SIO Argo Site:
Pump Diagnostics Page   



Serial= 7530 WMO= 1902275

Return

←PreviousNext→

Cycle 137 GMT 2/ 5/2024 7:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 34 14.81 484 244 0.24 / 749.73 5 38
2 7 2016.20 40 14.44 3291 1901 2.14 / 751.63 38 67
3 13 1924.40 20 14.43 3170 915 3.06 / 752.55 5 71
4 13 1301.92 20 14.47 2307 668 3.73 / 753.21 5 84
5 13 977.24 20 14.50 1831 531 4.26 / 753.74 5 90
6 13 92.04 20 14.84 485 144 4.40 / 753.89 5 80
7 8 0.00 233 14.81 319 1101 5.50 / 754.99 5 138
Average= 11.10
(KJ/cycle)

Cycle 136 GMT 22/ 4/2024 10:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 34 14.81 481 242 0.24 / 744.13 5 36
2 7 2011.08 41 14.45 3282 1944 2.19 / 746.07 36 66
3 13 1935.28 20 14.42 3188 919 3.11 / 746.99 5 70
4 13 1322.48 20 14.45 2354 680 3.79 / 747.67 5 83
5 13 719.72 20 14.60 1456 425 4.21 / 748.09 5 90
6 13 405.80 20 14.70 983 289 4.50 / 748.38 5 90
7 8 -0.04 231 14.81 322 1102 5.60 / 749.49 5 131
Average= 11.19
(KJ/cycle)

Cycle 135 GMT 12/ 4/2024 13: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 34 14.82 492 248 0.25 / 738.25 5 36
2 7 2012.40 40 14.45 3273 1892 2.14 / 740.14 36 67
3 13 1916.36 20 14.44 3157 912 3.05 / 741.05 5 71
4 13 1706.32 20 14.40 2880 829 3.88 / 741.88 5 77
5 13 927.84 20 14.54 1759 512 4.39 / 742.39 5 91
6 13 591.68 20 14.63 1249 365 4.76 / 742.76 5 92
7 8 0.00 235 14.81 324 1128 5.89 / 743.88 5 132
Average= 11.27
(KJ/cycle)

Cycle 134 GMT 2/ 4/2024 16:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 34 14.83 469 236 0.24 / 732.64 5 33
2 7 2004.72 40 14.46 3272 1893 2.13 / 734.53 33 66
3 13 1823.92 20 14.44 3051 881 3.01 / 735.42 5 73
4 13 1519.68 20 14.43 2606 752 3.76 / 736.17 5 79
5 13 974.20 20 14.52 1826 530 4.29 / 736.70 5 89
6 13 187.56 20 14.80 639 189 4.48 / 736.89 5 81
7 8 0.08 235 14.82 319 1111 5.59 / 738.00 5 133
Average= 11.35
(KJ/cycle)

Cycle 133 GMT 23/ 3/2024 19:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 34 14.84 474 239 0.24 / 727.06 5 31
2 7 2005.48 40 14.45 3282 1897 2.14 / 728.96 31 66
3 13 1918.68 20 14.43 3168 914 3.05 / 729.87 5 71
4 13 1490.20 20 14.43 2582 745 3.80 / 730.62 5 81
5 13 923.68 20 14.53 1758 511 4.31 / 731.13 5 91
6 13 144.72 20 14.82 566 168 4.47 / 731.30 5 79
7 13 24.08 20 14.86 365 108 4.58 / 731.41 5 79
8 8 0.08 214 14.82 315 999 5.58 / 732.41 5 131
Average= 11.44
(KJ/cycle)

Cycle 132 GMT 13/ 3/2024 22:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.36 34 14.83 497 251 0.25 / 721.59 5 37
2 7 2003.32 40 14.46 3279 1897 2.15 / 723.49 37 67
3 13 1904.64 20 14.44 3155 911 3.06 / 724.40 5 72
4 13 1365.56 20 14.46 2405 696 3.75 / 725.09 5 83
5 13 836.12 20 14.56 1625 473 4.23 / 725.57 5 90
6 13 82.92 20 14.85 472 140 4.37 / 725.71 5 79
7 8 0.08 238 14.83 316 1115 5.48 / 726.82 5 135
Average= 11.54
(KJ/cycle)

Cycle 131 GMT 4/ 3/2024 1:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 34 14.82 467 235 0.24 / 716.06 5 34
2 7 2009.76 40 14.46 3265 1888 2.12 / 717.95 34 67
3 13 1918.32 20 14.45 3168 916 3.04 / 718.86 5 70
4 13 1403.84 20 14.46 2433 704 3.74 / 719.56 5 81
5 13 975.48 20 14.52 1828 531 4.27 / 720.10 5 89
6 13 108.32 20 14.84 505 150 4.42 / 720.25 5 80
7 8 0.16 236 14.83 313 1095 5.52 / 721.34 5 135
Average= 11.63
(KJ/cycle)

Cycle 130 GMT 23/ 2/2024 4: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.04 34 14.83 474 239 0.24 / 710.45 5 36
2 7 2005.84 40 14.46 3272 1893 2.13 / 712.35 36 66
3 13 1918.28 20 14.45 3161 914 3.05 / 713.26 5 70
4 13 1393.04 20 14.46 2441 706 3.75 / 713.97 5 83
5 13 960.96 20 14.52 1809 525 4.28 / 714.49 5 90
6 13 293.40 20 14.76 805 238 4.51 / 714.73 5 86
7 8 -0.08 231 14.82 319 1092 5.61 / 715.82 5 138
Average= 11.73
(KJ/cycle)

Cycle 129 GMT 13/ 2/2024 7: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.44 34 14.83 467 235 0.24 / 704.98 5 38
2 7 2005.24 40 14.46 3266 1889 2.12 / 706.87 38 67
3 13 1915.68 20 14.44 3137 906 3.03 / 707.78 5 70
4 13 1486.04 20 14.45 2562 740 3.77 / 708.52 5 79
5 13 842.88 20 14.57 1627 474 4.25 / 708.99 5 89
6 13 96.36 20 14.85 491 146 4.39 / 709.14 5 79
7 8 -0.08 229 14.83 318 1080 5.47 / 710.22 5 132
Average= 11.84
(KJ/cycle)

Cycle 128 GMT 3/ 2/2024 10: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 34 14.84 479 242 0.24 / 699.44 5 34
2 7 2011.16 40 14.47 3261 1887 2.13 / 701.33 34 66
3 13 1917.60 20 14.45 3152 911 3.04 / 702.24 5 71
4 13 1409.04 20 14.47 2441 706 3.75 / 702.94 5 82
5 13 993.00 20 14.51 1842 535 4.28 / 703.48 5 90
6 13 102.36 20 14.85 496 147 4.43 / 703.63 5 82
7 13 21.88 20 14.87 363 108 4.54 / 703.73 5 79
8 8 -0.08 217 14.83 314 1010 5.55 / 704.75 5 136
Average= 11.94
(KJ/cycle)

Cycle 127 GMT 24/ 1/2024 12:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 34 14.83 478 241 0.24 / 694.00 5 38
2 7 2004.48 40 14.46 3270 1891 2.13 / 695.89 38 66
3 13 1911.04 20 14.46 3155 912 3.04 / 696.80 5 71
4 13 1470.44 20 14.46 2539 734 3.78 / 697.54 5 81
5 13 718.08 20 14.62 1438 420 4.20 / 697.96 5 90
6 13 84.72 20 14.87 472 140 4.34 / 698.10 5 79
7 8 0.16 233 14.84 318 1100 5.44 / 699.20 5 129
Average= 12.06
(KJ/cycle)

Cycle 126 GMT 14/ 1/2024 15:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 35 14.83 497 258 0.26 / 688.37 5 42
2 7 2009.80 40 14.47 3274 1895 2.15 / 690.27 42 67
3 13 1932.76 20 14.45 3174 917 3.07 / 691.18 5 70
4 13 1424.36 20 14.46 2469 714 3.78 / 691.90 5 82
5 13 877.64 20 14.56 1685 491 4.27 / 692.39 5 90
6 13 313.64 20 14.76 832 246 4.52 / 692.63 5 90
7 8 0.16 233 14.82 326 1126 5.65 / 693.76 5 137
Average= 12.17
(KJ/cycle)

Cycle 125 GMT 4/ 1/2024 18:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 35 14.81 503 261 0.26 / 682.70 5 45
2 7 2005.60 40 14.47 3275 1896 2.16 / 684.60 45 67
3 13 1914.72 20 14.45 3182 920 3.08 / 685.52 5 72
4 13 1606.48 20 14.43 2742 791 3.87 / 686.31 5 80
5 13 836.52 20 14.59 1635 477 4.34 / 686.78 5 90
6 13 184.76 20 14.83 640 190 4.53 / 686.97 5 86
7 13 13.08 20 14.89 365 109 4.64 / 687.08 5 83
8 8 -0.16 208 14.83 334 1030 5.67 / 688.11 5 129
Average= 12.29
(KJ/cycle)

Cycle 124 GMT 25/12/2023 21:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 35 14.81 487 252 0.25 / 676.95 5 50
2 7 2005.72 40 14.46 3273 1893 2.15 / 678.84 50 68
3 13 1921.84 20 14.45 3164 914 3.06 / 679.76 5 71
4 13 1490.84 20 14.45 2569 742 3.80 / 680.50 5 82
5 13 941.72 20 14.55 1775 517 4.32 / 681.02 5 91
6 13 267.60 20 14.79 770 228 4.55 / 681.24 5 90
7 8 0.24 248 14.83 325 1195 5.74 / 682.44 5 129
Average= 12.41
(KJ/cycle)

Cycle 123 GMT 16/12/2023 0:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 35 14.81 494 256 0.26 / 671.22 5 51
2 7 2015.88 40 14.46 3293 1905 2.16 / 673.12 51 67
3 13 1925.32 20 14.45 3187 921 3.08 / 674.05 5 72
4 13 1396.32 20 14.47 2429 703 3.78 / 674.75 5 83
5 13 869.00 20 14.57 1669 486 4.27 / 675.23 5 92
6 13 308.04 20 14.77 842 249 4.52 / 675.48 5 92
7 8 0.24 248 14.83 330 1214 5.73 / 676.70 5 134
Average= 12.53
(KJ/cycle)

Cycle 122 GMT 6/12/2023 3:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 35 14.80 503 261 0.26 / 665.41 5 49
2 7 2015.40 40 14.47 3299 1909 2.17 / 667.32 49 67
3 13 1927.56 20 14.44 3201 924 3.09 / 668.24 5 71
4 13 1499.16 20 14.46 2585 748 3.84 / 668.99 5 82
5 13 762.00 20 14.62 1515 443 4.29 / 669.43 5 91
6 13 337.44 20 14.76 876 259 4.54 / 669.69 5 94
7 8 0.04 259 14.83 332 1275 5.82 / 670.96 5 134
Average= 12.66
(KJ/cycle)

Cycle 121 GMT 26/11/2023 6:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 35 14.81 508 263 0.26 / 659.50 5 49
2 7 2006.52 40 14.47 3290 1904 2.17 / 661.40 49 66
3 13 1914.28 20 14.45 3181 919 3.09 / 662.32 5 71
4 13 1498.92 20 14.46 2586 748 3.83 / 663.07 5 80
5 13 1060.32 20 14.51 1960 569 4.40 / 663.64 5 89
6 13 268.28 20 14.79 778 230 4.63 / 663.87 5 90
7 8 0.08 259 14.83 333 1279 5.91 / 665.15 5 129
Average= 12.79
(KJ/cycle)

Cycle 120 GMT 16/11/2023 9:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 35 14.81 504 261 0.26 / 653.66 5 48
2 7 2005.96 40 14.47 3291 1905 2.17 / 655.57 48 67
3 13 1921.04 20 14.46 3192 923 3.09 / 656.49 5 72
4 13 1501.36 20 14.46 2588 748 3.84 / 657.24 5 81
5 13 965.44 20 14.55 1812 527 4.36 / 657.76 5 90
6 13 200.76 20 14.83 661 196 4.56 / 657.96 5 86
7 8 -0.08 259 14.84 331 1272 5.83 / 659.23 5 133
Average= 12.93
(KJ/cycle)

Cycle 119 GMT 6/11/2023 12:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 35 14.83 502 261 0.26 / 647.72 5 47
2 7 2013.64 40 14.46 3302 1910 2.17 / 649.63 47 66
3 13 1919.88 20 14.46 3174 918 3.09 / 650.55 5 72
4 13 1492.72 20 14.46 2590 749 3.84 / 651.29 5 81
5 13 1054.24 20 14.51 1959 569 4.41 / 651.86 5 89
6 13 352.00 20 14.75 912 269 4.67 / 652.13 5 94
7 8 -0.08 253 14.82 338 1267 5.94 / 653.40 5 132
Average= 13.07
(KJ/cycle)

Cycle 118 GMT 27/10/2023 15:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 35 14.80 502 260 0.26 / 642.01 5 53
2 7 2014.68 40 14.47 3291 1905 2.16 / 643.92 53 67
3 13 1927.88 20 14.45 3194 923 3.09 / 644.84 5 71
4 13 1513.16 20 14.45 2624 758 3.85 / 645.60 5 81
5 13 832.36 20 14.60 1615 472 4.32 / 646.07 5 90
6 13 165.16 20 14.85 603 179 4.50 / 646.25 5 84
7 8 0.16 248 14.84 328 1207 5.70 / 647.46 5 130
Average= 13.21
(KJ/cycle)

Cycle 117 GMT 17/10/2023 18:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 35 14.82 508 263 0.26 / 636.11 5 52
2 7 2006.12 40 14.47 3275 1896 2.16 / 638.01 52 66
3 13 1919.88 20 14.45 3169 916 3.07 / 638.93 5 71
4 13 1396.48 20 14.47 2458 711 3.79 / 639.64 5 82
5 13 974.16 20 14.54 1847 537 4.32 / 640.17 5 89
6 13 402.36 20 14.73 994 293 4.62 / 640.47 5 93
7 8 -0.08 259 14.82 335 1286 5.90 / 641.75 5 132
Average= 13.37
(KJ/cycle)

Cycle 116 GMT 7/10/2023 21:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.92 35 14.83 511 265 0.27 / 630.35 5 53
2 7 2007.52 40 14.47 3279 1898 2.16 / 632.25 53 66
3 13 1927.60 20 14.45 3175 918 3.08 / 633.17 5 71
4 13 1500.84 20 14.46 2593 750 3.83 / 633.92 5 81
5 13 636.20 20 14.67 1327 389 4.22 / 634.31 5 93
6 13 324.64 20 14.78 861 255 4.47 / 634.56 5 92
7 8 0.32 259 14.83 335 1287 5.76 / 635.85 5 139
Average= 13.53
(KJ/cycle)

Cycle 115 GMT 28/ 9/2023 0:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.76 35 14.82 497 258 0.26 / 624.68 5 54
2 7 2007.72 40 14.47 3288 1903 2.16 / 626.58 54 66
3 13 1913.88 20 14.46 3165 915 3.08 / 627.50 5 71
4 13 1392.04 20 14.48 2443 707 3.78 / 628.21 5 83
5 13 854.36 20 14.59 1650 481 4.27 / 628.69 5 91
6 13 47.72 20 14.90 424 126 4.39 / 628.81 5 81
7 8 0.04 257 14.85 334 1275 5.67 / 630.09 5 139
Average= 13.70
(KJ/cycle)

Cycle 114 GMT 18/ 9/2023 3:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 35 14.83 511 265 0.27 / 618.92 5 52
2 3 1021.96 1 14.99 1947 29 0.29 / 618.95 5 21
3 7 2013.84 40 14.47 3290 1904 2.20 / 620.86 21 66
4 13 1935.72 20 14.45 3194 923 3.12 / 621.78 5 71
5 13 1424.76 20 14.47 2504 725 3.85 / 622.51 5 83
6 13 776.12 20 14.62 1534 449 4.29 / 622.95 5 92
7 13 221.28 20 14.82 696 206 4.50 / 623.16 5 87
8 8 0.28 257 14.84 331 1262 5.76 / 624.42 5 134
Average= 13.88
(KJ/cycle)

Cycle 113 GMT 8/ 9/2023 6:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.32 35 14.82 505 262 0.26 / 613.36 5 53
2 7 2005.68 40 14.48 3285 1903 2.16 / 615.26 53 67
3 13 1910.36 20 14.46 3164 915 3.08 / 616.18 5 71
4 13 1365.40 20 14.49 2416 700 3.78 / 616.88 5 84
5 13 642.44 20 14.67 1335 392 4.17 / 617.27 5 92
6 13 57.64 20 14.90 439 131 4.30 / 617.40 5 81
7 8 -0.08 255 14.85 332 1257 5.56 / 618.66 5 130
Average= 14.06
(KJ/cycle)

Cycle 112 GMT 29/ 8/2023 9:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 35 14.83 507 263 0.26 / 607.59 5 52
2 7 2014.56 40 14.47 3295 1907 2.17 / 609.49 52 66
3 13 1920.96 20 14.47 3168 917 3.09 / 610.41 5 71
4 13 1493.60 20 14.47 2585 748 3.84 / 611.16 5 80
5 13 842.80 20 14.59 1637 478 4.31 / 611.64 5 92
6 13 280.12 20 14.80 793 235 4.55 / 611.87 5 90
7 8 0.12 248 14.84 334 1229 5.78 / 613.10 5 132
Average= 14.26
(KJ/cycle)

Cycle 111 GMT 19/ 8/2023 11:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.24 35 14.82 494 256 0.26 / 601.77 5 51
2 3 1019.44 1 14.97 1961 29 0.29 / 601.80 5 19
3 7 2003.84 40 14.48 3285 1903 2.19 / 603.70 19 66
4 13 1909.80 20 14.46 3170 917 3.11 / 604.62 5 71
5 13 1603.44 20 14.44 2744 792 3.90 / 605.41 5 78
6 13 820.44 20 14.61 1614 472 4.37 / 605.89 5 92
7 13 80.44 20 14.89 483 144 4.51 / 606.03 5 82
8 8 -0.08 261 14.85 334 1295 5.81 / 607.32 5 130
Average= 14.46
(KJ/cycle)

Cycle 110 GMT 9/ 8/2023 14:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.12 35 14.83 487 253 0.25 / 596.02 5 49
2 7 2011.84 40 14.48 3279 1899 2.15 / 597.92 49 66
3 13 1933.12 20 14.46 3184 921 3.07 / 598.84 5 71
4 13 1487.36 20 14.47 2568 743 3.82 / 599.58 5 81
5 13 818.44 20 14.61 1597 467 4.28 / 600.05 5 90
6 13 163.44 20 14.85 600 178 4.46 / 600.23 5 86
7 8 -0.08 262 14.84 331 1287 5.75 / 601.52 5 133
Average= 14.67
(KJ/cycle)

Cycle 109 GMT 30/ 7/2023 17:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.20 35 14.83 492 255 0.26 / 590.43 5 49
2 7 2004.40 40 14.48 3293 1907 2.16 / 592.34 49 67
3 13 1914.32 20 14.46 3170 917 3.08 / 593.25 5 72
4 13 1388.60 20 14.49 2442 708 3.79 / 593.96 5 83
5 13 766.64 20 14.63 1531 448 4.24 / 594.41 5 91
6 13 120.60 20 14.87 543 161 4.40 / 594.57 5 82
7 8 0.16 242 14.85 333 1197 5.59 / 595.77 5 134
Average= 14.89
(KJ/cycle)

Cycle 108 GMT 20/ 7/2023 20:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 34 14.84 504 254 0.25 / 584.73 5 45
2 7 2015.16 41 14.47 3294 1954 2.21 / 586.68 20 67
3 13 1927.08 20 14.46 3185 921 3.13 / 587.61 5 71
4 13 1386.08 20 14.48 2434 705 3.83 / 588.31 5 81
5 13 857.60 20 14.60 1650 482 4.32 / 588.79 5 89
6 13 192.48 20 14.84 650 193 4.51 / 588.99 5 87
7 8 -0.08 242 14.85 331 1190 5.70 / 590.17 5 138
Average= 15.13
(KJ/cycle)

Cycle 107 GMT 10/ 7/2023 23:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.80 34 14.85 494 249 0.25 / 579.11 5 46
2 7 2006.20 40 14.48 3286 1903 2.15 / 581.01 46 66
3 13 1925.28 20 14.46 3176 918 3.07 / 581.93 5 70
4 13 1479.92 20 14.47 2562 741 3.81 / 582.67 5 81
5 13 733.88 20 14.65 1469 430 4.24 / 583.10 5 90
6 13 200.84 20 14.84 664 197 4.44 / 583.30 5 85
7 8 0.36 240 14.85 330 1176 5.62 / 584.48 5 142
Average= 15.38
(KJ/cycle)

Cycle 106 GMT 1/ 7/2023 2:35:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 35 14.84 495 257 0.26 / 573.57 5 44
2 7 2015.72 40 14.47 3286 1902 2.16 / 575.47 44 66
3 13 1922.60 20 14.47 3162 915 3.07 / 576.39 5 72
4 13 1381.20 20 14.49 2427 703 3.78 / 577.09 5 84
5 13 930.64 20 14.56 1766 514 4.29 / 577.60 5 91
6 13 78.60 20 14.89 463 138 4.43 / 577.74 5 83
7 8 0.08 231 14.86 326 1119 5.55 / 578.86 5 136
Average= 15.64
(KJ/cycle)

Cycle 105 GMT 21/ 6/2023 5:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.24 34 14.82 497 250 0.25 / 568.03 5 45
2 7 2016.88 40 14.48 3286 1903 2.15 / 569.94 20 66
3 13 1934.92 20 14.46 3178 919 3.07 / 570.86 5 71
4 13 1207.96 20 14.53 2176 632 3.71 / 571.49 5 85
5 13 888.80 20 14.58 1704 497 4.20 / 571.99 5 90
6 13 210.08 20 14.83 683 203 4.40 / 572.19 5 84
7 8 -0.08 227 14.85 333 1123 5.53 / 573.31 5 129
Average= 15.93
(KJ/cycle)

Cycle 104 GMT 11/ 6/2023 8:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 34 14.86 500 253 0.25 / 562.39 5 44
2 7 2014.24 40 14.48 3286 1903 2.16 / 564.29 7 66
3 13 1916.52 20 14.48 3156 914 3.07 / 565.20 5 71
4 13 1177.04 20 14.54 2126 618 3.69 / 565.82 5 86
5 13 982.28 20 14.55 1839 535 4.22 / 566.36 5 89
6 13 387.24 20 14.75 962 284 4.51 / 566.64 5 92
7 8 0.28 233 14.84 331 1145 5.65 / 567.78 5 132
Average= 16.22
(KJ/cycle)

Cycle 103 GMT 1/ 6/2023 11:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 34 14.85 493 249 0.25 / 556.62 5 42
2 7 2004.92 40 14.50 3252 1886 2.14 / 558.51 42 66
3 13 1813.76 20 14.49 3025 877 3.01 / 559.38 5 72
4 13 1620.64 20 14.45 2766 799 3.81 / 560.18 5 79
5 13 1062.20 20 14.53 1955 568 4.38 / 560.75 5 86
6 13 277.04 20 14.82 784 232 4.61 / 560.98 5 85
7 8 0.08 236 14.86 328 1150 5.76 / 562.13 5 134
Average= 16.53
(KJ/cycle)

Cycle 102 GMT 22/ 5/2023 14:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 34 14.86 500 253 0.25 / 550.95 5 43
2 7 2006.16 41 14.48 3284 1950 2.20 / 552.90 43 68
3 13 1818.60 20 14.49 3024 876 3.08 / 553.77 5 73
4 13 1414.56 20 14.48 2481 718 3.80 / 554.49 5 83
5 13 1072.76 20 14.52 1970 572 4.37 / 555.07 5 87
6 13 148.72 20 14.86 579 172 4.54 / 555.24 5 83
7 8 -0.20 234 14.86 326 1134 5.67 / 556.37 5 134
Average= 16.86
(KJ/cycle)

Cycle 101 GMT 12/ 5/2023 17:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 34 14.84 490 247 0.25 / 545.32 5 42
2 7 2007.20 40 14.48 3280 1900 2.15 / 547.22 42 66
3 13 1921.40 20 14.48 3174 919 3.07 / 548.14 5 70
4 13 1490.12 20 14.47 2588 749 3.82 / 548.89 5 81
5 13 1042.00 20 14.54 1945 566 4.38 / 549.45 5 88
6 13 71.84 20 14.90 466 139 4.52 / 549.59 5 79
7 8 0.16 225 14.87 330 1104 5.62 / 550.70 5 135
Average= 17.21
(KJ/cycle)

Cycle 100 GMT 2/ 5/2023 20:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.36 34 14.86 488 247 0.25 / 539.71 5 42
2 7 2004.32 40 14.49 3282 1902 2.15 / 541.61 42 65
3 13 1814.12 20 14.48 3042 881 3.03 / 542.49 5 73
4 13 1417.84 20 14.49 2472 716 3.75 / 543.21 5 81
5 13 861.08 20 14.61 1663 486 4.23 / 543.69 5 91
6 13 302.32 20 14.80 827 245 4.48 / 543.94 5 88
7 8 0.20 231 14.86 331 1136 5.61 / 545.07 5 129
Average= 17.58
(KJ/cycle)

Cycle 99 GMT 22/ 4/2023 23:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.20 34 14.86 497 251 0.25 / 534.06 5 38
2 7 2006.12 40 14.49 3289 1906 2.16 / 535.96 38 67
3 13 1913.88 20 14.47 3184 921 3.08 / 536.88 5 71
4 13 1478.28 20 14.47 2567 743 3.82 / 537.63 5 80
5 13 921.48 20 14.59 1750 511 4.33 / 538.14 5 89
6 13 154.16 20 14.87 588 175 4.51 / 538.31 5 82
7 13 13.36 20 14.92 358 107 4.61 / 538.42 5 80
8 8 -0.28 214 14.86 327 1040 5.65 / 539.46 5 140
Average= 17.98
(KJ/cycle)

Cycle 98 GMT 13/ 4/2023 2:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 34 14.86 497 251 0.25 / 528.47 5 36
2 7 2008.24 40 14.49 3285 1904 2.16 / 530.37 36 68
3 13 1820.20 20 14.48 3044 882 3.04 / 531.26 5 74
4 13 1513.08 20 14.47 2609 755 3.79 / 532.01 5 79
5 13 850.56 20 14.61 1642 480 4.27 / 532.49 5 92
6 13 197.60 20 14.85 651 193 4.46 / 532.68 5 84
7 8 0.12 232 14.87 325 1121 5.59 / 533.81 5 140
Average= 18.41
(KJ/cycle)

Cycle 97 GMT 3/ 4/2023 5: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 34 14.87 491 248 0.25 / 523.07 5 37
2 7 2009.40 40 14.49 3278 1900 2.15 / 524.97 37 66
3 13 1922.96 20 14.47 3176 919 3.07 / 525.89 5 71
4 13 1293.56 20 14.53 2289 665 3.73 / 526.56 5 83
5 13 671.40 20 14.67 1379 405 4.14 / 526.96 5 91
6 13 66.96 20 14.90 446 133 4.27 / 527.09 5 82
7 8 0.04 233 14.87 325 1126 5.40 / 528.22 5 132
Average= 18.86
(KJ/cycle)

Cycle 96 GMT 24/ 3/2023 7:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 34 14.86 494 250 0.25 / 517.46 5 35
2 7 2003.96 40 14.49 3296 1910 2.16 / 519.37 35 67
3 13 1905.56 20 14.48 3159 915 3.07 / 520.28 5 72
4 13 1569.00 20 14.47 2692 779 3.85 / 521.06 5 79
5 13 896.16 20 14.60 1712 500 4.35 / 521.56 5 90
6 13 57.64 20 14.93 436 130 4.48 / 521.69 5 78
7 8 0.12 234 14.89 325 1132 5.62 / 522.82 5 133
Average= 19.36
(KJ/cycle)

Cycle 95 GMT 14/ 3/2023 10:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 34 14.87 486 246 0.25 / 511.88 5 32
2 7 2006.32 40 14.49 3284 1903 2.15 / 513.78 32 66
3 13 1916.12 20 14.48 3164 916 3.07 / 514.70 5 70
4 13 1396.84 20 14.49 2447 709 3.77 / 515.41 5 81
5 13 849.84 20 14.61 1641 480 4.25 / 515.89 5 90
6 13 179.48 20 14.86 625 186 4.44 / 516.07 5 81
7 8 0.04 236 14.87 323 1134 5.57 / 517.21 5 136
Average= 19.89
(KJ/cycle)

Cycle 94 GMT 4/ 3/2023 13:46: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.92 34 14.88 484 245 0.24 / 506.10 5 35
2 7 2014.68 40 14.49 3301 1913 2.16 / 508.01 35 67
3 13 1942.52 20 14.48 3198 926 3.08 / 508.94 5 70
4 13 1522.28 20 14.46 2647 766 3.85 / 509.70 5 80
5 13 1089.16 20 14.53 2010 584 4.43 / 510.29 5 86
6 13 188.36 20 14.86 643 191 4.62 / 510.48 5 81
7 8 0.12 238 14.87 326 1154 5.78 / 511.63 5 129
Average= 20.47
(KJ/cycle)

Cycle 93 GMT 22/ 2/2023 16:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.56 34 14.89 477 241 0.24 / 500.44 5 33
2 7 2006.84 40 14.50 3265 1894 2.14 / 502.34 33 67
3 13 1911.00 20 14.49 3162 916 3.05 / 503.25 5 73
4 13 1698.00 20 14.44 2873 830 3.88 / 504.08 5 77
5 13 817.40 20 14.64 1594 467 4.35 / 504.55 5 90
6 13 189.32 20 14.87 640 190 4.54 / 504.74 5 79
7 8 0.04 233 14.88 321 1113 5.65 / 505.85 5 134
Average= 21.08
(KJ/cycle)

Cycle 92 GMT 12/ 2/2023 19:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 34 14.88 493 249 0.25 / 494.89 5 34
2 7 2005.20 40 14.50 3288 1907 2.16 / 496.80 34 67
3 13 1918.80 20 14.48 3174 919 3.08 / 497.72 5 71
4 13 1498.00 20 14.48 2585 749 3.82 / 498.46 5 80
5 13 852.08 20 14.62 1644 481 4.30 / 498.94 5 89
6 13 93.92 20 14.91 489 146 4.45 / 499.09 5 76
7 8 0.12 235 14.89 318 1113 5.56 / 500.20 5 134
Average= 21.75
(KJ/cycle)

Cycle 91 GMT 2/ 2/2023 22:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.16 33 14.89 482 237 0.24 / 489.47 5 35
2 7 2010.28 40 14.50 3289 1908 2.14 / 491.38 35 66
3 13 1824.48 20 14.49 3063 888 3.03 / 492.27 5 72
4 13 1320.68 20 14.51 2351 682 3.71 / 492.95 5 84
5 13 713.32 20 14.67 1445 424 4.14 / 493.37 5 91
6 13 83.60 20 14.91 478 143 4.28 / 493.52 5 78
7 8 0.08 231 14.88 327 1124 5.40 / 494.64 5 132
Average= 22.48
(KJ/cycle)

Cycle 90 GMT 24/ 1/2023 1:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 33 14.88 490 241 0.24 / 483.93 5 39
2 7 2012.48 40 14.49 3306 1916 2.16 / 485.84 39 66
3 13 1922.36 20 14.48 3188 923 3.08 / 486.77 5 71
4 13 1394.80 20 14.50 2453 711 3.79 / 487.48 5 82
5 13 863.48 20 14.61 1676 490 4.28 / 487.97 5 90
6 13 96.84 20 14.91 504 150 4.43 / 488.12 5 79
7 8 0.08 229 14.89 328 1118 5.55 / 489.24 5 133
Average= 23.30
(KJ/cycle)

Cycle 89 GMT 14/ 1/2023 4:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 34 14.88 485 245 0.25 / 478.37 5 39
2 7 2003.60 40 14.50 3281 1903 2.15 / 480.28 39 67
3 13 1906.48 20 14.48 3146 911 3.06 / 481.19 5 70
4 13 1483.24 20 14.49 2567 744 3.80 / 481.93 5 81
5 13 819.40 20 14.63 1603 469 4.27 / 482.40 5 92
6 13 148.12 20 14.89 579 172 4.44 / 482.57 5 85
7 8 -0.08 229 14.89 326 1112 5.56 / 483.69 5 129
Average= 24.18
(KJ/cycle)

Cycle 88 GMT 4/ 1/2023 7:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 34 14.88 494 250 0.25 / 472.70 5 39
2 7 2003.44 41 14.49 3290 1955 2.20 / 474.66 39 68
3 13 1906.64 20 14.49 3143 911 3.12 / 475.57 5 72
4 13 1386.80 20 14.51 2437 707 3.82 / 476.28 5 83
5 13 1053.16 20 14.55 1945 566 4.39 / 476.84 5 88
6 13 149.96 20 14.89 587 175 4.56 / 477.02 5 84
7 8 0.28 227 14.88 329 1111 5.67 / 478.13 5 132
Average= 25.16
(KJ/cycle)

Cycle 87 GMT 25/12/2022 10:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.12 34 14.88 492 249 0.25 / 467.09 5 39
2 7 2004.36 41 14.50 3287 1954 2.20 / 469.05 39 66
3 13 1914.20 20 14.49 3167 918 3.12 / 469.96 5 72
4 13 1488.84 20 14.49 2580 748 3.87 / 470.71 5 81
5 13 832.48 20 14.64 1626 476 4.34 / 471.19 5 90
6 13 80.52 20 14.92 470 140 4.48 / 471.33 5 81
7 8 -0.12 232 14.89 326 1126 5.61 / 472.45 5 131
Average= 26.25
(KJ/cycle)

Cycle 86 GMT 15/12/2022 13:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 34 14.88 495 250 0.25 / 461.37 5 40
2 7 2006.40 40 14.51 3285 1907 2.16 / 463.27 40 68
3 13 1919.04 20 14.49 3168 918 3.08 / 464.19 5 71
4 13 1496.92 20 14.49 2597 753 3.83 / 464.94 5 81
5 13 1149.80 20 14.53 2089 607 4.43 / 465.55 5 87
6 13 114.28 20 14.91 528 157 4.59 / 465.71 5 82
7 8 0.08 233 14.89 327 1134 5.73 / 466.84 5 129
Average= 27.46
(KJ/cycle)

Cycle 85 GMT 5/12/2022 16:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.64 34 14.88 495 250 0.25 / 455.79 5 43
2 7 2011.16 40 14.50 3287 1906 2.16 / 457.70 43 66
3 13 1912.64 20 14.49 3165 917 3.07 / 458.61 5 72
4 13 1374.28 20 14.52 2423 704 3.78 / 459.32 5 84
5 13 943.80 20 14.60 1781 520 4.30 / 459.84 5 90
6 13 77.32 20 14.92 470 140 4.44 / 459.98 5 80
7 8 -0.12 233 14.89 328 1138 5.58 / 461.12 5 132
Average= 28.82
(KJ/cycle)

Cycle 84 GMT 25/11/2022 19: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 34 14.87 495 250 0.25 / 450.28 5 42
2 7 2014.60 40 14.49 3297 1911 2.16 / 452.19 42 68
3 13 1929.64 20 14.50 3198 927 3.09 / 453.12 5 71
4 13 1311.72 20 14.52 2336 678 3.77 / 453.79 5 83
5 13 799.52 20 14.64 1585 464 4.23 / 454.26 5 89
6 13 36.00 20 14.94 411 123 4.35 / 454.38 5 80
7 8 0.16 231 14.89 337 1159 5.51 / 455.54 5 133
Average= 30.37
(KJ/cycle)

Cycle 83 GMT 15/11/2022 21:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.40 34 14.87 498 252 0.25 / 444.53 5 45
2 7 2014.52 40 14.51 3301 1916 2.17 / 446.44 45 67
3 13 1929.88 20 14.49 3194 926 3.09 / 447.37 5 72
4 13 1512.28 20 14.49 2618 759 3.85 / 448.13 5 80
5 13 829.00 20 14.64 1626 476 4.33 / 448.60 5 91
6 13 283.04 20 14.84 799 237 4.57 / 448.84 5 88
7 8 0.04 235 14.89 339 1186 5.75 / 450.03 5 135
Average= 32.14
(KJ/cycle)

Cycle 82 GMT 6/11/2022 0:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 34 14.88 505 255 0.26 / 438.78 5 46
2 7 2006.76 40 14.51 3277 1902 2.16 / 440.68 46 66
3 13 1908.20 20 14.50 3148 913 3.07 / 441.60 5 72
4 13 1580.56 20 14.48 2715 786 3.86 / 442.38 5 79
5 13 910.00 20 14.61 1745 510 4.37 / 442.89 5 90
6 13 248.88 20 14.86 745 221 4.59 / 443.11 5 87
7 8 0.08 235 14.89 332 1162 5.75 / 444.28 5 130
Average= 34.18
(KJ/cycle)

Cycle 81 GMT 27/10/2022 3:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 34 14.88 497 251 0.25 / 433.21 5 48
2 7 2004.60 40 14.52 3270 1899 2.15 / 435.11 48 67
3 13 1915.52 20 14.49 3171 919 3.07 / 436.03 5 72
4 13 1490.64 20 14.51 2567 745 3.81 / 436.77 5 80
5 13 739.52 20 14.69 1475 433 4.25 / 437.20 5 91
6 13 94.92 20 14.93 496 148 4.40 / 437.35 5 81
7 8 0.12 238 14.90 331 1174 5.57 / 438.53 5 136
Average= 36.54
(KJ/cycle)

Cycle 80 GMT 17/10/2022 6:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 34 14.89 504 255 0.26 / 427.78 5 47
2 7 2009.80 40 14.51 3292 1911 2.17 / 429.69 47 66
3 13 1821.48 20 14.51 3065 889 3.06 / 430.58 5 72
4 13 1319.32 20 14.54 2342 681 3.74 / 431.26 5 84
5 13 677.80 20 14.70 1389 408 4.14 / 431.67 5 91
6 13 125.32 20 14.91 542 162 4.31 / 431.83 5 82
7 8 0.08 229 14.90 329 1123 5.43 / 432.96 5 136
Average= 39.36
(KJ/cycle)

Cycle 79 GMT 7/10/2022 9:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 34 14.89 497 252 0.25 / 422.17 5 49
2 7 2004.12 40 14.52 3268 1898 2.15 / 424.06 49 68
3 13 1909.60 20 14.51 3155 916 3.07 / 424.98 5 73
4 13 1592.48 20 14.49 2719 788 3.85 / 425.77 5 77
5 13 831.64 20 14.66 1607 471 4.32 / 426.24 5 92
6 13 82.16 20 14.94 468 140 4.46 / 426.38 5 81
7 8 0.04 235 14.91 328 1149 5.61 / 427.53 5 134
Average= 42.75
(KJ/cycle)

Cycle 78 GMT 27/ 9/2022 12:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 34 14.89 497 252 0.25 / 416.52 5 48
2 7 2011.60 40 14.51 3313 1923 2.17 / 418.44 7 66
3 13 1921.88 20 14.49 3196 926 3.10 / 419.37 5 72
4 13 1500.16 20 14.50 2603 755 3.86 / 420.13 5 81
5 13 871.48 20 14.64 1681 492 4.35 / 420.62 5 91
6 13 56.68 20 14.95 432 129 4.48 / 420.75 5 79
7 8 0.04 238 14.91 329 1167 5.64 / 421.91 5 135
Average= 46.88
(KJ/cycle)

Cycle 77 GMT 17/ 9/2022 15:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 34 14.89 498 252 0.25 / 410.95 5 48
2 7 2007.16 40 14.51 3289 1909 2.16 / 412.86 48 67
3 13 1919.12 20 14.50 3182 923 3.08 / 413.78 5 72
4 13 1497.40 20 14.50 2603 755 3.84 / 414.53 5 82
5 13 752.40 20 14.69 1499 440 4.28 / 414.97 5 90
6 13 107.36 20 14.94 514 154 4.43 / 415.13 5 80
7 8 0.12 233 14.91 329 1143 5.58 / 416.27 5 136
Average= 52.03
(KJ/cycle)

Cycle 76 GMT 7/ 9/2022 18:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.00 34 14.90 484 245 0.25 / 405.40 5 47
2 7 2003.44 40 14.52 3259 1893 2.14 / 407.29 47 67
3 13 1913.20 20 14.52 3152 915 3.05 / 408.20 5 72
4 13 1379.76 20 14.54 2413 702 3.76 / 408.91 5 82
5 13 1043.84 20 14.57 1929 562 4.32 / 409.47 5 90
6 13 15.88 20 14.96 367 110 4.43 / 409.58 5 78
7 8 0.00 227 14.91 330 1117 5.54 / 410.69 5 131
Average= 58.67
(KJ/cycle)

Cycle 75 GMT 28/ 8/2022 21:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 34 14.90 497 252 0.25 / 399.86 5 45
2 7 2011.48 40 14.51 3313 1923 2.17 / 401.78 45 67
3 13 1926.28 20 14.50 3174 920 3.10 / 402.70 5 71
4 13 1398.04 20 14.52 2449 711 3.81 / 403.41 5 83
5 13 865.28 20 14.64 1673 490 4.30 / 403.90 5 92
6 13 49.92 20 14.96 414 124 4.42 / 404.03 5 78
7 8 0.00 232 14.91 325 1124 5.54 / 405.15 5 134
Average= 67.53
(KJ/cycle)

Cycle 74 GMT 19/ 8/2022 0: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.56 34 14.91 493 250 0.25 / 394.21 5 43
2 7 2003.28 40 14.53 3272 1902 2.15 / 396.11 43 66
3 13 1915.00 20 14.52 3156 917 3.07 / 397.03 5 71
4 13 1501.24 20 14.52 2600 755 3.82 / 397.78 5 79
5 13 953.52 20 14.62 1798 526 4.35 / 398.31 5 89
6 13 101.04 20 14.94 502 150 4.50 / 398.46 5 76
7 8 0.28 236 14.92 326 1148 5.65 / 399.61 5 133
Average= 79.92
(KJ/cycle)

Cycle 73 GMT 9/ 8/2022 2:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 34 14.91 491 249 0.25 / 388.57 5 44
2 7 2007.44 40 14.52 3261 1894 2.14 / 390.47 44 67
3 13 1923.88 20 14.51 3181 923 3.07 / 391.39 5 71
4 13 1500.16 20 14.50 2596 753 3.82 / 392.14 5 81
5 13 955.04 20 14.61 1808 528 4.35 / 392.67 5 89
6 13 175.40 20 14.91 625 186 4.53 / 392.86 5 78
7 8 -0.08 225 14.91 328 1100 5.63 / 393.96 5 130
Average= 98.49
(KJ/cycle)

Cycle 72 GMT 30/ 7/2022 5:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 34 14.91 505 256 0.26 / 383.04 5 43
2 7 2006.48 40 14.52 3283 1907 2.16 / 384.95 43 66
3 13 1920.28 20 14.52 3152 915 3.08 / 385.87 5 71
4 13 1405.36 20 14.53 2446 711 3.79 / 386.58 5 81
5 13 875.96 20 14.65 1674 490 4.28 / 387.07 5 91
6 13 50.52 20 14.97 415 124 4.40 / 387.19 5 74
7 8 0.16 235 14.93 323 1133 5.54 / 388.33 5 130
Average= 129.44
(KJ/cycle)

Cycle 71 GMT 20/ 7/2022 8:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.64 34 14.92 500 254 0.25 / 377.42 5 43
2 7 2006.00 40 14.53 3265 1898 2.15 / 379.32 43 67
3 13 1918.20 20 14.52 3160 918 3.07 / 380.24 5 72
4 13 1500.68 20 14.52 2600 755 3.82 / 380.99 5 80
5 13 867.08 20 14.66 1673 491 4.31 / 381.48 5 89
6 13 118.32 20 14.95 532 159 4.47 / 381.64 5 77
7 8 0.20 233 14.93 330 1148 5.62 / 382.79 5 131
Average= 191.39
(KJ/cycle)

Cycle 70 GMT 10/ 7/2022 11:19:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 34 14.92 504 256 0.26 / 371.62 5 42
2 7 2014.24 40 14.53 3303 1920 2.18 / 373.54 42 67
3 13 1921.80 20 14.52 3190 926 3.10 / 374.47 5 69
4 13 1498.28 20 14.52 2595 754 3.86 / 375.22 5 79
5 13 843.64 20 14.67 1648 484 4.34 / 375.70 5 91
6 13 413.92 20 14.82 996 295 4.63 / 376.00 5 89
7 8 0.20 235 14.92 333 1168 5.80 / 377.17 5 131
Average= 377.17
(KJ/cycle)

Cycle 68 GMT 20/ 6/2022 16:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.68 33 14.91 491 242 0.24 / 366.06 5 40
2 3 1023.96 1 15.03 1954 29 0.27 / 366.09 5 30
3 7 2006.72 40 14.54 3284 1910 2.18 / 368.00 30 67
4 13 1916.32 20 14.52 3180 923 3.10 / 368.93 5 72
5 13 1408.56 20 14.55 2467 718 3.82 / 369.64 5 82
6 13 761.68 20 14.71 1518 447 4.27 / 370.09 5 90
7 13 54.60 20 14.98 440 132 4.40 / 370.22 5 77
8 8 0.28 229 14.94 334 1143 5.54 / 371.37 5 129
Average= 5.38
(KJ/cycle)

Cycle 67 GMT 10/ 6/2022 19:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 33 14.94 490 242 0.24 / 360.47 5 39
2 7 2006.08 40 14.54 3285 1911 2.15 / 362.39 39 66
3 13 1920.00 20 14.52 3162 918 3.07 / 363.30 5 72
4 13 1291.84 20 14.57 2297 669 3.74 / 363.97 5 83
5 13 774.64 20 14.69 1526 448 4.19 / 364.42 5 92
6 13 338.56 20 14.85 876 260 4.45 / 364.68 5 87
7 8 -0.24 233 14.92 328 1140 5.59 / 365.82 5 132
Average= 5.38
(KJ/cycle)

Cycle 66 GMT 31/ 5/2022 22:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 33 14.93 500 246 0.25 / 354.88 5 40
2 7 2009.08 41 14.54 3282 1957 2.20 / 356.83 40 65
3 13 1925.16 20 14.52 3200 929 3.13 / 357.76 5 71
4 13 1391.44 20 14.55 2445 711 3.84 / 358.47 5 82
5 13 951.56 20 14.63 1796 526 4.37 / 359.00 5 92
6 13 81.08 20 14.97 474 142 4.51 / 359.14 5 78
7 8 0.16 225 14.94 325 1092 5.60 / 360.23 5 150
Average= 5.38
(KJ/cycle)

Cycle 65 GMT 22/ 5/2022 1:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 33 14.95 479 236 0.24 / 349.17 5 37
2 7 2004.04 40 14.55 3286 1912 2.15 / 351.09 37 66
3 13 1914.08 20 14.54 3162 920 3.07 / 352.01 5 71
4 13 1500.40 20 14.54 2611 759 3.83 / 352.76 5 80
5 13 953.04 20 14.64 1795 526 4.35 / 353.29 5 91
6 13 165.32 20 14.94 603 180 4.53 / 353.47 5 80
7 8 -0.08 238 14.94 326 1159 5.69 / 354.63 5 134
Average= 5.37
(KJ/cycle)

Cycle 64 GMT 12/ 5/2022 4:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 33 14.94 496 245 0.24 / 343.46 5 34
2 7 2004.56 40 14.54 3297 1918 2.16 / 345.38 34 67
3 13 1911.96 20 14.54 3177 924 3.09 / 346.30 5 72
4 13 1599.24 20 14.53 2729 793 3.88 / 347.09 5 79
5 13 1027.12 20 14.62 1913 559 4.44 / 347.65 5 89
6 13 76.60 20 14.99 462 139 4.58 / 347.79 5 74
7 8 0.08 240 14.96 319 1145 5.72 / 348.94 5 129
Average= 5.37
(KJ/cycle)

Cycle 63 GMT 2/ 5/2022 7:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.04 33 14.96 479 236 0.24 / 337.79 5 36
2 7 2018.24 40 14.55 3306 1924 2.16 / 339.71 36 66
3 13 1933.60 20 14.53 3183 925 3.09 / 340.64 5 72
4 13 1515.16 20 14.53 2620 761 3.85 / 341.40 5 81
5 13 755.20 20 14.72 1504 443 4.29 / 341.84 5 90
6 13 312.08 20 14.89 832 248 4.54 / 342.09 5 84
7 8 -0.12 235 14.95 321 1128 5.67 / 343.22 5 133
Average= 5.36
(KJ/cycle)

Cycle 62 GMT 22/ 4/2022 10:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 33 14.97 492 243 0.24 / 332.30 5 30
2 7 2007.08 40 14.55 3275 1906 2.15 / 334.21 30 66
3 13 1912.68 20 14.53 3177 923 3.07 / 335.13 5 71
4 13 1263.68 20 14.60 2269 663 3.73 / 335.79 5 84
5 13 847.60 20 14.69 1647 484 4.22 / 336.28 5 89
6 13 95.80 20 14.99 493 148 4.37 / 336.42 5 76
7 8 0.20 236 14.96 319 1126 5.49 / 337.55 5 131
Average= 5.36
(KJ/cycle)

Cycle 61 GMT 12/ 4/2022 13: 1: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 33 14.98 481 238 0.24 / 326.75 5 32
2 7 2017.04 40 14.55 3293 1917 2.15 / 328.67 32 63
3 13 1936.28 20 14.53 3199 930 3.08 / 329.60 5 71
4 13 1383.00 20 14.57 2435 710 3.79 / 330.31 5 82
5 13 856.92 20 14.70 1649 485 4.28 / 330.79 5 91
6 13 81.88 20 15.00 470 141 4.42 / 330.93 5 76
7 8 0.20 235 14.97 320 1126 5.55 / 332.06 5 131
Average= 5.36
(KJ/cycle)

Cycle 60 GMT 2/ 4/2022 15:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 33 14.98 481 238 0.24 / 321.05 5 30
2 7 2007.72 40 14.55 3273 1905 2.14 / 322.96 30 64
3 13 1921.32 20 14.54 3182 925 3.07 / 323.88 5 70
4 13 1598.92 20 14.53 2747 798 3.87 / 324.68 5 78
5 13 1037.08 20 14.64 1914 560 4.43 / 325.24 5 89
6 13 147.28 20 14.99 571 171 4.60 / 325.41 5 74
7 8 0.12 233 14.98 315 1099 5.70 / 326.51 5 132
Average= 5.35
(KJ/cycle)

Cycle 59 GMT 23/ 3/2022 19: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 33 14.99 487 241 0.24 / 315.41 5 30
2 7 2006.92 40 14.56 3285 1913 2.15 / 317.32 30 65
3 13 1925.28 20 14.55 3179 925 3.08 / 318.25 5 70
4 13 1413.36 20 14.58 2469 720 3.80 / 318.97 5 81
5 13 963.88 20 14.67 1824 535 4.33 / 319.50 5 89
6 13 147.04 20 14.99 574 172 4.51 / 319.67 5 75
7 8 0.04 240 14.98 317 1140 5.65 / 320.81 5 133
Average= 5.35
(KJ/cycle)

Cycle 58 GMT 13/ 3/2022 22: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.92 33 15.00 486 241 0.24 / 309.84 5 30
2 7 2004.92 41 14.56 3279 1957 2.20 / 311.80 30 65
3 13 1913.12 20 14.53 3180 924 3.12 / 312.73 5 71
4 13 1387.12 20 14.58 2443 712 3.83 / 313.44 5 83
5 13 833.08 20 14.73 1610 474 4.31 / 313.91 5 89
6 13 80.20 20 15.02 465 140 4.45 / 314.05 5 77
7 8 0.08 235 14.99 317 1117 5.57 / 315.17 5 137
Average= 5.34
(KJ/cycle)

Cycle 57 GMT 4/ 3/2022 1: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.36 33 15.00 485 240 0.24 / 304.67 5 26
2 7 1731.96 40 14.66 2900 1701 1.94 / 306.37 26 73
3 13 1653.96 20 14.65 2805 822 2.76 / 307.19 5 78
4 13 1451.56 20 14.63 2517 736 3.50 / 307.93 5 81
5 13 671.36 20 14.82 1362 404 3.90 / 308.33 5 89
6 13 60.32 20 15.04 433 130 4.03 / 308.46 5 74
7 8 0.16 238 15.01 319 1140 5.17 / 309.60 5 137
Average= 5.34
(KJ/cycle)

Cycle 56 GMT 22/ 2/2022 1: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.36 33 15.01 490 243 0.24 / 299.40 5 26
2 7 1794.92 41 14.64 2983 1791 2.03 / 301.19 8 72
3 13 1718.76 20 14.62 2906 850 2.88 / 302.04 5 75
4 13 1302.48 20 14.64 2320 679 3.56 / 302.72 5 85
5 13 754.52 20 14.77 1511 446 4.01 / 303.16 5 90
6 13 40.00 20 15.05 405 122 4.13 / 303.29 5 73
7 8 0.00 236 15.01 323 1144 5.27 / 304.43 5 135
Average= 5.34
(KJ/cycle)

Cycle 55 GMT 12/ 2/2022 0:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.76 33 15.01 470 233 0.23 / 293.85 5 28
2 7 2003.24 40 14.57 3271 1906 2.14 / 295.76 28 66
3 13 1905.72 20 14.57 3140 915 3.05 / 296.67 5 71
4 13 1391.80 20 14.60 2437 712 3.77 / 297.39 5 81
5 13 954.64 20 14.69 1792 526 4.29 / 297.91 5 90
6 13 79.84 20 15.04 464 140 4.43 / 298.05 5 76
7 8 0.12 235 15.02 313 1105 5.54 / 299.16 5 136
Average= 5.34
(KJ/cycle)

Cycle 54 GMT 2/ 2/2022 3:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 32 15.04 478 230 0.23 / 288.39 5 30
2 3 1031.00 1 15.09 1937 29 0.26 / 288.42 5 46
3 7 1799.52 40 14.64 3005 1760 2.02 / 290.18 46 71
4 13 1718.60 20 14.63 2897 848 2.87 / 291.02 5 77
5 13 1521.12 20 14.61 2620 766 3.63 / 291.79 5 81
6 13 939.24 20 14.73 1774 523 4.15 / 292.31 5 89
7 13 132.56 20 15.03 546 164 4.32 / 292.48 5 72
8 8 -0.12 240 15.02 317 1143 5.46 / 293.62 5 138
Average= 5.34
(KJ/cycle)

Cycle 53 GMT 23/ 1/2022 3:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 32 15.02 489 235 0.24 / 282.80 5 34
2 7 2003.00 40 14.58 3261 1902 2.14 / 284.70 34 67
3 13 1912.24 20 14.57 3164 922 3.06 / 285.62 5 70
4 13 1490.56 20 14.59 2579 753 3.81 / 286.37 5 81
5 13 951.12 20 14.72 1788 526 4.34 / 286.90 5 90
6 13 88.44 20 15.06 474 143 4.48 / 287.04 5 75
7 8 0.16 238 15.04 312 1117 5.60 / 288.16 5 137
Average= 5.34
(KJ/cycle)

Cycle 52 GMT 13/ 1/2022 6:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.36 32 15.03 492 237 0.24 / 277.16 5 32
2 7 2005.68 40 14.57 3270 1906 2.14 / 279.06 32 68
3 13 1911.64 20 14.57 3145 916 3.06 / 279.98 5 72
4 13 1367.92 20 14.63 2403 703 3.76 / 280.68 5 84
5 13 809.28 20 14.78 1584 468 4.23 / 281.15 5 92
6 13 369.64 20 14.94 922 275 4.51 / 281.43 5 90
7 8 0.08 233 15.03 324 1135 5.64 / 282.56 5 130
Average= 5.33
(KJ/cycle)

Cycle 51 GMT 3/ 1/2022 10: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 32 15.04 492 237 0.24 / 271.65 5 32
2 7 2005.92 40 14.58 3272 1908 2.15 / 273.56 32 67
3 13 1922.80 20 14.56 3171 923 3.07 / 274.48 5 72
4 13 1387.08 20 14.63 2425 710 3.78 / 275.19 5 83
5 13 744.24 20 14.81 1485 440 4.22 / 275.63 5 90
6 13 100.24 20 15.06 499 150 4.37 / 275.78 5 80
7 8 0.12 235 15.04 322 1138 5.51 / 276.92 5 133
Average= 5.33
(KJ/cycle)

Cycle 50 GMT 24/12/2021 12:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.52 32 15.04 482 232 0.23 / 266.18 5 34
2 7 2008.64 40 14.58 3284 1915 2.15 / 268.10 34 68
3 13 1819.60 20 14.59 3046 889 3.04 / 268.99 5 73
4 13 1307.44 20 14.65 2328 682 3.72 / 269.67 5 86
5 13 787.88 20 14.81 1539 456 4.17 / 270.13 5 91
6 13 122.68 20 15.05 532 160 4.33 / 270.29 5 82
7 8 0.08 235 15.05 319 1128 5.46 / 271.41 5 132
Average= 5.32
(KJ/cycle)

Cycle 49 GMT 14/12/2021 15:30:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 32 15.04 491 236 0.24 / 260.65 5 38
2 7 2008.96 40 14.58 3278 1912 2.15 / 262.57 38 67
3 13 1917.40 20 14.57 3157 920 3.07 / 263.49 5 72
4 13 1387.88 20 14.64 2428 711 3.78 / 264.20 5 84
5 13 837.12 20 14.78 1626 481 4.26 / 264.68 5 92
6 13 78.52 20 15.08 469 141 4.40 / 264.82 5 82
7 8 0.00 231 15.05 326 1133 5.53 / 265.95 5 131
Average= 5.32
(KJ/cycle)

Cycle 48 GMT 4/12/2021 18:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.08 33 15.04 489 243 0.24 / 254.84 5 40
2 7 2009.56 40 14.59 3273 1910 2.15 / 256.75 40 67
3 13 1916.44 20 14.59 3165 924 3.08 / 257.68 5 72
4 13 1585.56 20 14.59 2714 792 3.87 / 258.47 5 80
5 13 1009.92 20 14.72 1887 556 4.42 / 259.03 5 90
6 13 231.12 20 15.02 713 214 4.64 / 259.24 5 84
7 8 0.00 240 15.05 326 1178 5.82 / 260.42 5 135
Average= 5.31
(KJ/cycle)

Cycle 47 GMT 24/11/2021 21:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 33 15.04 491 244 0.24 / 249.06 5 39
2 7 2006.48 40 14.59 3286 1918 2.16 / 250.97 39 68
3 13 1922.12 20 14.57 3183 928 3.09 / 251.90 5 72
4 13 1493.16 20 14.61 2592 757 3.85 / 252.66 5 83
5 13 848.72 20 14.78 1649 487 4.33 / 253.15 5 92
6 13 377.44 20 14.95 950 284 4.62 / 253.43 5 93
7 8 0.16 233 15.04 334 1170 5.79 / 254.60 5 132
Average= 5.30
(KJ/cycle)

Cycle 46 GMT 15/11/2021 0:10: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 32 15.04 495 238 0.24 / 243.35 5 40
2 7 2008.00 40 14.59 3279 1914 2.15 / 245.26 40 67
3 13 1928.60 20 14.58 3189 930 3.08 / 246.19 5 71
4 13 1504.32 20 14.62 2609 763 3.84 / 246.96 5 83
5 13 734.40 20 14.84 1474 437 4.28 / 247.39 5 92
6 13 299.24 20 15.00 827 248 4.53 / 247.64 5 88
7 8 -0.04 236 15.05 330 1172 5.70 / 248.81 5 136
Average= 5.29
(KJ/cycle)

Cycle 45 GMT 5/11/2021 2:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 33 15.05 498 247 0.25 / 237.71 5 41
2 7 2005.76 40 14.59 3269 1908 2.16 / 239.61 41 66
3 13 1917.84 20 14.59 3172 926 3.08 / 240.54 5 71
4 13 1493.00 20 14.62 2587 756 3.84 / 241.30 5 82
5 13 830.12 20 14.81 1618 479 4.32 / 241.77 5 91
6 13 145.28 20 15.07 579 175 4.49 / 241.95 5 83
7 8 -0.08 231 15.06 334 1162 5.65 / 243.11 5 130
Average= 5.29
(KJ/cycle)

Cycle 44 GMT 26/10/2021 5:54: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 33 15.06 496 247 0.25 / 232.09 5 42
2 7 2003.36 40 14.60 3286 1919 2.17 / 234.01 42 67
3 13 1917.00 20 14.59 3181 928 3.09 / 234.93 5 72
4 13 1406.96 20 14.65 2476 725 3.82 / 235.66 5 84
5 13 740.48 20 14.84 1498 445 4.26 / 236.10 5 93
6 13 201.28 20 15.05 665 200 4.46 / 236.30 5 85
7 8 -0.04 233 15.06 329 1154 5.62 / 237.46 5 129
Average= 5.28
(KJ/cycle)

Cycle 43 GMT 16/10/2021 8:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 33 15.06 493 245 0.25 / 226.50 5 40
2 7 2005.92 40 14.59 3284 1917 2.16 / 228.42 40 67
3 13 1915.96 20 14.59 3189 931 3.09 / 229.35 5 72
4 13 1385.68 20 14.67 2423 711 3.80 / 230.06 5 83
5 13 745.16 20 14.85 1481 440 4.24 / 230.50 5 92
6 13 190.76 20 15.06 647 195 4.44 / 230.69 5 82
7 8 0.24 231 15.07 329 1145 5.58 / 231.84 5 135
Average= 5.27
(KJ/cycle)

Cycle 42 GMT 6/10/2021 11:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 33 15.06 504 250 0.25 / 220.85 5 40
2 7 2014.04 40 14.60 3292 1923 2.17 / 222.77 40 66
3 13 1922.40 20 14.60 3164 924 3.10 / 223.70 5 70
4 13 1402.08 20 14.66 2455 720 3.82 / 224.42 5 83
5 13 849.04 20 14.82 1647 488 4.30 / 224.90 5 91
6 13 183.68 20 15.07 640 193 4.50 / 225.10 5 80
7 8 0.08 234 15.07 329 1160 5.66 / 226.26 5 136
Average= 5.26
(KJ/cycle)

Cycle 41 GMT 26/ 9/2021 14:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 33 15.08 493 245 0.25 / 215.27 5 42
2 7 2008.12 40 14.60 3281 1916 2.16 / 217.19 42 66
3 13 1918.48 20 14.60 3179 928 3.09 / 218.11 5 71
4 13 1382.84 20 14.67 2435 714 3.80 / 218.83 5 82
5 13 942.08 20 14.78 1777 525 4.33 / 219.35 5 91
6 8 0.08 253 15.09 326 1245 5.57 / 220.60 5 136
Average= 5.25
(KJ/cycle)

Cycle 40 GMT 16/ 9/2021 16:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 33 15.09 483 241 0.24 / 209.79 5 40
2 7 2012.76 40 14.61 3285 1920 2.16 / 211.71 14 64
3 13 1915.96 20 14.61 3158 923 3.08 / 212.64 5 71
4 13 1369.48 20 14.68 2405 706 3.79 / 213.34 5 83
5 13 825.72 20 14.83 1599 474 4.26 / 213.82 5 90
6 8 0.04 251 15.10 319 1209 5.47 / 215.02 5 137
Average= 5.24
(KJ/cycle)

Cycle 39 GMT 6/ 9/2021 19:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 32 15.10 487 235 0.24 / 204.37 5 42
2 3 1018.48 1 15.16 1926 29 0.26 / 204.40 5 24
3 7 2006.64 40 14.61 3290 1923 2.19 / 206.32 24 65
4 13 1814.76 20 14.62 3041 889 3.08 / 207.21 5 72
5 13 1306.80 20 14.69 2317 681 3.76 / 207.89 5 82
6 13 779.44 20 14.85 1539 457 4.21 / 208.35 5 88
7 8 0.12 250 15.10 318 1200 5.41 / 209.55 5 133
Average= 5.24
(KJ/cycle)

Cycle 38 GMT 27/ 8/2021 22:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 32 15.10 482 233 0.23 / 198.88 5 42
2 7 2005.80 40 14.62 3280 1918 2.15 / 200.80 42 66
3 13 1811.52 20 14.64 3044 891 3.04 / 201.69 5 73
4 13 1491.00 20 14.66 2588 759 3.80 / 202.45 5 80
5 13 822.88 20 14.85 1604 476 4.28 / 202.93 5 89
6 8 0.20 253 15.12 316 1209 5.49 / 204.14 5 134
Average= 5.23
(KJ/cycle)

Cycle 37 GMT 18/ 8/2021 1:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 32 15.09 488 236 0.24 / 193.39 5 41
2 7 2005.32 40 14.63 3274 1916 2.15 / 195.31 7 66
3 13 1915.56 20 14.62 3168 926 3.08 / 196.23 5 71
4 13 1283.36 20 14.73 2270 669 3.75 / 196.90 5 84
5 13 860.36 20 14.84 1636 486 4.23 / 197.39 5 91
6 13 99.20 20 15.13 481 146 4.38 / 197.53 5 74
7 8 0.08 231 15.11 320 1117 5.49 / 198.65 5 132
Average= 5.23
(KJ/cycle)

Cycle 36 GMT 8/ 8/2021 4:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 32 15.10 484 234 0.23 / 187.74 5 42
2 7 2010.04 40 14.62 3278 1917 2.15 / 189.66 42 70
3 13 1915.12 20 14.62 3150 921 3.07 / 190.58 5 73
4 13 1470.32 20 14.67 2544 746 3.82 / 191.33 5 83
5 13 891.92 20 14.83 1689 501 4.32 / 191.83 5 92
6 13 410.68 20 15.00 977 293 4.61 / 192.12 5 91
7 8 0.00 216 15.10 317 1034 5.65 / 193.16 5 133
Average= 5.22
(KJ/cycle)

Cycle 35 GMT 29/ 7/2021 7:39: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 32 15.12 476 230 0.23 / 182.11 5 40
2 7 2003.68 40 14.62 3290 1924 2.15 / 184.04 40 66
3 13 1910.60 20 14.63 3168 927 3.08 / 184.96 5 71
4 13 1582.08 20 14.64 2696 789 3.87 / 185.75 5 79
5 13 795.12 20 14.87 1559 464 4.33 / 186.22 5 90
6 13 143.72 20 15.12 558 169 4.50 / 186.38 5 79
7 8 0.00 238 15.12 313 1126 5.63 / 187.51 5 137
Average= 5.21
(KJ/cycle)

Cycle 34 GMT 19/ 7/2021 10:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 32 15.12 485 235 0.23 / 176.63 5 41
2 7 2007.24 40 14.63 3277 1918 2.15 / 178.54 11 66
3 13 1912.72 20 14.63 3155 923 3.08 / 179.47 5 71
4 13 1365.28 20 14.72 2399 706 3.78 / 180.17 5 82
5 13 921.24 20 14.83 1742 517 4.30 / 180.69 5 90
6 13 134.68 20 15.13 540 163 4.46 / 180.85 5 77
7 8 0.20 220 15.13 309 1029 5.49 / 181.88 5 136
Average= 5.20
(KJ/cycle)

Cycle 33 GMT 9/ 7/2021 13:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 31 15.13 478 224 0.22 / 171.15 5 36
2 7 2003.52 40 14.64 3282 1922 2.15 / 173.07 14 67
3 13 1906.24 20 14.63 3148 921 3.07 / 174.00 5 72
4 13 1355.92 20 14.72 2389 703 3.77 / 174.70 5 83
5 13 813.76 20 14.87 1583 471 4.24 / 175.17 5 90
6 13 64.04 20 15.16 424 129 4.37 / 175.30 5 74
7 8 0.08 233 15.13 310 1093 5.46 / 176.39 5 142
Average= 5.19
(KJ/cycle)

Cycle 32 GMT 29/ 6/2021 16:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 31 15.14 481 226 0.23 / 165.71 5 33
2 7 2013.52 40 14.63 3294 1928 2.15 / 167.64 33 67
3 13 1822.08 20 14.66 3048 894 3.05 / 168.53 5 74
4 13 1405.32 20 14.71 2453 722 3.77 / 169.26 5 82
5 13 753.72 20 14.90 1491 444 4.21 / 169.70 5 91
6 13 99.68 20 15.15 483 146 4.36 / 169.85 5 76
7 8 0.00 232 15.14 308 1082 5.44 / 170.93 5 129
Average= 5.18
(KJ/cycle)

Cycle 31 GMT 19/ 6/2021 19:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 31 15.13 483 227 0.23 / 160.36 5 34
2 7 2011.20 40 14.64 3289 1926 2.15 / 162.28 9 67
3 13 1915.60 20 14.65 3149 923 3.08 / 163.20 5 73
4 13 1382.12 20 14.73 2400 707 3.78 / 163.91 5 81
5 13 640.84 20 14.94 1333 398 4.18 / 164.31 5 94
6 13 52.64 20 15.18 402 122 4.30 / 164.43 5 77
7 8 0.04 227 15.14 307 1055 5.36 / 165.49 5 129
Average= 5.17
(KJ/cycle)

Cycle 30 GMT 9/ 6/2021 21:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 31 15.14 477 224 0.22 / 154.88 5 32
2 7 2007.68 40 14.65 3276 1920 2.14 / 156.80 32 66
3 13 1912.80 20 14.64 3181 931 3.08 / 157.73 5 72
4 13 1399.04 20 14.74 2427 715 3.79 / 158.44 5 82
5 13 748.12 20 14.91 1485 443 4.23 / 158.89 5 92
6 13 101.16 20 15.16 490 149 4.38 / 159.03 5 80
7 8 -0.04 231 15.14 313 1095 5.48 / 160.13 5 131
Average= 5.17
(KJ/cycle)

Cycle 29 GMT 31/ 5/2021 0:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.80 31 15.14 487 229 0.23 / 149.47 5 33
2 7 2003.04 40 14.64 3281 1921 2.15 / 151.40 33 68
3 13 1905.56 20 14.66 3141 921 3.07 / 152.32 5 71
4 13 1360.48 20 14.75 2384 703 3.77 / 153.02 5 82
5 13 704.92 20 14.93 1432 428 4.20 / 153.45 5 92
6 13 84.60 20 15.17 466 141 4.34 / 153.59 5 81
7 8 0.04 225 15.15 312 1064 5.41 / 154.65 5 132
Average= 5.16
(KJ/cycle)

Cycle 28 GMT 21/ 5/2021 3:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.44 31 15.14 483 227 0.23 / 144.01 5 34
2 7 2011.28 40 14.65 3294 1930 2.16 / 145.94 34 68
3 13 1914.08 20 14.66 3159 926 3.08 / 146.86 5 72
4 13 1373.76 20 14.75 2396 707 3.79 / 147.57 5 82
5 13 715.84 20 14.93 1438 429 4.22 / 148.00 5 94
6 13 82.84 20 15.17 462 140 4.36 / 148.14 5 78
7 8 0.16 234 15.15 312 1106 5.47 / 149.25 5 132
Average= 5.15
(KJ/cycle)

Cycle 27 GMT 11/ 5/2021 6: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.48 31 15.15 465 218 0.22 / 138.41 5 31
2 7 2003.44 40 14.66 3281 1924 2.14 / 140.33 31 68
3 13 1908.24 20 14.66 3164 928 3.07 / 141.26 5 72
4 13 1364.76 20 14.75 2395 707 3.78 / 141.97 5 82
5 13 929.88 20 14.86 1769 526 4.30 / 142.49 5 90
6 13 237.52 20 15.11 721 218 4.52 / 142.71 5 88
7 8 0.12 225 15.15 314 1070 5.59 / 143.78 5 129
Average= 5.14
(KJ/cycle)

Cycle 26 GMT 1/ 5/2021 8:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 31 15.16 479 225 0.23 / 132.95 5 29
2 7 2006.64 40 14.66 3285 1926 2.15 / 134.87 29 68
3 13 1915.08 20 14.66 3162 927 3.08 / 135.80 5 72
4 13 1364.20 20 14.76 2390 706 3.78 / 136.51 5 83
5 13 704.64 20 14.95 1426 426 4.21 / 136.93 5 93
6 13 148.12 20 15.15 567 172 4.38 / 137.10 5 85
7 8 0.52 229 15.15 313 1086 5.47 / 138.19 5 143
Average= 5.12
(KJ/cycle)

Cycle 25 GMT 21/ 4/2021 11:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.96 31 15.16 468 220 0.22 / 127.41 5 31
2 7 2010.16 41 14.66 3286 1975 2.20 / 129.38 31 67
3 13 1812.40 20 14.69 3024 888 3.08 / 130.27 5 73
4 13 1279.60 20 14.79 2273 672 3.76 / 130.95 5 85
5 13 937.52 20 14.86 1762 524 4.28 / 131.47 5 90
6 13 115.92 20 15.17 515 156 4.44 / 131.63 5 85
7 8 0.08 234 15.16 309 1096 5.53 / 132.72 5 131
Average= 5.10
(KJ/cycle)

Cycle 24 GMT 11/ 4/2021 14:43: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 31 15.17 479 225 0.23 / 122.03 5 29
2 7 2007.56 40 14.68 3266 1918 2.14 / 123.95 9 69
3 13 1812.92 20 14.70 3037 893 3.04 / 124.84 5 72
4 13 1212.20 20 14.82 2164 641 3.68 / 125.49 5 85
5 13 785.40 20 14.92 1539 459 4.14 / 125.94 5 93
6 13 105.92 20 15.18 497 151 4.29 / 126.10 5 82
7 8 0.12 232 15.16 311 1094 5.38 / 127.19 5 131
Average= 5.09
(KJ/cycle)

Cycle 23 GMT 1/ 4/2021 17:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.52 31 15.17 479 225 0.23 / 116.55 5 32
2 7 2013.32 40 14.66 3308 1940 2.17 / 118.49 32 68
3 13 1920.16 20 14.68 3165 929 3.09 / 119.42 5 72
4 13 1372.84 20 14.76 2403 709 3.80 / 120.13 5 83
5 13 801.64 20 14.92 1577 471 4.27 / 120.60 5 93
6 13 72.52 20 15.20 447 136 4.41 / 120.74 5 80
7 8 0.08 225 15.17 313 1068 5.48 / 121.81 5 131
Average= 5.08
(KJ/cycle)

Cycle 22 GMT 22/ 3/2021 20: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 31 15.18 477 224 0.22 / 111.04 5 32
2 7 2015.32 40 14.67 3313 1944 2.17 / 112.98 32 67
3 13 1924.64 20 14.68 3183 935 3.10 / 113.92 5 71
4 13 1372.04 20 14.77 2403 710 3.81 / 114.63 5 83
5 13 822.44 20 14.92 1603 478 4.29 / 115.10 5 92
6 13 74.28 20 15.20 451 137 4.43 / 115.24 5 80
7 13 18.04 20 15.21 351 107 4.54 / 115.35 5 78
8 8 0.12 206 15.17 314 981 5.52 / 116.33 5 136
Average= 5.06
(KJ/cycle)

Cycle 21 GMT 12/ 3/2021 22:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.16 30 15.18 476 217 0.22 / 105.54 5 32
2 7 2004.56 40 14.68 3284 1928 2.15 / 107.46 32 68
3 13 1911.56 20 14.69 3165 930 3.08 / 108.39 5 72
4 13 1367.64 20 14.79 2398 709 3.78 / 109.10 5 85
5 13 818.20 20 14.92 1596 476 4.26 / 109.58 5 93
6 13 146.96 20 15.17 566 172 4.43 / 109.75 5 84
7 8 -0.04 225 15.18 311 1062 5.49 / 110.81 5 135
Average= 5.04
(KJ/cycle)

Cycle 20 GMT 3/ 3/2021 1:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 30 15.18 466 212 0.21 / 100.15 5 33
2 7 2007.96 40 14.67 3283 1926 2.14 / 102.07 33 69
3 13 1920.72 20 14.69 3167 930 3.07 / 103.01 5 72
4 13 1291.28 20 14.80 2302 681 3.75 / 103.69 5 87
5 13 666.24 20 14.98 1369 410 4.16 / 104.10 5 92
6 13 57.52 20 15.21 421 128 4.29 / 104.22 5 78
7 8 0.04 231 15.18 312 1094 5.38 / 105.32 5 130
Average= 5.02
(KJ/cycle)

Cycle 19 GMT 21/ 2/2021 4:16: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 30 15.18 478 218 0.22 / 94.72 5 32
2 7 2004.56 40 14.68 3287 1930 2.15 / 96.65 32 69
3 13 1911.84 20 14.69 3178 934 3.08 / 97.58 5 74
4 13 1364.88 20 14.78 2403 710 3.79 / 98.29 5 84
5 13 708.44 20 14.97 1434 429 4.22 / 98.72 5 95
6 13 69.24 20 15.21 435 132 4.35 / 98.85 5 78
7 8 0.00 229 15.18 311 1081 5.43 / 99.94 5 141
Average= 5.00
(KJ/cycle)

Cycle 18 GMT 11/ 2/2021 7: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 30 15.18 481 219 0.22 / 89.39 5 31
2 7 2002.84 40 14.69 3293 1935 2.15 / 91.32 31 70
3 13 1809.80 20 14.72 3036 894 3.05 / 92.22 5 75
4 13 1191.80 20 14.84 2145 637 3.68 / 92.85 5 87
5 13 758.48 20 14.95 1506 450 4.13 / 93.30 5 93
6 13 50.88 20 15.22 405 123 4.26 / 93.43 5 79
7 8 -0.04 229 15.19 309 1075 5.33 / 94.50 5 138
Average= 4.97
(KJ/cycle)

Cycle 17 GMT 1/ 2/2021 9:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 30 15.18 477 217 0.22 / 83.95 5 32
2 7 2005.96 40 14.69 3290 1933 2.15 / 85.88 32 71
3 13 1819.36 20 14.71 3035 893 3.04 / 86.77 5 75
4 13 1394.52 20 14.79 2438 721 3.76 / 87.49 5 84
5 13 723.16 20 14.97 1457 436 4.20 / 87.93 5 96
6 13 80.08 20 15.21 456 139 4.34 / 88.07 5 84
7 8 0.04 232 15.19 312 1100 5.44 / 89.17 5 135
Average= 4.95
(KJ/cycle)

Cycle 16 GMT 22/ 1/2021 12:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 30 15.19 484 221 0.22 / 78.45 5 32
2 7 2003.16 40 14.70 3284 1931 2.15 / 80.39 32 70
3 13 1913.04 20 14.71 3184 937 3.09 / 81.32 5 74
4 13 1474.20 20 14.77 2550 753 3.84 / 82.08 5 82
5 13 704.40 20 14.99 1427 428 4.27 / 82.50 5 94
6 13 68.88 20 15.22 441 134 4.40 / 82.64 5 82
7 8 -0.04 229 15.19 314 1092 5.50 / 83.73 5 134
Average= 4.93
(KJ/cycle)

Cycle 15 GMT 12/ 1/2021 15:23: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 31 15.19 489 230 0.23 / 73.03 5 35
2 7 2015.32 40 14.69 3304 1941 2.17 / 74.97 35 69
3 13 1921.24 20 14.71 3189 938 3.11 / 75.91 5 73
4 13 1346.76 20 14.81 2378 704 3.81 / 76.61 5 84
5 13 694.80 20 14.99 1423 427 4.24 / 77.04 5 94
6 13 33.40 20 15.24 382 116 4.36 / 77.15 5 81
7 8 0.04 225 15.20 316 1081 5.44 / 78.23 5 132
Average= 4.89
(KJ/cycle)

Cycle 14 GMT 2/ 1/2021 18: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 31 15.20 490 231 0.23 / 67.56 5 35
2 7 2010.12 40 14.70 3304 1943 2.17 / 69.51 35 69
3 13 1911.32 20 14.71 3164 931 3.10 / 70.44 5 74
4 13 1369.44 20 14.81 2411 714 3.82 / 71.15 5 85
5 13 718.36 20 14.99 1451 435 4.25 / 71.59 5 94
6 13 76.12 20 15.22 448 136 4.39 / 71.72 5 84
7 8 0.04 225 15.20 314 1074 5.46 / 72.80 5 131
Average= 4.85
(KJ/cycle)

Cycle 13 GMT 23/12/2020 20:46: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 31 15.20 485 229 0.23 / 62.13 5 38
2 7 2014.16 40 14.70 3313 1948 2.18 / 64.07 38 70
3 13 1917.84 20 14.72 3182 937 3.11 / 65.01 5 74
4 13 1261.72 20 14.84 2244 666 3.78 / 65.68 5 87
5 13 837.20 20 14.95 1620 484 4.26 / 66.16 5 91
6 13 74.16 20 15.23 446 136 4.40 / 66.30 5 81
7 8 0.16 218 15.21 312 1035 5.43 / 67.33 5 131
Average= 4.81
(KJ/cycle)

Cycle 12 GMT 13/12/2020 23:33: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 31 15.21 468 221 0.22 / 56.74 5 38
2 7 2005.92 40 14.71 3287 1934 2.15 / 58.67 38 70
3 13 1803.92 20 14.75 3038 896 3.05 / 59.57 5 77
4 13 1282.88 20 14.84 2284 678 3.73 / 60.25 5 86
5 13 745.64 20 14.98 1496 448 4.18 / 60.69 5 93
6 13 45.96 20 15.25 397 121 4.30 / 60.81 5 78
7 8 -0.08 229 15.21 311 1083 5.38 / 61.90 5 132
Average= 4.76
(KJ/cycle)

Cycle 11 GMT 4/12/2020 2:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 31 15.20 496 234 0.23 / 51.31 5 39
2 7 2003.20 40 14.72 3299 1942 2.18 / 53.25 39 71
3 13 1906.52 20 14.72 3176 935 3.11 / 54.19 5 73
4 13 1254.12 20 14.85 2254 669 3.78 / 54.85 5 87
5 13 723.68 20 15.00 1464 439 4.22 / 55.29 5 94
6 13 78.16 20 15.24 453 138 4.36 / 55.43 5 79
7 8 0.20 227 15.21 314 1084 5.44 / 56.52 5 130
Average= 4.71
(KJ/cycle)

Cycle 10 GMT 24/11/2020 5: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 31 15.21 483 228 0.23 / 45.99 5 38
2 7 2007.52 40 14.71 3302 1943 2.17 / 47.93 38 69
3 13 1913.40 20 14.73 3171 934 3.10 / 48.86 5 72
4 13 1165.96 20 14.88 2108 627 3.73 / 49.49 5 88
5 13 649.08 20 15.02 1343 403 4.14 / 49.89 5 94
6 13 50.60 20 15.25 402 123 4.26 / 50.02 5 78
7 8 0.00 225 15.22 309 1058 5.32 / 51.07 5 138
Average= 4.64
(KJ/cycle)

Cycle 9 GMT 14/11/2020 7:42:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 31 15.20 489 230 0.23 / 40.53 5 40
2 7 2008.72 40 14.73 3305 1947 2.18 / 42.47 40 71
3 13 1912.28 20 14.73 3200 943 3.12 / 43.42 5 74
4 13 1364.72 20 14.82 2415 716 3.84 / 44.13 5 86
5 13 699.76 20 15.01 1434 430 4.27 / 44.56 5 95
6 13 66.20 20 15.24 437 133 4.40 / 44.70 5 81
7 8 0.00 218 15.22 320 1062 5.46 / 45.76 5 129
Average= 4.58
(KJ/cycle)

Cycle 8 GMT 4/11/2020 10:30:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.32 30 15.22 495 226 0.23 / 34.87 5 42
2 3 1055.44 1 15.15 1972 30 0.26 / 34.90 5 65
3 7 2012.88 40 14.73 3312 1951 2.21 / 36.85 65 70
4 13 1927.16 20 14.73 3196 942 3.15 / 37.79 5 72
5 13 1486.92 20 14.80 2586 765 3.91 / 38.56 5 84
6 13 810.96 20 14.98 1583 474 4.39 / 39.03 5 93
7 13 132.80 20 15.23 540 164 4.55 / 39.20 5 81
8 8 0.04 229 15.22 315 1098 5.65 / 40.30 5 131
Average= 4.48
(KJ/cycle)

Cycle 7 GMT 25/10/2020 13:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.28 31 15.21 486 229 0.23 / 29.28 5 42
2 3 965.72 -1 15.55 0 0 0.00 / 29.28 5 42
3 7 2004.68 40 14.73 3302 1946 2.17 / 31.23 42 70
4 13 1909.36 20 14.76 3178 938 3.11 / 32.17 5 73
5 13 1586.40 20 14.77 2724 805 3.92 / 32.97 5 80
6 13 702.60 20 15.03 1418 426 4.34 / 33.40 5 94
7 13 149.36 20 15.23 569 173 4.52 / 33.57 5 83
8 8 0.08 225 15.23 313 1073 5.59 / 34.65 5 133
Average= 4.33
(KJ/cycle)

Cycle 6 GMT 15/10/2020 16:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.64 31 15.23 480 227 0.23 / 23.89 5 37
2 7 2004.24 40 14.73 3295 1941 2.17 / 25.83 37 70
3 13 1811.76 20 14.76 3034 896 3.06 / 26.72 5 77
4 13 1284.24 20 14.85 2282 678 3.74 / 27.40 5 87
5 13 832.60 20 14.96 1624 486 4.23 / 27.89 5 98
6 13 30.36 20 15.26 374 114 4.34 / 28.00 5 83
7 8 0.00 220 15.22 315 1055 5.40 / 29.06 5 134
Average= 4.15
(KJ/cycle)

Cycle 5 GMT 5/10/2020 18:59: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.44 31 15.25 462 218 0.22 / 18.45 5 41
2 7 2015.32 40 14.74 3310 1952 2.17 / 20.40 41 68
3 13 1924.44 20 14.74 3208 946 3.12 / 21.35 5 74
4 13 1373.32 20 14.84 2417 717 3.83 / 22.06 5 85
5 13 723.36 20 15.03 1442 433 4.27 / 22.50 5 91
6 13 19.08 20 15.28 347 106 4.37 / 22.60 5 70
7 8 0.16 227 15.24 305 1055 5.43 / 23.66 5 134
Average= 3.94
(KJ/cycle)

Cycle 4 GMT 25/ 9/2020 21:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 31 15.24 487 230 0.23 / 13.77 5 39
2 7 1510.00 41 14.95 2569 1575 1.80 / 15.35 39 69
3 13 1441.92 20 14.94 2515 751 2.56 / 16.10 5 74
4 13 1241.44 20 14.94 2212 661 3.22 / 16.76 5 81
5 13 481.88 20 15.17 1082 328 3.55 / 17.09 5 86
6 8 0.04 246 15.27 304 1142 4.69 / 18.23 5 136
Average= 3.65
(KJ/cycle)

Cycle 3 GMT 24/ 9/2020 11:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.68 31 15.23 488 230 0.23 / 9.09 5 45
2 7 1510.80 40 14.96 2561 1533 1.76 / 10.62 25 67
3 13 1440.24 20 14.95 2495 746 2.51 / 11.37 5 76
4 13 1344.56 20 14.92 2352 702 3.21 / 12.07 5 80
5 13 573.48 20 15.13 1214 367 3.58 / 12.44 5 86
6 8 0.04 240 15.27 302 1107 4.68 / 13.54 5 145
Average= 3.39
(KJ/cycle)

Cycle 2 GMT 23/ 9/2020 1:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 31 15.24 475 224 0.22 / 4.45 5 45
2 7 1515.68 40 14.95 2575 1540 1.76 / 5.99 45 72
3 13 1447.44 20 14.94 2504 748 2.51 / 6.74 5 75
4 13 1149.28 20 14.96 2065 618 3.13 / 7.35 5 80
5 13 610.60 20 15.11 1266 383 3.51 / 7.74 5 85
6 8 0.12 246 15.26 299 1122 4.64 / 8.86 5 133
Average= 2.95
(KJ/cycle)

Cycle 1 GMT 21/ 9/2020 15: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 31 15.40 477 228 0.23 / 1.78 5 37
2 7 982.92 40 15.08 1817 1096 1.32 / 2.88 37 80
3 13 324.16 20 15.26 825 252 1.58 / 3.13 5 76
4 8 0.16 240 15.29 298 1094 2.67 / 4.22 5 132
Average= 2.11
(KJ/cycle)

Cycle 0 GMT 21/ 9/2020 4:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.88 30 15.55 470 219 0.22 / 0.22 5 43
2 7 114.04 40 15.52 476 296 0.51 / 0.51 43 45
3 8 0.12 240 15.48 280 1040 1.56 / 1.56 5 135
Average= 1.56
(KJ/cycle)