SIO Argo Site:
Pump Diagnostics Page   



Serial= 8541 WMO= 3901251

Return

←PreviousNext→

Cycle 298 GMT 20/ 4/2024 8:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 32 10.91 408 142 0.14 / 1437.29 2 2
2 10 1022.96 3 9.45 1776 50 0.19 / 1437.34 2 2
3 3 1062.52 2 9.46 1827 35 0.23 / 1437.38 2 2
4 3 1045.48 1 9.36 1818 17 0.24 / 1437.39 2 2
5 12 1149.00 70 8.26 1944 1124 1.37 / 1438.52 2 2
6 7 1147.64 24 8.24 1967 389 1.76 / 1438.91 2 2
7 13 1041.64 40 8.59 1798 618 2.38 / 1439.52 2 2
8 13 635.88 40 9.49 1213 460 2.84 / 1439.98 2 2
9 13 45.48 40 10.86 315 137 2.97 / 1440.12 2 2
10 8 0.00 165 10.94 252 455 3.43 / 1440.58 2 2
Average= 4.82
(KJ/cycle)

Cycle 297 GMT 10/ 4/2024 14:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 29 11.21 417 136 0.14 / 1431.74 2 2
2 10 1055.08 4 9.72 1826 71 0.21 / 1431.81 2 2
3 3 1097.80 2 9.74 1893 37 0.24 / 1431.85 2 2
4 3 1053.88 1 9.73 1818 18 0.26 / 1431.86 2 2
5 12 1149.48 5 9.51 1976 94 0.36 / 1431.96 2 2
6 12 1962.56 70 7.16 3144 1576 1.93 / 1433.53 2 2
7 7 1958.44 24 6.42 3124 481 2.41 / 1434.01 2 2
8 13 1853.64 40 7.26 2980 865 3.28 / 1434.88 2 2
9 13 1588.76 40 7.91 2597 822 4.10 / 1435.70 2 2
10 13 1035.44 40 9.02 1807 652 4.75 / 1436.35 2 2
11 13 332.92 40 10.31 773 319 5.07 / 1436.67 2 2
12 8 0.04 165 10.99 262 475 5.55 / 1437.15 2 2
Average= 4.82
(KJ/cycle)

Cycle 296 GMT 9/ 4/2024 10: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 28 11.75 430 141 0.14 / 1427.98 2 2
2 10 1000.20 4 10.49 1775 74 0.22 / 1428.05 2 2
3 3 1089.84 2 10.35 1883 39 0.25 / 1428.09 2 2
4 3 1046.20 1 10.39 1834 19 0.27 / 1428.11 2 2
5 12 1158.20 70 7.81 1958 1070 1.34 / 1429.18 2 2
6 7 1156.60 24 8.34 1978 396 1.74 / 1429.58 2 2
7 13 1048.68 40 8.69 1822 633 2.37 / 1430.21 2 2
8 13 920.04 40 9.15 1635 598 2.97 / 1430.81 2 2
9 13 287.20 40 10.62 706 300 3.27 / 1431.11 2 2
10 8 0.12 165 11.27 266 495 3.77 / 1431.60 2 2
Average= 4.82
(KJ/cycle)

Cycle 295 GMT 30/ 3/2024 16: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 30 12.43 443 165 0.17 / 1424.50 2 2
2 10 1008.32 3 11.74 1807 64 0.23 / 1424.57 2 2
3 12 1116.80 70 7.92 1883 1044 1.27 / 1425.61 2 2
4 7 1115.52 24 9.04 1928 418 1.69 / 1426.03 2 2
5 13 1009.24 40 9.13 1767 645 2.34 / 1426.67 2 2
6 13 622.56 40 10.29 1208 497 2.83 / 1427.17 2 2
7 13 34.36 40 11.78 311 147 2.98 / 1427.32 2 2
8 8 0.12 165 11.69 269 519 3.50 / 1427.84 2 2
Average= 4.82
(KJ/cycle)

Cycle 294 GMT 20/ 3/2024 22: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 28 13.22 434 161 0.16 / 1420.91 2 2
2 10 1040.80 3 12.28 1854 68 0.23 / 1420.97 2 2
3 12 1121.48 70 8.08 1902 1076 1.30 / 1422.05 2 2
4 7 1120.56 24 9.80 1928 453 1.76 / 1422.50 2 2
5 13 1013.72 40 9.72 1769 688 2.45 / 1423.19 2 2
6 13 457.68 40 11.32 978 443 2.89 / 1423.63 2 2
7 13 24.92 40 12.47 299 149 3.04 / 1423.78 2 2
8 8 0.00 165 12.30 273 554 3.59 / 1424.34 2 2
Average= 4.83
(KJ/cycle)

Cycle 293 GMT 11/ 3/2024 4: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 28 13.50 432 163 0.16 / 1416.01 2 2
2 3 1052.04 1 11.84 1860 22 0.19 / 1416.04 2 2
3 3 1024.28 1 11.52 1825 21 0.21 / 1416.06 2 2
4 12 1129.80 5 11.65 1974 115 0.32 / 1416.17 2 2
5 12 1933.28 70 9.17 3100 1990 2.31 / 1418.16 2 2
6 7 1927.68 24 9.57 3110 714 3.03 / 1418.88 2 2
7 13 1096.16 40 10.97 1921 843 3.87 / 1419.72 2 2
8 13 368.84 40 12.24 863 423 4.29 / 1420.14 2 2
9 8 0.08 165 12.96 282 603 4.89 / 1420.75 2 2
Average= 4.83
(KJ/cycle)

Cycle 292 GMT 9/ 3/2024 23:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 28 14.04 433 170 0.17 / 1412.11 2 2
2 12 1151.00 70 6.00 1898 797 0.97 / 1412.91 2 2
3 7 1154.32 24 9.78 2000 469 1.44 / 1413.38 2 2
4 13 1143.40 40 9.27 1968 730 2.17 / 1414.11 2 2
5 13 1027.36 40 9.95 1810 720 2.89 / 1414.83 2 2
6 13 342.68 40 12.37 829 410 3.30 / 1415.24 2 2
7 8 0.04 165 13.31 279 613 3.91 / 1415.85 2 2
Average= 4.83
(KJ/cycle)

Cycle 291 GMT 29/ 2/2024 5:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 28 14.16 439 174 0.17 / 1408.22 2 2
2 12 1143.00 70 6.31 1894 837 1.01 / 1409.06 2 2
3 7 1146.08 24 9.82 1978 466 1.48 / 1409.52 2 2
4 13 1093.24 40 9.64 1881 725 2.20 / 1410.25 2 2
5 13 975.80 40 10.32 1729 714 2.92 / 1410.96 2 2
6 13 228.96 40 13.34 637 340 3.26 / 1411.30 2 2
7 8 0.04 165 13.86 279 638 3.89 / 1411.94 2 2
Average= 4.84
(KJ/cycle)

Cycle 290 GMT 19/ 2/2024 11: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 28 14.27 444 177 0.18 / 1404.63 2 2
2 12 1126.16 70 8.32 1903 1108 1.29 / 1405.74 2 2
3 7 1124.20 24 10.19 1943 475 1.76 / 1406.21 2 2
4 13 1001.64 40 10.58 1766 747 2.51 / 1406.96 2 2
5 13 299.12 40 13.43 762 409 2.92 / 1407.37 2 2
6 8 0.00 165 14.05 292 677 3.59 / 1408.05 2 2
Average= 4.84
(KJ/cycle)

Cycle 289 GMT 9/ 2/2024 16:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 28 14.27 441 176 0.18 / 1399.27 2 2
2 12 1122.40 5 11.51 1974 114 0.29 / 1399.38 2 2
3 12 1939.96 70 9.39 3136 2061 2.35 / 1401.44 2 2
4 7 1934.56 24 10.05 3139 757 3.11 / 1402.20 2 2
5 13 1320.92 40 11.77 2275 1071 4.18 / 1403.27 2 2
6 13 362.00 40 13.48 881 475 4.65 / 1403.74 2 2
7 8 0.04 165 14.14 304 709 5.36 / 1404.45 2 2
Average= 4.84
(KJ/cycle)

Cycle 288 GMT 8/ 2/2024 13: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 28 14.22 453 180 0.18 / 1394.79 2 2
2 12 1140.80 70 5.65 1942 768 0.95 / 1395.55 2 2
3 7 1145.56 24 10.03 1950 469 1.42 / 1396.02 2 2
4 13 1218.16 40 9.82 2094 823 2.24 / 1396.85 2 2
5 13 1142.44 40 10.61 1988 844 3.08 / 1397.69 2 2
6 13 733.24 40 12.46 1423 709 3.79 / 1398.40 2 2
7 8 0.08 165 14.20 295 691 4.48 / 1399.09 2 2
Average= 4.84
(KJ/cycle)

Cycle 287 GMT 29/ 1/2024 18:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 28 14.26 453 181 0.18 / 1391.09 2 2
2 12 1137.24 70 6.82 1892 903 1.08 / 1391.99 2 2
3 7 1138.68 24 10.00 1990 478 1.56 / 1392.47 2 2
4 13 1056.40 40 10.66 1858 792 2.35 / 1393.26 2 2
5 13 656.92 40 12.63 1313 663 3.02 / 1393.93 2 2
6 8 0.08 165 14.22 289 678 3.70 / 1394.60 2 2
Average= 4.84
(KJ/cycle)

Cycle 286 GMT 20/ 1/2024 0:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 27 14.30 447 173 0.17 / 1387.38 2 2
2 12 1142.00 70 8.39 1932 1135 1.31 / 1388.51 2 2
3 7 1140.08 24 10.39 1987 495 1.80 / 1389.01 2 2
4 13 1007.48 40 11.47 1798 825 2.63 / 1389.83 2 2
5 13 271.44 40 13.66 720 393 3.02 / 1390.23 2 2
6 8 0.04 165 14.26 290 682 3.70 / 1390.91 2 2
Average= 4.85
(KJ/cycle)

Cycle 285 GMT 10/ 1/2024 6:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 28 14.29 433 173 0.17 / 1382.12 2 2
2 12 1110.96 5 11.48 1935 111 0.28 / 1382.23 2 2
3 12 1931.60 70 9.38 3130 2055 2.34 / 1384.29 2 2
4 7 1925.44 24 10.16 3112 759 3.10 / 1385.05 2 2
5 13 1326.24 40 12.06 2277 1098 4.20 / 1386.14 2 2
6 13 234.96 40 13.84 670 371 4.57 / 1386.51 2 2
7 8 0.12 165 14.30 293 691 5.26 / 1387.21 2 2
Average= 4.85
(KJ/cycle)

Cycle 284 GMT 9/ 1/2024 2:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 28 14.25 446 178 0.18 / 1378.10 2 2
2 12 1135.24 70 6.29 1886 830 1.01 / 1378.93 2 2
3 7 1137.92 24 10.09 1966 476 1.48 / 1379.41 2 2
4 13 1082.92 40 10.99 1884 828 2.31 / 1380.23 2 2
5 13 956.72 40 11.70 1717 804 3.12 / 1381.04 2 2
6 13 75.84 40 14.09 398 224 3.34 / 1381.26 2 2
7 8 0.04 165 14.27 291 685 4.03 / 1381.95 2 2
Average= 4.85
(KJ/cycle)

Cycle 283 GMT 30/12/2023 8: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 28 14.29 447 179 0.18 / 1374.43 2 2
2 12 1116.88 70 7.21 1872 945 1.12 / 1375.38 2 2
3 7 1117.64 24 10.23 1952 479 1.60 / 1375.86 2 2
4 13 1039.72 40 11.31 1838 832 2.43 / 1376.69 2 2
5 13 471.36 40 13.17 1038 547 2.98 / 1377.24 2 2
6 8 0.12 165 14.25 291 684 3.67 / 1377.92 2 2
Average= 4.85
(KJ/cycle)

Cycle 282 GMT 20/12/2023 13:55:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 28 14.29 449 180 0.18 / 1370.67 2 2
2 12 1133.16 70 8.66 1917 1162 1.34 / 1371.83 2 2
3 7 1131.52 24 10.58 1962 498 1.84 / 1372.33 2 2
4 13 1003.44 40 11.96 1788 855 2.70 / 1373.19 2 2
5 13 249.92 40 13.75 686 377 3.07 / 1373.57 2 2
6 8 0.00 165 14.29 293 691 3.76 / 1374.26 2 2
Average= 4.86
(KJ/cycle)

Cycle 281 GMT 10/12/2023 19:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 28 14.23 449 179 0.18 / 1365.45 2 2
2 12 1103.72 5 11.43 1916 109 0.29 / 1365.56 2 2
3 12 1935.20 70 9.51 3119 2076 2.36 / 1367.63 2 2
4 7 1929.52 24 10.29 3137 775 3.14 / 1368.41 2 2
5 13 1081.00 40 12.63 1908 964 4.10 / 1369.37 2 2
6 13 300.56 40 13.78 768 423 4.53 / 1369.80 2 2
7 8 0.08 165 14.30 295 696 5.22 / 1370.49 2 2
Average= 4.86
(KJ/cycle)

Cycle 280 GMT 9/12/2023 15:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 28 14.21 449 179 0.18 / 1361.03 2 2
2 12 1133.76 70 5.66 1948 772 0.95 / 1361.80 2 2
3 7 1138.36 24 10.23 1948 478 1.43 / 1362.28 2 2
4 13 1219.04 40 10.87 2100 913 2.34 / 1363.19 2 2
5 13 1120.96 40 11.42 1959 895 3.24 / 1364.09 2 2
6 13 417.08 40 13.38 950 508 3.75 / 1364.60 2 2
7 8 0.08 165 14.28 286 674 4.42 / 1365.27 2 2
Average= 4.86
(KJ/cycle)

Cycle 279 GMT 29/11/2023 21:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 28 14.26 448 179 0.18 / 1357.33 2 2
2 12 1129.00 70 6.44 1876 846 1.02 / 1358.18 2 2
3 7 1131.00 24 10.24 1957 481 1.51 / 1358.66 2 2
4 13 1062.76 40 11.40 1871 853 2.36 / 1359.51 2 2
5 13 656.68 40 12.81 1291 662 3.02 / 1360.17 2 2
6 8 0.04 165 14.28 288 679 3.70 / 1360.85 2 2
Average= 4.86
(KJ/cycle)

Cycle 278 GMT 20/11/2023 3: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 28 14.30 430 172 0.17 / 1353.59 2 2
2 12 1126.44 70 8.17 1899 1086 1.26 / 1354.67 2 2
3 7 1125.04 24 10.62 1986 506 1.76 / 1355.18 2 2
4 13 1005.76 40 12.04 1808 871 2.64 / 1356.05 2 2
5 13 288.88 40 13.70 742 407 3.04 / 1356.46 2 2
6 8 0.08 165 14.29 295 696 3.74 / 1357.15 2 2
Average= 4.86
(KJ/cycle)

Cycle 277 GMT 10/11/2023 9: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 28 14.21 447 178 0.18 / 1348.45 2 2
2 12 1112.04 5 11.39 1934 110 0.29 / 1348.56 2 2
3 12 1936.80 70 9.28 3123 2029 2.32 / 1350.59 2 2
4 7 1930.96 24 10.27 3113 767 3.08 / 1351.36 2 2
5 13 1062.00 40 12.72 1881 957 4.04 / 1352.32 2 2
6 13 282.76 40 13.84 739 409 4.45 / 1352.73 2 2
7 8 0.04 165 14.32 291 688 5.14 / 1353.41 2 2
Average= 4.87
(KJ/cycle)

Cycle 276 GMT 9/11/2023 5: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 28 14.24 419 167 0.17 / 1344.71 2 2
2 12 1134.72 70 6.25 1872 819 0.99 / 1345.53 2 2
3 7 1137.00 24 10.30 1960 485 1.47 / 1346.01 2 2
4 13 1077.92 40 11.49 1878 863 2.33 / 1346.88 2 2
5 13 674.32 40 12.77 1366 698 3.03 / 1347.58 2 2
6 8 0.08 165 14.26 298 701 3.73 / 1348.28 2 2
Average= 4.87
(KJ/cycle)

Cycle 275 GMT 30/10/2023 10:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 28 14.26 435 174 0.17 / 1340.88 2 2
2 12 1123.56 70 6.34 1852 822 1.00 / 1341.71 2 2
3 7 1126.52 24 10.34 1955 485 1.48 / 1342.19 2 2
4 13 1074.08 40 11.57 1883 871 2.35 / 1343.06 2 2
5 13 946.76 40 12.06 1702 821 3.17 / 1343.88 2 2
6 8 0.08 165 14.29 280 660 3.83 / 1344.54 2 2
Average= 4.87
(KJ/cycle)

Cycle 274 GMT 20/10/2023 16:43:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 28 14.25 441 176 0.18 / 1337.21 2 2
2 12 1122.36 70 8.35 1886 1102 1.28 / 1338.32 2 2
3 7 1120.76 24 10.80 1946 504 1.78 / 1338.82 2 2
4 13 1005.36 40 12.21 1791 875 2.66 / 1339.69 2 2
5 13 230.88 40 13.86 645 358 3.02 / 1340.05 2 2
6 8 0.04 165 14.30 279 658 3.67 / 1340.71 2 2
Average= 4.88
(KJ/cycle)

Cycle 273 GMT 10/10/2023 22:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 28 14.19 448 178 0.18 / 1331.99 2 2
2 12 1104.72 5 11.37 1918 109 0.29 / 1332.10 2 2
3 12 1938.24 70 9.29 3120 2029 2.32 / 1334.13 2 2
4 7 1932.96 24 10.34 3130 777 3.09 / 1334.90 2 2
5 13 1209.80 40 12.57 2094 1053 4.15 / 1335.96 2 2
6 13 272.88 40 13.85 722 400 4.55 / 1336.36 2 2
7 8 0.04 165 14.31 289 682 5.23 / 1337.04 2 2
Average= 4.88
(KJ/cycle)

Cycle 272 GMT 9/10/2023 18:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 28 14.21 444 177 0.18 / 1328.13 2 2
2 12 1132.48 70 6.18 1861 805 0.98 / 1328.93 2 2
3 7 1135.40 24 10.44 1963 492 1.47 / 1329.42 2 2
4 13 1080.92 40 11.67 1897 886 2.36 / 1330.31 2 2
5 13 954.08 40 12.11 1716 831 3.19 / 1331.14 2 2
6 8 0.16 165 14.27 284 669 3.86 / 1331.81 2 2
Average= 4.88
(KJ/cycle)

Cycle 271 GMT 30/ 9/2023 0:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 28 14.20 448 178 0.18 / 1323.64 2 2
2 12 1129.24 70 5.61 1858 730 0.91 / 1324.37 2 2
3 7 1134.16 24 10.41 1942 485 1.39 / 1324.85 2 2
4 13 1211.56 40 11.23 2079 934 2.33 / 1325.79 2 2
5 13 1112.44 40 11.67 1942 907 3.23 / 1326.69 2 2
6 13 518.64 40 13.31 1091 581 3.81 / 1327.27 2 2
7 8 0.24 165 14.27 287 676 4.49 / 1327.95 2 2
Average= 4.88
(KJ/cycle)

Cycle 270 GMT 20/ 9/2023 6:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 28 14.21 442 176 0.18 / 1319.96 2 2
2 12 1126.20 70 7.70 1880 1013 1.19 / 1320.98 2 2
3 7 1125.76 24 10.79 1948 504 1.69 / 1321.48 2 2
4 13 1029.16 40 12.19 1823 889 2.58 / 1322.37 2 2
5 13 311.48 40 13.69 783 429 3.01 / 1322.80 2 2
6 8 0.08 165 14.28 281 662 3.67 / 1323.46 2 2
Average= 4.88
(KJ/cycle)

Cycle 269 GMT 10/ 9/2023 12: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 28 14.17 450 179 0.18 / 1314.62 2 2
2 12 1124.44 5 11.34 1943 110 0.29 / 1314.73 2 2
3 12 1939.28 70 9.12 3116 1989 2.28 / 1316.72 2 2
4 7 1933.92 24 10.44 3134 785 3.06 / 1317.51 2 2
5 13 1329.96 40 12.47 2252 1123 4.19 / 1318.63 2 2
6 13 354.28 40 13.73 858 471 4.66 / 1319.10 2 2
7 8 0.04 165 14.28 291 686 5.34 / 1319.79 2 2
Average= 4.89
(KJ/cycle)

Cycle 268 GMT 9/ 9/2023 8:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 28 14.20 438 174 0.17 / 1310.85 2 2
2 12 1133.36 70 6.31 1854 819 0.99 / 1311.67 2 2
3 7 1135.48 24 10.55 1971 499 1.49 / 1312.17 2 2
4 13 1056.28 40 11.94 1863 890 2.38 / 1313.06 2 2
5 13 676.00 40 13.03 1332 694 3.08 / 1313.75 2 2
6 8 0.08 165 14.26 293 689 3.77 / 1314.44 2 2
Average= 4.89
(KJ/cycle)

Cycle 267 GMT 30/ 8/2023 14:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 28 14.19 444 176 0.18 / 1306.41 2 2
2 12 1137.16 70 5.60 1854 727 0.90 / 1307.14 2 2
3 7 1141.68 24 10.54 1957 495 1.40 / 1307.63 2 2
4 13 1209.80 40 11.46 2088 957 2.36 / 1308.59 2 2
5 13 1107.12 40 11.86 1945 923 3.28 / 1309.51 2 2
6 13 357.84 40 13.63 864 471 3.75 / 1309.98 2 2
7 8 0.04 165 14.26 296 696 4.45 / 1310.68 2 2
Average= 4.89
(KJ/cycle)

Cycle 266 GMT 20/ 8/2023 19:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 28 14.22 435 173 0.17 / 1302.73 2 2
2 12 1128.68 70 7.85 1885 1036 1.21 / 1303.76 2 2
3 7 1128.48 24 10.89 1959 512 1.72 / 1304.27 2 2
4 13 1011.48 40 12.33 1797 886 2.61 / 1305.16 2 2
5 13 269.76 40 13.80 720 397 3.00 / 1305.56 2 2
6 8 0.12 165 14.27 287 676 3.68 / 1306.23 2 2
Average= 4.89
(KJ/cycle)

Cycle 265 GMT 11/ 8/2023 1:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 28 14.17 440 175 0.17 / 1297.40 2 2
2 12 1111.20 5 11.39 1948 111 0.29 / 1297.51 2 2
3 12 1935.72 70 9.24 3118 2017 2.30 / 1299.52 2 2
4 7 1929.84 24 10.48 3113 783 3.09 / 1300.31 2 2
5 13 1344.28 40 12.47 2279 1137 4.22 / 1301.44 2 2
6 13 280.52 40 13.84 742 411 4.63 / 1301.86 2 2
7 8 0.04 165 14.27 296 697 5.33 / 1302.55 2 2
Average= 4.90
(KJ/cycle)

Cycle 264 GMT 9/ 8/2023 21:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 28 14.18 435 173 0.17 / 1293.43 2 2
2 12 1125.04 70 6.22 1834 799 0.97 / 1294.23 2 2
3 7 1127.80 24 10.67 1965 503 1.47 / 1294.74 2 2
4 13 1079.44 40 12.00 1912 918 2.39 / 1295.65 2 2
5 13 952.28 40 12.39 1720 852 3.24 / 1296.51 2 2
6 8 0.08 165 14.25 305 717 3.96 / 1297.22 2 2
Average= 4.90
(KJ/cycle)

Cycle 263 GMT 31/ 7/2023 3:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 28 14.15 438 174 0.17 / 1289.04 2 2
2 12 1127.56 70 5.64 1842 727 0.90 / 1289.77 2 2
3 7 1131.68 24 10.66 1942 497 1.40 / 1290.27 2 2
4 13 1192.32 40 11.66 2058 960 2.36 / 1291.23 2 2
5 13 1081.88 40 12.06 1907 920 3.28 / 1292.15 2 2
6 13 332.56 40 13.69 816 447 3.72 / 1292.59 2 2
7 8 0.04 165 14.26 284 668 4.39 / 1293.26 2 2
Average= 4.90
(KJ/cycle)

Cycle 262 GMT 21/ 7/2023 9: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 28 14.18 442 175 0.18 / 1285.36 2 2
2 12 1115.24 70 7.98 1872 1046 1.22 / 1286.40 2 2
3 7 1115.20 24 10.92 1951 511 1.73 / 1286.91 2 2
4 13 1017.72 40 12.34 1804 890 2.62 / 1287.80 2 2
5 13 276.12 40 13.79 724 399 3.02 / 1288.20 2 2
6 8 -0.08 165 14.26 283 666 3.69 / 1288.87 2 2
Average= 4.90
(KJ/cycle)

Cycle 261 GMT 11/ 7/2023 15: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.28 28 14.15 454 180 0.18 / 1280.23 2 2
2 12 1125.68 5 11.29 1952 110 0.29 / 1280.34 2 2
3 12 1939.88 70 9.23 3129 2022 2.31 / 1282.36 2 2
4 7 1934.36 24 10.52 3137 792 3.10 / 1283.15 2 2
5 13 1086.28 40 12.79 1921 983 4.09 / 1284.14 2 2
6 13 194.00 40 13.95 615 343 4.43 / 1284.48 2 2
7 8 -0.04 165 14.27 297 699 5.13 / 1285.18 2 2
Average= 4.91
(KJ/cycle)

Cycle 260 GMT 10/ 7/2023 10:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 28 14.18 441 175 0.18 / 1276.26 2 2
2 12 1122.84 70 6.07 1829 777 0.95 / 1277.04 2 2
3 7 1126.32 24 10.72 1957 503 1.46 / 1277.55 2 2
4 13 1108.32 40 12.04 1951 940 2.40 / 1278.48 2 2
5 13 987.36 40 12.41 1776 882 3.28 / 1279.37 2 2
6 8 0.12 165 14.26 291 685 3.96 / 1280.05 2 2
Average= 4.90
(KJ/cycle)

Cycle 259 GMT 30/ 6/2023 16:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 28 14.14 462 183 0.18 / 1272.00 2 2
2 12 1137.08 70 5.97 1824 762 0.95 / 1272.76 2 2
3 7 1141.00 24 10.68 1991 510 1.46 / 1273.27 2 2
4 13 1158.92 40 11.89 2030 965 2.42 / 1274.24 2 2
5 13 1034.08 40 12.29 1849 909 3.33 / 1275.15 2 2
6 13 109.84 40 14.06 462 260 3.59 / 1275.41 2 2
7 8 0.16 165 14.25 291 684 4.27 / 1276.09 2 2
Average= 4.91
(KJ/cycle)

Cycle 258 GMT 20/ 6/2023 22:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 28 14.16 451 179 0.18 / 1268.23 2 2
2 12 1127.40 70 8.07 1880 1062 1.24 / 1269.29 2 2
3 7 1126.56 24 10.97 1965 517 1.76 / 1269.81 2 2
4 13 1015.88 40 12.42 1830 909 2.67 / 1270.72 2 2
5 13 253.84 40 13.83 700 387 3.05 / 1271.11 2 2
6 8 0.04 165 14.24 302 710 3.76 / 1271.82 2 2
Average= 4.91
(KJ/cycle)

Cycle 257 GMT 11/ 6/2023 4:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 28 14.15 450 178 0.18 / 1262.85 2 2
2 12 1117.12 5 11.31 1930 109 0.29 / 1262.96 2 2
3 12 1945.00 70 9.40 3123 2055 2.34 / 1265.01 2 2
4 7 1939.48 24 10.58 3138 797 3.14 / 1265.81 2 2
5 13 1342.96 40 12.53 2280 1143 4.28 / 1266.95 2 2
6 13 248.64 40 13.88 691 384 4.67 / 1267.34 2 2
7 8 0.00 165 14.24 304 714 5.38 / 1268.05 2 2
Average= 4.91
(KJ/cycle)

Cycle 256 GMT 10/ 6/2023 0:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 28 14.15 432 171 0.17 / 1258.37 2 2
2 12 1145.68 70 5.65 1901 752 0.92 / 1259.12 2 2
3 7 1149.84 24 10.84 1977 514 1.44 / 1259.64 2 2
4 13 1207.20 40 11.99 2105 1010 2.45 / 1260.65 2 2
5 13 1099.84 40 12.34 1941 958 3.40 / 1261.60 2 2
6 13 227.92 40 13.86 657 364 3.77 / 1261.97 2 2
7 8 0.00 165 14.24 299 703 4.47 / 1262.67 2 2
Average= 4.91
(KJ/cycle)

Cycle 255 GMT 31/ 5/2023 5:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 28 14.15 429 170 0.17 / 1253.85 2 2
2 12 1139.40 70 5.61 1822 715 0.89 / 1254.56 2 2
3 7 1143.88 24 10.79 1963 508 1.39 / 1255.07 2 2
4 13 1211.76 40 11.87 2098 996 2.39 / 1256.07 2 2
5 13 1113.32 40 12.22 1962 959 3.35 / 1257.03 2 2
6 13 339.40 40 13.66 847 463 3.81 / 1257.49 2 2
7 8 0.00 165 14.21 303 710 4.52 / 1258.20 2 2
Average= 4.91
(KJ/cycle)

Cycle 254 GMT 21/ 5/2023 11:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 28 14.16 443 176 0.18 / 1250.13 2 2
2 12 1128.36 70 7.89 1886 1042 1.22 / 1251.17 2 2
3 7 1127.76 24 10.96 1954 514 1.73 / 1251.68 2 2
4 13 1019.68 40 12.40 1820 903 2.63 / 1252.59 2 2
5 13 275.80 40 13.76 734 404 3.04 / 1252.99 2 2
6 8 0.08 165 14.23 293 688 3.73 / 1253.68 2 2
Average= 4.92
(KJ/cycle)

Cycle 253 GMT 11/ 5/2023 17:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 28 14.15 442 175 0.18 / 1244.98 2 2
2 12 1118.28 5 11.29 1938 109 0.28 / 1245.09 2 2
3 12 1935.40 70 9.33 3116 2035 2.32 / 1247.13 2 2
4 7 1929.68 24 10.62 3130 798 3.12 / 1247.92 2 2
5 13 1202.08 40 12.67 2081 1055 4.17 / 1248.98 2 2
6 13 158.92 40 14.00 537 301 4.47 / 1249.28 2 2
7 8 0.04 165 14.26 286 673 5.15 / 1249.95 2 2
Average= 4.92
(KJ/cycle)

Cycle 252 GMT 10/ 5/2023 13:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 28 14.14 435 172 0.17 / 1240.46 2 2
2 12 1126.40 70 5.63 1851 729 0.90 / 1241.19 2 2
3 7 1131.04 24 10.88 1942 507 1.41 / 1241.69 2 2
4 13 1209.24 40 12.01 2092 1005 2.41 / 1242.70 2 2
5 13 1094.00 40 12.37 1924 952 3.37 / 1243.65 2 2
6 13 352.84 40 13.64 854 466 3.83 / 1244.12 2 2
7 8 -0.12 165 14.21 294 689 4.52 / 1244.81 2 2
Average= 4.92
(KJ/cycle)

Cycle 251 GMT 30/ 4/2023 18:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 28 14.14 442 175 0.17 / 1236.05 2 2
2 12 1121.60 70 5.60 1788 701 0.88 / 1236.75 2 2
3 7 1126.36 24 10.83 1943 505 1.38 / 1237.26 2 2
4 13 1187.04 40 11.89 2061 980 2.36 / 1238.24 2 2
5 13 1076.00 40 12.29 1907 937 3.30 / 1239.18 2 2
6 13 300.40 40 13.71 775 425 3.72 / 1239.60 2 2
7 8 0.16 165 14.21 292 685 4.41 / 1240.28 2 2
Average= 4.92
(KJ/cycle)

Cycle 250 GMT 21/ 4/2023 0:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 28 14.18 435 173 0.17 / 1232.34 2 2
2 12 1134.56 70 7.65 1879 1006 1.18 / 1233.35 2 2
3 7 1134.88 24 10.93 1973 518 1.70 / 1233.87 2 2
4 13 1024.56 40 12.38 1841 912 2.61 / 1234.78 2 2
5 13 305.44 40 13.73 773 425 3.03 / 1235.20 2 2
6 8 0.00 165 14.22 287 673 3.71 / 1235.88 2 2
Average= 4.92
(KJ/cycle)

Cycle 249 GMT 11/ 4/2023 6:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 28 14.15 426 169 0.17 / 1227.33 2 2
2 12 1113.24 5 11.21 1936 109 0.28 / 1227.43 2 2
3 12 1936.36 70 9.19 3099 1994 2.27 / 1229.43 2 2
4 7 1930.72 24 10.58 3082 783 3.05 / 1230.21 2 2
5 13 1070.48 40 12.83 1895 973 4.03 / 1231.18 2 2
6 13 171.84 40 13.98 555 310 4.34 / 1231.49 2 2
7 8 0.04 165 14.26 288 678 5.01 / 1232.17 2 2
Average= 4.93
(KJ/cycle)

Cycle 248 GMT 10/ 4/2023 2:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 28 14.12 441 174 0.17 / 1222.84 2 2
2 12 1136.12 70 5.61 1852 727 0.90 / 1223.57 2 2
3 7 1141.32 24 10.91 1966 515 1.42 / 1224.08 2 2
4 13 1216.32 40 12.02 2113 1016 2.43 / 1225.10 2 2
5 13 1093.40 40 12.39 1936 959 3.39 / 1226.06 2 2
6 13 315.88 40 13.69 792 434 3.83 / 1226.49 2 2
7 8 0.04 165 14.22 284 666 4.49 / 1227.16 2 2
Average= 4.93
(KJ/cycle)

Cycle 247 GMT 31/ 3/2023 7:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 28 14.13 443 175 0.18 / 1218.43 2 2
2 12 1134.68 70 5.58 1729 675 0.85 / 1219.10 2 2
3 7 1139.68 24 10.74 1969 508 1.36 / 1219.61 2 2
4 13 1209.04 40 11.78 2086 983 2.34 / 1220.59 2 2
5 13 1103.48 40 12.22 1932 944 3.29 / 1221.54 2 2
6 13 342.76 40 13.64 834 455 3.74 / 1221.99 2 2
7 8 0.00 165 14.21 287 673 4.41 / 1222.66 2 2
Average= 4.93
(KJ/cycle)

Cycle 246 GMT 21/ 3/2023 13:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 28 14.17 443 176 0.18 / 1214.64 2 2
2 12 1128.76 70 7.39 1865 965 1.14 / 1215.60 2 2
3 7 1130.16 24 10.92 1967 516 1.66 / 1216.12 2 2
4 13 1038.04 40 12.35 1852 915 2.57 / 1217.03 2 2
5 13 447.80 40 13.47 1006 542 3.11 / 1217.57 2 2
6 8 0.00 165 14.21 289 678 3.79 / 1218.25 2 2
Average= 4.93
(KJ/cycle)

Cycle 245 GMT 11/ 3/2023 19:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.28 28 14.11 470 186 0.19 / 1209.40 2 2
2 12 1113.44 5 11.14 1942 108 0.29 / 1209.50 2 2
3 12 1934.76 70 9.16 3116 1998 2.29 / 1211.50 2 2
4 7 1928.96 24 10.61 3100 789 3.08 / 1212.29 2 2
5 13 1203.04 40 12.67 2072 1050 4.13 / 1213.34 2 2
6 13 266.68 40 13.80 732 404 4.54 / 1213.75 2 2
7 8 0.12 165 14.22 305 716 5.25 / 1214.46 2 2
Average= 4.94
(KJ/cycle)

Cycle 244 GMT 10/ 3/2023 15:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 28 14.12 446 176 0.18 / 1205.10 2 2
2 12 1127.08 70 5.85 1847 756 0.93 / 1205.86 2 2
3 7 1131.60 24 10.93 1953 512 1.44 / 1206.37 2 2
4 13 1172.92 40 12.14 2043 992 2.44 / 1207.36 2 2
5 13 1048.08 40 12.51 1868 935 3.37 / 1208.30 2 2
6 13 73.32 40 14.08 408 230 3.60 / 1208.53 2 2
7 8 0.00 165 14.22 290 680 4.28 / 1209.21 2 2
Average= 4.94
(KJ/cycle)

Cycle 243 GMT 28/ 2/2023 21: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 28 14.12 441 174 0.17 / 1200.76 2 2
2 12 1138.64 70 5.59 1752 686 0.86 / 1201.45 2 2
3 7 1142.84 24 10.80 1962 509 1.37 / 1201.96 2 2
4 13 1201.68 40 11.89 2091 994 2.36 / 1202.95 2 2
5 13 1098.84 40 12.31 1936 953 3.32 / 1203.90 2 2
6 13 217.04 40 13.84 635 352 3.67 / 1204.25 2 2
7 8 0.04 165 14.21 287 673 4.34 / 1204.93 2 2
Average= 4.94
(KJ/cycle)

Cycle 242 GMT 19/ 2/2023 2:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 28 14.15 451 179 0.18 / 1196.96 2 2
2 12 1134.76 70 7.33 1858 953 1.13 / 1197.91 2 2
3 7 1137.08 24 10.98 1979 522 1.65 / 1198.44 2 2
4 13 1058.68 40 12.36 1876 927 2.58 / 1199.36 2 2
5 13 464.40 40 13.47 1018 548 3.13 / 1199.91 2 2
6 8 0.00 165 14.21 288 675 3.80 / 1200.59 2 2
Average= 4.94
(KJ/cycle)

Cycle 241 GMT 9/ 2/2023 8:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 28 14.15 433 172 0.17 / 1191.61 2 2
2 12 1106.56 5 10.99 1933 106 0.28 / 1191.72 2 2
3 12 1935.92 70 9.09 3100 1973 2.25 / 1193.69 2 2
4 7 1930.32 24 10.66 3095 792 3.04 / 1194.48 2 2
5 13 1334.84 40 12.52 2264 1134 4.18 / 1195.61 2 2
6 13 361.80 40 13.66 881 481 4.66 / 1196.09 2 2
7 8 0.04 165 14.22 293 687 5.34 / 1196.78 2 2
Average= 4.95
(KJ/cycle)

Cycle 240 GMT 8/ 2/2023 4:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 28 14.10 452 178 0.18 / 1187.36 2 2
2 12 1123.76 70 6.01 1810 761 0.94 / 1188.12 2 2
3 7 1128.24 24 10.93 1960 514 1.45 / 1188.64 2 2
4 13 1160.92 40 12.18 2026 987 2.44 / 1189.62 2 2
5 13 1029.32 40 12.55 1853 930 3.37 / 1190.55 2 2
6 13 54.72 40 14.10 373 210 3.58 / 1190.77 2 2
7 8 0.08 165 14.20 287 672 4.25 / 1191.44 2 2
Average= 4.94
(KJ/cycle)

Cycle 239 GMT 29/ 1/2023 10:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 28 14.13 434 172 0.17 / 1182.89 2 2
2 12 1121.16 70 5.61 1781 699 0.87 / 1183.59 2 2
3 7 1125.52 24 10.86 1947 507 1.38 / 1184.09 2 2
4 13 1196.08 40 11.96 2080 995 2.37 / 1185.09 2 2
5 13 1097.72 40 12.36 1948 963 3.34 / 1186.05 2 2
6 13 333.20 40 13.64 830 453 3.79 / 1186.50 2 2
7 8 0.04 165 14.20 290 679 4.47 / 1187.18 2 2
Average= 4.95
(KJ/cycle)

Cycle 238 GMT 19/ 1/2023 15:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 28 14.11 452 179 0.18 / 1179.17 2 2
2 12 1124.84 70 7.65 1856 994 1.17 / 1180.16 2 2
3 7 1125.08 24 11.07 1969 523 1.70 / 1180.68 2 2
4 13 1014.72 40 12.47 1830 913 2.61 / 1181.60 2 2
5 13 305.04 40 13.69 775 424 3.03 / 1182.02 2 2
6 8 0.08 165 14.19 296 693 3.73 / 1182.71 2 2
Average= 4.95
(KJ/cycle)

Cycle 237 GMT 9/ 1/2023 21:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 28 14.13 441 174 0.17 / 1173.88 2 2
2 12 1105.52 5 11.06 1936 107 0.28 / 1173.98 2 2
3 12 1943.32 70 9.17 3128 2008 2.29 / 1175.99 2 2
4 7 1938.16 24 10.66 3150 806 3.10 / 1176.80 2 2
5 13 1210.08 40 12.67 2103 1066 4.16 / 1177.86 2 2
6 13 279.36 40 13.77 744 410 4.57 / 1178.27 2 2
7 8 0.08 165 14.22 305 716 5.29 / 1178.99 2 2
Average= 4.95
(KJ/cycle)

Cycle 236 GMT 8/ 1/2023 17:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 28 14.11 438 173 0.17 / 1169.54 2 2
2 12 1129.16 70 5.77 1854 749 0.92 / 1170.28 2 2
3 7 1133.76 24 10.99 1961 517 1.44 / 1170.80 2 2
4 13 1197.04 40 12.17 2083 1014 2.45 / 1171.82 2 2
5 13 958.36 40 12.79 1735 888 3.34 / 1172.70 2 2
6 13 187.56 40 13.89 583 324 3.66 / 1173.03 2 2
7 8 0.08 165 14.21 288 675 4.34 / 1173.70 2 2
Average= 4.95
(KJ/cycle)

Cycle 235 GMT 29/12/2022 23:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 28 14.13 439 174 0.17 / 1165.05 2 2
2 12 1132.68 70 5.60 1791 702 0.88 / 1165.75 2 2
3 7 1136.76 24 10.92 1959 513 1.39 / 1166.26 2 2
4 13 1201.16 40 12.00 2093 1005 2.39 / 1167.27 2 2
5 13 1098.88 40 12.43 1940 965 3.36 / 1168.23 2 2
6 13 348.00 40 13.62 843 459 3.82 / 1168.69 2 2
7 8 0.00 165 14.21 287 673 4.49 / 1169.36 2 2
Average= 4.95
(KJ/cycle)

Cycle 234 GMT 20/12/2022 4:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 28 14.12 460 182 0.18 / 1161.35 2 2
2 12 1135.00 70 7.64 1864 997 1.18 / 1162.35 2 2
3 7 1134.68 24 11.10 1968 524 1.70 / 1162.87 2 2
4 13 1020.32 40 12.54 1831 918 2.62 / 1163.79 2 2
5 13 291.88 40 13.71 749 411 3.03 / 1164.20 2 2
6 8 0.08 165 14.20 286 670 3.70 / 1164.87 2 2
Average= 4.96
(KJ/cycle)

Cycle 233 GMT 10/12/2022 10:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.52 28 14.08 451 178 0.18 / 1156.07 2 2
2 12 1123.40 5 11.09 1958 109 0.29 / 1156.18 2 2
3 12 1940.00 70 9.27 3127 2029 2.32 / 1158.21 2 2
4 7 1934.48 24 10.67 3127 801 3.12 / 1159.01 2 2
5 13 1213.44 40 12.69 2095 1063 4.18 / 1160.07 2 2
6 13 273.16 40 13.79 729 402 4.58 / 1160.48 2 2
7 8 0.00 165 14.24 295 693 5.27 / 1161.17 2 2
Average= 4.96
(KJ/cycle)

Cycle 232 GMT 9/12/2022 6:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 28 14.10 452 178 0.18 / 1151.54 2 2
2 12 1130.72 70 5.78 1853 750 0.93 / 1152.29 2 2
3 7 1135.00 24 11.02 1957 518 1.45 / 1152.80 2 2
4 13 1193.20 40 12.20 2078 1014 2.46 / 1153.82 2 2
5 13 1072.40 40 12.55 1912 960 3.42 / 1154.78 2 2
6 13 307.64 40 13.69 780 427 3.85 / 1155.21 2 2
7 8 0.04 165 14.20 294 689 4.54 / 1155.89 2 2
Average= 4.96
(KJ/cycle)

Cycle 231 GMT 29/11/2022 12:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 28 14.10 443 175 0.17 / 1147.05 2 2
2 12 1122.00 70 5.60 1799 705 0.88 / 1147.75 2 2
3 7 1126.08 24 10.94 1943 510 1.39 / 1148.27 2 2
4 13 1194.92 40 12.07 2087 1008 2.40 / 1149.27 2 2
5 13 1083.32 40 12.45 1934 963 3.36 / 1150.24 2 2
6 13 319.44 40 13.66 803 439 3.80 / 1150.67 2 2
7 8 0.04 165 14.20 292 684 4.48 / 1151.36 2 2
Average= 4.96
(KJ/cycle)

Cycle 230 GMT 19/11/2022 17:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 28 14.12 435 172 0.17 / 1143.31 2 2
2 12 1125.48 70 7.61 1854 988 1.16 / 1144.30 2 2
3 7 1126.68 24 11.09 1972 525 1.68 / 1144.82 2 2
4 13 1039.52 40 12.47 1864 930 2.61 / 1145.75 2 2
5 13 316.20 40 13.65 793 433 3.05 / 1146.19 2 2
6 8 0.04 165 14.18 294 688 3.74 / 1146.87 2 2
Average= 4.96
(KJ/cycle)

Cycle 229 GMT 9/11/2022 23:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 28 14.10 449 177 0.18 / 1138.07 2 2
2 12 1123.52 5 11.06 1935 107 0.28 / 1138.18 2 2
3 12 1939.20 70 9.00 3145 1981 2.27 / 1140.16 2 2
4 7 1933.92 24 10.64 3133 800 3.07 / 1140.96 2 2
5 13 1222.36 40 12.64 2118 1071 4.14 / 1142.03 2 2
6 13 291.68 40 13.73 764 420 4.56 / 1142.45 2 2
7 8 0.00 165 14.23 294 690 5.25 / 1143.14 2 2
Average= 4.97
(KJ/cycle)

Cycle 228 GMT 8/11/2022 19:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 28 14.09 449 177 0.18 / 1134.19 2 2
2 12 1128.84 70 6.35 1835 816 0.99 / 1135.01 2 2
3 7 1131.96 24 11.01 1973 521 1.51 / 1135.53 2 2
4 13 1090.44 40 12.36 1932 955 2.47 / 1136.48 2 2
5 13 695.28 40 13.12 1373 721 3.19 / 1137.20 2 2
6 8 0.00 165 14.21 294 689 3.88 / 1137.89 2 2
Average= 4.97
(KJ/cycle)

Cycle 227 GMT 30/10/2022 1:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 28 14.09 438 173 0.17 / 1129.78 2 2
2 12 1128.88 70 5.63 1808 713 0.89 / 1130.50 2 2
3 7 1132.80 24 10.98 1946 513 1.40 / 1131.01 2 2
4 13 1201.92 40 12.07 2084 1006 2.40 / 1132.02 2 2
5 13 1093.76 40 12.45 1941 967 3.37 / 1132.98 2 2
6 13 203.36 40 13.83 616 341 3.71 / 1133.32 2 2
7 8 0.00 165 14.19 295 691 4.40 / 1134.01 2 2
Average= 4.97
(KJ/cycle)

Cycle 226 GMT 20/10/2022 7: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 28 14.10 443 175 0.17 / 1126.11 2 2
2 12 1114.12 70 7.73 1846 999 1.17 / 1127.11 2 2
3 7 1114.40 24 11.22 1946 524 1.70 / 1127.63 2 2
4 13 1015.52 40 12.56 1819 914 2.61 / 1128.55 2 2
5 13 275.88 40 13.70 728 399 3.01 / 1128.94 2 2
6 8 0.08 165 14.19 285 667 3.68 / 1129.61 2 2
Average= 4.98
(KJ/cycle)

Cycle 225 GMT 10/10/2022 12:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 28 14.05 450 177 0.18 / 1120.91 2 2
2 12 1115.32 5 11.02 1929 106 0.28 / 1121.01 2 2
3 12 1934.84 70 9.04 3111 1969 2.25 / 1122.98 2 2
4 7 1929.32 24 10.72 3124 804 3.06 / 1123.78 2 2
5 13 1204.12 40 12.66 2091 1059 4.11 / 1124.84 2 2
6 13 297.88 40 13.71 770 422 4.54 / 1125.27 2 2
7 8 0.00 165 14.25 284 668 5.20 / 1125.93 2 2
Average= 4.98
(KJ/cycle)

Cycle 224 GMT 9/10/2022 8:58: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 28 14.09 455 180 0.18 / 1117.07 2 2
2 12 1123.76 70 6.26 1810 793 0.97 / 1117.87 2 2
3 7 1126.80 24 11.03 1979 524 1.50 / 1118.39 2 2
4 13 1079.52 40 12.35 1917 947 2.44 / 1119.34 2 2
5 13 696.28 40 13.13 1353 711 3.15 / 1120.05 2 2
6 8 0.08 165 14.22 290 680 3.83 / 1120.73 2 2
Average= 4.98
(KJ/cycle)

Cycle 223 GMT 29/ 9/2022 14:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 28 14.10 433 171 0.17 / 1113.11 2 2
2 12 1121.88 70 6.16 1804 778 0.95 / 1113.89 2 2
3 7 1125.68 24 11.03 1973 522 1.47 / 1114.41 2 2
4 13 1115.16 40 12.27 1976 970 2.44 / 1115.38 2 2
5 13 855.84 40 12.91 1596 824 3.27 / 1116.21 2 2
6 8 0.08 165 14.23 293 688 3.95 / 1116.89 2 2
Average= 4.99
(KJ/cycle)

Cycle 222 GMT 19/ 9/2022 20:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 28 14.11 447 177 0.18 / 1109.35 2 2
2 12 1120.08 70 7.86 1870 1029 1.21 / 1110.38 2 2
3 7 1120.76 24 11.23 1960 528 1.73 / 1110.91 2 2
4 13 1016.00 40 12.61 1832 924 2.66 / 1111.83 2 2
5 13 277.72 40 13.71 734 403 3.06 / 1112.23 2 2
6 8 0.08 165 14.19 302 707 3.77 / 1112.94 2 2
Average= 4.99
(KJ/cycle)

Cycle 221 GMT 10/ 9/2022 2:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 28 14.09 435 172 0.17 / 1104.10 2 2
2 12 1111.64 5 11.23 1939 109 0.28 / 1104.21 2 2
3 12 1944.04 70 9.27 3127 2029 2.31 / 1106.24 2 2
4 7 1939.32 24 10.72 3132 806 3.12 / 1107.05 2 2
5 13 1088.88 40 12.80 1938 992 4.11 / 1108.04 2 2
6 13 302.68 40 13.72 786 431 4.54 / 1108.47 2 2
7 8 0.12 165 14.24 300 705 5.24 / 1109.17 2 2
Average= 5.00
(KJ/cycle)

Cycle 220 GMT 8/ 9/2022 22:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 28 14.06 449 177 0.18 / 1099.59 2 2
2 12 1133.40 70 5.73 1863 747 0.92 / 1100.34 2 2
3 7 1137.84 24 11.05 1975 524 1.45 / 1100.86 2 2
4 13 1199.64 40 12.16 2097 1020 2.47 / 1101.88 2 2
5 13 1088.28 40 12.53 1923 964 3.43 / 1102.84 2 2
6 13 291.56 40 13.68 752 411 3.84 / 1103.26 2 2
7 8 -0.04 165 14.20 288 675 4.52 / 1103.93 2 2
Average= 5.00
(KJ/cycle)

Cycle 219 GMT 30/ 8/2022 4: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 28 14.07 438 173 0.17 / 1095.69 2 2
2 12 1122.60 70 6.21 1793 779 0.95 / 1096.47 2 2
3 7 1125.72 24 11.02 1970 521 1.47 / 1096.99 2 2
4 13 1099.52 40 12.32 1941 957 2.43 / 1097.94 2 2
5 13 832.40 40 12.94 1542 798 3.23 / 1098.74 2 2
6 8 0.20 165 14.24 285 670 3.90 / 1099.41 2 2
Average= 5.00
(KJ/cycle)

Cycle 218 GMT 20/ 8/2022 9:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 28 14.10 440 174 0.17 / 1091.94 2 2
2 12 1130.96 70 8.02 1871 1050 1.22 / 1092.99 2 2
3 7 1130.56 24 11.24 1969 531 1.76 / 1093.52 2 2
4 13 1017.60 40 12.61 1832 924 2.68 / 1094.45 2 2
5 13 265.56 40 13.73 711 390 3.07 / 1094.84 2 2
6 8 -0.04 165 14.20 289 677 3.75 / 1095.52 2 2
Average= 5.00
(KJ/cycle)

Cycle 217 GMT 10/ 8/2022 15:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 28 14.08 450 177 0.18 / 1086.68 2 2
2 12 1113.76 5 11.29 1926 109 0.29 / 1086.79 2 2
3 12 1936.88 70 9.25 3108 2012 2.30 / 1088.80 2 2
4 7 1931.68 24 10.72 3132 806 3.10 / 1089.61 2 2
5 13 1216.36 40 12.64 2102 1063 4.17 / 1090.67 2 2
6 13 281.44 40 13.74 744 409 4.58 / 1091.08 2 2
7 8 0.16 165 14.23 294 690 5.27 / 1091.77 2 2
Average= 5.01
(KJ/cycle)

Cycle 216 GMT 9/ 8/2022 11:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 28 14.07 446 176 0.18 / 1082.63 2 2
2 12 1134.84 70 6.27 1852 813 0.99 / 1083.44 2 2
3 7 1138.20 24 11.07 1992 529 1.52 / 1083.97 2 2
4 13 1102.24 40 12.39 1939 961 2.48 / 1084.93 2 2
5 13 971.96 40 12.71 1756 893 3.37 / 1085.83 2 2
6 8 0.12 165 14.24 287 674 4.05 / 1086.50 2 2
Average= 5.01
(KJ/cycle)

Cycle 215 GMT 30/ 7/2022 17:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 28 14.10 439 173 0.17 / 1078.56 2 2
2 12 1131.96 70 6.44 1825 823 1.00 / 1079.39 2 2
3 7 1134.80 24 11.10 1986 529 1.53 / 1079.91 2 2
4 13 1079.36 40 12.38 1916 949 2.47 / 1080.86 2 2
5 13 672.72 40 13.14 1329 699 3.17 / 1081.56 2 2
6 13 28.96 40 14.16 341 193 3.37 / 1081.76 2 2
7 8 0.08 165 14.21 299 701 4.07 / 1082.46 2 2
Average= 5.01
(KJ/cycle)

Cycle 214 GMT 20/ 7/2022 23:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 28 14.10 458 181 0.18 / 1074.79 2 2
2 12 1129.48 70 7.98 1885 1053 1.23 / 1075.84 2 2
3 7 1128.72 24 11.25 1992 538 1.77 / 1076.38 2 2
4 13 1019.04 40 12.62 1839 928 2.70 / 1077.31 2 2
5 13 277.28 40 13.69 737 404 3.10 / 1077.71 2 2
6 8 0.04 165 14.21 290 680 3.78 / 1078.39 2 2
Average= 5.02
(KJ/cycle)

Cycle 213 GMT 11/ 7/2022 5:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 28 14.07 437 172 0.17 / 1069.48 2 2
2 12 1119.68 5 11.23 1966 110 0.28 / 1069.59 2 2
3 12 1937.72 70 9.26 3122 2024 2.31 / 1071.61 2 2
4 7 1932.44 24 10.71 3140 807 3.11 / 1072.42 2 2
5 13 1220.68 40 12.61 2123 1071 4.18 / 1073.49 2 2
6 13 286.32 40 13.72 756 415 4.60 / 1073.91 2 2
7 8 -0.04 165 14.23 298 700 5.30 / 1074.61 2 2
Average= 5.02
(KJ/cycle)

Cycle 212 GMT 10/ 7/2022 1:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 28 14.07 444 175 0.17 / 1065.71 2 2
2 12 1119.00 70 6.52 1824 832 1.01 / 1066.55 2 2
3 7 1121.40 24 11.13 1977 528 1.54 / 1067.07 2 2
4 13 1059.72 40 12.42 1902 945 2.48 / 1068.02 2 2
5 13 515.04 40 13.33 1112 593 3.07 / 1068.61 2 2
6 8 0.12 165 14.22 296 695 3.77 / 1069.31 2 2
Average= 5.02
(KJ/cycle)

Cycle 211 GMT 30/ 6/2022 7:25: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 28 14.10 430 170 0.17 / 1061.57 2 2
2 12 1134.88 70 6.44 1843 831 1.00 / 1062.40 2 2
3 7 1137.88 24 11.11 2005 535 1.54 / 1062.94 2 2
4 13 1078.52 40 12.40 1917 951 2.49 / 1063.89 2 2
5 13 802.80 40 12.97 1524 791 3.28 / 1064.68 2 2
6 13 31.32 40 14.18 334 189 3.47 / 1064.87 2 2
7 8 0.00 165 14.25 285 670 4.14 / 1065.54 2 2
Average= 5.03
(KJ/cycle)

Cycle 210 GMT 20/ 6/2022 13:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 28 14.10 431 170 0.17 / 1057.82 2 2
2 12 1127.80 70 8.22 1894 1090 1.26 / 1058.91 2 2
3 7 1127.08 24 11.33 1987 540 1.80 / 1059.45 2 2
4 13 1008.68 40 12.65 1817 919 2.72 / 1060.37 2 2
5 13 246.28 40 13.75 676 372 3.09 / 1060.74 2 2
6 8 0.08 165 14.23 281 660 3.75 / 1061.40 2 2
Average= 5.03
(KJ/cycle)

Cycle 209 GMT 10/ 6/2022 19:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 28 14.11 443 175 0.18 / 1052.54 2 2
2 12 1116.16 5 11.35 1978 112 0.29 / 1052.66 2 2
3 12 1931.28 70 9.35 3118 2041 2.33 / 1054.70 2 2
4 7 1925.88 24 10.76 3128 808 3.14 / 1055.51 2 2
5 13 1202.80 40 12.65 2097 1061 4.20 / 1056.57 2 2
6 13 278.64 40 13.74 735 404 4.60 / 1056.97 2 2
7 8 0.12 165 14.25 290 682 5.28 / 1057.65 2 2
Average= 5.04
(KJ/cycle)

Cycle 208 GMT 9/ 6/2022 15:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 29 14.14 426 175 0.17 / 1048.64 2 2
2 3 969.64 -1 15.17 0 0 0.00 / 1048.64 2 2
3 12 1137.04 70 6.66 1855 865 1.04 / 1049.51 2 2
4 7 1139.80 24 11.13 2010 537 1.58 / 1050.04 2 2
5 13 1082.28 40 12.42 1919 953 2.53 / 1051.00 2 2
6 13 662.12 40 13.16 1326 698 3.23 / 1051.70 2 2
7 8 0.04 165 14.26 286 673 3.90 / 1052.37 2 2
Average= 5.04
(KJ/cycle)

Cycle 207 GMT 30/ 5/2022 21:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 28 14.09 442 174 0.17 / 1044.68 2 2
2 12 1134.00 70 6.72 1849 870 1.04 / 1045.55 2 2
3 7 1136.60 24 11.19 1984 533 1.58 / 1046.08 2 2
4 13 1071.24 40 12.44 1894 942 2.52 / 1047.02 2 2
5 13 796.20 40 13.00 1489 774 3.29 / 1047.80 2 2
6 8 0.08 165 14.25 286 672 3.97 / 1048.47 2 2
Average= 5.04
(KJ/cycle)

Cycle 206 GMT 21/ 5/2022 3:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 28 14.11 443 175 0.18 / 1040.90 2 2
2 12 1123.64 70 8.33 1897 1106 1.28 / 1042.00 2 2
3 7 1122.92 24 11.35 1976 538 1.82 / 1042.54 2 2
4 13 1015.64 40 12.66 1836 930 2.75 / 1043.47 2 2
5 13 238.08 40 13.76 665 366 3.12 / 1043.84 2 2
6 8 0.16 165 14.23 284 667 3.78 / 1044.50 2 2
Average= 5.05
(KJ/cycle)

Cycle 205 GMT 11/ 5/2022 9:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 28 14.09 444 175 0.18 / 1035.62 2 2
2 12 1110.28 5 11.36 1936 110 0.29 / 1035.73 2 2
3 12 1932.00 70 9.40 3114 2049 2.33 / 1037.78 2 2
4 7 1926.56 24 10.76 3130 808 3.14 / 1038.59 2 2
5 13 1205.48 40 12.64 2110 1067 4.21 / 1039.65 2 2
6 13 252.04 40 13.78 696 384 4.59 / 1040.04 2 2
7 8 0.08 165 14.25 291 684 5.28 / 1040.72 2 2
Average= 5.05
(KJ/cycle)

Cycle 204 GMT 10/ 5/2022 5:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 28 14.11 440 174 0.17 / 1031.67 2 2
2 10 1001.52 3 12.44 1803 67 0.24 / 1031.74 2 2
3 3 940.24 -1 15.19 0 0 0.07 / 1031.74 2 2
4 12 1118.60 70 6.92 1850 896 1.14 / 1032.63 2 2
5 7 1120.92 24 11.21 1991 536 1.67 / 1033.17 2 2
6 13 1051.56 40 12.49 1887 943 2.62 / 1034.11 2 2
7 13 611.52 40 13.23 1240 656 3.27 / 1034.77 2 2
8 8 0.16 165 14.25 288 677 3.95 / 1035.44 2 2
Average= 5.05
(KJ/cycle)

Cycle 203 GMT 30/ 4/2022 11:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 28 14.11 435 172 0.17 / 1027.84 2 2
2 12 1132.92 70 6.98 1863 910 1.08 / 1028.75 2 2
3 7 1135.52 24 11.25 2000 540 1.62 / 1029.29 2 2
4 13 1061.92 40 12.51 1904 953 2.57 / 1030.24 2 2
5 13 487.92 40 13.37 1081 578 3.15 / 1030.82 2 2
6 8 0.04 165 14.26 286 673 3.83 / 1031.49 2 2
Average= 5.06
(KJ/cycle)

Cycle 202 GMT 20/ 4/2022 17:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 28 14.11 444 175 0.18 / 1024.03 2 2
2 12 1128.12 70 8.59 1902 1144 1.32 / 1025.17 2 2
3 7 1126.80 24 11.38 1990 544 1.86 / 1025.71 2 2
4 13 1008.84 40 12.66 1813 918 2.78 / 1026.63 2 2
5 13 242.36 40 13.76 675 372 3.15 / 1027.00 2 2
6 8 -0.04 165 14.23 283 664 3.82 / 1027.67 2 2
Average= 5.06
(KJ/cycle)

Cycle 201 GMT 10/ 4/2022 23:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 28 14.13 436 172 0.17 / 1018.58 2 2
2 12 1117.36 5 11.38 1986 113 0.29 / 1018.70 2 2
3 12 1925.64 70 9.53 3105 2071 2.36 / 1020.77 2 2
4 7 1919.64 24 10.78 3134 811 3.17 / 1021.58 2 2
5 13 1314.12 40 12.53 2254 1130 4.30 / 1022.71 2 2
6 13 339.92 40 13.63 848 462 4.76 / 1023.17 2 2
7 8 0.08 165 14.26 290 682 5.44 / 1023.85 2 2
Average= 5.07
(KJ/cycle)

Cycle 200 GMT 9/ 4/2022 19:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 28 14.11 438 173 0.17 / 1014.63 2 2
2 12 1133.84 70 6.89 1860 897 1.07 / 1015.53 2 2
3 7 1135.56 24 11.19 1983 533 1.60 / 1016.06 2 2
4 13 1047.04 40 12.45 1870 931 2.53 / 1016.99 2 2
5 13 466.24 40 13.39 1034 554 3.09 / 1017.55 2 2
6 8 0.12 165 14.23 290 681 3.77 / 1018.23 2 2
7 14 0.12 45 14.26 286 184 3.95 / 1018.41 2 2
Average= 5.07
(KJ/cycle)

Cycle 199 GMT 31/ 3/2022 1:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 28 14.11 437 173 0.17 / 1010.90 2 2
2 12 1121.12 70 7.50 1868 981 1.15 / 1011.88 2 2
3 7 1121.56 24 11.26 1969 532 1.69 / 1012.42 2 2
4 13 1019.12 40 12.51 1839 920 2.61 / 1013.34 2 2
5 13 329.44 40 13.58 828 450 3.06 / 1013.79 2 2
6 8 0.00 165 14.24 286 672 3.73 / 1014.46 2 2
Average= 5.07
(KJ/cycle)

Cycle 198 GMT 21/ 3/2022 7:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 28 14.16 429 170 0.17 / 1007.16 2 2
2 12 1130.80 70 8.88 1915 1190 1.36 / 1008.35 2 2
3 7 1128.60 24 11.43 1978 543 1.90 / 1008.89 2 2
4 13 997.72 40 12.67 1799 912 2.81 / 1009.80 2 2
5 13 102.76 40 14.02 450 252 3.07 / 1010.06 2 2
6 8 0.04 165 14.24 287 674 3.74 / 1010.73 2 2
Average= 5.08
(KJ/cycle)

Cycle 197 GMT 11/ 3/2022 13:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 28 14.16 433 172 0.17 / 1002.11 2 2
2 12 1096.20 5 11.58 1901 110 0.28 / 1002.22 2 2
3 12 1925.60 70 9.60 3090 2076 2.36 / 1004.29 2 2
4 7 1919.88 24 10.77 3122 807 3.17 / 1005.10 2 2
5 13 1053.80 40 12.83 1872 961 4.13 / 1006.06 2 2
6 13 132.16 40 14.05 486 273 4.40 / 1006.33 2 2
7 8 0.12 165 14.29 278 655 5.05 / 1006.99 2 2
Average= 5.09
(KJ/cycle)

Cycle 196 GMT 10/ 3/2022 9:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 30 14.17 419 178 0.18 / 998.39 2 2
2 3 922.84 -1 15.21 0 0 0.00 / 998.39 2 2
3 3 962.44 -1 15.20 0 0 0.00 / 998.39 2 2
4 12 1126.40 70 7.59 1877 997 1.18 / 999.38 2 2
5 7 1127.04 24 11.30 1971 535 1.71 / 999.92 2 2
6 13 1024.76 40 12.55 1836 922 2.63 / 1000.84 2 2
7 13 307.64 40 13.64 782 427 3.06 / 1001.27 2 2
8 8 0.00 165 14.25 284 668 3.73 / 1001.93 2 2
Average= 5.09
(KJ/cycle)

Cycle 195 GMT 28/ 2/2022 15:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 28 14.14 434 172 0.17 / 994.61 2 2
2 12 1122.84 70 8.41 1901 1119 1.29 / 995.73 2 2
3 7 1122.04 24 11.41 1966 538 1.83 / 996.27 2 2
4 13 1012.88 40 12.70 1810 919 2.75 / 997.19 2 2
5 13 235.16 40 13.79 657 362 3.11 / 997.55 2 2
6 8 0.16 165 14.26 280 659 3.77 / 998.21 2 2
Average= 5.09
(KJ/cycle)

Cycle 194 GMT 18/ 2/2022 21:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 28 14.20 435 173 0.17 / 991.02 2 2
2 12 1124.96 70 9.59 1919 1288 1.46 / 992.31 2 2
3 7 1122.08 24 11.51 1961 542 2.00 / 992.85 2 2
4 13 731.96 40 13.14 1408 740 2.74 / 993.59 2 2
5 13 50.84 40 14.19 353 200 2.94 / 993.79 2 2
6 8 -0.12 165 14.29 276 651 3.59 / 994.44 2 2
Average= 5.10
(KJ/cycle)

Cycle 193 GMT 9/ 2/2022 3:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 32 14.15 458 207 0.21 / 985.80 2 2
2 3 851.28 -3 15.22 0 0 0.00 / 985.80 2 2
3 12 1083.00 5 11.92 1924 115 0.32 / 985.91 2 2
4 12 1914.08 70 10.06 3086 2173 2.50 / 988.08 2 2
5 7 1908.20 24 10.94 3103 815 3.31 / 988.90 2 2
6 13 1154.00 40 12.76 2018 1030 4.34 / 989.93 2 2
7 13 93.12 40 14.14 438 248 4.59 / 990.18 2 2
8 8 0.08 165 14.31 283 668 5.26 / 990.84 2 2
Average= 5.11
(KJ/cycle)

Cycle 192 GMT 7/ 2/2022 23:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 1112.32 8 12.72 1930 196 0.20 / 981.47 2 2
2 3 1113.96 3 12.89 1944 75 0.27 / 981.54 2 2
3 3 1557.68 14 11.91 2609 435 0.71 / 981.98 2 2
4 12 1393.52 70 11.58 2379 1928 2.64 / 983.91 2 2
5 7 1386.44 24 11.45 2369 651 3.29 / 984.56 2 2
6 13 224.76 40 13.84 642 355 3.64 / 984.91 2 2
7 8 0.04 165 14.27 287 676 4.32 / 985.59 2 2
Average= 5.11
(KJ/cycle)

Cycle 191 GMT 7/ 2/2022 13:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 28 14.14 426 169 0.17 / 977.68 2 2
2 12 1140.60 70 7.78 1930 1051 1.22 / 978.73 2 2
3 7 1140.60 24 11.25 1991 538 1.76 / 979.27 2 2
4 13 1038.48 40 12.44 1856 924 2.68 / 980.19 2 2
5 13 304.96 40 13.62 774 422 3.10 / 980.61 2 2
6 8 0.04 165 14.24 280 658 3.76 / 981.27 2 2
Average= 5.11
(KJ/cycle)

Cycle 190 GMT 28/ 1/2022 19:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 27 14.20 421 161 0.16 / 974.00 2 2
2 12 1134.72 70 9.13 1934 1236 1.40 / 975.24 2 2
3 7 1132.12 24 11.46 1967 541 1.94 / 975.78 2 2
4 13 883.08 40 12.86 1610 828 2.77 / 976.61 2 2
5 13 115.68 40 14.02 452 253 3.02 / 976.86 2 2
6 8 0.00 165 14.26 276 649 3.67 / 977.51 2 2
Average= 5.12
(KJ/cycle)

Cycle 189 GMT 19/ 1/2022 1:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 1087.12 8 12.97 1894 197 0.20 / 968.11 2 2
2 10 1161.56 7 13.11 2001 184 0.38 / 968.29 2 2
3 10 1218.76 5 13.09 2101 138 0.52 / 968.43 2 2
4 10 1259.40 4 13.10 2168 114 0.63 / 968.54 2 2
5 3 1346.04 9 12.39 2307 257 0.89 / 968.80 2 2
6 3 1135.36 3 12.41 2018 75 0.96 / 968.88 2 2
7 12 1163.80 5 11.95 2045 122 1.09 / 969.00 2 2
8 12 1922.20 70 10.20 3108 2219 3.30 / 971.22 2 2
9 7 1916.56 24 10.88 3110 812 4.12 / 972.03 2 2
10 13 1016.60 40 12.94 1820 942 5.06 / 972.97 2 2
11 13 55.72 40 14.23 366 208 5.27 / 973.18 2 2
12 8 0.04 165 14.35 279 661 5.93 / 973.84 2 2
Average= 5.13
(KJ/cycle)

Cycle 188 GMT 17/ 1/2022 22: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 27 14.23 432 166 0.17 / 959.84 2 2
2 12 1132.88 4 5.82 2187 51 0.22 / 959.89 2 2
3 12 2001.52 100 5.94 3277 1947 2.16 / 961.84 2 2
4 12 2005.72 70 6.28 3375 1484 3.65 / 963.32 2 2
5 7 2004.80 25 10.77 3270 880 4.53 / 964.20 2 2
6 13 1909.08 40 11.80 3111 1468 6.00 / 965.67 2 2
7 13 1343.36 40 12.58 2292 1153 7.15 / 966.82 2 2
8 13 289.12 40 13.76 749 412 7.56 / 967.23 2 2
9 8 0.00 165 14.33 287 679 8.24 / 967.91 2 2
Average= 5.12
(KJ/cycle)

Cycle 187 GMT 7/ 1/2022 22:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 28 14.22 432 172 0.17 / 951.41 2 2
2 12 1114.84 4 6.70 1904 51 0.22 / 951.46 2 2
3 12 2000.84 100 5.92 3202 1896 2.12 / 953.36 2 2
4 12 2001.84 70 6.01 3385 1424 3.54 / 954.78 2 2
5 7 2001.44 24 10.76 3234 835 4.38 / 955.62 2 2
6 13 1903.52 40 11.82 3111 1471 5.85 / 957.09 2 2
7 13 1506.72 40 12.40 2528 1254 7.10 / 958.34 2 2
8 13 575.60 40 13.41 1184 635 7.74 / 958.98 2 2
9 8 0.04 165 14.33 295 698 8.44 / 959.67 2 2
Average= 5.10
(KJ/cycle)

Cycle 186 GMT 28/12/2021 22:51:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 28 14.20 440 175 0.17 / 942.98 2 2
2 12 1127.20 4 5.87 2004 47 0.22 / 943.02 2 2
3 12 2002.68 100 5.89 3010 1773 1.99 / 944.80 2 2
4 12 2009.96 70 5.89 3392 1399 3.39 / 946.19 2 2
5 7 2011.88 24 10.74 3233 833 4.23 / 947.03 2 2
6 13 1948.72 40 11.75 3165 1488 5.71 / 948.51 2 2
7 13 1540.68 40 12.37 2587 1280 6.99 / 949.79 2 2
8 13 765.48 40 13.22 1457 770 7.76 / 950.57 2 2
9 8 0.00 165 14.35 284 672 8.44 / 951.24 2 2
Average= 5.09
(KJ/cycle)

Cycle 185 GMT 18/12/2021 23:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 28 14.22 433 172 0.17 / 934.91 2 2
2 12 1122.64 4 5.82 2091 49 0.22 / 934.96 2 2
3 12 2003.24 100 5.97 3269 1952 2.17 / 936.91 2 2
4 12 2006.24 70 6.38 3360 1501 3.67 / 938.41 2 2
5 7 2004.32 24 10.79 3279 849 4.52 / 939.26 2 2
6 13 1882.80 40 11.85 3069 1455 5.98 / 940.72 2 2
7 13 1169.24 40 12.77 2032 1038 7.02 / 941.75 2 2
8 13 247.32 40 13.83 676 374 7.39 / 942.13 2 2
9 8 -0.04 165 14.32 285 673 8.06 / 942.80 2 2
Average= 5.07
(KJ/cycle)

Cycle 184 GMT 9/12/2021 0:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 28 14.22 441 176 0.18 / 926.73 2 2
2 12 1117.72 4 5.71 1992 45 0.22 / 926.77 2 2
3 12 2001.92 100 5.91 3056 1806 2.03 / 928.58 2 2
4 12 2006.72 70 5.91 3432 1420 3.45 / 930.00 2 2
5 7 2008.00 24 10.84 3230 840 4.29 / 930.84 2 2
6 13 1932.52 40 11.85 3128 1483 5.77 / 932.32 2 2
7 13 1381.96 40 12.58 2336 1175 6.95 / 933.50 2 2
8 13 470.92 40 13.52 1036 560 7.51 / 934.06 2 2
9 8 0.04 165 14.33 287 679 8.18 / 934.74 2 2
Average= 5.05
(KJ/cycle)

Cycle 183 GMT 29/11/2021 1:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 28 14.23 440 175 0.18 / 918.42 2 2
2 12 1121.84 4 6.15 1900 47 0.22 / 918.47 2 2
3 12 2000.68 100 5.92 3126 1851 2.07 / 920.32 2 2
4 12 2005.48 70 6.18 3398 1470 3.54 / 921.79 2 2
5 7 2004.92 24 10.88 3277 856 4.40 / 922.65 2 2
6 13 1909.04 40 11.85 3111 1475 5.87 / 924.12 2 2
7 13 1344.84 40 12.63 2280 1152 7.02 / 925.27 2 2
8 13 536.04 40 13.47 1111 599 7.62 / 925.87 2 2
9 8 0.08 165 14.32 289 683 8.31 / 926.55 2 2
Average= 5.04
(KJ/cycle)

Cycle 182 GMT 19/11/2021 2:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 28 14.23 443 177 0.18 / 910.31 2 2
2 12 1114.48 4 5.75 1984 46 0.22 / 910.35 2 2
3 12 2004.00 100 5.93 3186 1889 2.11 / 912.24 2 2
4 12 2009.12 70 6.14 3372 1449 3.56 / 913.69 2 2
5 7 2008.88 24 10.87 3260 850 4.41 / 914.54 2 2
6 13 1918.24 40 11.86 3122 1481 5.89 / 916.02 2 2
7 13 1234.24 40 12.73 2149 1094 6.99 / 917.12 2 2
8 13 333.16 40 13.70 823 451 7.44 / 917.57 2 2
9 8 -0.04 165 14.32 288 680 8.12 / 918.25 2 2
Average= 5.02
(KJ/cycle)

Cycle 181 GMT 9/11/2021 2:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 28 14.24 437 174 0.17 / 902.07 2 2
2 12 1116.84 4 5.69 1855 42 0.22 / 902.11 2 2
3 12 2006.40 100 5.87 2976 1747 1.96 / 903.86 2 2
4 12 2011.72 70 5.84 3221 1317 3.28 / 905.18 2 2
5 7 2013.08 24 10.78 3233 836 4.12 / 906.01 2 2
6 13 1938.28 40 11.82 3129 1479 5.60 / 907.49 2 2
7 13 1525.88 40 12.46 2580 1286 6.88 / 908.78 2 2
8 13 616.44 40 13.40 1237 663 7.54 / 909.44 2 2
9 8 0.12 165 14.33 291 688 8.23 / 910.13 2 2
Average= 5.00
(KJ/cycle)

Cycle 180 GMT 30/10/2021 3: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 28 14.23 430 171 0.17 / 893.96 2 2
2 12 1109.92 4 5.65 1858 42 0.21 / 894.00 2 2
3 12 2002.20 100 5.81 2751 1598 1.81 / 895.60 2 2
4 12 2004.44 70 5.85 3170 1298 3.11 / 896.90 2 2
5 7 2005.00 24 10.81 3227 837 3.95 / 897.73 2 2
6 13 1923.64 40 11.76 3115 1465 5.41 / 899.20 2 2
7 13 1524.04 40 12.45 2558 1274 6.69 / 900.47 2 2
8 13 734.20 40 13.29 1398 743 7.43 / 901.22 2 2
9 8 0.00 165 14.34 288 681 8.11 / 901.90 2 2
Average= 4.98
(KJ/cycle)

Cycle 179 GMT 20/10/2021 3:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.64 27 14.25 441 170 0.17 / 886.57 2 2
2 12 1122.12 4 5.75 1888 43 0.21 / 886.61 2 2
3 12 2005.20 100 6.17 3232 1994 2.21 / 888.60 2 2
4 12 2004.12 70 7.39 3219 1665 3.87 / 890.27 2 2
5 7 1999.56 24 10.95 3244 853 4.72 / 891.12 2 2
6 13 1585.08 40 12.30 2653 1305 6.03 / 892.43 2 2
7 13 651.80 40 13.34 1284 685 6.72 / 893.11 2 2
8 8 0.24 165 14.33 285 674 7.39 / 893.79 2 2
Average= 4.97
(KJ/cycle)

Cycle 178 GMT 10/10/2021 4:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 27 14.26 437 168 0.17 / 878.42 2 2
2 12 1116.24 4 5.67 1736 39 0.21 / 878.46 2 2
3 12 2003.80 100 5.86 2917 1709 1.92 / 880.17 2 2
4 12 2007.40 70 5.92 3415 1415 3.33 / 881.59 2 2
5 7 2008.40 24 10.96 3239 852 4.18 / 882.44 2 2
6 13 1937.96 40 11.94 3140 1500 5.68 / 883.94 2 2
7 13 1392.16 40 12.63 2358 1191 6.88 / 885.13 2 2
8 13 492.44 40 13.51 1079 583 7.46 / 885.71 2 2
9 8 0.12 165 14.32 290 685 8.14 / 886.40 2 2
Average= 4.95
(KJ/cycle)

Cycle 177 GMT 30/ 9/2021 4:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 27 14.25 443 170 0.17 / 870.45 2 2
2 12 1129.72 4 5.65 1663 38 0.21 / 870.49 2 2
3 12 2003.20 100 5.88 2952 1736 1.94 / 872.23 2 2
4 12 2006.80 70 6.42 3376 1517 3.46 / 873.74 2 2
5 7 2005.36 24 11.03 3256 862 4.32 / 874.60 2 2
6 13 1901.48 40 12.00 3108 1492 5.81 / 876.10 2 2
7 13 1192.96 40 12.83 2079 1067 6.88 / 877.16 2 2
8 13 259.48 40 13.83 715 396 7.28 / 877.56 2 2
9 8 0.00 165 14.31 294 694 7.97 / 878.25 2 2
Average= 4.93
(KJ/cycle)

Cycle 176 GMT 20/ 9/2021 5: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 27 14.24 442 170 0.17 / 862.79 2 2
2 12 1116.56 4 5.69 1709 39 0.21 / 862.83 2 2
3 12 2004.88 100 5.94 3187 1893 2.10 / 864.72 2 2
4 12 2007.36 70 6.95 3249 1581 3.68 / 866.30 2 2
5 7 2004.16 24 11.06 3273 869 4.55 / 867.17 2 2
6 13 1878.64 40 12.07 3072 1483 6.03 / 868.66 2 2
7 13 994.68 40 13.04 1789 933 6.97 / 869.59 2 2
8 8 0.20 165 14.36 292 692 7.66 / 870.28 2 2
Average= 4.92
(KJ/cycle)

Cycle 175 GMT 10/ 9/2021 5:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 27 14.25 429 165 0.17 / 855.10 2 2
2 12 1119.04 4 5.69 1553 35 0.20 / 855.14 2 2
3 12 2003.64 100 5.82 2757 1605 1.80 / 856.74 2 2
4 12 2007.28 50 5.87 3274 961 2.77 / 857.71 2 2
5 7 2008.36 24 10.96 3225 848 3.61 / 858.55 2 2
6 13 1922.64 40 11.94 3096 1479 5.09 / 860.03 2 2
7 13 1501.48 40 12.56 2514 1263 6.36 / 861.30 2 2
8 13 580.84 40 13.46 1186 639 6.99 / 861.93 2 2
9 8 0.00 165 14.33 291 688 7.68 / 862.62 2 2
Average= 4.90
(KJ/cycle)

Cycle 174 GMT 31/ 8/2021 6:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 27 14.29 441 170 0.17 / 848.58 2 2
2 12 1123.60 4 5.64 1597 36 0.21 / 848.61 2 2
3 12 2004.04 100 6.92 3042 2105 2.31 / 850.72 2 2
4 12 1998.20 50 7.32 3190 1168 3.48 / 851.89 2 2
5 7 1992.76 24 11.01 3229 853 4.33 / 852.74 2 2
6 13 1265.36 40 12.72 2162 1100 5.43 / 853.84 2 2
7 13 314.04 40 13.72 787 432 5.86 / 854.27 2 2
8 8 0.08 165 14.31 283 668 6.53 / 854.94 2 2
Average= 4.89
(KJ/cycle)

Cycle 173 GMT 21/ 8/2021 7: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 27 14.25 433 167 0.17 / 840.79 2 2
2 12 1115.56 4 5.72 1484 34 0.20 / 840.82 2 2
3 12 2004.88 100 5.85 2863 1675 1.88 / 842.49 2 2
4 12 2008.92 50 6.13 3383 1037 2.91 / 843.53 2 2
5 7 2009.32 24 11.14 3263 872 3.78 / 844.40 2 2
6 13 1926.24 40 12.08 3143 1519 5.30 / 845.92 2 2
7 13 1501.16 40 12.62 2532 1278 6.58 / 847.20 2 2
8 13 410.56 40 13.65 953 520 7.10 / 847.72 2 2
9 8 0.08 165 14.34 290 686 7.79 / 848.41 2 2
Average= 4.88
(KJ/cycle)

Cycle 172 GMT 11/ 8/2021 7:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 27 14.30 431 166 0.17 / 834.46 2 2
2 12 1122.52 2 5.65 1282 14 0.18 / 834.47 2 2
3 12 2005.56 81 6.31 3002 1534 1.72 / 836.01 2 2
4 12 2006.24 40 8.02 3226 1035 2.75 / 837.04 2 2
5 7 2002.44 24 11.05 3267 866 3.62 / 837.91 2 2
6 13 1596.64 40 12.40 2662 1320 4.94 / 839.23 2 2
7 13 706.60 40 13.31 1362 725 5.66 / 839.95 2 2
8 8 0.08 165 14.34 281 665 6.33 / 840.62 2 2
Average= 4.86
(KJ/cycle)

Cycle 171 GMT 1/ 8/2021 8:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 27 14.29 437 169 0.17 / 827.46 2 2
2 12 1114.24 2 5.66 1282 15 0.18 / 827.48 2 2
3 12 2002.28 81 5.88 2955 1407 1.59 / 828.88 2 2
4 12 2004.60 40 6.93 3285 911 2.50 / 829.79 2 2
5 7 2002.80 24 11.14 3267 873 3.37 / 830.67 2 2
6 13 1888.52 40 12.17 3068 1494 4.87 / 832.16 2 2
7 13 1295.64 40 12.80 2209 1131 6.00 / 833.29 2 2
8 13 199.56 40 13.99 599 335 6.33 / 833.63 2 2
9 8 -0.08 165 14.34 281 665 7.00 / 834.29 2 2
Average= 4.85
(KJ/cycle)

Cycle 170 GMT 22/ 7/2021 9:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 27 14.29 448 173 0.17 / 821.31 2 2
2 12 2007.24 81 6.27 2958 1502 1.68 / 822.81 2 2
3 7 2006.20 24 11.07 3267 868 2.54 / 823.68 2 2
4 13 1905.36 40 12.10 3080 1491 4.03 / 825.17 2 2
5 13 1187.60 40 12.85 2062 1060 5.09 / 826.23 2 2
6 13 271.32 40 13.84 716 396 5.49 / 826.62 2 2
7 8 -0.08 165 14.31 284 671 6.16 / 827.29 2 2
Average= 4.84
(KJ/cycle)

Cycle 169 GMT 12/ 7/2021 10:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 27 14.27 447 172 0.17 / 815.14 2 2
2 12 2003.92 81 6.03 2917 1425 1.60 / 816.56 2 2
3 7 2003.60 24 11.15 3209 859 2.46 / 817.42 2 2
4 13 1907.64 40 12.12 3108 1507 3.96 / 818.93 2 2
5 13 1221.24 40 12.84 2102 1080 5.04 / 820.01 2 2
6 13 317.92 40 13.76 801 441 5.48 / 820.45 2 2
7 8 0.00 165 14.31 289 682 6.17 / 821.13 2 2
Average= 4.83
(KJ/cycle)

Cycle 168 GMT 2/ 7/2021 10:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.84 27 14.25 458 176 0.18 / 809.10 2 2
2 12 2010.52 47 5.83 2617 717 0.89 / 809.82 2 2
3 7 2011.88 24 11.17 3233 867 1.76 / 810.68 2 2
4 13 1938.40 40 11.97 3154 1510 3.27 / 812.19 2 2
5 13 1525.68 40 12.49 2564 1281 4.55 / 813.48 2 2
6 13 578.64 40 13.44 1178 633 5.18 / 814.11 2 2
7 13 17.44 40 14.31 311 178 5.36 / 814.29 2 2
8 8 -0.04 165 14.27 289 680 6.04 / 814.97 2 2
Average= 4.82
(KJ/cycle)

Cycle 167 GMT 22/ 6/2021 11: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 27 14.28 448 173 0.17 / 803.34 2 2
2 12 2003.12 47 6.27 2768 816 0.99 / 804.16 2 2
3 7 2002.92 24 11.17 3249 871 1.86 / 805.03 2 2
4 13 1908.00 40 11.98 3109 1490 3.35 / 806.52 2 2
5 13 1350.76 40 12.66 2304 1167 4.52 / 807.69 2 2
6 13 425.00 40 13.58 977 531 5.05 / 808.22 2 2
7 8 0.00 165 14.26 300 706 5.75 / 808.92 2 2
Average= 4.82
(KJ/cycle)

Cycle 166 GMT 12/ 6/2021 11:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 27 14.29 442 171 0.17 / 797.77 2 2
2 12 2002.08 47 6.60 2771 860 1.03 / 798.63 2 2
3 7 2001.08 24 11.13 3258 870 1.90 / 799.50 2 2
4 13 1893.36 40 12.00 3094 1485 3.39 / 800.99 2 2
5 13 1221.00 40 12.80 2089 1070 4.46 / 802.05 2 2
6 13 296.12 40 13.76 771 424 4.88 / 802.48 2 2
7 8 0.12 165 14.28 294 693 5.57 / 803.17 2 2
Average= 4.81
(KJ/cycle)

Cycle 165 GMT 2/ 6/2021 12:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 27 14.30 429 166 0.17 / 792.14 2 2
2 12 2002.84 47 6.91 2782 904 1.07 / 793.05 2 2
3 7 2001.52 24 11.16 3226 864 1.93 / 793.91 2 2
4 13 1892.12 40 12.01 3082 1481 3.41 / 795.39 2 2
5 13 1315.36 40 12.68 2244 1138 4.55 / 796.53 2 2
6 13 247.36 40 13.86 690 383 4.93 / 796.91 2 2
7 8 -0.08 165 14.28 292 688 5.62 / 797.60 2 2
Average= 4.80
(KJ/cycle)

Cycle 164 GMT 23/ 5/2021 13: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 27 14.28 449 173 0.17 / 786.60 2 2
2 12 2003.20 47 7.20 2832 958 1.13 / 787.55 2 2
3 7 2001.36 24 11.09 3262 868 2.00 / 788.42 2 2
4 13 1888.40 40 12.01 3074 1477 3.48 / 789.90 2 2
5 13 1161.68 40 12.83 2022 1038 4.51 / 790.94 2 2
6 13 225.36 40 13.89 650 361 4.88 / 791.30 2 2
7 8 0.04 165 14.28 288 679 5.55 / 791.98 2 2
Average= 4.80
(KJ/cycle)

Cycle 163 GMT 13/ 5/2021 13:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 27 14.31 445 172 0.17 / 781.16 2 2
2 12 2003.00 47 7.49 2847 1002 1.17 / 782.17 2 2
3 7 2000.96 24 11.11 3251 867 2.04 / 783.03 2 2
4 13 1883.96 40 11.99 3079 1477 3.52 / 784.51 2 2
5 13 1027.32 40 12.95 1837 952 4.47 / 785.46 2 2
6 13 120.68 40 14.11 482 272 4.74 / 785.73 2 2
7 8 0.08 165 14.30 293 691 5.43 / 786.42 2 2
Average= 4.80
(KJ/cycle)

Cycle 162 GMT 3/ 5/2021 14:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 27 14.32 436 169 0.17 / 775.75 2 2
2 12 2004.48 47 7.49 2844 1001 1.17 / 776.75 2 2
3 7 2002.16 24 11.11 3263 870 2.04 / 777.62 2 2
4 13 1892.28 40 11.98 3102 1486 3.53 / 779.11 2 2
5 13 1014.64 40 12.95 1817 941 4.47 / 780.05 2 2
6 13 108.92 40 14.13 462 261 4.73 / 780.31 2 2
7 8 0.08 165 14.31 289 682 5.41 / 780.99 2 2
Average= 4.79
(KJ/cycle)

Cycle 161 GMT 23/ 4/2021 15:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 27 14.27 449 173 0.17 / 770.20 2 2
2 12 2002.00 47 7.89 2886 1070 1.24 / 771.27 2 2
3 7 1999.00 25 11.14 3240 902 2.15 / 772.17 2 2
4 13 1867.88 40 11.99 3066 1470 3.62 / 773.64 2 2
5 13 1122.36 40 12.87 1959 1008 4.62 / 774.65 2 2
6 13 88.80 40 14.17 430 244 4.87 / 774.89 2 2
7 8 0.04 165 14.29 292 688 5.56 / 775.58 2 2
Average= 4.79
(KJ/cycle)

Cycle 160 GMT 13/ 4/2021 16:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 27 14.34 429 166 0.17 / 764.81 2 2
2 12 2003.16 47 7.97 2879 1078 1.24 / 765.88 2 2
3 7 2000.20 24 11.18 3223 865 2.11 / 766.75 2 2
4 13 1874.12 40 12.01 3059 1470 3.58 / 768.22 2 2
5 13 882.20 40 13.07 1631 853 4.43 / 769.07 2 2
6 13 119.68 40 14.11 479 270 4.70 / 769.34 2 2
7 8 0.04 165 14.29 289 681 5.38 / 770.02 2 2
Average= 4.78
(KJ/cycle)

Cycle 159 GMT 3/ 4/2021 16:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 27 14.32 438 169 0.17 / 759.26 2 2
2 12 2002.04 47 8.22 2938 1135 1.30 / 760.39 2 2
3 7 1999.36 24 11.17 3250 871 2.18 / 761.26 2 2
4 13 1876.72 40 12.00 3058 1468 3.64 / 762.73 2 2
5 13 1106.12 40 12.85 1945 1000 4.64 / 763.73 2 2
6 13 62.00 40 14.22 389 221 4.86 / 763.95 2 2
7 8 0.04 165 14.29 291 686 5.55 / 764.64 2 2
Average= 4.78
(KJ/cycle)

Cycle 158 GMT 24/ 3/2021 17:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 27 14.33 445 172 0.17 / 753.75 2 2
2 12 2007.04 47 8.35 2920 1146 1.32 / 754.90 2 2
3 7 2004.32 24 11.16 3251 871 2.19 / 755.77 2 2
4 13 1883.96 40 11.96 3088 1477 3.67 / 757.24 2 2
5 13 994.04 40 12.96 1786 926 4.59 / 758.17 2 2
6 13 86.92 40 14.18 421 239 4.83 / 758.41 2 2
7 8 0.00 165 14.30 288 680 5.51 / 759.09 2 2
Average= 4.77
(KJ/cycle)

Cycle 157 GMT 14/ 3/2021 18:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 27 14.33 432 167 0.17 / 748.29 2 2
2 12 2004.24 47 8.51 2961 1184 1.35 / 749.47 2 2
3 7 2001.20 24 11.24 3218 868 2.22 / 750.34 2 2
4 13 1872.24 40 11.99 3045 1460 3.68 / 751.80 2 2
5 13 956.56 40 12.99 1729 898 4.58 / 752.70 2 2
6 13 37.64 40 14.28 347 198 4.78 / 752.90 2 2
7 8 0.08 165 14.30 289 682 5.46 / 753.58 2 2
Average= 4.77
(KJ/cycle)

Cycle 156 GMT 4/ 3/2021 19: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 27 14.30 449 173 0.17 / 742.79 2 2
2 12 2003.48 47 8.69 2951 1205 1.38 / 743.99 2 2
3 7 2000.40 24 11.18 3249 872 2.25 / 744.86 2 2
4 13 1872.80 40 11.98 3063 1468 3.72 / 746.33 2 2
5 13 949.56 40 12.99 1722 895 4.61 / 747.23 2 2
6 13 64.04 40 14.22 382 217 4.83 / 747.44 2 2
7 8 0.00 165 14.28 287 676 5.51 / 748.12 2 2
Average= 4.77
(KJ/cycle)

Cycle 155 GMT 22/ 2/2021 20: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 27 14.33 427 165 0.17 / 737.28 2 2
2 12 2005.72 47 8.77 2953 1217 1.38 / 738.50 2 2
3 7 2002.28 24 11.17 3230 866 2.25 / 739.36 2 2
4 13 1870.52 40 11.97 3052 1461 3.71 / 740.83 2 2
5 13 943.52 40 13.01 1705 887 4.60 / 741.71 2 2
6 13 58.60 40 14.22 382 217 4.81 / 741.93 2 2
7 8 -0.04 165 14.28 290 683 5.50 / 742.61 2 2
Average= 4.76
(KJ/cycle)

Cycle 154 GMT 12/ 2/2021 20:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 27 14.31 442 171 0.17 / 731.99 2 2
2 12 2001.04 47 8.94 3005 1263 1.43 / 733.25 2 2
3 7 1996.80 24 11.20 3235 870 2.30 / 734.12 2 2
4 13 1602.80 40 12.29 2669 1312 3.62 / 735.44 2 2
5 13 839.08 40 13.12 1550 813 4.43 / 736.25 2 2
6 13 40.76 40 14.26 350 200 4.63 / 736.45 2 2
7 8 0.00 165 14.29 283 667 5.30 / 737.12 2 2
Average= 4.76
(KJ/cycle)

Cycle 153 GMT 2/ 2/2021 21:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 27 14.32 438 169 0.17 / 726.62 2 2
2 12 2007.32 47 9.09 3016 1289 1.46 / 727.91 2 2
3 7 2004.40 24 11.18 3243 870 2.33 / 728.78 2 2
4 13 1880.04 40 11.97 3061 1466 3.79 / 730.24 2 2
5 13 941.84 40 12.99 1717 892 4.69 / 731.14 2 2
6 8 0.12 165 14.30 290 684 5.37 / 731.82 2 2
Average= 4.75
(KJ/cycle)

Cycle 152 GMT 23/ 1/2021 22:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 27 14.33 429 166 0.17 / 721.20 2 2
2 12 2002.44 47 9.25 3025 1315 1.48 / 722.52 2 2
3 7 1998.76 24 11.17 3253 872 2.35 / 723.39 2 2
4 13 1734.00 40 12.15 2870 1395 3.75 / 724.79 2 2
5 13 809.60 40 13.13 1519 798 4.55 / 725.58 2 2
6 13 32.52 40 14.28 339 194 4.74 / 725.78 2 2
7 8 0.04 165 14.28 286 674 5.41 / 726.45 2 2
Average= 4.75
(KJ/cycle)

Cycle 151 GMT 13/ 1/2021 23: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 27 14.33 427 165 0.17 / 715.95 2 2
2 12 2000.80 47 9.53 3060 1371 1.54 / 717.32 2 2
3 7 1996.48 24 11.17 3252 872 2.41 / 718.19 2 2
4 13 1721.84 40 12.16 2840 1381 3.79 / 719.57 2 2
5 13 809.48 40 13.13 1522 799 4.59 / 720.37 2 2
6 8 0.08 165 14.28 282 664 5.25 / 721.04 2 2
Average= 4.74
(KJ/cycle)

Cycle 150 GMT 3/ 1/2021 23:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 27 14.31 435 168 0.17 / 710.87 2 2
2 12 2002.48 47 9.51 3044 1361 1.53 / 712.23 2 2
3 7 1998.52 24 11.23 3233 871 2.40 / 713.11 2 2
4 13 1603.08 40 12.29 2668 1312 3.71 / 714.42 2 2
5 13 695.76 40 13.25 1350 715 4.43 / 715.13 2 2
6 8 0.08 165 14.28 277 653 5.08 / 715.78 2 2
Average= 4.74
(KJ/cycle)

Cycle 149 GMT 25/12/2020 0:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 27 14.31 438 169 0.17 / 705.64 2 2
2 12 2000.72 47 9.59 3038 1369 1.54 / 707.01 2 2
3 7 1996.68 24 11.23 3218 867 2.41 / 707.88 2 2
4 13 1718.92 40 12.17 2848 1386 3.79 / 709.26 2 2
5 13 771.96 40 13.16 1462 770 4.56 / 710.03 2 2
6 8 0.12 165 14.28 286 674 5.24 / 710.71 2 2
Average= 4.74
(KJ/cycle)

Cycle 148 GMT 15/12/2020 1:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.36 27 14.29 446 172 0.17 / 700.51 2 2
2 12 2002.24 47 9.63 3080 1394 1.57 / 701.90 2 2
3 7 1998.36 24 11.16 3245 869 2.44 / 702.77 2 2
4 13 1595.28 40 12.28 2657 1305 3.74 / 704.08 2 2
5 13 689.08 40 13.25 1355 718 4.46 / 704.79 2 2
6 8 0.16 165 14.26 287 675 5.13 / 705.47 2 2
Average= 4.73
(KJ/cycle)

Cycle 147 GMT 5/12/2020 2:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 27 14.30 431 166 0.17 / 695.37 2 2
2 12 2006.32 47 9.67 3081 1400 1.57 / 696.77 2 2
3 7 2002.80 24 11.24 3241 874 2.44 / 697.65 2 2
4 13 1606.24 40 12.29 2653 1304 3.75 / 698.95 2 2
5 13 687.52 40 13.26 1330 705 4.45 / 699.66 2 2
6 8 0.12 165 14.26 289 680 5.13 / 700.34 2 2
Average= 4.73
(KJ/cycle)

Cycle 146 GMT 25/11/2020 2:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 27 14.34 435 168 0.17 / 690.14 2 2
2 12 2005.20 47 9.79 3082 1418 1.59 / 691.55 2 2
3 7 2001.32 24 11.19 3231 868 2.45 / 692.42 2 2
4 13 1601.88 40 12.28 2677 1315 3.77 / 693.74 2 2
5 13 818.04 40 13.12 1517 796 4.57 / 694.53 2 2
6 8 0.20 165 14.26 286 673 5.24 / 695.21 2 2
Average= 4.73
(KJ/cycle)

Cycle 145 GMT 15/11/2020 3:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 27 14.32 441 171 0.17 / 685.05 2 2
2 12 2002.80 47 9.90 3087 1436 1.61 / 686.49 2 2
3 7 1998.96 24 11.18 3247 871 2.48 / 687.36 2 2
4 13 1600.24 40 12.29 2669 1312 3.79 / 688.67 2 2
5 13 553.56 40 13.39 1166 625 4.41 / 689.29 2 2
6 8 0.16 165 14.27 286 673 5.09 / 689.97 2 2
Average= 4.73
(KJ/cycle)

Cycle 144 GMT 5/11/2020 4:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 27 14.29 450 174 0.17 / 679.72 2 2
2 12 2001.64 47 9.92 3092 1442 1.62 / 681.16 2 2
3 7 1997.28 24 11.18 3235 868 2.48 / 682.03 2 2
4 13 1729.84 40 12.16 2866 1394 3.88 / 683.42 2 2
5 13 785.60 40 13.16 1469 773 4.65 / 684.19 2 2
6 8 0.08 165 14.26 291 685 5.34 / 684.88 2 2
Average= 4.72
(KJ/cycle)

Cycle 143 GMT 26/10/2020 5:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 27 14.29 451 174 0.17 / 674.69 2 2
2 12 2000.00 47 9.80 3124 1439 1.61 / 676.13 2 2
3 7 1995.76 24 11.21 3242 872 2.49 / 677.00 2 2
4 13 1466.20 40 12.45 2444 1217 3.70 / 678.22 2 2
5 13 565.96 40 13.38 1179 631 4.33 / 678.85 2 2
6 8 0.04 165 14.24 294 691 5.02 / 679.54 2 2
Average= 4.72
(KJ/cycle)

Cycle 142 GMT 16/10/2020 5:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 27 14.30 451 174 0.17 / 669.67 2 2
2 12 2004.32 47 10.10 3126 1484 1.66 / 671.15 2 2
3 7 2000.28 24 11.24 3227 871 2.53 / 672.02 2 2
4 13 1453.28 40 12.45 2439 1215 3.74 / 673.24 2 2
5 13 541.44 40 13.42 1123 603 4.35 / 673.84 2 2
6 8 0.08 165 14.25 289 680 5.03 / 674.52 2 2
Average= 4.72
(KJ/cycle)

Cycle 141 GMT 6/10/2020 6:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 27 14.30 442 171 0.17 / 664.26 2 2
2 12 2000.96 47 10.06 3106 1469 1.64 / 665.72 2 2
3 7 1996.64 24 11.19 3229 867 2.51 / 666.59 2 2
4 13 1583.76 40 12.30 2640 1299 3.81 / 667.89 2 2
5 13 656.52 40 13.28 1298 689 4.49 / 668.58 2 2
6 13 81.48 40 14.17 415 235 4.73 / 668.81 2 2
7 8 0.08 165 14.24 289 679 5.41 / 669.49 2 2
Average= 4.71
(KJ/cycle)

Cycle 140 GMT 26/ 9/2020 7: 3:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 27 14.31 437 169 0.17 / 659.17 2 2
2 12 2003.96 47 10.10 3110 1476 1.65 / 660.64 2 2
3 7 1999.64 24 11.23 3219 868 2.51 / 661.51 2 2
4 13 1593.12 40 12.30 2655 1306 3.82 / 662.82 2 2
5 13 534.44 40 13.44 1105 594 4.41 / 663.41 2 2
6 8 0.12 165 14.24 287 674 5.09 / 664.08 2 2
Average= 4.71
(KJ/cycle)

Cycle 139 GMT 16/ 9/2020 7:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 27 14.31 439 170 0.17 / 653.78 2 2
2 12 2005.44 47 10.15 3110 1484 1.65 / 655.26 2 2
3 7 2001.24 24 11.24 3215 867 2.52 / 656.13 2 2
4 13 1591.24 40 12.32 2654 1308 3.83 / 657.44 2 2
5 13 667.44 40 13.27 1314 697 4.53 / 658.14 2 2
6 8 0.12 165 14.24 288 677 5.20 / 658.81 2 2
7 14 0.12 45 14.27 289 186 5.39 / 659.00 2 2
Average= 4.71
(KJ/cycle)

Cycle 138 GMT 6/ 9/2020 8:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 27 14.29 435 168 0.17 / 648.50 2 2
2 12 2003.04 47 10.11 3111 1478 1.65 / 649.97 2 2
3 7 1998.84 24 11.22 3221 867 2.51 / 650.84 2 2
4 13 1451.96 40 12.45 2430 1210 3.72 / 652.05 2 2
5 13 670.44 40 13.28 1304 693 4.42 / 652.74 2 2
6 13 27.00 40 14.26 329 188 4.60 / 652.93 2 2
7 8 0.20 165 14.21 289 678 5.28 / 653.61 2 2
Average= 4.70
(KJ/cycle)

Cycle 137 GMT 27/ 8/2020 9:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 27 14.30 448 173 0.17 / 643.39 2 2
2 12 2003.64 47 10.21 3131 1502 1.68 / 644.89 2 2
3 7 1999.40 24 11.27 3214 869 2.54 / 645.76 2 2
4 13 1444.64 40 12.48 2409 1203 3.75 / 646.97 2 2
5 13 669.92 40 13.28 1310 696 4.44 / 647.66 2 2
6 8 0.04 165 14.23 284 667 5.11 / 648.33 2 2
Average= 4.70
(KJ/cycle)

Cycle 136 GMT 17/ 8/2020 10: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.56 27 14.33 448 173 0.17 / 638.23 2 2
2 12 2000.36 47 10.31 3118 1511 1.68 / 639.74 2 2
3 7 1996.00 24 11.24 3199 863 2.55 / 640.60 2 2
4 13 1561.40 40 12.35 2597 1283 3.83 / 641.88 2 2
5 13 623.44 40 13.33 1240 661 4.49 / 642.55 2 2
6 8 0.08 165 14.23 286 672 5.16 / 643.22 2 2
Average= 4.70
(KJ/cycle)

Cycle 135 GMT 7/ 8/2020 11:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 27 14.29 446 172 0.17 / 632.95 2 2
2 12 2000.60 47 10.25 3121 1504 1.68 / 634.45 2 2
3 7 1996.08 24 11.24 3218 868 2.54 / 635.32 2 2
4 13 1717.72 40 12.19 2850 1390 3.93 / 636.71 2 2
5 13 621.56 40 13.33 1250 666 4.60 / 637.37 2 2
6 8 0.04 165 14.23 290 681 5.28 / 638.05 2 2
Average= 4.69
(KJ/cycle)

Cycle 134 GMT 28/ 7/2020 12:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 27 14.35 440 170 0.17 / 627.44 2 2
2 12 1999.32 47 10.30 3144 1522 1.69 / 628.97 2 2
3 7 1994.60 24 11.28 3217 871 2.56 / 629.84 2 2
4 13 1571.80 40 12.36 2613 1292 3.86 / 631.13 2 2
5 13 773.68 40 13.16 1469 773 4.63 / 631.90 2 2
6 8 0.20 165 14.24 291 684 5.31 / 632.59 2 2
7 14 0.20 45 14.25 293 188 5.50 / 632.77 2 2
Average= 4.69
(KJ/cycle)

Cycle 133 GMT 18/ 7/2020 13: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 27 14.33 448 173 0.17 / 622.37 2 2
2 12 1999.16 45 10.36 3106 1448 1.62 / 623.81 2 2
3 7 1994.56 24 11.29 3222 873 2.49 / 624.69 2 2
4 13 1582.32 40 12.34 2632 1299 3.79 / 625.99 2 2
5 13 527.88 40 13.44 1114 599 4.39 / 626.59 2 2
6 8 0.08 165 14.24 293 688 5.08 / 627.27 2 2
Average= 4.68
(KJ/cycle)

Cycle 132 GMT 8/ 7/2020 13:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.32 27 14.35 427 165 0.17 / 617.20 2 2
2 12 2003.72 45 10.29 3143 1455 1.62 / 618.65 2 2
3 7 1999.64 24 11.31 3235 878 2.50 / 619.53 2 2
4 13 1589.28 40 12.34 2655 1311 3.81 / 620.84 2 2
5 13 638.48 40 13.32 1268 676 4.49 / 621.52 2 2
6 8 0.04 165 14.23 288 676 5.16 / 622.19 2 2
Average= 4.68
(KJ/cycle)

Cycle 131 GMT 28/ 6/2020 14:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 27 14.33 451 174 0.17 / 611.80 2 2
2 12 2001.84 45 10.36 3131 1460 1.63 / 613.26 2 2
3 7 1997.32 25 11.30 3217 909 2.54 / 614.17 2 2
4 13 1582.28 40 12.34 2654 1310 3.85 / 615.48 2 2
5 13 633.12 40 13.33 1260 672 4.52 / 616.15 2 2
6 13 59.20 40 14.20 379 215 4.74 / 616.37 2 2
7 8 -0.04 165 14.24 282 663 5.40 / 617.03 2 2
Average= 4.67
(KJ/cycle)

Cycle 130 GMT 18/ 6/2020 15:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 27 14.33 442 171 0.17 / 606.55 2 2
2 12 2000.08 45 10.41 3129 1466 1.64 / 608.01 2 2
3 7 1995.44 24 11.33 3222 876 2.51 / 608.89 2 2
4 13 1719.32 40 12.21 2845 1389 3.90 / 610.28 2 2
5 13 641.72 40 13.32 1271 677 4.58 / 610.96 2 2
6 8 0.08 165 14.24 286 672 5.25 / 611.63 2 2
Average= 4.67
(KJ/cycle)

Cycle 129 GMT 8/ 6/2020 16:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.84 27 14.33 441 171 0.17 / 601.18 2 2
2 12 2006.48 45 10.41 3131 1467 1.64 / 602.64 2 2
3 7 2002.28 24 11.27 3231 874 2.51 / 603.52 2 2
4 13 1599.60 40 12.33 2670 1317 3.83 / 604.83 2 2
5 13 659.40 40 13.31 1294 689 4.52 / 605.52 2 2
6 8 0.08 165 14.25 286 672 5.19 / 606.19 2 2
7 14 0.08 45 14.27 286 184 5.37 / 606.38 2 2
Average= 4.66
(KJ/cycle)

Cycle 128 GMT 29/ 5/2020 16:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 27 14.35 439 170 0.17 / 595.93 2 2
2 12 2002.96 45 10.41 3124 1463 1.63 / 597.39 2 2
3 7 1998.40 24 11.34 3210 874 2.51 / 598.27 2 2
4 13 1718.60 40 12.21 2838 1386 3.89 / 599.65 2 2
5 13 640.80 40 13.33 1271 678 4.57 / 600.33 2 2
6 8 0.12 165 14.23 287 674 5.24 / 601.00 2 2
Average= 4.66
(KJ/cycle)

Cycle 127 GMT 19/ 5/2020 17:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.96 27 14.36 433 168 0.17 / 590.79 2 2
2 12 2000.56 45 10.47 3127 1473 1.64 / 592.26 2 2
3 7 1996.32 24 11.30 3220 873 2.51 / 593.13 2 2
4 13 1572.00 40 12.36 2635 1303 3.82 / 594.43 2 2
5 13 632.16 40 13.34 1253 669 4.49 / 595.10 2 2
6 8 0.12 165 14.26 279 656 5.14 / 595.76 2 2
Average= 4.65
(KJ/cycle)

Cycle 126 GMT 9/ 5/2020 18:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 27 14.36 437 169 0.17 / 585.60 2 2
2 12 2001.80 45 10.40 3127 1463 1.63 / 587.07 2 2
3 7 1997.68 24 11.35 3241 883 2.52 / 587.95 2 2
4 13 1591.88 40 12.35 2646 1307 3.82 / 589.26 2 2
5 13 651.16 40 13.31 1291 687 4.51 / 589.94 2 2
6 8 0.00 165 14.26 286 673 5.18 / 590.62 2 2
Average= 4.65
(KJ/cycle)

Cycle 125 GMT 29/ 4/2020 19:20: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 27 14.33 449 174 0.17 / 580.48 2 2
2 12 2001.00 45 10.68 2880 1384 1.56 / 581.86 2 2
3 7 1997.16 24 11.32 3230 878 2.44 / 582.74 2 2
4 13 1593.92 40 12.35 2658 1313 3.75 / 584.06 2 2
5 13 679.76 40 13.29 1329 706 4.45 / 584.76 2 2
6 8 0.12 165 14.25 286 672 5.13 / 585.43 2 2
Average= 4.65
(KJ/cycle)

Cycle 124 GMT 19/ 4/2020 20:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 27 14.38 435 169 0.17 / 575.28 2 2
2 12 2002.88 45 10.45 3150 1481 1.65 / 576.77 2 2
3 7 1998.68 24 11.34 3247 884 2.53 / 577.65 2 2
4 13 1587.04 40 12.36 2651 1311 3.84 / 578.96 2 2
5 13 637.84 40 13.34 1263 674 4.52 / 579.63 2 2
6 8 0.12 165 14.26 286 673 5.19 / 580.31 2 2
Average= 4.64
(KJ/cycle)

Cycle 123 GMT 9/ 4/2020 20:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 27 14.39 428 166 0.17 / 570.25 2 2
2 12 2002.44 45 10.59 3145 1499 1.67 / 571.75 2 2
3 7 1998.08 24 11.37 3216 878 2.54 / 572.63 2 2
4 13 1451.28 40 12.50 2435 1217 3.76 / 573.84 2 2
5 13 522.88 40 13.46 1102 593 4.35 / 574.44 2 2
6 8 0.08 165 14.24 289 679 5.03 / 575.12 2 2
Average= 4.64
(KJ/cycle)

Cycle 122 GMT 30/ 3/2020 21:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 27 14.37 437 170 0.17 / 565.23 2 2
2 12 2001.12 45 10.53 3135 1486 1.66 / 566.71 2 2
3 7 1997.04 24 11.35 3233 881 2.54 / 567.59 2 2
4 13 1445.16 40 12.51 2418 1210 3.75 / 568.80 2 2
5 13 556.72 40 13.43 1144 615 4.36 / 569.42 2 2
6 8 0.24 165 14.24 284 667 5.03 / 570.08 2 2
Average= 4.63
(KJ/cycle)

Cycle 121 GMT 20/ 3/2020 22:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 27 14.40 437 170 0.17 / 560.21 2 2
2 12 2003.24 45 10.47 3148 1483 1.65 / 561.69 2 2
3 7 1998.64 24 11.36 3232 881 2.53 / 562.58 2 2
4 13 1458.48 40 12.51 2438 1220 3.75 / 563.80 2 2
5 13 529.44 40 13.47 1108 597 4.35 / 564.39 2 2
6 8 0.00 165 14.25 282 663 5.01 / 565.06 2 2
Average= 4.63
(KJ/cycle)

Cycle 120 GMT 10/ 3/2020 23: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 27 14.38 447 174 0.17 / 555.20 2 2
2 12 2002.32 42 10.46 3141 1380 1.55 / 556.58 2 2
3 7 1997.92 24 11.40 3182 871 2.42 / 557.45 2 2
4 13 1587.00 38 12.42 2635 1244 3.67 / 558.69 2 2
5 13 683.24 38 13.31 1337 676 4.34 / 559.37 2 2
6 8 0.20 165 14.27 287 676 5.02 / 560.04 2 2
Average= 4.63
(KJ/cycle)

Cycle 119 GMT 29/ 2/2020 23:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 27 14.38 421 163 0.16 / 549.82 2 2
2 12 2001.88 42 10.49 3115 1372 1.54 / 551.19 2 2
3 7 1997.44 24 11.39 3226 882 2.42 / 552.08 2 2
4 13 1727.92 38 12.25 2873 1337 3.76 / 553.41 2 2
5 13 782.32 38 13.22 1476 741 4.50 / 554.16 2 2
6 13 26.56 38 14.30 333 181 4.68 / 554.34 2 2
7 8 0.00 165 14.23 292 686 5.36 / 555.02 2 2
Average= 4.63
(KJ/cycle)

Cycle 118 GMT 20/ 2/2020 0:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 27 14.40 435 169 0.17 / 544.87 2 2
2 12 2002.44 42 10.51 3105 1371 1.54 / 546.24 2 2
3 7 1998.32 24 11.40 3230 884 2.42 / 547.12 2 2
4 13 1577.40 38 12.44 2615 1236 3.66 / 548.36 2 2
5 13 679.60 38 13.33 1319 668 4.33 / 549.03 2 2
6 8 0.12 165 14.31 267 630 4.96 / 549.66 2 2
Average= 4.62
(KJ/cycle)

Cycle 117 GMT 10/ 2/2020 1: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 27 14.39 431 167 0.17 / 539.40 2 2
2 12 2002.52 42 10.51 3124 1379 1.55 / 540.78 2 2
3 7 1998.20 24 11.38 3220 879 2.43 / 541.66 2 2
4 13 1736.12 37 12.27 2856 1297 3.72 / 542.96 2 2
5 13 1079.40 37 12.93 1907 912 4.63 / 543.87 2 2
6 13 22.76 37 14.34 315 167 4.80 / 544.04 2 2
7 8 0.00 165 14.27 282 664 5.47 / 544.70 2 2
Average= 4.62
(KJ/cycle)

Cycle 116 GMT 31/ 1/2020 1:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 27 14.39 434 169 0.17 / 534.15 2 2
2 12 2001.56 42 10.69 3125 1403 1.57 / 535.56 2 2
3 7 1997.04 24 11.40 3234 885 2.46 / 536.44 2 2
4 13 1578.48 37 12.44 2622 1207 3.66 / 537.65 2 2
5 13 796.88 37 13.21 1493 730 4.39 / 538.38 2 2
6 13 56.88 37 14.24 372 196 4.59 / 538.57 2 2
7 8 0.04 165 14.25 281 661 5.25 / 539.23 2 2
Average= 4.61
(KJ/cycle)

Cycle 115 GMT 21/ 1/2020 2:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.64 27 14.42 426 166 0.17 / 529.17 2 2
2 12 2005.16 42 10.52 3121 1379 1.54 / 530.54 2 2
3 7 2001.36 24 11.39 3245 887 2.43 / 531.43 2 2
4 13 1464.12 37 12.55 2460 1142 3.57 / 532.57 2 2
5 13 588.72 37 13.44 1183 588 4.16 / 533.16 2 2
6 13 24.44 37 14.33 316 168 4.33 / 533.33 2 2
7 8 0.08 165 14.27 278 655 4.98 / 533.98 2 2
Average= 4.60
(KJ/cycle)

Cycle 114 GMT 11/ 1/2020 3: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 27 14.40 438 170 0.17 / 524.26 2 2
2 12 2004.28 40 10.55 3128 1320 1.49 / 525.58 2 2
3 7 2000.48 24 11.47 3220 886 2.38 / 526.47 2 2
4 13 1570.68 37 12.44 2636 1213 3.59 / 527.68 2 2
5 13 682.68 37 13.34 1326 654 4.24 / 528.34 2 2
6 8 0.12 165 14.29 281 663 4.91 / 529.00 2 2
Average= 4.60
(KJ/cycle)

Cycle 113 GMT 1/ 1/2020 3:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 27 14.39 432 168 0.17 / 519.22 2 2
2 12 2001.72 40 10.54 3129 1319 1.49 / 520.54 2 2
3 7 1997.24 24 11.43 3225 885 2.37 / 521.42 2 2
4 13 1716.16 37 12.30 2840 1292 3.66 / 522.71 2 2
5 13 770.52 37 13.24 1462 716 4.38 / 523.43 2 2
6 8 0.12 165 14.28 282 664 5.04 / 524.09 2 2
Average= 4.60
(KJ/cycle)

Cycle 112 GMT 22/12/2019 4:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 27 14.41 438 170 0.17 / 514.22 2 2
2 12 2000.28 40 10.54 3128 1319 1.49 / 515.54 2 2
3 7 1996.08 24 11.43 3222 884 2.37 / 516.42 2 2
4 13 1731.08 37 12.26 2874 1304 3.68 / 517.72 2 2
5 13 674.36 37 13.32 1336 658 4.34 / 518.38 2 2
6 8 0.08 165 14.29 282 665 5.00 / 519.05 2 2
Average= 4.59
(KJ/cycle)

Cycle 111 GMT 12/12/2019 4:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 27 14.40 436 170 0.17 / 509.33 2 2
2 12 2003.72 40 10.64 3107 1322 1.49 / 510.65 2 2
3 7 1999.72 24 11.48 3225 889 2.38 / 511.54 2 2
4 13 1471.72 37 12.53 2490 1154 3.53 / 512.69 2 2
5 13 722.04 37 13.29 1391 684 4.22 / 513.38 2 2
6 8 0.16 165 14.28 284 669 4.89 / 514.05 2 2
Average= 4.59
(KJ/cycle)

Cycle 110 GMT 2/12/2019 5:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 27 14.41 431 168 0.17 / 504.26 2 2
2 12 2000.44 40 10.61 3135 1330 1.50 / 505.59 2 2
3 7 1996.16 24 11.45 3221 885 2.38 / 506.48 2 2
4 13 1718.68 37 12.28 2847 1294 3.68 / 507.77 2 2
5 13 777.96 37 13.22 1481 724 4.40 / 508.50 2 2
6 8 0.12 165 14.28 282 664 5.07 / 509.16 2 2
Average= 4.59
(KJ/cycle)

Cycle 109 GMT 22/11/2019 6:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 27 14.40 432 168 0.17 / 499.47 2 2
2 12 2000.84 40 10.59 3108 1317 1.48 / 500.79 2 2
3 7 1996.64 24 11.48 3230 890 2.37 / 501.68 2 2
4 13 1462.08 37 12.56 2457 1142 3.52 / 502.82 2 2
5 13 590.12 37 13.44 1204 599 4.11 / 503.42 2 2
6 8 0.12 165 14.27 287 676 4.79 / 504.09 2 2
Average= 4.58
(KJ/cycle)

Cycle 108 GMT 12/11/2019 6:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 27 14.44 433 169 0.17 / 494.46 2 2
2 12 2000.80 40 10.62 3128 1329 1.50 / 495.79 2 2
3 7 1996.40 24 11.50 3227 891 2.39 / 496.68 2 2
4 13 1577.24 37 12.44 2642 1216 3.60 / 497.90 2 2
5 13 808.52 37 13.21 1518 742 4.35 / 498.64 2 2
6 8 0.08 165 14.26 282 664 5.01 / 499.30 2 2
Average= 4.58
(KJ/cycle)

Cycle 107 GMT 2/11/2019 7:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 27 14.42 434 169 0.17 / 489.48 2 2
2 12 2000.56 40 10.63 3110 1322 1.49 / 490.80 2 2
3 7 1996.28 24 11.46 3219 885 2.38 / 491.69 2 2
4 13 1726.84 37 12.30 2845 1295 3.67 / 492.98 2 2
5 13 660.28 37 13.36 1302 644 4.32 / 493.63 2 2
6 8 0.12 165 14.28 283 667 4.98 / 494.29 2 2
Average= 4.58
(KJ/cycle)

Cycle 106 GMT 23/10/2019 7:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 27 14.40 433 168 0.17 / 484.45 2 2
2 12 1999.68 40 10.66 3119 1330 1.50 / 485.78 2 2
3 7 1995.44 24 11.50 3226 890 2.39 / 486.67 2 2
4 13 1588.72 37 12.42 2658 1221 3.61 / 487.89 2 2
5 13 822.76 37 13.20 1526 745 4.36 / 488.63 2 2
6 8 0.08 165 14.26 288 678 5.03 / 489.31 2 2
Average= 4.57
(KJ/cycle)

Cycle 105 GMT 13/10/2019 8:42: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 27 14.42 434 169 0.17 / 479.52 2 2
2 12 1999.52 40 10.72 3135 1344 1.51 / 480.86 2 2
3 7 1994.80 24 11.53 3228 893 2.41 / 481.76 2 2
4 13 1570.52 37 12.47 2620 1209 3.62 / 482.96 2 2
5 13 666.80 37 13.36 1309 647 4.26 / 483.61 2 2
6 8 0.08 165 14.25 284 668 4.93 / 484.28 2 2
Average= 4.57
(KJ/cycle)

Cycle 104 GMT 3/10/2019 9:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 27 14.41 424 165 0.16 / 474.51 2 2
2 12 2001.40 40 10.65 3135 1336 1.50 / 475.85 2 2
3 7 1997.16 24 11.52 3232 894 2.39 / 476.74 2 2
4 13 1716.40 37 12.33 2821 1287 3.68 / 478.03 2 2
5 13 675.08 37 13.36 1317 651 4.33 / 478.68 2 2
6 8 0.12 165 14.25 285 670 5.00 / 479.35 2 2
Average= 4.57
(KJ/cycle)

Cycle 103 GMT 23/ 9/2019 10: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 27 14.37 446 173 0.17 / 469.61 2 2
2 12 2002.56 40 10.70 3150 1348 1.52 / 470.96 2 2
3 7 1998.36 25 11.55 3233 934 2.45 / 471.89 2 2
4 13 1455.80 37 12.59 2432 1133 3.59 / 473.02 2 2
5 13 695.96 37 13.35 1342 663 4.25 / 473.69 2 2
6 8 0.00 165 14.26 280 659 4.91 / 474.35 2 2
Average= 4.56
(KJ/cycle)

Cycle 102 GMT 13/ 9/2019 10:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 27 14.38 430 167 0.17 / 464.59 2 2
2 12 2003.28 40 10.70 3118 1335 1.50 / 465.92 2 2
3 7 1999.08 24 11.51 3211 887 2.39 / 466.81 2 2
4 13 1452.92 37 12.59 2433 1133 3.52 / 467.94 2 2
5 13 694.24 37 13.35 1346 665 4.19 / 468.61 2 2
6 13 19.44 37 14.34 315 167 4.35 / 468.77 2 2
7 8 0.04 165 14.21 283 664 5.02 / 469.44 2 2
Average= 4.56
(KJ/cycle)

Cycle 101 GMT 3/ 9/2019 11:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.04 27 14.40 443 172 0.17 / 459.55 2 2
2 12 2001.36 40 10.74 3148 1352 1.52 / 460.91 2 2
3 7 1997.12 24 11.59 3226 897 2.42 / 461.80 2 2
4 13 1583.68 37 12.47 2638 1217 3.64 / 463.02 2 2
5 13 801.56 37 13.24 1512 741 4.38 / 463.76 2 2
6 8 0.12 165 14.26 280 659 5.04 / 464.42 2 2
Average= 4.55
(KJ/cycle)

Cycle 100 GMT 24/ 8/2019 12: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 27 14.45 424 165 0.17 / 454.67 2 2
2 12 2002.76 40 10.70 3148 1347 1.51 / 456.02 2 2
3 7 1998.64 24 11.56 3231 896 2.41 / 456.91 2 2
4 13 1583.88 37 12.47 2642 1219 3.63 / 458.13 2 2
5 13 566.64 37 13.49 1170 584 4.21 / 458.72 2 2
6 8 0.08 165 14.26 283 666 4.88 / 459.38 2 2
Average= 4.55
(KJ/cycle)

Cycle 99 GMT 14/ 8/2019 12:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 27 14.38 448 174 0.17 / 449.74 2 2
2 12 2003.72 40 10.87 3111 1353 1.53 / 451.09 2 2
3 7 1999.88 24 11.61 3214 896 2.42 / 451.98 2 2
4 13 1581.20 37 12.48 2636 1217 3.64 / 453.20 2 2
5 13 668.68 37 13.38 1308 648 4.29 / 453.85 2 2
6 8 0.04 165 14.28 278 655 4.94 / 454.50 2 2
Average= 4.55
(KJ/cycle)

Cycle 98 GMT 4/ 8/2019 13:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 27 14.43 431 168 0.17 / 444.83 2 2
2 12 2009.08 40 10.85 3140 1363 1.53 / 446.19 2 2
3 7 2005.36 24 11.59 3225 897 2.43 / 447.09 2 2
4 13 1451.24 37 12.63 2428 1135 3.56 / 448.22 2 2
5 13 442.28 37 13.65 978 494 4.06 / 448.72 2 2
6 13 27.60 37 14.32 329 174 4.23 / 448.89 2 2
7 8 -0.08 165 14.23 286 672 4.90 / 449.56 2 2
Average= 4.54
(KJ/cycle)

Cycle 97 GMT 25/ 7/2019 13:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 27 14.43 428 167 0.17 / 439.98 2 2
2 12 2001.32 40 10.84 3107 1347 1.51 / 441.32 2 2
3 7 1996.76 24 11.62 3227 900 2.41 / 442.22 2 2
4 13 1587.92 37 12.50 2633 1218 3.63 / 443.44 2 2
5 13 555.12 37 13.51 1142 571 4.20 / 444.01 2 2
6 8 0.08 165 14.28 274 646 4.85 / 444.66 2 2
Average= 4.54
(KJ/cycle)

Cycle 96 GMT 15/ 7/2019 13:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 27 14.44 424 165 0.17 / 435.14 2 2
2 12 2000.80 40 10.76 3129 1347 1.51 / 436.49 2 2
3 7 1995.96 24 11.63 3174 886 2.40 / 437.38 2 2
4 13 1579.68 37 12.52 2615 1211 3.61 / 438.59 2 2
5 13 544.92 37 13.54 1129 566 4.17 / 439.15 2 2
6 8 0.00 165 14.26 279 656 4.83 / 439.81 2 2
Average= 4.53
(KJ/cycle)

Cycle 95 GMT 5/ 7/2019 14:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 27 14.45 422 165 0.16 / 430.36 2 2
2 12 2014.80 40 10.82 3117 1349 1.51 / 431.71 2 2
3 7 2011.16 24 11.61 3235 901 2.42 / 432.61 2 2
4 13 1476.00 37 12.63 2456 1148 3.56 / 433.76 2 2
5 13 568.68 37 13.53 1157 579 4.14 / 434.34 2 2
6 8 0.00 165 14.30 272 642 4.78 / 434.98 2 2
Average= 4.53
(KJ/cycle)

Cycle 94 GMT 25/ 6/2019 14:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.40 27 14.46 423 165 0.17 / 425.39 2 2
2 12 2004.16 40 10.84 3113 1350 1.51 / 426.74 2 2
3 7 2000.40 24 11.69 3195 896 2.41 / 427.64 2 2
4 13 1446.24 37 12.68 2420 1135 3.55 / 428.78 2 2
5 13 566.28 37 13.54 1153 578 4.12 / 429.35 2 2
6 13 56.16 37 14.31 362 192 4.32 / 429.55 2 2
7 8 0.00 165 14.28 276 650 4.97 / 430.20 2 2
Average= 4.53
(KJ/cycle)

Cycle 93 GMT 15/ 6/2019 15: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 27 14.43 444 173 0.17 / 420.39 2 2
2 12 2007.20 40 10.71 3131 1341 1.51 / 421.73 2 2
3 7 2003.28 24 11.62 3234 902 2.42 / 422.64 2 2
4 13 1732.64 37 12.41 2840 1304 3.72 / 423.94 2 2
5 13 644.92 37 13.45 1269 632 4.35 / 424.57 2 2
6 8 0.04 165 14.29 279 658 5.01 / 425.23 2 2
Average= 4.52
(KJ/cycle)

Cycle 92 GMT 5/ 6/2019 15:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 27 14.44 428 167 0.17 / 415.46 2 2
2 12 2000.36 40 10.87 3070 1335 1.50 / 416.80 2 2
3 7 1996.08 24 11.63 3222 899 2.40 / 417.70 2 2
4 13 1565.16 37 12.57 2603 1211 3.61 / 418.91 2 2
5 13 659.36 37 13.45 1295 644 4.26 / 419.55 2 2
6 8 0.04 165 14.28 284 669 4.93 / 420.22 2 2
Average= 4.52
(KJ/cycle)

Cycle 91 GMT 26/ 5/2019 16: 7: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 26 14.47 430 162 0.16 / 410.37 2 2
2 12 2003.88 40 10.81 3152 1363 1.52 / 411.73 2 2
3 7 1999.68 24 11.69 3246 911 2.44 / 412.64 2 2
4 13 1588.84 37 12.58 2650 1233 3.67 / 413.87 2 2
5 13 812.64 37 13.31 1521 749 4.42 / 414.62 2 2
6 8 0.12 165 14.29 285 672 5.09 / 415.29 2 2
Average= 4.51
(KJ/cycle)

Cycle 90 GMT 16/ 5/2019 16:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 26 14.49 423 159 0.16 / 405.48 2 2
2 12 2005.20 38 10.77 3101 1269 1.43 / 406.75 2 2
3 7 2001.48 24 11.70 3207 901 2.33 / 407.65 2 2
4 13 1600.12 37 12.58 2651 1234 3.56 / 408.89 2 2
5 13 690.88 37 13.44 1344 668 4.23 / 409.55 2 2
6 8 0.08 165 14.30 276 651 4.88 / 410.20 2 2
Average= 4.51
(KJ/cycle)

Cycle 89 GMT 6/ 5/2019 17:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 26 14.47 432 163 0.16 / 400.61 2 2
2 12 2002.88 38 10.67 3117 1264 1.43 / 401.87 2 2
3 7 1999.24 24 11.62 3229 901 2.33 / 402.77 2 2
4 13 1599.24 37 12.57 2658 1236 3.56 / 404.01 2 2
5 13 684.56 37 13.45 1325 659 4.22 / 404.67 2 2
6 8 0.16 165 14.29 278 655 4.88 / 405.32 2 2
Average= 4.50
(KJ/cycle)

Cycle 88 GMT 26/ 4/2019 18: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 26 14.49 431 162 0.16 / 395.71 2 2
2 12 2000.40 38 10.68 3128 1269 1.43 / 396.98 2 2
3 7 1996.40 24 11.68 3199 897 2.33 / 397.87 2 2
4 13 1593.68 37 12.61 2624 1224 3.55 / 399.10 2 2
5 13 705.36 37 13.44 1357 675 4.23 / 399.77 2 2
6 8 0.08 165 14.31 284 671 4.90 / 400.44 2 2
Average= 4.50
(KJ/cycle)

Cycle 87 GMT 16/ 4/2019 18:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 26 14.48 427 161 0.16 / 390.82 2 2
2 12 2000.96 38 10.71 3141 1278 1.44 / 392.10 2 2
3 7 1996.40 24 11.70 3213 902 2.34 / 393.00 2 2
4 13 1573.76 37 12.63 2639 1233 3.57 / 394.23 2 2
5 13 667.20 37 13.48 1307 652 4.23 / 394.88 2 2
6 8 0.16 165 14.30 281 663 4.89 / 395.55 2 2
Average= 4.49
(KJ/cycle)

Cycle 86 GMT 6/ 4/2019 19:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 26 14.48 431 162 0.16 / 386.01 2 2
2 12 2000.80 38 10.74 3113 1270 1.43 / 387.28 2 2
3 7 1996.56 24 11.74 3231 910 2.34 / 388.19 2 2
4 13 1575.60 37 12.64 2628 1229 3.57 / 389.42 2 2
5 13 540.24 37 13.62 1123 566 4.14 / 389.99 2 2
6 8 0.08 165 14.32 283 669 4.81 / 390.66 2 2
Average= 4.49
(KJ/cycle)

Cycle 85 GMT 27/ 3/2019 19:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 26 14.52 434 164 0.16 / 380.84 2 2
2 12 2000.00 38 10.69 3124 1269 1.43 / 382.11 2 2
3 7 1995.96 24 11.70 3219 904 2.34 / 383.01 2 2
4 13 1718.52 37 12.51 2852 1320 3.66 / 384.33 2 2
5 13 670.28 37 13.49 1319 658 4.32 / 384.99 2 2
6 13 34.00 37 14.37 341 181 4.50 / 385.17 2 2
7 8 0.04 165 14.26 288 678 5.17 / 385.85 2 2
Average= 4.49
(KJ/cycle)

Cycle 84 GMT 17/ 3/2019 20:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 26 14.51 432 163 0.16 / 375.92 2 2
2 12 2003.52 38 10.89 3126 1294 1.46 / 377.21 2 2
3 7 1999.68 24 11.68 3231 906 2.36 / 378.12 2 2
4 13 1585.08 37 12.67 2604 1221 3.58 / 379.34 2 2
5 13 679.88 37 13.49 1336 667 4.25 / 380.01 2 2
6 8 0.08 165 14.32 283 669 4.92 / 380.68 2 2
Average= 4.48
(KJ/cycle)

Cycle 83 GMT 7/ 3/2019 20:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.04 26 14.49 434 164 0.16 / 371.20 2 2
2 12 2003.36 38 10.95 3127 1301 1.46 / 372.50 2 2
3 7 1999.16 24 11.74 3221 908 2.37 / 373.41 2 2
4 13 1466.96 35 12.80 2473 1108 3.48 / 374.51 2 2
5 13 590.48 35 13.61 1203 573 4.05 / 375.09 2 2
6 8 0.16 165 14.31 284 671 4.72 / 375.76 2 2
Average= 4.47
(KJ/cycle)

Cycle 82 GMT 25/ 2/2019 20:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.92 26 14.50 429 162 0.16 / 366.24 2 2
2 12 2003.20 38 10.90 3122 1293 1.45 / 367.53 2 2
3 7 1999.08 24 11.77 3234 914 2.37 / 368.45 2 2
4 13 1460.12 35 12.82 2445 1097 3.47 / 369.54 2 2
5 13 699.88 35 13.51 1362 644 4.11 / 370.19 2 2
6 13 23.08 35 14.39 330 166 4.28 / 370.35 2 2
7 8 0.04 165 14.27 289 680 4.96 / 371.03 2 2
Average= 4.47
(KJ/cycle)

Cycle 81 GMT 15/ 2/2019 21: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 26 14.51 433 163 0.16 / 361.26 2 2
2 12 2002.40 38 10.91 3129 1297 1.46 / 362.56 2 2
3 7 1998.48 24 11.82 3171 900 2.36 / 363.45 2 2
4 13 1570.32 35 12.75 2607 1163 3.52 / 364.62 2 2
5 13 665.16 35 13.55 1305 619 4.14 / 365.24 2 2
6 13 35.52 35 14.37 341 172 4.31 / 365.41 2 2
7 8 0.04 165 14.27 284 669 4.98 / 366.08 2 2
Average= 4.46
(KJ/cycle)

Cycle 80 GMT 5/ 2/2019 21:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 26 14.50 434 164 0.16 / 356.13 2 2
2 12 2001.32 38 10.95 3114 1296 1.46 / 357.42 2 2
3 7 1996.84 24 11.80 3234 916 2.38 / 358.34 2 2
4 13 1722.76 35 12.62 2812 1242 3.62 / 359.58 2 2
5 13 776.36 35 13.45 1466 690 4.31 / 360.27 2 2
6 13 13.68 35 14.43 310 157 4.46 / 360.43 2 2
7 8 -0.04 165 14.26 284 668 5.13 / 361.09 2 2
Average= 4.46
(KJ/cycle)

Cycle 79 GMT 26/ 1/2019 22:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 26 14.50 443 167 0.17 / 351.26 2 2
2 12 2000.32 38 11.00 3135 1310 1.48 / 352.57 2 2
3 7 1995.80 24 11.81 3222 913 2.39 / 353.49 2 2
4 13 1579.00 35 12.75 2627 1172 3.56 / 354.66 2 2
5 13 669.56 35 13.56 1321 627 4.19 / 355.29 2 2
6 8 0.00 165 14.32 286 676 4.87 / 355.96 2 2
Average= 4.45
(KJ/cycle)

Cycle 78 GMT 16/ 1/2019 22:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 26 14.51 426 161 0.16 / 346.34 2 2
2 12 2004.48 31 11.14 3116 1076 1.24 / 347.42 2 2
3 7 2001.12 24 11.99 3219 926 2.16 / 348.34 2 2
4 13 1596.60 35 12.76 2642 1180 3.34 / 349.52 2 2
5 13 840.20 35 13.44 1556 732 4.07 / 350.25 2 2
6 13 39.48 35 14.39 350 176 4.25 / 350.43 2 2
7 8 0.00 165 14.29 283 667 4.92 / 351.10 2 2
Average= 4.44
(KJ/cycle)

Cycle 77 GMT 6/ 1/2019 23: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 26 14.53 439 166 0.17 / 341.25 2 2
2 12 2006.28 31 11.17 3091 1070 1.24 / 342.32 2 2
3 7 2003.08 24 12.00 3222 928 2.16 / 343.25 2 2
4 13 1882.60 35 12.48 3067 1340 3.50 / 344.59 2 2
5 13 809.04 35 13.45 1516 714 4.22 / 345.30 2 2
6 13 86.88 35 14.30 422 211 4.43 / 345.51 2 2
7 8 0.12 165 14.31 282 666 5.09 / 346.18 2 2
Average= 4.44
(KJ/cycle)

Cycle 76 GMT 27/12/2018 23:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 26 14.54 437 165 0.17 / 336.26 2 2
2 12 2001.16 31 11.30 3089 1082 1.25 / 337.34 2 2
3 7 1997.52 24 12.03 3235 934 2.18 / 338.27 2 2
4 13 1731.48 35 12.68 2838 1260 3.44 / 339.53 2 2
5 13 818.36 35 13.47 1524 718 4.16 / 340.25 2 2
6 13 36.04 35 14.40 341 172 4.33 / 340.42 2 2
7 8 0.04 165 14.29 281 663 4.99 / 341.08 2 2
Average= 4.43
(KJ/cycle)

Cycle 75 GMT 17/12/2018 23:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 26 14.54 455 172 0.17 / 331.31 2 2
2 12 2005.72 31 11.21 3129 1087 1.26 / 332.40 2 2
3 7 2002.04 24 12.03 3235 934 2.19 / 333.33 2 2
4 13 1601.76 35 12.82 2649 1189 3.38 / 334.52 2 2
5 13 840.16 35 13.46 1553 732 4.11 / 335.26 2 2
6 13 20.48 35 14.44 317 160 4.27 / 335.42 2 2
7 8 -0.04 165 14.30 286 675 4.95 / 336.09 2 2
Average= 4.42
(KJ/cycle)

Cycle 74 GMT 8/12/2018 0:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 26 14.54 448 169 0.17 / 326.59 2 2
2 12 2000.28 31 11.34 3097 1089 1.26 / 327.67 2 2
3 7 1996.60 24 12.08 3224 935 2.19 / 328.61 2 2
4 13 1605.56 35 12.84 2651 1191 3.38 / 329.80 2 2
5 13 713.28 35 13.58 1375 654 4.04 / 330.45 2 2
6 8 0.04 165 14.32 291 688 4.73 / 331.14 2 2
Average= 4.42
(KJ/cycle)

Cycle 73 GMT 28/11/2018 0:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 26 14.56 438 166 0.17 / 321.50 2 2
2 7 2007.48 49 11.44 3212 1801 1.97 / 323.30 2 2
3 13 1881.32 37 12.51 3064 1418 3.38 / 324.72 2 2
4 13 950.36 37 13.38 1699 841 4.23 / 325.56 2 2
5 13 30.16 37 14.43 336 179 4.41 / 325.74 2 2
6 8 0.04 165 14.29 287 677 5.08 / 326.42 2 2
Average= 4.41
(KJ/cycle)

Cycle 72 GMT 18/11/2018 1: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 26 14.57 441 167 0.17 / 316.64 2 2
2 7 2001.04 49 11.53 3201 1808 1.98 / 318.45 2 2
3 13 1734.72 37 12.70 2835 1332 3.31 / 319.78 2 2
4 13 978.28 37 13.37 1754 868 4.18 / 320.65 2 2
5 8 0.20 165 14.34 290 686 4.86 / 321.33 2 2
Average= 4.40
(KJ/cycle)

Cycle 71 GMT 8/11/2018 1:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 26 14.58 459 174 0.17 / 311.86 2 2
2 7 2009.08 46 11.68 3210 1725 1.90 / 313.59 2 2
3 13 1886.76 37 12.57 3072 1429 3.33 / 315.02 2 2
4 13 848.84 37 13.48 1572 784 4.11 / 315.80 2 2
5 8 0.12 165 14.36 284 673 4.78 / 316.47 2 2
Average= 4.40
(KJ/cycle)

Cycle 70 GMT 29/10/2018 1:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 26 14.58 431 163 0.16 / 306.89 2 2
2 7 2003.64 45 11.79 3232 1715 1.88 / 308.61 2 2
3 13 1874.80 37 12.63 3029 1415 3.29 / 310.02 2 2
4 13 847.96 37 13.50 1576 787 4.08 / 310.81 2 2
5 13 23.68 37 14.45 331 177 4.26 / 310.99 2 2
6 8 0.04 165 14.30 297 701 4.96 / 311.69 2 2
Average= 4.39
(KJ/cycle)

Cycle 69 GMT 19/10/2018 2:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 26 14.58 438 166 0.17 / 301.91 2 2
2 7 2006.80 45 11.84 3228 1720 1.89 / 303.63 2 2
3 13 1884.20 37 12.63 3037 1419 3.31 / 305.05 2 2
4 13 826.40 37 13.53 1541 771 4.08 / 305.82 2 2
5 13 93.20 37 14.33 437 232 4.31 / 306.05 2 2
6 8 0.00 165 14.31 286 675 4.98 / 306.73 2 2
Average= 4.38
(KJ/cycle)

Cycle 68 GMT 9/10/2018 2:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 26 14.60 436 166 0.17 / 297.13 2 2
2 7 2003.08 45 11.93 3218 1728 1.89 / 298.86 2 2
3 13 1870.48 37 12.67 3053 1431 3.32 / 300.29 2 2
4 13 833.32 37 13.54 1548 776 4.10 / 301.07 2 2
5 8 0.16 165 14.36 287 680 4.78 / 301.75 2 2
Average= 4.37
(KJ/cycle)

Cycle 67 GMT 29/ 9/2018 2:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 26 14.58 443 168 0.17 / 292.31 2 2
2 7 2007.56 45 12.03 3230 1749 1.92 / 294.06 2 2
3 13 1881.96 37 12.70 3066 1441 3.36 / 295.50 2 2
4 13 829.28 37 13.55 1547 776 4.13 / 296.28 2 2
5 8 0.12 165 14.36 291 689 4.82 / 296.97 2 2
Average= 4.37
(KJ/cycle)

Cycle 66 GMT 19/ 9/2018 3:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 26 14.58 444 168 0.17 / 287.49 2 2
2 7 2002.20 45 12.14 3224 1761 1.93 / 289.25 2 2
3 13 1874.68 37 12.73 3050 1437 3.37 / 290.69 2 2
4 13 825.44 37 13.56 1541 773 4.14 / 291.46 2 2
5 8 0.04 165 14.33 290 686 4.83 / 292.14 2 2
Average= 4.36
(KJ/cycle)

Cycle 65 GMT 9/ 9/2018 3:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 26 14.58 447 169 0.17 / 282.65 2 2
2 7 2001.40 45 12.23 3211 1767 1.94 / 284.42 2 2
3 13 1868.00 37 12.78 3033 1434 3.37 / 285.85 2 2
4 13 825.72 37 13.57 1544 775 4.15 / 286.63 2 2
5 8 0.12 165 14.35 293 694 4.84 / 287.32 2 2
Average= 4.35
(KJ/cycle)

Cycle 64 GMT 30/ 8/2018 4:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 26 14.59 435 165 0.17 / 277.56 2 2
2 7 2003.36 46 12.30 3212 1817 1.98 / 279.38 2 2
3 13 1748.72 37 12.93 2862 1369 3.35 / 280.75 2 2
4 13 964.92 37 13.49 1735 866 4.22 / 281.62 2 2
5 13 29.12 37 14.44 336 180 4.40 / 281.80 2 2
6 8 0.04 165 14.32 289 683 5.08 / 282.48 2 2
Average= 4.35
(KJ/cycle)

Cycle 63 GMT 20/ 8/2018 4:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.52 26 14.59 445 169 0.17 / 272.73 2 2
2 7 2003.84 45 12.37 3235 1801 1.97 / 274.53 2 2
3 13 1873.68 37 12.82 3053 1448 3.42 / 275.97 2 2
4 13 790.56 37 13.62 1489 750 4.17 / 276.72 2 2
5 8 0.08 165 14.35 285 675 4.84 / 277.40 2 2
Average= 4.33
(KJ/cycle)

Cycle 62 GMT 10/ 8/2018 5:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 26 14.60 440 167 0.17 / 267.89 2 2
2 7 2001.16 45 12.46 3230 1811 1.98 / 269.70 2 2
3 13 1614.44 37 13.07 2656 1284 3.26 / 270.99 2 2
4 13 716.16 37 13.69 1381 700 3.96 / 271.69 2 2
5 13 52.60 37 14.42 371 198 4.16 / 271.88 2 2
6 8 -0.04 165 14.34 284 672 4.83 / 272.56 2 2
Average= 4.33
(KJ/cycle)

Cycle 61 GMT 31/ 7/2018 5:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 26 14.59 448 170 0.17 / 262.97 2 2
2 7 2002.96 45 12.52 3238 1824 1.99 / 264.79 2 2
3 13 1873.44 37 12.86 3063 1457 3.45 / 266.25 2 2
4 13 799.48 37 13.62 1517 764 4.22 / 267.01 2 2
5 8 0.16 165 14.35 300 710 4.93 / 267.72 2 2
Average= 4.32
(KJ/cycle)

Cycle 60 GMT 21/ 7/2018 6:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 26 14.60 463 176 0.18 / 258.05 2 2
2 7 2002.76 45 12.57 3243 1834 2.01 / 259.88 2 2
3 13 1607.32 37 13.10 2672 1295 3.31 / 261.18 2 2
4 13 719.68 37 13.69 1401 710 4.01 / 261.89 2 2
5 13 55.32 37 14.43 385 206 4.22 / 262.09 2 2
6 8 0.20 165 14.34 298 705 4.93 / 262.80 2 2
Average= 4.31
(KJ/cycle)

Cycle 59 GMT 11/ 7/2018 6:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.84 26 14.63 414 157 0.16 / 253.17 2 2
2 7 2003.32 45 12.67 3189 1818 1.98 / 254.99 2 2
3 13 1871.12 37 12.92 3002 1435 3.41 / 256.42 2 2
4 13 777.92 37 13.68 1430 724 4.13 / 257.15 2 2
5 8 0.12 165 14.35 307 727 4.86 / 257.87 2 2
Average= 4.30
(KJ/cycle)

Cycle 58 GMT 1/ 7/2018 7:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 26 14.64 393 150 0.15 / 248.40 2 2
2 7 2003.08 45 12.69 3200 1827 1.98 / 250.23 2 2
3 13 1730.32 37 13.08 2794 1352 3.33 / 251.58 2 2
4 13 674.32 37 13.76 1286 655 3.98 / 252.24 2 2
5 13 38.36 37 14.49 311 167 4.15 / 252.40 2 2
6 8 0.08 165 14.40 256 608 4.76 / 253.01 2 2
Average= 4.29
(KJ/cycle)

Cycle 57 GMT 21/ 6/2018 7:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 25 14.66 399 146 0.15 / 243.82 2 2
2 7 2003.48 46 12.74 3189 1869 2.02 / 245.69 2 2
3 13 1627.72 37 13.16 2636 1284 3.30 / 246.97 2 2
4 13 710.44 37 13.76 1325 675 3.97 / 247.65 2 2
5 8 0.24 165 14.45 254 606 4.58 / 248.25 2 2
Average= 4.28
(KJ/cycle)

Cycle 56 GMT 11/ 6/2018 8:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 25 14.65 402 147 0.15 / 239.29 2 2
2 7 2003.08 45 12.80 3190 1837 1.98 / 241.13 2 2
3 13 1612.40 37 13.17 2607 1270 3.26 / 242.40 2 2
4 13 703.36 37 13.77 1319 672 3.93 / 243.07 2 2
5 8 0.12 165 14.45 252 601 4.53 / 243.67 2 2
Average= 4.27
(KJ/cycle)

Cycle 55 GMT 1/ 6/2018 8:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 25 14.66 401 147 0.15 / 234.83 2 2
2 7 2005.60 49 12.74 3189 1991 2.14 / 236.82 2 2
3 13 1596.84 35 13.23 2576 1193 3.33 / 238.01 2 2
4 13 545.36 35 13.92 1095 533 3.86 / 238.54 2 2
5 8 0.08 165 14.46 252 601 4.47 / 239.15 2 2
Average= 4.27
(KJ/cycle)

Cycle 54 GMT 22/ 5/2018 8:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.40 25 14.67 410 150 0.15 / 230.22 2 2
2 7 2005.76 50 12.74 3201 2039 2.19 / 232.26 2 2
3 13 1586.80 35 13.25 2586 1199 3.39 / 233.46 2 2
4 13 655.40 35 13.83 1259 609 4.00 / 234.07 2 2
5 8 0.00 165 14.45 255 608 4.61 / 234.68 2 2
Average= 4.27
(KJ/cycle)

Cycle 53 GMT 12/ 5/2018 9:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 25 14.68 395 145 0.14 / 225.60 2 2
2 7 2003.72 49 12.83 3184 2002 2.15 / 227.60 2 2
3 13 1478.04 35 13.32 2413 1125 3.27 / 228.73 2 2
4 13 858.36 35 13.71 1541 739 4.01 / 229.47 2 2
5 8 0.12 165 14.46 254 606 4.62 / 230.07 2 2
Average= 4.26
(KJ/cycle)

Cycle 52 GMT 2/ 5/2018 9:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 25 14.70 400 147 0.15 / 221.10 2 2
2 7 2005.12 49 12.81 3188 2001 2.15 / 223.10 2 2
3 13 1598.56 35 13.25 2603 1207 3.36 / 224.31 2 2
4 13 560.88 35 13.93 1127 549 3.90 / 224.86 2 2
5 8 0.12 165 14.49 251 600 4.50 / 225.46 2 2
Average= 4.25
(KJ/cycle)

Cycle 51 GMT 22/ 4/2018 9: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 25 14.71 389 143 0.14 / 216.53 2 2
2 7 2003.44 49 12.82 3195 2007 2.15 / 218.54 2 2
3 13 1583.00 35 13.28 2567 1193 3.34 / 219.73 2 2
4 13 663.48 35 13.86 1271 617 3.96 / 220.35 2 2
5 8 0.12 165 14.48 254 607 4.57 / 220.95 2 2
Average= 4.25
(KJ/cycle)

Cycle 50 GMT 12/ 4/2018 9:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 25 14.71 403 148 0.15 / 211.98 2 2
2 7 2002.32 49 12.83 3183 2001 2.15 / 213.99 2 2
3 13 1589.36 33 13.30 2589 1136 3.29 / 215.12 2 2
4 13 819.24 33 13.78 1490 678 3.96 / 215.80 2 2
5 8 0.20 160 14.49 253 587 4.55 / 216.39 2 2
Average= 4.24
(KJ/cycle)

Cycle 49 GMT 2/ 4/2018 10:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 25 14.72 392 144 0.14 / 207.32 2 2
2 7 2003.24 50 12.85 3185 2046 2.19 / 209.37 2 2
3 13 1593.44 33 13.32 2586 1137 3.33 / 210.50 2 2
4 13 681.80 33 13.88 1300 595 3.92 / 211.10 2 2
5 13 42.48 33 14.58 316 152 4.07 / 211.25 2 2
6 8 -0.08 160 14.48 252 584 4.66 / 211.84 2 2
Average= 4.24
(KJ/cycle)

Cycle 48 GMT 23/ 3/2018 10:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 25 14.72 396 146 0.15 / 202.71 2 2
2 7 2000.76 49 12.85 3187 2007 2.15 / 204.72 2 2
3 13 1575.48 33 13.34 2561 1127 3.28 / 205.85 2 2
4 13 675.28 33 13.89 1281 587 3.87 / 206.44 2 2
5 13 38.92 33 14.58 314 151 4.02 / 206.59 2 2
6 8 0.08 160 14.48 255 591 4.61 / 207.18 2 2
Average= 4.23
(KJ/cycle)

Cycle 47 GMT 13/ 3/2018 11:10: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 25 14.73 407 150 0.15 / 198.22 2 2
2 7 2004.08 49 12.87 3182 2007 2.16 / 200.23 2 2
3 13 1601.44 33 13.33 2591 1140 3.30 / 201.37 2 2
4 13 704.20 33 13.88 1327 608 3.90 / 201.98 2 2
5 8 0.12 160 14.51 255 592 4.50 / 202.57 2 2
Average= 4.22
(KJ/cycle)

Cycle 46 GMT 3/ 3/2018 11:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 25 14.73 404 149 0.15 / 193.89 2 2
2 7 2001.04 49 12.85 3193 2010 2.16 / 195.90 2 2
3 13 1455.12 33 13.40 2392 1058 3.22 / 196.96 2 2
4 13 577.72 33 13.98 1151 531 3.75 / 197.49 2 2
5 8 0.20 160 14.52 251 583 4.33 / 198.07 2 2
Average= 4.21
(KJ/cycle)

Cycle 45 GMT 21/ 2/2018 11:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 25 14.75 395 146 0.15 / 189.29 2 2
2 7 2002.80 49 12.85 3179 2002 2.15 / 191.29 2 2
3 13 1594.00 33 13.34 2578 1135 3.28 / 192.42 2 2
4 13 680.68 33 13.91 1294 594 3.88 / 193.02 2 2
5 13 19.44 33 14.63 279 135 4.01 / 193.15 2 2
6 8 0.00 160 14.47 255 590 4.60 / 193.74 2 2
Average= 4.21
(KJ/cycle)

Cycle 44 GMT 11/ 2/2018 11: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 25 14.75 407 150 0.15 / 184.83 2 2
2 7 2002.12 49 12.83 3194 2008 2.16 / 186.84 2 2
3 13 1572.32 33 13.34 2560 1127 3.29 / 187.97 2 2
4 13 661.48 33 13.92 1270 583 3.87 / 188.55 2 2
5 8 0.08 160 14.52 254 590 4.46 / 189.14 2 2
Average= 4.20
(KJ/cycle)

Cycle 43 GMT 1/ 2/2018 11:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 25 14.75 406 150 0.15 / 180.29 2 2
2 7 2002.76 49 12.87 3180 2005 2.16 / 182.29 2 2
3 13 1731.92 33 13.26 2778 1216 3.37 / 183.51 2 2
4 13 682.92 33 13.91 1291 593 3.96 / 184.10 2 2
5 8 0.16 160 14.54 250 582 4.54 / 184.68 2 2
Average= 4.20
(KJ/cycle)

Cycle 42 GMT 22/ 1/2018 11: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 25 14.76 400 148 0.15 / 175.43 2 2
2 7 2006.68 49 12.83 3204 2014 2.16 / 177.45 2 2
3 13 1873.80 33 13.13 3005 1302 3.46 / 178.75 2 2
4 13 785.96 33 13.83 1442 658 4.12 / 179.41 2 2
5 13 30.04 33 14.64 295 143 4.26 / 179.55 2 2
6 8 0.08 160 14.51 252 585 4.85 / 180.14 2 2
Average= 4.19
(KJ/cycle)

Cycle 41 GMT 12/ 1/2018 11:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 25 14.75 392 145 0.14 / 170.99 2 2
2 7 2000.48 49 12.83 3185 2002 2.15 / 172.99 2 2
3 13 1575.36 33 13.34 2561 1127 3.27 / 174.12 2 2
4 13 655.56 33 13.93 1257 578 3.85 / 174.70 2 2
5 8 0.00 160 14.56 252 587 4.44 / 175.29 2 2
Average= 4.17
(KJ/cycle)

Cycle 40 GMT 2/ 1/2018 11:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.56 25 14.75 403 149 0.15 / 166.35 2 2
2 7 2002.12 50 12.82 3182 2040 2.19 / 168.39 2 2
3 13 1579.76 33 13.32 2570 1130 3.32 / 169.52 2 2
4 13 666.92 33 13.92 1277 587 3.90 / 170.10 2 2
5 13 38.80 33 14.63 313 151 4.06 / 170.25 2 2
6 8 0.04 160 14.49 256 594 4.65 / 170.85 2 2
Average= 4.17
(KJ/cycle)

Cycle 39 GMT 23/12/2017 11:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 25 14.75 398 147 0.15 / 161.80 2 2
2 7 2001.32 49 12.84 3178 1999 2.15 / 163.80 2 2
3 13 1452.72 33 13.39 2389 1056 3.20 / 164.85 2 2
4 13 702.12 33 13.90 1320 605 3.81 / 165.46 2 2
5 13 19.08 33 14.66 287 139 3.95 / 165.60 2 2
6 8 0.00 160 14.51 259 601 4.55 / 166.20 2 2
Average= 4.15
(KJ/cycle)

Cycle 38 GMT 13/12/2017 12: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 25 14.78 392 145 0.14 / 157.08 2 2
2 7 2002.36 50 12.79 3192 2041 2.19 / 159.12 2 2
3 13 1730.80 33 13.23 2773 1211 3.40 / 160.33 2 2
4 13 660.92 33 13.92 1271 584 3.98 / 160.92 2 2
5 13 15.20 33 14.67 276 134 4.11 / 161.05 2 2
6 8 0.04 160 14.49 259 600 4.71 / 161.65 2 2
Average= 4.14
(KJ/cycle)

Cycle 37 GMT 3/12/2017 12: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 25 14.76 396 146 0.15 / 152.66 2 2
2 7 2003.20 49 12.78 3184 1994 2.14 / 154.65 2 2
3 13 1472.12 33 13.36 2418 1066 3.21 / 155.72 2 2
4 13 716.72 33 13.88 1354 620 3.83 / 156.34 2 2
5 8 0.24 160 14.55 258 601 4.43 / 156.94 2 2
Average= 4.13
(KJ/cycle)

Cycle 36 GMT 23/11/2017 12: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.44 25 14.75 402 148 0.15 / 148.19 2 2
2 7 2002.08 49 12.78 3193 2000 2.15 / 150.19 2 2
3 13 1580.56 33 13.29 2569 1127 3.27 / 151.32 2 2
4 13 673.04 33 13.91 1283 589 3.86 / 151.91 2 2
5 8 0.12 160 14.52 260 604 4.47 / 152.51 2 2
Average= 4.12
(KJ/cycle)

Cycle 35 GMT 13/11/2017 12: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 25 14.75 402 148 0.15 / 143.62 2 2
2 7 2001.20 49 12.81 3191 2003 2.15 / 145.63 2 2
3 13 1596.28 33 13.28 2595 1137 3.29 / 146.76 2 2
4 13 810.48 33 13.82 1483 676 3.96 / 147.44 2 2
5 8 0.04 160 14.53 259 602 4.57 / 148.04 2 2
Average= 4.11
(KJ/cycle)

Cycle 34 GMT 3/11/2017 12:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 25 14.74 409 151 0.15 / 139.04 2 2
2 7 2002.00 49 12.82 3194 2006 2.16 / 141.05 2 2
3 13 1596.00 33 13.28 2609 1143 3.30 / 142.19 2 2
4 13 818.20 33 13.80 1500 683 3.98 / 142.88 2 2
5 8 0.16 160 14.54 257 598 4.58 / 143.48 2 2
Average= 4.10
(KJ/cycle)

Cycle 33 GMT 24/10/2017 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 25 14.74 414 153 0.15 / 134.48 2 2
2 7 2000.32 49 12.81 3200 2009 2.16 / 136.49 2 2
3 13 1579.80 33 13.30 2586 1135 3.30 / 137.62 2 2
4 13 794.88 33 13.83 1462 667 3.96 / 138.29 2 2
5 8 0.00 160 14.53 260 604 4.57 / 138.89 2 2
Average= 4.09
(KJ/cycle)

Cycle 32 GMT 14/10/2017 12:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 25 14.75 406 150 0.15 / 129.94 2 2
2 7 2001.68 50 12.84 3188 2047 2.20 / 131.99 2 2
3 13 1586.88 33 13.31 2593 1139 3.34 / 133.13 2 2
4 13 679.56 33 13.92 1294 594 3.93 / 133.72 2 2
5 8 0.08 160 14.55 260 605 4.54 / 134.33 2 2
Average= 4.07
(KJ/cycle)

Cycle 31 GMT 4/10/2017 12:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 25 14.75 403 149 0.15 / 125.44 2 2
2 7 2002.28 49 12.86 3195 2013 2.16 / 127.45 2 2
3 13 1593.92 33 13.31 2593 1139 3.30 / 128.59 2 2
4 13 682.84 33 13.93 1300 598 3.90 / 129.19 2 2
5 8 0.12 160 14.55 260 605 4.50 / 129.79 2 2
Average= 4.06
(KJ/cycle)

Cycle 30 GMT 24/ 9/2017 12:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 25 14.73 410 151 0.15 / 120.70 2 2
2 7 2010.72 45 12.95 3214 1873 2.02 / 122.57 2 2
3 13 1878.20 36 13.08 3004 1415 3.44 / 123.99 2 2
4 13 801.36 36 13.82 1470 731 4.17 / 124.72 2 2
5 8 0.00 150 14.56 261 570 4.74 / 125.29 2 2
Average= 4.04
(KJ/cycle)

Cycle 29 GMT 14/ 9/2017 12:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 25 14.78 416 154 0.15 / 116.03 2 2
2 7 2002.00 45 12.98 3199 1869 2.02 / 117.90 2 2
3 13 1735.52 36 13.22 2813 1339 3.36 / 119.24 2 2
4 13 805.40 36 13.83 1470 732 4.09 / 119.97 2 2
5 8 0.04 150 14.55 263 574 4.67 / 120.55 2 2
Average= 4.02
(KJ/cycle)

Cycle 28 GMT 4/ 9/2017 12:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 25 14.80 415 154 0.15 / 111.47 2 2
2 7 2001.44 45 13.00 3176 1858 2.01 / 113.33 2 2
3 13 1740.00 36 13.24 2806 1337 3.35 / 114.67 2 2
4 13 671.32 36 13.94 1282 643 3.99 / 115.31 2 2
5 8 0.04 150 14.56 261 570 4.56 / 115.88 2 2
Average= 4.00
(KJ/cycle)

Cycle 27 GMT 25/ 8/2017 12:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 25 14.77 421 155 0.16 / 106.95 2 2
2 7 1995.44 44 13.02 3185 1825 1.98 / 108.77 2 2
3 13 1731.96 36 13.24 2780 1325 3.31 / 110.10 2 2
4 13 666.92 36 13.95 1279 642 3.95 / 110.74 2 2
5 8 0.08 150 14.57 264 577 4.52 / 111.32 2 2
Average= 3.98
(KJ/cycle)

Cycle 26 GMT 15/ 8/2017 11:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 25 14.82 399 148 0.15 / 102.19 2 2
2 7 2002.84 44 13.06 3170 1822 1.97 / 104.02 2 2
3 13 1731.96 36 13.27 2784 1330 3.30 / 105.35 2 2
4 13 797.08 36 13.86 1459 728 4.03 / 106.07 2 2
5 13 14.92 36 14.74 282 150 4.18 / 106.22 2 2
6 8 -0.08 150 14.52 262 571 4.75 / 106.79 2 2
Average= 3.96
(KJ/cycle)

Cycle 25 GMT 5/ 8/2017 11:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 25 14.82 414 153 0.15 / 97.44 2 2
2 7 2001.20 44 13.07 3164 1820 1.97 / 99.26 2 2
3 13 1869.68 36 13.17 2987 1416 3.39 / 100.68 2 2
4 13 648.76 36 13.97 1256 632 4.02 / 101.31 2 2
5 13 29.36 36 14.70 306 162 4.18 / 101.47 2 2
6 8 0.08 150 14.54 263 574 4.76 / 102.05 2 2
Average= 3.92
(KJ/cycle)

Cycle 24 GMT 26/ 7/2017 11:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 25 14.79 415 153 0.15 / 92.78 2 2
2 7 2005.80 44 13.09 3195 1840 1.99 / 94.62 2 2
3 13 1586.04 36 13.36 2590 1246 3.24 / 95.86 2 2
4 13 681.56 36 13.96 1293 650 3.89 / 96.51 2 2
5 13 88.24 36 14.63 396 209 4.10 / 96.72 2 2
6 8 0.04 150 14.59 260 569 4.67 / 97.29 2 2
Average= 3.89
(KJ/cycle)

Cycle 23 GMT 16/ 7/2017 11:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 25 14.83 417 155 0.15 / 88.24 2 2
2 7 2001.32 44 13.11 3158 1822 1.98 / 90.06 2 2
3 13 1726.96 36 13.29 2798 1339 3.31 / 91.40 2 2
4 13 676.08 36 13.98 1274 641 3.96 / 92.04 2 2
5 8 0.04 150 14.60 265 580 4.54 / 92.62 2 2
Average= 3.86
(KJ/cycle)

Cycle 22 GMT 6/ 7/2017 11:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 25 14.83 400 148 0.15 / 83.62 2 2
2 7 2001.08 45 13.14 3178 1879 2.03 / 85.49 2 2
3 13 1736.76 36 13.29 2824 1351 3.38 / 86.85 2 2
4 13 687.56 36 13.96 1310 658 4.04 / 87.50 2 2
5 8 0.00 150 14.61 266 583 4.62 / 88.09 2 2
Average= 3.83
(KJ/cycle)

Cycle 21 GMT 26/ 6/2017 10:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 24 14.86 401 143 0.14 / 79.15 2 2
2 7 2004.32 45 13.15 3211 1900 2.04 / 81.05 2 2
3 13 1603.24 36 13.37 2618 1260 3.30 / 82.31 2 2
4 13 555.60 36 14.06 1127 570 3.87 / 82.88 2 2
5 8 0.12 150 14.60 266 583 4.46 / 83.47 2 2
Average= 3.79
(KJ/cycle)

Cycle 20 GMT 16/ 6/2017 10:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 24 14.88 404 144 0.14 / 74.37 2 2
2 7 2004.48 44 13.17 3187 1847 1.99 / 76.22 2 2
3 13 1872.16 36 13.22 2992 1424 3.42 / 77.64 2 2
4 13 646.12 36 14.00 1249 629 4.04 / 78.27 2 2
5 13 34.20 36 14.75 309 164 4.21 / 78.44 2 2
6 8 0.00 150 14.59 263 576 4.78 / 79.01 2 2
Average= 3.76
(KJ/cycle)

Cycle 19 GMT 6/ 6/2017 9:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.12 24 14.84 409 146 0.15 / 69.88 2 2
2 7 2000.28 44 13.17 3191 1849 1.99 / 71.72 2 2
3 13 1606.04 36 13.38 2620 1262 3.26 / 72.99 2 2
4 13 697.44 36 13.96 1319 663 3.92 / 73.65 2 2
5 8 0.08 150 14.63 263 577 4.50 / 74.23 2 2
Average= 3.71
(KJ/cycle)

Cycle 18 GMT 27/ 5/2017 9:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 24 14.89 402 144 0.14 / 65.38 2 2
2 7 1999.76 44 13.18 3187 1848 1.99 / 67.23 2 2
3 13 1605.20 36 13.39 2618 1262 3.25 / 68.49 2 2
4 13 675.40 36 13.97 1295 651 3.91 / 69.15 2 2
5 8 0.08 150 14.63 266 584 4.49 / 69.73 2 2
Average= 3.67
(KJ/cycle)

Cycle 17 GMT 17/ 5/2017 9: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 24 14.89 405 145 0.14 / 60.74 2 2
2 7 2001.16 45 13.20 3148 1870 2.01 / 62.61 2 2
3 13 1605.40 36 13.40 2589 1249 3.26 / 63.86 2 2
4 13 688.56 36 13.97 1306 657 3.92 / 64.51 2 2
5 13 20.04 36 14.80 289 154 4.07 / 64.67 2 2
6 8 0.00 150 14.61 262 574 4.65 / 65.24 2 2
Average= 3.62
(KJ/cycle)

Cycle 16 GMT 7/ 5/2017 9: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 24 14.87 416 148 0.15 / 56.27 2 2
2 7 1995.00 44 13.20 3164 1838 1.99 / 58.11 2 2
3 13 1596.96 36 13.39 2602 1254 3.24 / 59.36 2 2
4 13 682.76 36 13.97 1302 655 3.90 / 60.02 2 2
5 8 0.08 150 14.64 261 573 4.47 / 60.59 2 2
Average= 3.56
(KJ/cycle)

Cycle 15 GMT 27/ 4/2017 8:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 24 14.91 414 148 0.15 / 51.69 2 2
2 7 1997.24 44 13.19 3183 1847 2.00 / 53.54 2 2
3 13 1597.88 36 13.38 2609 1257 3.25 / 54.79 2 2
4 13 815.04 36 13.87 1495 746 4.00 / 55.54 2 2
5 8 0.04 150 14.65 266 585 4.58 / 56.12 2 2
Average= 3.51
(KJ/cycle)

Cycle 14 GMT 17/ 4/2017 8: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.52 24 14.93 396 142 0.14 / 46.93 2 2
2 7 1990.88 44 13.20 3162 1836 1.98 / 48.77 2 2
3 13 1734.56 34 13.35 2792 1267 3.25 / 50.03 2 2
4 13 664.16 34 14.00 1280 609 3.85 / 50.64 2 2
5 13 40.36 34 14.78 323 162 4.02 / 50.80 2 2
6 8 -0.08 190 14.56 266 736 4.75 / 51.54 2 2
Average= 3.44
(KJ/cycle)

Cycle 13 GMT 7/ 4/2017 7:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 24 14.93 398 143 0.14 / 42.27 2 2
2 7 1993.24 43 13.22 3165 1799 1.94 / 44.07 2 2
3 13 1587.88 34 13.40 2582 1176 3.12 / 45.25 2 2
4 13 694.00 34 13.97 1332 633 3.75 / 45.88 2 2
5 13 56.84 34 14.75 349 175 3.93 / 46.06 2 2
6 8 0.00 190 14.56 264 730 4.66 / 46.79 2 2
Average= 3.34
(KJ/cycle)

Cycle 12 GMT 28/ 3/2017 6:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 24 14.92 410 147 0.15 / 37.51 2 2
2 7 1991.88 43 13.20 3163 1795 1.94 / 39.31 2 2
3 13 1728.24 34 13.33 2801 1269 3.21 / 40.58 2 2
4 13 662.32 34 13.99 1280 609 3.82 / 41.19 2 2
5 13 87.00 34 14.68 404 202 4.02 / 41.39 2 2
6 8 0.04 190 14.57 268 742 4.76 / 42.13 2 2
Average= 3.24
(KJ/cycle)

Cycle 11 GMT 18/ 3/2017 6: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 24 14.93 408 146 0.15 / 33.35 2 2
2 7 1992.48 43 13.20 3172 1800 1.95 / 35.15 2 2
3 13 1466.28 31 13.47 2428 1014 2.96 / 36.16 2 2
4 13 522.96 31 14.12 1087 476 3.44 / 36.64 2 2
5 8 0.00 190 14.60 263 730 4.17 / 37.37 2 2
Average= 3.11
(KJ/cycle)

Cycle 10 GMT 8/ 3/2017 4:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 24 14.93 408 146 0.15 / 29.13 2 2
2 7 1992.20 44 13.17 3169 1836 1.98 / 30.96 2 2
3 13 1484.08 31 13.45 2443 1019 3.00 / 31.98 2 2
4 13 538.36 31 14.10 1111 486 3.49 / 32.47 2 2
5 8 0.08 190 14.60 265 735 4.22 / 33.20 2 2
Average= 3.02
(KJ/cycle)

Cycle 9 GMT 26/ 2/2017 3:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 24 14.94 397 142 0.14 / 24.92 2 2
2 7 1987.92 43 13.19 3151 1787 1.93 / 26.71 2 2
3 13 1468.24 31 13.43 2431 1012 2.94 / 27.72 2 2
4 13 624.44 31 14.02 1233 536 3.48 / 28.26 2 2
5 8 0.04 190 14.61 261 725 4.20 / 28.98 2 2
Average= 2.90
(KJ/cycle)

Cycle 8 GMT 16/ 2/2017 2:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 24 14.92 405 145 0.15 / 20.72 2 2
2 7 1980.40 46 13.12 3136 1893 2.04 / 22.61 2 2
3 13 1330.00 26 13.55 2246 791 2.83 / 23.40 2 2
4 13 676.64 26 14.01 1298 473 3.30 / 23.87 2 2
5 13 122.20 26 14.66 457 174 3.48 / 24.05 2 2
6 8 0.12 190 14.57 264 731 4.21 / 24.78 2 2
Average= 2.75
(KJ/cycle)

Cycle 7 GMT 6/ 2/2017 1:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.08 29 14.87 396 171 0.17 / 16.52 2 2
2 3 832.60 -3 15.52 0 0 0.00 / 16.52 2 2
3 3 971.28 -1 15.51 0 0 0.00 / 16.52 2 2
4 7 1984.36 46 13.09 3126 1882 2.05 / 18.40 2 2
5 13 1464.00 26 13.45 2420 846 2.90 / 19.25 2 2
6 13 652.08 26 14.00 1268 462 3.36 / 19.71 2 2
7 13 56.84 26 14.76 352 135 3.50 / 19.85 2 2
8 8 0.12 190 14.57 262 725 4.22 / 20.57 2 2
Average= 2.57
(KJ/cycle)

Cycle 6 GMT 27/ 1/2017 0:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 10 1089.28 8 14.38 1909 220 0.22 / 10.91 2 2
2 10 1151.08 6 14.27 1993 171 0.39 / 11.09 2 2
3 10 1200.28 5 14.25 2068 147 0.54 / 11.23 2 2
4 10 1239.88 4 14.24 2150 122 0.66 / 11.36 2 2
5 3 1304.92 8 14.23 2219 253 0.91 / 11.61 2 2
6 3 1099.44 3 14.47 1961 85 1.00 / 11.69 2 2
7 7 1979.28 74 12.79 3151 2982 3.98 / 14.68 2 2
8 13 790.60 25 13.87 1476 512 4.49 / 15.19 2 2
9 13 240.12 25 14.43 660 238 4.73 / 15.43 2 2
10 8 0.12 240 14.48 266 924 5.65 / 16.35 2 2
Average= 2.34
(KJ/cycle)

Cycle 5 GMT 16/ 1/2017 23:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.00 -19 15.56 0 0 0.00 / 5.18 2 2
2 3 0.00 -19 15.56 0 0 0.00 / 5.18 2 2
3 5 1467.32 12 13.46 2443 395 0.39 / 5.57 2 2
4 5 1638.76 16 13.27 2618 556 0.95 / 6.13 2 2
5 7 1975.00 74 12.61 3097 2890 3.84 / 9.02 2 2
6 13 794.04 25 13.84 1440 498 4.34 / 9.52 2 2
7 13 261.64 25 14.32 697 250 4.59 / 9.77 2 2
8 8 0.20 240 14.43 268 928 5.52 / 10.70 2 2
Average= 1.78
(KJ/cycle)

Cycle 4 GMT 6/ 1/2017 22:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.00 -19 15.56 0 0 0.00 / 4.15 2 2
2 3 -0.04 -19 15.56 0 0 0.00 / 4.15 2 2
3 7 -0.04 74 14.99 222 246 0.25 / 4.40 2 2
4 8 -0.04 240 14.80 219 778 1.02 / 5.18 2 7
Average= 1.04
(KJ/cycle)

Cycle 3 GMT 6/ 1/2017 1:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 -0.04 -19 15.55 0 0 0.00 / 3.13 2 2
2 3 -0.04 -19 15.56 0 0 0.00 / 3.13 2 2
3 7 -0.04 74 14.98 223 247 0.25 / 3.38 2 2
4 8 -0.08 240 14.79 218 774 1.02 / 4.15 2 7
Average= 1.04
(KJ/cycle)

Cycle 2 GMT 5/ 1/2017 4:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.00 -19 15.55 0 0 0.00 / 2.12 2 2
2 3 0.00 -19 15.56 0 0 0.00 / 2.12 2 2
3 7 0.00 74 14.96 222 246 0.25 / 2.37 2 2
4 8 -0.04 240 14.79 216 767 1.01 / 3.13 2 6
Average= 1.04
(KJ/cycle)

Cycle 1 GMT 4/ 1/2017 6:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 3 0.00 -19 15.55 0 0 0.00 / 1.08 2 2
2 3 0.00 -19 15.56 0 0 0.00 / 1.08 2 2
3 7 0.00 75 14.95 227 255 0.25 / 1.34 2 2
4 8 0.00 240 14.76 221 783 1.04 / 2.12 2 2
Average= 1.06
(KJ/cycle)

Cycle 0 GMT 3/ 1/2017 20:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 0.04 24 14.60 224 78 0.08 / 0.08 2 2
2 7 0.08 74 14.60 222 240 0.32 / 0.32 2 2
3 8 0.04 240 14.70 217 766 1.08 / 1.08 2 2
Average= 1.08