SIO Argo Site:
Pump Diagnostics Page   



Serial= 8781 WMO= 4903024

Return

←PreviousNext→

Cycle 183 GMT 25/ 4/2024 11: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 32 15.09 501 242 0.24 / 778.36 2 2
2 3 1013.68 1 15.18 1799 27 0.27 / 778.38 2 5
3 7 2004.60 31 14.91 2957 1367 1.64 / 779.75 2 4
4 13 1612.48 18 14.89 2513 674 2.31 / 780.42 2 6
5 13 1061.24 18 14.92 1816 488 2.80 / 780.91 2 6
6 13 648.80 18 14.97 1276 344 3.14 / 781.25 2 7
7 13 227.84 18 15.08 687 186 3.33 / 781.44 2 4
8 8 0.12 165 15.11 332 828 4.16 / 782.27 2 3
Average= 4.25
(KJ/cycle)

Cycle 182 GMT 15/ 4/2024 15:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 32 15.08 483 233 0.23 / 774.19 2 3
2 7 2010.92 31 14.91 2968 1372 1.60 / 775.56 2 5
3 13 1604.24 18 14.89 2498 670 2.27 / 776.23 2 7
4 13 1182.92 18 14.90 1979 531 2.81 / 776.76 2 6
5 13 622.16 18 14.98 1245 336 3.14 / 777.10 2 7
6 13 218.52 18 15.08 677 184 3.32 / 777.28 2 5
7 8 0.00 165 15.11 334 833 4.16 / 778.11 2 5
Average= 4.25
(KJ/cycle)

Cycle 181 GMT 5/ 4/2024 20:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 32 15.08 493 238 0.24 / 770.05 2 3
2 7 2003.16 31 14.90 2959 1367 1.60 / 771.42 2 5
3 13 1612.36 18 14.89 2522 676 2.28 / 772.10 2 5
4 13 1064.16 18 14.92 1821 489 2.77 / 772.58 2 5
5 13 646.16 18 14.97 1282 345 3.12 / 772.93 2 7
6 13 223.56 18 15.08 686 186 3.30 / 773.12 2 6
7 8 0.16 165 15.11 337 840 4.14 / 773.96 2 9
Average= 4.25
(KJ/cycle)

Cycle 180 GMT 27/ 3/2024 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.52 32 15.08 518 250 0.25 / 765.82 2 2
2 7 2010.88 31 14.91 2972 1374 1.62 / 767.20 2 6
3 13 1747.60 18 14.88 2677 717 2.34 / 767.91 2 6
4 13 1191.60 18 14.90 1983 532 2.87 / 768.45 2 8
5 13 642.28 18 14.98 1273 343 3.22 / 768.79 2 7
6 13 224.92 18 15.09 685 186 3.40 / 768.97 2 4
7 8 0.20 165 15.11 337 840 4.24 / 769.81 2 3
Average= 4.25
(KJ/cycle)

Cycle 179 GMT 17/ 3/2024 5:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 32 15.08 508 245 0.25 / 761.63 2 3
2 7 2004.48 31 14.90 2961 1368 1.61 / 763.00 2 6
3 13 1604.16 18 14.89 2506 672 2.28 / 763.67 2 6
4 13 1185.04 18 14.90 1989 533 2.82 / 764.20 2 6
5 13 612.48 18 14.98 1243 335 3.15 / 764.54 2 7
6 13 191.92 18 15.09 650 177 3.33 / 764.71 2 4
7 8 -0.08 165 15.11 345 860 4.19 / 765.57 2 4
Average= 4.25
(KJ/cycle)

Cycle 178 GMT 7/ 3/2024 10:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 33 15.08 491 244 0.24 / 757.48 2 3
2 7 2010.64 31 14.90 2968 1371 1.62 / 758.85 2 5
3 13 1593.16 18 14.89 2492 668 2.28 / 759.52 2 8
4 13 1187.24 18 14.90 1975 530 2.81 / 760.05 2 7
5 13 608.00 18 14.98 1229 331 3.14 / 760.38 2 6
6 13 193.52 18 15.09 636 173 3.32 / 760.55 2 4
7 8 0.12 165 15.11 334 833 4.15 / 761.38 2 2
Average= 4.25
(KJ/cycle)

Cycle 177 GMT 26/ 2/2024 14:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.76 33 15.09 502 250 0.25 / 753.23 2 3
2 7 2005.32 31 14.92 2957 1368 1.62 / 754.60 2 6
3 13 1730.92 18 14.89 2651 711 2.33 / 755.31 2 6
4 13 1154.68 18 14.91 1930 518 2.85 / 755.83 2 8
5 13 720.60 18 14.97 1368 369 3.21 / 756.19 2 6
6 13 284.96 18 15.07 767 208 3.42 / 756.40 2 5
7 8 0.08 165 15.12 333 831 4.25 / 757.23 2 5
Average= 4.25
(KJ/cycle)

Cycle 176 GMT 16/ 2/2024 19:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.28 32 15.09 491 237 0.24 / 749.02 2 2
2 7 2004.48 31 14.90 2967 1370 1.61 / 750.39 2 6
3 13 1612.60 18 14.90 2519 676 2.28 / 751.07 2 5
4 13 1189.40 18 14.90 1984 532 2.82 / 751.60 2 6
5 13 749.96 18 14.95 1413 380 3.20 / 751.98 2 7
6 13 195.68 18 15.10 637 173 3.37 / 752.15 2 5
7 8 0.20 165 15.12 331 826 4.19 / 752.98 2 2
Average= 4.25
(KJ/cycle)

Cycle 175 GMT 7/ 2/2024 0:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 32 15.09 487 235 0.24 / 744.88 2 2
2 7 2005.48 31 14.90 2963 1369 1.60 / 746.25 2 5
3 13 1610.28 18 14.89 2517 675 2.28 / 746.92 2 6
4 13 1173.08 18 14.90 1964 527 2.81 / 747.45 2 8
5 13 616.12 18 14.99 1234 333 3.14 / 747.78 2 6
6 13 208.16 18 15.09 655 178 3.32 / 747.96 2 5
7 8 0.08 165 15.12 331 826 4.14 / 748.79 2 4
Average= 4.25
(KJ/cycle)

Cycle 174 GMT 28/ 1/2024 5:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 32 15.09 477 230 0.23 / 740.49 2 3
2 7 2005.28 31 14.91 2955 1366 1.60 / 741.85 2 6
3 13 1731.28 18 14.89 2663 714 2.31 / 742.57 2 6
4 13 1149.12 18 14.91 1923 516 2.83 / 743.08 2 6
5 13 709.12 18 14.97 1357 366 3.19 / 743.45 2 6
6 13 261.60 18 15.08 735 200 3.39 / 743.65 2 6
7 8 0.16 165 15.12 337 841 4.23 / 744.49 2 3
8 14 0.16 30 15.09 339 153 4.39 / 744.64 2 3
Average= 4.26
(KJ/cycle)

Cycle 173 GMT 18/ 1/2024 7:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 32 15.08 485 234 0.23 / 736.03 2 2
2 7 2003.56 31 14.91 2977 1376 1.61 / 737.41 2 5
3 13 1617.52 18 14.90 2523 677 2.29 / 738.08 2 6
4 13 1202.32 18 14.90 1999 536 2.82 / 738.62 2 9
5 13 650.32 18 14.99 1281 346 3.17 / 738.96 2 7
6 13 239.68 18 15.08 715 194 3.36 / 739.16 2 4
7 13 46.88 18 15.14 394 107 3.47 / 739.27 2 2
8 8 -0.04 165 15.11 337 840 4.31 / 740.11 2 5
9 14 -0.04 30 15.08 338 153 4.46 / 740.26 2 9
Average= 4.25
(KJ/cycle)

Cycle 172 GMT 8/ 1/2024 9:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 32 15.09 484 234 0.23 / 731.76 2 2
2 7 2002.64 31 14.91 2970 1373 1.61 / 733.13 2 5
3 13 1724.68 18 14.89 2653 711 2.32 / 733.84 2 4
4 13 1130.24 18 14.92 1916 515 2.83 / 734.36 2 5
5 13 583.56 18 15.00 1200 324 3.16 / 734.68 2 6
6 13 173.28 18 15.10 615 167 3.32 / 734.85 2 4
7 13 37.64 18 15.14 391 107 3.43 / 734.95 2 3
8 8 0.04 165 15.11 337 840 4.27 / 735.80 2 7
Average= 4.25
(KJ/cycle)

Cycle 171 GMT 29/12/2023 11:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 32 15.09 477 230 0.23 / 727.57 2 3
2 7 2009.44 31 14.90 2982 1377 1.61 / 728.94 2 5
3 13 1607.76 18 14.89 2519 675 2.28 / 729.62 2 6
4 13 1169.80 18 14.90 1958 525 2.81 / 730.14 2 7
5 13 719.08 18 14.96 1377 371 3.18 / 730.51 2 6
6 13 159.96 18 15.11 597 162 3.34 / 730.68 2 7
7 8 0.00 165 15.12 340 848 4.19 / 731.53 2 12
Average= 4.25
(KJ/cycle)

Cycle 170 GMT 19/12/2023 13:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 32 15.09 482 233 0.23 / 723.34 2 2
2 7 2008.76 31 14.91 2965 1370 1.60 / 724.71 2 5
3 13 1610.04 18 14.90 2510 673 2.28 / 725.38 2 6
4 13 1060.28 18 14.92 1813 487 2.76 / 725.87 2 7
5 13 643.48 18 14.98 1277 344 3.11 / 726.21 2 5
6 13 221.28 18 15.09 685 186 3.29 / 726.40 2 4
7 13 26.12 18 15.14 374 102 3.40 / 726.50 2 2
8 8 0.08 165 15.11 335 835 4.23 / 727.34 2 3
Average= 4.25
(KJ/cycle)

Cycle 169 GMT 9/12/2023 16: 2:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 32 15.10 474 229 0.23 / 718.96 2 3
2 7 2005.20 31 14.92 2976 1376 1.61 / 720.34 2 5
3 13 1734.60 18 14.89 2663 714 2.32 / 721.05 2 6
4 13 1155.52 18 14.91 1944 522 2.84 / 721.57 2 6
5 13 727.68 18 14.97 1390 375 3.22 / 721.95 2 7
6 13 301.16 18 15.07 796 216 3.43 / 722.16 2 5
7 13 37.60 18 15.14 382 104 3.54 / 722.27 2 3
8 8 0.00 165 15.11 336 838 4.37 / 723.10 2 4
Average= 4.25
(KJ/cycle)

Cycle 168 GMT 29/11/2023 18:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 32 15.09 477 230 0.23 / 714.62 2 3
2 7 2002.76 31 14.92 2964 1371 1.60 / 715.99 2 6
3 13 1728.96 18 14.89 2658 712 2.31 / 716.70 2 6
4 13 1166.04 18 14.91 1957 525 2.84 / 717.23 2 6
5 13 723.68 18 14.97 1385 373 3.21 / 717.60 2 6
6 13 284.64 18 15.08 768 208 3.42 / 717.81 2 5
7 13 67.32 18 15.13 435 118 3.54 / 717.93 2 3
8 8 0.00 165 15.12 323 806 4.34 / 718.73 2 3
Average= 4.25
(KJ/cycle)

Cycle 167 GMT 19/11/2023 20:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 32 15.09 482 233 0.23 / 710.18 2 3
2 7 2004.52 31 14.92 2953 1366 1.60 / 711.54 2 5
3 13 1734.32 18 14.89 2660 713 2.31 / 712.26 2 7
4 13 1150.64 18 14.92 1925 517 2.83 / 712.77 2 7
5 13 727.12 18 14.97 1383 373 3.20 / 713.14 2 7
6 13 288.64 18 15.08 774 210 3.41 / 713.35 2 6
7 13 61.16 18 15.14 416 113 3.52 / 713.47 2 3
8 13 17.96 18 15.14 361 98 3.62 / 713.57 2 3
9 8 0.12 165 15.11 329 820 4.44 / 714.39 2 2
Average= 4.25
(KJ/cycle)

Cycle 166 GMT 9/11/2023 22:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 32 15.10 474 229 0.23 / 705.90 2 3
2 7 2009.24 32 14.91 2963 1414 1.64 / 707.31 2 7
3 13 1610.96 18 14.90 2514 674 2.32 / 707.99 2 5
4 13 1058.68 18 14.93 1817 488 2.81 / 708.48 2 5
5 13 650.04 18 14.98 1291 348 3.15 / 708.82 2 6
6 13 223.76 18 15.09 677 184 3.34 / 709.01 2 4
7 13 44.40 18 15.14 385 105 3.44 / 709.11 2 2
8 8 0.04 165 15.12 333 831 4.27 / 709.94 2 8
Average= 4.25
(KJ/cycle)

Cycle 165 GMT 31/10/2023 0:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 32 15.10 477 230 0.23 / 701.60 2 2
2 7 2003.92 31 14.92 2960 1369 1.60 / 702.97 2 6
3 13 1609.68 18 14.91 2500 671 2.27 / 703.64 2 6
4 13 1180.88 18 14.91 1972 529 2.80 / 704.17 2 7
5 13 737.96 18 14.97 1400 377 3.18 / 704.55 2 7
6 13 296.96 18 15.07 793 215 3.39 / 704.76 2 5
7 13 43.04 18 15.14 388 106 3.50 / 704.87 2 3
8 8 0.00 165 15.12 322 803 4.30 / 705.67 2 8
Average= 4.25
(KJ/cycle)

Cycle 164 GMT 21/10/2023 3:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 33 15.09 480 239 0.24 / 697.29 2 3
2 7 2005.36 31 14.92 2962 1370 1.61 / 698.66 2 6
3 13 1736.64 18 14.90 2656 712 2.32 / 699.38 2 5
4 13 1159.40 18 14.92 1943 522 2.84 / 699.90 2 6
5 13 731.96 18 14.97 1392 375 3.22 / 700.27 2 5
6 13 191.64 18 15.11 630 171 3.39 / 700.45 2 4
7 13 44.44 18 15.15 386 105 3.49 / 700.55 2 2
8 8 0.12 165 15.13 328 819 4.31 / 701.37 2 8
Average= 4.25
(KJ/cycle)

Cycle 163 GMT 11/10/2023 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 33 15.10 477 238 0.24 / 692.95 2 3
2 7 2010.72 31 14.91 2971 1373 1.61 / 694.33 2 6
3 13 1609.68 18 14.90 2509 673 2.28 / 695.00 2 6
4 13 1191.08 18 14.91 1988 534 2.82 / 695.53 2 8
5 13 745.96 18 14.96 1416 381 3.20 / 695.91 2 8
6 13 299.80 18 15.07 796 216 3.41 / 696.13 2 5
7 13 41.44 18 15.15 386 105 3.52 / 696.23 2 2
8 8 0.16 165 15.12 329 821 4.34 / 697.06 2 5
Average= 4.25
(KJ/cycle)

Cycle 162 GMT 1/10/2023 7:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 33 15.11 473 236 0.24 / 688.69 2 3
2 7 2010.56 31 14.91 2968 1372 1.61 / 690.06 2 4
3 13 1613.52 18 14.90 2517 675 2.28 / 690.74 2 6
4 13 1170.68 18 14.91 1956 525 2.81 / 691.26 2 7
5 13 613.16 18 15.00 1235 333 3.14 / 691.59 2 6
6 13 209.56 18 15.11 656 178 3.32 / 691.77 2 5
7 13 52.08 18 15.15 405 110 3.43 / 691.88 2 3
8 8 0.08 165 15.13 333 831 4.26 / 692.72 2 5
Average= 4.25
(KJ/cycle)

Cycle 161 GMT 21/ 9/2023 9:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 33 15.12 459 229 0.23 / 684.33 2 3
2 7 2002.72 32 14.91 2962 1413 1.64 / 685.74 2 5
3 13 1606.80 18 14.90 2504 672 2.31 / 686.41 2 5
4 13 1173.76 18 14.91 1973 530 2.84 / 686.94 2 7
5 13 731.32 18 14.97 1397 376 3.22 / 687.32 2 6
6 13 281.00 18 15.08 759 206 3.43 / 687.53 2 4
7 13 63.00 18 15.14 425 116 3.54 / 687.64 2 3
8 8 0.08 165 15.13 325 811 4.35 / 688.45 2 4
Average= 4.25
(KJ/cycle)

Cycle 160 GMT 11/ 9/2023 11:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 32 15.11 472 228 0.23 / 680.06 2 3
2 3 1014.32 1 15.22 1793 27 0.26 / 680.09 2 4
3 7 2002.72 32 14.92 2964 1415 1.67 / 681.51 2 4
4 13 1601.16 18 14.91 2501 671 2.34 / 682.18 2 6
5 13 1056.16 18 14.93 1810 486 2.83 / 682.66 2 6
6 13 654.64 18 14.99 1287 347 3.18 / 683.01 2 6
7 13 236.52 18 15.10 690 188 3.36 / 683.20 2 5
8 13 32.88 18 15.16 368 100 3.46 / 683.30 2 3
9 8 0.32 165 15.14 321 802 4.27 / 684.10 2 4
Average= 4.25
(KJ/cycle)

Cycle 159 GMT 1/ 9/2023 13:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 32 15.10 483 233 0.23 / 675.81 2 3
2 7 2010.20 32 14.91 2970 1417 1.65 / 677.23 2 7
3 13 1590.56 18 14.90 2493 669 2.32 / 677.90 2 7
4 13 1048.20 18 14.94 1801 484 2.80 / 678.38 2 7
5 13 633.48 18 15.00 1259 340 3.14 / 678.72 2 5
6 13 225.20 18 15.10 683 186 3.33 / 678.91 2 3
7 13 55.28 18 15.15 411 112 3.44 / 679.02 2 3
8 8 0.12 165 15.13 327 816 4.26 / 679.84 2 3
Average= 4.25
(KJ/cycle)

Cycle 158 GMT 22/ 8/2023 16: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 32 15.10 478 231 0.23 / 671.59 2 3
2 7 2004.00 31 14.92 2963 1370 1.60 / 672.96 2 7
3 13 1603.36 18 14.91 2501 671 2.27 / 673.63 2 7
4 13 1055.00 18 14.94 1795 483 2.76 / 674.11 2 7
5 13 641.20 18 15.00 1273 344 3.10 / 674.45 2 6
6 13 221.16 18 15.11 674 183 3.28 / 674.64 2 4
7 13 43.48 18 15.15 389 106 3.39 / 674.74 2 3
8 8 0.00 165 15.13 334 834 4.22 / 675.58 2 3
Average= 4.25
(KJ/cycle)

Cycle 157 GMT 12/ 8/2023 18: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 33 15.10 478 238 0.24 / 667.36 2 2
2 7 2004.84 31 14.92 2955 1367 1.60 / 668.73 2 3
3 13 1608.00 18 14.91 2514 675 2.28 / 669.40 2 5
4 13 1074.64 18 14.93 1836 493 2.77 / 669.89 2 6
5 13 647.36 18 14.99 1291 348 3.12 / 670.24 2 6
6 13 219.60 18 15.11 680 185 3.31 / 670.43 2 5
7 13 27.32 18 15.16 375 102 3.41 / 670.53 2 3
8 8 0.12 165 15.13 331 826 4.23 / 671.36 2 6
Average= 4.25
(KJ/cycle)

Cycle 156 GMT 2/ 8/2023 20:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.48 32 15.11 494 239 0.24 / 662.97 2 3
2 3 1020.52 1 15.20 1827 28 0.27 / 662.99 2 5
3 7 2008.92 31 14.93 2964 1372 1.64 / 664.37 2 5
4 13 1731.36 18 14.91 2656 713 2.35 / 665.08 2 7
5 13 1154.64 18 14.93 1933 519 2.87 / 665.60 2 8
6 13 719.44 18 14.99 1377 372 3.24 / 665.97 2 5
7 13 284.04 18 15.09 777 211 3.45 / 666.18 2 5
8 13 30.52 18 15.16 381 104 3.56 / 666.28 2 2
9 8 0.12 165 15.13 335 836 4.39 / 667.12 2 4
Average= 4.25
(KJ/cycle)

Cycle 155 GMT 23/ 7/2023 22:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 33 15.11 483 241 0.24 / 658.68 2 3
2 3 979.28 -1 15.49 12 0 0.00 / 658.68 2 3
3 7 2005.84 31 14.93 2962 1371 1.61 / 660.05 2 5
4 13 1733.08 18 14.91 2664 715 2.33 / 660.76 2 6
5 13 1155.40 18 14.93 1943 522 2.85 / 661.28 2 9
6 13 618.84 18 15.01 1244 336 3.18 / 661.62 2 6
7 13 216.36 18 15.11 673 183 3.37 / 661.80 2 4
8 13 24.48 18 15.16 372 102 3.47 / 661.91 2 3
9 8 0.12 165 15.14 329 822 4.29 / 662.73 2 3
Average= 4.25
(KJ/cycle)

Cycle 154 GMT 14/ 7/2023 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.12 33 15.10 495 247 0.25 / 654.38 2 3
2 7 2008.76 32 14.92 2965 1416 1.66 / 655.79 2 3
3 13 1609.36 18 14.91 2508 673 2.34 / 656.46 2 6
4 13 1174.60 18 14.93 1964 528 2.86 / 656.99 2 8
5 13 617.84 18 15.01 1235 334 3.20 / 657.33 2 7
6 13 201.64 18 15.12 647 176 3.37 / 657.50 2 4
7 13 18.88 18 15.16 366 100 3.47 / 657.60 2 2
8 8 0.00 165 15.13 334 834 4.31 / 658.44 2 5
Average= 4.25
(KJ/cycle)

Cycle 153 GMT 4/ 7/2023 2:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 33 15.10 494 246 0.25 / 649.97 2 3
2 7 2012.28 31 14.92 2986 1381 1.63 / 651.35 2 3
3 13 1623.60 18 14.91 2522 677 2.30 / 652.03 2 5
4 13 1220.84 18 14.91 2028 544 2.85 / 652.57 2 8
5 13 766.92 18 14.97 1437 387 3.24 / 652.96 2 7
6 13 321.24 18 15.08 824 224 3.46 / 653.18 2 6
7 13 15.84 18 15.16 372 102 3.56 / 653.28 2 3
8 8 0.12 165 15.13 339 846 4.41 / 654.13 2 7
Average= 4.25
(KJ/cycle)

Cycle 152 GMT 24/ 6/2023 5: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 32 15.11 489 236 0.24 / 645.62 2 2
2 7 2012.24 31 14.92 2973 1375 1.61 / 647.00 2 5
3 13 1602.92 18 14.92 2516 676 2.29 / 647.67 2 5
4 13 1162.96 18 14.93 1949 524 2.81 / 648.19 2 7
5 13 721.52 18 14.99 1380 372 3.18 / 648.57 2 7
6 13 269.28 18 15.10 755 205 3.39 / 648.77 2 5
7 13 23.76 18 15.16 379 103 3.49 / 648.88 2 3
8 8 0.12 165 15.13 339 846 4.34 / 649.72 2 10
Average= 4.25
(KJ/cycle)

Cycle 151 GMT 14/ 6/2023 7:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.40 32 15.12 494 239 0.24 / 641.26 2 3
2 3 1027.76 1 15.19 1820 28 0.27 / 641.29 2 4
3 7 2006.08 31 14.92 2972 1375 1.64 / 642.67 2 6
4 13 1727.92 18 14.90 2654 712 2.35 / 643.38 2 5
5 13 1160.68 18 14.93 1959 526 2.88 / 643.90 2 6
6 13 722.00 18 14.99 1383 373 3.25 / 644.28 2 8
7 13 170.96 18 15.13 609 166 3.42 / 644.44 2 4
8 13 17.36 18 15.17 365 100 3.52 / 644.54 2 3
9 8 0.04 165 15.14 337 842 4.36 / 645.38 2 6
Average= 4.25
(KJ/cycle)

Cycle 150 GMT 4/ 6/2023 9:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 32 15.11 473 229 0.23 / 637.09 2 3
2 7 2005.72 31 14.93 2960 1370 1.60 / 638.46 2 6
3 13 1608.84 18 14.91 2515 675 2.27 / 639.14 2 6
4 13 1188.68 18 14.93 1983 533 2.81 / 639.67 2 6
5 13 637.48 18 15.01 1268 343 3.15 / 640.01 2 6
6 13 228.24 18 15.12 684 186 3.34 / 640.20 2 4
7 8 0.08 165 15.15 330 825 4.16 / 641.02 2 3
Average= 4.25
(KJ/cycle)

Cycle 149 GMT 25/ 5/2023 11:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 32 15.11 502 243 0.24 / 632.97 2 2
2 7 2007.96 31 14.92 2972 1375 1.62 / 634.34 2 5
3 13 1587.96 18 14.92 2488 668 2.29 / 635.01 2 6
4 13 1050.92 18 14.95 1805 486 2.77 / 635.50 2 7
5 13 634.36 18 15.01 1269 343 3.11 / 635.84 2 6
6 13 217.80 18 15.12 678 185 3.30 / 636.02 2 4
7 8 0.12 165 15.14 336 839 4.14 / 636.86 2 5
Average= 4.25
(KJ/cycle)

Cycle 148 GMT 15/ 5/2023 13:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.68 32 15.10 527 255 0.25 / 628.74 2 3
2 3 1012.88 1 15.22 1803 27 0.28 / 628.77 2 4
3 7 2007.56 31 14.93 2966 1373 1.65 / 630.14 2 5
4 13 1603.44 18 14.92 2507 673 2.33 / 630.81 2 5
5 13 1193.76 18 14.92 1998 537 2.86 / 631.35 2 5
6 13 639.64 18 15.01 1269 343 3.21 / 631.69 2 6
7 13 231.60 18 15.12 687 187 3.39 / 631.88 2 5
8 8 0.12 165 15.14 338 844 4.24 / 632.73 2 4
Average= 4.25
(KJ/cycle)

Cycle 147 GMT 5/ 5/2023 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 33 15.11 495 247 0.25 / 624.40 2 3
2 3 979.12 -1 15.48 11 0 0.00 / 624.40 2 3
3 3 1021.96 1 15.23 1808 28 0.27 / 624.43 2 5
4 7 2003.56 31 14.94 2971 1376 1.65 / 625.81 2 5
5 13 1748.56 18 14.91 2680 719 2.37 / 626.53 2 5
6 13 1153.40 18 14.94 1938 521 2.89 / 627.05 2 6
7 13 727.96 18 14.99 1396 377 3.27 / 627.42 2 7
8 13 276.56 18 15.10 764 208 3.48 / 627.63 2 4
9 8 0.00 165 15.14 342 854 4.33 / 628.49 2 2
Average= 4.25
(KJ/cycle)

Cycle 146 GMT 25/ 4/2023 17:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 33 15.12 497 248 0.25 / 620.15 2 2
2 7 2009.72 31 14.93 2969 1374 1.62 / 621.52 2 5
3 13 1730.40 18 14.91 2657 713 2.34 / 622.23 2 5
4 13 1159.80 18 14.94 1949 524 2.86 / 622.76 2 5
5 13 737.20 18 14.99 1405 379 3.24 / 623.14 2 6
6 13 182.72 18 15.14 626 171 3.41 / 623.31 2 4
7 8 0.20 165 15.15 340 850 4.26 / 624.16 2 2
Average= 4.25
(KJ/cycle)

Cycle 145 GMT 15/ 4/2023 20: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.52 32 15.12 502 243 0.24 / 615.89 2 3
2 7 2008.36 31 14.93 2965 1372 1.62 / 617.26 2 5
3 13 1608.00 18 14.92 2518 676 2.29 / 617.94 2 5
4 13 1189.64 18 14.93 1988 534 2.83 / 618.47 2 7
5 13 742.64 18 14.99 1402 378 3.20 / 618.85 2 6
6 13 303.64 18 15.10 794 216 3.42 / 619.07 2 5
7 8 0.12 165 15.15 332 830 4.25 / 619.90 2 7
Average= 4.25
(KJ/cycle)

Cycle 144 GMT 5/ 4/2023 22:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.76 32 15.11 516 249 0.25 / 611.67 2 3
2 7 2003.80 31 14.94 2974 1377 1.63 / 613.05 2 4
3 13 1728.72 18 14.91 2671 717 2.34 / 613.76 2 4
4 13 1142.16 18 14.94 1930 519 2.86 / 614.28 2 5
5 13 630.88 18 15.02 1261 341 3.20 / 614.62 2 6
6 13 227.08 18 15.13 688 187 3.39 / 614.81 2 4
7 8 0.04 165 15.15 335 837 4.23 / 615.65 2 2
Average= 4.25
(KJ/cycle)

Cycle 143 GMT 27/ 3/2023 0:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 32 15.12 529 256 0.26 / 607.38 2 3
2 7 2003.08 31 14.93 2964 1372 1.63 / 608.75 2 3
3 13 1607.60 18 14.92 2513 675 2.30 / 609.42 2 5
4 13 1321.28 18 14.91 2152 578 2.88 / 610.00 2 4
5 13 708.28 18 15.00 1366 369 3.25 / 610.37 2 6
6 13 275.12 18 15.11 760 207 3.46 / 610.58 2 5
7 8 0.24 165 15.15 338 845 4.30 / 611.42 2 3
Average= 4.25
(KJ/cycle)

Cycle 142 GMT 17/ 3/2023 2:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.00 32 15.13 496 240 0.24 / 603.08 2 3
2 7 2005.36 31 14.94 2966 1374 1.61 / 604.45 2 3
3 13 1731.28 18 14.91 2666 716 2.33 / 605.16 2 4
4 13 1279.44 18 14.92 2089 561 2.89 / 605.73 2 5
5 13 667.52 18 15.02 1314 355 3.25 / 606.08 2 6
6 13 250.84 18 15.12 721 196 3.44 / 606.28 2 4
7 8 0.04 165 15.15 337 842 4.28 / 607.12 2 3
Average= 4.25
(KJ/cycle)

Cycle 141 GMT 7/ 3/2023 4:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 32 15.13 491 238 0.24 / 598.93 2 2
2 3 1029.76 1 15.21 1834 28 0.27 / 598.95 2 3
3 7 2008.96 31 14.93 2963 1371 1.64 / 600.32 2 4
4 13 1606.48 18 14.92 2516 676 2.31 / 601.00 2 5
5 13 1039.92 18 14.96 1789 482 2.79 / 601.48 2 5
6 13 628.40 18 15.02 1257 340 3.13 / 601.82 2 6
7 13 209.08 18 15.13 656 179 3.31 / 602.00 2 4
8 8 0.08 165 15.15 334 835 4.15 / 602.84 2 2
Average= 4.25
(KJ/cycle)

Cycle 140 GMT 25/ 2/2023 6:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 32 15.12 487 236 0.24 / 594.55 2 2
2 7 2007.16 31 14.94 2974 1377 1.61 / 595.92 2 4
3 13 1593.52 18 14.93 2489 669 2.28 / 596.59 2 5
4 13 1163.20 18 14.94 1945 523 2.80 / 597.12 2 6
5 13 718.52 18 15.00 1380 373 3.18 / 597.49 2 6
6 13 275.08 18 15.11 759 206 3.38 / 597.69 2 5
7 8 0.08 165 15.15 336 840 4.22 / 598.53 2 3
8 14 0.08 30 15.13 338 153 4.38 / 598.69 2 4
Average= 4.25
(KJ/cycle)

Cycle 139 GMT 15/ 2/2023 8:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.60 32 15.12 507 245 0.25 / 590.25 2 3
2 7 2010.28 31 14.94 2972 1376 1.62 / 591.63 2 3
3 13 1732.36 18 14.91 2669 716 2.34 / 592.35 2 5
4 13 1173.24 18 14.94 1968 529 2.87 / 592.88 2 7
5 13 732.76 18 15.00 1401 378 3.25 / 593.25 2 6
6 13 286.72 18 15.11 785 214 3.46 / 593.47 2 5
7 8 0.16 165 15.15 337 842 4.30 / 594.31 2 3
Average= 4.25
(KJ/cycle)

Cycle 138 GMT 5/ 2/2023 11:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.12 32 15.12 514 249 0.25 / 586.02 2 2
2 3 1020.56 1 15.22 1821 28 0.28 / 586.05 2 5
3 7 2003.28 31 14.94 2963 1372 1.65 / 587.42 2 4
4 13 1730.08 18 14.91 2650 711 2.36 / 588.13 2 5
5 13 1154.88 18 14.94 1948 524 2.88 / 588.66 2 5
6 13 608.88 18 15.03 1238 335 3.22 / 588.99 2 6
7 13 198.28 18 15.14 647 176 3.40 / 589.17 2 4
8 8 0.04 165 15.16 336 840 4.24 / 590.01 2 3
Average= 4.24
(KJ/cycle)

Cycle 137 GMT 26/ 1/2023 13:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 32 15.13 498 241 0.24 / 581.86 2 3
2 7 2003.92 31 14.94 2965 1373 1.61 / 583.23 2 4
3 13 1603.36 18 14.92 2505 673 2.29 / 583.90 2 6
4 13 1046.84 18 14.96 1806 486 2.77 / 584.39 2 6
5 13 637.20 18 15.02 1275 345 3.12 / 584.73 2 5
6 13 215.16 18 15.13 678 185 3.30 / 584.92 2 4
7 8 -0.04 165 15.15 342 855 4.16 / 585.77 2 7
Average= 4.24
(KJ/cycle)

Cycle 136 GMT 16/ 1/2023 15:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 32 15.13 491 238 0.24 / 577.61 2 2
2 3 976.80 -1 15.49 12 0 0.00 / 577.61 2 2
3 3 1023.60 1 15.23 1811 28 0.27 / 577.64 2 4
4 7 2009.44 31 14.93 2968 1374 1.64 / 579.01 2 4
5 13 1729.48 18 14.92 2658 714 2.35 / 579.73 2 5
6 13 1127.12 18 14.95 1909 514 2.87 / 580.24 2 7
7 13 699.72 18 15.01 1352 365 3.23 / 580.61 2 6
8 13 145.44 18 15.16 577 157 3.39 / 580.76 2 6
9 8 0.20 165 15.16 340 850 4.24 / 581.62 2 4
Average= 4.25
(KJ/cycle)

Cycle 135 GMT 6/ 1/2023 17:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.16 32 15.13 506 245 0.24 / 573.39 2 3
2 3 1025.00 1 15.21 1808 27 0.27 / 573.42 2 4
3 7 2003.24 31 14.94 2956 1369 1.64 / 574.79 2 5
4 13 1596.72 18 14.93 2494 670 2.31 / 575.46 2 4
5 13 1163.72 18 14.94 1952 525 2.84 / 575.99 2 6
6 13 725.04 18 15.00 1390 375 3.21 / 576.36 2 6
7 13 173.40 18 15.15 611 167 3.38 / 576.53 2 5
8 8 0.08 165 15.16 339 848 4.23 / 577.38 2 3
Average= 4.25
(KJ/cycle)

Cycle 134 GMT 27/12/2022 20: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 33 15.13 498 249 0.25 / 569.01 2 2
2 3 977.00 -1 15.49 12 0 0.00 / 569.01 2 2
3 7 2012.48 32 14.93 2972 1420 1.67 / 570.43 2 4
4 13 1606.88 18 14.92 2511 674 2.34 / 571.11 2 5
5 13 1174.28 18 14.94 1963 528 2.87 / 571.64 2 5
6 13 613.84 18 15.03 1239 335 3.21 / 571.97 2 6
7 13 198.88 18 15.14 641 175 3.38 / 572.15 2 4
8 8 -0.04 165 15.16 339 848 4.23 / 572.99 2 2
9 14 -0.04 30 15.14 342 155 4.38 / 573.15 2 3
Average= 4.25
(KJ/cycle)

Cycle 133 GMT 17/12/2022 22:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.04 32 15.12 506 245 0.24 / 564.72 2 3
2 3 1019.56 1 15.22 1826 28 0.27 / 564.75 2 3
3 7 2003.32 31 14.94 2973 1377 1.65 / 566.12 2 3
4 13 1731.92 18 14.91 2680 719 2.37 / 566.84 2 4
5 13 1136.04 18 14.95 1924 518 2.89 / 567.36 2 5
6 13 601.00 18 15.04 1221 331 3.22 / 567.69 2 5
7 13 317.12 18 15.10 834 227 3.44 / 567.92 2 4
8 8 0.12 165 15.16 339 848 4.29 / 568.77 2 5
Average= 4.24
(KJ/cycle)

Cycle 132 GMT 8/12/2022 0:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 32 15.13 480 232 0.23 / 560.15 2 3
2 7 2006.52 31 14.95 2966 1375 1.61 / 561.53 2 5
3 13 1743.40 18 14.92 2664 715 2.32 / 562.24 2 5
4 13 1159.12 18 14.95 1944 523 2.85 / 562.77 2 7
5 13 733.72 18 15.01 1392 376 3.22 / 563.14 2 6
6 13 295.84 18 15.12 797 217 3.44 / 563.36 2 4
7 13 29.48 18 15.18 382 104 3.54 / 563.46 2 2
8 8 0.00 165 15.15 341 852 4.40 / 564.32 2 4
9 14 0.00 30 15.13 346 157 4.55 / 564.47 2 4
Average= 4.24
(KJ/cycle)

Cycle 131 GMT 28/11/2022 2:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 32 15.12 495 240 0.24 / 555.71 2 2
2 7 2006.08 31 14.94 2979 1380 1.62 / 557.09 2 5
3 13 1730.44 18 14.92 2674 718 2.34 / 557.80 2 5
4 13 1272.68 18 14.93 2094 563 2.90 / 558.37 2 5
5 13 691.52 18 15.02 1346 364 3.26 / 558.73 2 6
6 13 271.48 18 15.12 769 209 3.47 / 558.94 2 4
7 13 30.12 18 15.19 389 106 3.58 / 559.05 2 2
8 8 0.28 165 15.15 350 875 4.45 / 559.92 2 5
Average= 4.24
(KJ/cycle)

Cycle 130 GMT 18/11/2022 4:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 32 15.13 485 235 0.23 / 551.38 2 2
2 7 2009.00 31 14.94 2985 1382 1.62 / 552.76 2 3
3 13 1598.04 18 14.93 2513 675 2.29 / 553.44 2 4
4 13 1071.80 18 14.96 1840 495 2.79 / 553.93 2 5
5 13 659.40 18 15.02 1309 354 3.14 / 554.29 2 5
6 13 235.96 18 15.13 716 195 3.34 / 554.48 2 5
7 13 42.04 18 15.18 411 112 3.45 / 554.59 2 2
8 8 0.00 165 15.15 349 872 4.32 / 555.47 2 3
Average= 4.24
(KJ/cycle)

Cycle 129 GMT 8/11/2022 7: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.88 32 15.13 505 245 0.24 / 547.00 2 2
2 3 1017.08 1 15.24 1804 27 0.27 / 547.03 2 4
3 7 2002.64 31 14.95 2964 1374 1.65 / 548.40 2 4
4 13 1729.24 18 14.93 2665 716 2.36 / 549.12 2 4
5 13 1166.12 18 14.95 1955 526 2.89 / 549.65 2 5
6 13 732.20 18 15.01 1389 375 3.26 / 550.02 2 5
7 13 167.04 18 15.16 608 166 3.43 / 550.19 2 5
8 13 39.44 18 15.19 391 107 3.54 / 550.29 2 3
9 8 0.04 165 15.16 340 850 4.39 / 551.14 2 11
Average= 4.24
(KJ/cycle)

Cycle 128 GMT 29/10/2022 9:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 32 15.13 496 240 0.24 / 542.68 2 2
2 7 2008.00 32 14.94 2967 1418 1.66 / 544.09 2 3
3 13 1597.16 18 14.94 2500 672 2.33 / 544.77 2 5
4 13 1168.08 18 14.95 1959 527 2.86 / 545.29 2 5
5 13 606.00 18 15.04 1237 335 3.19 / 545.63 2 6
6 13 191.48 18 15.15 639 174 3.37 / 545.80 2 5
7 13 38.32 18 15.19 386 106 3.47 / 545.91 2 2
8 8 0.00 165 15.16 340 850 4.32 / 546.76 2 3
Average= 4.24
(KJ/cycle)

Cycle 127 GMT 19/10/2022 11:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 32 15.14 487 236 0.24 / 538.38 2 3
2 7 2004.08 31 14.94 2960 1371 1.61 / 539.75 2 4
3 13 1592.52 18 14.94 2486 669 2.28 / 540.42 2 4
4 13 1173.00 18 14.95 1962 528 2.80 / 540.95 2 6
5 13 720.80 18 15.02 1373 371 3.17 / 541.32 2 5
6 13 155.44 18 15.16 586 160 3.33 / 541.48 2 3
7 13 28.12 18 15.19 379 104 3.44 / 541.58 2 3
8 8 0.12 165 15.16 341 853 4.29 / 542.44 2 4
Average= 4.24
(KJ/cycle)

Cycle 126 GMT 9/10/2022 13:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 33 15.14 493 246 0.25 / 534.06 2 2
2 7 2010.28 31 14.95 2980 1381 1.63 / 535.44 2 4
3 13 1736.60 18 14.93 2655 714 2.34 / 536.16 2 5
4 13 1049.28 18 14.98 1799 485 2.83 / 536.64 2 6
5 13 666.20 18 15.03 1309 354 3.18 / 537.00 2 5
6 13 244.64 18 15.14 707 193 3.37 / 537.19 2 5
7 13 45.32 18 15.19 397 109 3.48 / 537.30 2 4
8 8 0.12 165 15.17 338 846 4.33 / 538.14 2 6
Average= 4.24
(KJ/cycle)

Cycle 125 GMT 29/ 9/2022 15:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 32 15.15 499 242 0.24 / 529.79 2 3
2 7 2003.60 31 14.95 2955 1369 1.61 / 531.16 2 5
3 13 1601.68 18 14.93 2498 671 2.28 / 531.83 2 6
4 13 1049.56 18 14.97 1793 483 2.77 / 532.31 2 6
5 13 762.48 18 15.01 1425 385 3.15 / 532.70 2 5
6 13 174.16 18 15.16 618 169 3.32 / 532.87 2 6
7 13 37.56 18 15.19 381 104 3.42 / 532.97 2 2
8 8 0.08 165 15.16 338 845 4.27 / 533.82 2 9
Average= 4.24
(KJ/cycle)

Cycle 124 GMT 19/ 9/2022 18: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 32 15.14 475 230 0.23 / 525.41 2 3
2 7 2011.48 31 14.95 2978 1380 1.61 / 526.79 2 4
3 13 1738.12 18 14.93 2665 716 2.33 / 527.51 2 3
4 13 1154.44 18 14.96 1935 521 2.85 / 528.03 2 6
5 13 726.76 18 15.02 1380 373 3.22 / 528.40 2 5
6 13 278.88 18 15.13 758 206 3.43 / 528.61 2 5
7 13 31.28 18 15.20 376 103 3.53 / 528.71 2 3
8 8 0.16 165 15.17 333 834 4.36 / 529.55 2 5
Average= 4.24
(KJ/cycle)

Cycle 123 GMT 9/ 9/2022 20:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 33 15.14 485 242 0.24 / 521.14 2 3
2 7 2013.80 32 14.94 2970 1420 1.66 / 522.56 2 4
3 13 1612.64 18 14.93 2504 673 2.34 / 523.23 2 5
4 13 1071.48 18 14.97 1822 491 2.83 / 523.72 2 5
5 13 652.64 18 15.04 1277 346 3.17 / 524.07 2 5
6 13 220.84 18 15.15 669 182 3.35 / 524.25 2 5
7 13 24.52 18 15.20 363 99 3.45 / 524.35 2 3
8 8 0.04 165 15.17 334 836 4.29 / 525.18 2 3
Average= 4.24
(KJ/cycle)

Cycle 122 GMT 30/ 8/2022 22:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.24 32 15.15 500 242 0.24 / 516.76 2 3
2 3 1017.76 1 15.24 1804 27 0.27 / 516.78 2 4
3 7 2011.56 31 14.95 2966 1375 1.64 / 518.16 2 3
4 13 1738.16 18 14.92 2660 714 2.36 / 518.87 2 4
5 13 1149.60 18 14.97 1925 519 2.88 / 519.39 2 4
6 13 714.40 18 15.03 1360 368 3.25 / 519.76 2 5
7 13 281.48 18 15.14 755 206 3.45 / 519.96 2 4
8 13 25.80 18 15.20 363 99 3.55 / 520.06 2 2
9 8 0.12 165 15.17 332 831 4.38 / 520.89 2 10
Average= 4.23
(KJ/cycle)

Cycle 121 GMT 21/ 8/2022 0:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 32 15.14 478 232 0.23 / 512.51 2 3
2 7 2003.80 31 14.95 2966 1375 1.61 / 513.88 2 5
3 13 1594.28 18 14.94 2494 671 2.28 / 514.55 2 5
4 13 1165.20 18 14.96 1942 523 2.80 / 515.08 2 7
5 13 599.52 18 15.06 1213 329 3.13 / 515.40 2 5
6 13 183.44 18 15.16 616 168 3.30 / 515.57 2 4
7 13 36.32 18 15.20 383 105 3.40 / 515.68 2 2
8 8 0.08 165 15.17 334 836 4.24 / 516.51 2 5
Average= 4.23
(KJ/cycle)

Cycle 120 GMT 11/ 8/2022 2:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 32 15.15 483 234 0.23 / 508.28 2 2
2 7 2009.08 31 14.95 2964 1374 1.61 / 509.66 2 4
3 13 1604.52 18 14.94 2497 671 2.28 / 510.33 2 5
4 13 1045.84 18 14.98 1782 480 2.76 / 510.81 2 6
5 13 636.36 18 15.05 1261 342 3.10 / 511.15 2 5
6 13 209.92 18 15.15 653 178 3.28 / 511.33 2 5
7 13 21.28 18 15.20 371 102 3.38 / 511.43 2 2
8 8 0.00 165 15.17 337 844 4.22 / 512.28 2 9
Average= 4.23
(KJ/cycle)

Cycle 119 GMT 1/ 8/2022 4:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 32 15.15 490 238 0.24 / 503.93 2 2
2 7 2007.04 31 14.96 2961 1373 1.61 / 505.30 2 4
3 13 1602.20 18 14.94 2495 671 2.28 / 505.97 2 4
4 13 1170.60 18 14.96 1964 529 2.81 / 506.50 2 5
5 13 732.44 18 15.02 1391 376 3.19 / 506.88 2 6
6 13 295.04 18 15.13 802 218 3.41 / 507.10 2 5
7 13 30.96 18 15.20 380 104 3.51 / 507.20 2 2
8 8 0.00 165 15.17 339 849 4.36 / 508.05 2 3
Average= 4.23
(KJ/cycle)

Cycle 118 GMT 22/ 7/2022 6:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 32 15.15 493 239 0.24 / 499.64 2 3
2 7 2010.64 31 14.96 2973 1379 1.62 / 501.02 2 3
3 13 1606.04 18 14.94 2508 674 2.29 / 501.69 2 4
4 13 1196.56 18 14.96 1998 538 2.83 / 502.23 2 5
5 13 628.76 18 15.06 1260 342 3.17 / 502.57 2 5
6 13 206.32 18 15.16 668 182 3.35 / 502.75 2 4
7 13 21.48 18 15.21 368 101 3.45 / 502.85 2 2
8 8 0.12 165 15.17 336 841 4.30 / 503.69 2 4
Average= 4.23
(KJ/cycle)

Cycle 117 GMT 12/ 7/2022 8:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 32 15.15 497 241 0.24 / 495.32 2 3
2 3 1017.44 1 15.25 1814 28 0.27 / 495.34 2 4
3 7 2006.36 31 14.96 2964 1375 1.64 / 496.72 2 4
4 13 1745.08 18 14.93 2674 719 2.36 / 497.44 2 4
5 13 1034.52 18 15.00 1781 481 2.84 / 497.92 2 5
6 13 643.36 18 15.05 1276 346 3.19 / 498.26 2 5
7 13 230.56 18 15.15 702 191 3.38 / 498.46 2 6
8 13 21.52 18 15.21 365 100 3.48 / 498.56 2 2
9 8 0.08 165 15.18 336 842 4.32 / 499.40 2 3
Average= 4.23
(KJ/cycle)

Cycle 116 GMT 2/ 7/2022 10:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 32 15.15 485 235 0.24 / 491.00 2 2
2 7 2005.44 31 14.95 2956 1370 1.61 / 492.37 2 4
3 13 1730.12 18 14.93 2650 712 2.32 / 493.09 2 5
4 13 1149.88 18 14.97 1930 520 2.84 / 493.61 2 5
5 13 707.56 18 15.04 1356 367 3.20 / 493.97 2 6
6 13 149.56 18 15.18 570 156 3.36 / 494.13 2 3
7 13 12.08 18 15.21 356 97 3.46 / 494.23 2 2
8 8 0.04 165 15.18 339 849 4.31 / 495.08 2 3
Average= 4.23
(KJ/cycle)

Cycle 115 GMT 22/ 6/2022 13: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 32 15.16 474 230 0.23 / 486.74 2 2
2 7 2011.08 31 14.95 2981 1382 1.61 / 488.12 2 4
3 13 1747.60 18 14.93 2674 719 2.33 / 488.84 2 4
4 13 1020.32 18 15.00 1767 477 2.81 / 489.31 2 5
5 13 620.32 18 15.06 1235 335 3.14 / 489.65 2 5
6 13 194.24 18 15.17 639 174 3.32 / 489.82 2 5
7 13 14.32 18 15.21 358 98 3.41 / 489.92 2 2
8 8 -0.04 165 15.17 339 849 4.26 / 490.77 2 3
Average= 4.23
(KJ/cycle)

Cycle 114 GMT 12/ 6/2022 14:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 32 15.15 497 241 0.24 / 482.47 2 3
2 7 2009.76 32 14.95 2974 1423 1.66 / 483.90 2 5
3 13 1602.24 18 14.95 2497 672 2.34 / 484.57 2 5
4 13 1171.04 18 14.97 1954 527 2.86 / 485.09 2 5
5 13 716.96 18 15.03 1369 370 3.23 / 485.46 2 6
6 13 275.28 18 15.14 754 205 3.44 / 485.67 2 4
7 8 0.16 165 15.18 334 837 4.27 / 486.51 2 6
Average= 4.23
(KJ/cycle)

Cycle 113 GMT 2/ 6/2022 16:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.72 31 15.15 509 239 0.24 / 478.27 2 3
2 3 1028.64 1 15.23 1813 28 0.27 / 478.30 2 5
3 7 2010.16 31 14.96 2969 1377 1.64 / 479.68 2 3
4 13 1616.28 18 14.95 2513 676 2.32 / 480.35 2 4
5 13 1077.40 18 14.98 1831 494 2.81 / 480.85 2 6
6 13 669.48 18 15.05 1304 353 3.17 / 481.20 2 6
7 13 233.56 18 15.16 693 189 3.36 / 481.39 2 5
8 8 -0.04 165 15.19 336 842 4.20 / 482.23 2 6
Average= 4.23
(KJ/cycle)

Cycle 112 GMT 23/ 5/2022 18:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 32 15.15 485 235 0.24 / 474.03 2 3
2 3 977.40 -1 15.53 13 0 0.00 / 474.03 2 3
3 7 2002.52 31 14.96 2956 1371 1.61 / 475.40 2 4
4 13 1601.64 18 14.95 2501 673 2.28 / 476.07 2 5
5 13 1058.72 18 14.99 1810 488 2.77 / 476.56 2 7
6 13 646.28 18 15.05 1273 345 3.11 / 476.91 2 5
7 13 220.68 18 15.16 687 187 3.30 / 477.09 2 5
8 13 21.04 18 15.21 365 100 3.40 / 477.19 2 4
9 8 0.12 165 15.18 335 839 4.24 / 478.03 2 3
Average= 4.23
(KJ/cycle)

Cycle 111 GMT 13/ 5/2022 20:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.80 32 15.16 513 249 0.25 / 469.88 2 2
2 7 2002.80 31 14.96 2965 1375 1.62 / 471.25 2 4
3 13 1601.20 18 14.95 2499 672 2.30 / 471.93 2 4
4 13 1164.88 18 14.97 1946 524 2.82 / 472.45 2 5
5 13 606.04 18 15.07 1219 331 3.15 / 472.78 2 6
6 13 191.00 18 15.17 626 171 3.32 / 472.95 2 4
7 8 0.16 165 15.19 336 842 4.16 / 473.80 2 5
Average= 4.23
(KJ/cycle)

Cycle 110 GMT 3/ 5/2022 23: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.12 32 15.15 522 253 0.25 / 465.67 2 2
2 7 2003.40 32 14.96 2954 1414 1.67 / 467.09 2 4
3 13 1590.56 18 14.96 2485 669 2.34 / 467.76 2 5
4 13 1160.72 18 14.98 1942 524 2.86 / 468.28 2 5
5 13 596.04 18 15.07 1213 329 3.19 / 468.61 2 6
6 13 176.36 18 15.18 618 169 3.36 / 468.78 2 4
7 8 0.16 165 15.19 340 852 4.21 / 469.63 2 2
Average= 4.23
(KJ/cycle)

Cycle 109 GMT 24/ 4/2022 1:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 32 15.16 505 245 0.24 / 461.50 2 3
2 7 2012.44 31 14.96 2977 1381 1.63 / 462.88 2 5
3 13 1589.44 18 14.95 2489 670 2.30 / 463.55 2 5
4 13 1047.92 18 15.00 1791 484 2.78 / 464.04 2 6
5 13 638.04 18 15.06 1262 342 3.12 / 464.38 2 6
6 13 211.80 18 15.17 667 182 3.30 / 464.56 2 5
7 8 0.00 165 15.18 343 859 4.16 / 465.42 2 2
Average= 4.23
(KJ/cycle)

Cycle 108 GMT 14/ 4/2022 3:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 32 15.15 498 241 0.24 / 457.11 2 3
2 7 2011.40 31 14.96 2972 1378 1.62 / 458.49 2 5
3 13 1734.24 18 14.94 2655 714 2.33 / 459.20 2 4
4 13 1154.20 18 14.98 1940 523 2.86 / 459.72 2 6
5 13 716.48 18 15.04 1373 372 3.23 / 460.09 2 6
6 13 159.36 18 15.19 591 162 3.39 / 460.26 2 4
7 8 0.12 165 15.19 338 847 4.24 / 461.10 2 3
8 14 0.12 30 15.17 341 155 4.39 / 461.26 2 3
Average= 4.23
(KJ/cycle)

Cycle 107 GMT 4/ 4/2022 5:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 32 15.15 524 254 0.25 / 452.95 2 3
2 7 2008.72 31 14.96 2958 1372 1.63 / 454.32 2 4
3 13 1603.28 18 14.96 2496 672 2.30 / 454.99 2 4
4 13 1066.16 18 15.00 1816 490 2.79 / 455.48 2 6
5 13 649.60 18 15.06 1281 347 3.14 / 455.83 2 6
6 13 231.64 18 15.16 694 189 3.32 / 456.02 2 5
7 8 0.00 165 15.19 339 850 4.17 / 456.87 2 10
Average= 4.23
(KJ/cycle)

Cycle 106 GMT 25/ 3/2022 7:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 32 15.15 515 250 0.25 / 448.79 2 3
2 7 2002.64 31 14.97 2951 1369 1.62 / 450.16 2 4
3 13 1591.80 18 14.96 2489 670 2.29 / 450.83 2 4
4 13 1155.84 18 14.98 1929 520 2.81 / 451.35 2 6
5 13 597.28 18 15.06 1208 327 3.14 / 451.68 2 5
6 13 185.64 18 15.17 622 170 3.31 / 451.85 2 4
7 8 0.24 165 15.19 336 842 4.15 / 452.69 2 10
Average= 4.23
(KJ/cycle)

Cycle 105 GMT 15/ 3/2022 9:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 32 15.16 522 253 0.25 / 444.61 2 3
2 7 2004.48 31 14.97 2961 1374 1.63 / 445.99 2 5
3 13 1607.12 18 14.96 2505 675 2.30 / 446.66 2 5
4 13 1060.96 18 14.99 1812 489 2.79 / 447.15 2 5
5 13 669.12 18 15.06 1304 353 3.14 / 447.51 2 6
6 13 230.92 18 15.16 693 189 3.33 / 447.70 2 5
7 8 0.16 165 15.19 338 847 4.18 / 448.54 2 3
Average= 4.23
(KJ/cycle)

Cycle 104 GMT 5/ 3/2022 11:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.88 31 15.17 512 241 0.24 / 440.36 2 2
2 3 1025.72 1 15.25 1816 28 0.27 / 440.38 2 4
3 7 2007.32 31 14.97 2976 1381 1.65 / 441.77 2 4
4 13 1604.92 18 14.96 2505 675 2.32 / 442.44 2 6
5 13 1188.96 18 14.97 1978 533 2.86 / 442.97 2 7
6 13 745.00 18 15.04 1405 380 3.24 / 443.35 2 6
7 13 178.40 18 15.18 613 167 3.40 / 443.52 2 4
8 8 0.08 165 15.20 335 840 4.25 / 444.36 2 3
Average= 4.23
(KJ/cycle)

Cycle 103 GMT 23/ 2/2022 14: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 31 15.16 500 235 0.23 / 436.21 2 3
2 7 2004.24 31 14.96 2955 1370 1.61 / 437.58 2 4
3 13 1597.08 18 14.96 2496 672 2.28 / 438.25 2 5
4 13 1161.28 18 14.98 1945 524 2.80 / 438.77 2 7
5 13 596.84 18 15.07 1213 329 3.13 / 439.10 2 6
6 13 180.48 18 15.19 617 169 3.30 / 439.27 2 4
7 8 0.12 165 15.20 337 845 4.14 / 440.12 2 3
Average= 4.23
(KJ/cycle)

Cycle 102 GMT 13/ 2/2022 16:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 31 15.16 491 231 0.23 / 432.07 2 2
2 7 2004.88 31 14.97 2977 1382 1.61 / 433.45 2 5
3 13 1603.68 18 14.96 2505 675 2.29 / 434.12 2 5
4 13 1071.16 18 15.00 1829 494 2.78 / 434.62 2 5
5 13 655.04 18 15.06 1295 351 3.13 / 434.97 2 5
6 13 136.48 18 15.20 566 155 3.29 / 435.12 2 3
7 8 0.00 165 15.20 339 850 4.14 / 435.97 2 3
Average= 4.23
(KJ/cycle)

Cycle 101 GMT 3/ 2/2022 18:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 32 15.17 495 240 0.24 / 427.92 2 3
2 7 2008.84 32 14.97 2966 1421 1.66 / 429.34 2 5
3 13 1599.80 18 14.96 2494 672 2.33 / 430.01 2 5
4 13 1044.64 18 15.01 1790 484 2.82 / 430.50 2 6
5 13 630.04 18 15.07 1251 339 3.16 / 430.84 2 5
6 13 123.68 18 15.20 537 147 3.30 / 430.98 2 5
7 8 0.00 165 15.20 339 850 4.15 / 431.83 2 9
Average= 4.23
(KJ/cycle)

Cycle 100 GMT 24/ 1/2022 20:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.04 31 15.17 512 241 0.24 / 423.70 2 3
2 3 1015.24 1 15.27 1814 28 0.27 / 423.73 2 3
3 7 2005.24 31 14.97 2968 1377 1.65 / 425.10 2 5
4 13 1594.92 18 14.96 2500 673 2.32 / 425.78 2 5
5 13 1164.56 18 14.99 1954 527 2.85 / 426.30 2 6
6 13 718.84 18 15.05 1372 372 3.22 / 426.68 2 6
7 13 157.56 18 15.20 591 162 3.38 / 426.84 2 5
8 8 0.12 165 15.20 337 845 4.22 / 427.68 2 4
Average= 4.23
(KJ/cycle)

Cycle 99 GMT 14/ 1/2022 22:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 32 15.17 508 247 0.25 / 419.46 2 3
2 7 2008.48 32 14.96 2988 1430 1.68 / 420.89 2 5
3 13 1607.32 18 14.96 2513 677 2.35 / 421.57 2 4
4 13 1178.40 18 14.98 1968 531 2.88 / 422.10 2 7
5 13 608.64 18 15.08 1234 335 3.22 / 422.44 2 6
6 13 184.28 18 15.19 633 173 3.39 / 422.61 2 5
7 8 0.12 165 15.20 338 848 4.24 / 423.46 2 3
Average= 4.23
(KJ/cycle)

Cycle 98 GMT 5/ 1/2022 0:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.00 31 15.17 506 238 0.24 / 415.23 2 2
2 3 1024.20 1 15.26 1827 28 0.27 / 415.26 2 4
3 7 2009.36 31 14.96 2982 1383 1.65 / 416.64 2 3
4 13 1733.28 18 14.94 2666 717 2.37 / 417.36 2 5
5 13 1038.48 18 15.01 1797 486 2.85 / 417.84 2 6
6 13 625.20 18 15.08 1254 340 3.19 / 418.18 2 5
7 13 195.12 18 15.19 652 178 3.37 / 418.36 2 5
8 8 0.00 165 15.20 341 855 4.23 / 419.22 2 3
Average= 4.23
(KJ/cycle)

Cycle 97 GMT 26/12/2021 2:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 32 15.17 484 235 0.23 / 410.93 2 3
2 7 2003.60 32 14.97 2970 1423 1.66 / 412.35 2 3
3 13 1595.08 18 14.96 2493 671 2.33 / 413.02 2 5
4 13 1156.24 18 14.98 1952 526 2.86 / 413.55 2 5
5 13 594.64 18 15.09 1207 328 3.18 / 413.88 2 5
6 13 174.64 18 15.19 612 167 3.35 / 414.04 2 4
7 13 37.68 18 15.23 380 104 3.45 / 414.15 2 2
8 8 -0.12 165 15.20 337 845 4.30 / 414.99 2 17
Average= 4.23
(KJ/cycle)

Cycle 96 GMT 16/12/2021 4:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 31 15.17 502 236 0.24 / 406.75 2 3
2 3 1021.84 1 15.27 1808 28 0.26 / 406.78 2 4
3 7 2008.84 31 14.96 2966 1376 1.64 / 408.15 2 5
4 13 1602.20 18 14.96 2506 675 2.31 / 408.83 2 4
5 13 1057.56 18 15.01 1812 490 2.80 / 409.32 2 8
6 13 633.88 18 15.08 1258 341 3.15 / 409.66 2 6
7 13 204.68 18 15.19 658 180 3.32 / 409.84 2 5
8 8 -0.08 165 15.20 340 853 4.18 / 410.69 2 3
Average= 4.23
(KJ/cycle)

Cycle 95 GMT 6/12/2021 6:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 32 15.17 485 235 0.24 / 402.21 2 3
2 7 2004.08 31 14.97 2975 1381 1.62 / 403.60 2 5
3 13 1725.96 18 14.95 2664 717 2.33 / 404.31 2 6
4 13 1139.84 18 15.00 1921 519 2.85 / 404.83 2 6
5 13 704.76 18 15.07 1352 367 3.22 / 405.20 2 6
6 13 270.24 18 15.17 753 206 3.42 / 405.40 2 5
7 13 51.36 18 15.23 397 109 3.53 / 405.51 2 3
8 8 0.04 165 15.20 338 848 4.38 / 406.36 2 12
9 14 0.04 30 15.18 340 155 4.54 / 406.51 2 4
Average= 4.23
(KJ/cycle)

Cycle 94 GMT 26/11/2021 8:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 32 15.17 495 240 0.24 / 397.88 2 3
2 7 2005.44 31 14.98 2963 1376 1.62 / 399.26 2 5
3 13 1596.88 18 14.96 2498 673 2.29 / 399.93 2 4
4 13 1166.88 18 14.99 1953 527 2.82 / 400.46 2 7
5 13 710.40 18 15.06 1363 369 3.19 / 400.83 2 6
6 13 262.80 18 15.17 744 203 3.39 / 401.03 2 5
7 13 48.76 18 15.22 395 108 3.50 / 401.14 2 2
8 8 0.04 165 15.20 335 840 4.34 / 401.98 2 3
Average= 4.23
(KJ/cycle)

Cycle 93 GMT 16/11/2021 10:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.12 32 15.18 488 237 0.24 / 393.58 2 3
2 7 2003.24 31 14.96 2982 1383 1.62 / 394.97 2 3
3 13 1611.00 18 14.96 2521 679 2.30 / 395.65 2 5
4 13 1196.96 18 14.98 1993 537 2.84 / 396.18 2 7
5 13 614.48 18 15.08 1234 335 3.17 / 396.52 2 6
6 13 189.96 18 15.19 638 174 3.35 / 396.69 2 5
7 13 40.32 18 15.23 383 105 3.45 / 396.80 2 2
8 8 0.00 165 15.20 337 845 4.30 / 397.64 2 3
Average= 4.23
(KJ/cycle)

Cycle 92 GMT 6/11/2021 13: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 32 15.17 483 234 0.23 / 389.25 2 3
2 7 2009.40 31 14.97 2987 1386 1.62 / 390.63 2 3
3 13 1739.68 18 14.95 2672 719 2.34 / 391.35 2 4
4 13 1162.00 18 14.99 1946 525 2.86 / 391.88 2 7
5 13 619.80 18 15.09 1245 338 3.20 / 392.22 2 5
6 13 209.60 18 15.19 667 182 3.39 / 392.40 2 5
7 13 45.88 18 15.23 393 108 3.49 / 392.51 2 2
8 8 -0.04 165 15.21 335 841 4.33 / 393.35 2 3
Average= 4.23
(KJ/cycle)

Cycle 91 GMT 27/10/2021 15: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.12 32 15.18 501 243 0.24 / 384.82 2 2
2 7 2003.24 31 14.97 2974 1380 1.62 / 386.20 2 4
3 13 1611.52 18 14.96 2511 676 2.30 / 386.88 2 6
4 13 1073.32 18 15.01 1831 495 2.79 / 387.38 2 5
5 13 651.20 18 15.08 1281 348 3.14 / 387.72 2 6
6 13 228.20 18 15.18 692 189 3.33 / 387.91 2 4
7 13 44.92 18 15.23 393 108 3.44 / 388.02 2 2
8 8 0.08 165 15.20 335 840 4.28 / 388.86 2 2
9 14 0.08 30 15.18 334 152 4.43 / 389.01 2 3
Average= 4.23
(KJ/cycle)

Cycle 90 GMT 17/10/2021 16:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 32 15.17 514 250 0.25 / 380.53 2 3
2 7 2009.76 32 14.97 2974 1425 1.67 / 381.95 2 4
3 13 1604.28 18 14.96 2508 675 2.35 / 382.63 2 4
4 13 1050.72 18 15.02 1801 487 2.84 / 383.11 2 5
5 13 632.56 18 15.08 1256 341 3.18 / 383.45 2 6
6 13 208.84 18 15.19 662 181 3.36 / 383.64 2 5
7 13 47.08 18 15.23 393 108 3.47 / 383.74 2 3
8 8 0.04 165 15.21 334 838 4.30 / 384.58 2 5
Average= 4.23
(KJ/cycle)

Cycle 89 GMT 7/10/2021 18:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 32 15.18 507 246 0.25 / 376.22 2 3
2 7 2007.44 31 14.96 2977 1381 1.63 / 377.60 2 3
3 13 1588.96 18 14.97 2489 671 2.30 / 378.27 2 5
4 13 1058.64 18 15.01 1816 491 2.79 / 378.76 2 5
5 13 637.60 18 15.08 1270 345 3.13 / 379.11 2 6
6 13 205.32 18 15.19 673 184 3.32 / 379.29 2 4
7 13 43.76 18 15.23 406 111 3.43 / 379.40 2 2
8 8 0.12 165 15.20 349 875 4.30 / 380.28 2 6
Average= 4.23
(KJ/cycle)

Cycle 88 GMT 27/ 9/2021 20:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.32 32 15.18 507 246 0.25 / 371.89 2 3
2 7 2003.16 31 14.96 2964 1375 1.62 / 373.26 2 5
3 13 1605.92 18 14.96 2516 678 2.30 / 373.94 2 4
4 13 1170.88 18 14.99 1964 530 2.83 / 374.47 2 8
5 13 713.52 18 15.06 1367 371 3.20 / 374.84 2 6
6 13 142.20 18 15.21 585 160 3.36 / 375.00 2 5
7 13 34.52 18 15.23 396 109 3.47 / 375.11 2 3
8 8 0.16 165 15.21 345 866 4.33 / 375.97 2 3
Average= 4.22
(KJ/cycle)

Cycle 87 GMT 17/ 9/2021 23: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.88 32 15.17 505 245 0.25 / 367.58 2 3
2 7 2006.48 31 14.96 2967 1376 1.62 / 368.96 2 3
3 13 1728.92 18 14.95 2651 713 2.33 / 369.67 2 5
4 13 1130.84 18 15.00 1907 515 2.85 / 370.19 2 7
5 13 586.72 18 15.10 1201 326 3.18 / 370.51 2 6
6 13 168.92 18 15.20 607 166 3.34 / 370.68 2 4
7 13 37.08 18 15.24 386 106 3.45 / 370.78 2 2
8 8 0.20 165 15.21 341 856 4.30 / 371.64 2 3
Average= 4.22
(KJ/cycle)

Cycle 86 GMT 8/ 9/2021 1:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 32 15.18 479 233 0.23 / 363.29 2 2
2 7 2003.76 32 14.97 2960 1418 1.65 / 364.71 2 5
3 13 1596.60 18 14.97 2490 671 2.32 / 365.38 2 5
4 13 1049.24 18 15.02 1798 486 2.81 / 365.87 2 5
5 13 632.56 18 15.09 1256 341 3.15 / 366.21 2 5
6 13 189.76 18 15.19 637 174 3.32 / 366.38 2 5
7 13 36.12 18 15.23 383 105 3.43 / 366.49 2 2
8 8 0.08 165 15.20 339 850 4.28 / 367.34 2 10
Average= 4.22
(KJ/cycle)

Cycle 85 GMT 29/ 8/2021 3:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 32 15.18 475 231 0.23 / 359.01 2 3
2 7 2010.72 31 14.98 2958 1374 1.60 / 360.38 2 4
3 13 1609.84 18 14.97 2515 678 2.28 / 361.06 2 6
4 13 1174.24 18 14.99 1964 530 2.81 / 361.59 2 5
5 13 613.28 18 15.09 1234 335 3.15 / 361.93 2 5
6 13 207.56 18 15.19 659 180 3.33 / 362.11 2 4
7 13 23.92 18 15.24 370 101 3.43 / 362.21 2 2
8 8 0.08 165 15.20 339 850 4.28 / 363.06 2 5
Average= 4.22
(KJ/cycle)

Cycle 84 GMT 19/ 8/2021 5:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 32 15.17 475 231 0.23 / 354.71 2 3
2 7 2005.52 31 14.98 2976 1382 1.61 / 356.09 2 5
3 13 1606.44 18 14.97 2508 676 2.29 / 356.77 2 5
4 13 1172.56 18 14.99 1954 527 2.82 / 357.30 2 5
5 13 730.52 18 15.06 1390 377 3.19 / 357.67 2 6
6 13 161.92 18 15.20 593 162 3.35 / 357.84 2 4
7 13 36.44 18 15.23 384 105 3.46 / 357.94 2 2
8 8 0.08 165 15.21 334 838 4.30 / 358.78 2 9
Average= 4.22
(KJ/cycle)

Cycle 83 GMT 9/ 8/2021 7:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 32 15.17 474 230 0.23 / 350.43 2 3
2 7 2008.40 32 14.97 2967 1421 1.65 / 351.85 2 3
3 13 1595.56 18 14.96 2505 675 2.33 / 352.52 2 4
4 13 1038.44 18 15.01 1803 487 2.81 / 353.01 2 5
5 13 622.76 18 15.08 1246 338 3.15 / 353.35 2 5
6 13 187.04 18 15.19 637 174 3.33 / 353.52 2 4
7 13 36.88 18 15.23 397 109 3.43 / 353.63 2 3
8 8 0.08 165 15.20 339 850 4.28 / 354.48 2 11
Average= 4.22
(KJ/cycle)

Cycle 82 GMT 30/ 7/2021 9:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 32 15.17 477 232 0.23 / 346.18 2 3
2 7 2004.36 31 14.98 2957 1373 1.60 / 347.55 2 5
3 13 1601.44 18 14.97 2501 674 2.28 / 348.22 2 6
4 13 1166.88 18 14.99 1958 528 2.81 / 348.75 2 6
5 13 600.84 18 15.09 1220 331 3.14 / 349.08 2 6
6 13 183.48 18 15.20 617 169 3.31 / 349.25 2 5
7 13 38.76 18 15.23 388 106 3.41 / 349.36 2 3
8 8 0.08 165 15.20 334 838 4.25 / 350.20 2 4
Average= 4.22
(KJ/cycle)

Cycle 81 GMT 20/ 7/2021 11:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 31 15.17 485 228 0.23 / 341.69 2 3
2 7 2005.36 31 14.99 2975 1382 1.61 / 343.07 2 4
3 13 1603.28 18 14.98 2506 676 2.29 / 343.75 2 4
4 13 1164.68 18 15.00 1951 527 2.81 / 344.27 2 7
5 13 715.96 18 15.06 1368 371 3.18 / 344.65 2 6
6 13 272.20 18 15.17 750 205 3.39 / 344.85 2 5
7 13 28.92 18 15.23 371 102 3.49 / 344.95 2 2
8 8 0.16 165 15.20 335 840 4.33 / 345.79 2 3
9 14 0.16 30 15.18 337 153 4.48 / 345.95 2 7
Average= 4.22
(KJ/cycle)

Cycle 80 GMT 10/ 7/2021 13:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 31 15.17 483 227 0.23 / 337.41 2 3
2 7 2005.32 31 14.98 2976 1382 1.61 / 338.79 2 4
3 13 1597.64 18 14.98 2494 672 2.28 / 339.47 2 5
4 13 1171.92 18 14.99 1966 530 2.81 / 340.00 2 5
5 13 617.72 18 15.09 1241 337 3.15 / 340.33 2 6
6 13 190.04 18 15.20 629 172 3.32 / 340.51 2 4
7 13 36.68 18 15.23 389 107 3.43 / 340.61 2 2
8 8 0.04 165 15.20 338 848 4.28 / 341.46 2 6
Average= 4.22
(KJ/cycle)

Cycle 79 GMT 30/ 6/2021 15:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.36 31 15.17 488 229 0.23 / 333.13 2 2
2 7 2011.32 31 14.97 2985 1385 1.61 / 334.52 2 4
3 13 1609.08 18 14.97 2524 680 2.29 / 335.20 2 5
4 13 1168.12 18 15.00 1969 532 2.83 / 335.73 2 5
5 13 597.24 18 15.10 1210 329 3.16 / 336.06 2 6
6 13 184.24 18 15.19 631 173 3.33 / 336.23 2 4
7 13 18.88 18 15.24 366 100 3.43 / 336.33 2 3
8 8 0.12 165 15.20 340 853 4.28 / 337.19 2 4
Average= 4.21
(KJ/cycle)

Cycle 78 GMT 20/ 6/2021 18: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 31 15.18 508 239 0.24 / 328.75 2 3
2 7 2007.00 31 14.99 2969 1380 1.62 / 330.13 2 3
3 13 1733.52 18 14.97 2678 722 2.34 / 330.85 2 5
4 13 1146.44 18 15.01 1924 520 2.86 / 331.37 2 7
5 13 708.24 18 15.07 1367 371 3.23 / 331.74 2 6
6 13 269.76 18 15.17 755 206 3.44 / 331.95 2 5
7 13 23.28 18 15.23 371 102 3.54 / 332.05 2 2
8 8 0.00 165 15.20 340 853 4.39 / 332.90 2 6
Average= 4.21
(KJ/cycle)

Cycle 77 GMT 10/ 6/2021 20:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.16 31 15.18 504 237 0.24 / 324.51 2 3
2 7 2004.48 32 14.99 2974 1427 1.66 / 325.93 2 4
3 13 1721.28 18 14.97 2649 714 2.38 / 326.65 2 5
4 13 1116.16 18 15.01 1891 511 2.89 / 327.16 2 5
5 13 675.88 18 15.08 1317 357 3.25 / 327.51 2 5
6 13 132.68 18 15.21 552 151 3.40 / 327.66 2 4
7 8 0.20 165 15.21 338 848 4.25 / 328.51 2 3
Average= 4.21
(KJ/cycle)

Cycle 76 GMT 31/ 5/2021 22:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 31 15.17 495 233 0.23 / 320.27 2 3
2 7 2003.76 32 14.99 2966 1423 1.66 / 321.69 2 4
3 13 1589.04 18 14.99 2485 671 2.33 / 322.36 2 5
4 13 1156.12 18 15.01 1947 526 2.85 / 322.89 2 6
5 13 705.20 18 15.07 1360 369 3.22 / 323.26 2 6
6 13 139.24 18 15.21 567 155 3.38 / 323.41 2 4
7 8 0.12 165 15.21 340 853 4.23 / 324.27 2 4
Average= 4.21
(KJ/cycle)

Cycle 75 GMT 22/ 5/2021 0:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 32 15.18 490 238 0.24 / 316.06 2 3
2 7 2004.20 32 14.99 2975 1427 1.67 / 317.49 2 4
3 13 1602.04 18 14.99 2517 679 2.34 / 318.17 2 6
4 13 1057.32 18 15.02 1817 491 2.84 / 318.66 2 6
5 13 630.80 18 15.09 1261 343 3.18 / 319.00 2 6
6 13 195.60 18 15.19 651 178 3.36 / 319.18 2 5
7 8 0.08 165 15.21 341 856 4.21 / 320.04 2 5
Average= 4.21
(KJ/cycle)

Cycle 74 GMT 12/ 5/2021 2:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.84 32 15.18 504 245 0.24 / 311.93 2 3
2 7 2003.00 31 14.99 2981 1385 1.63 / 313.32 2 5
3 13 1591.88 18 14.99 2496 673 2.30 / 313.99 2 4
4 13 1029.04 18 15.04 1776 481 2.78 / 314.47 2 5
5 13 612.16 18 15.10 1233 335 3.12 / 314.81 2 6
6 13 189.56 18 15.20 632 173 3.29 / 314.98 2 4
7 8 0.12 165 15.21 338 848 4.14 / 315.83 2 2
Average= 4.21
(KJ/cycle)

Cycle 73 GMT 2/ 5/2021 4:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 32 15.18 511 248 0.25 / 307.76 2 3
2 7 2004.24 31 15.01 2982 1388 1.64 / 309.15 2 4
3 13 1598.00 18 15.01 2500 675 2.31 / 309.82 2 5
4 13 1046.28 18 15.04 1806 489 2.80 / 310.31 2 6
5 13 629.72 18 15.10 1257 342 3.14 / 310.65 2 6
6 13 200.40 18 15.20 652 178 3.32 / 310.83 2 4
7 8 0.16 165 15.21 340 853 4.17 / 311.69 2 3
Average= 4.21
(KJ/cycle)

Cycle 72 GMT 22/ 4/2021 6:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 32 15.19 513 249 0.25 / 303.58 2 2
2 7 2006.36 31 15.01 2985 1389 1.64 / 304.97 2 4
3 13 1601.80 18 15.01 2507 677 2.32 / 305.65 2 4
4 13 1035.40 18 15.05 1791 485 2.80 / 306.14 2 6
5 13 623.92 18 15.10 1253 341 3.14 / 306.48 2 6
6 13 190.16 18 15.20 641 175 3.32 / 306.65 2 6
7 8 0.20 165 15.22 343 861 4.18 / 307.51 2 5
Average= 4.21
(KJ/cycle)

Cycle 71 GMT 12/ 4/2021 8:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.20 32 15.19 507 246 0.25 / 299.35 2 2
2 7 2004.28 31 15.02 2980 1388 1.63 / 300.73 2 4
3 13 1590.20 18 15.01 2492 673 2.31 / 301.41 2 4
4 13 1159.24 18 15.03 1949 527 2.83 / 301.93 2 5
5 13 717.60 18 15.08 1376 374 3.21 / 302.31 2 5
6 13 158.88 18 15.22 595 163 3.37 / 302.47 2 4
7 8 0.08 165 15.22 344 864 4.23 / 303.33 2 3
Average= 4.21
(KJ/cycle)

Cycle 70 GMT 2/ 4/2021 10:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.36 32 15.19 510 248 0.25 / 295.16 2 3
2 7 2003.44 31 15.02 2967 1381 1.63 / 296.54 2 5
3 13 1593.72 18 15.01 2497 675 2.30 / 297.22 2 5
4 13 1030.68 18 15.05 1785 484 2.79 / 297.70 2 5
5 13 738.00 18 15.08 1405 381 3.17 / 298.08 2 5
6 13 160.52 18 15.22 603 165 3.33 / 298.25 2 4
7 8 -0.12 165 15.22 339 851 4.19 / 299.10 2 2
Average= 4.21
(KJ/cycle)

Cycle 69 GMT 23/ 3/2021 12:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.96 31 15.19 522 246 0.25 / 290.73 2 2
2 7 2008.44 31 15.03 2973 1385 1.63 / 292.12 2 4
3 13 1744.04 18 15.01 2680 724 2.36 / 292.84 2 4
4 13 1149.92 18 15.04 1938 525 2.88 / 293.37 2 7
5 13 723.12 18 15.09 1388 377 3.26 / 293.74 2 6
6 13 158.96 18 15.23 594 163 3.42 / 293.91 2 4
7 8 -0.04 165 15.23 340 854 4.27 / 294.76 2 3
8 14 -0.04 30 15.21 336 153 4.43 / 294.91 2 3
Average= 4.21
(KJ/cycle)

Cycle 68 GMT 13/ 3/2021 14:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.96 31 15.20 517 244 0.24 / 286.49 2 3
2 3 1015.68 1 15.30 1813 28 0.27 / 286.52 2 4
3 7 2003.56 31 15.02 2979 1387 1.66 / 287.90 2 5
4 13 1590.12 18 15.02 2488 673 2.33 / 288.58 2 6
5 13 1141.88 18 15.04 1937 524 2.86 / 289.10 2 6
6 13 695.48 18 15.10 1346 366 3.22 / 289.47 2 7
7 13 134.32 18 15.24 563 154 3.38 / 289.62 2 4
8 8 0.04 165 15.23 344 864 4.24 / 290.49 2 7
Average= 4.21
(KJ/cycle)

Cycle 67 GMT 3/ 3/2021 16:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 32 15.20 494 240 0.24 / 282.36 2 3
2 7 2004.96 31 15.03 2982 1389 1.63 / 283.75 2 3
3 13 1482.20 18 15.03 2362 639 2.27 / 284.39 2 4
4 13 1057.36 18 15.06 1818 493 2.76 / 284.88 2 4
5 13 633.00 18 15.11 1271 346 3.11 / 285.23 2 5
6 13 118.68 18 15.24 535 147 3.25 / 285.37 2 5
7 8 0.28 165 15.23 347 872 4.13 / 286.25 2 3
Average= 4.21
(KJ/cycle)

Cycle 66 GMT 21/ 2/2021 18: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.84 32 15.20 514 250 0.25 / 278.13 2 3
2 7 2002.92 31 15.04 2968 1384 1.63 / 279.52 2 3
3 13 1585.36 18 15.03 2494 675 2.31 / 280.19 2 3
4 13 1160.00 18 15.05 1955 530 2.84 / 280.72 2 4
5 13 727.16 18 15.10 1388 377 3.22 / 281.10 2 5
6 13 157.08 18 15.24 593 163 3.38 / 281.26 2 4
7 8 0.20 165 15.24 342 860 4.24 / 282.12 2 5
Average= 4.21
(KJ/cycle)

Cycle 65 GMT 11/ 2/2021 20: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 32 15.21 497 242 0.24 / 273.84 2 3
2 7 2003.28 31 15.04 2982 1390 1.63 / 275.23 2 3
3 13 1596.48 18 15.03 2501 677 2.31 / 275.91 2 3
4 13 1169.48 18 15.05 1959 531 2.84 / 276.44 2 4
5 13 720.12 18 15.11 1381 376 3.22 / 276.82 2 5
6 13 265.12 18 15.21 747 205 3.42 / 277.02 2 4
7 8 -0.12 165 15.24 343 863 4.28 / 277.88 2 4
Average= 4.21
(KJ/cycle)

Cycle 64 GMT 1/ 2/2021 22:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 32 15.22 511 249 0.25 / 269.67 2 2
2 7 2006.32 31 15.03 2981 1389 1.64 / 271.06 2 3
3 13 1580.84 18 15.04 2481 672 2.31 / 271.73 2 4
4 13 1018.52 18 15.08 1764 479 2.79 / 272.21 2 5
5 13 607.92 18 15.14 1225 334 3.12 / 272.54 2 5
6 13 178.92 18 15.24 632 173 3.30 / 272.72 2 4
7 8 -0.08 165 15.25 351 883 4.18 / 273.60 2 3
Average= 4.21
(KJ/cycle)

Cycle 63 GMT 23/ 1/2021 0:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 31 15.22 514 243 0.24 / 265.30 2 2
2 7 2008.32 31 15.04 2978 1388 1.63 / 266.69 2 3
3 13 1613.20 18 15.03 2527 684 2.31 / 267.37 2 3
4 13 1169.48 18 15.05 1966 533 2.85 / 267.91 2 4
5 13 594.24 18 15.15 1218 332 3.18 / 268.24 2 5
6 13 178.40 18 15.25 622 171 3.35 / 268.41 2 5
7 8 0.16 165 15.26 340 856 4.21 / 269.26 2 3
8 14 0.16 30 15.23 343 157 4.36 / 269.42 2 6
Average= 4.21
(KJ/cycle)

Cycle 62 GMT 13/ 1/2021 2:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 31 15.23 512 242 0.24 / 260.90 2 3
2 7 2008.12 31 15.04 2980 1389 1.63 / 262.29 2 3
3 13 1612.44 18 15.04 2526 684 2.31 / 262.97 2 4
4 13 1188.16 18 15.06 1985 538 2.85 / 263.51 2 4
5 13 625.76 18 15.15 1259 343 3.20 / 263.85 2 5
6 13 203.92 18 15.25 657 180 3.38 / 264.03 2 4
7 8 0.04 165 15.26 344 866 4.24 / 264.90 2 2
8 14 0.04 30 15.24 345 158 4.40 / 265.06 2 5
Average= 4.21
(KJ/cycle)

Cycle 61 GMT 3/ 1/2021 4:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.96 31 15.23 522 246 0.25 / 256.70 2 3
2 7 2011.40 32 15.04 2991 1440 1.69 / 258.13 2 3
3 13 1603.84 18 15.04 2517 681 2.37 / 258.82 2 4
4 13 1038.44 18 15.09 1798 488 2.86 / 259.30 2 5
5 13 618.12 18 15.15 1250 341 3.20 / 259.65 2 5
6 13 104.72 18 15.28 511 141 3.34 / 259.79 2 3
7 8 0.04 165 15.27 346 872 4.21 / 260.66 2 2
Average= 4.20
(KJ/cycle)

Cycle 60 GMT 24/12/2020 6:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.36 31 15.24 514 243 0.24 / 252.45 2 2
2 7 2003.04 31 15.06 2977 1390 1.63 / 253.84 2 3
3 13 1598.16 18 15.05 2507 679 2.31 / 254.51 2 4
4 13 1149.84 18 15.07 1946 528 2.84 / 255.04 2 4
5 13 706.28 18 15.13 1377 375 3.21 / 255.42 2 5
6 13 133.04 18 15.27 581 160 3.37 / 255.58 2 4
7 8 0.12 165 15.27 346 872 4.25 / 256.45 2 3
Average= 4.20
(KJ/cycle)

Cycle 59 GMT 14/12/2020 8:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.32 31 15.24 518 245 0.24 / 248.17 2 3
2 7 2011.44 31 15.05 2990 1395 1.64 / 249.57 2 3
3 13 1746.80 18 15.03 2692 728 2.37 / 250.30 2 3
4 13 1148.28 18 15.08 1945 528 2.90 / 250.82 2 4
5 13 594.08 18 15.17 1223 334 3.23 / 251.16 2 5
6 13 178.16 18 15.27 634 174 3.40 / 251.33 2 5
7 8 0.16 165 15.28 345 870 4.27 / 252.20 2 4
Average= 4.20
(KJ/cycle)

Cycle 58 GMT 4/12/2020 10:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 31 15.25 496 234 0.23 / 243.98 2 3
2 7 2003.76 31 15.05 2974 1388 1.62 / 245.37 2 3
3 13 1597.88 18 15.05 2500 677 2.30 / 246.05 2 4
4 13 1042.52 18 15.10 1804 490 2.79 / 246.54 2 5
5 13 618.08 18 15.16 1248 341 3.13 / 246.88 2 5
6 13 179.16 18 15.27 629 173 3.30 / 247.05 2 5
7 8 0.20 165 15.28 348 877 4.18 / 247.93 2 5
Average= 4.20
(KJ/cycle)

Cycle 57 GMT 24/11/2020 12:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.64 30 15.25 521 238 0.24 / 239.71 2 2
2 3 1015.44 1 15.32 1813 28 0.27 / 239.74 2 4
3 7 2005.04 31 15.05 2974 1388 1.65 / 241.13 2 3
4 13 1735.20 18 15.04 2673 724 2.38 / 241.85 2 4
5 13 1122.72 18 15.09 1903 517 2.89 / 242.37 2 5
6 13 680.12 18 15.15 1327 362 3.26 / 242.73 2 5
7 13 123.52 18 15.29 553 152 3.41 / 242.88 2 5
8 8 0.04 165 15.29 344 868 4.28 / 243.75 2 4
Average= 4.20
(KJ/cycle)

Cycle 56 GMT 14/11/2020 14:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.04 31 15.25 484 229 0.23 / 235.53 2 3
2 3 977.96 -1 15.61 12 0 0.00 / 235.53 2 3
3 7 2007.88 32 15.05 2980 1435 1.66 / 236.97 2 3
4 13 1497.36 18 15.07 2378 645 2.31 / 237.61 2 4
5 13 1081.48 18 15.10 1857 505 2.81 / 238.12 2 5
6 13 643.12 18 15.16 1280 349 3.16 / 238.46 2 5
7 13 103.04 18 15.30 509 140 3.30 / 238.60 2 4
8 8 0.04 165 15.29 344 868 4.17 / 239.47 2 4
Average= 4.20
(KJ/cycle)

Cycle 55 GMT 4/11/2020 16:31:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 31 15.26 496 235 0.23 / 231.26 2 2
2 7 2004.24 31 15.06 2973 1388 1.62 / 232.65 2 3
3 13 1599.44 18 15.06 2499 677 2.30 / 233.33 2 4
4 13 1028.80 18 15.11 1789 487 2.79 / 233.82 2 5
5 13 616.48 18 15.18 1244 340 3.13 / 234.16 2 5
6 13 181.68 18 15.28 630 173 3.30 / 234.33 2 4
7 13 31.64 18 15.31 390 107 3.41 / 234.44 2 2
8 8 0.16 165 15.28 343 865 4.27 / 235.30 2 3
Average= 4.20
(KJ/cycle)

Cycle 54 GMT 25/10/2020 18:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 31 15.26 482 228 0.23 / 227.05 2 2
2 7 2008.76 32 15.06 2967 1430 1.66 / 228.48 2 3
3 13 1594.84 18 15.06 2500 678 2.34 / 229.15 2 3
4 13 1149.72 18 15.09 1938 526 2.86 / 229.68 2 4
5 13 572.72 18 15.19 1188 325 3.19 / 230.00 2 5
6 13 156.92 18 15.29 594 163 3.35 / 230.17 2 4
7 8 -0.04 165 15.30 341 861 4.21 / 231.03 2 3
Average= 4.20
(KJ/cycle)

Cycle 53 GMT 15/10/2020 20:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 31 15.27 478 226 0.23 / 222.59 2 3
2 7 2003.68 31 15.07 2972 1388 1.61 / 223.98 2 3
3 13 1596.52 18 15.06 2499 677 2.29 / 224.66 2 4
4 13 1155.16 18 15.10 1939 527 2.82 / 225.18 2 4
5 13 583.24 18 15.19 1204 329 3.15 / 225.51 2 5
6 13 159.40 18 15.29 600 165 3.31 / 225.68 2 5
7 13 32.44 18 15.32 393 108 3.42 / 225.79 2 2
8 8 0.00 165 15.29 346 873 4.29 / 226.66 2 6
9 14 0.00 30 15.27 345 158 4.45 / 226.82 2 5
Average= 4.20
(KJ/cycle)

Cycle 52 GMT 5/10/2020 22:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 31 15.27 491 232 0.23 / 218.31 2 3
2 7 2002.04 31 15.07 2977 1391 1.62 / 219.70 2 3
3 13 1583.28 18 15.07 2480 673 2.30 / 220.38 2 4
4 13 1153.52 18 15.10 1942 528 2.82 / 220.91 2 4
5 13 585.88 18 15.20 1200 328 3.15 / 221.23 2 5
6 13 149.60 18 15.30 588 162 3.31 / 221.40 2 4
7 13 32.52 18 15.33 385 106 3.42 / 221.50 2 3
8 8 0.12 165 15.30 342 863 4.28 / 222.37 2 3
Average= 4.20
(KJ/cycle)

Cycle 51 GMT 26/ 9/2020 0:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 31 15.27 479 227 0.23 / 213.99 2 3
2 7 2008.88 31 15.08 2981 1394 1.62 / 215.39 2 3
3 13 1605.96 18 15.07 2516 682 2.30 / 216.07 2 3
4 13 1042.68 18 15.12 1805 491 2.79 / 216.56 2 4
5 13 630.28 18 15.19 1262 345 3.14 / 216.91 2 5
6 13 205.96 18 15.29 673 185 3.32 / 217.09 2 4
7 13 22.04 18 15.33 390 108 3.43 / 217.20 2 2
8 8 0.12 165 15.30 350 884 4.32 / 218.08 2 3
Average= 4.19
(KJ/cycle)

Cycle 50 GMT 16/ 9/2020 2:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 31 15.28 472 224 0.22 / 209.73 2 2
2 7 2005.28 31 15.08 2970 1388 1.61 / 211.12 2 3
3 13 1592.08 18 15.08 2501 679 2.29 / 211.79 2 3
4 13 1027.48 18 15.13 1782 485 2.78 / 212.28 2 4
5 13 611.16 18 15.20 1244 340 3.12 / 212.62 2 5
6 13 173.04 18 15.30 618 170 3.29 / 212.79 2 4
7 13 33.80 18 15.33 390 108 3.39 / 212.90 2 2
8 8 0.08 165 15.30 344 868 4.26 / 213.77 2 3
Average= 4.19
(KJ/cycle)

Cycle 49 GMT 6/ 9/2020 5: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 31 15.28 494 234 0.23 / 205.38 2 2
2 7 2012.56 32 15.07 2985 1439 1.67 / 206.82 2 3
3 13 1598.40 18 15.07 2498 678 2.35 / 207.50 2 4
4 13 1168.72 18 15.10 1975 537 2.89 / 208.03 2 4
5 13 590.00 18 15.21 1214 332 3.22 / 208.36 2 5
6 13 160.96 18 15.31 604 166 3.39 / 208.53 2 5
7 13 31.04 18 15.34 393 109 3.50 / 208.64 2 2
8 8 0.08 165 15.31 342 864 4.36 / 209.50 2 6
Average= 4.19
(KJ/cycle)

Cycle 48 GMT 27/ 8/2020 7: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 31 15.29 485 230 0.23 / 201.13 2 3
2 7 2003.96 31 15.07 2983 1394 1.62 / 202.52 2 3
3 13 1587.24 18 15.08 2499 678 2.30 / 203.20 2 4
4 13 1038.32 18 15.13 1793 488 2.79 / 203.69 2 4
5 13 614.52 18 15.20 1246 341 3.13 / 204.03 2 5
6 13 93.68 18 15.33 500 138 3.27 / 204.16 2 4
7 13 25.44 18 15.34 383 106 3.37 / 204.27 2 2
8 8 -0.04 165 15.31 346 874 4.25 / 205.14 2 5
Average= 4.19
(KJ/cycle)

Cycle 47 GMT 17/ 8/2020 9: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 31 15.29 502 238 0.24 / 196.87 2 2
2 3 1013.28 1 15.36 1809 28 0.27 / 196.90 2 3
3 7 2005.80 31 15.08 2969 1388 1.65 / 198.29 2 3
4 13 1594.88 18 15.08 2490 676 2.33 / 198.96 2 4
5 13 1030.12 18 15.14 1784 486 2.82 / 199.45 2 5
6 13 608.84 18 15.21 1232 337 3.15 / 199.79 2 5
7 13 88.96 18 15.34 487 134 3.29 / 199.92 2 4
8 13 25.00 18 15.35 383 106 3.39 / 200.03 2 2
9 8 0.04 165 15.32 343 867 4.26 / 200.90 2 3
Average= 4.19
(KJ/cycle)

Cycle 46 GMT 7/ 8/2020 10:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 31 15.28 488 231 0.23 / 192.57 2 2
2 7 2006.04 31 15.09 2976 1392 1.62 / 193.96 2 3
3 13 1597.24 18 15.09 2506 681 2.30 / 194.65 2 3
4 13 1046.44 18 15.14 1811 494 2.80 / 195.14 2 5
5 13 618.56 18 15.21 1253 343 3.14 / 195.48 2 5
6 13 181.92 18 15.31 631 174 3.31 / 195.66 2 4
7 13 30.96 18 15.35 387 107 3.42 / 195.76 2 2
8 8 0.08 165 15.32 345 872 4.29 / 196.64 2 5
Average= 4.18
(KJ/cycle)

Cycle 45 GMT 28/ 7/2020 13: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 31 15.29 482 228 0.23 / 188.25 2 2
2 7 2003.80 31 15.10 2984 1397 1.63 / 189.64 2 3
3 13 1602.36 18 15.09 2519 684 2.31 / 190.33 2 3
4 13 1160.32 18 15.12 1959 533 2.84 / 190.86 2 4
5 13 591.48 18 15.22 1213 332 3.17 / 191.19 2 5
6 13 164.68 18 15.32 614 169 3.34 / 191.36 2 4
7 13 13.68 18 15.35 372 103 3.45 / 191.46 2 2
8 8 0.12 165 15.32 347 877 4.32 / 192.34 2 3
Average= 4.18
(KJ/cycle)

Cycle 44 GMT 18/ 7/2020 15: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 31 15.30 477 226 0.23 / 184.05 2 2
2 7 2005.88 31 15.09 2978 1393 1.62 / 185.44 2 3
3 13 1606.24 18 15.09 2521 685 2.30 / 186.12 2 3
4 13 1051.88 18 15.15 1811 494 2.80 / 186.62 2 4
5 13 626.64 18 15.21 1259 345 3.14 / 186.96 2 5
6 13 193.12 18 15.32 649 179 3.32 / 187.14 2 4
7 8 0.12 165 15.33 346 875 4.20 / 188.02 2 4
Average= 4.18
(KJ/cycle)

Cycle 43 GMT 8/ 7/2020 17: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 31 15.30 469 222 0.22 / 179.69 2 2
2 7 2002.48 32 15.09 2977 1438 1.66 / 181.12 2 3
3 13 1600.40 18 15.08 2515 683 2.34 / 181.81 2 3
4 13 1036.72 18 15.15 1796 490 2.83 / 182.30 2 4
5 13 609.84 18 15.22 1226 336 3.17 / 182.63 2 5
6 13 168.48 18 15.33 606 167 3.34 / 182.80 2 4
7 8 0.08 165 15.33 342 865 4.20 / 183.66 2 2
8 14 0.08 30 15.31 340 156 4.36 / 183.82 2 7
Average= 4.18
(KJ/cycle)

Cycle 42 GMT 28/ 6/2020 19: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.56 31 15.30 512 243 0.24 / 175.53 2 2
2 7 2003.44 31 15.09 2974 1391 1.63 / 176.92 2 3
3 13 1591.24 18 15.09 2495 678 2.31 / 177.60 2 4
4 13 1022.00 18 15.16 1762 481 2.79 / 178.08 2 4
5 13 613.40 18 15.22 1245 341 3.13 / 178.42 2 5
6 13 169.92 18 15.33 613 169 3.30 / 178.59 2 4
7 8 0.08 165 15.34 344 871 4.17 / 179.46 2 4
Average= 4.17
(KJ/cycle)

Cycle 41 GMT 18/ 6/2020 20:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 31 15.31 514 244 0.24 / 171.23 2 2
2 7 2009.64 31 15.10 2969 1390 1.63 / 172.62 2 3
3 13 1594.36 18 15.10 2510 682 2.32 / 173.30 2 4
4 13 1033.84 18 15.16 1803 492 2.81 / 173.79 2 4
5 13 621.84 18 15.22 1258 345 3.15 / 174.13 2 5
6 13 195.00 18 15.33 646 178 3.33 / 174.31 2 4
7 13 15.20 18 15.37 372 103 3.43 / 174.42 2 2
8 8 0.24 165 15.33 346 875 4.31 / 175.29 2 5
Average= 4.17
(KJ/cycle)

Cycle 40 GMT 8/ 6/2020 22:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.08 31 15.31 522 248 0.25 / 166.96 2 2
2 3 1014.60 1 15.38 1824 28 0.28 / 166.99 2 3
3 7 2002.12 31 15.09 2979 1394 1.67 / 168.38 2 3
4 13 1588.52 18 15.10 2498 679 2.35 / 169.06 2 4
5 13 1150.60 18 15.14 1955 533 2.88 / 169.60 2 5
6 13 576.60 18 15.25 1200 329 3.21 / 169.92 2 5
7 13 149.88 18 15.34 601 166 3.38 / 170.09 2 4
8 8 0.08 165 15.34 352 891 4.27 / 170.98 2 6
Average= 4.17
(KJ/cycle)

Cycle 39 GMT 30/ 5/2020 0:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 30 15.31 538 247 0.25 / 162.77 2 2
2 7 2003.20 31 15.10 2970 1390 1.64 / 164.16 2 3
3 13 1582.28 18 15.10 2490 677 2.31 / 164.84 2 3
4 13 1020.00 18 15.17 1775 485 2.80 / 165.32 2 4
5 13 596.76 18 15.24 1224 336 3.13 / 165.66 2 5
6 13 157.60 18 15.34 611 169 3.30 / 165.83 2 5
7 8 0.12 165 15.34 351 888 4.19 / 166.71 2 3
Average= 4.17
(KJ/cycle)

Cycle 38 GMT 20/ 5/2020 2:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.00 30 15.31 539 248 0.25 / 158.56 2 3
2 7 2006.16 31 15.11 2977 1394 1.64 / 159.96 2 3
3 13 1590.64 18 15.11 2503 681 2.32 / 160.64 2 3
4 13 1046.08 18 15.17 1814 495 2.82 / 161.13 2 4
5 13 631.96 18 15.23 1275 350 3.17 / 161.48 2 5
6 13 98.08 18 15.36 511 141 3.31 / 161.62 2 3
7 8 0.08 165 15.35 355 899 4.21 / 162.52 2 3
Average= 4.17
(KJ/cycle)

Cycle 37 GMT 10/ 5/2020 4:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.44 30 15.31 534 245 0.25 / 154.25 2 3
2 3 1013.04 1 15.37 1821 28 0.27 / 154.28 2 3
3 7 2004.44 32 15.10 2978 1439 1.71 / 155.71 2 3
4 13 1587.44 18 15.11 2501 680 2.39 / 156.39 2 4
5 13 1043.92 18 15.17 1806 493 2.89 / 156.89 2 4
6 13 618.68 18 15.24 1251 343 3.23 / 157.23 2 5
7 13 166.48 18 15.34 631 174 3.40 / 157.41 2 5
8 8 0.08 165 15.35 359 909 4.31 / 158.31 2 3
Average= 4.17
(KJ/cycle)

Cycle 36 GMT 30/ 4/2020 6:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 30 15.32 519 239 0.24 / 150.00 2 2
2 7 2007.28 31 15.10 2991 1400 1.64 / 151.40 2 3
3 13 1583.00 18 15.12 2497 680 2.32 / 152.08 2 3
4 13 1143.92 18 15.15 1953 533 2.85 / 152.61 2 4
5 13 568.64 18 15.26 1186 326 3.18 / 152.94 2 5
6 13 149.44 18 15.35 605 167 3.34 / 153.10 2 4
7 8 0.12 165 15.35 355 899 4.24 / 154.00 2 4
Average= 4.16
(KJ/cycle)

Cycle 35 GMT 20/ 4/2020 8:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 30 15.32 520 239 0.24 / 145.85 2 2
2 7 2005.60 31 15.10 2993 1401 1.64 / 147.25 2 3
3 13 1486.40 18 15.12 2387 650 2.29 / 147.90 2 4
4 13 1063.88 18 15.17 1838 502 2.79 / 148.40 2 4
5 13 502.00 18 15.27 1105 304 3.10 / 148.71 2 5
6 13 113.24 18 15.36 542 150 3.25 / 148.86 2 4
7 8 0.16 165 15.35 356 902 4.15 / 149.76 2 3
Average= 4.16
(KJ/cycle)

Cycle 34 GMT 10/ 4/2020 10:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 30 15.32 524 241 0.24 / 141.49 2 3
2 7 2003.44 31 15.11 2980 1396 1.64 / 142.88 2 3
3 13 1593.76 18 15.11 2510 683 2.32 / 143.56 2 4
4 13 1017.36 18 15.18 1787 488 2.81 / 144.05 2 4
5 13 597.24 18 15.25 1232 338 3.15 / 144.39 2 5
6 13 157.48 18 15.35 607 168 3.31 / 144.56 2 5
7 8 0.08 165 15.36 352 892 4.21 / 145.45 2 5
8 14 0.08 30 15.33 352 162 4.37 / 145.61 2 2
Average= 4.16
(KJ/cycle)

Cycle 33 GMT 31/ 3/2020 12:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.40 30 15.33 535 246 0.25 / 137.24 2 2
2 7 2006.84 31 15.12 2987 1400 1.65 / 138.64 2 3
3 13 1594.40 18 15.12 2507 682 2.33 / 139.32 2 3
4 13 1037.28 18 15.18 1803 493 2.82 / 139.81 2 4
5 13 625.36 18 15.25 1261 346 3.17 / 140.16 2 5
6 13 183.36 18 15.35 660 182 3.35 / 140.34 2 4
7 8 0.24 165 15.36 356 902 4.25 / 141.24 2 5
Average= 4.15
(KJ/cycle)

Cycle 32 GMT 21/ 3/2020 14:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 30 15.33 520 239 0.24 / 132.95 2 2
2 7 2001.76 31 15.12 2980 1397 1.64 / 134.35 2 3
3 13 1717.68 18 15.11 2651 721 2.36 / 135.07 2 4
4 13 1114.00 18 15.18 1912 522 2.88 / 135.59 2 4
5 13 571.76 18 15.27 1193 328 3.21 / 135.92 2 5
6 13 153.08 18 15.37 606 168 3.37 / 136.09 2 4
7 8 -0.20 165 15.37 356 903 4.28 / 136.99 2 2
Average= 4.15
(KJ/cycle)

Cycle 31 GMT 11/ 3/2020 16:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.60 30 15.33 524 241 0.24 / 128.76 2 3
2 7 2005.24 31 15.12 2989 1401 1.64 / 130.16 2 3
3 13 1574.00 18 15.13 2482 676 2.32 / 130.84 2 4
4 13 998.44 18 15.20 1759 481 2.80 / 131.32 2 5
5 13 574.32 18 15.27 1201 330 3.13 / 131.65 2 5
6 13 132.16 18 15.37 576 159 3.29 / 131.81 2 4
7 8 0.08 165 15.37 357 905 4.19 / 132.72 2 3
Average= 4.15
(KJ/cycle)

Cycle 30 GMT 1/ 3/2020 18:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 30 15.33 529 243 0.24 / 124.57 2 2
2 7 2001.96 31 15.13 2979 1397 1.64 / 125.97 2 3
3 13 1470.00 18 15.15 2357 643 2.28 / 126.61 2 4
4 13 1047.80 18 15.19 1814 496 2.78 / 127.11 2 5
5 13 609.76 18 15.27 1242 341 3.12 / 127.45 2 5
6 13 170.56 18 15.36 631 174 3.30 / 127.63 2 4
7 8 0.16 165 15.37 353 895 4.19 / 128.52 2 5
Average= 4.15
(KJ/cycle)

Cycle 29 GMT 20/ 2/2020 20:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 30 15.34 529 243 0.24 / 120.38 2 2
2 7 2005.52 31 15.12 2977 1395 1.64 / 121.78 2 3
3 13 1585.36 18 15.13 2487 677 2.32 / 122.46 2 4
4 13 1025.48 18 15.20 1776 486 2.80 / 122.94 2 4
5 13 583.52 18 15.27 1203 331 3.13 / 123.27 2 5
6 13 151.96 18 15.37 586 162 3.29 / 123.44 2 5
7 8 0.08 165 15.37 353 895 4.19 / 124.33 2 3
Average= 4.14
(KJ/cycle)

Cycle 28 GMT 10/ 2/2020 22:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 30 15.34 523 241 0.24 / 116.19 2 3
2 7 2007.04 31 15.14 2994 1405 1.65 / 117.60 2 3
3 13 1596.80 18 15.14 2508 683 2.33 / 118.28 2 4
4 13 1033.00 18 15.20 1800 492 2.82 / 118.77 2 4
5 13 601.96 18 15.27 1228 338 3.16 / 119.11 2 5
6 13 92.04 18 15.40 499 138 3.30 / 119.25 2 4
7 8 0.04 165 15.38 352 893 4.19 / 120.14 2 5
Average= 4.14
(KJ/cycle)

Cycle 27 GMT 1/ 2/2020 0: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 30 15.35 535 246 0.25 / 112.00 2 2
2 7 2002.64 31 15.14 2982 1400 1.65 / 113.40 2 3
3 13 1579.40 18 15.15 2479 676 2.32 / 114.07 2 4
4 13 1026.48 18 15.21 1781 488 2.81 / 114.56 2 4
5 13 614.72 18 15.27 1250 344 3.15 / 114.90 2 5
6 13 100.44 18 15.40 520 144 3.30 / 115.05 2 4
7 8 0.24 165 15.38 356 903 4.20 / 115.95 2 3
Average= 4.14
(KJ/cycle)

Cycle 26 GMT 22/ 1/2020 1:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.36 30 15.35 526 242 0.24 / 107.70 2 2
2 7 2003.68 31 15.13 2999 1407 1.65 / 109.11 2 3
3 13 1729.28 18 15.12 2694 733 2.38 / 109.84 2 3
4 13 1122.28 18 15.19 1926 527 2.91 / 110.37 2 5
5 13 550.76 18 15.30 1160 319 3.23 / 110.69 2 5
6 13 129.80 18 15.39 563 156 3.38 / 110.84 2 5
7 8 0.04 165 15.38 357 906 4.29 / 111.75 2 3
Average= 4.14
(KJ/cycle)

Cycle 25 GMT 12/ 1/2020 3:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.76 30 15.35 526 242 0.24 / 103.43 2 2
2 7 2004.24 32 15.14 2994 1451 1.69 / 104.88 2 3
3 13 1582.72 18 15.15 2500 682 2.37 / 105.56 2 3
4 13 1018.52 18 15.22 1782 488 2.86 / 106.05 2 4
5 13 597.40 18 15.29 1227 338 3.20 / 106.39 2 5
6 13 151.44 18 15.39 595 165 3.37 / 106.55 2 4
7 8 -0.04 165 15.38 358 908 4.27 / 107.46 2 3
Average= 4.13
(KJ/cycle)

Cycle 24 GMT 2/ 1/2020 5:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.20 30 15.36 501 231 0.23 / 99.16 2 2
2 7 2006.00 31 15.14 2990 1403 1.63 / 100.56 2 3
3 13 1602.32 18 15.15 2528 689 2.32 / 101.25 2 3
4 13 1161.80 18 15.19 1964 537 2.86 / 101.79 2 4
5 13 584.52 18 15.29 1219 335 3.20 / 102.12 2 5
6 13 149.36 18 15.39 592 164 3.36 / 102.29 2 4
7 8 0.16 165 15.39 354 899 4.26 / 103.19 2 3
Average= 4.13
(KJ/cycle)

Cycle 23 GMT 23/12/2019 7:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 30 15.36 523 241 0.24 / 94.75 2 2
2 7 2003.44 31 15.15 2986 1402 1.64 / 96.15 2 3
3 13 1583.88 18 15.16 2495 681 2.32 / 96.84 2 4
4 13 1044.80 18 15.22 1814 497 2.82 / 97.33 2 5
5 13 612.92 18 15.29 1244 342 3.16 / 97.67 2 5
6 13 180.72 18 15.39 641 178 3.34 / 97.85 2 4
7 8 -0.12 165 15.39 358 909 4.25 / 98.76 2 4
8 14 -0.12 30 15.37 358 165 4.42 / 98.93 2 5
Average= 4.12
(KJ/cycle)

Cycle 22 GMT 13/12/2019 9:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 30 15.37 520 240 0.24 / 90.57 2 2
2 7 2003.12 31 15.14 2996 1406 1.65 / 91.98 2 3
3 13 1585.00 18 15.16 2506 684 2.33 / 92.66 2 3
4 13 1011.16 18 15.22 1777 487 2.82 / 93.15 2 4
5 13 582.56 18 15.30 1216 335 3.15 / 93.48 2 5
6 13 78.56 18 15.42 478 133 3.28 / 93.62 2 4
7 8 0.08 165 15.40 352 894 4.18 / 94.51 2 4
Average= 4.11
(KJ/cycle)

Cycle 21 GMT 3/12/2019 10:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.92 30 15.36 537 247 0.25 / 86.13 2 2
2 3 1013.56 1 15.43 1835 28 0.28 / 86.16 2 3
3 7 2005.88 31 15.15 3001 1409 1.69 / 87.56 2 3
4 13 1586.36 18 15.16 2510 685 2.37 / 88.25 2 3
5 13 1041.40 18 15.23 1810 496 2.87 / 88.75 2 4
6 13 616.04 18 15.29 1252 345 3.21 / 89.09 2 5
7 13 93.64 18 15.41 517 143 3.35 / 89.23 2 4
8 8 0.08 165 15.40 366 930 4.28 / 90.16 2 4
9 14 0.08 30 15.38 366 169 4.45 / 90.33 2 5
Average= 4.11
(KJ/cycle)

Cycle 20 GMT 23/11/2019 12:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.56 30 15.38 504 233 0.23 / 81.91 2 2
2 7 2008.20 31 15.16 2976 1399 1.63 / 83.31 2 3
3 13 1583.40 18 15.17 2490 680 2.31 / 83.99 2 4
4 13 1014.56 18 15.23 1772 486 2.80 / 84.48 2 4
5 13 582.12 18 15.31 1201 331 3.13 / 84.81 2 5
6 13 84.96 18 15.42 506 140 3.27 / 84.95 2 3
7 8 0.24 165 15.40 367 933 4.20 / 85.88 2 3
Average= 4.09
(KJ/cycle)

Cycle 19 GMT 13/11/2019 14:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 30 15.37 510 235 0.24 / 77.71 2 2
2 7 2002.84 31 15.16 2978 1400 1.63 / 79.11 2 3
3 13 1581.08 18 15.18 2487 680 2.31 / 79.79 2 3
4 13 1021.12 18 15.24 1774 487 2.80 / 80.28 2 4
5 13 604.60 18 15.30 1228 338 3.14 / 80.62 2 5
6 13 162.56 18 15.40 604 167 3.31 / 80.79 2 4
7 8 -0.08 165 15.41 351 892 4.20 / 81.68 2 4
Average= 4.08
(KJ/cycle)

Cycle 18 GMT 3/11/2019 16: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 30 15.38 505 233 0.23 / 73.42 2 3
2 7 2006.92 31 15.15 2993 1406 1.64 / 74.83 2 3
3 13 1589.76 18 15.17 2499 682 2.32 / 75.51 2 4
4 13 910.80 18 15.26 1630 448 2.77 / 75.96 2 4
5 13 510.88 18 15.33 1108 306 3.07 / 76.27 2 5
6 13 107.08 18 15.42 530 147 3.22 / 76.41 2 4
7 8 0.00 165 15.41 355 903 4.12 / 77.31 2 5
8 14 0.00 30 15.39 357 165 4.29 / 77.48 2 3
Average= 4.08
(KJ/cycle)

Cycle 17 GMT 24/10/2019 17:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 30 15.38 500 231 0.23 / 69.06 2 2
2 7 2002.72 32 15.16 2995 1453 1.68 / 70.51 2 3
3 13 1588.84 18 15.18 2496 682 2.37 / 71.20 2 3
4 13 1022.76 18 15.24 1784 489 2.86 / 71.69 2 4
5 13 486.16 18 15.34 1069 295 3.15 / 71.98 2 4
6 13 101.60 18 15.43 515 143 3.29 / 72.12 2 3
7 8 0.12 165 15.41 355 903 4.20 / 73.03 2 3
8 14 0.12 30 15.39 355 164 4.36 / 73.19 2 3
Average= 4.07
(KJ/cycle)

Cycle 16 GMT 14/10/2019 19:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 30 15.38 493 227 0.23 / 64.82 2 2
2 7 2001.48 31 15.16 2987 1404 1.63 / 66.22 2 3
3 13 1714.60 18 15.17 2656 725 2.36 / 66.95 2 3
4 13 996.00 18 15.25 1742 478 2.83 / 67.43 2 4
5 13 585.92 18 15.32 1200 331 3.17 / 67.76 2 4
6 13 140.64 18 15.42 591 164 3.33 / 67.92 2 4
7 8 -0.04 165 15.41 357 908 4.24 / 68.83 2 5
Average= 4.05
(KJ/cycle)

Cycle 15 GMT 4/10/2019 21: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 30 15.38 499 230 0.23 / 60.51 2 2
2 7 2003.80 31 15.17 2990 1406 1.64 / 61.92 2 3
3 13 1591.08 18 15.19 2498 683 2.32 / 62.60 2 3
4 13 1033.76 18 15.25 1799 494 2.81 / 63.09 2 4
5 13 613.48 18 15.31 1245 343 3.16 / 63.44 2 5
6 13 95.56 18 15.43 512 142 3.30 / 63.58 2 3
7 13 21.24 18 15.44 388 108 3.41 / 63.69 2 2
8 8 0.08 165 15.41 357 908 4.31 / 64.59 2 8
Average= 4.04
(KJ/cycle)

Cycle 14 GMT 24/ 9/2019 22:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.60 30 15.39 506 234 0.23 / 56.20 2 3
2 7 2001.76 31 15.18 2998 1411 1.64 / 57.61 2 3
3 13 1581.56 18 15.19 2493 682 2.33 / 58.29 2 3
4 13 1011.64 18 15.26 1767 485 2.81 / 58.78 2 4
5 13 578.32 18 15.32 1195 330 3.14 / 59.11 2 5
6 13 145.40 18 15.42 583 162 3.30 / 59.27 2 4
7 13 26.44 18 15.44 392 109 3.41 / 59.38 2 2
8 8 0.04 165 15.41 354 900 4.31 / 60.28 2 3
Average= 4.02
(KJ/cycle)

Cycle 13 GMT 15/ 9/2019 0:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.68 30 15.39 521 241 0.24 / 51.90 2 2
2 7 2004.20 32 15.17 2997 1455 1.70 / 53.35 2 3
3 13 1461.24 18 15.21 2353 644 2.34 / 54.00 2 4
4 13 1038.96 18 15.25 1794 492 2.83 / 54.49 2 4
5 13 602.24 18 15.32 1228 339 3.17 / 54.83 2 5
6 13 78.40 18 15.44 478 133 3.30 / 54.96 2 4
7 13 20.28 18 15.45 384 107 3.41 / 55.07 2 2
8 8 0.04 165 15.42 354 901 4.31 / 55.97 2 3
Average= 4.00
(KJ/cycle)

Cycle 12 GMT 5/ 9/2019 2:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.96 30 15.38 525 242 0.24 / 47.57 2 2
2 7 2005.00 31 15.19 2987 1407 1.65 / 48.98 2 3
3 13 1592.64 18 15.19 2505 685 2.33 / 49.66 2 3
4 13 1018.76 18 15.26 1783 490 2.82 / 50.15 2 4
5 13 578.40 18 15.33 1213 335 3.16 / 50.48 2 5
6 13 70.64 18 15.45 477 133 3.29 / 50.62 2 3
7 13 20.32 18 15.45 397 110 3.40 / 50.73 2 2
8 8 0.12 165 15.42 365 929 4.33 / 51.66 2 4
Average= 3.97
(KJ/cycle)

Cycle 11 GMT 26/ 8/2019 4: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.24 30 15.39 517 239 0.24 / 43.21 2 3
2 7 2003.40 31 15.18 2997 1410 1.65 / 44.62 2 3
3 13 1590.60 18 15.20 2511 687 2.34 / 45.31 2 3
4 13 1017.48 18 15.26 1782 489 2.83 / 45.79 2 4
5 13 588.16 18 15.32 1222 337 3.16 / 46.13 2 5
6 13 132.96 18 15.43 581 161 3.32 / 46.29 2 4
7 13 13.44 18 15.45 388 108 3.43 / 46.40 2 2
8 8 0.00 165 15.41 364 926 4.36 / 47.33 2 3
Average= 3.94
(KJ/cycle)

Cycle 10 GMT 16/ 8/2019 5:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 29 15.39 526 235 0.23 / 38.87 2 2
2 7 2008.72 31 15.19 3000 1413 1.65 / 40.28 2 3
3 13 1586.96 18 15.21 2505 686 2.33 / 40.97 2 3
4 13 1028.36 18 15.26 1791 492 2.83 / 41.46 2 5
5 13 605.64 18 15.32 1236 341 3.17 / 41.80 2 5
6 13 78.28 18 15.44 485 135 3.30 / 41.94 2 3
7 13 19.04 18 15.45 395 110 3.41 / 42.05 2 2
8 8 0.12 165 15.42 363 924 4.33 / 42.97 2 5
Average= 3.91
(KJ/cycle)

Cycle 9 GMT 6/ 8/2019 7:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 29 15.39 495 221 0.22 / 34.56 2 2
2 7 2003.80 31 15.19 2989 1407 1.63 / 35.97 2 3
3 13 1578.20 18 15.21 2495 683 2.31 / 36.65 2 4
4 13 1000.36 18 15.27 1772 487 2.80 / 37.14 2 5
5 13 573.96 18 15.33 1208 333 3.13 / 37.47 2 5
6 13 74.96 18 15.45 480 133 3.27 / 37.61 2 3
7 13 15.52 18 15.46 386 107 3.37 / 37.71 2 2
8 8 0.00 165 15.42 362 921 4.29 / 38.64 2 7
Average= 3.86
(KJ/cycle)

Cycle 8 GMT 27/ 7/2019 9:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 29 15.39 520 232 0.23 / 30.27 2 2
2 7 2001.32 30 15.20 2975 1357 1.59 / 31.63 2 3
3 13 1579.52 17 15.21 2486 643 2.23 / 32.27 2 4
4 13 1135.40 17 15.25 1927 500 2.73 / 32.77 2 5
5 13 693.96 17 15.31 1363 355 3.09 / 33.12 2 6
6 13 249.44 17 15.41 745 195 3.28 / 33.32 2 5
7 13 20.80 17 15.46 391 103 3.38 / 33.42 2 2
8 8 0.04 165 15.42 362 921 4.30 / 34.34 2 3
Average= 3.82
(KJ/cycle)

Cycle 7 GMT 17/ 7/2019 11: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 29 15.39 533 238 0.24 / 25.90 2 2
2 3 1012.64 1 15.46 1835 28 0.27 / 25.93 2 3
3 7 2001.52 30 15.21 2983 1361 1.63 / 27.29 2 3
4 13 1587.40 17 15.22 2505 648 2.28 / 27.94 2 4
5 13 1157.28 17 15.25 1951 506 2.78 / 28.44 2 5
6 13 707.20 17 15.31 1370 357 3.14 / 28.80 2 5
7 13 260.60 17 15.41 761 199 3.34 / 29.00 2 5
8 13 20.56 17 15.46 393 103 3.44 / 29.10 2 2
9 8 0.08 165 15.42 368 936 4.38 / 30.04 2 6
Average= 3.75
(KJ/cycle)

Cycle 6 GMT 7/ 7/2019 12:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 31 15.39 509 243 0.24 / 21.66 2 2
2 3 950.96 -1 15.70 12 0 0.00 / 21.66 2 2
3 7 2005.56 31 15.21 3004 1416 1.66 / 23.07 2 3
4 13 1587.84 18 15.22 2506 687 2.35 / 23.76 2 4
5 13 1014.52 18 15.28 1774 488 2.83 / 24.25 2 5
6 13 580.68 18 15.34 1210 334 3.17 / 24.58 2 6
7 13 77.44 18 15.45 493 137 3.30 / 24.72 2 4
8 8 0.36 165 15.43 369 939 4.24 / 25.66 2 3
Average= 3.67
(KJ/cycle)

Cycle 5 GMT 27/ 6/2019 14:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 23 15.40 530 188 0.19 / 17.32 2 2
2 10 1014.04 5 15.37 1803 139 0.33 / 17.45 2 2
3 3 1020.28 1 15.44 1837 28 0.35 / 17.48 2 3
4 7 2003.08 30 15.21 2971 1356 1.71 / 18.84 2 3
5 13 1575.64 18 15.23 2468 677 2.39 / 19.51 2 4
6 13 1017.04 18 15.28 1769 487 2.87 / 20.00 2 5
7 13 581.20 18 15.34 1202 332 3.21 / 20.33 2 6
8 13 134.04 18 15.44 570 158 3.36 / 20.49 2 4
9 8 0.00 165 15.43 363 924 4.29 / 21.42 2 3
Average= 3.57
(KJ/cycle)

Cycle 4 GMT 17/ 6/2019 16:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.16 29 15.40 531 237 0.24 / 13.68 2 2
2 7 1517.44 38 15.27 2382 1382 1.62 / 15.06 2 3
3 13 1253.28 18 15.28 2073 570 2.19 / 15.63 2 3
4 13 689.40 18 15.34 1341 370 2.56 / 16.00 2 4
5 13 266.80 18 15.42 767 213 2.77 / 16.21 2 4
6 8 0.16 165 15.44 359 915 3.69 / 17.13 2 3
Average= 3.43
(KJ/cycle)

Cycle 3 GMT 16/ 6/2019 16: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 27 15.40 530 220 0.22 / 9.51 2 3
2 3 1026.40 1 15.45 1856 29 0.25 / 9.54 2 3
3 7 1506.28 74 15.19 2351 2643 2.89 / 12.18 2 3
4 13 310.56 18 15.42 822 228 3.12 / 12.41 2 4
5 13 33.08 18 15.47 402 112 3.23 / 12.52 2 2
6 8 0.12 165 15.44 362 922 4.15 / 13.44 2 2
Average= 3.36
(KJ/cycle)

Cycle 2 GMT 15/ 6/2019 16:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.64 24 15.43 542 201 0.20 / 5.30 2 2
2 10 1032.56 2 15.39 1837 57 0.26 / 5.36 2 2
3 3 1036.24 1 15.45 1874 29 0.29 / 5.39 2 3
4 7 1525.28 74 15.19 2366 2660 2.95 / 8.05 2 3
5 13 309.92 18 15.42 813 226 3.17 / 8.27 2 4
6 13 18.04 18 15.48 380 106 3.28 / 8.38 2 2
7 8 0.28 165 15.44 357 909 4.19 / 9.29 2 2
Average= 3.10
(KJ/cycle)

Cycle 1 GMT 14/ 6/2019 16:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.08 23 15.60 468 168 0.17 / 2.03 2 3
2 10 1018.60 4 15.44 1778 110 0.28 / 2.14 2 2
3 3 1057.32 2 15.45 1883 58 0.34 / 2.20 2 2
4 3 1020.64 1 15.48 1828 28 0.36 / 2.23 2 2
5 7 999.92 74 15.32 1708 1936 2.30 / 4.16 2 4
6 8 0.08 165 15.48 366 935 3.24 / 5.10 2 4
Average= 2.55
(KJ/cycle)

Cycle 0 GMT 14/ 6/2019 6:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 124.40 22 15.74 489 169 0.17 / 0.17 3 3
2 7 138.36 74 15.71 491 571 0.74 / 0.74 3 3
3 8 0.24 240 15.66 299 1124 1.86 / 1.86 2 7
Average= 1.86
(KJ/cycle)