SIO Argo Site:
Pump Diagnostics Page   



Serial= 7726 WMO= 4903468

Return

←PreviousNext→

Cycle 117 GMT 2/ 5/2024 10:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 17 15.02 473 121 0.12 / 635.86 5 6
2 7 2006.68 40 14.68 3090 1814 1.94 / 637.68 6 22
3 13 1973.96 20 14.64 3053 894 2.83 / 638.57 5 23
4 13 1186.36 20 14.73 2054 605 3.43 / 639.18 5 31
5 13 864.12 20 14.78 1630 482 3.92 / 639.66 5 36
6 13 64.16 20 15.03 456 137 4.05 / 639.80 5 33
7 8 -0.04 319 14.98 345 1649 5.70 / 641.45 5 147
Average= 5.44
(KJ/cycle)

Cycle 116 GMT 27/ 4/2024 9:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 17 15.02 475 121 0.12 / 630.09 5 6
2 7 2006.32 40 14.67 3093 1815 1.94 / 631.90 6 23
3 13 1939.60 20 14.65 3016 884 2.82 / 632.79 5 25
4 13 1413.88 20 14.68 2349 690 3.51 / 633.48 5 29
5 13 812.44 20 14.80 1564 463 3.97 / 633.94 5 36
6 13 84.80 20 15.03 488 147 4.12 / 634.09 5 32
7 8 0.08 321 14.98 345 1659 5.78 / 635.74 5 160
Average= 5.43
(KJ/cycle)

Cycle 115 GMT 22/ 4/2024 7:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 17 15.01 480 122 0.12 / 624.33 5 6
2 7 2009.72 40 14.68 3091 1815 1.94 / 626.15 6 23
3 13 1978.04 20 14.64 3067 898 2.84 / 627.05 5 24
4 13 1404.20 20 14.68 2337 686 3.52 / 627.73 5 30
5 13 805.40 20 14.80 1545 457 3.98 / 628.19 5 36
6 13 119.28 20 15.02 541 163 4.14 / 628.35 5 31
7 8 0.00 314 14.99 343 1614 5.76 / 629.97 5 132
Average= 5.43
(KJ/cycle)

Cycle 114 GMT 17/ 4/2024 6:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 17 15.02 471 120 0.12 / 618.63 5 6
2 7 2004.16 41 14.67 3086 1856 1.98 / 620.49 6 22
3 13 1938.16 20 14.64 3022 885 2.86 / 621.38 5 22
4 13 1346.16 20 14.70 2249 661 3.52 / 622.04 5 31
5 13 644.48 20 14.85 1321 392 3.91 / 622.43 5 37
6 13 78.28 20 15.03 472 142 4.06 / 622.57 5 30
7 8 -0.08 319 14.98 343 1639 5.70 / 624.21 5 144
Average= 5.43
(KJ/cycle)

Cycle 113 GMT 12/ 4/2024 4:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 17 15.01 469 120 0.12 / 612.91 5 6
2 7 2008.08 41 14.67 3078 1851 1.97 / 614.76 6 23
3 13 1941.16 20 14.65 3001 879 2.85 / 615.64 5 22
4 13 1387.36 20 14.68 2328 684 3.53 / 616.32 5 31
5 13 680.64 20 14.84 1377 409 3.94 / 616.73 5 38
6 13 72.76 20 15.03 465 140 4.08 / 616.87 5 28
7 8 0.08 319 14.98 344 1644 5.73 / 618.51 5 143
Average= 5.43
(KJ/cycle)

Cycle 112 GMT 7/ 4/2024 3:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 17 15.01 477 122 0.12 / 607.11 5 6
2 7 2007.84 40 14.67 3090 1813 1.93 / 608.92 6 21
3 13 1941.56 20 14.65 3022 885 2.82 / 609.81 5 24
4 13 1473.96 20 14.67 2423 711 3.53 / 610.52 5 30
5 13 788.20 20 14.80 1523 451 3.98 / 610.97 5 36
6 13 92.96 20 15.03 502 151 4.13 / 611.12 5 33
7 8 0.04 321 14.98 347 1669 5.80 / 612.79 5 140
Average= 5.42
(KJ/cycle)

Cycle 111 GMT 2/ 4/2024 1:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 17 15.03 469 120 0.12 / 601.40 5 6
2 7 2007.92 41 14.67 3095 1862 1.98 / 603.26 6 21
3 13 1875.80 20 14.66 2940 862 2.84 / 604.13 5 26
4 13 1246.12 20 14.72 2137 629 3.47 / 604.76 5 31
5 13 700.28 20 14.83 1408 418 3.89 / 605.17 5 36
6 13 78.84 20 15.03 481 145 4.03 / 605.32 5 32
7 8 0.04 321 14.98 347 1669 5.70 / 606.99 5 148
Average= 5.42
(KJ/cycle)

Cycle 110 GMT 28/ 3/2024 0: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 17 15.03 473 121 0.12 / 595.84 5 6
2 7 2003.52 40 14.68 3077 1807 1.93 / 597.65 6 22
3 13 1936.56 20 14.65 2990 876 2.80 / 598.52 5 23
4 13 1382.92 20 14.69 2311 679 3.48 / 599.20 5 31
5 13 609.36 20 14.87 1263 376 3.86 / 599.58 5 37
6 13 59.64 20 15.05 442 133 3.99 / 599.71 5 27
7 8 0.08 310 15.00 338 1572 5.56 / 601.28 5 149
Average= 5.42
(KJ/cycle)

Cycle 109 GMT 22/ 3/2024 22:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 17 15.03 484 124 0.12 / 590.23 6 6
2 7 2009.96 41 14.67 3097 1863 1.99 / 592.09 6 22
3 13 1910.12 20 14.64 2973 870 2.86 / 592.96 5 24
4 13 1227.92 20 14.72 2105 620 3.48 / 593.58 5 32
5 13 782.76 20 14.81 1519 450 3.93 / 594.03 5 37
6 13 96.84 20 15.04 495 149 4.08 / 594.18 5 27
7 8 0.08 308 15.00 334 1543 5.62 / 595.72 5 169
Average= 5.42
(KJ/cycle)

Cycle 108 GMT 17/ 3/2024 20:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 17 15.03 461 118 0.12 / 584.60 6 6
2 7 2010.52 40 14.68 3100 1820 1.94 / 586.42 6 23
3 13 1944.36 20 14.64 3010 881 2.82 / 587.30 5 23
4 13 1286.08 20 14.71 2184 643 3.46 / 587.94 5 30
5 13 805.76 20 14.81 1545 458 3.92 / 588.40 5 35
6 13 88.40 20 15.04 490 147 4.07 / 588.55 5 27
7 8 0.04 304 15.00 341 1555 5.62 / 590.10 5 136
Average= 5.41
(KJ/cycle)

Cycle 107 GMT 12/ 3/2024 19:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 17 15.04 463 118 0.12 / 578.96 6 6
2 7 2008.64 41 14.66 3099 1863 1.98 / 580.82 6 23
3 13 1943.52 20 14.64 3012 882 2.86 / 581.70 5 25
4 13 1354.44 20 14.69 2270 667 3.53 / 582.37 5 29
5 13 701.92 20 14.84 1391 413 3.94 / 582.78 5 36
6 13 132.08 20 15.03 555 167 4.11 / 582.95 5 28
7 8 0.12 300 15.01 340 1531 5.64 / 584.48 5 139
Average= 5.41
(KJ/cycle)

Cycle 106 GMT 7/ 3/2024 17:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 17 15.04 477 122 0.12 / 573.38 6 6
2 7 2008.68 40 14.67 3103 1821 1.94 / 575.20 6 22
3 13 1875.04 20 14.66 2937 861 2.80 / 576.07 5 26
4 13 1324.32 20 14.70 2230 656 3.46 / 576.72 5 31
5 13 805.60 20 14.81 1544 457 3.92 / 577.18 5 37
6 13 177.04 20 15.01 621 186 4.10 / 577.36 5 29
7 8 0.00 295 15.01 333 1475 5.58 / 578.84 5 132
Average= 5.41
(KJ/cycle)

Cycle 105 GMT 2/ 3/2024 16:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 17 15.06 467 120 0.12 / 567.74 6 6
2 7 2002.56 40 14.68 3081 1809 1.93 / 569.55 6 21
3 13 1936.12 20 14.65 2995 878 2.81 / 570.43 5 23
4 13 1354.36 20 14.70 2267 666 3.47 / 571.09 5 29
5 13 755.96 20 14.83 1481 439 3.91 / 571.53 5 35
6 13 156.64 20 15.03 583 175 4.09 / 571.71 5 28
7 13 86.64 20 15.04 480 144 4.23 / 571.85 5 27
8 8 0.08 278 15.01 338 1410 5.64 / 573.26 5 134
Average= 5.41
(KJ/cycle)

Cycle 104 GMT 26/ 2/2024 14:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 17 15.03 475 121 0.12 / 562.26 5 6
2 7 2004.00 40 14.68 3085 1812 1.93 / 564.08 6 21
3 13 1937.44 20 14.66 3005 881 2.81 / 564.96 5 25
4 13 1325.48 20 14.71 2245 660 3.47 / 565.62 5 32
5 13 664.96 20 14.86 1343 399 3.87 / 566.02 5 37
6 13 111.28 20 15.05 510 154 4.03 / 566.17 5 27
7 8 0.04 297 15.02 325 1450 5.48 / 567.62 5 137
Average= 5.41
(KJ/cycle)

Cycle 103 GMT 21/ 2/2024 13:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 17 15.02 481 123 0.12 / 556.52 5 7
2 7 2007.20 40 14.69 3084 1812 1.93 / 558.33 7 21
3 13 1975.88 20 14.66 3059 897 2.83 / 559.23 5 25
4 13 1506.84 20 14.68 2452 720 3.55 / 559.95 5 29
5 13 683.56 20 14.86 1373 408 3.96 / 560.36 5 37
6 13 158.00 20 15.02 593 178 4.14 / 560.53 5 31
7 8 0.16 310 15.00 346 1609 5.75 / 562.14 5 147
Average= 5.41
(KJ/cycle)

Cycle 102 GMT 16/ 2/2024 11:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 17 15.02 480 123 0.12 / 550.83 5 7
2 7 2003.80 40 14.68 3083 1810 1.93 / 552.64 7 22
3 13 1870.68 20 14.67 2929 859 2.79 / 553.50 5 26
4 13 1438.84 20 14.69 2402 706 3.50 / 554.21 5 30
5 13 649.48 20 14.87 1325 394 3.89 / 554.60 5 37
6 13 48.48 20 15.06 430 130 4.02 / 554.73 5 27
7 8 0.12 319 15.00 348 1665 5.69 / 556.40 5 143
Average= 5.40
(KJ/cycle)

Cycle 101 GMT 11/ 2/2024 9:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 17 15.03 482 123 0.12 / 545.08 5 6
2 7 2002.80 40 14.69 3086 1813 1.94 / 546.89 6 24
3 13 1937.60 20 14.66 3013 883 2.82 / 547.77 5 23
4 13 1322.36 20 14.72 2226 655 3.48 / 548.43 5 30
5 13 796.72 20 14.81 1536 455 3.93 / 548.88 5 36
6 13 73.20 20 15.04 472 142 4.07 / 549.02 5 30
7 8 0.00 321 14.99 350 1684 5.76 / 550.71 5 130
Average= 5.40
(KJ/cycle)

Cycle 100 GMT 6/ 2/2024 8:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 17 15.04 474 121 0.12 / 539.36 5 6
2 7 2004.72 41 14.68 3085 1857 1.98 / 541.22 6 22
3 13 1939.00 20 14.66 3004 881 2.86 / 542.10 5 24
4 13 1305.52 20 14.72 2214 652 3.51 / 542.75 5 30
5 13 649.48 20 14.87 1323 393 3.90 / 543.15 5 37
6 13 112.76 20 15.04 536 161 4.07 / 543.31 5 32
7 8 0.08 319 15.00 344 1646 5.71 / 544.95 5 139
Average= 5.40
(KJ/cycle)

Cycle 99 GMT 1/ 2/2024 6:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 17 15.03 476 122 0.12 / 533.70 5 6
2 7 2011.20 40 14.69 3081 1810 1.93 / 535.51 6 23
3 13 1979.80 20 14.65 3059 896 2.83 / 536.41 5 23
4 13 1394.64 20 14.70 2332 686 3.51 / 537.09 5 29
5 13 663.64 20 14.87 1345 400 3.91 / 537.49 5 37
6 13 138.68 20 15.04 572 172 4.09 / 537.66 5 31
7 8 0.04 312 15.01 337 1578 5.66 / 539.24 5 140
Average= 5.39
(KJ/cycle)

Cycle 98 GMT 27/ 1/2024 5:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 18 15.03 496 134 0.13 / 528.05 5 6
2 7 2006.48 41 14.69 3081 1856 1.99 / 529.91 6 22
3 13 1868.44 20 14.67 2921 857 2.85 / 530.76 5 24
4 13 1133.32 20 14.76 1988 587 3.43 / 531.35 5 32
5 13 810.68 20 14.82 1540 456 3.89 / 531.81 5 37
6 13 101.08 20 15.04 508 153 4.04 / 531.96 5 32
7 8 -0.04 317 15.00 340 1617 5.66 / 533.58 5 146
Average= 5.39
(KJ/cycle)

Cycle 97 GMT 22/ 1/2024 3:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 1504.60 7 14.85 2451 255 0.25 / 521.91 5 14
2 10 1517.08 6 14.84 2471 220 0.47 / 522.13 5 16
3 10 1526.36 4 14.85 2478 147 0.62 / 522.28 5 17
4 10 1533.04 3 14.83 2531 113 0.73 / 522.39 5 18
5 3 1550.12 1 14.91 2545 38 0.77 / 522.43 5 23
6 7 2002.56 40 14.69 3097 1820 2.59 / 524.25 23 21
7 13 1936.64 20 14.66 3019 885 3.48 / 525.14 5 25
8 13 1178.36 20 14.75 2047 604 4.08 / 525.74 5 32
9 13 634.20 20 14.88 1305 388 4.47 / 526.13 5 38
10 13 85.36 20 15.05 488 147 4.62 / 526.28 5 30
11 8 0.00 317 15.00 345 1640 6.26 / 527.92 5 134
Average= 5.39
(KJ/cycle)

Cycle 96 GMT 17/ 1/2024 2: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 44 15.02 478 316 0.32 / 517.25 5 8
2 3 465.36 -1 15.34 0 0 0.00 / 517.25 5 8
3 7 1215.32 40 14.98 2063 1236 1.55 / 518.49 8 23
4 13 1193.76 20 14.96 2044 612 2.16 / 519.10 5 26
5 13 981.16 20 14.93 1776 530 2.69 / 519.63 5 30
6 13 497.60 20 15.00 1106 332 3.03 / 519.96 5 35
7 13 24.64 20 15.12 389 118 3.14 / 520.08 5 24
8 8 0.00 308 15.05 341 1581 4.72 / 521.66 5 152
Average= 5.38
(KJ/cycle)

Cycle 95 GMT 15/ 1/2024 4:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 44 15.03 479 317 0.32 / 512.58 5 7
2 7 1220.08 40 14.99 2078 1246 1.56 / 513.82 7 23
3 13 1204.56 20 14.95 2067 618 2.18 / 514.44 5 26
4 13 940.16 20 14.93 1713 512 2.69 / 514.95 5 30
5 13 346.88 20 15.04 875 263 2.96 / 515.22 5 35
6 8 0.08 332 15.05 344 1719 4.67 / 516.94 5 133
Average= 5.38
(KJ/cycle)

Cycle 94 GMT 13/ 1/2024 7:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 43 15.01 477 308 0.31 / 507.74 5 8
2 7 1218.04 40 14.98 2071 1241 1.55 / 508.98 8 24
3 13 1197.76 20 14.95 2047 612 2.16 / 509.59 5 25
4 13 1063.76 20 14.92 1878 560 2.72 / 510.16 5 30
5 13 503.48 20 15.00 1108 332 3.05 / 510.49 5 36
6 13 27.08 20 15.12 401 121 3.17 / 510.61 5 27
7 8 0.00 312 15.05 352 1653 4.83 / 512.26 5 146
Average= 5.39
(KJ/cycle)

Cycle 93 GMT 11/ 1/2024 10:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 43 15.04 463 299 0.30 / 502.98 5 7
2 7 1213.76 40 14.97 2068 1238 1.54 / 504.21 7 23
3 13 1193.32 20 14.95 2039 610 2.15 / 504.82 5 25
4 13 1092.96 20 14.91 1915 571 2.72 / 505.39 5 29
5 13 395.32 20 15.02 947 284 3.00 / 505.68 5 35
6 13 40.52 20 15.11 422 128 3.13 / 505.81 5 30
7 8 0.08 310 15.04 349 1627 4.76 / 507.43 5 131
Average= 5.40
(KJ/cycle)

Cycle 92 GMT 9/ 1/2024 13: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 35 15.03 470 247 0.25 / 498.52 5 7
2 10 502.80 3 15.12 1071 49 0.30 / 498.57 5 12
3 10 509.00 3 15.12 1077 49 0.34 / 498.62 5 14
4 3 583.12 2 15.13 1201 36 0.38 / 498.65 5 20
5 7 973.12 40 15.04 1743 1049 1.43 / 499.70 20 27
6 13 958.56 20 15.02 1727 519 1.95 / 500.22 5 30
7 13 928.36 20 14.98 1691 507 2.46 / 500.73 5 31
8 13 439.08 20 15.04 1010 304 2.76 / 501.03 5 37
9 8 0.00 325 15.07 336 1646 4.40 / 502.68 5 145
Average= 5.41
(KJ/cycle)

Cycle 91 GMT 7/ 1/2024 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 10 15.06 487 73 0.07 / 494.61 5 6
2 3 714.52 -4 15.39 0 0 0.00 / 494.61 5 6
3 7 715.08 40 15.11 1402 847 0.92 / 495.46 6 29
4 13 714.76 20 15.09 1407 425 1.35 / 495.88 5 31
5 13 689.40 20 15.05 1373 413 1.76 / 496.29 5 30
6 13 392.20 20 15.08 939 283 2.04 / 496.58 5 35
7 8 0.04 323 15.07 348 1694 3.74 / 498.27 5 146
Average= 5.42
(KJ/cycle)

Cycle 90 GMT 2/ 1/2024 16:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 21 15.05 478 151 0.15 / 490.95 5 6
2 3 743.24 -4 15.40 0 0 0.00 / 490.95 5 6
3 7 742.76 40 15.11 1438 869 1.02 / 491.82 6 28
4 13 736.24 20 15.08 1433 432 1.45 / 492.25 5 31
5 13 709.52 20 15.05 1388 418 1.87 / 492.67 5 31
6 13 177.56 20 15.12 635 192 2.06 / 492.86 5 32
7 8 0.12 317 15.08 350 1673 3.74 / 494.54 5 153
Average= 5.43
(KJ/cycle)

Cycle 89 GMT 28/12/2023 17:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 26 15.04 482 188 0.19 / 487.07 5 6
2 3 839.80 -2 15.40 0 0 0.00 / 487.07 5 6
3 7 845.88 40 15.06 1579 951 1.14 / 488.02 6 30
4 13 835.52 20 15.04 1566 471 1.61 / 488.49 5 31
5 13 808.20 20 15.00 1545 463 2.07 / 488.95 5 34
6 13 264.88 20 15.09 752 227 2.30 / 489.18 5 35
7 8 0.08 317 15.07 339 1619 3.92 / 490.80 5 146
Average= 5.45
(KJ/cycle)

Cycle 88 GMT 23/12/2023 18:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 30 15.04 481 217 0.22 / 483.04 5 6
2 3 903.84 -1 15.41 0 0 0.00 / 483.04 5 6
3 7 899.64 40 15.05 1656 997 1.21 / 484.03 6 29
4 13 888.56 20 15.02 1644 494 1.71 / 484.53 5 31
5 13 860.16 20 14.99 1606 481 2.19 / 485.01 5 33
6 13 250.28 20 15.09 736 222 2.41 / 485.23 5 34
7 13 30.08 20 15.13 399 121 2.53 / 485.35 5 24
8 8 0.16 297 15.06 342 1530 4.06 / 486.88 5 143
Average= 5.47
(KJ/cycle)

Cycle 87 GMT 18/12/2023 19: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 27 15.04 471 191 0.19 / 478.67 5 6
2 10 1015.00 3 15.04 1817 82 0.27 / 478.75 5 19
3 3 1025.68 1 15.10 1862 28 0.30 / 478.78 5 23
4 7 1012.20 40 15.01 1803 1083 1.38 / 479.86 23 28
5 13 995.96 20 14.99 1792 537 1.92 / 480.40 5 30
6 13 966.04 20 14.95 1751 524 2.44 / 480.92 5 33
7 13 258.12 20 15.08 747 225 2.67 / 481.15 5 32
8 13 69.04 20 15.12 462 140 2.81 / 481.29 5 28
9 8 0.00 295 15.06 344 1528 4.34 / 482.82 5 142
Average= 5.49
(KJ/cycle)

Cycle 86 GMT 13/12/2023 19:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 7 15.05 481 51 0.05 / 474.09 5 6
2 3 1181.12 -5 15.40 0 0 0.00 / 474.09 5 6
3 7 1180.88 40 14.94 2038 1218 1.27 / 475.31 6 29
4 13 1161.32 20 14.92 2014 601 1.87 / 475.91 5 32
5 13 1096.52 20 14.88 1932 575 2.44 / 476.49 5 33
6 13 388.84 20 15.02 941 283 2.73 / 476.77 5 36
7 13 72.24 20 15.10 468 141 2.87 / 476.91 5 30
8 8 0.04 304 15.05 343 1569 4.44 / 478.48 5 148
Average= 5.50
(KJ/cycle)

Cycle 85 GMT 8/12/2023 19:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 17 15.05 471 121 0.12 / 469.48 5 6
2 3 1255.56 -4 15.41 0 0 0.00 / 469.48 5 6
3 7 1253.28 40 14.93 2122 1267 1.39 / 470.75 6 30
4 13 1230.44 20 14.90 2100 626 2.01 / 471.37 5 32
5 13 1130.12 20 14.87 1977 588 2.60 / 471.96 5 32
6 13 573.24 20 14.96 1213 363 2.96 / 472.32 5 37
7 13 59.28 20 15.10 443 134 3.10 / 472.46 5 29
8 8 0.00 304 15.04 347 1587 4.68 / 474.04 5 130
Average= 5.51
(KJ/cycle)

Cycle 84 GMT 3/12/2023 19:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 17 15.03 486 124 0.12 / 464.55 5 6
2 7 1485.56 41 14.85 2419 1473 1.60 / 466.03 6 25
3 13 1458.40 20 14.83 2374 704 2.30 / 466.73 5 29
4 13 1082.76 20 14.84 1915 568 2.87 / 467.30 5 33
5 13 572.48 20 14.93 1215 363 3.23 / 467.66 5 37
6 13 60.68 20 15.08 446 135 3.37 / 467.80 5 29
7 8 0.00 304 15.03 342 1563 4.93 / 469.36 5 139
Average= 5.52
(KJ/cycle)

Cycle 83 GMT 28/11/2023 18:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 17 15.06 454 116 0.12 / 459.16 6 6
2 7 1641.36 40 14.81 2622 1553 1.67 / 460.72 6 25
3 13 1622.88 20 14.77 2600 768 2.44 / 461.48 5 27
4 13 1593.20 20 14.72 2568 756 3.19 / 462.24 5 27
5 13 707.12 20 14.87 1419 422 3.62 / 462.66 5 37
6 13 91.24 20 15.06 503 152 3.77 / 462.81 5 31
7 8 0.16 308 15.02 349 1615 5.38 / 464.43 5 141
Average= 5.53
(KJ/cycle)

Cycle 82 GMT 23/11/2023 17:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 17 15.05 454 116 0.12 / 453.49 6 6
2 7 2014.08 40 14.70 3076 1809 1.92 / 455.30 6 22
3 13 1986.44 20 14.66 3068 900 2.82 / 456.20 5 23
4 13 1520.24 20 14.68 2482 729 3.55 / 456.93 5 29
5 13 798.56 20 14.82 1536 455 4.01 / 457.39 5 36
6 13 128.20 20 15.05 546 164 4.17 / 457.55 5 26
7 13 59.68 20 15.06 442 133 4.31 / 457.68 5 25
8 8 0.08 276 15.02 329 1364 5.67 / 459.05 5 140
Average= 5.53
(KJ/cycle)

Cycle 81 GMT 18/11/2023 15:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 17 15.05 471 121 0.12 / 447.97 6 6
2 7 2007.36 40 14.70 3068 1804 1.92 / 449.78 6 22
3 13 1874.92 20 14.68 2912 855 2.78 / 450.63 5 24
4 13 1255.12 20 14.74 2138 630 3.41 / 451.26 5 32
5 13 732.64 20 14.85 1449 430 3.84 / 451.69 5 36
6 13 158.68 20 15.03 598 180 4.02 / 451.87 5 30
7 13 49.08 20 15.06 426 128 4.15 / 452.00 5 25
8 8 -0.08 276 15.02 332 1376 5.52 / 453.38 5 145
Average= 5.53
(KJ/cycle)

Cycle 80 GMT 13/11/2023 14:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 17 15.04 480 123 0.12 / 442.42 6 6
2 7 2008.64 40 14.71 3073 1808 1.93 / 444.23 6 22
3 13 1801.72 20 14.69 2837 834 2.76 / 445.06 5 25
4 13 1296.12 20 14.74 2189 645 3.41 / 445.71 5 31
5 13 714.20 20 14.86 1420 422 3.83 / 446.13 5 37
6 13 120.12 20 15.05 542 163 3.99 / 446.29 5 30
7 8 0.08 306 15.02 339 1558 5.55 / 447.85 5 147
Average= 5.53
(KJ/cycle)

Cycle 79 GMT 8/11/2023 12:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 17 15.04 481 123 0.12 / 436.69 5 6
2 7 2010.44 40 14.71 3082 1813 1.94 / 438.50 6 22
3 13 1977.68 20 14.68 3057 898 2.83 / 439.40 5 23
4 13 1339.20 20 14.73 2256 665 3.50 / 440.07 5 31
5 13 810.96 20 14.83 1557 462 3.96 / 440.53 5 37
6 13 90.36 20 15.06 501 151 4.11 / 440.68 5 30
7 8 0.04 312 15.01 346 1620 5.73 / 442.30 5 150
Average= 5.53
(KJ/cycle)

Cycle 78 GMT 3/11/2023 10:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 17 15.04 480 123 0.12 / 431.02 5 6
2 7 2009.96 40 14.71 3078 1811 1.93 / 432.83 6 22
3 13 1944.08 20 14.68 3013 885 2.82 / 433.72 5 22
4 13 1390.28 20 14.72 2317 682 3.50 / 434.40 5 29
5 13 720.12 20 14.86 1427 424 3.92 / 434.83 5 37
6 13 81.48 20 15.06 483 145 4.07 / 434.97 5 29
7 13 30.72 20 15.07 406 122 4.19 / 435.09 5 26
8 8 0.12 287 15.02 342 1474 5.67 / 436.57 5 158
Average= 5.53
(KJ/cycle)

Cycle 77 GMT 29/10/2023 9:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 17 15.03 480 123 0.12 / 425.43 5 6
2 7 2008.64 40 14.71 3090 1818 1.94 / 427.25 6 23
3 13 1806.44 20 14.69 2841 835 2.78 / 428.08 5 25
4 13 1285.36 20 14.74 2185 644 3.42 / 428.73 5 32
5 13 661.84 20 14.88 1345 400 3.82 / 429.13 5 38
6 13 89.32 20 15.06 493 148 3.97 / 429.28 5 30
7 13 26.00 20 15.07 400 121 4.09 / 429.40 5 26
8 8 0.00 287 15.01 349 1503 5.59 / 430.90 5 137
Average= 5.52
(KJ/cycle)

Cycle 76 GMT 24/10/2023 7:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 17 15.03 464 119 0.12 / 419.80 5 6
2 7 2008.12 40 14.71 3069 1806 1.92 / 421.60 6 22
3 13 1873.12 20 14.69 2914 856 2.78 / 422.46 5 24
4 13 1254.04 20 14.75 2138 631 3.41 / 423.09 5 31
5 13 740.84 20 14.85 1452 431 3.84 / 423.52 5 36
6 13 58.52 20 15.07 453 137 3.98 / 423.66 5 28
7 8 0.12 312 15.01 353 1653 5.63 / 425.31 5 134
Average= 5.52
(KJ/cycle)

Cycle 75 GMT 19/10/2023 6: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 17 15.04 475 121 0.12 / 414.18 5 6
2 7 2009.40 40 14.71 3069 1806 1.93 / 415.99 6 21
3 13 1944.12 20 14.69 2994 880 2.81 / 416.87 5 23
4 13 1263.12 20 14.75 2150 634 3.44 / 417.50 5 32
5 13 628.80 20 14.89 1295 386 3.83 / 417.89 5 36
6 13 90.64 20 15.05 498 150 3.98 / 418.04 5 32
7 13 26.20 20 15.07 400 121 4.10 / 418.16 5 28
8 8 0.12 293 15.00 346 1521 5.62 / 419.68 5 133
Average= 5.52
(KJ/cycle)

Cycle 74 GMT 14/10/2023 4:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 17 15.04 468 120 0.12 / 408.33 6 6
2 7 2009.28 40 14.71 3071 1807 1.93 / 410.14 6 20
3 13 1977.48 20 14.68 3051 896 2.82 / 411.03 5 24
4 13 1507.44 20 14.70 2446 719 3.54 / 411.75 5 27
5 13 856.20 20 14.82 1618 480 4.02 / 412.23 5 35
6 13 56.00 20 15.07 449 135 4.16 / 412.37 5 29
7 13 31.48 20 15.06 414 125 4.28 / 412.49 5 29
8 8 0.00 297 15.00 352 1568 5.85 / 414.06 5 144
Average= 5.52
(KJ/cycle)

Cycle 73 GMT 9/10/2023 2:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 17 15.05 475 122 0.12 / 402.66 6 6
2 7 2008.32 41 14.71 3076 1855 1.98 / 404.52 6 22
3 13 1942.68 20 14.68 3004 882 2.86 / 405.40 5 23
4 13 1249.40 20 14.75 2128 628 3.49 / 406.03 5 30
5 13 764.40 20 14.84 1492 443 3.93 / 406.47 5 36
6 13 72.12 20 15.06 473 142 4.07 / 406.61 5 30
7 13 22.32 20 15.07 392 118 4.19 / 406.73 5 26
8 8 0.04 289 15.01 341 1479 5.67 / 408.21 5 142
Average= 5.52
(KJ/cycle)

Cycle 72 GMT 4/10/2023 1:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 17 15.04 456 117 0.12 / 397.00 6 6
2 7 2006.80 40 14.72 3083 1815 1.93 / 398.81 6 21
3 13 1907.80 20 14.69 2959 869 2.80 / 399.68 5 24
4 13 1394.80 20 14.73 2316 682 3.48 / 400.36 5 27
5 13 656.00 20 14.88 1343 400 3.88 / 400.76 5 37
6 13 91.04 20 15.06 499 150 4.03 / 400.91 5 31
7 13 32.08 20 15.07 411 124 4.16 / 401.04 5 28
8 8 0.08 287 15.01 349 1503 5.66 / 402.54 5 147
Average= 5.51
(KJ/cycle)

Cycle 71 GMT 28/ 9/2023 23:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 17 15.04 465 119 0.12 / 391.28 6 6
2 7 2007.12 40 14.72 3082 1815 1.93 / 393.10 6 21
3 13 1905.08 20 14.69 2964 871 2.80 / 393.97 5 24
4 13 1357.60 20 14.73 2280 672 3.48 / 394.64 5 31
5 13 751.92 20 14.85 1474 438 3.91 / 395.08 5 36
6 13 141.76 20 15.03 581 175 4.09 / 395.25 5 36
7 13 31.92 20 15.06 408 123 4.21 / 395.37 5 30
8 8 -0.04 295 15.01 340 1506 5.72 / 396.88 5 134
Average= 5.51
(KJ/cycle)

Cycle 70 GMT 23/ 9/2023 22: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 17 15.08 452 116 0.12 / 385.75 6 6
2 7 2008.56 40 14.71 3067 1805 1.92 / 387.55 6 21
3 13 1875.00 20 14.68 2923 858 2.78 / 388.41 5 23
4 13 1139.88 20 14.78 1993 589 3.37 / 389.00 5 32
5 13 670.76 20 14.87 1344 400 3.77 / 389.40 5 37
6 13 140.40 20 15.03 573 172 3.94 / 389.57 5 34
7 13 33.04 20 15.06 406 122 4.06 / 389.69 5 29
8 8 -0.04 289 15.01 339 1471 5.53 / 391.16 5 148
Average= 5.51
(KJ/cycle)

Cycle 69 GMT 18/ 9/2023 20:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 17 15.08 455 117 0.12 / 380.14 6 6
2 7 2002.96 40 14.72 3062 1803 1.92 / 381.95 6 20
3 13 1970.52 20 14.68 3026 888 2.81 / 382.84 5 24
4 13 1409.96 20 14.72 2337 688 3.50 / 383.52 5 30
5 13 809.56 20 14.85 1547 459 3.96 / 383.98 5 34
6 13 200.52 20 15.04 645 194 4.15 / 384.18 5 25
7 13 93.40 20 15.07 477 144 4.29 / 384.32 5 22
8 8 0.08 270 15.05 322 1308 5.60 / 385.63 5 143
Average= 5.51
(KJ/cycle)

Cycle 68 GMT 13/ 9/2023 18:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 17 15.07 446 114 0.11 / 374.56 6 6
2 7 2002.72 40 14.72 3063 1803 1.92 / 376.36 6 20
3 13 1937.48 20 14.70 3004 883 2.80 / 377.24 5 24
4 13 1356.28 20 14.74 2254 664 3.47 / 377.91 5 31
5 13 830.24 20 14.84 1576 468 3.93 / 378.38 5 35
6 13 216.24 20 15.04 669 201 4.13 / 378.58 5 29
7 13 72.48 20 15.08 444 134 4.27 / 378.71 5 23
8 8 0.04 272 15.04 322 1317 5.59 / 380.03 5 149
Average= 5.51
(KJ/cycle)

Cycle 67 GMT 8/ 9/2023 17:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 17 15.07 468 120 0.12 / 368.99 6 6
2 7 2003.60 41 14.72 3079 1858 1.98 / 370.85 6 22
3 13 1972.44 20 14.68 3035 891 2.87 / 371.74 5 22
4 13 1295.28 20 14.75 2185 645 3.51 / 372.38 5 31
5 13 739.08 20 14.87 1454 432 3.95 / 372.82 5 35
6 13 153.72 20 15.05 586 176 4.12 / 372.99 5 30
7 13 52.96 20 15.08 423 128 4.25 / 373.12 5 25
8 8 0.00 274 15.04 321 1323 5.57 / 374.44 5 137
Average= 5.51
(KJ/cycle)

Cycle 66 GMT 3/ 9/2023 15:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 17 15.09 449 115 0.12 / 363.41 6 6
2 7 2006.72 40 14.72 3082 1815 1.93 / 365.22 6 22
3 13 1940.68 20 14.69 3015 886 2.82 / 366.11 5 22
4 13 1360.76 20 14.74 2270 669 3.48 / 366.78 5 29
5 13 702.88 20 14.88 1405 418 3.90 / 367.20 5 36
6 13 102.20 20 15.07 509 153 4.06 / 367.35 5 29
7 13 36.40 20 15.08 408 123 4.18 / 367.47 5 26
8 8 0.32 278 15.03 334 1396 5.58 / 368.87 5 139
Average= 5.51
(KJ/cycle)

Cycle 65 GMT 29/ 8/2023 14:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 17 15.06 457 117 0.12 / 357.88 6 6
2 7 2003.36 40 14.73 3073 1811 1.93 / 359.69 6 22
3 13 1971.24 20 14.69 3042 894 2.82 / 360.59 5 22
4 13 1243.92 20 14.77 2135 631 3.45 / 361.22 5 31
5 13 707.56 20 14.88 1415 421 3.87 / 361.64 5 36
6 13 119.80 20 15.07 539 162 4.04 / 361.80 5 29
7 13 52.64 20 15.08 427 129 4.16 / 361.93 5 27
8 8 -0.20 276 15.04 329 1366 5.53 / 363.29 5 139
Average= 5.50
(KJ/cycle)

Cycle 64 GMT 24/ 8/2023 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 17 15.07 452 116 0.12 / 352.26 6 6
2 7 2008.64 40 14.73 3083 1817 1.93 / 354.07 6 21
3 13 1942.64 20 14.69 3000 881 2.81 / 354.96 5 24
4 13 1500.24 20 14.71 2462 724 3.54 / 355.68 5 27
5 13 688.20 20 14.89 1380 411 3.95 / 356.09 5 35
6 13 156.56 20 15.06 586 177 4.13 / 356.27 5 29
7 13 85.80 20 15.07 477 144 4.27 / 356.41 5 27
8 8 0.08 276 15.04 326 1353 5.62 / 357.76 5 155
Average= 5.50
(KJ/cycle)

Cycle 63 GMT 19/ 8/2023 11: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 17 15.08 447 115 0.11 / 346.56 6 6
2 7 2010.04 41 14.72 3087 1863 1.98 / 348.42 6 22
3 13 1875.96 20 14.70 2912 856 2.83 / 349.28 5 23
4 13 1237.00 20 14.77 2116 625 3.46 / 349.90 5 31
5 13 795.48 20 14.85 1546 459 3.92 / 350.36 5 36
6 13 318.60 20 15.00 843 253 4.17 / 350.61 5 34
7 13 72.92 20 15.08 456 138 4.31 / 350.75 5 26
8 8 -0.04 278 15.04 333 1392 5.70 / 352.14 5 155
Average= 5.50
(KJ/cycle)

Cycle 62 GMT 14/ 8/2023 9:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 17 15.09 430 110 0.11 / 341.01 6 6
2 7 2010.92 40 14.73 3077 1813 1.92 / 342.82 6 22
3 13 1978.04 20 14.70 3043 895 2.82 / 343.72 5 24
4 13 1272.72 20 14.77 2162 639 3.46 / 344.36 5 30
5 13 787.08 20 14.87 1517 451 3.91 / 344.81 5 35
6 13 126.84 20 15.08 548 165 4.07 / 344.97 5 27
7 13 62.60 20 15.09 441 133 4.21 / 345.11 5 25
8 8 -0.12 274 15.05 324 1336 5.54 / 346.44 5 131
Average= 5.50
(KJ/cycle)

Cycle 61 GMT 9/ 8/2023 7:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 17 15.07 453 116 0.12 / 335.44 6 6
2 7 2009.24 40 14.73 3084 1817 1.93 / 337.26 6 21
3 13 1976.64 20 14.71 3050 897 2.83 / 338.16 5 21
4 13 1198.72 20 14.79 2072 613 3.44 / 338.77 5 31
5 13 942.64 20 14.82 1734 514 3.96 / 339.28 5 35
6 13 125.36 20 15.08 539 163 4.12 / 339.45 5 29
7 13 31.88 20 15.10 390 118 4.24 / 339.56 5 25
8 8 0.08 278 15.05 319 1335 5.57 / 340.90 5 158
Average= 5.50
(KJ/cycle)

Cycle 60 GMT 4/ 8/2023 6:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 17 15.08 462 118 0.12 / 329.78 6 6
2 7 2002.28 40 14.73 3069 1808 1.93 / 331.59 6 20
3 13 1902.64 20 14.72 2949 868 2.79 / 332.46 5 24
4 13 1428.44 20 14.74 2373 700 3.49 / 333.16 5 30
5 13 859.04 20 14.85 1613 479 3.97 / 333.64 5 36
6 13 124.84 20 15.08 543 164 4.14 / 333.80 5 30
7 13 31.16 20 15.10 394 119 4.26 / 333.92 5 25
8 8 0.04 282 15.05 332 1409 5.67 / 335.33 5 153
Average= 5.50
(KJ/cycle)

Cycle 59 GMT 30/ 7/2023 4:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 17 15.08 448 115 0.11 / 324.23 6 6
2 7 2004.20 40 14.75 3062 1807 1.92 / 326.04 6 21
3 13 1870.24 20 14.72 2914 858 2.78 / 326.89 5 24
4 13 1386.96 20 14.76 2306 681 3.46 / 327.58 5 29
5 13 701.36 20 14.90 1407 419 3.88 / 327.99 5 37
6 13 98.24 20 15.09 506 153 4.03 / 328.15 5 29
7 13 36.04 20 15.10 404 122 4.15 / 328.27 5 25
8 8 0.04 282 15.05 328 1392 5.55 / 329.66 5 150
Average= 5.49
(KJ/cycle)

Cycle 58 GMT 25/ 7/2023 3: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 17 15.09 445 114 0.11 / 318.61 6 6
2 7 2003.68 40 14.75 3065 1808 1.92 / 320.41 6 22
3 13 1971.28 20 14.71 3046 896 2.82 / 321.31 5 23
4 13 1388.24 20 14.76 2316 684 3.50 / 321.99 5 29
5 13 792.12 20 14.88 1537 457 3.96 / 322.45 5 35
6 13 134.92 20 15.08 554 167 4.13 / 322.62 5 30
7 13 35.00 20 15.11 394 119 4.25 / 322.74 5 25
8 8 0.08 278 15.06 329 1377 5.62 / 324.12 5 145
Average= 5.49
(KJ/cycle)

Cycle 57 GMT 20/ 7/2023 1:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 17 15.09 453 116 0.12 / 313.14 6 6
2 7 2011.92 40 14.74 3070 1810 1.93 / 314.95 6 21
3 13 1980.40 20 14.70 3039 893 2.82 / 315.84 5 23
4 13 1238.04 20 14.79 2129 630 3.45 / 316.47 5 31
5 13 695.48 20 14.91 1382 412 3.86 / 316.88 5 37
6 13 102.76 20 15.10 513 155 4.02 / 317.04 5 28
7 13 39.08 20 15.11 399 121 4.14 / 317.16 5 24
8 8 0.16 274 15.07 323 1334 5.47 / 318.49 5 138
Average= 5.49
(KJ/cycle)

Cycle 56 GMT 14/ 7/2023 23:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 17 15.09 465 119 0.12 / 307.63 6 6
2 7 2004.28 40 14.74 3071 1811 1.93 / 309.44 6 23
3 13 1938.40 20 14.72 3004 884 2.81 / 310.33 5 22
4 13 1285.28 20 14.79 2179 645 3.46 / 310.97 5 31
5 13 663.40 20 14.92 1347 402 3.86 / 311.37 5 36
6 13 135.88 20 15.09 557 168 4.03 / 311.54 5 29
7 13 38.16 20 15.11 406 123 4.15 / 311.66 5 24
8 8 0.08 274 15.07 329 1359 5.51 / 313.02 5 152
Average= 5.49
(KJ/cycle)

Cycle 55 GMT 9/ 7/2023 22:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 15 15.10 444 101 0.10 / 301.93 6 6
2 3 1563.28 2 14.98 2563 77 0.18 / 302.01 5 22
3 7 2011.92 40 14.73 3092 1822 2.00 / 303.83 22 22
4 13 1979.96 20 14.71 3074 904 2.90 / 304.73 5 24
5 13 1317.84 20 14.78 2221 657 3.56 / 305.39 5 29
6 13 692.52 20 14.90 1401 417 3.98 / 305.81 5 37
7 13 92.88 20 15.10 503 152 4.13 / 305.96 5 28
8 13 30.76 20 15.11 400 121 4.25 / 306.08 5 25
9 8 -0.16 282 15.06 337 1431 5.68 / 307.51 5 150
Average= 5.49
(KJ/cycle)

Cycle 54 GMT 4/ 7/2023 20:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 17 15.10 454 117 0.12 / 296.31 6 6
2 3 1467.68 -1 15.45 0 0 0.00 / 296.31 6 6
3 7 2006.48 40 14.75 3073 1813 1.93 / 298.12 6 21
4 13 1940.44 20 14.72 3002 884 2.81 / 299.00 5 23
5 13 1408.60 20 14.77 2348 694 3.51 / 299.70 5 29
6 13 841.72 20 14.87 1602 476 3.98 / 300.17 5 35
7 13 117.08 20 15.10 526 159 4.14 / 300.33 5 28
8 13 49.80 20 15.11 422 128 4.27 / 300.46 5 26
9 8 0.08 276 15.07 329 1368 5.64 / 301.83 5 133
Average= 5.49
(KJ/cycle)

Cycle 53 GMT 29/ 6/2023 19: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 17 15.07 470 120 0.12 / 290.75 6 6
2 7 2004.28 40 14.75 3084 1820 1.94 / 292.57 6 21
3 13 1937.48 20 14.74 2993 882 2.82 / 293.45 5 23
4 13 1317.72 20 14.79 2226 658 3.48 / 294.11 5 31
5 13 727.76 20 14.91 1438 429 3.91 / 294.54 5 36
6 13 151.20 20 15.09 584 176 4.09 / 294.71 5 31
7 13 23.48 20 15.13 377 114 4.20 / 294.83 5 24
8 8 2.64 278 15.07 326 1366 5.57 / 296.19 5 141
Average= 5.49
(KJ/cycle)

Cycle 52 GMT 24/ 6/2023 17:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 17 15.10 450 116 0.12 / 285.09 6 6
2 7 2004.20 40 14.76 3076 1816 1.93 / 286.90 6 22
3 13 1972.40 20 14.72 3040 895 2.83 / 287.80 5 24
4 13 1222.88 20 14.81 2117 627 3.45 / 288.43 5 32
5 13 640.00 20 14.93 1325 396 3.85 / 288.82 5 38
6 13 103.64 20 15.10 530 160 4.01 / 288.98 5 35
7 13 16.24 20 15.12 384 116 4.13 / 289.10 5 28
8 8 -0.16 295 15.05 344 1527 5.65 / 290.63 5 133
Average= 5.48
(KJ/cycle)

Cycle 51 GMT 19/ 6/2023 15:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 17 15.12 446 115 0.11 / 279.50 6 6
2 7 2009.60 40 14.75 3082 1818 1.93 / 281.32 6 22
3 13 1976.72 20 14.72 3049 898 2.83 / 282.22 5 24
4 13 1260.40 20 14.81 2155 638 3.47 / 282.86 5 28
5 13 782.28 20 14.89 1525 454 3.92 / 283.31 5 36
6 13 102.92 20 15.11 507 153 4.08 / 283.46 5 28
7 13 36.84 20 15.12 401 121 4.20 / 283.59 5 25
8 8 0.04 278 15.08 331 1388 5.59 / 284.97 5 155
Average= 5.48
(KJ/cycle)

Cycle 50 GMT 14/ 6/2023 13:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 17 15.12 445 114 0.11 / 274.09 6 6
2 7 2006.16 40 14.75 3076 1815 1.93 / 275.91 6 22
3 13 1873.00 20 14.73 2936 865 2.79 / 276.77 5 25
4 13 1270.76 20 14.81 2160 640 3.43 / 277.41 5 31
5 13 656.68 20 14.95 1338 400 3.83 / 277.81 5 34
6 13 198.00 20 15.10 638 193 4.03 / 278.00 5 26
7 13 29.64 20 15.14 377 114 4.14 / 278.12 5 19
8 8 0.12 267 15.10 315 1270 5.41 / 279.39 5 138
Average= 5.48
(KJ/cycle)

Cycle 49 GMT 9/ 6/2023 12:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 17 15.11 459 118 0.12 / 268.53 6 6
2 7 2005.84 40 14.76 3078 1817 1.94 / 270.35 6 22
3 13 1939.28 20 14.73 3000 884 2.82 / 271.23 5 23
4 13 1286.16 20 14.81 2193 650 3.47 / 271.88 5 29
5 13 843.68 20 14.89 1602 477 3.95 / 272.36 5 36
6 13 201.36 20 15.10 652 197 4.14 / 272.56 5 26
7 13 59.92 20 15.14 423 128 4.27 / 272.68 5 21
8 8 0.12 270 15.10 317 1292 5.56 / 273.98 5 139
Average= 5.48
(KJ/cycle)

Cycle 48 GMT 4/ 6/2023 10:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 17 15.09 471 121 0.12 / 263.02 5 6
2 7 2004.32 40 14.76 3074 1815 1.94 / 264.84 6 22
3 13 1938.76 20 14.74 3005 886 2.82 / 265.72 5 24
4 13 1186.84 20 14.84 2059 611 3.43 / 266.34 5 32
5 13 720.68 20 14.93 1423 425 3.86 / 266.76 5 37
6 13 156.40 20 15.11 577 174 4.03 / 266.93 5 26
7 13 88.04 20 15.13 466 141 4.17 / 267.08 5 24
8 8 0.04 272 15.09 326 1338 5.51 / 268.41 5 137
Average= 5.48
(KJ/cycle)

Cycle 47 GMT 30/ 5/2023 9: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 17 15.11 459 118 0.12 / 257.20 5 6
2 7 2002.92 40 14.77 3068 1813 1.93 / 259.01 6 21
3 13 1799.96 20 14.76 2820 832 2.76 / 259.84 5 24
4 13 1515.44 20 14.77 2457 726 3.49 / 260.57 5 28
5 13 899.56 20 14.88 1678 499 3.99 / 261.07 5 36
6 13 231.64 20 15.07 717 216 4.20 / 261.29 5 36
7 8 0.12 310 15.08 346 1617 5.82 / 262.90 5 135
Average= 5.48
(KJ/cycle)

Cycle 46 GMT 25/ 5/2023 7:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 17 15.11 450 116 0.12 / 251.57 6 6
2 7 2007.24 40 14.77 3065 1811 1.93 / 253.38 6 21
3 13 1908.48 20 14.75 2962 874 2.80 / 254.25 5 21
4 13 1305.92 20 14.81 2198 651 3.45 / 254.90 5 29
5 13 847.16 20 14.89 1603 477 3.93 / 255.38 5 36
6 13 107.36 20 15.12 517 156 4.08 / 255.54 5 31
7 13 16.44 20 15.14 367 111 4.20 / 255.65 5 25
8 8 -0.08 289 15.08 329 1434 5.63 / 257.08 5 148
Average= 5.47
(KJ/cycle)

Cycle 45 GMT 20/ 5/2023 5:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 17 15.13 444 114 0.11 / 246.02 6 6
2 7 2004.28 40 14.77 3068 1813 1.93 / 247.83 6 20
3 13 1937.84 20 14.74 2998 884 2.81 / 248.72 5 23
4 13 1108.08 20 14.86 1951 580 3.39 / 249.30 5 32
5 13 764.24 20 14.92 1497 447 3.84 / 249.75 5 37
6 13 162.92 20 15.11 602 182 4.02 / 249.93 5 30
7 13 55.16 20 15.13 434 131 4.15 / 250.06 5 26
8 8 0.00 278 15.09 332 1393 5.54 / 251.45 5 141
Average= 5.47
(KJ/cycle)

Cycle 44 GMT 15/ 5/2023 4: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 17 15.12 465 120 0.12 / 240.41 6 6
2 7 2007.12 40 14.78 3072 1816 1.94 / 242.23 6 20
3 13 1839.32 20 14.77 2900 857 2.79 / 243.08 5 23
4 13 1317.80 20 14.82 2236 663 3.46 / 243.75 5 30
5 13 870.08 20 14.90 1636 488 3.94 / 244.23 5 35
6 13 249.04 20 15.09 723 218 4.16 / 244.45 5 30
7 13 98.60 20 15.13 486 147 4.31 / 244.60 5 25
8 8 0.08 274 15.11 316 1308 5.62 / 245.91 5 149
Average= 5.46
(KJ/cycle)

Cycle 43 GMT 10/ 5/2023 2:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 17 15.12 461 118 0.12 / 234.87 5 6
2 7 2009.84 40 14.78 3076 1819 1.94 / 236.68 6 20
3 13 1877.76 20 14.76 2949 871 2.81 / 237.56 5 23
4 13 1219.00 20 14.85 2086 620 3.43 / 238.17 5 31
5 13 806.48 20 14.92 1544 461 3.89 / 238.64 5 36
6 13 121.44 20 15.13 531 161 4.05 / 238.80 5 28
7 8 0.20 302 15.10 328 1496 5.54 / 240.29 5 153
Average= 5.46
(KJ/cycle)

Cycle 42 GMT 5/ 5/2023 0:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 17 15.10 461 118 0.12 / 229.07 5 6
2 7 2005.68 41 14.78 3065 1857 1.98 / 230.93 6 22
3 13 1905.84 20 14.77 2942 869 2.84 / 231.80 5 22
4 13 1500.92 20 14.79 2450 725 3.57 / 232.52 5 29
5 13 982.96 20 14.87 1788 532 4.10 / 233.05 5 34
6 13 133.40 20 15.13 557 169 4.27 / 233.22 5 31
7 8 0.12 308 15.10 328 1525 5.80 / 234.75 5 135
Average= 5.46
(KJ/cycle)

Cycle 41 GMT 29/ 4/2023 23:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 17 15.11 478 123 0.12 / 223.42 5 6
2 7 2008.72 40 14.78 3066 1813 1.94 / 225.23 6 21
3 13 1908.60 20 14.76 2962 874 2.81 / 226.11 5 24
4 13 1252.28 20 14.84 2142 636 3.45 / 226.74 5 30
5 13 725.56 20 14.94 1447 432 3.88 / 227.18 5 37
6 13 94.48 20 15.13 506 153 4.03 / 227.33 5 34
7 13 14.60 20 15.15 375 114 4.14 / 227.44 5 25
8 8 -0.04 297 15.09 337 1510 5.65 / 228.95 5 146
Average= 5.45
(KJ/cycle)

Cycle 40 GMT 24/ 4/2023 21:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 17 15.13 462 119 0.12 / 217.77 6 6
2 7 2007.32 40 14.79 3076 1820 1.94 / 219.59 6 21
3 13 1976.28 20 14.76 3038 897 2.84 / 220.49 5 21
4 13 1323.24 20 14.83 2231 662 3.50 / 221.15 5 30
5 13 703.28 20 14.96 1406 421 3.92 / 221.57 5 37
6 13 131.72 20 15.13 554 168 4.09 / 221.74 5 31
7 13 13.52 20 15.16 372 113 4.20 / 221.85 5 25
8 8 -0.04 287 15.10 334 1447 5.65 / 223.30 5 133
Average= 5.45
(KJ/cycle)

Cycle 39 GMT 19/ 4/2023 20:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 17 15.14 448 115 0.12 / 212.10 6 6
2 7 2007.40 40 14.79 3070 1816 1.93 / 213.92 6 19
3 13 1974.48 20 14.76 3060 903 2.83 / 214.82 5 23
4 13 1423.64 20 14.81 2361 699 3.53 / 215.52 5 29
5 13 805.80 20 14.93 1551 463 4.00 / 215.98 5 36
6 13 155.36 20 15.13 596 180 4.18 / 216.16 5 29
7 8 0.08 300 15.12 328 1488 5.67 / 217.65 5 135
Average= 5.44
(KJ/cycle)

Cycle 38 GMT 14/ 4/2023 18:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 17 15.14 452 116 0.12 / 206.48 6 6
2 7 2003.20 40 14.79 3073 1818 1.93 / 208.29 6 20
3 13 1937.24 20 14.77 2981 881 2.81 / 209.17 5 22
4 13 1415.20 20 14.81 2346 695 3.51 / 209.87 5 30
5 13 779.64 20 14.95 1509 451 3.96 / 210.32 5 34
6 13 278.32 20 15.10 767 232 4.19 / 210.55 5 29
7 13 89.64 20 15.16 466 141 4.33 / 210.69 5 23
8 8 0.12 274 15.13 312 1293 5.63 / 211.99 5 166
Average= 5.44
(KJ/cycle)

Cycle 37 GMT 9/ 4/2023 17:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 17 15.13 460 118 0.12 / 200.97 5 6
2 7 2006.72 40 14.80 3065 1814 1.93 / 202.79 6 20
3 13 1837.56 20 14.79 2867 848 2.78 / 203.63 5 24
4 13 1192.20 20 14.86 2062 613 3.39 / 204.25 5 31
5 13 782.00 20 14.94 1517 453 3.85 / 204.70 5 35
6 13 168.76 20 15.13 614 186 4.03 / 204.89 5 29
7 13 29.32 20 15.17 383 116 4.15 / 205.00 5 22
8 8 0.08 276 15.12 325 1356 5.51 / 206.36 5 153
Average= 5.43
(KJ/cycle)

Cycle 36 GMT 4/ 4/2023 15:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 17 15.15 463 119 0.12 / 195.35 6 6
2 7 2003.16 40 14.79 3073 1818 1.94 / 197.17 6 21
3 13 1970.96 20 14.77 3036 897 2.83 / 198.07 5 23
4 13 1374.68 20 14.83 2300 682 3.52 / 198.75 5 28
5 13 704.80 20 14.97 1412 423 3.94 / 199.17 5 36
6 13 106.64 20 15.16 515 156 4.10 / 199.33 5 28
7 8 -0.12 306 15.12 330 1527 5.62 / 200.85 5 146
Average= 5.43
(KJ/cycle)

Cycle 35 GMT 30/ 3/2023 13:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 17 15.15 460 118 0.12 / 189.78 6 6
2 7 2006.88 40 14.79 3067 1814 1.93 / 191.60 6 20
3 13 1841.80 20 14.79 2887 854 2.79 / 192.45 5 24
4 13 1395.64 20 14.83 2318 688 3.47 / 193.14 5 30
5 13 789.48 20 14.95 1521 455 3.93 / 193.60 5 35
6 13 113.20 20 15.16 517 157 4.09 / 193.75 5 26
7 8 0.12 300 15.13 326 1480 5.57 / 195.23 5 155
Average= 5.42
(KJ/cycle)

Cycle 34 GMT 25/ 3/2023 12:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 17 15.14 473 122 0.12 / 184.15 5 6
2 7 2007.28 41 14.80 3075 1866 1.99 / 186.01 6 20
3 13 1942.28 20 14.77 2999 886 2.87 / 186.90 5 24
4 13 1265.96 20 14.86 2164 643 3.52 / 187.54 5 30
5 13 855.72 20 14.93 1616 483 4.00 / 188.02 5 35
6 13 150.64 20 15.15 584 177 4.18 / 188.20 5 30
7 8 0.08 300 15.13 323 1466 5.64 / 189.67 5 145
Average= 5.42
(KJ/cycle)

Cycle 33 GMT 20/ 3/2023 10:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 17 15.14 455 117 0.12 / 178.56 6 6
2 7 2003.44 40 14.81 3058 1812 1.93 / 180.37 6 20
3 13 1938.20 20 14.78 3017 892 2.82 / 181.26 5 22
4 13 1286.04 20 14.86 2186 650 3.47 / 181.91 5 31
5 13 672.68 20 14.99 1366 410 3.88 / 182.32 5 35
6 13 143.00 20 15.15 566 171 4.05 / 182.50 5 30
7 13 18.48 20 15.18 373 113 4.16 / 182.61 5 23
8 8 0.00 282 15.12 332 1416 5.58 / 184.02 5 145
Average= 5.41
(KJ/cycle)

Cycle 32 GMT 15/ 3/2023 8:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 16 15.15 485 118 0.12 / 172.95 6 6
2 7 2004.60 40 14.81 3078 1823 1.94 / 174.77 6 21
3 13 1939.36 20 14.78 3016 892 2.83 / 175.66 5 23
4 13 1322.56 20 14.85 2241 666 3.50 / 176.33 5 29
5 13 796.20 20 14.95 1537 460 3.96 / 176.79 5 36
6 13 118.12 20 15.17 523 159 4.12 / 176.94 5 28
7 13 46.08 20 15.17 418 127 4.24 / 177.07 5 25
8 8 0.12 280 15.13 324 1373 5.62 / 178.44 5 134
Average= 5.41
(KJ/cycle)

Cycle 31 GMT 10/ 3/2023 7: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 16 15.15 481 117 0.12 / 167.48 5 6
2 7 2004.52 40 14.80 3083 1825 1.94 / 169.30 6 21
3 13 1870.96 20 14.79 2938 869 2.81 / 170.17 5 22
4 13 1180.64 20 14.88 2051 610 3.42 / 170.78 5 31
5 13 574.08 20 15.03 1224 368 3.79 / 171.15 5 36
6 13 134.56 20 15.16 561 170 3.96 / 171.32 5 27
7 13 13.52 20 15.19 372 113 4.07 / 171.43 5 23
8 8 0.00 276 15.13 334 1395 5.47 / 172.83 5 144
Average= 5.40
(KJ/cycle)

Cycle 30 GMT 5/ 3/2023 5:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 16 15.16 460 112 0.11 / 161.93 5 6
2 7 2008.16 40 14.80 3074 1820 1.93 / 163.75 6 21
3 13 1871.56 20 14.80 2910 861 2.79 / 164.61 5 23
4 13 1218.20 20 14.88 2103 626 3.42 / 165.24 5 31
5 13 676.88 20 14.99 1371 411 3.83 / 165.65 5 37
6 13 149.00 20 15.15 590 179 4.01 / 165.83 5 30
7 8 0.04 300 15.13 338 1534 5.54 / 167.36 5 136
Average= 5.40
(KJ/cycle)

Cycle 29 GMT 28/ 2/2023 3:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 16 15.15 467 113 0.11 / 156.34 5 6
2 7 2007.36 40 14.81 3083 1826 1.94 / 158.17 6 21
3 13 1974.76 20 14.79 3060 905 2.84 / 159.07 5 24
4 13 1275.36 20 14.87 2188 651 3.50 / 159.72 5 31
5 13 727.60 20 14.98 1445 433 3.93 / 160.16 5 38
6 13 132.84 20 15.16 552 167 4.10 / 160.32 5 29
7 8 0.04 302 15.14 327 1495 5.59 / 161.82 5 145
Average= 5.39
(KJ/cycle)

Cycle 28 GMT 23/ 2/2023 1:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 16 15.15 475 115 0.12 / 150.76 5 6
2 7 2010.28 40 14.81 3082 1826 1.94 / 152.58 6 22
3 13 1845.64 20 14.81 2893 857 2.80 / 153.44 5 24
4 13 1407.28 20 14.85 2337 694 3.49 / 154.13 5 30
5 13 666.44 20 15.00 1362 409 3.90 / 154.54 5 37
6 13 140.36 20 15.16 575 174 4.07 / 154.72 5 30
7 8 0.04 306 15.14 326 1510 5.59 / 156.23 5 147
Average= 5.39
(KJ/cycle)

Cycle 27 GMT 17/ 2/2023 23:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 16 15.16 470 114 0.11 / 145.11 5 6
2 7 2005.72 40 14.82 3075 1823 1.94 / 146.93 6 21
3 13 1905.88 20 14.81 2958 876 2.81 / 147.81 5 24
4 13 1305.00 20 14.88 2205 656 3.47 / 148.46 5 30
5 13 746.92 20 14.98 1477 443 3.91 / 148.91 5 37
6 13 160.80 20 15.16 609 185 4.10 / 149.09 5 33
7 8 -0.08 308 15.14 333 1553 5.65 / 150.64 5 147
Average= 5.38
(KJ/cycle)

Cycle 26 GMT 12/ 2/2023 22:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 16 15.17 464 113 0.11 / 139.47 5 6
2 7 2006.72 40 14.82 3070 1820 1.93 / 141.28 6 22
3 13 1906.20 20 14.81 2942 871 2.80 / 142.16 5 25
4 13 1463.24 20 14.84 2410 715 3.52 / 142.87 5 29
5 13 818.88 20 14.96 1568 469 3.99 / 143.34 5 36
6 13 131.44 20 15.18 560 170 4.16 / 143.51 5 28
7 8 0.04 300 15.16 326 1483 5.64 / 144.99 5 138
Average= 5.37
(KJ/cycle)

Cycle 25 GMT 7/ 2/2023 20:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 16 15.18 464 113 0.11 / 133.95 6 6
2 7 2012.12 40 14.82 3083 1828 1.94 / 135.78 6 22
3 13 1979.52 20 14.79 3058 905 2.84 / 136.68 5 23
4 13 1231.96 20 14.90 2118 631 3.48 / 137.32 5 31
5 13 643.44 20 15.02 1325 398 3.87 / 137.71 5 36
6 13 148.20 20 15.17 576 175 4.05 / 137.89 5 30
7 8 0.04 300 15.16 322 1464 5.51 / 139.35 5 140
Average= 5.36
(KJ/cycle)

Cycle 24 GMT 2/ 2/2023 19:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 16 15.18 461 112 0.11 / 128.32 6 6
2 7 2008.64 40 14.83 3087 1831 1.94 / 130.16 6 21
3 13 1942.96 20 14.83 2988 886 2.83 / 131.04 5 22
4 13 1285.92 20 14.89 2189 652 3.48 / 131.69 5 31
5 13 835.40 20 14.97 1594 477 3.96 / 132.17 5 36
6 13 212.12 20 15.16 675 205 4.16 / 132.38 5 32
7 8 -0.04 297 15.16 325 1463 5.63 / 133.84 5 137
Average= 5.35
(KJ/cycle)

Cycle 23 GMT 28/ 1/2023 17:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 16 15.18 448 109 0.11 / 122.83 6 6
2 7 2010.28 40 14.82 3089 1831 1.94 / 124.66 6 21
3 13 1875.08 20 14.83 2932 870 2.81 / 125.53 5 24
4 13 1250.68 20 14.90 2136 637 3.45 / 126.17 5 32
5 13 712.60 20 15.01 1425 428 3.87 / 126.60 5 35
6 13 136.24 20 15.19 554 168 4.04 / 126.77 5 27
7 8 0.04 295 15.17 323 1445 5.49 / 128.21 5 146
Average= 5.34
(KJ/cycle)

Cycle 22 GMT 23/ 1/2023 16: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 16 15.18 466 113 0.11 / 117.35 6 6
2 7 2004.88 40 14.84 3078 1827 1.94 / 119.18 6 22
3 13 1837.04 20 14.84 2873 853 2.79 / 120.03 5 23
4 13 1354.24 20 14.87 2284 679 3.47 / 120.71 5 30
5 13 648.40 20 15.03 1334 401 3.87 / 121.11 5 36
6 13 152.24 20 15.19 577 175 4.05 / 121.29 5 28
7 13 20.28 20 15.22 365 111 4.16 / 121.40 5 23
8 8 0.08 274 15.17 319 1326 5.49 / 122.72 5 143
Average= 5.34
(KJ/cycle)

Cycle 21 GMT 18/ 1/2023 14:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 16 15.19 467 113 0.11 / 111.63 5 6
2 7 2004.12 41 14.84 3081 1875 1.99 / 113.50 6 21
3 13 1865.56 20 14.84 2924 868 2.86 / 114.37 5 24
4 13 1539.08 20 14.85 2513 746 3.60 / 115.12 5 28
5 13 757.96 20 15.01 1494 448 4.05 / 115.56 5 36
6 13 175.76 20 15.18 623 189 4.24 / 115.75 5 30
7 13 29.52 20 15.22 386 117 4.36 / 115.87 5 24
8 8 -0.04 276 15.17 327 1369 5.73 / 117.24 5 143
Average= 5.33
(KJ/cycle)

Cycle 20 GMT 13/ 1/2023 13: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 16 15.18 456 111 0.11 / 106.05 5 6
2 7 2006.20 41 14.84 3078 1873 1.98 / 107.92 5 21
3 13 1870.16 20 14.84 2936 871 2.85 / 108.79 5 24
4 13 1239.96 20 14.91 2134 636 3.49 / 109.43 5 31
5 13 749.16 20 15.01 1475 443 3.93 / 109.87 5 36
6 13 160.60 20 15.19 594 180 4.11 / 110.05 5 31
7 8 0.24 297 15.17 324 1460 5.57 / 111.51 5 137
Average= 5.31
(KJ/cycle)

Cycle 19 GMT 8/ 1/2023 11:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 16 15.20 452 110 0.11 / 100.48 6 6
2 7 2009.08 40 14.85 3079 1829 1.94 / 102.31 6 21
3 13 1942.68 20 14.83 2995 888 2.83 / 103.19 5 23
4 13 1299.64 20 14.91 2213 660 3.49 / 103.85 5 30
5 13 683.60 20 15.03 1385 416 3.90 / 104.27 5 37
6 13 165.04 20 15.19 599 182 4.09 / 104.45 5 32
7 13 95.64 20 15.20 487 148 4.23 / 104.60 5 29
8 8 0.00 274 15.17 322 1338 5.57 / 105.94 5 138
Average= 5.30
(KJ/cycle)

Cycle 18 GMT 3/ 1/2023 9:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 16 15.18 472 115 0.11 / 95.49 5 6
2 7 1599.08 40 14.96 2586 1547 1.66 / 97.04 6 25
3 13 1575.96 20 14.95 2553 763 2.43 / 97.80 5 27
4 13 1173.12 20 14.98 2042 612 3.04 / 98.41 5 32
5 13 538.16 20 15.10 1171 354 3.39 / 98.77 5 38
6 13 145.00 20 15.22 576 175 3.57 / 98.94 5 31
7 8 0.08 291 15.20 322 1424 4.99 / 100.37 5 157
Average= 5.28
(KJ/cycle)

Cycle 17 GMT 29/12/2022 8:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 16 15.19 476 116 0.12 / 90.01 5 6
2 7 2004.68 40 14.85 3082 1831 1.95 / 91.84 6 21
3 13 1764.52 20 14.87 2802 833 2.78 / 92.67 5 24
4 13 1270.88 20 14.91 2178 649 3.43 / 93.32 5 31
5 13 640.40 20 15.04 1324 398 3.83 / 93.72 5 37
6 13 142.48 20 15.20 571 174 4.00 / 93.89 5 32
7 8 0.08 295 15.18 331 1482 5.48 / 95.38 5 145
Average= 5.30
(KJ/cycle)

Cycle 16 GMT 24/12/2022 7: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 16 15.20 463 113 0.11 / 84.45 5 6
2 7 1997.28 41 14.86 3070 1870 1.98 / 86.32 6 21
3 13 1751.76 20 14.87 2781 827 2.81 / 87.15 5 25
4 13 1340.56 20 14.90 2267 676 3.49 / 87.83 5 30
5 13 716.84 20 15.03 1434 431 3.92 / 88.26 5 36
6 13 97.16 20 15.21 505 154 4.07 / 88.41 5 30
7 8 0.04 295 15.18 331 1482 5.55 / 89.89 5 133
Average= 5.29
(KJ/cycle)

Cycle 15 GMT 19/12/2022 5:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 16 15.21 441 107 0.11 / 78.86 6 6
2 7 2004.60 40 14.86 3080 1831 1.94 / 80.69 6 21
3 13 1937.76 20 14.84 3025 898 2.84 / 81.59 5 23
4 13 1210.64 20 14.94 2093 625 3.46 / 82.22 5 31
5 13 735.08 20 15.03 1456 438 3.90 / 82.65 5 36
6 13 112.92 20 15.22 535 163 4.06 / 82.82 5 30
7 13 44.44 20 15.23 418 127 4.19 / 82.95 5 27
8 8 0.04 276 15.18 333 1395 5.58 / 84.34 5 157
Average= 5.27
(KJ/cycle)

Cycle 14 GMT 14/12/2022 3:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 16 15.21 458 111 0.11 / 73.34 6 6
2 7 2008.16 40 14.86 3076 1828 1.94 / 75.17 6 22
3 13 1908.84 20 14.86 2987 888 2.83 / 76.06 5 23
4 13 1354.48 20 14.91 2277 679 3.51 / 76.74 5 30
5 13 718.20 20 15.04 1435 432 3.94 / 77.17 5 35
6 13 135.36 20 15.22 556 169 4.11 / 77.34 5 28
7 13 15.80 20 15.24 358 109 4.22 / 77.45 5 22
8 8 -0.04 270 15.19 319 1308 5.52 / 78.76 5 147
Average= 5.25
(KJ/cycle)

Cycle 13 GMT 9/12/2022 2: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 16 15.21 453 110 0.11 / 67.83 6 6
2 7 2011.16 40 14.87 3102 1845 1.96 / 69.67 6 21
3 13 1978.60 20 14.84 3050 905 2.86 / 70.58 5 22
4 13 1246.16 20 14.94 2147 642 3.50 / 71.22 5 31
5 13 712.40 20 15.04 1420 427 3.93 / 71.65 5 36
6 13 103.36 20 15.23 502 153 4.08 / 71.80 5 28
7 13 18.04 20 15.25 364 111 4.19 / 71.91 5 24
8 8 0.04 272 15.20 319 1319 5.51 / 73.23 5 148
Average= 5.23
(KJ/cycle)

Cycle 12 GMT 4/12/2022 0:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 16 15.21 466 113 0.11 / 62.28 5 6
2 7 2007.00 41 14.87 3082 1879 1.99 / 64.16 6 21
3 13 1974.12 20 14.85 3059 909 2.90 / 65.06 5 22
4 13 1218.04 20 14.95 2109 631 3.53 / 65.69 5 31
5 13 709.24 20 15.05 1424 429 3.96 / 66.12 5 36
6 13 102.48 20 15.23 505 154 4.11 / 66.28 5 29
7 8 0.16 291 15.20 326 1442 5.56 / 67.72 5 136
Average= 5.21
(KJ/cycle)

Cycle 11 GMT 28/11/2022 23: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 16 15.20 474 115 0.12 / 56.67 6 6
2 7 2011.00 40 14.88 3081 1834 1.95 / 58.50 6 21
3 13 1945.28 20 14.86 3006 893 2.84 / 59.40 5 23
4 13 1496.04 20 14.89 2459 732 3.57 / 60.13 5 29
5 13 656.68 20 15.07 1345 405 3.98 / 60.54 5 36
6 13 89.68 20 15.23 490 149 4.13 / 60.68 5 30
7 8 0.00 293 15.20 332 1479 5.61 / 62.16 5 143
Average= 5.18
(KJ/cycle)

Cycle 10 GMT 23/11/2022 21:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 15 15.22 472 108 0.11 / 51.08 5 6
2 3 1541.20 1 15.11 2533 38 0.15 / 51.12 5 18
3 7 2006.08 40 14.89 3085 1837 1.98 / 52.96 18 21
4 13 1906.24 20 14.88 2939 875 2.86 / 53.83 5 23
5 13 1289.08 20 14.94 2206 659 3.52 / 54.49 5 30
6 13 593.32 20 15.08 1261 380 3.90 / 54.87 5 37
7 13 87.72 20 15.23 491 150 4.05 / 55.02 5 31
8 13 12.20 20 15.25 370 113 4.16 / 55.13 5 26
9 8 -0.08 274 15.19 342 1423 5.58 / 56.56 5 137
Average= 5.14
(KJ/cycle)

Cycle 9 GMT 18/11/2022 19:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 16 15.20 472 115 0.11 / 45.57 5 6
2 3 1467.32 -1 15.54 0 0 0.00 / 45.57 5 6
3 7 2002.20 40 14.89 3078 1833 1.95 / 47.41 6 21
4 13 1934.96 20 14.88 2990 890 2.84 / 48.30 5 24
5 13 1158.16 20 14.97 2026 607 3.44 / 48.90 5 31
6 13 713.72 20 15.05 1426 429 3.87 / 49.33 5 36
7 13 63.60 20 15.24 455 139 4.01 / 49.47 5 29
8 8 0.08 293 15.20 337 1501 5.51 / 50.97 5 129
Average= 5.10
(KJ/cycle)

Cycle 8 GMT 13/11/2022 18:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 16 15.21 469 114 0.11 / 40.02 6 6
2 7 2007.68 41 14.89 3080 1880 1.99 / 41.90 6 21
3 13 1772.56 20 14.90 2818 840 2.83 / 42.74 5 25
4 13 1255.84 20 14.95 2163 647 3.48 / 43.39 5 31
5 13 588.96 20 15.09 1250 377 3.86 / 43.77 5 37
6 13 61.72 20 15.25 447 136 3.99 / 43.90 5 30
7 8 0.08 300 15.19 341 1554 5.55 / 45.46 5 163
Average= 5.05
(KJ/cycle)

Cycle 7 GMT 8/11/2022 16:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 16 15.22 472 115 0.11 / 34.40 6 6
2 3 1527.24 1 15.13 2511 38 0.15 / 34.44 5 7
3 7 2008.96 40 14.90 3074 1832 1.99 / 36.27 7 20
4 13 1943.68 20 14.88 3003 894 2.88 / 37.17 5 23
5 13 1251.84 20 14.95 2155 644 3.52 / 37.81 5 31
6 13 635.60 20 15.07 1318 397 3.92 / 38.21 5 37
7 13 132.40 20 15.22 561 171 4.09 / 38.38 5 35
8 8 -0.08 300 15.19 336 1531 5.62 / 39.91 5 144
Average= 4.99
(KJ/cycle)

Cycle 6 GMT 3/11/2022 14:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 16 15.23 440 107 0.11 / 28.95 6 6
2 7 2003.32 40 14.90 3083 1837 1.94 / 30.78 6 21
3 13 1834.52 20 14.90 2887 860 2.81 / 31.64 5 24
4 13 1248.72 20 14.95 2139 640 3.44 / 32.28 5 30
5 13 593.40 20 15.09 1252 378 3.82 / 32.66 5 37
6 13 98.40 20 15.24 507 155 3.98 / 32.82 5 29
7 8 0.04 295 15.21 328 1472 5.45 / 34.29 5 148
Average= 4.90
(KJ/cycle)

Cycle 5 GMT 29/10/2022 12:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 16 15.24 448 109 0.11 / 23.46 6 6
2 7 2004.80 40 14.89 3096 1844 1.95 / 25.31 5 20
3 13 1904.16 20 14.89 2974 886 2.84 / 26.19 5 23
4 13 1211.28 20 14.96 2093 626 3.47 / 26.82 5 30
5 13 765.32 20 15.05 1501 452 3.92 / 27.27 5 35
6 13 146.60 20 15.24 552 168 4.09 / 27.44 5 24
7 13 79.64 20 15.25 446 136 4.22 / 27.57 5 22
8 8 0.04 270 15.22 308 1266 5.49 / 28.84 5 142
Average= 4.81
(KJ/cycle)

Cycle 4 GMT 24/10/2022 11:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 15 15.23 451 103 0.10 / 17.88 6 6
2 7 2002.76 40 14.91 3075 1834 1.94 / 19.72 5 20
3 13 1904.40 20 14.89 2972 885 2.82 / 20.60 5 22
4 13 1366.20 20 14.93 2299 686 3.51 / 21.29 5 29
5 13 795.56 20 15.04 1535 462 3.97 / 21.75 5 34
6 13 151.40 20 15.25 561 171 4.14 / 21.92 5 22
7 13 84.52 20 15.25 451 138 4.28 / 22.06 5 21
8 8 0.12 272 15.22 312 1292 5.57 / 23.35 5 159
Average= 4.67
(KJ/cycle)

Cycle 3 GMT 19/10/2022 9:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 15 15.22 450 103 0.10 / 12.57 6 6
2 7 2002.80 40 14.91 3082 1838 1.94 / 14.41 6 20
3 13 1834.20 20 14.91 2874 857 2.80 / 15.27 5 23
4 13 1173.64 20 14.99 2019 605 3.40 / 15.88 5 30
5 13 630.96 20 15.10 1285 388 3.79 / 16.26 5 34
6 13 156.64 20 15.24 558 170 3.96 / 16.43 5 25
7 13 53.60 20 15.27 400 122 4.08 / 16.56 5 21
8 8 0.12 272 15.23 296 1226 5.31 / 17.78 5 177
Average= 4.45
(KJ/cycle)

Cycle 2 GMT 14/10/2022 7:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 12 15.20 446 81 0.08 / 7.03 6 6
2 10 1503.52 3 15.05 2483 112 0.19 / 7.14 5 15
3 3 1521.92 1 15.14 2512 38 0.23 / 7.18 5 5
4 7 2002.76 40 14.91 3079 1836 2.07 / 9.01 5 21
5 13 1866.76 20 14.92 2911 869 2.94 / 9.88 5 23
6 13 1248.96 20 14.96 2124 636 3.57 / 10.52 5 30
7 13 687.72 20 15.08 1369 413 3.98 / 10.93 5 35
8 13 108.84 20 15.25 495 151 4.14 / 11.08 5 24
9 13 46.88 20 15.26 391 119 4.26 / 11.20 5 22
10 8 -0.04 274 15.22 305 1272 5.53 / 12.47 5 136
Average= 4.16
(KJ/cycle)

Cycle 1 GMT 9/10/2022 6: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 18 15.41 397 110 0.11 / 1.72 6 6
2 3 1323.00 -3 15.59 0 0 0.00 / 1.72 6 6
3 7 1964.80 40 14.92 3007 1795 1.90 / 3.52 6 21
4 13 1831.08 20 14.90 2870 855 2.76 / 4.37 5 23
5 13 1234.24 20 14.95 2116 633 3.39 / 5.00 5 30
6 13 604.12 20 15.08 1244 375 3.77 / 5.38 5 36
7 13 99.16 20 15.22 487 148 3.92 / 5.53 5 30
8 13 34.52 20 15.23 382 116 4.03 / 5.64 5 26
9 8 0.16 278 15.19 308 1301 5.33 / 6.94 5 142
Average= 3.47
(KJ/cycle)

Cycle 0 GMT 4/10/2022 4:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 18 15.57 402 113 0.11 / 0.11 6 6
2 7 124.20 40 15.55 413 257 0.37 / 0.37 6 7
3 13 105.48 20 15.53 391 121 0.49 / 0.49 6 7
4 13 44.36 20 15.52 306 95 0.59 / 0.59 6 8
5 8 0.20 282 15.48 235 1026 1.61 / 1.61 6 137
Average= 1.61
(KJ/cycle)