SIO Argo Site:
Pump Diagnostics Page   



Serial= 7783 WMO= 1902479

Return

←PreviousNext→

Cycle 34 GMT 11/ 5/2024 14:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 32 15.14 415 201 0.20 / 153.11 6 6
2 7 2004.08 40 14.77 3194 1887 2.09 / 155.00 6 9
3 13 1558.28 20 14.82 2535 751 2.84 / 155.75 5 14
4 13 859.48 20 14.98 1538 461 3.30 / 156.21 5 19
5 13 274.24 20 15.12 712 215 3.52 / 156.43 5 18
6 13 78.60 20 15.17 424 129 3.64 / 156.55 5 16
7 13 51.20 20 15.17 378 115 3.76 / 156.67 5 17
8 8 0.08 244 15.13 301 1111 4.87 / 157.78 5 153
Average= 4.51
(KJ/cycle)

Cycle 33 GMT 1/ 5/2024 8: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 32 15.14 409 198 0.20 / 148.47 6 6
2 7 2011.64 40 14.77 3196 1888 2.09 / 150.36 6 9
3 13 1359.32 20 14.88 2242 667 2.75 / 151.02 5 16
4 13 816.32 20 14.99 1480 444 3.20 / 151.47 5 19
5 13 160.32 20 15.16 561 170 3.37 / 151.64 5 16
6 13 66.16 20 15.18 409 124 3.49 / 151.76 5 13
7 13 43.36 20 15.18 366 111 3.60 / 151.87 5 13
8 8 0.04 244 15.14 281 1038 4.64 / 152.91 5 165
Average= 4.50
(KJ/cycle)

Cycle 32 GMT 21/ 4/2024 1:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 32 15.14 414 201 0.20 / 143.75 6 6
2 7 2015.16 40 14.79 3142 1859 2.06 / 145.61 6 9
3 13 1560.12 20 14.83 2560 759 2.82 / 146.37 5 15
4 13 769.96 20 15.01 1406 422 3.24 / 146.79 5 19
5 13 209.08 20 15.15 634 192 3.43 / 146.99 5 17
6 13 76.04 20 15.18 424 129 3.56 / 147.12 5 15
7 13 52.60 20 15.18 382 116 3.68 / 147.23 5 14
8 8 0.12 244 15.15 281 1039 4.72 / 148.27 5 147
Average= 4.49
(KJ/cycle)

Cycle 31 GMT 10/ 4/2024 19: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 32 15.14 428 207 0.21 / 138.94 6 6
2 7 2014.12 40 14.79 3162 1871 2.08 / 140.81 6 9
3 13 1568.44 20 14.83 2581 766 2.84 / 141.58 5 14
4 13 856.24 20 14.99 1527 458 3.30 / 142.04 5 20
5 13 270.40 20 15.13 720 218 3.52 / 142.25 5 20
6 13 80.20 20 15.18 434 132 3.65 / 142.39 5 17
7 13 52.32 20 15.18 379 115 3.77 / 142.50 5 15
8 8 0.04 244 15.15 285 1054 4.82 / 143.55 5 150
Average= 4.49
(KJ/cycle)

Cycle 30 GMT 31/ 3/2024 12:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.32 32 15.14 430 208 0.21 / 134.04 6 6
2 7 2015.24 40 14.78 3214 1900 2.11 / 135.94 6 9
3 13 1449.24 20 14.85 2429 721 2.83 / 136.66 5 16
4 13 881.36 20 14.98 1612 483 3.31 / 137.15 5 20
5 13 196.36 20 15.15 637 193 3.51 / 137.34 5 18
6 13 68.12 20 15.19 423 129 3.63 / 137.47 5 15
7 13 47.24 20 15.18 392 119 3.75 / 137.59 5 16
8 8 0.16 244 15.15 310 1146 4.90 / 138.73 5 172
Average= 4.48
(KJ/cycle)

Cycle 29 GMT 21/ 3/2024 6:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 32 15.15 410 199 0.20 / 129.31 6 6
2 7 2011.28 40 14.79 3172 1877 2.08 / 131.19 6 9
3 13 1454.08 20 14.87 2375 706 2.78 / 131.89 5 16
4 13 774.76 20 15.02 1419 426 3.21 / 132.32 5 20
5 13 197.28 20 15.16 612 186 3.39 / 132.50 5 20
6 13 71.48 20 15.19 412 125 3.52 / 132.63 5 15
7 13 41.92 20 15.19 366 111 3.63 / 132.74 5 14
8 8 0.00 244 15.16 296 1095 4.72 / 133.83 5 176
Average= 4.46
(KJ/cycle)

Cycle 28 GMT 11/ 3/2024 0: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 32 15.15 426 207 0.21 / 124.60 6 6
2 7 2003.88 41 14.79 3152 1911 2.12 / 126.51 6 10
3 13 1447.36 20 14.87 2367 704 2.82 / 127.21 5 16
4 13 774.72 20 15.03 1418 426 3.25 / 127.64 5 20
5 13 213.08 20 15.16 632 192 3.44 / 127.83 5 19
6 13 55.48 20 15.20 391 119 3.56 / 127.95 5 16
7 13 35.96 20 15.20 354 108 3.67 / 128.06 5 18
8 8 0.00 242 15.16 287 1053 4.72 / 129.11 5 165
Average= 4.45
(KJ/cycle)

Cycle 27 GMT 29/ 2/2024 17:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 32 15.15 455 221 0.22 / 119.90 6 6
2 7 2017.08 40 14.80 3155 1868 2.09 / 121.77 6 10
3 13 1455.96 20 14.88 2393 712 2.80 / 122.48 5 16
4 13 795.04 20 15.02 1457 438 3.24 / 122.92 5 20
5 13 222.76 20 15.16 649 197 3.43 / 123.11 5 20
6 13 60.84 20 15.20 399 121 3.56 / 123.24 5 16
7 13 21.28 20 15.21 330 100 3.66 / 123.34 5 17
8 8 0.08 244 15.17 285 1055 4.71 / 124.39 5 162
Average= 4.44
(KJ/cycle)

Cycle 26 GMT 19/ 2/2024 11:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 32 15.16 430 209 0.21 / 115.06 6 6
2 7 2014.24 40 14.79 3202 1894 2.10 / 116.95 6 9
3 13 1461.44 20 14.88 2398 714 2.82 / 117.66 5 17
4 13 888.16 20 15.00 1580 474 3.29 / 118.14 5 20
5 13 200.28 20 15.18 619 188 3.48 / 118.33 5 18
6 13 65.00 20 15.21 405 123 3.60 / 118.45 5 15
7 13 38.48 20 15.21 355 108 3.71 / 118.56 5 16
8 8 0.08 244 15.17 303 1122 4.83 / 119.68 5 154
Average= 4.43
(KJ/cycle)

Cycle 25 GMT 9/ 2/2024 4:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 32 15.17 414 201 0.20 / 110.21 6 6
2 7 2007.12 41 14.81 3141 1907 2.11 / 112.12 6 9
3 13 1533.72 20 14.87 2512 747 2.86 / 112.86 5 16
4 13 923.76 20 15.00 1623 487 3.34 / 113.35 5 20
5 13 223.60 20 15.18 652 198 3.54 / 113.55 5 17
6 13 57.12 20 15.22 395 120 3.66 / 113.67 5 14
7 13 21.36 20 15.22 326 99 3.76 / 113.77 5 14
8 8 0.08 244 15.18 292 1082 4.84 / 114.85 5 182
Average= 4.42
(KJ/cycle)

Cycle 24 GMT 29/ 1/2024 22:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 32 15.17 420 204 0.20 / 105.48 6 6
2 7 2006.76 41 14.80 3154 1914 2.12 / 107.39 6 9
3 13 1452.72 20 14.87 2424 721 2.84 / 108.11 5 16
4 13 777.04 20 15.04 1427 429 3.27 / 108.54 5 20
5 13 209.64 20 15.18 630 191 3.46 / 108.73 5 18
6 13 63.16 20 15.22 403 123 3.58 / 108.85 5 15
7 13 40.72 20 15.21 360 110 3.69 / 108.96 5 16
8 8 0.08 242 15.18 284 1043 4.73 / 110.01 5 171
Average= 4.40
(KJ/cycle)

Cycle 23 GMT 19/ 1/2024 16:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 32 15.17 442 215 0.21 / 100.68 6 6
2 7 2004.56 40 14.80 3186 1886 2.10 / 102.56 6 10
3 13 1534.60 20 14.86 2531 752 2.85 / 103.32 5 16
4 13 819.92 20 15.03 1497 450 3.30 / 103.77 5 20
5 13 239.32 20 15.18 671 204 3.51 / 103.97 5 19
6 13 64.56 20 15.22 417 127 3.63 / 104.10 5 17
7 13 47.40 20 15.22 376 114 3.75 / 104.21 5 17
8 8 0.04 242 15.18 289 1062 4.81 / 105.27 5 159
Average= 4.39
(KJ/cycle)

Cycle 22 GMT 9/ 1/2024 9:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.64 32 15.17 451 219 0.22 / 95.82 6 6
2 7 2011.84 40 14.81 3184 1886 2.11 / 97.71 6 11
3 13 1470.56 20 14.89 2438 726 2.83 / 98.43 5 18
4 13 794.20 20 15.05 1469 442 3.27 / 98.88 5 21
5 13 223.28 20 15.18 668 203 3.48 / 99.08 5 18
6 13 59.52 20 15.22 415 126 3.60 / 99.21 5 18
7 13 35.88 20 15.22 379 115 3.72 / 99.32 5 18
8 8 0.08 242 15.18 311 1142 4.86 / 100.46 5 143
Average= 4.37
(KJ/cycle)

Cycle 21 GMT 30/12/2023 3:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 32 15.17 446 217 0.22 / 90.95 6 6
2 7 2014.72 40 14.81 3189 1889 2.11 / 92.84 6 12
3 13 1468.52 20 14.90 2401 715 2.82 / 93.55 5 19
4 13 891.40 20 15.02 1581 475 3.30 / 94.03 5 22
5 13 189.56 20 15.20 598 182 3.48 / 94.21 5 20
6 13 52.64 20 15.23 397 121 3.60 / 94.33 5 18
7 13 34.68 20 15.22 378 115 3.71 / 94.45 5 18
8 8 0.08 242 15.18 315 1157 4.87 / 95.60 5 170
Average= 4.35
(KJ/cycle)

Cycle 20 GMT 19/12/2023 21:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 32 15.19 405 197 0.20 / 86.15 6 6
2 7 2012.48 40 14.82 3183 1887 2.08 / 88.04 6 11
3 13 1347.72 20 14.92 2293 684 2.77 / 88.72 5 18
4 13 783.68 20 15.05 1450 436 3.20 / 89.16 5 22
5 13 115.44 20 15.22 515 157 3.36 / 89.32 5 20
6 13 63.56 20 15.23 438 133 3.49 / 89.45 5 18
7 13 40.64 20 15.22 396 121 3.62 / 89.57 5 20
8 8 0.04 240 15.18 319 1162 4.78 / 90.73 5 137
Average= 4.32
(KJ/cycle)

Cycle 19 GMT 9/12/2023 14:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 32 15.19 431 210 0.21 / 81.57 6 6
2 7 2015.52 40 14.82 3153 1869 2.08 / 83.44 6 11
3 13 1363.68 20 14.94 2242 670 2.75 / 84.11 5 18
4 13 723.56 20 15.08 1342 405 3.15 / 84.51 5 22
5 13 162.96 20 15.21 559 170 3.32 / 84.68 5 21
6 13 58.00 20 15.24 394 120 3.44 / 84.80 5 17
7 13 38.96 20 15.24 360 110 3.55 / 84.91 5 18
8 8 0.04 240 15.20 286 1043 4.60 / 85.95 5 164
Average= 4.30
(KJ/cycle)

Cycle 18 GMT 29/11/2023 8:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 32 15.20 429 209 0.21 / 76.90 5 6
2 7 2006.44 40 14.83 3150 1869 2.08 / 78.77 11 11
3 13 1443.00 20 14.92 2372 708 2.79 / 79.48 5 20
4 13 764.40 20 15.07 1413 426 3.21 / 79.91 5 23
5 13 177.24 20 15.22 580 177 3.39 / 80.08 5 21
6 13 72.24 20 15.24 419 128 3.52 / 80.21 5 18
7 13 45.24 20 15.24 374 114 3.63 / 80.33 5 19
8 8 0.04 240 15.20 283 1032 4.66 / 81.36 5 168
Average= 4.28
(KJ/cycle)

Cycle 17 GMT 19/11/2023 1:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.12 32 15.20 429 209 0.21 / 72.18 6 6
2 7 2009.08 40 14.84 3144 1866 2.07 / 74.05 6 11
3 13 1466.44 20 14.92 2387 712 2.79 / 74.76 5 19
4 13 892.24 20 15.04 1580 475 3.26 / 75.24 5 24
5 13 183.20 20 15.22 587 179 3.44 / 75.42 5 22
6 13 51.16 20 15.25 388 118 3.56 / 75.53 5 18
7 13 33.04 20 15.24 352 107 3.67 / 75.64 5 22
8 8 -0.08 240 15.20 289 1054 4.72 / 76.70 5 163
Average= 4.26
(KJ/cycle)

Cycle 16 GMT 8/11/2023 19:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 32 15.20 421 205 0.20 / 67.56 6 6
2 7 2010.96 40 14.85 3119 1853 2.06 / 69.42 6 12
3 13 1420.24 20 14.93 2365 706 2.76 / 70.12 5 19
4 13 747.64 20 15.09 1394 421 3.18 / 70.54 5 23
5 13 152.12 20 15.23 545 166 3.35 / 70.71 5 22
6 13 47.04 20 15.25 379 116 3.47 / 70.82 5 20
7 13 27.48 20 15.25 341 104 3.57 / 70.93 5 23
8 8 -0.08 238 15.21 289 1046 4.62 / 71.98 5 147
Average= 4.23
(KJ/cycle)

Cycle 15 GMT 29/10/2023 13:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.96 32 15.21 430 209 0.21 / 62.93 5 6
2 7 2004.48 40 14.85 3139 1865 2.07 / 64.79 6 12
3 13 1462.80 20 14.93 2369 707 2.78 / 65.50 5 19
4 13 793.88 20 15.08 1441 435 3.22 / 65.93 5 23
5 13 128.80 20 15.24 508 155 3.37 / 66.09 5 21
6 13 61.84 20 15.25 398 121 3.49 / 66.21 5 19
7 13 37.28 20 15.25 354 108 3.60 / 66.32 5 19
8 8 0.00 240 15.22 285 1041 4.64 / 67.36 5 170
Average= 4.21
(KJ/cycle)

Cycle 14 GMT 19/10/2023 6:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 32 15.22 415 202 0.20 / 58.28 5 6
2 7 2013.44 40 14.84 3177 1886 2.09 / 60.17 6 13
3 13 1363.80 20 14.95 2281 682 2.77 / 60.85 5 20
4 13 798.20 20 15.07 1462 441 3.21 / 61.29 5 24
5 13 110.96 20 15.25 480 146 3.36 / 61.44 5 19
6 13 65.60 20 15.25 411 125 3.48 / 61.56 5 21
7 13 37.68 20 15.25 356 109 3.59 / 61.67 5 22
8 8 -0.04 238 15.22 289 1047 4.64 / 62.72 5 136
Average= 4.18
(KJ/cycle)

Cycle 13 GMT 9/10/2023 0:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 32 15.21 414 202 0.20 / 53.67 6 6
2 7 2013.00 40 14.86 3108 1847 2.05 / 55.52 6 13
3 13 1450.08 20 14.94 2372 709 2.76 / 56.23 5 19
4 13 848.40 20 15.07 1515 457 3.21 / 56.69 5 24
5 13 144.52 20 15.24 530 162 3.38 / 56.85 5 21
6 13 67.00 20 15.26 405 124 3.50 / 56.97 5 20
7 8 0.08 259 15.23 281 1108 4.61 / 58.08 5 139
Average= 4.15
(KJ/cycle)

Cycle 12 GMT 28/ 9/2023 17:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 32 15.22 403 196 0.20 / 49.02 6 6
2 7 2008.40 40 14.86 3101 1843 2.04 / 50.87 6 12
3 13 1548.52 20 14.92 2503 747 2.79 / 51.61 5 20
4 13 750.32 20 15.10 1378 416 3.20 / 52.03 5 24
5 13 191.96 20 15.24 597 182 3.38 / 52.21 5 21
6 13 63.68 20 15.27 400 122 3.51 / 52.34 5 21
7 13 45.96 20 15.26 360 110 3.62 / 52.45 5 19
8 8 0.04 240 15.23 281 1027 4.64 / 53.47 5 144
Average= 4.11
(KJ/cycle)

Cycle 11 GMT 18/ 9/2023 11:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.68 32 15.23 408 199 0.20 / 44.41 6 6
2 7 2009.40 40 14.86 3123 1856 2.06 / 46.27 6 13
3 13 1355.84 20 14.98 2211 662 2.72 / 46.93 5 22
4 13 895.84 20 15.06 1575 474 3.19 / 47.41 5 24
5 13 172.12 20 15.24 572 174 3.37 / 47.58 5 22
6 13 75.48 20 15.26 414 126 3.49 / 47.71 5 20
7 13 49.96 20 15.27 368 112 3.61 / 47.82 5 20
8 8 0.08 240 15.24 276 1009 4.61 / 48.83 5 148
Average= 4.07
(KJ/cycle)

Cycle 10 GMT 8/ 9/2023 5: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 32 15.23 416 203 0.20 / 39.77 6 6
2 7 2015.00 40 14.86 3160 1878 2.08 / 41.65 6 13
3 13 1458.20 20 14.96 2361 706 2.79 / 42.36 5 22
4 13 768.96 20 15.10 1399 422 3.21 / 42.78 5 24
5 13 175.36 20 15.24 572 174 3.38 / 42.96 5 22
6 13 60.64 20 15.27 390 119 3.50 / 43.08 5 20
7 13 40.76 20 15.27 362 111 3.61 / 43.19 5 19
8 8 0.04 240 15.24 281 1028 4.64 / 44.21 5 145
Average= 4.02
(KJ/cycle)

Cycle 9 GMT 28/ 8/2023 22:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 32 15.23 418 204 0.20 / 35.05 6 6
2 7 2007.24 41 14.88 3109 1897 2.10 / 36.95 6 15
3 13 1427.56 20 14.96 2338 700 2.80 / 37.65 5 22
4 13 836.92 20 15.08 1504 454 3.25 / 38.10 5 26
5 13 232.84 20 15.23 664 202 3.46 / 38.31 5 25
6 13 70.64 20 15.27 412 126 3.58 / 38.43 5 23
7 13 41.92 20 15.27 355 108 3.69 / 38.54 5 23
8 8 -0.04 240 15.24 282 1031 4.72 / 39.57 5 158
Average= 3.96
(KJ/cycle)

Cycle 8 GMT 18/ 8/2023 16:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 32 15.24 404 197 0.20 / 30.41 6 6
2 7 2008.04 40 14.88 3127 1861 2.06 / 32.27 6 18
3 13 1454.32 20 14.96 2378 711 2.77 / 32.98 5 24
4 13 768.04 20 15.11 1409 426 3.20 / 33.41 5 28
5 13 200.72 20 15.25 607 185 3.38 / 33.59 5 27
6 13 68.52 20 15.28 404 123 3.50 / 33.72 5 24
7 13 46.56 20 15.28 361 110 3.61 / 33.83 5 24
8 8 0.12 242 15.25 277 1022 4.64 / 34.85 5 139
Average= 3.87
(KJ/cycle)

Cycle 7 GMT 8/ 8/2023 10:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 31 15.24 404 191 0.19 / 25.79 6 6
2 3 1019.96 1 15.27 1774 27 0.22 / 25.81 5 21
3 7 2004.08 40 14.88 3100 1845 2.06 / 27.66 21 21
4 13 1438.40 20 14.96 2351 703 2.77 / 28.36 5 29
5 13 746.40 20 15.12 1377 416 3.18 / 28.78 5 28
6 13 176.52 20 15.26 572 175 3.36 / 28.95 5 28
7 13 74.44 20 15.28 412 126 3.48 / 29.08 5 25
8 13 40.40 20 15.29 352 108 3.59 / 29.19 5 24
9 8 0.00 242 15.25 278 1026 4.62 / 30.21 5 147
Average= 3.78
(KJ/cycle)

Cycle 6 GMT 29/ 7/2023 3:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 31 15.23 444 210 0.21 / 21.18 6 6
2 3 1032.00 1 15.26 1776 27 0.24 / 21.20 5 23
3 7 2009.16 40 14.87 3160 1880 2.12 / 23.08 23 23
4 13 1358.56 20 14.98 2241 671 2.79 / 23.75 5 32
5 13 807.16 20 15.10 1464 442 3.23 / 24.20 5 35
6 13 133.24 20 15.27 518 158 3.39 / 24.35 5 30
7 13 57.68 20 15.29 385 118 3.51 / 24.47 5 31
8 13 35.08 20 15.29 339 104 3.61 / 24.58 5 32
9 8 0.16 240 15.25 279 1021 4.63 / 25.60 5 164
Average= 3.66
(KJ/cycle)

Cycle 5 GMT 18/ 7/2023 21: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 31 15.26 414 196 0.20 / 16.56 6 6
2 7 2005.72 40 14.90 3082 1837 2.03 / 18.40 6 24
3 13 1448.24 20 14.97 2351 704 2.74 / 19.10 5 31
4 13 771.56 20 15.12 1415 428 3.16 / 19.53 5 36
5 13 190.00 20 15.26 595 182 3.35 / 19.71 5 32
6 13 57.32 20 15.29 393 120 3.47 / 19.83 5 28
7 13 33.00 20 15.29 344 105 3.57 / 19.93 5 32
8 8 -0.04 240 15.25 282 1032 4.60 / 20.97 5 141
Average= 3.49
(KJ/cycle)

Cycle 4 GMT 8/ 7/2023 14:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 30 15.26 408 187 0.19 / 12.43 6 6
2 7 1523.60 40 15.06 2458 1481 1.67 / 13.91 6 24
3 13 1319.44 20 15.07 2161 651 2.32 / 14.56 5 29
4 13 721.04 20 15.17 1342 407 2.73 / 14.97 5 33
5 13 121.40 20 15.30 487 149 2.87 / 15.12 5 30
6 13 72.64 20 15.31 413 126 3.00 / 15.24 5 29
7 13 20.36 20 15.31 320 98 3.10 / 15.34 5 30
8 8 -0.04 238 15.28 281 1022 4.12 / 16.36 5 153
Average= 3.27
(KJ/cycle)

Cycle 3 GMT 7/ 7/2023 4:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 30 15.26 401 184 0.18 / 8.33 6 6
2 7 1524.44 41 15.07 2427 1500 1.68 / 9.83 6 24
3 13 1326.60 20 15.07 2159 651 2.33 / 10.48 5 29
4 13 725.32 20 15.17 1338 406 2.74 / 10.89 5 32
5 13 119.16 20 15.30 490 150 2.89 / 11.04 5 29
6 13 79.56 20 15.31 420 129 3.02 / 11.17 5 28
7 8 0.16 257 15.28 274 1076 4.09 / 12.24 5 164
Average= 3.06
(KJ/cycle)

Cycle 2 GMT 5/ 7/2023 19:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 31 15.29 409 194 0.19 / 4.35 6 6
2 7 1521.04 40 15.07 2454 1479 1.67 / 5.83 6 23
3 13 1216.04 20 15.09 2017 609 2.28 / 6.44 5 30
4 13 653.48 20 15.19 1248 379 2.66 / 6.81 5 33
5 13 101.64 20 15.30 460 141 2.80 / 6.96 5 30
6 13 71.92 20 15.31 404 124 2.93 / 7.08 5 30
7 8 0.12 257 15.28 272 1068 3.99 / 8.15 5 171
Average= 2.72
(KJ/cycle)

Cycle 1 GMT 4/ 7/2023 9:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 31 15.45 398 191 0.19 / 1.73 6 6
2 3 963.60 -1 15.59 0 0 0.00 / 1.73 6 6
3 7 989.56 40 15.21 1689 1028 1.22 / 2.75 6 29
4 13 130.12 20 15.37 496 152 1.37 / 2.91 5 30
5 13 85.52 20 15.37 426 131 1.50 / 3.04 5 29
6 13 46.92 20 15.36 363 112 1.61 / 3.15 5 27
7 8 0.04 240 15.33 273 1004 2.62 / 4.15 5 135
Average= 2.08
(KJ/cycle)

Cycle 0 GMT 3/ 7/2023 22:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 80.04 30 15.59 367 172 0.17 / 0.17 6 7
2 7 95.24 40 15.58 373 232 0.40 / 0.40 7 8
3 13 93.32 20 15.56 372 116 0.52 / 0.52 6 8
4 13 73.92 20 15.55 345 107 0.63 / 0.63 6 10
5 8 0.12 257 15.51 228 909 1.54 / 1.54 6 154
Average= 1.54
(KJ/cycle)