SIO Argo Site:
Pump Diagnostics Page   



Serial= 7027 Iridium= 46549 WMO= 3900838     Return  


Cycle 4

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 100.16 30 14.55 461 201 0.20 / 16.76 6 6
2 880.52 -2 14.55 461 13 0.21 / 16.78 6 6
3 1428.84 70 12.90 2243 2025 2.24 / 18.80 6 35
4 989.20 25 13.34 1757 586 2.83 / 19.39 6 55
5 308.04 24 14.06 859 290 3.12 / 19.68 6 68
6 0.12 25 14.63 403 147 3.26 / 19.83 6 69
7 0.00 297 14.02 366 1524 4.79 / 21.35 6 211
Average= 4.27 (KJ/cycle)

Cycle 3

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 110.92 36 14.42 480 249 0.25 / 12.12 6 6
2 678.68 -5 14.42 480 35 0.28 / 12.16 6 6
3 1327.44 70 12.95 2128 1929 2.21 / 14.09 6 34
4 888.04 25 13.40 1628 545 2.76 / 14.63 6 52
5 215.56 25 14.17 722 256 3.01 / 14.89 6 64
6 16.96 25 14.51 430 156 3.17 / 15.05 6 65
7 0.16 297 13.99 365 1517 4.69 / 16.56 6 249
Average= 4.14 (KJ/cycle)

Cycle 2

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 104.32 30 14.42 480 208 0.21 / 6.80 6 6
2 1545.36 13 13.14 2384 407 0.61 / 7.21 6 16
3 1617.76 70 12.59 2478 2184 2.80 / 9.39 16 39
4 898.48 25 13.27 1688 560 3.36 / 9.95 6 61
5 180.28 25 14.15 691 244 3.60 / 10.20 6 70
6 29.20 25 14.40 455 164 3.77 / 10.36 6 68
7 0.04 25 14.41 405 146 3.91 / 10.51 6 67
8 0.08 266 13.94 369 1368 5.28 / 11.88 6 155
Average= 3.96 (KJ/cycle)

Cycle 1

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 108.96 25 14.55 500 182 0.18 / 2.55 6 6
2 1209.84 70 12.72 2072 1845 2.03 / 4.39 14 45
3 464.72 25 13.67 1120 383 2.41 / 4.77 6 62
4 40.04 24 14.33 493 170 2.58 / 4.94 6 65
5 0.08 305 13.92 389 1652 4.23 / 6.59 6 144
Average= 3.30 (KJ/cycle)

Cycle 0

Number Pressure (db) Time (s) Voltage (V) Current (ma) Energy (J) Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 113.48 70 14.19 519 516 0.52 / 0.52 251 9
2 96.84 25 14.45 530 191 0.71 / 0.71 6 12
3 0.12 323 14.25 360 1657 2.36 / 2.36 6 184
Average= 2.36 (KJ/cycle)