SIO Argo Site:
Pump Diagnostics Page   



Serial= 7715 WMO= 2903137

Return

←PreviousNext→

Cycle 53 GMT 26/ 4/2024 17:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 56 15.05 451 380 0.38 / 265.46 5 7
2 3 663.64 -5 15.46 0 0 0.00 / 265.46 5 7
3 7 2010.92 40 14.72 3197 1882 2.26 / 267.34 7 18
4 13 1303.48 20 14.80 2259 669 2.93 / 268.01 5 28
5 13 852.92 20 14.87 1630 485 3.42 / 268.50 5 30
6 13 173.72 20 15.06 624 188 3.60 / 268.68 5 27
7 13 46.52 20 15.09 421 127 3.73 / 268.81 5 25
8 8 0.04 276 15.05 328 1362 5.09 / 270.17 5 134
Average= 5.00
(KJ/cycle)

Cycle 52 GMT 16/ 4/2024 10:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.12 50 15.06 468 352 0.35 / 259.90 5 7
2 5 1306.28 8 15.03 2258 272 0.62 / 260.17 5 20
3 7 2010.36 41 14.73 3187 1925 2.55 / 262.10 20 21
4 13 1439.04 20 14.77 2431 718 3.27 / 262.81 5 28
5 13 963.04 20 14.85 1788 531 3.80 / 263.35 5 32
6 13 227.28 20 15.06 711 214 4.01 / 263.56 5 29
7 13 59.16 20 15.11 442 134 4.15 / 263.69 5 27
8 8 0.04 278 15.06 331 1386 5.53 / 265.08 5 153
Average= 5.00
(KJ/cycle)

Cycle 51 GMT 6/ 4/2024 4:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.48 50 15.05 477 359 0.36 / 254.77 5 7
2 7 2006.32 40 14.74 3177 1873 2.23 / 256.65 7 19
3 13 1449.72 20 14.78 2434 719 2.95 / 257.37 5 28
4 13 873.24 20 14.89 1648 491 3.44 / 257.86 5 32
5 13 201.36 20 15.07 672 203 3.64 / 258.06 5 28
6 13 59.16 20 15.12 431 130 3.78 / 258.19 5 24
7 8 0.04 278 15.07 324 1357 5.13 / 259.55 5 140
Average= 4.99
(KJ/cycle)

Cycle 50 GMT 26/ 3/2024 21:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 45 15.06 455 308 0.31 / 249.39 5 7
2 10 1052.32 4 15.12 1889 114 0.42 / 249.51 5 15
3 3 1084.92 2 15.14 1929 58 0.48 / 249.56 5 16
4 7 2002.12 40 14.73 3190 1880 2.36 / 251.44 16 19
5 13 1449.32 20 14.77 2458 726 3.09 / 252.17 5 28
6 13 959.72 20 14.86 1785 531 3.62 / 252.70 5 30
7 13 230.92 20 15.07 714 215 3.83 / 252.92 5 29
8 13 61.36 20 15.11 448 135 3.97 / 253.05 5 27
9 8 0.08 276 15.07 328 1364 5.33 / 254.42 5 132
Average= 4.99
(KJ/cycle)

Cycle 49 GMT 16/ 3/2024 15: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 122.44 42 15.06 473 299 0.30 / 244.08 5 6
2 10 1005.88 4 15.11 1815 110 0.41 / 244.19 5 13
3 7 2007.80 40 14.73 3202 1887 2.30 / 246.08 13 19
4 13 1557.80 20 14.76 2604 769 3.06 / 246.84 5 26
5 13 890.68 20 14.88 1685 501 3.57 / 247.35 5 31
6 13 187.72 20 15.08 651 196 3.76 / 247.54 5 28
7 13 66.08 20 15.12 450 136 3.90 / 247.68 5 25
8 13 19.20 20 15.13 372 113 4.01 / 247.79 5 24
9 8 0.04 259 15.07 331 1292 5.30 / 249.08 5 144
Average= 4.98
(KJ/cycle)

Cycle 48 GMT 6/ 3/2024 8:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.44 50 15.08 470 354 0.35 / 239.01 5 7
2 3 752.60 -4 15.46 0 0 0.00 / 239.01 5 7
3 7 2010.08 40 14.74 3208 1891 2.25 / 240.90 7 19
4 13 1345.20 20 14.81 2287 677 2.92 / 241.57 5 27
5 13 800.96 20 14.90 1556 464 3.39 / 242.04 5 29
6 13 229.20 20 15.06 717 216 3.60 / 242.25 5 28
7 13 82.28 20 15.10 479 145 3.75 / 242.40 5 26
8 13 20.48 20 15.11 374 113 3.86 / 242.51 5 25
9 8 0.00 257 15.06 328 1269 5.13 / 243.78 5 134
Average= 4.98
(KJ/cycle)

Cycle 47 GMT 25/ 2/2024 1:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.04 41 15.07 476 294 0.29 / 233.56 5 6
2 10 1008.20 4 15.15 1766 107 0.40 / 233.67 5 13
3 10 1118.16 3 15.12 1982 90 0.49 / 233.76 5 15
4 3 1128.64 3 15.12 2012 91 0.58 / 233.85 5 15
5 7 2007.20 40 14.75 3176 1874 2.46 / 235.72 15 20
6 13 1432.28 20 14.79 2427 718 3.17 / 236.44 5 28
7 13 849.00 20 14.90 1619 482 3.66 / 236.92 5 30
8 13 227.88 20 15.08 712 215 3.87 / 237.14 5 29
9 13 70.68 20 15.12 458 138 4.01 / 237.28 5 26
10 8 0.16 276 15.09 330 1374 5.38 / 238.65 5 135
Average= 4.97
(KJ/cycle)

Cycle 46 GMT 14/ 2/2024 19:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 40 15.06 471 284 0.28 / 228.43 5 7
2 3 1019.48 1 15.18 1840 28 0.31 / 228.46 5 15
3 7 2008.08 40 14.75 3208 1893 2.20 / 230.35 15 19
4 13 1370.96 20 14.80 2347 695 2.90 / 231.05 5 27
5 13 803.12 20 14.92 1565 467 3.37 / 231.52 5 30
6 13 218.68 20 15.08 707 213 3.58 / 231.73 5 29
7 13 68.28 20 15.13 459 139 3.72 / 231.87 5 26
8 13 19.16 20 15.13 372 113 3.83 / 231.98 5 24
9 8 0.08 257 15.08 332 1287 5.12 / 233.27 5 148
Average= 4.96
(KJ/cycle)

Cycle 45 GMT 4/ 2/2024 12:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 52 15.07 482 378 0.38 / 223.32 5 7
2 3 616.00 -6 15.47 0 0 0.00 / 223.32 5 7
3 7 2013.04 41 14.75 3184 1926 2.30 / 225.25 7 20
4 13 1537.84 20 14.78 2558 756 3.06 / 226.00 5 26
5 13 810.04 20 14.92 1557 465 3.52 / 226.47 5 29
6 13 138.52 20 15.10 581 175 3.70 / 226.64 5 27
7 13 54.16 20 15.12 434 131 3.83 / 226.78 5 26
8 8 0.12 276 15.08 330 1373 5.20 / 228.15 5 140
Average= 4.96
(KJ/cycle)

Cycle 44 GMT 25/ 1/2024 5:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.32 55 15.09 465 386 0.39 / 218.17 5 7
2 3 888.92 -2 15.48 0 0 0.00 / 218.17 5 7
3 7 2010.96 40 14.76 3173 1873 2.26 / 220.04 7 19
4 13 1448.92 20 14.79 2471 731 2.99 / 220.77 5 26
5 13 685.76 20 14.97 1390 416 3.41 / 221.19 5 29
6 13 235.96 20 15.09 726 219 3.63 / 221.41 5 29
7 13 55.36 20 15.13 446 135 3.76 / 221.54 5 28
8 8 0.12 276 15.09 337 1404 5.16 / 222.94 5 146
Average= 4.95
(KJ/cycle)

Cycle 43 GMT 14/ 1/2024 23: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 51 15.09 463 356 0.36 / 212.87 5 7
2 3 907.52 -1 15.48 0 0 0.00 / 212.87 5 7
3 7 2011.88 40 14.74 3224 1901 2.26 / 214.77 7 20
4 13 1458.48 20 14.79 2482 734 2.99 / 215.51 5 29
5 13 851.76 20 14.92 1645 491 3.48 / 216.00 5 31
6 13 234.96 20 15.11 731 221 3.70 / 216.22 5 29
7 13 59.36 20 15.15 453 137 3.84 / 216.36 5 27
8 13 15.84 20 15.16 375 114 3.95 / 216.47 5 27
9 8 0.00 257 15.10 338 1312 5.27 / 217.78 5 147
Average= 4.95
(KJ/cycle)

Cycle 42 GMT 4/ 1/2024 17:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 54 15.09 480 391 0.39 / 207.74 5 7
2 3 796.00 -3 15.48 0 0 0.00 / 207.74 5 7
3 7 2007.08 40 14.75 3191 1883 2.27 / 209.62 7 20
4 13 1446.40 20 14.79 2470 731 3.00 / 210.35 5 28
5 13 759.04 20 14.95 1500 448 3.45 / 210.80 5 31
6 13 189.84 20 15.12 662 200 3.65 / 211.00 5 29
7 13 48.52 20 15.15 433 131 3.78 / 211.13 5 26
8 8 0.04 274 15.11 334 1383 5.17 / 212.52 5 131
Average= 4.94
(KJ/cycle)

Cycle 41 GMT 25/12/2023 10:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.24 50 15.10 483 365 0.36 / 202.30 5 7
2 3 947.44 -1 15.49 0 0 0.00 / 202.30 5 7
3 5 1301.24 7 15.08 2277 240 0.61 / 202.54 5 22
4 7 2005.96 41 14.74 3179 1921 2.53 / 204.46 22 21
5 13 1435.60 20 14.79 2440 722 3.25 / 205.19 5 30
6 13 747.00 20 14.96 1482 443 3.69 / 205.63 5 32
7 13 175.88 20 15.13 632 191 3.88 / 205.82 5 28
8 13 52.68 20 15.16 436 132 4.01 / 205.95 5 26
9 8 -0.04 274 15.11 337 1395 5.41 / 207.35 5 129
Average= 4.94
(KJ/cycle)

Cycle 40 GMT 15/12/2023 4:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 46 15.11 460 320 0.32 / 197.03 5 7
2 10 1012.24 4 15.18 1799 109 0.43 / 197.14 5 13
3 3 1018.92 1 15.21 1816 28 0.46 / 197.16 5 13
4 7 2002.84 41 14.74 3194 1930 2.39 / 199.09 13 22
5 13 1429.12 20 14.81 2420 717 3.10 / 199.81 5 30
6 13 719.40 20 14.97 1446 433 3.54 / 200.24 5 32
7 13 147.88 20 15.13 593 179 3.72 / 200.42 5 28
8 13 43.44 20 15.16 420 127 3.84 / 200.55 5 26
9 8 -0.04 274 15.11 335 1387 5.23 / 201.94 5 147
Average= 4.93
(KJ/cycle)

Cycle 39 GMT 4/12/2023 21:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 44 15.11 476 316 0.32 / 191.88 5 7
2 10 1024.00 3 15.19 1859 85 0.40 / 191.96 5 15
3 7 2012.68 40 14.75 3202 1889 2.29 / 193.85 15 22
4 13 1421.04 20 14.81 2421 717 3.01 / 194.57 5 29
5 13 716.64 20 14.97 1444 432 3.44 / 195.00 5 31
6 13 160.92 20 15.14 618 187 3.63 / 195.19 5 28
7 13 41.60 20 15.17 424 129 3.76 / 195.32 5 26
8 8 0.04 272 15.11 338 1389 5.14 / 196.71 5 134
Average= 4.92
(KJ/cycle)

Cycle 38 GMT 24/11/2023 15:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.28 38 15.11 493 283 0.28 / 186.55 5 7
2 10 1006.92 5 15.17 1762 134 0.42 / 186.68 5 13
3 10 1046.64 3 15.14 1901 86 0.50 / 186.77 5 16
4 7 2011.96 41 14.76 3206 1940 2.44 / 188.71 16 20
5 13 1428.36 20 14.81 2437 722 3.17 / 189.43 5 30
6 13 727.84 20 14.98 1460 437 3.60 / 189.87 5 31
7 13 172.00 20 15.14 629 190 3.79 / 190.06 5 27
8 13 46.72 20 15.17 428 130 3.92 / 190.19 5 24
9 8 0.08 274 15.13 331 1372 5.29 / 191.56 5 136
Average= 4.91
(KJ/cycle)

Cycle 37 GMT 14/11/2023 8:47: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 39 15.11 469 276 0.28 / 181.41 5 7
2 7 2005.56 40 14.74 3214 1895 2.17 / 183.31 7 22
3 13 1431.92 20 14.82 2421 718 2.89 / 184.02 5 30
4 13 738.92 20 14.98 1464 439 3.33 / 184.46 5 33
5 13 249.72 20 15.11 750 227 3.55 / 184.69 5 30
6 13 71.84 20 15.16 476 144 3.70 / 184.83 5 28
7 13 17.68 20 15.17 384 117 3.82 / 184.95 5 26
8 8 0.00 255 15.12 342 1319 5.13 / 186.27 5 130
Average= 4.90
(KJ/cycle)

Cycle 36 GMT 4/11/2023 2: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 42 15.12 472 300 0.30 / 176.24 5 6
2 3 838.36 -3 15.49 0 0 0.00 / 176.24 5 6
3 7 2006.68 40 14.76 3211 1896 2.20 / 178.13 6 21
4 13 1521.12 20 14.80 2546 754 2.95 / 178.88 5 28
5 13 841.16 20 14.94 1623 485 3.43 / 179.37 5 33
6 13 172.08 20 15.14 641 194 3.63 / 179.56 5 28
7 13 92.32 20 15.16 512 155 3.78 / 179.72 5 28
8 8 -0.04 276 15.13 339 1416 5.20 / 181.13 5 148
Average= 4.90
(KJ/cycle)

Cycle 35 GMT 24/10/2023 19:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 40 15.15 464 281 0.28 / 170.97 5 6
2 10 1033.12 3 15.16 1865 85 0.37 / 171.05 5 12
3 7 2004.52 40 14.77 3198 1889 2.26 / 172.94 12 20
4 13 1549.12 20 14.81 2570 761 3.02 / 173.71 5 26
5 13 801.88 20 14.97 1559 467 3.48 / 174.17 5 31
6 13 218.40 20 15.13 707 214 3.70 / 174.39 5 28
7 13 77.32 20 15.17 475 144 3.84 / 174.53 5 25
8 8 0.08 278 15.13 334 1405 5.25 / 175.94 5 152
Average= 4.89
(KJ/cycle)

Cycle 34 GMT 14/10/2023 13: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 37 15.14 482 270 0.27 / 165.81 5 6
2 10 1045.92 4 15.14 1878 114 0.38 / 165.92 5 13
3 7 2007.88 40 14.78 3187 1884 2.27 / 167.81 13 20
4 13 1445.76 20 14.84 2437 723 2.99 / 168.53 5 29
5 13 743.60 20 15.00 1488 446 3.44 / 168.98 5 30
6 13 204.12 20 15.15 668 202 3.64 / 169.18 5 26
7 13 125.60 20 15.17 538 163 3.80 / 169.34 5 24
8 8 0.16 276 15.15 322 1346 5.15 / 170.69 5 132
Average= 4.88
(KJ/cycle)

Cycle 33 GMT 4/10/2023 6:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 33 15.14 466 233 0.23 / 160.65 5 6
2 10 1091.32 4 15.14 1957 119 0.35 / 160.77 5 15
3 7 2013.16 40 14.76 3213 1897 2.25 / 162.67 15 20
4 13 1359.08 20 14.86 2325 691 2.94 / 163.36 5 29
5 13 690.76 20 15.01 1401 421 3.36 / 163.78 5 31
6 13 210.32 20 15.15 689 209 3.57 / 163.99 5 28
7 13 114.92 20 15.17 535 162 3.73 / 164.15 5 27
8 8 0.12 274 15.14 335 1390 5.12 / 165.54 5 132
Average= 4.87
(KJ/cycle)

Cycle 32 GMT 23/ 9/2023 23:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.92 35 15.14 481 255 0.25 / 155.73 5 7
2 3 909.56 -1 15.51 0 0 0.00 / 155.73 5 7
3 7 2003.12 40 14.77 3167 1871 2.13 / 157.60 7 21
4 13 1325.72 20 14.87 2274 676 2.80 / 158.28 5 29
5 13 689.64 20 15.02 1401 421 3.22 / 158.70 5 31
6 13 221.56 20 15.15 704 213 3.44 / 158.91 5 28
7 13 64.92 20 15.19 449 136 3.57 / 159.05 5 24
8 8 0.04 276 15.15 327 1367 4.94 / 160.42 5 137
Average= 4.86
(KJ/cycle)

Cycle 31 GMT 13/ 9/2023 16:54: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 121.28 39 15.16 472 279 0.28 / 150.62 5 6
2 3 825.08 -3 15.51 0 0 0.00 / 150.62 5 6
3 7 2006.04 40 14.78 3207 1896 2.18 / 152.52 6 20
4 13 1446.12 20 14.83 2461 730 2.90 / 153.25 5 29
5 13 852.32 20 14.96 1636 489 3.39 / 153.74 5 33
6 13 230.04 20 15.15 720 218 3.61 / 153.96 5 29
7 13 80.56 20 15.19 474 144 3.76 / 154.10 5 25
8 8 0.12 276 15.16 329 1377 5.13 / 155.48 5 129
Average= 4.86
(KJ/cycle)

Cycle 30 GMT 3/ 9/2023 10:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 39 15.16 450 266 0.27 / 145.51 5 6
2 7 2005.88 40 14.79 3174 1878 2.14 / 147.39 12 20
3 13 1656.68 20 14.81 2713 804 2.95 / 148.19 5 26
4 13 706.56 20 15.02 1424 428 3.38 / 148.62 5 30
5 13 237.68 20 15.16 722 219 3.59 / 148.84 5 27
6 13 81.56 20 15.20 471 143 3.74 / 148.98 5 22
7 8 0.04 278 15.16 323 1361 5.10 / 150.35 5 151
Average= 4.85
(KJ/cycle)

Cycle 29 GMT 24/ 8/2023 4:11: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.80 34 15.16 483 249 0.25 / 140.20 5 6
2 10 1012.40 4 15.19 1765 107 0.36 / 140.31 5 12
3 3 1065.24 2 15.22 1872 57 0.41 / 140.37 5 17
4 7 2004.28 40 14.79 3194 1890 2.30 / 142.26 17 20
5 13 1525.88 20 14.83 2561 760 3.06 / 143.02 5 27
6 13 803.00 20 15.00 1553 466 3.53 / 143.48 5 31
7 13 233.40 20 15.16 721 219 3.75 / 143.70 5 27
8 13 137.80 20 15.18 568 172 3.92 / 143.87 5 26
9 8 0.16 278 15.17 326 1375 5.29 / 145.25 5 142
Average= 4.84
(KJ/cycle)

Cycle 28 GMT 13/ 8/2023 21:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.36 36 15.16 485 265 0.26 / 135.22 5 7
2 3 917.12 -1 15.52 0 0 0.00 / 135.22 5 7
3 7 2009.64 40 14.79 3205 1896 2.16 / 137.11 7 20
4 13 1313.32 20 14.89 2274 677 2.84 / 137.79 5 29
5 13 737.64 20 15.02 1459 438 3.28 / 138.23 5 31
6 13 193.04 20 15.18 664 202 3.48 / 138.43 5 26
7 13 103.44 20 15.20 506 154 3.63 / 138.58 5 24
8 8 0.04 276 15.17 327 1369 5.00 / 139.95 5 146
Average= 4.83
(KJ/cycle)

Cycle 27 GMT 3/ 8/2023 14:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.20 37 15.17 467 262 0.26 / 130.15 5 6
2 3 959.76 -1 15.52 0 0 0.00 / 130.15 5 6
3 7 2004.28 40 14.80 3193 1890 2.15 / 132.04 6 21
4 13 1425.16 20 14.87 2422 720 2.87 / 132.76 5 28
5 13 723.12 20 15.04 1444 434 3.31 / 133.20 5 30
6 13 250.08 20 15.16 755 229 3.54 / 133.43 5 28
7 13 77.20 20 15.21 473 144 3.68 / 133.57 5 25
8 8 0.32 276 15.17 330 1382 5.06 / 134.95 5 133
Average= 4.82
(KJ/cycle)

Cycle 26 GMT 24/ 7/2023 8:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.44 40 15.17 484 294 0.29 / 125.04 5 6
2 3 849.44 -2 15.52 0 0 0.00 / 125.04 5 6
3 7 2009.44 41 14.80 3199 1941 2.23 / 126.98 6 20
4 13 1418.12 20 14.88 2413 718 2.95 / 127.69 5 29
5 13 725.68 20 15.04 1445 435 3.39 / 128.13 5 30
6 13 251.28 20 15.16 747 226 3.61 / 128.36 5 29
7 13 80.60 20 15.21 474 144 3.76 / 128.50 5 24
8 8 0.12 276 15.17 332 1390 5.15 / 129.89 5 144
Average= 4.81
(KJ/cycle)

Cycle 25 GMT 14/ 7/2023 2: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 35 15.19 450 239 0.24 / 119.82 5 6
2 10 1034.88 4 15.20 1805 110 0.35 / 119.93 5 12
3 3 1042.20 1 15.22 1897 29 0.38 / 119.96 5 19
4 7 2011.72 40 14.80 3208 1899 2.28 / 121.86 19 19
5 13 1326.64 20 14.90 2295 684 2.96 / 122.54 5 29
6 13 750.28 20 15.03 1494 449 3.41 / 122.99 5 30
7 13 181.76 20 15.19 649 197 3.61 / 123.19 5 28
8 13 93.76 20 15.21 510 155 3.76 / 123.34 5 26
9 8 0.00 274 15.18 337 1402 5.16 / 124.74 5 131
Average= 4.80
(KJ/cycle)

Cycle 24 GMT 3/ 7/2023 19:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 35 15.18 473 251 0.25 / 114.71 5 6
2 7 2010.56 41 14.81 3212 1950 2.20 / 116.66 8 20
3 13 1436.92 20 14.88 2420 720 2.92 / 117.38 5 29
4 13 729.36 20 15.05 1457 439 3.36 / 117.82 5 31
5 13 166.72 20 15.20 627 191 3.55 / 118.01 5 27
6 13 86.60 20 15.22 498 152 3.70 / 118.16 5 25
7 8 0.08 274 15.18 340 1414 5.12 / 119.58 5 131
Average= 4.78
(KJ/cycle)

Cycle 23 GMT 23/ 6/2023 12:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.04 34 15.19 485 250 0.25 / 109.55 5 6
2 3 1036.20 1 15.23 1867 28 0.28 / 109.58 5 14
3 7 2004.88 40 14.83 3200 1898 2.18 / 111.48 14 19
4 13 1449.00 20 14.88 2471 735 2.91 / 112.21 5 27
5 13 753.00 20 15.05 1496 450 3.36 / 112.66 5 30
6 13 289.32 20 15.17 805 244 3.61 / 112.91 5 29
7 13 51.72 20 15.23 439 134 3.74 / 113.04 5 25
8 8 0.12 276 15.18 339 1420 5.16 / 114.46 5 141
Average= 4.77
(KJ/cycle)

Cycle 22 GMT 13/ 6/2023 6:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.56 33 15.19 475 238 0.24 / 104.51 5 6
2 3 1032.04 1 15.26 1848 28 0.27 / 104.54 5 15
3 7 2003.08 40 14.82 3186 1889 2.15 / 106.43 15 21
4 13 1425.24 20 14.90 2400 715 2.87 / 107.15 5 27
5 13 721.36 20 15.06 1446 436 3.31 / 107.58 5 30
6 13 149.52 20 15.22 595 181 3.49 / 107.76 5 27
7 13 47.88 20 15.24 427 130 3.62 / 107.89 5 24
8 8 0.00 274 15.19 338 1407 5.02 / 109.30 5 131
Average= 4.75
(KJ/cycle)

Cycle 21 GMT 2/ 6/2023 23:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.84 34 15.19 483 249 0.25 / 99.37 5 6
2 3 954.72 -1 15.54 0 0 0.00 / 99.37 5 6
3 7 2005.60 40 14.83 3183 1888 2.14 / 101.26 6 19
4 13 1430.44 20 14.91 2408 718 2.86 / 101.98 5 28
5 13 843.16 20 15.03 1622 488 3.34 / 102.47 5 30
6 13 235.32 20 15.19 734 223 3.57 / 102.69 5 29
7 13 58.88 20 15.23 456 139 3.71 / 102.83 5 26
8 13 14.16 20 15.24 379 116 3.82 / 102.95 5 26
9 8 0.00 257 15.19 341 1331 5.15 / 104.28 5 146
Average= 4.74
(KJ/cycle)

Cycle 20 GMT 23/ 5/2023 17:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.52 33 15.20 481 241 0.24 / 94.23 5 6
2 10 1012.32 3 15.19 1834 84 0.32 / 94.31 5 12
3 3 958.48 -1 15.54 0 0 0.08 / 94.31 5 12
4 7 2005.32 40 14.83 3188 1891 2.22 / 96.20 12 18
5 13 1421.20 20 14.91 2401 716 2.93 / 96.92 5 27
6 13 741.04 20 15.07 1478 445 3.38 / 97.36 5 31
7 13 168.88 20 15.21 644 196 3.57 / 97.56 5 28
8 13 46.84 20 15.24 441 134 3.71 / 97.69 5 25
9 8 0.12 276 15.20 341 1431 5.14 / 99.12 5 144
Average= 4.72
(KJ/cycle)

Cycle 19 GMT 13/ 5/2023 11: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.40 33 15.19 489 245 0.25 / 89.15 5 6
2 3 955.12 -1 15.54 0 0 0.00 / 89.15 5 6
3 7 2004.76 40 14.83 3207 1902 2.15 / 91.05 6 20
4 13 1347.72 20 14.92 2341 699 2.85 / 91.75 5 29
5 13 770.36 20 15.06 1509 455 3.30 / 92.20 5 30
6 13 188.28 20 15.21 670 204 3.50 / 92.41 5 28
7 13 44.20 20 15.25 437 133 3.64 / 92.54 5 26
8 8 0.04 276 15.20 345 1447 5.09 / 93.99 5 146
Average= 4.70
(KJ/cycle)

Cycle 18 GMT 3/ 5/2023 4:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.36 33 15.20 481 241 0.24 / 84.02 5 6
2 7 2006.92 40 14.83 3237 1920 2.16 / 85.94 6 18
3 13 1332.32 20 14.94 2295 686 2.85 / 86.63 5 28
4 13 865.48 20 15.03 1664 500 3.35 / 87.13 5 31
5 13 158.92 20 15.23 620 189 3.54 / 87.31 5 27
6 13 38.12 20 15.25 424 129 3.67 / 87.44 5 25
7 8 0.16 274 15.20 350 1458 5.12 / 88.90 5 135
Average= 4.68
(KJ/cycle)

Cycle 17 GMT 22/ 4/2023 22: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 32 15.21 480 234 0.23 / 78.90 5 6
2 3 1039.16 1 15.26 1888 29 0.26 / 78.93 5 17
3 7 2009.72 40 14.84 3214 1908 2.17 / 80.84 17 19
4 13 1341.12 20 14.94 2316 692 2.86 / 81.53 5 26
5 13 766.88 20 15.07 1522 459 3.32 / 81.99 5 29
6 13 172.68 20 15.22 642 195 3.52 / 82.19 5 28
7 13 42.04 20 15.25 438 134 3.65 / 82.32 5 26
8 8 0.04 274 15.21 350 1459 5.11 / 83.78 5 138
Average= 4.65
(KJ/cycle)

Cycle 16 GMT 12/ 4/2023 15:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 33 15.21 485 243 0.24 / 73.86 5 6
2 3 942.92 -1 15.55 0 0 0.00 / 73.86 5 6
3 7 2006.00 40 14.85 3182 1890 2.13 / 75.75 6 19
4 13 1426.68 20 14.92 2431 725 2.86 / 76.48 5 26
5 13 736.60 20 15.08 1471 444 3.30 / 76.92 5 29
6 13 160.44 20 15.24 615 187 3.49 / 77.11 5 28
7 13 43.36 20 15.26 424 129 3.62 / 77.24 5 26
8 8 -0.04 274 15.21 344 1434 5.05 / 78.67 5 141
Average= 4.63
(KJ/cycle)

Cycle 15 GMT 2/ 4/2023 9: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 31 15.21 489 231 0.23 / 68.71 5 6
2 10 1030.80 3 15.21 1845 84 0.31 / 68.80 5 14
3 7 2010.88 40 14.85 3204 1903 2.22 / 70.70 14 18
4 13 1346.80 20 14.95 2311 691 2.91 / 71.39 5 27
5 13 782.68 20 15.07 1543 465 3.37 / 71.86 5 30
6 13 185.92 20 15.23 659 201 3.57 / 72.06 5 28
7 13 24.52 20 15.27 397 121 3.70 / 72.18 5 25
8 8 0.08 274 15.22 345 1439 5.13 / 73.62 5 138
Average= 4.60
(KJ/cycle)

Cycle 14 GMT 23/ 3/2023 2:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 31 15.21 490 231 0.23 / 63.54 5 6
2 7 2014.36 40 14.84 3217 1910 2.14 / 65.45 6 20
3 13 1546.88 20 14.91 2566 765 2.91 / 66.22 5 28
4 13 814.48 20 15.07 1577 475 3.38 / 66.69 5 31
5 13 215.16 20 15.22 714 217 3.60 / 66.91 5 29
6 13 24.64 20 15.28 397 121 3.72 / 67.03 5 26
7 8 0.04 274 15.22 348 1451 5.17 / 68.48 5 140
Average= 4.57
(KJ/cycle)

Cycle 13 GMT 12/ 3/2023 20: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 31 15.22 488 230 0.23 / 58.56 5 7
2 7 2008.36 40 14.86 3182 1891 2.12 / 60.45 7 20
3 13 1326.32 20 14.96 2296 687 2.81 / 61.14 5 28
4 13 739.12 20 15.09 1467 443 3.25 / 61.58 5 31
5 13 139.76 20 15.25 591 180 3.43 / 61.76 5 28
6 13 15.52 20 15.28 378 116 3.55 / 61.87 5 26
7 8 -0.08 272 15.22 347 1437 4.98 / 63.31 5 131
Average= 4.52
(KJ/cycle)

Cycle 12 GMT 2/ 3/2023 13:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 31 15.22 486 229 0.23 / 53.49 5 7
2 7 2004.80 40 14.86 3183 1892 2.12 / 55.39 7 19
3 13 1535.60 20 14.92 2552 762 2.88 / 56.15 5 27
4 13 706.32 20 15.11 1420 429 3.31 / 56.58 5 31
5 13 142.08 20 15.26 596 182 3.49 / 56.76 5 27
6 8 0.12 295 15.24 349 1569 5.06 / 58.33 5 149
Average= 4.49
(KJ/cycle)

Cycle 11 GMT 20/ 2/2023 6:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 31 15.22 497 234 0.23 / 48.49 5 7
2 7 2002.92 40 14.86 3174 1887 2.12 / 50.37 11 20
3 13 1313.44 20 14.97 2274 681 2.80 / 51.05 5 29
4 13 830.64 20 15.07 1616 487 3.29 / 51.54 5 31
5 13 125.04 20 15.27 566 173 3.46 / 51.71 5 27
6 8 0.12 291 15.23 350 1551 5.01 / 53.26 5 134
Average= 4.44
(KJ/cycle)

Cycle 10 GMT 10/ 2/2023 0:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 30 15.23 479 219 0.22 / 43.41 5 6
2 3 1030.52 1 15.29 1866 29 0.25 / 43.44 5 14
3 7 2013.84 40 14.87 3204 1906 2.15 / 45.35 14 19
4 13 1347.32 20 14.97 2319 694 2.85 / 46.04 5 29
5 13 685.40 20 15.12 1393 421 3.27 / 46.46 5 31
6 13 208.36 20 15.24 694 212 3.48 / 46.67 5 29
7 13 20.88 20 15.29 399 122 3.60 / 46.79 5 26
8 8 0.00 274 15.23 349 1456 5.06 / 48.25 5 147
Average= 4.39
(KJ/cycle)

Cycle 9 GMT 30/ 1/2023 18: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 30 15.24 476 218 0.22 / 38.39 5 6
2 7 2010.12 40 14.87 3205 1906 2.12 / 40.30 6 20
3 13 1421.96 20 14.95 2418 723 2.85 / 41.02 5 27
4 13 714.28 20 15.12 1429 432 3.28 / 41.45 5 30
5 13 144.00 20 15.27 591 180 3.46 / 41.63 5 27
6 8 0.16 295 15.24 347 1560 5.02 / 43.19 5 158
Average= 4.32
(KJ/cycle)

Cycle 8 GMT 20/ 1/2023 11:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.60 30 15.24 482 220 0.22 / 33.37 5 6
2 3 1020.68 1 15.30 1822 28 0.25 / 33.40 5 14
3 7 2011.04 40 14.87 3186 1895 2.14 / 35.29 14 21
4 13 1420.56 20 14.96 2409 721 2.86 / 36.02 5 30
5 13 711.20 20 15.12 1421 430 3.29 / 36.45 5 32
6 13 147.40 20 15.27 597 182 3.48 / 36.63 5 29
7 13 34.24 20 15.30 413 126 3.60 / 36.75 5 26
8 8 0.04 272 15.25 342 1419 5.02 / 38.17 5 140
Average= 4.24
(KJ/cycle)

Cycle 7 GMT 10/ 1/2023 5: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 30 15.25 474 217 0.22 / 28.28 5 6
2 7 2007.80 40 14.87 3187 1896 2.11 / 30.18 8 21
3 13 1438.36 20 14.95 2444 731 2.84 / 30.91 5 29
4 13 745.80 20 15.12 1476 446 3.29 / 31.35 5 31
5 13 161.88 20 15.27 622 190 3.48 / 31.54 5 29
6 13 41.32 20 15.29 434 133 3.61 / 31.68 5 27
7 8 0.04 274 15.24 353 1474 5.09 / 33.15 5 144
Average= 4.14
(KJ/cycle)

Cycle 6 GMT 30/12/2022 22:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 29 15.25 483 214 0.21 / 23.35 5 6
2 3 1044.84 1 15.28 1891 29 0.24 / 23.38 5 17
3 7 2007.72 40 14.87 3183 1893 2.14 / 25.27 17 20
4 13 1319.16 20 14.99 2272 681 2.82 / 25.95 5 29
5 13 636.60 20 15.15 1324 401 3.22 / 26.35 5 30
6 13 102.20 20 15.29 522 160 3.38 / 26.51 5 27
7 13 27.84 20 15.30 399 122 3.50 / 26.63 5 26
8 8 0.12 272 15.25 345 1431 4.93 / 28.07 5 137
Average= 4.01
(KJ/cycle)

Cycle 5 GMT 20/12/2022 15:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 31 15.26 491 232 0.23 / 18.39 5 6
2 3 910.88 -1 15.58 0 0 0.00 / 18.39 5 6
3 7 2004.40 40 14.88 3184 1895 2.13 / 20.28 6 21
4 13 1317.48 20 15.00 2254 676 2.80 / 20.96 5 29
5 13 632.72 20 15.16 1318 400 3.20 / 21.36 5 31
6 13 154.80 20 15.28 618 189 3.39 / 21.55 5 29
7 13 38.80 20 15.30 432 132 3.52 / 21.68 5 27
8 8 0.04 272 15.26 351 1457 4.98 / 23.13 5 144
Average= 3.86
(KJ/cycle)

Cycle 4 GMT 10/12/2022 8:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.68 27 15.26 490 202 0.20 / 13.77 5 6
2 10 1024.24 4 15.25 1807 110 0.31 / 13.88 5 11
3 7 1511.40 40 15.09 2504 1511 1.82 / 15.39 11 18
4 13 1202.84 20 15.10 2099 634 2.46 / 16.03 5 23
5 13 624.96 20 15.20 1290 392 2.85 / 16.42 5 28
6 13 130.00 20 15.31 568 174 3.02 / 16.59 5 27
7 13 29.16 20 15.33 409 125 3.15 / 16.72 5 26
8 8 -0.04 270 15.28 348 1436 4.58 / 18.15 5 142
Average= 3.63
(KJ/cycle)

Cycle 3 GMT 8/12/2022 23:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 25 15.25 498 190 0.19 / 9.33 5 6
2 10 1032.04 3 15.24 1856 85 0.27 / 9.41 5 13
3 3 942.64 -1 15.57 0 0 0.08 / 9.41 5 13
4 7 1511.64 40 15.09 2509 1514 1.79 / 10.92 13 19
5 13 1111.56 20 15.11 1974 597 2.39 / 11.52 5 25
6 13 532.56 20 15.22 1166 355 2.74 / 11.88 5 28
7 13 92.32 20 15.32 522 160 2.90 / 12.04 5 26
8 8 0.04 289 15.28 347 1532 4.43 / 13.57 5 149
Average= 3.39
(KJ/cycle)

Cycle 2 GMT 7/12/2022 13:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.48 31 15.26 493 233 0.23 / 5.01 5 6
2 3 835.68 -3 15.58 0 0 0.00 / 5.01 5 6
3 7 1509.80 41 15.10 2485 1538 1.77 / 6.55 6 19
4 13 1101.68 20 15.12 1951 590 2.36 / 7.14 5 25
5 13 521.40 20 15.22 1137 346 2.71 / 7.49 5 27
6 13 86.12 20 15.31 496 152 2.86 / 7.64 5 26
7 8 0.04 287 15.27 341 1494 4.35 / 9.14 5 132
Average= 3.05
(KJ/cycle)

Cycle 1 GMT 6/12/2022 3:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 31 15.45 449 215 0.22 / 2.04 5 6
2 3 824.56 -3 15.59 0 0 0.00 / 2.04 5 6
3 7 927.68 40 15.24 1677 1022 1.24 / 3.06 6 20
4 13 153.00 20 15.36 593 182 1.42 / 3.25 5 24
5 13 18.68 20 15.38 379 117 1.54 / 3.36 5 23
6 8 -0.04 272 15.31 341 1420 2.96 / 4.78 5 133
Average= 2.39
(KJ/cycle)

Cycle 0 GMT 5/12/2022 17:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 93.80 30 15.63 407 191 0.19 / 0.19 5 6
2 7 109.40 40 15.61 422 263 0.45 / 0.45 6 7
3 13 78.04 20 15.59 379 118 0.57 / 0.57 5 8
4 13 18.32 20 15.58 294 92 0.66 / 0.66 5 8
5 8 0.12 270 15.53 277 1161 1.83 / 1.83 5 148
Average= 1.83
(KJ/cycle)