SIO Argo Site:
Pump Diagnostics Page   



Serial= 7655 WMO= 1902397

Return

←PreviousNext→

Cycle 87 GMT 6/ 5/2024 21:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 40 14.95 431 258 0.26 / 505.12 5 14
2 7 2011.60 40 14.63 3092 1809 2.07 / 506.93 14 52
3 13 1927.16 20 14.62 2997 876 2.94 / 507.81 5 55
4 13 1515.96 20 14.63 2458 719 3.66 / 508.53 5 63
5 13 1058.12 20 14.70 1845 542 4.21 / 509.07 5 72
6 13 395.28 20 14.90 926 276 4.48 / 509.35 5 77
7 13 31.92 20 15.02 374 112 4.59 / 509.46 5 56
8 8 -0.04 314 14.96 311 1461 6.05 / 510.92 5 146
Average= 8.11
(KJ/cycle)

Cycle 86 GMT 27/ 4/2024 0:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 40 14.96 440 263 0.26 / 499.27 5 14
2 7 2006.24 40 14.63 3093 1810 2.07 / 501.08 14 51
3 13 1913.88 20 14.61 2974 869 2.94 / 501.95 5 56
4 13 1377.64 20 14.66 2272 666 3.61 / 502.61 5 66
5 13 767.16 20 14.79 1452 430 4.04 / 503.04 5 74
6 13 429.12 20 14.88 976 290 4.33 / 503.33 5 78
7 13 34.08 20 15.02 372 112 4.44 / 503.45 5 58
8 8 -0.12 312 14.96 304 1419 5.86 / 504.86 5 137
Average= 8.14
(KJ/cycle)

Cycle 85 GMT 17/ 4/2024 3:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 40 14.96 442 264 0.26 / 493.38 5 15
2 7 2005.48 40 14.63 3096 1812 2.08 / 495.19 15 53
3 13 1915.16 20 14.61 2979 870 2.95 / 496.06 5 56
4 13 1483.00 20 14.64 2410 706 3.65 / 496.77 5 63
5 13 1039.84 20 14.70 1822 536 4.19 / 497.31 5 71
6 13 253.80 20 14.95 713 213 4.40 / 497.52 5 69
7 13 27.84 20 15.03 357 107 4.51 / 497.63 5 54
8 8 -0.08 304 14.97 303 1379 5.89 / 499.00 5 133
Average= 8.18
(KJ/cycle)

Cycle 84 GMT 7/ 4/2024 6:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 40 14.96 427 256 0.26 / 487.28 5 13
2 7 2003.44 40 14.63 3087 1807 2.06 / 489.09 13 53
3 13 1908.88 20 14.62 2962 866 2.93 / 489.95 5 57
4 13 1696.04 20 14.59 2689 785 3.71 / 490.74 5 61
5 13 1100.04 20 14.69 1907 560 4.27 / 491.30 5 70
6 13 421.92 20 14.89 962 286 4.56 / 491.58 5 75
7 13 38.28 20 15.02 383 115 4.67 / 491.70 5 56
8 8 -0.04 306 14.96 310 1419 6.09 / 493.12 5 140
Average= 8.22
(KJ/cycle)

Cycle 83 GMT 28/ 3/2024 10: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.80 40 14.95 435 260 0.26 / 481.42 5 13
2 7 2015.56 40 14.64 3098 1814 2.07 / 483.23 13 52
3 13 1932.20 20 14.62 2993 875 2.95 / 484.10 5 56
4 13 1423.44 20 14.65 2332 683 3.63 / 484.79 5 64
5 13 894.68 20 14.75 1619 478 4.11 / 485.27 5 73
6 13 377.20 20 14.91 889 265 4.38 / 485.53 5 72
7 13 24.56 20 15.02 354 106 4.48 / 485.64 5 53
8 8 -0.08 306 14.96 303 1387 5.87 / 487.02 5 139
Average= 8.25
(KJ/cycle)

Cycle 82 GMT 18/ 3/2024 13: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 40 14.95 431 258 0.26 / 475.39 5 12
2 7 2005.60 40 14.64 3090 1810 2.07 / 477.19 12 52
3 13 1914.20 20 14.62 2970 868 2.94 / 478.06 5 55
4 13 1413.64 20 14.65 2315 678 3.61 / 478.74 5 64
5 13 994.88 20 14.72 1755 517 4.13 / 479.26 5 72
6 13 643.84 20 14.80 1274 377 4.51 / 479.64 5 76
7 13 30.28 20 15.02 366 110 4.62 / 479.74 5 55
8 8 -0.12 308 14.96 306 1410 6.03 / 481.15 5 137
Average= 8.30
(KJ/cycle)

Cycle 81 GMT 8/ 3/2024 16: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 40 14.95 454 271 0.27 / 469.49 5 13
2 7 2015.00 41 14.63 3105 1862 2.13 / 471.36 13 51
3 13 1934.04 20 14.61 3000 877 3.01 / 472.23 5 56
4 13 1419.56 20 14.64 2331 683 3.69 / 472.91 5 64
5 13 1107.28 20 14.68 1915 562 4.26 / 473.48 5 70
6 13 234.36 20 14.96 681 204 4.46 / 473.68 5 65
7 8 -0.12 321 14.97 301 1446 5.91 / 475.13 5 144
Average= 8.34
(KJ/cycle)

Cycle 80 GMT 27/ 2/2024 18:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.20 40 14.96 429 257 0.26 / 463.61 5 13
2 7 2015.48 40 14.63 3097 1812 2.07 / 465.42 13 52
3 13 1930.36 20 14.61 3001 877 2.95 / 466.30 5 56
4 13 1513.04 20 14.63 2442 715 3.66 / 467.01 5 63
5 13 872.16 20 14.75 1595 471 4.13 / 467.48 5 73
6 13 344.08 20 14.92 844 252 4.38 / 467.73 5 71
7 13 27.20 20 15.03 356 107 4.49 / 467.84 5 54
8 8 -0.08 302 14.96 306 1382 5.87 / 469.22 5 134
Average= 8.38
(KJ/cycle)

Cycle 79 GMT 17/ 2/2024 21:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 40 14.95 432 258 0.26 / 457.79 5 13
2 7 2016.80 40 14.64 3102 1817 2.07 / 459.61 13 51
3 13 1925.48 20 14.62 2991 875 2.95 / 460.48 5 56
4 13 1487.84 20 14.64 2413 707 3.66 / 461.19 5 63
5 13 862.88 20 14.76 1578 466 4.12 / 461.65 5 73
6 13 334.76 20 14.93 827 247 4.37 / 461.90 5 69
7 13 24.44 20 15.03 353 106 4.47 / 462.01 5 52
8 8 -0.16 300 14.97 299 1343 5.82 / 463.35 5 130
Average= 8.42
(KJ/cycle)

Cycle 78 GMT 8/ 2/2024 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 40 14.94 458 274 0.27 / 451.68 5 14
2 7 2005.32 41 14.64 3082 1850 2.12 / 453.53 14 52
3 13 1914.64 20 14.62 2974 870 2.99 / 454.40 5 55
4 13 1711.88 20 14.59 2702 788 3.78 / 455.18 5 60
5 13 1130.80 20 14.68 1936 568 4.35 / 455.75 5 70
6 13 365.40 20 14.92 873 261 4.61 / 456.01 5 73
7 13 28.12 20 15.03 359 108 4.72 / 456.12 5 54
8 8 -0.12 310 14.97 304 1411 6.13 / 457.53 5 133
Average= 8.47
(KJ/cycle)

Cycle 77 GMT 29/ 1/2024 4: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 40 14.96 435 260 0.26 / 445.51 5 14
2 7 2010.40 40 14.65 3095 1814 2.07 / 447.32 14 52
3 13 1923.88 20 14.63 2974 870 2.94 / 448.19 5 55
4 13 1602.76 20 14.62 2564 750 3.69 / 448.94 5 61
5 13 1174.64 20 14.67 1991 584 4.28 / 449.53 5 68
6 13 485.04 20 14.86 1052 313 4.59 / 449.84 5 76
7 13 25.92 20 15.02 361 108 4.70 / 449.95 5 53
8 8 -0.28 314 14.96 310 1456 6.16 / 451.40 5 135
Average= 8.52
(KJ/cycle)

Cycle 76 GMT 19/ 1/2024 7:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.28 40 14.94 440 263 0.26 / 439.59 5 15
2 7 2005.60 40 14.65 3091 1811 2.07 / 441.40 15 52
3 13 1921.52 20 14.63 2980 872 2.95 / 442.27 5 56
4 13 1503.48 20 14.64 2436 713 3.66 / 442.98 5 63
5 13 1072.56 20 14.70 1867 549 4.21 / 443.53 5 70
6 13 312.60 20 14.93 806 241 4.45 / 443.77 5 73
7 8 -0.04 323 14.97 305 1475 5.92 / 445.25 5 132
Average= 8.56
(KJ/cycle)

Cycle 75 GMT 9/ 1/2024 10:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.80 40 14.93 468 279 0.28 / 433.62 5 15
2 7 2004.24 40 14.65 3090 1811 2.09 / 435.43 15 53
3 13 1914.16 20 14.63 2974 870 2.96 / 436.30 5 56
4 13 1401.84 20 14.66 2300 674 3.63 / 436.98 5 65
5 13 883.20 20 14.75 1610 475 4.11 / 437.45 5 74
6 13 460.12 20 14.87 1019 303 4.41 / 437.76 5 77
7 13 22.16 20 15.02 353 106 4.52 / 437.86 5 53
8 8 -0.08 317 14.96 308 1461 5.98 / 439.32 5 132
Average= 8.61
(KJ/cycle)

Cycle 74 GMT 30/12/2023 13:10:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 40 14.94 456 273 0.27 / 427.51 5 17
2 7 2017.04 40 14.64 3105 1818 2.09 / 429.33 17 52
3 13 1929.64 20 14.62 2996 876 2.97 / 430.20 5 56
4 13 1501.44 20 14.64 2433 712 3.68 / 430.92 5 64
5 13 954.92 20 14.73 1717 506 4.19 / 431.42 5 73
6 13 401.96 20 14.89 942 281 4.47 / 431.70 5 76
7 13 36.60 20 15.02 386 116 4.58 / 431.82 5 59
8 8 -0.12 319 14.95 320 1526 6.11 / 433.34 5 134
Average= 8.67
(KJ/cycle)

Cycle 73 GMT 20/12/2023 16:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 39 14.94 440 256 0.26 / 421.47 5 16
2 7 2010.72 40 14.66 3091 1813 2.07 / 423.28 16 53
3 13 1925.96 20 14.63 2993 876 2.94 / 424.16 5 56
4 13 1616.88 20 14.62 2582 755 3.70 / 424.91 5 62
5 13 936.88 20 14.74 1679 495 4.19 / 425.41 5 73
6 13 295.28 20 14.94 781 233 4.43 / 425.64 5 73
7 13 17.72 20 15.03 345 104 4.53 / 425.74 5 51
8 8 -0.08 321 14.96 311 1493 6.03 / 427.24 5 136
Average= 8.72
(KJ/cycle)

Cycle 72 GMT 10/12/2023 19:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.20 39 14.93 444 259 0.26 / 415.44 5 16
2 7 2015.76 40 14.65 3101 1817 2.08 / 417.26 16 52
3 13 1927.00 20 14.63 2986 874 2.95 / 418.13 5 55
4 13 1510.88 20 14.63 2444 715 3.66 / 418.85 5 63
5 13 1062.56 20 14.70 1851 544 4.21 / 419.39 5 70
6 13 301.88 20 14.93 784 234 4.44 / 419.63 5 75
7 8 -0.12 346 14.96 306 1584 6.03 / 421.21 5 135
Average= 8.78
(KJ/cycle)

Cycle 71 GMT 30/11/2023 22: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 39 14.93 440 256 0.26 / 409.51 5 18
2 7 2008.80 40 14.66 3087 1810 2.07 / 411.32 18 52
3 13 1926.68 20 14.64 2979 872 2.94 / 412.19 5 57
4 13 1412.20 20 14.66 2318 680 3.62 / 412.87 5 65
5 13 893.64 20 14.75 1625 479 4.10 / 413.35 5 73
6 13 266.96 20 14.94 744 222 4.32 / 413.57 5 72
7 8 0.00 351 14.96 307 1612 5.93 / 415.18 5 137
Average= 8.83
(KJ/cycle)

Cycle 70 GMT 21/11/2023 0:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 39 14.92 469 273 0.27 / 403.46 5 21
2 7 2005.16 40 14.66 3092 1813 2.09 / 405.27 21 54
3 13 1914.88 20 14.64 2967 869 2.95 / 406.14 5 56
4 13 1487.84 20 14.65 2415 708 3.66 / 406.85 5 63
5 13 853.28 20 14.76 1571 464 4.13 / 407.31 5 74
6 13 525.08 20 14.84 1110 329 4.46 / 407.64 5 78
7 8 -0.16 349 14.95 309 1612 6.07 / 409.25 5 133
Average= 8.90
(KJ/cycle)

Cycle 69 GMT 11/11/2023 3:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 39 14.93 463 270 0.27 / 397.17 5 21
2 7 2015.88 40 14.66 3097 1816 2.09 / 398.98 21 52
3 13 1924.44 20 14.64 2982 873 2.96 / 399.86 5 57
4 13 1490.96 20 14.65 2415 708 3.67 / 400.56 5 65
5 13 1062.16 20 14.71 1847 543 4.21 / 401.11 5 71
6 13 599.16 20 14.82 1221 362 4.57 / 401.47 5 78
7 8 0.00 370 14.95 310 1715 6.29 / 403.18 5 135
Average= 8.96
(KJ/cycle)

Cycle 68 GMT 1/11/2023 6:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 39 14.93 474 276 0.28 / 391.22 5 24
2 7 2003.72 40 14.66 3085 1809 2.09 / 393.03 24 52
3 13 1914.16 20 14.65 2967 869 2.95 / 393.90 5 57
4 13 1388.68 20 14.67 2284 670 3.62 / 394.57 5 65
5 13 868.36 20 14.76 1590 469 4.09 / 395.04 5 74
6 13 240.12 20 14.95 699 209 4.30 / 395.25 5 71
7 8 0.00 355 14.96 311 1652 5.95 / 396.90 5 132
Average= 9.02
(KJ/cycle)

Cycle 67 GMT 22/10/2023 9:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 39 14.93 469 273 0.27 / 385.06 5 23
2 7 2011.72 40 14.67 3087 1811 2.08 / 386.87 23 53
3 13 1923.04 20 14.64 2994 877 2.96 / 387.74 5 58
4 13 1516.44 20 14.65 2453 719 3.68 / 388.46 5 64
5 13 1064.60 20 14.70 1852 544 4.22 / 389.01 5 70
6 13 281.16 20 14.94 763 228 4.45 / 389.24 5 74
7 8 0.04 366 14.96 312 1708 6.16 / 390.94 5 144
Average= 9.09
(KJ/cycle)

Cycle 66 GMT 12/10/2023 12:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 39 14.94 459 267 0.27 / 378.88 5 21
2 7 2009.16 40 14.67 3083 1809 2.08 / 380.69 21 53
3 13 1931.76 20 14.65 2996 878 2.95 / 381.57 5 57
4 13 1539.20 20 14.64 2486 728 3.68 / 382.30 5 63
5 13 899.64 20 14.75 1632 481 4.16 / 382.78 5 73
6 13 470.64 20 14.87 1038 309 4.47 / 383.09 5 77
7 8 0.12 364 14.96 311 1694 6.17 / 384.78 5 139
Average= 9.16
(KJ/cycle)

Cycle 65 GMT 2/10/2023 15:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 39 14.93 457 266 0.27 / 372.87 5 25
2 7 2012.28 40 14.66 3100 1818 2.08 / 374.69 25 53
3 13 1933.72 20 14.64 3011 882 2.97 / 375.57 5 57
4 13 1512.76 20 14.65 2455 719 3.68 / 376.29 5 64
5 13 859.52 20 14.77 1585 468 4.15 / 376.76 5 74
6 13 322.64 20 14.93 821 245 4.40 / 377.01 5 74
7 8 -0.04 346 14.96 311 1610 6.01 / 378.62 5 136
Average= 9.23
(KJ/cycle)

Cycle 64 GMT 22/ 9/2023 18:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 39 14.94 468 273 0.27 / 366.68 5 23
2 7 2004.56 40 14.68 3088 1813 2.09 / 368.50 23 53
3 13 1909.04 20 14.66 2974 872 2.96 / 369.37 5 56
4 13 1591.84 20 14.65 2556 749 3.71 / 370.12 5 63
5 13 849.88 20 14.78 1572 465 4.17 / 370.58 5 75
6 13 415.32 20 14.90 964 287 4.46 / 370.87 5 77
7 8 -0.08 361 14.96 322 1739 6.20 / 372.61 5 132
Average= 9.32
(KJ/cycle)

Cycle 63 GMT 12/ 9/2023 21:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.56 39 14.96 449 262 0.26 / 360.59 5 22
2 7 2005.52 40 14.67 3090 1813 2.08 / 362.40 22 53
3 13 1920.68 20 14.66 2985 875 2.95 / 363.28 5 55
4 13 1499.88 20 14.66 2445 717 3.67 / 364.00 5 63
5 13 952.88 20 14.75 1708 504 4.17 / 364.50 5 72
6 13 396.80 20 14.91 932 278 4.45 / 364.78 5 77
7 8 0.04 353 14.97 309 1633 6.08 / 366.41 5 141
Average= 9.40
(KJ/cycle)

Cycle 62 GMT 3/ 9/2023 0:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 39 14.96 459 268 0.27 / 354.62 5 22
2 7 2006.00 40 14.67 3085 1810 2.08 / 356.43 22 54
3 13 1912.68 20 14.66 2969 871 2.95 / 357.30 5 57
4 13 1485.88 20 14.67 2412 708 3.66 / 358.01 5 65
5 13 935.80 20 14.76 1687 498 4.15 / 358.51 5 73
6 13 284.00 20 14.96 765 229 4.38 / 358.74 5 74
7 13 51.32 20 15.03 404 121 4.50 / 358.86 5 61
8 8 0.00 319 14.98 308 1472 5.98 / 360.33 5 137
Average= 9.48
(KJ/cycle)

Cycle 61 GMT 24/ 8/2023 3:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 39 14.96 453 264 0.26 / 348.79 5 21
2 7 2011.04 40 14.68 3095 1817 2.08 / 350.61 21 52
3 13 1924.76 20 14.66 2986 875 2.96 / 351.48 5 55
4 13 1404.12 20 14.69 2312 679 3.64 / 352.16 5 66
5 13 882.68 20 14.78 1612 477 4.11 / 352.64 5 73
6 13 142.56 20 15.02 547 164 4.28 / 352.80 5 67
7 8 0.04 338 14.99 306 1550 5.83 / 354.35 5 137
Average= 9.58
(KJ/cycle)

Cycle 60 GMT 14/ 8/2023 6:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 39 14.96 460 268 0.27 / 342.69 5 21
2 7 2009.08 40 14.69 3087 1814 2.08 / 344.50 21 52
3 13 1912.52 20 14.67 2967 871 2.95 / 345.37 5 56
4 13 1590.44 20 14.66 2552 748 3.70 / 346.12 5 62
5 13 933.40 20 14.77 1675 495 4.20 / 346.62 5 73
6 13 398.48 20 14.93 930 278 4.47 / 346.90 5 77
7 8 0.04 351 14.98 310 1630 6.10 / 348.53 5 137
Average= 9.68
(KJ/cycle)

Cycle 59 GMT 4/ 8/2023 9:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.68 39 14.96 457 267 0.27 / 336.58 5 19
2 7 2013.40 40 14.69 3091 1816 2.08 / 338.40 19 53
3 13 1931.24 20 14.67 3001 880 2.96 / 339.28 5 56
4 13 1524.36 20 14.67 2463 723 3.69 / 340.00 5 64
5 13 893.80 20 14.78 1622 479 4.17 / 340.48 5 73
6 13 454.36 20 14.90 1013 302 4.47 / 340.78 5 77
7 8 0.00 355 14.99 308 1639 6.11 / 342.42 5 132
Average= 9.78
(KJ/cycle)

Cycle 58 GMT 25/ 7/2023 12:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 39 14.98 454 265 0.27 / 330.56 5 20
2 7 2004.76 40 14.68 3087 1813 2.08 / 332.38 20 53
3 13 1914.40 20 14.67 2978 874 2.95 / 333.25 5 57
4 13 1396.72 20 14.70 2296 675 3.63 / 333.93 5 65
5 13 970.20 20 14.76 1729 510 4.14 / 334.44 5 72
6 13 306.32 20 14.96 801 240 4.38 / 334.68 5 74
7 8 -0.08 344 14.99 318 1640 6.02 / 336.32 5 147
Average= 9.89
(KJ/cycle)

Cycle 57 GMT 15/ 7/2023 15:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 39 14.98 439 256 0.26 / 324.54 5 18
2 7 2005.36 40 14.69 3084 1812 2.07 / 326.35 18 53
3 13 1917.88 20 14.67 2975 873 2.94 / 327.23 5 56
4 13 1491.88 20 14.68 2425 712 3.65 / 327.94 5 64
5 13 927.16 20 14.78 1679 496 4.15 / 328.44 5 72
6 13 371.40 20 14.95 891 266 4.42 / 328.70 5 75
7 8 0.12 340 15.00 313 1596 6.01 / 330.30 5 137
Average= 10.01
(KJ/cycle)

Cycle 56 GMT 5/ 7/2023 18:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 39 14.98 452 264 0.26 / 318.62 5 17
2 7 2015.04 40 14.69 3094 1818 2.08 / 320.44 17 52
3 13 1934.40 20 14.67 2998 880 2.96 / 321.32 5 56
4 13 1422.12 20 14.70 2335 686 3.65 / 322.01 5 65
5 13 897.28 20 14.80 1632 483 4.13 / 322.49 5 73
6 13 268.12 20 14.99 737 221 4.35 / 322.71 5 72
7 8 -0.04 342 15.01 307 1576 5.93 / 324.29 5 136
Average= 10.13
(KJ/cycle)

Cycle 55 GMT 25/ 6/2023 21:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 39 14.98 456 266 0.27 / 312.54 5 17
2 7 2006.08 41 14.69 3091 1862 2.13 / 314.40 17 54
3 13 1920.40 20 14.67 2997 879 3.01 / 315.28 5 56
4 13 1498.12 20 14.69 2427 713 3.72 / 315.99 5 64
5 13 844.40 20 14.81 1562 463 4.18 / 316.45 5 74
6 13 413.28 20 14.93 958 286 4.47 / 316.74 5 76
7 13 32.76 20 15.06 374 113 4.58 / 316.85 5 59
8 8 0.00 325 15.00 309 1506 6.09 / 318.36 5 145
Average= 10.27
(KJ/cycle)

Cycle 54 GMT 16/ 6/2023 0:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 39 14.99 457 267 0.27 / 306.52 5 17
2 7 2004.36 41 14.69 3097 1865 2.13 / 308.39 17 54
3 13 1910.64 20 14.68 2979 875 3.01 / 309.26 5 57
4 13 1388.24 20 14.72 2285 673 3.68 / 309.94 5 65
5 13 873.36 20 14.81 1600 474 4.15 / 310.41 5 74
6 13 337.44 20 14.97 846 253 4.41 / 310.66 5 75
7 8 0.08 344 15.01 311 1606 6.01 / 312.27 5 131
Average= 10.41
(KJ/cycle)

Cycle 53 GMT 6/ 6/2023 3:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 39 15.00 451 264 0.26 / 300.49 5 16
2 7 2010.08 40 14.70 3091 1818 2.08 / 302.30 16 53
3 13 1920.64 20 14.68 2987 877 2.96 / 303.18 5 57
4 13 1407.32 20 14.72 2313 681 3.64 / 303.86 5 65
5 13 977.92 20 14.78 1748 517 4.16 / 304.38 5 72
6 13 422.92 20 14.94 972 290 4.45 / 304.67 5 78
7 13 19.56 20 15.08 357 108 4.55 / 304.78 5 53
8 8 -0.08 319 15.01 309 1480 6.03 / 306.26 5 135
Average= 10.56
(KJ/cycle)

Cycle 52 GMT 27/ 5/2023 6:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 39 15.00 450 263 0.26 / 294.42 5 15
2 7 2013.96 40 14.69 3110 1827 2.09 / 296.25 15 52
3 13 1928.00 20 14.67 3004 881 2.97 / 297.13 5 56
4 13 1728.88 20 14.64 2741 803 3.77 / 297.93 5 61
5 13 926.84 20 14.81 1676 496 4.27 / 298.43 5 73
6 13 282.24 20 15.00 771 231 4.50 / 298.66 5 74
7 8 -0.04 336 15.02 310 1564 6.07 / 300.22 5 139
Average= 10.72
(KJ/cycle)

Cycle 51 GMT 17/ 5/2023 9:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.60 39 15.00 446 261 0.26 / 288.54 5 15
2 7 2008.52 40 14.70 3083 1813 2.07 / 290.35 15 52
3 13 1915.32 20 14.69 2975 874 2.95 / 291.23 5 57
4 13 1284.68 20 14.75 2157 636 3.58 / 291.86 5 66
5 13 856.20 20 14.82 1585 470 4.05 / 292.33 5 74
6 13 300.44 20 14.99 798 239 4.29 / 292.57 5 75
7 8 -0.08 338 15.02 312 1584 5.88 / 294.16 5 130
Average= 10.89
(KJ/cycle)

Cycle 50 GMT 7/ 5/2023 12:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 39 15.02 440 258 0.26 / 282.51 5 14
2 7 2013.20 41 14.70 3092 1864 2.12 / 284.38 14 52
3 13 1922.32 20 14.68 2984 876 3.00 / 285.25 5 57
4 13 1506.12 20 14.70 2447 719 3.72 / 285.97 5 64
5 13 849.96 20 14.83 1567 465 4.18 / 286.44 5 74
6 13 322.80 20 14.99 826 248 4.43 / 286.68 5 75
7 8 0.08 336 15.03 316 1596 6.03 / 288.28 5 135
Average= 11.09
(KJ/cycle)

Cycle 49 GMT 27/ 4/2023 15:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.44 39 15.01 436 255 0.26 / 276.54 5 15
2 7 2005.76 41 14.71 3080 1858 2.11 / 278.40 15 53
3 13 1920.04 20 14.69 2979 875 2.99 / 279.28 5 56
4 13 1486.56 20 14.71 2410 709 3.70 / 279.99 5 64
5 13 938.24 20 14.81 1684 499 4.20 / 280.48 5 73
6 13 289.12 20 15.01 777 233 4.43 / 280.72 5 74
7 8 0.12 336 15.04 304 1536 5.97 / 282.25 5 137
Average= 11.29
(KJ/cycle)

Cycle 48 GMT 17/ 4/2023 18:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 39 15.03 435 255 0.25 / 270.49 5 14
2 7 2004.24 41 14.70 3086 1860 2.11 / 272.35 14 52
3 13 1910.00 20 14.69 2972 873 2.99 / 273.22 5 57
4 13 1495.76 20 14.71 2426 714 3.70 / 273.94 5 63
5 13 949.84 20 14.81 1704 505 4.21 / 274.44 5 72
6 13 285.76 20 15.01 774 232 4.44 / 274.68 5 75
7 13 32.20 20 15.10 375 113 4.55 / 274.79 5 58
8 8 -0.16 321 15.03 311 1500 6.05 / 276.29 5 136
Average= 11.51
(KJ/cycle)

Cycle 47 GMT 7/ 4/2023 21:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 39 15.03 442 259 0.26 / 264.64 5 14
2 7 2005.52 41 14.70 3093 1864 2.12 / 266.50 14 53
3 13 1920.84 20 14.69 2978 875 3.00 / 267.38 5 56
4 13 1385.16 20 14.74 2282 673 3.67 / 268.05 5 65
5 13 855.84 20 14.85 1573 467 4.14 / 268.52 5 74
6 13 209.44 20 15.05 651 196 4.33 / 268.71 5 71
7 8 -0.08 332 15.05 305 1524 5.86 / 270.24 5 132
Average= 11.75
(KJ/cycle)

Cycle 46 GMT 29/ 3/2023 0:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 39 15.03 459 269 0.27 / 258.66 5 13
2 7 2012.12 40 14.71 3093 1820 2.09 / 260.48 13 53
3 13 1919.64 20 14.70 2983 877 2.97 / 261.35 5 56
4 13 1502.00 20 14.72 2436 717 3.68 / 262.07 5 64
5 13 962.72 20 14.82 1715 508 4.19 / 262.58 5 73
6 13 314.56 20 15.01 811 243 4.43 / 262.82 5 75
7 8 0.04 338 15.05 306 1557 5.99 / 264.38 5 144
Average= 12.02
(KJ/cycle)

Cycle 45 GMT 19/ 3/2023 3:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 39 15.04 450 264 0.26 / 252.55 5 13
2 7 2006.48 40 14.71 3082 1813 2.08 / 254.37 13 53
3 13 1924.72 20 14.70 2982 877 2.95 / 255.24 5 57
4 13 1499.72 20 14.72 2434 717 3.67 / 255.96 5 64
5 13 1051.08 20 14.80 1833 543 4.21 / 256.50 5 71
6 13 381.84 20 14.98 916 274 4.49 / 256.78 5 76
7 13 28.72 20 15.10 373 113 4.60 / 256.89 5 57
8 8 -0.16 319 15.04 312 1497 6.10 / 258.39 5 134
Average= 12.30
(KJ/cycle)

Cycle 44 GMT 9/ 3/2023 6:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.12 39 15.04 440 258 0.26 / 246.53 5 13
2 7 2005.84 40 14.72 3088 1818 2.08 / 248.35 13 54
3 13 1914.72 20 14.70 2980 876 2.95 / 249.23 5 57
4 13 1493.92 20 14.73 2420 713 3.67 / 249.94 5 64
5 13 951.04 20 14.82 1706 506 4.17 / 250.44 5 73
6 13 402.40 20 14.99 934 280 4.45 / 250.72 5 76
7 13 35.56 20 15.11 377 114 4.56 / 250.84 5 58
8 8 -0.12 314 15.05 307 1451 6.02 / 252.29 5 135
Average= 12.61
(KJ/cycle)

Cycle 43 GMT 27/ 2/2023 9: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 39 15.05 433 254 0.25 / 240.56 5 14
2 7 2012.40 40 14.71 3104 1826 2.08 / 242.39 14 54
3 13 1926.36 20 14.70 2995 881 2.96 / 243.27 5 56
4 13 1505.76 20 14.73 2445 720 3.68 / 243.99 5 64
5 13 865.60 20 14.85 1593 473 4.15 / 244.46 5 75
6 13 322.76 20 15.01 826 248 4.40 / 244.71 5 76
7 13 19.84 20 15.12 351 106 4.51 / 244.82 5 54
8 8 -0.12 313 15.05 309 1456 5.96 / 246.27 5 142
Average= 12.96
(KJ/cycle)

Cycle 42 GMT 17/ 2/2023 12:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.44 39 15.04 441 259 0.26 / 234.67 5 13
2 7 2004.04 41 14.71 3086 1861 2.12 / 236.53 13 53
3 13 1913.52 20 14.70 2971 873 2.99 / 237.40 5 56
4 13 1397.00 20 14.76 2294 677 3.67 / 238.08 5 65
5 13 866.08 20 14.86 1590 473 4.14 / 238.55 5 75
6 13 230.08 20 15.06 687 207 4.35 / 238.76 5 72
7 13 25.96 20 15.12 361 109 4.46 / 238.87 5 55
8 8 0.08 312 15.06 307 1443 5.90 / 240.31 5 143
Average= 13.35
(KJ/cycle)

Cycle 41 GMT 7/ 2/2023 14:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.92 39 15.04 438 257 0.26 / 228.67 5 14
2 7 2005.68 41 14.71 3089 1863 2.12 / 230.53 14 53
3 13 1916.24 20 14.71 2981 877 3.00 / 231.41 5 58
4 13 1483.96 20 14.74 2420 713 3.71 / 232.12 5 64
5 13 925.20 20 14.85 1670 496 4.21 / 232.62 5 73
6 13 257.00 20 15.05 729 219 4.43 / 232.84 5 74
7 13 27.52 20 15.12 365 110 4.54 / 232.95 5 56
8 8 -0.12 314 15.06 309 1461 6.00 / 234.41 5 131
Average= 13.79
(KJ/cycle)

Cycle 40 GMT 28/ 1/2023 18: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 39 15.05 452 265 0.27 / 222.45 5 14
2 7 2004.32 40 14.72 3088 1818 2.08 / 224.27 14 53
3 13 1914.40 20 14.70 2983 877 2.96 / 225.14 5 56
4 13 1599.40 20 14.71 2557 752 3.71 / 225.89 5 63
5 13 1147.00 20 14.78 1966 581 4.29 / 226.48 5 71
6 13 443.52 20 14.98 1001 300 4.59 / 226.78 5 77
7 13 39.32 20 15.11 391 118 4.71 / 226.89 5 60
8 8 -0.12 321 15.05 314 1517 6.23 / 228.41 5 129
Average= 14.28
(KJ/cycle)

Cycle 39 GMT 18/ 1/2023 21:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 39 15.05 453 266 0.27 / 216.41 5 14
2 7 2007.48 40 14.73 3093 1822 2.09 / 218.23 14 53
3 13 1929.68 20 14.71 3001 883 2.97 / 219.12 5 56
4 13 1397.80 20 14.77 2301 680 3.65 / 219.80 5 65
5 13 891.00 20 14.86 1625 483 4.13 / 220.28 5 74
6 13 452.40 20 14.98 1014 304 4.44 / 220.58 5 78
7 8 0.00 338 15.07 314 1599 6.04 / 222.18 5 147
Average= 14.81
(KJ/cycle)

Cycle 38 GMT 9/ 1/2023 0: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 39 15.06 459 270 0.27 / 210.43 5 16
2 7 2007.84 40 14.73 3090 1821 2.09 / 212.25 16 54
3 13 1909.64 20 14.72 2969 874 2.96 / 213.13 5 57
4 13 1474.08 20 14.76 2401 709 3.67 / 213.84 5 64
5 13 832.68 20 14.89 1545 460 4.13 / 214.30 5 75
6 13 300.44 20 15.04 794 239 4.37 / 214.53 5 75
7 8 0.00 336 15.07 318 1610 5.98 / 216.14 5 137
Average= 15.44
(KJ/cycle)

Cycle 37 GMT 30/12/2022 3: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 39 15.05 455 267 0.27 / 204.44 5 17
2 7 2006.64 40 14.73 3097 1825 2.09 / 206.26 17 53
3 13 1919.76 20 14.72 2976 876 2.97 / 207.14 5 56
4 13 1471.72 20 14.76 2398 708 3.68 / 207.84 5 64
5 13 936.04 20 14.86 1686 501 4.18 / 208.35 5 73
6 13 296.40 20 15.05 785 236 4.41 / 208.58 5 74
7 13 18.32 20 15.14 355 107 4.52 / 208.69 5 51
8 8 -0.08 314 15.08 311 1473 5.99 / 210.16 5 135
Average= 16.17
(KJ/cycle)

Cycle 36 GMT 20/12/2022 6:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.12 39 15.06 465 273 0.27 / 198.40 5 18
2 7 2015.76 40 14.73 3108 1831 2.10 / 200.23 18 53
3 13 1937.84 20 14.72 2998 883 2.99 / 201.12 5 56
4 13 1309.16 20 14.80 2184 646 3.63 / 201.76 5 67
5 13 810.72 20 14.90 1515 451 4.08 / 202.21 5 75
6 13 482.32 20 14.98 1052 315 4.40 / 202.53 5 77
7 8 -0.04 349 15.07 312 1641 6.04 / 204.17 5 149
Average= 17.01
(KJ/cycle)

Cycle 35 GMT 10/12/2022 8:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 39 15.05 469 275 0.28 / 192.33 5 18
2 7 2003.40 41 14.73 3084 1863 2.14 / 194.20 18 52
3 13 1910.28 20 14.72 2971 875 3.01 / 195.07 5 57
4 13 1387.68 20 14.78 2288 676 3.69 / 195.75 5 66
5 13 1079.60 20 14.82 1878 557 4.25 / 196.30 5 72
6 13 197.60 20 15.09 634 191 4.44 / 196.50 5 71
7 13 40.00 20 15.14 386 117 4.55 / 196.61 5 59
8 8 0.00 319 15.08 315 1515 6.07 / 198.13 5 134
Average= 18.01
(KJ/cycle)

Cycle 34 GMT 30/11/2022 11:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 39 15.07 461 271 0.27 / 186.16 5 18
2 7 2012.56 41 14.73 3097 1870 2.14 / 188.03 25 52
3 13 1924.12 20 14.72 3004 884 3.03 / 188.92 5 57
4 13 1394.44 20 14.79 2291 678 3.70 / 189.59 5 65
5 13 977.88 20 14.85 1742 517 4.22 / 190.11 5 73
6 13 411.00 20 15.02 954 287 4.51 / 190.40 5 75
7 13 30.28 20 15.14 377 114 4.62 / 190.51 5 56
8 8 -0.12 321 15.07 320 1548 6.17 / 192.06 5 132
Average= 19.21
(KJ/cycle)

Cycle 33 GMT 20/11/2022 14:37: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.96 39 15.06 478 281 0.28 / 180.22 5 19
2 7 2006.00 40 14.74 3097 1826 2.11 / 182.05 19 52
3 13 1922.28 20 14.73 2987 880 2.99 / 182.93 5 56
4 13 1504.32 20 14.76 2443 721 3.71 / 183.65 5 64
5 13 862.52 20 14.90 1583 472 4.18 / 184.12 5 74
6 13 228.96 20 15.09 682 206 4.39 / 184.33 5 69
7 8 0.00 332 15.10 312 1564 5.95 / 185.89 5 144
Average= 20.65
(KJ/cycle)

Cycle 32 GMT 10/11/2022 17:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.40 39 15.06 455 267 0.27 / 174.16 5 21
2 7 2007.20 40 14.75 3094 1825 2.09 / 175.99 21 53
3 13 1921.32 20 14.73 2986 880 2.97 / 176.87 5 56
4 13 1393.16 20 14.80 2291 678 3.65 / 177.55 5 65
5 13 956.12 20 14.87 1711 509 4.16 / 178.05 5 72
6 13 290.56 20 15.07 778 234 4.39 / 178.29 5 73
7 8 -0.08 342 15.09 320 1651 6.05 / 179.94 5 132
Average= 22.49
(KJ/cycle)

Cycle 31 GMT 31/10/2022 20:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.44 38 15.07 460 263 0.26 / 167.99 5 21
2 7 2005.24 40 14.75 3093 1825 2.09 / 169.81 21 53
3 13 1913.40 20 14.75 2980 879 2.97 / 170.69 5 56
4 13 1398.56 20 14.79 2305 682 3.65 / 171.38 5 65
5 13 981.04 20 14.87 1745 519 4.17 / 171.89 5 72
6 13 432.56 20 15.02 991 298 4.47 / 172.19 5 76
7 8 -0.08 357 15.09 316 1702 6.17 / 173.89 5 132
Average= 24.84
(KJ/cycle)

Cycle 30 GMT 21/10/2022 23:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 38 15.07 462 265 0.26 / 161.80 5 22
2 7 2011.32 40 14.75 3103 1831 2.10 / 163.63 22 53
3 13 1928.36 20 14.74 2999 884 2.98 / 164.51 5 57
4 13 1502.84 20 14.77 2449 723 3.70 / 165.24 5 65
5 13 956.52 20 14.88 1708 508 4.21 / 165.74 5 73
6 13 415.68 20 15.03 966 290 4.50 / 166.03 5 76
7 8 0.08 355 15.09 316 1693 6.19 / 167.73 5 129
Average= 27.95
(KJ/cycle)

Cycle 29 GMT 12/10/2022 2:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 38 15.08 467 268 0.27 / 155.72 5 22
2 7 2011.32 41 14.74 3106 1877 2.14 / 157.60 22 53
3 13 1928.56 20 14.74 3000 884 3.03 / 158.48 5 57
4 13 1399.00 20 14.80 2304 682 3.71 / 159.16 5 66
5 13 967.16 20 14.88 1732 515 4.23 / 159.68 5 73
6 13 212.68 20 15.11 664 201 4.43 / 159.88 5 71
7 8 -0.08 349 15.10 314 1655 6.08 / 161.53 5 136
Average= 32.31
(KJ/cycle)

Cycle 28 GMT 2/10/2022 5:21: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 38 15.07 465 266 0.27 / 149.66 5 24
2 7 2004.08 41 14.75 3091 1869 2.14 / 151.53 24 54
3 13 1908.56 20 14.74 2980 879 3.01 / 152.41 5 57
4 13 1385.52 20 14.81 2294 679 3.69 / 153.08 5 67
5 13 846.72 20 14.92 1576 470 4.16 / 153.55 5 75
6 13 209.12 20 15.12 659 199 4.36 / 153.75 5 72
7 8 -0.04 353 15.11 318 1696 6.06 / 155.45 5 142
Average= 38.86
(KJ/cycle)

Cycle 27 GMT 22/ 9/2022 8:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.20 38 15.08 487 279 0.28 / 143.41 5 23
2 7 2006.36 41 14.75 3095 1872 2.15 / 145.28 23 53
3 13 1916.80 20 14.74 2979 878 3.03 / 146.16 5 57
4 13 1386.52 20 14.82 2283 677 3.71 / 146.83 5 66
5 13 958.92 20 14.88 1721 512 4.22 / 147.34 5 73
6 13 385.20 20 15.05 920 277 4.49 / 147.62 5 78
7 8 -0.08 364 15.10 322 1770 6.26 / 149.39 5 140
Average= 49.80
(KJ/cycle)

Cycle 26 GMT 12/ 9/2022 11:14: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 38 15.08 466 267 0.27 / 137.11 5 23
2 7 2015.44 41 14.75 3110 1881 2.15 / 138.99 9 53
3 13 1923.80 20 14.75 2996 884 3.03 / 139.88 5 57
4 13 1608.80 20 14.76 2578 761 3.79 / 140.64 5 63
5 13 1032.44 20 14.87 1818 541 4.33 / 141.18 5 72
6 13 259.12 20 15.10 740 223 4.56 / 141.40 5 74
7 8 0.04 357 15.11 320 1726 6.28 / 143.13 5 134
Average= 71.56
(KJ/cycle)

Cycle 25 GMT 2/ 9/2022 14:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.84 38 15.08 476 273 0.27 / 130.98 5 22
2 7 2017.20 40 14.76 3107 1834 2.11 / 132.81 22 53
3 13 1932.20 20 14.76 3003 886 2.99 / 133.70 5 56
4 13 1400.28 20 14.82 2303 683 3.68 / 134.38 5 66
5 13 869.48 20 14.92 1594 476 4.15 / 134.86 5 75
6 13 303.60 20 15.08 803 242 4.39 / 135.10 5 76
7 8 0.08 364 15.11 317 1744 6.14 / 136.84 5 134
Average= 136.84
(KJ/cycle)

Cycle 23 GMT 13/ 8/2022 20:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.40 38 15.10 453 260 0.26 / 124.96 5 25
2 7 2010.56 40 14.76 3097 1828 2.09 / 126.79 25 54
3 13 1917.28 20 14.77 2988 883 2.97 / 127.67 5 57
4 13 1482.60 20 14.81 2414 715 3.69 / 128.39 5 65
5 13 837.72 20 14.94 1554 464 4.15 / 128.85 5 75
6 13 195.36 20 15.14 641 194 4.34 / 129.04 5 73
7 8 0.08 351 15.13 313 1662 6.01 / 130.71 5 138
Average= 26.14
(KJ/cycle)

Cycle 22 GMT 3/ 8/2022 23:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 38 15.08 484 277 0.28 / 118.86 5 24
2 7 2004.88 40 14.77 3089 1825 2.10 / 120.69 24 54
3 13 1915.80 20 14.77 2985 882 2.98 / 121.57 5 58
4 13 1398.16 20 14.83 2300 682 3.67 / 122.25 5 66
5 13 964.76 20 14.90 1730 516 4.18 / 122.77 5 73
6 13 189.36 20 15.14 633 192 4.37 / 122.96 5 72
7 8 0.00 359 15.12 321 1742 6.12 / 124.70 5 143
Average= 31.17
(KJ/cycle)

Cycle 21 GMT 25/ 7/2022 2: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 38 15.10 467 268 0.27 / 112.48 5 22
2 7 2005.96 40 14.78 3093 1829 2.10 / 114.31 22 53
3 13 1917.64 20 14.77 2986 882 2.98 / 115.19 5 57
4 13 1488.40 20 14.81 2426 719 3.70 / 115.91 5 65
5 13 943.36 20 14.92 1695 506 4.20 / 116.41 5 73
6 13 602.92 20 14.99 1225 367 4.57 / 116.78 5 78
7 8 -0.04 366 15.12 326 1804 6.37 / 118.58 5 134
Average= 39.53
(KJ/cycle)

Cycle 20 GMT 15/ 7/2022 5:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 38 15.11 485 278 0.28 / 106.38 5 21
2 7 2003.36 40 14.79 3088 1827 2.11 / 108.21 21 53
3 13 1811.04 20 14.80 2845 842 2.95 / 109.05 5 58
4 13 1411.80 20 14.83 2324 689 3.64 / 109.74 5 66
5 13 973.16 20 14.91 1743 520 4.16 / 110.26 5 72
6 13 303.32 20 15.11 797 241 4.40 / 110.50 5 74
7 8 0.00 355 15.13 318 1708 6.11 / 112.21 5 136
Average= 56.10
(KJ/cycle)

Cycle 19 GMT 5/ 7/2022 8:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 38 15.13 468 269 0.27 / 100.24 5 21
2 7 2004.88 40 14.78 3096 1830 2.10 / 102.07 21 53
3 13 1914.00 20 14.78 2979 881 2.98 / 102.95 5 57
4 13 1500.52 20 14.82 2445 725 3.70 / 103.68 5 65
5 13 851.32 20 14.95 1577 472 4.18 / 104.15 5 75
6 13 401.80 20 15.07 946 285 4.46 / 104.43 5 77
7 8 0.00 346 15.14 319 1671 6.13 / 106.10 5 132
Average= 106.10
(KJ/cycle)

Cycle 17 GMT 15/ 6/2022 14:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 38 15.12 472 271 0.27 / 94.29 5 20
2 7 2010.00 40 14.78 3110 1839 2.11 / 96.13 20 53
3 13 1928.96 20 14.79 3011 891 3.00 / 97.02 5 57
4 13 1296.56 20 14.87 2172 646 3.65 / 97.66 5 67
5 13 873.68 20 14.95 1606 480 4.13 / 98.14 5 75
6 13 116.88 20 15.18 523 159 4.29 / 98.30 5 70
7 8 0.04 342 15.15 322 1668 5.95 / 99.97 5 140
Average= 5.55
(KJ/cycle)

Cycle 16 GMT 5/ 6/2022 16:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 38 15.11 479 275 0.28 / 88.07 5 19
2 7 2006.68 40 14.79 3102 1835 2.11 / 89.90 19 53
3 13 1920.28 20 14.79 2998 887 3.00 / 90.79 5 57
4 13 1295.96 20 14.88 2165 644 3.64 / 91.43 5 67
5 13 870.76 20 14.96 1596 478 4.12 / 91.91 5 74
6 13 524.88 20 15.04 1124 338 4.46 / 92.25 5 80
7 8 -0.12 355 15.14 329 1768 6.23 / 94.02 5 131
Average= 5.53
(KJ/cycle)

Cycle 15 GMT 26/ 5/2022 20: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 38 15.13 462 266 0.27 / 81.73 5 18
2 7 2010.68 40 14.79 3108 1839 2.10 / 83.57 18 53
3 13 1924.20 20 14.79 2999 887 2.99 / 84.46 5 57
4 13 1615.64 20 14.80 2591 767 3.76 / 85.22 5 63
5 13 1022.88 20 14.91 1807 539 4.30 / 85.76 5 73
6 13 338.24 20 15.11 861 260 4.56 / 86.02 5 79
7 8 -0.04 351 15.14 333 1770 6.33 / 87.79 5 135
Average= 5.49
(KJ/cycle)

Cycle 14 GMT 16/ 5/2022 23:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.72 38 15.13 456 262 0.26 / 75.52 5 16
2 7 2004.40 40 14.80 3095 1832 2.09 / 77.36 16 53
3 13 1925.04 20 14.80 3000 888 2.98 / 78.24 5 57
4 13 1504.00 20 14.84 2451 727 3.71 / 78.97 5 65
5 13 1064.00 20 14.91 1858 554 4.26 / 79.53 5 72
6 13 261.48 20 15.14 746 226 4.49 / 79.75 5 77
7 8 -0.12 359 15.15 315 1713 6.20 / 81.47 5 140
Average= 5.43
(KJ/cycle)

Cycle 13 GMT 7/ 5/2022 2:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 38 15.14 461 265 0.27 / 69.36 5 17
2 7 2004.60 40 14.81 3094 1833 2.10 / 71.20 17 53
3 13 1913.56 20 14.81 2981 883 2.98 / 72.08 5 57
4 13 1504.00 20 14.84 2441 724 3.71 / 72.80 5 65
5 13 1043.20 20 14.92 1834 547 4.25 / 73.35 5 73
6 13 159.76 20 15.18 591 179 4.43 / 73.53 5 75
7 8 0.00 353 15.15 324 1733 6.16 / 75.26 5 132
Average= 5.38
(KJ/cycle)

Cycle 12 GMT 27/ 4/2022 5:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 38 15.14 452 260 0.26 / 63.29 5 16
2 7 2010.08 40 14.81 3094 1833 2.09 / 65.12 16 53
3 13 1918.56 20 14.81 2981 883 2.98 / 66.00 5 57
4 13 1381.48 20 14.87 2287 680 3.66 / 66.68 5 67
5 13 831.60 20 14.98 1543 462 4.12 / 67.14 5 74
6 13 272.24 20 15.14 760 230 4.35 / 67.37 5 77
7 8 -0.04 353 15.16 322 1723 6.07 / 69.10 5 144
Average= 5.32
(KJ/cycle)

Cycle 11 GMT 17/ 4/2022 8:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 38 15.14 452 260 0.26 / 57.17 5 14
2 7 2009.08 40 14.82 3099 1837 2.10 / 59.00 14 54
3 13 1930.52 20 14.81 2995 887 2.98 / 59.89 5 57
4 13 1509.96 20 14.85 2444 726 3.71 / 60.62 5 65
5 13 959.48 20 14.95 1721 515 4.22 / 61.13 5 73
6 13 197.28 20 15.17 642 195 4.42 / 61.32 5 75
7 8 -0.24 355 15.16 316 1701 6.12 / 63.03 5 139
Average= 5.25
(KJ/cycle)

Cycle 10 GMT 7/ 4/2022 11: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.88 38 15.15 456 263 0.26 / 51.10 5 13
2 7 2006.84 40 14.82 3088 1831 2.09 / 52.93 13 53
3 13 1924.00 20 14.82 2979 883 2.98 / 53.81 5 57
4 13 1484.16 20 14.86 2420 719 3.70 / 54.53 5 65
5 13 1060.52 20 14.92 1849 552 4.25 / 55.09 5 72
6 13 169.40 20 15.19 597 181 4.43 / 55.27 5 72
7 8 -0.12 344 15.17 314 1639 6.07 / 56.91 5 132
Average= 5.17
(KJ/cycle)

Cycle 9 GMT 28/ 3/2022 14: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 38 15.16 440 253 0.25 / 45.16 5 13
2 7 2007.68 40 14.83 3090 1833 2.09 / 46.99 13 52
3 13 1928.92 20 14.82 2997 888 2.97 / 47.88 5 57
4 13 1380.32 20 14.88 2275 677 3.65 / 48.56 5 66
5 13 742.28 20 15.02 1422 427 4.08 / 48.99 5 75
6 13 204.84 20 15.18 655 199 4.28 / 49.18 5 72
7 8 -0.28 346 15.17 315 1653 5.93 / 50.84 5 143
Average= 5.08
(KJ/cycle)

Cycle 8 GMT 18/ 3/2022 17: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.80 37 15.15 429 240 0.24 / 39.15 5 13
2 7 2005.64 41 14.83 3091 1879 2.12 / 41.03 5 53
3 13 1920.20 20 14.82 2978 883 3.00 / 41.92 5 57
4 13 1397.88 20 14.88 2292 682 3.68 / 42.60 5 65
5 13 849.60 20 14.99 1573 472 4.16 / 43.07 5 74
6 13 200.72 20 15.18 648 197 4.35 / 43.27 5 72
7 8 -0.08 340 15.18 318 1641 5.99 / 44.91 5 135
Average= 4.99
(KJ/cycle)

Cycle 7 GMT 8/ 3/2022 19:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.48 37 15.15 454 254 0.25 / 33.10 5 12
2 7 2007.40 41 14.83 3093 1881 2.14 / 34.98 12 53
3 13 1915.84 20 14.83 2981 884 3.02 / 35.86 5 57
4 13 1481.04 20 14.87 2403 715 3.73 / 36.58 5 64
5 13 836.52 20 15.00 1553 466 4.20 / 37.04 5 74
6 13 186.08 20 15.19 630 191 4.39 / 37.24 5 73
7 13 35.80 20 15.23 389 118 4.51 / 37.35 5 58
8 8 -0.16 321 15.17 320 1558 6.07 / 38.91 5 169
Average= 4.86
(KJ/cycle)

Cycle 6 GMT 26/ 2/2022 22:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 36 15.15 466 254 0.25 / 27.17 5 13
2 3 1048.36 1 15.16 1855 28 0.28 / 27.20 5 30
3 7 2005.92 40 14.84 3086 1832 2.11 / 29.03 30 53
4 13 1917.16 20 14.83 2982 884 3.00 / 29.92 5 57
5 13 1304.48 20 14.91 2172 648 3.65 / 30.57 5 67
6 13 788.12 20 15.01 1488 447 4.09 / 31.01 5 74
7 13 140.32 20 15.21 562 171 4.26 / 31.18 5 71
8 8 -0.20 342 15.17 320 1660 5.92 / 32.84 5 136
Average= 4.69
(KJ/cycle)

Cycle 5 GMT 17/ 2/2022 1:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 31 15.16 458 215 0.22 / 20.96 5 13
2 10 1018.76 4 15.11 1785 108 0.32 / 21.07 5 46
3 3 1070.40 2 15.15 1875 57 0.38 / 21.13 5 37
4 7 2004.84 40 14.84 3094 1837 2.22 / 22.96 37 52
5 13 1913.04 20 14.84 2981 885 3.10 / 23.85 5 57
6 13 1486.56 20 14.87 2427 722 3.82 / 24.57 5 64
7 13 1022.80 20 14.95 1803 539 4.36 / 25.11 5 72
8 13 136.84 20 15.21 552 168 4.53 / 25.28 5 70
9 13 25.88 20 15.24 368 112 4.64 / 25.39 5 55
10 8 -0.12 321 15.18 314 1530 6.17 / 26.92 5 143
Average= 4.49
(KJ/cycle)

Cycle 4 GMT 7/ 2/2022 4:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 36 15.15 461 251 0.25 / 15.76 5 13
2 7 1516.80 40 15.00 2428 1457 1.71 / 17.22 13 57
3 13 1456.04 20 14.99 2352 705 2.41 / 17.93 5 60
4 13 1165.96 20 15.00 1960 588 3.00 / 18.51 5 66
5 13 839.36 20 15.03 1533 461 3.46 / 18.97 5 73
6 13 71.68 20 15.25 438 134 3.60 / 19.11 5 63
7 8 -0.12 345 15.19 313 1640 5.24 / 20.75 5 156
Average= 4.15
(KJ/cycle)

Cycle 3 GMT 5/ 2/2022 18:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 36 15.15 459 250 0.25 / 10.55 5 13
2 7 1518.56 40 14.99 2440 1463 1.71 / 12.01 5 57
3 13 1458.08 20 14.98 2370 710 2.42 / 12.72 5 61
4 13 1160.72 20 14.99 1975 592 3.02 / 13.31 5 67
5 13 621.88 20 15.09 1246 376 3.39 / 13.69 5 74
6 13 157.16 20 15.21 578 176 3.57 / 13.87 5 72
7 8 -0.04 345 15.19 314 1646 5.21 / 15.51 5 -99
Average= 3.88
(KJ/cycle)

Cycle 2 GMT 4/ 2/2022 8:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.84 31 15.20 439 207 0.21 / 5.20 5 13
2 10 1004.60 4 15.15 1763 107 0.31 / 5.30 5 43
3 3 1064.00 2 15.18 1869 57 0.37 / 5.36 5 40
4 7 1505.96 40 15.00 2431 1459 1.83 / 6.82 40 59
5 13 1428.76 20 14.99 2333 699 2.53 / 7.52 5 60
6 13 1229.00 20 14.98 2074 621 3.15 / 8.14 5 65
7 13 682.24 20 15.07 1332 401 3.55 / 8.54 5 74
8 13 120.32 20 15.23 527 161 3.71 / 8.70 5 68
9 8 0.08 332 15.19 317 1599 5.31 / 10.30 5 192
Average= 3.43
(KJ/cycle)

Cycle 1 GMT 2/ 2/2022 22:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 31 15.46 409 196 0.20 / 1.73 6 9
2 10 1013.00 4 15.22 1759 107 0.30 / 1.84 5 43
3 3 1045.76 1 15.23 1832 28 0.33 / 1.87 5 39
4 7 1014.84 41 15.11 1753 1086 1.42 / 2.95 39 66
5 13 584.68 20 15.19 1190 362 1.78 / 3.31 5 73
6 13 55.20 20 15.31 409 125 1.90 / 3.44 5 60
7 8 0.00 326 15.25 312 1551 3.45 / 4.99 5 -99
Average= 2.49
(KJ/cycle)

Cycle 0 GMT 2/ 2/2022 11:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 67.96 30 15.62 354 166 0.17 / 0.17 6 13
2 7 78.44 40 15.61 358 224 0.39 / 0.39 13 16
3 13 52.08 20 15.60 322 100 0.49 / 0.49 6 18
4 13 15.16 20 15.60 270 84 0.57 / 0.57 6 21
5 8 0.04 253 15.55 244 960 1.53 / 1.53 6 197
Average= 1.53
(KJ/cycle)