SIO Argo Site:
|
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.40 | 35 | 14.94 | 525 | 275 | 0.27 / 466.20 | 6 | 8 |
2 | 7 | 2004.96 | 40 | 14.63 | 3184 | 1863 | 2.14 / 468.07 | 8 | 61 |
3 | 13 | 1912.72 | 20 | 14.59 | 3067 | 895 | 3.03 / 468.96 | 6 | 65 |
4 | 13 | 1271.64 | 20 | 14.65 | 2239 | 656 | 3.69 / 469.62 | 6 | 78 |
5 | 13 | 738.76 | 20 | 14.77 | 1505 | 445 | 4.13 / 470.06 | 6 | 80 |
6 | 13 | 42.56 | 20 | 14.99 | 516 | 155 | 4.29 / 470.22 | 6 | 77 |
7 | 13 | 16.52 | 20 | 14.99 | 477 | 143 | 4.43 / 470.36 | 6 | 78 |
8 | 8 | -0.08 | 210 | 14.92 | 427 | 1338 | 5.77 / 471.70 | 6 | 144 |
Average= | 6.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 35 | 14.93 | 514 | 269 | 0.27 / 460.41 | 6 | 13 |
2 | 7 | 2007.08 | 40 | 14.62 | 3168 | 1853 | 2.12 / 462.26 | 13 | 59 |
3 | 13 | 1919.00 | 20 | 14.59 | 3083 | 900 | 3.02 / 463.16 | 6 | 65 |
4 | 13 | 1360.80 | 20 | 14.63 | 2359 | 690 | 3.71 / 463.85 | 6 | 73 |
5 | 13 | 695.32 | 20 | 14.78 | 1445 | 427 | 4.14 / 464.28 | 6 | 84 |
6 | 13 | 61.12 | 20 | 14.98 | 552 | 165 | 4.30 / 464.45 | 6 | 74 |
7 | 13 | 21.92 | 20 | 14.99 | 479 | 144 | 4.45 / 464.59 | 6 | 67 |
8 | 8 | -0.04 | 210 | 14.92 | 427 | 1338 | 5.79 / 465.93 | 6 | 134 |
Average= | 6.85 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.56 | 35 | 14.93 | 519 | 271 | 0.27 / 454.68 | 6 | 13 |
2 | 7 | 2003.88 | 40 | 14.62 | 3190 | 1866 | 2.14 / 456.55 | 13 | 61 |
3 | 13 | 1817.80 | 20 | 14.61 | 2963 | 866 | 3.00 / 457.41 | 6 | 67 |
4 | 13 | 1287.60 | 20 | 14.65 | 2256 | 661 | 3.66 / 458.07 | 6 | 76 |
5 | 13 | 759.64 | 20 | 14.75 | 1531 | 452 | 4.12 / 458.52 | 6 | 81 |
6 | 13 | 51.32 | 20 | 14.98 | 532 | 159 | 4.27 / 458.68 | 6 | 74 |
7 | 13 | 29.00 | 20 | 14.97 | 492 | 147 | 4.42 / 458.83 | 6 | 73 |
8 | 8 | -0.16 | 208 | 14.91 | 423 | 1312 | 5.73 / 460.14 | 6 | 136 |
Average= | 6.87 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.68 | 35 | 14.93 | 514 | 269 | 0.27 / 448.80 | 6 | 10 |
2 | 7 | 2010.16 | 40 | 14.63 | 3184 | 1863 | 2.13 / 450.66 | 10 | 60 |
3 | 13 | 1923.48 | 20 | 14.61 | 3080 | 900 | 3.03 / 451.56 | 6 | 63 |
4 | 13 | 1483.52 | 20 | 14.61 | 2512 | 734 | 3.77 / 452.30 | 6 | 70 |
5 | 13 | 806.32 | 20 | 14.74 | 1602 | 472 | 4.24 / 452.77 | 6 | 82 |
6 | 13 | 61.68 | 20 | 14.98 | 541 | 162 | 4.40 / 452.93 | 6 | 71 |
7 | 13 | 16.96 | 20 | 14.98 | 467 | 140 | 4.54 / 453.07 | 6 | 68 |
8 | 8 | -0.04 | 212 | 14.92 | 423 | 1338 | 5.88 / 454.41 | 6 | 146 |
Average= | 6.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.40 | 35 | 14.92 | 516 | 269 | 0.27 / 443.00 | 6 | 13 |
2 | 7 | 2004.20 | 40 | 14.62 | 3212 | 1878 | 2.15 / 444.87 | 13 | 60 |
3 | 13 | 1805.76 | 20 | 14.61 | 2947 | 861 | 3.01 / 445.74 | 6 | 64 |
4 | 13 | 1493.08 | 20 | 14.61 | 2527 | 738 | 3.75 / 446.47 | 6 | 72 |
5 | 13 | 624.48 | 20 | 14.79 | 1367 | 404 | 4.15 / 446.88 | 6 | 82 |
6 | 13 | 81.64 | 20 | 14.97 | 577 | 173 | 4.32 / 447.05 | 6 | 78 |
7 | 13 | 22.36 | 20 | 14.98 | 479 | 144 | 4.47 / 447.19 | 6 | 74 |
8 | 8 | -0.08 | 210 | 14.91 | 427 | 1337 | 5.80 / 448.53 | 6 | 136 |
Average= | 6.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.40 | 35 | 14.93 | 511 | 267 | 0.27 / 437.27 | 6 | 11 |
2 | 7 | 2013.76 | 40 | 14.63 | 3200 | 1873 | 2.14 / 439.14 | 11 | 60 |
3 | 13 | 1918.24 | 20 | 14.60 | 3077 | 898 | 3.04 / 440.04 | 6 | 66 |
4 | 13 | 1258.76 | 20 | 14.67 | 2195 | 644 | 3.68 / 440.68 | 6 | 75 |
5 | 13 | 711.60 | 20 | 14.77 | 1462 | 432 | 4.11 / 441.11 | 6 | 80 |
6 | 13 | 41.00 | 20 | 14.99 | 505 | 151 | 4.27 / 441.26 | 6 | 75 |
7 | 13 | 16.96 | 20 | 14.98 | 466 | 140 | 4.41 / 441.40 | 6 | 71 |
8 | 8 | -0.08 | 210 | 14.92 | 422 | 1322 | 5.73 / 442.73 | 6 | 136 |
Average= | 6.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.00 | 35 | 14.91 | 522 | 272 | 0.27 / 431.51 | 6 | 14 |
2 | 7 | 2008.36 | 40 | 14.62 | 3187 | 1864 | 2.14 / 433.37 | 14 | 59 |
3 | 13 | 1925.04 | 20 | 14.60 | 3085 | 901 | 3.04 / 434.27 | 6 | 65 |
4 | 13 | 1360.28 | 20 | 14.64 | 2332 | 683 | 3.72 / 434.96 | 6 | 72 |
5 | 13 | 702.56 | 20 | 14.78 | 1438 | 425 | 4.14 / 435.38 | 6 | 80 |
6 | 13 | 46.76 | 20 | 14.99 | 516 | 155 | 4.30 / 435.54 | 6 | 72 |
7 | 13 | 27.88 | 20 | 14.98 | 479 | 144 | 4.44 / 435.68 | 6 | 69 |
8 | 8 | 0.00 | 212 | 14.92 | 417 | 1319 | 5.76 / 437.00 | 6 | 131 |
Average= | 6.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.52 | 35 | 14.92 | 538 | 281 | 0.28 / 425.89 | 6 | 15 |
2 | 7 | 2004.24 | 40 | 14.63 | 3178 | 1860 | 2.14 / 427.75 | 15 | 60 |
3 | 13 | 1808.16 | 20 | 14.63 | 2930 | 857 | 3.00 / 428.61 | 6 | 64 |
4 | 13 | 1171.20 | 20 | 14.69 | 2077 | 610 | 3.61 / 429.22 | 6 | 75 |
5 | 13 | 640.64 | 20 | 14.79 | 1369 | 405 | 4.01 / 429.63 | 6 | 83 |
6 | 13 | 30.72 | 20 | 14.99 | 489 | 147 | 4.16 / 429.77 | 6 | 74 |
7 | 13 | 14.76 | 20 | 14.98 | 458 | 137 | 4.30 / 429.91 | 6 | 71 |
8 | 8 | 0.20 | 212 | 14.91 | 420 | 1328 | 5.62 / 431.24 | 6 | 137 |
Average= | 6.96 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.12 | 35 | 14.92 | 517 | 270 | 0.27 / 420.04 | 6 | 14 |
2 | 7 | 2012.24 | 40 | 14.64 | 3161 | 1851 | 2.12 / 421.89 | 14 | 56 |
3 | 13 | 1922.92 | 20 | 14.60 | 3089 | 902 | 3.02 / 422.79 | 6 | 65 |
4 | 13 | 1489.32 | 20 | 14.62 | 2492 | 729 | 3.75 / 423.52 | 6 | 72 |
5 | 13 | 812.28 | 20 | 14.74 | 1599 | 471 | 4.22 / 423.99 | 6 | 83 |
6 | 13 | 34.28 | 20 | 14.99 | 494 | 148 | 4.37 / 424.14 | 6 | 74 |
7 | 13 | 12.12 | 20 | 14.98 | 461 | 138 | 4.51 / 424.28 | 6 | 70 |
8 | 8 | -0.12 | 212 | 14.91 | 423 | 1337 | 5.85 / 425.61 | 6 | 140 |
Average= | 6.98 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.92 | 35 | 14.92 | 524 | 274 | 0.27 / 414.34 | 6 | 13 |
2 | 7 | 2011.68 | 40 | 14.64 | 3156 | 1848 | 2.12 / 416.19 | 13 | 58 |
3 | 13 | 1912.96 | 20 | 14.62 | 3045 | 890 | 3.01 / 417.08 | 6 | 64 |
4 | 13 | 1177.24 | 20 | 14.69 | 2100 | 617 | 3.63 / 417.70 | 6 | 74 |
5 | 13 | 755.56 | 20 | 14.76 | 1519 | 448 | 4.08 / 418.15 | 6 | 81 |
6 | 13 | 45.52 | 20 | 14.98 | 515 | 154 | 4.23 / 418.30 | 6 | 76 |
7 | 13 | 18.08 | 20 | 14.98 | 468 | 140 | 4.37 / 418.44 | 6 | 75 |
8 | 8 | -0.08 | 212 | 14.91 | 419 | 1324 | 5.70 / 419.77 | 6 | 140 |
Average= | 7.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.64 | 35 | 14.91 | 540 | 282 | 0.28 / 408.61 | 6 | 17 |
2 | 7 | 2005.00 | 40 | 14.64 | 3182 | 1863 | 2.15 / 410.47 | 17 | 61 |
3 | 13 | 1912.76 | 20 | 14.62 | 3058 | 894 | 3.04 / 411.37 | 6 | 64 |
4 | 13 | 1272.36 | 20 | 14.66 | 2223 | 652 | 3.69 / 412.02 | 6 | 75 |
5 | 13 | 730.48 | 20 | 14.76 | 1492 | 440 | 4.13 / 412.46 | 6 | 81 |
6 | 13 | 21.92 | 20 | 14.99 | 477 | 143 | 4.27 / 412.60 | 6 | 73 |
7 | 8 | 0.76 | 231 | 14.91 | 426 | 1467 | 5.74 / 414.07 | 6 | 136 |
Average= | 7.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.72 | 35 | 14.91 | 546 | 285 | 0.28 / 402.82 | 6 | 16 |
2 | 7 | 2006.60 | 40 | 14.62 | 3198 | 1870 | 2.16 / 404.69 | 16 | 60 |
3 | 13 | 1909.44 | 20 | 14.62 | 3075 | 899 | 3.05 / 405.59 | 6 | 66 |
4 | 13 | 1266.12 | 20 | 14.66 | 2219 | 651 | 3.70 / 406.24 | 6 | 75 |
5 | 13 | 727.48 | 20 | 14.76 | 1491 | 440 | 4.15 / 406.68 | 6 | 85 |
6 | 13 | 34.96 | 20 | 14.98 | 500 | 150 | 4.29 / 406.83 | 6 | 75 |
7 | 13 | 10.68 | 20 | 14.98 | 460 | 138 | 4.43 / 406.97 | 6 | 72 |
8 | 8 | -0.16 | 212 | 14.90 | 430 | 1358 | 5.79 / 408.33 | 6 | 139 |
Average= | 7.04 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.36 | 35 | 14.90 | 525 | 274 | 0.27 / 397.05 | 6 | 16 |
2 | 7 | 2006.60 | 40 | 14.64 | 3200 | 1874 | 2.15 / 398.92 | 16 | 61 |
3 | 13 | 1911.92 | 20 | 14.61 | 3064 | 895 | 3.04 / 399.82 | 6 | 65 |
4 | 13 | 1272.92 | 20 | 14.67 | 2219 | 651 | 3.69 / 400.47 | 6 | 74 |
5 | 13 | 736.40 | 20 | 14.76 | 1503 | 444 | 4.14 / 400.91 | 6 | 81 |
6 | 13 | 39.36 | 20 | 14.98 | 508 | 152 | 4.29 / 401.07 | 6 | 77 |
7 | 13 | 14.80 | 20 | 14.98 | 469 | 141 | 4.43 / 401.21 | 6 | 70 |
8 | 8 | -0.12 | 210 | 14.90 | 425 | 1330 | 5.76 / 402.54 | 6 | 138 |
Average= | 7.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.20 | 35 | 14.91 | 530 | 277 | 0.28 / 391.33 | 6 | 16 |
2 | 7 | 2004.68 | 40 | 14.64 | 3188 | 1867 | 2.14 / 393.19 | 38 | 60 |
3 | 13 | 1911.40 | 20 | 14.62 | 3049 | 892 | 3.04 / 394.09 | 6 | 63 |
4 | 13 | 1172.52 | 20 | 14.68 | 2079 | 610 | 3.65 / 394.70 | 6 | 77 |
5 | 13 | 738.36 | 20 | 14.76 | 1495 | 441 | 4.09 / 395.14 | 6 | 81 |
6 | 13 | 45.12 | 20 | 14.98 | 518 | 155 | 4.24 / 395.29 | 6 | 73 |
7 | 13 | 14.88 | 20 | 14.98 | 462 | 138 | 4.38 / 395.43 | 6 | 71 |
8 | 8 | -0.04 | 212 | 14.90 | 426 | 1346 | 5.73 / 396.78 | 6 | 130 |
Average= | 7.09 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.96 | 35 | 14.91 | 525 | 274 | 0.27 / 385.55 | 6 | 13 |
2 | 7 | 2006.44 | 41 | 14.64 | 3178 | 1908 | 2.18 / 387.46 | 13 | 59 |
3 | 13 | 1919.96 | 20 | 14.62 | 3070 | 898 | 3.08 / 388.35 | 6 | 64 |
4 | 13 | 1269.52 | 20 | 14.66 | 2221 | 651 | 3.73 / 389.00 | 6 | 73 |
5 | 13 | 723.60 | 20 | 14.76 | 1483 | 438 | 4.17 / 389.44 | 6 | 79 |
6 | 13 | 46.28 | 20 | 14.98 | 517 | 155 | 4.32 / 389.60 | 6 | 68 |
7 | 13 | 27.84 | 20 | 14.97 | 482 | 144 | 4.47 / 389.74 | 6 | 72 |
8 | 8 | -0.04 | 210 | 14.91 | 418 | 1309 | 5.78 / 391.05 | 6 | 129 |
Average= | 7.11 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.24 | 35 | 14.91 | 515 | 269 | 0.27 / 379.85 | 6 | 16 |
2 | 7 | 2007.08 | 40 | 14.65 | 3179 | 1863 | 2.13 / 381.71 | 16 | 60 |
3 | 13 | 1917.84 | 20 | 14.62 | 3075 | 899 | 3.03 / 382.61 | 6 | 64 |
4 | 13 | 1269.20 | 20 | 14.67 | 2224 | 653 | 3.68 / 383.26 | 6 | 75 |
5 | 13 | 627.88 | 20 | 14.79 | 1356 | 401 | 4.08 / 383.66 | 6 | 81 |
6 | 13 | 49.96 | 20 | 14.98 | 523 | 157 | 4.24 / 383.82 | 6 | 75 |
7 | 13 | 16.36 | 20 | 14.98 | 464 | 139 | 4.38 / 383.96 | 6 | 70 |
8 | 8 | -0.12 | 210 | 14.91 | 420 | 1315 | 5.70 / 385.27 | 6 | 132 |
Average= | 7.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.84 | 35 | 14.92 | 534 | 279 | 0.28 / 374.22 | 6 | 17 |
2 | 7 | 2010.20 | 40 | 14.64 | 3182 | 1863 | 2.14 / 376.08 | 17 | 59 |
3 | 13 | 1813.20 | 20 | 14.63 | 2937 | 859 | 3.00 / 376.94 | 6 | 69 |
4 | 13 | 1264.72 | 20 | 14.67 | 2200 | 645 | 3.65 / 377.59 | 6 | 75 |
5 | 13 | 519.08 | 20 | 14.84 | 1191 | 353 | 4.00 / 377.94 | 6 | 80 |
6 | 13 | 47.00 | 20 | 14.98 | 523 | 157 | 4.16 / 378.10 | 6 | 70 |
7 | 13 | 14.04 | 20 | 14.98 | 465 | 139 | 4.30 / 378.24 | 6 | 73 |
8 | 8 | -0.16 | 213 | 14.91 | 423 | 1343 | 5.64 / 379.58 | 6 | 139 |
Average= | 7.16 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.44 | 36 | 14.91 | 531 | 285 | 0.29 / 368.55 | 6 | 18 |
2 | 7 | 2004.20 | 40 | 14.65 | 3184 | 1866 | 2.15 / 370.42 | 18 | 60 |
3 | 13 | 1907.68 | 20 | 14.63 | 3057 | 894 | 3.05 / 371.31 | 6 | 64 |
4 | 13 | 1255.56 | 20 | 14.68 | 2177 | 639 | 3.68 / 371.95 | 6 | 73 |
5 | 13 | 615.20 | 20 | 14.81 | 1317 | 390 | 4.07 / 372.34 | 6 | 85 |
6 | 13 | 48.08 | 20 | 14.99 | 512 | 153 | 4.23 / 372.50 | 6 | 70 |
7 | 13 | 14.00 | 20 | 14.99 | 457 | 137 | 4.37 / 372.63 | 6 | 67 |
8 | 8 | -0.12 | 212 | 14.92 | 413 | 1306 | 5.67 / 373.94 | 6 | 134 |
Average= | 7.19 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.76 | 36 | 14.92 | 534 | 287 | 0.29 / 362.81 | 6 | 17 |
2 | 7 | 2005.96 | 40 | 14.66 | 3151 | 1848 | 2.13 / 364.66 | 17 | 59 |
3 | 13 | 1910.96 | 20 | 14.63 | 3073 | 899 | 3.03 / 365.56 | 6 | 64 |
4 | 13 | 1267.96 | 20 | 14.68 | 2206 | 648 | 3.68 / 366.21 | 6 | 75 |
5 | 13 | 827.32 | 20 | 14.75 | 1603 | 473 | 4.15 / 366.68 | 6 | 78 |
6 | 13 | 59.52 | 20 | 14.98 | 529 | 158 | 4.31 / 366.84 | 6 | 75 |
7 | 8 | -0.04 | 231 | 14.93 | 414 | 1428 | 5.74 / 368.27 | 6 | 134 |
Average= | 7.22 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.24 | 36 | 14.92 | 530 | 285 | 0.28 / 356.98 | 6 | 17 |
2 | 7 | 2004.72 | 40 | 14.66 | 3161 | 1854 | 2.14 / 358.83 | 17 | 62 |
3 | 13 | 1908.20 | 20 | 14.64 | 3038 | 890 | 3.03 / 359.72 | 6 | 66 |
4 | 13 | 1581.32 | 20 | 14.63 | 2610 | 764 | 3.79 / 360.49 | 6 | 69 |
5 | 13 | 755.24 | 20 | 14.78 | 1507 | 445 | 4.24 / 360.93 | 6 | 85 |
6 | 13 | 52.64 | 20 | 15.00 | 518 | 155 | 4.39 / 361.09 | 6 | 77 |
7 | 13 | 14.16 | 20 | 15.00 | 449 | 135 | 4.53 / 361.22 | 6 | 73 |
8 | 8 | -0.08 | 212 | 14.93 | 412 | 1304 | 5.83 / 362.53 | 6 | 132 |
Average= | 7.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.68 | 36 | 14.93 | 525 | 282 | 0.28 / 351.26 | 6 | 19 |
2 | 7 | 2004.52 | 40 | 14.67 | 3157 | 1853 | 2.13 / 353.11 | 19 | 61 |
3 | 13 | 1912.56 | 20 | 14.64 | 3040 | 890 | 3.02 / 354.00 | 6 | 65 |
4 | 13 | 1267.08 | 20 | 14.69 | 2198 | 646 | 3.67 / 354.64 | 6 | 74 |
5 | 13 | 739.00 | 20 | 14.78 | 1486 | 439 | 4.11 / 355.08 | 6 | 81 |
6 | 13 | 82.48 | 20 | 14.98 | 558 | 167 | 4.28 / 355.25 | 6 | 77 |
7 | 8 | 0.00 | 236 | 14.93 | 410 | 1445 | 5.72 / 356.70 | 6 | 140 |
Average= | 7.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.00 | 36 | 14.94 | 526 | 283 | 0.28 / 345.56 | 6 | 16 |
2 | 7 | 2006.12 | 40 | 14.67 | 3168 | 1859 | 2.14 / 347.42 | 16 | 59 |
3 | 13 | 1912.60 | 20 | 14.65 | 3059 | 896 | 3.04 / 348.32 | 6 | 63 |
4 | 13 | 1260.32 | 20 | 14.69 | 2188 | 643 | 3.68 / 348.96 | 6 | 76 |
5 | 13 | 720.84 | 20 | 14.79 | 1459 | 432 | 4.11 / 349.39 | 6 | 81 |
6 | 13 | 49.68 | 20 | 15.01 | 500 | 150 | 4.26 / 349.54 | 6 | 67 |
7 | 13 | 13.32 | 20 | 15.01 | 441 | 132 | 4.40 / 349.68 | 6 | 72 |
8 | 8 | -0.08 | 214 | 14.94 | 406 | 1298 | 5.69 / 350.97 | 6 | 138 |
Average= | 7.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 36 | 14.93 | 513 | 276 | 0.28 / 339.85 | 6 | 17 |
2 | 7 | 2009.76 | 40 | 14.68 | 3133 | 1840 | 2.12 / 341.69 | 17 | 59 |
3 | 13 | 1916.00 | 20 | 14.65 | 3064 | 898 | 3.01 / 342.59 | 6 | 63 |
4 | 13 | 1262.04 | 20 | 14.69 | 2200 | 646 | 3.66 / 343.24 | 6 | 77 |
5 | 13 | 824.08 | 20 | 14.76 | 1603 | 473 | 4.13 / 343.71 | 6 | 85 |
6 | 13 | 37.32 | 20 | 15.01 | 486 | 146 | 4.28 / 343.86 | 6 | 66 |
7 | 8 | -0.04 | 233 | 14.94 | 409 | 1424 | 5.70 / 345.28 | 6 | 135 |
Average= | 7.35 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.64 | 36 | 14.93 | 537 | 289 | 0.29 / 334.26 | 6 | 24 |
2 | 7 | 2007.48 | 40 | 14.67 | 3155 | 1851 | 2.14 / 336.11 | 24 | 60 |
3 | 13 | 1916.08 | 20 | 14.65 | 3040 | 891 | 3.03 / 337.00 | 6 | 63 |
4 | 13 | 1183.12 | 20 | 14.72 | 2070 | 609 | 3.64 / 337.61 | 6 | 76 |
5 | 13 | 640.92 | 20 | 14.82 | 1358 | 403 | 4.04 / 338.01 | 6 | 89 |
6 | 13 | 52.64 | 20 | 15.01 | 514 | 154 | 4.20 / 338.16 | 6 | 77 |
7 | 8 | 0.00 | 231 | 14.94 | 410 | 1415 | 5.61 / 339.58 | 6 | 129 |
Average= | 7.38 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.92 | 35 | 14.95 | 530 | 277 | 0.28 / 328.49 | 6 | 22 |
2 | 7 | 2005.56 | 40 | 14.69 | 3160 | 1857 | 2.13 / 330.34 | 22 | 60 |
3 | 13 | 1914.44 | 20 | 14.65 | 3058 | 896 | 3.03 / 331.24 | 6 | 65 |
4 | 13 | 1268.04 | 20 | 14.71 | 2194 | 645 | 3.68 / 331.88 | 6 | 75 |
5 | 13 | 836.88 | 20 | 14.77 | 1616 | 477 | 4.15 / 332.36 | 6 | 80 |
6 | 13 | 73.68 | 20 | 15.01 | 540 | 162 | 4.32 / 332.52 | 6 | 71 |
7 | 13 | 15.92 | 20 | 15.01 | 451 | 135 | 4.45 / 332.66 | 6 | 72 |
8 | 8 | -0.08 | 212 | 14.94 | 413 | 1308 | 5.76 / 333.97 | 6 | 137 |
Average= | 7.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 115.36 | 35 | 14.95 | 547 | 286 | 0.29 / 322.83 | 6 | 26 |
2 | 7 | 2004.84 | 40 | 14.68 | 3162 | 1857 | 2.14 / 324.68 | 26 | 59 |
3 | 13 | 1907.20 | 20 | 14.66 | 3016 | 884 | 3.03 / 325.57 | 6 | 66 |
4 | 13 | 1269.80 | 20 | 14.71 | 2208 | 650 | 3.68 / 326.22 | 6 | 74 |
5 | 13 | 724.60 | 20 | 14.81 | 1467 | 435 | 4.11 / 326.65 | 6 | 80 |
6 | 13 | 37.28 | 20 | 15.03 | 478 | 144 | 4.26 / 326.80 | 6 | 70 |
7 | 8 | -0.08 | 232 | 14.96 | 407 | 1413 | 5.67 / 328.21 | 6 | 132 |
Average= | 7.46 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.56 | 35 | 14.96 | 530 | 278 | 0.28 / 317.15 | 6 | 24 |
2 | 7 | 2013.84 | 40 | 14.67 | 3167 | 1858 | 2.14 / 319.01 | 24 | 56 |
3 | 13 | 1812.36 | 20 | 14.66 | 2938 | 861 | 3.00 / 319.87 | 6 | 67 |
4 | 13 | 1381.48 | 20 | 14.68 | 2362 | 693 | 3.69 / 320.57 | 6 | 73 |
5 | 13 | 716.72 | 20 | 14.81 | 1456 | 431 | 4.12 / 321.00 | 6 | 80 |
6 | 13 | 33.00 | 20 | 15.03 | 475 | 143 | 4.26 / 321.14 | 6 | 76 |
7 | 8 | -0.04 | 229 | 14.96 | 409 | 1401 | 5.67 / 322.54 | 6 | 130 |
Average= | 7.50 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.44 | 35 | 14.96 | 532 | 279 | 0.28 / 311.52 | 6 | 24 |
2 | 7 | 2005.36 | 40 | 14.69 | 3134 | 1842 | 2.12 / 313.37 | 24 | 59 |
3 | 13 | 1907.40 | 20 | 14.66 | 3008 | 882 | 3.00 / 314.25 | 6 | 65 |
4 | 13 | 1252.32 | 20 | 14.72 | 2171 | 639 | 3.64 / 314.89 | 6 | 75 |
5 | 13 | 701.80 | 20 | 14.82 | 1438 | 426 | 4.07 / 315.31 | 6 | 82 |
6 | 13 | 31.12 | 20 | 15.04 | 472 | 142 | 4.21 / 315.46 | 6 | 70 |
7 | 8 | -0.04 | 229 | 14.97 | 414 | 1419 | 5.63 / 316.87 | 6 | 133 |
Average= | 7.54 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.12 | 35 | 14.97 | 532 | 279 | 0.28 / 305.91 | 6 | 24 |
2 | 7 | 2004.84 | 40 | 14.68 | 3146 | 1847 | 2.13 / 307.76 | 24 | 61 |
3 | 13 | 1906.64 | 20 | 14.67 | 3018 | 885 | 3.01 / 308.64 | 6 | 66 |
4 | 13 | 1260.76 | 20 | 14.72 | 2188 | 644 | 3.66 / 309.29 | 6 | 75 |
5 | 13 | 626.52 | 20 | 14.85 | 1342 | 399 | 4.05 / 309.69 | 6 | 85 |
6 | 13 | 24.04 | 20 | 15.04 | 463 | 139 | 4.19 / 309.83 | 6 | 75 |
7 | 8 | -0.04 | 229 | 14.97 | 414 | 1419 | 5.61 / 311.25 | 6 | 138 |
Average= | 7.59 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.60 | 35 | 14.97 | 531 | 278 | 0.28 / 300.24 | 6 | 19 |
2 | 7 | 2012.52 | 40 | 14.69 | 3143 | 1847 | 2.13 / 302.09 | 19 | 61 |
3 | 13 | 1916.08 | 20 | 14.67 | 3029 | 889 | 3.01 / 302.98 | 6 | 64 |
4 | 13 | 1370.52 | 20 | 14.70 | 2343 | 689 | 3.70 / 303.67 | 6 | 75 |
5 | 13 | 714.96 | 20 | 14.83 | 1452 | 431 | 4.13 / 304.10 | 6 | 84 |
6 | 13 | 22.12 | 20 | 15.05 | 457 | 138 | 4.27 / 304.24 | 6 | 72 |
7 | 8 | -0.04 | 229 | 14.98 | 407 | 1396 | 5.67 / 305.63 | 6 | 140 |
Average= | 7.64 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.40 | 35 | 14.97 | 522 | 274 | 0.27 / 294.67 | 6 | 21 |
2 | 7 | 2005.60 | 40 | 14.69 | 3134 | 1842 | 2.12 / 296.51 | 21 | 58 |
3 | 13 | 1809.56 | 20 | 14.69 | 2872 | 844 | 2.96 / 297.35 | 6 | 69 |
4 | 13 | 1276.76 | 20 | 14.72 | 2206 | 649 | 3.61 / 298.00 | 6 | 74 |
5 | 13 | 632.32 | 20 | 14.85 | 1349 | 401 | 4.01 / 298.40 | 6 | 80 |
6 | 13 | 42.48 | 20 | 15.05 | 496 | 149 | 4.16 / 298.55 | 6 | 74 |
7 | 8 | -0.12 | 229 | 14.98 | 412 | 1413 | 5.57 / 299.97 | 6 | 130 |
Average= | 7.69 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.08 | 35 | 14.98 | 535 | 281 | 0.28 / 289.06 | 6 | 24 |
2 | 7 | 2005.24 | 40 | 14.69 | 3153 | 1853 | 2.13 / 290.91 | 24 | 60 |
3 | 13 | 1810.68 | 20 | 14.68 | 2925 | 859 | 2.99 / 291.77 | 6 | 67 |
4 | 13 | 1274.92 | 20 | 14.72 | 2215 | 652 | 3.64 / 292.42 | 6 | 75 |
5 | 13 | 720.84 | 20 | 14.84 | 1469 | 436 | 4.08 / 292.86 | 6 | 82 |
6 | 13 | 31.72 | 20 | 15.05 | 480 | 144 | 4.22 / 293.00 | 6 | 79 |
7 | 8 | 0.04 | 227 | 14.99 | 410 | 1395 | 5.62 / 294.39 | 6 | 133 |
Average= | 7.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 35 | 14.99 | 532 | 279 | 0.28 / 283.33 | 6 | 23 |
2 | 7 | 2006.40 | 41 | 14.69 | 3144 | 1894 | 2.17 / 285.23 | 23 | 60 |
3 | 13 | 1911.32 | 20 | 14.68 | 3034 | 891 | 3.06 / 286.12 | 6 | 65 |
4 | 13 | 1358.40 | 20 | 14.71 | 2320 | 683 | 3.75 / 286.80 | 6 | 74 |
5 | 13 | 703.76 | 20 | 14.85 | 1445 | 429 | 4.18 / 287.23 | 6 | 82 |
6 | 13 | 33.52 | 20 | 15.06 | 485 | 146 | 4.32 / 287.38 | 6 | 75 |
7 | 8 | 0.04 | 227 | 14.99 | 411 | 1399 | 5.72 / 288.78 | 6 | 134 |
Average= | 7.80 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.00 | 35 | 14.99 | 525 | 275 | 0.28 / 277.74 | 6 | 17 |
2 | 7 | 2007.08 | 40 | 14.69 | 3150 | 1851 | 2.13 / 279.59 | 17 | 60 |
3 | 13 | 1813.76 | 20 | 14.68 | 2928 | 860 | 2.99 / 280.45 | 6 | 67 |
4 | 13 | 1271.40 | 20 | 14.73 | 2211 | 651 | 3.64 / 281.10 | 6 | 78 |
5 | 13 | 609.24 | 20 | 14.88 | 1321 | 393 | 4.03 / 281.49 | 6 | 87 |
6 | 13 | 34.76 | 20 | 15.06 | 488 | 147 | 4.18 / 281.64 | 6 | 72 |
7 | 8 | 0.00 | 227 | 14.99 | 416 | 1416 | 5.59 / 283.06 | 6 | 134 |
Average= | 7.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.08 | 35 | 15.00 | 530 | 278 | 0.28 / 272.20 | 6 | 22 |
2 | 7 | 2003.96 | 40 | 14.69 | 3173 | 1864 | 2.14 / 274.07 | 22 | 63 |
3 | 13 | 1804.72 | 20 | 14.69 | 2902 | 853 | 3.00 / 274.92 | 6 | 67 |
4 | 13 | 1149.08 | 20 | 14.77 | 2038 | 602 | 3.60 / 275.52 | 6 | 77 |
5 | 13 | 611.80 | 20 | 14.88 | 1315 | 391 | 3.99 / 275.91 | 6 | 87 |
6 | 13 | 34.44 | 20 | 15.06 | 481 | 145 | 4.13 / 276.06 | 6 | 68 |
7 | 8 | -0.04 | 227 | 15.00 | 413 | 1406 | 5.54 / 277.46 | 6 | 137 |
Average= | 7.93 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.32 | 35 | 15.01 | 503 | 264 | 0.26 / 266.62 | 6 | 10 |
2 | 7 | 2003.36 | 40 | 14.70 | 3138 | 1845 | 2.11 / 268.47 | 10 | 62 |
3 | 13 | 1814.00 | 20 | 14.69 | 2915 | 856 | 2.97 / 269.33 | 6 | 67 |
4 | 13 | 1282.36 | 20 | 14.74 | 2218 | 654 | 3.62 / 269.98 | 6 | 75 |
5 | 13 | 630.84 | 20 | 14.87 | 1351 | 402 | 4.02 / 270.38 | 6 | 82 |
6 | 13 | 38.92 | 20 | 15.07 | 487 | 147 | 4.17 / 270.53 | 6 | 80 |
7 | 8 | -0.12 | 225 | 15.00 | 413 | 1394 | 5.56 / 271.92 | 6 | 135 |
Average= | 8.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 35 | 15.01 | 499 | 262 | 0.26 / 260.97 | 6 | 17 |
2 | 7 | 2005.96 | 40 | 14.69 | 3168 | 1862 | 2.12 / 262.83 | 17 | 62 |
3 | 13 | 1910.52 | 20 | 14.69 | 3039 | 893 | 3.02 / 263.73 | 6 | 67 |
4 | 13 | 1264.68 | 20 | 14.74 | 2218 | 654 | 3.67 / 264.38 | 6 | 77 |
5 | 13 | 715.16 | 20 | 14.86 | 1451 | 431 | 4.10 / 264.81 | 6 | 85 |
6 | 13 | 63.08 | 20 | 15.06 | 525 | 158 | 4.26 / 264.97 | 6 | 79 |
7 | 13 | 17.04 | 20 | 15.07 | 443 | 134 | 4.39 / 265.10 | 6 | 73 |
8 | 8 | -0.12 | 210 | 15.01 | 399 | 1258 | 5.65 / 266.36 | 6 | 132 |
Average= | 8.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.84 | 35 | 15.02 | 491 | 258 | 0.26 / 255.40 | 6 | 12 |
2 | 7 | 2003.16 | 40 | 14.70 | 3163 | 1860 | 2.12 / 257.26 | 12 | 60 |
3 | 13 | 1804.60 | 20 | 14.70 | 2908 | 855 | 2.97 / 258.12 | 6 | 68 |
4 | 13 | 1181.04 | 20 | 14.77 | 2086 | 616 | 3.59 / 258.73 | 6 | 77 |
5 | 13 | 744.56 | 20 | 14.85 | 1484 | 441 | 4.03 / 259.18 | 6 | 82 |
6 | 13 | 47.20 | 20 | 15.07 | 490 | 148 | 4.18 / 259.32 | 6 | 70 |
7 | 13 | 27.68 | 20 | 15.07 | 457 | 138 | 4.32 / 259.46 | 6 | 69 |
8 | 8 | -0.12 | 208 | 15.01 | 400 | 1249 | 5.56 / 260.71 | 6 | 135 |
Average= | 8.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.32 | 34 | 15.03 | 496 | 253 | 0.25 / 249.81 | 6 | 18 |
2 | 7 | 2005.12 | 40 | 14.70 | 3180 | 1870 | 2.12 / 251.68 | 18 | 62 |
3 | 13 | 1908.24 | 20 | 14.67 | 3074 | 902 | 3.03 / 252.58 | 6 | 65 |
4 | 13 | 1230.76 | 20 | 14.77 | 2145 | 634 | 3.66 / 253.21 | 6 | 79 |
5 | 13 | 580.08 | 20 | 14.91 | 1277 | 381 | 4.04 / 253.59 | 6 | 87 |
6 | 13 | 57.04 | 20 | 15.07 | 518 | 156 | 4.20 / 253.75 | 6 | 72 |
7 | 13 | 18.20 | 20 | 15.07 | 453 | 137 | 4.33 / 253.89 | 6 | 77 |
8 | 8 | -0.08 | 208 | 15.02 | 403 | 1259 | 5.59 / 255.15 | 6 | 133 |
Average= | 8.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.76 | 34 | 15.03 | 499 | 255 | 0.25 / 244.16 | 6 | 12 |
2 | 7 | 2006.00 | 41 | 14.72 | 3127 | 1887 | 2.14 / 246.04 | 12 | 61 |
3 | 13 | 1911.52 | 20 | 14.68 | 3049 | 895 | 3.04 / 246.94 | 6 | 65 |
4 | 13 | 1358.36 | 20 | 14.74 | 2312 | 682 | 3.72 / 247.62 | 6 | 74 |
5 | 13 | 589.04 | 20 | 14.91 | 1281 | 382 | 4.10 / 248.00 | 6 | 83 |
6 | 13 | 61.88 | 20 | 15.08 | 519 | 157 | 4.26 / 248.16 | 6 | 74 |
7 | 13 | 35.36 | 20 | 15.08 | 474 | 143 | 4.40 / 248.30 | 6 | 74 |
8 | 8 | 0.00 | 210 | 15.02 | 397 | 1252 | 5.65 / 249.55 | 6 | 133 |
Average= | 8.32 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.00 | 34 | 15.04 | 485 | 248 | 0.25 / 238.58 | 6 | 15 |
2 | 7 | 2007.36 | 40 | 14.70 | 3175 | 1867 | 2.11 / 240.45 | 15 | 60 |
3 | 13 | 1908.44 | 20 | 14.69 | 3031 | 891 | 3.01 / 241.34 | 6 | 65 |
4 | 13 | 1258.96 | 20 | 14.77 | 2173 | 642 | 3.65 / 241.98 | 6 | 76 |
5 | 13 | 614.20 | 20 | 14.91 | 1309 | 390 | 4.04 / 242.37 | 6 | 85 |
6 | 13 | 76.20 | 20 | 15.08 | 537 | 162 | 4.20 / 242.53 | 6 | 78 |
7 | 13 | 24.08 | 20 | 15.08 | 450 | 136 | 4.34 / 242.67 | 6 | 69 |
8 | 8 | 0.08 | 210 | 15.03 | 391 | 1234 | 5.57 / 243.90 | 6 | 135 |
Average= | 8.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.92 | 34 | 15.03 | 498 | 254 | 0.25 / 232.89 | 6 | 16 |
2 | 7 | 2004.48 | 41 | 14.70 | 3163 | 1906 | 2.16 / 234.80 | 16 | 60 |
3 | 13 | 1907.24 | 20 | 14.69 | 3033 | 891 | 3.05 / 235.69 | 6 | 66 |
4 | 13 | 1348.08 | 20 | 14.75 | 2301 | 679 | 3.73 / 236.37 | 6 | 77 |
5 | 13 | 785.36 | 20 | 14.86 | 1539 | 457 | 4.19 / 236.82 | 6 | 83 |
6 | 13 | 50.88 | 20 | 15.09 | 496 | 150 | 4.34 / 236.97 | 6 | 75 |
7 | 13 | 30.28 | 20 | 15.09 | 461 | 139 | 4.48 / 237.11 | 6 | 74 |
8 | 8 | 0.00 | 210 | 15.03 | 386 | 1218 | 5.70 / 238.33 | 6 | 137 |
Average= | 8.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.20 | 34 | 15.04 | 491 | 251 | 0.25 / 227.33 | 6 | 13 |
2 | 7 | 2004.68 | 40 | 14.72 | 3137 | 1847 | 2.10 / 229.17 | 13 | 61 |
3 | 13 | 1906.56 | 20 | 14.71 | 3001 | 883 | 2.98 / 230.06 | 6 | 68 |
4 | 13 | 1259.92 | 20 | 14.77 | 2191 | 647 | 3.63 / 230.70 | 6 | 77 |
5 | 13 | 616.36 | 20 | 14.91 | 1326 | 395 | 4.02 / 231.10 | 6 | 85 |
6 | 13 | 46.60 | 20 | 15.09 | 493 | 149 | 4.17 / 231.25 | 6 | 75 |
7 | 13 | 26.68 | 20 | 15.09 | 457 | 138 | 4.31 / 231.39 | 6 | 72 |
8 | 8 | -0.08 | 208 | 15.03 | 400 | 1250 | 5.56 / 232.64 | 6 | 138 |
Average= | 8.62 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.16 | 34 | 15.05 | 484 | 248 | 0.25 / 221.74 | 6 | 17 |
2 | 7 | 2004.40 | 40 | 14.71 | 3159 | 1859 | 2.11 / 223.60 | 17 | 62 |
3 | 13 | 1907.72 | 20 | 14.70 | 3004 | 883 | 2.99 / 224.49 | 6 | 66 |
4 | 13 | 1249.52 | 20 | 14.78 | 2169 | 641 | 3.63 / 225.13 | 6 | 76 |
5 | 13 | 704.12 | 20 | 14.90 | 1430 | 426 | 4.06 / 225.55 | 6 | 84 |
6 | 13 | 41.68 | 20 | 15.10 | 486 | 147 | 4.20 / 225.70 | 6 | 75 |
7 | 13 | 17.40 | 20 | 15.10 | 442 | 133 | 4.34 / 225.83 | 6 | 71 |
8 | 8 | -0.12 | 210 | 15.04 | 393 | 1241 | 5.58 / 227.08 | 6 | 135 |
Average= | 8.73 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.32 | 34 | 15.05 | 489 | 250 | 0.25 / 216.23 | 6 | 17 |
2 | 7 | 2006.16 | 40 | 14.72 | 3135 | 1846 | 2.10 / 218.07 | 17 | 62 |
3 | 13 | 1911.44 | 20 | 14.69 | 3060 | 899 | 3.00 / 218.97 | 6 | 65 |
4 | 13 | 1254.64 | 20 | 14.79 | 2167 | 641 | 3.64 / 219.61 | 6 | 77 |
5 | 13 | 603.68 | 20 | 14.93 | 1301 | 388 | 4.02 / 220.00 | 6 | 86 |
6 | 13 | 39.68 | 20 | 15.10 | 476 | 144 | 4.17 / 220.15 | 6 | 74 |
7 | 13 | 12.40 | 20 | 15.10 | 429 | 130 | 4.30 / 220.28 | 6 | 71 |
8 | 8 | 0.04 | 208 | 15.05 | 390 | 1221 | 5.52 / 221.50 | 6 | 132 |
Average= | 8.86 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.52 | 34 | 15.05 | 499 | 255 | 0.26 / 210.69 | 6 | 13 |
2 | 7 | 2004.12 | 40 | 14.72 | 3138 | 1848 | 2.10 / 212.53 | 13 | 62 |
3 | 13 | 1908.00 | 20 | 14.70 | 3049 | 896 | 3.00 / 213.43 | 6 | 66 |
4 | 13 | 1258.76 | 20 | 14.78 | 2185 | 646 | 3.65 / 214.08 | 6 | 77 |
5 | 13 | 616.64 | 20 | 14.93 | 1316 | 393 | 4.04 / 214.47 | 6 | 84 |
6 | 13 | 40.28 | 20 | 15.11 | 478 | 144 | 4.18 / 214.61 | 6 | 72 |
7 | 13 | 12.24 | 20 | 15.11 | 429 | 130 | 4.31 / 214.74 | 6 | 73 |
8 | 8 | 0.28 | 208 | 15.04 | 395 | 1236 | 5.55 / 215.98 | 6 | 133 |
Average= | 9.00 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.40 | 34 | 15.06 | 506 | 259 | 0.26 / 205.11 | 6 | 17 |
2 | 7 | 2004.24 | 41 | 14.73 | 3129 | 1890 | 2.15 / 207.00 | 17 | 61 |
3 | 13 | 1905.76 | 20 | 14.71 | 3038 | 894 | 3.04 / 207.89 | 6 | 67 |
4 | 13 | 1253.76 | 20 | 14.79 | 2177 | 644 | 3.69 / 208.53 | 6 | 77 |
5 | 13 | 601.04 | 20 | 14.94 | 1297 | 388 | 4.07 / 208.92 | 6 | 85 |
6 | 13 | 37.84 | 20 | 15.11 | 474 | 143 | 4.22 / 209.07 | 6 | 72 |
7 | 13 | 12.44 | 20 | 15.11 | 426 | 129 | 4.35 / 209.19 | 6 | 73 |
8 | 8 | -0.04 | 208 | 15.05 | 395 | 1237 | 5.58 / 210.43 | 6 | 137 |
Average= | 9.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.28 | 35 | 15.06 | 489 | 258 | 0.26 / 199.55 | 6 | 17 |
2 | 7 | 2006.44 | 40 | 14.73 | 3141 | 1851 | 2.11 / 201.40 | 17 | 61 |
3 | 13 | 1914.48 | 20 | 14.72 | 2989 | 880 | 2.99 / 202.28 | 6 | 65 |
4 | 13 | 1355.52 | 20 | 14.77 | 2294 | 678 | 3.67 / 202.95 | 6 | 76 |
5 | 13 | 609.24 | 20 | 14.94 | 1297 | 388 | 4.05 / 203.34 | 6 | 84 |
6 | 13 | 40.68 | 20 | 15.12 | 471 | 142 | 4.20 / 203.48 | 6 | 72 |
7 | 13 | 15.80 | 20 | 15.12 | 431 | 130 | 4.33 / 203.61 | 6 | 70 |
8 | 8 | -0.08 | 210 | 15.06 | 390 | 1233 | 5.56 / 204.85 | 6 | 136 |
Average= | 9.31 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.40 | 35 | 15.05 | 512 | 270 | 0.27 / 193.95 | 6 | 19 |
2 | 7 | 2005.00 | 40 | 14.73 | 3134 | 1847 | 2.12 / 195.80 | 19 | 62 |
3 | 13 | 1908.44 | 20 | 14.73 | 2983 | 879 | 3.00 / 196.68 | 6 | 66 |
4 | 13 | 1267.28 | 20 | 14.80 | 2190 | 648 | 3.64 / 197.33 | 6 | 77 |
5 | 13 | 729.00 | 20 | 14.91 | 1453 | 433 | 4.08 / 197.76 | 6 | 83 |
6 | 13 | 37.00 | 20 | 15.12 | 468 | 142 | 4.22 / 197.90 | 6 | 73 |
7 | 13 | 15.76 | 20 | 15.12 | 435 | 132 | 4.35 / 198.03 | 6 | 71 |
8 | 8 | -0.04 | 210 | 15.06 | 397 | 1256 | 5.61 / 199.29 | 6 | 132 |
Average= | 9.49 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.92 | 35 | 15.07 | 482 | 254 | 0.25 / 188.44 | 6 | 15 |
2 | 7 | 2004.88 | 40 | 14.73 | 3147 | 1854 | 2.11 / 190.29 | 15 | 62 |
3 | 13 | 1815.52 | 20 | 14.73 | 2916 | 859 | 2.97 / 191.15 | 6 | 68 |
4 | 13 | 1191.00 | 20 | 14.81 | 2082 | 617 | 3.58 / 191.77 | 6 | 78 |
5 | 13 | 653.88 | 20 | 14.93 | 1362 | 407 | 3.99 / 192.17 | 6 | 85 |
6 | 13 | 41.12 | 20 | 15.12 | 477 | 144 | 4.14 / 192.32 | 6 | 75 |
7 | 13 | 10.12 | 20 | 15.12 | 425 | 129 | 4.26 / 192.45 | 6 | 73 |
8 | 8 | -0.08 | 208 | 15.06 | 395 | 1237 | 5.50 / 193.68 | 6 | 137 |
Average= | 9.68 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.96 | 35 | 15.07 | 490 | 258 | 0.26 / 182.91 | 6 | 18 |
2 | 7 | 2004.68 | 40 | 14.74 | 3144 | 1854 | 2.11 / 184.76 | 18 | 63 |
3 | 13 | 1909.52 | 20 | 14.72 | 3008 | 886 | 3.00 / 185.65 | 6 | 66 |
4 | 13 | 1254.08 | 20 | 14.80 | 2159 | 639 | 3.64 / 186.29 | 6 | 76 |
5 | 13 | 602.76 | 20 | 14.95 | 1288 | 385 | 4.02 / 186.67 | 6 | 84 |
6 | 13 | 34.72 | 20 | 15.13 | 467 | 141 | 4.16 / 186.82 | 6 | 75 |
7 | 13 | 10.12 | 20 | 15.13 | 420 | 127 | 4.29 / 186.94 | 6 | 73 |
8 | 8 | -0.08 | 210 | 15.06 | 392 | 1240 | 5.53 / 188.18 | 6 | 139 |
Average= | 9.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.20 | 35 | 15.07 | 492 | 260 | 0.26 / 177.32 | 6 | 18 |
2 | 7 | 2003.96 | 41 | 14.74 | 3128 | 1890 | 2.15 / 179.21 | 18 | 62 |
3 | 13 | 1905.08 | 20 | 14.72 | 3007 | 885 | 3.04 / 180.10 | 6 | 65 |
4 | 13 | 1340.52 | 20 | 14.79 | 2285 | 676 | 3.71 / 180.77 | 6 | 75 |
5 | 13 | 666.08 | 20 | 14.94 | 1373 | 410 | 4.12 / 181.18 | 6 | 85 |
6 | 13 | 25.28 | 20 | 15.14 | 440 | 133 | 4.25 / 181.32 | 6 | 72 |
7 | 13 | 6.92 | 20 | 15.14 | 409 | 124 | 4.38 / 181.44 | 6 | 73 |
8 | 8 | -0.08 | 208 | 15.07 | 386 | 1210 | 5.59 / 182.65 | 6 | 134 |
Average= | 10.15 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.92 | 35 | 15.07 | 490 | 258 | 0.26 / 171.72 | 6 | 19 |
2 | 7 | 2004.08 | 41 | 14.73 | 3140 | 1896 | 2.15 / 173.62 | 19 | 62 |
3 | 13 | 1907.24 | 20 | 14.71 | 3032 | 892 | 3.05 / 174.51 | 6 | 67 |
4 | 13 | 1358.32 | 20 | 14.78 | 2317 | 685 | 3.73 / 175.19 | 6 | 76 |
5 | 13 | 597.92 | 20 | 14.96 | 1288 | 385 | 4.12 / 175.58 | 6 | 86 |
6 | 13 | 36.20 | 20 | 15.13 | 460 | 139 | 4.26 / 175.72 | 6 | 74 |
7 | 13 | 9.56 | 20 | 15.14 | 416 | 126 | 4.38 / 175.84 | 6 | 74 |
8 | 8 | 0.00 | 208 | 15.07 | 389 | 1219 | 5.60 / 177.06 | 6 | 134 |
Average= | 10.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.80 | 35 | 15.08 | 487 | 257 | 0.26 / 166.13 | 6 | 20 |
2 | 7 | 2003.16 | 40 | 14.74 | 3168 | 1868 | 2.12 / 168.00 | 20 | 63 |
3 | 13 | 1904.60 | 20 | 14.73 | 3048 | 898 | 3.02 / 168.89 | 6 | 67 |
4 | 13 | 1250.20 | 20 | 14.82 | 2168 | 643 | 3.67 / 169.54 | 6 | 78 |
5 | 13 | 696.96 | 20 | 14.93 | 1418 | 423 | 4.09 / 169.96 | 6 | 85 |
6 | 13 | 59.48 | 20 | 15.13 | 500 | 151 | 4.24 / 170.11 | 6 | 75 |
7 | 13 | 13.72 | 20 | 15.14 | 425 | 129 | 4.37 / 170.24 | 6 | 73 |
8 | 8 | -0.12 | 208 | 15.07 | 390 | 1222 | 5.59 / 171.46 | 6 | 137 |
Average= | 10.72 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.96 | 35 | 15.09 | 490 | 259 | 0.26 / 160.56 | 6 | 20 |
2 | 7 | 2004.72 | 40 | 14.73 | 3174 | 1870 | 2.13 / 162.43 | 20 | 64 |
3 | 13 | 1908.80 | 20 | 14.72 | 3043 | 896 | 3.02 / 163.33 | 6 | 67 |
4 | 13 | 1245.40 | 20 | 14.82 | 2165 | 642 | 3.67 / 163.97 | 6 | 78 |
5 | 13 | 688.16 | 20 | 14.94 | 1409 | 421 | 4.09 / 164.39 | 6 | 87 |
6 | 13 | 49.16 | 20 | 15.14 | 482 | 146 | 4.23 / 164.53 | 6 | 76 |
7 | 13 | 12.64 | 20 | 15.14 | 422 | 128 | 4.36 / 164.66 | 6 | 73 |
8 | 8 | -0.12 | 206 | 15.08 | 389 | 1208 | 5.57 / 165.87 | 6 | 132 |
Average= | 11.06 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.04 | 35 | 15.09 | 490 | 259 | 0.26 / 155.06 | 6 | 18 |
2 | 7 | 2011.96 | 41 | 14.74 | 3160 | 1910 | 2.17 / 156.97 | 18 | 63 |
3 | 13 | 1816.24 | 20 | 14.74 | 2934 | 865 | 3.03 / 157.84 | 6 | 69 |
4 | 13 | 1371.92 | 20 | 14.79 | 2333 | 690 | 3.72 / 158.53 | 6 | 76 |
5 | 13 | 500.12 | 20 | 15.00 | 1146 | 344 | 4.07 / 158.87 | 6 | 85 |
6 | 13 | 43.96 | 20 | 15.14 | 474 | 144 | 4.21 / 159.02 | 6 | 74 |
7 | 8 | -0.04 | 227 | 15.09 | 375 | 1285 | 5.50 / 160.30 | 6 | 138 |
Average= | 11.45 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 103.64 | 35 | 15.09 | 493 | 260 | 0.26 / 149.56 | 6 | 19 |
2 | 7 | 2005.20 | 40 | 14.75 | 3129 | 1846 | 2.11 / 151.41 | 19 | 62 |
3 | 13 | 1909.04 | 20 | 14.74 | 3016 | 889 | 3.00 / 152.30 | 6 | 67 |
4 | 13 | 1255.40 | 20 | 14.83 | 2160 | 641 | 3.64 / 152.94 | 6 | 77 |
5 | 13 | 699.08 | 20 | 14.94 | 1420 | 424 | 4.06 / 153.36 | 6 | 85 |
6 | 13 | 60.16 | 20 | 15.14 | 497 | 150 | 4.21 / 153.51 | 6 | 74 |
7 | 8 | -0.04 | 229 | 15.10 | 374 | 1293 | 5.50 / 154.81 | 6 | 135 |
Average= | 11.91 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.04 | 35 | 15.09 | 481 | 254 | 0.25 / 144.06 | 6 | 21 |
2 | 7 | 2012.76 | 40 | 14.76 | 3136 | 1851 | 2.11 / 145.91 | 21 | 61 |
3 | 13 | 1815.76 | 20 | 14.77 | 2887 | 853 | 2.96 / 146.77 | 6 | 68 |
4 | 13 | 1189.64 | 20 | 14.84 | 2086 | 619 | 3.58 / 147.38 | 6 | 79 |
5 | 13 | 757.48 | 20 | 14.93 | 1497 | 447 | 4.02 / 147.83 | 6 | 84 |
6 | 13 | 45.92 | 20 | 15.15 | 479 | 145 | 4.17 / 147.98 | 6 | 74 |
7 | 8 | -0.12 | 229 | 15.10 | 383 | 1324 | 5.49 / 149.30 | 6 | 133 |
Average= | 12.44 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.04 | 35 | 15.10 | 480 | 254 | 0.25 / 138.47 | 6 | 21 |
2 | 7 | 2004.48 | 40 | 14.76 | 3129 | 1847 | 2.10 / 140.32 | 21 | 62 |
3 | 13 | 1907.92 | 20 | 14.75 | 3010 | 888 | 2.99 / 141.21 | 6 | 67 |
4 | 13 | 1246.40 | 20 | 14.84 | 2154 | 639 | 3.63 / 141.84 | 6 | 77 |
5 | 13 | 810.52 | 20 | 14.92 | 1558 | 465 | 4.09 / 142.31 | 6 | 83 |
6 | 13 | 58.24 | 20 | 15.15 | 499 | 151 | 4.24 / 142.46 | 6 | 75 |
7 | 8 | 0.20 | 231 | 15.10 | 386 | 1346 | 5.59 / 143.81 | 6 | 141 |
Average= | 13.07 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.28 | 35 | 15.10 | 490 | 259 | 0.26 / 133.02 | 6 | 22 |
2 | 7 | 2003.20 | 40 | 14.76 | 3125 | 1845 | 2.10 / 134.87 | 22 | 59 |
3 | 13 | 1811.08 | 20 | 14.77 | 2898 | 856 | 2.96 / 135.72 | 6 | 67 |
4 | 13 | 1276.68 | 20 | 14.83 | 2200 | 653 | 3.61 / 136.38 | 6 | 75 |
5 | 13 | 622.40 | 20 | 14.98 | 1309 | 392 | 4.00 / 136.77 | 6 | 84 |
6 | 13 | 41.48 | 20 | 15.16 | 467 | 142 | 4.15 / 136.91 | 6 | 73 |
7 | 8 | -0.04 | 227 | 15.11 | 381 | 1307 | 5.45 / 138.22 | 6 | 132 |
Average= | 13.82 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 114.52 | 35 | 15.10 | 504 | 266 | 0.27 / 127.44 | 6 | 23 |
2 | 7 | 2006.88 | 40 | 14.76 | 3120 | 1842 | 2.11 / 129.29 | 23 | 59 |
3 | 13 | 1914.20 | 20 | 14.75 | 3021 | 891 | 3.00 / 130.18 | 6 | 64 |
4 | 13 | 1361.36 | 20 | 14.82 | 2306 | 683 | 3.68 / 130.86 | 6 | 74 |
5 | 13 | 696.24 | 20 | 14.97 | 1409 | 422 | 4.10 / 131.28 | 6 | 82 |
6 | 13 | 36.44 | 20 | 15.17 | 460 | 140 | 4.24 / 131.42 | 6 | 72 |
7 | 8 | -0.04 | 231 | 15.11 | 384 | 1340 | 5.58 / 132.76 | 6 | 135 |
Average= | 14.75 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.72 | 35 | 15.11 | 518 | 274 | 0.27 / 121.83 | 6 | 24 |
2 | 7 | 2004.80 | 40 | 14.78 | 3103 | 1834 | 2.11 / 123.67 | 24 | 59 |
3 | 13 | 1909.36 | 20 | 14.76 | 3003 | 886 | 2.99 / 124.56 | 6 | 65 |
4 | 13 | 1364.56 | 20 | 14.83 | 2281 | 677 | 3.67 / 125.23 | 6 | 72 |
5 | 13 | 806.08 | 20 | 14.94 | 1547 | 462 | 4.13 / 125.69 | 6 | 80 |
6 | 13 | 46.68 | 20 | 15.16 | 479 | 145 | 4.28 / 125.84 | 6 | 73 |
7 | 8 | 0.00 | 229 | 15.11 | 387 | 1339 | 5.62 / 127.18 | 6 | 132 |
Average= | 15.90 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 35 | 15.10 | 508 | 268 | 0.27 / 116.30 | 6 | 25 |
2 | 7 | 2006.24 | 40 | 14.77 | 3140 | 1855 | 2.12 / 118.15 | 25 | 61 |
3 | 13 | 1913.28 | 20 | 14.76 | 3024 | 893 | 3.02 / 119.04 | 6 | 65 |
4 | 13 | 1261.48 | 20 | 14.85 | 2161 | 642 | 3.66 / 119.69 | 6 | 75 |
5 | 13 | 622.80 | 20 | 15.00 | 1310 | 393 | 4.05 / 120.08 | 6 | 84 |
6 | 13 | 23.12 | 20 | 15.18 | 435 | 132 | 4.18 / 120.21 | 6 | 73 |
7 | 8 | -0.04 | 229 | 15.11 | 390 | 1349 | 5.53 / 121.56 | 6 | 143 |
Average= | 17.37 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.68 | 35 | 15.11 | 511 | 270 | 0.27 / 110.78 | 6 | 24 |
2 | 7 | 2006.68 | 40 | 14.77 | 3144 | 1857 | 2.13 / 112.63 | 24 | 61 |
3 | 13 | 1912.76 | 20 | 14.76 | 3039 | 897 | 3.02 / 113.53 | 5 | 65 |
4 | 13 | 1251.28 | 20 | 14.86 | 2160 | 642 | 3.67 / 114.17 | 6 | 76 |
5 | 13 | 611.96 | 20 | 15.00 | 1302 | 391 | 4.06 / 114.56 | 6 | 83 |
6 | 13 | 41.00 | 20 | 15.17 | 469 | 142 | 4.20 / 114.71 | 6 | 73 |
7 | 8 | 0.04 | 227 | 15.12 | 385 | 1321 | 5.52 / 116.03 | 6 | 131 |
Average= | 19.34 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 106.64 | 35 | 15.12 | 511 | 270 | 0.27 / 105.25 | 6 | 26 |
2 | 7 | 2004.72 | 40 | 14.77 | 3153 | 1863 | 2.13 / 107.12 | 26 | 62 |
3 | 13 | 1908.28 | 20 | 14.76 | 3039 | 897 | 3.03 / 108.01 | 6 | 65 |
4 | 13 | 1143.64 | 20 | 14.89 | 2020 | 602 | 3.63 / 108.61 | 6 | 77 |
5 | 13 | 699.76 | 20 | 14.98 | 1415 | 424 | 4.06 / 109.04 | 6 | 84 |
6 | 13 | 27.04 | 20 | 15.18 | 446 | 135 | 4.19 / 109.17 | 6 | 75 |
7 | 8 | 0.00 | 225 | 15.12 | 392 | 1334 | 5.52 / 110.51 | 6 | 135 |
Average= | 22.10 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 107.72 | 35 | 15.12 | 510 | 270 | 0.27 / 99.65 | 6 | 25 |
2 | 7 | 2006.28 | 40 | 14.77 | 3169 | 1872 | 2.14 / 101.52 | 25 | 61 |
3 | 13 | 1908.68 | 20 | 14.77 | 3029 | 895 | 3.04 / 102.42 | 6 | 64 |
4 | 13 | 1249.80 | 20 | 14.86 | 2174 | 646 | 3.68 / 103.06 | 6 | 75 |
5 | 13 | 789.48 | 20 | 14.95 | 1543 | 461 | 4.14 / 103.53 | 6 | 83 |
6 | 13 | 20.32 | 20 | 15.19 | 434 | 132 | 4.28 / 103.66 | 6 | 73 |
7 | 8 | 0.00 | 227 | 15.12 | 386 | 1325 | 5.60 / 104.98 | 6 | 134 |
Average= | 26.25 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 110.96 | 35 | 15.12 | 503 | 266 | 0.27 / 94.15 | 6 | 26 |
2 | 7 | 2007.72 | 40 | 14.78 | 3114 | 1841 | 2.11 / 95.99 | 26 | 59 |
3 | 13 | 1911.72 | 20 | 14.78 | 2996 | 886 | 2.99 / 96.87 | 6 | 65 |
4 | 13 | 1245.72 | 20 | 14.87 | 2135 | 635 | 3.63 / 97.51 | 6 | 75 |
5 | 13 | 701.64 | 20 | 14.98 | 1414 | 424 | 4.05 / 97.93 | 6 | 82 |
6 | 13 | 28.08 | 20 | 15.19 | 441 | 134 | 4.19 / 98.07 | 6 | 75 |
7 | 8 | -0.08 | 227 | 15.13 | 383 | 1315 | 5.50 / 99.38 | 6 | 131 |
Average= | 33.13 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.64 | 35 | 15.13 | 506 | 268 | 0.27 / 88.69 | 6 | 24 |
2 | 7 | 2005.04 | 40 | 14.79 | 3129 | 1851 | 2.12 / 90.54 | 24 | 60 |
3 | 13 | 1911.44 | 20 | 14.78 | 3030 | 896 | 3.01 / 91.44 | 6 | 65 |
4 | 13 | 1150.04 | 20 | 14.90 | 2012 | 600 | 3.61 / 92.03 | 6 | 77 |
5 | 13 | 619.40 | 20 | 15.01 | 1304 | 391 | 4.01 / 92.43 | 6 | 83 |
6 | 13 | 29.64 | 20 | 15.19 | 445 | 135 | 4.14 / 92.56 | 6 | 75 |
7 | 8 | -0.08 | 227 | 15.13 | 384 | 1319 | 5.46 / 93.88 | 6 | 136 |
Average= | 46.94 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 105.40 | 34 | 15.14 | 490 | 252 | 0.25 / 83.23 | 6 | 23 |
2 | 7 | 2005.24 | 40 | 14.79 | 3140 | 1858 | 2.11 / 85.09 | 25 | 60 |
3 | 13 | 1912.00 | 20 | 14.79 | 3004 | 889 | 3.00 / 85.98 | 6 | 64 |
4 | 13 | 1178.00 | 20 | 14.91 | 2029 | 605 | 3.60 / 86.59 | 6 | 75 |
5 | 13 | 645.68 | 20 | 15.00 | 1337 | 401 | 4.00 / 86.99 | 6 | 82 |
6 | 13 | 23.60 | 20 | 15.20 | 430 | 131 | 4.14 / 87.12 | 6 | 73 |
7 | 8 | -0.04 | 227 | 15.14 | 379 | 1303 | 5.44 / 88.42 | 6 | 131 |
Average= | 88.42 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 100.00 | 34 | 15.15 | 469 | 242 | 0.24 / 77.73 | 6 | 19 |
2 | 7 | 2012.44 | 40 | 14.80 | 3135 | 1856 | 2.10 / 79.58 | 39 | 60 |
3 | 13 | 1913.68 | 20 | 14.79 | 3009 | 890 | 2.99 / 80.47 | 6 | 64 |
4 | 13 | 1358.68 | 20 | 14.86 | 2282 | 678 | 3.67 / 81.15 | 6 | 73 |
5 | 13 | 685.16 | 20 | 15.01 | 1377 | 413 | 4.08 / 81.56 | 6 | 82 |
6 | 13 | 31.96 | 20 | 15.20 | 441 | 134 | 4.21 / 81.70 | 6 | 73 |
7 | 8 | 0.00 | 229 | 15.15 | 370 | 1284 | 5.50 / 82.98 | 6 | 135 |
Average= | 4.88 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.00 | 34 | 15.15 | 477 | 246 | 0.25 / 72.37 | 6 | 19 |
2 | 7 | 2004.68 | 40 | 14.80 | 3132 | 1854 | 2.10 / 74.22 | 19 | 60 |
3 | 13 | 1908.20 | 20 | 14.80 | 3010 | 891 | 2.99 / 75.11 | 6 | 64 |
4 | 13 | 1063.12 | 20 | 14.94 | 1869 | 558 | 3.55 / 75.67 | 6 | 76 |
5 | 13 | 647.00 | 20 | 15.02 | 1320 | 397 | 3.95 / 76.07 | 6 | 82 |
6 | 13 | 38.16 | 20 | 15.20 | 447 | 136 | 4.08 / 76.20 | 6 | 75 |
7 | 8 | -0.08 | 229 | 15.15 | 370 | 1284 | 5.37 / 77.49 | 6 | 139 |
Average= | 4.84 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 34 | 15.17 | 468 | 241 | 0.24 / 66.87 | 6 | 17 |
2 | 7 | 2005.00 | 40 | 14.81 | 3138 | 1859 | 2.10 / 68.73 | 31 | 61 |
3 | 13 | 1914.20 | 20 | 14.81 | 2993 | 887 | 2.99 / 69.61 | 6 | 65 |
4 | 13 | 1258.28 | 20 | 14.89 | 2160 | 643 | 3.63 / 70.26 | 6 | 76 |
5 | 13 | 708.84 | 20 | 15.01 | 1408 | 423 | 4.05 / 70.68 | 6 | 83 |
6 | 13 | 63.84 | 20 | 15.20 | 489 | 149 | 4.20 / 70.83 | 6 | 75 |
7 | 13 | 12.68 | 20 | 15.20 | 409 | 124 | 4.33 / 70.95 | 6 | 74 |
8 | 8 | -0.08 | 210 | 15.15 | 367 | 1168 | 5.49 / 72.12 | 6 | 137 |
Average= | 4.81 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 104.84 | 34 | 15.17 | 457 | 236 | 0.24 / 61.43 | 6 | 16 |
2 | 7 | 2004.32 | 40 | 14.81 | 3146 | 1864 | 2.10 / 63.29 | 16 | 61 |
3 | 13 | 1905.52 | 20 | 14.81 | 3009 | 891 | 2.99 / 64.18 | 6 | 65 |
4 | 13 | 1245.92 | 20 | 14.90 | 2139 | 637 | 3.63 / 64.82 | 6 | 76 |
5 | 13 | 698.20 | 20 | 15.01 | 1402 | 421 | 4.05 / 65.24 | 6 | 82 |
6 | 13 | 18.68 | 20 | 15.22 | 411 | 125 | 4.17 / 65.37 | 6 | 71 |
7 | 8 | -0.04 | 231 | 15.17 | 360 | 1262 | 5.44 / 66.63 | 6 | 131 |
Average= | 4.76 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.60 | 34 | 15.17 | 482 | 249 | 0.25 / 56.00 | 6 | 16 |
2 | 7 | 2004.64 | 40 | 14.82 | 3124 | 1852 | 2.10 / 57.85 | 16 | 62 |
3 | 13 | 1907.12 | 20 | 14.82 | 3002 | 890 | 2.99 / 58.74 | 6 | 65 |
4 | 13 | 1235.28 | 20 | 14.90 | 2135 | 636 | 3.63 / 59.37 | 6 | 75 |
5 | 13 | 685.76 | 20 | 15.02 | 1391 | 418 | 4.04 / 59.79 | 6 | 83 |
6 | 13 | 45.56 | 20 | 15.21 | 461 | 140 | 4.18 / 59.93 | 6 | 74 |
7 | 13 | 15.40 | 20 | 15.21 | 403 | 123 | 4.31 / 60.05 | 6 | 73 |
8 | 8 | -0.12 | 210 | 15.16 | 357 | 1137 | 5.44 / 61.19 | 6 | 135 |
Average= | 4.71 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 101.36 | 34 | 15.17 | 462 | 238 | 0.24 / 50.64 | 6 | 16 |
2 | 7 | 2013.08 | 40 | 14.82 | 3118 | 1848 | 2.09 / 52.49 | 16 | 60 |
3 | 13 | 1819.24 | 20 | 14.83 | 2872 | 852 | 2.94 / 53.34 | 6 | 66 |
4 | 13 | 1277.80 | 20 | 14.89 | 2172 | 647 | 3.59 / 53.99 | 6 | 74 |
5 | 13 | 619.84 | 20 | 15.04 | 1282 | 386 | 3.97 / 54.37 | 6 | 82 |
6 | 13 | 22.96 | 20 | 15.22 | 415 | 126 | 4.10 / 54.50 | 6 | 72 |
7 | 8 | -0.04 | 231 | 15.17 | 356 | 1248 | 5.34 / 55.75 | 6 | 141 |
Average= | 4.65 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.04 | 34 | 15.17 | 473 | 244 | 0.24 / 45.33 | 6 | 16 |
2 | 7 | 2004.00 | 41 | 14.82 | 3101 | 1884 | 2.13 / 47.21 | 16 | 60 |
3 | 13 | 1815.24 | 20 | 14.83 | 2885 | 856 | 2.98 / 48.07 | 6 | 67 |
4 | 13 | 1165.36 | 20 | 14.93 | 2018 | 603 | 3.59 / 48.67 | 6 | 75 |
5 | 13 | 524.96 | 20 | 15.08 | 1152 | 347 | 3.93 / 49.02 | 6 | 83 |
6 | 13 | 27.72 | 20 | 15.22 | 426 | 130 | 4.06 / 49.15 | 6 | 73 |
7 | 8 | 0.04 | 229 | 15.17 | 362 | 1258 | 5.32 / 50.40 | 6 | 131 |
Average= | 4.58 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.80 | 34 | 15.17 | 458 | 236 | 0.24 / 39.89 | 6 | 15 |
2 | 7 | 2011.16 | 40 | 14.83 | 3134 | 1859 | 2.10 / 41.75 | 15 | 60 |
3 | 13 | 1813.16 | 20 | 14.84 | 2853 | 847 | 2.94 / 42.60 | 6 | 65 |
4 | 13 | 1264.08 | 20 | 14.91 | 2153 | 642 | 3.58 / 43.24 | 6 | 75 |
5 | 13 | 714.60 | 20 | 15.02 | 1412 | 424 | 4.01 / 43.66 | 6 | 82 |
6 | 13 | 63.36 | 20 | 15.22 | 476 | 145 | 4.15 / 43.81 | 6 | 75 |
7 | 13 | 17.00 | 20 | 15.22 | 404 | 123 | 4.28 / 43.93 | 6 | 73 |
8 | 8 | -0.04 | 212 | 15.17 | 358 | 1151 | 5.43 / 45.08 | 6 | 137 |
Average= | 4.51 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.44 | 34 | 15.17 | 470 | 242 | 0.24 / 34.48 | 6 | 16 |
2 | 7 | 2003.08 | 40 | 14.83 | 3140 | 1863 | 2.11 / 36.34 | 32 | 62 |
3 | 13 | 1905.48 | 20 | 14.83 | 3013 | 894 | 3.00 / 37.24 | 6 | 65 |
4 | 13 | 1247.28 | 20 | 14.91 | 2146 | 640 | 3.64 / 37.88 | 6 | 76 |
5 | 13 | 606.96 | 20 | 15.05 | 1270 | 382 | 4.02 / 38.26 | 6 | 84 |
6 | 13 | 34.72 | 20 | 15.23 | 438 | 133 | 4.15 / 38.39 | 6 | 74 |
7 | 13 | 12.24 | 20 | 15.22 | 394 | 120 | 4.27 / 38.51 | 6 | 72 |
8 | 8 | -0.08 | 210 | 15.17 | 358 | 1140 | 5.41 / 39.65 | 6 | 137 |
Average= | 4.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 102.12 | 33 | 15.17 | 447 | 224 | 0.22 / 29.05 | 6 | 17 |
2 | 7 | 2003.52 | 40 | 14.84 | 3129 | 1857 | 2.08 / 30.91 | 34 | 62 |
3 | 13 | 1905.52 | 20 | 14.84 | 2995 | 889 | 2.97 / 31.80 | 6 | 65 |
4 | 13 | 1249.72 | 20 | 14.92 | 2140 | 639 | 3.61 / 32.43 | 6 | 75 |
5 | 13 | 696.84 | 20 | 15.03 | 1393 | 419 | 4.03 / 32.85 | 6 | 83 |
6 | 13 | 29.76 | 20 | 15.23 | 426 | 130 | 4.16 / 32.98 | 6 | 73 |
7 | 13 | 11.08 | 20 | 15.23 | 392 | 119 | 4.28 / 33.10 | 6 | 72 |
8 | 8 | -0.08 | 210 | 15.17 | 357 | 1137 | 5.41 / 34.24 | 6 | 135 |
Average= | 4.28 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 111.36 | 32 | 15.17 | 474 | 230 | 0.23 / 23.74 | 6 | 14 |
2 | 3 | 1062.92 | 2 | 15.18 | 1875 | 57 | 0.29 / 23.80 | 6 | 69 |
3 | 7 | 2008.20 | 40 | 14.85 | 3123 | 1855 | 2.14 / 25.65 | 69 | 61 |
4 | 13 | 1708.32 | 20 | 14.87 | 2752 | 818 | 2.96 / 26.47 | 6 | 68 |
5 | 13 | 1286.44 | 20 | 14.92 | 2185 | 652 | 3.61 / 27.12 | 6 | 75 |
6 | 13 | 525.84 | 20 | 15.09 | 1148 | 346 | 3.96 / 27.47 | 6 | 83 |
7 | 13 | 26.32 | 20 | 15.23 | 418 | 127 | 4.09 / 27.60 | 6 | 73 |
8 | 8 | -0.08 | 229 | 15.18 | 353 | 1227 | 5.31 / 28.83 | 6 | 135 |
Average= | 4.12 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 112.16 | 31 | 15.18 | 476 | 224 | 0.22 / 18.39 | 6 | 16 |
2 | 3 | 1034.52 | 1 | 15.22 | 1856 | 28 | 0.25 / 18.42 | 6 | 54 |
3 | 7 | 2004.28 | 40 | 14.86 | 3120 | 1855 | 2.11 / 20.28 | 54 | 60 |
4 | 13 | 1806.84 | 20 | 14.87 | 2870 | 854 | 2.96 / 21.13 | 6 | 67 |
5 | 13 | 1164.04 | 20 | 14.95 | 2024 | 605 | 3.57 / 21.73 | 6 | 76 |
6 | 13 | 612.52 | 20 | 15.06 | 1275 | 384 | 3.95 / 22.12 | 6 | 83 |
7 | 13 | 36.20 | 20 | 15.23 | 439 | 134 | 4.08 / 22.25 | 6 | 75 |
8 | 13 | 12.84 | 20 | 15.23 | 402 | 122 | 4.21 / 22.37 | 6 | 73 |
9 | 8 | -0.04 | 210 | 15.17 | 357 | 1137 | 5.34 / 23.51 | 6 | 136 |
Average= | 3.92 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.28 | 32 | 15.18 | 469 | 228 | 0.23 / 13.88 | 6 | 17 |
2 | 7 | 1508.24 | 40 | 15.00 | 2486 | 1492 | 1.72 / 15.37 | 14 | 67 |
3 | 13 | 1426.12 | 20 | 14.99 | 2374 | 712 | 2.43 / 16.08 | 6 | 71 |
4 | 13 | 916.20 | 20 | 15.05 | 1683 | 507 | 2.94 / 16.59 | 6 | 79 |
5 | 13 | 275.28 | 20 | 15.19 | 792 | 241 | 3.18 / 16.83 | 6 | 81 |
6 | 13 | 30.84 | 20 | 15.25 | 427 | 130 | 3.31 / 16.96 | 6 | 75 |
7 | 8 | -0.04 | 223 | 15.20 | 356 | 1207 | 4.52 / 18.17 | 6 | 134 |
Average= | 3.63 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 108.16 | 32 | 15.17 | 474 | 230 | 0.23 / 9.30 | 6 | 16 |
2 | 7 | 1509.80 | 40 | 15.01 | 2475 | 1486 | 1.72 / 10.79 | 16 | 66 |
3 | 13 | 1426.60 | 20 | 14.99 | 2377 | 713 | 2.43 / 11.50 | 6 | 70 |
4 | 13 | 1109.24 | 20 | 15.01 | 1928 | 579 | 3.01 / 12.08 | 6 | 75 |
5 | 13 | 245.64 | 20 | 15.20 | 746 | 227 | 3.23 / 12.31 | 6 | 80 |
6 | 13 | 31.12 | 20 | 15.25 | 429 | 131 | 3.37 / 12.44 | 6 | 74 |
7 | 8 | -0.04 | 225 | 15.20 | 355 | 1214 | 4.58 / 13.65 | 6 | 136 |
Average= | 3.41 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 109.44 | 31 | 15.22 | 470 | 222 | 0.22 / 4.68 | 6 | 18 |
2 | 3 | 1034.04 | 1 | 15.23 | 1848 | 28 | 0.25 / 4.71 | 6 | 46 |
3 | 7 | 1511.80 | 40 | 15.02 | 2454 | 1474 | 1.72 / 6.19 | 46 | 66 |
4 | 13 | 1429.80 | 20 | 15.00 | 2354 | 706 | 2.43 / 6.89 | 6 | 69 |
5 | 13 | 1015.48 | 20 | 15.03 | 1813 | 545 | 2.98 / 7.44 | 6 | 77 |
6 | 13 | 360.00 | 20 | 15.16 | 910 | 276 | 3.25 / 7.71 | 6 | 83 |
7 | 13 | 27.84 | 20 | 15.24 | 422 | 129 | 3.38 / 7.84 | 6 | 76 |
8 | 8 | 0.00 | 225 | 15.19 | 361 | 1234 | 4.61 / 9.07 | 6 | 135 |
Average= | 3.02 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 113.00 | 31 | 15.48 | 431 | 207 | 0.21 / 1.75 | 6 | 12 |
2 | 7 | 991.48 | 40 | 15.15 | 1751 | 1061 | 1.27 / 2.81 | 12 | 73 |
3 | 13 | 448.16 | 20 | 15.23 | 1021 | 311 | 1.58 / 3.12 | 6 | 79 |
4 | 13 | 41.08 | 20 | 15.32 | 437 | 134 | 1.71 / 3.25 | 6 | 74 |
5 | 8 | 0.04 | 225 | 15.26 | 352 | 1209 | 2.92 / 4.46 | 6 | 133 |
Average= | 2.23 (KJ/cycle) |
Number | Code | Pressure (db) |
Pump Time (s) |
Voltage (V) |
Current (ma) |
Energy (J) |
Cumulative Energy (KJ) |
Vacuum0 (load-start) |
Vacuum1 (load-stop) |
1 | 2 | 71.80 | 30 | 15.64 | 378 | 177 | 0.18 / 0.18 | 6 | 12 |
2 | 7 | 81.72 | 40 | 15.62 | 385 | 241 | 0.42 / 0.42 | 12 | 15 |
3 | 13 | 47.32 | 20 | 15.61 | 334 | 104 | 0.52 / 0.52 | 6 | 18 |
4 | 13 | 27.60 | 20 | 15.60 | 313 | 98 | 0.62 / 0.62 | 6 | 20 |
5 | 8 | -0.04 | 223 | 15.56 | 265 | 920 | 1.54 / 1.54 | 6 | 137 |
Average= | 1.54 (KJ/cycle) |