SIO Argo Site:
Pump Diagnostics Page   



Serial= 7806 WMO= 1902471

Return

←PreviousNext→

Cycle 36 GMT 30/ 4/2024 6:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 28 15.18 432 184 0.18 / 180.25 5 5
2 7 2011.76 40 14.80 3477 2058 2.24 / 182.31 5 20
3 13 1402.08 20 14.89 2561 763 3.00 / 183.07 4 25
4 13 663.72 20 15.07 1386 418 3.42 / 183.49 4 30
5 13 100.40 20 15.21 472 144 3.57 / 183.63 5 26
6 13 63.92 20 15.21 410 125 3.69 / 183.76 5 24
7 13 35.52 20 15.22 360 110 3.80 / 183.87 5 18
8 8 0.00 235 15.18 293 1045 4.85 / 184.91 5 137
Average= 10.88
(KJ/cycle)

Cycle 35 GMT 20/ 4/2024 0:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 28 15.18 431 183 0.18 / 175.54 5 6
2 7 2002.72 40 14.81 3449 2043 2.23 / 177.59 6 22
3 13 1264.92 20 14.93 2336 698 2.92 / 178.28 4 27
4 13 580.68 20 15.09 1247 376 3.30 / 178.66 5 30
5 13 109.68 20 15.21 488 148 3.45 / 178.81 5 25
6 13 61.08 20 15.22 404 123 3.57 / 178.93 5 24
7 13 15.88 20 15.23 325 99 3.67 / 179.03 5 24
8 8 -0.08 233 15.19 293 1037 4.71 / 180.07 5 137
Average= 11.25
(KJ/cycle)

Cycle 34 GMT 9/ 4/2024 18: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 29 15.19 436 192 0.19 / 170.70 5 6
2 7 2006.08 40 14.81 3463 2051 2.24 / 172.75 6 18
3 13 1400.80 20 14.90 2551 760 3.00 / 173.51 4 25
4 13 653.84 20 15.08 1361 410 3.41 / 173.92 5 30
5 13 150.68 20 15.21 556 169 3.58 / 174.09 5 26
6 13 60.08 20 15.23 400 122 3.71 / 174.21 5 24
7 13 16.88 20 15.23 326 99 3.80 / 174.31 5 23
8 8 0.00 235 15.19 294 1049 4.85 / 175.36 5 135
Average= 11.69
(KJ/cycle)

Cycle 33 GMT 30/ 3/2024 11:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.60 29 15.19 459 202 0.20 / 165.96 5 6
2 7 2002.56 40 14.81 3462 2051 2.25 / 168.01 6 17
3 13 1268.20 20 14.93 2345 700 2.95 / 168.71 4 25
4 13 581.92 20 15.11 1249 377 3.33 / 169.09 5 26
5 13 114.44 20 15.22 493 150 3.48 / 169.24 5 27
6 13 61.08 20 15.23 403 123 3.60 / 169.36 5 21
7 13 13.72 20 15.23 321 98 3.70 / 169.46 5 34
8 8 -0.04 235 15.19 293 1046 4.75 / 170.50 5 149
Average= 12.18
(KJ/cycle)

Cycle 32 GMT 20/ 3/2024 5:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.16 29 15.19 436 192 0.19 / 161.17 5 6
2 7 2003.16 41 14.81 3470 2107 2.30 / 163.28 6 23
3 13 1278.60 20 14.93 2361 705 3.00 / 163.98 4 28
4 13 570.56 20 15.11 1235 373 3.38 / 164.36 5 26
5 13 112.44 20 15.22 494 150 3.53 / 164.51 5 25
6 13 67.24 20 15.23 412 125 3.65 / 164.63 5 26
7 8 0.08 255 15.20 290 1124 4.78 / 165.76 5 147
Average= 12.75
(KJ/cycle)

Cycle 31 GMT 9/ 3/2024 23: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 28 15.20 436 186 0.19 / 156.41 5 6
2 7 2008.72 40 14.81 3473 2057 2.24 / 158.47 6 22
3 13 1291.40 20 14.93 2384 712 2.95 / 159.18 4 28
4 13 598.52 20 15.11 1276 386 3.34 / 159.56 4 30
5 13 109.84 20 15.22 487 148 3.49 / 159.71 5 28
6 13 71.48 20 15.23 423 129 3.62 / 159.84 5 25
7 8 0.04 255 15.20 294 1140 4.76 / 160.98 5 137
Average= 13.42
(KJ/cycle)

Cycle 30 GMT 28/ 2/2024 16:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.84 28 15.20 443 189 0.19 / 151.60 5 6
2 7 2009.72 40 14.82 3475 2060 2.25 / 153.66 6 19
3 13 1301.24 20 14.94 2395 716 2.96 / 154.38 4 27
4 13 701.56 20 15.08 1448 437 3.40 / 154.82 4 28
5 13 100.72 20 15.23 475 145 3.55 / 154.96 5 26
6 13 70.52 20 15.23 423 129 3.67 / 155.09 5 30
7 8 0.08 255 15.21 292 1133 4.81 / 156.22 5 153
Average= 14.20
(KJ/cycle)

Cycle 29 GMT 18/ 2/2024 10: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 28 15.20 442 188 0.19 / 146.82 5 6
2 7 2012.80 40 14.81 3482 2063 2.25 / 148.88 6 19
3 13 1390.20 20 14.92 2545 759 3.01 / 149.64 4 24
4 13 548.76 20 15.13 1206 365 3.38 / 150.00 5 28
5 13 93.32 20 15.24 465 142 3.52 / 150.15 5 21
6 13 65.36 20 15.24 417 127 3.64 / 150.27 5 29
7 8 0.00 253 15.21 297 1143 4.79 / 151.42 5 129
Average= 15.14
(KJ/cycle)

Cycle 28 GMT 8/ 2/2024 3:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.36 28 15.21 433 184 0.18 / 141.98 5 5
2 7 2007.52 40 14.82 3463 2053 2.24 / 144.03 5 19
3 13 1391.80 20 14.91 2541 758 2.99 / 144.79 4 29
4 13 658.32 20 15.10 1375 415 3.41 / 145.20 5 28
5 13 90.68 20 15.24 456 139 3.55 / 145.34 5 28
6 13 58.16 20 15.25 402 123 3.67 / 145.46 5 21
7 13 15.60 20 15.25 328 100 3.77 / 145.56 5 30
8 8 -0.08 236 15.21 297 1066 4.84 / 146.63 5 168
Average= 16.29
(KJ/cycle)

Cycle 27 GMT 28/ 1/2024 21:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 28 15.22 436 186 0.19 / 137.26 5 6
2 7 2005.48 40 14.83 3465 2055 2.24 / 139.32 6 19
3 13 1300.28 20 14.95 2397 717 2.96 / 140.04 4 28
4 13 586.16 20 15.12 1256 380 3.34 / 140.42 5 30
5 13 110.28 20 15.24 481 147 3.48 / 140.56 5 24
6 13 43.72 20 15.25 373 114 3.60 / 140.68 5 28
7 8 0.04 250 15.22 293 1115 4.71 / 141.79 5 136
Average= 17.72
(KJ/cycle)

Cycle 26 GMT 18/ 1/2024 14:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 28 15.22 432 184 0.18 / 132.55 5 5
2 7 2015.08 40 14.82 3484 2065 2.25 / 134.61 5 24
3 13 1304.60 20 14.95 2399 717 2.97 / 135.33 4 25
4 13 584.08 20 15.12 1252 379 3.35 / 135.71 5 29
5 13 112.92 20 15.24 492 150 3.50 / 135.86 5 26
6 13 46.44 20 15.25 375 114 3.61 / 135.97 5 25
7 8 0.04 253 15.22 287 1105 4.71 / 137.08 5 132
Average= 19.58
(KJ/cycle)

Cycle 25 GMT 8/ 1/2024 8: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.72 28 15.22 455 194 0.19 / 127.84 5 5
2 7 2008.48 40 14.83 3468 2057 2.25 / 129.90 5 19
3 13 1278.88 20 14.96 2364 707 2.96 / 130.61 4 26
4 13 585.16 20 15.13 1260 381 3.34 / 130.99 5 28
5 13 104.96 20 15.25 478 146 3.49 / 131.13 5 24
6 13 39.92 20 15.26 365 111 3.60 / 131.25 5 24
7 8 0.08 253 15.23 290 1117 4.71 / 132.36 5 140
Average= 22.06
(KJ/cycle)

Cycle 24 GMT 29/12/2023 1:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 28 15.22 442 188 0.19 / 123.07 5 5
2 7 2006.32 41 14.83 3482 2117 2.31 / 125.19 5 21
3 13 1277.88 20 14.96 2363 707 3.01 / 125.89 4 28
4 13 569.04 20 15.14 1232 373 3.39 / 126.27 5 29
5 13 103.00 20 15.25 473 144 3.53 / 126.41 5 25
6 13 40.68 20 15.26 371 113 3.64 / 126.53 5 24
7 13 12.48 20 15.27 322 98 3.74 / 126.62 5 25
8 8 0.04 233 15.23 289 1026 4.77 / 127.65 5 130
Average= 25.53
(KJ/cycle)

Cycle 23 GMT 18/12/2023 19: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 28 15.22 435 185 0.19 / 118.28 5 5
2 7 2008.56 41 14.83 3476 2114 2.30 / 120.39 5 21
3 13 1278.60 20 14.97 2365 708 3.01 / 121.10 4 27
4 13 572.44 20 15.14 1240 375 3.38 / 121.48 5 28
5 13 99.20 20 15.26 469 143 3.53 / 121.62 5 27
6 13 57.04 20 15.26 396 121 3.65 / 121.74 5 25
7 8 0.00 255 15.23 294 1142 4.79 / 122.88 5 142
Average= 30.72
(KJ/cycle)

Cycle 22 GMT 8/12/2023 12:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.12 28 15.23 440 188 0.19 / 113.53 5 5
2 7 2004.36 40 14.84 3460 2054 2.24 / 115.58 5 24
3 13 1378.60 20 14.95 2515 752 2.99 / 116.33 4 26
4 13 556.20 20 15.15 1211 367 3.36 / 116.70 5 27
5 13 96.72 20 15.26 465 142 3.50 / 116.84 5 26
6 13 55.84 20 15.26 399 122 3.62 / 116.97 5 30
7 8 0.04 253 15.23 293 1129 4.75 / 118.09 5 131
Average= 39.36
(KJ/cycle)

Cycle 21 GMT 28/11/2023 6:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 28 15.23 434 185 0.19 / 108.77 5 5
2 7 2003.12 40 14.85 3474 2064 2.25 / 110.83 5 22
3 13 1398.44 20 14.95 2542 760 3.01 / 111.59 4 27
4 13 550.40 20 15.16 1205 365 3.37 / 111.95 5 28
5 13 111.20 20 15.26 484 148 3.52 / 112.10 5 26
6 13 65.00 20 15.27 404 123 3.65 / 112.23 5 25
7 8 0.16 255 15.24 287 1115 4.76 / 113.34 5 135
Average= 56.67
(KJ/cycle)

Cycle 20 GMT 18/11/2023 0: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 28 15.23 443 189 0.19 / 104.02 5 5
2 7 2003.12 40 14.84 3472 2061 2.25 / 106.08 5 22
3 13 1391.04 20 14.95 2546 761 3.01 / 106.84 4 28
4 13 461.84 20 15.18 1065 323 3.33 / 107.17 5 27
5 13 118.48 20 15.26 502 153 3.49 / 107.32 5 25
6 13 69.84 20 15.27 417 127 3.62 / 107.45 5 24
7 8 0.04 255 15.24 292 1135 4.75 / 108.58 5 143
Average= 108.58
(KJ/cycle)

Cycle 18 GMT 28/10/2023 10:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 28 15.24 438 187 0.19 / 99.24 5 5
2 7 2006.60 41 14.85 3480 2119 2.31 / 101.36 5 19
3 13 1294.64 20 14.98 2398 718 3.02 / 102.08 4 28
4 13 473.32 20 15.18 1078 327 3.35 / 102.41 5 29
5 13 129.00 20 15.26 519 158 3.51 / 102.57 5 28
6 13 74.12 20 15.27 426 130 3.64 / 102.70 5 23
7 8 0.04 253 15.25 294 1134 4.77 / 103.83 5 131
Average= 5.46
(KJ/cycle)

Cycle 17 GMT 18/10/2023 4:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 28 15.24 437 186 0.19 / 94.55 5 6
2 7 2006.36 40 14.86 3482 2070 2.26 / 96.62 17 21
3 13 1213.88 20 15.00 2273 682 2.94 / 97.30 4 27
4 13 535.92 20 15.17 1183 359 3.30 / 97.66 5 28
5 13 116.32 20 15.27 500 153 3.45 / 97.81 5 23
6 13 70.68 20 15.28 418 128 3.58 / 97.94 5 25
7 8 0.16 255 15.25 288 1120 4.70 / 99.06 5 159
Average= 5.50
(KJ/cycle)

Cycle 16 GMT 7/10/2023 21:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 28 15.25 461 197 0.20 / 89.72 5 5
2 7 2007.68 40 14.86 3480 2069 2.27 / 91.79 5 20
3 13 1410.04 20 14.96 2573 770 3.04 / 92.56 4 28
4 13 579.80 20 15.16 1252 380 3.41 / 92.93 5 27
5 13 110.40 20 15.27 491 150 3.56 / 93.08 5 27
6 13 61.00 20 15.28 408 125 3.69 / 93.21 5 21
7 8 0.00 253 15.25 298 1150 4.84 / 94.36 5 132
Average= 5.55
(KJ/cycle)

Cycle 15 GMT 27/ 9/2023 15: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 28 15.25 432 184 0.18 / 84.93 5 5
2 7 2005.20 40 14.86 3481 2069 2.25 / 87.00 5 20
3 13 1304.16 20 14.99 2412 723 2.98 / 87.72 4 26
4 13 575.60 20 15.16 1248 378 3.36 / 88.10 5 28
5 13 106.28 20 15.28 483 148 3.50 / 88.25 5 26
6 13 60.40 20 15.29 407 124 3.63 / 88.37 5 24
7 8 0.08 255 15.25 295 1147 4.77 / 89.52 5 150
Average= 5.59
(KJ/cycle)

Cycle 14 GMT 17/ 9/2023 8:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.68 28 15.25 439 187 0.19 / 80.09 5 5
2 7 2003.68 40 14.87 3466 2062 2.25 / 82.15 5 20
3 13 1381.52 20 14.98 2524 756 3.01 / 82.91 4 26
4 13 646.44 20 15.15 1361 412 3.42 / 83.32 4 29
5 13 96.88 20 15.28 469 143 3.56 / 83.47 5 25
6 13 57.36 20 15.29 403 123 3.68 / 83.59 5 26
7 8 0.08 255 15.26 297 1156 4.84 / 84.75 5 137
Average= 5.65
(KJ/cycle)

Cycle 13 GMT 7/ 9/2023 2:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 28 15.25 434 185 0.19 / 75.31 5 5
2 7 2006.96 40 14.86 3477 2067 2.25 / 77.38 5 17
3 13 1221.28 20 15.01 2282 685 2.94 / 78.07 4 28
4 13 621.92 20 15.15 1323 401 3.34 / 78.47 4 28
5 13 123.72 20 15.27 518 158 3.50 / 78.62 5 25
6 13 39.12 20 15.29 372 114 3.61 / 78.74 5 28
7 8 0.08 255 15.26 300 1167 4.78 / 79.91 5 142
Average= 5.71
(KJ/cycle)

Cycle 12 GMT 27/ 8/2023 19:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 28 15.25 443 189 0.19 / 70.55 5 5
2 7 2009.04 40 14.87 3473 2066 2.25 / 72.61 5 21
3 13 1302.56 20 14.99 2404 721 2.98 / 73.33 4 28
4 13 573.72 20 15.17 1244 377 3.35 / 73.71 5 28
5 13 103.16 20 15.29 480 147 3.50 / 73.86 5 26
6 13 32.12 20 15.30 363 111 3.61 / 73.97 5 23
7 8 0.00 255 15.26 298 1160 4.77 / 75.13 5 153
Average= 5.78
(KJ/cycle)

Cycle 11 GMT 17/ 8/2023 13:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 28 15.26 438 187 0.19 / 65.74 5 5
2 7 2005.76 40 14.87 3471 2065 2.25 / 67.80 5 20
3 13 1297.32 20 15.00 2400 720 2.97 / 68.52 4 29
4 13 598.08 20 15.16 1286 390 3.36 / 68.91 4 28
5 13 109.16 20 15.28 490 150 3.51 / 69.06 5 26
6 13 62.76 20 15.29 414 127 3.64 / 69.19 5 25
7 8 0.04 255 15.26 300 1167 4.81 / 70.36 5 144
Average= 5.86
(KJ/cycle)

Cycle 10 GMT 7/ 8/2023 6:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 27 15.26 441 182 0.18 / 61.01 5 5
2 7 2005.32 40 14.88 3467 2064 2.25 / 63.07 15 20
3 13 1201.56 20 15.02 2250 676 2.92 / 63.75 4 29
4 13 528.72 20 15.19 1173 356 3.28 / 64.10 5 27
5 13 162.76 20 15.27 579 177 3.45 / 64.28 5 27
6 13 65.04 20 15.29 411 126 3.58 / 64.40 5 23
7 8 0.16 255 15.26 295 1148 4.73 / 65.55 5 146
Average= 5.96
(KJ/cycle)

Cycle 9 GMT 28/ 7/2023 0: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 25 15.26 440 168 0.17 / 56.14 5 5
2 10 1036.68 3 15.23 1953 89 0.26 / 56.23 5 9
3 7 2009.96 40 14.88 3481 2072 2.33 / 58.31 15 19
4 13 1189.64 20 15.03 2232 671 3.00 / 58.98 4 30
5 13 608.20 20 15.17 1300 394 3.39 / 59.37 5 30
6 13 122.60 20 15.29 513 157 3.55 / 59.53 5 30
7 13 69.48 20 15.29 424 130 3.68 / 59.66 5 27
8 8 0.04 255 15.26 300 1167 4.85 / 60.82 5 150
Average= 6.08
(KJ/cycle)

Cycle 8 GMT 17/ 7/2023 17:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 39 15.26 439 261 0.26 / 51.44 5 7
2 3 614.40 -6 15.56 0 0 0.00 / 51.44 5 7
3 7 2002.72 40 14.89 3463 2063 2.32 / 53.50 7 19
4 13 1375.28 20 14.99 2521 756 3.08 / 54.25 4 29
5 13 440.28 20 15.22 1029 313 3.39 / 54.57 5 28
6 13 113.44 20 15.30 490 150 3.54 / 54.72 5 26
7 13 60.44 20 15.30 400 122 3.67 / 54.84 5 28
8 8 0.00 253 15.27 294 1136 4.80 / 55.98 5 132
Average= 6.22
(KJ/cycle)

Cycle 7 GMT 7/ 7/2023 10: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 59 15.24 432 388 0.39 / 38.22 5 9
2 3 316.96 -11 15.58 0 0 0.00 / 38.22 5 9
3 5 1831.16 20 14.94 3247 970 1.36 / 39.19 4 16
4 5 1799.64 20 14.90 3182 948 2.31 / 40.14 4 19
5 5 1418.44 10 15.06 2594 391 2.70 / 40.53 4 25
6 5 1300.84 7 15.14 2412 256 2.95 / 40.78 4 22
7 5 1301.96 7 15.15 2424 257 3.21 / 41.04 4 21
8 5 1336.76 8 15.15 2451 297 3.51 / 41.34 4 21
9 5 1366.04 9 15.15 2488 339 3.85 / 41.68 4 22
10 5 1306.72 8 15.19 2392 291 4.14 / 41.97 4 19
11 5 1381.00 9 15.17 2555 349 4.49 / 42.32 4 21
12 5 1326.08 8 15.18 2447 297 4.78 / 42.61 4 21
13 5 1434.64 11 15.13 2637 439 5.22 / 43.05 4 20
14 5 1469.56 12 15.10 2667 483 5.71 / 43.54 4 19
15 5 1411.88 10 15.13 2572 389 6.09 / 43.92 4 21
16 5 1424.84 10 15.14 2580 391 6.49 / 44.32 4 21
17 5 1378.80 9 15.15 2525 344 6.83 / 44.66 4 18
18 5 1394.48 10 15.15 2551 386 7.22 / 45.05 4 21
19 5 1333.40 8 15.17 2454 298 7.51 / 45.34 4 19
20 5 1315.72 8 15.19 2399 292 7.81 / 45.64 4 20
21 5 1339.24 8 15.18 2492 303 8.11 / 45.94 4 20
22 5 1323.32 8 15.19 2451 298 8.41 / 46.24 4 17
23 5 1381.24 9 15.16 2551 348 8.75 / 46.58 4 21
24 7 2004.32 40 14.89 3471 2067 10.82 / 48.65 21 21
25 13 1380.36 20 15.00 2525 757 11.58 / 49.41 4 27
26 13 557.88 20 15.19 1213 369 11.95 / 49.78 5 29
27 13 111.48 20 15.30 489 150 12.10 / 49.93 5 28
28 13 47.36 20 15.31 380 116 12.21 / 50.04 5 20
29 8 0.00 253 15.27 293 1132 13.35 / 51.18 5 129
Average= 6.40
(KJ/cycle)

Cycle 6 GMT 27/ 6/2023 3:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.44 49 15.25 455 340 0.34 / 30.19 5 6
2 5 1478.48 12 15.10 2651 480 0.82 / 30.67 4 16
3 5 1690.72 17 14.96 2989 760 1.58 / 31.43 4 18
4 5 1558.96 14 15.01 2793 587 2.17 / 32.02 4 21
5 5 1324.24 8 15.12 2443 296 2.46 / 32.32 4 22
6 5 1309.96 8 15.15 2431 295 2.76 / 32.61 4 22
7 5 1485.80 12 15.08 2712 491 3.25 / 33.10 4 20
8 7 2009.48 40 14.89 3473 2069 5.32 / 35.17 20 21
9 13 1406.12 20 14.99 2557 767 6.08 / 35.94 4 29
10 13 696.88 20 15.15 1438 436 6.52 / 36.37 5 30
11 13 141.16 20 15.29 536 164 6.68 / 36.54 5 27
12 13 52.00 20 15.31 385 118 6.80 / 36.65 5 29
13 13 30.08 20 15.30 349 107 6.91 / 36.76 5 26
14 8 0.00 240 15.27 292 1070 7.98 / 37.83 5 134
Average= 5.40
(KJ/cycle)

Cycle 5 GMT 16/ 6/2023 21:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.68 31 15.25 466 220 0.22 / 21.93 5 5
2 10 1006.84 4 15.22 1909 116 0.34 / 22.04 5 10
3 10 1039.20 3 15.22 1973 90 0.43 / 22.13 5 12
4 10 1245.32 3 15.20 2299 105 0.53 / 22.24 5 16
5 3 1226.40 6 15.17 2277 207 0.74 / 22.45 5 17
6 5 1516.32 13 15.05 2736 535 1.27 / 22.98 4 20
7 5 1438.12 11 15.08 2634 437 1.71 / 23.42 4 21
8 5 1377.04 9 15.12 2536 345 2.06 / 23.76 4 20
9 5 1341.92 8 15.16 2475 300 2.36 / 24.06 4 21
10 5 1325.40 8 15.17 2442 296 2.65 / 24.36 4 20
11 5 1383.52 9 15.15 2520 344 3.00 / 24.70 4 19
12 5 1395.24 10 15.14 2545 385 3.38 / 25.09 4 21
13 7 2006.96 40 14.89 3472 2068 5.45 / 27.16 21 22
14 13 1424.36 20 14.99 2596 778 6.23 / 27.94 4 28
15 13 741.76 20 15.14 1510 457 6.68 / 28.39 4 30
16 13 175.08 20 15.28 591 181 6.87 / 28.57 5 28
17 13 45.68 20 15.30 377 115 6.98 / 28.69 5 27
18 8 -0.04 261 15.27 292 1164 8.14 / 29.85 5 154
Average= 4.98
(KJ/cycle)

Cycle 4 GMT 6/ 6/2023 15:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 38 15.24 431 250 0.25 / 15.45 5 5
2 10 1006.32 4 15.25 1900 116 0.37 / 15.56 5 12
3 10 1081.28 3 15.24 2039 93 0.46 / 15.66 5 15
4 3 1029.20 1 15.28 1955 30 0.49 / 15.69 5 14
5 5 1373.60 9 15.15 2506 342 0.83 / 16.03 4 18
6 5 1425.40 10 15.13 2599 393 1.22 / 16.42 4 20
7 5 1358.96 9 15.16 2487 339 1.56 / 16.76 4 21
8 5 1346.68 9 15.15 2481 338 1.90 / 17.10 4 21
9 5 1470.16 12 15.11 2671 484 2.39 / 17.58 4 20
10 7 1507.44 40 15.02 2712 1629 4.01 / 19.21 20 23
11 13 1308.28 20 15.03 2409 724 4.74 / 19.94 4 24
12 13 569.40 20 15.19 1236 375 5.11 / 20.31 5 27
13 13 99.80 20 15.29 461 141 5.26 / 20.45 5 25
14 13 28.68 20 15.30 349 107 5.36 / 20.56 5 25
15 8 -0.16 255 15.26 295 1148 6.51 / 21.71 5 148
Average= 4.34
(KJ/cycle)

Cycle 3 GMT 5/ 6/2023 6:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.68 28 15.26 454 194 0.19 / 8.67 5 5
2 10 1035.88 4 15.23 1952 119 0.31 / 8.79 5 12
3 10 1075.88 3 15.23 2023 92 0.41 / 8.88 5 14
4 3 1143.24 4 15.22 2133 130 0.54 / 9.01 5 18
5 5 1373.16 9 15.14 2500 341 0.88 / 9.35 4 20
6 5 1300.36 7 15.18 2415 257 1.13 / 9.61 4 21
7 5 1338.04 8 15.17 2461 299 1.43 / 9.91 4 20
8 5 1397.68 10 15.13 2523 382 1.81 / 10.29 4 20
9 5 1385.80 9 15.13 2519 343 2.16 / 10.63 4 20
10 5 1382.40 9 15.13 2505 341 2.50 / 10.97 4 20
11 7 1508.76 40 15.03 2708 1628 4.13 / 12.60 20 22
12 13 1185.52 20 15.06 2219 668 4.79 / 13.27 4 26
13 13 728.08 20 15.14 1491 451 5.24 / 13.72 4 27
14 13 146.40 20 15.28 553 169 5.41 / 13.89 5 26
15 13 44.12 20 15.30 378 116 5.53 / 14.01 5 25
16 13 11.56 20 15.30 322 99 5.63 / 14.10 5 25
17 8 0.04 242 15.26 296 1093 6.72 / 15.20 5 156
Average= 3.80
(KJ/cycle)

Cycle 2 GMT 3/ 6/2023 21:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.68 31 15.29 459 218 0.22 / 4.55 5 5
2 3 856.80 -2 15.57 0 0 0.00 / 4.55 5 5
3 7 1523.12 40 15.09 2713 1638 1.86 / 6.19 5 19
4 13 1204.88 20 15.11 2232 675 2.53 / 6.86 4 24
5 13 372.92 20 15.26 912 278 2.81 / 7.14 5 26
6 13 78.56 20 15.32 429 131 2.94 / 7.27 5 26
7 13 27.08 20 15.32 343 105 3.04 / 7.38 5 27
8 8 0.00 250 15.28 288 1100 4.14 / 8.48 5 136
Average= 2.83
(KJ/cycle)

Cycle 1 GMT 2/ 6/2023 11:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 31 15.46 441 211 0.21 / 1.92 5 6
2 3 798.12 -3 15.58 0 0 0.00 / 1.92 5 6
3 7 877.08 40 15.26 1702 1039 1.25 / 2.96 6 22
4 13 104.44 20 15.38 474 146 1.40 / 3.10 5 21
5 13 31.88 20 15.38 350 108 1.50 / 3.21 5 31
6 8 -0.08 255 15.34 287 1123 2.63 / 4.33 5 148
Average= 2.17
(KJ/cycle)

Cycle 0 GMT 2/ 6/2023 1:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 129.40 30 15.61 467 219 0.22 / 0.22 5 7
2 7 143.08 40 15.59 481 300 0.52 / 0.52 7 7
3 13 80.40 20 15.58 378 118 0.64 / 0.64 5 8
4 13 23.32 20 15.57 291 91 0.73 / 0.73 5 9
5 8 0.04 250 15.53 252 978 1.71 / 1.71 5 -99
Average= 1.71
(KJ/cycle)