Cycle 169 GMT 30/ 4/2024 23:38: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.88 38 14.82 479 270 0.27 / 982.00 5 42
2 7 2004.72 40 14.61 3255 1902 2.17 / 983.90 42 65
3 13 1923.08 20 14.57 3187 929 3.10 / 984.83 5 70
4 13 1611.20 20 14.53 2723 791 3.89 / 985.62 5 77
5 13 946.56 20 14.62 1734 507 4.40 / 986.12 5 86
6 13 311.60 20 14.81 788 233 4.63 / 986.36 5 87
7 8 -0.04 338 14.84 300 1505 6.14 / 987.86 5 129
Average= 14.53
(KJ/cycle)

Cycle 168 GMT 21/ 4/2024 2:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 38 14.84 501 283 0.28 / 975.90 5 39
2 7 2008.20 41 14.61 3273 1961 2.24 / 977.86 39 66
3 13 1921.28 20 14.56 3200 932 3.17 / 978.79 5 70
4 13 1505.60 20 14.54 2591 753 3.93 / 979.55 5 78
5 13 864.08 20 14.65 1602 469 4.40 / 980.01 5 84
6 13 421.96 20 14.77 951 281 4.68 / 980.30 5 87
7 8 -0.04 329 14.84 293 1431 6.11 / 981.73 5 138
Average= 14.65
(KJ/cycle)

Cycle 167 GMT 11/ 4/2024 5:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.08 37 14.83 497 273 0.27 / 969.83 5 42
2 7 2006.64 40 14.61 3277 1915 2.19 / 971.75 42 66
3 13 1908.16 20 14.57 3152 918 3.11 / 972.66 5 70
4 13 1694.72 20 14.53 2862 832 3.94 / 973.50 5 76
5 13 918.40 20 14.63 1694 496 4.43 / 973.99 5 87
6 13 163.20 20 14.87 553 164 4.60 / 974.16 5 79
7 8 0.08 330 14.85 298 1460 6.06 / 975.62 5 137
Average= 14.78
(KJ/cycle)

Cycle 166 GMT 1/ 4/2024 8:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 37 14.82 495 271 0.27 / 963.80 5 43
2 7 2007.20 40 14.61 3297 1927 2.20 / 965.72 5 66
3 13 1918.84 20 14.58 3181 928 3.13 / 966.65 5 70
4 13 1491.56 20 14.55 2560 745 3.87 / 967.40 5 79
5 13 953.28 20 14.62 1771 518 4.39 / 967.92 5 90
6 13 102.88 20 14.89 476 142 4.53 / 968.06 5 82
7 13 55.56 20 14.89 406 121 4.65 / 968.18 5 83
8 8 0.04 304 14.84 306 1380 6.03 / 969.56 5 138
Average= 14.92
(KJ/cycle)

Cycle 165 GMT 22/ 3/2024 11:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 37 14.83 488 268 0.27 / 957.67 5 40
2 7 2011.44 40 14.62 3294 1926 2.19 / 959.60 5 65
3 13 1931.48 20 14.56 3202 932 3.13 / 960.53 5 71
4 13 1495.24 20 14.54 2570 747 3.87 / 961.28 5 79
5 13 938.24 20 14.63 1713 501 4.38 / 961.78 5 85
6 13 288.48 20 14.82 735 218 4.59 / 962.00 5 83
7 8 -0.12 336 14.84 307 1531 6.12 / 963.53 5 134
Average= 15.06
(KJ/cycle)

Cycle 164 GMT 12/ 3/2024 14:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.96 37 14.82 492 270 0.27 / 951.43 5 42
2 7 2013.44 40 14.61 3300 1929 2.20 / 953.35 42 66
3 13 1926.12 20 14.57 3198 932 3.13 / 954.29 5 69
4 13 1721.56 20 14.52 2907 844 3.97 / 955.13 5 74
5 13 852.28 20 14.66 1598 469 4.44 / 955.60 5 87
6 13 527.68 20 14.73 1127 332 4.77 / 955.93 5 93
7 13 25.32 20 14.90 355 106 4.88 / 956.04 5 85
8 8 0.00 300 14.84 307 1367 6.25 / 957.40 5 134
Average= 15.20
(KJ/cycle)

Cycle 163 GMT 2/ 3/2024 18: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.72 37 14.82 476 261 0.26 / 945.10 5 41
2 7 2008.44 40 14.62 3295 1927 2.19 / 947.03 41 65
3 13 1923.52 20 14.58 3191 930 3.12 / 947.96 5 72
4 13 1592.84 20 14.54 2717 790 3.91 / 948.75 5 77
5 13 1131.00 20 14.57 2026 590 4.50 / 949.34 5 86
6 13 435.80 20 14.76 990 292 4.79 / 949.63 5 94
7 8 0.16 333 14.84 308 1522 6.31 / 951.16 5 135
Average= 15.34
(KJ/cycle)

Cycle 162 GMT 21/ 2/2024 21:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.00 38 14.81 490 276 0.28 / 939.05 5 41
2 7 2005.20 40 14.62 3290 1924 2.20 / 940.98 41 67
3 13 1918.56 20 14.57 3179 926 3.13 / 941.90 5 70
4 13 1417.92 20 14.56 2466 718 3.84 / 942.62 5 81
5 13 1097.88 20 14.58 1979 577 4.42 / 943.20 5 85
6 13 177.88 20 14.85 590 175 4.60 / 943.37 5 90
7 8 -0.04 321 14.84 308 1467 6.06 / 944.84 5 133
Average= 15.49
(KJ/cycle)

Cycle 161 GMT 12/ 2/2024 0:21: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 38 14.84 483 272 0.27 / 932.81 5 42
2 7 2013.28 40 14.61 3300 1929 2.20 / 934.74 42 66
3 13 1916.84 20 14.58 3181 928 3.13 / 935.66 5 69
4 13 1721.56 20 14.52 2905 844 3.97 / 936.51 5 76
5 13 917.48 20 14.64 1718 503 4.48 / 937.01 5 90
6 13 484.64 20 14.74 1068 315 4.79 / 937.33 5 96
7 8 -0.16 317 14.83 309 1453 6.24 / 938.78 5 129
Average= 15.65
(KJ/cycle)

Cycle 160 GMT 2/ 2/2024 3:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.60 37 14.82 492 270 0.27 / 927.02 5 44
2 7 2012.12 40 14.61 3315 1937 2.21 / 928.95 44 64
3 13 1922.88 20 14.58 3181 928 3.13 / 929.88 5 71
4 13 1418.08 20 14.56 2458 716 3.85 / 930.60 5 80
5 13 892.12 20 14.64 1669 489 4.34 / 931.09 5 91
6 13 134.92 20 14.87 525 156 4.50 / 931.24 5 87
7 8 0.12 282 14.85 309 1294 5.79 / 932.54 5 133
Average= 15.81
(KJ/cycle)

Cycle 159 GMT 23/ 1/2024 6: 8: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 37 14.83 503 276 0.28 / 921.08 5 43
2 7 2005.64 40 14.62 3300 1930 2.21 / 923.01 43 67
3 13 1922.28 20 14.57 3215 937 3.14 / 923.94 5 71
4 13 1494.92 20 14.56 2590 754 3.90 / 924.70 5 80
5 13 887.52 20 14.64 1672 490 4.39 / 925.19 5 90
6 13 159.24 20 14.86 577 171 4.56 / 925.36 5 91
7 8 0.20 293 14.85 319 1388 5.95 / 926.75 5 140
Average= 15.98
(KJ/cycle)

Cycle 158 GMT 13/ 1/2024 8:59: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 37 14.83 493 271 0.27 / 915.10 5 44
2 7 2006.76 41 14.61 3293 1973 2.24 / 917.07 44 67
3 13 1909.80 20 14.58 3174 926 3.17 / 918.00 5 71
4 13 1372.08 20 14.57 2403 700 3.87 / 918.70 5 81
5 13 947.96 20 14.62 1768 517 4.39 / 919.21 5 89
6 13 279.72 20 14.81 754 223 4.61 / 919.44 5 90
7 8 -0.04 291 14.84 316 1365 5.97 / 920.80 5 131
Average= 16.15
(KJ/cycle)

Cycle 157 GMT 3/ 1/2024 12: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.60 37 14.82 491 269 0.27 / 909.13 5 43
2 7 2016.08 40 14.62 3315 1939 2.21 / 911.07 43 69
3 13 1925.72 20 14.57 3208 935 3.14 / 912.00 5 70
4 13 1402.80 20 14.57 2444 712 3.85 / 912.71 5 82
5 13 879.60 20 14.64 1669 489 4.34 / 913.20 5 90
6 13 233.28 20 14.83 700 208 4.55 / 913.41 5 95
7 8 -0.04 295 14.84 324 1418 5.97 / 914.83 5 137
Average= 16.34
(KJ/cycle)

Cycle 156 GMT 24/12/2023 14:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 37 14.82 505 277 0.28 / 903.05 5 46
2 7 2004.32 40 14.63 3288 1924 2.20 / 904.97 46 65
3 13 1905.36 20 14.59 3178 927 3.13 / 905.90 5 71
4 13 1494.72 20 14.56 2584 752 3.88 / 906.65 5 80
5 13 984.72 20 14.61 1832 535 4.42 / 907.19 5 90
6 13 318.16 20 14.80 818 242 4.66 / 907.43 5 92
7 8 0.12 291 14.83 331 1428 6.09 / 908.86 5 131
Average= 16.52
(KJ/cycle)

Cycle 155 GMT 14/12/2023 18: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.36 37 14.82 507 278 0.28 / 896.82 5 49
2 7 2014.24 40 14.62 3310 1936 2.21 / 898.76 49 67
3 13 1924.60 20 14.58 3202 934 3.15 / 899.69 5 70
4 13 1603.80 20 14.54 2754 801 3.95 / 900.49 5 78
5 13 940.96 20 14.63 1768 517 4.47 / 901.01 5 89
6 13 494.32 20 14.74 1093 322 4.79 / 901.33 5 94
7 8 -0.08 296 14.83 328 1440 6.23 / 902.77 5 132
Average= 16.72
(KJ/cycle)

Cycle 154 GMT 4/12/2023 21:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 37 14.82 495 271 0.27 / 890.84 5 49
2 7 2005.92 40 14.62 3291 1925 2.20 / 892.76 49 68
3 13 1916.08 20 14.58 3195 932 3.13 / 893.70 5 71
4 13 1390.56 20 14.57 2431 708 3.84 / 894.40 5 81
5 13 956.60 20 14.62 1796 525 4.36 / 894.93 5 90
6 13 191.36 20 14.85 626 186 4.55 / 895.11 5 92
7 8 0.24 298 14.84 323 1428 5.98 / 896.54 5 132
Average= 16.92
(KJ/cycle)

Cycle 153 GMT 25/11/2023 0: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 37 14.82 506 277 0.28 / 884.75 5 51
2 7 2014.84 40 14.62 3316 1939 2.22 / 886.69 51 66
3 13 1929.68 20 14.58 3209 936 3.15 / 887.62 5 72
4 13 1506.32 20 14.55 2609 759 3.91 / 888.38 5 81
5 13 959.68 20 14.61 1811 529 4.44 / 888.91 5 90
6 13 301.04 20 14.81 795 235 4.68 / 889.15 5 91
7 8 -0.12 293 14.84 327 1422 6.10 / 890.57 5 131
Average= 17.13
(KJ/cycle)

Cycle 152 GMT 15/11/2023 3: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.60 37 14.82 483 265 0.26 / 878.66 5 49
2 7 2006.48 40 14.62 3276 1916 2.18 / 880.58 49 67
3 13 1917.96 20 14.58 3188 930 3.11 / 881.51 5 69
4 13 1607.64 20 14.54 2760 803 3.91 / 882.31 5 79
5 13 930.76 20 14.63 1748 511 4.42 / 882.82 5 91
6 13 287.48 20 14.81 773 229 4.65 / 883.05 5 95
7 8 0.00 289 14.84 331 1420 6.07 / 884.47 5 140
Average= 17.34
(KJ/cycle)

Cycle 151 GMT 5/11/2023 6:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.80 37 14.83 503 276 0.28 / 872.76 5 48
2 7 2008.80 40 14.63 3279 1919 2.19 / 874.68 48 66
3 13 1926.68 20 14.59 3222 940 3.14 / 875.62 5 71
4 13 1419.96 20 14.57 2482 723 3.86 / 876.34 5 81
5 13 888.44 20 14.64 1687 494 4.35 / 876.84 5 92
6 13 244.28 20 14.83 712 211 4.56 / 877.05 5 96
7 8 0.00 278 14.84 327 1349 5.91 / 878.40 5 136
Average= 17.57
(KJ/cycle)

Cycle 150 GMT 26/10/2023 9: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 37 14.82 500 274 0.27 / 866.68 5 51
2 7 2009.84 40 14.62 3293 1926 2.20 / 868.60 51 68
3 13 1925.00 20 14.59 3213 938 3.14 / 869.54 5 72
4 13 1507.60 20 14.55 2605 758 3.90 / 870.30 5 78
5 13 978.28 20 14.61 1820 532 4.43 / 870.83 5 89
6 13 336.92 20 14.79 848 251 4.68 / 871.08 5 94
7 8 0.00 287 14.83 330 1405 6.08 / 872.48 5 130
Average= 17.81
(KJ/cycle)

Cycle 149 GMT 16/10/2023 12: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 37 14.83 508 279 0.28 / 860.62 5 49
2 7 2005.40 40 14.63 3296 1929 2.21 / 862.55 49 67
3 13 1913.48 20 14.59 3185 929 3.14 / 863.48 5 72
4 13 1600.08 20 14.55 2743 798 3.94 / 864.28 5 78
5 13 863.16 20 14.65 1655 485 4.42 / 864.76 5 91
6 13 321.68 20 14.80 827 245 4.66 / 865.01 5 92
7 8 -0.04 287 14.84 327 1393 6.06 / 866.40 5 131
Average= 18.05
(KJ/cycle)

Cycle 148 GMT 6/10/2023 15: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 37 14.83 498 273 0.27 / 854.69 5 49
2 7 2004.48 40 14.62 3298 1929 2.20 / 856.62 49 67
3 13 1912.40 20 14.59 3198 933 3.14 / 857.55 5 71
4 13 1401.00 20 14.57 2454 715 3.85 / 858.27 5 82
5 13 962.28 20 14.61 1823 533 4.38 / 858.80 5 90
6 13 300.08 20 14.80 803 238 4.62 / 859.04 5 92
7 8 0.48 267 14.84 329 1304 5.92 / 860.34 5 134
Average= 18.31
(KJ/cycle)

Cycle 147 GMT 26/ 9/2023 18:14: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.32 37 14.84 499 274 0.27 / 848.73 5 51
2 7 2006.32 40 14.63 3283 1921 2.20 / 850.65 51 67
3 13 1908.60 20 14.58 3191 930 3.13 / 851.58 5 71
4 13 1486.48 20 14.57 2577 751 3.88 / 852.33 5 81
5 13 1046.52 20 14.60 1927 563 4.44 / 852.89 5 88
6 13 160.52 20 14.86 582 173 4.61 / 853.07 5 92
7 8 -0.16 278 14.84 328 1353 5.97 / 854.42 5 130
Average= 18.57
(KJ/cycle)

Cycle 146 GMT 16/ 9/2023 21:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 37 14.84 482 265 0.26 / 842.61 5 49
2 7 2009.16 40 14.62 3317 1940 2.20 / 844.55 49 65
3 13 1916.04 20 14.59 3183 929 3.13 / 845.48 5 69
4 13 1701.64 20 14.54 2891 841 3.97 / 846.32 5 76
5 13 950.00 20 14.63 1781 521 4.50 / 846.84 5 88
6 13 401.16 20 14.77 952 281 4.78 / 847.12 5 94
7 8 0.12 270 14.84 332 1330 6.11 / 848.45 5 133
Average= 18.85
(KJ/cycle)

Cycle 145 GMT 7/ 9/2023 0:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 37 14.84 499 274 0.27 / 836.66 5 47
2 7 2007.56 40 14.63 3290 1925 2.20 / 838.58 47 66
3 13 1919.48 20 14.59 3198 933 3.13 / 839.52 5 70
4 13 1485.96 20 14.57 2596 756 3.89 / 840.27 5 80
5 13 1054.00 20 14.59 1931 563 4.45 / 840.84 5 87
6 13 171.92 20 14.86 592 176 4.63 / 841.01 5 89
7 8 -0.04 279 14.85 322 1334 5.96 / 842.35 5 142
Average= 19.14
(KJ/cycle)

Cycle 144 GMT 28/ 8/2023 3:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 37 14.82 499 274 0.27 / 830.77 5 47
2 7 2016.56 40 14.62 3311 1936 2.21 / 832.71 47 68
3 13 1932.88 20 14.58 3232 942 3.15 / 833.65 5 69
4 13 1496.64 20 14.56 2604 758 3.91 / 834.41 5 81
5 13 960.72 20 14.62 1793 524 4.43 / 834.93 5 90
6 13 96.32 20 14.89 480 143 4.58 / 835.07 5 88
7 8 0.16 270 14.85 327 1311 5.89 / 836.39 5 131
Average= 19.45
(KJ/cycle)

Cycle 143 GMT 18/ 8/2023 6:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.28 37 14.83 491 269 0.27 / 824.70 5 50
2 7 2016.04 40 14.62 3309 1935 2.20 / 826.63 50 66
3 13 1933.36 20 14.57 3229 941 3.15 / 827.58 5 71
4 13 1516.00 20 14.55 2642 769 3.91 / 828.34 5 78
5 13 985.56 20 14.61 1840 538 4.45 / 828.88 5 90
6 13 332.76 20 14.80 846 250 4.70 / 829.13 5 93
7 8 0.08 276 14.84 333 1364 6.07 / 830.50 5 136
Average= 19.77
(KJ/cycle)

Cycle 142 GMT 8/ 8/2023 9:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.76 37 14.83 503 276 0.28 / 818.96 5 45
2 7 2006.88 40 14.63 3280 1919 2.20 / 820.88 45 68
3 13 1920.32 20 14.58 3204 934 3.13 / 821.81 5 68
4 13 1512.92 20 14.56 2613 761 3.89 / 822.57 5 79
5 13 760.36 20 14.68 1495 439 4.33 / 823.01 5 92
6 13 134.40 20 14.87 547 163 4.49 / 823.17 5 88
7 8 -0.28 255 14.85 332 1257 5.75 / 824.43 5 133
Average= 20.11
(KJ/cycle)

Cycle 141 GMT 29/ 7/2023 12:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 37 14.83 495 272 0.27 / 813.09 5 43
2 7 2015.76 40 14.62 3312 1937 2.21 / 815.02 43 67
3 13 1931.04 20 14.59 3213 938 3.15 / 815.96 5 70
4 13 1314.40 20 14.59 2337 682 3.83 / 816.64 5 84
5 13 1000.20 20 14.61 1861 544 4.37 / 817.19 5 90
6 13 114.92 20 14.87 511 152 4.52 / 817.34 5 86
7 8 0.04 274 14.84 330 1342 5.87 / 818.68 5 132
Average= 20.47
(KJ/cycle)

Cycle 140 GMT 19/ 7/2023 15:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.36 37 14.84 501 275 0.28 / 807.06 5 43
2 7 2006.40 40 14.62 3300 1930 2.20 / 808.99 43 66
3 13 1916.56 20 14.59 3193 932 3.14 / 809.92 5 71
4 13 1588.88 20 14.55 2728 794 3.93 / 810.71 5 78
5 13 926.84 20 14.64 1750 512 4.44 / 811.23 5 88
6 13 365.36 20 14.79 900 266 4.71 / 811.49 5 93
7 8 0.04 270 14.84 330 1322 6.03 / 812.81 5 129
Average= 20.84
(KJ/cycle)

Cycle 139 GMT 9/ 7/2023 18:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 37 14.84 501 275 0.28 / 801.21 5 41
2 7 2004.40 40 14.64 3286 1924 2.20 / 803.13 7 68
3 13 1926.00 20 14.60 3214 938 3.14 / 804.07 5 68
4 13 1487.04 20 14.57 2583 753 3.89 / 804.82 5 79
5 13 941.60 20 14.63 1764 516 4.41 / 805.34 5 88
6 13 100.16 20 14.89 488 145 4.55 / 805.48 5 87
7 8 0.08 265 14.85 330 1299 5.85 / 806.78 5 131
Average= 21.23
(KJ/cycle)

Cycle 138 GMT 29/ 6/2023 21:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.24 37 14.84 491 270 0.27 / 795.20 5 39
2 7 2007.36 40 14.63 3314 1939 2.21 / 797.14 39 65
3 13 1925.92 20 14.60 3202 935 3.14 / 798.08 5 69
4 13 1514.60 20 14.56 2628 765 3.91 / 798.84 5 80
5 13 884.08 20 14.65 1684 493 4.40 / 799.34 5 90
6 13 357.36 20 14.80 883 261 4.66 / 799.60 5 91
7 8 0.00 274 14.84 328 1334 6.00 / 800.93 5 141
Average= 21.65
(KJ/cycle)

Cycle 137 GMT 20/ 6/2023 0:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 37 14.84 491 270 0.27 / 789.38 5 38
2 7 2012.16 40 14.63 3305 1934 2.20 / 791.31 38 67
3 13 1930.08 20 14.59 3229 942 3.15 / 792.25 5 71
4 13 1512.96 20 14.56 2616 762 3.91 / 793.02 5 80
5 13 766.92 20 14.68 1508 443 4.35 / 793.46 5 92
6 13 242.00 20 14.84 712 211 4.56 / 793.67 5 93
7 13 24.04 20 14.90 369 110 4.67 / 793.78 5 89
8 8 0.00 238 14.85 327 1156 5.83 / 794.94 5 134
Average= 22.08
(KJ/cycle)

Cycle 136 GMT 10/ 6/2023 3: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.00 37 14.85 493 271 0.27 / 783.48 5 41
2 7 2010.96 40 14.63 3310 1937 2.21 / 785.42 41 67
3 13 1921.32 20 14.59 3207 936 3.14 / 786.36 5 69
4 13 1505.92 20 14.57 2608 760 3.90 / 787.12 5 80
5 13 861.04 20 14.65 1646 482 4.39 / 787.60 5 91
6 13 219.64 20 14.84 674 200 4.59 / 787.80 5 91
7 8 0.16 272 14.85 324 1309 5.89 / 789.11 5 140
Average= 22.55
(KJ/cycle)

Cycle 135 GMT 31/ 5/2023 6:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.48 37 14.84 490 269 0.27 / 777.65 5 40
2 7 2013.12 40 14.63 3307 1935 2.20 / 779.59 40 65
3 13 1934.72 20 14.59 3214 938 3.14 / 780.52 5 69
4 13 1614.48 20 14.55 2771 806 3.95 / 781.33 5 77
5 13 870.76 20 14.66 1670 490 4.44 / 781.82 5 92
6 13 119.52 20 14.89 516 154 4.59 / 781.97 5 87
7 8 0.16 255 14.86 327 1239 5.83 / 783.21 5 129
Average= 23.04
(KJ/cycle)

Cycle 134 GMT 21/ 5/2023 9: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 37 14.84 501 275 0.28 / 771.68 5 40
2 7 2007.36 41 14.63 3311 1986 2.26 / 773.67 40 67
3 13 1921.76 20 14.59 3211 937 3.20 / 774.61 5 70
4 13 1419.56 20 14.58 2487 725 3.92 / 775.33 5 83
5 13 987.56 20 14.62 1847 540 4.46 / 775.87 5 89
6 13 310.92 20 14.81 816 242 4.71 / 776.11 5 91
7 8 0.08 261 14.85 327 1267 5.97 / 777.38 5 132
Average= 23.56
(KJ/cycle)

Cycle 133 GMT 11/ 5/2023 12:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 37 14.83 522 286 0.29 / 765.67 6 40
2 7 2012.96 40 14.64 3325 1947 2.23 / 767.62 8 66
3 13 1929.88 20 14.59 3228 942 3.18 / 768.56 5 71
4 13 1420.08 20 14.58 2500 729 3.90 / 769.29 5 80
5 13 1003.84 20 14.61 1870 546 4.45 / 769.84 5 87
6 13 335.16 20 14.80 851 252 4.70 / 770.09 5 89
7 8 -0.20 270 14.84 330 1322 6.03 / 771.41 5 134
Average= 24.11
(KJ/cycle)

Cycle 132 GMT 1/ 5/2023 15: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 37 14.85 501 275 0.28 / 759.55 6 35
2 7 2009.92 40 14.64 3321 1945 2.22 / 761.49 35 68
3 13 1916.56 20 14.60 3206 936 3.16 / 762.43 5 70
4 13 1492.96 20 14.57 2607 760 3.92 / 763.19 5 81
5 13 1053.48 20 14.60 1945 568 4.48 / 763.76 5 90
6 13 384.12 20 14.79 928 275 4.76 / 764.03 5 93
7 8 0.24 274 14.85 333 1355 6.11 / 765.38 5 131
Average= 24.69
(KJ/cycle)

Cycle 131 GMT 21/ 4/2023 18:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 37 14.84 509 279 0.28 / 753.63 6 34
2 7 2007.80 40 14.64 3292 1928 2.21 / 755.55 34 65
3 13 1916.24 20 14.60 3190 931 3.14 / 756.49 5 71
4 13 1490.80 20 14.58 2591 756 3.89 / 757.24 5 80
5 13 857.52 20 14.66 1660 487 4.38 / 757.73 5 90
6 13 321.68 20 14.81 841 249 4.63 / 757.98 5 89
7 8 0.00 261 14.85 334 1295 5.92 / 759.27 5 129
Average= 25.31
(KJ/cycle)

Cycle 130 GMT 11/ 4/2023 21:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.32 37 14.85 493 271 0.27 / 747.63 6 34
2 7 2017.44 40 14.63 3321 1943 2.21 / 749.57 6 64
3 13 1936.16 20 14.59 3232 943 3.16 / 750.52 5 71
4 13 1509.52 20 14.56 2628 765 3.92 / 751.28 5 80
5 13 956.12 20 14.63 1796 526 4.45 / 751.81 5 88
6 13 190.96 20 14.85 642 191 4.64 / 752.00 5 90
7 8 0.16 273 14.85 333 1350 5.99 / 753.35 5 139
Average= 25.98
(KJ/cycle)

Cycle 129 GMT 2/ 4/2023 0:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 37 14.87 500 275 0.28 / 741.65 6 29
2 7 2011.00 40 14.64 3316 1942 2.22 / 743.59 29 65
3 13 1931.96 20 14.60 3231 943 3.16 / 744.54 5 71
4 13 1515.44 20 14.57 2625 765 3.93 / 745.30 5 78
5 13 971.48 20 14.63 1815 531 4.46 / 745.83 5 89
6 13 322.48 20 14.81 834 247 4.70 / 746.08 5 91
7 8 0.04 264 14.86 326 1279 5.98 / 747.36 5 136
Average= 26.69
(KJ/cycle)

Cycle 128 GMT 23/ 3/2023 3:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 37 14.85 493 271 0.27 / 735.74 6 29
2 7 2005.96 40 14.64 3302 1934 2.20 / 737.68 29 67
3 13 1914.96 20 14.60 3189 931 3.14 / 738.61 5 72
4 13 1496.64 20 14.57 2599 757 3.89 / 739.36 5 82
5 13 1048.32 20 14.61 1930 564 4.46 / 739.93 5 89
6 13 155.24 20 14.88 568 169 4.63 / 740.10 5 88
7 8 -0.04 264 14.86 326 1279 5.90 / 741.38 5 146
Average= 27.46
(KJ/cycle)

Cycle 127 GMT 13/ 3/2023 6:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.00 37 14.86 478 263 0.26 / 729.83 6 30
2 7 2015.08 40 14.64 3334 1952 2.22 / 731.78 30 68
3 13 1932.00 20 14.60 3246 948 3.16 / 732.73 5 70
4 13 1320.20 20 14.60 2346 685 3.85 / 733.41 5 82
5 13 908.80 20 14.65 1732 507 4.36 / 733.92 5 91
6 13 340.24 20 14.81 857 254 4.61 / 734.18 5 92
7 8 0.04 270 14.85 323 1295 5.90 / 735.47 5 132
Average= 28.29
(KJ/cycle)

Cycle 126 GMT 3/ 3/2023 9:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.80 37 14.85 502 276 0.28 / 723.96 6 31
2 7 2015.92 40 14.63 3331 1949 2.23 / 725.91 31 67
3 13 1926.84 20 14.60 3216 939 3.16 / 726.85 5 71
4 13 1503.44 20 14.57 2616 762 3.93 / 727.61 5 79
5 13 870.00 20 14.67 1671 490 4.42 / 728.10 5 91
6 13 214.96 20 14.85 683 203 4.62 / 728.31 5 93
7 13 19.68 20 14.91 368 110 4.73 / 728.42 5 93
8 8 -0.04 233 14.86 332 1150 5.88 / 729.57 5 129
Average= 29.18
(KJ/cycle)

Cycle 125 GMT 21/ 2/2023 12:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 37 14.85 508 279 0.28 / 717.93 6 34
2 7 2016.64 40 14.64 3326 1948 2.23 / 719.87 34 65
3 13 1929.92 20 14.60 3221 941 3.17 / 720.81 5 70
4 13 1609.16 20 14.56 2764 805 3.97 / 721.62 5 77
5 13 849.84 20 14.68 1639 481 4.45 / 722.10 5 92
6 13 314.24 20 14.82 819 243 4.70 / 722.34 5 93
7 8 -0.08 274 14.86 330 1344 6.04 / 723.69 5 139
Average= 30.15
(KJ/cycle)

Cycle 124 GMT 11/ 2/2023 15:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.88 37 14.85 507 279 0.28 / 711.91 6 31
2 7 2009.60 40 14.65 3296 1931 2.21 / 713.84 31 68
3 13 1917.92 20 14.61 3206 937 3.15 / 714.78 5 70
4 13 1500.72 20 14.59 2623 765 3.91 / 715.54 5 79
5 13 961.12 20 14.65 1805 529 4.44 / 716.07 5 87
6 13 295.28 20 14.83 796 236 4.68 / 716.31 5 92
7 8 0.28 270 14.86 334 1340 6.02 / 717.65 5 129
Average= 31.20
(KJ/cycle)

Cycle 123 GMT 1/ 2/2023 18:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.20 37 14.86 508 279 0.28 / 705.87 6 35
2 7 2007.08 41 14.64 3304 1983 2.26 / 707.86 35 64
3 13 1926.04 20 14.60 3219 940 3.20 / 708.80 5 70
4 13 1506.72 20 14.58 2611 761 3.96 / 709.56 5 80
5 13 857.20 20 14.67 1650 484 4.45 / 710.04 5 92
6 13 203.24 20 14.86 653 194 4.64 / 710.24 5 93
7 8 -0.28 285 14.86 329 1393 6.04 / 711.63 5 139
Average= 32.35
(KJ/cycle)

Cycle 122 GMT 22/ 1/2023 21:20: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 37 14.84 506 278 0.28 / 699.91 5 39
2 7 2007.00 41 14.65 3288 1975 2.25 / 701.88 39 67
3 13 1917.28 20 14.61 3208 937 3.19 / 702.82 5 72
4 13 1482.44 20 14.59 2575 751 3.94 / 703.57 5 81
5 13 929.60 20 14.66 1758 515 4.46 / 704.09 5 89
6 13 156.12 20 14.88 580 173 4.63 / 704.26 5 93
7 8 0.04 272 14.87 330 1335 5.96 / 705.59 5 134
Average= 33.60
(KJ/cycle)

Cycle 121 GMT 13/ 1/2023 0:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 37 14.84 515 283 0.28 / 693.84 5 42
2 7 2015.28 41 14.64 3328 1998 2.28 / 695.84 42 66
3 13 1926.32 20 14.60 3231 943 3.22 / 696.79 5 71
4 13 1407.80 20 14.60 2480 724 3.95 / 697.51 5 83
5 13 878.80 20 14.67 1680 493 4.44 / 698.00 5 93
6 13 212.44 20 14.86 672 200 4.64 / 698.20 5 97
7 8 -0.20 287 14.85 335 1428 6.07 / 699.63 5 129
Average= 34.98
(KJ/cycle)

Cycle 120 GMT 3/ 1/2023 3:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 37 14.84 510 280 0.28 / 687.85 5 42
2 7 2013.72 40 14.65 3307 1938 2.22 / 689.78 42 67
3 13 1931.00 20 14.61 3220 941 3.16 / 690.72 5 69
4 13 1393.16 20 14.61 2442 714 3.87 / 691.44 5 85
5 13 978.20 20 14.65 1824 534 4.41 / 691.97 5 90
6 13 213.16 20 14.86 672 200 4.61 / 692.17 5 96
7 8 -0.12 280 14.86 334 1390 6.00 / 693.56 5 136
Average= 36.50
(KJ/cycle)

Cycle 119 GMT 24/12/2022 6:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 37 14.86 512 282 0.28 / 681.76 5 41
2 7 2007.00 40 14.64 3316 1942 2.22 / 683.70 41 67
3 13 1920.76 20 14.60 3219 940 3.16 / 684.64 5 71
4 13 1394.48 20 14.60 2455 717 3.88 / 685.36 5 82
5 13 963.24 20 14.65 1813 531 4.41 / 685.89 5 89
6 13 399.36 20 14.79 946 280 4.69 / 686.17 5 92
7 8 0.20 276 14.85 340 1394 6.08 / 687.57 5 129
Average= 38.20
(KJ/cycle)

Cycle 118 GMT 14/12/2022 9:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 37 14.85 507 279 0.28 / 675.73 5 42
2 7 2007.80 40 14.65 3327 1950 2.23 / 677.68 42 68
3 13 1922.44 20 14.61 3236 946 3.17 / 678.63 5 72
4 13 1504.92 20 14.59 2614 763 3.94 / 679.39 5 79
5 13 858.24 20 14.68 1652 485 4.42 / 679.87 5 92
6 13 425.68 20 14.79 991 293 4.71 / 680.17 5 95
7 8 -0.08 263 14.86 336 1313 6.03 / 681.48 5 133
Average= 40.09
(KJ/cycle)

Cycle 117 GMT 4/12/2022 12:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 37 14.86 503 277 0.28 / 669.74 5 43
2 7 2013.12 41 14.64 3316 1990 2.27 / 671.73 43 65
3 13 1922.80 20 14.62 3220 942 3.21 / 672.67 5 70
4 13 1393.36 20 14.60 2459 718 3.93 / 673.39 5 82
5 13 863.24 20 14.68 1668 490 4.42 / 673.88 5 91
6 13 206.96 20 14.87 661 197 4.61 / 674.08 5 92
7 8 0.04 275 14.87 336 1374 5.99 / 675.45 5 131
Average= 42.22
(KJ/cycle)

Cycle 116 GMT 24/11/2022 15:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.84 37 14.85 510 280 0.28 / 663.78 5 47
2 7 2005.68 41 14.65 3304 1985 2.26 / 665.77 47 67
3 13 1910.16 20 14.61 3193 933 3.20 / 666.70 5 71
4 13 1585.80 20 14.58 2742 800 4.00 / 667.50 5 79
5 13 830.44 20 14.69 1611 473 4.47 / 667.97 5 93
6 13 90.88 20 14.92 475 142 4.61 / 668.11 5 85
7 8 -0.04 272 14.88 334 1352 5.96 / 669.47 5 133
Average= 44.63
(KJ/cycle)

Cycle 115 GMT 14/11/2022 18:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 37 14.84 521 286 0.29 / 657.85 5 53
2 7 2004.44 40 14.66 3313 1943 2.23 / 659.79 53 68
3 13 1921.12 20 14.62 3216 940 3.17 / 660.73 5 72
4 13 1403.72 20 14.60 2482 725 3.89 / 661.46 5 82
5 13 877.44 20 14.68 1688 496 4.39 / 661.95 5 91
6 13 121.48 20 14.91 525 157 4.55 / 662.11 5 90
7 8 0.04 279 14.87 336 1394 5.94 / 663.50 5 132
Average= 47.39
(KJ/cycle)

Cycle 114 GMT 4/11/2022 21:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 37 14.84 505 277 0.28 / 651.74 5 46
2 7 2011.28 40 14.66 3328 1952 2.23 / 653.69 46 66
3 13 1925.20 20 14.61 3214 939 3.17 / 654.63 5 71
4 13 1489.16 20 14.60 2594 757 3.93 / 655.39 5 80
5 13 948.88 20 14.66 1789 525 4.45 / 655.92 5 91
6 13 291.24 20 14.85 788 234 4.68 / 656.15 5 95
7 8 0.20 282 14.87 337 1413 6.10 / 657.56 5 131
Average= 50.58
(KJ/cycle)

Cycle 113 GMT 26/10/2022 0:24: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 37 14.85 514 282 0.28 / 645.71 5 51
2 7 2009.60 40 14.65 3324 1948 2.23 / 647.66 51 66
3 13 1911.88 20 14.62 3213 939 3.17 / 648.60 5 73
4 13 1398.72 20 14.60 2465 720 3.89 / 649.32 5 82
5 13 878.40 20 14.68 1682 494 4.38 / 649.81 5 91
6 13 209.04 20 14.87 676 201 4.58 / 650.01 5 95
7 8 0.04 289 14.86 338 1452 6.04 / 651.47 5 131
Average= 54.29
(KJ/cycle)

Cycle 112 GMT 16/10/2022 3:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.92 37 14.85 500 275 0.27 / 639.74 5 44
2 7 2017.52 41 14.65 3330 2000 2.27 / 641.74 44 67
3 13 1931.04 20 14.61 3231 944 3.22 / 642.68 5 70
4 13 1409.32 20 14.61 2479 724 3.94 / 643.40 5 82
5 13 866.08 20 14.68 1659 487 4.43 / 643.89 5 91
6 13 56.72 20 14.92 424 127 4.56 / 644.02 5 89
7 8 0.20 285 14.87 333 1411 5.97 / 645.43 5 133
Average= 58.68
(KJ/cycle)

Cycle 111 GMT 6/10/2022 6:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 37 14.84 513 282 0.28 / 633.64 5 44
2 7 2012.60 40 14.65 3336 1955 2.24 / 635.59 44 68
3 13 1921.84 20 14.62 3229 944 3.18 / 636.54 5 71
4 13 1500.52 20 14.59 2612 762 3.94 / 637.30 5 81
5 13 956.68 20 14.65 1807 529 4.47 / 637.83 5 92
6 13 288.32 20 14.84 787 234 4.71 / 638.06 5 92
7 8 0.08 280 14.86 336 1398 6.10 / 639.46 5 133
Average= 63.95
(KJ/cycle)

Cycle 110 GMT 26/ 9/2022 9:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 37 14.85 505 277 0.28 / 627.67 5 40
2 7 2004.64 40 14.64 3311 1939 2.22 / 629.61 40 67
3 13 1909.40 20 14.61 3203 936 3.15 / 630.54 5 73
4 13 1394.84 20 14.60 2466 720 3.87 / 631.27 5 81
5 13 972.40 20 14.64 1826 535 4.41 / 631.80 5 91
6 13 196.80 20 14.87 641 191 4.60 / 631.99 5 91
7 8 -0.04 277 14.86 332 1367 5.96 / 633.36 5 131
Average= 70.37
(KJ/cycle)

Cycle 109 GMT 16/ 9/2022 12:22:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.84 37 14.85 500 275 0.27 / 621.67 5 39
2 7 2003.96 40 14.66 3315 1944 2.22 / 623.61 6 65
3 13 1917.52 20 14.61 3211 938 3.16 / 624.55 5 70
4 13 1600.00 20 14.58 2760 805 3.96 / 625.35 5 80
5 13 1039.96 20 14.63 1918 561 4.52 / 625.91 5 87
6 13 161.88 20 14.89 587 175 4.70 / 626.09 5 84
7 8 0.08 264 14.87 332 1303 6.00 / 627.39 5 130
Average= 78.42
(KJ/cycle)

Cycle 108 GMT 6/ 9/2022 15:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.60 37 14.88 501 276 0.28 / 615.66 6 39
2 7 2013.16 40 14.65 3324 1948 2.22 / 617.61 39 65
3 13 1925.28 20 14.62 3214 940 3.16 / 618.55 5 69
4 13 1513.56 20 14.59 2629 767 3.93 / 619.32 5 79
5 13 957.20 20 14.65 1788 524 4.45 / 619.84 5 87
6 13 395.80 20 14.80 945 280 4.73 / 620.12 5 89
7 8 0.16 259 14.86 330 1270 6.00 / 621.39 5 137
Average= 88.77
(KJ/cycle)

Cycle 107 GMT 27/ 8/2022 18:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 37 14.87 494 272 0.27 / 609.69 6 37
2 7 2017.20 40 14.66 3332 1954 2.23 / 611.65 37 67
3 13 1935.52 20 14.61 3245 948 3.17 / 612.60 5 68
4 13 1603.64 20 14.58 2760 805 3.98 / 613.40 5 77
5 13 1034.92 20 14.63 1917 561 4.54 / 613.96 5 87
6 13 161.08 20 14.90 583 174 4.71 / 614.14 5 78
7 8 0.00 257 14.89 327 1251 5.96 / 615.39 5 129
Average= 102.56
(KJ/cycle)

Cycle 106 GMT 17/ 8/2022 21:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 37 14.88 489 269 0.27 / 603.68 5 37
2 7 2010.32 41 14.65 3314 1991 2.26 / 605.67 6 66
3 13 1916.80 20 14.62 3215 940 3.20 / 606.61 5 69
4 13 1485.56 20 14.60 2580 753 3.95 / 607.36 5 80
5 13 931.92 20 14.66 1773 520 4.47 / 607.88 5 89
6 13 374.88 20 14.82 920 273 4.75 / 608.15 5 92
7 8 0.16 261 14.88 327 1270 6.02 / 609.42 5 132
Average= 121.88
(KJ/cycle)

Cycle 105 GMT 8/ 8/2022 1: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 37 14.87 499 275 0.27 / 597.94 5 36
2 7 2005.48 40 14.66 3312 1942 2.22 / 599.89 36 67
3 13 1915.12 20 14.62 3201 936 3.15 / 600.82 5 70
4 13 1399.04 20 14.61 2468 721 3.87 / 601.54 5 83
5 13 866.00 20 14.68 1658 487 4.36 / 602.03 5 90
6 13 56.24 20 14.93 410 122 4.48 / 602.15 5 84
7 8 0.28 257 14.89 328 1255 5.74 / 603.41 5 129
Average= 150.85
(KJ/cycle)

Cycle 104 GMT 29/ 7/2022 3:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 37 14.87 513 282 0.28 / 592.01 6 36
2 7 2011.24 40 14.66 3322 1948 2.23 / 593.96 36 65
3 13 1913.88 20 14.63 3203 937 3.17 / 594.89 5 69
4 13 1589.40 20 14.59 2741 800 3.97 / 595.69 5 75
5 13 928.36 20 14.67 1754 515 4.48 / 596.21 5 89
6 13 168.56 20 14.89 593 177 4.66 / 596.38 5 83
7 8 0.04 265 14.88 326 1285 5.94 / 597.67 5 146
Average= 199.22
(KJ/cycle)

Cycle 103 GMT 19/ 7/2022 7: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 37 14.88 503 277 0.28 / 586.17 6 34
2 7 2010.92 40 14.66 3314 1943 2.22 / 588.11 34 65
3 13 1920.20 20 14.62 3212 939 3.16 / 589.05 5 70
4 13 1490.44 20 14.59 2597 758 3.92 / 589.81 5 79
5 13 843.20 20 14.69 1616 475 4.39 / 590.28 5 87
6 13 96.84 20 14.92 476 142 4.53 / 590.43 5 77
7 8 -0.08 266 14.89 328 1299 5.83 / 591.72 5 138
Average= 295.86
(KJ/cycle)

Cycle 102 GMT 9/ 7/2022 9:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 37 14.88 482 265 0.27 / 580.34 6 30
2 7 2015.24 40 14.66 3318 1946 2.21 / 582.28 30 64
3 13 1928.44 20 14.61 3210 938 3.15 / 583.22 5 69
4 13 1510.36 20 14.59 2635 769 3.92 / 583.99 5 77
5 13 976.88 20 14.64 1842 539 4.46 / 584.53 5 88
6 13 25.36 20 14.94 357 107 4.56 / 584.64 5 73
7 8 0.24 261 14.89 323 1255 5.82 / 585.89 6 129
Average= 585.89
(KJ/cycle)

Cycle 100 GMT 19/ 6/2022 15:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 37 14.88 491 270 0.27 / 574.52 6 29
2 7 2012.92 40 14.67 3313 1944 2.21 / 576.47 29 66
3 13 1928.80 20 14.62 3219 941 3.16 / 577.41 5 69
4 13 1500.88 20 14.60 2605 761 3.92 / 578.17 5 76
5 13 857.84 20 14.68 1637 481 4.40 / 578.65 5 88
6 13 120.00 20 14.92 509 152 4.55 / 578.80 5 77
7 13 25.28 20 14.94 359 107 4.66 / 578.91 5 70
8 8 0.08 242 14.89 323 1164 5.82 / 580.07 5 132
Average= 5.74
(KJ/cycle)

Cycle 99 GMT 9/ 6/2022 18:31: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 37 14.89 477 263 0.26 / 568.65 6 25
2 7 2012.16 40 14.67 3292 1932 2.19 / 570.58 25 63
3 13 1922.60 20 14.63 3193 934 3.13 / 571.52 5 68
4 13 1501.92 20 14.60 2612 763 3.89 / 572.28 5 77
5 13 963.12 20 14.66 1805 529 4.42 / 572.81 5 87
6 13 184.44 20 14.89 616 183 4.60 / 572.99 5 76
7 8 0.28 265 14.89 319 1259 5.86 / 574.25 5 147
Average= 5.74
(KJ/cycle)

Cycle 98 GMT 30/ 5/2022 21:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 37 14.89 501 276 0.28 / 562.72 6 28
2 7 2012.68 40 14.66 3315 1944 2.22 / 564.66 28 65
3 13 1924.36 20 14.63 3206 938 3.16 / 565.60 5 69
4 13 1502.80 20 14.60 2607 761 3.92 / 566.36 5 77
5 13 1061.60 20 14.63 1955 572 4.49 / 566.93 5 87
6 13 169.52 20 14.90 591 176 4.67 / 567.11 5 78
7 13 32.84 20 14.93 373 111 4.78 / 567.22 5 77
8 8 -0.04 246 14.89 319 1168 5.95 / 568.39 5 139
Average= 5.74
(KJ/cycle)

Cycle 97 GMT 21/ 5/2022 0:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.76 37 14.90 492 271 0.27 / 556.90 6 21
2 7 2005.24 40 14.66 3305 1938 2.21 / 558.83 21 66
3 13 1914.52 20 14.62 3200 936 3.14 / 559.77 5 69
4 13 1484.20 20 14.60 2602 760 3.90 / 560.53 5 79
5 13 843.40 20 14.69 1625 477 4.38 / 561.01 5 89
6 13 87.16 20 14.93 464 139 4.52 / 561.15 5 73
7 8 0.04 268 14.89 325 1297 5.82 / 562.44 5 130
Average= 5.74
(KJ/cycle)

Cycle 96 GMT 11/ 5/2022 3:32: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.20 36 14.89 493 264 0.26 / 551.06 6 25
2 7 2011.00 41 14.66 3305 1987 2.25 / 553.05 25 65
3 13 1918.36 20 14.63 3198 936 3.19 / 553.98 5 69
4 13 1489.40 20 14.60 2578 753 3.94 / 554.74 5 77
5 13 851.60 20 14.69 1630 479 4.42 / 555.22 5 87
6 13 53.52 20 14.94 401 120 4.54 / 555.34 5 74
7 8 0.04 267 14.90 324 1289 5.83 / 556.62 5 137
Average= 5.74
(KJ/cycle)

Cycle 95 GMT 1/ 5/2022 6:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.44 37 14.90 490 270 0.27 / 545.11 6 22
2 7 2013.80 40 14.67 3314 1945 2.21 / 547.05 22 65
3 13 1921.32 20 14.64 3204 938 3.15 / 547.99 5 68
4 13 1606.56 20 14.59 2753 803 3.96 / 548.79 5 76
5 13 950.84 20 14.67 1781 523 4.48 / 549.32 5 87
6 13 180.08 20 14.90 615 183 4.66 / 549.50 5 81
7 8 0.00 268 14.89 325 1297 5.96 / 550.80 5 140
Average= 5.74
(KJ/cycle)

Cycle 94 GMT 21/ 4/2022 9:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 37 14.89 471 259 0.26 / 539.24 6 19
2 7 2013.16 40 14.67 3311 1943 2.20 / 541.18 19 64
3 13 1923.76 20 14.63 3215 941 3.14 / 542.12 5 68
4 13 1498.16 20 14.61 2590 757 3.90 / 542.88 5 79
5 13 961.08 20 14.66 1801 528 4.43 / 543.41 5 86
6 13 94.72 20 14.93 475 142 4.57 / 543.55 5 77
7 8 0.08 265 14.90 327 1291 5.86 / 544.84 5 130
Average= 5.74
(KJ/cycle)

Cycle 93 GMT 11/ 4/2022 12:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.04 36 14.89 494 265 0.26 / 533.38 6 20
2 7 2013.12 40 14.67 3303 1938 2.20 / 535.32 20 65
3 13 1921.24 20 14.63 3198 936 3.14 / 536.26 5 69
4 13 1493.24 20 14.61 2591 757 3.90 / 537.01 5 78
5 13 951.32 20 14.66 1787 524 4.42 / 537.54 5 87
6 13 93.88 20 14.93 477 142 4.56 / 537.68 5 76
7 8 0.28 268 14.89 325 1297 5.86 / 538.98 5 141
Average= 5.73
(KJ/cycle)

Cycle 92 GMT 1/ 4/2022 15:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 36 14.90 487 261 0.26 / 527.51 6 18
2 7 2005.08 40 14.67 3301 1937 2.20 / 529.44 18 65
3 13 1914.32 20 14.64 3201 937 3.14 / 530.38 5 68
4 13 1400.32 20 14.62 2466 721 3.86 / 531.10 5 79
5 13 966.24 20 14.65 1810 530 4.39 / 531.63 5 87
6 13 193.20 20 14.89 633 189 4.58 / 531.82 5 81
7 8 0.04 270 14.88 323 1298 5.87 / 533.12 5 138
Average= 5.73
(KJ/cycle)

Cycle 91 GMT 22/ 3/2022 18:19: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 36 14.90 485 260 0.26 / 521.65 6 16
2 7 2011.04 40 14.67 3310 1942 2.20 / 523.59 16 63
3 13 1920.04 20 14.63 3207 938 3.14 / 524.53 5 68
4 13 1495.80 20 14.60 2610 762 3.90 / 525.29 5 77
5 13 862.04 20 14.69 1655 486 4.39 / 525.78 5 88
6 13 210.44 20 14.88 663 197 4.59 / 525.97 5 78
7 8 0.12 265 14.89 322 1271 5.86 / 527.25 5 130
Average= 5.73
(KJ/cycle)

Cycle 90 GMT 12/ 3/2022 21:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.28 36 14.90 495 266 0.27 / 515.82 6 20
2 7 2003.68 41 14.67 3299 1984 2.25 / 517.81 20 67
3 13 1912.08 20 14.63 3207 938 3.19 / 518.75 5 67
4 13 1391.52 20 14.62 2429 710 3.90 / 519.46 5 78
5 13 862.32 20 14.69 1652 485 4.38 / 519.94 5 87
6 13 101.48 20 14.92 487 145 4.53 / 520.09 5 75
7 13 20.72 20 14.94 361 108 4.64 / 520.19 5 70
8 8 0.08 246 14.89 326 1194 5.83 / 521.39 5 131
Average= 5.73
(KJ/cycle)

Cycle 89 GMT 3/ 3/2022 0:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 36 14.91 490 263 0.26 / 509.96 6 16
2 7 2008.36 40 14.67 3307 1941 2.20 / 511.90 16 66
3 13 1915.92 20 14.64 3191 934 3.14 / 512.83 5 68
4 13 1491.36 20 14.60 2595 758 3.90 / 513.59 5 78
5 13 934.00 20 14.67 1757 516 4.41 / 514.10 5 88
6 13 76.52 20 14.94 448 134 4.54 / 514.24 5 76
7 13 16.16 20 14.95 355 106 4.65 / 514.34 5 73
8 8 0.04 246 14.89 331 1212 5.86 / 515.56 6 136
Average= 5.73
(KJ/cycle)

Cycle 88 GMT 21/ 2/2022 3:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.16 36 14.89 501 269 0.27 / 504.12 6 15
2 7 2004.16 40 14.68 3297 1936 2.20 / 506.06 15 64
3 13 1912.52 20 14.64 3205 938 3.14 / 507.00 5 70
4 13 1485.04 20 14.62 2583 755 3.90 / 507.75 5 77
5 13 932.56 20 14.68 1760 517 4.41 / 508.27 5 86
6 13 46.92 20 14.95 396 118 4.53 / 508.39 5 74
7 8 0.08 267 14.90 328 1305 5.84 / 509.69 5 132
Average= 5.73
(KJ/cycle)

Cycle 87 GMT 11/ 2/2022 6:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 36 14.90 498 267 0.27 / 498.34 6 17
2 7 2013.96 40 14.68 3303 1940 2.21 / 500.28 17 63
3 13 1927.88 20 14.64 3191 934 3.14 / 501.21 5 70
4 13 1405.44 20 14.62 2472 723 3.86 / 501.93 5 78
5 13 878.64 20 14.69 1670 491 4.35 / 502.42 5 87
6 13 58.48 20 14.94 413 123 4.48 / 502.55 5 72
7 8 0.08 267 14.89 329 1308 5.79 / 503.86 5 131
Average= 5.73
(KJ/cycle)

Cycle 86 GMT 1/ 2/2022 9: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 36 14.91 496 266 0.27 / 492.54 6 21
2 7 2009.64 40 14.67 3314 1945 2.21 / 494.48 21 64
3 13 1918.52 20 14.64 3204 938 3.15 / 495.42 5 70
4 13 1395.00 20 14.62 2462 720 3.87 / 496.14 5 80
5 13 858.16 20 14.69 1653 486 4.35 / 496.62 5 90
6 13 99.72 20 14.93 485 145 4.50 / 496.77 5 75
7 8 -0.04 267 14.90 327 1301 5.80 / 498.07 5 131
Average= 5.72
(KJ/cycle)

Cycle 85 GMT 22/ 1/2022 11:52: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.88 36 14.89 502 269 0.27 / 486.64 6 22
2 7 2012.96 40 14.68 3312 1945 2.21 / 488.59 22 65
3 13 1920.92 20 14.65 3205 939 3.15 / 489.52 5 70
4 13 1596.20 20 14.60 2747 802 3.96 / 490.33 5 75
5 13 843.12 20 14.71 1629 479 4.43 / 490.81 5 87
6 13 97.72 20 14.94 485 145 4.58 / 490.95 5 75
7 8 0.16 268 14.91 330 1319 5.90 / 492.27 5 135
Average= 5.72
(KJ/cycle)

Cycle 84 GMT 12/ 1/2022 14:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.48 36 14.90 504 270 0.27 / 480.73 6 25
2 7 2009.00 41 14.67 3319 1996 2.27 / 482.73 25 65
3 13 1917.92 20 14.63 3208 939 3.21 / 483.67 5 68
4 13 1391.48 20 14.63 2445 715 3.92 / 484.38 5 79
5 13 967.56 20 14.66 1828 536 4.46 / 484.92 5 87
6 13 89.00 20 14.94 475 142 4.60 / 485.06 5 78
7 8 -0.04 265 14.90 332 1311 5.91 / 486.37 5 141
Average= 5.72
(KJ/cycle)

Cycle 83 GMT 2/ 1/2022 17:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.40 36 14.89 507 272 0.27 / 474.94 6 23
2 7 2009.28 40 14.68 3286 1930 2.20 / 476.87 23 68
3 13 1915.80 20 14.65 3206 939 3.14 / 477.81 5 70
4 13 1485.80 20 14.62 2575 753 3.89 / 478.56 5 78
5 13 839.16 20 14.71 1622 477 4.37 / 479.04 5 92
6 13 89.28 20 14.94 476 142 4.51 / 479.18 5 76
7 8 0.12 259 14.91 332 1282 5.80 / 480.46 5 135
Average= 5.72
(KJ/cycle)

Cycle 82 GMT 23/12/2021 20:41: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.32 36 14.90 492 264 0.26 / 469.09 6 28
2 7 2015.20 40 14.68 3316 1947 2.21 / 471.03 28 66
3 13 1927.44 20 14.64 3217 942 3.15 / 471.97 5 70
4 13 1499.40 20 14.61 2613 764 3.92 / 472.74 5 78
5 13 839.52 20 14.71 1614 475 4.39 / 473.21 5 90
6 13 90.44 20 14.94 475 142 4.53 / 473.36 5 77
7 8 0.00 266 14.90 331 1312 5.85 / 474.67 5 134
Average= 5.72
(KJ/cycle)

Cycle 81 GMT 13/12/2021 23:38: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 36 14.90 514 276 0.28 / 463.27 6 32
2 7 2007.44 40 14.69 3318 1950 2.23 / 465.22 32 67
3 13 1919.44 20 14.64 3220 943 3.17 / 466.16 5 69
4 13 1403.12 20 14.64 2462 721 3.89 / 466.88 5 81
5 13 885.92 20 14.69 1696 498 4.39 / 467.38 5 91
6 13 64.72 20 14.95 430 129 4.52 / 467.51 5 76
7 8 0.00 265 14.91 333 1316 5.83 / 468.82 5 131
Average= 5.72
(KJ/cycle)

Cycle 80 GMT 4/12/2021 2:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.68 36 14.89 512 274 0.27 / 457.29 6 30
2 7 2016.68 41 14.68 3330 2004 2.28 / 459.29 30 65
3 13 1927.76 20 14.64 3231 946 3.22 / 460.24 5 68
4 13 1508.36 20 14.61 2627 768 3.99 / 461.01 5 77
5 13 949.40 20 14.68 1793 526 4.52 / 461.53 5 88
6 13 88.80 20 14.94 476 142 4.66 / 461.68 5 75
7 8 0.28 261 14.90 338 1314 5.98 / 462.99 5 134
Average= 5.72
(KJ/cycle)

Cycle 79 GMT 24/11/2021 5:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 36 14.89 507 272 0.27 / 451.37 6 31
2 7 2007.00 40 14.69 3314 1947 2.22 / 453.32 31 64
3 13 1915.80 20 14.65 3201 938 3.16 / 454.25 5 69
4 13 1491.76 20 14.63 2595 759 3.92 / 455.01 5 79
5 13 950.84 20 14.68 1794 527 4.44 / 455.54 5 86
6 13 90.08 20 14.95 478 143 4.59 / 455.68 5 79
7 8 -0.16 263 14.90 340 1332 5.92 / 457.01 5 138
Average= 5.71
(KJ/cycle)

Cycle 78 GMT 14/11/2021 8:28: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 36 14.89 515 276 0.28 / 445.59 6 30
2 7 2005.44 40 14.68 3311 1944 2.22 / 447.54 30 67
3 13 1915.36 20 14.65 3200 938 3.16 / 448.47 5 70
4 13 1385.60 20 14.64 2441 715 3.87 / 449.19 5 80
5 13 763.16 20 14.74 1511 445 4.32 / 449.63 5 90
6 13 110.52 20 14.94 511 153 4.47 / 449.79 5 78
7 8 0.00 261 14.90 337 1311 5.78 / 451.10 5 134
Average= 5.71
(KJ/cycle)

Cycle 77 GMT 4/11/2021 11:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.36 37 14.91 508 280 0.28 / 439.68 6 34
2 7 2006.56 40 14.69 3313 1947 2.23 / 441.63 34 65
3 13 1922.12 20 14.65 3218 943 3.17 / 442.57 5 70
4 13 1515.92 20 14.63 2621 767 3.94 / 443.34 5 80
5 13 878.32 20 14.71 1682 495 4.43 / 443.83 5 90
6 13 111.56 20 14.94 511 153 4.58 / 443.99 5 81
7 8 0.12 265 14.91 336 1328 5.91 / 445.32 5 133
Average= 5.71
(KJ/cycle)

Cycle 76 GMT 25/10/2021 14:13: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 37 14.90 506 279 0.28 / 433.80 6 34
2 7 2012.44 40 14.68 3326 1953 2.23 / 435.76 34 67
3 13 1928.72 20 14.65 3218 943 3.17 / 436.70 5 70
4 13 1518.52 20 14.62 2631 769 3.94 / 437.47 5 80
5 13 870.36 20 14.70 1674 492 4.44 / 437.96 5 90
6 13 64.04 20 14.96 433 130 4.57 / 438.09 5 79
7 8 0.16 261 14.92 337 1312 5.88 / 439.40 5 129
Average= 5.71
(KJ/cycle)

Cycle 75 GMT 15/10/2021 17: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.40 37 14.90 515 284 0.28 / 427.84 6 39
2 7 2004.52 41 14.69 3318 1998 2.28 / 429.84 39 67
3 13 1909.20 20 14.66 3203 939 3.22 / 430.78 5 70
4 13 1382.40 20 14.64 2446 716 3.94 / 431.50 5 81
5 13 1057.40 20 14.66 1945 570 4.51 / 432.07 5 88
6 13 84.48 20 14.95 469 140 4.65 / 432.21 5 78
7 8 -0.04 261 14.91 339 1319 5.97 / 433.53 5 133
Average= 5.70
(KJ/cycle)

Cycle 74 GMT 5/10/2021 20: 1: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.56 37 14.90 509 281 0.28 / 422.08 6 40
2 7 2012.72 40 14.69 3322 1952 2.23 / 424.03 40 65
3 13 1923.36 20 14.65 3218 943 3.18 / 424.97 5 71
4 13 1396.20 20 14.65 2457 720 3.90 / 425.69 5 82
5 13 866.00 20 14.72 1668 491 4.39 / 426.18 5 91
6 13 28.64 20 14.98 377 113 4.50 / 426.30 5 79
7 8 -0.04 253 14.92 334 1261 5.76 / 427.56 5 133
Average= 5.70
(KJ/cycle)

Cycle 73 GMT 25/ 9/2021 22:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 37 14.90 515 284 0.28 / 416.26 6 39
2 7 2004.56 40 14.70 3313 1948 2.23 / 418.21 39 67
3 13 1918.28 20 14.66 3214 942 3.17 / 419.15 5 70
4 13 1397.04 20 14.65 2445 716 3.89 / 419.87 5 82
5 13 861.28 20 14.72 1656 488 4.38 / 420.36 5 90
6 13 98.76 20 14.95 493 147 4.53 / 420.51 5 81
7 8 0.16 257 14.92 337 1292 5.82 / 421.80 5 129
Average= 5.70
(KJ/cycle)

Cycle 72 GMT 16/ 9/2021 1:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.00 37 14.91 512 282 0.28 / 410.37 6 39
2 7 2015.20 40 14.69 3326 1954 2.24 / 412.32 39 67
3 13 1925.16 20 14.66 3201 939 3.18 / 413.26 5 70
4 13 1406.00 20 14.65 2465 722 3.90 / 413.99 5 82
5 13 985.64 20 14.68 1842 541 4.44 / 414.53 5 89
6 13 188.60 20 14.92 633 189 4.63 / 414.72 5 84
7 8 0.16 253 14.92 335 1265 5.89 / 415.98 5 131
Average= 5.70
(KJ/cycle)

Cycle 71 GMT 6/ 9/2021 4:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 37 14.89 508 280 0.28 / 404.57 5 40
2 7 2006.96 40 14.70 3321 1953 2.23 / 406.52 40 67
3 13 1909.64 20 14.66 3187 934 3.17 / 407.45 5 70
4 13 1479.08 20 14.64 2578 755 3.92 / 408.21 5 81
5 13 824.88 20 14.74 1592 469 4.39 / 408.68 5 89
6 13 23.08 20 14.98 366 110 4.50 / 408.79 5 77
7 8 0.04 261 14.92 334 1301 5.80 / 410.09 5 135
Average= 5.70
(KJ/cycle)

Cycle 70 GMT 27/ 8/2021 8: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 36 14.91 509 273 0.27 / 398.62 6 37
2 7 2003.60 40 14.71 3316 1951 2.22 / 400.58 5 64
3 13 1915.00 20 14.66 3196 937 3.16 / 401.51 5 70
4 13 1482.56 20 14.65 2582 757 3.92 / 402.27 5 80
5 13 847.92 20 14.73 1628 480 4.40 / 402.75 5 91
6 13 301.84 20 14.88 804 239 4.64 / 402.99 5 88
7 8 -0.04 263 14.91 331 1298 5.93 / 404.29 5 133
Average= 5.69
(KJ/cycle)

Cycle 69 GMT 17/ 8/2021 11: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 36 14.91 505 271 0.27 / 392.86 6 39
2 7 2007.04 40 14.70 3320 1952 2.22 / 394.82 39 66
3 13 1914.52 20 14.66 3197 937 3.16 / 395.75 5 71
4 13 1403.24 20 14.65 2459 720 3.88 / 396.47 5 82
5 13 867.28 20 14.72 1661 489 4.37 / 396.96 5 90
6 8 0.12 280 14.93 332 1388 5.76 / 398.35 5 130
Average= 5.69
(KJ/cycle)

Cycle 68 GMT 7/ 8/2021 14: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.28 36 14.92 502 270 0.27 / 387.00 6 36
2 7 2013.68 40 14.70 3329 1957 2.23 / 388.95 36 65
3 13 1920.04 20 14.67 3221 945 3.17 / 389.90 5 70
4 13 1504.84 20 14.64 2623 768 3.94 / 390.67 5 79
5 13 868.52 20 14.73 1672 493 4.43 / 391.16 5 89
6 13 99.88 20 14.96 493 148 4.58 / 391.31 5 78
7 8 0.40 261 14.93 330 1286 5.87 / 392.59 5 136
Average= 5.69
(KJ/cycle)

Cycle 67 GMT 28/ 7/2021 17: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.88 36 14.92 522 280 0.28 / 381.13 6 34
2 7 2011.72 40 14.71 3341 1966 2.25 / 383.09 34 65
3 13 1919.92 20 14.67 3213 943 3.19 / 384.04 5 70
4 13 1397.36 20 14.66 2462 722 3.91 / 384.76 5 81
5 13 963.96 20 14.69 1819 534 4.45 / 385.29 5 88
6 13 99.36 20 14.96 488 146 4.59 / 385.44 5 78
7 8 0.36 261 14.93 331 1290 5.88 / 386.73 5 136
Average= 5.69
(KJ/cycle)

Cycle 66 GMT 18/ 7/2021 20:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.60 36 14.92 501 269 0.27 / 375.16 6 35
2 7 2010.48 40 14.71 3326 1957 2.23 / 377.12 35 65
3 13 1919.40 20 14.67 3211 942 3.17 / 378.06 5 72
4 13 1492.80 20 14.65 2601 762 3.93 / 378.82 5 80
5 13 1048.92 20 14.68 1944 571 4.50 / 379.40 5 87
6 13 76.48 20 14.98 449 135 4.64 / 379.53 5 79
7 13 16.96 20 14.98 366 110 4.75 / 379.64 5 75
8 8 -0.16 242 14.93 334 1207 5.95 / 380.85 5 139
Average= 5.68
(KJ/cycle)

Cycle 65 GMT 8/ 7/2021 23:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 36 14.92 511 274 0.27 / 369.16 6 37
2 7 2014.96 40 14.71 3337 1963 2.24 / 371.12 37 66
3 13 1921.48 20 14.67 3231 948 3.19 / 372.07 5 71
4 13 1606.24 20 14.64 2774 812 4.00 / 372.88 5 76
5 13 942.96 20 14.72 1783 525 4.52 / 373.40 5 89
6 13 170.40 20 14.94 612 183 4.71 / 373.59 5 80
7 8 0.24 259 14.93 338 1307 6.01 / 374.89 5 131
Average= 5.68
(KJ/cycle)

Cycle 64 GMT 29/ 6/2021 2:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.32 36 14.93 502 270 0.27 / 363.28 6 34
2 7 2006.56 40 14.72 3324 1957 2.23 / 365.23 34 66
3 13 1912.48 20 14.67 3205 940 3.17 / 366.17 5 70
4 13 1372.64 20 14.67 2435 714 3.88 / 366.89 5 82
5 13 932.68 20 14.71 1771 521 4.40 / 367.41 5 89
6 13 80.32 20 14.98 462 138 4.54 / 367.55 5 80
7 8 0.00 263 14.93 340 1335 5.88 / 368.88 5 133
Average= 5.68
(KJ/cycle)

Cycle 63 GMT 19/ 6/2021 5:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 36 14.94 518 279 0.28 / 357.40 6 35
2 7 2007.56 40 14.72 3313 1951 2.23 / 359.35 35 65
3 13 1914.24 20 14.67 3215 943 3.17 / 360.29 5 70
4 13 1495.88 20 14.65 2618 767 3.94 / 361.06 5 80
5 13 933.08 20 14.72 1765 520 4.46 / 361.58 5 90
6 13 79.88 20 14.98 461 138 4.60 / 361.72 5 78
7 8 0.12 257 14.94 336 1290 5.89 / 363.01 5 131
Average= 5.67
(KJ/cycle)

Cycle 62 GMT 9/ 6/2021 8:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 36 14.94 513 276 0.28 / 351.48 6 31
2 7 2009.48 40 14.72 3333 1962 2.24 / 353.44 31 67
3 13 1911.48 20 14.68 3187 936 3.17 / 354.38 5 71
4 13 1491.84 20 14.66 2605 764 3.94 / 355.14 5 80
5 13 952.08 20 14.72 1798 529 4.47 / 355.67 5 89
6 13 89.88 20 14.98 481 144 4.61 / 355.82 5 79
7 8 0.28 257 14.95 339 1302 5.91 / 357.12 5 130
Average= 5.67
(KJ/cycle)

Cycle 61 GMT 30/ 5/2021 11:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.36 36 14.95 506 272 0.27 / 345.61 6 29
2 7 2012.24 40 14.72 3323 1957 2.23 / 347.56 29 68
3 13 1918.60 20 14.68 3217 945 3.17 / 348.51 5 70
4 13 1486.44 20 14.66 2596 761 3.93 / 349.27 5 81
5 13 930.20 20 14.73 1755 517 4.45 / 349.79 5 90
6 13 71.68 20 14.99 445 133 4.59 / 349.92 5 79
7 13 16.60 20 15.00 362 109 4.69 / 350.03 5 79
8 8 0.04 233 14.94 338 1177 5.87 / 351.20 5 132
Average= 5.66
(KJ/cycle)

Cycle 60 GMT 20/ 5/2021 14:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 36 14.95 508 273 0.27 / 339.71 6 28
2 7 2010.32 40 14.72 3330 1961 2.23 / 341.67 28 65
3 13 1922.84 20 14.69 3216 945 3.18 / 342.62 5 71
4 13 1501.04 20 14.66 2618 768 3.95 / 343.39 5 81
5 13 952.16 20 14.73 1802 531 4.48 / 343.92 5 90
6 13 98.16 20 14.99 489 147 4.62 / 344.06 5 79
7 8 -0.24 255 14.96 333 1270 5.89 / 345.33 5 131
Average= 5.66
(KJ/cycle)

Cycle 59 GMT 10/ 5/2021 17:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.92 36 14.95 497 267 0.27 / 333.74 6 26
2 7 2006.36 41 14.72 3329 2009 2.28 / 335.75 26 67
3 13 1916.16 20 14.68 3201 940 3.22 / 336.69 5 72
4 13 1473.32 20 14.67 2584 758 3.97 / 337.45 5 80
5 13 917.24 20 14.74 1749 516 4.49 / 337.96 5 90
6 13 77.32 20 15.00 463 139 4.63 / 338.10 5 79
7 8 0.12 263 14.96 340 1338 5.97 / 339.44 5 130
Average= 5.66
(KJ/cycle)

Cycle 58 GMT 30/ 4/2021 20:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.08 36 14.96 495 267 0.27 / 327.84 6 27
2 7 2010.72 40 14.72 3334 1963 2.23 / 329.80 27 67
3 13 1921.72 20 14.69 3225 948 3.18 / 330.75 5 71
4 13 1404.52 20 14.68 2478 728 3.90 / 331.48 5 81
5 13 869.28 20 14.76 1671 493 4.40 / 331.97 5 90
6 13 113.16 20 14.99 519 156 4.55 / 332.12 5 79
7 8 0.20 265 14.96 340 1348 5.90 / 333.47 5 142
Average= 5.65
(KJ/cycle)

Cycle 57 GMT 20/ 4/2021 23:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 35 14.97 510 267 0.27 / 321.86 6 23
2 7 2004.32 40 14.73 3322 1957 2.22 / 323.82 23 68
3 13 1923.36 20 14.70 3220 947 3.17 / 324.77 5 71
4 13 1496.12 20 14.67 2616 768 3.94 / 325.53 5 81
5 13 950.64 20 14.74 1800 531 4.47 / 326.06 5 90
6 13 89.24 20 15.01 485 146 4.61 / 326.21 5 79
7 13 20.76 20 15.02 376 113 4.73 / 326.32 5 76
8 8 0.12 246 14.97 339 1248 5.98 / 327.57 5 141
Average= 5.65
(KJ/cycle)

Cycle 56 GMT 11/ 4/2021 2:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.60 35 14.99 495 260 0.26 / 316.00 6 23
2 7 2005.20 40 14.73 3323 1958 2.22 / 317.96 23 68
3 13 1909.40 20 14.70 3199 941 3.16 / 318.90 5 72
4 13 1379.60 20 14.70 2445 719 3.88 / 319.62 5 83
5 13 945.40 20 14.75 1788 527 4.40 / 320.14 5 89
6 13 45.32 20 15.03 406 122 4.53 / 320.26 5 75
7 8 0.16 265 14.98 335 1330 5.86 / 321.59 5 129
Average= 5.64
(KJ/cycle)

Cycle 55 GMT 1/ 4/2021 5:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 36 15.00 489 264 0.26 / 310.14 6 23
2 7 2005.72 41 14.73 3328 2010 2.27 / 312.15 23 66
3 13 1914.64 20 14.70 3213 945 3.22 / 313.10 5 72
4 13 1396.96 20 14.70 2459 723 3.94 / 313.82 5 83
5 13 858.88 20 14.78 1651 488 4.43 / 314.31 5 90
6 13 53.88 20 15.03 419 126 4.56 / 314.43 5 76
7 8 0.00 263 14.99 331 1305 5.86 / 315.74 5 132
Average= 5.64
(KJ/cycle)

Cycle 54 GMT 22/ 3/2021 8: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 36 14.99 510 275 0.28 / 304.24 6 23
2 7 2006.56 41 14.74 3308 1999 2.27 / 306.24 23 68
3 13 1915.80 20 14.70 3209 943 3.22 / 307.18 5 71
4 13 1489.96 20 14.69 2601 764 3.98 / 307.95 5 81
5 13 929.68 20 14.77 1765 521 4.50 / 308.47 5 89
6 13 70.16 20 15.03 449 135 4.64 / 308.60 5 79
7 8 -0.12 257 15.00 331 1276 5.91 / 309.88 5 138
Average= 5.63
(KJ/cycle)

Cycle 53 GMT 12/ 3/2021 11: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 36 15.00 505 273 0.27 / 298.38 6 19
2 7 2009.40 40 14.74 3340 1969 2.24 / 300.35 19 67
3 13 1922.64 20 14.70 3216 946 3.19 / 301.30 5 71
4 13 1386.92 20 14.71 2444 719 3.91 / 302.02 5 83
5 13 858.84 20 14.79 1653 489 4.40 / 302.51 5 91
6 13 51.60 20 15.05 414 125 4.52 / 302.63 5 79
7 8 -0.08 263 15.00 338 1333 5.85 / 303.96 5 141
Average= 5.63
(KJ/cycle)

Cycle 52 GMT 2/ 3/2021 13:54: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 36 15.01 488 264 0.26 / 292.55 6 20
2 7 2006.56 41 14.74 3326 2010 2.27 / 294.56 20 67
3 13 1915.72 20 14.71 3207 943 3.22 / 295.50 5 72
4 13 1385.92 20 14.71 2440 718 3.94 / 296.22 5 84
5 13 759.56 20 14.83 1511 448 4.38 / 296.67 5 90
6 13 51.28 20 15.05 420 126 4.51 / 296.79 5 77
7 8 0.12 261 15.00 336 1315 5.83 / 298.11 5 130
Average= 5.62
(KJ/cycle)

Cycle 51 GMT 20/ 2/2021 16:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 36 15.01 511 276 0.28 / 286.61 6 20
2 7 2014.32 40 14.74 3341 1970 2.25 / 288.58 20 65
3 13 1923.52 20 14.71 3225 949 3.19 / 289.53 5 71
4 13 1503.60 20 14.69 2619 769 3.96 / 290.30 5 81
5 13 935.56 20 14.78 1775 525 4.49 / 290.82 5 89
6 13 79.92 20 15.05 469 141 4.63 / 290.96 5 80
7 8 0.08 264 15.01 334 1324 5.95 / 292.29 5 133
Average= 5.62
(KJ/cycle)

Cycle 50 GMT 10/ 2/2021 19:45: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 36 15.02 501 271 0.27 / 280.65 6 19
2 7 2016.16 40 14.75 3337 1969 2.24 / 282.62 19 67
3 13 1929.04 20 14.71 3238 953 3.19 / 283.57 5 72
4 13 1508.40 20 14.70 2630 773 3.97 / 284.35 5 81
5 13 862.48 20 14.82 1663 493 4.46 / 284.84 5 91
6 13 100.24 20 15.05 499 150 4.61 / 284.99 5 80
7 13 20.92 20 15.06 377 114 4.72 / 285.10 5 78
8 8 0.12 240 15.01 341 1228 5.95 / 286.33 5 129
Average= 5.61
(KJ/cycle)

Cycle 49 GMT 31/ 1/2021 22:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.76 35 15.02 493 259 0.26 / 274.79 6 20
2 7 2003.36 40 14.75 3328 1964 2.22 / 276.75 20 66
3 13 1908.40 20 14.72 3217 947 3.17 / 277.70 5 71
4 13 1296.96 20 14.74 2316 683 3.85 / 278.38 5 84
5 13 887.36 20 14.81 1701 504 4.36 / 278.89 5 90
6 13 111.76 20 15.05 516 155 4.51 / 279.04 5 79
7 8 0.00 265 15.02 336 1337 5.85 / 280.38 6 134
Average= 5.61
(KJ/cycle)

Cycle 48 GMT 22/ 1/2021 1:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.64 35 15.03 502 264 0.26 / 268.90 6 23
2 7 2009.16 40 14.75 3342 1972 2.24 / 270.87 23 67
3 13 1918.68 20 14.72 3224 949 3.19 / 271.82 5 72
4 13 1400.68 20 14.73 2468 727 3.91 / 272.54 5 82
5 13 864.60 20 14.82 1669 495 4.41 / 273.04 5 91
6 13 54.96 20 15.08 427 129 4.54 / 273.17 5 76
7 13 14.20 20 15.08 368 111 4.65 / 273.28 5 75
8 8 0.20 242 15.02 345 1254 5.90 / 274.53 6 130
Average= 5.60
(KJ/cycle)

Cycle 47 GMT 12/ 1/2021 4:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.84 35 15.04 502 264 0.26 / 263.03 6 22
2 7 2004.92 41 14.75 3329 2013 2.28 / 265.04 22 67
3 13 1913.88 20 14.71 3217 946 3.22 / 265.99 5 72
4 13 1381.76 20 14.74 2437 718 3.94 / 266.71 5 83
5 13 846.40 20 14.83 1633 484 4.43 / 267.19 5 91
6 13 45.80 20 15.09 404 122 4.55 / 267.31 5 77
7 8 0.16 261 15.04 336 1319 5.87 / 268.63 5 135
Average= 5.60
(KJ/cycle)

Cycle 46 GMT 2/ 1/2021 7:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.60 35 15.04 501 264 0.26 / 257.14 6 24
2 7 2010.04 40 14.75 3328 1964 2.23 / 259.10 5 67
3 13 1919.32 20 14.71 3228 950 3.18 / 260.05 5 71
4 13 1497.84 20 14.72 2623 772 3.95 / 260.82 5 80
5 13 844.24 20 14.84 1643 488 4.44 / 261.31 5 90
6 13 92.00 20 15.08 483 146 4.58 / 261.46 5 78
7 8 0.20 261 15.05 333 1308 5.89 / 262.76 5 133
Average= 5.59
(KJ/cycle)

Cycle 45 GMT 23/12/2020 10:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 35 15.04 509 268 0.27 / 251.20 6 25
2 7 2011.60 41 14.75 3333 2016 2.28 / 253.22 25 67
3 13 1918.12 20 14.73 3204 944 3.23 / 254.16 5 72
4 13 1494.08 20 14.72 2610 768 4.00 / 254.93 5 81
5 13 838.92 20 14.85 1621 481 4.48 / 255.41 5 91
6 13 94.44 20 15.08 488 147 4.62 / 255.56 5 78
7 8 0.00 264 15.05 331 1315 5.94 / 256.87 5 134
Average= 5.58
(KJ/cycle)

Cycle 44 GMT 13/12/2020 13:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.88 35 15.05 510 269 0.27 / 245.21 6 28
2 7 2007.64 40 14.76 3335 1969 2.24 / 247.18 28 67
3 13 1923.36 20 14.72 3227 950 3.19 / 248.13 5 72
4 13 1484.80 20 14.73 2606 768 3.96 / 248.89 5 82
5 13 945.00 20 14.83 1790 531 4.49 / 249.42 5 91
6 13 162.28 20 15.06 602 181 4.67 / 249.61 5 81
7 8 0.16 261 15.05 338 1328 6.00 / 250.93 5 131
Average= 5.58
(KJ/cycle)

Cycle 43 GMT 3/12/2020 16: 9: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 35 15.05 509 268 0.27 / 239.28 6 29
2 7 2004.60 40 14.77 3321 1962 2.23 / 241.24 29 66
3 13 1913.76 20 14.73 3231 952 3.18 / 242.19 5 72
4 13 1490.76 20 14.73 2606 768 3.95 / 242.96 5 81
5 13 926.40 20 14.84 1755 521 4.47 / 243.48 5 91
6 13 77.48 20 15.10 455 137 4.61 / 243.62 5 78
7 8 0.04 259 15.06 339 1322 5.93 / 244.94 5 133
Average= 5.57
(KJ/cycle)

Cycle 42 GMT 23/11/2020 19: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 35 15.05 516 272 0.27 / 233.42 6 33
2 7 2010.64 40 14.76 3354 1980 2.25 / 235.40 33 69
3 13 1914.96 20 14.72 3232 952 3.20 / 236.35 5 73
4 13 1375.00 20 14.76 2441 721 3.92 / 237.08 5 84
5 13 839.04 20 14.87 1638 487 4.41 / 237.56 5 93
6 13 97.60 20 15.09 493 149 4.56 / 237.71 5 80
7 8 0.12 257 15.06 335 1297 5.86 / 239.01 5 129
Average= 5.56
(KJ/cycle)

Cycle 41 GMT 13/11/2020 21:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 35 15.06 513 270 0.27 / 227.57 6 32
2 7 2006.08 40 14.78 3319 1962 2.23 / 229.54 32 67
3 13 1914.96 20 14.73 3212 946 3.18 / 230.48 5 71
4 13 1482.04 20 14.75 2584 762 3.94 / 231.24 5 81
5 13 820.20 20 14.88 1593 474 4.42 / 231.72 5 92
6 13 42.84 20 15.12 406 123 4.54 / 231.84 5 78
7 8 0.12 255 15.07 341 1310 5.85 / 233.15 5 134
Average= 5.55
(KJ/cycle)

Cycle 40 GMT 4/11/2020 0:48: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 35 15.06 505 266 0.27 / 221.68 6 33
2 7 2011.68 40 14.77 3327 1966 2.23 / 223.64 33 66
3 13 1914.60 20 14.74 3215 948 3.18 / 224.59 5 72
4 13 1489.04 20 14.75 2608 769 3.95 / 225.36 5 81
5 13 835.48 20 14.89 1617 482 4.43 / 225.84 5 91
6 13 84.44 20 15.11 470 142 4.57 / 225.98 5 79
7 8 0.12 261 15.07 336 1322 5.89 / 227.30 5 135
Average= 5.54
(KJ/cycle)

Cycle 39 GMT 25/10/2020 3:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.40 35 15.06 507 267 0.27 / 215.78 6 38
2 7 2006.24 40 14.77 3340 1973 2.24 / 217.76 38 67
3 13 1916.20 20 14.74 3227 951 3.19 / 218.71 5 72
4 13 1485.36 20 14.76 2599 767 3.96 / 219.47 5 82
5 13 828.36 20 14.89 1609 479 4.44 / 219.95 5 92
6 13 83.92 20 15.12 474 143 4.58 / 220.10 5 80
7 8 0.08 259 15.08 336 1312 5.89 / 221.41 5 136
Average= 5.54
(KJ/cycle)

Cycle 38 GMT 15/10/2020 6:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.08 35 15.06 524 276 0.28 / 209.83 6 36
2 7 2010.16 40 14.78 3341 1975 2.25 / 211.81 36 67
3 13 1914.12 20 14.75 3199 944 3.20 / 212.75 5 73
4 13 1483.20 20 14.76 2596 766 3.96 / 213.52 5 81
5 13 924.80 20 14.87 1750 520 4.48 / 214.04 5 92
6 13 76.04 20 15.12 460 139 4.62 / 214.18 5 80
7 8 0.04 259 15.08 343 1340 5.96 / 215.52 5 131
Average= 5.53
(KJ/cycle)

Cycle 37 GMT 5/10/2020 9:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.92 35 15.07 519 274 0.27 / 203.91 6 36
2 7 2006.76 40 14.78 3326 1966 2.24 / 205.88 36 67
3 13 1911.88 20 14.75 3216 949 3.19 / 206.83 5 72
4 13 1480.04 20 14.77 2587 764 3.95 / 207.59 5 82
5 13 814.36 20 14.90 1592 474 4.43 / 208.07 5 92
6 13 158.64 20 15.10 594 179 4.61 / 208.25 5 81
7 8 0.04 259 15.09 335 1309 5.92 / 209.55 5 132
Average= 5.51
(KJ/cycle)

Cycle 36 GMT 25/ 9/2020 12:42: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 35 15.08 522 276 0.28 / 198.07 6 34
2 7 2008.60 40 14.78 3333 1970 2.25 / 200.04 34 68
3 13 1915.52 20 14.75 3207 946 3.19 / 200.98 5 72
4 13 1290.48 20 14.80 2321 687 3.88 / 201.67 5 85
5 13 866.16 20 14.89 1670 497 4.38 / 202.17 5 91
6 13 99.04 20 15.12 501 152 4.53 / 202.32 5 79
7 8 0.20 257 15.09 340 1319 5.85 / 203.64 5 134
Average= 5.50
(KJ/cycle)

Cycle 35 GMT 15/ 9/2020 15:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 35 15.09 505 267 0.27 / 192.18 6 31
2 7 2004.48 40 14.79 3323 1966 2.23 / 194.15 31 68
3 13 1908.52 20 14.76 3202 945 3.18 / 195.10 5 72
4 13 1389.56 20 14.79 2458 727 3.90 / 195.82 5 84
5 13 851.12 20 14.90 1658 494 4.40 / 196.32 5 92
6 13 95.08 20 15.13 496 150 4.55 / 196.47 5 79
7 8 0.08 259 15.09 339 1325 5.87 / 197.79 5 138
Average= 5.49
(KJ/cycle)

Cycle 34 GMT 5/ 9/2020 18:38: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 35 15.09 509 269 0.27 / 186.36 6 33
2 7 2011.52 40 14.79 3337 1974 2.24 / 188.33 33 68
3 13 1818.08 20 14.77 3079 910 3.15 / 189.24 5 75
4 13 1389.32 20 14.79 2459 727 3.88 / 189.97 5 84
5 13 850.08 20 14.90 1653 493 4.37 / 190.46 5 92
6 13 81.36 20 15.14 470 142 4.51 / 190.61 5 77
7 8 -0.04 257 15.10 338 1312 5.83 / 191.92 5 129
Average= 5.48
(KJ/cycle)

Cycle 33 GMT 26/ 8/2020 21:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.36 35 15.10 513 271 0.27 / 180.42 6 33
2 7 2004.88 40 14.80 3311 1960 2.23 / 182.38 33 68
3 13 1912.80 20 14.76 3212 948 3.18 / 183.33 5 72
4 13 1481.28 20 14.78 2592 766 3.95 / 184.09 5 81
5 13 930.00 20 14.89 1767 526 4.47 / 184.62 5 91
6 13 138.88 20 15.12 563 170 4.64 / 184.79 5 79
7 8 0.20 259 15.10 333 1302 5.94 / 186.09 5 129
Average= 5.47
(KJ/cycle)

Cycle 32 GMT 17/ 8/2020 0:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.28 35 15.10 520 275 0.27 / 174.57 6 34
2 7 2006.52 40 14.80 3324 1968 2.24 / 176.54 34 67
3 13 1917.48 20 14.77 3217 950 3.19 / 177.49 5 73
4 13 1391.48 20 14.81 2453 727 3.92 / 178.21 5 83
5 13 853.20 20 14.92 1647 491 4.41 / 178.71 5 91
6 13 47.84 20 15.16 409 124 4.53 / 178.83 5 75
7 8 -0.04 261 15.11 334 1317 5.85 / 180.15 5 131
Average= 5.46
(KJ/cycle)

Cycle 31 GMT 7/ 8/2020 3:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 35 15.11 525 278 0.28 / 168.62 6 35
2 7 2006.72 41 14.80 3316 2012 2.29 / 170.63 6 67
3 13 1911.80 20 14.77 3220 951 3.24 / 171.58 5 72
4 13 1483.56 20 14.79 2583 764 4.01 / 172.34 5 82
5 13 823.40 20 14.93 1602 478 4.48 / 172.82 5 93
6 13 38.84 20 15.17 400 121 4.60 / 172.94 5 75
7 8 0.16 261 15.11 343 1353 5.96 / 174.29 5 133
Average= 5.45
(KJ/cycle)

Cycle 30 GMT 28/ 7/2020 6:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.04 35 15.11 502 265 0.27 / 162.77 6 34
2 7 2012.36 40 14.80 3346 1981 2.25 / 164.76 34 68
3 13 1922.96 20 14.77 3214 949 3.20 / 165.70 5 73
4 13 1494.08 20 14.79 2614 773 3.97 / 166.48 5 83
5 13 835.92 20 14.93 1630 487 4.46 / 166.96 5 93
6 13 43.84 20 15.17 414 126 4.58 / 167.09 5 77
7 8 -0.04 244 15.12 338 1247 5.83 / 168.34 5 135
Average= 5.43
(KJ/cycle)

Cycle 29 GMT 18/ 7/2020 9:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 35 15.12 510 270 0.27 / 156.95 6 32
2 7 2009.40 40 14.81 3324 1969 2.24 / 158.91 32 67
3 13 1915.76 20 14.78 3216 951 3.19 / 159.87 5 72
4 13 1283.36 20 14.85 2297 682 3.87 / 160.55 5 85
5 13 848.36 20 14.93 1649 492 4.36 / 161.04 5 93
6 13 86.00 20 15.16 480 146 4.51 / 161.19 5 80
7 8 0.08 259 15.12 338 1324 5.83 / 162.51 5 139
Average= 5.42
(KJ/cycle)

Cycle 28 GMT 8/ 7/2020 12:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 35 15.12 518 274 0.27 / 151.04 6 32
2 7 2007.00 41 14.80 3327 2019 2.29 / 153.06 32 69
3 13 1915.72 20 14.78 3222 952 3.25 / 154.01 5 73
4 13 1482.80 20 14.80 2589 766 4.01 / 154.78 5 82
5 13 821.00 20 14.94 1596 477 4.49 / 155.25 5 92
6 13 73.84 20 15.17 443 134 4.62 / 155.39 5 78
7 8 0.20 257 15.13 331 1287 5.91 / 156.68 5 130
Average= 5.40
(KJ/cycle)

Cycle 27 GMT 28/ 6/2020 15:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 35 15.13 501 265 0.27 / 145.13 6 30
2 7 2014.84 40 14.80 3351 1984 2.25 / 147.11 30 71
3 13 1923.64 20 14.77 3245 959 3.21 / 148.07 5 75
4 13 1379.52 20 14.83 2448 726 3.93 / 148.80 5 86
5 13 826.04 20 14.95 1614 483 4.42 / 149.28 5 95
6 13 76.84 20 15.17 466 141 4.56 / 149.42 5 79
7 8 0.04 261 15.13 341 1347 5.90 / 150.77 6 134
Average= 5.38
(KJ/cycle)

Cycle 26 GMT 18/ 6/2020 18:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 35 15.13 501 265 0.27 / 139.20 6 29
2 7 2007.16 40 14.81 3343 1980 2.25 / 141.18 29 71
3 13 1914.96 20 14.79 3220 952 3.20 / 142.13 5 75
4 13 1374.56 20 14.84 2436 723 3.92 / 142.86 5 87
5 13 821.36 20 14.95 1610 481 4.40 / 143.34 5 96
6 13 248.48 20 15.12 740 224 4.63 / 143.56 5 87
7 8 0.00 259 15.13 332 1301 5.93 / 144.86 5 130
Average= 5.37
(KJ/cycle)

Cycle 25 GMT 8/ 6/2020 21:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.68 35 15.13 511 271 0.27 / 133.28 6 32
2 7 2006.60 41 14.81 3328 2021 2.29 / 135.30 9 71
3 13 1910.84 20 14.79 3200 947 3.24 / 136.25 5 75
4 13 1365.24 20 14.85 2398 712 3.95 / 136.96 5 87
5 13 819.48 20 14.96 1607 481 4.43 / 137.44 5 95
6 13 73.88 20 15.18 465 141 4.57 / 137.59 5 81
7 8 0.24 259 15.14 344 1349 5.92 / 138.93 5 129
Average= 5.34
(KJ/cycle)

Cycle 24 GMT 30/ 5/2020 0:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.48 35 15.13 499 264 0.26 / 127.44 6 33
2 7 2004.16 41 14.82 3330 2023 2.29 / 129.46 33 72
3 13 1906.12 20 14.79 3199 946 3.23 / 130.41 5 75
4 13 1376.48 20 14.84 2435 723 3.96 / 131.13 5 87
5 13 736.16 20 14.99 1466 440 4.40 / 131.57 5 95
6 13 83.08 20 15.18 478 145 4.54 / 131.71 5 82
7 8 -0.04 255 15.15 336 1298 5.84 / 133.01 5 130
Average= 5.32
(KJ/cycle)

Cycle 23 GMT 20/ 5/2020 3:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.68 35 15.15 499 265 0.26 / 121.60 6 31
2 7 2010.28 40 14.83 3349 1987 2.25 / 123.59 31 71
3 13 1919.68 20 14.79 3222 953 3.20 / 124.54 5 75
4 13 1282.72 20 14.88 2297 684 3.89 / 125.23 5 89
5 13 859.72 20 14.96 1651 494 4.38 / 125.72 5 95
6 13 89.36 20 15.18 482 146 4.53 / 125.87 5 84
7 8 0.16 257 15.15 336 1308 5.84 / 127.17 5 132
Average= 5.30
(KJ/cycle)

Cycle 22 GMT 10/ 5/2020 6: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.40 35 15.15 497 264 0.26 / 115.69 6 31
2 7 2004.88 40 14.83 3335 1978 2.24 / 117.67 31 72
3 13 1917.16 20 14.81 3209 951 3.19 / 118.62 5 75
4 13 1482.96 20 14.83 2590 768 3.96 / 119.38 5 85
5 13 910.04 20 14.94 1741 520 4.48 / 119.90 5 95
6 13 58.56 20 15.19 434 132 4.61 / 120.04 5 83
7 8 0.20 257 15.15 334 1300 5.91 / 121.34 5 134
Average= 5.28
(KJ/cycle)

Cycle 21 GMT 30/ 4/2020 9:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.64 35 15.15 503 267 0.27 / 109.86 6 30
2 7 2007.60 41 14.83 3327 2023 2.29 / 111.88 30 72
3 13 1920.72 20 14.82 3203 949 3.24 / 112.83 5 75
4 13 1282.88 20 14.88 2292 682 3.92 / 113.51 5 89
5 13 855.76 20 14.96 1652 494 4.42 / 114.01 5 96
6 13 47.12 20 15.20 412 125 4.54 / 114.13 5 82
7 8 -0.08 257 15.16 332 1294 5.83 / 115.42 6 134
Average= 5.25
(KJ/cycle)

Cycle 20 GMT 20/ 4/2020 12: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 35 15.15 511 271 0.27 / 103.95 6 30
2 7 2014.24 40 14.84 3350 1989 2.26 / 105.94 30 72
3 13 1917.84 20 14.81 3228 956 3.22 / 106.90 5 75
4 13 1475.12 20 14.85 2576 765 3.98 / 107.66 5 86
5 13 812.96 20 14.98 1593 477 4.46 / 108.14 5 96
6 13 139.32 20 15.17 562 171 4.63 / 108.31 5 86
7 8 0.28 257 15.16 328 1278 5.91 / 109.59 5 134
Average= 5.22
(KJ/cycle)

Cycle 19 GMT 10/ 4/2020 15: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.56 34 15.16 508 262 0.26 / 98.06 6 28
2 7 2013.16 40 14.84 3347 1987 2.25 / 100.05 7 72
3 13 1825.44 20 14.84 3086 916 3.16 / 100.96 5 78
4 13 1511.16 20 14.84 2632 781 3.95 / 101.75 5 86
5 13 839.20 20 14.97 1633 489 4.43 / 102.23 5 96
6 13 78.48 20 15.20 468 142 4.58 / 102.38 5 83
7 8 0.00 255 15.16 338 1307 5.88 / 103.68 5 130
Average= 5.18
(KJ/cycle)

Cycle 18 GMT 31/ 3/2020 17:55: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 34 15.16 501 258 0.26 / 92.22 6 29
2 7 2006.12 40 14.85 3332 1979 2.24 / 94.20 29 72
3 13 1910.28 20 14.82 3230 957 3.19 / 95.15 5 76
4 13 1364.92 20 14.88 2403 715 3.91 / 95.87 5 88
5 13 819.72 20 14.99 1616 484 4.39 / 96.35 5 96
6 13 67.36 20 15.21 452 137 4.53 / 96.49 5 83
7 8 0.04 257 15.17 336 1310 5.84 / 97.80 5 135
Average= 5.15
(KJ/cycle)

Cycle 17 GMT 21/ 3/2020 20:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 34 15.17 510 263 0.26 / 86.33 6 26
2 7 2008.36 40 14.85 3336 1982 2.24 / 88.32 26 70
3 13 1920.84 20 14.83 3208 951 3.20 / 89.27 5 76
4 13 1485.24 20 14.86 2577 766 3.96 / 90.03 5 85
5 13 821.96 20 14.99 1612 483 4.45 / 90.52 5 96
6 13 43.36 20 15.22 413 126 4.57 / 90.64 5 80
7 8 -0.08 255 15.17 340 1315 5.89 / 91.96 5 129
Average= 5.11
(KJ/cycle)

Cycle 16 GMT 11/ 3/2020 23:57: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 34 15.17 503 259 0.26 / 80.40 6 27
2 7 2012.76 40 14.85 3346 1988 2.25 / 82.38 27 71
3 13 1916.48 20 14.82 3230 957 3.20 / 83.34 5 75
4 13 1475.24 20 14.86 2586 769 3.97 / 84.11 5 85
5 13 914.28 20 14.97 1748 523 4.50 / 84.63 5 95
6 13 56.88 20 15.22 428 130 4.63 / 84.76 5 82
7 8 0.04 259 15.18 333 1309 5.94 / 86.07 5 138
Average= 5.06
(KJ/cycle)

Cycle 15 GMT 2/ 3/2020 2:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.80 34 15.18 487 251 0.25 / 74.62 6 24
2 7 2005.56 40 14.85 3342 1985 2.24 / 76.61 24 72
3 13 1910.20 20 14.84 3207 952 3.19 / 77.56 5 75
4 13 1373.20 20 14.90 2433 725 3.91 / 78.28 5 88
5 13 712.88 20 15.03 1444 434 4.35 / 78.72 5 96
6 13 38.44 20 15.23 400 122 4.47 / 78.84 5 81
7 8 0.20 255 15.18 335 1297 5.77 / 80.14 5 129
Average= 5.01
(KJ/cycle)

Cycle 14 GMT 21/ 2/2020 5:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.08 34 15.18 491 253 0.25 / 68.77 6 26
2 7 2005.20 40 14.87 3344 1989 2.24 / 70.76 26 71
3 13 1908.56 20 14.85 3195 949 3.19 / 71.71 5 76
4 13 1363.08 20 14.90 2412 719 3.91 / 72.43 5 88
5 13 811.92 20 15.01 1598 480 4.39 / 72.91 5 96
6 13 68.64 20 15.22 458 139 4.53 / 73.05 5 81
7 8 0.00 259 15.18 336 1321 5.85 / 74.37 5 139
Average= 4.96
(KJ/cycle)

Cycle 13 GMT 11/ 2/2020 8:49: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.48 34 15.19 504 260 0.26 / 63.10 6 26
2 7 2012.28 40 14.86 3351 1992 2.25 / 65.10 26 71
3 13 1818.48 20 14.85 3092 918 3.17 / 66.01 5 77
4 13 1265.60 20 14.92 2272 678 3.85 / 66.69 5 90
5 13 639.08 20 15.06 1329 400 4.25 / 67.09 5 95
6 13 44.56 20 15.23 412 125 4.37 / 67.22 5 80
7 8 0.04 255 15.19 336 1301 5.68 / 68.52 5 135
Average= 4.89
(KJ/cycle)

Cycle 12 GMT 1/ 2/2020 11:37: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 34 15.19 505 261 0.26 / 57.28 6 27
2 7 2013.88 40 14.87 3366 2002 2.26 / 59.28 27 71
3 13 1917.84 20 14.86 3232 961 3.22 / 60.24 5 77
4 13 1296.84 20 14.92 2319 692 3.92 / 60.93 5 89
5 13 776.00 20 15.02 1541 463 4.38 / 61.40 5 96
6 13 51.08 20 15.24 433 132 4.51 / 61.53 5 81
7 8 0.04 257 15.19 337 1316 5.83 / 62.84 5 130
Average= 4.83
(KJ/cycle)

Cycle 11 GMT 22/ 1/2020 14:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.24 34 15.19 501 259 0.26 / 51.43 6 26
2 7 2005.64 40 14.87 3340 1987 2.25 / 53.42 26 73
3 13 1908.52 20 14.86 3203 952 3.20 / 54.37 5 77
4 13 1572.60 20 14.87 2721 809 4.01 / 55.18 5 85
5 13 678.96 20 15.06 1383 417 4.42 / 55.59 5 95
6 13 61.52 20 15.24 445 136 4.56 / 55.73 5 80
7 8 0.24 253 15.20 335 1288 5.85 / 57.02 5 129
Average= 4.75
(KJ/cycle)

Cycle 10 GMT 12/ 1/2020 17:29: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 34 15.21 500 259 0.26 / 45.58 6 27
2 7 2003.44 40 14.88 3340 1988 2.25 / 47.57 10 73
3 13 1905.36 20 14.86 3228 959 3.21 / 48.53 5 77
4 13 1285.56 20 14.93 2308 689 3.90 / 49.22 5 90
5 13 852.60 20 15.01 1658 498 4.39 / 49.72 5 96
6 13 38.12 20 15.25 409 125 4.52 / 49.84 5 80
7 8 0.04 259 15.20 338 1331 5.85 / 51.17 5 137
Average= 4.65
(KJ/cycle)

Cycle 9 GMT 2/ 1/2020 20:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 34 15.22 451 233 0.23 / 40.14 6 33
2 7 2004.52 40 14.90 3279 1954 2.19 / 42.09 33 73
3 13 1912.88 20 14.88 3169 943 3.13 / 43.03 5 77
4 13 1284.08 20 14.95 2250 673 3.80 / 43.71 5 91
5 13 757.88 20 15.05 1461 440 4.24 / 44.15 5 98
6 13 42.64 20 15.26 354 108 4.35 / 44.26 5 81
7 8 0.04 255 15.23 275 1068 5.42 / 45.32 5 136
Average= 4.53
(KJ/cycle)

Cycle 8 GMT 23/12/2019 23:18: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 34 15.22 448 232 0.23 / 34.60 6 32
2 7 2019.64 40 14.90 3303 1969 2.20 / 36.57 32 74
3 13 1927.96 20 14.88 3183 947 3.15 / 37.51 5 77
4 13 1352.96 20 14.94 2347 701 3.85 / 38.22 5 90
5 13 906.80 20 15.01 1683 505 4.35 / 38.72 5 98
6 13 23.52 20 15.27 326 100 4.45 / 38.82 5 83
7 8 0.04 253 15.23 281 1083 5.54 / 39.90 5 136
Average= 4.43
(KJ/cycle)

Cycle 7 GMT 14/12/2019 2:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.96 33 15.22 442 222 0.22 / 29.15 6 36
2 7 2005.84 40 14.91 3280 1956 2.18 / 31.11 36 73
3 13 1909.44 20 14.89 3159 941 3.12 / 32.05 5 78
4 13 1360.04 20 14.95 2362 706 3.83 / 32.76 5 89
5 13 720.12 20 15.07 1399 422 4.25 / 33.18 5 98
6 13 41.84 20 15.27 357 109 4.36 / 33.29 5 81
7 8 0.04 253 15.23 280 1079 5.43 / 34.37 5 132
Average= 4.30
(KJ/cycle)

Cycle 6 GMT 4/12/2019 5:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.32 33 15.23 448 225 0.23 / 23.62 6 37
2 3 1036.24 1 15.25 1910 29 0.25 / 23.65 5 55
3 7 2011.60 40 14.91 3280 1956 2.21 / 25.60 55 72
4 13 1814.32 20 14.91 3025 902 3.11 / 26.51 5 79
5 13 1388.88 20 14.94 2407 719 3.83 / 27.23 5 89
6 13 942.84 20 15.01 1741 523 4.35 / 27.75 5 96
7 13 67.76 20 15.26 398 121 4.48 / 27.87 5 82
8 8 0.28 251 15.23 278 1063 5.54 / 28.93 5 132
Average= 4.13
(KJ/cycle)

Cycle 5 GMT 24/11/2019 8:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.40 31 15.24 453 214 0.21 / 18.13 6 37
2 3 1069.20 2 15.24 1958 60 0.27 / 18.19 5 74
3 7 2006.44 40 14.92 3286 1961 2.23 / 20.15 74 73
4 13 1917.08 20 14.90 3176 946 3.18 / 21.10 5 77
5 13 1368.28 20 14.95 2372 709 3.89 / 21.81 5 89
6 13 812.40 20 15.05 1550 467 4.36 / 22.27 5 98
7 8 -0.04 263 15.24 280 1122 5.48 / 23.39 5 129
Average= 3.90
(KJ/cycle)

Cycle 4 GMT 14/11/2019 11:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.00 32 15.24 448 218 0.22 / 13.58 6 37
2 7 1513.00 40 15.08 2552 1539 1.76 / 15.12 37 79
3 13 1436.80 20 15.05 2459 740 2.50 / 15.86 5 84
4 13 1134.04 20 15.06 2018 608 3.11 / 16.47 5 91
5 13 482.76 20 15.18 1048 318 3.42 / 16.79 5 97
6 8 0.20 263 15.26 281 1128 4.55 / 17.91 5 132
Average= 3.58
(KJ/cycle)

Cycle 3 GMT 13/11/2019 1:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.28 32 15.23 446 217 0.22 / 8.92 5 36
2 7 1518.64 40 15.07 2553 1539 1.76 / 10.46 34 77
3 13 1451.56 20 15.05 2478 746 2.50 / 11.20 5 83
4 13 1256.04 20 15.03 2191 659 3.16 / 11.86 5 89
5 13 585.48 20 15.16 1183 359 3.52 / 12.22 5 95
6 13 24.20 20 15.30 321 98 3.62 / 12.32 5 84
7 8 0.12 244 15.26 280 1043 4.66 / 13.36 5 134
Average= 3.34
(KJ/cycle)

Cycle 2 GMT 11/11/2019 15: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 31 15.27 443 210 0.21 / 4.39 6 38
2 3 1041.28 1 15.27 1893 29 0.24 / 4.41 5 72
3 7 1517.68 41 15.06 2551 1575 1.81 / 5.99 72 77
4 13 1450.08 20 15.05 2468 743 2.56 / 6.73 5 83
5 13 1054.24 20 15.06 1899 572 3.13 / 7.30 5 93
6 13 418.12 20 15.19 944 287 3.42 / 7.59 5 95
7 8 -0.04 264 15.25 276 1111 4.53 / 8.70 5 129
Average= 2.90
(KJ/cycle)

Cycle 1 GMT 10/11/2019 4:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.12 31 15.41 431 206 0.21 / 1.76 6 29
2 3 1027.96 1 15.27 1908 29 0.24 / 1.78 5 68
3 7 1007.88 40 15.16 1803 1093 1.33 / 2.88 68 84
4 13 256.44 20 15.30 692 212 1.54 / 3.09 5 86
5 8 0.08 257 15.31 276 1086 2.63 / 4.18 5 131
Average= 2.09
(KJ/cycle)

Cycle 0 GMT 9/11/2019 18: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 30 15.56 437 204 0.20 / 0.20 6 45
2 7 116.56 40 15.54 446 277 0.48 / 0.48 45 48
3 13 30.32 20 15.54 311 97 0.58 / 0.58 6 50
4 8 0.16 250 15.49 251 972 1.55 / 1.55 6 132
Average= 1.55
(KJ/cycle)