.52 20 15.23 498 152 3.05 / 4.57 5 15
7 13 35.96 20 15.26 291 89 3.14 / 4.66 5 12
8 8 0.08 278 15.23 239 1012 4.15 / 5.67 5 132
Average= 2.83
(KJ/cycle)

Cycle 0 GMT 4/ 6/2023 23:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 18 15.60 366 103 0.10 / 0.10 6 6
2 7 122.36 40 15.58 387 241 0.34 / 0.34 6 6
3 13 147.96 20 15.56 419 130 0.47 / 0.47 6 6
4 13 121.56 20 15.55 375 117 0.59 / 0.59 6 7
5 8 0.08 287 15.51 208 926 1.52 / 1.52 6 -99
Average= 1.52
(KJ/cycle)