SIO Argo Site:
Pump Diagnostics Page   



Serial= 7761 WMO= 1902430

Return

←PreviousNext→

Cycle 87 GMT 12/ 5/2024 12:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.12 37 14.93 456 252 0.25 / 541.50 6 6
2 7 2011.68 40 14.54 3135 1823 2.08 / 543.32 6 24
3 13 1916.40 20 14.51 3019 876 2.95 / 544.20 5 25
4 13 1381.80 20 14.57 2316 675 3.63 / 544.87 5 34
5 13 940.84 20 14.66 1720 504 4.13 / 545.38 5 39
6 13 81.32 20 14.99 497 149 4.28 / 545.53 5 29
7 13 19.76 20 15.01 396 119 4.40 / 545.65 5 15
8 8 0.00 400 14.92 345 2059 6.46 / 547.71 5 46
Average= 7.94
(KJ/cycle)

Cycle 86 GMT 2/ 5/2024 15:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.52 37 14.93 479 265 0.26 / 535.01 6 6
2 7 2004.52 41 14.54 3141 1872 2.14 / 536.88 6 24
3 13 1917.44 20 14.51 3036 881 3.02 / 537.77 5 29
4 13 1487.88 20 14.53 2450 712 3.73 / 538.48 5 31
5 13 931.64 20 14.66 1704 500 4.23 / 538.98 5 39
6 13 75.16 20 15.00 475 142 4.37 / 539.12 5 27
7 13 19.32 20 15.02 383 115 4.49 / 539.24 5 15
8 8 0.20 400 14.93 337 2013 6.50 / 541.25 5 39
Average= 7.96
(KJ/cycle)

Cycle 85 GMT 22/ 4/2024 18:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 37 14.93 481 266 0.27 / 528.53 6 6
2 7 2004.64 40 14.55 3128 1820 2.09 / 530.35 6 22
3 13 1917.32 20 14.52 3016 876 2.96 / 531.22 5 28
4 13 1498.48 20 14.54 2458 715 3.68 / 531.94 5 34
5 13 943.64 20 14.66 1716 503 4.18 / 532.44 5 37
6 13 166.92 20 14.96 611 183 4.36 / 532.62 5 34
7 13 17.20 20 15.01 379 114 4.48 / 532.74 5 11
8 8 -0.16 400 14.92 337 2011 6.49 / 534.75 5 42
Average= 7.98
(KJ/cycle)

Cycle 84 GMT 12/ 4/2024 21: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 37 14.94 473 261 0.26 / 521.98 6 7
2 7 2011.44 40 14.55 3130 1822 2.08 / 523.80 7 25
3 13 1919.32 20 14.51 3040 882 2.97 / 524.68 5 28
4 13 1505.44 20 14.53 2490 724 3.69 / 525.41 5 32
5 13 951.48 20 14.66 1738 510 4.20 / 525.92 5 38
6 13 175.76 20 14.96 636 190 4.39 / 526.11 5 34
7 13 22.76 20 15.01 393 118 4.51 / 526.23 5 14
8 8 -0.12 400 14.92 341 2035 6.54 / 528.26 5 38
Average= 8.00
(KJ/cycle)

Cycle 83 GMT 2/ 4/2024 23:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 36 14.95 460 248 0.25 / 515.53 6 6
2 7 2004.04 40 14.54 3140 1826 2.07 / 517.35 6 24
3 13 1911.84 20 14.51 3019 876 2.95 / 518.23 5 27
4 13 1377.56 20 14.56 2325 677 3.63 / 518.91 5 35
5 13 941.48 20 14.66 1719 504 4.13 / 519.41 5 39
6 13 84.00 20 14.99 493 148 4.28 / 519.56 5 30
7 13 21.72 20 15.01 393 118 4.40 / 519.68 5 14
8 8 -0.16 400 14.92 342 2041 6.44 / 521.72 5 38
Average= 8.03
(KJ/cycle)

Cycle 82 GMT 24/ 3/2024 2:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 36 14.93 478 257 0.26 / 509.17 6 6
2 7 2004.40 40 14.55 3127 1820 2.08 / 510.99 6 22
3 13 1916.36 20 14.51 3026 878 2.95 / 511.87 5 28
4 13 1376.92 20 14.58 2306 672 3.63 / 512.54 5 33
5 13 847.76 20 14.70 1587 467 4.09 / 513.01 5 38
6 13 92.88 20 15.00 502 151 4.24 / 513.16 5 32
7 13 22.20 20 15.01 383 115 4.36 / 513.27 5 15
8 8 -0.20 400 14.93 336 2007 6.37 / 515.28 5 44
Average= 8.05
(KJ/cycle)

Cycle 81 GMT 14/ 3/2024 5:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 36 14.94 462 248 0.25 / 502.75 6 6
2 7 2013.40 40 14.55 3141 1828 2.08 / 504.58 6 25
3 13 1921.80 20 14.52 3045 884 2.96 / 505.46 5 26
4 13 1395.32 20 14.56 2327 678 3.64 / 506.14 5 32
5 13 950.88 20 14.66 1718 504 4.14 / 506.64 5 40
6 13 87.64 20 15.00 493 148 4.29 / 506.79 5 30
7 13 21.76 20 15.01 385 116 4.41 / 506.91 5 14
8 8 -0.24 400 14.93 336 2007 6.41 / 508.91 5 38
Average= 8.08
(KJ/cycle)

Cycle 80 GMT 4/ 3/2024 8: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 36 14.93 469 252 0.25 / 496.21 6 6
2 7 2004.60 40 14.55 3127 1820 2.07 / 498.03 6 23
3 13 1918.12 20 14.52 3024 878 2.95 / 498.90 5 28
4 13 1400.08 20 14.57 2342 682 3.63 / 499.59 5 33
5 13 971.12 20 14.65 1756 515 4.15 / 500.10 5 38
6 13 290.00 20 14.91 801 239 4.39 / 500.34 5 40
7 13 19.00 20 15.01 386 116 4.50 / 500.46 5 13
8 8 -0.16 400 14.92 343 2047 6.55 / 502.50 5 40
Average= 8.10
(KJ/cycle)

Cycle 79 GMT 23/ 2/2024 10:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 36 14.94 481 259 0.26 / 489.76 6 6
2 7 2004.88 40 14.55 3133 1823 2.08 / 491.59 6 24
3 13 1916.88 20 14.52 3033 881 2.96 / 492.47 5 29
4 13 1382.20 20 14.57 2337 681 3.64 / 493.15 5 32
5 13 755.16 20 14.73 1471 433 4.08 / 493.58 5 40
6 13 212.40 20 14.94 695 208 4.28 / 493.79 5 36
7 13 20.48 20 15.01 390 117 4.40 / 493.91 5 14
8 8 -0.32 400 14.92 343 2047 6.45 / 495.95 5 41
Average= 8.13
(KJ/cycle)

Cycle 78 GMT 13/ 2/2024 13:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 36 14.92 476 256 0.26 / 483.33 6 7
2 7 2006.20 40 14.55 3124 1818 2.07 / 485.14 7 23
3 13 1919.08 20 14.52 3029 880 2.95 / 486.02 5 26
4 13 1490.44 20 14.54 2466 717 3.67 / 486.74 5 31
5 13 834.00 20 14.70 1582 465 4.14 / 487.21 5 40
6 13 85.72 20 15.00 500 150 4.29 / 487.36 5 29
7 13 23.60 20 15.02 395 119 4.40 / 487.47 5 16
8 8 -0.24 400 14.93 340 2030 6.43 / 489.50 5 42
Average= 8.16
(KJ/cycle)

Cycle 77 GMT 3/ 2/2024 16:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 36 14.93 486 261 0.26 / 476.89 6 6
2 7 2006.04 41 14.54 3145 1875 2.14 / 478.76 6 26
3 13 1922.68 20 14.52 3041 883 3.02 / 479.65 5 27
4 13 1298.12 20 14.59 2209 645 3.66 / 480.29 5 35
5 13 776.00 20 14.72 1495 440 4.10 / 480.73 5 40
6 13 116.36 20 14.98 551 165 4.27 / 480.90 5 32
7 13 25.48 20 15.01 401 120 4.39 / 481.02 5 17
8 8 -0.32 400 14.92 344 2053 6.44 / 483.07 5 43
Average= 8.19
(KJ/cycle)

Cycle 76 GMT 24/ 1/2024 19: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 36 14.92 468 251 0.25 / 470.46 6 7
2 7 2006.00 41 14.55 3136 1871 2.12 / 472.33 7 24
3 13 1917.68 20 14.53 3026 879 3.00 / 473.21 5 26
4 13 1288.80 20 14.60 2202 643 3.64 / 473.85 5 35
5 13 855.16 20 14.69 1608 472 4.12 / 474.33 5 38
6 13 89.28 20 14.99 506 152 4.27 / 474.48 5 30
7 13 11.60 20 15.02 376 113 4.38 / 474.59 5 13
8 8 -0.12 400 14.93 341 2036 6.42 / 476.63 6 42
Average= 8.22
(KJ/cycle)

Cycle 75 GMT 14/ 1/2024 21:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 36 14.94 477 257 0.26 / 464.01 6 7
2 7 2004.00 40 14.57 3117 1817 2.07 / 465.82 7 24
3 13 1915.16 20 14.53 3023 878 2.95 / 466.70 5 26
4 13 1377.04 20 14.58 2308 673 3.62 / 467.37 5 32
5 13 941.88 20 14.66 1716 503 4.13 / 467.88 5 39
6 13 159.56 20 14.96 606 181 4.31 / 468.06 5 34
7 13 33.64 20 15.01 405 122 4.43 / 468.18 5 20
8 8 -0.08 400 14.92 340 2029 6.46 / 470.21 5 40
Average= 8.25
(KJ/cycle)

Cycle 74 GMT 5/ 1/2024 0:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 36 14.93 484 260 0.26 / 457.52 6 7
2 7 2005.36 40 14.56 3135 1826 2.09 / 459.34 7 25
3 13 1919.24 20 14.53 3027 880 2.97 / 460.22 5 27
4 13 1491.00 20 14.55 2458 715 3.68 / 460.94 5 34
5 13 933.40 20 14.67 1698 498 4.18 / 461.44 5 38
6 13 162.08 20 14.97 610 183 4.36 / 461.62 5 34
7 13 20.64 20 15.02 386 116 4.48 / 461.74 5 14
8 8 -0.08 400 14.93 337 2013 6.49 / 463.75 5 44
Average= 8.28
(KJ/cycle)

Cycle 73 GMT 26/12/2023 3:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 36 14.94 476 256 0.26 / 451.00 6 6
2 7 2012.84 40 14.55 3152 1834 2.09 / 452.84 6 24
3 13 1924.60 20 14.52 3037 882 2.97 / 453.72 5 25
4 13 1514.60 20 14.54 2505 728 3.70 / 454.45 5 33
5 13 859.28 20 14.69 1617 475 4.18 / 454.92 5 38
6 13 100.32 20 15.00 527 158 4.33 / 455.08 5 31
7 13 24.80 20 15.02 397 119 4.45 / 455.20 5 16
8 8 -0.20 400 14.93 345 2060 6.51 / 457.26 5 35
Average= 8.31
(KJ/cycle)

Cycle 72 GMT 16/12/2023 6:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 36 14.93 483 260 0.26 / 444.54 6 7
2 7 2005.72 40 14.57 3128 1823 2.08 / 446.37 7 22
3 13 1922.76 20 14.53 3040 883 2.97 / 447.25 5 27
4 13 1397.68 20 14.58 2328 679 3.64 / 447.93 5 33
5 13 964.80 20 14.66 1741 510 4.16 / 448.44 5 36
6 13 95.24 20 15.00 509 153 4.31 / 448.59 5 30
7 13 19.60 20 15.02 386 116 4.42 / 448.71 5 13
8 8 -0.28 400 14.93 341 2036 6.46 / 450.75 5 33
Average= 8.35
(KJ/cycle)

Cycle 71 GMT 6/12/2023 9: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 36 14.94 471 253 0.25 / 438.09 6 7
2 7 2006.64 40 14.56 3134 1825 2.08 / 439.92 7 23
3 13 1924.68 20 14.53 3052 887 2.97 / 440.80 5 26
4 13 1397.00 20 14.57 2340 682 3.65 / 441.49 5 34
5 13 756.52 20 14.73 1477 435 4.08 / 441.92 5 39
6 13 107.48 20 14.99 538 161 4.24 / 442.08 5 31
7 13 9.00 20 15.02 381 114 4.36 / 442.20 5 13
8 8 -0.16 400 14.92 350 2089 6.45 / 444.28 5 34
Average= 8.38
(KJ/cycle)

Cycle 70 GMT 26/11/2023 11:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 36 14.94 479 258 0.26 / 431.70 6 8
2 3 1019.88 1 15.00 1835 28 0.29 / 431.73 5 7
3 7 2005.64 40 14.57 3136 1828 2.11 / 433.56 7 25
4 13 1919.92 20 14.54 3025 880 2.99 / 434.44 5 28
5 13 1299.08 20 14.61 2201 643 3.64 / 435.08 5 33
6 13 975.48 20 14.66 1764 517 4.15 / 435.60 5 36
7 13 190.84 20 14.96 648 194 4.35 / 435.79 5 35
8 8 -0.16 400 14.94 342 2044 6.39 / 437.84 5 34
Average= 8.42
(KJ/cycle)

Cycle 69 GMT 16/11/2023 14:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 36 14.93 487 262 0.26 / 425.30 6 8
2 7 2012.88 40 14.56 3140 1829 2.09 / 427.13 8 24
3 13 1925.52 20 14.53 3046 885 2.98 / 428.01 5 27
4 13 1497.04 20 14.55 2481 722 3.70 / 428.73 5 32
5 13 735.24 20 14.75 1430 422 4.12 / 429.16 5 40
6 13 50.08 20 15.03 430 129 4.25 / 429.28 5 23
7 13 11.16 20 15.03 377 113 4.36 / 429.40 5 12
8 8 -0.12 400 14.94 343 2050 6.41 / 431.45 5 36
Average= 8.46
(KJ/cycle)

Cycle 68 GMT 6/11/2023 16:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 36 14.91 487 261 0.26 / 419.01 6 9
2 7 2003.68 40 14.57 3132 1825 2.09 / 420.84 9 23
3 13 1913.96 20 14.54 3021 879 2.97 / 421.71 5 27
4 13 1381.88 20 14.59 2315 676 3.64 / 422.39 5 34
5 13 839.36 20 14.72 1566 461 4.10 / 422.85 5 38
6 13 85.12 20 15.01 490 147 4.25 / 423.00 5 29
7 8 -0.20 400 14.94 341 2038 6.29 / 425.04 5 30
Average= 8.50
(KJ/cycle)

Cycle 67 GMT 27/10/2023 19:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 36 14.92 482 259 0.26 / 412.37 6 9
2 7 2014.24 40 14.56 3141 1829 2.09 / 414.20 9 23
3 13 1925.96 20 14.53 3044 885 2.97 / 415.09 5 28
4 13 1388.84 20 14.58 2335 681 3.65 / 415.77 5 33
5 13 961.92 20 14.67 1746 512 4.17 / 416.28 5 38
6 13 389.40 20 14.87 947 282 4.45 / 416.56 5 39
7 13 13.88 20 15.02 384 115 4.56 / 416.68 5 12
8 8 -0.16 400 14.92 347 2071 6.63 / 418.75 5 29
Average= 8.55
(KJ/cycle)

Cycle 66 GMT 17/10/2023 22:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 36 14.93 502 270 0.27 / 405.81 6 8
2 7 2014.32 40 14.56 3169 1846 2.12 / 407.66 5 25
3 13 1923.56 20 14.54 3031 881 3.00 / 408.54 5 27
4 13 1399.36 20 14.58 2338 682 3.68 / 409.22 5 33
5 13 986.44 20 14.66 1770 519 4.20 / 409.74 5 37
6 13 199.40 20 14.96 656 196 4.39 / 409.93 5 36
7 13 13.88 20 15.02 381 114 4.51 / 410.05 5 11
8 8 -0.16 400 14.93 346 2066 6.57 / 412.11 5 35
Average= 8.59
(KJ/cycle)

Cycle 65 GMT 8/10/2023 1:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 36 14.93 497 267 0.27 / 399.47 6 8
2 7 2009.68 40 14.57 3147 1834 2.10 / 401.30 8 24
3 13 1913.24 20 14.56 3022 880 2.98 / 402.18 5 28
4 13 1396.36 20 14.59 2335 681 3.66 / 402.87 5 33
5 13 860.72 20 14.71 1613 475 4.14 / 403.34 5 39
6 13 28.60 20 15.04 398 120 4.26 / 403.46 5 14
7 8 -0.08 400 14.95 348 2081 6.34 / 405.54 5 31
Average= 8.63
(KJ/cycle)

Cycle 64 GMT 28/ 9/2023 3:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 35 14.93 507 265 0.26 / 393.11 6 9
2 7 2005.92 40 14.58 3130 1825 2.09 / 394.93 9 24
3 13 1921.16 20 14.55 3040 885 2.97 / 395.82 5 29
4 13 1409.92 20 14.58 2352 686 3.66 / 396.50 5 34
5 13 982.68 20 14.67 1759 516 4.18 / 397.02 5 38
6 13 95.40 20 15.01 504 151 4.33 / 397.17 5 30
7 8 -0.08 400 14.95 340 2033 6.36 / 399.20 5 29
Average= 8.68
(KJ/cycle)

Cycle 63 GMT 18/ 9/2023 6:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 35 14.94 491 257 0.26 / 386.59 6 9
2 7 2003.68 40 14.58 3131 1826 2.08 / 388.42 9 24
3 13 1913.08 20 14.55 3037 884 2.97 / 389.30 5 26
4 13 1481.20 20 14.57 2468 719 3.69 / 390.02 5 31
5 13 833.96 20 14.73 1579 465 4.15 / 390.49 5 38
6 13 94.92 20 15.01 519 156 4.31 / 390.64 5 32
7 13 20.40 20 15.03 396 119 4.43 / 390.76 5 16
8 8 -0.16 400 14.94 348 2080 6.51 / 392.84 5 31
Average= 8.73
(KJ/cycle)

Cycle 62 GMT 8/ 9/2023 9:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 35 14.94 501 262 0.26 / 380.23 6 9
2 7 2013.64 40 14.58 3135 1828 2.09 / 382.06 9 25
3 13 1824.76 20 14.57 2914 849 2.94 / 382.90 5 29
4 13 1617.68 20 14.54 2625 763 3.70 / 383.67 5 31
5 13 823.88 20 14.74 1552 458 4.16 / 384.13 5 40
6 13 150.16 20 15.00 585 175 4.34 / 384.30 5 34
7 8 -0.04 400 14.96 340 2035 6.37 / 386.34 5 26
Average= 8.78
(KJ/cycle)

Cycle 61 GMT 29/ 8/2023 12:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 35 14.92 510 266 0.27 / 373.72 6 10
2 7 2013.48 40 14.59 3158 1843 2.11 / 375.57 10 23
3 13 1918.60 20 14.55 3049 887 3.00 / 376.45 5 28
4 13 1605.48 20 14.54 2640 768 3.76 / 377.22 5 32
5 13 938.12 20 14.70 1724 507 4.27 / 377.73 5 39
6 13 81.08 20 15.03 491 148 4.42 / 377.88 5 29
7 8 -0.04 400 14.96 349 2088 6.51 / 379.97 5 30
Average= 8.84
(KJ/cycle)

Cycle 60 GMT 19/ 8/2023 15:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 36 14.94 478 257 0.26 / 367.07 6 8
2 7 2005.88 40 14.59 3142 1834 2.09 / 368.90 8 24
3 13 1915.84 20 14.56 3042 886 2.98 / 369.79 5 28
4 13 1593.32 20 14.55 2592 754 3.73 / 370.55 5 30
5 13 938.24 20 14.69 1719 505 4.24 / 371.05 5 38
6 13 483.28 20 14.85 1081 321 4.56 / 371.37 5 40
7 8 0.00 400 14.95 349 2087 6.64 / 373.46 5 28
Average= 8.89
(KJ/cycle)

Cycle 59 GMT 9/ 8/2023 17:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 36 14.95 496 267 0.27 / 360.68 6 8
2 7 2004.76 40 14.59 3128 1826 2.09 / 362.51 8 26
3 13 1915.72 20 14.56 3029 882 2.97 / 363.39 5 28
4 13 1374.12 20 14.61 2308 674 3.65 / 364.07 5 33
5 13 829.72 20 14.74 1564 461 4.11 / 364.53 5 39
6 13 46.24 20 15.05 424 128 4.24 / 364.65 5 22
7 13 26.60 20 15.04 396 119 4.36 / 364.77 5 16
8 8 -0.12 400 14.96 341 2041 6.40 / 366.81 5 35
Average= 8.95
(KJ/cycle)

Cycle 58 GMT 30/ 7/2023 20:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 36 14.96 491 264 0.26 / 354.13 6 8
2 7 2006.00 40 14.60 3116 1820 2.08 / 355.95 8 25
3 13 1918.88 20 14.57 3027 882 2.97 / 356.84 5 26
4 13 1494.08 20 14.58 2474 721 3.69 / 357.56 5 32
5 13 934.00 20 14.70 1714 504 4.19 / 358.06 5 37
6 13 163.72 20 15.00 612 184 4.38 / 358.24 5 34
7 13 16.88 20 15.05 383 115 4.49 / 358.36 5 13
8 8 -0.12 400 14.95 344 2057 6.55 / 360.42 5 31
Average= 9.01
(KJ/cycle)

Cycle 57 GMT 20/ 7/2023 23:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 35 14.95 483 253 0.25 / 347.89 6 7
2 7 2005.56 41 14.59 3128 1871 2.12 / 349.76 7 24
3 13 1919.72 20 14.56 3036 884 3.01 / 350.65 5 25
4 13 1289.16 20 14.64 2188 641 3.65 / 351.29 5 33
5 13 763.00 20 14.77 1461 432 4.08 / 351.72 5 39
6 13 54.44 20 15.05 435 131 4.21 / 351.85 5 24
7 8 0.04 400 14.97 337 2018 6.23 / 353.87 5 33
Average= 9.07
(KJ/cycle)

Cycle 56 GMT 11/ 7/2023 2:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 35 14.97 470 246 0.25 / 341.50 6 7
2 7 2003.92 40 14.60 3140 1834 2.08 / 343.33 7 25
3 13 1914.92 20 14.56 3044 886 2.97 / 344.22 5 28
4 13 1277.92 20 14.64 2180 638 3.60 / 344.85 5 34
5 13 757.20 20 14.77 1477 436 4.04 / 345.29 5 39
6 13 104.40 20 15.03 532 160 4.20 / 345.45 5 32
7 13 25.08 20 15.05 395 119 4.32 / 345.57 5 16
8 8 -0.12 400 14.96 346 2070 6.39 / 347.64 5 41
Average= 9.15
(KJ/cycle)

Cycle 55 GMT 1/ 7/2023 4:56: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 35 14.98 485 254 0.25 / 335.13 6 7
2 7 2003.28 40 14.60 3134 1830 2.08 / 336.96 7 25
3 13 1911.48 20 14.58 3028 883 2.97 / 337.85 5 29
4 13 1477.32 20 14.59 2449 715 3.68 / 338.56 5 33
5 13 718.00 20 14.80 1406 416 4.10 / 338.98 5 40
6 13 85.32 20 15.05 485 146 4.24 / 339.12 5 31
7 13 21.84 20 15.07 380 115 4.36 / 339.24 5 15
8 8 -0.04 400 14.98 336 2013 6.37 / 341.25 5 39
Average= 9.22
(KJ/cycle)

Cycle 54 GMT 21/ 6/2023 7:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 36 14.98 471 254 0.25 / 328.63 6 7
2 7 2014.92 40 14.59 3149 1838 2.09 / 330.47 7 24
3 13 1923.24 20 14.57 3040 886 2.98 / 331.35 5 27
4 13 1602.60 20 14.57 2622 764 3.74 / 332.12 5 33
5 13 817.68 20 14.77 1547 457 4.20 / 332.58 5 39
6 13 82.00 20 15.05 486 146 4.34 / 332.72 5 30
7 13 24.64 20 15.07 393 118 4.46 / 332.84 5 16
8 8 -0.16 400 14.98 340 2037 6.50 / 334.88 5 44
Average= 9.30
(KJ/cycle)

Cycle 53 GMT 11/ 6/2023 10:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 36 14.98 488 263 0.26 / 322.26 6 7
2 7 2005.16 40 14.61 3134 1832 2.09 / 324.09 7 24
3 13 1916.08 20 14.58 3031 884 2.98 / 324.97 5 27
4 13 1391.32 20 14.63 2335 683 3.66 / 325.65 5 33
5 13 760.44 20 14.79 1478 437 4.10 / 326.09 5 40
6 13 56.08 20 15.07 439 132 4.23 / 326.22 5 25
7 13 17.24 20 15.07 384 116 4.35 / 326.34 5 14
8 8 -0.04 400 14.98 340 2037 6.38 / 328.38 5 40
Average= 9.38
(KJ/cycle)

Cycle 52 GMT 1/ 6/2023 13:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 36 14.99 492 266 0.27 / 315.85 6 7
2 7 2014.44 40 14.59 3150 1838 2.10 / 317.69 7 25
3 13 1926.56 20 14.57 3045 887 2.99 / 318.57 5 27
4 13 1315.60 20 14.66 2226 653 3.64 / 319.23 5 34
5 13 786.24 20 14.79 1501 444 4.09 / 319.67 5 39
6 13 109.80 20 15.05 528 159 4.25 / 319.83 5 32
7 13 23.84 20 15.07 392 118 4.36 / 319.95 5 15
8 8 -0.08 400 14.99 341 2045 6.41 / 321.99 5 33
Average= 9.47
(KJ/cycle)

Cycle 51 GMT 22/ 5/2023 15:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 36 14.99 484 261 0.26 / 309.53 6 7
2 7 2006.68 40 14.61 3119 1823 2.08 / 311.36 7 23
3 13 1918.88 20 14.58 3030 884 2.97 / 312.24 5 28
4 13 1484.40 20 14.61 2453 717 3.68 / 312.96 5 33
5 13 739.96 20 14.81 1445 428 4.11 / 313.38 5 39
6 13 94.84 20 15.06 509 153 4.27 / 313.54 5 31
7 8 -0.12 400 15.00 341 2046 6.31 / 315.58 5 32
Average= 9.56
(KJ/cycle)

Cycle 50 GMT 12/ 5/2023 18:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 36 15.00 488 264 0.26 / 303.05 6 7
2 7 2006.36 40 14.61 3135 1832 2.10 / 304.89 7 25
3 13 1919.92 20 14.59 3043 888 2.98 / 305.77 5 27
4 13 1383.96 20 14.65 2327 682 3.67 / 306.46 5 34
5 13 833.52 20 14.78 1575 466 4.13 / 306.92 5 38
6 13 157.64 20 15.04 605 182 4.31 / 307.10 5 34
7 13 6.04 20 15.09 373 113 4.43 / 307.22 5 11
8 8 -0.20 400 14.99 343 2057 6.48 / 309.27 5 34
Average= 9.66
(KJ/cycle)

Cycle 49 GMT 2/ 5/2023 21:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 36 15.01 480 259 0.26 / 296.66 6 7
2 7 2014.20 40 14.61 3141 1836 2.09 / 298.50 7 23
3 13 1922.56 20 14.58 3041 887 2.98 / 299.38 5 26
4 13 1300.24 20 14.67 2205 647 3.63 / 300.03 5 34
5 13 866.56 20 14.77 1620 479 4.11 / 300.51 5 39
6 13 293.96 20 14.98 797 239 4.35 / 300.75 5 37
7 8 0.00 400 15.01 340 2041 6.39 / 302.79 5 34
Average= 9.77
(KJ/cycle)

Cycle 48 GMT 23/ 4/2023 0: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.16 36 15.01 482 260 0.26 / 290.28 6 7
2 7 2011.68 40 14.62 3145 1839 2.10 / 292.12 7 25
3 13 1915.16 20 14.59 3013 879 2.98 / 293.00 5 28
4 13 1381.00 20 14.66 2331 683 3.66 / 293.68 5 34
5 13 744.88 20 14.83 1455 432 4.09 / 294.11 5 39
6 13 51.64 20 15.10 431 130 4.22 / 294.24 5 23
7 13 13.28 20 15.10 372 112 4.34 / 294.35 5 12
8 8 0.20 400 15.01 341 2047 6.38 / 296.40 5 34
Average= 9.88
(KJ/cycle)

Cycle 47 GMT 13/ 4/2023 2:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.40 36 15.02 479 259 0.26 / 283.81 6 7
2 7 2011.68 40 14.62 3146 1840 2.10 / 285.65 7 23
3 13 1923.76 20 14.59 3035 886 2.98 / 286.54 5 29
4 13 1303.12 20 14.68 2216 651 3.64 / 287.19 5 34
5 13 875.72 20 14.79 1619 479 4.11 / 287.67 5 39
6 13 202.68 20 15.04 661 199 4.31 / 287.87 5 35
7 13 17.72 20 15.10 382 115 4.43 / 287.98 5 12
8 8 -0.20 400 15.01 339 2035 6.46 / 290.02 5 40
Average= 10.00
(KJ/cycle)

Cycle 46 GMT 3/ 4/2023 5:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 36 15.03 483 261 0.26 / 277.52 6 6
2 7 2012.88 40 14.61 3154 1843 2.10 / 279.36 6 25
3 13 1923.28 20 14.59 3039 887 2.99 / 280.25 5 28
4 13 1202.84 20 14.72 2077 611 3.60 / 280.86 5 36
5 13 691.64 20 14.86 1374 408 4.01 / 281.27 5 40
6 13 66.64 20 15.10 459 139 4.15 / 281.40 5 27
7 13 16.16 20 15.11 380 115 4.26 / 281.52 5 13
8 8 -0.28 400 15.02 339 2037 6.30 / 283.56 5 37
Average= 10.13
(KJ/cycle)

Cycle 45 GMT 24/ 3/2023 7:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.52 36 15.01 478 258 0.26 / 271.01 6 7
2 7 2006.44 40 14.62 3133 1832 2.09 / 272.84 7 25
3 13 1919.32 20 14.60 3029 884 2.97 / 273.72 5 28
4 13 1481.20 20 14.64 2457 719 3.69 / 274.44 5 32
5 13 822.88 20 14.82 1555 461 4.16 / 274.90 5 40
6 13 156.96 20 15.07 601 181 4.34 / 275.08 5 34
7 13 27.16 20 15.11 399 121 4.46 / 275.21 5 16
8 8 -0.12 400 15.02 341 2049 6.51 / 277.25 5 40
Average= 10.27
(KJ/cycle)

Cycle 44 GMT 14/ 3/2023 10:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 36 15.02 490 265 0.26 / 264.45 6 7
2 7 2012.56 40 14.62 3159 1847 2.11 / 266.30 7 24
3 13 1925.76 20 14.60 3033 886 3.00 / 267.18 5 27
4 13 1391.88 20 14.68 2330 684 3.68 / 267.87 5 35
5 13 851.16 20 14.82 1584 469 4.15 / 268.34 5 40
6 13 288.84 20 15.02 788 237 4.39 / 268.57 5 37
7 13 15.92 20 15.11 380 115 4.50 / 268.69 5 13
8 8 -0.12 400 15.02 343 2061 6.56 / 270.75 5 35
Average= 10.41
(KJ/cycle)

Cycle 43 GMT 4/ 3/2023 13:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.08 36 15.04 480 260 0.26 / 257.78 6 7
2 7 2005.72 40 14.64 3128 1832 2.09 / 259.61 7 24
3 13 1914.88 20 14.61 3031 886 2.98 / 260.50 5 26
4 13 1382.28 20 14.68 2343 688 3.67 / 261.19 5 33
5 13 836.80 20 14.82 1588 471 4.14 / 261.66 5 39
6 13 390.60 20 14.97 960 287 4.42 / 261.95 5 40
7 13 13.72 20 15.12 389 118 4.54 / 262.06 5 11
8 8 0.12 400 15.02 353 2121 6.66 / 264.18 5 34
Average= 10.57
(KJ/cycle)

Cycle 42 GMT 22/ 2/2023 16:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 36 15.04 494 267 0.27 / 251.23 6 7
2 7 2013.48 40 14.63 3151 1844 2.11 / 253.07 7 24
3 13 1921.60 20 14.60 3036 887 3.00 / 253.96 5 28
4 13 1490.00 20 14.66 2461 722 3.72 / 254.68 5 33
5 13 819.60 20 14.84 1539 457 4.18 / 255.14 5 40
6 13 257.04 20 15.04 742 223 4.40 / 255.36 5 36
7 13 14.92 20 15.13 381 115 4.51 / 255.48 5 12
8 8 -0.12 400 15.04 340 2045 6.56 / 257.52 5 44
Average= 10.73
(KJ/cycle)

Cycle 41 GMT 12/ 2/2023 19: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 35 15.04 486 256 0.26 / 244.67 6 7
2 7 2012.40 40 14.63 3152 1845 2.10 / 246.51 7 24
3 13 1915.92 20 14.61 3037 887 2.99 / 247.40 5 29
4 13 1384.76 20 14.69 2345 689 3.68 / 248.09 5 33
5 13 955.80 20 14.79 1761 521 4.20 / 248.61 5 39
6 13 89.28 20 15.11 507 153 4.35 / 248.76 5 30
7 13 17.16 20 15.13 389 118 4.47 / 248.88 5 13
8 8 -0.20 400 15.04 346 2082 6.55 / 250.96 5 40
Average= 10.91
(KJ/cycle)

Cycle 40 GMT 2/ 2/2023 21:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 35 15.06 468 247 0.25 / 238.18 6 6
2 7 2003.80 40 14.63 3137 1836 2.08 / 240.01 6 25
3 13 1912.04 20 14.62 3011 880 2.96 / 240.89 5 27
4 13 1483.80 20 14.67 2452 719 3.68 / 241.61 5 33
5 13 823.40 20 14.85 1550 460 4.14 / 242.07 5 40
6 13 76.56 20 15.12 481 145 4.29 / 242.22 5 29
7 13 16.56 20 15.14 385 117 4.40 / 242.34 5 13
8 8 -0.20 400 15.05 345 2077 6.48 / 244.41 5 38
Average= 11.11
(KJ/cycle)

Cycle 39 GMT 24/ 1/2023 0:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 35 15.07 469 247 0.25 / 231.83 6 7
2 7 2004.48 40 14.64 3125 1830 2.08 / 233.66 5 24
3 13 1911.28 20 14.62 3006 879 2.96 / 234.54 5 28
4 13 1372.20 20 14.71 2315 681 3.64 / 235.22 5 34
5 13 818.24 20 14.85 1537 456 4.09 / 235.68 5 40
6 13 39.48 20 15.15 407 123 4.22 / 235.80 5 20
7 13 13.12 20 15.15 369 112 4.33 / 235.91 5 12
8 8 -0.16 400 15.06 335 2018 6.35 / 237.93 5 42
Average= 11.33
(KJ/cycle)

Cycle 38 GMT 14/ 1/2023 3:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 35 15.06 462 244 0.24 / 225.47 6 7
2 7 2003.72 40 14.65 3134 1837 2.08 / 227.31 7 24
3 13 1913.52 20 14.63 3027 886 2.97 / 228.20 5 27
4 13 1288.04 20 14.75 2178 643 3.61 / 228.84 5 37
5 13 854.96 20 14.85 1595 474 4.08 / 229.31 5 39
6 13 49.44 20 15.15 430 130 4.21 / 229.44 5 23
7 13 19.36 20 15.15 384 116 4.33 / 229.56 5 15
8 8 -0.12 400 15.07 336 2025 6.35 / 231.58 5 43
Average= 11.58
(KJ/cycle)

Cycle 37 GMT 4/ 1/2023 6:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 35 15.07 476 251 0.25 / 219.10 6 7
2 7 2006.36 40 14.65 3136 1838 2.09 / 220.94 7 26
3 13 1921.40 20 14.63 3035 888 2.98 / 221.82 5 29
4 13 1382.80 20 14.71 2316 681 3.66 / 222.50 5 35
5 13 753.68 20 14.89 1466 437 4.09 / 222.94 5 40
6 13 45.52 20 15.15 424 128 4.22 / 223.07 5 22
7 13 16.20 20 15.15 383 116 4.34 / 223.19 5 14
8 8 -0.16 400 15.07 339 2043 6.38 / 225.23 5 42
Average= 11.85
(KJ/cycle)

Cycle 36 GMT 25/12/2022 8:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 35 15.07 487 257 0.26 / 212.68 6 8
2 7 2013.60 40 14.65 3148 1845 2.10 / 214.52 8 24
3 13 1925.24 20 14.63 3038 889 2.99 / 215.41 5 28
4 13 1401.36 20 14.72 2347 691 3.68 / 216.10 5 33
5 13 755.00 20 14.90 1461 435 4.12 / 216.54 5 40
6 13 99.48 20 15.14 506 153 4.27 / 216.69 5 31
7 13 20.12 20 15.16 383 116 4.39 / 216.81 5 14
8 8 -0.16 400 15.07 338 2037 6.42 / 218.85 5 38
Average= 12.16
(KJ/cycle)

Cycle 35 GMT 15/12/2022 11:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 35 15.08 482 254 0.25 / 206.16 6 8
2 7 2007.76 40 14.65 3131 1835 2.09 / 207.99 8 26
3 13 1923.96 20 14.63 3042 890 2.98 / 208.88 5 29
4 13 1394.52 20 14.72 2343 690 3.67 / 209.57 5 35
5 13 853.12 20 14.86 1605 477 4.15 / 210.05 5 39
6 13 184.56 20 15.11 644 195 4.34 / 210.25 5 35
7 13 13.52 20 15.16 383 116 4.46 / 210.36 5 11
8 8 -0.20 400 15.07 342 2062 6.52 / 212.42 5 35
Average= 12.50
(KJ/cycle)

Cycle 34 GMT 5/12/2022 14:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 35 15.08 495 261 0.26 / 199.72 6 8
2 7 2005.40 40 14.65 3130 1834 2.10 / 201.55 8 24
3 13 1919.60 20 14.64 3025 886 2.98 / 202.44 5 28
4 13 1386.12 20 14.73 2320 683 3.66 / 203.12 5 34
5 13 837.28 20 14.87 1572 468 4.13 / 203.59 5 40
6 13 78.52 20 15.15 484 147 4.28 / 203.74 5 30
7 13 17.60 20 15.17 384 117 4.40 / 203.85 5 14
8 8 -0.12 400 15.08 340 2051 6.45 / 205.90 5 38
Average= 12.87
(KJ/cycle)

Cycle 33 GMT 25/11/2022 17: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 35 15.08 488 258 0.26 / 193.38 6 8
2 7 2012.60 40 14.66 3143 1843 2.10 / 195.22 8 25
3 13 1918.00 20 14.64 3039 890 2.99 / 196.11 5 29
4 13 1392.00 20 14.74 2322 685 3.67 / 196.79 5 34
5 13 848.28 20 14.88 1589 473 4.15 / 197.27 5 40
6 13 89.60 20 15.15 497 151 4.30 / 197.42 5 31
7 8 -0.12 400 15.10 338 2042 6.34 / 199.46 5 35
Average= 13.30
(KJ/cycle)

Cycle 32 GMT 15/11/2022 19:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.52 35 15.08 484 255 0.26 / 187.00 6 9
2 7 2011.32 40 14.66 3142 1842 2.10 / 188.84 9 26
3 13 1913.40 20 14.66 3019 885 2.98 / 189.73 5 27
4 13 1378.76 20 14.75 2318 684 3.67 / 190.41 5 35
5 13 738.52 20 14.92 1438 429 4.10 / 190.84 5 40
6 13 42.00 20 15.18 412 125 4.22 / 190.97 5 20
7 13 12.32 20 15.18 372 113 4.33 / 191.08 5 13
8 8 -0.08 400 15.09 338 2040 6.37 / 193.12 5 36
Average= 13.79
(KJ/cycle)

Cycle 31 GMT 5/11/2022 22:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 35 15.08 497 262 0.26 / 180.61 6 8
2 7 2003.72 40 14.67 3133 1838 2.10 / 182.45 8 24
3 13 1909.92 20 14.66 3018 885 2.99 / 183.34 5 29
4 13 1471.16 20 14.72 2443 719 3.70 / 184.06 5 33
5 13 892.44 20 14.88 1647 490 4.20 / 184.55 5 39
6 13 53.24 20 15.18 436 132 4.33 / 184.68 5 23
7 8 -0.16 400 15.10 342 2066 6.39 / 186.74 5 32
Average= 14.36
(KJ/cycle)

Cycle 30 GMT 27/10/2022 1:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 35 15.09 479 253 0.25 / 174.34 6 8
2 7 2009.92 40 14.67 3149 1848 2.10 / 176.19 8 25
3 13 1913.92 20 14.67 3019 886 2.99 / 177.07 5 29
4 13 1292.52 20 14.78 2201 651 3.64 / 177.72 5 34
5 13 749.44 20 14.92 1456 434 4.07 / 178.16 5 40
6 13 52.32 20 15.18 435 132 4.20 / 178.29 5 23
7 8 -0.16 400 15.11 341 2061 6.26 / 180.35 5 31
Average= 15.03
(KJ/cycle)

Cycle 29 GMT 17/10/2022 4: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 35 15.09 500 264 0.26 / 168.04 6 8
2 7 2012.76 40 14.67 3146 1846 2.11 / 169.89 5 24
3 13 1915.80 20 14.66 3041 892 3.00 / 170.78 5 29
4 13 1376.80 20 14.77 2302 680 3.68 / 171.46 5 34
5 13 739.96 20 14.94 1442 431 4.11 / 171.89 5 40
6 13 24.20 20 15.20 392 119 4.23 / 172.01 5 13
7 8 -0.32 400 15.11 344 2079 6.31 / 174.09 5 32
Average= 15.83
(KJ/cycle)

Cycle 28 GMT 7/10/2022 6:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.72 35 15.09 503 266 0.27 / 161.57 6 9
2 7 2004.04 40 14.68 3136 1841 2.11 / 163.41 9 25
3 13 1912.20 20 14.68 3014 885 2.99 / 164.29 5 29
4 13 1373.56 20 14.77 2313 683 3.68 / 164.98 5 34
5 13 825.64 20 14.91 1560 465 4.14 / 165.44 5 40
6 13 78.60 20 15.18 482 146 4.29 / 165.59 5 30
7 13 18.44 20 15.19 386 117 4.40 / 165.70 5 13
8 8 -0.12 400 15.10 343 2072 6.48 / 167.78 5 38
Average= 16.78
(KJ/cycle)

Cycle 27 GMT 27/ 9/2022 9:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 35 15.10 501 265 0.26 / 155.09 6 9
2 7 2006.92 40 14.68 3144 1846 2.11 / 156.93 9 25
3 13 1909.84 20 14.67 3022 887 3.00 / 157.82 5 28
4 13 1380.52 20 14.77 2319 685 3.68 / 158.50 5 34
5 13 843.88 20 14.91 1584 472 4.15 / 158.98 5 40
6 13 88.96 20 15.18 500 152 4.31 / 159.13 5 32
7 13 17.92 20 15.19 385 117 4.42 / 159.24 5 12
8 8 -0.16 400 15.11 340 2055 6.48 / 161.30 5 36
Average= 17.92
(KJ/cycle)

Cycle 26 GMT 17/ 9/2022 12: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 35 15.09 494 261 0.26 / 148.63 6 10
2 7 2007.84 40 14.69 3139 1844 2.11 / 150.47 10 26
3 13 1920.04 20 14.67 3036 891 3.00 / 151.37 5 29
4 13 1379.68 20 14.77 2320 685 3.68 / 152.05 5 35
5 13 932.88 20 14.88 1703 507 4.19 / 152.56 5 40
6 13 144.28 20 15.16 584 177 4.37 / 152.73 5 35
7 8 -0.12 400 15.12 345 2087 6.45 / 154.82 5 30
Average= 19.35
(KJ/cycle)

Cycle 25 GMT 7/ 9/2022 15: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.00 35 15.10 493 261 0.26 / 142.26 6 10
2 7 2005.04 41 14.69 3132 1886 2.15 / 144.14 10 26
3 13 1916.40 20 14.68 3043 893 3.04 / 145.04 5 29
4 13 1281.56 20 14.81 2198 651 3.69 / 145.69 5 36
5 13 752.40 20 14.95 1464 438 4.13 / 146.13 5 41
6 13 97.20 20 15.18 515 156 4.29 / 146.28 5 33
7 8 -0.24 400 15.12 345 2087 6.37 / 148.37 5 29
Average= 21.20
(KJ/cycle)

Cycle 24 GMT 28/ 8/2022 17:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 35 15.11 507 268 0.27 / 135.91 6 10
2 7 2003.32 40 14.69 3133 1841 2.11 / 137.76 10 26
3 13 1906.28 20 14.69 3027 889 3.00 / 138.64 5 30
4 13 1274.72 20 14.82 2171 643 3.64 / 139.29 5 36
5 13 840.64 20 14.92 1579 471 4.11 / 139.76 5 41
6 13 148.44 20 15.16 595 180 4.29 / 139.94 5 36
7 8 -0.16 400 15.13 340 2058 6.35 / 142.00 5 29
Average= 23.67
(KJ/cycle)

Cycle 23 GMT 18/ 8/2022 20:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 35 15.11 498 263 0.26 / 129.55 6 10
2 7 2012.08 40 14.69 3157 1855 2.12 / 131.41 10 27
3 13 1914.28 20 14.69 3026 889 3.01 / 132.29 5 29
4 13 1294.04 20 14.81 2206 653 3.66 / 132.95 5 36
5 13 872.72 20 14.91 1624 484 4.15 / 133.43 5 40
6 13 96.84 20 15.19 515 156 4.30 / 133.59 5 33
7 8 -0.12 400 15.13 340 2058 6.36 / 135.65 5 33
Average= 27.13
(KJ/cycle)

Cycle 22 GMT 8/ 8/2022 23:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.76 34 15.11 496 255 0.25 / 123.16 6 11
2 7 2003.56 40 14.69 3134 1842 2.10 / 125.01 11 27
3 13 1914.48 20 14.70 3028 890 2.99 / 125.90 5 29
4 13 1379.64 20 14.79 2324 687 3.67 / 126.58 5 35
5 13 935.60 20 14.89 1718 512 4.19 / 127.10 5 40
6 13 38.52 20 15.21 414 126 4.31 / 127.22 5 21
7 8 -0.04 400 15.14 341 2065 6.38 / 129.29 5 33
Average= 32.32
(KJ/cycle)

Cycle 21 GMT 30/ 7/2022 2: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 34 15.11 496 255 0.25 / 116.85 6 9
2 7 2010.80 40 14.70 3147 1850 2.11 / 118.70 9 27
3 13 1921.16 20 14.70 3043 895 3.00 / 119.59 5 30
4 13 1372.76 20 14.80 2307 683 3.68 / 120.27 5 35
5 13 630.12 20 15.00 1294 388 4.07 / 120.66 5 42
6 13 88.32 20 15.19 505 153 4.22 / 120.82 5 32
7 8 -0.08 400 15.13 346 2094 6.32 / 122.91 5 29
Average= 40.97
(KJ/cycle)

Cycle 20 GMT 20/ 7/2022 4:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 35 15.12 492 260 0.26 / 110.40 6 9
2 7 2007.72 40 14.71 3135 1845 2.11 / 112.24 9 27
3 13 1913.08 20 14.70 3026 890 2.99 / 113.13 5 30
4 13 1297.88 20 14.82 2214 656 3.65 / 113.79 5 36
5 13 762.56 20 14.96 1483 444 4.09 / 114.23 5 42
6 13 49.28 20 15.21 442 134 4.23 / 114.37 5 24
7 13 12.72 20 15.22 386 117 4.35 / 114.49 5 13
8 8 -0.20 400 15.13 348 2106 6.45 / 116.59 5 42
Average= 58.30
(KJ/cycle)

Cycle 19 GMT 10/ 7/2022 7:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 35 15.14 482 255 0.26 / 104.10 6 8
2 7 2012.84 40 14.70 3146 1850 2.11 / 105.95 8 27
3 13 1922.80 20 14.70 3032 891 3.00 / 106.84 5 30
4 13 1294.20 20 14.82 2211 655 3.65 / 107.50 5 36
5 13 671.68 20 14.99 1354 406 4.06 / 107.90 5 42
6 13 54.56 20 15.21 449 137 4.19 / 108.04 5 26
7 8 -0.08 400 15.14 347 2101 6.30 / 110.14 5 35
Average= 110.14
(KJ/cycle)

Cycle 17 GMT 20/ 6/2022 12:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 35 15.13 468 248 0.25 / 97.82 6 8
2 7 2014.88 40 14.71 3148 1852 2.10 / 99.67 8 26
3 13 1924.48 20 14.72 3033 893 2.99 / 100.56 5 29
4 13 1299.44 20 14.83 2215 657 3.65 / 101.22 5 36
5 13 749.20 20 14.97 1463 438 4.09 / 101.66 5 43
6 13 41.28 20 15.23 418 127 4.22 / 101.78 5 22
7 8 0.00 400 15.15 340 2060 6.28 / 103.84 5 44
Average= 5.77
(KJ/cycle)

Cycle 16 GMT 10/ 6/2022 15:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 35 15.14 471 250 0.25 / 91.38 6 8
2 7 2012.04 40 14.72 3153 1856 2.11 / 93.23 8 26
3 13 1918.60 20 14.72 3046 897 3.00 / 94.13 5 30
4 13 1390.88 20 14.81 2338 693 3.70 / 94.82 5 35
5 13 752.28 20 14.97 1466 439 4.13 / 95.26 5 43
6 13 93.84 20 15.21 502 153 4.29 / 95.41 5 33
7 13 21.12 20 15.23 387 118 4.40 / 95.53 5 17
8 8 -0.16 400 15.15 336 2036 6.44 / 97.57 5 41
Average= 5.74
(KJ/cycle)

Cycle 15 GMT 31/ 5/2022 18: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 35 15.15 488 259 0.26 / 85.11 6 8
2 7 2009.56 40 14.73 3143 1852 2.11 / 86.96 8 27
3 13 1922.68 20 14.72 3049 898 3.01 / 87.86 5 30
4 13 1290.68 20 14.84 2209 656 3.66 / 88.51 5 36
5 13 661.16 20 15.00 1353 406 4.07 / 88.92 5 43
6 13 56.52 20 15.23 454 138 4.21 / 89.06 5 27
7 8 -0.12 400 15.16 341 2068 6.28 / 91.13 5 40
Average= 5.70
(KJ/cycle)

Cycle 14 GMT 21/ 5/2022 20:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.00 35 15.14 469 249 0.25 / 78.78 6 8
2 7 2005.68 40 14.73 3136 1848 2.10 / 80.62 8 27
3 13 1915.32 20 14.73 3045 897 2.99 / 81.52 5 30
4 13 1297.40 20 14.84 2211 656 3.65 / 82.18 5 36
5 13 857.76 20 14.94 1612 482 4.13 / 82.66 5 42
6 13 45.12 20 15.24 425 130 4.26 / 82.79 5 23
7 8 -0.04 400 15.16 340 2062 6.32 / 84.85 5 44
Average= 5.66
(KJ/cycle)

Cycle 13 GMT 11/ 5/2022 23:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 35 15.15 468 248 0.25 / 72.24 6 7
2 7 2013.56 40 14.74 3147 1855 2.10 / 74.10 7 26
3 13 1922.04 20 14.74 3044 897 3.00 / 74.99 5 30
4 13 1485.24 20 14.79 2462 728 3.73 / 75.72 5 35
5 13 909.88 20 14.93 1688 504 4.23 / 76.23 5 42
6 13 59.08 20 15.24 447 136 4.37 / 76.36 5 26
7 13 16.00 20 15.24 383 117 4.49 / 76.48 5 15
8 8 -0.20 400 15.16 338 2050 6.54 / 78.53 5 42
Average= 5.61
(KJ/cycle)

Cycle 12 GMT 2/ 5/2022 2: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 35 15.15 477 253 0.25 / 65.89 6 8
2 7 2008.72 40 14.74 3150 1857 2.11 / 67.75 8 27
3 13 1910.92 20 14.74 3022 891 3.00 / 68.64 5 30
4 13 1357.32 20 14.84 2285 678 3.68 / 69.32 5 36
5 13 608.36 20 15.04 1271 382 4.06 / 69.70 5 43
6 13 43.60 20 15.24 426 130 4.19 / 69.83 5 23
7 13 12.60 20 15.24 374 114 4.31 / 69.94 5 14
8 8 -0.08 400 15.16 338 2050 6.36 / 71.99 5 44
Average= 5.54
(KJ/cycle)

Cycle 11 GMT 22/ 4/2022 4:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 35 15.17 467 248 0.25 / 59.60 6 7
2 7 2005.16 40 14.75 3132 1848 2.10 / 61.45 7 27
3 13 1923.36 20 14.75 3044 898 2.99 / 62.34 5 30
4 13 1189.72 20 14.88 2057 612 3.61 / 62.96 5 37
5 13 659.36 20 15.02 1340 403 4.01 / 63.36 5 43
6 13 47.60 20 15.24 421 128 4.14 / 63.49 5 24
7 13 14.48 20 15.25 372 113 4.25 / 63.60 5 16
8 8 -0.28 400 15.16 336 2038 6.29 / 65.64 5 45
Average= 5.47
(KJ/cycle)

Cycle 10 GMT 12/ 4/2022 7:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 35 15.16 463 246 0.25 / 53.28 6 7
2 7 2014.16 40 14.75 3147 1857 2.10 / 55.14 7 26
3 13 1923.04 20 14.74 3035 895 3.00 / 56.04 5 30
4 13 1298.00 20 14.86 2206 656 3.65 / 56.69 5 37
5 13 869.88 20 14.95 1629 487 4.14 / 57.18 5 42
6 13 51.52 20 15.25 434 132 4.27 / 57.31 5 26
7 8 -0.16 400 15.17 336 2039 6.31 / 59.35 5 52
Average= 5.40
(KJ/cycle)

Cycle 9 GMT 2/ 4/2022 9:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 34 15.16 467 241 0.24 / 46.75 6 7
2 7 2013.24 40 14.76 3148 1859 2.10 / 48.61 7 27
3 13 1918.60 20 14.75 3040 897 3.00 / 49.50 5 30
4 13 1388.68 20 14.83 2336 693 3.69 / 50.19 5 36
5 13 841.92 20 14.96 1593 477 4.17 / 50.67 5 42
6 13 157.00 20 15.20 603 183 4.35 / 50.85 5 36
7 13 29.64 20 15.24 399 122 4.47 / 50.98 5 21
8 8 -0.20 400 15.16 340 2062 6.53 / 53.04 5 45
Average= 5.30
(KJ/cycle)

Cycle 8 GMT 23/ 3/2022 12:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 34 15.17 444 229 0.23 / 40.42 6 7
2 7 2013.16 40 14.76 3139 1853 2.08 / 42.27 7 28
3 13 1925.68 20 14.76 3016 890 2.97 / 43.16 5 30
4 13 1293.48 20 14.87 2183 649 3.62 / 43.81 5 37
5 13 749.92 20 15.00 1442 433 4.05 / 44.24 5 43
6 13 84.36 20 15.24 467 142 4.20 / 44.39 5 31
7 13 18.88 20 15.26 360 110 4.31 / 44.50 5 16
8 8 -0.20 400 15.18 331 2010 6.32 / 46.51 5 50
Average= 5.17
(KJ/cycle)

Cycle 7 GMT 13/ 3/2022 15:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 34 15.17 459 237 0.24 / 34.13 6 7
2 3 1021.36 1 15.18 1841 28 0.26 / 34.15 5 8
3 7 2011.36 40 14.77 3136 1853 2.12 / 36.01 8 28
4 13 1919.00 20 14.77 3010 889 3.01 / 36.90 5 30
5 13 1385.08 20 14.85 2310 686 3.69 / 37.58 5 36
6 13 732.56 20 15.01 1422 427 4.12 / 38.01 5 43
7 13 85.52 20 15.24 469 143 4.26 / 38.15 5 32
8 13 22.32 20 15.26 368 112 4.37 / 38.26 5 18
9 8 -0.24 400 15.18 317 1925 6.30 / 40.19 5 43
Average= 5.02
(KJ/cycle)

Cycle 6 GMT 3/ 3/2022 18: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 33 15.17 441 221 0.22 / 27.91 6 7
2 3 1037.60 1 15.17 1848 28 0.25 / 27.94 5 18
3 7 2012.48 40 14.78 3123 1846 2.10 / 29.78 18 28
4 13 1919.52 20 14.77 3009 889 2.98 / 30.67 5 30
5 13 1289.16 20 14.88 2183 650 3.63 / 31.32 5 37
6 13 762.04 20 15.00 1464 439 4.07 / 31.76 5 43
7 13 46.28 20 15.26 397 121 4.19 / 31.88 5 23
8 13 17.04 20 15.26 353 108 4.30 / 31.99 5 15
9 8 -0.20 400 15.18 313 1901 6.20 / 33.89 5 41
Average= 4.84
(KJ/cycle)

Cycle 5 GMT 21/ 2/2022 20:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 31 15.18 453 213 0.21 / 21.62 6 7
2 3 1069.92 2 15.13 1895 57 0.27 / 21.68 5 28
3 7 2011.72 40 14.78 3126 1848 2.12 / 23.53 28 28
4 13 1917.32 20 14.78 3009 889 3.01 / 24.42 5 31
5 13 1469.88 20 14.83 2412 715 3.72 / 25.13 5 35
6 13 699.36 20 15.03 1372 412 4.14 / 25.54 5 43
7 13 36.88 20 15.27 386 118 4.25 / 25.66 5 21
8 13 12.48 20 15.26 348 106 4.36 / 25.77 5 15
9 8 -0.20 400 15.18 316 1919 6.28 / 27.69 5 45
Average= 4.61
(KJ/cycle)

Cycle 4 GMT 11/ 2/2022 23:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 33 15.18 444 222 0.22 / 16.23 6 7
2 7 1509.84 40 14.97 2437 1459 1.68 / 17.69 5 31
3 13 1429.32 20 14.95 2346 701 2.38 / 18.39 5 34
4 13 1239.56 20 14.95 2084 623 3.01 / 19.02 5 37
5 13 585.80 20 15.09 1215 367 3.37 / 19.38 5 43
6 13 31.32 20 15.28 376 115 3.49 / 19.50 5 19
7 8 -0.12 400 15.21 314 1910 5.40 / 21.41 5 41
Average= 4.28
(KJ/cycle)

Cycle 3 GMT 10/ 2/2022 13:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 32 15.16 445 216 0.22 / 10.84 6 8
2 3 1019.76 1 15.19 1826 28 0.24 / 10.87 5 10
3 7 1505.40 40 14.97 2436 1459 1.70 / 12.32 10 32
4 13 1426.20 20 14.96 2334 698 2.40 / 13.02 5 34
5 13 1225.80 20 14.95 2082 623 3.02 / 13.64 5 37
6 13 566.84 20 15.10 1182 357 3.38 / 14.00 5 44
7 13 14.52 20 15.29 347 106 3.49 / 14.11 5 14
8 8 -0.08 400 15.20 313 1903 5.39 / 16.01 5 45
Average= 4.00
(KJ/cycle)

Cycle 2 GMT 9/ 2/2022 3: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.52 31 15.20 457 215 0.22 / 5.41 6 7
2 3 1066.96 2 15.16 1885 57 0.27 / 5.47 5 28
3 7 1506.04 40 14.96 2446 1464 1.74 / 6.93 28 30
4 13 1428.52 20 14.95 2343 701 2.44 / 7.63 5 33
5 13 1126.68 20 14.98 1939 581 3.02 / 8.21 5 37
6 13 591.32 20 15.09 1217 367 3.38 / 8.58 5 43
7 13 56.72 20 15.26 416 127 3.51 / 8.71 5 27
8 8 -0.12 400 15.19 315 1914 5.43 / 10.62 5 42
Average= 3.54
(KJ/cycle)

Cycle 1 GMT 7/ 2/2022 16:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 31 15.45 405 194 0.19 / 1.74 6 6
2 10 1015.88 3 15.20 1800 82 0.28 / 1.83 5 25
3 7 988.16 40 15.10 1745 1054 1.33 / 2.88 25 37
4 13 473.96 20 15.22 1040 317 1.65 / 3.20 5 41
5 13 27.68 20 15.34 365 112 1.76 / 3.31 5 19
6 8 -0.12 400 15.26 309 1886 3.64 / 5.20 5 47
Average= 2.60
(KJ/cycle)

Cycle 0 GMT 7/ 2/2022 6: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 53.60 30 15.62 338 158 0.16 / 0.16 6 7
2 7 63.12 41 15.60 343 219 0.38 / 0.38 7 9
3 13 44.44 20 15.59 318 99 0.48 / 0.48 6 9
4 13 26.40 20 15.58 292 91 0.57 / 0.57 6 13
5 8 -0.04 253 15.54 250 983 1.55 / 1.55 6 -99
Average= 1.55
(KJ/cycle)