SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.48 | 32 | 15.16 | 403 | 196 | 0.20 / 103.01 | 6 | 9 |
2 | 7 | 2003.04 | 40 | 14.78 | 2563 | 1515 | 1.71 / 104.52 | 9 | 23 |
3 | 13 | 1266.52 | 20 | 14.92 | 1740 | 519 | 2.23 / 105.04 | 6 | 32 |
4 | 13 | 701.08 | 20 | 15.04 | 1099 | 331 | 2.56 / 105.37 | 6 | 36 |
5 | 13 | 51.00 | 20 | 15.23 | 342 | 104 | 2.66 / 105.48 | 6 | 29 |
6 | 8 | -0.04 | 308 | 15.18 | 275 | 1286 | 3.95 / 106.76 | 6 | 136 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.24 | 32 | 15.16 | 401 | 195 | 0.19 / 98.97 | 6 | 9 |
2 | 7 | 2002.72 | 40 | 14.79 | 2566 | 1518 | 1.71 / 100.49 | 9 | 23 |
3 | 13 | 1304.08 | 20 | 14.91 | 1794 | 535 | 2.25 / 101.02 | 6 | 31 |
4 | 13 | 833.76 | 20 | 15.00 | 1263 | 379 | 2.63 / 101.40 | 6 | 36 |
5 | 13 | 52.48 | 20 | 15.24 | 346 | 105 | 2.73 / 101.51 | 6 | 30 |
6 | 8 | 0.16 | 310 | 15.18 | 277 | 1304 | 4.04 / 102.81 | 6 | 138 |
Average= | 3.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.56 | 31 | 15.16 | 399 | 188 | 0.19 / 94.89 | 6 | 9 |
2 | 7 | 2004.36 | 40 | 14.78 | 2572 | 1521 | 1.71 / 96.41 | 9 | 23 |
3 | 13 | 1393.88 | 20 | 14.90 | 1888 | 563 | 2.27 / 96.98 | 6 | 31 |
4 | 13 | 812.48 | 20 | 15.01 | 1232 | 370 | 2.64 / 97.35 | 6 | 36 |
5 | 13 | 87.12 | 20 | 15.23 | 387 | 118 | 2.76 / 97.46 | 6 | 31 |
6 | 8 | 0.08 | 310 | 15.18 | 279 | 1313 | 4.07 / 98.78 | 6 | 148 |
Average= | 3.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.92 | 31 | 15.16 | 396 | 186 | 0.19 / 90.84 | 6 | 9 |
2 | 7 | 2009.60 | 40 | 14.79 | 2579 | 1526 | 1.71 / 92.37 | 9 | 24 |
3 | 13 | 1437.40 | 20 | 14.89 | 1944 | 579 | 2.29 / 92.95 | 6 | 30 |
4 | 13 | 731.04 | 20 | 15.04 | 1141 | 343 | 2.63 / 93.29 | 6 | 36 |
5 | 13 | 61.24 | 20 | 15.24 | 351 | 107 | 2.74 / 93.40 | 6 | 30 |
6 | 8 | -0.20 | 310 | 15.19 | 278 | 1309 | 4.05 / 94.71 | 6 | 146 |
Average= | 3.79 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.44 | 31 | 15.17 | 385 | 181 | 0.18 / 86.86 | 6 | 9 |
2 | 7 | 2003.16 | 40 | 14.78 | 2566 | 1517 | 1.70 / 88.37 | 9 | 23 |
3 | 13 | 1295.16 | 20 | 14.92 | 1773 | 529 | 2.23 / 88.90 | 6 | 32 |
4 | 13 | 720.68 | 20 | 15.04 | 1126 | 339 | 2.57 / 89.24 | 6 | 37 |
5 | 13 | 55.12 | 20 | 15.24 | 344 | 105 | 2.67 / 89.35 | 6 | 30 |
6 | 8 | 0.08 | 308 | 15.19 | 280 | 1310 | 3.98 / 90.66 | 6 | 150 |
Average= | 3.78 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.24 | 31 | 15.16 | 398 | 187 | 0.19 / 82.77 | 6 | 9 |
2 | 7 | 2003.64 | 40 | 14.79 | 2565 | 1517 | 1.70 / 84.29 | 9 | 23 |
3 | 13 | 1400.32 | 20 | 14.91 | 1889 | 563 | 2.27 / 84.85 | 6 | 31 |
4 | 13 | 922.60 | 20 | 14.99 | 1358 | 407 | 2.67 / 85.26 | 6 | 36 |
5 | 13 | 65.96 | 20 | 15.24 | 358 | 109 | 2.78 / 85.37 | 6 | 31 |
6 | 8 | 0.12 | 308 | 15.19 | 280 | 1310 | 4.09 / 86.68 | 6 | 138 |
Average= | 3.77 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.48 | 31 | 15.18 | 390 | 184 | 0.18 / 78.79 | 6 | 9 |
2 | 7 | 2016.48 | 40 | 14.79 | 2584 | 1529 | 1.71 / 80.32 | 9 | 23 |
3 | 13 | 1193.28 | 20 | 14.95 | 1660 | 496 | 2.21 / 80.82 | 6 | 33 |
4 | 13 | 761.20 | 20 | 15.03 | 1178 | 354 | 2.56 / 81.17 | 6 | 36 |
5 | 13 | 49.36 | 20 | 15.24 | 343 | 105 | 2.67 / 81.28 | 6 | 32 |
6 | 8 | 0.12 | 306 | 15.19 | 281 | 1306 | 3.97 / 82.58 | 6 | 135 |
Average= | 3.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.56 | 31 | 15.18 | 384 | 181 | 0.18 / 74.77 | 6 | 9 |
2 | 7 | 2003.96 | 40 | 14.80 | 2564 | 1518 | 1.70 / 76.29 | 9 | 23 |
3 | 13 | 1287.36 | 20 | 14.94 | 1770 | 529 | 2.23 / 76.82 | 6 | 31 |
4 | 13 | 825.44 | 20 | 15.02 | 1243 | 373 | 2.60 / 77.19 | 6 | 36 |
5 | 13 | 55.16 | 20 | 15.25 | 345 | 105 | 2.71 / 77.30 | 6 | 29 |
6 | 8 | 0.08 | 310 | 15.20 | 278 | 1310 | 4.02 / 78.61 | 6 | 148 |
Average= | 3.74 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.60 | 31 | 15.18 | 395 | 186 | 0.19 / 70.71 | 6 | 8 |
2 | 7 | 2007.76 | 41 | 14.80 | 2570 | 1559 | 1.75 / 72.27 | 8 | 23 |
3 | 13 | 1384.40 | 20 | 14.92 | 1875 | 559 | 2.30 / 72.83 | 6 | 31 |
4 | 13 | 765.12 | 20 | 15.05 | 1176 | 354 | 2.66 / 73.19 | 6 | 36 |
5 | 13 | 66.80 | 20 | 15.25 | 358 | 109 | 2.77 / 73.30 | 6 | 30 |
6 | 8 | 0.12 | 308 | 15.20 | 277 | 1297 | 4.06 / 74.59 | 6 | 144 |
Average= | 3.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 118.52 | 31 | 15.19 | 402 | 189 | 0.19 / 66.71 | 6 | 8 |
2 | 7 | 2004.92 | 40 | 14.80 | 2566 | 1519 | 1.71 / 68.23 | 8 | 23 |
3 | 13 | 1279.72 | 20 | 14.94 | 1760 | 526 | 2.23 / 68.76 | 6 | 31 |
4 | 13 | 804.68 | 20 | 15.03 | 1224 | 368 | 2.60 / 69.13 | 6 | 36 |
5 | 13 | 44.08 | 20 | 15.26 | 335 | 102 | 2.70 / 69.23 | 6 | 30 |
6 | 8 | -0.12 | 306 | 15.20 | 279 | 1298 | 4.00 / 70.53 | 6 | 130 |
Average= | 3.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.48 | 31 | 15.19 | 389 | 183 | 0.18 / 62.74 | 6 | 8 |
2 | 7 | 2006.64 | 40 | 14.81 | 2572 | 1524 | 1.71 / 64.26 | 8 | 23 |
3 | 13 | 1298.36 | 20 | 14.94 | 1781 | 532 | 2.24 / 64.80 | 6 | 31 |
4 | 13 | 733.00 | 20 | 15.06 | 1134 | 342 | 2.58 / 65.14 | 6 | 36 |
5 | 13 | 53.60 | 20 | 15.26 | 339 | 103 | 2.68 / 65.24 | 6 | 30 |
6 | 8 | 0.32 | 308 | 15.21 | 274 | 1284 | 3.97 / 66.52 | 6 | 140 |
Average= | 3.70 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 31 | 15.19 | 395 | 186 | 0.19 / 58.81 | 6 | 9 |
2 | 7 | 2006.68 | 41 | 14.81 | 2564 | 1557 | 1.74 / 60.37 | 9 | 23 |
3 | 13 | 1204.76 | 20 | 14.97 | 1664 | 498 | 2.24 / 60.87 | 6 | 32 |
4 | 13 | 656.76 | 20 | 15.09 | 1042 | 314 | 2.56 / 61.18 | 6 | 37 |
5 | 13 | 44.28 | 20 | 15.27 | 322 | 98 | 2.65 / 61.28 | 6 | 30 |
6 | 8 | -0.04 | 310 | 15.21 | 271 | 1278 | 3.93 / 62.56 | 6 | 153 |
Average= | 3.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.80 | 31 | 15.19 | 386 | 182 | 0.18 / 54.83 | 6 | 9 |
2 | 7 | 2005.60 | 40 | 14.81 | 2567 | 1521 | 1.70 / 56.35 | 9 | 23 |
3 | 13 | 1196.24 | 20 | 14.97 | 1673 | 501 | 2.20 / 56.85 | 6 | 32 |
4 | 13 | 861.36 | 20 | 15.03 | 1282 | 385 | 2.59 / 57.24 | 6 | 36 |
5 | 13 | 54.20 | 20 | 15.27 | 335 | 102 | 2.69 / 57.34 | 6 | 30 |
6 | 8 | 0.04 | 312 | 15.21 | 271 | 1286 | 3.98 / 58.63 | 6 | 154 |
Average= | 3.66 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.92 | 31 | 15.19 | 391 | 184 | 0.18 / 50.85 | 6 | 9 |
2 | 7 | 2003.48 | 40 | 14.82 | 2558 | 1516 | 1.70 / 52.37 | 9 | 23 |
3 | 13 | 1385.44 | 20 | 14.93 | 1886 | 563 | 2.26 / 52.93 | 6 | 31 |
4 | 13 | 721.28 | 20 | 15.08 | 1119 | 337 | 2.60 / 53.27 | 6 | 36 |
5 | 13 | 22.24 | 20 | 15.28 | 305 | 93 | 2.69 / 53.36 | 6 | 30 |
6 | 8 | 0.16 | 310 | 15.22 | 273 | 1288 | 3.98 / 54.65 | 6 | 145 |
Average= | 3.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.12 | 31 | 15.19 | 403 | 190 | 0.19 / 46.89 | 6 | 10 |
2 | 7 | 2006.40 | 40 | 14.81 | 2575 | 1525 | 1.72 / 48.42 | 10 | 23 |
3 | 13 | 1293.96 | 20 | 14.96 | 1771 | 530 | 2.25 / 48.95 | 6 | 32 |
4 | 13 | 718.84 | 20 | 15.08 | 1123 | 339 | 2.58 / 49.29 | 6 | 36 |
5 | 13 | 42.56 | 20 | 15.27 | 327 | 100 | 2.68 / 49.39 | 6 | 30 |
6 | 8 | 0.04 | 306 | 15.22 | 275 | 1281 | 3.96 / 50.67 | 6 | 131 |
Average= | 3.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 116.12 | 31 | 15.19 | 407 | 192 | 0.19 / 42.84 | 6 | 10 |
2 | 7 | 2008.08 | 40 | 14.82 | 2567 | 1522 | 1.71 / 44.36 | 6 | 24 |
3 | 13 | 1380.08 | 20 | 14.95 | 1867 | 558 | 2.27 / 44.92 | 6 | 31 |
4 | 13 | 883.12 | 20 | 15.04 | 1306 | 393 | 2.66 / 45.31 | 6 | 36 |
5 | 13 | 28.12 | 20 | 15.28 | 309 | 94 | 2.76 / 45.40 | 6 | 30 |
6 | 8 | 0.12 | 308 | 15.22 | 277 | 1299 | 4.06 / 46.70 | 6 | 147 |
Average= | 3.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.72 | 31 | 15.20 | 380 | 179 | 0.18 / 38.86 | 6 | 10 |
2 | 7 | 2006.88 | 40 | 14.83 | 2575 | 1527 | 1.71 / 40.39 | 10 | 24 |
3 | 13 | 1300.00 | 20 | 14.96 | 1790 | 536 | 2.24 / 40.92 | 6 | 32 |
4 | 13 | 734.32 | 20 | 15.07 | 1143 | 345 | 2.59 / 41.27 | 6 | 37 |
5 | 13 | 51.44 | 20 | 15.27 | 339 | 104 | 2.69 / 41.37 | 6 | 31 |
6 | 8 | 0.00 | 304 | 15.22 | 275 | 1272 | 3.96 / 42.64 | 6 | 145 |
Average= | 3.55 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.32 | 31 | 15.19 | 393 | 185 | 0.19 / 34.94 | 6 | 10 |
2 | 7 | 2004.36 | 40 | 14.83 | 2567 | 1523 | 1.71 / 36.46 | 6 | 24 |
3 | 13 | 1282.08 | 20 | 14.97 | 1752 | 525 | 2.23 / 36.98 | 6 | 32 |
4 | 13 | 686.64 | 20 | 15.09 | 1083 | 327 | 2.56 / 37.31 | 6 | 37 |
5 | 13 | 33.76 | 20 | 15.28 | 320 | 98 | 2.66 / 37.41 | 6 | 32 |
6 | 8 | 0.12 | 304 | 15.23 | 275 | 1273 | 3.93 / 38.68 | 6 | 139 |
Average= | 3.52 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 31 | 15.20 | 390 | 184 | 0.18 / 30.96 | 6 | 9 |
2 | 7 | 2005.32 | 41 | 14.83 | 2570 | 1563 | 1.75 / 32.52 | 9 | 24 |
3 | 13 | 1197.52 | 20 | 14.99 | 1660 | 498 | 2.24 / 33.02 | 6 | 33 |
4 | 13 | 737.64 | 20 | 15.08 | 1142 | 344 | 2.59 / 33.37 | 6 | 37 |
5 | 13 | 47.64 | 20 | 15.28 | 337 | 103 | 2.69 / 33.47 | 6 | 32 |
6 | 8 | -0.16 | 302 | 15.22 | 279 | 1282 | 3.97 / 34.75 | 6 | 137 |
Average= | 3.48 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.72 | 31 | 15.20 | 395 | 186 | 0.19 / 27.01 | 6 | 10 |
2 | 7 | 2003.64 | 40 | 14.84 | 2570 | 1526 | 1.71 / 28.53 | 10 | 23 |
3 | 13 | 1272.72 | 20 | 14.98 | 1750 | 524 | 2.24 / 29.06 | 6 | 31 |
4 | 13 | 705.96 | 20 | 15.09 | 1111 | 335 | 2.57 / 29.39 | 6 | 36 |
5 | 13 | 45.04 | 20 | 15.28 | 335 | 102 | 2.67 / 29.49 | 6 | 30 |
6 | 8 | 0.04 | 302 | 15.23 | 279 | 1283 | 3.96 / 30.78 | 6 | 136 |
Average= | 3.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.84 | 31 | 15.20 | 408 | 192 | 0.19 / 23.05 | 6 | 11 |
2 | 7 | 2006.32 | 41 | 14.84 | 2567 | 1562 | 1.75 / 24.61 | 11 | 22 |
3 | 13 | 1194.96 | 20 | 15.00 | 1660 | 498 | 2.25 / 25.11 | 6 | 31 |
4 | 13 | 737.56 | 20 | 15.08 | 1147 | 346 | 2.60 / 25.45 | 6 | 36 |
5 | 8 | 0.12 | 321 | 15.23 | 280 | 1369 | 3.97 / 26.82 | 6 | 141 |
Average= | 3.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 117.68 | 31 | 15.20 | 408 | 192 | 0.19 / 19.09 | 6 | 12 |
2 | 7 | 2005.00 | 40 | 14.85 | 2571 | 1527 | 1.72 / 20.61 | 6 | 23 |
3 | 13 | 1379.16 | 20 | 14.96 | 1872 | 560 | 2.28 / 21.17 | 6 | 31 |
4 | 13 | 676.24 | 20 | 15.11 | 1077 | 325 | 2.60 / 21.50 | 6 | 37 |
5 | 8 | 0.48 | 319 | 15.23 | 279 | 1355 | 3.96 / 22.85 | 6 | 135 |
Average= | 3.26 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.60 | 31 | 15.21 | 403 | 190 | 0.19 / 15.14 | 6 | 12 |
2 | 7 | 2005.00 | 40 | 14.86 | 2569 | 1527 | 1.72 / 16.67 | 12 | 24 |
3 | 13 | 1205.96 | 20 | 15.00 | 1675 | 502 | 2.22 / 17.17 | 6 | 32 |
4 | 13 | 743.28 | 20 | 15.09 | 1148 | 346 | 2.57 / 17.52 | 6 | 37 |
5 | 8 | 0.24 | 319 | 15.23 | 283 | 1375 | 3.94 / 18.89 | 6 | 140 |
Average= | 3.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.88 | 30 | 15.21 | 394 | 180 | 0.18 / 11.58 | 6 | 11 |
2 | 7 | 1521.16 | 40 | 15.01 | 2033 | 1221 | 1.40 / 12.80 | 11 | 27 |
3 | 13 | 1191.36 | 20 | 15.05 | 1658 | 499 | 1.90 / 13.30 | 6 | 32 |
4 | 13 | 590.68 | 20 | 15.17 | 976 | 296 | 2.20 / 13.60 | 6 | 37 |
5 | 8 | 0.04 | 317 | 15.26 | 280 | 1354 | 3.55 / 14.95 | 6 | 140 |
Average= | 2.99 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.60 | 30 | 15.21 | 411 | 188 | 0.19 / 7.97 | 6 | 10 |
2 | 3 | 1019.44 | 1 | 15.23 | 1483 | 23 | 0.21 / 8.00 | 6 | 8 |
3 | 7 | 1524.72 | 40 | 15.01 | 2037 | 1223 | 1.43 / 9.22 | 8 | 26 |
4 | 13 | 1210.72 | 20 | 15.04 | 1691 | 509 | 1.94 / 9.73 | 6 | 32 |
5 | 13 | 622.96 | 20 | 15.16 | 1013 | 307 | 2.25 / 10.04 | 6 | 37 |
6 | 8 | 0.08 | 319 | 15.25 | 281 | 1367 | 3.62 / 11.40 | 6 | 136 |
Average= | 2.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.80 | 31 | 15.25 | 397 | 188 | 0.19 / 4.37 | 6 | 10 |
2 | 3 | 958.60 | -1 | 15.56 | 15 | 0 | 0.00 / 4.37 | 6 | 10 |
3 | 7 | 1524.40 | 40 | 15.01 | 2042 | 1226 | 1.41 / 5.60 | 10 | 27 |
4 | 13 | 1310.88 | 20 | 15.03 | 1795 | 540 | 1.95 / 6.14 | 6 | 31 |
5 | 13 | 597.32 | 20 | 15.16 | 980 | 297 | 2.25 / 6.43 | 6 | 37 |
6 | 8 | 0.24 | 319 | 15.25 | 278 | 1352 | 3.60 / 7.79 | 6 | 135 |
Average= | 2.60 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 31 | 15.38 | 378 | 180 | 0.18 / 1.92 | 6 | 9 |
2 | 3 | 957.60 | -1 | 15.58 | 15 | 0 | 0.00 / 1.92 | 6 | 9 |
3 | 7 | 998.76 | 41 | 15.14 | 1439 | 893 | 1.07 / 2.82 | 9 | 33 |
4 | 8 | 0.08 | 321 | 15.31 | 278 | 1366 | 2.44 / 4.18 | 6 | 136 |
Average= | 2.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 129.24 | 30 | 15.56 | 415 | 194 | 0.19 / 0.19 | 6 | 10 |
2 | 7 | 142.24 | 40 | 15.53 | 419 | 260 | 0.45 / 0.45 | 10 | 12 |
3 | 8 | 0.12 | 327 | 15.47 | 255 | 1290 | 1.74 / 1.74 | 6 | 169 |
Average= | 1.74 (KJ/cycle) |