SIO Argo Site:
Pump Diagnostics Page   



Serial= 7506 WMO= 4903057

Return

←PreviousNext→

Cycle 195 GMT 16/ 5/2024 9: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 30 14.82 452 201 0.20 / 1042.80 6 18
2 7 2012.72 40 14.59 3170 1850 2.05 / 1044.65 18 56
3 13 1986.12 20 14.54 3130 910 2.96 / 1045.56 6 57
4 13 1468.28 20 14.51 2458 713 3.67 / 1046.27 6 72
5 13 843.24 20 14.60 1586 463 4.14 / 1046.73 6 78
6 13 254.12 20 14.78 697 206 4.34 / 1046.94 6 76
7 8 0.16 267 14.81 292 1155 5.50 / 1048.10 6 133
Average= 14.97
(KJ/cycle)

Cycle 194 GMT 6/ 5/2024 12:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 30 14.83 449 200 0.20 / 1037.40 6 17
2 7 2004.04 40 14.59 3185 1859 2.06 / 1039.25 6 56
3 13 1977.48 20 14.54 3164 920 2.98 / 1040.17 6 59
4 13 1335.96 20 14.53 2297 668 3.65 / 1040.84 6 72
5 13 773.40 20 14.62 1510 442 4.09 / 1041.28 6 80
6 13 149.08 20 14.82 539 160 4.25 / 1041.44 6 72
7 8 0.24 265 14.81 294 1154 5.40 / 1042.60 6 134
Average= 15.11
(KJ/cycle)

Cycle 193 GMT 26/ 4/2024 15:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 30 14.83 447 199 0.20 / 1031.87 6 18
2 7 2015.56 40 14.59 3189 1861 2.06 / 1033.74 18 58
3 13 1989.20 20 14.53 3176 923 2.98 / 1034.66 6 61
4 13 1475.60 20 14.51 2475 718 3.70 / 1035.38 6 71
5 13 874.04 20 14.59 1644 480 4.18 / 1035.86 6 81
6 13 164.72 20 14.81 568 168 4.35 / 1036.03 6 75
7 8 0.12 268 14.81 295 1171 5.52 / 1037.20 6 141
Average= 15.25
(KJ/cycle)

Cycle 192 GMT 16/ 4/2024 18:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 30 14.80 464 206 0.21 / 1026.39 6 20
2 7 2004.60 40 14.59 3183 1858 2.06 / 1028.24 20 58
3 13 1975.08 20 14.54 3146 915 2.98 / 1029.16 6 61
4 13 1367.08 20 14.53 2336 679 3.66 / 1029.84 6 72
5 13 942.16 20 14.57 1738 506 4.16 / 1030.34 6 79
6 13 160.88 20 14.81 566 168 4.33 / 1030.51 6 74
7 8 0.20 263 14.80 299 1164 5.50 / 1031.68 6 130
Average= 15.40
(KJ/cycle)

Cycle 191 GMT 6/ 4/2024 22:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 30 14.82 463 206 0.21 / 1020.39 6 22
2 7 2013.68 40 14.59 3188 1861 2.07 / 1022.25 22 57
3 13 1984.08 20 14.54 3157 918 2.98 / 1023.16 6 59
4 13 1760.96 20 14.48 2867 830 3.81 / 1024.00 6 67
5 13 1157.36 20 14.51 2046 594 4.41 / 1024.59 6 76
6 13 725.48 20 14.59 1438 420 4.83 / 1025.01 6 83
7 8 0.08 266 14.79 298 1172 6.00 / 1026.18 6 132
Average= 15.55
(KJ/cycle)

Cycle 190 GMT 28/ 3/2024 1:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 30 14.82 464 206 0.21 / 1014.98 6 19
2 7 2011.80 40 14.59 3201 1868 2.07 / 1016.84 19 58
3 13 1983.28 20 14.54 3151 916 2.99 / 1017.76 6 60
4 13 1445.64 20 14.52 2436 707 3.70 / 1018.47 6 72
5 13 713.40 20 14.64 1420 416 4.11 / 1018.88 6 81
6 13 41.12 20 14.85 380 113 4.23 / 1019.00 6 67
7 8 0.04 264 14.81 303 1185 5.41 / 1020.18 6 132
Average= 15.70
(KJ/cycle)

Cycle 189 GMT 18/ 3/2024 4:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 30 14.80 447 198 0.20 / 1009.57 6 21
2 7 2013.44 40 14.60 3177 1855 2.05 / 1011.42 21 56
3 13 1985.16 20 14.54 3157 918 2.97 / 1012.34 6 60
4 13 1465.52 20 14.52 2459 714 3.69 / 1013.05 6 70
5 13 706.64 20 14.64 1413 414 4.10 / 1013.47 6 81
6 13 120.88 20 14.82 497 147 4.25 / 1013.62 6 72
7 8 -0.04 265 14.80 294 1153 5.40 / 1014.77 6 146
Average= 15.86
(KJ/cycle)

Cycle 188 GMT 8/ 3/2024 8:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 30 14.80 448 199 0.20 / 1003.94 6 19
2 7 2016.08 41 14.58 3193 1909 2.11 / 1005.85 6 56
3 13 1985.88 20 14.53 3156 917 3.02 / 1006.76 6 59
4 13 1415.48 20 14.52 2399 697 3.72 / 1007.46 6 71
5 13 884.84 20 14.58 1667 486 4.21 / 1007.95 6 79
6 13 329.04 20 14.73 836 246 4.45 / 1008.19 6 78
7 8 0.16 265 14.79 300 1176 5.63 / 1009.37 6 132
Average= 16.02
(KJ/cycle)

Cycle 187 GMT 27/ 2/2024 11:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 30 14.82 454 202 0.20 / 998.33 6 18
2 7 2005.40 40 14.60 3178 1856 2.06 / 1000.19 18 56
3 13 1980.16 20 14.54 3169 922 2.98 / 1001.11 6 59
4 13 1386.12 20 14.53 2353 684 3.66 / 1001.80 6 72
5 13 1043.48 20 14.54 1885 548 4.21 / 1002.34 6 76
6 13 302.04 20 14.74 783 231 4.44 / 1002.58 6 75
7 8 0.04 265 14.79 297 1164 5.61 / 1003.74 6 132
Average= 16.19
(KJ/cycle)

Cycle 186 GMT 17/ 2/2024 14:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 30 14.80 457 203 0.20 / 992.96 6 18
2 7 2017.52 40 14.60 3193 1865 2.07 / 994.82 18 56
3 13 1990.80 20 14.54 3147 915 2.98 / 995.74 6 58
4 13 1320.88 20 14.55 2261 658 3.64 / 996.40 6 71
5 13 737.80 20 14.63 1457 426 4.07 / 996.82 6 80
6 13 157.32 20 14.81 552 164 4.23 / 996.99 6 72
7 8 0.16 265 14.80 292 1145 5.38 / 998.13 6 131
Average= 16.36
(KJ/cycle)

Cycle 185 GMT 7/ 2/2024 18: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 30 14.81 456 203 0.20 / 987.42 6 17
2 7 2013.40 40 14.59 3188 1861 2.06 / 989.28 17 57
3 13 1986.08 20 14.55 3143 915 2.98 / 990.20 6 60
4 13 1332.68 20 14.54 2283 664 3.64 / 990.86 6 71
5 13 766.92 20 14.62 1505 440 4.08 / 991.30 6 81
6 13 424.04 20 14.70 972 286 4.37 / 991.59 6 80
7 8 0.16 267 14.79 296 1169 5.54 / 992.76 6 137
Average= 16.55
(KJ/cycle)

Cycle 184 GMT 28/ 1/2024 21:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 30 14.81 454 202 0.20 / 981.99 6 19
2 7 2010.76 41 14.59 3195 1911 2.11 / 983.90 19 57
3 13 1876.64 20 14.55 3026 881 2.99 / 984.78 6 60
4 13 1370.20 20 14.53 2348 682 3.68 / 985.47 6 73
5 13 786.04 20 14.60 1535 448 4.12 / 985.91 6 79
6 13 117.68 20 14.81 497 147 4.27 / 986.06 6 71
7 8 0.08 263 14.79 298 1159 5.43 / 987.22 6 132
Average= 16.73
(KJ/cycle)

Cycle 183 GMT 19/ 1/2024 0:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 30 14.81 454 202 0.20 / 976.67 6 18
2 7 2011.16 40 14.60 3192 1864 2.07 / 978.53 18 58
3 13 1800.72 20 14.55 2923 851 2.92 / 979.38 6 64
4 13 1310.24 20 14.54 2254 655 3.57 / 980.04 6 74
5 13 873.00 20 14.58 1644 479 4.05 / 980.52 6 79
6 13 30.52 20 14.84 346 103 4.15 / 980.62 6 64
7 8 0.04 263 14.79 301 1171 5.32 / 981.79 6 132
Average= 16.93
(KJ/cycle)

Cycle 182 GMT 9/ 1/2024 3:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 30 14.80 446 198 0.20 / 971.20 6 16
2 7 2012.68 40 14.60 3195 1866 2.06 / 973.06 16 57
3 13 1986.56 20 14.55 3151 917 2.98 / 973.98 6 59
4 13 1535.64 20 14.50 2570 745 3.73 / 974.72 6 70
5 13 618.36 20 14.65 1286 377 4.10 / 975.10 6 79
6 13 252.28 20 14.76 705 208 4.31 / 975.31 6 74
7 8 0.08 265 14.79 295 1156 5.47 / 976.47 6 138
Average= 17.13
(KJ/cycle)

Cycle 181 GMT 30/12/2023 7: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 30 14.81 440 195 0.20 / 965.75 6 14
2 7 2017.24 40 14.60 3198 1868 2.06 / 967.62 14 56
3 13 1990.96 20 14.54 3157 918 2.98 / 968.54 6 60
4 13 1295.88 20 14.55 2239 652 3.63 / 969.19 6 73
5 13 644.20 20 14.64 1321 387 4.02 / 969.57 6 81
6 13 332.68 20 14.72 835 246 4.27 / 969.82 6 76
7 8 0.08 265 14.78 301 1179 5.44 / 971.00 6 134
Average= 17.34
(KJ/cycle)

Cycle 180 GMT 20/12/2023 10:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 30 14.80 448 199 0.20 / 960.24 6 13
2 7 2005.28 40 14.60 3170 1851 2.05 / 962.09 13 55
3 13 1972.36 20 14.56 3120 909 2.96 / 963.00 6 59
4 13 1483.76 20 14.54 2474 719 3.68 / 963.72 6 68
5 13 1006.64 20 14.56 1827 532 4.21 / 964.25 6 76
6 13 147.00 20 14.79 546 162 4.37 / 964.41 6 70
7 8 0.32 265 14.79 292 1144 5.52 / 965.55 6 149
Average= 17.56
(KJ/cycle)

Cycle 179 GMT 10/12/2023 13:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 30 14.81 435 193 0.19 / 954.79 6 17
2 7 2014.08 40 14.60 3197 1867 2.06 / 956.66 17 56
3 13 1985.52 20 14.54 3166 921 2.98 / 957.58 6 59
4 13 1489.20 20 14.52 2500 726 3.71 / 958.30 6 69
5 13 811.96 20 14.60 1566 457 4.16 / 958.76 6 78
6 13 70.32 20 14.82 417 124 4.29 / 958.88 6 67
7 8 0.16 265 14.78 295 1155 5.44 / 960.04 6 130
Average= 17.78
(KJ/cycle)

Cycle 178 GMT 30/11/2023 16:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 30 14.80 453 201 0.20 / 949.18 6 15
2 7 2011.24 41 14.61 3181 1905 2.11 / 951.09 15 56
3 13 1981.76 20 14.55 3139 913 3.02 / 952.00 6 59
4 13 1680.76 20 14.50 2758 800 3.82 / 952.80 6 67
5 13 952.44 20 14.55 1755 511 4.33 / 953.31 6 78
6 13 75.56 20 14.81 424 126 4.46 / 953.44 6 67
7 8 0.20 265 14.78 296 1159 5.62 / 954.59 6 133
Average= 18.01
(KJ/cycle)

Cycle 177 GMT 20/11/2023 19:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 30 14.80 453 201 0.20 / 943.71 6 12
2 7 2011.96 40 14.61 3190 1864 2.07 / 945.58 12 56
3 13 1981.32 20 14.56 3154 918 2.98 / 946.49 6 59
4 13 1353.36 20 14.54 2316 673 3.66 / 947.17 6 71
5 13 802.48 20 14.59 1563 456 4.11 / 947.62 6 79
6 13 176.44 20 14.77 597 176 4.29 / 947.80 6 69
7 8 0.08 267 14.77 299 1179 5.47 / 948.98 6 131
Average= 18.25
(KJ/cycle)

Cycle 176 GMT 10/11/2023 23: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 30 14.80 453 201 0.20 / 938.28 6 14
2 7 2010.68 40 14.61 3186 1862 2.06 / 940.14 14 57
3 13 1979.16 20 14.56 3158 920 2.98 / 941.06 6 60
4 13 1382.64 20 14.55 2344 682 3.66 / 941.74 6 71
5 13 744.08 20 14.62 1465 428 4.09 / 942.17 6 81
6 13 121.80 20 14.79 512 151 4.24 / 942.32 6 70
7 8 0.20 267 14.78 302 1192 5.44 / 943.51 6 133
Average= 18.50
(KJ/cycle)

Cycle 175 GMT 1/11/2023 2:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 30 14.80 449 199 0.20 / 932.60 6 11
2 7 2012.52 40 14.61 3175 1855 2.05 / 934.46 11 56
3 13 1981.40 20 14.56 3150 917 2.97 / 935.38 6 58
4 13 1762.12 20 14.50 2851 827 3.80 / 936.20 6 66
5 13 926.84 20 14.57 1716 500 4.30 / 936.70 6 76
6 13 269.92 20 14.74 731 215 4.51 / 936.92 6 75
7 8 0.20 267 14.78 293 1156 5.67 / 938.07 6 132
Average= 18.76
(KJ/cycle)

Cycle 174 GMT 22/10/2023 5:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 30 14.81 437 194 0.19 / 927.14 6 14
2 7 2012.96 41 14.60 3194 1912 2.11 / 929.05 14 57
3 13 1984.72 20 14.55 3161 920 3.03 / 929.97 6 60
4 13 1393.88 20 14.53 2367 688 3.71 / 930.66 6 72
5 13 784.76 20 14.59 1524 445 4.16 / 931.11 6 79
6 13 94.20 20 14.80 458 136 4.29 / 931.24 6 65
7 8 0.20 268 14.78 293 1161 5.45 / 932.40 6 141
Average= 19.03
(KJ/cycle)

Cycle 173 GMT 12/10/2023 8:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 30 14.79 459 204 0.20 / 921.85 6 12
2 7 2014.08 40 14.61 3175 1855 2.06 / 923.71 12 57
3 13 1987.28 20 14.56 3155 919 2.98 / 924.63 6 58
4 13 1261.48 20 14.56 2191 638 3.62 / 925.27 6 74
5 13 665.84 20 14.64 1354 396 4.01 / 925.66 6 80
6 13 60.28 20 14.82 403 119 4.13 / 925.78 6 66
7 8 0.16 265 14.78 298 1167 5.30 / 926.95 6 133
Average= 19.31
(KJ/cycle)

Cycle 172 GMT 2/10/2023 11:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 30 14.80 457 203 0.20 / 916.39 6 15
2 7 2004.36 40 14.61 3181 1859 2.06 / 918.25 15 56
3 13 1975.00 20 14.57 3127 911 2.97 / 919.16 6 59
4 13 1440.44 20 14.54 2425 705 3.68 / 919.87 6 71
5 13 713.60 20 14.63 1416 414 4.09 / 920.28 6 79
6 13 204.20 20 14.76 640 189 4.28 / 920.47 6 71
7 13 15.00 20 14.81 323 96 4.38 / 920.56 6 68
8 8 0.12 246 14.76 299 1086 5.46 / 921.65 6 137
Average= 19.61
(KJ/cycle)

Cycle 171 GMT 22/ 9/2023 14:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 30 14.79 451 200 0.20 / 910.91 6 12
2 7 2014.48 40 14.61 3192 1865 2.07 / 912.77 12 58
3 13 1987.60 20 14.56 3170 923 2.99 / 913.70 6 61
4 13 1536.48 20 14.52 2558 743 3.73 / 914.44 6 71
5 13 785.00 20 14.60 1529 446 4.18 / 914.89 6 81
6 13 126.56 20 14.79 506 150 4.33 / 915.04 6 71
7 8 0.24 265 14.78 294 1152 5.48 / 916.19 6 129
Average= 19.92
(KJ/cycle)

Cycle 170 GMT 12/ 9/2023 18:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 30 14.79 448 199 0.20 / 905.45 6 15
2 7 2004.40 40 14.61 3189 1864 2.06 / 907.31 15 58
3 13 1972.32 20 14.56 3135 913 2.98 / 908.22 6 60
4 13 1313.00 20 14.56 2259 658 3.63 / 908.88 6 74
5 13 805.08 20 14.60 1553 453 4.09 / 909.33 6 82
6 13 248.28 20 14.75 700 206 4.29 / 909.54 6 76
7 8 0.16 267 14.77 296 1167 5.46 / 910.71 6 132
Average= 20.24
(KJ/cycle)

Cycle 169 GMT 2/ 9/2023 21:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 30 14.80 461 205 0.20 / 900.03 6 14
2 10 1002.80 3 14.97 1858 83 0.29 / 900.12 6 56
3 3 911.08 -1 15.28 10 0 0.08 / 900.12 6 56
4 7 2004.44 40 14.61 3186 1862 2.15 / 901.98 56 57
5 13 1832.12 20 14.56 2975 866 3.02 / 902.85 6 64
6 13 1429.20 20 14.54 2416 703 3.72 / 903.55 6 73
7 13 631.24 20 14.64 1308 383 4.10 / 903.93 6 82
8 13 120.80 20 14.78 496 147 4.25 / 904.08 6 71
9 8 0.08 265 14.76 299 1170 5.42 / 905.25 6 136
Average= 20.57
(KJ/cycle)

Cycle 168 GMT 24/ 8/2023 0:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 30 14.78 444 197 0.20 / 894.47 6 16
2 7 2018.32 41 14.61 3210 1923 2.12 / 896.39 16 57
3 13 1993.72 20 14.55 3168 922 3.04 / 897.31 6 60
4 13 1477.08 20 14.53 2485 722 3.76 / 898.03 6 71
5 13 905.36 20 14.58 1689 493 4.26 / 898.53 6 78
6 13 65.88 20 14.82 423 125 4.38 / 898.65 6 67
7 8 0.16 261 14.78 305 1177 5.56 / 899.83 6 135
Average= 20.93
(KJ/cycle)

Cycle 167 GMT 14/ 8/2023 3:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 30 14.80 439 195 0.19 / 888.95 6 16
2 7 2015.80 40 14.60 3193 1865 2.06 / 890.81 16 57
3 13 1987.60 20 14.55 3162 920 2.98 / 891.73 6 61
4 13 1473.12 20 14.53 2475 719 3.70 / 892.45 6 72
5 13 820.52 20 14.59 1573 459 4.16 / 892.91 6 79
6 13 220.48 20 14.75 656 194 4.35 / 893.10 6 74
7 8 0.04 270 14.76 293 1168 5.52 / 894.27 6 140
Average= 21.29
(KJ/cycle)

Cycle 166 GMT 4/ 8/2023 6:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 30 14.79 452 201 0.20 / 883.40 6 15
2 7 2002.92 40 14.61 3199 1869 2.07 / 885.27 15 58
3 13 1971.20 20 14.57 3140 915 2.99 / 886.19 6 62
4 13 1640.52 20 14.52 2707 786 3.77 / 886.97 6 68
5 13 767.76 20 14.61 1503 439 4.21 / 887.41 6 80
6 13 117.96 20 14.79 497 147 4.36 / 887.56 6 67
7 8 0.04 270 14.78 299 1193 5.55 / 888.75 6 141
Average= 21.68
(KJ/cycle)

Cycle 165 GMT 25/ 7/2023 10: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 30 14.79 438 194 0.19 / 878.05 6 14
2 7 2004.60 40 14.63 3167 1853 2.05 / 879.90 14 56
3 13 1973.16 20 14.57 3149 918 2.97 / 880.82 6 60
4 13 1234.72 20 14.58 2145 625 3.59 / 881.45 6 73
5 13 735.68 20 14.62 1459 427 4.02 / 881.87 6 79
6 13 179.28 20 14.76 592 175 4.19 / 882.05 6 71
7 8 0.16 265 14.77 295 1155 5.35 / 883.20 6 131
Average= 22.08
(KJ/cycle)

Cycle 164 GMT 15/ 7/2023 13:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 30 14.79 456 202 0.20 / 872.65 6 14
2 7 2015.28 40 14.61 3199 1869 2.07 / 874.52 14 57
3 13 1988.16 20 14.57 3157 920 2.99 / 875.44 6 61
4 13 1310.80 20 14.56 2247 654 3.65 / 876.09 6 74
5 13 760.08 20 14.62 1491 436 4.08 / 876.53 6 80
6 13 119.88 20 14.79 503 149 4.23 / 876.68 6 70
7 8 0.08 267 14.77 299 1179 5.41 / 877.85 6 140
Average= 22.51
(KJ/cycle)

Cycle 163 GMT 5/ 7/2023 16:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 30 14.80 446 198 0.20 / 867.24 6 13
2 7 2005.32 41 14.62 3188 1911 2.11 / 869.15 13 57
3 13 1973.12 20 14.57 3142 916 3.02 / 870.06 6 60
4 13 1252.32 20 14.58 2170 633 3.66 / 870.69 6 72
5 13 808.04 20 14.61 1562 456 4.11 / 871.15 6 80
6 13 97.36 20 14.80 467 138 4.25 / 871.29 6 69
7 8 0.16 265 14.78 295 1155 5.41 / 872.44 6 134
Average= 22.96
(KJ/cycle)

Cycle 162 GMT 25/ 6/2023 19:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 30 14.78 454 201 0.20 / 861.62 6 15
2 7 2013.60 40 14.63 3202 1874 2.08 / 863.49 15 57
3 13 1986.20 20 14.58 3151 919 2.99 / 864.41 6 59
4 13 1693.88 20 14.52 2791 811 3.80 / 865.22 6 67
5 13 887.36 20 14.59 1662 485 4.29 / 865.71 6 80
6 13 115.88 20 14.80 492 146 4.44 / 865.85 6 70
7 8 0.16 267 14.78 300 1184 5.62 / 867.04 6 139
Average= 23.43
(KJ/cycle)

Cycle 161 GMT 15/ 6/2023 23:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 30 14.77 462 205 0.20 / 855.89 6 16
2 7 2011.76 40 14.62 3200 1871 2.08 / 857.76 16 56
3 13 1981.76 20 14.58 3150 919 2.99 / 858.68 6 61
4 13 1226.40 20 14.58 2137 623 3.62 / 859.30 6 73
5 13 999.08 20 14.57 1819 530 4.15 / 859.83 6 78
6 13 611.00 20 14.62 1273 372 4.52 / 860.21 6 82
7 8 0.16 270 14.76 304 1212 5.73 / 861.42 6 140
Average= 23.93
(KJ/cycle)

Cycle 160 GMT 6/ 6/2023 2:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 30 14.77 458 203 0.20 / 850.10 6 18
2 7 2005.08 40 14.62 3169 1853 2.06 / 851.95 18 56
3 13 1975.36 20 14.57 3146 917 2.97 / 852.87 6 60
4 13 1552.88 20 14.54 2590 753 3.73 / 853.62 6 71
5 13 1012.76 20 14.57 1828 533 4.26 / 854.16 6 78
6 13 510.08 20 14.66 1102 323 4.58 / 854.48 6 82
7 8 0.00 272 14.76 301 1208 5.79 / 855.69 6 138
Average= 24.45
(KJ/cycle)

Cycle 159 GMT 27/ 5/2023 6: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 30 14.78 460 204 0.20 / 844.48 6 18
2 7 2013.60 40 14.62 3209 1877 2.08 / 846.35 18 58
3 13 1984.04 20 14.57 3140 915 3.00 / 847.27 6 60
4 13 1178.64 20 14.59 2069 604 3.60 / 847.87 6 76
5 13 1111.52 20 14.55 1969 573 4.17 / 848.44 6 77
6 13 421.36 20 14.69 974 286 4.46 / 848.73 6 81
7 8 0.08 267 14.76 296 1167 5.62 / 849.90 6 134
Average= 25.00
(KJ/cycle)

Cycle 158 GMT 17/ 5/2023 9:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 30 14.78 459 204 0.20 / 838.80 6 19
2 7 2003.08 40 14.63 3165 1852 2.06 / 840.65 19 57
3 13 1971.80 20 14.58 3132 913 2.97 / 841.56 6 61
4 13 1591.48 20 14.54 2630 765 3.73 / 842.33 6 70
5 13 977.32 20 14.58 1784 520 4.25 / 842.85 6 79
6 13 347.16 20 14.71 861 253 4.51 / 843.10 6 77
7 8 0.08 268 14.76 296 1171 5.68 / 844.27 6 138
Average= 25.58
(KJ/cycle)

Cycle 157 GMT 7/ 5/2023 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 30 14.78 457 203 0.20 / 833.22 6 18
2 10 1003.04 3 14.97 1825 82 0.28 / 833.30 6 52
3 3 937.40 -1 15.28 10 0 0.08 / 833.30 6 52
4 7 2013.60 40 14.62 3189 1865 2.15 / 835.16 52 57
5 13 1985.72 20 14.57 3141 915 3.06 / 836.08 6 60
6 13 1495.76 20 14.55 2502 728 3.79 / 836.81 6 71
7 13 692.48 20 14.64 1391 407 4.20 / 837.21 6 80
8 13 234.92 20 14.75 686 202 4.40 / 837.42 6 73
9 8 0.28 270 14.77 295 1176 5.58 / 838.59 6 143
Average= 26.21
(KJ/cycle)

Cycle 156 GMT 27/ 4/2023 15:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 30 14.79 465 206 0.21 / 827.67 6 17
2 10 1000.60 3 14.96 1847 83 0.29 / 827.75 6 55
3 3 893.40 -2 15.28 10 0 0.08 / 827.75 6 55
4 7 2011.64 40 14.62 3207 1875 2.16 / 829.63 55 58
5 13 1979.84 20 14.57 3140 915 3.08 / 830.54 6 60
6 13 1636.12 20 14.53 2695 783 3.86 / 831.32 6 69
7 13 640.24 20 14.64 1315 385 4.25 / 831.71 6 79
8 13 49.08 20 14.81 387 115 4.36 / 831.82 6 66
9 8 0.12 265 14.77 304 1190 5.55 / 833.01 6 130
Average= 26.87
(KJ/cycle)

Cycle 155 GMT 17/ 4/2023 19: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 30 14.80 452 201 0.20 / 822.39 6 21
2 7 2011.28 41 14.63 3188 1912 2.11 / 824.30 21 57
3 13 1978.32 20 14.59 3135 915 3.03 / 825.21 6 60
4 13 1309.64 20 14.58 2242 654 3.68 / 825.87 6 73
5 13 545.12 20 14.68 1160 341 4.02 / 826.21 6 78
6 8 0.04 283 14.78 300 1255 5.28 / 827.46 6 129
Average= 27.58
(KJ/cycle)

Cycle 154 GMT 7/ 4/2023 22: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 30 14.77 451 200 0.20 / 816.93 6 19
2 7 2014.36 41 14.62 3207 1922 2.12 / 818.85 19 57
3 13 1987.56 20 14.58 3165 923 3.05 / 819.77 6 61
4 13 1540.32 20 14.55 2557 744 3.79 / 820.52 6 71
5 13 672.08 20 14.65 1358 398 4.19 / 820.91 6 80
6 13 65.28 20 14.82 397 118 4.30 / 821.03 6 63
7 8 0.00 267 14.79 292 1153 5.46 / 822.19 6 134
Average= 28.35
(KJ/cycle)

Cycle 153 GMT 29/ 3/2023 1:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 30 14.80 453 201 0.20 / 811.32 6 18
2 7 2005.32 40 14.64 3176 1860 2.06 / 813.18 18 57
3 13 1977.92 20 14.59 3145 918 2.98 / 814.10 6 59
4 13 1603.84 20 14.56 2646 771 3.75 / 814.87 6 69
5 13 963.88 20 14.59 1768 516 4.27 / 815.38 6 77
6 13 157.56 20 14.78 552 163 4.43 / 815.55 6 67
7 8 0.08 272 14.77 294 1181 5.61 / 816.73 6 146
Average= 29.17
(KJ/cycle)

Cycle 152 GMT 19/ 3/2023 4:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 30 14.78 463 205 0.21 / 805.94 6 20
2 7 2005.84 40 14.64 3173 1858 2.06 / 807.80 20 56
3 13 1977.12 20 14.60 3148 919 2.98 / 808.71 6 60
4 13 1537.28 20 14.56 2542 740 3.72 / 809.45 6 69
5 13 629.08 20 14.67 1286 377 4.10 / 809.83 6 79
6 13 62.68 20 14.82 394 117 4.22 / 809.95 6 65
7 8 0.08 267 14.79 296 1169 5.39 / 811.12 6 134
Average= 30.04
(KJ/cycle)

Cycle 151 GMT 9/ 3/2023 8: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 30 14.79 456 202 0.20 / 800.39 6 21
2 7 2013.52 40 14.64 3195 1871 2.07 / 802.26 21 58
3 13 1982.12 20 14.58 3156 920 2.99 / 803.18 6 60
4 13 1712.96 20 14.53 2787 810 3.80 / 803.99 6 68
5 13 754.48 20 14.63 1474 431 4.23 / 804.42 6 81
6 13 129.76 20 14.79 503 149 4.38 / 804.57 6 67
7 8 0.12 267 14.78 294 1160 5.54 / 805.73 6 133
Average= 30.99
(KJ/cycle)

Cycle 150 GMT 27/ 2/2023 11:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 30 14.77 453 201 0.20 / 795.03 6 19
2 7 2006.72 40 14.64 3185 1865 2.07 / 796.90 19 56
3 13 1983.32 20 14.58 3166 923 2.99 / 797.82 6 59
4 13 1462.44 20 14.57 2440 711 3.70 / 798.53 6 70
5 13 570.76 20 14.69 1199 352 4.05 / 798.89 6 79
6 13 100.04 20 14.81 464 137 4.19 / 799.02 6 65
7 8 0.12 267 14.79 295 1165 5.35 / 800.19 6 139
Average= 32.01
(KJ/cycle)

Cycle 149 GMT 17/ 2/2023 14:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 30 14.80 464 206 0.21 / 789.35 6 18
2 7 2011.60 40 14.64 3186 1866 2.07 / 791.21 18 57
3 13 1983.00 20 14.59 3146 918 2.99 / 792.13 6 59
4 13 1429.08 20 14.56 2404 700 3.69 / 792.83 6 71
5 13 1074.52 20 14.57 1929 562 4.25 / 793.39 6 77
6 13 289.28 20 14.74 767 226 4.48 / 793.62 6 73
7 8 0.12 272 14.77 302 1213 5.69 / 794.83 6 134
Average= 33.12
(KJ/cycle)

Cycle 148 GMT 7/ 2/2023 18: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 30 14.76 469 208 0.21 / 784.06 6 21
2 7 2011.04 41 14.64 3189 1914 2.12 / 785.97 21 56
3 13 1763.40 20 14.61 2858 835 2.96 / 786.80 6 64
4 13 1402.88 20 14.58 2376 693 3.65 / 787.50 6 72
5 13 660.72 20 14.66 1338 392 4.04 / 787.89 6 80
6 8 0.16 285 14.80 297 1253 5.29 / 789.14 6 130
Average= 34.31
(KJ/cycle)

Cycle 147 GMT 28/ 1/2023 21: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 30 14.79 451 200 0.20 / 778.41 6 17
2 7 2016.32 40 14.65 3179 1863 2.06 / 780.27 17 56
3 13 1989.20 20 14.60 3158 922 2.99 / 781.19 6 59
4 13 1303.60 20 14.59 2239 653 3.64 / 781.84 6 71
5 13 686.16 20 14.65 1387 406 4.04 / 782.25 6 79
6 13 621.36 20 14.64 1284 376 4.42 / 782.63 6 80
7 8 0.08 274 14.76 302 1221 5.64 / 783.85 6 137
Average= 35.63
(KJ/cycle)

Cycle 146 GMT 19/ 1/2023 0:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 30 14.79 460 204 0.20 / 772.73 6 17
2 7 2010.12 40 14.63 3200 1873 2.08 / 774.60 9 58
3 13 1945.16 20 14.59 3117 910 2.99 / 775.51 6 62
4 13 1807.84 20 14.53 2930 851 3.84 / 776.37 6 66
5 13 842.08 20 14.62 1606 470 4.31 / 776.84 6 80
6 13 164.40 20 14.79 567 168 4.48 / 777.00 6 70
7 8 0.24 272 14.78 299 1202 5.68 / 778.21 6 133
Average= 37.06
(KJ/cycle)

Cycle 145 GMT 9/ 1/2023 3:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 30 14.78 445 197 0.20 / 767.42 6 17
2 7 2003.96 40 14.66 3176 1862 2.06 / 769.28 17 57
3 13 1972.52 20 14.60 3127 913 2.97 / 770.19 6 58
4 13 1322.56 20 14.60 2261 660 3.63 / 770.86 6 71
5 13 569.52 20 14.69 1202 353 3.99 / 771.21 6 79
6 13 129.08 20 14.81 513 152 4.14 / 771.36 6 69
7 8 0.16 265 14.79 298 1168 5.31 / 772.53 6 131
Average= 38.63
(KJ/cycle)

Cycle 144 GMT 30/12/2022 6:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 30 14.80 440 195 0.20 / 761.93 6 16
2 7 2015.00 40 14.64 3192 1869 2.06 / 763.80 16 56
3 13 1988.76 20 14.59 3173 926 2.99 / 764.73 6 60
4 13 1438.96 20 14.57 2424 706 3.70 / 765.43 6 71
5 13 886.40 20 14.60 1658 484 4.18 / 765.92 6 80
6 13 71.44 20 14.81 420 124 4.31 / 766.04 6 69
7 8 0.04 270 14.78 296 1181 5.49 / 767.22 6 138
Average= 40.38
(KJ/cycle)

Cycle 143 GMT 20/12/2022 9:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 30 14.79 452 201 0.20 / 756.49 6 16
2 7 2013.36 40 14.64 3190 1868 2.07 / 758.36 16 58
3 13 1981.84 20 14.60 3137 916 2.98 / 759.28 6 60
4 13 1557.76 20 14.56 2590 754 3.74 / 760.03 6 71
5 13 606.56 20 14.68 1258 369 4.11 / 760.40 6 80
6 13 114.76 20 14.81 492 146 4.25 / 760.55 6 68
7 8 0.16 270 14.79 298 1190 5.44 / 761.74 6 144
Average= 42.32
(KJ/cycle)

Cycle 142 GMT 10/12/2022 12:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 30 14.80 448 199 0.20 / 751.03 6 15
2 7 2004.84 40 14.65 3184 1866 2.06 / 752.89 15 58
3 13 1974.12 20 14.59 3150 919 2.98 / 753.81 6 60
4 13 1391.72 20 14.58 2363 689 3.67 / 754.50 6 72
5 13 714.64 20 14.65 1433 420 4.09 / 754.92 6 81
6 13 170.44 20 14.78 590 174 4.27 / 755.09 6 72
7 8 0.16 270 14.78 300 1197 5.46 / 756.29 6 133
Average= 44.49
(KJ/cycle)

Cycle 141 GMT 30/11/2022 16: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 30 14.80 463 206 0.21 / 745.60 6 14
2 7 2004.68 40 14.64 3186 1866 2.07 / 747.47 14 57
3 13 1975.60 20 14.60 3142 917 2.99 / 748.39 6 61
4 13 1387.92 20 14.58 2368 691 3.68 / 749.08 6 72
5 13 813.60 20 14.63 1565 458 4.14 / 749.54 6 78
6 13 69.16 20 14.83 409 121 4.26 / 749.66 6 64
7 8 0.04 270 14.79 293 1170 5.43 / 750.83 6 131
Average= 46.93
(KJ/cycle)

Cycle 140 GMT 20/11/2022 19:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 30 14.77 446 198 0.20 / 740.05 6 14
2 7 2014.92 40 14.64 3205 1877 2.07 / 741.92 14 58
3 13 1983.04 20 14.59 3158 922 3.00 / 742.85 6 60
4 13 1442.56 20 14.58 2432 709 3.71 / 743.56 6 72
5 13 914.92 20 14.61 1704 498 4.20 / 744.05 6 78
6 13 136.20 20 14.80 529 157 4.36 / 744.21 6 71
7 8 0.08 267 14.79 301 1189 5.55 / 745.40 6 137
Average= 49.69
(KJ/cycle)

Cycle 139 GMT 10/11/2022 22:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 30 14.80 463 206 0.21 / 734.52 6 15
2 7 2005.68 40 14.64 3193 1870 2.08 / 736.39 15 57
3 13 1973.68 20 14.60 3149 920 2.99 / 737.31 6 60
4 13 1449.08 20 14.58 2436 710 3.71 / 738.02 6 71
5 13 809.40 20 14.63 1565 458 4.16 / 738.48 6 80
6 13 165.88 20 14.78 578 171 4.33 / 738.65 6 72
7 8 0.20 270 14.77 302 1204 5.54 / 739.85 6 136
Average= 52.85
(KJ/cycle)

Cycle 138 GMT 1/11/2022 2: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 30 14.77 459 203 0.20 / 729.09 6 16
2 7 2006.32 41 14.65 3186 1914 2.12 / 731.01 16 57
3 13 1976.32 20 14.60 3151 920 3.04 / 731.93 6 60
4 13 1281.72 20 14.60 2210 645 3.68 / 732.57 6 73
5 13 690.64 20 14.66 1390 408 4.09 / 732.98 6 82
6 13 63.36 20 14.83 414 123 4.21 / 733.10 6 68
7 8 0.12 267 14.79 306 1208 5.42 / 734.31 6 133
Average= 56.49
(KJ/cycle)

Cycle 137 GMT 22/10/2022 4:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 30 14.79 449 199 0.20 / 723.38 6 14
2 7 2014.56 40 14.65 3186 1867 2.07 / 725.25 14 57
3 13 1988.88 20 14.59 3163 923 2.99 / 726.17 6 61
4 13 1334.00 20 14.59 2296 670 3.66 / 726.84 6 74
5 13 827.72 20 14.63 1590 465 4.12 / 727.31 6 80
6 13 479.08 20 14.69 1080 317 4.44 / 727.62 6 80
7 13 31.24 20 14.80 376 111 4.55 / 727.73 6 70
8 8 0.08 248 14.76 316 1157 5.71 / 728.89 6 137
Average= 60.74
(KJ/cycle)

Cycle 136 GMT 12/10/2022 8: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 30 14.79 459 204 0.20 / 717.88 6 13
2 7 2013.16 41 14.64 3196 1918 2.12 / 719.80 13 58
3 13 1982.08 20 14.59 3145 918 3.04 / 720.72 6 62
4 13 1414.12 20 14.59 2390 697 3.74 / 721.41 6 72
5 13 799.44 20 14.64 1544 452 4.19 / 721.87 6 80
6 13 83.36 20 14.82 439 130 4.32 / 722.00 6 66
7 8 0.12 270 14.78 297 1185 5.50 / 723.18 6 133
Average= 65.74
(KJ/cycle)

Cycle 135 GMT 2/10/2022 11:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 30 14.78 464 206 0.21 / 712.29 6 13
2 7 2005.00 40 14.65 3180 1863 2.07 / 714.15 13 57
3 13 1973.88 20 14.60 3132 915 2.98 / 715.07 6 62
4 13 1538.40 20 14.58 2562 747 3.73 / 715.82 6 70
5 13 839.48 20 14.64 1595 467 4.20 / 716.28 6 78
6 13 261.72 20 14.77 718 212 4.41 / 716.50 6 76
7 8 0.00 270 14.78 296 1181 5.59 / 717.68 6 135
Average= 71.77
(KJ/cycle)

Cycle 134 GMT 22/ 9/2022 14:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 30 14.80 445 198 0.20 / 706.58 6 13
2 7 2011.12 40 14.65 3185 1866 2.06 / 708.45 13 59
3 13 1981.52 20 14.61 3145 919 2.98 / 709.37 6 63
4 13 1646.12 20 14.56 2696 785 3.77 / 710.15 6 71
5 13 897.20 20 14.63 1661 486 4.25 / 710.64 6 79
6 13 286.44 20 14.76 765 226 4.48 / 710.87 6 77
7 8 0.12 276 14.78 299 1220 5.70 / 712.09 6 129
Average= 79.12
(KJ/cycle)

Cycle 133 GMT 12/ 9/2022 18: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 30 14.78 461 204 0.20 / 701.14 6 14
2 7 2012.36 40 14.65 3180 1863 2.07 / 703.01 14 59
3 13 1812.76 20 14.62 2912 851 2.92 / 703.86 6 67
4 13 1546.00 20 14.58 2560 746 3.67 / 704.60 6 73
5 13 827.76 20 14.64 1554 455 4.12 / 705.06 6 82
6 13 97.60 20 14.82 458 136 4.26 / 705.19 6 70
7 8 0.20 276 14.79 292 1192 5.45 / 706.39 6 137
Average= 88.30
(KJ/cycle)

Cycle 132 GMT 2/ 9/2022 21:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 30 14.80 447 198 0.20 / 695.41 6 14
2 7 2013.24 40 14.66 3169 1858 2.06 / 697.27 14 59
3 13 1983.36 20 14.62 3127 914 2.97 / 698.19 6 60
4 13 1578.80 20 14.58 2593 756 3.73 / 698.94 6 70
5 13 805.12 20 14.66 1524 447 4.17 / 699.39 6 79
6 13 519.80 20 14.70 1109 326 4.50 / 699.72 6 81
7 8 0.08 281 14.79 294 1222 5.72 / 700.94 6 136
Average= 100.13
(KJ/cycle)

Cycle 131 GMT 24/ 8/2022 0:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 30 14.79 433 192 0.19 / 689.97 6 15
2 7 2006.32 41 14.66 3166 1903 2.10 / 691.87 15 59
3 13 1977.16 20 14.61 3121 912 3.01 / 692.78 6 63
4 13 1429.36 20 14.60 2397 700 3.71 / 693.48 6 75
5 13 601.40 20 14.70 1230 362 4.07 / 693.84 6 82
6 13 285.56 20 14.77 743 219 4.29 / 694.06 6 78
7 8 0.08 274 14.80 284 1152 5.44 / 695.22 6 131
Average= 115.87
(KJ/cycle)

Cycle 130 GMT 14/ 8/2022 4: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.28 30 14.78 453 201 0.20 / 684.61 6 15
2 7 2013.32 40 14.66 3176 1862 2.06 / 686.47 15 59
3 13 1754.36 20 14.63 2833 829 2.89 / 687.30 6 68
4 13 1320.00 20 14.61 2236 653 3.55 / 687.95 6 76
5 13 991.96 20 14.61 1777 519 4.06 / 688.47 6 79
6 13 112.72 20 14.82 473 140 4.20 / 688.61 6 72
7 8 0.04 276 14.79 285 1163 5.37 / 689.78 6 135
Average= 137.96
(KJ/cycle)

Cycle 129 GMT 4/ 8/2022 7:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 30 14.79 455 202 0.20 / 679.18 6 15
2 7 2006.04 40 14.67 3145 1845 2.05 / 681.03 15 57
3 13 1977.80 20 14.62 3124 913 2.96 / 681.94 6 61
4 13 1274.68 20 14.62 2180 637 3.60 / 682.58 6 75
5 13 751.56 20 14.67 1454 427 4.02 / 683.01 6 81
6 13 305.40 20 14.76 779 230 4.25 / 683.24 6 78
7 8 0.12 276 14.79 287 1172 5.43 / 684.41 6 134
Average= 171.10
(KJ/cycle)

Cycle 128 GMT 25/ 7/2022 10:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 30 14.79 474 210 0.21 / 673.71 6 16
2 7 2009.36 41 14.66 3167 1904 2.11 / 675.61 6 58
3 13 1871.60 20 14.63 2996 877 2.99 / 676.49 6 64
4 13 1428.04 20 14.60 2390 698 3.69 / 677.19 6 72
5 13 980.12 20 14.62 1753 513 4.20 / 677.70 6 79
6 13 58.40 20 14.83 391 116 4.32 / 677.81 6 67
7 8 0.12 274 14.79 288 1167 5.48 / 678.98 6 129
Average= 226.33
(KJ/cycle)

Cycle 127 GMT 15/ 7/2022 14: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 30 14.81 456 203 0.20 / 668.21 6 15
2 10 1004.52 4 14.99 1846 111 0.31 / 668.32 6 48
3 3 892.16 -2 15.31 10 0 0.11 / 668.32 6 48
4 7 2005.52 40 14.67 3143 1844 2.16 / 670.16 48 56
5 13 1973.76 20 14.62 3109 909 3.07 / 671.07 6 61
6 13 1448.00 20 14.60 2419 706 3.77 / 671.78 6 72
7 13 684.48 20 14.68 1360 399 4.17 / 672.18 6 79
8 13 30.96 20 14.84 358 106 4.28 / 672.28 6 63
9 8 0.08 276 14.80 297 1213 5.49 / 673.50 6 151
Average= 336.75
(KJ/cycle)

Cycle 126 GMT 5/ 7/2022 17:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 30 14.78 461 204 0.20 / 662.77 6 14
2 10 1001.28 4 14.97 1829 110 0.31 / 662.88 6 48
3 3 875.16 -2 15.31 10 0 0.11 / 662.88 6 48
4 7 2016.12 40 14.67 3182 1867 2.18 / 664.75 48 55
5 13 1986.52 20 14.62 3138 918 3.10 / 665.66 6 61
6 13 1241.68 20 14.64 2131 624 3.72 / 666.29 6 74
7 13 757.76 20 14.67 1473 432 4.15 / 666.72 6 80
8 13 72.44 20 14.84 410 122 4.28 / 666.84 6 67
9 8 0.08 272 14.80 289 1163 5.44 / 668.01 6 137
Average= 668.01
(KJ/cycle)

Cycle 124 GMT 15/ 6/2022 23:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 30 14.79 461 205 0.20 / 657.11 6 18
2 7 2020.08 40 14.67 3176 1864 2.07 / 658.97 18 57
3 13 1997.84 20 14.61 3171 927 2.99 / 659.90 6 61
4 13 1469.24 20 14.60 2450 715 3.71 / 660.61 6 73
5 13 1091.84 20 14.60 1917 560 4.27 / 661.17 6 77
6 13 290.52 20 14.76 755 223 4.49 / 661.39 6 76
7 8 0.12 272 14.79 291 1171 5.66 / 662.57 6 133
Average= 5.30
(KJ/cycle)

Cycle 123 GMT 6/ 6/2022 3:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 30 14.79 449 199 0.20 / 651.50 6 19
2 7 2015.36 40 14.67 3165 1857 2.06 / 653.35 19 58
3 13 1991.12 20 14.62 3138 918 2.97 / 654.27 6 62
4 13 1410.36 20 14.61 2371 693 3.67 / 654.96 6 73
5 13 883.72 20 14.64 1644 481 4.15 / 655.44 6 79
6 13 388.64 20 14.74 911 269 4.42 / 655.71 6 79
7 8 0.24 279 14.79 288 1188 5.61 / 656.90 6 133
Average= 5.30
(KJ/cycle)

Cycle 122 GMT 27/ 5/2022 6:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 30 14.80 446 198 0.20 / 645.64 6 19
2 10 1009.48 3 15.01 1838 83 0.28 / 645.72 6 42
3 3 959.92 -1 15.30 10 0 0.08 / 645.72 6 42
4 7 2002.76 40 14.68 3151 1850 2.13 / 647.57 42 58
5 13 1868.04 20 14.63 2985 873 3.00 / 648.45 6 64
6 13 1691.60 20 14.58 2745 800 3.80 / 649.25 6 69
7 13 928.40 20 14.64 1691 495 4.30 / 649.74 6 80
8 13 644.48 20 14.67 1289 378 4.68 / 650.12 6 82
9 8 0.00 278 14.79 286 1176 5.85 / 651.30 6 131
Average= 5.30
(KJ/cycle)

Cycle 121 GMT 17/ 5/2022 10: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 30 14.81 447 199 0.20 / 640.26 6 20
2 7 2005.92 41 14.67 3166 1904 2.10 / 642.16 20 58
3 13 1979.60 20 14.62 3146 920 3.02 / 643.08 6 61
4 13 1224.36 20 14.64 2107 617 3.64 / 643.70 6 74
5 13 708.68 20 14.69 1396 410 4.05 / 644.11 6 80
6 13 147.40 20 14.82 540 160 4.21 / 644.27 6 72
7 8 0.12 274 14.81 289 1173 5.38 / 645.44 6 131
Average= 5.29
(KJ/cycle)

Cycle 120 GMT 7/ 5/2022 13:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 30 14.79 441 196 0.20 / 634.73 6 19
2 7 2011.72 40 14.68 3177 1866 2.06 / 636.59 19 57
3 13 1981.44 20 14.64 3109 910 2.97 / 637.50 6 62
4 13 1394.28 20 14.62 2343 685 3.66 / 638.19 6 73
5 13 1014.96 20 14.62 1808 529 4.19 / 638.72 6 79
6 13 183.72 20 14.81 585 173 4.36 / 638.89 6 74
7 8 0.20 276 14.81 286 1169 5.53 / 640.06 6 132
Average= 5.29
(KJ/cycle)

Cycle 119 GMT 27/ 4/2022 16:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 30 14.83 439 195 0.20 / 629.14 6 20
2 7 2004.40 40 14.69 3145 1848 2.04 / 630.98 20 57
3 13 1976.68 20 14.64 3109 910 2.95 / 631.89 6 62
4 13 1338.52 20 14.62 2263 662 3.62 / 632.56 6 75
5 13 924.00 20 14.64 1681 492 4.11 / 633.05 6 81
6 13 494.64 20 14.72 1059 312 4.42 / 633.36 6 82
7 8 0.16 279 14.79 284 1172 5.59 / 634.53 6 137
Average= 5.29
(KJ/cycle)

Cycle 118 GMT 17/ 4/2022 19:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 30 14.82 443 197 0.20 / 623.92 6 21
2 7 2012.40 40 14.67 3172 1861 2.06 / 625.78 21 57
3 13 1879.28 20 14.62 2995 876 2.93 / 626.66 6 64
4 13 1288.36 20 14.63 2200 644 3.58 / 627.30 6 76
5 13 698.28 20 14.69 1369 402 3.98 / 627.70 6 82
6 8 0.04 293 14.83 285 1238 5.22 / 628.94 6 136
Average= 5.29
(KJ/cycle)

Cycle 117 GMT 7/ 4/2022 23: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 29 14.82 450 193 0.19 / 618.57 6 19
2 10 1003.80 3 15.00 1835 83 0.28 / 618.66 6 43
3 3 922.76 -1 15.31 9 0 0.08 / 618.66 6 43
4 7 2005.08 40 14.68 3169 1861 2.14 / 620.52 43 61
5 13 1975.60 20 14.62 3130 915 3.05 / 621.43 6 64
6 13 1297.44 20 14.63 2207 646 3.70 / 622.08 6 77
7 13 730.80 20 14.69 1419 417 4.11 / 622.49 6 82
8 13 31.96 20 14.87 338 101 4.22 / 622.59 6 67
9 8 0.16 267 14.82 285 1128 5.34 / 623.72 6 129
Average= 5.29
(KJ/cycle)

Cycle 116 GMT 29/ 3/2022 2: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 30 14.82 454 202 0.20 / 613.29 6 20
2 7 2003.72 40 14.67 3155 1851 2.05 / 615.14 20 58
3 13 1974.96 20 14.63 3116 912 2.96 / 616.05 6 63
4 13 1278.16 20 14.64 2182 639 3.60 / 616.69 6 77
5 13 769.56 20 14.68 1478 434 4.04 / 617.12 6 82
6 13 19.64 20 14.87 325 97 4.13 / 617.22 6 69
7 8 0.12 272 14.82 288 1161 5.30 / 618.38 6 137
Average= 5.29
(KJ/cycle)

Cycle 115 GMT 19/ 3/2022 5:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 30 14.81 455 202 0.20 / 607.89 6 20
2 7 2018.44 40 14.68 3180 1867 2.07 / 609.76 20 58
3 13 1993.32 20 14.63 3146 921 2.99 / 610.68 6 62
4 13 1219.68 20 14.64 2108 617 3.61 / 611.30 6 77
5 13 923.64 20 14.65 1684 493 4.10 / 611.79 6 81
6 13 17.44 20 14.87 326 97 4.20 / 611.89 6 67
7 8 0.04 276 14.82 292 1194 5.39 / 613.08 6 145
Average= 5.29
(KJ/cycle)

Cycle 114 GMT 9/ 3/2022 8:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 30 14.80 444 197 0.20 / 602.29 6 18
2 7 2003.72 40 14.67 3176 1864 2.06 / 604.15 18 58
3 13 1976.44 20 14.64 3116 912 2.97 / 605.06 6 63
4 13 1531.80 20 14.60 2544 743 3.72 / 605.81 6 73
5 13 925.88 20 14.65 1695 497 4.21 / 606.30 6 79
6 13 211.00 20 14.81 645 191 4.40 / 606.49 6 74
7 8 -0.04 279 14.81 290 1198 5.60 / 607.69 6 142
Average= 5.28
(KJ/cycle)

Cycle 113 GMT 27/ 2/2022 11:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 30 14.83 455 202 0.20 / 596.83 6 18
2 7 2006.24 41 14.68 3169 1907 2.11 / 598.74 18 58
3 13 1979.00 20 14.63 3121 913 3.02 / 599.65 6 63
4 13 1310.16 20 14.63 2229 652 3.68 / 600.31 6 76
5 13 812.00 20 14.67 1537 451 4.13 / 600.76 6 81
6 13 158.96 20 14.82 555 165 4.29 / 600.92 6 73
7 8 0.08 274 14.81 288 1169 5.46 / 602.09 6 132
Average= 5.28
(KJ/cycle)

Cycle 112 GMT 17/ 2/2022 14:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 30 14.81 447 199 0.20 / 591.41 6 18
2 7 2013.04 40 14.67 3173 1862 2.06 / 593.27 18 58
3 13 1984.72 20 14.63 3140 919 2.98 / 594.19 6 63
4 13 1380.04 20 14.62 2332 682 3.66 / 594.87 6 75
5 13 789.48 20 14.68 1504 442 4.10 / 595.31 6 80
6 13 78.88 20 14.86 424 126 4.23 / 595.44 6 69
7 8 0.08 276 14.83 291 1191 5.42 / 596.63 6 137
Average= 5.28
(KJ/cycle)

Cycle 111 GMT 7/ 2/2022 18:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 30 14.83 464 206 0.21 / 585.91 6 17
2 7 2013.80 40 14.68 3182 1868 2.07 / 587.78 17 58
3 13 1986.44 20 14.63 3145 920 3.00 / 588.70 6 62
4 13 1484.08 20 14.62 2456 718 3.71 / 589.42 6 74
5 13 822.72 20 14.68 1548 454 4.17 / 589.87 6 80
6 13 183.92 20 14.82 589 175 4.34 / 590.05 6 75
7 8 -0.12 276 14.82 285 1166 5.51 / 591.21 6 133
Average= 5.28
(KJ/cycle)

Cycle 110 GMT 28/ 1/2022 21:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 30 14.81 455 202 0.20 / 580.61 6 17
2 7 2012.60 41 14.68 3180 1914 2.12 / 582.52 17 58
3 13 1982.36 20 14.62 3139 918 3.03 / 583.44 6 63
4 13 1185.96 20 14.64 2061 603 3.64 / 584.05 6 77
5 13 665.20 20 14.70 1327 390 4.03 / 584.44 6 81
6 13 25.16 20 14.88 344 102 4.13 / 584.54 6 65
7 8 0.08 270 14.83 291 1165 5.30 / 585.70 6 129
Average= 5.28
(KJ/cycle)

Cycle 109 GMT 19/ 1/2022 0:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 30 14.84 457 203 0.20 / 575.26 6 17
2 7 2005.16 40 14.69 3168 1862 2.06 / 577.12 17 57
3 13 1975.96 20 14.64 3123 914 2.98 / 578.03 6 62
4 13 1217.76 20 14.66 2093 614 3.59 / 578.65 6 76
5 13 796.44 20 14.69 1516 445 4.04 / 579.09 6 81
6 13 96.84 20 14.85 462 137 4.18 / 579.23 6 71
7 8 0.00 274 14.82 290 1178 5.35 / 580.41 6 135
Average= 5.28
(KJ/cycle)

Cycle 108 GMT 9/ 1/2022 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 30 14.81 455 202 0.20 / 569.69 6 17
2 7 2004.00 40 14.68 3159 1855 2.06 / 571.55 17 57
3 13 1976.12 20 14.64 3128 916 2.97 / 572.46 6 61
4 13 1762.92 20 14.57 2859 833 3.81 / 573.30 6 67
5 13 837.72 20 14.68 1576 463 4.27 / 573.76 6 78
6 13 63.68 20 14.88 401 119 4.39 / 573.88 6 66
7 8 0.16 272 14.84 291 1175 5.56 / 575.05 6 133
Average= 5.28
(KJ/cycle)

Cycle 107 GMT 30/12/2021 6:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 30 14.83 447 199 0.20 / 564.16 6 17
2 7 2012.92 40 14.69 3179 1868 2.07 / 566.03 17 56
3 13 1982.20 20 14.64 3158 925 2.99 / 566.95 6 60
4 13 1421.72 20 14.63 2378 696 3.69 / 567.65 6 73
5 13 983.36 20 14.65 1767 518 4.21 / 568.17 6 79
6 13 131.88 20 14.84 506 150 4.36 / 568.32 6 71
7 8 0.08 276 14.82 287 1174 5.53 / 569.49 6 137
Average= 5.27
(KJ/cycle)

Cycle 106 GMT 20/12/2021 10: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 30 14.82 452 201 0.20 / 558.78 6 17
2 7 2004.36 40 14.69 3163 1859 2.06 / 560.64 17 59
3 13 1976.64 20 14.64 3135 918 2.98 / 561.56 6 63
4 13 1451.88 20 14.62 2425 709 3.69 / 562.26 6 71
5 13 727.48 20 14.70 1428 420 4.11 / 562.68 6 79
6 13 94.40 20 14.86 447 133 4.24 / 562.82 6 68
7 8 0.12 270 14.83 286 1145 5.38 / 563.96 6 130
Average= 5.27
(KJ/cycle)

Cycle 105 GMT 10/12/2021 13:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 30 14.83 445 198 0.20 / 553.22 6 17
2 7 2011.60 40 14.69 3171 1863 2.06 / 555.08 17 56
3 13 1980.80 20 14.65 3122 915 2.98 / 555.99 6 62
4 13 1463.36 20 14.63 2454 718 3.69 / 556.71 6 72
5 13 938.36 20 14.66 1706 500 4.19 / 557.21 6 79
6 13 279.20 20 14.80 735 218 4.41 / 557.43 6 76
7 8 0.20 270 14.82 287 1148 5.56 / 558.58 6 138
Average= 5.27
(KJ/cycle)

Cycle 104 GMT 30/11/2021 16:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 30 14.83 451 201 0.20 / 547.87 6 14
2 7 2011.60 41 14.68 3171 1909 2.11 / 549.78 14 59
3 13 1980.28 20 14.64 3124 915 3.02 / 550.69 6 62
4 13 1261.52 20 14.64 2156 631 3.66 / 551.33 6 73
5 13 679.84 20 14.71 1341 395 4.05 / 551.72 6 79
6 13 172.76 20 14.83 572 170 4.22 / 551.89 6 72
7 8 0.24 267 14.83 285 1128 5.35 / 553.02 6 131
Average= 5.27
(KJ/cycle)

Cycle 103 GMT 20/11/2021 19:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 30 14.83 465 207 0.21 / 542.38 6 15
2 7 2013.32 41 14.69 3170 1909 2.12 / 544.29 15 59
3 13 1983.64 20 14.65 3121 914 3.03 / 545.20 6 62
4 13 1360.88 20 14.64 2302 674 3.70 / 545.87 6 73
5 13 774.64 20 14.69 1489 437 4.14 / 546.31 6 79
6 13 256.56 20 14.81 708 210 4.35 / 546.52 6 76
7 8 0.08 270 14.83 287 1149 5.50 / 547.67 6 133
Average= 5.27
(KJ/cycle)

Cycle 102 GMT 10/11/2021 22:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 30 14.83 460 205 0.20 / 536.75 6 15
2 7 2014.36 41 14.69 3188 1920 2.12 / 538.67 15 58
3 13 1983.00 20 14.64 3136 918 3.04 / 539.59 6 62
4 13 1635.64 20 14.60 2676 781 3.82 / 540.37 6 70
5 13 726.60 20 14.71 1424 419 4.24 / 540.79 6 81
6 13 284.88 20 14.81 746 221 4.46 / 541.01 6 77
7 8 0.08 272 14.83 288 1162 5.63 / 542.17 6 129
Average= 5.26
(KJ/cycle)

Cycle 101 GMT 1/11/2021 2:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 30 14.85 453 202 0.20 / 531.16 6 14
2 7 2012.20 41 14.69 3170 1909 2.11 / 533.07 14 61
3 13 1981.36 20 14.64 3145 921 3.03 / 533.99 6 63
4 13 1559.12 20 14.62 2574 753 3.78 / 534.75 6 72
5 13 837.80 20 14.68 1575 462 4.25 / 535.21 6 80
6 13 49.44 20 14.87 397 118 4.37 / 535.33 6 67
7 8 0.12 274 14.84 299 1216 5.58 / 536.54 6 131
Average= 5.26
(KJ/cycle)

Cycle 100 GMT 22/10/2021 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 30 14.83 464 206 0.21 / 525.77 6 14
2 7 2011.60 40 14.70 3173 1866 2.07 / 527.63 14 57
3 13 1984.12 20 14.65 3139 920 2.99 / 528.55 6 61
4 13 1526.36 20 14.63 2518 737 3.73 / 529.29 6 71
5 13 704.08 20 14.72 1378 406 4.13 / 529.70 6 81
6 13 40.52 20 14.89 358 107 4.24 / 529.80 6 68
7 8 0.20 274 14.85 285 1160 5.40 / 530.96 6 145
Average= 5.26
(KJ/cycle)

Cycle 99 GMT 12/10/2021 8:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 30 14.83 442 197 0.20 / 520.21 6 15
2 7 2013.52 40 14.70 3168 1863 2.06 / 522.07 15 58
3 13 1982.68 20 14.64 3133 917 2.98 / 522.99 6 63
4 13 1407.12 20 14.64 2360 691 3.67 / 523.68 6 75
5 13 980.40 20 14.66 1759 516 4.18 / 524.20 6 79
6 13 270.32 20 14.80 734 217 4.40 / 524.42 6 76
7 8 0.08 272 14.83 284 1146 5.55 / 525.56 6 129
Average= 5.26
(KJ/cycle)

Cycle 98 GMT 2/10/2021 11:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 30 14.84 460 205 0.20 / 514.48 6 14
2 7 2003.24 40 14.70 3158 1857 2.06 / 516.34 14 59
3 13 1973.52 20 14.66 3112 912 2.97 / 517.25 6 62
4 13 1331.64 20 14.66 2257 662 3.64 / 517.92 6 76
5 13 1228.72 20 14.61 2113 617 4.25 / 518.53 6 76
6 13 522.04 20 14.73 1105 326 4.58 / 518.86 6 83
7 8 0.08 274 14.82 285 1157 5.74 / 520.02 6 142
Average= 5.25
(KJ/cycle)

Cycle 97 GMT 22/ 9/2021 15:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 30 14.84 449 200 0.20 / 509.01 6 14
2 7 2013.56 40 14.70 3162 1859 2.06 / 510.87 14 57
3 13 1983.80 20 14.65 3124 915 2.97 / 511.79 6 63
4 13 1351.16 20 14.65 2286 670 3.64 / 512.46 6 74
5 13 891.64 20 14.68 1639 481 4.13 / 512.94 6 80
6 13 221.80 20 14.83 642 190 4.32 / 513.13 6 76
7 8 0.16 272 14.84 285 1150 5.47 / 514.28 6 129
Average= 5.25
(KJ/cycle)

Cycle 96 GMT 12/ 9/2021 18:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 30 14.85 443 197 0.20 / 503.46 6 14
2 7 2012.12 40 14.71 3163 1861 2.06 / 505.32 14 55
3 13 1985.04 20 14.67 3136 920 2.98 / 506.24 6 58
4 13 1503.20 20 14.64 2489 729 3.71 / 506.97 6 70
5 13 1071.88 20 14.64 1889 553 4.26 / 507.52 6 76
6 13 72.44 20 14.88 411 122 4.38 / 507.65 6 67
7 8 0.12 274 14.84 287 1167 5.55 / 508.81 6 138
Average= 5.25
(KJ/cycle)

Cycle 95 GMT 2/ 9/2021 21:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 30 14.85 455 203 0.20 / 498.23 6 15
2 7 2011.52 41 14.71 3162 1907 2.11 / 500.14 15 56
3 13 1879.00 20 14.67 2993 878 2.99 / 501.02 6 63
4 13 1198.04 20 14.67 2064 606 3.59 / 501.62 6 75
5 13 687.72 20 14.72 1361 401 3.99 / 502.02 6 81
6 13 49.48 20 14.88 376 112 4.11 / 502.13 6 70
7 8 0.08 267 14.85 285 1130 5.24 / 503.26 6 135
Average= 5.24
(KJ/cycle)

Cycle 94 GMT 24/ 8/2021 0:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 30 14.84 462 206 0.21 / 492.83 6 17
2 7 2010.32 41 14.70 3170 1911 2.12 / 494.74 17 59
3 13 1979.64 20 14.67 3116 914 3.03 / 495.66 6 62
4 13 1444.04 20 14.65 2417 708 3.74 / 496.36 6 74
5 13 537.48 20 14.77 1134 335 4.07 / 496.70 6 79
6 13 188.32 20 14.85 593 176 4.25 / 496.88 6 74
7 8 0.24 270 14.86 287 1152 5.40 / 498.03 6 138
Average= 5.24
(KJ/cycle)

Cycle 93 GMT 14/ 8/2021 4: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.20 30 14.85 451 201 0.20 / 487.32 6 17
2 7 2003.08 40 14.71 3152 1855 2.06 / 489.17 6 57
3 13 1972.16 20 14.67 3125 917 2.97 / 490.09 6 61
4 13 1430.68 20 14.65 2402 704 3.68 / 490.79 6 73
5 13 847.32 20 14.70 1587 467 4.14 / 491.26 6 80
6 13 201.12 20 14.85 615 183 4.33 / 491.44 6 75
7 8 0.12 274 14.85 291 1184 5.51 / 492.63 6 135
Average= 5.24
(KJ/cycle)

Cycle 92 GMT 4/ 8/2021 7:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 30 14.86 464 207 0.21 / 481.86 6 18
2 7 2005.36 40 14.72 3159 1860 2.07 / 483.72 18 56
3 13 1980.08 20 14.67 3117 915 2.98 / 484.63 6 61
4 13 1442.08 20 14.65 2416 708 3.69 / 485.34 6 72
5 13 838.80 20 14.70 1566 460 4.15 / 485.80 6 80
6 13 147.40 20 14.87 530 158 4.31 / 485.96 6 74
7 8 0.00 272 14.86 287 1160 5.47 / 487.12 6 138
Average= 5.24
(KJ/cycle)

Cycle 91 GMT 25/ 7/2021 10:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 30 14.85 464 207 0.21 / 476.28 6 18
2 7 2005.44 40 14.72 3161 1861 2.07 / 478.14 18 57
3 13 1975.60 20 14.67 3123 916 2.98 / 479.05 6 63
4 13 1633.68 20 14.63 2678 784 3.77 / 479.84 6 71
5 13 904.16 20 14.70 1660 488 4.26 / 480.33 6 80
6 13 112.64 20 14.89 477 142 4.40 / 480.47 6 74
7 8 0.08 272 14.87 292 1181 5.58 / 481.65 6 135
Average= 5.24
(KJ/cycle)

Cycle 90 GMT 15/ 7/2021 14:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 30 14.85 454 202 0.20 / 470.82 6 22
2 7 2003.68 40 14.71 3160 1859 2.06 / 472.68 22 58
3 13 1971.12 20 14.67 3135 920 2.98 / 473.60 6 63
4 13 1239.68 20 14.67 2132 626 3.61 / 474.23 6 77
5 13 763.08 20 14.72 1469 432 4.04 / 474.66 6 82
6 13 260.96 20 14.83 715 212 4.25 / 474.87 6 80
7 8 0.08 274 14.85 295 1200 5.45 / 476.07 6 134
Average= 5.23
(KJ/cycle)

Cycle 89 GMT 5/ 7/2021 17:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 30 14.85 461 205 0.21 / 465.41 6 20
2 7 2010.52 40 14.70 3171 1865 2.07 / 467.28 20 58
3 13 1978.40 20 14.67 3114 914 2.98 / 468.19 6 64
4 13 1227.84 20 14.67 2118 621 3.60 / 468.81 6 77
5 13 760.08 20 14.72 1469 432 4.04 / 469.25 6 83
6 13 195.00 20 14.85 608 181 4.22 / 469.43 6 79
7 8 0.08 274 14.85 293 1192 5.41 / 470.62 6 140
Average= 5.23
(KJ/cycle)

Cycle 88 GMT 25/ 6/2021 20:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 30 14.85 453 202 0.20 / 460.02 6 21
2 7 2012.16 40 14.72 3163 1862 2.06 / 461.88 21 57
3 13 1981.48 20 14.66 3135 919 2.98 / 462.80 6 62
4 13 1390.80 20 14.66 2353 690 3.67 / 463.49 6 76
5 13 680.56 20 14.74 1354 399 4.07 / 463.89 6 82
6 13 53.16 20 14.91 391 117 4.19 / 464.01 6 72
7 8 0.00 274 14.86 295 1201 5.39 / 465.21 6 130
Average= 5.23
(KJ/cycle)

Cycle 87 GMT 15/ 6/2021 23:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 30 14.86 454 202 0.20 / 454.65 6 20
2 7 2013.28 40 14.71 3172 1866 2.07 / 456.52 20 58
3 13 1984.84 20 14.66 3131 918 2.99 / 457.43 6 64
4 13 1177.72 20 14.68 2057 604 3.59 / 458.04 6 76
5 13 953.04 20 14.68 1725 506 4.10 / 458.54 6 81
6 13 29.68 20 14.91 343 102 4.20 / 458.65 6 71
7 8 -0.04 272 14.86 290 1172 5.37 / 459.82 6 133
Average= 5.23
(KJ/cycle)

Cycle 86 GMT 6/ 6/2021 2:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 30 14.83 455 202 0.20 / 449.09 6 26
2 10 1002.60 3 15.04 1840 83 0.29 / 449.17 6 55
3 7 2005.88 40 14.71 3167 1863 2.15 / 451.03 55 58
4 13 1975.04 20 14.66 3124 916 3.06 / 451.95 6 62
5 13 1395.92 20 14.66 2361 692 3.76 / 452.64 6 75
6 13 949.00 20 14.69 1725 507 4.26 / 453.15 6 82
7 13 60.00 20 14.90 396 118 4.38 / 453.27 6 72
8 8 0.08 272 14.86 292 1180 5.56 / 454.45 6 129
Average= 5.22
(KJ/cycle)

Cycle 85 GMT 27/ 5/2021 5:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 30 14.86 466 208 0.21 / 443.45 6 21
2 7 2017.04 40 14.71 3188 1876 2.08 / 445.33 21 58
3 13 1990.52 20 14.67 3149 924 3.01 / 446.25 6 63
4 13 1409.64 20 14.66 2372 695 3.70 / 446.95 6 75
5 13 911.72 20 14.70 1666 490 4.19 / 447.44 6 81
6 13 289.64 20 14.82 768 228 4.42 / 447.67 6 82
7 8 0.04 278 14.85 295 1218 5.64 / 448.88 6 140
Average= 5.22
(KJ/cycle)

Cycle 84 GMT 17/ 5/2021 9:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 30 14.86 462 206 0.21 / 437.99 6 23
2 7 2016.80 40 14.71 3172 1866 2.07 / 439.85 23 57
3 13 1988.56 20 14.67 3146 923 3.00 / 440.78 6 63
4 13 1413.00 20 14.66 2379 698 3.69 / 441.47 6 73
5 13 803.88 20 14.72 1521 448 4.14 / 441.92 6 82
6 13 95.92 20 14.90 454 135 4.28 / 442.06 6 73
7 8 0.12 272 14.87 294 1189 5.47 / 443.25 6 132
Average= 5.21
(KJ/cycle)

Cycle 83 GMT 7/ 5/2021 12:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 30 14.87 453 202 0.20 / 432.67 6 22
2 7 2010.68 40 14.72 3153 1856 2.06 / 434.52 22 58
3 13 1977.96 20 14.68 3113 914 2.97 / 435.44 6 62
4 13 1387.40 20 14.67 2334 685 3.66 / 436.12 6 74
5 13 567.40 20 14.78 1178 348 4.01 / 436.47 6 81
6 13 97.28 20 14.90 449 134 4.14 / 436.60 6 74
7 8 0.16 274 14.87 289 1177 5.32 / 437.78 6 137
Average= 5.21
(KJ/cycle)

Cycle 82 GMT 27/ 4/2021 15:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 30 14.88 450 201 0.20 / 427.30 6 26
2 7 2012.40 40 14.72 3162 1862 2.06 / 429.16 26 56
3 13 1980.76 20 14.68 3114 914 2.98 / 430.07 6 62
4 13 1330.28 20 14.68 2252 661 3.64 / 430.73 6 76
5 13 885.60 20 14.70 1631 480 4.12 / 431.21 6 81
6 13 20.76 20 14.92 327 98 4.22 / 431.31 6 69
7 8 0.08 270 14.87 287 1152 5.37 / 432.46 6 132
Average= 5.21
(KJ/cycle)

Cycle 81 GMT 17/ 4/2021 18:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 30 14.87 463 207 0.21 / 422.01 6 23
2 7 2004.24 41 14.73 3150 1902 2.11 / 423.91 23 57
3 13 1971.24 20 14.68 3106 912 3.02 / 424.82 6 62
4 13 1327.04 20 14.68 2250 661 3.68 / 425.48 6 73
5 13 648.52 20 14.76 1305 385 4.07 / 425.87 6 81
6 8 0.08 285 14.89 289 1226 5.29 / 427.10 6 135
Average= 5.21
(KJ/cycle)

Cycle 80 GMT 7/ 4/2021 21:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 30 14.85 466 208 0.21 / 416.58 6 26
2 7 2015.64 41 14.72 3166 1911 2.12 / 418.49 26 57
3 13 1985.24 20 14.68 3115 915 3.03 / 419.41 6 62
4 13 1373.68 20 14.67 2318 680 3.71 / 420.09 6 73
5 13 769.00 20 14.73 1482 437 4.15 / 420.53 6 82
6 13 26.60 20 14.93 341 102 4.25 / 420.63 6 69
7 8 0.08 267 14.88 296 1176 5.43 / 421.80 6 140
Average= 5.21
(KJ/cycle)

Cycle 79 GMT 29/ 3/2021 0:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 30 14.86 458 204 0.20 / 411.18 6 25
2 7 2011.08 41 14.72 3176 1917 2.12 / 413.09 25 58
3 13 1981.16 20 14.69 3136 921 3.04 / 414.01 6 63
4 13 1178.76 20 14.70 2046 602 3.64 / 414.62 6 76
5 13 594.52 20 14.78 1226 362 4.01 / 414.98 6 82
6 13 279.12 20 14.85 743 221 4.23 / 415.20 6 79
7 8 0.08 272 14.87 291 1177 5.40 / 416.38 6 138
Average= 5.20
(KJ/cycle)

Cycle 78 GMT 19/ 3/2021 3:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 30 14.86 455 203 0.20 / 405.75 6 29
2 7 2010.88 40 14.73 3159 1861 2.06 / 407.61 29 57
3 13 1978.56 20 14.68 3117 915 2.98 / 408.53 6 62
4 13 1353.20 20 14.68 2280 669 3.65 / 409.19 6 76
5 13 778.84 20 14.73 1498 441 4.09 / 409.64 6 81
6 13 136.16 20 14.89 515 153 4.24 / 409.79 6 75
7 8 0.00 276 14.88 288 1183 5.43 / 410.97 6 140
Average= 5.20
(KJ/cycle)

Cycle 77 GMT 9/ 3/2021 7: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 29 14.86 461 199 0.20 / 400.33 6 27
2 7 2006.04 40 14.73 3156 1860 2.06 / 402.19 27 57
3 13 1979.84 20 14.69 3118 916 2.97 / 403.10 6 61
4 13 1222.36 20 14.70 2102 618 3.59 / 403.72 6 74
5 13 708.04 20 14.75 1398 412 4.00 / 404.13 6 83
6 13 217.00 20 14.87 656 195 4.20 / 404.33 6 79
7 8 0.00 276 14.87 297 1219 5.42 / 405.55 6 132
Average= 5.20
(KJ/cycle)

Cycle 76 GMT 27/ 2/2021 10:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 29 14.87 462 199 0.20 / 395.01 6 28
2 7 2013.52 40 14.73 3174 1870 2.07 / 396.88 28 58
3 13 1989.04 20 14.68 3149 925 2.99 / 397.80 6 62
4 13 1226.44 20 14.71 2111 621 3.61 / 398.42 6 77
5 13 676.76 20 14.76 1340 396 4.01 / 398.82 6 82
6 8 0.08 293 14.88 300 1308 5.32 / 400.13 6 134
Average= 5.20
(KJ/cycle)

Cycle 75 GMT 17/ 2/2021 13:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 29 14.87 460 198 0.20 / 389.62 6 26
2 7 2015.32 41 14.72 3170 1913 2.11 / 391.54 26 57
3 13 1985.72 20 14.68 3136 921 3.03 / 392.46 6 64
4 13 1372.48 20 14.68 2316 680 3.71 / 393.14 6 75
5 13 659.80 20 14.76 1327 392 4.10 / 393.53 6 84
6 13 88.92 20 14.91 439 131 4.23 / 393.66 6 74
7 8 0.04 267 14.88 289 1148 5.38 / 394.81 6 134
Average= 5.19
(KJ/cycle)

Cycle 74 GMT 7/ 2/2021 16:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 29 14.87 464 200 0.20 / 384.31 6 24
2 7 2010.60 40 14.73 3156 1860 2.06 / 386.17 24 58
3 13 1978.68 20 14.69 3122 917 2.98 / 387.09 6 63
4 13 1366.76 20 14.68 2302 676 3.65 / 387.76 6 75
5 13 559.92 20 14.79 1170 346 4.00 / 388.11 6 83
6 13 16.16 20 14.94 336 100 4.10 / 388.21 6 71
7 8 0.16 274 14.88 298 1215 5.31 / 389.43 6 130
Average= 5.19
(KJ/cycle)

Cycle 73 GMT 28/ 1/2021 19:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 29 14.85 460 198 0.20 / 378.93 6 25
2 7 2015.96 40 14.73 3175 1871 2.07 / 380.80 25 58
3 13 1986.28 20 14.69 3139 922 2.99 / 381.73 6 64
4 13 1359.04 20 14.68 2300 675 3.67 / 382.40 6 76
5 13 642.80 20 14.77 1300 384 4.05 / 382.79 6 83
6 13 124.04 20 14.90 494 147 4.20 / 382.93 6 77
7 8 0.00 274 14.88 289 1178 5.38 / 384.11 6 134
Average= 5.19
(KJ/cycle)

Cycle 72 GMT 18/ 1/2021 22:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 29 14.89 455 196 0.20 / 373.37 6 22
2 7 2010.56 40 14.73 3176 1871 2.07 / 375.24 22 57
3 13 1979.44 20 14.68 3128 918 2.99 / 376.16 6 62
4 13 1353.56 20 14.68 2296 674 3.66 / 376.84 6 76
5 13 774.08 20 14.74 1481 437 4.10 / 377.27 6 82
6 13 365.00 20 14.82 866 257 4.35 / 377.53 6 82
7 8 0.04 280 14.86 290 1207 5.56 / 378.74 6 136
Average= 5.19
(KJ/cycle)

Cycle 71 GMT 9/ 1/2021 2:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 29 14.87 461 199 0.20 / 368.16 6 22
2 7 2013.56 40 14.73 3189 1879 2.08 / 370.04 22 58
3 13 1982.44 20 14.69 3123 918 3.00 / 370.96 6 63
4 13 1249.52 20 14.69 2137 628 3.62 / 371.59 6 77
5 13 500.96 20 14.81 1078 319 3.94 / 371.91 6 82
6 13 75.68 20 14.92 417 124 4.07 / 372.03 6 73
7 8 0.28 267 14.89 288 1145 5.21 / 373.18 6 133
Average= 5.18
(KJ/cycle)

Cycle 70 GMT 30/12/2020 5: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 29 14.88 453 195 0.20 / 362.71 6 20
2 7 2012.64 41 14.72 3176 1917 2.11 / 364.62 20 59
3 13 1982.16 20 14.69 3129 919 3.03 / 365.54 6 64
4 13 1327.28 20 14.69 2250 661 3.69 / 366.20 6 77
5 13 847.44 20 14.72 1581 465 4.16 / 366.67 6 83
6 13 79.44 20 14.91 423 126 4.28 / 366.80 6 73
7 8 -0.04 267 14.88 294 1168 5.45 / 367.96 6 131
Average= 5.18
(KJ/cycle)

Cycle 69 GMT 20/12/2020 8:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 29 14.88 450 194 0.19 / 357.33 6 22
2 7 2004.88 41 14.73 3171 1915 2.11 / 359.24 22 58
3 13 1974.88 20 14.69 3123 918 3.03 / 360.16 6 62
4 13 1305.88 20 14.69 2236 657 3.68 / 360.82 6 77
5 13 741.52 20 14.75 1430 422 4.11 / 361.24 6 82
6 13 73.28 20 14.92 414 124 4.23 / 361.36 6 70
7 8 -0.04 268 14.88 288 1148 5.38 / 362.51 6 136
Average= 5.18
(KJ/cycle)

Cycle 68 GMT 10/12/2020 11:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 29 14.89 460 199 0.20 / 351.79 6 16
2 7 2003.28 40 14.74 3162 1864 2.06 / 353.66 16 60
3 13 1971.64 20 14.70 3116 916 2.98 / 354.57 6 64
4 13 1632.28 20 14.66 2673 784 3.76 / 355.36 6 71
5 13 944.80 20 14.71 1711 503 4.27 / 355.86 6 80
6 13 130.96 20 14.91 508 151 4.42 / 356.01 6 74
7 8 0.32 263 14.89 287 1124 5.54 / 357.13 6 133
Average= 5.18
(KJ/cycle)

Cycle 67 GMT 30/11/2020 14:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 29 14.88 446 192 0.19 / 346.52 6 17
2 7 2004.88 40 14.74 3166 1867 2.06 / 348.39 17 57
3 13 1905.32 20 14.70 3049 896 2.96 / 349.28 6 65
4 13 1229.56 20 14.71 2120 624 3.58 / 349.91 6 76
5 13 703.68 20 14.76 1383 408 3.99 / 350.32 6 82
6 13 62.80 20 14.92 401 120 4.11 / 350.44 6 70
7 8 0.12 267 14.89 291 1157 5.26 / 351.59 6 133
Average= 5.17
(KJ/cycle)

Cycle 66 GMT 20/11/2020 17:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 29 14.89 448 193 0.19 / 341.23 6 19
2 7 2017.04 40 14.75 3170 1870 2.06 / 343.10 19 57
3 13 1987.56 20 14.70 3136 922 2.99 / 344.02 6 62
4 13 1337.84 20 14.70 2259 664 3.65 / 344.68 6 74
5 13 530.68 20 14.81 1122 332 3.98 / 345.02 6 81
6 13 165.72 20 14.90 562 167 4.15 / 345.18 6 75
7 8 0.08 266 14.89 289 1145 5.29 / 346.33 6 134
Average= 5.17
(KJ/cycle)

Cycle 65 GMT 10/11/2020 21: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 29 14.89 458 198 0.20 / 335.79 6 17
2 7 2014.00 41 14.75 3169 1916 2.11 / 337.71 17 56
3 13 1985.08 20 14.70 3122 918 3.03 / 338.63 6 62
4 13 1427.84 20 14.69 2391 702 3.73 / 339.33 6 73
5 13 644.56 20 14.79 1295 383 4.12 / 339.71 6 81
6 13 181.88 20 14.90 589 176 4.29 / 339.89 6 76
7 8 0.20 267 14.90 288 1146 5.44 / 341.03 6 130
Average= 5.17
(KJ/cycle)

Cycle 64 GMT 1/11/2020 0:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 29 14.90 450 194 0.19 / 330.16 6 14
2 3 1021.96 1 15.11 1885 28 0.22 / 330.19 6 6
3 7 2015.20 40 14.75 3165 1867 2.09 / 332.06 6 57
4 13 1987.88 20 14.70 3120 917 3.01 / 332.98 6 62
5 13 1509.92 20 14.69 2503 735 3.74 / 333.71 6 72
6 13 820.56 20 14.76 1542 455 4.20 / 334.17 6 80
7 13 363.84 20 14.85 870 258 4.46 / 334.42 6 82
8 8 0.20 270 14.90 291 1171 5.63 / 335.60 6 139
Average= 5.16
(KJ/cycle)

Cycle 63 GMT 22/10/2020 3:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 29 14.91 454 196 0.20 / 325.02 6 16
2 10 1005.24 2 15.09 1835 55 0.25 / 325.07 6 44
3 3 967.40 -1 15.39 10 0 0.06 / 325.07 6 44
4 7 2004.32 40 14.76 3158 1864 2.12 / 326.94 44 56
5 13 1733.04 20 14.73 2823 832 2.95 / 327.77 6 68
6 13 1166.40 20 14.74 2029 598 3.55 / 328.37 6 75
7 13 537.92 20 14.83 1135 337 3.88 / 328.70 6 81
8 13 57.56 20 14.95 395 118 4.00 / 328.82 6 72
9 8 0.16 264 14.91 291 1145 5.15 / 329.97 6 130
Average= 5.16
(KJ/cycle)

Cycle 62 GMT 12/10/2020 6:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 29 14.93 441 191 0.19 / 319.63 6 14
2 7 2010.80 40 14.76 3173 1873 2.06 / 321.51 14 57
3 13 1841.08 20 14.73 2945 868 2.93 / 322.37 6 65
4 13 1292.24 20 14.73 2208 650 3.58 / 323.02 6 75
5 13 967.12 20 14.74 1744 514 4.10 / 323.54 6 80
6 13 72.00 20 14.95 418 125 4.22 / 323.66 6 72
7 8 0.04 265 14.92 293 1158 5.38 / 324.82 6 130
Average= 5.16
(KJ/cycle)

Cycle 61 GMT 2/10/2020 9:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 29 14.93 453 196 0.20 / 314.25 6 14
2 7 2005.36 40 14.77 3169 1872 2.07 / 316.12 14 58
3 13 1974.72 20 14.73 3123 920 2.99 / 317.04 6 62
4 13 1264.80 20 14.74 2173 641 3.63 / 317.68 6 75
5 13 873.56 20 14.77 1614 477 4.11 / 318.16 6 80
6 13 60.16 20 14.97 393 118 4.22 / 318.27 6 72
7 8 0.32 270 14.93 290 1169 5.39 / 319.44 6 139
Average= 5.15
(KJ/cycle)

Cycle 60 GMT 22/ 9/2020 13: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 29 14.96 450 195 0.20 / 308.99 6 17
2 7 2004.64 40 14.77 3161 1868 2.06 / 310.86 17 57
3 13 1974.08 20 14.73 3098 913 2.98 / 311.77 6 63
4 13 1104.60 20 14.77 1930 570 3.55 / 312.34 6 77
5 13 692.32 20 14.82 1361 403 3.95 / 312.74 6 82
6 13 78.40 20 14.97 433 130 4.08 / 312.87 6 73
7 8 0.12 265 14.94 297 1176 5.25 / 314.05 6 137
Average= 5.15
(KJ/cycle)

Cycle 59 GMT 12/ 9/2020 16:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 29 14.96 460 200 0.20 / 303.68 6 21
2 7 2015.72 40 14.77 3181 1879 2.08 / 305.56 21 58
3 13 1988.00 20 14.73 3135 924 3.00 / 306.48 6 63
4 13 1381.00 20 14.73 2322 684 3.69 / 307.17 6 75
5 13 620.00 20 14.84 1260 374 4.06 / 307.54 6 82
6 13 35.24 20 15.00 353 106 4.17 / 307.65 6 71
7 8 0.28 265 14.96 290 1150 5.32 / 308.79 6 139
Average= 5.15
(KJ/cycle)

Cycle 58 GMT 2/ 9/2020 19:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 29 14.98 445 193 0.19 / 298.38 6 19
2 7 2012.72 40 14.78 3166 1872 2.07 / 300.25 19 58
3 13 1982.24 20 14.74 3129 922 2.99 / 301.17 6 63
4 13 1249.80 20 14.76 2142 632 3.62 / 301.80 6 75
5 13 734.24 20 14.81 1429 423 4.04 / 302.23 6 82
6 13 35.36 20 15.01 352 106 4.15 / 302.33 6 71
7 8 0.16 265 14.97 289 1146 5.30 / 303.48 6 134
Average= 5.14
(KJ/cycle)

Cycle 57 GMT 23/ 8/2020 22: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 29 14.98 454 197 0.20 / 292.96 6 16
2 7 2005.36 40 14.79 3167 1874 2.07 / 294.84 16 57
3 13 1907.44 20 14.75 3023 892 2.96 / 295.73 6 64
4 13 1513.44 20 14.73 2510 739 3.70 / 296.47 6 72
5 13 769.24 20 14.82 1480 439 4.14 / 296.91 6 82
6 13 95.52 20 15.00 450 135 4.28 / 297.04 6 74
7 8 0.16 265 14.98 288 1143 5.42 / 298.18 6 140
Average= 5.14
(KJ/cycle)

Cycle 56 GMT 14/ 8/2020 1:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 29 15.00 453 197 0.20 / 287.69 6 20
2 7 2004.24 40 14.79 3164 1872 2.07 / 289.56 6 58
3 13 1975.52 20 14.74 3126 922 2.99 / 290.49 6 62
4 13 1223.64 20 14.77 2108 623 3.61 / 291.11 6 75
5 13 632.88 20 14.86 1273 378 3.99 / 291.49 6 82
6 13 27.84 20 15.03 354 106 4.10 / 291.59 6 72
7 8 0.12 265 14.98 295 1171 5.27 / 292.76 6 136
Average= 5.14
(KJ/cycle)

Cycle 55 GMT 4/ 8/2020 4:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 29 15.01 453 197 0.20 / 282.40 6 22
2 7 2003.84 40 14.80 3147 1863 2.06 / 284.26 22 59
3 13 1973.52 20 14.76 3105 917 2.98 / 285.18 6 62
4 13 1241.40 20 14.78 2132 630 3.61 / 285.81 6 76
5 13 753.36 20 14.84 1447 429 4.04 / 286.24 6 82
6 13 21.64 20 15.05 337 101 4.14 / 286.34 6 72
7 8 0.08 261 15.00 295 1155 5.29 / 287.50 6 130
Average= 5.13
(KJ/cycle)

Cycle 54 GMT 25/ 7/2020 7:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 29 15.02 461 201 0.20 / 276.96 6 18
2 7 2010.12 40 14.79 3167 1874 2.07 / 278.83 18 60
3 13 1978.88 20 14.75 3128 923 3.00 / 279.75 6 64
4 13 1586.96 20 14.72 2600 765 3.76 / 280.52 6 72
5 13 698.00 20 14.87 1377 410 4.17 / 280.93 6 82
6 13 31.40 20 15.06 350 105 4.28 / 281.03 6 72
7 8 0.12 268 15.01 291 1171 5.45 / 282.20 6 143
Average= 5.13
(KJ/cycle)

Cycle 53 GMT 15/ 7/2020 10:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 29 15.02 463 202 0.20 / 271.70 6 22
2 7 2005.64 41 14.80 3161 1918 2.12 / 273.62 22 61
3 13 1975.08 20 14.75 3119 920 3.04 / 274.54 6 63
4 13 1117.04 20 14.81 1960 581 3.62 / 275.12 6 77
5 13 715.68 20 14.87 1411 420 4.04 / 275.54 6 83
6 13 31.48 20 15.06 351 106 4.15 / 275.64 6 73
7 8 0.04 253 15.02 293 1113 5.26 / 276.75 6 130
Average= 5.13
(KJ/cycle)

Cycle 52 GMT 5/ 7/2020 13:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 29 15.02 454 198 0.20 / 266.28 6 26
2 7 2011.04 40 14.80 3167 1875 2.07 / 268.15 26 61
3 13 1843.80 20 14.77 2951 872 2.94 / 269.02 6 67
4 13 1405.48 20 14.76 2362 697 3.64 / 269.72 6 75
5 13 903.04 20 14.83 1648 489 4.13 / 270.21 6 82
6 13 86.56 20 15.06 441 133 4.26 / 270.34 6 76
7 8 0.12 261 15.03 294 1153 5.42 / 271.50 6 135
Average= 5.12
(KJ/cycle)

Cycle 51 GMT 25/ 6/2020 16:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 29 15.05 446 195 0.19 / 260.76 6 26
2 7 2004.56 40 14.80 3163 1872 2.07 / 262.64 26 60
3 13 1975.80 20 14.76 3127 923 2.99 / 263.56 6 64
4 13 1267.28 20 14.80 2168 642 3.63 / 264.20 6 76
5 13 844.20 20 14.85 1579 469 4.10 / 264.67 6 82
6 13 247.68 20 15.00 689 207 4.31 / 264.88 6 82
7 8 0.04 272 15.03 294 1202 5.51 / 266.08 6 131
Average= 5.12
(KJ/cycle)

Cycle 50 GMT 15/ 6/2020 19:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 29 15.05 464 203 0.20 / 255.36 6 24
2 7 2012.64 40 14.80 3181 1883 2.09 / 257.25 24 61
3 13 1981.52 20 14.76 3119 921 3.01 / 258.17 6 63
4 13 1374.20 20 14.78 2308 682 3.69 / 258.85 6 76
5 13 716.96 20 14.90 1397 416 4.10 / 259.27 6 83
6 13 25.44 20 15.10 342 103 4.21 / 259.37 6 73
7 8 0.12 270 15.05 295 1199 5.41 / 260.57 6 144
Average= 5.11
(KJ/cycle)

Cycle 49 GMT 5/ 6/2020 22:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 29 15.05 462 202 0.20 / 250.11 6 22
2 7 2004.20 40 14.81 3149 1865 2.07 / 251.97 22 60
3 13 1972.00 20 14.77 3104 917 2.98 / 252.89 6 63
4 13 1247.32 20 14.81 2139 634 3.62 / 253.53 6 76
5 13 557.20 20 14.95 1169 350 3.97 / 253.87 6 83
6 13 85.12 20 15.09 438 132 4.10 / 254.01 6 76
7 8 0.12 261 15.06 294 1156 5.25 / 255.16 6 132
Average= 5.10
(KJ/cycle)

Cycle 48 GMT 27/ 5/2020 1:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 29 15.05 467 204 0.20 / 244.69 6 28
2 10 1002.48 3 15.14 1813 82 0.29 / 244.77 6 46
3 3 913.16 -1 15.44 10 0 0.08 / 244.77 6 46
4 7 2011.88 40 14.81 3163 1874 2.16 / 246.65 46 61
5 13 1981.88 20 14.77 3114 920 3.08 / 247.57 6 63
6 13 1275.72 20 14.81 2181 646 3.73 / 248.21 6 76
7 13 676.04 20 14.92 1339 400 4.13 / 248.61 6 82
8 13 16.32 20 15.11 333 101 4.23 / 248.71 6 72
9 8 0.00 265 15.06 299 1193 5.42 / 249.91 6 133
Average= 5.10
(KJ/cycle)

Cycle 47 GMT 17/ 5/2020 4:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 29 15.07 467 204 0.20 / 239.32 6 23
2 7 2005.56 41 14.81 3170 1925 2.13 / 241.24 23 60
3 13 1973.52 20 14.77 3110 919 3.05 / 242.16 6 62
4 13 1110.08 20 14.85 1954 580 3.63 / 242.74 6 78
5 13 804.36 20 14.89 1528 455 4.08 / 243.20 6 82
6 13 85.68 20 15.10 443 134 4.22 / 243.33 6 76
7 8 0.00 259 15.07 296 1155 5.37 / 244.49 6 132
Average= 5.09
(KJ/cycle)

Cycle 46 GMT 7/ 5/2020 8: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 29 15.08 457 200 0.20 / 234.05 6 28
2 7 2012.56 40 14.82 3165 1876 2.08 / 235.92 28 61
3 13 1985.04 20 14.79 3117 922 3.00 / 236.84 6 63
4 13 1104.88 20 14.86 1949 579 3.58 / 237.42 6 78
5 13 694.92 20 14.93 1365 408 3.98 / 237.83 6 82
6 13 30.84 20 15.13 351 106 4.09 / 237.94 6 72
7 8 0.12 264 15.08 296 1178 5.27 / 239.12 6 134
Average= 5.09
(KJ/cycle)

Cycle 45 GMT 27/ 4/2020 11: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 28 15.09 453 191 0.19 / 228.62 6 24
2 7 2003.24 40 14.83 3155 1872 2.06 / 230.49 24 59
3 13 1972.56 20 14.79 3122 923 2.99 / 231.41 6 64
4 13 1369.40 20 14.81 2288 678 3.66 / 232.09 6 76
5 13 854.80 20 14.90 1590 474 4.14 / 232.57 6 82
6 13 45.68 20 15.13 372 113 4.25 / 232.68 6 73
7 8 0.24 265 15.09 292 1168 5.42 / 233.85 6 133
Average= 5.08
(KJ/cycle)

Cycle 44 GMT 17/ 4/2020 14:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 28 15.10 460 194 0.19 / 223.19 6 25
2 10 1008.76 3 15.15 1841 84 0.28 / 223.28 6 48
3 3 930.48 -1 15.45 9 0 0.08 / 223.28 6 48
4 7 2013.88 41 14.82 3172 1927 2.21 / 225.20 48 59
5 13 1985.08 20 14.78 3132 926 3.13 / 226.13 6 63
6 13 1417.08 20 14.80 2375 703 3.83 / 226.83 6 75
7 13 490.88 20 15.01 1059 318 4.15 / 227.15 6 83
8 13 97.92 20 15.12 456 138 4.29 / 227.29 6 75
9 8 0.12 259 15.09 292 1141 5.43 / 228.43 6 136
Average= 5.08
(KJ/cycle)

Cycle 43 GMT 7/ 4/2020 17:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 28 15.10 461 195 0.19 / 218.04 6 30
2 7 2004.04 40 14.84 3153 1872 2.07 / 219.92 30 61
3 13 1974.92 20 14.79 3121 923 2.99 / 220.84 6 63
4 13 1198.28 20 14.86 2074 616 3.61 / 221.46 6 78
5 13 459.40 20 15.03 1018 306 3.91 / 221.76 6 83
6 8 0.16 278 15.11 294 1235 5.15 / 223.00 6 130
Average= 5.07
(KJ/cycle)

Cycle 42 GMT 28/ 3/2020 20:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 28 15.10 454 192 0.19 / 212.62 6 29
2 7 2014.20 41 14.83 3183 1935 2.13 / 214.55 6 62
3 13 1982.52 20 14.79 3122 923 3.05 / 215.48 6 64
4 13 1199.92 20 14.86 2079 618 3.67 / 216.09 6 79
5 13 786.60 20 14.94 1504 449 4.12 / 216.54 6 84
6 13 169.76 20 15.11 570 172 4.29 / 216.72 6 79
7 8 0.08 257 15.11 292 1134 5.42 / 217.85 6 133
Average= 5.07
(KJ/cycle)

Cycle 41 GMT 18/ 3/2020 23:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 28 15.11 459 194 0.19 / 207.23 6 31
2 7 2004.28 40 14.84 3159 1875 2.07 / 209.10 31 62
3 13 1870.36 20 14.81 2988 885 2.95 / 209.99 6 67
4 13 1246.80 20 14.86 2136 635 3.59 / 210.62 6 78
5 13 638.16 20 14.98 1285 385 3.97 / 211.01 6 84
6 13 308.56 20 15.07 792 239 4.21 / 211.25 6 83
7 8 0.08 265 15.10 295 1180 5.39 / 212.43 6 129
Average= 5.06
(KJ/cycle)

Cycle 40 GMT 9/ 3/2020 3: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 28 15.11 459 194 0.19 / 201.84 6 28
2 7 2010.64 41 14.83 3176 1931 2.13 / 203.77 28 60
3 13 1840.48 20 14.81 2961 877 3.00 / 204.65 6 69
4 13 1422.20 20 14.82 2390 708 3.71 / 205.36 6 77
5 13 721.36 20 14.96 1410 422 4.13 / 205.78 6 85
6 8 0.16 283 15.13 293 1255 5.39 / 207.03 6 136
Average= 5.05
(KJ/cycle)

Cycle 39 GMT 28/ 2/2020 6:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 28 15.13 454 192 0.19 / 196.42 6 31
2 7 2003.56 40 14.85 3169 1882 2.07 / 198.31 31 62
3 13 1767.68 20 14.83 2854 846 2.92 / 199.15 6 70
4 13 1627.32 20 14.78 2665 788 3.71 / 199.94 6 74
5 13 648.84 20 15.00 1302 391 4.10 / 200.33 6 85
6 13 115.20 20 15.15 490 148 4.25 / 200.48 6 76
7 8 0.00 264 15.13 292 1166 5.41 / 201.65 6 138
Average= 5.04
(KJ/cycle)

Cycle 38 GMT 18/ 2/2020 9:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 28 15.13 468 198 0.20 / 191.25 6 29
2 7 2002.76 40 14.85 3158 1876 2.07 / 193.13 6 62
3 13 1753.56 20 14.83 2852 846 2.92 / 193.97 6 71
4 13 1157.56 20 14.89 2017 601 3.52 / 194.58 6 79
5 13 748.24 20 14.97 1452 435 3.96 / 195.01 6 84
6 8 0.08 279 15.14 289 1221 5.18 / 196.23 6 133
Average= 5.03
(KJ/cycle)

Cycle 37 GMT 8/ 2/2020 12:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 28 15.14 453 192 0.19 / 185.92 6 30
2 7 2004.16 41 14.86 3165 1928 2.12 / 187.85 30 62
3 13 1663.44 20 14.84 2709 804 2.92 / 188.66 6 72
4 13 1447.92 20 14.83 2409 715 3.64 / 189.37 6 77
5 13 892.52 20 14.93 1652 493 4.13 / 189.86 6 84
6 8 0.20 272 15.15 289 1191 5.32 / 191.05 6 136
Average= 5.03
(KJ/cycle)

Cycle 36 GMT 29/ 1/2020 15:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 28 15.15 462 196 0.20 / 180.51 6 28
2 7 2006.48 40 14.86 3164 1881 2.08 / 182.39 6 61
3 13 1976.52 20 14.82 3126 927 3.00 / 183.32 6 64
4 13 1382.52 20 14.87 2319 690 3.69 / 184.01 6 76
5 13 917.20 20 14.94 1679 502 4.19 / 184.51 6 82
6 8 0.12 282 15.16 286 1223 5.42 / 185.73 6 135
Average= 5.02
(KJ/cycle)

Cycle 35 GMT 19/ 1/2020 18:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 28 15.16 458 194 0.19 / 175.20 6 29
2 7 2015.04 40 14.86 3187 1894 2.09 / 177.10 29 61
3 13 1990.04 20 14.81 3143 931 3.02 / 178.03 6 64
4 13 1325.20 20 14.88 2245 668 3.69 / 178.69 6 77
5 13 641.44 20 15.03 1295 389 4.08 / 179.08 6 84
6 8 -0.04 278 15.16 292 1231 5.31 / 180.31 6 142
Average= 5.01
(KJ/cycle)

Cycle 34 GMT 9/ 1/2020 21:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 28 15.16 454 193 0.19 / 169.73 6 29
2 7 2005.72 40 14.88 3157 1879 2.07 / 171.60 29 62
3 13 1975.84 20 14.83 3147 933 3.01 / 172.54 6 65
4 13 1375.84 20 14.88 2327 693 3.70 / 173.23 6 77
5 13 941.92 20 14.95 1720 514 4.21 / 173.74 6 82
6 13 37.92 20 15.20 368 112 4.32 / 173.86 6 71
7 8 0.16 257 15.17 295 1150 5.47 / 175.01 6 141
Average= 5.00
(KJ/cycle)

Cycle 33 GMT 31/12/2019 1: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 28 15.16 453 192 0.19 / 164.48 6 30
2 7 2010.44 40 14.87 3165 1883 2.07 / 166.37 30 62
3 13 1978.84 20 14.83 3122 926 3.00 / 167.29 6 66
4 13 1159.20 20 14.94 2014 602 3.60 / 167.90 6 81
5 13 702.24 20 15.03 1376 414 4.02 / 168.31 6 85
6 8 0.04 278 15.18 290 1224 5.24 / 169.53 6 132
Average= 4.99
(KJ/cycle)

Cycle 32 GMT 21/12/2019 3:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 28 15.16 458 194 0.19 / 159.20 6 30
2 7 2005.64 40 14.87 3169 1885 2.08 / 161.09 30 63
3 13 1799.16 20 14.86 2890 859 2.94 / 161.95 6 70
4 13 1399.80 20 14.88 2346 698 3.64 / 162.64 6 78
5 13 626.72 20 15.05 1271 383 4.02 / 163.03 6 85
6 13 62.00 20 15.20 404 123 4.14 / 163.15 6 77
7 8 0.24 257 15.17 293 1142 5.28 / 164.29 6 137
Average= 4.98
(KJ/cycle)

Cycle 31 GMT 11/12/2019 7: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 28 15.17 451 192 0.19 / 153.90 6 28
2 7 2004.88 40 14.88 3167 1885 2.08 / 155.78 28 63
3 13 1977.00 20 14.84 3121 926 3.00 / 156.71 6 66
4 13 1274.12 20 14.92 2168 647 3.65 / 157.35 6 78
5 13 730.60 20 15.03 1420 427 4.08 / 157.78 6 82
6 8 0.28 278 15.18 291 1228 5.30 / 159.01 6 140
Average= 4.97
(KJ/cycle)

Cycle 30 GMT 1/12/2019 10: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 28 15.18 459 195 0.20 / 148.55 6 28
2 10 1001.16 3 15.20 1825 83 0.28 / 148.63 6 51
3 3 918.08 -1 15.50 10 0 0.08 / 148.63 6 51
4 7 2010.68 40 14.88 3161 1881 2.16 / 150.51 51 63
5 13 1979.68 20 14.83 3140 931 3.09 / 151.44 6 67
6 13 1269.24 20 14.92 2169 647 3.74 / 152.09 6 81
7 13 740.52 20 15.03 1428 429 4.17 / 152.52 6 85
8 8 0.12 272 15.19 287 1186 5.35 / 153.70 6 130
Average= 4.96
(KJ/cycle)

Cycle 29 GMT 21/11/2019 13:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 28 15.18 460 196 0.20 / 143.33 6 25
2 7 2004.28 40 14.88 3172 1888 2.08 / 145.22 25 64
3 13 1973.32 20 14.85 3120 927 3.01 / 146.15 6 64
4 13 1075.88 20 14.98 1911 573 3.58 / 146.72 6 80
5 13 655.24 20 15.06 1314 396 3.98 / 147.12 6 85
6 13 34.88 20 15.23 358 109 4.09 / 147.22 6 73
7 8 0.12 253 15.19 293 1126 5.21 / 148.35 6 132
Average= 4.95
(KJ/cycle)

Cycle 28 GMT 11/11/2019 16:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 28 15.18 468 199 0.20 / 138.13 6 25
2 7 2005.08 40 14.89 3158 1881 2.08 / 140.01 25 64
3 13 1870.36 20 14.86 2994 890 2.97 / 140.90 6 70
4 13 1279.12 20 14.93 2186 653 3.62 / 141.55 6 81
5 13 512.32 20 15.11 1098 332 3.95 / 141.89 6 86
6 13 31.00 20 15.23 359 109 4.06 / 142.00 6 74
7 8 0.16 253 15.19 297 1141 5.20 / 143.14 6 129
Average= 4.94
(KJ/cycle)

Cycle 27 GMT 1/11/2019 19:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 28 15.19 446 190 0.19 / 132.57 6 24
2 7 2011.56 40 14.89 3180 1894 2.08 / 134.46 24 64
3 13 1979.72 20 14.85 3129 929 3.01 / 135.39 6 65
4 13 1673.64 20 14.85 2733 812 3.82 / 136.20 6 73
5 13 697.28 20 15.05 1385 417 4.24 / 136.62 6 84
6 13 34.72 20 15.24 371 113 4.35 / 136.73 6 73
7 8 -0.04 261 15.19 302 1197 5.55 / 137.93 6 130
Average= 4.93
(KJ/cycle)

Cycle 26 GMT 22/10/2019 22:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 28 15.20 465 198 0.20 / 127.52 6 23
2 7 2010.52 40 14.89 3175 1891 2.09 / 129.41 23 63
3 13 1685.00 20 14.90 2741 817 2.91 / 130.23 6 73
4 13 1048.20 20 14.99 1861 558 3.46 / 130.79 6 83
5 13 546.72 20 15.09 1152 348 3.81 / 131.14 6 85
6 13 31.56 20 15.24 351 107 3.92 / 131.24 6 74
7 8 0.16 255 15.20 293 1136 5.05 / 132.38 6 133
Average= 4.90
(KJ/cycle)

Cycle 25 GMT 13/10/2019 1:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 28 15.20 455 194 0.19 / 122.22 6 22
2 7 2013.52 41 14.89 3174 1938 2.13 / 124.15 6 63
3 13 1981.80 20 14.86 3155 938 3.07 / 125.09 6 67
4 13 1218.28 20 14.95 2106 630 3.70 / 125.72 6 82
5 13 563.28 20 15.10 1178 356 4.05 / 126.08 6 86
6 13 35.64 20 15.24 370 113 4.17 / 126.19 6 74
7 8 0.08 250 15.20 299 1136 5.30 / 127.33 6 133
Average= 4.90
(KJ/cycle)

Cycle 24 GMT 3/10/2019 4:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 28 15.20 458 195 0.19 / 116.99 6 23
2 7 2003.72 40 14.91 3170 1891 2.09 / 118.88 23 64
3 13 1970.84 20 14.86 3121 928 3.01 / 119.80 6 64
4 13 1214.52 20 14.97 2100 629 3.64 / 120.43 6 78
5 13 532.68 20 15.11 1134 343 3.98 / 120.78 6 84
6 13 28.72 20 15.25 351 107 4.09 / 120.88 6 73
7 8 0.08 253 15.21 296 1139 5.23 / 122.02 6 129
Average= 4.88
(KJ/cycle)

Cycle 23 GMT 23/ 9/2019 7:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 28 15.20 464 197 0.20 / 111.77 6 23
2 7 2004.92 40 14.91 3170 1891 2.09 / 113.66 23 64
3 13 1829.96 20 14.89 2935 874 2.96 / 114.53 6 69
4 13 1177.04 20 14.98 2051 614 3.58 / 115.15 6 80
5 13 610.44 20 15.09 1250 377 3.95 / 115.52 6 85
6 13 28.52 20 15.25 353 108 4.06 / 115.63 6 73
7 8 0.08 257 15.21 297 1161 5.22 / 116.79 6 135
Average= 4.87
(KJ/cycle)

Cycle 22 GMT 13/ 9/2019 10:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 28 15.21 454 193 0.19 / 106.43 6 22
2 7 2013.68 40 14.91 3173 1892 2.09 / 108.32 22 63
3 13 1984.64 20 14.87 3131 931 3.02 / 109.25 6 65
4 13 1330.92 20 14.94 2259 675 3.69 / 109.93 6 78
5 13 582.12 20 15.10 1197 361 4.05 / 110.29 6 84
6 13 23.52 20 15.25 347 106 4.16 / 110.40 6 75
7 8 0.08 257 15.21 300 1173 5.33 / 111.57 6 132
Average= 4.85
(KJ/cycle)

Cycle 21 GMT 3/ 9/2019 14: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 28 15.21 450 192 0.19 / 101.18 6 23
2 7 2012.56 40 14.92 3176 1895 2.09 / 103.07 23 63
3 13 1981.36 20 14.89 3126 931 3.02 / 104.00 6 63
4 13 1156.12 20 14.99 2015 604 3.62 / 104.61 6 78
5 13 545.32 20 15.12 1148 347 3.97 / 104.95 6 82
6 13 135.24 20 15.23 518 158 4.13 / 105.11 6 77
7 8 0.20 255 15.22 290 1126 5.25 / 106.24 6 132
Average= 4.83
(KJ/cycle)

Cycle 20 GMT 24/ 8/2019 17: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 28 15.22 460 196 0.20 / 95.98 6 22
2 7 2011.00 40 14.93 3171 1894 2.09 / 97.88 22 63
3 13 1841.64 20 14.90 2953 880 2.97 / 98.76 6 68
4 13 1208.32 20 14.99 2086 625 3.60 / 99.38 6 79
5 13 571.36 20 15.12 1192 360 3.96 / 99.74 6 85
6 13 42.48 20 15.26 368 112 4.07 / 99.86 6 74
7 8 0.04 255 15.22 291 1129 5.20 / 100.98 6 135
Average= 4.81
(KJ/cycle)

Cycle 19 GMT 14/ 8/2019 20: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 28 15.21 469 200 0.20 / 90.80 6 23
2 7 2004.24 40 14.93 3160 1887 2.09 / 92.68 23 63
3 13 1871.80 20 14.91 2984 890 2.98 / 93.57 6 69
4 13 1270.72 20 14.97 2173 651 3.63 / 94.22 6 79
5 13 446.24 20 15.16 1006 305 3.93 / 94.53 6 83
6 13 56.88 20 15.26 396 121 4.05 / 94.65 6 74
7 8 0.12 253 15.23 295 1137 5.19 / 95.79 6 132
Average= 4.79
(KJ/cycle)

Cycle 18 GMT 4/ 8/2019 23:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 28 15.21 453 193 0.19 / 85.38 6 25
2 7 2005.28 40 14.93 3172 1894 2.09 / 87.27 25 64
3 13 1975.32 20 14.90 3106 926 3.01 / 88.20 6 67
4 13 1267.44 20 14.99 2168 650 3.66 / 88.85 6 79
5 13 734.04 20 15.07 1435 433 4.10 / 89.28 6 87
6 13 157.56 20 15.23 555 169 4.26 / 89.45 6 79
7 8 0.16 255 15.22 296 1149 5.41 / 90.60 6 136
Average= 4.77
(KJ/cycle)

Cycle 17 GMT 26/ 7/2019 2:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 27 15.22 464 191 0.19 / 80.11 6 25
2 7 2011.36 40 14.93 3182 1900 2.09 / 82.01 25 65
3 13 1980.04 20 14.89 3150 938 3.03 / 82.95 6 68
4 13 1238.00 20 14.99 2130 639 3.67 / 83.59 6 80
5 13 526.04 20 15.14 1126 341 4.01 / 83.93 6 86
6 13 44.52 20 15.27 372 114 4.12 / 84.05 6 75
7 8 0.08 250 15.23 299 1138 5.26 / 85.18 6 136
Average= 4.73
(KJ/cycle)

Cycle 16 GMT 16/ 7/2019 5:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 28 15.22 456 194 0.19 / 74.72 6 28
2 7 2014.40 40 14.92 3216 1919 2.11 / 76.64 28 66
3 13 1986.88 20 14.90 3153 940 3.05 / 77.58 6 69
4 13 1156.16 20 15.01 2025 608 3.66 / 78.19 6 83
5 13 766.52 20 15.07 1482 447 4.11 / 78.64 6 88
6 13 54.36 20 15.26 397 121 4.23 / 78.76 6 78
7 8 0.12 253 15.23 303 1168 5.40 / 79.92 6 129
Average= 4.70
(KJ/cycle)

Cycle 15 GMT 6/ 7/2019 8:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 28 15.23 469 200 0.20 / 69.43 6 28
2 7 2013.92 40 14.94 3192 1908 2.11 / 71.34 28 66
3 13 1981.72 20 14.90 3159 941 3.05 / 72.28 6 69
4 13 1164.84 20 15.01 2048 615 3.66 / 72.89 6 83
5 13 633.84 20 15.11 1304 394 4.06 / 73.29 6 89
6 13 15.60 20 15.28 331 101 4.16 / 73.39 6 75
7 8 0.12 248 15.23 302 1141 5.30 / 74.53 6 135
Average= 4.66
(KJ/cycle)

Cycle 14 GMT 26/ 6/2019 11:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 28 15.23 478 204 0.20 / 63.99 6 29
2 7 2004.12 40 14.94 3182 1902 2.11 / 65.89 29 67
3 13 1974.48 20 14.91 3137 935 3.04 / 66.83 6 70
4 13 1260.32 20 14.99 2179 653 3.69 / 67.48 6 82
5 13 824.80 20 15.06 1579 476 4.17 / 67.96 6 89
6 8 0.00 270 15.24 309 1271 5.44 / 69.23 6 134
Average= 4.62
(KJ/cycle)

Cycle 13 GMT 16/ 6/2019 14:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 28 15.23 472 201 0.20 / 58.65 6 30
2 7 2006.32 40 14.95 3186 1905 2.11 / 60.55 30 67
3 13 1912.48 20 14.92 3050 910 3.02 / 61.46 6 72
4 13 1241.48 20 15.00 2159 648 3.66 / 62.11 6 83
5 13 560.12 20 15.14 1198 363 4.03 / 62.47 6 88
6 13 36.52 20 15.28 380 116 4.14 / 62.59 6 76
7 8 0.08 250 15.24 314 1196 5.34 / 63.79 6 130
Average= 4.56
(KJ/cycle)

Cycle 12 GMT 6/ 6/2019 17:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 27 15.23 475 195 0.20 / 53.60 6 32
2 7 2005.52 40 14.96 3175 1900 2.10 / 55.50 32 67
3 13 1709.64 20 14.96 2778 831 2.93 / 56.33 6 75
4 13 1061.68 20 15.04 1899 571 3.50 / 56.90 6 85
5 13 405.68 20 15.19 948 288 3.79 / 57.19 6 86
6 8 0.36 265 15.24 312 1260 5.05 / 58.45 6 130
Average= 4.50
(KJ/cycle)

Cycle 11 GMT 27/ 5/2019 20: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 27 15.24 481 198 0.20 / 48.36 6 31
2 7 2007.44 40 14.96 3185 1906 2.10 / 50.27 6 66
3 13 1916.80 20 14.93 3076 918 3.02 / 51.18 6 70
4 13 1139.56 20 15.03 2013 605 3.63 / 51.79 6 83
5 13 493.24 20 15.17 1091 331 3.96 / 52.12 6 86
6 8 0.12 270 15.25 311 1281 5.24 / 53.40 6 130
Average= 4.45
(KJ/cycle)

Cycle 10 GMT 17/ 5/2019 22:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 27 15.25 454 187 0.19 / 43.21 6 33
2 7 2002.60 40 14.97 3175 1901 2.09 / 45.11 33 66
3 13 1690.56 20 14.97 2762 827 2.92 / 45.94 6 75
4 13 1254.56 20 15.01 2175 653 3.57 / 46.59 6 82
5 13 451.84 20 15.18 1030 313 3.88 / 46.90 6 85
6 13 18.08 20 15.29 347 106 3.99 / 47.01 6 76
7 8 0.12 242 15.25 312 1151 5.14 / 48.16 6 132
Average= 4.38
(KJ/cycle)

Cycle 9 GMT 8/ 5/2019 1:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 27 15.24 478 197 0.20 / 37.98 6 32
2 7 2008.52 40 14.96 3191 1909 2.11 / 39.89 32 67
3 13 1910.80 20 14.94 3078 920 3.03 / 40.81 6 72
4 13 1255.92 20 15.01 2185 656 3.68 / 41.47 6 83
5 13 481.36 20 15.18 1079 328 4.01 / 41.79 6 87
6 8 0.08 261 15.26 309 1231 5.24 / 43.02 6 134
Average= 4.30
(KJ/cycle)

Cycle 8 GMT 28/ 4/2019 4:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 27 15.25 466 192 0.19 / 32.75 6 32
2 7 2009.36 40 14.97 3180 1904 2.10 / 34.65 32 67
3 13 1822.16 20 14.95 2952 883 2.98 / 35.53 6 75
4 13 1075.84 20 15.05 1929 581 3.56 / 36.11 6 86
5 13 716.28 20 15.11 1428 432 3.99 / 36.55 6 90
6 8 0.16 261 15.25 311 1238 5.23 / 37.78 6 130
Average= 4.20
(KJ/cycle)

Cycle 7 GMT 18/ 4/2019 6:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 27 15.25 486 200 0.20 / 27.67 6 35
2 7 2004.20 40 14.97 3190 1910 2.11 / 29.58 35 68
3 13 1692.00 20 14.98 2767 829 2.94 / 30.41 6 77
4 13 1138.56 20 15.04 2016 606 3.55 / 31.01 6 85
5 13 473.08 20 15.18 1060 322 3.87 / 31.33 6 90
6 8 0.16 259 15.26 309 1221 5.09 / 32.56 6 130
Average= 4.07
(KJ/cycle)

Cycle 6 GMT 8/ 4/2019 9:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 23 15.26 457 160 0.16 / 22.61 6 33
2 10 1016.40 4 15.24 1861 113 0.27 / 22.72 6 61
3 3 1036.80 1 15.28 1901 29 0.30 / 22.75 6 48
4 7 2008.16 40 14.97 3200 1916 2.22 / 24.67 48 67
5 13 1589.32 20 15.00 2633 790 3.01 / 25.46 6 79
6 13 1075.44 20 15.06 1923 579 3.59 / 26.04 6 85
7 13 294.72 20 15.24 770 235 3.82 / 26.27 6 86
8 8 0.08 263 15.27 298 1197 5.02 / 27.47 6 130
Average= 3.92
(KJ/cycle)

Cycle 5 GMT 29/ 3/2019 12:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 31 15.26 460 218 0.22 / 17.50 6 36
2 3 785.04 -3 15.57 10 0 0.00 / 17.50 6 36
3 7 2011.24 40 14.98 3193 1913 2.13 / 19.41 36 66
4 13 1918.08 20 14.96 3078 921 3.05 / 20.33 6 71
5 13 1244.68 20 15.02 2147 645 3.70 / 20.98 6 83
6 13 350.20 20 15.23 866 264 3.96 / 21.24 6 86
7 8 0.16 266 15.27 297 1206 5.17 / 22.45 6 133
Average= 3.74
(KJ/cycle)

Cycle 4 GMT 19/ 3/2019 14:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 26 15.27 463 184 0.18 / 13.06 6 34
2 7 1511.04 40 15.13 2526 1529 1.71 / 14.58 34 70
3 13 1425.60 20 15.11 2417 730 2.44 / 15.32 6 72
4 13 1096.72 20 15.11 1954 590 3.03 / 15.91 6 80
5 13 280.64 20 15.27 750 229 3.26 / 16.13 6 84
6 8 0.04 253 15.29 296 1145 4.41 / 17.28 6 130
Average= 3.46
(KJ/cycle)

Cycle 3 GMT 18/ 3/2019 4:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 25 15.27 462 176 0.18 / 8.55 6 35
2 3 1067.60 2 15.28 1955 60 0.24 / 8.61 6 66
3 7 1527.32 40 15.12 2556 1546 1.78 / 10.15 66 69
4 13 1459.96 20 15.10 2464 744 2.53 / 10.90 6 73
5 13 1121.64 20 15.10 2003 605 3.13 / 11.50 6 80
6 13 302.84 20 15.26 791 241 3.37 / 11.74 6 84
7 8 0.04 246 15.28 300 1128 4.50 / 12.87 6 133
Average= 3.22
(KJ/cycle)

Cycle 2 GMT 16/ 3/2019 18:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 31 15.29 457 217 0.22 / 4.32 6 36
2 3 771.88 -4 15.58 10 0 0.00 / 4.32 6 36
3 7 1504.24 40 15.13 2515 1522 1.74 / 5.84 36 69
4 13 1414.48 20 15.11 2403 726 2.46 / 6.57 6 74
5 13 891.40 20 15.14 1670 506 2.97 / 7.07 6 83
6 13 113.44 20 15.31 485 149 3.12 / 7.22 6 77
7 8 0.08 255 15.28 295 1149 4.27 / 8.37 6 132
Average= 2.79
(KJ/cycle)

Cycle 1 GMT 15/ 3/2019 8: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 31 15.48 435 209 0.21 / 1.67 6 28
2 3 738.44 -4 15.59 10 0 0.00 / 1.67 6 28
3 7 965.08 40 15.24 1774 1081 1.29 / 2.75 28 75
4 13 188.92 20 15.35 605 186 1.48 / 2.93 6 78
5 8 0.08 259 15.33 295 1171 2.65 / 4.10 6 130
Average= 2.05
(KJ/cycle)

Cycle 0 GMT 14/ 3/2019 21:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 55.28 30 15.63 360 169 0.17 / 0.17 6 30
2 7 64.36 40 15.61 365 228 0.40 / 0.40 30 34
3 8 -0.00 263 15.56 259 1060 1.46 / 1.46 6 136
Average= 1.46
(KJ/cycle)