SIO Argo Site:
Pump Diagnostics Page   



Serial= 7696 WMO= 1902421

Return

←PreviousNext→

Cycle 87 GMT 27/ 4/2024 1:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 38 14.99 463 264 0.26 / 477.26 5 7
2 7 2006.24 40 14.68 3062 1798 2.06 / 479.06 7 21
3 13 1881.12 20 14.67 2918 856 2.92 / 479.91 5 26
4 13 1444.60 20 14.70 2345 689 3.61 / 480.60 5 32
5 13 851.32 20 14.82 1561 463 4.07 / 481.06 5 37
6 13 254.28 20 15.00 733 220 4.29 / 481.28 5 38
7 13 23.60 20 15.07 385 116 4.41 / 481.40 5 29
8 8 -0.20 295 15.01 332 1470 5.88 / 482.87 5 140
Average= 7.10
(KJ/cycle)

Cycle 86 GMT 17/ 4/2024 6:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 38 14.98 464 264 0.26 / 471.25 5 7
2 7 2004.52 40 14.68 3081 1809 2.07 / 473.05 7 25
3 13 1868.64 20 14.67 2913 855 2.93 / 473.91 5 28
4 13 1562.76 20 14.67 2504 735 3.66 / 474.64 5 30
5 13 933.32 20 14.79 1679 497 4.16 / 475.14 5 37
6 13 310.72 20 14.98 819 245 4.40 / 475.39 5 40
7 13 33.24 20 15.07 398 120 4.52 / 475.51 5 32
8 8 -0.16 297 15.00 334 1488 6.01 / 476.99 5 138
Average= 7.12
(KJ/cycle)

Cycle 85 GMT 7/ 4/2024 11:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 38 14.98 466 265 0.27 / 465.18 5 7
2 7 2011.80 40 14.68 3081 1809 2.07 / 466.99 7 27
3 13 1887.04 20 14.66 2920 856 2.93 / 467.85 5 27
4 13 1600.96 20 14.66 2549 747 3.68 / 468.59 5 33
5 13 834.64 20 14.83 1550 460 4.14 / 469.05 5 38
6 13 393.24 20 14.95 939 281 4.42 / 469.33 5 41
7 13 42.08 20 15.06 413 124 4.54 / 469.46 5 35
8 8 -0.36 304 15.00 334 1523 6.07 / 470.98 5 146
Average= 7.14
(KJ/cycle)

Cycle 84 GMT 28/ 3/2024 16:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 38 14.99 462 263 0.26 / 459.12 5 7
2 7 2019.00 41 14.67 3094 1861 2.12 / 460.98 7 24
3 13 1896.76 20 14.66 2920 856 2.98 / 461.84 5 29
4 13 1440.52 20 14.69 2352 691 3.67 / 462.53 5 33
5 13 983.00 20 14.77 1759 520 4.19 / 463.05 5 38
6 13 351.56 20 14.95 878 263 4.45 / 463.31 5 42
7 8 -0.04 325 15.00 329 1604 6.06 / 464.92 5 131
Average= 7.15
(KJ/cycle)

Cycle 83 GMT 18/ 3/2024 22: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.36 38 15.00 453 258 0.26 / 453.02 5 7
2 7 2012.44 40 14.68 3076 1806 2.06 / 454.83 7 23
3 13 1883.08 20 14.66 2938 861 2.93 / 455.69 5 27
4 13 1584.44 20 14.66 2528 741 3.67 / 456.43 5 31
5 13 1112.36 20 14.74 1920 566 4.23 / 457.00 5 35
6 13 320.28 20 14.97 840 251 4.48 / 457.25 5 40
7 8 -0.12 319 15.01 336 1609 6.09 / 458.86 5 138
Average= 7.17
(KJ/cycle)

Cycle 82 GMT 9/ 3/2024 3:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 38 14.99 453 258 0.26 / 447.20 5 7
2 7 2013.20 40 14.67 3081 1808 2.07 / 449.00 7 24
3 13 1890.60 20 14.66 2924 857 2.92 / 449.86 5 28
4 13 1454.12 20 14.69 2366 695 3.62 / 450.56 5 31
5 13 849.08 20 14.82 1556 461 4.08 / 451.02 5 38
6 13 128.52 20 15.04 547 165 4.24 / 451.18 5 38
7 13 27.96 20 15.07 391 118 4.36 / 451.30 5 31
8 8 -0.24 293 15.01 333 1465 5.83 / 452.76 5 135
Average= 7.19
(KJ/cycle)

Cycle 81 GMT 28/ 2/2024 8:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 38 14.99 465 265 0.26 / 441.24 5 7
2 7 2005.72 41 14.68 3071 1848 2.11 / 443.09 7 24
3 13 1872.64 20 14.67 2911 854 2.97 / 443.94 5 29
4 13 1579.76 20 14.66 2526 741 3.71 / 444.68 5 30
5 13 959.04 20 14.78 1706 504 4.21 / 445.19 5 38
6 13 194.00 20 15.02 635 191 4.40 / 445.38 5 39
7 8 -0.12 314 15.01 331 1560 5.96 / 446.94 5 129
Average= 7.21
(KJ/cycle)

Cycle 80 GMT 18/ 2/2024 13:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.80 38 14.99 461 263 0.26 / 435.23 5 7
2 7 2018.64 40 14.68 3091 1815 2.08 / 437.05 7 23
3 13 1886.20 20 14.66 2919 856 2.93 / 437.90 5 25
4 13 1450.36 20 14.70 2363 695 3.63 / 438.60 5 35
5 13 858.24 20 14.82 1584 469 4.10 / 439.07 5 39
6 13 405.72 20 14.94 955 285 4.38 / 439.35 5 41
7 8 -0.36 325 15.00 333 1623 6.01 / 440.98 5 142
Average= 7.23
(KJ/cycle)

Cycle 79 GMT 8/ 2/2024 18:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.04 38 14.99 457 260 0.26 / 429.26 5 7
2 7 2020.92 41 14.68 3083 1856 2.12 / 431.11 12 24
3 13 1899.48 20 14.67 2930 860 2.98 / 431.97 5 29
4 13 1458.56 20 14.69 2352 691 3.67 / 432.66 5 33
5 13 990.28 20 14.77 1751 517 4.18 / 433.18 5 37
6 13 209.48 20 15.02 654 196 4.38 / 433.38 5 40
7 13 19.72 20 15.07 359 108 4.49 / 433.48 5 27
8 8 -0.20 300 15.00 330 1485 5.97 / 434.97 5 133
Average= 7.25
(KJ/cycle)

Cycle 78 GMT 29/ 1/2024 23:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 38 14.99 461 263 0.26 / 423.30 5 7
2 7 2006.24 40 14.69 3062 1799 2.06 / 425.10 7 24
3 13 1878.28 20 14.68 2904 853 2.91 / 425.95 5 25
4 13 1433.92 20 14.70 2351 691 3.61 / 426.64 5 31
5 13 834.52 20 14.83 1533 455 4.06 / 427.10 5 38
6 13 370.72 20 14.96 906 271 4.33 / 427.37 5 42
7 8 -0.16 323 15.00 336 1628 5.96 / 429.00 5 132
Average= 7.27
(KJ/cycle)

Cycle 77 GMT 20/ 1/2024 4:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 37 14.98 471 261 0.26 / 417.36 5 7
2 7 2020.40 40 14.68 3088 1813 2.07 / 419.17 7 23
3 13 1896.84 20 14.66 2937 861 2.94 / 420.03 5 28
4 13 1458.44 20 14.69 2369 696 3.63 / 420.73 5 31
5 13 855.80 20 14.82 1563 463 4.09 / 421.19 5 37
6 13 248.52 20 15.00 713 214 4.31 / 421.41 5 41
7 8 -0.16 323 15.01 336 1629 5.94 / 423.04 5 136
Average= 7.29
(KJ/cycle)

Cycle 76 GMT 10/ 1/2024 9:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 37 14.99 457 253 0.25 / 411.24 5 8
2 7 2008.28 40 14.68 3079 1808 2.06 / 413.05 22 23
3 13 1882.92 20 14.67 2911 854 2.92 / 413.90 5 26
4 13 1600.88 20 14.66 2549 747 3.66 / 414.65 5 30
5 13 1098.24 20 14.74 1910 563 4.23 / 415.21 5 37
6 13 299.40 20 14.98 807 242 4.47 / 415.45 5 40
7 8 -0.08 317 15.00 346 1645 6.11 / 417.10 5 139
Average= 7.32
(KJ/cycle)

Cycle 75 GMT 31/12/2023 15: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 37 14.98 461 256 0.26 / 405.28 5 7
2 7 2011.84 40 14.69 3076 1807 2.06 / 407.09 7 24
3 13 1888.00 20 14.68 2922 858 2.92 / 407.95 5 28
4 13 1451.72 20 14.70 2352 691 3.61 / 408.64 5 31
5 13 993.72 20 14.78 1757 519 4.13 / 409.16 5 37
6 13 223.80 20 15.01 681 204 4.34 / 409.36 5 39
7 8 -0.16 325 15.01 333 1624 5.96 / 410.99 5 140
Average= 7.34
(KJ/cycle)

Cycle 74 GMT 21/12/2023 20: 9: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 37 14.99 455 252 0.25 / 399.26 5 8
2 7 2011.48 40 14.69 3082 1811 2.06 / 401.07 8 23
3 13 1886.84 20 14.68 2930 860 2.92 / 401.93 5 27
4 13 1443.72 20 14.70 2340 688 3.61 / 402.62 5 31
5 13 847.76 20 14.82 1555 461 4.07 / 403.08 5 37
6 13 391.48 20 14.95 940 281 4.35 / 403.36 5 42
7 8 -0.24 332 15.00 334 1663 6.02 / 405.02 5 136
Average= 7.36
(KJ/cycle)

Cycle 73 GMT 12/12/2023 1:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 37 14.99 455 252 0.25 / 393.32 5 7
2 7 2005.64 40 14.69 3091 1816 2.07 / 395.13 7 26
3 13 1881.04 20 14.67 2920 857 2.93 / 395.99 5 26
4 13 1444.92 20 14.70 2362 694 3.62 / 396.69 5 32
5 13 853.04 20 14.82 1558 462 4.08 / 397.15 5 37
6 13 244.60 20 15.01 705 212 4.29 / 397.36 5 41
7 8 -0.28 327 15.01 336 1649 5.94 / 399.01 5 139
Average= 7.39
(KJ/cycle)

Cycle 72 GMT 2/12/2023 6:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 37 14.99 483 268 0.27 / 387.39 5 8
2 3 1018.80 1 15.07 1812 27 0.30 / 387.42 5 22
3 7 2007.12 40 14.70 3057 1798 2.09 / 389.22 22 24
4 13 1887.12 20 14.68 2912 855 2.95 / 390.07 5 26
5 13 1441.28 20 14.71 2345 690 3.64 / 390.76 5 33
6 13 844.80 20 14.82 1559 462 4.10 / 391.23 5 39
7 13 239.48 20 15.01 700 210 4.31 / 391.44 5 41
8 8 -0.04 329 15.01 330 1630 5.94 / 393.07 5 138
Average= 7.42
(KJ/cycle)

Cycle 71 GMT 22/11/2023 11:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 36 14.98 476 257 0.26 / 381.38 5 9
2 7 2015.92 41 14.69 3094 1863 2.12 / 383.24 9 25
3 13 1891.40 20 14.68 2919 857 2.98 / 384.10 5 26
4 13 1438.24 20 14.71 2338 688 3.67 / 384.79 5 33
5 13 842.40 20 14.83 1552 460 4.13 / 385.25 5 38
6 13 222.56 20 15.02 697 209 4.33 / 385.46 5 40
7 8 -0.08 327 15.01 340 1669 6.00 / 387.13 5 134
Average= 7.44
(KJ/cycle)

Cycle 70 GMT 12/11/2023 16:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.16 36 14.99 457 247 0.25 / 375.30 5 8
2 7 2009.24 40 14.70 3071 1806 2.05 / 377.11 8 24
3 13 1889.28 20 14.68 2921 858 2.91 / 377.96 5 29
4 13 1326.56 20 14.74 2206 650 3.56 / 378.61 5 32
5 13 879.04 20 14.82 1607 476 4.04 / 379.09 5 38
6 13 407.84 20 14.95 976 292 4.33 / 379.38 5 42
7 8 -0.12 338 15.01 343 1740 6.07 / 381.12 5 148
Average= 7.47
(KJ/cycle)

Cycle 69 GMT 2/11/2023 21:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 36 14.98 468 252 0.25 / 369.32 5 10
2 7 2004.44 40 14.70 3067 1803 2.06 / 371.13 10 24
3 13 1872.40 20 14.69 2907 854 2.91 / 371.98 5 26
4 13 1582.20 20 14.68 2519 740 3.65 / 372.72 5 32
5 13 932.88 20 14.80 1667 493 4.14 / 373.21 5 36
6 13 169.84 20 15.04 596 179 4.32 / 373.39 5 39
7 8 -0.16 329 15.02 336 1660 5.98 / 375.05 5 142
Average= 7.50
(KJ/cycle)

Cycle 68 GMT 24/10/2023 2:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 36 15.00 470 254 0.25 / 363.19 5 10
2 7 2018.72 40 14.70 3079 1810 2.06 / 365.00 10 24
3 13 1888.36 20 14.69 2924 859 2.92 / 365.86 5 27
4 13 1441.32 20 14.72 2332 687 3.61 / 366.54 5 32
5 13 968.68 20 14.80 1717 508 4.12 / 367.05 5 39
6 13 475.92 20 14.92 1071 320 4.44 / 367.37 5 41
7 8 -0.12 336 15.01 337 1700 6.14 / 369.07 5 142
Average= 7.53
(KJ/cycle)

Cycle 67 GMT 14/10/2023 7:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 36 15.00 471 254 0.25 / 357.28 5 9
2 7 2015.36 40 14.71 3080 1812 2.07 / 359.09 9 24
3 13 1880.84 20 14.69 2910 855 2.92 / 359.95 5 25
4 13 1444.96 20 14.72 2347 691 3.61 / 360.64 5 32
5 13 859.60 20 14.83 1573 467 4.08 / 361.10 5 37
6 13 140.24 20 15.06 569 171 4.25 / 361.27 5 37
7 8 -0.16 329 15.02 336 1660 5.91 / 362.93 5 150
Average= 7.56
(KJ/cycle)

Cycle 66 GMT 4/10/2023 12:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 36 15.00 481 260 0.26 / 351.26 5 9
2 7 2007.16 40 14.70 3083 1813 2.07 / 353.07 18 23
3 13 1876.36 20 14.70 2913 856 2.93 / 353.92 5 30
4 13 1582.36 20 14.68 2540 746 3.67 / 354.67 5 32
5 13 827.88 20 14.84 1544 458 4.13 / 355.13 5 38
6 13 212.56 20 15.03 680 204 4.34 / 355.33 5 40
7 8 -0.20 332 15.02 339 1690 6.03 / 357.02 5 139
Average= 7.60
(KJ/cycle)

Cycle 65 GMT 24/ 9/2023 17:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 37 15.00 470 261 0.26 / 345.23 5 9
2 3 964.88 -1 15.41 3 0 0.00 / 345.23 5 9
3 7 2005.72 40 14.71 3084 1815 2.08 / 347.04 9 23
4 13 1879.44 20 14.70 2913 856 2.93 / 347.90 5 27
5 13 1590.88 20 14.69 2552 750 3.68 / 348.65 5 33
6 13 828.04 20 14.84 1562 464 4.15 / 349.11 5 39
7 13 230.12 20 15.03 709 213 4.36 / 349.32 5 39
8 8 -0.16 329 15.03 338 1671 6.03 / 351.00 5 138
Average= 7.63
(KJ/cycle)

Cycle 64 GMT 14/ 9/2023 22:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 37 15.00 494 274 0.27 / 339.13 5 9
2 3 1027.32 1 15.07 1845 28 0.30 / 339.16 5 28
3 7 2011.00 40 14.71 3075 1809 2.11 / 340.97 28 24
4 13 1878.48 20 14.70 2899 852 2.96 / 341.82 5 28
5 13 1429.88 20 14.73 2329 686 3.65 / 342.51 5 34
6 13 964.52 20 14.81 1712 507 4.16 / 343.02 5 37
7 13 339.40 20 15.00 844 253 4.41 / 343.27 5 41
8 8 -0.16 327 15.03 345 1696 6.11 / 344.97 5 135
Average= 7.67
(KJ/cycle)

Cycle 63 GMT 5/ 9/2023 3:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 37 15.02 471 262 0.26 / 333.08 5 10
2 7 2005.24 40 14.71 3064 1803 2.06 / 334.89 10 25
3 13 1876.64 20 14.70 2907 855 2.92 / 335.74 5 27
4 13 1579.80 20 14.70 2526 743 3.66 / 336.48 5 32
5 13 950.00 20 14.82 1715 508 4.17 / 336.99 5 37
6 13 179.88 20 15.06 632 190 4.36 / 337.18 5 39
7 8 -0.20 327 15.04 341 1677 6.04 / 338.86 5 129
Average= 7.70
(KJ/cycle)

Cycle 62 GMT 26/ 8/2023 9: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.56 37 15.02 471 262 0.26 / 327.10 5 9
2 7 2005.16 40 14.72 3065 1805 2.07 / 328.91 9 23
3 13 1873.28 20 14.71 2895 852 2.92 / 329.76 5 26
4 13 1422.48 20 14.74 2331 687 3.61 / 330.45 5 33
5 13 958.48 20 14.82 1727 512 4.12 / 330.96 5 39
6 13 183.40 20 15.06 636 192 4.31 / 331.15 5 39
7 8 -0.16 329 15.05 338 1674 5.98 / 332.82 5 132
Average= 7.74
(KJ/cycle)

Cycle 61 GMT 16/ 8/2023 14: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 37 15.02 474 263 0.26 / 321.15 5 9
2 7 2012.52 40 14.72 3072 1809 2.07 / 322.96 9 25
3 13 1882.84 20 14.70 2916 857 2.93 / 323.82 5 30
4 13 1584.84 20 14.71 2537 746 3.68 / 324.56 5 30
5 13 806.16 20 14.87 1524 453 4.13 / 325.02 5 40
6 13 194.00 20 15.07 647 195 4.32 / 325.21 5 40
7 8 -0.08 323 15.05 335 1628 5.95 / 326.84 5 144
Average= 7.78
(KJ/cycle)

Cycle 60 GMT 6/ 8/2023 19:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 38 15.04 465 266 0.27 / 315.19 5 9
2 7 2012.28 40 14.71 3075 1809 2.08 / 317.00 9 23
3 13 1889.76 20 14.71 2922 860 2.93 / 317.86 5 28
4 13 1455.16 20 14.74 2351 693 3.63 / 318.55 5 33
5 13 989.92 20 14.82 1751 519 4.15 / 319.07 5 36
6 13 202.68 20 15.07 643 194 4.34 / 319.27 5 40
7 8 -0.16 323 15.06 333 1620 5.96 / 320.89 5 134
Average= 7.83
(KJ/cycle)

Cycle 59 GMT 28/ 7/2023 0:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 37 15.05 474 264 0.26 / 309.34 5 9
2 7 2013.48 40 14.71 3092 1819 2.08 / 311.15 16 25
3 13 1889.36 20 14.71 2921 859 2.94 / 312.01 5 27
4 13 1430.72 20 14.75 2334 689 3.63 / 312.70 5 32
5 13 833.00 20 14.88 1534 457 4.09 / 313.16 5 38
6 13 120.28 20 15.11 523 158 4.25 / 313.32 5 38
7 8 -0.16 321 15.06 333 1610 5.86 / 314.93 5 137
Average= 7.87
(KJ/cycle)

Cycle 58 GMT 18/ 7/2023 5:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 38 15.05 458 262 0.26 / 303.51 5 9
2 7 2004.08 40 14.73 3055 1800 2.06 / 305.31 9 24
3 13 1869.44 20 14.72 2898 853 2.92 / 306.16 5 28
4 13 1281.20 20 14.80 2134 632 3.55 / 306.79 5 33
5 13 843.16 20 14.88 1549 461 4.01 / 307.26 5 39
6 13 218.64 20 15.07 665 200 4.21 / 307.46 5 40
7 8 -0.16 321 15.07 334 1616 5.82 / 309.07 5 139
Average= 7.92
(KJ/cycle)

Cycle 57 GMT 8/ 7/2023 10:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 38 15.05 471 269 0.27 / 297.59 5 9
2 7 2012.36 40 14.73 3082 1816 2.09 / 299.41 9 25
3 13 1889.04 20 14.72 2923 861 2.95 / 300.27 5 25
4 13 1440.28 20 14.76 2339 690 3.64 / 300.96 5 31
5 13 839.80 20 14.89 1561 465 4.10 / 301.42 5 37
6 13 226.52 20 15.07 690 208 4.31 / 301.63 5 40
7 8 -0.12 325 15.07 330 1616 5.93 / 303.25 5 135
Average= 7.98
(KJ/cycle)

Cycle 56 GMT 28/ 6/2023 15:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 38 15.04 486 278 0.28 / 291.61 5 8
2 7 2003.88 40 14.72 3079 1813 2.09 / 293.42 8 24
3 13 1867.76 20 14.72 2891 851 2.94 / 294.27 5 26
4 13 1568.60 20 14.73 2507 739 3.68 / 295.01 5 31
5 13 939.72 20 14.86 1688 502 4.18 / 295.51 5 37
6 13 173.36 20 15.09 614 185 4.37 / 295.70 5 38
7 8 -0.12 323 15.07 334 1626 5.99 / 297.32 5 146
Average= 8.04
(KJ/cycle)

Cycle 55 GMT 18/ 6/2023 20:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 37 15.05 470 262 0.26 / 285.58 5 8
2 7 2012.12 40 14.73 3081 1815 2.08 / 287.40 8 25
3 13 1886.44 20 14.73 2924 861 2.94 / 288.26 5 28
4 13 1443.56 20 14.76 2366 698 3.64 / 288.96 5 32
5 13 845.96 20 14.89 1570 468 4.10 / 289.43 5 38
6 13 235.88 20 15.08 707 213 4.32 / 289.64 5 40
7 13 22.32 20 15.14 384 116 4.43 / 289.76 5 31
8 8 -0.16 306 15.07 341 1572 6.01 / 291.33 5 139
Average= 8.09
(KJ/cycle)

Cycle 54 GMT 9/ 6/2023 1:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.16 38 15.07 457 262 0.26 / 279.52 5 7
2 7 2013.88 40 14.73 3090 1821 2.08 / 281.34 7 24
3 13 1889.64 20 14.73 2915 859 2.94 / 282.20 5 26
4 13 1591.72 20 14.73 2535 747 3.69 / 282.95 5 31
5 13 1098.64 20 14.82 1897 562 4.25 / 283.51 5 37
6 13 171.28 20 15.10 604 182 4.43 / 283.69 5 38
7 8 -0.16 319 15.08 339 1631 6.06 / 285.32 5 146
Average= 8.15
(KJ/cycle)

Cycle 53 GMT 30/ 5/2023 6:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.16 38 15.06 464 266 0.27 / 273.61 5 8
2 7 2007.36 40 14.74 3062 1805 2.07 / 275.41 8 23
3 13 1884.36 20 14.73 2904 856 2.93 / 276.27 5 27
4 13 1595.92 20 14.74 2542 749 3.68 / 277.02 5 31
5 13 978.16 20 14.86 1735 516 4.19 / 277.53 5 38
6 13 111.56 20 15.13 504 153 4.34 / 277.69 5 38
7 13 26.24 20 15.15 381 115 4.46 / 277.80 5 30
8 8 -0.16 291 15.09 332 1458 5.92 / 279.26 5 138
Average= 8.21
(KJ/cycle)

Cycle 52 GMT 20/ 5/2023 11:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.20 38 15.07 464 266 0.27 / 267.53 5 7
2 7 2007.28 40 14.74 3087 1820 2.09 / 269.35 7 24
3 13 1888.36 20 14.73 2944 867 2.95 / 270.22 5 28
4 13 1454.52 20 14.77 2379 703 3.66 / 270.92 5 33
5 13 994.08 20 14.85 1776 527 4.18 / 271.45 5 38
6 13 362.36 20 15.04 897 270 4.45 / 271.72 5 41
7 8 -0.12 319 15.08 337 1621 6.07 / 273.34 5 147
Average= 8.28
(KJ/cycle)

Cycle 51 GMT 10/ 5/2023 16:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 38 15.09 457 262 0.26 / 261.58 5 7
2 7 2013.24 41 14.74 3061 1850 2.11 / 263.43 7 23
3 13 1870.08 20 14.73 2899 854 2.97 / 264.28 5 26
4 13 1435.04 20 14.78 2335 690 3.66 / 264.97 5 33
5 13 969.56 20 14.87 1737 517 4.17 / 265.49 5 38
6 13 183.08 20 15.11 614 186 4.36 / 265.67 5 39
7 8 -0.12 314 15.10 336 1593 5.95 / 267.27 5 140
Average= 8.35
(KJ/cycle)

Cycle 50 GMT 30/ 4/2023 21:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 38 15.09 465 267 0.27 / 255.63 5 7
2 7 2012.56 40 14.74 3069 1809 2.08 / 257.44 7 24
3 13 1885.88 20 14.73 2914 858 2.93 / 258.30 5 28
4 13 1591.32 20 14.75 2531 747 3.68 / 259.04 5 33
5 13 828.04 20 14.93 1533 458 4.14 / 259.50 5 37
6 13 213.60 20 15.11 664 201 4.34 / 259.70 5 39
7 13 21.80 20 15.17 379 115 4.45 / 259.82 5 32
8 8 -0.16 295 15.10 337 1501 5.96 / 261.32 5 145
Average= 8.43
(KJ/cycle)

Cycle 49 GMT 21/ 4/2023 2:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 37 15.09 466 260 0.26 / 249.65 5 7
2 7 2007.32 40 14.75 3074 1814 2.07 / 251.46 7 26
3 13 1877.80 20 14.75 2907 858 2.93 / 252.32 5 26
4 13 1580.56 20 14.76 2521 744 3.68 / 253.06 5 30
5 13 829.24 20 14.93 1556 465 4.14 / 253.53 5 39
6 13 227.80 20 15.11 698 211 4.35 / 253.74 5 40
7 8 -0.32 317 15.11 339 1624 5.97 / 255.36 5 131
Average= 8.51
(KJ/cycle)

Cycle 48 GMT 11/ 4/2023 7:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 37 15.09 481 269 0.27 / 243.69 5 7
2 7 2008.20 40 14.75 3063 1807 2.08 / 245.50 9 22
3 13 1879.92 20 14.75 2911 859 2.93 / 246.35 5 27
4 13 1431.52 20 14.80 2315 685 3.62 / 247.04 5 32
5 13 974.48 20 14.89 1732 516 4.14 / 247.56 5 38
6 13 328.28 20 15.08 828 250 4.39 / 247.81 5 40
7 8 -0.20 314 15.11 333 1580 5.97 / 249.39 5 132
Average= 8.60
(KJ/cycle)

Cycle 47 GMT 1/ 4/2023 12:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.00 37 15.10 470 263 0.26 / 237.75 5 7
2 7 2011.56 40 14.75 3079 1817 2.08 / 239.57 7 24
3 13 1882.48 20 14.75 2910 858 2.94 / 240.42 5 29
4 13 1431.16 20 14.81 2322 688 3.63 / 241.11 5 31
5 13 840.84 20 14.94 1543 461 4.09 / 241.57 5 39
6 13 214.72 20 15.12 661 200 4.29 / 241.77 5 40
7 8 -0.24 317 15.11 344 1648 5.93 / 243.42 5 133
Average= 8.69
(KJ/cycle)

Cycle 46 GMT 22/ 3/2023 18: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 37 15.10 470 263 0.26 / 231.95 5 7
2 7 2012.56 40 14.76 3078 1817 2.08 / 233.77 7 24
3 13 1889.40 20 14.75 2930 864 2.94 / 234.63 5 28
4 13 1306.76 20 14.84 2157 640 3.58 / 235.27 5 35
5 13 871.52 20 14.93 1587 474 4.06 / 235.75 5 39
6 13 133.44 20 15.15 556 168 4.23 / 235.92 5 40
7 8 -0.20 310 15.12 335 1570 5.80 / 237.49 5 135
Average= 8.80
(KJ/cycle)

Cycle 45 GMT 12/ 3/2023 23: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 37 15.11 460 257 0.26 / 225.93 5 7
2 7 2006.56 40 14.76 3080 1818 2.08 / 227.75 7 23
3 13 1882.32 20 14.76 2918 861 2.94 / 228.61 5 29
4 13 1592.24 20 14.77 2555 755 3.69 / 229.37 5 31
5 13 937.60 20 14.91 1685 502 4.19 / 229.87 5 37
6 13 185.08 20 15.14 640 194 4.39 / 230.06 5 40
7 8 -0.12 319 15.12 337 1625 6.01 / 231.69 5 136
Average= 8.91
(KJ/cycle)

Cycle 44 GMT 3/ 3/2023 4:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 37 15.10 456 255 0.25 / 220.06 5 7
2 7 2015.24 40 14.76 3067 1811 2.07 / 221.87 7 24
3 13 1886.44 20 14.76 2895 855 2.92 / 222.73 5 31
4 13 1429.12 20 14.82 2317 687 3.61 / 223.41 5 32
5 13 819.40 20 14.95 1526 456 4.06 / 223.87 5 40
6 13 204.16 20 15.14 648 196 4.26 / 224.07 5 42
7 13 19.44 20 15.19 361 110 4.37 / 224.18 5 29
8 8 -0.24 297 15.12 334 1500 5.87 / 225.68 5 133
Average= 9.03
(KJ/cycle)

Cycle 43 GMT 21/ 2/2023 9:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 37 15.12 456 255 0.26 / 213.98 5 7
2 7 2015.88 40 14.77 3079 1819 2.07 / 215.80 7 23
3 13 1893.76 20 14.76 2923 863 2.94 / 216.66 5 30
4 13 1596.80 20 14.77 2537 749 3.69 / 217.41 5 29
5 13 975.12 20 14.91 1737 518 4.20 / 217.93 5 36
6 13 347.56 20 15.09 877 265 4.47 / 218.20 5 41
7 8 -0.12 319 15.13 334 1612 6.08 / 219.81 5 135
Average= 9.16
(KJ/cycle)

Cycle 42 GMT 11/ 2/2023 14:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 37 15.13 453 254 0.25 / 208.21 5 7
2 7 2007.88 40 14.76 3062 1808 2.06 / 210.02 7 23
3 13 1888.76 20 14.77 2901 857 2.92 / 210.88 5 30
4 13 1439.56 20 14.82 2316 686 3.60 / 211.56 5 32
5 13 832.64 20 14.95 1537 460 4.06 / 212.02 5 38
6 13 113.84 20 15.18 510 155 4.22 / 212.18 5 38
7 8 -0.16 308 15.14 332 1548 5.77 / 213.73 5 130
Average= 9.29
(KJ/cycle)

Cycle 41 GMT 1/ 2/2023 19:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 37 15.12 462 258 0.26 / 202.39 5 8
2 7 2006.00 40 14.77 3049 1801 2.06 / 204.19 8 24
3 13 1881.80 20 14.77 2891 854 2.91 / 205.05 5 26
4 13 1590.80 20 14.78 2522 746 3.66 / 205.79 5 33
5 13 808.04 20 14.97 1505 451 4.11 / 206.24 5 39
6 13 202.16 20 15.15 646 196 4.31 / 206.44 5 40
7 8 0.00 302 15.15 332 1519 5.82 / 207.96 5 141
Average= 9.45
(KJ/cycle)

Cycle 40 GMT 23/ 1/2023 0:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 37 15.12 475 266 0.27 / 196.48 5 7
2 7 2005.52 40 14.77 3050 1802 2.07 / 198.29 7 22
3 13 1873.48 20 14.77 2894 855 2.92 / 199.14 5 27
4 13 1416.40 20 14.83 2304 683 3.61 / 199.82 5 34
5 13 813.56 20 14.97 1513 453 4.06 / 200.28 5 39
6 13 341.72 20 15.10 854 258 4.32 / 200.54 5 41
7 8 -0.20 317 15.14 333 1598 5.92 / 202.13 5 133
Average= 9.63
(KJ/cycle)

Cycle 39 GMT 13/ 1/2023 5:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.08 37 15.12 461 258 0.26 / 190.51 5 7
2 10 1004.32 3 15.09 1789 81 0.34 / 190.59 5 22
3 3 935.72 -1 15.48 2 0 0.08 / 190.59 5 22
4 7 2008.56 40 14.78 3066 1813 2.15 / 192.40 22 25
5 13 1891.52 20 14.78 2923 864 3.02 / 193.26 5 25
6 13 1309.76 20 14.86 2164 643 3.66 / 193.91 5 34
7 13 858.12 20 14.95 1586 474 4.13 / 194.38 5 40
8 13 250.56 20 15.14 718 217 4.35 / 194.60 5 41
9 8 -0.08 310 15.14 345 1619 5.97 / 196.22 5 134
Average= 9.81
(KJ/cycle)

Cycle 38 GMT 3/ 1/2023 10:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 37 15.14 462 259 0.26 / 184.57 5 7
2 7 2006.64 40 14.77 3074 1816 2.07 / 186.39 7 24
3 13 1883.12 20 14.77 2904 858 2.93 / 187.24 5 29
4 13 1443.16 20 14.83 2365 701 3.63 / 187.95 5 31
5 13 846.36 20 14.96 1570 470 4.10 / 188.42 5 38
6 13 228.08 20 15.14 699 212 4.32 / 188.63 5 39
7 8 -0.20 317 15.14 338 1622 5.94 / 190.25 5 137
Average= 10.01
(KJ/cycle)

Cycle 37 GMT 24/12/2022 15:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 37 15.14 467 262 0.26 / 179.31 5 8
2 7 2008.56 40 14.77 3080 1820 2.08 / 181.13 8 23
3 13 1561.36 20 14.84 2518 747 2.83 / 181.88 5 28
4 13 980.72 20 14.95 1763 527 3.36 / 182.40 5 36
5 13 381.60 20 15.11 933 282 3.64 / 182.69 5 40
6 8 -0.08 319 15.16 336 1625 5.26 / 184.31 5 144
Average= 10.24
(KJ/cycle)

Cycle 36 GMT 14/12/2022 19:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 37 15.14 477 267 0.27 / 174.21 5 8
2 7 2005.32 40 14.78 3064 1811 2.08 / 176.02 8 25
3 13 1369.88 20 14.88 2241 667 2.75 / 176.69 5 32
4 13 944.28 20 14.96 1700 509 3.25 / 177.20 5 39
5 13 241.00 20 15.16 711 216 3.47 / 177.41 5 39
6 8 -0.16 323 15.16 334 1635 5.11 / 179.05 5 135
Average= 10.53
(KJ/cycle)

Cycle 35 GMT 4/12/2022 23:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 37 15.15 469 263 0.26 / 168.98 5 8
2 7 2008.56 40 14.78 3080 1821 2.08 / 170.80 8 23
3 13 1571.04 20 14.85 2519 748 2.83 / 171.55 5 30
4 13 974.76 20 14.95 1745 522 3.35 / 172.07 5 37
5 13 275.60 20 15.15 773 234 3.59 / 172.31 5 38
6 8 0.00 321 15.17 336 1636 5.22 / 173.94 5 149
Average= 10.87
(KJ/cycle)

Cycle 34 GMT 25/11/2022 3:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 37 15.15 467 262 0.26 / 163.79 5 8
2 7 2007.12 40 14.78 3067 1813 2.07 / 165.60 8 27
3 13 1568.92 20 14.85 2496 741 2.82 / 166.34 5 28
4 13 991.56 20 14.96 1752 524 3.34 / 166.87 5 34
5 13 302.28 20 15.15 793 240 3.58 / 167.11 5 38
6 8 0.04 321 15.17 331 1612 5.19 / 168.72 5 145
Average= 11.25
(KJ/cycle)

Cycle 33 GMT 15/11/2022 7:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 37 15.15 468 262 0.26 / 158.67 5 9
2 7 2005.72 40 14.79 3049 1804 2.07 / 160.47 9 26
3 13 1535.72 20 14.86 2463 732 2.80 / 161.20 5 31
4 13 961.24 20 14.97 1714 513 3.31 / 161.72 5 35
5 13 279.20 20 15.16 754 229 3.54 / 161.94 5 38
6 8 0.04 314 15.18 332 1582 5.12 / 163.53 5 129
Average= 11.68
(KJ/cycle)

Cycle 32 GMT 5/11/2022 11:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.44 37 15.15 469 263 0.26 / 153.48 5 9
2 7 2004.48 41 14.79 3069 1861 2.12 / 155.34 9 25
3 13 1434.36 20 14.89 2354 701 2.82 / 156.04 5 31
4 13 874.24 20 14.99 1611 483 3.31 / 156.52 5 37
5 13 276.04 20 15.16 768 233 3.54 / 156.75 5 38
6 8 0.00 323 15.17 337 1651 5.19 / 158.40 5 137
Average= 12.18
(KJ/cycle)

Cycle 31 GMT 26/10/2022 15:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.48 37 15.15 481 270 0.27 / 148.25 5 9
2 7 2008.64 40 14.79 3064 1813 2.08 / 150.06 12 25
3 13 1562.32 20 14.86 2498 742 2.82 / 150.80 5 29
4 13 981.40 20 14.97 1731 518 3.34 / 151.32 5 37
5 13 283.28 20 15.17 764 232 3.57 / 151.55 5 38
6 8 -0.08 327 15.18 334 1658 5.23 / 153.21 5 131
Average= 12.77
(KJ/cycle)

Cycle 30 GMT 16/10/2022 19:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 37 15.16 477 268 0.27 / 143.00 5 9
2 7 2004.28 40 14.80 3068 1816 2.08 / 144.82 9 24
3 13 1573.24 20 14.87 2526 751 2.84 / 145.57 5 33
4 13 990.40 20 14.97 1754 525 3.36 / 146.09 5 36
5 13 321.52 20 15.16 820 249 3.61 / 146.34 5 38
6 8 -0.04 323 15.18 334 1638 5.25 / 147.98 5 136
Average= 13.45
(KJ/cycle)

Cycle 29 GMT 6/10/2022 23:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 37 15.16 484 271 0.27 / 137.75 5 9
2 7 2015.96 41 14.80 3069 1862 2.13 / 139.61 9 23
3 13 1563.00 20 14.87 2495 742 2.88 / 140.35 5 30
4 13 961.12 20 14.98 1724 517 3.39 / 140.87 5 38
5 13 255.44 20 15.18 725 220 3.61 / 141.09 5 38
6 8 0.04 321 15.18 337 1642 5.25 / 142.73 5 130
Average= 14.27
(KJ/cycle)

Cycle 28 GMT 27/ 9/2022 3:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.48 37 15.16 482 270 0.27 / 132.53 5 9
2 7 2022.28 40 14.81 3076 1822 2.09 / 134.35 9 24
3 13 1566.96 20 14.87 2504 745 2.84 / 135.09 5 31
4 13 882.56 20 15.01 1621 487 3.32 / 135.58 5 36
5 13 316.84 20 15.16 814 247 3.57 / 135.83 5 39
6 8 0.00 319 15.19 341 1652 5.22 / 137.48 5 138
Average= 15.28
(KJ/cycle)

Cycle 27 GMT 17/ 9/2022 7:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.48 37 15.17 466 262 0.26 / 127.26 5 9
2 7 2014.68 40 14.81 3077 1823 2.08 / 129.09 9 24
3 13 1586.40 20 14.88 2517 749 2.83 / 129.84 5 30
4 13 994.48 20 14.98 1755 526 3.36 / 130.36 5 36
5 13 295.80 20 15.17 783 238 3.60 / 130.60 5 39
6 8 0.08 319 15.19 342 1657 5.25 / 132.26 5 130
Average= 16.53
(KJ/cycle)

Cycle 26 GMT 7/ 9/2022 11:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 37 15.17 463 260 0.26 / 122.06 5 9
2 7 2016.12 40 14.81 3080 1825 2.08 / 123.89 9 24
3 13 1450.00 20 14.91 2366 706 2.79 / 124.59 5 31
4 13 990.52 20 14.98 1744 523 3.31 / 125.12 5 36
5 13 293.92 20 15.17 797 242 3.55 / 125.36 5 39
6 8 -0.04 323 15.19 335 1644 5.20 / 127.00 5 140
Average= 18.14
(KJ/cycle)

Cycle 25 GMT 28/ 8/2022 15:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 36 15.17 491 268 0.27 / 116.85 5 8
2 7 2021.24 40 14.81 3090 1831 2.10 / 118.68 8 25
3 13 1469.56 20 14.90 2390 712 2.81 / 119.39 5 30
4 13 1007.84 20 14.98 1782 534 3.34 / 119.93 5 36
5 13 295.64 20 15.18 786 239 3.58 / 120.17 5 38
6 8 0.00 321 15.19 336 1638 5.22 / 121.80 5 129
Average= 20.30
(KJ/cycle)

Cycle 24 GMT 18/ 8/2022 19:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 36 15.17 482 263 0.26 / 111.71 5 8
2 7 2005.36 40 14.81 3056 1810 2.07 / 113.52 8 25
3 13 1359.48 20 14.93 2249 672 2.75 / 114.19 5 33
4 13 934.76 20 15.00 1683 505 3.25 / 114.69 5 38
5 13 233.76 20 15.20 695 211 3.46 / 114.90 5 39
6 8 -0.04 323 15.19 342 1678 5.14 / 116.58 5 141
Average= 23.32
(KJ/cycle)

Cycle 23 GMT 8/ 8/2022 23:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.88 36 15.17 480 262 0.26 / 106.53 5 8
2 3 1022.68 1 15.20 1803 27 0.29 / 106.55 5 13
3 7 2005.64 40 14.82 3065 1817 2.11 / 108.37 13 25
4 13 1457.12 20 14.91 2376 709 2.81 / 109.08 5 32
5 13 900.08 20 15.01 1628 489 3.30 / 109.57 5 37
6 13 224.20 20 15.21 676 206 3.51 / 109.77 5 38
7 8 -0.08 323 15.20 340 1669 5.18 / 111.44 5 133
Average= 27.86
(KJ/cycle)

Cycle 22 GMT 30/ 7/2022 3:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 36 15.17 469 256 0.26 / 101.25 5 8
2 7 2005.64 40 14.83 3064 1818 2.07 / 103.07 8 23
3 13 1580.04 20 14.89 2520 750 2.82 / 103.82 5 32
4 13 897.20 20 15.02 1636 491 3.32 / 104.31 5 39
5 13 308.72 20 15.18 812 247 3.56 / 104.56 5 39
6 8 -0.04 325 15.20 345 1704 5.27 / 106.26 5 130
Average= 35.42
(KJ/cycle)

Cycle 21 GMT 20/ 7/2022 7:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.64 36 15.18 476 260 0.26 / 95.91 5 8
2 7 2005.80 40 14.83 3067 1819 2.08 / 97.73 8 23
3 13 1554.64 20 14.91 2486 741 2.82 / 98.47 5 30
4 13 974.44 20 15.01 1729 519 3.34 / 98.99 5 35
5 13 370.88 20 15.16 902 273 3.61 / 99.26 5 41
6 8 -0.08 340 15.20 336 1736 5.35 / 101.00 5 142
Average= 50.50
(KJ/cycle)

Cycle 20 GMT 10/ 7/2022 11:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 36 15.18 469 256 0.26 / 90.70 5 8
2 7 2010.80 40 14.84 3073 1824 2.08 / 92.53 8 26
3 13 1477.72 20 14.92 2395 715 2.80 / 93.24 5 32
4 13 922.08 20 15.01 1664 500 3.29 / 93.74 5 36
5 13 332.16 20 15.17 844 256 3.55 / 94.00 5 40
6 8 0.00 329 15.20 330 1650 5.20 / 95.65 5 137
Average= 95.65
(KJ/cycle)

Cycle 18 GMT 20/ 6/2022 19:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 36 15.19 475 260 0.26 / 85.44 5 8
2 7 2005.84 40 14.84 3063 1818 2.08 / 87.26 8 24
3 13 1545.12 20 14.92 2471 737 2.82 / 88.00 5 31
4 13 1030.84 20 15.00 1809 543 3.36 / 88.54 5 36
5 13 291.96 20 15.20 778 237 3.59 / 88.78 5 40
6 8 0.04 329 15.21 334 1671 5.27 / 90.45 5 155
Average= 4.76
(KJ/cycle)

Cycle 17 GMT 10/ 6/2022 23:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.56 36 15.19 484 265 0.26 / 80.31 5 7
2 7 2009.40 41 14.84 3072 1869 2.13 / 82.18 7 23
3 13 1460.04 20 14.94 2372 709 2.84 / 82.89 5 32
4 13 885.88 20 15.03 1622 488 3.33 / 83.37 5 37
5 13 192.60 20 15.23 644 196 3.53 / 83.57 5 37
6 8 0.00 314 15.22 337 1611 5.14 / 85.18 5 129
Average= 4.73
(KJ/cycle)

Cycle 16 GMT 1/ 6/2022 3:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 36 15.21 468 256 0.26 / 75.21 5 7
2 7 2004.56 40 14.85 3064 1820 2.08 / 77.03 7 23
3 13 1444.60 20 14.95 2355 704 2.78 / 77.74 5 31
4 13 898.48 20 15.03 1647 495 3.28 / 78.23 5 37
5 13 205.12 20 15.23 664 202 3.48 / 78.43 5 37
6 8 -0.04 317 15.22 334 1611 5.09 / 80.04 5 132
Average= 4.71
(KJ/cycle)

Cycle 15 GMT 22/ 5/2022 7:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 36 15.20 462 253 0.25 / 70.16 5 7
2 7 2005.84 40 14.85 3060 1818 2.07 / 71.98 7 25
3 13 1463.88 20 14.94 2389 714 2.78 / 72.69 5 30
4 13 888.04 20 15.04 1633 491 3.28 / 73.18 5 37
5 13 202.56 20 15.24 647 197 3.47 / 73.38 5 37
6 8 0.00 310 15.23 334 1577 5.05 / 74.96 5 132
Average= 4.68
(KJ/cycle)

Cycle 14 GMT 12/ 5/2022 11:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.72 36 15.21 473 259 0.26 / 64.99 5 7
2 7 2005.96 40 14.85 3076 1827 2.09 / 66.82 7 26
3 13 1460.96 20 14.95 2378 711 2.80 / 67.53 5 30
4 13 893.76 20 15.04 1631 491 3.29 / 68.02 5 38
5 13 310.52 20 15.20 815 248 3.54 / 68.27 5 39
6 8 -0.16 319 15.23 337 1637 5.17 / 69.91 5 138
Average= 4.66
(KJ/cycle)

Cycle 13 GMT 2/ 5/2022 15:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 36 15.21 470 257 0.26 / 59.81 5 7
2 7 2010.16 40 14.86 3061 1819 2.08 / 61.63 7 23
3 13 1477.04 20 14.94 2394 715 2.79 / 62.34 5 31
4 13 1018.16 20 15.01 1800 540 3.33 / 62.88 5 36
5 13 392.16 20 15.17 937 284 3.62 / 63.17 5 41
6 8 -0.12 310 15.23 332 1567 5.18 / 64.73 5 134
Average= 4.62
(KJ/cycle)

Cycle 12 GMT 22/ 4/2022 19:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 36 15.21 473 259 0.26 / 54.63 5 7
2 7 2004.44 40 14.87 3048 1813 2.07 / 56.44 7 25
3 13 1546.08 20 14.95 2482 742 2.81 / 57.19 5 31
4 13 1057.32 20 15.01 1848 555 3.37 / 57.74 5 36
5 13 234.84 20 15.24 691 211 3.58 / 57.95 5 37
6 8 -0.12 312 15.24 336 1598 5.18 / 59.55 5 135
Average= 4.58
(KJ/cycle)

Cycle 11 GMT 12/ 4/2022 23:47: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 38 15.21 465 269 0.27 / 49.40 5 6
2 3 954.92 -1 15.56 3 0 0.00 / 49.40 5 6
3 7 2006.48 40 14.87 3065 1823 2.09 / 51.22 6 24
4 13 1561.88 20 14.94 2498 746 2.84 / 51.97 5 30
5 13 985.80 20 15.03 1760 529 3.37 / 52.50 5 37
6 13 283.96 20 15.22 766 233 3.60 / 52.73 5 38
7 13 25.64 20 15.29 377 115 3.72 / 52.85 5 31
8 8 -0.12 289 15.23 346 1523 5.24 / 54.37 5 136
Average= 4.53
(KJ/cycle)

Cycle 10 GMT 3/ 4/2022 3:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 36 15.23 457 251 0.25 / 44.23 5 7
2 10 1022.28 4 15.17 1813 110 0.36 / 44.34 5 22
3 7 2012.44 40 14.87 3068 1825 2.19 / 46.17 22 23
4 13 1452.04 20 14.97 2346 702 2.89 / 46.87 5 31
5 13 889.64 20 15.06 1616 487 3.37 / 47.36 5 39
6 13 211.28 20 15.24 668 204 3.58 / 47.56 5 37
7 8 -0.08 308 15.24 335 1572 5.15 / 49.13 5 133
Average= 4.47
(KJ/cycle)

Cycle 9 GMT 24/ 3/2022 7:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 36 15.22 473 259 0.26 / 39.08 5 7
2 7 2007.04 40 14.87 3072 1827 2.09 / 40.91 7 24
3 13 1539.64 20 14.95 2471 739 2.83 / 41.65 5 30
4 13 973.80 20 15.04 1746 525 3.35 / 42.17 5 36
5 13 275.88 20 15.22 776 236 3.59 / 42.41 5 38
6 8 0.00 308 15.24 335 1572 5.16 / 43.98 5 135
Average= 4.40
(KJ/cycle)

Cycle 8 GMT 14/ 3/2022 11:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 36 15.23 458 251 0.25 / 33.92 5 6
2 7 2005.92 40 14.88 3053 1817 2.07 / 35.74 6 25
3 13 1557.64 20 14.95 2493 745 2.81 / 36.48 5 32
4 13 1061.20 20 15.02 1852 556 3.37 / 37.04 5 36
5 13 232.04 20 15.25 686 209 3.58 / 37.25 5 37
6 13 19.60 20 15.30 363 111 3.69 / 37.36 5 30
7 8 -0.24 289 15.24 332 1462 5.15 / 38.82 5 133
Average= 4.31
(KJ/cycle)

Cycle 7 GMT 4/ 3/2022 15:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 36 15.22 472 259 0.26 / 28.82 5 7
2 7 2015.48 40 14.89 3068 1827 2.09 / 30.65 8 25
3 13 1540.72 20 14.96 2474 740 2.83 / 31.39 5 31
4 13 946.80 20 15.05 1707 514 3.34 / 31.90 5 36
5 13 243.72 20 15.24 704 215 3.55 / 32.12 5 37
6 13 24.12 20 15.30 365 112 3.67 / 32.23 5 30
7 8 -0.04 285 15.24 332 1442 5.11 / 33.67 5 129
Average= 4.21
(KJ/cycle)

Cycle 6 GMT 22/ 2/2022 19:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 35 15.22 458 244 0.24 / 23.65 5 6
2 3 1048.92 1 15.22 1842 28 0.27 / 23.68 5 27
3 7 2005.56 40 14.89 3053 1818 2.09 / 25.49 27 24
4 13 1477.64 20 14.98 2374 711 2.80 / 26.21 5 30
5 13 914.64 20 15.06 1658 499 3.30 / 26.70 5 38
6 13 330.00 20 15.21 842 256 3.56 / 26.96 5 38
7 13 15.64 20 15.31 354 108 3.67 / 27.07 5 29
8 8 0.00 289 15.24 339 1493 5.16 / 28.56 5 154
Average= 4.08
(KJ/cycle)

Cycle 5 GMT 12/ 2/2022 23:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 31 15.24 459 217 0.22 / 18.37 5 7
2 10 1013.48 3 15.18 1796 82 0.30 / 18.45 5 20
3 3 1043.44 1 15.23 1840 28 0.33 / 18.48 5 24
4 7 2007.32 40 14.90 3051 1818 2.15 / 20.30 24 25
5 13 1555.84 20 14.96 2491 745 2.89 / 21.04 5 30
6 13 866.08 20 15.07 1588 479 3.37 / 21.52 5 38
7 13 381.60 20 15.19 914 278 3.65 / 21.80 5 40
8 13 18.84 20 15.30 364 111 3.76 / 21.91 5 29
9 8 0.00 293 15.23 335 1495 5.25 / 23.40 5 132
Average= 3.90
(KJ/cycle)

Cycle 4 GMT 3/ 2/2022 3:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 35 15.23 467 249 0.25 / 13.83 5 7
2 7 1513.12 40 15.05 2421 1457 1.71 / 15.28 7 28
3 13 1425.16 20 15.04 2304 693 2.40 / 15.98 5 30
4 13 827.04 20 15.12 1532 463 2.86 / 16.44 5 38
5 13 114.16 20 15.30 511 156 3.02 / 16.60 5 33
6 8 0.00 304 15.26 335 1554 4.57 / 18.15 5 134
Average= 3.63
(KJ/cycle)

Cycle 3 GMT 1/ 2/2022 18:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 35 15.23 459 245 0.24 / 9.38 5 6
2 7 1507.56 40 15.05 2413 1453 1.70 / 10.83 9 29
3 13 1224.16 20 15.07 2052 618 2.32 / 11.45 5 31
4 13 772.96 20 15.12 1460 442 2.76 / 11.89 5 38
5 13 82.40 20 15.31 476 146 2.90 / 12.04 5 31
6 8 -0.04 300 15.26 336 1538 4.44 / 13.58 5 157
Average= 3.39
(KJ/cycle)

Cycle 2 GMT 31/ 1/2022 8:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 31 15.29 446 211 0.21 / 4.82 5 6
2 10 1018.28 5 15.22 1731 132 0.34 / 4.95 5 18
3 7 1508.16 40 15.05 2403 1447 1.79 / 6.40 18 27
4 13 1410.76 20 15.05 2295 691 2.48 / 7.09 5 30
5 13 719.88 20 15.14 1382 418 2.90 / 7.51 5 37
6 13 134.80 20 15.29 541 165 3.06 / 7.68 5 33
7 8 -0.08 297 15.27 322 1460 4.52 / 9.14 5 137
Average= 3.05
(KJ/cycle)

Cycle 1 GMT 29/ 1/2022 23:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 31 15.47 414 199 0.20 / 1.84 5 6
2 10 1011.08 4 15.27 1740 106 0.30 / 1.95 5 15
3 7 1006.40 41 15.17 1753 1090 1.40 / 3.04 15 32
4 13 56.28 20 15.39 416 128 1.52 / 3.16 5 34
5 8 0.00 295 15.33 320 1447 2.97 / 4.61 5 139
Average= 2.31
(KJ/cycle)

Cycle 0 GMT 29/ 1/2022 12:56: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 81.76 30 15.62 387 181 0.18 / 0.18 5 7
2 7 96.28 40 15.60 394 246 0.43 / 0.43 7 7
3 13 59.60 20 15.59 342 107 0.53 / 0.53 5 10
4 8 0.28 276 15.55 258 1107 1.64 / 1.64 5 144
Average= 1.64
(KJ/cycle)