Cycle 76 GMT 6/ 5/2024 6:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 37 14.99 505 280 0.28 / 511.31 5 8
2 7 2010.84 40 14.75 3500 2065 2.35 / 513.38 8 25
3 13 1919.68 20 14.70 3419 1005 3.35 / 514.39 4 28
4 13 1498.64 20 14.71 2805 825 4.18 / 515.21 4 32
5 13 1054.64 20 14.77 2132 630 4.81 / 515.84 4 39
6 13 399.64 20 14.96 1060 317 5.12 / 516.16 4 42
7 13 15.92 20 15.08 389 117 5.24 / 516.27 4 27
8 8 -0.24 323 15.01 347 1682 6.92 / 517.96 4 142
Average= 7.51
(KJ/cycle)

Cycle 75 GMT 26/ 4/2024 9:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 37 15.00 504 280 0.28 / 504.33 5 8
2 7 2007.80 41 14.73 3519 2125 2.40 / 506.45 8 24
3 13 1922.48 20 14.70 3386 995 3.40 / 507.45 4 27
4 13 1409.60 20 14.72 2670 786 4.19 / 508.23 4 34
5 13 984.92 20 14.80 2013 596 4.78 / 508.83 4 39
6 13 413.60 20 14.96 1081 323 5.11 / 509.15 4 42
7 8 0.12 355 15.01 353 1881 6.99 / 511.03 4 142
Average= 7.52
(KJ/cycle)

Cycle 74 GMT 16/ 4/2024 12: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 37 14.99 506 281 0.28 / 497.49 5 8
2 7 2008.48 40 14.73 3528 2079 2.36 / 499.57 8 23
3 13 1912.16 20 14.71 3347 985 3.34 / 500.56 4 25
4 13 1487.80 20 14.70 2799 823 4.17 / 501.38 4 33
5 13 840.96 20 14.84 1796 533 4.70 / 501.91 4 40
6 13 202.12 20 15.02 722 217 4.92 / 502.13 4 38
7 8 0.08 361 15.01 354 1918 6.84 / 504.05 4 145
Average= 7.52
(KJ/cycle)

Cycle 73 GMT 6/ 4/2024 14:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 37 15.00 513 285 0.28 / 490.44 5 7
2 7 2003.68 40 14.73 3524 2076 2.36 / 492.52 7 24
3 13 1917.16 20 14.70 3382 994 3.36 / 493.51 4 25
4 13 1498.72 20 14.70 2816 828 4.18 / 494.34 4 32
5 13 1165.96 20 14.74 2308 680 4.86 / 495.02 4 36
6 13 367.00 20 14.97 1008 302 5.17 / 495.32 4 41
7 8 0.16 359 15.00 351 1890 7.06 / 497.21 4 154
Average= 7.53
(KJ/cycle)

Cycle 72 GMT 27/ 3/2024 17:27: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 37 15.00 551 306 0.31 / 483.48 5 7
2 7 2004.56 41 14.74 3494 2112 2.42 / 485.59 21 23
3 13 1914.20 20 14.70 3391 997 3.41 / 486.59 4 27
4 13 1478.72 20 14.71 2780 818 4.23 / 487.41 4 33
5 13 946.24 20 14.80 1963 581 4.81 / 487.99 4 40
6 13 399.36 20 14.96 1054 315 5.13 / 488.30 4 41
7 8 -0.04 349 15.01 354 1854 6.98 / 490.16 4 146
Average= 7.54
(KJ/cycle)

Cycle 71 GMT 17/ 3/2024 20:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 37 14.99 540 300 0.30 / 476.60 5 7
2 7 2011.48 40 14.74 3494 2060 2.36 / 478.66 7 23
3 13 1922.48 20 14.72 3376 994 3.35 / 479.66 4 27
4 13 1410.28 20 14.72 2689 792 4.15 / 480.45 4 34
5 13 886.44 20 14.82 1873 555 4.70 / 481.00 4 40
6 13 352.88 20 14.98 978 293 4.99 / 481.29 4 40
7 8 0.28 344 15.01 364 1879 6.87 / 483.17 4 141
Average= 7.55
(KJ/cycle)

Cycle 70 GMT 7/ 3/2024 22:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.56 38 14.99 547 312 0.31 / 469.60 5 6
2 3 957.80 -1 15.41 0 0 0.00 / 469.60 5 6
3 7 2003.32 40 14.73 3518 2073 2.38 / 471.68 6 24
4 13 1916.44 20 14.70 3368 990 3.37 / 472.67 4 27
5 13 1607.88 20 14.68 2937 862 4.24 / 473.53 4 31
6 13 951.72 20 14.80 1969 583 4.82 / 474.11 4 39
7 13 307.60 20 14.98 903 271 5.09 / 474.38 4 41
8 13 17.80 20 15.07 400 121 5.21 / 474.50 4 28
9 8 -0.20 338 15.00 355 1800 7.01 / 476.30 4 141
Average= 7.56
(KJ/cycle)

Cycle 69 GMT 27/ 2/2024 1:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 38 15.02 486 277 0.28 / 462.62 5 6
2 7 2012.84 40 14.73 3532 2081 2.36 / 464.70 6 23
3 13 1932.48 20 14.69 3432 1008 3.37 / 465.71 4 25
4 13 1617.00 20 14.68 2983 876 4.24 / 466.58 4 31
5 13 945.44 20 14.80 1954 578 4.82 / 467.16 4 39
6 13 390.28 20 14.96 1034 309 5.13 / 467.47 4 38
7 13 29.72 20 15.06 415 125 5.26 / 467.60 4 26
8 8 0.08 323 15.00 350 1696 6.95 / 469.29 4 157
Average= 7.57
(KJ/cycle)

Cycle 68 GMT 17/ 2/2024 4:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.96 38 15.03 494 282 0.28 / 455.77 5 6
2 7 2010.28 40 14.75 3485 2056 2.34 / 457.83 18 24
3 13 1920.96 20 14.70 3420 1005 3.34 / 458.83 4 26
4 13 1612.44 20 14.68 2982 876 4.22 / 459.71 4 30
5 13 867.00 20 14.83 1819 540 4.76 / 460.25 4 38
6 13 549.12 20 14.91 1298 387 5.15 / 460.64 4 39
7 8 0.16 332 15.01 342 1704 6.85 / 462.34 4 157
Average= 7.58
(KJ/cycle)

Cycle 67 GMT 7/ 2/2024 7: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 37 15.04 465 259 0.26 / 449.12 5 6
2 3 1031.52 1 15.12 2092 32 0.29 / 449.15 4 23
3 7 2012.04 41 14.75 3502 2118 2.41 / 451.27 23 22
4 13 1919.84 20 14.71 3401 1001 3.41 / 452.27 4 24
5 13 1407.92 20 14.72 2679 789 4.20 / 453.05 4 33
6 13 988.68 20 14.79 2030 600 4.80 / 453.66 4 39
7 13 128.92 20 15.05 580 175 4.97 / 453.83 4 31
8 8 -0.04 327 15.02 338 1660 6.63 / 455.49 4 167
Average= 7.59
(KJ/cycle)

Cycle 66 GMT 28/ 1/2024 9:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 37 14.98 558 309 0.31 / 442.36 4 10
2 7 2008.88 40 14.77 3478 2055 2.36 / 444.42 5 24
3 13 1918.44 20 14.74 3375 995 3.36 / 445.41 4 25
4 13 1508.92 20 14.72 2818 830 4.19 / 446.24 4 31
5 13 1071.52 20 14.78 2160 638 4.83 / 446.88 4 37
6 13 397.28 20 14.97 1042 312 5.14 / 447.19 4 38
7 13 18.60 20 15.09 378 114 5.25 / 447.31 4 26
8 8 0.04 308 15.03 335 1551 6.80 / 448.86 4 149
Average= 7.61
(KJ/cycle)

Cycle 65 GMT 18/ 1/2024 12:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.96 37 14.99 506 281 0.28 / 435.31 4 10
2 7 2009.68 40 14.76 3500 2066 2.35 / 437.38 10 23
3 13 1919.68 20 14.73 3397 1001 3.35 / 438.38 4 27
4 13 1498.60 20 14.72 2809 827 4.17 / 439.21 4 33
5 13 858.32 20 14.84 1826 542 4.72 / 439.75 4 40
6 13 226.80 20 15.02 771 232 4.95 / 439.98 4 40
7 8 0.28 379 15.01 364 2071 7.02 / 442.05 4 147
Average= 7.62
(KJ/cycle)

Cycle 64 GMT 8/ 1/2024 14:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 37 14.98 562 311 0.31 / 428.30 4 11
2 7 2014.28 40 14.76 3504 2069 2.38 / 430.37 11 24
3 13 1927.52 20 14.73 3392 999 3.38 / 431.37 4 25
4 13 1506.36 20 14.72 2808 827 4.21 / 432.19 4 34
5 13 867.20 20 14.84 1838 546 4.75 / 432.74 4 40
6 13 335.96 20 14.98 955 286 5.04 / 433.03 4 42
7 8 0.00 379 15.01 353 2008 7.05 / 435.03 4 141
Average= 7.63
(KJ/cycle)

Cycle 63 GMT 29/12/2023 17:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 37 14.96 568 314 0.31 / 421.35 4 18
2 7 2003.36 40 14.77 3523 2081 2.40 / 423.43 18 22
3 13 1914.48 20 14.75 3347 987 3.38 / 424.41 4 27
4 13 1304.76 20 14.77 2504 740 4.12 / 425.15 4 35
5 13 887.76 20 14.82 1879 557 4.68 / 425.71 4 41
6 13 136.00 20 15.05 608 183 4.86 / 425.89 4 37
7 8 0.20 376 15.01 371 2094 6.96 / 427.99 4 130
Average= 7.64
(KJ/cycle)

Cycle 62 GMT 19/12/2023 20:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 36 14.98 559 301 0.30 / 414.07 4 14
2 7 2009.04 41 14.77 3502 2121 2.42 / 416.20 4 23
3 13 1921.60 20 14.73 3418 1007 3.43 / 417.20 4 25
4 13 1391.04 20 14.75 2649 781 4.21 / 417.98 4 34
5 13 960.84 20 14.81 1986 588 4.80 / 418.57 4 40
6 13 303.28 20 15.00 898 269 5.07 / 418.84 4 42
7 8 0.00 400 15.00 365 2190 7.26 / 421.03 4 104
Average= 7.66
(KJ/cycle)

Cycle 61 GMT 9/12/2023 22:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 36 14.97 566 305 0.31 / 406.79 4 15
2 7 2007.44 40 14.78 3514 2077 2.38 / 408.87 15 23
3 13 1912.40 20 14.75 3375 996 3.38 / 409.87 4 25
4 13 1606.36 20 14.72 2955 870 4.25 / 410.74 4 30
5 13 1041.04 20 14.80 2100 622 4.87 / 411.36 4 39
6 13 379.64 20 14.98 1019 305 5.17 / 411.66 4 42
7 8 0.08 398 15.01 353 2109 7.28 / 413.77 4 145
Average= 7.66
(KJ/cycle)

Cycle 60 GMT 30/11/2023 1:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.08 36 14.98 575 310 0.31 / 399.61 4 14
2 7 2010.52 40 14.78 3508 2074 2.38 / 401.69 14 25
3 13 1925.24 20 14.76 3388 1000 3.38 / 402.69 4 28
4 13 1618.84 20 14.71 2988 879 4.26 / 403.56 4 30
5 13 856.96 20 14.85 1822 541 4.80 / 404.11 4 40
6 13 312.88 20 15.00 916 275 5.08 / 404.38 4 42
7 8 0.28 400 15.02 351 2109 7.19 / 406.49 4 93
Average= 7.67
(KJ/cycle)

Cycle 59 GMT 20/11/2023 4:14:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 36 14.98 572 308 0.31 / 392.41 4 17
2 7 2013.68 40 14.77 3530 2086 2.39 / 394.50 17 23
3 13 1922.12 20 14.75 3412 1007 3.40 / 395.50 4 25
4 13 1389.36 20 14.77 2631 777 4.18 / 396.28 4 33
5 13 957.76 20 14.82 1982 587 4.77 / 396.87 4 40
6 13 204.04 20 15.05 726 219 4.98 / 397.09 4 40
7 8 0.16 400 15.01 369 2215 7.20 / 399.30 4 107
Average= 7.68
(KJ/cycle)

Cycle 58 GMT 10/11/2023 6:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.76 36 14.98 579 312 0.31 / 385.09 4 19
2 7 2003.16 40 14.79 3498 2069 2.38 / 387.16 19 24
3 13 1911.88 20 14.76 3392 1001 3.38 / 388.16 4 26
4 13 1495.08 20 14.75 2796 825 4.21 / 388.98 4 32
5 13 856.04 20 14.87 1823 542 4.75 / 389.53 4 39
6 13 419.36 20 14.98 1097 329 5.08 / 389.86 4 43
7 8 -0.08 400 15.02 374 2247 7.33 / 392.10 4 96
Average= 7.69
(KJ/cycle)

Cycle 57 GMT 31/10/2023 9:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 36 15.00 549 296 0.30 / 377.73 4 18
2 7 2004.60 40 14.79 3515 2079 2.38 / 379.80 18 22
3 13 1906.72 20 14.78 3360 993 3.37 / 380.80 4 28
4 13 1474.28 20 14.76 2781 821 4.19 / 381.62 4 34
5 13 1030.76 20 14.82 2100 622 4.81 / 382.24 4 39
6 13 358.20 20 15.00 1002 301 5.11 / 382.54 4 43
7 8 0.00 400 15.02 372 2235 7.35 / 384.78 4 64
Average= 7.70
(KJ/cycle)

Cycle 56 GMT 21/10/2023 12:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.40 35 15.01 521 274 0.27 / 370.46 4 18
2 7 2013.08 40 14.78 3536 2090 2.36 / 372.55 4 22
3 13 1924.84 20 14.76 3408 1006 3.37 / 373.56 4 27
4 13 1496.60 20 14.76 2796 825 4.20 / 374.38 4 32
5 13 958.92 20 14.84 1989 590 4.79 / 374.97 4 39
6 13 311.08 20 15.02 916 275 5.06 / 375.25 4 43
7 8 0.16 400 15.03 363 2182 7.24 / 377.43 4 76
Average= 7.70
(KJ/cycle)

Cycle 55 GMT 11/10/2023 15: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 35 15.00 588 309 0.31 / 363.17 4 18
2 7 2010.60 40 14.79 3510 2077 2.39 / 365.25 4 24
3 13 1917.52 20 14.77 3382 999 3.38 / 366.25 4 25
4 13 1608.00 20 14.74 2982 879 4.26 / 367.13 4 31
5 13 1050.16 20 14.83 2130 632 4.90 / 367.76 4 40
6 13 285.32 20 15.04 867 261 5.16 / 368.02 4 41
7 8 0.00 400 15.04 360 2166 7.32 / 370.19 4 98
Average= 7.71
(KJ/cycle)

Cycle 54 GMT 1/10/2023 17:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.24 35 15.02 531 279 0.28 / 355.85 4 18
2 7 2006.88 40 14.80 3498 2071 2.35 / 357.92 18 25
3 13 1923.68 20 14.78 3397 1004 3.35 / 358.92 4 27
4 13 1607.12 20 14.74 2974 877 4.23 / 359.80 4 33
5 13 853.80 20 14.89 1825 543 4.77 / 360.34 4 39
6 13 416.32 20 15.00 1102 331 5.10 / 360.67 4 44
7 8 0.32 400 15.04 364 2190 7.29 / 362.86 4 105
Average= 7.72
(KJ/cycle)

Cycle 53 GMT 21/ 9/2023 20:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.00 35 15.03 525 276 0.28 / 348.52 4 17
2 7 2004.64 40 14.80 3520 2084 2.36 / 350.60 17 25
3 13 1909.28 20 14.76 3395 1002 3.36 / 351.61 4 26
4 13 1701.08 20 14.74 3088 910 4.27 / 352.52 4 31
5 13 929.00 20 14.87 1945 578 4.85 / 353.10 4 42
6 13 366.52 20 15.03 1019 306 5.16 / 353.40 4 43
7 8 -0.12 400 15.05 360 2167 7.32 / 355.57 4 84
Average= 7.73
(KJ/cycle)

Cycle 52 GMT 11/ 9/2023 23:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 35 15.03 516 271 0.27 / 341.35 4 15
2 7 2004.28 40 14.81 3503 2075 2.35 / 343.42 15 24
3 13 1911.08 20 14.78 3393 1003 3.35 / 344.43 4 28
4 13 1589.76 20 14.76 2930 865 4.21 / 345.29 4 33
5 13 922.32 20 14.88 1929 574 4.79 / 345.87 4 39
6 13 158.96 20 15.10 652 197 4.99 / 346.06 4 39
7 8 0.20 400 15.06 362 2181 7.17 / 348.24 4 126
Average= 7.74
(KJ/cycle)

Cycle 51 GMT 2/ 9/2023 2: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 36 15.04 524 284 0.28 / 334.24 4 13
2 7 2004.84 40 14.80 3512 2079 2.36 / 336.32 13 24
3 13 1913.76 20 14.77 3381 999 3.36 / 337.32 4 27
4 13 1385.80 20 14.80 2667 789 4.15 / 338.11 4 35
5 13 763.24 20 14.93 1679 501 4.65 / 338.61 4 41
6 13 329.92 20 15.04 951 286 4.94 / 338.89 4 43
7 8 0.08 400 15.05 363 2185 7.12 / 341.08 4 125
Average= 7.75
(KJ/cycle)

Cycle 50 GMT 23/ 8/2023 4:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 36 15.03 522 282 0.28 / 327.24 4 14
2 7 2003.80 41 14.81 3485 2116 2.40 / 329.36 14 25
3 13 1907.56 20 14.78 3376 998 3.40 / 330.35 4 27
4 13 1396.80 20 14.80 2659 787 4.18 / 331.14 4 35
5 13 853.56 20 14.91 1823 544 4.73 / 331.68 4 42
6 13 12.92 20 15.15 399 121 4.85 / 331.81 4 23
7 8 0.36 391 15.06 365 2149 7.00 / 333.95 4 137
Average= 7.77
(KJ/cycle)

Cycle 49 GMT 13/ 8/2023 7: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.48 36 15.03 536 290 0.29 / 320.01 4 16
2 7 2017.24 40 14.80 3496 2070 2.36 / 322.08 16 24
3 13 1937.12 20 14.77 3439 1016 3.38 / 323.09 4 26
4 13 1510.92 20 14.78 2822 834 4.21 / 323.93 4 33
5 13 870.36 20 14.91 1848 551 4.76 / 324.48 4 42
6 13 316.88 20 15.05 929 280 5.04 / 324.76 4 44
7 8 0.04 400 15.06 365 2199 7.24 / 326.96 4 104
Average= 7.78
(KJ/cycle)

Cycle 48 GMT 3/ 8/2023 9:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 38 15.09 501 287 0.29 / 312.75 5 7
2 3 966.52 -1 15.45 0 0 0.00 / 312.75 5 7
3 7 2005.60 40 14.80 3536 2093 2.38 / 314.84 7 22
4 13 1917.56 20 14.77 3394 1003 3.38 / 315.84 4 27
5 13 1588.28 20 14.77 2922 863 4.25 / 316.71 4 32
6 13 1036.52 20 14.86 2099 624 4.87 / 317.33 4 38
7 13 178.72 20 15.10 684 207 5.08 / 317.54 4 38
8 8 0.16 400 15.06 362 2181 7.26 / 319.72 4 118
Average= 7.80
(KJ/cycle)

Cycle 47 GMT 24/ 7/2023 12:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.16 37 15.12 489 274 0.27 / 306.08 5 7
2 3 1045.44 1 15.17 2103 32 0.31 / 306.11 4 16
3 7 2010.12 40 14.81 3505 2076 2.38 / 308.18 16 24
4 13 1921.48 20 14.76 3403 1005 3.39 / 309.19 4 26
5 13 1502.72 20 14.78 2798 827 4.21 / 310.02 4 33
6 13 877.80 20 14.90 1854 552 4.77 / 310.57 4 38
7 13 133.12 20 15.13 583 176 4.94 / 310.75 4 30
8 8 0.16 334 15.10 340 1715 6.66 / 312.46 4 174
Average= 7.81
(KJ/cycle)

Cycle 46 GMT 14/ 7/2023 14:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.84 36 15.09 510 277 0.28 / 299.54 4 13
2 7 2008.40 41 14.82 3509 2132 2.41 / 301.67 5 22
3 13 1915.92 20 14.80 3378 1000 3.41 / 302.67 4 24
4 13 1507.12 20 14.80 2806 831 4.24 / 303.50 4 30
5 13 874.04 20 14.94 1847 552 4.79 / 304.05 4 40
6 13 133.08 20 15.16 565 171 4.96 / 304.22 4 25
7 8 0.08 319 15.13 327 1578 6.54 / 305.80 4 137
Average= 7.84
(KJ/cycle)

Cycle 45 GMT 4/ 7/2023 17:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.92 35 15.09 502 265 0.27 / 292.74 4 11
2 3 1042.16 1 15.14 2119 32 0.30 / 292.77 4 12
3 7 2013.92 40 14.81 3516 2083 2.38 / 294.85 12 24
4 13 1922.80 20 14.79 3373 998 3.38 / 295.85 4 26
5 13 1399.24 20 14.83 2643 784 4.16 / 296.63 4 33
6 13 866.72 20 14.93 1838 549 4.71 / 297.18 4 40
7 13 223.24 20 15.12 747 226 4.94 / 297.41 4 36
8 8 0.04 359 15.11 342 1855 6.79 / 299.26 4 156
Average= 7.88
(KJ/cycle)

Cycle 44 GMT 24/ 6/2023 19:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.04 35 15.06 533 281 0.28 / 285.77 4 15
2 7 2005.20 40 14.82 3534 2095 2.38 / 287.86 15 21
3 13 1916.44 20 14.80 3369 997 3.37 / 288.86 4 26
4 13 1595.76 20 14.80 2933 868 4.24 / 289.73 4 33
5 13 1034.60 20 14.90 2107 628 4.87 / 290.35 4 39
6 13 267.20 20 15.12 821 248 5.12 / 290.60 4 37
7 8 0.40 359 15.12 344 1867 6.98 / 292.47 4 161
Average= 7.90
(KJ/cycle)

Cycle 43 GMT 14/ 6/2023 22:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 35 15.07 533 281 0.28 / 278.64 4 12
2 7 2006.60 40 14.82 3508 2080 2.36 / 280.72 4 22
3 13 1921.00 20 14.81 3372 999 3.36 / 281.72 4 27
4 13 1414.32 20 14.84 2673 793 4.15 / 282.51 4 34
5 13 862.20 20 14.94 1835 548 4.70 / 283.06 4 40
6 13 330.72 20 15.08 954 288 4.99 / 283.35 4 43
7 8 0.00 398 15.09 356 2138 7.13 / 285.49 4 160
Average= 7.93
(KJ/cycle)

Cycle 42 GMT 5/ 6/2023 1:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 35 15.08 514 271 0.27 / 271.62 4 11
2 7 2006.36 40 14.83 3511 2083 2.35 / 273.70 4 23
3 13 1919.20 20 14.81 3376 1000 3.35 / 274.70 4 27
4 13 1406.80 20 14.85 2666 792 4.15 / 275.49 4 32
5 13 876.04 20 14.95 1850 553 4.70 / 276.05 4 40
6 13 222.56 20 15.12 762 230 4.93 / 276.28 4 40
7 8 0.08 385 15.10 358 2081 7.01 / 278.36 4 138
Average= 7.95
(KJ/cycle)

Cycle 41 GMT 26/ 5/2023 3:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 35 15.09 507 268 0.27 / 264.54 4 11
2 7 2007.08 40 14.83 3500 2076 2.34 / 266.62 4 24
3 13 1914.68 20 14.80 3398 1006 3.35 / 267.62 4 27
4 13 1489.40 20 14.83 2793 828 4.18 / 268.45 4 34
5 13 845.76 20 14.96 1807 541 4.72 / 268.99 4 41
6 13 285.80 20 15.10 869 262 4.98 / 269.25 4 42
7 8 -0.04 387 15.11 358 2093 7.07 / 271.35 4 147
Average= 7.98
(KJ/cycle)

Cycle 40 GMT 16/ 5/2023 6:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 35 15.09 520 275 0.27 / 257.43 4 10
2 7 2004.72 40 14.83 3504 2079 2.35 / 259.51 10 22
3 13 1920.12 20 14.81 3410 1010 3.36 / 260.52 4 27
4 13 1595.96 20 14.81 2940 871 4.23 / 261.39 4 30
5 13 914.20 20 14.94 1918 573 4.81 / 261.96 4 41
6 13 259.88 20 15.12 829 251 5.06 / 262.21 4 41
7 8 0.08 381 15.11 358 2061 7.12 / 264.27 4 134
Average= 8.01
(KJ/cycle)

Cycle 39 GMT 6/ 5/2023 9:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 36 15.10 504 274 0.27 / 250.45 4 10
2 3 951.80 -1 15.46 0 0 0.00 / 250.45 4 10
3 7 2006.00 41 14.84 3487 2122 2.40 / 252.57 10 24
4 13 1923.96 20 14.82 3375 1000 3.40 / 253.57 4 25
5 13 1503.16 20 14.83 2810 833 4.23 / 254.40 4 33
6 13 844.96 20 14.96 1802 539 4.77 / 254.94 4 41
7 13 199.92 20 15.14 721 218 4.99 / 255.16 4 40
8 13 45.68 20 15.18 446 135 5.12 / 255.30 4 33
9 13 28.08 20 15.17 412 125 5.25 / 255.42 4 30
10 8 0.12 327 15.11 351 1734 6.98 / 257.15 4 133
Average= 8.04
(KJ/cycle)

Cycle 38 GMT 26/ 4/2023 11:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 36 15.12 505 275 0.27 / 243.41 4 9
2 7 2005.88 40 14.83 3510 2082 2.36 / 245.50 9 23
3 13 1916.92 20 14.81 3379 1001 3.36 / 246.50 4 27
4 13 1382.00 20 14.85 2644 785 4.14 / 247.28 4 34
5 13 964.52 20 14.93 1993 595 4.74 / 247.88 4 41
6 13 302.52 20 15.11 903 273 5.01 / 248.15 4 42
7 8 0.08 376 15.12 356 2024 7.04 / 250.17 4 134
Average= 8.07
(KJ/cycle)

Cycle 37 GMT 16/ 4/2023 14:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 37 15.11 499 279 0.28 / 236.59 4 9
2 7 2014.56 41 14.83 3546 2156 2.44 / 238.74 9 21
3 13 1928.16 20 14.82 3398 1007 3.44 / 239.75 4 27
4 13 1497.32 20 14.85 2785 827 4.27 / 240.58 4 33
5 13 855.00 20 14.97 1818 544 4.81 / 241.12 4 41
6 13 105.36 20 15.19 540 164 4.98 / 241.29 4 33
7 13 55.56 20 15.19 455 138 5.12 / 241.42 4 31
8 8 0.20 329 15.14 344 1713 6.83 / 243.14 4 149
Average= 8.10
(KJ/cycle)

Cycle 36 GMT 6/ 4/2023 17:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 36 15.14 494 269 0.27 / 229.71 5 7
2 7 2003.60 40 14.85 3477 2065 2.33 / 231.78 7 24
3 13 1911.20 20 14.82 3391 1005 3.34 / 232.78 4 26
4 13 1480.88 20 14.85 2786 827 4.17 / 233.61 4 32
5 13 841.60 20 14.98 1797 538 4.71 / 234.15 4 41
6 13 318.72 20 15.12 916 277 4.98 / 234.43 4 39
7 8 -0.08 357 15.14 348 1881 6.86 / 236.31 4 155
Average= 8.15
(KJ/cycle)

Cycle 35 GMT 27/ 3/2023 20: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 36 15.15 497 271 0.27 / 223.02 5 8
2 7 2006.84 40 14.85 3510 2085 2.36 / 225.11 8 24
3 13 1915.12 20 14.84 3359 997 3.35 / 226.11 4 27
4 13 1505.08 20 14.85 2822 838 4.19 / 226.94 4 31
5 13 863.12 20 14.97 1837 550 4.74 / 227.49 4 40
6 13 227.76 20 15.16 759 230 4.97 / 227.72 4 36
7 8 0.28 336 15.15 338 1721 6.69 / 229.45 4 184
Average= 8.19
(KJ/cycle)

Cycle 34 GMT 17/ 3/2023 22:35: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 36 15.14 500 273 0.27 / 216.16 5 8
2 7 2004.20 40 14.85 3515 2088 2.36 / 218.25 8 23
3 13 1916.20 20 14.83 3370 1000 3.36 / 219.25 4 26
4 13 1606.12 20 14.84 2946 874 4.23 / 220.12 4 31
5 13 946.52 20 14.96 1964 588 4.82 / 220.71 4 38
6 13 288.56 20 15.14 854 259 5.08 / 220.97 4 37
7 8 -0.08 349 15.15 338 1787 6.87 / 222.75 4 152
Average= 8.25
(KJ/cycle)

Cycle 33 GMT 8/ 3/2023 1:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 36 15.13 516 281 0.28 / 209.41 4 9
2 7 2010.44 40 14.86 3476 2066 2.35 / 211.48 9 23
3 13 1926.80 20 14.84 3405 1011 3.36 / 212.49 4 26
4 13 1489.72 20 14.87 2776 826 4.18 / 213.31 4 32
5 13 942.08 20 14.97 1955 585 4.77 / 213.90 4 38
6 13 190.52 20 15.17 688 209 4.98 / 214.11 4 35
7 8 0.08 351 15.16 334 1777 6.75 / 215.89 4 133
Average= 8.30
(KJ/cycle)

Cycle 32 GMT 26/ 2/2023 3:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 36 15.14 507 276 0.28 / 202.49 5 7
2 3 1030.76 1 15.17 2115 32 0.31 / 202.53 4 7
3 7 2006.56 40 14.87 3495 2079 2.39 / 204.60 7 24
4 13 1913.48 20 14.84 3380 1003 3.39 / 205.61 4 25
5 13 1500.32 20 14.86 2802 833 4.22 / 206.44 4 31
6 13 1057.80 20 14.93 2138 638 4.86 / 207.08 4 37
7 13 277.96 20 15.14 856 259 5.12 / 207.34 4 39
8 8 0.00 340 15.15 348 1793 6.91 / 209.13 4 140
Average= 8.37
(KJ/cycle)

Cycle 31 GMT 16/ 2/2023 6:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.28 36 15.13 500 272 0.27 / 195.56 4 9
2 7 2014.96 40 14.86 3538 2103 2.38 / 197.67 9 23
3 13 1931.12 20 14.85 3380 1004 3.38 / 198.67 4 26
4 13 1410.00 20 14.89 2670 795 4.17 / 199.47 4 34
5 13 994.08 20 14.95 2035 608 4.78 / 200.08 4 39
6 13 326.24 20 15.13 932 282 5.06 / 200.36 4 39
7 8 -0.04 357 15.15 344 1861 6.93 / 202.22 4 144
Average= 8.43
(KJ/cycle)

Cycle 30 GMT 6/ 2/2023 9:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 36 15.14 524 286 0.29 / 188.58 4 9
2 7 2005.52 40 14.87 3495 2079 2.36 / 190.66 9 24
3 13 1924.04 20 14.84 3391 1006 3.37 / 191.67 4 25
4 13 1495.36 20 14.87 2808 835 4.21 / 192.51 4 33
5 13 864.24 20 14.99 1837 551 4.76 / 193.06 4 40
6 13 225.44 20 15.17 762 231 4.99 / 193.29 4 39
7 8 0.16 376 15.15 352 2005 6.99 / 195.29 4 179
Average= 8.49
(KJ/cycle)

Cycle 29 GMT 27/ 1/2023 11:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.20 36 15.17 480 262 0.26 / 181.20 5 7
2 7 2032.28 40 14.86 3536 2102 2.36 / 183.30 7 22
3 13 2006.64 20 14.83 3509 1041 3.40 / 184.35 4 26
4 13 1540.08 20 14.86 2880 856 4.26 / 185.20 4 32
5 13 980.64 20 14.96 2015 603 4.86 / 185.80 4 39
6 13 884.64 20 14.95 1864 557 5.42 / 186.36 4 41
7 8 0.00 374 15.15 342 1938 7.36 / 188.30 4 151
Average= 8.56
(KJ/cycle)

Cycle 28 GMT 17/ 1/2023 14:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.60 36 15.18 497 272 0.27 / 174.49 5 6
2 7 2012.00 40 14.86 3503 2082 2.35 / 176.57 6 21
3 13 1919.76 20 14.85 3379 1004 3.36 / 177.57 4 26
4 13 1502.40 20 14.88 2804 834 4.19 / 178.41 4 33
5 13 951.24 20 14.98 1954 585 4.78 / 178.99 4 40
6 13 192.20 20 15.19 679 206 4.98 / 179.20 4 35
7 8 0.08 351 15.18 327 1742 6.73 / 180.94 4 218
Average= 8.62
(KJ/cycle)

Cycle 27 GMT 7/ 1/2023 17:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 36 15.15 492 268 0.27 / 167.84 4 9
2 7 2004.76 40 14.87 3490 2076 2.34 / 169.92 9 23
3 13 1914.60 20 14.87 3340 993 3.34 / 170.91 4 26
4 13 1390.16 20 14.91 2641 788 4.13 / 171.70 4 33
5 13 952.20 20 14.98 1952 585 4.71 / 172.29 4 39
6 13 185.72 20 15.20 669 203 4.91 / 172.49 4 36
7 8 0.08 351 15.18 324 1726 6.64 / 174.21 4 150
Average= 8.71
(KJ/cycle)

Cycle 26 GMT 28/12/2022 19:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.04 36 15.16 503 275 0.27 / 160.89 4 10
2 7 2010.20 40 14.88 3526 2099 2.37 / 162.99 10 23
3 13 1915.68 20 14.88 3349 997 3.37 / 163.99 4 26
4 13 1398.60 20 14.92 2633 786 4.16 / 164.77 4 32
5 13 964.12 20 14.98 1975 592 4.75 / 165.37 4 37
6 13 406.76 20 15.13 1052 318 5.07 / 165.68 4 41
7 8 0.28 372 15.17 335 1890 6.96 / 167.58 4 141
Average= 8.82
(KJ/cycle)

Cycle 25 GMT 18/12/2022 22:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 35 15.17 482 256 0.26 / 154.08 5 9
2 7 2007.96 40 14.89 3460 2061 2.32 / 156.14 4 24
3 13 1913.08 20 14.87 3340 993 3.31 / 157.13 4 26
4 13 1495.36 20 14.90 2782 829 4.14 / 157.96 4 32
5 13 947.52 20 14.99 1943 583 4.72 / 158.54 4 40
6 13 185.24 20 15.20 671 204 4.93 / 158.75 4 37
7 8 -0.16 374 15.18 330 1874 6.80 / 160.62 4 134
Average= 8.92
(KJ/cycle)

Cycle 24 GMT 9/12/2022 1:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.52 35 15.15 498 264 0.26 / 147.39 4 11
2 7 2006.24 40 14.90 3460 2062 2.33 / 149.45 11 22
3 13 1922.24 20 14.87 3363 1000 3.33 / 150.45 4 26
4 13 1407.20 20 14.92 2658 793 4.12 / 151.24 4 32
5 13 875.56 20 15.02 1833 551 4.67 / 151.80 4 38
6 13 133.28 20 15.22 578 176 4.85 / 151.97 4 35
7 8 0.16 370 15.19 329 1849 6.70 / 153.82 4 141
Average= 9.05
(KJ/cycle)

Cycle 23 GMT 29/11/2022 3:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.88 35 15.16 501 266 0.27 / 140.37 4 11
2 7 2006.24 41 14.89 3481 2125 2.39 / 142.49 11 24
3 13 1914.64 20 14.88 3362 1001 3.39 / 143.50 4 25
4 13 1487.08 20 14.91 2760 823 4.21 / 144.32 4 31
5 13 950.92 20 15.00 1953 586 4.80 / 144.90 4 39
6 13 277.36 20 15.18 830 252 5.05 / 145.16 4 39
7 8 0.04 393 15.18 330 1969 7.02 / 147.12 4 147
Average= 9.20
(KJ/cycle)

Cycle 22 GMT 19/11/2022 6:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 35 15.16 496 263 0.26 / 133.48 4 12
2 7 2011.12 40 14.90 3486 2078 2.34 / 135.56 12 22
3 13 1918.68 20 14.87 3377 1004 3.35 / 136.56 4 27
4 13 1491.76 20 14.91 2760 823 4.17 / 137.39 4 31
5 13 845.20 20 15.04 1765 531 4.70 / 137.92 4 39
6 13 199.52 20 15.21 697 212 4.91 / 138.13 4 38
7 8 0.08 385 15.18 338 1975 6.89 / 140.10 4 162
Average= 9.34
(KJ/cycle)

Cycle 21 GMT 9/11/2022 9: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 35 15.17 501 266 0.27 / 126.58 4 11
2 7 2007.76 40 14.91 3452 2059 2.32 / 128.64 11 23
3 13 1926.04 20 14.89 3372 1004 3.33 / 129.64 4 25
4 13 1508.52 20 14.92 2791 833 4.16 / 130.47 4 33
5 13 856.72 20 15.03 1798 540 4.70 / 131.01 4 40
6 13 201.96 20 15.20 705 214 4.92 / 131.23 4 38
7 8 0.24 391 15.18 335 1988 6.90 / 133.22 4 158
Average= 9.52
(KJ/cycle)

Cycle 20 GMT 30/10/2022 11:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.72 35 15.17 492 261 0.26 / 119.75 4 13
2 3 1021.64 1 15.21 2131 32 0.29 / 119.78 4 4
3 7 2014.76 40 14.89 3528 2101 2.39 / 121.88 4 22
4 13 1927.32 20 14.88 3404 1013 3.41 / 122.90 4 26
5 13 1503.16 20 14.92 2792 833 4.24 / 123.73 4 33
6 13 842.68 20 15.03 1779 535 4.78 / 124.27 4 40
7 13 197.12 20 15.21 689 210 4.99 / 124.48 4 38
8 8 0.20 361 15.19 335 1837 6.82 / 126.31 4 151
Average= 9.72
(KJ/cycle)

Cycle 19 GMT 20/10/2022 14:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.08 36 15.17 497 271 0.27 / 112.92 4 11
2 3 966.00 -1 15.52 0 0 0.00 / 112.92 4 11
3 7 2004.48 40 14.91 3471 2070 2.34 / 114.99 11 23
4 13 1910.40 20 14.91 3330 993 3.33 / 115.99 4 27
5 13 1386.00 20 14.94 2625 784 4.12 / 116.77 4 33
6 13 857.92 20 15.04 1804 543 4.66 / 117.31 4 39
7 13 192.52 20 15.21 684 208 4.87 / 117.52 4 38
8 8 0.04 389 15.19 333 1968 6.84 / 119.49 4 136
Average= 9.96
(KJ/cycle)

Cycle 18 GMT 10/10/2022 16:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.80 36 15.19 502 275 0.27 / 105.87 4 11
2 7 2007.00 40 14.91 3477 2074 2.35 / 107.94 11 24
3 13 1923.28 20 14.90 3387 1009 3.36 / 108.95 4 25
4 13 1504.64 20 14.93 2780 830 4.19 / 109.78 4 32
5 13 1062.08 20 14.99 2125 637 4.82 / 110.42 4 38
6 13 289.64 20 15.19 856 260 5.08 / 110.68 4 40
7 8 0.08 387 15.19 336 1975 7.06 / 112.65 4 139
Average= 10.24
(KJ/cycle)

Cycle 17 GMT 30/ 9/2022 19:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 35 15.21 492 262 0.26 / 98.89 5 8
2 3 1056.92 1 15.24 2119 32 0.29 / 98.92 4 10
3 7 2005.08 40 14.92 3492 2084 2.38 / 101.01 10 20
4 13 1918.84 20 14.90 3387 1009 3.39 / 102.02 4 25
5 13 1591.20 20 14.92 2912 869 4.26 / 102.89 4 29
6 13 1028.68 20 15.01 2059 618 4.87 / 103.51 4 36
7 13 243.24 20 15.22 765 233 5.11 / 103.74 4 35
8 8 -0.04 364 15.21 335 1855 6.96 / 105.59 4 154
Average= 10.56
(KJ/cycle)

Cycle 16 GMT 20/ 9/2022 22:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 37 15.18 522 293 0.29 / 92.35 4 12
2 3 949.40 -1 15.54 0 0 0.00 / 92.35 4 12
3 7 2004.24 40 14.92 3500 2089 2.38 / 94.44 12 22
4 13 1922.76 20 14.91 3388 1010 3.39 / 95.45 4 26
5 13 1512.36 20 14.94 2793 835 4.23 / 96.28 4 31
6 13 886.92 20 15.05 1853 558 4.78 / 96.84 4 38
7 13 145.92 20 15.25 588 179 4.96 / 97.02 4 29
8 8 0.08 329 15.23 322 1613 6.58 / 98.63 5 139
Average= 10.96
(KJ/cycle)

Cycle 15 GMT 11/ 9/2022 1: 6:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 35 15.23 485 259 0.26 / 85.44 5 7
2 3 1060.92 2 15.26 2121 65 0.32 / 85.51 4 13
3 7 2009.52 40 14.92 3502 2090 2.41 / 87.60 13 22
4 13 1911.24 20 14.91 3400 1014 3.43 / 88.61 4 25
5 13 1394.20 20 14.97 2611 782 4.21 / 89.39 4 33
6 13 869.76 20 15.04 1844 555 4.76 / 89.95 4 38
7 13 210.56 20 15.22 731 223 4.99 / 90.17 4 38
8 8 -0.20 366 15.21 338 1882 6.87 / 92.05 4 132
Average= 11.51
(KJ/cycle)

Cycle 14 GMT 1/ 9/2022 3:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 34 15.19 525 271 0.27 / 78.71 4 12
2 3 1025.92 1 15.23 2124 32 0.30 / 78.75 4 5
3 7 2007.92 41 14.94 3470 2126 2.43 / 80.87 5 22
4 13 1810.84 20 14.94 3239 968 3.40 / 81.84 4 26
5 13 1608.84 20 14.92 2961 884 4.28 / 82.72 4 31
6 13 929.08 20 15.04 1924 579 4.86 / 83.30 4 37
7 13 370.44 20 15.19 985 299 5.16 / 83.60 4 34
8 8 0.04 323 15.24 322 1585 6.74 / 85.19 4 148
Average= 12.17
(KJ/cycle)

Cycle 13 GMT 22/ 8/2022 6:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 34 15.19 518 268 0.27 / 71.74 4 10
2 7 2009.60 40 14.93 3514 2099 2.37 / 73.84 10 22
3 13 1924.60 20 14.92 3416 1019 3.39 / 74.86 4 26
4 13 1600.00 20 14.93 2957 883 4.27 / 75.74 4 31
5 13 772.24 20 15.08 1691 510 4.78 / 76.25 4 40
6 13 249.00 20 15.22 791 241 5.02 / 76.49 4 37
7 8 0.16 366 15.21 350 1948 6.97 / 78.44 4 132
Average= 13.07
(KJ/cycle)

Cycle 12 GMT 12/ 8/2022 8:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 34 15.19 517 267 0.27 / 64.84 4 10
2 7 2008.44 40 14.94 3493 2087 2.35 / 66.93 10 22
3 13 1809.00 20 14.94 3220 962 3.32 / 67.89 4 27
4 13 1487.56 20 14.95 2777 830 4.15 / 68.72 4 33
5 13 934.24 20 15.03 1951 586 4.73 / 69.31 4 40
6 13 168.60 20 15.24 668 204 4.94 / 69.51 4 39
7 13 14.08 20 15.27 391 119 5.06 / 69.63 4 27
8 8 -0.04 344 15.21 352 1842 6.90 / 71.47 4 149
Average= 14.29
(KJ/cycle)

Cycle 11 GMT 2/ 8/2022 11:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.00 35 15.19 525 279 0.28 / 58.02 4 10
2 7 2005.20 40 14.94 3492 2087 2.37 / 60.11 10 23
3 13 1912.88 20 14.93 3370 1006 3.37 / 61.11 4 26
4 13 1298.28 20 14.99 2499 749 4.12 / 61.86 4 35
5 13 975.28 20 15.02 2006 603 4.72 / 62.46 4 40
6 13 95.36 20 15.26 534 163 4.89 / 62.63 4 36
7 8 -0.04 361 15.21 355 1949 6.84 / 64.58 4 140
Average= 16.14
(KJ/cycle)

Cycle 10 GMT 23/ 7/2022 13:52: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 35 15.19 506 269 0.27 / 51.15 4 10
2 7 2008.00 40 14.94 3457 2066 2.33 / 53.21 10 23
3 13 1916.32 20 14.93 3385 1011 3.35 / 54.22 4 27
4 13 1381.08 20 14.97 2628 787 4.13 / 55.01 4 34
5 13 849.08 20 15.06 1809 545 4.68 / 55.56 4 41
6 13 190.96 20 15.23 699 213 4.89 / 55.77 4 39
7 8 0.24 366 15.21 354 1971 6.86 / 57.74 4 150
Average= 19.25
(KJ/cycle)

Cycle 9 GMT 13/ 7/2022 16:22: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 36 15.21 511 280 0.28 / 44.16 5 7
2 3 954.80 -1 15.56 0 0 0.00 / 44.16 5 7
3 7 2002.96 40 14.95 3497 2091 2.37 / 46.25 7 24
4 13 1914.28 20 14.95 3374 1009 3.38 / 47.26 4 26
5 13 1488.16 20 14.96 2780 832 4.21 / 48.10 4 32
6 13 841.00 20 15.06 1803 543 4.75 / 48.64 4 40
7 13 399.16 20 15.17 1070 325 5.08 / 48.96 4 43
8 8 -0.28 361 15.21 349 1916 7.00 / 50.88 4 139
Average= 25.44
(KJ/cycle)

Cycle 8 GMT 3/ 7/2022 19: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.24 36 15.24 470 258 0.26 / 37.08 5 6
2 7 2022.52 40 14.94 3515 2101 2.36 / 39.18 4 23
3 13 1947.56 20 14.93 3403 1016 3.37 / 40.19 4 26
4 13 1514.20 20 14.94 2832 846 4.22 / 41.04 4 32
5 13 1176.92 20 14.97 2319 694 4.92 / 41.73 4 37
6 13 553.56 20 15.12 1324 400 5.32 / 42.13 4 42
7 8 0.04 336 15.22 342 1749 7.06 / 43.88 4 142
Average= 43.88
(KJ/cycle)

Cycle 6 GMT 14/ 6/2022 0:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 33 15.21 492 247 0.25 / 30.52 4 8
2 3 1074.52 2 15.25 2156 66 0.31 / 30.59 4 26
3 7 2010.88 40 14.97 3498 2095 2.41 / 32.68 26 24
4 13 1926.32 20 14.95 3385 1012 3.42 / 33.69 4 27
5 13 1315.44 20 15.00 2546 764 4.18 / 34.46 4 35
6 13 910.68 20 15.06 1889 569 4.75 / 35.03 4 39
7 13 264.12 20 15.24 794 242 4.99 / 35.27 4 31
8 13 12.64 20 15.30 360 110 5.10 / 35.38 4 23
9 8 -0.08 289 15.24 327 1440 6.54 / 36.82 4 167
Average= 5.26
(KJ/cycle)

Cycle 5 GMT 4/ 6/2022 2:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.76 31 15.20 503 237 0.24 / 23.75 4 10
2 3 1077.60 2 15.21 2198 67 0.30 / 23.82 4 31
3 7 2008.28 40 14.96 3486 2086 2.39 / 25.90 31 27
4 13 1926.24 20 14.96 3382 1012 3.40 / 26.92 4 28
5 13 1495.16 20 14.96 2787 834 4.24 / 27.75 4 34
6 13 933.40 20 15.05 1928 580 4.82 / 28.33 4 40
7 13 272.68 20 15.22 825 251 5.07 / 28.58 4 37
8 8 0.20 329 15.23 338 1694 6.76 / 30.27 4 132
Average= 5.05
(KJ/cycle)

Cycle 4 GMT 25/ 5/2022 5:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.88 33 15.20 499 250 0.25 / 17.89 5 10
2 7 1510.36 41 15.09 2783 1722 1.97 / 19.61 10 30
3 13 1442.40 20 15.07 2705 815 2.79 / 20.42 4 32
4 13 1347.00 20 15.03 2571 773 3.56 / 21.20 4 34
5 13 605.60 20 15.15 1410 427 3.99 / 21.62 4 42
6 13 19.60 20 15.30 392 120 4.11 / 21.74 4 29
7 8 0.16 336 15.23 346 1771 5.88 / 23.51 4 145
Average= 4.70
(KJ/cycle)

Cycle 3 GMT 23/ 5/2022 19:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 33 15.18 520 260 0.26 / 12.07 4 8
2 7 1520.84 40 15.08 2819 1700 1.96 / 13.77 7 27
3 13 1452.96 20 15.07 2711 817 2.78 / 14.59 4 30
4 13 1144.20 20 15.06 2265 682 3.46 / 15.27 4 36
5 13 633.04 20 15.14 1457 441 3.90 / 15.72 4 41
6 13 42.68 20 15.28 439 134 4.04 / 15.85 4 32
7 8 -0.08 338 15.23 347 1786 5.82 / 17.64 4 156
Average= 4.41
(KJ/cycle)

Cycle 2 GMT 22/ 5/2022 9: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 31 15.21 515 243 0.24 / 6.05 4 9
2 10 1028.24 3 15.23 2066 94 0.34 / 6.15 4 25
3 7 1509.92 40 15.09 2798 1689 2.03 / 7.84 25 30
4 13 1445.20 20 15.07 2711 817 2.84 / 8.65 4 32
5 13 1148.16 20 15.06 2270 684 3.53 / 9.34 4 36
6 13 717.52 20 15.12 1591 481 4.01 / 9.82 4 41
7 13 66.68 20 15.28 479 146 4.15 / 9.97 4 34
8 8 -0.12 345 15.22 352 1848 6.00 / 11.81 4 146
Average= 3.94
(KJ/cycle)

Cycle 1 GMT 20/ 5/2022 22:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 31 15.44 473 226 0.23 / 2.07 5 6
2 3 1042.68 1 15.29 2130 33 0.26 / 2.10 4 27
3 7 1034.64 40 15.17 2081 1263 1.52 / 3.37 27 34
4 13 715.44 20 15.21 1583 482 2.00 / 3.85 4 39
5 13 72.40 20 15.33 484 148 2.15 / 4.00 4 34
6 8 0.04 340 15.26 350 1816 3.97 / 5.81 4 175
Average= 2.91
(KJ/cycle)

Cycle 0 GMT 20/ 5/2022 12: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 69.28 30 15.61 407 191 0.19 / 0.19 5 5
2 7 78.76 41 15.59 416 266 0.46 / 0.46 5 8
3 13 53.44 20 15.58 378 118 0.57 / 0.57 5 7
4 8 0.16 285 15.52 287 1269 1.84 / 1.84 5 142
Average= 1.84
(KJ/cycle)