SIO Argo Site:
Pump Diagnostics Page   



Serial= 7524 WMO= 3902144

Return

←PreviousNext→

Cycle 190 GMT 9/ 5/2024 0:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 31 14.82 501 230 0.23 / 1052.20 5 30
2 10 1014.84 3 14.84 1887 84 0.31 / 1052.29 5 66
3 7 2009.08 40 14.44 3256 1881 2.19 / 1054.17 66 70
4 13 1920.80 20 14.43 3145 908 3.10 / 1055.08 5 77
5 13 1601.84 20 14.41 2714 782 3.88 / 1055.86 5 85
6 13 1047.00 20 14.50 1938 562 4.45 / 1056.42 5 96
7 13 250.48 20 14.77 751 222 4.67 / 1056.64 5 98
8 8 0.04 267 14.81 338 1337 6.01 / 1057.98 5 138
Average= 15.33
(KJ/cycle)

Cycle 189 GMT 29/ 4/2024 3:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 31 14.90 493 228 0.23 / 1045.89 5 32
2 7 2007.24 40 14.41 3243 1869 2.10 / 1047.76 32 71
3 13 1926.36 20 14.40 3152 908 3.00 / 1048.66 5 76
4 13 1500.92 20 14.41 2549 735 3.74 / 1049.40 5 87
5 13 1057.52 20 14.53 1766 513 4.25 / 1049.91 5 98
6 13 1057.52 20 14.54 1587 461 4.71 / 1050.37 5 100
7 13 1057.52 20 14.56 1372 400 5.11 / 1050.77 5 100
8 8 0.08 247 14.82 328 1201 6.31 / 1051.97 5 129
Average= 15.47
(KJ/cycle)

Cycle 188 GMT 19/ 4/2024 7:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 32 14.80 499 236 0.24 / 1040.44 5 34
2 3 934.12 -1 15.27 0 0 0.00 / 1040.44 5 34
3 7 2014.48 40 14.44 3260 1883 2.12 / 1042.33 34 71
4 13 1724.92 20 14.50 2868 832 2.95 / 1043.16 5 82
5 13 1270.52 20 14.59 2234 652 3.60 / 1043.81 5 93
6 13 769.84 20 14.74 1506 444 4.05 / 1044.25 5 97
7 13 133.44 20 14.99 535 160 4.21 / 1044.41 5 95
8 8 0.08 265 14.97 314 1246 5.45 / 1045.66 5 132
Average= 15.61
(KJ/cycle)

Cycle 187 GMT 9/ 4/2024 9:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 33 14.92 499 246 0.25 / 1034.25 5 32
2 7 2007.60 40 14.42 3260 1880 2.13 / 1036.13 32 68
3 13 1816.48 20 14.46 3007 870 3.00 / 1037.00 5 79
4 13 1329.68 20 14.56 2317 675 3.67 / 1037.67 5 89
5 13 716.32 20 14.72 1455 428 4.10 / 1038.10 5 97
6 13 622.28 20 14.72 1274 375 4.47 / 1038.48 5 100
7 13 622.28 20 14.75 1059 312 4.79 / 1038.79 5 102
8 13 622.28 20 14.78 812 240 5.03 / 1039.03 5 107
9 13 622.28 20 14.83 546 162 5.19 / 1039.19 5 103
10 8 0.04 211 14.83 324 1014 6.20 / 1040.21 5 139
Average= 15.76
(KJ/cycle)

Cycle 186 GMT 30/ 3/2024 13: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 32 14.80 511 242 0.24 / 1028.93 5 32
2 7 2011.04 40 14.44 3254 1880 2.12 / 1030.81 32 72
3 13 1729.32 20 14.50 2859 829 2.95 / 1031.64 5 84
4 13 1078.24 20 14.67 1953 573 3.52 / 1032.21 5 95
5 13 692.04 20 14.79 1375 407 3.93 / 1032.62 5 99
6 13 100.00 20 15.02 469 141 4.07 / 1032.76 5 89
7 8 0.08 264 14.98 314 1242 5.31 / 1034.00 5 140
Average= 15.91
(KJ/cycle)

Cycle 185 GMT 20/ 3/2024 15:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 32 14.81 504 239 0.24 / 1022.26 5 34
2 7 2006.40 40 14.45 3246 1876 2.12 / 1024.13 34 70
3 13 1719.72 20 14.51 2846 826 2.94 / 1024.96 5 81
4 13 1247.60 20 14.58 2195 640 3.58 / 1025.60 5 91
5 13 1209.04 20 14.55 2061 600 4.18 / 1026.20 5 96
6 13 1209.04 20 14.55 1857 540 4.72 / 1026.74 5 99
7 13 1209.04 20 14.56 1626 473 5.19 / 1027.21 5 99
8 13 1209.04 20 14.58 1384 404 5.60 / 1027.62 5 105
9 8 0.04 223 14.83 325 1075 6.67 / 1028.69 5 134
Average= 16.07
(KJ/cycle)

Cycle 184 GMT 10/ 3/2024 18:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 32 14.79 506 239 0.24 / 1015.79 5 38
2 7 2008.88 40 14.44 3254 1880 2.12 / 1017.67 38 71
3 13 1731.84 20 14.50 2860 829 2.95 / 1018.50 5 82
4 13 1283.84 20 14.59 2249 656 3.60 / 1019.16 5 90
5 13 1010.28 20 14.64 1806 529 4.13 / 1019.69 5 97
6 13 1010.28 20 14.64 1623 475 4.61 / 1020.16 5 98
7 13 1010.28 20 14.65 1398 410 5.02 / 1020.57 5 103
8 13 1010.28 20 14.68 1163 341 5.36 / 1020.91 5 104
9 8 0.00 229 14.85 325 1105 6.46 / 1022.02 5 131
Average= 16.22
(KJ/cycle)

Cycle 183 GMT 29/ 2/2024 22:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 32 14.91 499 238 0.24 / 1009.42 5 31
2 7 2008.20 40 14.43 3260 1882 2.12 / 1011.30 31 71
3 13 1726.68 20 14.49 2869 831 2.95 / 1012.13 5 83
4 13 1352.60 20 14.55 2358 686 3.64 / 1012.82 5 91
5 13 1016.68 20 14.65 1740 510 4.15 / 1013.33 5 99
6 13 1016.68 20 14.64 1558 456 4.60 / 1013.79 5 100
7 13 784.36 20 14.71 1134 334 4.94 / 1014.12 5 103
8 13 784.36 20 14.74 899 265 5.20 / 1014.38 5 106
9 13 784.36 20 14.79 636 188 5.39 / 1014.57 5 106
10 8 -0.12 195 14.82 331 957 6.35 / 1015.53 5 130
11 14 -0.16 5 14.79 330 24 6.37 / 1015.55 22 112
Average= 16.38
(KJ/cycle)

Cycle 182 GMT 20/ 2/2024 1:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 32 14.80 507 240 0.24 / 1004.02 5 39
2 7 2011.00 40 14.44 3244 1874 2.11 / 1005.90 39 71
3 13 1823.16 20 14.47 2990 865 2.98 / 1006.76 5 80
4 13 1157.72 20 14.64 2065 605 3.58 / 1007.37 5 93
5 13 659.04 20 14.80 1337 396 3.98 / 1007.76 5 99
6 13 152.84 20 15.00 561 168 4.15 / 1007.93 5 93
7 8 0.16 261 14.97 320 1250 5.40 / 1009.18 5 133
Average= 16.54
(KJ/cycle)

Cycle 181 GMT 10/ 2/2024 4: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 31 14.80 516 237 0.24 / 997.58 5 33
2 3 1061.60 2 14.87 1975 59 0.30 / 997.64 5 53
3 7 2009.12 40 14.44 3265 1886 2.18 / 999.53 53 70
4 13 1833.40 20 14.47 3017 873 3.05 / 1000.40 5 80
5 13 1181.52 20 14.63 2109 617 3.67 / 1001.02 5 94
6 13 882.12 20 14.68 1674 491 4.16 / 1001.51 5 97
7 13 882.12 20 14.68 1513 444 4.61 / 1001.95 5 100
8 13 882.12 20 14.69 1301 382 4.99 / 1002.33 5 100
9 13 882.12 20 14.71 1071 315 5.30 / 1002.65 5 104
10 8 -0.04 223 14.84 343 1135 6.44 / 1003.78 5 129
Average= 16.73
(KJ/cycle)

Cycle 180 GMT 31/ 1/2024 7:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 32 14.92 488 233 0.23 / 991.28 5 32
2 3 950.04 -1 15.28 0 0 0.00 / 991.28 5 32
3 7 2005.24 40 14.42 3257 1879 2.11 / 993.16 32 69
4 13 1718.68 20 14.49 2868 831 2.94 / 993.99 5 81
5 13 1155.64 20 14.62 2077 607 3.55 / 994.60 5 92
6 13 941.36 20 14.68 1651 485 4.03 / 995.08 5 97
7 13 941.36 20 14.68 1469 431 4.47 / 995.51 5 98
8 13 941.36 20 14.69 1262 371 4.84 / 995.88 5 103
9 13 941.36 20 14.71 1026 302 5.14 / 996.19 5 105
10 8 -0.04 227 14.84 344 1159 6.30 / 997.34 5 130
Average= 16.90
(KJ/cycle)

Cycle 179 GMT 21/ 1/2024 10:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.76 32 14.92 507 242 0.24 / 985.82 5 31
2 7 2006.48 40 14.43 3255 1879 2.12 / 987.70 9 69
3 13 1830.40 20 14.46 3024 875 3.00 / 988.57 5 79
4 13 1266.08 20 14.59 2240 654 3.65 / 989.23 5 91
5 13 587.36 20 14.82 1257 373 4.02 / 989.60 5 97
6 13 114.96 20 15.01 505 152 4.17 / 989.75 5 85
7 8 0.04 263 14.98 329 1296 5.47 / 991.05 5 131
Average= 17.09
(KJ/cycle)

Cycle 178 GMT 11/ 1/2024 13: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 32 14.93 492 235 0.24 / 980.56 5 30
2 7 2012.20 40 14.43 3253 1878 2.11 / 982.43 30 69
3 13 1646.56 20 14.52 2752 799 2.91 / 983.23 5 82
4 13 1197.92 20 14.62 2115 618 3.53 / 983.85 5 93
5 13 520.16 20 14.85 1143 339 3.87 / 984.19 5 97
6 13 83.32 20 15.03 439 132 4.00 / 984.32 5 79
7 8 0.08 264 14.98 317 1254 5.26 / 985.58 5 131
Average= 17.29
(KJ/cycle)

Cycle 177 GMT 1/ 1/2024 15: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 32 14.93 505 241 0.24 / 975.17 5 31
2 7 2011.60 40 14.43 3250 1876 2.12 / 977.04 31 70
3 13 1732.40 20 14.50 2875 834 2.95 / 977.87 5 80
4 13 1268.76 20 14.60 2222 649 3.60 / 978.52 5 90
5 13 681.12 20 14.79 1378 408 4.01 / 978.93 5 97
6 13 99.64 20 15.03 471 142 4.15 / 979.07 5 84
7 8 0.12 263 14.98 317 1249 5.40 / 980.32 5 134
Average= 17.51
(KJ/cycle)

Cycle 176 GMT 22/12/2023 17:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 31 14.93 494 229 0.23 / 969.78 5 35
2 7 2005.36 40 14.43 3242 1871 2.10 / 971.65 13 69
3 13 1823.20 20 14.46 2999 867 2.97 / 972.52 5 78
4 13 1325.12 20 14.57 2309 673 3.64 / 973.19 5 91
5 13 538.80 20 14.85 1170 347 3.99 / 973.54 5 97
6 13 93.20 20 15.04 454 137 4.12 / 973.67 5 83
7 8 0.08 263 14.99 317 1250 5.37 / 974.92 5 132
Average= 17.73
(KJ/cycle)

Cycle 175 GMT 12/12/2023 19:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 31 14.92 499 231 0.23 / 964.35 5 32
2 7 2013.28 40 14.43 3263 1883 2.11 / 966.23 32 71
3 13 1818.76 20 14.47 2983 863 2.98 / 967.10 5 80
4 13 1328.32 20 14.57 2305 672 3.65 / 967.77 5 90
5 13 716.88 20 14.77 1423 420 4.07 / 968.19 5 99
6 13 125.56 20 15.02 519 156 4.23 / 968.34 5 87
7 8 0.08 257 14.99 313 1206 5.43 / 969.55 5 139
Average= 17.95
(KJ/cycle)

Cycle 174 GMT 2/12/2023 22:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 31 14.92 502 232 0.23 / 959.02 5 30
2 7 2004.32 40 14.43 3246 1874 2.11 / 960.89 30 71
3 13 1810.04 20 14.47 2974 861 2.97 / 961.75 5 80
4 13 1164.60 20 14.63 2069 605 3.57 / 962.36 5 93
5 13 671.36 20 14.79 1356 401 3.97 / 962.76 5 100
6 13 94.72 20 15.03 459 138 4.11 / 962.89 5 81
7 8 0.00 261 14.99 313 1225 5.34 / 964.12 5 130
Average= 18.19
(KJ/cycle)

Cycle 173 GMT 23/11/2023 1: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 30 14.93 511 229 0.23 / 953.56 5 30
2 10 1018.28 3 14.84 1871 83 0.31 / 953.64 5 66
3 3 962.72 -1 15.28 0 0 0.08 / 953.64 5 66
4 7 2007.16 40 14.43 3258 1881 2.19 / 955.52 66 70
5 13 1732.04 20 14.49 2879 834 3.03 / 956.36 5 81
6 13 1261.60 20 14.59 2224 649 3.68 / 957.01 5 90
7 13 575.24 20 14.83 1229 365 4.04 / 957.37 5 99
8 8 0.24 282 14.99 334 1412 5.45 / 958.78 5 134
Average= 18.44
(KJ/cycle)

Cycle 172 GMT 13/11/2023 3:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 30 14.93 482 216 0.22 / 948.23 5 37
2 7 2016.96 40 14.43 3279 1893 2.11 / 950.12 37 68
3 13 1738.36 20 14.49 2903 841 2.95 / 950.97 5 79
4 13 1188.56 20 14.62 2121 620 3.57 / 951.59 5 91
5 13 531.76 20 14.85 1177 350 3.92 / 951.94 5 99
6 8 0.16 276 15.00 337 1395 5.31 / 953.33 5 132
Average= 18.69
(KJ/cycle)

Cycle 171 GMT 3/11/2023 5:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 32 14.94 495 237 0.24 / 942.95 5 35
2 3 937.56 -1 15.29 0 0 0.00 / 942.95 5 35
3 7 2014.40 40 14.44 3250 1877 2.11 / 944.83 35 70
4 13 1836.44 20 14.46 3025 875 2.99 / 945.70 5 77
5 13 1172.76 20 14.63 2089 611 3.60 / 946.31 5 90
6 13 596.32 20 14.83 1251 371 3.97 / 946.68 5 100
7 13 114.52 20 15.03 502 151 4.12 / 946.84 5 88
8 8 0.04 250 14.99 315 1180 5.30 / 948.02 5 132
Average= 18.96
(KJ/cycle)

Cycle 170 GMT 24/10/2023 8:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 31 14.93 501 232 0.23 / 937.61 5 37
2 7 2003.84 40 14.43 3250 1876 2.11 / 939.49 37 70
3 13 1812.04 20 14.47 2992 866 2.97 / 940.35 5 78
4 13 1324.96 20 14.57 2308 673 3.65 / 941.03 5 91
5 13 540.88 20 14.85 1175 349 4.00 / 941.38 5 99
6 13 16.44 20 15.07 337 102 4.10 / 941.48 5 76
7 8 0.12 261 15.00 316 1237 5.33 / 942.71 5 129
Average= 19.24
(KJ/cycle)

Cycle 169 GMT 14/10/2023 10:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 31 14.93 504 233 0.23 / 932.21 5 37
2 7 2005.92 40 14.44 3254 1880 2.11 / 934.09 37 69
3 13 1725.32 20 14.50 2868 832 2.94 / 934.93 5 81
4 13 1253.52 20 14.60 2204 644 3.59 / 935.57 5 91
5 13 659.96 20 14.80 1354 401 3.99 / 935.97 5 100
6 13 91.80 20 15.04 460 138 4.13 / 936.11 5 83
7 8 -0.04 266 14.99 319 1272 5.40 / 937.38 5 131
Average= 19.53
(KJ/cycle)

Cycle 168 GMT 4/10/2023 13:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 30 14.94 496 222 0.22 / 926.83 5 33
2 3 1045.64 1 14.92 1938 29 0.25 / 926.86 5 46
3 7 2003.48 40 14.44 3250 1877 2.13 / 928.74 46 69
4 13 1809.44 20 14.48 2975 862 2.99 / 929.60 5 80
5 13 1229.80 20 14.61 2176 636 3.63 / 930.24 5 90
6 13 560.88 20 14.85 1198 356 3.98 / 930.59 5 98
7 13 93.88 20 15.04 456 137 4.12 / 930.73 5 85
8 8 0.08 263 15.00 317 1251 5.37 / 931.98 5 131
Average= 19.83
(KJ/cycle)

Cycle 167 GMT 24/ 9/2023 15:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 31 14.93 495 229 0.23 / 921.47 5 34
2 3 935.12 -1 15.29 0 0 0.00 / 921.47 5 34
3 7 2008.80 40 14.43 3258 1881 2.11 / 923.35 34 70
4 13 1820.36 20 14.47 2999 868 2.98 / 924.22 5 79
5 13 1248.40 20 14.60 2205 644 3.62 / 924.86 5 91
6 13 555.40 20 14.84 1197 355 3.98 / 925.22 5 99
7 13 92.08 20 15.04 456 137 4.11 / 925.35 5 85
8 8 0.04 266 15.00 315 1257 5.37 / 926.61 5 130
Average= 20.14
(KJ/cycle)

Cycle 166 GMT 14/ 9/2023 18:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 31 14.92 518 240 0.24 / 916.05 5 34
2 7 2003.96 40 14.44 3262 1884 2.12 / 917.94 34 70
3 13 1812.12 20 14.48 2984 864 2.99 / 918.80 5 79
4 13 1235.20 20 14.61 2191 640 3.63 / 919.44 5 93
5 13 655.36 20 14.80 1341 397 4.03 / 919.84 5 98
6 13 94.20 20 15.04 462 139 4.16 / 919.98 5 87
7 8 0.16 263 14.99 320 1262 5.43 / 921.24 5 137
Average= 20.47
(KJ/cycle)

Cycle 165 GMT 4/ 9/2023 20:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 32 14.93 504 241 0.24 / 910.62 5 31
2 7 2011.64 40 14.44 3247 1875 2.12 / 912.50 31 71
3 13 1810.84 20 14.48 2981 863 2.98 / 913.36 5 80
4 13 1310.84 20 14.58 2296 670 3.65 / 914.03 5 90
5 13 526.48 20 14.86 1163 346 3.99 / 914.37 5 100
6 13 43.36 20 15.06 374 113 4.11 / 914.49 5 80
7 8 0.04 263 14.99 337 1329 5.44 / 915.82 5 145
Average= 20.81
(KJ/cycle)

Cycle 164 GMT 25/ 8/2023 23:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 31 14.93 502 232 0.23 / 905.18 5 36
2 7 2005.96 40 14.43 3257 1880 2.11 / 907.06 36 72
3 13 1907.36 20 14.45 3113 900 3.01 / 907.96 5 78
4 13 1218.12 20 14.62 2161 632 3.64 / 908.59 5 94
5 13 613.52 20 14.82 1283 380 4.02 / 908.97 5 101
6 8 0.16 282 15.00 333 1409 5.43 / 910.38 5 131
Average= 21.17
(KJ/cycle)

Cycle 163 GMT 16/ 8/2023 1:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 31 14.93 507 235 0.23 / 899.50 5 34
2 7 2012.20 40 14.44 3272 1890 2.12 / 901.39 13 71
3 13 1829.32 20 14.47 3016 873 3.00 / 902.26 5 80
4 13 1445.36 20 14.53 2478 720 3.72 / 902.98 5 91
5 13 740.84 20 14.77 1472 435 4.15 / 903.42 5 99
6 13 149.08 20 15.01 573 172 4.32 / 903.59 5 92
7 8 0.12 266 14.99 340 1356 5.68 / 904.95 5 133
Average= 21.55
(KJ/cycle)

Cycle 162 GMT 6/ 8/2023 4: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 32 14.93 499 238 0.24 / 894.01 5 39
2 7 2008.88 40 14.44 3255 1880 2.12 / 895.89 39 71
3 13 1818.64 20 14.48 2991 866 2.98 / 896.76 5 81
4 13 1352.92 20 14.57 2347 684 3.67 / 897.44 5 90
5 13 574.92 20 14.85 1222 363 4.03 / 897.80 5 98
6 13 174.52 20 15.00 603 181 4.21 / 897.99 5 95
7 8 0.00 263 14.99 325 1281 5.49 / 899.27 5 134
Average= 21.93
(KJ/cycle)

Cycle 161 GMT 27/ 7/2023 6:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 32 14.93 506 242 0.24 / 888.54 5 33
2 7 2005.56 40 14.45 3253 1880 2.12 / 890.42 33 70
3 13 1813.52 20 14.49 2985 865 2.99 / 891.28 5 80
4 13 1220.28 20 14.62 2165 633 3.62 / 891.92 5 94
5 13 714.72 20 14.78 1428 422 4.04 / 892.34 5 98
6 13 184.92 20 14.99 624 187 4.23 / 892.53 5 94
7 8 0.12 259 14.99 321 1246 5.48 / 893.77 5 129
Average= 22.34
(KJ/cycle)

Cycle 160 GMT 17/ 7/2023 9:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 30 14.93 507 227 0.23 / 883.04 5 32
2 3 1050.44 1 14.91 1960 29 0.26 / 883.07 5 50
3 7 2012.96 40 14.44 3264 1885 2.14 / 884.95 50 69
4 13 1826.52 20 14.48 3014 873 3.01 / 885.83 5 78
5 13 1251.24 20 14.61 2210 646 3.66 / 886.47 5 93
6 13 570.40 20 14.85 1219 362 4.02 / 886.83 5 99
7 13 182.76 20 15.01 617 185 4.21 / 887.02 5 94
8 8 0.04 265 14.99 322 1279 5.49 / 888.30 5 132
Average= 22.78
(KJ/cycle)

Cycle 159 GMT 7/ 7/2023 11:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 32 14.94 487 233 0.23 / 877.73 5 34
2 3 924.44 -1 15.29 0 0 0.00 / 877.73 5 34
3 7 2016.00 40 14.45 3257 1883 2.12 / 879.61 34 70
4 13 1645.20 20 14.53 2756 801 2.92 / 880.42 5 83
5 13 1210.80 20 14.63 2148 629 3.54 / 881.04 5 94
6 13 546.96 20 14.86 1189 353 3.90 / 881.40 5 97
7 13 145.96 20 15.02 552 166 4.06 / 881.56 5 94
8 8 0.08 261 14.99 319 1248 5.31 / 882.81 5 133
Average= 23.23
(KJ/cycle)

Cycle 158 GMT 27/ 6/2023 13:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 32 14.94 495 237 0.24 / 872.33 5 35
2 3 1021.44 1 14.99 1905 29 0.27 / 872.35 5 20
3 7 2014.44 40 14.45 3261 1885 2.15 / 874.24 20 70
4 13 1732.40 20 14.50 2901 841 2.99 / 875.08 5 78
5 13 1263.28 20 14.60 2227 650 3.64 / 875.73 5 93
6 13 569.32 20 14.84 1232 366 4.01 / 876.10 5 99
7 13 62.88 20 15.06 427 129 4.14 / 876.23 5 82
8 8 0.16 255 15.00 333 1274 5.41 / 877.50 5 129
Average= 23.72
(KJ/cycle)

Cycle 157 GMT 17/ 6/2023 16:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 30 14.95 499 224 0.22 / 866.97 5 30
2 3 1049.84 1 14.91 1956 29 0.25 / 867.00 5 55
3 7 2003.04 40 14.46 3228 1867 2.12 / 868.87 55 70
4 13 1719.16 20 14.51 2855 829 2.95 / 869.70 5 82
5 13 1260.00 20 14.61 2228 651 3.60 / 870.35 5 92
6 13 581.92 20 14.85 1227 364 3.96 / 870.71 5 99
7 13 40.96 20 15.06 397 120 4.08 / 870.83 5 80
8 8 0.12 263 15.00 319 1258 5.34 / 872.09 5 135
Average= 24.22
(KJ/cycle)

Cycle 156 GMT 7/ 6/2023 18:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 32 14.93 486 232 0.23 / 861.76 5 30
2 3 944.92 -1 15.29 0 0 0.00 / 861.76 5 30
3 7 2006.36 40 14.44 3252 1878 2.11 / 863.63 30 71
4 13 1808.04 20 14.48 2980 863 2.97 / 864.50 5 78
5 13 1056.44 20 14.69 1931 567 3.54 / 865.07 5 93
6 13 593.68 20 14.84 1252 372 3.91 / 865.44 5 100
7 13 22.96 20 15.06 357 108 4.02 / 865.54 5 81
8 8 0.08 253 15.00 317 1203 5.22 / 866.75 5 135
Average= 24.76
(KJ/cycle)

Cycle 155 GMT 28/ 5/2023 20:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 32 14.95 489 234 0.23 / 856.35 5 29
2 7 2005.52 40 14.45 3242 1874 2.11 / 858.23 29 69
3 13 1816.04 20 14.49 2995 868 2.98 / 859.09 5 79
4 13 1322.44 20 14.59 2294 669 3.65 / 859.76 5 92
5 13 541.76 20 14.86 1167 347 3.99 / 860.11 5 98
6 13 151.12 20 15.02 549 165 4.16 / 860.28 5 93
7 8 0.00 266 15.00 313 1249 5.41 / 861.52 5 135
Average= 25.34
(KJ/cycle)

Cycle 154 GMT 18/ 5/2023 23:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 32 14.87 510 243 0.24 / 850.97 5 30
2 7 2003.56 40 14.45 3243 1874 2.12 / 852.85 30 70
3 13 1810.20 20 14.49 2979 863 2.98 / 853.71 5 80
4 13 1241.60 20 14.62 2190 640 3.62 / 854.35 5 92
5 13 647.76 20 14.82 1332 395 4.02 / 854.74 5 99
6 13 55.24 20 15.06 408 123 4.14 / 854.87 5 83
7 13 29.00 20 15.06 348 105 4.24 / 854.97 5 80
8 8 0.12 242 15.00 316 1147 5.39 / 856.12 5 133
Average= 25.94
(KJ/cycle)

Cycle 153 GMT 9/ 5/2023 1:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.08 32 14.94 509 243 0.24 / 845.32 5 27
2 7 2003.76 40 14.45 3243 1874 2.12 / 847.19 27 69
3 13 1725.52 20 14.51 2883 837 2.95 / 848.03 5 81
4 13 1248.04 20 14.61 2216 648 3.60 / 848.68 5 91
5 13 759.80 20 14.76 1509 445 4.05 / 849.12 5 97
6 13 310.00 20 14.89 849 253 4.30 / 849.38 5 97
7 13 309.88 20 14.92 644 192 4.49 / 849.57 5 96
8 13 20.96 20 14.97 359 107 4.60 / 849.67 5 89
9 8 -0.08 218 14.91 324 1053 5.65 / 850.73 5 129
Average= 26.59
(KJ/cycle)

Cycle 152 GMT 29/ 4/2023 4:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 32 14.95 486 233 0.23 / 840.01 5 27
2 7 2004.80 40 14.44 3254 1880 2.11 / 841.89 27 69
3 13 1718.04 20 14.51 2869 833 2.94 / 842.72 5 81
4 13 1241.84 20 14.61 2202 643 3.59 / 843.37 5 92
5 13 548.44 20 14.86 1190 354 3.94 / 843.72 5 97
6 13 38.12 20 15.07 387 117 4.06 / 843.84 5 77
7 8 0.12 261 15.01 316 1238 5.30 / 845.07 5 132
Average= 27.26
(KJ/cycle)

Cycle 151 GMT 19/ 4/2023 7:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 32 14.94 505 241 0.24 / 834.64 5 32
2 7 2003.92 40 14.45 3251 1879 2.12 / 836.52 32 69
3 13 1809.00 20 14.48 2993 867 2.99 / 837.38 5 81
4 13 1331.00 20 14.58 2321 677 3.66 / 838.06 5 90
5 13 626.00 20 14.83 1297 385 4.05 / 838.45 5 97
6 8 1.20 280 15.01 317 1332 5.38 / 839.78 5 130
Average= 27.99
(KJ/cycle)

Cycle 150 GMT 9/ 4/2023 9:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 32 14.95 500 239 0.24 / 829.24 5 29
2 3 1026.60 1 14.98 1911 29 0.27 / 829.27 5 29
3 7 2004.04 40 14.45 3249 1878 2.15 / 831.15 29 70
4 13 1628.92 20 14.54 2738 796 2.94 / 831.94 5 84
5 13 1179.36 20 14.64 2117 620 3.56 / 832.56 5 92
6 13 666.40 20 14.81 1354 401 3.96 / 832.96 5 98
7 13 139.20 20 15.03 538 162 4.12 / 833.13 5 93
8 13 23.48 20 15.05 359 108 4.23 / 833.23 5 84
9 8 0.08 242 14.99 321 1164 5.40 / 834.40 5 130
Average= 28.77
(KJ/cycle)

Cycle 149 GMT 30/ 3/2023 12:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 30 14.95 502 225 0.23 / 823.89 5 30
2 3 1059.32 1 14.91 1957 29 0.25 / 823.92 5 53
3 7 2006.36 40 14.45 3245 1876 2.13 / 825.80 53 69
4 13 1732.40 20 14.51 2872 833 2.96 / 826.63 5 81
5 13 1167.20 20 14.64 2084 610 3.57 / 827.24 5 94
6 13 595.04 20 14.85 1248 371 3.94 / 827.61 5 99
7 13 101.60 20 15.04 475 143 4.09 / 827.75 5 90
8 8 0.12 264 15.01 315 1248 5.34 / 829.00 5 134
Average= 29.61
(KJ/cycle)

Cycle 148 GMT 20/ 3/2023 14:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 32 14.96 475 227 0.23 / 818.61 5 30
2 3 935.24 -1 15.30 0 0 0.00 / 818.61 5 30
3 7 2007.12 40 14.45 3250 1878 2.11 / 820.49 30 70
4 13 1817.72 20 14.48 3008 871 2.98 / 821.36 5 80
5 13 1152.36 20 14.65 2069 606 3.58 / 821.97 5 94
6 13 572.96 20 14.85 1219 362 3.95 / 822.33 5 98
7 8 0.12 280 15.02 318 1337 5.28 / 823.67 5 132
Average= 30.51
(KJ/cycle)

Cycle 147 GMT 10/ 3/2023 17: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 32 14.94 501 240 0.24 / 813.26 5 31
2 7 2015.08 40 14.45 3265 1887 2.13 / 815.14 31 71
3 13 1832.24 20 14.48 3024 876 3.00 / 816.02 5 78
4 13 1343.24 20 14.58 2352 686 3.69 / 816.70 5 88
5 13 556.92 20 14.86 1202 357 4.05 / 817.06 5 98
6 8 0.12 280 15.02 314 1321 5.37 / 818.38 5 137
Average= 31.48
(KJ/cycle)

Cycle 146 GMT 28/ 2/2023 19:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 32 14.95 497 238 0.24 / 807.88 5 30
2 7 2003.44 40 14.46 3240 1874 2.11 / 809.76 30 70
3 13 1812.96 20 14.50 2992 868 2.98 / 810.62 5 79
4 13 1067.44 20 14.69 1948 572 3.55 / 811.20 5 94
5 13 592.08 20 14.85 1256 373 3.92 / 811.57 5 98
6 13 182.60 20 15.01 616 185 4.11 / 811.75 5 92
7 8 0.36 259 15.00 325 1263 5.37 / 813.02 5 139
Average= 32.52
(KJ/cycle)

Cycle 145 GMT 18/ 2/2023 21:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 32 14.96 493 236 0.24 / 802.42 5 30
2 7 2006.08 40 14.44 3269 1888 2.12 / 804.31 30 70
3 13 1818.20 20 14.48 2998 868 2.99 / 805.18 5 79
4 13 1320.12 20 14.59 2318 676 3.67 / 805.85 5 91
5 13 621.08 20 14.84 1298 385 4.05 / 806.24 5 98
6 13 115.40 20 15.04 516 155 4.21 / 806.39 5 87
7 8 0.04 257 15.01 324 1250 5.46 / 807.64 5 132
Average= 33.65
(KJ/cycle)

Cycle 144 GMT 9/ 2/2023 0:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 32 14.95 512 245 0.24 / 797.11 5 31
2 7 2004.24 40 14.47 3236 1873 2.12 / 798.99 7 67
3 13 1721.84 20 14.52 2863 831 2.95 / 799.82 5 82
4 13 1163.84 20 14.65 2083 610 3.56 / 800.43 5 94
5 13 674.76 20 14.82 1368 405 3.97 / 800.83 5 99
6 13 12.88 20 15.09 335 101 4.07 / 800.93 5 73
7 8 0.04 261 15.02 319 1251 5.32 / 802.18 5 135
Average= 34.88
(KJ/cycle)

Cycle 143 GMT 30/ 1/2023 2:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 31 14.96 507 235 0.24 / 791.68 5 31
2 7 2006.12 40 14.46 3255 1883 2.12 / 793.57 8 68
3 13 1732.16 20 14.51 2892 839 2.96 / 794.41 5 81
4 13 1244.68 20 14.62 2197 642 3.60 / 795.05 5 91
5 13 568.24 20 14.86 1233 366 3.97 / 795.41 5 98
6 13 177.40 20 15.02 622 187 4.15 / 795.60 5 91
7 8 -0.04 263 15.01 321 1267 5.42 / 796.87 5 133
Average= 36.22
(KJ/cycle)

Cycle 142 GMT 20/ 1/2023 5:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 31 14.95 498 231 0.23 / 786.20 5 32
2 7 2011.56 40 14.46 3267 1890 2.12 / 788.09 32 70
3 13 1811.96 20 14.50 2989 867 2.99 / 788.96 5 80
4 13 1321.16 20 14.60 2304 673 3.66 / 789.63 5 89
5 13 615.60 20 14.84 1291 383 4.04 / 790.02 5 99
6 8 0.24 287 15.02 332 1431 5.47 / 791.45 5 130
Average= 37.69
(KJ/cycle)

Cycle 141 GMT 10/ 1/2023 8: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 31 14.95 500 232 0.23 / 780.80 5 34
2 7 2012.04 40 14.45 3262 1885 2.12 / 782.69 34 71
3 13 1820.76 20 14.48 3025 876 2.99 / 783.56 5 79
4 13 1153.08 20 14.66 2069 607 3.60 / 784.17 5 94
5 13 663.20 20 14.82 1352 401 4.00 / 784.57 5 99
6 13 147.88 20 15.03 552 166 4.17 / 784.74 5 90
7 8 0.00 259 15.01 318 1236 5.40 / 785.97 5 130
Average= 39.30
(KJ/cycle)

Cycle 140 GMT 31/12/2022 10:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 31 14.95 499 231 0.23 / 775.51 5 36
2 3 1023.80 1 14.99 1890 28 0.26 / 775.54 5 20
3 7 2007.32 40 14.45 3250 1878 2.14 / 777.42 20 69
4 13 1711.88 20 14.53 2857 830 2.97 / 778.25 5 80
5 13 1141.12 20 14.66 2042 599 3.57 / 778.85 5 92
6 13 558.16 20 14.87 1202 357 3.92 / 779.20 5 99
7 13 17.56 20 15.08 349 105 4.03 / 779.31 5 78
8 8 0.04 264 15.02 318 1261 5.29 / 780.57 5 136
Average= 41.08
(KJ/cycle)

Cycle 139 GMT 21/12/2022 12:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 31 14.95 498 231 0.23 / 770.26 5 36
2 7 2002.96 40 14.46 3255 1883 2.11 / 772.15 36 70
3 13 1717.00 20 14.53 2867 833 2.95 / 772.98 5 82
4 13 1149.88 20 14.66 2060 604 3.55 / 773.58 5 94
5 13 575.92 20 14.86 1231 366 3.92 / 773.95 5 98
6 8 7.88 276 15.02 321 1331 5.25 / 775.28 5 129
Average= 43.07
(KJ/cycle)

Cycle 138 GMT 11/12/2022 15:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 31 14.96 483 224 0.22 / 764.87 5 37
2 7 2010.40 40 14.45 3274 1892 2.12 / 766.76 37 67
3 13 1734.28 20 14.51 2899 841 2.96 / 767.60 5 79
4 13 1182.00 20 14.65 2116 620 3.58 / 768.22 5 92
5 13 621.64 20 14.84 1310 389 3.97 / 768.61 5 99
6 13 16.36 20 15.08 346 104 4.07 / 768.72 5 75
7 8 0.16 264 15.01 332 1316 5.39 / 770.03 5 136
Average= 45.30
(KJ/cycle)

Cycle 137 GMT 1/12/2022 17:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 31 14.96 487 226 0.23 / 759.43 5 37
2 7 2005.68 41 14.45 3241 1920 2.15 / 761.35 37 70
3 13 1726.12 20 14.52 2889 839 2.98 / 762.19 5 81
4 13 1342.72 20 14.59 2332 680 3.67 / 762.87 5 91
5 13 721.24 20 14.80 1438 426 4.09 / 763.30 5 99
6 8 0.20 282 15.02 319 1351 5.44 / 764.65 5 132
Average= 47.79
(KJ/cycle)

Cycle 136 GMT 21/11/2022 20:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 31 14.96 491 228 0.23 / 754.14 5 39
2 7 2010.88 40 14.46 3261 1886 2.11 / 756.03 39 69
3 13 1725.68 20 14.52 2878 836 2.95 / 756.86 5 83
4 13 1079.80 20 14.69 1965 577 3.53 / 757.44 5 92
5 13 584.76 20 14.86 1238 368 3.89 / 757.81 5 98
6 13 95.68 20 15.06 467 141 4.04 / 757.95 5 86
7 8 0.04 261 15.01 321 1258 5.29 / 759.20 5 130
Average= 50.61
(KJ/cycle)

Cycle 135 GMT 11/11/2022 22:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 31 14.95 507 235 0.23 / 748.67 5 35
2 7 2003.88 40 14.46 3263 1887 2.12 / 750.55 35 68
3 13 1810.24 20 14.50 2998 869 2.99 / 751.42 5 79
4 13 1326.80 20 14.60 2321 678 3.67 / 752.10 5 91
5 13 556.08 20 14.88 1197 356 4.03 / 752.46 5 99
6 13 16.20 20 15.09 335 101 4.13 / 752.56 5 72
7 8 0.04 266 15.02 339 1354 5.48 / 753.91 5 140
Average= 53.85
(KJ/cycle)

Cycle 134 GMT 2/11/2022 1:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 29 14.96 509 221 0.22 / 742.97 5 38
2 10 1000.88 3 14.87 1890 84 0.31 / 743.05 5 64
3 3 956.20 -1 15.30 0 0 0.08 / 743.05 5 64
4 7 2006.76 40 14.46 3272 1893 2.20 / 744.94 64 68
5 13 1909.40 20 14.47 3156 913 3.11 / 745.86 5 76
6 13 1144.56 20 14.66 2089 612 3.72 / 746.47 5 93
7 13 669.80 20 14.82 1388 411 4.13 / 746.88 5 96
8 13 173.68 20 15.03 623 187 4.32 / 747.07 5 90
9 13 7.88 20 15.08 342 103 4.43 / 747.17 5 77
10 8 0.12 246 15.01 341 1259 5.68 / 748.43 5 136
Average= 57.57
(KJ/cycle)

Cycle 133 GMT 23/10/2022 3:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 31 14.95 502 233 0.23 / 737.56 5 36
2 3 942.92 -1 15.31 0 0 0.00 / 737.56 5 36
3 7 2004.36 40 14.46 3256 1883 2.12 / 739.44 36 70
4 13 1801.48 20 14.50 2974 862 2.98 / 740.30 5 81
5 13 1206.04 20 14.64 2158 632 3.61 / 740.94 5 93
6 13 539.84 20 14.88 1193 355 3.97 / 741.29 5 98
7 8 0.08 285 15.02 340 1455 5.42 / 742.75 5 142
Average= 61.90
(KJ/cycle)

Cycle 132 GMT 13/10/2022 6:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 30 14.96 516 232 0.23 / 732.08 5 37
2 3 1029.16 1 14.99 1914 29 0.26 / 732.11 5 33
3 7 2010.44 40 14.46 3266 1889 2.15 / 733.99 33 71
4 13 1726.40 20 14.53 2868 833 2.98 / 734.83 5 82
5 13 1240.40 20 14.63 2193 642 3.62 / 735.47 5 93
6 13 639.76 20 14.84 1318 391 4.02 / 735.86 5 100
7 13 85.88 20 15.07 459 138 4.15 / 736.00 5 83
8 8 0.20 265 15.02 333 1325 5.48 / 737.33 5 135
Average= 67.03
(KJ/cycle)

Cycle 131 GMT 3/10/2022 8:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 30 14.89 505 226 0.23 / 726.61 5 39
2 7 2014.76 40 14.48 3259 1888 2.11 / 728.49 39 69
3 13 1817.76 20 14.51 3000 871 2.98 / 729.37 5 80
4 13 1329.32 20 14.61 2315 676 3.66 / 730.04 5 90
5 13 616.00 20 14.86 1285 382 4.04 / 730.42 5 100
6 13 12.04 20 15.09 348 105 4.15 / 730.53 5 78
7 8 0.12 261 15.02 336 1317 5.46 / 731.85 5 137
Average= 73.18
(KJ/cycle)

Cycle 130 GMT 23/ 9/2022 11: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 30 14.97 478 215 0.21 / 721.04 5 37
2 7 2009.44 40 14.46 3247 1878 2.09 / 722.92 37 69
3 13 1724.76 20 14.53 2871 834 2.93 / 723.75 5 80
4 13 1150.40 20 14.67 2063 605 3.53 / 724.36 5 95
5 13 839.04 20 14.75 1614 476 4.01 / 724.83 5 98
6 13 341.52 20 14.92 781 233 4.24 / 725.07 5 100
7 13 341.52 20 14.95 571 171 4.41 / 725.24 5 98
8 8 -0.04 235 14.93 326 1144 5.56 / 726.38 5 132
Average= 80.71
(KJ/cycle)

Cycle 129 GMT 13/ 9/2022 13:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 31 14.96 505 234 0.23 / 715.79 5 38
2 7 2014.96 40 14.46 3269 1891 2.12 / 717.68 38 70
3 13 1659.92 20 14.55 2779 809 2.93 / 718.49 5 84
4 13 1186.36 20 14.66 2101 616 3.55 / 719.10 5 93
5 13 512.28 20 14.90 1132 337 3.89 / 719.44 5 99
6 13 124.64 20 15.06 520 157 4.04 / 719.60 5 89
7 8 0.12 261 15.03 313 1228 5.27 / 720.83 5 130
Average= 90.10
(KJ/cycle)

Cycle 128 GMT 3/ 9/2022 16: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.12 31 14.97 505 234 0.23 / 710.38 5 35
2 7 2003.48 40 14.47 3240 1875 2.11 / 712.26 35 70
3 13 1812.84 20 14.50 2997 869 2.98 / 713.12 5 80
4 13 1326.24 20 14.61 2299 672 3.65 / 713.80 5 91
5 13 692.36 20 14.82 1389 412 4.06 / 714.21 5 98
6 8 0.08 278 15.03 322 1345 5.41 / 715.55 5 133
Average= 102.22
(KJ/cycle)

Cycle 127 GMT 24/ 8/2022 18:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 31 14.98 491 228 0.23 / 705.04 5 37
2 7 2014.08 40 14.46 3270 1891 2.12 / 706.93 37 70
3 13 1744.52 20 14.52 2911 845 2.96 / 707.78 5 82
4 13 1182.40 20 14.66 2112 619 3.58 / 708.40 5 92
5 13 608.24 20 14.86 1276 379 3.96 / 708.78 5 98
6 13 22.28 20 15.09 346 104 4.07 / 708.88 5 82
7 8 0.12 264 15.03 319 1266 5.33 / 710.15 5 130
Average= 118.36
(KJ/cycle)

Cycle 126 GMT 14/ 8/2022 20:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 31 14.97 518 240 0.24 / 699.55 5 35
2 7 2010.84 40 14.47 3256 1885 2.12 / 701.44 35 70
3 13 1920.16 20 14.48 3134 908 3.03 / 702.34 5 77
4 13 1382.44 20 14.58 2396 699 3.73 / 703.04 5 90
5 13 677.24 20 14.83 1372 407 4.14 / 703.45 5 99
6 13 97.80 20 15.07 473 143 4.28 / 703.59 5 87
7 13 13.04 20 15.09 331 100 4.38 / 703.69 5 78
8 8 0.04 231 15.03 323 1121 5.50 / 704.81 5 130
Average= 140.96
(KJ/cycle)

Cycle 125 GMT 4/ 8/2022 23:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 32 14.91 518 247 0.25 / 694.21 5 39
2 3 957.12 -1 15.32 0 0 0.00 / 694.21 5 39
3 7 2005.96 40 14.47 3252 1882 2.13 / 696.09 39 71
4 13 1728.16 20 14.53 2882 838 2.97 / 696.93 5 83
5 13 1232.12 20 14.64 2195 643 3.61 / 697.57 5 93
6 13 452.52 20 14.93 1062 317 3.93 / 697.89 5 99
7 13 29.52 20 15.10 372 112 4.04 / 698.00 5 78
8 8 0.08 255 15.03 341 1307 5.35 / 699.31 5 135
Average= 174.83
(KJ/cycle)

Cycle 124 GMT 26/ 7/2022 2: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 30 14.93 505 226 0.23 / 688.50 5 32
2 3 1087.12 2 14.89 2013 60 0.29 / 688.56 5 66
3 7 2005.60 40 14.47 3262 1888 2.17 / 690.45 66 69
4 13 1815.44 20 14.51 2981 865 3.04 / 691.32 5 80
5 13 1259.16 20 14.64 2214 648 3.69 / 691.97 5 92
6 13 577.96 20 14.88 1232 367 4.05 / 692.33 5 98
7 13 323.24 20 14.98 750 225 4.28 / 692.56 5 98
8 13 323.24 20 15.00 578 173 4.45 / 692.73 5 93
9 8 -0.08 244 14.97 338 1235 5.69 / 693.96 5 130
Average= 231.32
(KJ/cycle)

Cycle 123 GMT 16/ 7/2022 4:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 32 14.98 495 237 0.24 / 683.01 5 32
2 3 941.96 -1 15.32 0 0 0.00 / 683.01 5 32
3 7 2005.44 40 14.47 3252 1882 2.12 / 684.89 32 70
4 13 1814.20 20 14.50 2983 865 2.98 / 685.75 5 78
5 13 1226.92 20 14.64 2166 634 3.62 / 686.39 5 93
6 13 559.36 20 14.88 1206 359 3.98 / 686.75 5 98
7 13 302.76 20 14.98 738 221 4.20 / 686.97 5 95
8 13 302.76 20 15.00 543 163 4.36 / 687.13 5 94
9 8 0.12 240 14.98 319 1147 5.51 / 688.28 5 132
Average= 344.14
(KJ/cycle)

Cycle 122 GMT 6/ 7/2022 7:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 31 14.97 500 232 0.23 / 677.65 5 31
2 3 1022.12 1 15.01 1921 29 0.26 / 677.68 5 16
3 7 2003.44 41 14.47 3256 1932 2.19 / 679.61 16 71
4 13 1720.16 20 14.53 2865 833 3.03 / 680.45 5 82
5 13 1139.72 20 14.68 2057 604 3.63 / 681.05 5 94
6 13 471.40 20 14.93 1077 322 3.95 / 681.37 5 98
7 8 3.00 285 15.04 326 1397 5.35 / 682.77 5 134
Average= 682.77
(KJ/cycle)

Cycle 120 GMT 16/ 6/2022 12: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 32 14.93 498 238 0.24 / 672.21 5 35
2 7 2009.40 40 14.47 3266 1890 2.13 / 674.10 35 70
3 13 1719.32 20 14.54 2869 834 2.96 / 674.94 5 80
4 13 1243.60 20 14.64 2196 643 3.61 / 675.58 5 91
5 13 542.88 20 14.87 1201 357 3.96 / 675.94 5 98
6 13 240.56 20 14.95 671 201 4.16 / 676.14 5 96
7 13 240.56 20 14.98 466 140 4.30 / 676.28 5 90
8 8 0.04 235 14.95 325 1142 5.44 / 677.42 5 135
Average= 5.60
(KJ/cycle)

Cycle 119 GMT 6/ 6/2022 14:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 32 14.99 470 225 0.23 / 666.66 5 33
2 7 2014.96 40 14.47 3261 1887 2.11 / 668.55 33 69
3 13 1832.56 20 14.50 3020 876 2.99 / 669.42 5 78
4 13 1330.16 20 14.61 2309 675 3.66 / 670.10 5 92
5 13 631.28 20 14.86 1305 388 4.05 / 670.49 5 99
6 13 228.48 20 14.99 692 207 4.26 / 670.69 5 97
7 13 228.48 20 15.01 509 153 4.41 / 670.85 5 92
8 8 0.16 238 14.99 317 1131 5.54 / 671.98 5 132
Average= 5.60
(KJ/cycle)

Cycle 118 GMT 27/ 5/2022 17:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.88 32 14.94 496 237 0.24 / 661.37 5 34
2 7 2010.32 40 14.47 3260 1887 2.12 / 663.26 34 71
3 13 1818.64 20 14.51 2995 869 2.99 / 664.13 5 81
4 13 1065.84 20 14.72 1934 569 3.56 / 664.70 5 93
5 13 688.48 20 14.84 1375 408 3.97 / 665.11 5 99
6 8 0.16 285 15.05 309 1325 5.30 / 666.43 5 139
Average= 5.60
(KJ/cycle)

Cycle 117 GMT 17/ 5/2022 19:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 32 14.98 504 242 0.24 / 655.89 5 32
2 7 2003.76 40 14.49 3236 1876 2.12 / 657.76 32 68
3 13 1805.52 20 14.52 2975 864 2.98 / 658.62 5 78
4 13 1303.40 20 14.62 2283 668 3.65 / 659.29 5 89
5 13 537.12 20 14.90 1169 348 4.00 / 659.64 5 97
6 13 258.52 20 15.00 705 211 4.21 / 659.85 5 91
7 13 258.52 20 15.02 508 153 4.36 / 660.00 5 90
8 8 0.12 240 14.99 315 1133 5.49 / 661.14 5 132
Average= 5.60
(KJ/cycle)

Cycle 116 GMT 7/ 5/2022 22:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 32 14.99 504 242 0.24 / 650.54 5 33
2 7 2008.40 40 14.47 3266 1890 2.13 / 652.43 33 69
3 13 1914.32 20 14.49 3102 899 3.03 / 653.33 5 78
4 13 1052.00 20 14.72 1921 566 3.60 / 653.89 5 95
5 13 497.68 20 14.93 1105 330 3.93 / 654.22 5 98
6 8 0.16 282 15.05 335 1422 5.35 / 655.64 5 137
Average= 5.60
(KJ/cycle)

Cycle 115 GMT 28/ 4/2022 0:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 32 14.95 497 238 0.24 / 645.26 5 33
2 7 2010.56 40 14.48 3257 1886 2.12 / 647.14 33 68
3 13 1813.76 20 14.51 3010 874 3.00 / 648.02 5 78
4 13 1090.04 20 14.71 1993 586 3.58 / 648.60 5 94
5 13 541.96 20 14.91 1187 354 3.94 / 648.96 5 96
6 8 0.12 278 15.05 320 1339 5.28 / 650.30 5 129
Average= 5.61
(KJ/cycle)

Cycle 114 GMT 18/ 4/2022 2:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 32 14.92 502 240 0.24 / 639.83 5 27
2 7 2006.20 40 14.49 3262 1891 2.13 / 641.72 27 71
3 13 1728.64 20 14.54 2895 842 2.97 / 642.57 5 82
4 13 1228.00 20 14.66 2173 637 3.61 / 643.20 5 92
5 13 541.40 20 14.90 1185 353 3.96 / 643.56 5 99
6 13 129.12 20 15.04 543 163 4.13 / 643.72 5 90
7 13 88.80 20 15.06 410 123 4.25 / 643.84 5 87
8 8 0.04 244 15.00 321 1175 5.42 / 645.02 5 135
Average= 5.61
(KJ/cycle)

Cycle 113 GMT 8/ 4/2022 4:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 33 14.93 493 243 0.24 / 634.10 5 32
2 7 2004.76 41 14.48 3251 1930 2.17 / 636.03 32 69
3 13 1817.48 20 14.53 2981 866 3.04 / 636.90 5 81
4 13 1248.80 20 14.65 2201 645 3.68 / 637.54 5 91
5 13 557.64 20 14.89 1214 362 4.05 / 637.90 5 100
6 13 360.08 20 14.93 893 267 4.31 / 638.17 5 99
7 13 307.52 20 14.94 702 210 4.52 / 638.38 5 98
8 13 307.52 20 14.99 441 132 4.65 / 638.51 5 97
9 8 0.08 225 14.96 322 1084 5.74 / 639.59 5 140
Average= 5.61
(KJ/cycle)

Cycle 112 GMT 29/ 3/2022 7:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.28 31 14.92 516 239 0.24 / 628.52 5 26
2 10 1017.36 3 14.89 1894 85 0.32 / 628.60 5 65
3 7 2010.12 40 14.48 3275 1897 2.22 / 630.50 65 69
4 13 1821.76 20 14.51 3024 878 3.10 / 631.38 5 81
5 13 1130.08 20 14.69 2049 602 3.70 / 631.98 5 95
6 13 544.92 20 14.90 1211 361 4.06 / 632.34 5 97
7 13 255.72 20 14.96 768 230 4.29 / 632.57 5 96
8 8 0.04 253 14.97 340 1288 5.58 / 633.86 5 131
Average= 5.61
(KJ/cycle)

Cycle 111 GMT 19/ 3/2022 10: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 30 14.93 499 224 0.22 / 623.13 5 29
2 7 2006.64 40 14.48 3261 1889 2.11 / 625.02 29 68
3 13 1821.60 20 14.52 2998 871 2.98 / 625.89 5 80
4 13 1081.72 20 14.72 1974 581 3.56 / 626.47 5 93
5 13 513.28 20 14.90 1157 345 3.91 / 626.82 5 97
6 13 204.76 20 14.97 669 200 4.11 / 627.02 5 96
7 8 0.04 261 14.97 323 1262 5.37 / 628.28 5 130
Average= 5.61
(KJ/cycle)

Cycle 110 GMT 9/ 3/2022 12:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 32 14.93 500 239 0.24 / 617.58 5 33
2 3 958.00 -1 15.33 0 0 0.00 / 617.58 5 33
3 7 2018.88 40 14.47 3279 1898 2.14 / 619.48 33 71
4 13 1927.40 20 14.48 3156 914 3.05 / 620.39 5 77
5 13 1202.92 20 14.66 2145 629 3.68 / 621.02 5 94
6 13 713.08 20 14.83 1433 425 4.10 / 621.45 5 99
7 13 192.32 20 14.98 659 197 4.30 / 621.64 5 95
8 8 0.00 257 14.98 328 1263 5.56 / 622.91 5 129
Average= 5.61
(KJ/cycle)

Cycle 109 GMT 27/ 2/2022 15: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 32 14.96 505 242 0.24 / 612.03 5 31
2 7 2002.72 40 14.48 3267 1892 2.13 / 613.92 31 70
3 13 1803.64 20 14.52 2986 867 3.00 / 614.79 5 80
4 13 1332.68 20 14.62 2331 682 3.68 / 615.47 5 91
5 13 641.56 20 14.86 1331 396 4.08 / 615.87 5 99
6 13 219.72 20 14.99 700 210 4.29 / 616.08 5 96
7 8 0.00 261 14.99 323 1264 5.55 / 617.34 5 130
Average= 5.61
(KJ/cycle)

Cycle 108 GMT 17/ 2/2022 17:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 31 14.92 507 234 0.23 / 606.62 5 29
2 3 1025.52 1 15.02 1906 29 0.26 / 606.65 5 21
3 7 2017.12 40 14.49 3267 1894 2.16 / 608.54 21 69
4 13 1736.36 20 14.55 2872 836 2.99 / 609.38 5 82
5 13 1179.24 20 14.69 2110 620 3.61 / 610.00 5 94
6 13 603.28 20 14.89 1268 378 3.99 / 610.37 5 98
7 13 105.20 20 15.07 499 150 4.14 / 610.52 5 88
8 8 0.08 261 15.02 323 1266 5.41 / 611.79 5 130
Average= 5.61
(KJ/cycle)

Cycle 107 GMT 7/ 2/2022 19:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 31 14.96 503 233 0.23 / 600.93 5 33
2 3 1020.24 1 15.04 1907 29 0.26 / 600.96 5 17
3 7 2010.80 40 14.49 3271 1896 2.16 / 602.85 17 68
4 13 1815.24 20 14.52 3013 875 3.03 / 603.73 5 79
5 13 1321.32 20 14.63 2314 677 3.71 / 604.40 5 88
6 13 731.40 20 14.82 1461 433 4.14 / 604.84 5 99
7 13 285.32 20 14.95 805 241 4.38 / 605.08 5 96
8 8 0.12 266 14.97 328 1306 5.69 / 606.38 5 135
Average= 5.61
(KJ/cycle)

Cycle 106 GMT 28/ 1/2022 22:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 30 14.97 501 225 0.22 / 595.41 5 34
2 3 1048.48 1 14.97 1944 29 0.25 / 595.44 5 54
3 7 2004.24 40 14.49 3255 1887 2.14 / 597.32 54 70
4 13 1725.52 20 14.55 2873 836 2.98 / 598.16 5 81
5 13 1253.84 20 14.65 2213 648 3.63 / 598.81 5 92
6 13 753.20 20 14.81 1490 441 4.07 / 599.25 5 97
7 13 117.84 20 15.05 533 160 4.23 / 599.41 5 89
8 8 0.12 263 15.02 325 1284 5.51 / 600.69 5 134
Average= 5.61
(KJ/cycle)

Cycle 105 GMT 19/ 1/2022 1: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 31 14.92 495 229 0.23 / 589.89 5 34
2 3 937.84 -1 15.33 0 0 0.00 / 589.89 5 34
3 7 2009.12 40 14.49 3279 1901 2.13 / 591.79 34 70
4 13 1817.48 20 14.52 3022 878 3.01 / 592.67 5 79
5 13 1332.44 20 14.63 2341 685 3.69 / 593.36 5 89
6 13 535.76 20 14.91 1201 358 4.05 / 593.71 5 99
7 13 77.08 20 15.08 475 143 4.19 / 593.86 5 84
8 8 0.16 257 15.03 343 1325 5.52 / 595.18 5 134
Average= 5.61
(KJ/cycle)

Cycle 104 GMT 9/ 1/2022 3:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 31 14.94 490 227 0.23 / 584.29 5 33
2 7 2013.84 40 14.48 3251 1883 2.11 / 586.17 33 67
3 13 1731.84 20 14.55 2884 839 2.95 / 587.01 5 80
4 13 1260.00 20 14.66 2214 649 3.60 / 587.66 5 92
5 13 953.60 20 14.74 1768 521 4.12 / 588.18 5 97
6 13 171.88 20 15.00 612 184 4.30 / 588.36 5 93
7 8 0.12 268 14.98 324 1301 5.60 / 589.66 5 133
Average= 5.62
(KJ/cycle)

Cycle 103 GMT 30/12/2021 6:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 31 14.82 511 235 0.23 / 578.89 5 33
2 3 1022.88 1 15.02 1913 29 0.26 / 578.92 5 19
3 7 2007.76 40 14.52 3250 1888 2.15 / 580.81 19 70
4 13 1718.08 20 14.58 2858 833 2.98 / 581.64 5 82
5 13 1051.12 20 14.75 1916 565 3.55 / 582.21 5 94
6 13 663.00 20 14.87 1346 400 3.95 / 582.61 5 99
7 13 294.28 20 15.02 659 198 4.15 / 582.80 5 95
8 8 0.12 261 15.00 321 1257 5.40 / 584.06 5 132
Average= 5.62
(KJ/cycle)

Cycle 102 GMT 20/12/2021 8:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 30 14.99 512 230 0.23 / 572.25 5 37
2 7 2010.60 40 14.48 3268 1893 2.12 / 574.14 5 70
3 13 1924.92 20 14.46 3166 916 3.04 / 575.06 5 77
4 13 1582.84 20 14.47 2699 781 3.82 / 575.84 5 84
5 13 1030.16 20 14.57 1922 560 4.38 / 576.40 5 95
6 13 750.24 20 14.67 1406 413 4.79 / 576.81 5 98
7 13 750.24 20 14.70 1193 351 5.14 / 577.16 5 100
8 13 750.24 20 14.74 945 279 5.42 / 577.44 5 103
9 13 750.24 20 14.79 677 200 5.62 / 577.64 5 104
10 8 -0.08 206 14.81 332 1013 6.63 / 578.66 5 143
Average= 5.62
(KJ/cycle)

Cycle 101 GMT 10/12/2021 12:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 30 14.99 498 224 0.22 / 566.93 5 40
2 7 2004.52 40 14.48 3266 1892 2.12 / 568.82 40 70
3 13 1709.04 20 14.56 2848 829 2.94 / 569.65 5 79
4 13 1239.60 20 14.66 2188 642 3.59 / 570.29 5 93
5 13 565.08 20 14.91 1216 363 3.95 / 570.65 5 98
6 8 0.20 280 15.06 325 1370 5.32 / 572.02 5 131
Average= 5.61
(KJ/cycle)

Cycle 100 GMT 30/11/2021 15: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 30 14.98 510 229 0.23 / 561.51 5 36
2 7 2012.96 40 14.48 3276 1897 2.13 / 563.41 36 70
3 13 1721.44 20 14.55 2888 840 2.97 / 564.25 5 80
4 13 1249.80 20 14.66 2219 651 3.62 / 564.90 5 93
5 13 549.52 20 14.91 1192 355 3.97 / 565.26 5 99
6 8 0.20 282 15.06 340 1444 5.42 / 566.70 5 134
Average= 5.61
(KJ/cycle)

Cycle 99 GMT 20/11/2021 17:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 30 14.98 515 231 0.23 / 556.06 5 39
2 7 2009.96 40 14.48 3282 1901 2.13 / 557.96 7 68
3 13 1914.08 20 14.49 3135 909 3.04 / 558.87 5 78
4 13 1132.56 20 14.71 2057 605 3.65 / 559.48 5 94
5 13 655.36 20 14.87 1361 405 4.05 / 559.88 5 98
6 8 0.24 278 15.06 335 1403 5.45 / 561.28 5 129
Average= 5.61
(KJ/cycle)

Cycle 98 GMT 10/11/2021 19:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 30 14.99 507 228 0.23 / 550.74 5 40
2 7 2003.04 40 14.49 3246 1881 2.11 / 552.62 40 70
3 13 1716.76 20 14.56 2841 827 2.94 / 553.44 5 82
4 13 1127.04 20 14.71 2021 595 3.53 / 554.04 5 93
5 13 623.72 20 14.88 1306 389 3.92 / 554.43 5 97
6 8 0.08 280 15.06 333 1404 5.32 / 555.83 5 131
Average= 5.61
(KJ/cycle)

Cycle 97 GMT 31/10/2021 22:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 30 15.00 512 230 0.23 / 545.45 5 39
2 7 2013.96 40 14.49 3267 1894 2.12 / 547.34 5 70
3 13 1736.68 20 14.55 2890 841 2.96 / 548.18 5 81
4 13 1187.88 20 14.69 2121 623 3.59 / 548.80 5 92
5 13 505.96 20 14.94 1122 335 3.92 / 549.14 5 97
6 8 0.12 280 15.07 324 1367 5.29 / 550.51 5 129
Average= 5.62
(KJ/cycle)

Cycle 96 GMT 22/10/2021 0:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.92 30 15.00 497 224 0.22 / 540.11 5 36
2 7 2011.52 41 14.48 3269 1941 2.16 / 542.05 36 71
3 13 1815.84 20 14.52 3005 873 3.04 / 542.93 5 79
4 13 1158.36 20 14.69 2078 611 3.65 / 543.54 5 93
5 13 490.36 20 14.95 1106 331 3.98 / 543.87 5 98
6 8 0.12 278 15.07 322 1349 5.33 / 545.22 5 130
Average= 5.62
(KJ/cycle)

Cycle 95 GMT 12/10/2021 3: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 30 14.98 497 223 0.22 / 534.64 5 35
2 7 2005.00 40 14.49 3258 1888 2.11 / 536.53 35 70
3 13 1818.44 20 14.53 3001 872 2.98 / 537.40 5 78
4 13 1505.36 20 14.57 2584 753 3.74 / 538.15 5 87
5 13 585.52 20 14.90 1247 372 4.11 / 538.52 5 100
6 8 0.16 278 15.07 326 1366 5.47 / 539.89 5 134
Average= 5.62
(KJ/cycle)

Cycle 94 GMT 2/10/2021 5:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 31 14.99 526 244 0.24 / 529.22 5 38
2 3 959.56 -1 15.34 0 0 0.00 / 529.22 5 38
3 7 2007.76 40 14.48 3250 1882 2.13 / 531.10 38 72
4 13 1811.92 20 14.53 2985 867 2.99 / 531.97 5 80
5 13 1226.96 20 14.67 2189 642 3.64 / 532.61 5 94
6 13 640.68 20 14.88 1323 394 4.03 / 533.00 5 100
7 13 121.88 20 15.09 536 162 4.19 / 533.17 5 90
8 8 0.28 257 15.06 323 1250 5.44 / 534.42 5 132
Average= 5.63
(KJ/cycle)

Cycle 93 GMT 22/ 9/2021 8:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.96 31 14.99 516 240 0.24 / 523.75 5 37
2 7 2010.56 40 14.49 3269 1895 2.13 / 525.65 37 72
3 13 1823.56 20 14.52 3024 878 3.01 / 526.53 5 81
4 13 1067.20 20 14.74 1960 578 3.59 / 527.10 5 95
5 13 679.16 20 14.86 1399 416 4.01 / 527.52 5 96
6 8 1.00 282 15.06 342 1452 5.46 / 528.97 5 133
Average= 5.63
(KJ/cycle)

Cycle 92 GMT 12/ 9/2021 10:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 31 14.99 519 241 0.24 / 518.22 5 35
2 7 2015.08 41 14.48 3269 1941 2.18 / 520.16 35 71
3 13 1825.96 20 14.53 3005 873 3.06 / 521.03 5 79
4 13 1225.20 20 14.67 2170 637 3.69 / 521.67 5 93
5 13 641.16 20 14.88 1335 397 4.09 / 522.07 5 99
6 8 0.16 280 15.06 343 1446 5.54 / 523.51 5 133
Average= 5.63
(KJ/cycle)

Cycle 91 GMT 2/ 9/2021 12:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 31 14.99 510 237 0.24 / 512.82 5 35
2 7 2006.96 40 14.50 3262 1892 2.13 / 514.71 35 68
3 13 1729.48 20 14.55 2888 840 2.97 / 515.55 5 82
4 13 1184.36 20 14.70 2123 624 3.59 / 516.18 5 92
5 13 604.04 20 14.90 1280 381 3.97 / 516.56 5 98
6 8 0.08 285 15.07 331 1422 5.40 / 517.98 5 137
Average= 5.63
(KJ/cycle)

Cycle 90 GMT 23/ 8/2021 15: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 31 15.00 491 228 0.23 / 507.42 5 35
2 7 2011.16 40 14.50 3261 1891 2.12 / 509.31 35 70
3 13 1722.24 20 14.56 2883 840 2.96 / 510.15 5 82
4 13 1164.68 20 14.70 2101 618 3.58 / 510.77 5 95
5 13 482.28 20 14.95 1106 331 3.91 / 511.10 5 97
6 13 109.44 20 15.10 518 156 4.06 / 511.25 5 87
7 8 0.08 261 15.06 338 1329 5.39 / 512.58 5 130
Average= 5.63
(KJ/cycle)

Cycle 89 GMT 13/ 8/2021 17:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 31 15.00 495 230 0.23 / 502.17 5 37
2 7 2011.36 40 14.50 3269 1896 2.13 / 504.06 37 69
3 13 1644.56 20 14.59 2742 800 2.93 / 504.86 5 83
4 13 1188.60 20 14.69 2109 620 3.55 / 505.48 5 94
5 13 503.80 20 14.94 1115 333 3.88 / 505.81 5 101
6 13 121.00 20 15.10 515 156 4.03 / 505.97 5 91
7 8 0.12 253 15.07 320 1220 5.25 / 507.19 5 132
Average= 5.64
(KJ/cycle)

Cycle 88 GMT 3/ 8/2021 19:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 32 15.00 508 244 0.24 / 496.77 5 37
2 7 2003.48 40 14.49 3258 1888 2.13 / 498.66 37 70
3 13 1810.84 20 14.54 2995 871 3.00 / 499.53 5 82
4 13 1122.28 20 14.72 2025 596 3.60 / 500.13 5 94
5 13 625.84 20 14.89 1289 384 3.98 / 500.51 5 98
6 13 115.28 20 15.10 503 152 4.14 / 500.66 5 91
7 8 -0.12 259 15.06 326 1272 5.41 / 501.94 5 131
Average= 5.64
(KJ/cycle)

Cycle 87 GMT 24/ 7/2021 22: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 32 15.01 509 244 0.24 / 491.33 5 35
2 7 2004.52 40 14.49 3280 1901 2.15 / 493.23 35 71
3 13 1820.48 20 14.53 3016 876 3.02 / 494.11 5 80
4 13 1137.88 20 14.71 2065 608 3.63 / 494.72 5 95
5 13 466.56 20 14.96 1083 324 3.95 / 495.04 5 99
6 13 171.16 20 15.08 603 182 4.14 / 495.22 5 95
7 8 0.00 262 15.06 331 1306 5.44 / 496.53 5 140
Average= 5.64
(KJ/cycle)

Cycle 86 GMT 15/ 7/2021 0:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 32 15.00 513 246 0.25 / 485.92 5 32
2 7 2003.92 40 14.49 3269 1895 2.14 / 487.82 6 69
3 13 1807.36 20 14.53 3000 872 3.01 / 488.69 5 78
4 13 1229.92 20 14.68 2178 639 3.65 / 489.33 5 92
5 13 469.56 20 14.96 1086 325 3.98 / 489.65 5 97
6 8 0.20 283 15.08 336 1434 5.41 / 491.09 5 134
Average= 5.64
(KJ/cycle)

Cycle 85 GMT 5/ 7/2021 2:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 30 15.00 502 226 0.23 / 480.48 5 30
2 3 1038.84 1 15.00 1948 29 0.26 / 480.51 5 37
3 7 2003.56 40 14.49 3282 1902 2.16 / 482.41 37 71
4 13 1710.44 20 14.56 2867 835 2.99 / 483.24 5 81
5 13 1056.56 20 14.74 1955 576 3.57 / 483.82 5 95
6 13 498.24 20 14.95 1130 338 3.91 / 484.16 5 99
7 13 109.96 20 15.11 511 154 4.06 / 484.31 5 89
8 8 0.04 263 15.06 344 1363 5.42 / 485.68 5 129
Average= 5.65
(KJ/cycle)

Cycle 84 GMT 25/ 6/2021 5:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 30 15.00 495 223 0.22 / 475.02 5 28
2 7 2003.68 40 14.50 3257 1889 2.11 / 476.91 28 71
3 13 1819.28 20 14.53 3011 875 2.99 / 477.79 5 79
4 13 1076.12 20 14.74 1971 581 3.57 / 478.37 5 95
5 13 681.00 20 14.87 1396 415 3.98 / 478.78 5 99
6 8 0.20 285 15.07 342 1469 5.45 / 480.25 5 135
Average= 5.65
(KJ/cycle)

Cycle 83 GMT 15/ 6/2021 7:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 32 14.90 491 234 0.23 / 469.65 5 29
2 3 948.36 -1 15.36 0 0 0.00 / 469.65 5 29
3 7 2007.64 40 14.52 3261 1894 2.13 / 471.54 29 70
4 13 1803.60 20 14.56 2998 873 3.00 / 472.42 5 79
5 13 1144.60 20 14.72 2082 613 3.61 / 473.03 5 95
6 13 466.60 20 14.96 1098 329 3.94 / 473.36 5 97
7 8 0.20 283 15.08 338 1442 5.39 / 474.80 5 135
Average= 5.65
(KJ/cycle)

Cycle 82 GMT 5/ 6/2021 9:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 32 14.91 499 238 0.24 / 463.90 5 26
2 7 2012.88 40 14.51 3290 1910 2.15 / 465.81 26 70
3 13 1921.48 20 14.49 3168 918 3.07 / 466.73 5 77
4 13 1392.76 20 14.53 2426 705 3.77 / 467.43 5 87
5 13 963.24 20 14.62 1810 529 4.30 / 467.96 5 97
6 13 166.96 20 14.90 623 186 4.49 / 468.15 5 95
7 8 0.12 261 14.90 326 1268 5.75 / 469.42 5 131
Average= 5.66
(KJ/cycle)

Cycle 81 GMT 26/ 5/2021 12:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 32 14.91 480 229 0.23 / 458.26 5 24
2 7 2014.36 40 14.52 3273 1901 2.13 / 460.16 24 70
3 13 1919.00 20 14.49 3183 922 3.05 / 461.08 5 75
4 13 1300.36 20 14.56 2303 671 3.72 / 461.75 5 89
5 13 781.20 20 14.68 1558 457 4.18 / 462.21 5 99
6 13 139.28 20 14.92 571 170 4.35 / 462.38 5 94
7 8 0.04 265 14.91 324 1280 5.63 / 463.66 5 143
Average= 5.65
(KJ/cycle)

Cycle 80 GMT 16/ 5/2021 15: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 32 14.90 509 243 0.24 / 452.55 5 25
2 7 2012.80 41 14.51 3267 1944 2.19 / 454.49 25 71
3 13 1915.52 20 14.51 3147 913 3.10 / 455.41 5 77
4 13 1473.60 20 14.53 2531 736 3.84 / 456.14 5 89
5 13 727.52 20 14.71 1465 431 4.27 / 456.57 5 97
6 13 190.64 20 14.90 652 194 4.46 / 456.77 5 96
7 8 0.04 263 14.91 322 1263 5.72 / 458.03 5 131
Average= 5.65
(KJ/cycle)

Cycle 79 GMT 6/ 5/2021 17:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 32 14.92 503 240 0.24 / 446.61 5 25
2 7 2010.84 40 14.52 3278 1904 2.14 / 448.52 25 71
3 13 1922.04 20 14.51 3168 919 3.06 / 449.44 5 75
4 13 1608.72 20 14.50 2714 787 3.85 / 450.22 5 86
5 13 817.60 20 14.67 1622 476 4.33 / 450.70 5 98
6 13 272.48 20 14.86 806 240 4.57 / 450.94 5 98
7 8 0.20 270 14.90 340 1368 5.93 / 452.31 5 133
Average= 5.65
(KJ/cycle)

Cycle 78 GMT 26/ 4/2021 20:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 32 14.91 487 232 0.23 / 440.85 5 28
2 7 2009.20 40 14.52 3278 1904 2.14 / 442.75 28 68
3 13 1928.92 20 14.51 3197 928 3.06 / 443.68 5 77
4 13 1486.92 20 14.52 2565 745 3.81 / 444.43 5 86
5 13 830.96 20 14.67 1641 481 4.29 / 444.91 5 98
6 13 191.88 20 14.90 675 201 4.49 / 445.11 5 95
7 8 0.00 261 14.92 325 1266 5.76 / 446.37 5 130
Average= 5.65
(KJ/cycle)

Cycle 77 GMT 16/ 4/2021 23:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 31 14.91 515 238 0.24 / 435.06 5 26
2 3 1047.32 1 15.00 1941 29 0.27 / 435.09 5 55
3 7 2003.64 40 14.52 3245 1885 2.15 / 436.98 55 70
4 13 1915.28 20 14.50 3174 920 3.07 / 437.90 5 76
5 13 1489.52 20 14.52 2565 745 3.82 / 438.64 5 89
6 13 819.92 20 14.68 1613 474 4.29 / 439.12 5 97
7 13 266.72 20 14.87 780 232 4.52 / 439.35 5 99
8 8 0.04 267 14.91 319 1270 5.79 / 440.62 5 135
Average= 5.65
(KJ/cycle)

Cycle 76 GMT 7/ 4/2021 2: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 32 14.91 502 240 0.24 / 429.44 5 25
2 3 959.32 -1 15.37 0 0 0.00 / 429.44 5 25
3 7 2003.64 40 14.52 3266 1897 2.14 / 431.34 25 73
4 13 1910.24 20 14.51 3150 914 3.05 / 432.26 5 79
5 13 1291.12 20 14.57 2295 669 3.72 / 432.92 5 91
6 13 763.92 20 14.70 1530 450 4.17 / 433.37 5 96
7 13 214.96 20 14.89 684 204 4.37 / 433.58 5 97
8 8 0.04 259 14.91 323 1247 5.62 / 434.82 5 132
Average= 5.65
(KJ/cycle)

Cycle 75 GMT 28/ 3/2021 4:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 32 14.92 497 237 0.24 / 423.52 5 23
2 7 2010.52 40 14.53 3276 1904 2.14 / 425.43 23 70
3 13 1922.52 20 14.51 3176 922 3.06 / 426.35 5 77
4 13 1590.44 20 14.51 2704 785 3.85 / 427.13 5 84
5 13 910.56 20 14.65 1749 512 4.36 / 427.65 5 96
6 13 254.92 20 14.87 784 233 4.59 / 427.88 5 97
7 13 30.16 20 14.96 386 115 4.71 / 427.99 5 85
8 8 0.16 246 14.91 330 1210 5.92 / 429.20 5 133
Average= 5.65
(KJ/cycle)

Cycle 74 GMT 18/ 3/2021 7:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 32 14.92 508 243 0.24 / 417.57 5 26
2 7 2005.52 41 14.52 3269 1946 2.19 / 419.52 26 69
3 13 1913.48 20 14.51 3177 922 3.11 / 420.44 5 78
4 13 1478.20 20 14.53 2564 745 3.86 / 421.18 5 88
5 13 1036.20 20 14.61 1936 566 4.42 / 421.75 5 95
6 13 235.56 20 14.89 744 222 4.64 / 421.97 5 96
7 8 0.08 270 14.92 326 1313 5.96 / 423.29 5 134
Average= 5.64
(KJ/cycle)

Cycle 73 GMT 8/ 3/2021 10:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 32 14.92 514 245 0.25 / 411.83 5 27
2 7 2014.60 40 14.53 3272 1902 2.15 / 413.74 27 71
3 13 1931.60 20 14.51 3153 915 3.06 / 414.65 5 78
4 13 1404.64 20 14.55 2440 710 3.77 / 415.36 5 88
5 13 861.92 20 14.67 1662 488 4.26 / 415.85 5 96
6 13 201.28 20 14.90 683 204 4.46 / 416.05 5 94
7 8 -0.04 265 14.92 323 1277 5.74 / 417.33 5 129
Average= 5.64
(KJ/cycle)

Cycle 72 GMT 26/ 2/2021 13:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 32 14.92 511 244 0.24 / 406.12 5 29
2 7 2004.84 40 14.54 3269 1901 2.15 / 408.03 29 71
3 13 1924.80 20 14.52 3160 918 3.06 / 408.94 5 78
4 13 1490.00 20 14.54 2562 745 3.81 / 409.69 5 86
5 13 733.20 20 14.72 1477 435 4.24 / 410.12 5 97
6 13 197.96 20 14.92 660 197 4.44 / 410.32 5 96
7 8 0.04 263 14.93 323 1268 5.71 / 411.59 5 135
Average= 5.64
(KJ/cycle)

Cycle 71 GMT 16/ 2/2021 16: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 32 14.93 508 243 0.24 / 400.14 5 28
2 7 2010.04 41 14.54 3271 1950 2.19 / 402.09 28 71
3 13 1911.12 20 14.52 3156 917 3.11 / 403.00 5 77
4 13 1585.48 20 14.52 2690 781 3.89 / 403.78 5 83
5 13 921.76 20 14.66 1772 520 4.41 / 404.30 5 97
6 13 242.88 20 14.90 766 228 4.64 / 404.53 5 96
7 8 0.12 265 14.93 341 1349 5.99 / 405.88 5 133
Average= 5.64
(KJ/cycle)

Cycle 70 GMT 6/ 2/2021 19: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 32 14.93 513 245 0.25 / 394.30 5 29
2 7 2006.92 40 14.54 3260 1896 2.14 / 396.20 17 71
3 13 1924.92 20 14.53 3168 921 3.06 / 397.12 5 76
4 13 1495.56 20 14.54 2578 750 3.81 / 397.87 5 86
5 13 836.12 20 14.69 1633 480 4.29 / 398.35 5 98
6 13 278.84 20 14.88 815 243 4.53 / 398.59 5 97
7 8 0.12 264 14.93 331 1305 5.84 / 399.89 5 132
Average= 5.63
(KJ/cycle)

Cycle 69 GMT 27/ 1/2021 21:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 31 14.94 491 227 0.23 / 388.53 5 29
2 3 1044.52 1 15.03 1934 29 0.26 / 388.56 5 45
3 7 2012.00 40 14.55 3272 1904 2.16 / 390.47 45 71
4 13 1921.04 20 14.53 3154 917 3.08 / 391.38 5 77
5 13 1395.52 20 14.56 2445 712 3.79 / 392.10 5 89
6 13 852.88 20 14.69 1650 485 4.27 / 392.58 5 95
7 13 192.60 20 14.93 658 196 4.47 / 392.78 5 95
8 8 0.04 265 14.94 323 1279 5.75 / 394.06 5 131
Average= 5.63
(KJ/cycle)

Cycle 68 GMT 18/ 1/2021 0:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 32 14.94 482 230 0.23 / 382.74 5 33
2 3 950.04 -1 15.38 0 0 0.00 / 382.74 5 33
3 7 2010.52 40 14.55 3283 1911 2.14 / 384.65 33 70
4 13 1912.88 20 14.54 3157 918 3.06 / 385.56 5 76
5 13 1472.56 20 14.55 2565 746 3.81 / 386.31 5 86
6 13 724.40 20 14.74 1479 436 4.24 / 386.75 5 97
7 13 279.08 20 14.89 816 243 4.48 / 386.99 5 98
8 8 0.04 267 14.94 330 1316 5.80 / 388.31 5 135
Average= 5.63
(KJ/cycle)

Cycle 67 GMT 8/ 1/2021 3:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 32 14.94 519 248 0.25 / 377.10 5 30
2 7 2004.44 40 14.55 3254 1894 2.14 / 379.00 30 71
3 13 1911.36 20 14.54 3143 914 3.06 / 379.91 5 75
4 13 1385.92 20 14.58 2413 704 3.76 / 380.61 5 89
5 13 732.64 20 14.74 1482 437 4.20 / 381.05 5 95
6 13 199.64 20 14.93 673 201 4.40 / 381.25 5 94
7 8 0.08 261 14.95 321 1253 5.65 / 382.50 5 130
Average= 5.63
(KJ/cycle)

Cycle 66 GMT 29/12/2020 6:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 32 14.94 518 248 0.25 / 371.30 5 33
2 7 2003.84 40 14.55 3274 1905 2.15 / 373.20 33 70
3 13 1912.52 20 14.53 3175 923 3.08 / 374.13 5 78
4 13 1468.28 20 14.56 2545 741 3.82 / 374.87 5 86
5 13 797.12 20 14.72 1584 466 4.28 / 375.33 5 98
6 13 231.88 20 14.92 736 220 4.50 / 375.55 5 98
7 8 0.08 263 14.95 331 1301 5.80 / 376.85 5 135
Average= 5.62
(KJ/cycle)

Cycle 65 GMT 19/12/2020 9:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 32 14.95 499 239 0.24 / 365.43 5 32
2 7 2003.64 40 14.54 3281 1908 2.15 / 367.34 32 70
3 13 1909.68 20 14.53 3159 918 3.06 / 368.26 5 77
4 13 1379.40 20 14.59 2412 704 3.77 / 368.96 5 90
5 13 941.80 20 14.67 1797 527 4.30 / 369.49 5 96
6 13 254.32 20 14.91 779 232 4.53 / 369.72 5 97
7 8 0.16 266 14.95 334 1328 5.86 / 371.05 5 134
Average= 5.62
(KJ/cycle)

Cycle 64 GMT 9/12/2020 12:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 32 14.95 519 248 0.25 / 359.78 5 30
2 7 2012.32 40 14.56 3277 1909 2.16 / 361.69 30 71
3 13 1915.64 20 14.55 3156 918 3.08 / 362.61 5 78
4 13 1267.88 20 14.62 2252 658 3.73 / 363.27 5 90
5 13 752.28 20 14.75 1503 443 4.18 / 363.71 5 97
6 13 204.20 20 14.94 688 206 4.38 / 363.92 5 96
7 8 0.12 261 14.96 327 1277 5.66 / 365.19 5 130
Average= 5.62
(KJ/cycle)

Cycle 63 GMT 29/11/2020 15: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 32 14.96 491 235 0.24 / 354.09 5 33
2 7 2005.52 40 14.55 3284 1911 2.15 / 356.00 33 71
3 13 1915.68 20 14.54 3168 921 3.07 / 356.92 5 76
4 13 1279.20 20 14.62 2255 659 3.73 / 357.58 5 90
5 13 746.04 20 14.75 1507 445 4.17 / 358.02 5 98
6 13 198.56 20 14.94 682 204 4.38 / 358.23 5 95
7 8 0.04 261 14.96 335 1308 5.68 / 359.53 5 132
Average= 5.62
(KJ/cycle)

Cycle 62 GMT 19/11/2020 17:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.00 32 14.96 510 244 0.24 / 348.49 5 31
2 7 2010.72 40 14.56 3273 1906 2.15 / 350.39 31 70
3 13 1920.60 20 14.54 3162 920 3.07 / 351.31 5 77
4 13 1306.12 20 14.61 2305 674 3.74 / 351.99 5 90
5 13 658.60 20 14.78 1374 406 4.15 / 352.39 5 100
6 13 135.32 20 14.98 571 171 4.32 / 352.56 5 91
7 8 0.04 263 14.97 327 1287 5.61 / 353.85 5 131
Average= 5.62
(KJ/cycle)

Cycle 61 GMT 9/11/2020 20:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 31 14.97 514 239 0.24 / 342.69 5 30
2 7 2006.48 40 14.57 3268 1905 2.14 / 344.60 30 71
3 13 1914.40 20 14.56 3146 916 3.06 / 345.51 5 77
4 13 1508.76 20 14.57 2603 759 3.82 / 346.27 5 88
5 13 747.52 20 14.77 1502 444 4.26 / 346.71 5 98
6 13 213.24 20 14.96 694 208 4.47 / 346.92 5 93
7 8 0.12 268 14.98 329 1321 5.79 / 348.24 5 141
Average= 5.62
(KJ/cycle)

Cycle 60 GMT 30/10/2020 22:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 32 14.98 512 245 0.25 / 337.00 5 31
2 7 2014.64 40 14.57 3272 1907 2.15 / 338.91 31 71
3 13 1925.76 20 14.55 3170 922 3.07 / 339.83 5 77
4 13 1292.36 20 14.62 2296 671 3.75 / 340.50 5 92
5 13 766.08 20 14.76 1538 454 4.20 / 340.96 5 99
6 13 211.68 20 14.96 704 211 4.41 / 341.17 5 97
7 8 0.00 261 14.98 329 1286 5.70 / 342.45 5 135
Average= 5.61
(KJ/cycle)

Cycle 59 GMT 21/10/2020 1:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 31 14.98 520 241 0.24 / 331.17 5 32
2 7 2012.48 40 14.56 3291 1917 2.16 / 333.09 6 71
3 13 1919.28 20 14.56 3161 920 3.08 / 334.01 5 77
4 13 1473.44 20 14.58 2570 749 3.83 / 334.76 5 88
5 13 714.68 20 14.79 1477 437 4.26 / 335.19 5 97
6 13 263.36 20 14.95 784 234 4.50 / 335.43 5 98
7 8 0.04 266 14.99 333 1328 5.83 / 336.76 5 135
Average= 5.61
(KJ/cycle)

Cycle 58 GMT 11/10/2020 4:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 31 15.00 514 239 0.24 / 325.32 5 34
2 3 1032.28 1 15.08 1954 29 0.27 / 325.35 5 41
3 7 2013.48 40 14.58 3268 1906 2.17 / 327.26 41 72
4 13 1920.52 20 14.56 3160 920 3.09 / 328.18 5 79
5 13 1370.52 20 14.62 2411 705 3.80 / 328.88 5 89
6 13 835.04 20 14.75 1627 480 4.28 / 329.36 5 100
7 13 269.84 20 14.95 790 236 4.52 / 329.60 5 99
8 8 0.16 266 15.00 334 1333 5.85 / 330.93 5 130
Average= 5.61
(KJ/cycle)

Cycle 57 GMT 1/10/2020 7:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 31 15.00 505 235 0.23 / 319.61 5 34
2 7 2010.12 40 14.58 3261 1902 2.14 / 321.51 34 72
3 13 1917.64 20 14.57 3166 923 3.06 / 322.43 5 79
4 13 1389.12 20 14.62 2416 706 3.77 / 323.14 5 88
5 13 744.72 20 14.79 1497 443 4.21 / 323.58 5 99
6 13 199.76 20 14.99 681 204 4.41 / 323.79 5 98
7 8 0.12 259 15.00 333 1294 5.71 / 325.08 5 130
Average= 5.60
(KJ/cycle)

Cycle 56 GMT 21/ 9/2020 9:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.52 31 15.01 523 243 0.24 / 313.80 5 32
2 7 2005.36 40 14.58 3265 1904 2.15 / 315.70 32 71
3 13 1919.04 20 14.58 3140 916 3.06 / 316.62 5 78
4 13 1404.40 20 14.63 2438 713 3.78 / 317.33 5 89
5 13 951.72 20 14.72 1788 526 4.30 / 317.86 5 99
6 13 241.80 20 14.98 747 224 4.53 / 318.08 5 100
7 8 -0.04 263 15.01 328 1295 5.82 / 319.37 5 129
Average= 5.60
(KJ/cycle)

Cycle 55 GMT 11/ 9/2020 12:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 31 15.02 507 236 0.24 / 308.07 5 33
2 7 2009.08 40 14.59 3252 1898 2.13 / 309.96 33 72
3 13 1917.40 20 14.58 3164 923 3.06 / 310.89 5 77
4 13 1275.12 20 14.66 2266 664 3.72 / 311.55 5 92
5 13 760.40 20 14.80 1545 457 4.18 / 312.01 5 99
6 13 216.00 20 14.99 730 219 4.40 / 312.23 5 97
7 8 0.00 261 15.02 338 1325 5.72 / 313.55 5 137
Average= 5.60
(KJ/cycle)

Cycle 54 GMT 1/ 9/2020 15:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 31 15.02 505 235 0.24 / 302.31 5 33
2 7 2013.52 40 14.58 3283 1915 2.15 / 304.23 33 73
3 13 1914.84 20 14.58 3156 920 3.07 / 305.15 5 78
4 13 1283.60 20 14.67 2278 668 3.74 / 305.82 5 91
5 13 849.52 20 14.78 1649 487 4.23 / 306.30 5 100
6 13 274.60 20 14.98 801 240 4.47 / 306.54 5 99
7 13 13.72 20 15.08 358 108 4.57 / 306.65 5 84
8 8 0.04 238 15.02 330 1180 5.75 / 307.83 5 131
Average= 5.60
(KJ/cycle)

Cycle 53 GMT 22/ 8/2020 18:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 31 15.03 530 247 0.25 / 296.51 5 31
2 7 2007.12 40 14.59 3267 1907 2.15 / 298.41 31 72
3 13 1915.28 20 14.58 3166 923 3.08 / 299.34 5 79
4 13 1390.72 20 14.64 2424 710 3.79 / 300.05 5 90
5 13 752.48 20 14.82 1521 451 4.24 / 300.50 5 99
6 13 307.04 20 14.97 853 255 4.49 / 300.75 5 100
7 8 0.08 266 15.03 331 1323 5.82 / 302.08 5 139
Average= 5.59
(KJ/cycle)

Cycle 52 GMT 12/ 8/2020 20:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 31 15.04 514 240 0.24 / 290.84 5 29
2 7 2004.60 40 14.60 3266 1907 2.15 / 292.75 29 72
3 13 1913.68 20 14.58 3148 918 3.06 / 293.67 5 78
4 13 1385.72 20 14.65 2418 708 3.77 / 294.38 5 89
5 13 630.88 20 14.88 1348 401 4.17 / 294.78 5 99
6 13 209.64 20 15.03 684 206 4.38 / 294.98 5 97
7 8 0.04 259 15.05 328 1279 5.66 / 296.26 5 130
Average= 5.59
(KJ/cycle)

Cycle 51 GMT 2/ 8/2020 23:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 31 15.06 513 239 0.24 / 284.99 5 28
2 7 2006.04 40 14.59 3287 1918 2.16 / 286.91 28 71
3 13 1918.56 20 14.59 3156 921 3.08 / 287.83 5 79
4 13 1469.16 20 14.63 2555 748 3.83 / 288.58 5 88
5 13 797.32 20 14.82 1594 472 4.30 / 289.05 5 98
6 13 227.52 20 15.02 737 221 4.52 / 289.27 5 98
7 8 0.12 261 15.05 338 1328 5.85 / 290.60 5 130
Average= 5.59
(KJ/cycle)

Cycle 50 GMT 24/ 7/2020 2:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 31 15.06 501 234 0.23 / 279.25 5 28
2 7 2009.88 40 14.60 3265 1907 2.14 / 281.16 28 72
3 13 1915.64 20 14.59 3173 926 3.07 / 282.08 5 78
4 13 1469.60 20 14.64 2550 747 3.81 / 282.83 5 88
5 13 688.60 20 14.88 1409 419 4.23 / 283.25 5 99
6 13 251.60 20 15.03 756 227 4.46 / 283.48 5 98
7 8 0.04 261 15.07 325 1278 5.74 / 284.75 5 134
Average= 5.58
(KJ/cycle)

Cycle 49 GMT 14/ 7/2020 5:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 31 15.07 494 231 0.23 / 273.37 5 24
2 7 2006.56 40 14.60 3252 1899 2.13 / 275.27 24 71
3 13 1916.52 20 14.60 3139 917 3.05 / 276.19 5 79
4 13 1593.60 20 14.61 2699 789 3.84 / 276.98 5 86
5 13 797.64 20 14.84 1569 466 4.30 / 277.44 5 98
6 13 348.24 20 14.99 916 275 4.58 / 277.72 5 100
7 8 0.04 267 15.07 323 1300 5.88 / 279.02 5 130
Average= 5.58
(KJ/cycle)

Cycle 48 GMT 4/ 7/2020 8: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 31 15.08 505 236 0.24 / 267.54 5 25
2 7 2005.28 40 14.61 3266 1909 2.14 / 269.45 25 71
3 13 1915.04 20 14.61 3143 918 3.06 / 270.37 5 79
4 13 1302.68 20 14.71 2300 677 3.74 / 271.04 5 92
5 13 966.16 20 14.78 1823 539 4.28 / 271.58 5 99
6 13 277.84 20 15.02 809 243 4.52 / 271.83 5 100
7 13 34.12 20 15.11 391 118 4.64 / 271.94 5 84
8 8 0.00 246 15.07 323 1197 5.84 / 273.14 5 134
Average= 5.57
(KJ/cycle)

Cycle 47 GMT 24/ 6/2020 10:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 31 15.09 498 233 0.23 / 261.85 5 24
2 7 2011.64 40 14.60 3281 1916 2.15 / 263.76 24 72
3 13 1819.48 20 14.63 3022 884 3.03 / 264.65 5 80
4 13 1495.76 20 14.65 2580 756 3.79 / 265.40 5 89
5 13 710.28 20 14.88 1454 433 4.22 / 265.83 5 99
6 13 173.12 20 15.08 630 190 4.41 / 266.02 5 94
7 8 0.04 261 15.09 325 1280 5.69 / 267.30 5 132
Average= 5.57
(KJ/cycle)

Cycle 46 GMT 14/ 6/2020 13:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 31 15.10 478 224 0.22 / 256.31 5 24
2 7 2005.20 40 14.61 3259 1905 2.13 / 258.21 24 73
3 13 1824.12 20 14.63 3019 883 3.01 / 259.10 5 82
4 13 1316.60 20 14.71 2325 684 3.70 / 259.78 5 92
5 13 671.60 20 14.91 1396 416 4.11 / 260.20 5 100
6 13 128.64 20 15.11 554 167 4.28 / 260.36 5 91
7 8 -0.04 261 15.10 317 1249 5.53 / 261.61 5 133
Average= 5.57
(KJ/cycle)

Cycle 45 GMT 4/ 6/2020 16:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.16 31 15.10 498 233 0.23 / 250.67 5 21
2 7 2012.00 40 14.61 3269 1910 2.14 / 252.58 21 73
3 13 1913.52 20 14.62 3146 920 3.06 / 253.50 5 80
4 13 1278.40 20 14.73 2274 670 3.73 / 254.17 5 92
5 13 753.12 20 14.89 1511 450 4.18 / 254.62 5 100
6 13 205.36 20 15.08 681 205 4.39 / 254.83 5 96
7 8 0.04 257 15.10 323 1253 5.64 / 256.08 5 151
Average= 5.57
(KJ/cycle)

Cycle 44 GMT 25/ 5/2020 18:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 31 15.11 476 223 0.22 / 244.96 5 26
2 7 2005.04 40 14.62 3268 1911 2.13 / 246.88 26 72
3 13 1915.00 20 14.62 3155 923 3.06 / 247.80 5 79
4 13 1390.12 20 14.71 2429 715 3.77 / 248.51 5 91
5 13 737.72 20 14.89 1491 444 4.22 / 248.96 5 99
6 13 188.36 20 15.09 667 201 4.42 / 249.16 5 96
7 8 0.08 259 15.10 328 1283 5.70 / 250.44 5 129
Average= 5.57
(KJ/cycle)

Cycle 43 GMT 15/ 5/2020 21:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 31 15.12 495 232 0.23 / 239.40 5 22
2 7 2011.48 40 14.63 3279 1919 2.15 / 241.32 22 72
3 13 1813.32 20 14.64 3016 883 3.03 / 242.20 5 82
4 13 1286.76 20 14.74 2288 675 3.71 / 242.88 5 94
5 13 757.32 20 14.89 1532 456 4.16 / 243.33 5 99
6 13 201.44 20 15.10 679 205 4.37 / 243.54 5 97
7 8 0.04 244 15.11 326 1202 5.57 / 244.74 5 130
Average= 5.56
(KJ/cycle)

Cycle 42 GMT 6/ 5/2020 0: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 31 15.12 501 235 0.23 / 233.71 5 21
2 7 2012.20 41 14.62 3278 1965 2.20 / 235.68 21 71
3 13 1914.24 20 14.62 3166 926 3.13 / 236.60 5 79
4 13 1278.88 20 14.74 2285 674 3.80 / 237.28 5 94
5 13 644.00 20 14.94 1357 405 4.20 / 237.68 5 102
6 13 215.52 20 15.09 709 214 4.42 / 237.90 5 99
7 8 0.04 261 15.12 323 1275 5.69 / 239.17 5 130
Average= 5.56
(KJ/cycle)

Cycle 41 GMT 26/ 4/2020 2:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 31 15.13 506 237 0.24 / 228.00 5 21
2 7 2005.40 40 14.63 3265 1911 2.15 / 229.91 21 73
3 13 1913.60 20 14.64 3135 918 3.07 / 230.83 5 77
4 13 1464.80 20 14.70 2544 748 3.81 / 231.58 5 90
5 13 702.68 20 14.93 1445 431 4.25 / 232.01 5 98
6 13 160.68 20 15.12 618 187 4.43 / 232.20 5 93
7 8 0.08 257 15.13 329 1279 5.71 / 233.48 5 134
Average= 5.56
(KJ/cycle)

Cycle 40 GMT 16/ 4/2020 5:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 31 15.13 487 228 0.23 / 222.21 5 22
2 7 2008.56 41 14.64 3244 1947 2.18 / 224.15 22 73
3 13 1918.44 20 14.64 3149 922 3.10 / 225.08 5 80
4 13 1468.00 20 14.71 2530 744 3.84 / 225.82 5 91
5 13 684.20 20 14.94 1405 420 4.26 / 226.24 5 99
6 13 235.40 20 15.10 740 223 4.49 / 226.46 5 97
7 8 0.08 263 15.13 327 1301 5.79 / 227.77 5 131
Average= 5.56
(KJ/cycle)

Cycle 39 GMT 6/ 4/2020 7:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 31 15.13 498 234 0.23 / 216.70 5 19
2 7 2006.08 40 14.63 3267 1912 2.15 / 218.61 19 72
3 13 1913.64 20 14.64 3162 926 3.07 / 219.54 5 79
4 13 1173.04 20 14.80 2116 626 3.70 / 220.16 5 96
5 13 550.80 20 15.00 1209 363 4.06 / 220.52 5 102
6 13 137.36 20 15.14 570 173 4.23 / 220.70 5 95
7 8 0.04 259 15.14 327 1282 5.52 / 221.98 5 136
Average= 5.55
(KJ/cycle)

Cycle 38 GMT 27/ 3/2020 10: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 31 15.13 510 239 0.24 / 210.98 5 19
2 7 2011.28 40 14.65 3266 1914 2.15 / 212.90 19 73
3 13 1914.08 20 14.64 3151 923 3.08 / 213.82 5 79
4 13 1384.76 20 14.74 2418 713 3.79 / 214.53 5 92
5 13 713.76 20 14.94 1461 437 4.23 / 214.97 5 102
6 13 159.08 20 15.14 612 185 4.41 / 215.15 5 95
7 8 -0.04 259 15.14 334 1310 5.72 / 216.46 5 130
Average= 5.55
(KJ/cycle)

Cycle 37 GMT 17/ 3/2020 12:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 31 15.14 494 232 0.23 / 205.04 5 24
2 7 2013.40 40 14.65 3282 1923 2.16 / 206.96 24 72
3 13 1919.20 20 14.66 3158 926 3.08 / 207.89 5 79
4 13 1378.36 20 14.75 2437 719 3.80 / 208.61 5 92
5 13 937.44 20 14.86 1803 536 4.34 / 209.14 5 100
6 13 235.84 20 15.10 761 230 4.57 / 209.37 5 100
7 8 0.12 261 15.14 347 1371 5.94 / 210.74 5 130
Average= 5.55
(KJ/cycle)

Cycle 36 GMT 7/ 3/2020 15:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 31 15.14 505 237 0.24 / 199.33 5 23
2 7 2007.76 40 14.65 3266 1914 2.15 / 201.24 23 73
3 13 1920.72 20 14.67 3157 926 3.08 / 202.17 5 80
4 13 1367.20 20 14.76 2380 703 3.78 / 202.87 5 93
5 13 724.00 20 14.95 1467 439 4.22 / 203.31 5 101
6 13 179.00 20 15.14 645 195 4.41 / 203.50 5 99
7 8 0.08 259 15.15 332 1303 5.72 / 204.81 5 135
Average= 5.54
(KJ/cycle)

Cycle 35 GMT 26/ 2/2020 17:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 31 15.15 513 241 0.24 / 193.58 5 20
2 7 2012.32 40 14.64 3287 1925 2.17 / 195.51 20 74
3 13 1918.48 20 14.66 3158 926 3.09 / 196.43 5 80
4 13 1381.92 20 14.76 2420 714 3.81 / 197.15 5 92
5 13 629.20 20 14.98 1350 404 4.21 / 197.55 5 101
6 13 191.12 20 15.14 678 205 4.42 / 197.76 5 99
7 8 0.12 261 15.15 337 1333 5.75 / 199.09 5 131
Average= 5.53
(KJ/cycle)

Cycle 34 GMT 16/ 2/2020 20: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 31 15.16 494 232 0.23 / 187.85 5 22
2 7 2006.12 40 14.66 3272 1919 2.15 / 189.77 22 73
3 13 1919.16 20 14.67 3140 921 3.07 / 190.69 5 80
4 13 1278.48 20 14.80 2265 670 3.74 / 191.36 5 94
5 13 642.64 20 14.98 1359 407 4.15 / 191.77 5 101
6 13 306.76 20 15.09 859 259 4.41 / 192.03 5 101
7 8 -0.04 265 15.15 327 1313 5.72 / 193.34 5 136
Average= 5.52
(KJ/cycle)

Cycle 33 GMT 6/ 2/2020 22:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.84 31 15.15 499 234 0.23 / 182.09 5 23
2 7 2011.20 40 14.66 3285 1926 2.16 / 184.01 23 73
3 13 1920.08 20 14.66 3166 928 3.09 / 184.94 5 79
4 13 1397.36 20 14.76 2437 719 3.81 / 185.66 5 92
5 13 748.80 20 14.95 1500 448 4.26 / 186.11 5 101
6 13 203.28 20 15.14 676 205 4.46 / 186.31 5 98
7 8 0.08 265 15.16 325 1306 5.77 / 187.62 5 136
Average= 5.52
(KJ/cycle)

Cycle 32 GMT 28/ 1/2020 0:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 31 15.15 512 240 0.24 / 176.26 5 27
2 7 2004.80 40 14.66 3270 1918 2.16 / 178.18 27 73
3 13 1913.48 20 14.67 3164 928 3.09 / 179.11 5 80
4 13 1374.76 20 14.78 2403 710 3.80 / 179.82 5 93
5 13 923.08 20 14.89 1760 524 4.32 / 180.34 5 100
6 13 232.96 20 15.13 740 224 4.54 / 180.57 5 101
7 8 0.12 261 15.17 325 1287 5.83 / 181.85 5 131
Average= 5.51
(KJ/cycle)

Cycle 31 GMT 18/ 1/2020 3:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.00 31 15.16 526 247 0.25 / 170.41 5 24
2 7 2004.32 40 14.67 3252 1908 2.16 / 172.32 24 72
3 13 1908.64 20 14.68 3155 926 3.08 / 173.24 5 79
4 13 1449.56 20 14.76 2511 741 3.82 / 173.99 5 91
5 13 879.96 20 14.91 1705 508 4.33 / 174.49 5 100
6 13 208.72 20 15.15 696 211 4.54 / 174.71 5 99
7 8 0.12 263 15.17 330 1317 5.86 / 176.02 5 133
Average= 5.50
(KJ/cycle)

Cycle 30 GMT 8/ 1/2020 6:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 31 15.18 493 232 0.23 / 164.60 5 27
2 7 2003.20 40 14.67 3275 1922 2.15 / 166.52 27 72
3 13 1907.28 20 14.69 3133 920 3.07 / 167.44 5 80
4 13 1472.12 20 14.75 2538 749 3.82 / 168.19 5 90
5 13 690.76 20 14.98 1428 428 4.25 / 168.62 5 101
6 13 240.20 20 15.14 753 228 4.48 / 168.85 5 100
7 8 0.12 261 15.17 332 1315 5.79 / 170.16 5 130
Average= 5.49
(KJ/cycle)

Cycle 29 GMT 29/12/2019 9: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 31 15.17 502 236 0.24 / 158.85 5 26
2 7 2004.00 40 14.68 3269 1920 2.16 / 160.77 26 72
3 13 1911.68 20 14.68 3177 933 3.09 / 161.70 5 80
4 13 1363.36 20 14.78 2410 712 3.80 / 162.41 5 93
5 13 810.80 20 14.95 1606 480 4.28 / 162.89 5 101
6 13 154.44 20 15.18 597 181 4.46 / 163.07 5 94
7 8 0.00 263 15.18 325 1298 5.76 / 164.37 5 129
Average= 5.48
(KJ/cycle)

Cycle 28 GMT 19/12/2019 11:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 31 15.17 521 245 0.25 / 153.12 5 25
2 7 2005.88 40 14.68 3263 1916 2.16 / 155.04 25 73
3 13 1922.96 20 14.69 3163 929 3.09 / 155.97 5 80
4 13 1382.12 20 14.80 2401 711 3.80 / 156.68 5 92
5 13 731.28 20 14.98 1475 442 4.24 / 157.12 5 102
6 13 178.52 20 15.18 629 191 4.43 / 157.31 5 96
7 8 0.00 261 15.18 328 1300 5.73 / 158.61 5 132
Average= 5.47
(KJ/cycle)

Cycle 27 GMT 9/12/2019 14: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 30 15.18 523 238 0.24 / 147.14 5 26
2 7 2004.88 41 14.68 3280 1974 2.21 / 149.11 26 73
3 13 1912.16 20 14.70 3158 928 3.14 / 150.04 5 79
4 13 1463.12 20 14.77 2548 753 3.89 / 150.79 5 91
5 13 988.56 20 14.89 1860 554 4.45 / 151.35 5 100
6 13 181.04 20 15.18 647 196 4.64 / 151.55 5 96
7 8 0.08 261 15.18 336 1331 5.98 / 152.88 5 134
Average= 5.46
(KJ/cycle)

Cycle 26 GMT 29/11/2019 16:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 30 15.17 518 236 0.24 / 141.35 5 26
2 7 2005.64 41 14.68 3279 1974 2.21 / 143.32 26 73
3 13 1911.00 20 14.70 3162 930 3.14 / 144.25 5 80
4 13 1353.32 20 14.80 2394 709 3.85 / 144.96 5 93
5 13 597.12 20 15.03 1306 393 4.24 / 145.35 5 102
6 13 164.20 20 15.18 634 192 4.43 / 145.55 5 93
7 8 0.08 262 15.18 341 1356 5.79 / 146.90 5 137
Average= 5.44
(KJ/cycle)

Cycle 25 GMT 19/11/2019 19:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 30 15.18 525 239 0.24 / 135.62 5 26
2 7 2005.52 40 14.69 3279 1927 2.17 / 137.54 5 73
3 13 1914.40 20 14.71 3161 930 3.10 / 138.47 5 79
4 13 1274.40 20 14.84 2270 674 3.77 / 139.15 5 95
5 13 748.40 20 14.98 1519 455 4.22 / 139.60 5 101
6 13 198.92 20 15.17 681 207 4.43 / 139.81 5 95
7 8 0.08 261 15.19 329 1304 5.74 / 141.11 5 129
Average= 5.43
(KJ/cycle)

Cycle 24 GMT 9/11/2019 21:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 30 15.18 525 239 0.24 / 129.89 5 29
2 7 2008.72 40 14.69 3282 1929 2.17 / 131.82 29 75
3 13 1919.48 20 14.70 3175 933 3.10 / 132.75 5 80
4 13 1275.60 20 14.83 2277 675 3.78 / 133.43 5 95
5 13 624.92 20 15.03 1329 399 4.18 / 133.83 5 101
6 13 188.36 20 15.18 663 201 4.38 / 134.03 5 96
7 8 0.04 263 15.19 338 1350 5.73 / 135.38 5 135
Average= 5.42
(KJ/cycle)

Cycle 23 GMT 31/10/2019 0:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 30 15.18 530 241 0.24 / 124.10 5 27
2 7 2005.32 40 14.70 3275 1926 2.17 / 126.02 27 74
3 13 1919.04 20 14.72 3161 931 3.10 / 126.95 5 80
4 13 1374.40 20 14.81 2422 717 3.82 / 127.67 5 93
5 13 715.32 20 15.00 1475 442 4.26 / 128.11 5 102
6 13 175.64 20 15.19 641 195 4.45 / 128.31 5 94
7 8 0.00 261 15.20 338 1341 5.79 / 129.65 5 138
Average= 5.40
(KJ/cycle)

Cycle 22 GMT 21/10/2019 2:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 30 15.19 518 236 0.24 / 118.23 5 25
2 7 2005.16 40 14.70 3277 1927 2.16 / 120.16 25 75
3 13 1919.20 20 14.72 3161 931 3.09 / 121.09 5 80
4 13 1304.20 20 14.84 2322 689 3.78 / 121.78 5 94
5 13 764.32 20 14.99 1527 458 4.24 / 122.24 5 101
6 13 211.40 20 15.18 704 214 4.45 / 122.45 5 98
7 13 17.00 20 15.24 372 113 4.57 / 122.56 5 83
8 8 0.00 251 15.19 339 1293 5.86 / 123.86 5 137
Average= 5.39
(KJ/cycle)

Cycle 21 GMT 11/10/2019 5: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 30 15.19 504 230 0.23 / 112.58 5 25
2 7 2008.16 40 14.71 3278 1929 2.16 / 114.51 25 75
3 13 1808.24 20 14.75 3029 894 3.05 / 115.40 5 83
4 13 1381.48 20 14.82 2408 714 3.77 / 116.11 5 92
5 13 612.64 20 15.05 1309 394 4.16 / 116.51 5 101
6 13 176.84 20 15.20 635 193 4.35 / 116.70 5 95
7 8 0.00 263 15.21 324 1296 5.65 / 118.00 5 131
Average= 5.36
(KJ/cycle)

Cycle 20 GMT 1/10/2019 7:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 30 15.20 512 233 0.23 / 106.84 5 25
2 7 2011.08 40 14.71 3289 1935 2.17 / 108.78 25 74
3 13 1912.24 20 14.73 3162 932 3.10 / 109.71 5 80
4 13 1367.36 20 14.83 2400 712 3.81 / 110.42 5 92
5 13 627.16 20 15.05 1325 399 4.21 / 110.82 5 101
6 13 95.76 20 15.23 507 154 4.37 / 110.98 5 89
7 8 0.08 265 15.21 340 1370 5.74 / 112.35 5 131
Average= 5.35
(KJ/cycle)

Cycle 19 GMT 21/ 9/2019 10: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 30 15.20 516 235 0.24 / 101.24 5 25
2 7 2011.04 40 14.72 3275 1928 2.16 / 103.17 25 75
3 13 1821.12 20 14.76 3032 895 3.06 / 104.07 5 83
4 13 1306.64 20 14.86 2299 683 3.74 / 104.75 5 95
5 13 573.60 20 15.07 1244 375 4.12 / 105.12 5 102
6 13 147.48 20 15.22 583 177 4.29 / 105.30 5 94
7 8 0.00 261 15.21 330 1310 5.60 / 106.61 5 136
Average= 5.33
(KJ/cycle)

Cycle 18 GMT 11/ 9/2019 12:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 30 15.20 511 233 0.23 / 95.41 5 25
2 7 2012.16 40 14.72 3305 1946 2.18 / 97.35 25 75
3 13 1915.20 20 14.74 3165 933 3.11 / 98.29 5 80
4 13 1491.16 20 14.81 2553 756 3.87 / 99.04 5 92
5 13 707.32 20 15.03 1441 433 4.30 / 99.47 5 101
6 13 167.56 20 15.21 625 190 4.49 / 99.66 5 95
7 8 0.16 265 15.21 333 1342 5.83 / 101.01 5 135
Average= 5.32
(KJ/cycle)

Cycle 17 GMT 1/ 9/2019 14:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 30 15.20 523 238 0.24 / 89.62 5 26
2 7 2012.72 40 14.73 3287 1937 2.18 / 91.55 26 75
3 13 1916.24 20 14.74 3172 935 3.11 / 92.49 5 80
4 13 1273.96 20 14.87 2275 677 3.79 / 93.17 5 95
5 13 744.68 20 15.01 1518 456 4.24 / 93.62 5 101
6 13 190.40 20 15.20 667 203 4.45 / 93.82 5 98
7 8 -0.04 264 15.21 336 1349 5.79 / 95.17 5 132
Average= 5.29
(KJ/cycle)

Cycle 16 GMT 22/ 8/2019 17:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 30 15.20 536 244 0.24 / 83.80 5 26
2 7 2008.76 40 14.73 3288 1937 2.18 / 85.74 26 76
3 13 1917.36 20 14.74 3178 937 3.12 / 86.68 5 80
4 13 1380.88 20 14.84 2424 719 3.84 / 87.40 5 94
5 13 610.36 20 15.06 1317 397 4.23 / 87.79 5 102
6 13 181.16 20 15.20 662 201 4.44 / 87.99 5 98
7 8 0.08 267 15.21 341 1385 5.82 / 89.38 5 134
Average= 5.26
(KJ/cycle)

Cycle 15 GMT 12/ 8/2019 19:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 30 15.21 521 238 0.24 / 77.97 5 25
2 7 2013.16 41 14.72 3300 1992 2.23 / 79.96 25 76
3 13 1926.52 20 14.75 3187 940 3.17 / 80.90 5 81
4 13 1275.24 20 14.87 2298 683 3.85 / 81.59 5 97
5 13 629.40 20 15.05 1342 404 4.26 / 81.99 5 103
6 13 202.44 20 15.20 700 213 4.47 / 82.20 5 100
7 8 -0.04 259 15.21 344 1355 5.82 / 83.56 5 130
Average= 5.22
(KJ/cycle)

Cycle 14 GMT 2/ 8/2019 21:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 30 15.20 521 238 0.24 / 72.07 5 28
2 7 2009.48 41 14.74 3299 1994 2.23 / 74.07 28 77
3 13 1811.52 20 14.78 3030 896 3.13 / 74.96 5 85
4 13 1476.24 20 14.82 2556 758 3.88 / 75.72 5 94
5 13 782.64 20 15.01 1567 470 4.35 / 76.19 5 103
6 13 102.60 20 15.25 524 160 4.51 / 76.35 5 92
7 8 -0.04 261 15.22 348 1382 5.90 / 77.73 5 134
Average= 5.18
(KJ/cycle)

Cycle 13 GMT 24/ 7/2019 0:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 30 15.22 520 237 0.24 / 66.27 5 26
2 7 2014.60 40 14.74 3297 1944 2.18 / 68.22 26 77
3 13 1919.76 20 14.76 3180 939 3.12 / 69.15 5 83
4 13 1352.96 20 14.85 2391 710 3.83 / 69.86 5 97
5 13 589.68 20 15.08 1298 391 4.22 / 70.26 5 104
6 13 156.64 20 15.23 625 190 4.41 / 70.45 5 95
7 13 33.80 20 15.27 410 125 4.54 / 70.57 5 87
8 8 0.00 238 15.22 349 1264 5.80 / 71.84 5 131
Average= 5.13
(KJ/cycle)

Cycle 12 GMT 14/ 7/2019 3: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 30 15.21 514 235 0.23 / 60.58 5 26
2 7 2012.04 40 14.75 3309 1952 2.19 / 62.53 26 76
3 13 1814.60 20 14.79 3039 899 3.09 / 63.43 5 85
4 13 1195.20 20 14.90 2172 647 3.73 / 64.08 5 99
5 13 656.36 20 15.06 1382 416 4.15 / 64.50 5 102
6 13 108.72 20 15.25 543 166 4.31 / 64.66 5 91
7 8 0.08 259 15.23 348 1373 5.69 / 66.03 5 132
Average= 5.08
(KJ/cycle)

Cycle 11 GMT 4/ 7/2019 5:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 30 15.22 537 245 0.25 / 54.74 5 25
2 7 2007.44 41 14.75 3292 1991 2.24 / 56.73 25 77
3 13 1922.44 20 14.77 3196 944 3.18 / 57.68 5 83
4 13 1292.04 20 14.88 2312 688 3.87 / 58.36 5 97
5 13 651.60 20 15.06 1380 416 4.28 / 58.78 5 103
6 13 103.92 20 15.26 527 161 4.44 / 58.94 5 91
7 8 -0.04 264 15.23 350 1407 5.85 / 60.35 5 130
Average= 5.03
(KJ/cycle)

Cycle 10 GMT 24/ 6/2019 7:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 30 15.22 527 241 0.24 / 48.94 5 26
2 7 2007.84 40 14.76 3290 1942 2.18 / 50.89 26 77
3 13 1909.00 20 14.78 3170 937 3.12 / 51.82 5 83
4 13 1470.44 20 14.83 2573 763 3.88 / 52.59 5 95
5 13 590.84 20 15.09 1298 392 4.27 / 52.98 5 103
6 13 82.16 20 15.27 492 150 4.43 / 53.13 5 90
7 8 0.04 255 15.23 352 1367 5.79 / 54.49 5 133
Average= 4.95
(KJ/cycle)

Cycle 9 GMT 14/ 6/2019 10:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 30 15.22 518 237 0.24 / 43.20 5 24
2 7 2011.28 40 14.77 3301 1950 2.19 / 45.15 24 77
3 13 1822.04 20 14.80 3027 896 3.08 / 46.04 5 85
4 13 1093.16 20 14.95 2019 604 3.69 / 46.65 5 101
5 13 779.04 20 15.01 1573 472 4.16 / 47.12 5 104
6 13 202.12 20 15.22 694 211 4.37 / 47.33 5 100
7 8 0.04 259 15.23 348 1373 5.74 / 48.70 5 133
Average= 4.87
(KJ/cycle)

Cycle 8 GMT 4/ 6/2019 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 29 15.22 531 234 0.23 / 37.46 5 22
2 3 1023.64 1 15.27 1939 30 0.26 / 37.49 5 26
3 7 2007.52 40 14.77 3277 1936 2.20 / 39.42 26 76
4 13 1810.56 20 14.80 3036 899 3.10 / 40.32 5 85
5 13 1201.64 20 14.91 2176 649 3.75 / 40.97 5 99
6 13 686.52 20 15.06 1429 430 4.18 / 41.40 5 103
7 13 126.96 20 15.25 565 172 4.35 / 41.57 5 94
8 8 -0.04 262 15.23 348 1389 5.74 / 42.96 5 130
Average= 4.77
(KJ/cycle)

Cycle 7 GMT 25/ 5/2019 14:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 29 15.23 519 229 0.23 / 31.69 5 23
2 7 2005.48 40 14.78 3294 1947 2.18 / 33.64 11 77
3 13 1912.16 20 14.80 3173 939 3.12 / 34.58 5 83
4 13 1186.28 20 14.92 2167 647 3.76 / 35.22 5 100
5 13 653.76 20 15.07 1376 415 4.18 / 35.64 5 104
6 13 207.52 20 15.22 708 216 4.39 / 35.85 5 102
7 8 0.04 261 15.23 344 1367 5.76 / 37.22 5 131
Average= 4.65
(KJ/cycle)

Cycle 6 GMT 15/ 5/2019 17:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 26 15.23 498 197 0.20 / 25.74 5 16
2 10 1030.52 3 15.14 1952 89 0.29 / 25.83 5 62
3 7 2012.52 40 14.79 3288 1945 2.23 / 27.78 62 77
4 13 1815.08 20 14.82 3027 897 3.13 / 28.67 5 84
5 13 1398.92 20 14.87 2451 729 3.86 / 29.40 5 95
6 13 729.16 20 15.05 1476 444 4.30 / 29.85 5 103
7 13 273.88 20 15.19 812 247 4.55 / 30.09 5 104
8 8 -0.48 259 15.23 347 1369 5.92 / 31.46 5 131
Average= 4.49
(KJ/cycle)

Cycle 5 GMT 5/ 5/2019 20: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 31 15.23 517 244 0.24 / 20.03 5 26
2 3 883.28 -2 15.58 0 0 0.00 / 20.03 5 26
3 7 2005.88 40 14.78 3296 1949 2.19 / 21.97 26 77
4 13 1809.04 20 14.82 3045 903 3.10 / 22.88 5 85
5 13 1383.52 20 14.87 2446 727 3.82 / 23.60 5 97
6 13 600.16 20 15.09 1310 395 4.22 / 24.00 5 104
7 13 158.92 20 15.24 630 192 4.41 / 24.19 5 97
8 8 -0.08 255 15.24 348 1352 5.76 / 25.54 5 131
Average= 4.26
(KJ/cycle)

Cycle 4 GMT 25/ 4/2019 22:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 28 15.23 523 223 0.22 / 15.04 5 21
2 7 1506.48 41 14.97 2569 1577 1.80 / 16.62 21 81
3 13 1424.00 20 14.98 2480 743 2.54 / 17.36 5 86
4 13 1204.80 20 14.98 2182 654 3.20 / 18.01 5 94
5 13 503.84 20 15.16 1157 351 3.55 / 18.36 5 104
6 13 35.16 20 15.31 409 125 3.67 / 18.49 5 89
7 8 -0.04 242 15.25 350 1292 4.96 / 19.78 5 131
Average= 3.96
(KJ/cycle)

Cycle 3 GMT 24/ 4/2019 12: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 26 15.24 525 208 0.21 / 10.07 5 20
2 3 1084.68 2 15.16 2007 61 0.27 / 10.13 5 73
3 7 1512.44 40 14.97 2596 1554 1.82 / 11.68 73 80
4 13 1437.92 20 14.97 2506 750 2.57 / 12.43 5 85
5 13 1129.84 20 14.99 2070 621 3.19 / 13.05 5 94
6 13 462.64 20 15.16 1097 333 3.53 / 13.38 5 103
7 13 30.92 20 15.30 411 126 3.65 / 13.51 5 88
8 8 0.04 250 15.25 343 1308 4.96 / 14.82 5 131
Average= 3.70
(KJ/cycle)

Cycle 2 GMT 23/ 4/2019 1:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 31 15.26 507 240 0.24 / 5.35 5 26
2 3 858.48 -2 15.59 0 0 0.00 / 5.35 5 26
3 7 1427.68 40 15.01 2467 1481 1.72 / 6.83 26 80
4 13 1352.88 20 15.01 2368 711 2.43 / 7.54 5 87
5 13 1034.92 20 15.03 1935 582 3.01 / 8.13 5 94
6 13 472.44 20 15.17 1103 335 3.35 / 8.46 5 101
7 13 53.84 20 15.30 441 135 3.48 / 8.60 5 93
8 8 0.08 244 15.25 339 1261 4.74 / 9.86 5 132
Average= 3.29
(KJ/cycle)

Cycle 1 GMT 21/ 4/2019 15:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 31 15.44 500 239 0.24 / 2.23 6 17
2 3 839.12 -3 15.60 0 0 0.00 / 2.23 6 17
3 7 986.52 40 15.13 1849 1119 1.36 / 3.35 17 90
4 13 451.28 20 15.24 1083 330 1.69 / 3.68 5 96
5 13 30.00 20 15.36 401 123 1.81 / 3.80 5 85
6 8 0.16 253 15.30 339 1312 3.12 / 5.11 5 144
Average= 2.56
(KJ/cycle)

Cycle 0 GMT 21/ 4/2019 4:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 30 15.61 511 239 0.24 / 0.24 6 25
2 7 121.16 40 15.59 520 324 0.56 / 0.56 25 33
3 13 71.44 20 15.58 451 141 0.70 / 0.70 6 30
4 8 0.20 267 15.52 310 1285 1.99 / 1.99 6 133
Average= 1.99
(KJ/cycle)