SIO Argo Site:
Pump Diagnostics Page   



Serial= 7704 WMO= 4903477

Return

←PreviousNext→

Cycle 56 GMT 4/ 5/2024 8:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 34 15.04 473 242 0.24 / 324.11 5 6
2 7 2012.04 40 14.73 3378 1990 2.23 / 326.10 6 27
3 13 1812.92 20 14.70 3118 917 3.15 / 327.01 5 30
4 13 1367.76 20 14.71 2486 731 3.88 / 327.74 5 36
5 13 694.12 20 14.87 1470 437 4.32 / 328.18 5 44
6 13 67.36 20 15.07 495 149 4.47 / 328.33 5 37
7 13 18.16 20 15.07 403 121 4.59 / 328.45 5 28
8 8 -0.04 272 15.02 353 1442 6.03 / 329.89 5 137
Average= 5.79
(KJ/cycle)

Cycle 55 GMT 24/ 4/2024 1:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 34 15.05 465 238 0.24 / 318.02 5 6
2 7 2013.60 40 14.72 3394 1998 2.24 / 320.02 6 28
3 13 1914.80 20 14.68 3269 960 3.20 / 320.98 5 30
4 13 1261.36 20 14.74 2342 690 3.89 / 321.67 5 38
5 13 710.92 20 14.86 1516 451 4.34 / 322.12 5 43
6 13 43.64 20 15.08 457 138 4.47 / 322.25 5 33
7 13 16.08 20 15.08 411 124 4.60 / 322.38 5 30
8 8 0.00 274 15.02 361 1486 6.08 / 323.86 5 140
Average= 5.78
(KJ/cycle)

Cycle 54 GMT 13/ 4/2024 18: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 34 15.05 475 243 0.24 / 311.86 5 6
2 7 2007.76 40 14.73 3381 1992 2.24 / 313.85 6 27
3 13 1910.60 20 14.70 3254 957 3.19 / 314.81 5 30
4 13 1457.00 20 14.71 2623 772 3.96 / 315.58 5 37
5 13 773.00 20 14.85 1596 474 4.44 / 316.06 5 43
6 13 58.88 20 15.08 481 145 4.58 / 316.20 5 35
7 13 35.80 20 15.08 432 130 4.71 / 316.33 5 34
8 8 0.00 270 15.03 357 1449 6.16 / 317.78 5 156
Average= 5.78
(KJ/cycle)

Cycle 53 GMT 3/ 4/2024 10:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 34 15.06 477 244 0.24 / 305.85 5 6
2 7 2004.76 40 14.73 3380 1991 2.24 / 307.84 6 26
3 13 1907.36 20 14.70 3253 956 3.19 / 308.79 5 30
4 13 1242.40 20 14.77 2294 678 3.87 / 309.47 5 37
5 13 708.84 20 14.88 1499 446 4.32 / 309.92 5 43
6 13 46.80 20 15.09 446 135 4.45 / 310.05 5 34
7 13 30.08 20 15.09 417 126 4.58 / 310.18 5 35
8 8 0.04 276 15.04 347 1440 6.02 / 311.62 5 172
Average= 5.77
(KJ/cycle)

Cycle 52 GMT 24/ 3/2024 3:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 34 15.06 482 247 0.25 / 299.84 5 6
2 7 2006.32 40 14.73 3391 1998 2.24 / 301.84 6 28
3 13 1908.76 20 14.69 3274 962 3.21 / 302.80 5 30
4 13 1340.96 20 14.74 2450 722 3.93 / 303.52 5 37
5 13 580.96 20 14.93 1301 388 4.32 / 303.91 5 44
6 13 68.96 20 15.09 486 147 4.46 / 304.06 5 36
7 13 19.80 20 15.10 407 123 4.59 / 304.18 5 31
8 8 0.00 270 15.05 350 1422 6.01 / 305.60 5 157
Average= 5.77
(KJ/cycle)

Cycle 51 GMT 13/ 3/2024 20: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 34 15.07 474 243 0.24 / 293.78 5 6
2 7 2011.32 41 14.73 3389 2047 2.29 / 295.83 20 27
3 13 1917.24 20 14.70 3283 965 3.25 / 296.79 5 31
4 13 1061.24 20 14.82 2040 605 3.86 / 297.40 5 40
5 13 640.52 20 14.91 1397 417 4.28 / 297.82 5 44
6 13 48.32 20 15.10 474 143 4.42 / 297.96 5 34
7 13 14.96 20 15.10 417 126 4.55 / 298.08 5 30
8 8 -0.12 274 15.04 366 1508 6.05 / 299.59 5 156
Average= 5.76
(KJ/cycle)

Cycle 50 GMT 3/ 3/2024 12:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 34 15.08 468 240 0.24 / 287.76 5 6
2 7 2005.32 40 14.73 3390 1997 2.24 / 289.76 6 27
3 13 1909.80 20 14.70 3268 961 3.20 / 290.72 5 30
4 13 1256.88 20 14.77 2330 688 3.89 / 291.41 5 38
5 13 621.64 20 14.93 1366 408 4.29 / 291.82 5 44
6 13 77.92 20 15.10 514 155 4.45 / 291.97 5 40
7 13 43.76 20 15.10 443 134 4.58 / 292.11 5 35
8 8 -0.08 272 15.05 350 1433 6.02 / 293.54 5 174
Average= 5.76
(KJ/cycle)

Cycle 49 GMT 22/ 2/2024 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 34 15.08 479 246 0.25 / 281.91 5 6
2 7 2009.24 40 14.75 3374 1991 2.24 / 283.90 6 27
3 13 1700.96 20 14.74 2962 873 3.11 / 284.78 5 32
4 13 1182.48 20 14.80 2203 652 3.76 / 285.43 5 38
5 13 659.00 20 14.92 1416 423 4.18 / 285.85 5 44
6 13 58.36 20 15.11 465 141 4.32 / 285.99 5 36
7 13 18.48 20 15.12 395 119 4.44 / 286.11 5 31
8 8 -0.04 272 15.06 345 1413 5.86 / 287.52 5 167
Average= 5.75
(KJ/cycle)

Cycle 48 GMT 11/ 2/2024 21:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 34 15.08 489 251 0.25 / 275.80 5 6
2 7 2003.76 40 14.74 3381 1993 2.24 / 277.80 6 27
3 13 1915.16 20 14.71 3268 961 3.21 / 278.76 5 30
4 13 1366.36 20 14.76 2481 732 3.94 / 279.49 5 36
5 13 696.84 20 14.92 1484 443 4.38 / 279.93 5 44
6 13 68.72 20 15.11 494 149 4.53 / 280.08 5 37
7 13 22.24 20 15.12 415 125 4.66 / 280.21 5 32
8 8 -0.08 276 15.06 351 1459 6.11 / 281.67 5 141
Average= 5.75
(KJ/cycle)

Cycle 47 GMT 1/ 2/2024 14:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 34 15.09 475 244 0.24 / 269.96 5 6
2 7 2009.64 40 14.74 3393 2001 2.24 / 271.96 6 28
3 13 1706.52 20 14.74 2986 880 3.12 / 272.84 5 33
4 13 1288.24 20 14.78 2375 702 3.83 / 273.54 5 37
5 13 446.24 20 15.00 1094 328 4.15 / 273.87 5 44
6 13 64.96 20 15.12 479 145 4.30 / 274.02 5 37
7 8 0.04 289 15.08 352 1534 5.83 / 275.55 5 142
Average= 5.74
(KJ/cycle)

Cycle 46 GMT 22/ 1/2024 6:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 34 15.10 478 245 0.25 / 264.01 5 6
2 7 2004.04 40 14.75 3386 1998 2.24 / 266.01 6 27
3 13 1805.72 20 14.73 3131 922 3.17 / 266.93 5 32
4 13 1168.08 20 14.82 2188 649 3.81 / 267.58 5 37
5 13 627.96 20 14.95 1383 414 4.23 / 267.99 5 44
6 13 44.52 20 15.13 455 138 4.37 / 268.13 5 33
7 13 25.56 20 15.13 414 125 4.49 / 268.26 5 32
8 8 -0.04 274 15.07 354 1462 5.95 / 269.72 5 151
Average= 5.74
(KJ/cycle)

Cycle 45 GMT 11/ 1/2024 23:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 34 15.10 464 238 0.24 / 258.07 5 6
2 7 2004.80 40 14.76 3366 1987 2.23 / 260.06 6 27
3 13 1908.04 20 14.72 3251 957 3.18 / 261.01 5 30
4 13 1249.40 20 14.81 2306 683 3.87 / 261.70 5 38
5 13 615.44 20 14.96 1364 408 4.27 / 262.10 5 44
6 13 53.52 20 15.14 452 137 4.41 / 262.24 5 35
7 8 0.08 291 15.09 347 1524 5.93 / 263.77 5 145
Average= 5.73
(KJ/cycle)

Cycle 44 GMT 1/ 1/2024 15:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 34 15.10 479 246 0.25 / 252.09 5 6
2 7 2005.36 40 14.76 3370 1990 2.24 / 254.08 6 28
3 13 1708.44 20 14.76 2984 881 3.12 / 254.96 5 33
4 13 1290.92 20 14.80 2372 702 3.82 / 255.67 5 39
5 13 641.92 20 14.95 1408 421 4.24 / 256.09 5 44
6 13 49.36 20 15.14 456 138 4.38 / 256.22 5 36
7 13 30.04 20 15.14 418 127 4.50 / 256.35 5 33
8 8 -0.08 278 15.08 353 1480 5.98 / 257.83 5 147
Average= 5.73
(KJ/cycle)

Cycle 43 GMT 22/12/2023 8:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 34 15.11 463 238 0.24 / 246.02 5 6
2 7 2010.04 40 14.77 3373 1993 2.23 / 248.01 6 28
3 13 1925.76 20 14.72 3282 966 3.20 / 248.98 5 30
4 13 1181.44 20 14.84 2213 657 3.85 / 249.64 5 39
5 13 749.12 20 14.93 1559 466 4.32 / 250.10 5 44
6 13 50.68 20 15.14 461 140 4.46 / 250.24 5 35
7 13 34.80 20 15.14 428 130 4.59 / 250.37 5 34
8 8 -0.08 278 15.09 352 1477 6.07 / 251.85 5 182
Average= 5.72
(KJ/cycle)

Cycle 42 GMT 12/12/2023 0:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 34 15.12 464 239 0.24 / 239.98 5 6
2 7 2005.76 40 14.77 3376 1995 2.23 / 241.97 6 28
3 13 1908.56 20 14.74 3253 959 3.19 / 242.93 5 31
4 13 1138.92 20 14.86 2155 640 3.83 / 243.57 5 39
5 13 722.24 20 14.95 1528 457 4.29 / 244.03 5 43
6 13 79.04 20 15.14 522 158 4.45 / 244.19 5 39
7 13 43.92 20 15.14 455 138 4.59 / 244.33 5 37
8 8 0.00 270 15.10 357 1455 6.04 / 245.78 5 144
Average= 5.72
(KJ/cycle)

Cycle 41 GMT 1/12/2023 17:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 34 15.12 483 248 0.25 / 233.97 5 6
2 7 2002.72 40 14.77 3383 1999 2.25 / 235.97 6 27
3 13 1795.40 20 14.76 3111 918 3.17 / 236.89 5 32
4 13 1253.56 20 14.83 2329 691 3.86 / 237.58 5 38
5 13 708.08 20 14.95 1516 453 4.31 / 238.04 5 43
6 13 71.96 20 15.15 516 156 4.47 / 238.19 5 39
7 13 42.56 20 15.15 458 139 4.60 / 238.33 5 35
8 8 0.00 263 15.11 355 1411 6.02 / 239.74 5 147
Average= 5.71
(KJ/cycle)

Cycle 40 GMT 21/11/2023 10: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 34 15.13 474 244 0.24 / 227.91 5 6
2 7 2006.04 40 14.77 3381 1997 2.24 / 229.90 6 28
3 13 1907.24 20 14.75 3266 963 3.20 / 230.87 5 30
4 13 1221.04 20 14.85 2271 674 3.88 / 231.54 5 37
5 13 684.40 20 14.97 1466 439 4.32 / 231.98 5 43
6 13 67.44 20 15.15 498 151 4.47 / 232.13 5 39
7 13 39.20 20 15.16 443 134 4.60 / 232.27 5 35
8 8 -0.16 270 15.11 358 1461 6.06 / 233.73 5 172
Average= 5.70
(KJ/cycle)

Cycle 39 GMT 11/11/2023 2:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 34 15.13 468 241 0.24 / 221.88 5 6
2 7 2012.44 40 14.77 3388 2002 2.24 / 223.88 6 27
3 13 1913.44 20 14.75 3266 963 3.21 / 224.84 5 31
4 13 1238.68 20 14.86 2287 680 3.89 / 225.52 5 37
5 13 695.32 20 14.97 1491 446 4.33 / 225.97 5 44
6 13 78.20 20 15.15 525 159 4.49 / 226.13 5 39
7 13 21.48 20 15.17 410 124 4.62 / 226.25 5 31
8 8 0.08 263 15.12 354 1408 6.02 / 227.66 5 148
Average= 5.69
(KJ/cycle)

Cycle 38 GMT 31/10/2023 19:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 34 15.13 476 245 0.24 / 215.84 5 6
2 7 2004.88 40 14.78 3380 1998 2.24 / 217.84 6 28
3 13 1804.84 20 14.77 3108 918 3.16 / 218.76 5 32
4 13 1469.68 20 14.79 2626 777 3.94 / 219.54 5 36
5 13 597.96 20 15.00 1335 400 4.34 / 219.94 5 44
6 13 82.56 20 15.16 520 158 4.50 / 220.10 5 39
7 13 47.76 20 15.16 458 139 4.64 / 220.23 5 37
8 8 -0.08 263 15.12 353 1404 6.04 / 221.64 5 203
Average= 5.68
(KJ/cycle)

Cycle 37 GMT 21/10/2023 12: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 34 15.14 469 241 0.24 / 209.72 5 6
2 7 2006.24 40 14.78 3391 2005 2.25 / 211.73 6 27
3 13 1819.08 20 14.77 3127 924 3.17 / 212.65 5 31
4 13 1284.68 20 14.84 2366 702 3.87 / 213.35 5 37
5 13 844.68 20 14.93 1710 511 4.38 / 213.87 5 43
6 13 91.08 20 15.16 537 163 4.55 / 214.03 5 38
7 13 49.36 20 15.16 472 143 4.69 / 214.17 5 37
8 8 -0.04 261 15.12 362 1429 6.12 / 215.60 5 188
Average= 5.67
(KJ/cycle)

Cycle 36 GMT 11/10/2023 4:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 34 15.15 453 233 0.23 / 203.61 5 6
2 7 2006.40 40 14.78 3381 1999 2.23 / 205.61 6 27
3 13 1914.84 20 14.77 3246 959 3.19 / 206.57 5 30
4 13 1372.24 20 14.83 2498 741 3.93 / 207.31 5 36
5 13 705.52 20 14.98 1507 451 4.38 / 207.76 5 44
6 13 81.96 20 15.17 522 158 4.54 / 207.92 5 38
7 13 44.96 20 15.17 459 139 4.68 / 208.06 5 35
8 8 -0.16 263 15.13 357 1421 6.10 / 209.48 5 179
Average= 5.66
(KJ/cycle)

Cycle 35 GMT 30/ 9/2023 21:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 34 15.16 469 242 0.24 / 197.70 5 6
2 7 2006.32 40 14.78 3390 2004 2.25 / 199.71 6 27
3 13 1810.60 20 14.78 3111 920 3.17 / 200.63 5 31
4 13 1260.28 20 14.86 2328 692 3.86 / 201.32 5 37
5 13 593.72 20 15.01 1338 402 4.26 / 201.72 5 44
6 13 76.60 20 15.17 501 152 4.41 / 201.87 5 39
7 13 43.00 20 15.18 444 135 4.55 / 202.01 5 36
8 8 0.00 261 15.13 348 1374 5.92 / 203.38 5 139
Average= 5.65
(KJ/cycle)

Cycle 34 GMT 20/ 9/2023 13:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 34 15.16 472 243 0.24 / 191.74 5 6
2 7 2004.00 40 14.79 3393 2007 2.25 / 193.74 6 28
3 13 1906.12 20 14.76 3275 967 3.22 / 194.71 5 30
4 13 1167.32 20 14.89 2196 654 3.87 / 195.37 5 38
5 13 735.64 20 14.97 1557 466 4.34 / 195.83 5 43
6 13 94.92 20 15.17 546 166 4.50 / 196.00 5 37
7 13 28.68 20 15.19 412 125 4.63 / 196.12 5 34
8 8 0.04 257 15.14 344 1338 5.97 / 197.46 5 136
Average= 5.64
(KJ/cycle)

Cycle 33 GMT 10/ 9/2023 6:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 33 15.15 481 240 0.24 / 185.82 5 6
2 7 2003.12 41 14.79 3390 2056 2.30 / 187.87 6 27
3 13 1683.36 20 14.81 2953 875 3.17 / 188.75 5 34
4 13 1166.72 20 14.89 2198 655 3.83 / 189.40 5 38
5 13 822.68 20 14.95 1682 503 4.33 / 189.91 5 42
6 13 91.64 20 15.18 516 157 4.48 / 190.06 5 36
7 13 50.28 20 15.19 448 136 4.62 / 190.20 5 33
8 8 0.04 250 15.15 342 1295 5.92 / 191.49 5 162
Average= 5.63
(KJ/cycle)

Cycle 32 GMT 30/ 8/2023 23: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 34 15.15 473 244 0.24 / 179.78 5 6
2 7 2003.32 41 14.79 3391 2056 2.30 / 181.84 6 28
3 13 1809.76 20 14.80 3121 924 3.22 / 182.76 5 31
4 13 1177.44 20 14.90 2207 658 3.88 / 183.42 5 39
5 13 639.28 20 15.01 1401 421 4.30 / 183.84 5 44
6 13 82.36 20 15.18 533 162 4.46 / 184.00 5 40
7 13 44.68 20 15.18 463 141 4.60 / 184.15 5 37
8 8 0.00 263 15.13 360 1433 6.04 / 185.58 5 162
Average= 5.62
(KJ/cycle)

Cycle 31 GMT 20/ 8/2023 15:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 34 15.16 486 251 0.25 / 173.88 5 7
2 7 2002.56 40 14.80 3392 2008 2.26 / 175.88 7 28
3 13 1704.12 20 14.82 2969 880 3.14 / 176.76 5 33
4 13 1180.08 20 14.89 2205 657 3.80 / 177.42 5 38
5 13 645.60 20 15.01 1409 423 4.22 / 177.84 5 45
6 13 91.92 20 15.18 533 162 4.38 / 178.01 5 40
7 13 49.32 20 15.19 460 140 4.52 / 178.14 5 37
8 8 -0.20 259 15.14 356 1396 5.92 / 179.54 5 161
Average= 5.61
(KJ/cycle)

Cycle 30 GMT 10/ 8/2023 8:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 34 15.17 458 236 0.24 / 167.98 5 6
2 7 2008.12 40 14.80 3399 2012 2.25 / 170.00 6 27
3 13 1606.64 20 14.84 2832 841 3.09 / 170.84 5 33
4 13 1182.24 20 14.89 2213 659 3.75 / 171.50 5 38
5 13 542.44 20 15.05 1251 377 4.12 / 171.87 5 44
6 13 94.00 20 15.18 556 169 4.29 / 172.04 5 40
7 13 50.84 20 15.18 480 146 4.44 / 172.19 5 38
8 8 -0.04 261 15.14 364 1438 5.88 / 173.63 5 153
Average= 5.60
(KJ/cycle)

Cycle 29 GMT 31/ 7/2023 0:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 34 15.17 471 243 0.24 / 161.94 5 6
2 7 2010.52 40 14.80 3405 2016 2.26 / 163.96 6 28
3 13 1812.60 20 14.81 3132 928 3.19 / 164.89 5 31
4 13 1264.24 20 14.88 2358 702 3.89 / 165.59 5 39
5 13 821.16 20 14.97 1674 501 4.39 / 166.09 5 43
6 13 72.48 20 15.19 498 151 4.54 / 166.24 5 38
7 13 43.24 20 15.20 441 134 4.67 / 166.38 5 37
8 8 0.08 257 15.16 352 1371 6.05 / 167.75 5 162
Average= 5.59
(KJ/cycle)

Cycle 28 GMT 20/ 7/2023 17:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 34 15.17 475 245 0.24 / 156.08 5 6
2 7 2004.88 40 14.80 3395 2010 2.25 / 158.09 6 28
3 13 1810.12 20 14.80 3136 928 3.18 / 159.02 5 31
4 13 1168.24 20 14.91 2202 657 3.84 / 159.67 5 39
5 13 539.24 20 15.06 1248 376 4.22 / 160.05 5 44
6 13 61.60 20 15.20 494 150 4.37 / 160.20 5 37
7 13 15.72 20 15.21 405 123 4.49 / 160.32 5 33
8 8 -0.04 255 15.15 357 1379 5.87 / 161.70 5 144
Average= 5.58
(KJ/cycle)

Cycle 27 GMT 10/ 7/2023 10: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 34 15.18 480 248 0.25 / 150.06 5 6
2 7 2005.16 40 14.81 3395 2011 2.26 / 152.07 6 27
3 13 1907.16 20 14.79 3266 966 3.23 / 153.04 5 30
4 13 1240.52 20 14.90 2302 686 3.91 / 153.73 5 38
5 13 598.20 20 15.04 1340 403 4.31 / 154.13 5 45
6 13 79.56 20 15.20 518 157 4.47 / 154.29 5 39
7 13 44.96 20 15.20 459 140 4.61 / 154.43 5 35
8 8 0.00 257 15.16 361 1406 6.02 / 155.83 5 136
Average= 5.57
(KJ/cycle)

Cycle 26 GMT 30/ 6/2023 2:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 34 15.17 471 243 0.24 / 144.07 5 6
2 7 2005.00 40 14.82 3395 2013 2.26 / 146.08 6 28
3 13 1808.68 20 14.82 3134 929 3.18 / 147.01 5 31
4 13 1270.32 20 14.89 2339 697 3.88 / 147.71 5 38
5 13 534.32 20 15.07 1238 373 4.25 / 148.08 5 44
6 13 67.16 20 15.21 509 155 4.41 / 148.24 5 37
7 13 18.48 20 15.21 428 130 4.54 / 148.37 5 30
8 8 0.00 259 15.16 369 1449 5.99 / 149.82 5 178
Average= 5.55
(KJ/cycle)

Cycle 25 GMT 19/ 6/2023 19:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 34 15.18 476 246 0.25 / 137.94 5 6
2 7 2003.56 40 14.82 3401 2016 2.26 / 139.96 6 28
3 13 1809.44 20 14.82 3134 929 3.19 / 140.89 5 31
4 13 1365.76 20 14.88 2502 745 3.94 / 141.63 5 37
5 13 602.04 20 15.05 1358 409 4.34 / 142.04 5 44
6 13 78.68 20 15.20 521 158 4.50 / 142.20 5 39
7 13 42.60 20 15.21 457 139 4.64 / 142.34 5 37
8 8 -0.08 267 15.16 368 1490 6.13 / 143.83 5 143
Average= 5.53
(KJ/cycle)

Cycle 24 GMT 9/ 6/2023 11:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 34 15.17 505 260 0.26 / 131.82 5 6
2 7 2009.40 40 14.82 3401 2016 2.28 / 133.84 6 26
3 13 1714.96 20 14.84 3011 894 3.17 / 134.73 5 32
4 13 1401.72 20 14.86 2552 758 3.93 / 135.49 5 37
5 13 610.20 20 15.04 1372 413 4.34 / 135.90 5 45
6 13 78.44 20 15.20 532 162 4.50 / 136.06 5 39
7 13 22.92 20 15.21 431 131 4.63 / 136.19 5 32
8 8 0.00 263 15.16 377 1503 6.14 / 137.70 5 140
Average= 5.51
(KJ/cycle)

Cycle 23 GMT 30/ 5/2023 4:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 34 15.19 485 250 0.25 / 125.66 5 6
2 7 2004.68 40 14.83 3386 2009 2.26 / 127.67 6 27
3 13 1907.28 20 14.82 3258 966 3.22 / 128.63 5 30
4 13 1174.48 20 14.93 2212 661 3.89 / 129.29 5 38
5 13 657.92 20 15.04 1436 432 4.32 / 129.72 5 44
6 13 49.60 20 15.22 484 147 4.46 / 129.87 5 36
7 13 29.96 20 15.21 450 137 4.60 / 130.01 5 34
8 8 -0.12 270 15.16 379 1551 6.15 / 131.56 5 141
Average= 5.48
(KJ/cycle)

Cycle 22 GMT 19/ 5/2023 20:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 33 15.18 485 243 0.24 / 119.62 5 6
2 7 2006.04 40 14.83 3404 2019 2.26 / 121.64 6 27
3 13 1808.56 20 14.83 3129 928 3.19 / 122.56 5 31
4 13 1176.84 20 14.93 2213 661 3.85 / 123.22 5 39
5 13 642.48 20 15.04 1415 426 4.28 / 123.65 5 44
6 13 52.92 20 15.22 475 145 4.42 / 123.79 5 36
7 13 16.24 20 15.23 414 126 4.55 / 123.92 5 31
8 8 0.00 267 15.17 367 1486 6.03 / 125.41 5 160
Average= 5.45
(KJ/cycle)

Cycle 21 GMT 9/ 5/2023 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 33 15.19 483 242 0.24 / 113.57 5 6
2 7 2008.40 40 14.84 3373 2002 2.24 / 115.57 10 27
3 13 1799.84 20 14.85 3098 920 3.16 / 116.49 5 32
4 13 1270.44 20 14.92 2343 699 3.86 / 117.19 5 37
5 13 622.28 20 15.06 1371 413 4.28 / 117.60 5 44
6 13 46.16 20 15.23 464 141 4.42 / 117.74 5 35
7 13 31.04 20 15.22 439 134 4.55 / 117.88 5 34
8 8 -0.12 267 15.17 369 1495 6.05 / 119.37 5 148
Average= 5.43
(KJ/cycle)

Cycle 20 GMT 29/ 4/2023 5:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 33 15.20 471 236 0.24 / 107.54 5 6
2 7 2003.48 41 14.84 3391 2063 2.30 / 109.61 6 27
3 13 1807.64 20 14.84 3140 932 3.23 / 110.54 5 31
4 13 1155.48 20 14.95 2170 649 3.88 / 111.19 5 38
5 13 611.68 20 15.06 1352 407 4.29 / 111.59 5 44
6 13 35.68 20 15.23 445 136 4.42 / 111.73 5 34
7 13 13.92 20 15.23 406 124 4.55 / 111.85 5 32
8 8 0.00 267 15.17 364 1474 6.02 / 113.33 5 137
Average= 5.40
(KJ/cycle)

Cycle 19 GMT 18/ 4/2023 22:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 33 15.20 473 237 0.24 / 101.53 5 6
2 7 2006.52 40 14.84 3400 2018 2.26 / 103.55 6 27
3 13 1910.60 20 14.83 3270 970 3.23 / 104.52 5 30
4 13 1148.48 20 14.95 2166 648 3.87 / 105.16 5 38
5 13 728.20 20 15.03 1534 461 4.33 / 105.63 5 43
6 13 42.92 20 15.24 445 136 4.47 / 105.76 5 36
7 13 16.80 20 15.24 403 123 4.59 / 105.88 5 33
8 8 -0.04 263 15.19 356 1422 6.01 / 107.31 5 183
Average= 5.37
(KJ/cycle)

Cycle 18 GMT 8/ 4/2023 15: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 33 15.21 476 239 0.24 / 95.48 5 6
2 7 2005.00 41 14.84 3392 2064 2.30 / 97.55 6 29
3 13 1909.92 20 14.84 3283 974 3.28 / 98.52 5 31
4 13 1143.56 20 14.95 2170 649 3.93 / 99.17 5 38
5 13 719.72 20 15.04 1521 458 4.38 / 99.63 5 43
6 13 46.52 20 15.24 459 140 4.52 / 99.77 5 36
7 8 0.32 282 15.19 356 1525 6.05 / 101.29 5 141
Average= 5.33
(KJ/cycle)

Cycle 17 GMT 29/ 3/2023 7:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 33 15.21 476 239 0.24 / 89.57 5 6
2 7 2003.48 40 14.86 3385 2012 2.25 / 91.59 13 27
3 13 1805.96 20 14.87 3105 923 3.17 / 92.51 5 31
4 13 1167.44 20 14.96 2193 656 3.83 / 93.17 5 38
5 13 638.72 20 15.07 1399 422 4.25 / 93.59 5 44
6 13 52.80 20 15.24 462 141 4.39 / 93.73 5 36
7 13 29.56 20 15.24 422 129 4.52 / 93.86 5 33
8 8 -0.04 257 15.19 355 1386 5.91 / 95.24 5 132
Average= 5.29
(KJ/cycle)

Cycle 16 GMT 19/ 3/2023 0: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 33 15.21 485 243 0.24 / 83.63 5 6
2 7 2011.44 40 14.86 3407 2025 2.27 / 85.65 6 26
3 13 1812.52 20 14.86 3131 931 3.20 / 86.58 5 32
4 13 1175.64 20 14.96 2211 662 3.86 / 87.24 5 38
5 13 638.84 20 15.07 1407 424 4.28 / 87.67 5 44
6 13 57.00 20 15.24 477 145 4.43 / 87.81 5 37
7 13 16.04 20 15.25 401 122 4.55 / 87.93 5 32
8 8 0.08 259 15.19 356 1401 5.95 / 89.34 5 162
Average= 5.26
(KJ/cycle)

Cycle 15 GMT 8/ 3/2023 16:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 33 15.21 484 243 0.24 / 77.62 5 6
2 7 2003.60 40 14.87 3385 2013 2.26 / 79.63 6 28
3 13 1905.92 20 14.85 3245 964 3.22 / 80.59 5 30
4 13 1231.52 20 14.95 2276 681 3.90 / 81.27 5 38
5 13 579.32 20 15.10 1299 392 4.29 / 81.67 5 44
6 13 62.20 20 15.24 498 152 4.44 / 81.82 5 37
7 13 17.32 20 15.25 410 125 4.57 / 81.94 5 32
8 8 -0.08 261 15.19 363 1439 6.01 / 83.38 5 162
Average= 5.21
(KJ/cycle)

Cycle 14 GMT 26/ 2/2023 9: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 33 15.22 457 230 0.23 / 71.63 5 6
2 7 2008.68 40 14.87 3400 2022 2.25 / 73.65 8 26
3 13 1708.32 20 14.89 2986 889 3.14 / 74.54 5 31
4 13 1296.52 20 14.93 2376 709 3.85 / 75.25 5 38
5 13 623.80 20 15.08 1377 415 4.27 / 75.66 5 44
6 13 73.92 20 15.24 509 155 4.42 / 75.82 5 39
7 13 19.44 20 15.25 410 125 4.55 / 75.94 5 34
8 8 -0.04 261 15.20 360 1428 5.97 / 77.37 5 146
Average= 5.16
(KJ/cycle)

Cycle 13 GMT 16/ 2/2023 1:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 33 15.22 457 230 0.23 / 65.78 5 6
2 7 2004.48 41 14.87 3386 2064 2.29 / 67.84 6 27
3 13 1706.96 20 14.90 2973 886 3.18 / 68.73 5 33
4 13 1087.64 20 14.98 2079 623 3.80 / 69.35 5 40
5 13 653.68 20 15.07 1411 425 4.23 / 69.77 5 44
6 13 55.80 20 15.25 471 144 4.37 / 69.92 5 37
7 13 30.84 20 15.25 422 129 4.50 / 70.05 5 35
8 8 0.00 255 15.20 349 1353 5.85 / 71.40 5 143
Average= 5.10
(KJ/cycle)

Cycle 12 GMT 5/ 2/2023 18:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 33 15.22 452 227 0.23 / 60.00 5 6
2 7 2009.92 40 14.87 3384 2013 2.24 / 62.01 6 28
3 13 1714.16 20 14.89 3002 894 3.13 / 62.90 5 32
4 13 1182.12 20 14.97 2225 666 3.80 / 63.57 5 37
5 13 528.52 20 15.11 1235 373 4.17 / 63.94 5 45
6 13 59.52 20 15.25 471 144 4.32 / 64.09 5 36
7 8 -0.08 274 15.21 350 1459 5.78 / 65.55 5 177
Average= 5.04
(KJ/cycle)

Cycle 11 GMT 26/ 1/2023 10:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 33 15.23 457 230 0.23 / 54.18 5 6
2 7 2011.32 40 14.88 3395 2021 2.25 / 56.20 6 26
3 13 1812.64 20 14.89 3114 927 3.18 / 57.13 5 32
4 13 1085.88 20 15.00 2057 617 3.79 / 57.74 5 39
5 13 669.60 20 15.08 1432 432 4.23 / 58.18 5 44
6 13 99.00 20 15.24 536 163 4.39 / 58.34 5 40
7 8 0.08 274 15.22 343 1430 5.82 / 59.77 5 133
Average= 4.98
(KJ/cycle)

Cycle 10 GMT 16/ 1/2023 3:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 33 15.23 449 226 0.23 / 48.45 5 6
2 7 2006.92 40 14.88 3390 2018 2.24 / 50.47 6 27
3 13 1711.60 20 14.91 2977 888 3.13 / 51.36 5 32
4 13 1109.04 20 14.99 2120 636 3.77 / 51.99 5 39
5 13 590.16 20 15.10 1326 400 4.17 / 52.40 5 44
6 13 71.48 20 15.25 490 149 4.32 / 52.54 5 39
7 8 0.08 274 15.22 337 1405 5.72 / 53.95 5 141
Average= 4.90
(KJ/cycle)

Cycle 9 GMT 5/ 1/2023 19:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 33 15.24 447 225 0.22 / 42.72 5 6
2 7 2005.84 40 14.90 3377 2013 2.24 / 44.73 6 27
3 13 1813.48 20 14.89 3138 934 3.17 / 45.67 5 32
4 13 1069.44 20 15.00 2060 618 3.79 / 46.28 5 39
5 13 640.44 20 15.09 1382 417 4.21 / 46.70 5 44
6 13 87.84 20 15.25 516 157 4.36 / 46.86 5 39
7 8 -0.04 270 15.23 333 1369 5.73 / 48.23 5 182
Average= 4.82
(KJ/cycle)

Cycle 8 GMT 26/12/2022 11:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 32 15.23 452 220 0.22 / 36.96 5 6
2 7 2010.92 40 14.89 3376 2011 2.23 / 38.97 9 27
3 13 1813.40 20 14.90 3103 925 3.16 / 39.90 5 30
4 13 1255.76 20 14.96 2311 691 3.85 / 40.59 5 37
5 13 595.12 20 15.11 1320 399 4.25 / 40.99 5 45
6 13 79.44 20 15.26 494 151 4.40 / 41.14 5 39
7 8 0.00 274 15.23 325 1356 5.75 / 42.49 5 153
Average= 4.72
(KJ/cycle)

Cycle 7 GMT 16/12/2022 4:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 32 15.23 444 216 0.22 / 31.11 5 6
2 7 2009.80 40 14.91 3353 2000 2.22 / 33.11 13 28
3 13 1913.00 20 14.89 3258 970 3.19 / 34.08 5 29
4 13 1147.76 20 15.00 2154 646 3.83 / 34.73 5 38
5 13 614.44 20 15.11 1341 405 4.24 / 35.13 5 44
6 13 78.40 20 15.26 504 154 4.39 / 35.29 5 38
7 13 19.80 20 15.27 401 122 4.51 / 35.41 5 31
8 8 -0.08 253 15.22 346 1332 5.85 / 36.74 5 145
Average= 4.59
(KJ/cycle)

Cycle 6 GMT 5/12/2022 21: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 31 15.24 438 207 0.21 / 25.18 5 6
2 3 1042.24 1 15.24 1986 30 0.24 / 25.21 5 31
3 7 2011.68 40 14.90 3376 2012 2.25 / 27.22 31 27
4 13 1916.04 20 14.89 3247 967 3.22 / 28.19 5 30
5 13 1264.48 20 14.97 2326 696 3.91 / 28.89 5 37
6 13 731.60 20 15.08 1518 458 4.37 / 29.35 5 43
7 13 76.96 20 15.26 498 152 4.52 / 29.50 5 38
8 8 -0.08 278 15.23 330 1397 5.92 / 30.89 5 179
Average= 4.41
(KJ/cycle)

Cycle 5 GMT 25/11/2022 13:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 31 15.25 458 217 0.22 / 19.56 5 6
2 7 2008.20 40 14.92 3351 2000 2.22 / 21.56 6 25
3 13 1804.04 20 14.92 3084 920 3.14 / 22.48 5 31
4 13 1066.92 20 15.02 2032 610 3.75 / 23.09 5 37
5 13 635.40 20 15.11 1370 414 4.16 / 23.51 5 43
6 13 85.36 20 15.26 485 148 4.31 / 23.66 5 39
7 8 0.08 272 15.24 318 1318 5.63 / 24.97 5 138
Average= 4.16
(KJ/cycle)

Cycle 4 GMT 15/11/2022 6: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 30 15.25 428 196 0.20 / 14.59 5 6
2 7 1509.92 40 15.07 2647 1596 1.79 / 16.19 6 28
3 13 1430.80 20 15.05 2532 762 2.55 / 16.95 5 32
4 13 1112.04 20 15.06 2091 630 3.18 / 17.58 5 37
5 13 440.20 20 15.19 1066 324 3.51 / 17.90 5 43
6 13 54.52 20 15.29 432 132 3.64 / 18.04 5 35
7 8 0.04 263 15.25 327 1312 4.95 / 19.35 5 133
Average= 3.87
(KJ/cycle)

Cycle 3 GMT 13/11/2022 19:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 30 15.24 438 200 0.20 / 9.72 5 6
2 7 1513.08 41 15.06 2651 1637 1.84 / 11.36 22 28
3 13 1432.96 20 15.05 2534 763 2.60 / 12.12 5 31
4 13 1005.44 20 15.08 1924 580 3.18 / 12.70 5 38
5 13 347.88 20 15.21 906 276 3.46 / 12.98 5 42
6 13 64.00 20 15.29 451 138 3.59 / 13.12 5 37
7 8 0.00 263 15.25 319 1279 4.87 / 14.40 5 138
Average= 3.60
(KJ/cycle)

Cycle 2 GMT 12/11/2022 9:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 31 15.27 435 206 0.21 / 4.93 5 6
2 3 955.32 -1 15.57 0 0 0.00 / 4.93 5 6
3 7 1518.36 40 15.06 2657 1601 1.81 / 6.53 6 28
4 13 1426.32 20 15.05 2524 760 2.57 / 7.29 5 30
5 13 997.64 20 15.08 1903 574 3.14 / 7.86 5 38
6 13 342.96 20 15.21 898 273 3.41 / 8.14 5 43
7 13 64.92 20 15.28 441 135 3.55 / 8.27 5 35
8 8 0.00 261 15.25 315 1254 4.80 / 9.52 5 143
Average= 3.17
(KJ/cycle)

Cycle 1 GMT 10/11/2022 23:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 31 15.44 409 196 0.20 / 1.84 5 6
2 3 948.88 -1 15.58 0 0 0.00 / 1.84 5 6
3 7 1011.48 40 15.16 1914 1161 1.36 / 3.00 6 36
4 13 477.92 20 15.25 1106 337 1.69 / 3.34 5 41
5 13 68.00 20 15.33 445 136 1.83 / 3.47 5 35
6 8 -0.12 261 15.29 313 1249 3.08 / 4.72 5 137
Average= 2.36
(KJ/cycle)

Cycle 0 GMT 10/11/2022 12:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 30 15.59 428 200 0.20 / 0.20 5 8
2 7 118.44 40 15.57 438 273 0.47 / 0.47 8 8
3 13 88.68 20 15.56 393 122 0.60 / 0.60 5 10
4 13 48.36 20 15.55 326 101 0.70 / 0.70 5 9
5 8 0.32 242 15.51 252 946 1.64 / 1.64 5 181
Average= 1.64
(KJ/cycle)