SIO Argo Site:
Pump Diagnostics Page   



Serial= 8733 WMO= 1902046

Return

←PreviousNext→

Cycle 192 GMT 24/ 3/2024 1:25: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.72 35 15.00 480 252 0.25 / 755.78 2 2
2 7 2011.12 33 14.90 2895 1423 1.68 / 757.21 2 2
3 13 1684.64 18 14.88 2526 677 2.35 / 757.88 2 3
4 13 1014.88 18 14.91 1708 458 2.81 / 758.34 2 3
5 13 508.00 18 14.98 1034 279 3.09 / 758.62 2 3
6 8 0.36 165 15.04 328 814 3.90 / 759.43 2 8
Average= 3.93
(KJ/cycle)

Cycle 191 GMT 14/ 3/2024 3:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.04 35 14.99 486 255 0.25 / 751.78 2 2
2 7 2004.72 34 14.91 2880 1460 1.71 / 753.24 2 2
3 13 1540.00 18 14.89 2360 633 2.35 / 753.87 2 2
4 13 1203.40 18 14.88 1944 521 2.87 / 754.39 2 3
5 13 357.84 18 15.01 828 224 3.09 / 754.62 2 3
6 13 39.76 18 15.07 392 106 3.20 / 754.72 2 3
7 8 0.00 165 15.04 325 807 4.00 / 755.53 2 12
Average= 3.94
(KJ/cycle)

Cycle 190 GMT 4/ 3/2024 6: 4: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 35 14.99 488 256 0.26 / 747.78 2 2
2 7 2008.40 33 14.91 2890 1422 1.68 / 749.20 2 2
3 13 1539.80 18 14.89 2358 632 2.31 / 749.83 2 2
4 13 1065.56 18 14.90 1763 473 2.78 / 750.30 2 3
5 13 568.40 18 14.96 1111 299 3.08 / 750.60 2 3
6 13 44.56 18 15.06 397 108 3.19 / 750.71 2 3
7 8 0.00 165 15.03 329 816 4.01 / 751.53 2 9
Average= 3.93
(KJ/cycle)

Cycle 189 GMT 23/ 2/2024 8:15: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 35 15.00 479 251 0.25 / 743.77 2 2
2 7 2014.24 33 14.91 2896 1425 1.68 / 745.20 2 2
3 13 1553.08 18 14.89 2373 636 2.31 / 745.83 2 2
4 13 1078.20 18 14.89 1781 477 2.79 / 746.31 2 3
5 13 564.52 18 14.96 1104 297 3.09 / 746.61 2 3
6 13 18.96 18 15.06 362 98 3.19 / 746.71 2 3
7 8 0.04 165 15.03 329 816 4.00 / 747.52 2 10
Average= 3.93
(KJ/cycle)

Cycle 188 GMT 13/ 2/2024 10:30: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.76 35 15.00 481 253 0.25 / 739.83 2 2
2 7 2008.12 33 14.91 2892 1423 1.68 / 741.25 2 2
3 13 1693.92 18 14.88 2535 679 2.35 / 741.93 2 2
4 13 1169.04 18 14.89 1896 508 2.86 / 742.44 2 3
5 13 493.12 18 14.98 1006 271 3.13 / 742.71 2 3
6 8 0.20 165 15.04 327 811 3.95 / 743.52 2 12
Average= 3.93
(KJ/cycle)

Cycle 187 GMT 3/ 2/2024 12:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.52 35 14.99 476 250 0.25 / 735.92 2 2
2 7 2006.80 33 14.92 2884 1420 1.67 / 737.34 2 2
3 13 1679.88 18 14.89 2517 675 2.34 / 738.02 2 2
4 13 1030.80 18 14.91 1721 462 2.81 / 738.48 2 3
5 13 541.88 18 14.97 1069 288 3.09 / 738.77 2 3
6 8 0.24 165 15.05 325 807 3.90 / 739.57 2 7
Average= 3.93
(KJ/cycle)

Cycle 186 GMT 24/ 1/2024 15: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 35 15.00 480 252 0.25 / 732.01 2 2
2 7 2018.28 33 14.91 2900 1427 1.68 / 733.43 2 2
3 13 1569.84 18 14.89 2390 641 2.32 / 734.07 2 3
4 13 1098.12 18 14.89 1809 485 2.80 / 734.56 2 3
5 13 585.60 18 14.96 1137 306 3.11 / 734.86 2 3
6 8 -0.04 165 15.04 326 809 3.92 / 735.67 2 9
Average= 3.93
(KJ/cycle)

Cycle 185 GMT 14/ 1/2024 17:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.72 35 15.01 489 257 0.26 / 727.97 2 2
2 7 2003.40 33 14.92 2861 1409 1.67 / 729.38 2 2
3 13 1680.52 18 14.89 2517 675 2.34 / 730.06 2 3
4 13 1041.24 18 14.91 1729 464 2.80 / 730.52 2 3
5 13 541.12 18 14.98 1070 289 3.09 / 730.81 2 3
6 13 39.00 18 15.07 391 106 3.20 / 730.92 2 2
7 8 -0.04 165 15.04 338 839 4.04 / 731.75 2 8
Average= 3.93
(KJ/cycle)

Cycle 184 GMT 4/ 1/2024 19:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.16 35 15.00 491 258 0.26 / 723.93 2 2
2 7 2003.88 33 14.90 2882 1417 1.67 / 725.35 2 3
3 13 1533.76 18 14.89 2352 630 2.31 / 725.98 2 3
4 13 1201.76 18 14.88 1953 523 2.83 / 726.50 2 3
5 13 520.40 18 14.98 1061 286 3.11 / 726.79 2 3
6 13 33.04 18 15.08 386 105 3.22 / 726.89 2 3
7 8 0.20 165 15.05 331 822 4.04 / 727.72 2 9
Average= 3.93
(KJ/cycle)

Cycle 183 GMT 25/12/2023 21:43: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.16 35 15.00 486 255 0.26 / 719.96 2 2
2 7 2004.04 33 14.91 2882 1418 1.67 / 721.38 2 2
3 13 1679.84 18 14.88 2519 675 2.35 / 722.05 2 3
4 13 1167.20 18 14.88 1903 510 2.86 / 722.56 2 3
5 13 490.92 18 14.98 1013 273 3.13 / 722.84 2 3
6 8 0.12 165 15.04 338 839 3.97 / 723.68 2 7
Average= 3.93
(KJ/cycle)

Cycle 182 GMT 16/12/2023 0: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.64 35 15.00 481 253 0.25 / 716.01 2 2
2 7 2009.96 33 14.91 2880 1417 1.67 / 717.42 2 2
3 13 1695.48 18 14.89 2543 682 2.35 / 718.11 2 3
4 13 1186.96 18 14.89 1921 515 2.87 / 718.62 2 3
5 13 499.80 18 14.99 1022 276 3.14 / 718.90 2 3
6 8 0.12 165 15.05 326 810 3.95 / 719.71 2 8
Average= 3.93
(KJ/cycle)

Cycle 181 GMT 6/12/2023 2:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 35 15.00 470 247 0.25 / 711.85 2 2
2 7 2005.68 33 14.91 2882 1418 1.66 / 713.27 2 2
3 13 1676.96 18 14.89 2512 673 2.34 / 713.94 2 3
4 13 1027.36 18 14.91 1706 458 2.80 / 714.40 2 3
5 13 535.84 18 14.98 1064 287 3.08 / 714.68 2 3
6 13 77.64 18 15.06 442 120 3.20 / 714.80 2 3
7 8 0.12 165 15.04 324 804 4.01 / 715.61 2 7
8 14 0.12 30 15.02 324 146 4.15 / 715.75 2 8
Average= 3.93
(KJ/cycle)

Cycle 180 GMT 26/11/2023 4:34:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.00 35 15.01 468 246 0.25 / 707.75 2 2
2 7 2009.52 33 14.90 2882 1417 1.66 / 709.17 2 2
3 13 1685.80 18 14.88 2529 677 2.34 / 709.85 2 3
4 13 1174.76 18 14.88 1914 513 2.85 / 710.36 2 3
5 13 643.24 18 14.95 1214 327 3.18 / 710.69 2 3
6 13 23.04 18 15.07 368 100 3.28 / 710.79 2 3
7 8 -0.08 165 15.04 328 814 4.09 / 711.60 2 6
Average= 3.93
(KJ/cycle)

Cycle 179 GMT 16/11/2023 7: 7:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 35 15.00 476 250 0.25 / 703.85 2 2
2 7 2014.52 33 14.91 2893 1423 1.67 / 705.28 2 2
3 13 1701.64 18 14.88 2542 681 2.35 / 705.96 2 3
4 13 1038.76 18 14.91 1734 465 2.82 / 706.42 2 3
5 13 537.16 18 14.98 1067 288 3.11 / 706.71 2 3
6 8 0.12 165 15.05 321 797 3.90 / 707.51 2 10
Average= 3.93
(KJ/cycle)

Cycle 178 GMT 6/11/2023 9:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 35 15.00 471 247 0.25 / 700.00 2 2
2 7 1939.48 33 14.91 2817 1386 1.63 / 701.39 2 3
3 13 1616.64 18 14.89 2449 656 2.29 / 702.05 2 3
4 13 1126.60 18 14.90 1843 494 2.78 / 702.54 2 3
5 13 471.44 18 14.99 972 262 3.05 / 702.80 2 2
6 8 0.28 165 15.05 323 802 3.85 / 703.60 2 9
Average= 3.93
(KJ/cycle)

Cycle 177 GMT 27/10/2023 8:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 35 15.00 471 247 0.25 / 696.10 2 2
2 7 2012.52 33 14.91 2896 1425 1.67 / 697.52 2 2
3 13 1693.56 18 14.88 2530 678 2.35 / 698.20 2 2
4 13 1035.40 18 14.91 1721 462 2.81 / 698.66 2 3
5 13 541.00 18 14.98 1065 287 3.10 / 698.95 2 3
6 8 0.24 165 15.05 324 805 3.90 / 699.76 2 8
Average= 3.93
(KJ/cycle)

Cycle 176 GMT 17/10/2023 10:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 35 15.00 470 247 0.25 / 692.03 2 2
2 7 2009.92 33 14.91 2880 1417 1.66 / 693.45 2 2
3 13 1862.12 18 14.86 2728 730 2.39 / 694.17 2 2
4 13 1135.92 18 14.90 1854 497 2.89 / 694.67 2 3
5 13 471.52 18 14.99 973 263 3.15 / 694.93 2 3
6 13 67.36 18 15.07 419 114 3.27 / 695.05 2 2
7 8 0.20 165 15.04 324 804 4.07 / 695.85 2 6
Average= 3.93
(KJ/cycle)

Cycle 175 GMT 7/10/2023 13:17: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.68 35 15.01 483 254 0.25 / 688.08 2 2
2 3 1021.72 1 15.19 1743 26 0.28 / 688.11 2 2
3 7 2003.68 33 14.92 2869 1413 1.69 / 689.52 2 2
4 13 1677.20 18 14.89 2501 670 2.36 / 690.19 2 2
5 13 1175.36 18 14.89 1900 509 2.87 / 690.70 2 3
6 13 506.48 18 14.99 1020 275 3.15 / 690.98 2 3
7 8 0.08 165 15.04 324 804 3.95 / 691.78 2 5
Average= 3.93
(KJ/cycle)

Cycle 174 GMT 27/ 9/2023 15:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.36 35 15.03 474 249 0.25 / 684.27 2 2
2 7 2008.32 33 14.92 2870 1413 1.66 / 685.69 2 2
3 13 1552.72 18 14.90 2354 631 2.29 / 686.32 2 3
4 13 1082.20 18 14.91 1769 475 2.77 / 686.79 2 2
5 13 428.44 18 15.01 903 244 3.01 / 687.04 2 3
6 8 0.24 165 15.06 319 793 3.81 / 687.83 2 7
Average= 3.93
(KJ/cycle)

Cycle 173 GMT 17/ 9/2023 17:50: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.80 35 15.03 477 251 0.25 / 680.33 2 2
2 7 1880.48 33 14.94 2759 1360 1.61 / 681.69 2 2
3 13 1584.52 18 14.92 2417 649 2.26 / 682.34 2 3
4 13 1100.92 18 14.93 1813 487 2.75 / 682.82 2 2
5 13 435.72 18 15.02 924 250 3.00 / 683.07 2 3
6 8 0.28 165 15.07 323 803 3.80 / 683.88 2 8
7 14 0.28 30 15.04 325 147 3.95 / 684.02 2 12
Average= 3.93
(KJ/cycle)

Cycle 172 GMT 7/ 9/2023 17: 6: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.96 35 15.02 485 255 0.25 / 676.25 2 2
2 7 2006.44 33 14.93 2879 1418 1.67 / 677.67 2 2
3 13 1552.92 18 14.91 2369 636 2.31 / 678.30 2 3
4 13 1209.24 18 14.90 1949 523 2.83 / 678.83 2 3
5 13 536.20 18 15.00 1070 289 3.12 / 679.11 2 3
6 8 -0.20 165 15.08 328 816 3.94 / 679.93 2 6
7 14 -0.20 30 15.05 326 147 4.08 / 680.08 2 10
Average= 3.93
(KJ/cycle)

Cycle 171 GMT 28/ 8/2023 19:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.80 34 15.02 486 248 0.25 / 672.32 2 2
2 7 2002.88 33 14.92 2882 1419 1.67 / 673.74 2 3
3 13 1546.08 18 14.91 2368 636 2.30 / 674.38 2 2
4 13 1074.72 18 14.91 1794 481 2.78 / 674.86 2 3
5 13 561.56 18 14.99 1116 301 3.09 / 675.16 2 3
6 8 0.28 165 15.07 336 835 3.92 / 675.99 2 8
Average= 3.93
(KJ/cycle)

Cycle 170 GMT 18/ 8/2023 21:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 34 15.04 490 251 0.25 / 668.27 2 2
2 7 2011.52 33 14.92 2890 1423 1.67 / 669.70 2 2
3 13 1544.60 18 14.91 2360 633 2.31 / 670.33 2 3
4 13 1217.44 18 14.90 1968 528 2.83 / 670.86 2 3
5 13 523.52 18 15.00 1062 287 3.12 / 671.14 2 3
6 13 37.24 18 15.10 393 107 3.23 / 671.25 2 3
7 8 0.00 165 15.06 331 823 4.05 / 672.07 2 10
Average= 3.93
(KJ/cycle)

Cycle 169 GMT 8/ 8/2023 23:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.28 34 15.02 490 250 0.25 / 664.18 2 2
2 7 2005.16 33 14.93 2879 1418 1.67 / 665.59 2 3
3 13 1553.84 18 14.92 2371 637 2.31 / 666.23 2 2
4 13 1217.52 18 14.90 1969 528 2.83 / 666.76 2 3
5 13 510.40 18 15.01 1044 282 3.12 / 667.04 2 3
6 8 -0.12 165 15.08 334 831 3.95 / 667.87 2 8
7 14 -0.12 30 15.06 330 149 4.10 / 668.02 2 10
Average= 3.93
(KJ/cycle)

Cycle 168 GMT 30/ 7/2023 1:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 34 15.05 492 252 0.25 / 659.92 2 2
2 3 1030.24 1 15.16 1786 27 0.28 / 659.95 2 2
3 7 2003.12 33 14.92 2895 1425 1.70 / 661.37 2 2
4 13 1868.40 18 14.88 2752 737 2.44 / 662.11 2 2
5 13 1139.20 18 14.91 1877 504 2.95 / 662.61 2 3
6 13 612.72 18 14.97 1196 322 3.27 / 662.94 2 3
7 13 59.08 18 15.09 439 119 3.39 / 663.06 2 3
8 8 0.12 165 15.06 350 870 4.26 / 663.93 2 10
Average= 3.93
(KJ/cycle)

Cycle 167 GMT 20/ 7/2023 3:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.24 33 15.04 486 241 0.24 / 655.75 2 2
2 3 1029.68 1 15.14 1795 27 0.27 / 655.78 2 2
3 7 2003.52 33 14.93 2887 1422 1.69 / 657.20 2 2
4 13 1671.40 18 14.91 2514 675 2.37 / 657.87 2 3
5 13 1157.84 18 14.92 1892 508 2.87 / 658.38 2 3
6 13 488.60 18 15.02 1027 278 3.15 / 658.66 2 3
7 8 0.16 165 15.08 344 856 4.01 / 659.52 2 8
8 14 0.16 30 15.06 342 155 4.16 / 659.67 2 10
Average= 3.93
(KJ/cycle)

Cycle 166 GMT 10/ 7/2023 6:11: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.92 33 15.03 499 247 0.25 / 651.74 2 2
2 7 2007.44 33 14.92 2907 1431 1.68 / 653.17 2 3
3 13 1681.80 18 14.91 2519 676 2.35 / 653.85 2 3
4 13 1155.04 18 14.92 1896 509 2.86 / 654.35 2 3
5 13 498.88 18 15.02 1043 282 3.15 / 654.64 2 3
6 8 0.16 165 15.09 350 871 4.02 / 655.51 2 9
Average= 3.93
(KJ/cycle)

Cycle 165 GMT 30/ 6/2023 8: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.12 33 15.02 502 249 0.25 / 647.48 2 2
2 7 2004.40 33 14.92 2897 1426 1.68 / 648.91 2 2
3 13 1676.44 18 14.91 2535 680 2.36 / 649.59 2 3
4 13 1129.88 18 14.93 1855 499 2.85 / 650.09 2 3
5 13 464.08 18 15.02 1003 271 3.13 / 650.36 2 3
6 13 15.48 18 15.12 379 103 3.23 / 650.46 2 3
7 8 0.08 165 15.08 350 871 4.10 / 651.33 2 7
8 14 0.08 30 15.05 345 156 4.26 / 651.49 2 11
Average= 3.92
(KJ/cycle)

Cycle 164 GMT 20/ 6/2023 10:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.20 34 15.03 500 256 0.26 / 643.30 2 2
2 7 2009.36 33 14.91 2904 1429 1.68 / 644.73 2 2
3 13 1513.04 18 14.91 2332 626 2.31 / 645.35 2 3
4 13 1185.56 18 14.91 1934 519 2.83 / 645.87 2 3
5 13 637.28 18 14.97 1247 336 3.17 / 646.21 2 3
6 8 -0.12 165 15.08 350 871 4.04 / 647.08 2 11
7 14 -0.12 30 15.05 347 157 4.19 / 647.24 2 14
Average= 3.92
(KJ/cycle)

Cycle 163 GMT 10/ 6/2023 12:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 34 15.03 494 252 0.25 / 639.11 2 2
2 7 2004.04 33 14.92 2907 1431 1.68 / 640.54 2 2
3 13 1853.68 18 14.87 2739 733 2.42 / 641.27 2 3
4 13 1102.80 18 14.92 1823 490 2.91 / 641.76 2 3
5 13 577.92 18 14.99 1168 315 3.22 / 642.08 2 3
6 13 21.44 18 15.11 384 104 3.33 / 642.18 2 3
7 8 0.00 165 15.08 346 861 4.19 / 643.04 2 9
Average= 3.92
(KJ/cycle)

Cycle 162 GMT 31/ 5/2023 14:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 34 15.04 485 248 0.25 / 635.15 2 2
2 7 2009.04 33 14.92 2897 1426 1.67 / 636.57 2 2
3 13 1548.08 18 14.91 2370 636 2.31 / 637.21 2 2
4 13 1060.16 18 14.92 1779 478 2.79 / 637.69 2 3
5 13 563.76 18 14.99 1125 304 3.09 / 637.99 2 3
6 8 0.28 165 15.07 348 865 3.96 / 638.86 2 8
Average= 3.92
(KJ/cycle)

Cycle 161 GMT 21/ 5/2023 16:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 35 15.03 493 259 0.26 / 631.29 2 2
2 7 2003.08 33 14.92 2888 1422 1.68 / 632.71 2 3
3 13 1513.76 18 14.92 2326 625 2.31 / 633.34 2 2
4 13 1039.28 18 14.93 1754 471 2.78 / 633.81 2 3
5 13 392.44 18 15.04 896 243 3.02 / 634.05 2 3
6 8 -0.12 165 15.08 341 848 3.87 / 634.90 2 7
Average= 3.92
(KJ/cycle)

Cycle 160 GMT 11/ 5/2023 18:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 35 15.01 477 251 0.25 / 627.18 2 2
2 7 2004.60 33 14.92 2900 1428 1.68 / 628.61 2 2
3 13 1685.56 18 14.90 2535 680 2.36 / 629.29 2 2
4 13 1026.28 18 14.93 1725 464 2.82 / 629.76 2 3
5 13 520.76 18 15.00 1076 291 3.11 / 630.05 2 3
6 8 0.16 165 15.08 335 834 3.95 / 630.88 2 8
7 14 0.16 30 15.05 333 150 4.10 / 631.03 2 14
Average= 3.92
(KJ/cycle)

Cycle 159 GMT 1/ 5/2023 20:40: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.20 35 15.03 459 241 0.24 / 623.18 2 2
2 7 2007.48 33 14.90 2885 1419 1.66 / 624.60 2 3
3 13 1667.40 18 14.89 2507 672 2.33 / 625.27 2 3
4 13 992.00 18 14.93 1674 450 2.78 / 625.72 2 3
5 13 495.72 18 15.00 1031 278 3.06 / 626.00 2 3
6 13 65.44 18 15.09 430 117 3.18 / 626.12 2 3
7 8 0.04 165 15.06 329 818 3.99 / 626.93 2 10
Average= 3.92
(KJ/cycle)

Cycle 158 GMT 21/ 4/2023 22:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 35 15.03 461 243 0.24 / 619.22 2 2
2 7 2004.80 33 14.92 2880 1418 1.66 / 620.63 2 2
3 13 1557.76 18 14.91 2369 636 2.30 / 621.27 2 2
4 13 1083.32 18 14.92 1790 481 2.78 / 621.75 2 3
5 13 573.00 18 14.98 1114 300 3.08 / 622.05 2 3
6 13 52.76 18 15.09 396 108 3.18 / 622.16 2 2
7 8 0.00 165 15.06 314 780 3.97 / 622.94 2 9
Average= 3.92
(KJ/cycle)

Cycle 157 GMT 12/ 4/2023 0:52: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 35 15.04 461 243 0.24 / 615.09 2 2
2 7 2013.20 34 14.93 2882 1463 1.71 / 616.55 2 2
3 13 1545.88 18 14.91 2359 633 2.34 / 617.18 2 2
4 13 1069.12 18 14.92 1773 476 2.81 / 617.66 2 3
5 13 543.20 18 15.00 1078 291 3.11 / 617.95 2 3
6 13 48.04 18 15.10 389 106 3.21 / 618.06 2 2
7 8 0.00 165 15.08 313 779 3.99 / 618.83 2 7
8 14 0.00 30 15.06 310 140 4.13 / 618.97 3 13
Average= 3.92
(KJ/cycle)

Cycle 156 GMT 2/ 4/2023 3: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.16 35 15.03 454 239 0.24 / 611.18 2 2
2 7 2003.88 33 14.92 2885 1420 1.66 / 612.60 2 2
3 13 1531.48 18 14.91 2335 627 2.29 / 613.23 2 3
4 13 1063.76 18 14.91 1772 476 2.76 / 613.70 2 3
5 13 415.28 18 15.03 909 246 3.01 / 613.95 2 3
6 13 59.72 18 15.10 409 111 3.12 / 614.06 2 2
7 8 0.04 165 15.08 315 784 3.90 / 614.84 2 7
Average= 3.92
(KJ/cycle)

Cycle 155 GMT 23/ 3/2023 5:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.64 35 15.04 437 230 0.23 / 607.10 2 2
2 7 2008.76 33 14.92 2881 1418 1.65 / 608.52 2 2
3 13 1676.96 18 14.90 2518 675 2.32 / 609.20 2 2
4 13 1146.16 18 14.91 1873 503 2.83 / 609.70 2 3
5 13 479.36 18 15.01 984 266 3.09 / 609.96 2 3
6 13 78.04 18 15.09 428 116 3.21 / 610.08 2 2
7 13 18.80 18 15.10 342 93 3.30 / 610.17 2 2
8 8 0.04 165 15.07 309 768 4.07 / 610.94 2 8
Average= 3.92
(KJ/cycle)

Cycle 154 GMT 13/ 3/2023 7:32: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.24 34 15.06 454 232 0.23 / 603.09 2 2
2 3 1031.04 1 15.20 1750 27 0.26 / 603.12 2 2
3 7 2004.56 33 14.93 2869 1414 1.67 / 604.53 2 2
4 13 1695.16 18 14.90 2530 679 2.35 / 605.21 2 3
5 13 1170.96 18 14.92 1894 509 2.86 / 605.72 2 3
6 13 494.96 18 15.02 1003 271 3.13 / 605.99 2 2
7 13 87.92 18 15.09 436 118 3.25 / 606.11 2 2
8 8 0.20 165 15.08 306 761 4.01 / 606.87 2 7
Average= 3.92
(KJ/cycle)

Cycle 153 GMT 3/ 3/2023 9:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 34 15.06 470 241 0.24 / 599.05 2 2
2 10 1000.08 2 15.12 1701 51 0.29 / 599.10 2 2
3 3 960.92 -1 15.43 8 0 0.05 / 599.10 2 2
4 7 2010.16 33 14.94 2878 1419 1.71 / 600.52 2 2
5 13 1682.32 18 14.92 2512 675 2.39 / 601.20 2 3
6 13 1163.40 18 14.93 1883 506 2.89 / 601.70 2 2
7 13 492.20 18 15.04 1006 272 3.16 / 601.98 2 3
8 13 77.36 18 15.12 425 116 3.28 / 602.09 2 2
9 8 0.16 165 15.10 309 770 4.05 / 602.86 2 7
Average= 3.91
(KJ/cycle)

Cycle 152 GMT 21/ 2/2023 12: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.20 34 15.06 481 246 0.25 / 595.02 2 2
2 10 1006.24 2 15.10 1727 52 0.30 / 595.08 2 2
3 3 970.20 -1 15.42 8 0 0.05 / 595.08 2 2
4 7 2004.52 33 14.93 2894 1426 1.72 / 596.50 2 2
5 13 1532.12 18 14.93 2339 629 2.35 / 597.13 2 3
6 13 1047.92 18 14.94 1749 470 2.82 / 597.60 2 3
7 13 547.76 18 15.02 1091 295 3.12 / 597.89 2 3
8 13 86.00 18 15.12 455 124 3.24 / 598.02 2 3
9 8 0.00 165 15.10 318 792 4.03 / 598.81 2 10
Average= 3.91
(KJ/cycle)

Cycle 151 GMT 11/ 2/2023 14:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.32 34 15.06 479 245 0.25 / 591.01 2 2
2 7 2003.80 33 14.94 2901 1430 1.68 / 592.44 2 2
3 13 1519.76 18 14.94 2336 628 2.30 / 593.07 2 2
4 13 1045.20 18 14.95 1752 471 2.78 / 593.54 2 3
5 13 542.88 18 15.02 1094 296 3.07 / 593.83 2 3
6 13 79.56 18 15.12 457 124 3.20 / 593.96 2 3
7 8 0.08 165 15.10 329 820 4.02 / 594.78 2 12
Average= 3.91
(KJ/cycle)

Cycle 150 GMT 1/ 2/2023 16:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 34 15.05 472 242 0.24 / 586.84 2 2
2 7 2004.48 33 14.93 2889 1423 1.66 / 588.26 2 2
3 13 1525.88 18 14.93 2350 632 2.30 / 588.89 2 2
4 13 1042.64 18 14.95 1746 470 2.77 / 589.36 2 3
5 13 537.28 18 15.02 1095 296 3.06 / 589.66 2 3
6 13 43.68 18 15.12 413 112 3.17 / 589.77 2 3
7 8 -0.08 165 15.09 338 842 4.02 / 590.61 2 12
8 14 -0.08 30 15.07 332 150 4.17 / 590.76 2 10
Average= 3.91
(KJ/cycle)

Cycle 149 GMT 22/ 1/2023 18:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.68 34 15.05 470 240 0.24 / 582.81 2 2
2 7 2013.72 33 14.93 2907 1432 1.67 / 584.24 2 2
3 13 1537.40 18 14.93 2358 634 2.31 / 584.88 2 3
4 13 1036.48 18 14.95 1753 472 2.78 / 585.35 2 3
5 13 537.40 18 15.02 1101 298 3.08 / 585.65 2 3
6 13 39.80 18 15.13 404 110 3.19 / 585.76 2 3
7 8 0.16 165 15.09 337 839 4.02 / 586.60 2 10
Average= 3.91
(KJ/cycle)

Cycle 148 GMT 12/ 1/2023 20:27: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.20 33 15.04 491 244 0.24 / 578.73 2 2
2 7 2013.24 34 14.93 2907 1476 1.72 / 580.21 2 2
3 13 1536.24 18 14.93 2364 635 2.35 / 580.84 2 3
4 13 1034.24 18 14.95 1746 470 2.82 / 581.31 2 3
5 13 528.88 18 15.02 1092 295 3.12 / 581.61 2 3
6 13 39.40 18 15.12 411 112 3.23 / 581.72 2 3
7 8 -0.04 165 15.09 342 852 4.08 / 582.57 2 10
Average= 3.91
(KJ/cycle)

Cycle 147 GMT 2/ 1/2023 22:37: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 33 15.05 493 245 0.24 / 574.67 2 2
2 7 2011.88 33 14.93 2907 1432 1.68 / 576.10 2 2
3 13 1535.28 18 14.93 2362 635 2.31 / 576.74 2 3
4 13 1047.80 18 14.95 1758 473 2.78 / 577.21 2 3
5 13 546.32 18 15.01 1118 302 3.09 / 577.51 2 3
6 13 33.36 18 15.12 406 110 3.20 / 577.62 2 3
7 8 0.24 165 15.09 347 864 4.06 / 578.49 2 12
Average= 3.91
(KJ/cycle)

Cycle 146 GMT 24/12/2022 0:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.08 33 15.04 475 236 0.24 / 570.62 2 2
2 7 2010.28 33 14.93 2907 1432 1.67 / 572.05 2 2
3 13 1524.64 18 14.93 2344 630 2.30 / 572.68 2 3
4 13 1037.96 18 14.94 1755 472 2.77 / 573.16 2 3
5 13 531.24 18 15.02 1100 297 3.07 / 573.45 2 3
6 13 33.24 18 15.12 405 110 3.18 / 573.56 2 3
7 8 -0.16 165 15.09 346 861 4.04 / 574.43 2 8
Average= 3.91
(KJ/cycle)

Cycle 145 GMT 14/12/2022 2:48: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 34 15.04 488 250 0.25 / 566.57 2 2
2 7 2013.92 34 14.93 2904 1474 1.72 / 568.04 2 2
3 13 1527.92 18 14.93 2339 629 2.35 / 568.67 2 3
4 13 900.64 18 14.97 1586 427 2.78 / 569.10 2 3
5 13 561.48 18 15.00 1142 308 3.09 / 569.41 2 3
6 13 36.48 18 15.12 415 113 3.20 / 569.52 2 3
7 8 0.12 165 15.08 349 868 4.07 / 570.39 2 11
Average= 3.91
(KJ/cycle)

Cycle 144 GMT 4/12/2022 4:48:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.72 34 15.07 457 234 0.23 / 562.46 2 2
2 10 1018.04 2 15.12 1750 53 0.29 / 562.52 2 2
3 3 967.64 -1 15.42 8 0 0.05 / 562.52 2 2
4 7 2005.88 33 14.93 2889 1423 1.71 / 563.94 2 2
5 13 1544.16 18 14.93 2365 636 2.35 / 564.58 2 3
6 13 1046.64 18 14.94 1768 475 2.82 / 565.05 2 3
7 13 545.48 18 15.01 1109 300 3.12 / 565.35 2 3
8 13 19.84 18 15.12 385 105 3.23 / 565.46 2 3
9 8 0.16 165 15.09 346 861 4.09 / 566.32 2 16
Average= 3.91
(KJ/cycle)

Cycle 143 GMT 24/11/2022 6:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.88 34 15.06 488 250 0.25 / 558.64 2 2
2 7 2005.44 33 14.94 2894 1427 1.68 / 560.07 2 2
3 13 1526.28 18 14.94 2346 631 2.31 / 560.70 2 2
4 13 1039.36 18 14.95 1737 467 2.77 / 561.17 2 3
5 13 400.88 18 15.06 894 242 3.02 / 561.41 2 3
6 8 -0.20 165 15.11 329 820 3.84 / 562.23 2 6
Average= 3.90
(KJ/cycle)

Cycle 142 GMT 14/11/2022 8:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 34 15.05 485 248 0.25 / 554.75 2 2
2 7 2008.16 33 14.93 2895 1426 1.67 / 556.18 2 2
3 13 1511.36 18 14.93 2324 625 2.30 / 556.80 2 3
4 13 1017.76 18 14.95 1719 463 2.76 / 557.26 2 3
5 13 507.92 18 15.03 1056 286 3.05 / 557.55 2 3
6 8 0.16 165 15.10 339 845 3.89 / 558.39 2 10
Average= 3.90
(KJ/cycle)

Cycle 141 GMT 4/11/2022 11: 2: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.44 34 15.04 471 241 0.24 / 550.83 2 2
2 7 2009.24 33 14.93 2893 1425 1.67 / 552.25 2 2
3 13 1532.80 18 14.93 2355 633 2.30 / 552.89 2 2
4 13 1050.96 18 14.94 1756 472 2.77 / 553.36 2 3
5 13 539.96 18 15.02 1096 296 3.07 / 553.66 2 3
6 8 0.24 165 15.10 339 845 3.91 / 554.50 2 11
Average= 3.90
(KJ/cycle)

Cycle 140 GMT 25/10/2022 13: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.24 34 15.06 470 241 0.24 / 546.85 2 2
2 7 2011.24 33 14.93 2891 1424 1.67 / 548.28 2 3
3 13 1523.04 18 14.92 2338 628 2.29 / 548.90 2 2
4 13 1039.68 18 14.93 1744 469 2.76 / 549.37 2 3
5 13 525.28 18 15.02 1070 289 3.05 / 549.66 2 3
6 13 31.36 18 15.12 384 105 3.16 / 549.77 2 3
7 8 -0.16 165 15.09 330 822 3.98 / 550.59 2 11
Average= 3.90
(KJ/cycle)

Cycle 139 GMT 15/10/2022 15:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.08 34 15.05 469 240 0.24 / 542.86 2 2
2 7 2010.32 33 14.95 2890 1426 1.67 / 544.29 2 2
3 13 1550.12 18 14.93 2358 634 2.30 / 544.92 2 3
4 13 1208.68 18 14.93 1941 522 2.82 / 545.44 2 3
5 13 513.96 18 15.04 1035 280 3.10 / 545.72 2 3
6 13 32.92 18 15.13 370 101 3.20 / 545.82 2 2
7 8 0.04 165 15.10 316 787 3.99 / 546.61 2 8
Average= 3.90
(KJ/cycle)

Cycle 138 GMT 5/10/2022 17:26: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.60 34 15.06 472 242 0.24 / 538.88 2 2
2 7 2002.84 33 14.94 2882 1421 1.66 / 540.30 2 2
3 13 1532.32 18 14.94 2340 629 2.29 / 540.93 2 2
4 13 1055.76 18 14.95 1754 472 2.76 / 541.41 2 3
5 13 545.20 18 15.02 1094 296 3.06 / 541.70 2 3
6 13 18.44 18 15.13 359 98 3.16 / 541.80 2 3
7 8 0.12 165 15.10 330 822 3.98 / 542.62 2 10
Average= 3.90
(KJ/cycle)

Cycle 137 GMT 25/ 9/2022 19:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.24 35 15.05 475 250 0.25 / 534.85 2 2
2 7 2002.44 33 14.95 2880 1421 1.67 / 536.27 2 2
3 13 1667.20 18 14.93 2507 674 2.34 / 536.94 2 2
4 13 1154.64 18 14.94 1884 507 2.85 / 537.45 2 3
5 13 472.84 18 15.05 996 270 3.12 / 537.72 2 3
6 13 30.40 18 15.14 382 104 3.23 / 537.83 2 2
7 8 -0.16 165 15.10 328 817 4.04 / 538.64 2 11
Average= 3.90
(KJ/cycle)

Cycle 136 GMT 15/ 9/2022 21:47: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.52 35 15.07 463 244 0.24 / 530.77 2 2
2 7 2004.28 33 14.93 2891 1424 1.67 / 532.20 2 3
3 13 1679.80 18 14.92 2520 677 2.35 / 532.88 2 2
4 13 1030.08 18 14.95 1730 466 2.81 / 533.34 2 3
5 13 529.36 18 15.02 1078 291 3.10 / 533.63 2 3
6 8 0.08 165 15.10 329 820 3.92 / 534.45 2 9
7 14 0.08 30 15.08 325 147 4.07 / 534.60 2 9
Average= 3.90
(KJ/cycle)

Cycle 135 GMT 5/ 9/2022 23:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 35 15.03 478 251 0.25 / 526.88 2 2
2 7 2003.92 34 14.94 2874 1460 1.71 / 528.34 2 2
3 13 1531.44 18 14.93 2332 627 2.34 / 528.96 2 3
4 13 1057.40 18 14.94 1753 471 2.81 / 529.44 2 3
5 13 543.76 18 15.03 1082 293 3.10 / 529.73 2 3
6 8 0.12 165 15.11 322 803 3.90 / 530.53 2 9
Average= 3.90
(KJ/cycle)

Cycle 134 GMT 27/ 8/2022 2: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.76 35 15.05 465 245 0.24 / 522.83 2 2
2 7 2005.64 33 14.94 2886 1423 1.67 / 524.25 2 3
3 13 1671.00 18 14.92 2519 677 2.34 / 524.93 2 2
4 13 1153.04 18 14.93 1875 504 2.85 / 525.43 2 3
5 13 478.96 18 15.03 999 270 3.12 / 525.70 2 3
6 13 56.16 18 15.11 414 113 3.23 / 525.82 2 3
7 8 0.00 165 15.08 325 809 4.04 / 526.63 2 12
Average= 3.90
(KJ/cycle)

Cycle 133 GMT 17/ 8/2022 4:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.72 35 15.06 458 241 0.24 / 518.90 2 2
2 7 2003.84 33 14.94 2878 1419 1.66 / 520.32 2 3
3 13 1520.04 18 14.94 2318 623 2.28 / 520.94 2 3
4 13 1040.44 18 14.96 1728 465 2.75 / 521.41 2 3
5 13 532.68 18 15.03 1061 287 3.04 / 521.69 2 3
6 13 17.96 18 15.13 354 96 3.13 / 521.79 2 2
7 8 -0.08 165 15.10 320 797 3.93 / 522.59 2 10
Average= 3.90
(KJ/cycle)

Cycle 132 GMT 7/ 8/2022 6:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 35 15.04 475 250 0.25 / 514.99 2 2
2 7 2005.04 33 14.94 2881 1420 1.67 / 516.41 2 2
3 13 1669.96 18 14.93 2503 673 2.34 / 517.09 2 2
4 13 1154.48 18 14.93 1882 506 2.85 / 517.59 2 3
5 13 471.20 18 15.05 982 266 3.11 / 517.86 2 3
6 8 0.20 165 15.11 320 798 3.91 / 518.66 2 8
Average= 3.90
(KJ/cycle)

Cycle 131 GMT 28/ 7/2022 8:33: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.76 35 15.05 475 250 0.25 / 511.06 2 2
2 7 2003.40 33 14.93 2880 1419 1.67 / 512.47 2 3
3 13 1526.36 18 14.93 2326 625 2.29 / 513.10 2 3
4 13 1044.44 18 14.94 1742 468 2.76 / 513.57 2 3
5 13 543.48 18 15.02 1078 291 3.05 / 513.86 2 3
6 13 17.76 18 15.13 348 95 3.15 / 513.95 2 2
7 8 0.12 165 15.09 317 789 3.94 / 514.74 2 8
Average= 3.90
(KJ/cycle)

Cycle 130 GMT 18/ 7/2022 10:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.56 35 15.04 460 242 0.24 / 507.16 2 2
2 7 2002.80 34 14.94 2867 1456 1.70 / 508.62 2 3
3 13 1528.76 18 14.93 2333 627 2.33 / 509.25 2 2
4 13 1187.48 18 14.92 1911 513 2.84 / 509.76 2 3
5 13 497.60 18 15.02 1009 273 3.11 / 510.03 2 3
6 8 0.16 165 15.09 310 772 3.88 / 510.81 2 5
Average= 3.90
(KJ/cycle)

Cycle 129 GMT 8/ 7/2022 13: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 35 15.04 471 248 0.25 / 503.15 2 2
2 7 2008.20 33 14.94 2883 1421 1.67 / 504.57 2 3
3 13 1533.56 18 14.93 2329 626 2.30 / 505.20 2 3
4 13 1202.24 18 14.93 1931 519 2.81 / 505.72 2 3
5 13 673.76 18 14.99 1240 335 3.15 / 506.05 2 3
6 13 29.56 18 15.11 360 98 3.25 / 506.15 2 2
7 8 0.00 165 15.08 310 771 4.02 / 506.92 2 9
Average= 3.90
(KJ/cycle)

Cycle 128 GMT 28/ 6/2022 15:18: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 35 15.06 455 240 0.24 / 499.15 2 2
2 7 2011.24 33 14.94 2877 1418 1.66 / 500.57 2 2
3 13 1684.72 18 14.92 2515 675 2.33 / 501.24 2 3
4 13 1162.88 18 14.94 1881 506 2.84 / 501.75 2 3
5 13 491.28 18 15.03 1002 271 3.11 / 502.02 2 3
6 13 65.16 18 15.11 409 111 3.22 / 502.13 2 2
7 8 0.08 165 15.09 311 774 4.00 / 502.90 2 9
Average= 3.90
(KJ/cycle)

Cycle 127 GMT 18/ 6/2022 17:33:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.60 35 15.05 464 244 0.24 / 495.28 2 2
2 7 2002.56 33 14.95 2873 1417 1.66 / 496.70 2 2
3 13 1546.52 18 14.93 2355 633 2.29 / 497.33 2 3
4 13 1080.28 18 14.95 1781 479 2.77 / 497.81 2 3
5 13 424.68 18 15.05 898 243 3.02 / 498.05 2 2
6 13 26.52 18 15.13 349 95 3.11 / 498.15 2 2
7 8 -0.04 165 15.10 306 762 3.87 / 498.91 2 8
Average= 3.90
(KJ/cycle)

Cycle 126 GMT 8/ 6/2022 19:35: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.16 35 15.05 452 238 0.24 / 491.25 2 2
2 7 2007.28 33 14.95 2875 1418 1.66 / 492.66 2 2
3 13 1546.52 18 14.93 2346 630 2.29 / 493.29 2 3
4 13 1215.64 18 14.93 1950 524 2.81 / 493.82 2 2
5 13 690.96 18 14.99 1257 339 3.15 / 494.16 2 3
6 13 68.76 18 15.11 408 111 3.26 / 494.27 2 2
7 8 0.36 165 15.09 307 764 4.03 / 495.03 2 9
Average= 3.90
(KJ/cycle)

Cycle 125 GMT 29/ 5/2022 21:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.32 35 15.05 456 240 0.24 / 487.15 2 2
2 7 2005.04 33 14.95 2874 1418 1.66 / 488.56 2 2
3 13 1670.92 18 14.93 2493 670 2.33 / 489.23 2 3
4 13 1152.04 18 14.94 1859 500 2.83 / 489.73 2 2
5 13 469.08 18 15.05 964 261 3.09 / 490.00 2 2
6 13 69.24 18 15.12 409 111 3.20 / 490.11 2 2
7 8 -0.08 165 15.10 306 762 3.96 / 490.87 2 5
8 14 -0.08 30 15.08 306 138 4.10 / 491.01 2 7
Average= 3.90
(KJ/cycle)

Cycle 124 GMT 20/ 5/2022 0:15: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.48 34 15.06 465 238 0.24 / 483.00 2 2
2 3 1022.28 1 15.21 1738 26 0.26 / 483.03 2 2
3 7 2014.56 33 14.95 2880 1421 1.69 / 484.45 2 2
4 13 1553.84 18 14.94 2371 638 2.32 / 485.09 2 2
5 13 1218.84 18 14.93 1956 526 2.85 / 485.61 2 2
6 13 516.72 18 15.04 1029 279 3.13 / 485.89 2 3
7 13 77.24 18 15.12 420 114 3.24 / 486.01 2 2
8 8 0.04 165 15.10 306 762 4.00 / 486.77 2 8
9 14 0.04 30 15.07 304 137 4.14 / 486.91 2 7
Average= 3.90
(KJ/cycle)

Cycle 123 GMT 10/ 5/2022 2:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.72 34 15.09 461 237 0.24 / 479.01 2 2
2 3 1028.80 1 15.22 1771 27 0.26 / 479.04 2 2
3 7 2006.84 33 14.96 2875 1419 1.68 / 480.46 2 3
4 13 1674.00 18 14.94 2503 673 2.36 / 481.13 2 2
5 13 1032.20 18 14.97 1716 462 2.82 / 481.60 2 3
6 13 548.12 18 15.04 1068 289 3.11 / 481.89 2 3
7 13 89.24 18 15.12 441 120 3.23 / 482.01 2 2
8 8 0.16 165 15.10 305 760 3.99 / 482.77 2 7
Average= 3.89
(KJ/cycle)

Cycle 122 GMT 30/ 4/2022 4:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 34 15.07 475 243 0.24 / 475.02 2 2
2 7 2005.04 33 14.97 2883 1424 1.67 / 476.44 2 3
3 13 1679.80 18 14.94 2513 676 2.34 / 477.12 2 2
4 13 1151.80 18 14.96 1866 502 2.85 / 477.62 2 3
5 13 484.72 18 15.07 993 269 3.12 / 477.89 2 3
6 13 66.40 18 15.15 411 112 3.23 / 478.00 2 2
7 8 -0.24 165 15.13 310 774 4.00 / 478.78 2 6
Average= 3.89
(KJ/cycle)

Cycle 121 GMT 20/ 4/2022 6:45: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.00 33 15.08 471 234 0.23 / 471.04 2 2
2 7 2003.76 33 14.96 2873 1418 1.65 / 472.46 2 3
3 13 1528.64 18 14.95 2348 632 2.28 / 473.09 2 3
4 13 1049.00 18 14.97 1759 474 2.76 / 473.56 2 3
5 13 541.92 18 15.04 1092 296 3.05 / 473.86 2 3
6 13 40.72 18 15.15 394 107 3.16 / 473.97 2 2
7 8 0.04 165 15.12 325 811 3.97 / 474.78 2 8
Average= 3.89
(KJ/cycle)

Cycle 120 GMT 10/ 4/2022 8:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.84 34 15.07 462 237 0.24 / 466.99 2 2
2 3 973.12 -1 15.43 8 0 0.00 / 466.99 2 2
3 7 2009.12 33 14.96 2881 1422 1.66 / 468.41 2 3
4 13 1680.28 18 14.93 2511 675 2.33 / 469.08 2 3
5 13 1148.84 18 14.96 1885 508 2.84 / 469.59 2 3
6 13 506.20 18 15.05 1051 285 3.13 / 469.87 2 3
7 13 77.92 18 15.14 444 121 3.25 / 470.00 2 2
8 8 0.24 165 15.12 324 808 4.06 / 470.80 2 8
Average= 3.89
(KJ/cycle)

Cycle 119 GMT 31/ 3/2022 11: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.40 34 15.07 464 238 0.24 / 462.86 2 2
2 7 2007.56 33 14.94 2887 1423 1.66 / 464.29 2 2
3 13 1528.44 18 14.94 2337 628 2.29 / 464.91 2 3
4 13 1034.20 18 14.96 1740 469 2.76 / 465.38 2 3
5 13 527.36 18 15.03 1076 291 3.05 / 465.67 2 3
6 13 66.60 18 15.13 433 118 3.17 / 465.79 2 3
7 8 -0.12 165 15.11 325 810 3.98 / 466.60 2 8
8 14 -0.12 30 15.08 323 146 4.12 / 466.75 2 10
Average= 3.89
(KJ/cycle)

Cycle 118 GMT 21/ 3/2022 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.44 34 15.07 467 239 0.24 / 458.91 2 2
2 7 2003.60 33 14.96 2875 1419 1.66 / 460.33 2 3
3 13 1541.64 18 14.94 2347 631 2.29 / 460.96 2 3
4 13 1061.12 18 14.96 1760 474 2.76 / 461.44 2 3
5 13 549.92 18 15.04 1082 293 3.06 / 461.73 2 3
6 13 82.80 18 15.14 439 120 3.18 / 461.85 2 2
7 8 0.16 165 15.12 311 776 3.95 / 462.63 2 9
Average= 3.89
(KJ/cycle)

Cycle 117 GMT 11/ 3/2022 15:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.12 34 15.08 463 237 0.24 / 454.96 2 2
2 7 2008.72 33 14.96 2890 1427 1.66 / 456.38 2 2
3 13 1535.72 18 14.94 2338 629 2.29 / 457.01 2 2
4 13 1053.36 18 14.96 1761 474 2.77 / 457.49 2 3
5 13 549.52 18 15.04 1088 295 3.06 / 457.78 2 3
6 13 42.60 18 15.15 385 105 3.17 / 457.89 2 2
7 8 0.12 165 15.11 316 788 3.95 / 458.67 2 9
Average= 3.89
(KJ/cycle)

Cycle 116 GMT 1/ 3/2022 17:14: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.72 34 15.08 479 246 0.25 / 450.95 2 2
2 7 2004.12 33 14.96 2883 1423 1.67 / 452.37 2 2
3 13 1687.92 18 14.94 2515 676 2.35 / 453.04 2 3
4 13 1166.08 18 14.95 1883 507 2.85 / 453.55 2 3
5 13 477.88 18 15.06 995 270 3.12 / 453.82 2 3
6 13 65.48 18 15.14 418 114 3.24 / 453.94 2 2
7 8 0.04 165 15.12 314 783 4.02 / 454.72 2 9
Average= 3.89
(KJ/cycle)

Cycle 115 GMT 19/ 2/2022 19:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.72 34 15.08 455 233 0.23 / 446.92 2 2
2 7 2010.52 33 14.96 2895 1429 1.66 / 448.35 2 3
3 13 1691.80 18 14.94 2525 679 2.34 / 449.03 2 2
4 13 1165.20 18 14.95 1890 509 2.85 / 449.53 2 3
5 13 485.12 18 15.06 998 271 3.12 / 449.80 2 3
6 13 64.76 18 15.15 418 114 3.23 / 449.92 2 2
7 8 0.20 165 15.12 313 781 4.02 / 450.70 2 12
Average= 3.89
(KJ/cycle)

Cycle 114 GMT 9/ 2/2022 21:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.68 34 15.08 464 238 0.24 / 442.90 2 2
2 7 2011.52 33 14.96 2877 1420 1.66 / 444.32 2 3
3 13 1537.60 18 14.95 2332 628 2.29 / 444.95 2 3
4 13 1039.76 18 14.97 1727 465 2.75 / 445.41 2 3
5 13 387.08 18 15.08 869 236 2.99 / 445.65 2 2
6 13 47.96 18 15.15 394 107 3.09 / 445.76 2 2
7 8 -0.04 165 15.12 315 786 3.88 / 446.54 2 9
8 14 -0.04 30 15.10 313 142 4.02 / 446.68 4 8
Average= 3.88
(KJ/cycle)

Cycle 113 GMT 30/ 1/2022 23:44: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 34 15.07 463 237 0.24 / 438.91 2 2
2 7 2007.28 33 14.96 2872 1418 1.66 / 440.32 2 3
3 13 1534.60 18 14.96 2345 631 2.29 / 440.96 2 3
4 13 1201.84 18 14.94 1934 520 2.81 / 441.48 2 3
5 13 515.64 18 15.06 1041 282 3.09 / 441.76 2 3
6 13 68.60 18 15.14 427 116 3.21 / 441.87 2 2
7 8 0.08 165 15.12 316 788 3.99 / 442.66 2 7
Average= 3.88
(KJ/cycle)

Cycle 112 GMT 21/ 1/2022 1:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.04 34 15.07 482 247 0.25 / 434.93 2 2
2 7 2010.04 33 14.96 2896 1430 1.68 / 436.36 2 2
3 13 1679.68 18 14.94 2514 676 2.35 / 437.03 2 3
4 13 1004.60 18 14.98 1693 457 2.81 / 437.49 2 3
5 13 499.92 18 15.06 1029 279 3.09 / 437.77 2 3
6 13 32.92 18 15.15 376 103 3.19 / 437.87 2 2
7 8 0.08 165 15.12 319 796 3.99 / 438.67 2 9
Average= 3.88
(KJ/cycle)

Cycle 111 GMT 11/ 1/2022 4: 9: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.44 34 15.07 485 249 0.25 / 430.92 2 2
2 7 2004.96 33 14.96 2878 1421 1.67 / 432.34 2 3
3 13 1540.16 18 14.95 2341 630 2.30 / 432.97 2 2
4 13 1198.80 18 14.94 1936 521 2.82 / 433.49 2 3
5 13 494.76 18 15.06 1021 277 3.10 / 433.76 2 3
6 13 59.12 18 15.14 420 114 3.21 / 433.88 2 2
7 8 0.08 165 15.12 322 803 4.01 / 434.68 2 7
Average= 3.88
(KJ/cycle)

Cycle 110 GMT 1/ 1/2022 6:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 34 15.07 476 244 0.24 / 426.97 2 2
2 7 2003.04 33 14.96 2874 1419 1.66 / 428.39 2 2
3 13 1525.20 18 14.95 2330 627 2.29 / 429.02 2 3
4 13 1034.28 18 14.97 1719 463 2.75 / 429.48 2 3
5 13 523.04 18 15.05 1057 286 3.04 / 429.77 2 3
6 13 35.36 18 15.15 380 104 3.14 / 429.87 2 2
7 8 0.16 165 15.12 320 798 3.94 / 430.67 2 7
Average= 3.88
(KJ/cycle)

Cycle 109 GMT 22/12/2021 8:36: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.84 34 15.07 482 247 0.25 / 423.02 2 2
2 7 2003.44 33 14.95 2886 1424 1.67 / 424.44 2 2
3 13 1667.28 18 14.94 2498 672 2.34 / 425.11 2 2
4 13 998.24 18 14.98 1678 452 2.79 / 425.57 2 3
5 13 501.08 18 15.06 1018 276 3.07 / 425.84 2 3
6 13 28.00 18 15.15 362 99 3.17 / 425.94 2 2
7 8 0.04 165 15.11 315 785 3.96 / 426.73 2 9
Average= 3.88
(KJ/cycle)

Cycle 108 GMT 12/12/2021 10:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.32 34 15.06 467 239 0.24 / 419.01 2 2
2 7 2010.36 34 14.95 2888 1468 1.71 / 420.48 2 2
3 13 1531.64 18 14.95 2340 630 2.34 / 421.11 2 3
4 13 1040.68 18 14.97 1732 467 2.80 / 421.58 2 3
5 13 522.52 18 15.05 1049 284 3.09 / 421.86 2 3
6 13 30.52 18 15.14 367 100 3.19 / 421.96 2 2
7 8 0.04 165 15.11 325 810 4.00 / 422.77 2 6
Average= 3.88
(KJ/cycle)

Cycle 107 GMT 2/12/2021 13:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.12 34 15.06 469 240 0.24 / 415.03 2 2
2 7 2007.12 33 14.96 2876 1420 1.66 / 416.45 2 3
3 13 1547.48 18 14.95 2350 632 2.29 / 417.09 2 2
4 13 1215.80 18 14.93 1949 524 2.82 / 417.61 2 3
5 13 509.80 18 15.04 1029 279 3.09 / 417.89 2 3
6 13 31.44 18 15.13 364 99 3.19 / 417.99 2 2
7 8 0.12 165 15.10 315 785 3.98 / 418.77 2 9
Average= 3.88
(KJ/cycle)

Cycle 106 GMT 22/11/2021 15:18:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.76 34 15.05 473 242 0.24 / 411.05 2 2
2 7 2008.72 33 14.96 2878 1421 1.66 / 412.47 2 2
3 13 1681.88 18 14.94 2499 672 2.33 / 413.14 2 3
4 13 1165.12 18 14.95 1883 507 2.84 / 413.65 2 2
5 13 498.20 18 15.05 1003 272 3.11 / 413.92 2 2
6 13 67.04 18 15.13 404 110 3.22 / 414.03 2 2
7 8 0.16 165 15.10 308 767 3.99 / 414.79 2 7
Average= 3.88
(KJ/cycle)

Cycle 105 GMT 12/11/2021 17:30: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.24 34 15.06 472 242 0.24 / 407.03 2 2
2 7 2010.96 33 14.96 2885 1424 1.67 / 408.45 2 3
3 13 1689.16 18 14.94 2516 677 2.34 / 409.13 2 2
4 13 1170.60 18 14.95 1899 511 2.85 / 409.64 2 3
5 13 484.04 18 15.05 1000 271 3.12 / 409.91 2 2
6 13 15.20 18 15.14 348 95 3.22 / 410.00 2 2
7 8 0.08 165 15.10 321 800 4.02 / 410.80 2 5
Average= 3.88
(KJ/cycle)

Cycle 104 GMT 2/11/2021 19:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.48 34 15.07 469 240 0.24 / 403.17 2 2
2 7 2004.12 33 14.98 2860 1414 1.65 / 404.58 2 2
3 13 1537.24 18 14.96 2335 629 2.28 / 405.21 2 3
4 13 1201.40 18 14.95 1921 517 2.80 / 405.72 2 3
5 13 516.56 18 15.05 1023 277 3.08 / 406.00 2 3
6 8 0.12 165 15.11 314 783 3.86 / 406.78 2 6
Average= 3.87
(KJ/cycle)

Cycle 103 GMT 23/10/2021 22:10: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.08 34 15.06 470 241 0.24 / 399.26 2 2
2 7 2004.96 34 14.97 2868 1460 1.70 / 400.72 2 2
3 13 1532.48 18 14.96 2332 628 2.33 / 401.35 2 2
4 13 1197.72 18 14.95 1914 515 2.84 / 401.86 2 3
5 13 495.92 18 15.06 993 269 3.11 / 402.13 2 2
6 8 0.16 165 15.12 318 793 3.91 / 402.93 2 6
Average= 3.87
(KJ/cycle)

Cycle 102 GMT 14/10/2021 0:22: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.56 34 15.07 458 235 0.23 / 395.26 2 2
2 7 2007.96 33 14.97 2877 1421 1.66 / 396.68 2 2
3 13 1678.36 18 14.95 2507 675 2.33 / 397.36 2 2
4 13 1166.00 18 14.96 1884 507 2.84 / 397.87 2 3
5 13 478.40 18 15.06 975 264 3.10 / 398.13 2 3
6 13 62.56 18 15.14 403 110 3.21 / 398.24 2 2
7 8 0.04 165 15.12 312 778 3.99 / 399.02 2 10
Average= 3.87
(KJ/cycle)

Cycle 101 GMT 4/10/2021 2:29: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.48 34 15.07 477 244 0.24 / 391.34 2 2
2 7 2004.36 33 14.96 2874 1419 1.66 / 392.76 2 2
3 13 1533.12 18 14.96 2340 630 2.29 / 393.39 2 2
4 13 1051.56 18 14.97 1746 470 2.76 / 393.86 2 3
5 13 547.60 18 15.05 1075 291 3.06 / 394.15 2 3
6 13 38.40 18 15.14 371 101 3.16 / 394.25 2 2
7 8 -0.04 165 15.11 311 775 3.93 / 395.03 2 9
Average= 3.87
(KJ/cycle)

Cycle 100 GMT 24/ 9/2021 4:38:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.36 34 15.07 458 235 0.23 / 387.40 2 2
2 7 2007.20 33 14.97 2879 1422 1.66 / 388.83 2 2
3 13 1539.60 18 14.96 2348 632 2.29 / 389.46 2 3
4 13 1056.64 18 14.97 1744 470 2.76 / 389.93 2 3
5 13 541.56 18 15.05 1068 289 3.05 / 390.22 2 3
6 13 38.40 18 15.14 369 101 3.15 / 390.32 2 2
7 8 0.24 165 15.11 312 778 3.93 / 391.10 2 9
Average= 3.87
(KJ/cycle)

Cycle 99 GMT 14/ 9/2021 6:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.28 34 15.07 461 236 0.24 / 383.54 2 2
2 7 2008.08 34 14.96 2874 1462 1.70 / 385.00 2 2
3 13 1520.60 18 14.96 2320 625 2.32 / 385.63 2 2
4 13 1025.28 18 14.98 1706 460 2.78 / 386.09 2 2
5 13 347.44 18 15.09 805 219 3.00 / 386.30 2 2
6 13 45.32 18 15.15 376 103 3.10 / 386.41 2 2
7 8 0.04 165 15.12 306 763 3.87 / 387.17 2 9
Average= 3.87
(KJ/cycle)

Cycle 98 GMT 4/ 9/2021 8:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 34 15.10 462 237 0.24 / 379.63 2 2
2 7 2008.40 34 14.95 2875 1461 1.70 / 381.09 2 3
3 13 1532.44 18 14.95 2336 629 2.33 / 381.72 2 2
4 13 1050.84 18 14.97 1742 469 2.80 / 382.19 2 3
5 13 386.84 18 15.08 857 233 3.03 / 382.42 2 2
6 13 43.88 18 15.14 380 104 3.13 / 382.52 2 2
7 8 0.20 165 15.11 313 780 3.91 / 383.30 2 8
Average= 3.87
(KJ/cycle)

Cycle 97 GMT 25/ 8/2021 11: 3: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.52 34 15.08 463 237 0.24 / 376.13 2 2
2 7 1590.12 34 15.06 2395 1226 1.46 / 377.35 2 2
3 13 1459.32 18 15.04 2237 606 2.07 / 377.96 2 3
4 13 970.80 18 15.05 1641 445 2.51 / 378.40 2 3
5 13 321.64 18 15.13 773 211 2.72 / 378.61 2 2
6 8 0.12 165 15.15 310 775 3.50 / 379.39 2 7
Average= 3.87
(KJ/cycle)

Cycle 96 GMT 15/ 8/2021 11: 2: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.48 34 15.07 469 240 0.24 / 372.32 2 2
2 7 1778.20 33 15.02 2614 1296 1.54 / 373.62 2 3
3 13 1629.56 18 14.99 2450 661 2.20 / 374.28 2 2
4 13 1111.04 18 15.00 1826 493 2.69 / 374.77 2 3
5 13 424.84 18 15.10 909 247 2.94 / 375.02 2 2
6 13 24.76 18 15.16 353 96 3.03 / 375.12 2 2
7 8 0.16 165 15.13 310 774 3.81 / 375.89 2 9
Average= 3.88
(KJ/cycle)

Cycle 95 GMT 5/ 8/2021 10:49: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 34 15.08 467 239 0.24 / 368.41 2 2
2 7 2009.44 33 14.96 2878 1421 1.66 / 369.83 2 3
3 13 1516.40 18 14.97 2328 627 2.29 / 370.46 2 2
4 13 1032.36 18 14.98 1716 463 2.75 / 370.92 2 3
5 13 518.64 18 15.06 1035 281 3.03 / 371.20 2 3
6 13 66.48 18 15.14 411 112 3.14 / 371.31 2 2
7 8 0.00 165 15.11 310 773 3.92 / 372.08 2 7
Average= 3.88
(KJ/cycle)

Cycle 94 GMT 26/ 7/2021 12:57: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.24 34 15.08 457 234 0.23 / 364.57 2 2
2 7 2003.20 33 14.97 2864 1415 1.65 / 365.99 2 2
3 13 1528.32 18 14.97 2326 627 2.28 / 366.61 2 2
4 13 1030.88 18 14.98 1716 463 2.74 / 367.08 2 3
5 13 365.60 18 15.10 826 225 2.96 / 367.30 2 2
6 13 42.20 18 15.15 372 101 3.06 / 367.40 2 2
7 8 0.08 165 15.12 307 766 3.83 / 368.17 2 8
Average= 3.88
(KJ/cycle)

Cycle 93 GMT 16/ 7/2021 15: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.80 34 15.08 491 252 0.25 / 360.68 2 2
2 3 1016.76 1 15.23 1741 27 0.28 / 360.71 2 2
3 7 2012.16 33 14.98 2881 1424 1.70 / 362.13 2 2
4 13 1537.16 18 14.97 2339 630 2.33 / 362.76 2 3
5 13 1054.04 18 14.99 1746 471 2.80 / 363.23 2 3
6 13 399.24 18 15.09 869 236 3.04 / 363.47 2 3
7 13 56.12 18 15.15 390 106 3.15 / 363.57 2 2
8 8 0.12 165 15.12 306 763 3.91 / 364.34 2 6
Average= 3.88
(KJ/cycle)

Cycle 92 GMT 6/ 7/2021 17: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.24 34 15.09 458 235 0.23 / 356.69 2 2
2 7 2009.52 33 14.98 2873 1420 1.66 / 358.11 2 3
3 13 1550.12 18 14.97 2351 634 2.29 / 358.75 2 2
4 13 1071.48 18 14.98 1767 476 2.77 / 359.22 2 3
5 13 563.28 18 15.06 1095 297 3.06 / 359.52 2 3
6 13 93.04 18 15.14 449 122 3.18 / 359.64 2 2
7 8 0.28 165 15.12 314 783 3.97 / 360.43 2 8
Average= 3.88
(KJ/cycle)

Cycle 91 GMT 26/ 6/2021 19: 1: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.40 34 15.09 460 236 0.24 / 352.73 2 2
2 7 2004.68 33 14.98 2879 1423 1.66 / 354.15 2 3
3 13 1670.40 18 14.97 2506 675 2.33 / 354.82 2 3
4 13 1026.92 18 15.00 1709 461 2.80 / 355.29 2 3
5 13 533.16 18 15.07 1054 286 3.08 / 355.57 2 3
6 13 81.60 18 15.15 435 119 3.20 / 355.69 2 2
7 8 -0.04 165 15.13 308 769 3.97 / 356.46 2 7
Average= 3.87
(KJ/cycle)

Cycle 90 GMT 16/ 6/2021 21:13: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.64 34 15.09 454 233 0.23 / 348.75 2 2
2 7 2009.92 33 14.98 2887 1427 1.66 / 350.18 2 3
3 13 1689.68 18 14.96 2523 679 2.34 / 350.86 2 2
4 13 1020.96 18 15.00 1710 462 2.80 / 351.32 2 2
5 13 520.56 18 15.07 1043 283 3.08 / 351.60 2 3
6 13 72.88 18 15.15 419 114 3.20 / 351.71 2 2
7 8 -0.04 165 15.13 311 776 3.97 / 352.49 2 6
Average= 3.87
(KJ/cycle)

Cycle 89 GMT 6/ 6/2021 23:21: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.64 34 15.09 445 228 0.23 / 344.83 2 2
2 7 2004.64 34 14.98 2864 1459 1.69 / 346.29 2 3
3 13 1506.60 18 14.97 2307 622 2.31 / 346.91 2 3
4 13 1016.60 18 15.00 1694 457 2.77 / 347.37 2 3
5 13 499.40 18 15.08 1010 274 3.04 / 347.64 2 2
6 13 68.40 18 15.16 412 112 3.15 / 347.75 2 2
7 8 0.20 165 15.13 305 761 3.91 / 348.52 2 10
Average= 3.87
(KJ/cycle)

Cycle 88 GMT 28/ 5/2021 1:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.04 34 15.10 438 225 0.22 / 340.95 2 2
2 7 2008.40 33 14.98 2872 1420 1.64 / 342.37 2 3
3 13 1524.60 18 14.98 2324 627 2.27 / 342.99 2 2
4 13 1027.72 18 14.99 1719 464 2.74 / 343.46 2 3
5 13 498.52 18 15.07 1013 275 3.01 / 343.73 2 3
6 13 40.12 18 15.16 372 102 3.11 / 343.84 2 2
7 8 0.08 165 15.13 307 766 3.88 / 344.60 2 6
Average= 3.87
(KJ/cycle)

Cycle 87 GMT 18/ 5/2021 3:39: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.36 34 15.09 462 237 0.24 / 336.99 2 2
2 7 2006.84 33 14.99 2881 1425 1.66 / 338.41 2 3
3 13 1676.12 18 14.96 2504 674 2.34 / 339.09 2 2
4 13 1139.96 18 14.98 1853 500 2.84 / 339.59 2 3
5 13 454.08 18 15.09 948 257 3.09 / 339.84 2 3
6 13 79.96 18 15.16 433 118 3.21 / 339.96 2 2
7 8 0.08 165 15.14 305 762 3.97 / 340.72 2 7
Average= 3.87
(KJ/cycle)

Cycle 86 GMT 8/ 5/2021 5:41: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.56 34 15.10 449 231 0.23 / 333.05 2 2
2 7 2012.44 33 14.98 2887 1427 1.66 / 334.48 2 2
3 13 1549.84 18 14.98 2356 635 2.29 / 335.11 2 2
4 13 1052.00 18 14.99 1757 474 2.77 / 335.59 2 3
5 13 549.08 18 15.07 1079 293 3.06 / 335.88 2 3
6 13 85.00 18 15.15 434 118 3.18 / 336.00 2 2
7 8 0.04 165 15.13 302 754 3.93 / 336.75 2 5
Average= 3.87
(KJ/cycle)

Cycle 85 GMT 28/ 4/2021 7:42: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.84 34 15.09 447 229 0.23 / 329.06 2 2
2 7 2012.04 34 14.97 2890 1471 1.70 / 330.53 2 2
3 13 1664.28 18 14.97 2495 672 2.37 / 331.20 2 3
4 13 1136.56 18 14.98 1856 500 2.87 / 331.70 2 3
5 13 434.68 18 15.10 924 251 3.12 / 331.95 2 2
6 13 61.40 18 15.16 400 109 3.23 / 332.06 2 2
7 8 0.00 165 15.14 302 754 3.99 / 332.82 2 8
Average= 3.87
(KJ/cycle)

Cycle 84 GMT 18/ 4/2021 9:26: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.68 34 15.10 440 226 0.23 / 325.11 2 2
2 7 2004.32 33 14.99 2875 1422 1.65 / 326.53 2 2
3 13 1507.72 18 14.99 2297 620 2.27 / 327.15 2 3
4 13 1021.40 18 15.00 1694 457 2.73 / 327.61 2 3
5 13 511.32 18 15.08 1020 277 3.00 / 327.88 2 2
6 13 85.76 18 15.15 432 118 3.12 / 328.00 2 2
7 13 21.12 18 15.16 333 91 3.21 / 328.09 2 2
8 8 0.08 165 15.13 296 739 3.95 / 328.83 2 8
Average= 3.87
(KJ/cycle)

Cycle 83 GMT 8/ 4/2021 11:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.24 34 15.11 440 226 0.23 / 321.14 2 2
2 7 2004.24 33 15.01 2862 1418 1.64 / 322.56 2 2
3 13 1524.04 18 14.99 2315 625 2.27 / 323.18 2 3
4 13 1060.00 18 15.00 1738 469 2.74 / 323.65 2 3
5 13 548.20 18 15.08 1064 289 3.03 / 323.94 2 2
6 13 106.00 18 15.15 454 124 3.15 / 324.07 2 2
7 13 30.16 18 15.16 341 93 3.24 / 324.16 2 2
8 8 0.12 165 15.14 289 722 3.97 / 324.88 2 6
Average= 3.87
(KJ/cycle)

Cycle 82 GMT 29/ 3/2021 13:30: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 104.24 34 15.13 427 220 0.22 / 317.06 2 2
2 7 2010.60 34 14.99 2875 1465 1.68 / 318.53 2 3
3 13 1677.72 18 14.98 2505 675 2.36 / 319.20 2 2
4 13 1151.88 18 14.99 1868 504 2.86 / 319.71 2 3
5 13 468.68 18 15.10 963 262 3.13 / 319.97 2 2
6 13 89.84 18 15.17 430 117 3.24 / 320.09 2 2
7 13 49.04 18 15.17 370 101 3.34 / 320.19 2 2
8 8 0.00 165 15.15 291 727 4.07 / 320.92 2 7
Average= 3.87
(KJ/cycle)

Cycle 81 GMT 19/ 3/2021 15:40: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.80 34 15.11 434 223 0.22 / 313.14 2 2
2 7 1781.68 33 15.04 2625 1303 1.53 / 314.44 2 2
3 13 1630.60 18 15.02 2464 666 2.19 / 315.11 2 3
4 13 1281.28 18 15.01 2027 548 2.74 / 315.65 2 3
5 13 389.52 18 15.14 858 234 2.97 / 315.89 2 2
6 13 64.32 18 15.20 401 110 3.08 / 316.00 2 2
7 13 47.16 18 15.19 372 102 3.18 / 316.10 2 2
8 8 0.00 165 15.17 297 743 3.93 / 316.84 2 8
Average= 3.86
(KJ/cycle)

Cycle 80 GMT 9/ 3/2021 15:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.88 34 15.12 440 226 0.23 / 309.13 2 2
2 7 2004.48 33 14.99 2872 1421 1.65 / 310.55 2 2
3 13 1538.28 18 14.99 2340 631 2.28 / 311.18 2 3
4 13 1065.68 18 15.01 1761 476 2.75 / 311.66 2 3
5 13 555.16 18 15.08 1080 293 3.05 / 311.95 2 3
6 13 91.96 18 15.17 442 121 3.17 / 312.07 2 2
7 13 21.56 18 15.18 341 93 3.26 / 312.17 2 2
8 8 0.00 165 15.15 299 747 4.01 / 312.92 2 8
Average= 3.86
(KJ/cycle)

Cycle 79 GMT 27/ 2/2021 17:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.52 34 15.13 436 224 0.22 / 305.22 2 2
2 7 2009.40 33 15.00 2875 1423 1.65 / 306.64 2 2
3 13 1527.40 18 15.00 2328 629 2.28 / 307.27 2 2
4 13 1053.64 18 15.02 1735 469 2.75 / 307.74 2 3
5 13 400.56 18 15.12 870 237 2.98 / 307.98 2 2
6 13 64.16 18 15.18 399 109 3.09 / 308.09 2 2
7 13 19.60 18 15.19 333 91 3.18 / 308.18 2 2
8 8 0.12 165 15.16 292 730 3.91 / 308.91 2 9
Average= 3.86
(KJ/cycle)

Cycle 78 GMT 17/ 2/2021 19: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.88 34 15.13 447 230 0.23 / 301.19 2 2
2 7 2011.48 33 14.99 2873 1421 1.65 / 302.61 2 3
3 13 1685.44 18 14.98 2513 678 2.33 / 303.29 2 3
4 13 1149.04 18 15.00 1859 502 2.83 / 303.79 2 3
5 13 455.24 18 15.12 940 256 3.09 / 304.05 2 2
6 13 63.88 18 15.19 403 110 3.20 / 304.16 2 2
7 13 18.56 18 15.19 334 91 3.29 / 304.25 2 2
8 8 0.04 165 15.16 297 743 4.03 / 304.99 2 9
Average= 3.86
(KJ/cycle)

Cycle 77 GMT 7/ 2/2021 20:50: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.96 34 15.13 440 226 0.23 / 297.26 2 2
2 7 2002.84 33 15.00 2863 1417 1.64 / 298.68 2 2
3 13 1533.44 18 15.00 2336 631 2.27 / 299.31 2 2
4 13 1040.32 18 15.02 1727 467 2.74 / 299.78 2 3
5 13 388.20 18 15.14 854 233 2.97 / 300.01 2 2
6 13 97.60 18 15.19 446 122 3.10 / 300.13 2 2
7 13 23.76 18 15.19 341 93 3.19 / 300.22 2 2
8 8 0.12 165 15.17 295 738 3.93 / 300.96 2 9
Average= 3.86
(KJ/cycle)

Cycle 76 GMT 28/ 1/2021 22:44: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.76 34 15.14 452 233 0.23 / 293.10 2 2
2 3 1015.60 1 15.26 1736 26 0.26 / 293.13 2 2
3 7 2013.28 33 15.01 2894 1433 1.69 / 294.56 2 2
4 13 1698.56 18 14.98 2534 683 2.38 / 295.24 2 3
5 13 1158.00 18 15.00 1878 507 2.88 / 295.75 2 3
6 13 643.12 18 15.08 1199 325 3.21 / 296.08 2 3
7 13 63.32 18 15.19 404 110 3.32 / 296.19 2 2
8 13 35.68 18 15.19 360 98 3.42 / 296.29 2 2
9 8 0.08 165 15.16 300 750 4.17 / 297.04 2 9
Average= 3.86
(KJ/cycle)

Cycle 75 GMT 19/ 1/2021 0:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 120.28 34 15.14 457 235 0.24 / 289.17 2 2
2 7 2006.72 33 15.01 2880 1427 1.66 / 290.59 2 2
3 13 1503.76 18 15.01 2307 623 2.29 / 291.22 2 2
4 13 1164.76 18 15.01 1892 511 2.80 / 291.73 2 3
5 13 476.88 18 15.12 974 265 3.06 / 291.99 2 3
6 13 69.32 18 15.20 413 113 3.17 / 292.11 2 2
7 8 -0.04 165 15.17 304 761 3.94 / 292.87 2 8
Average= 3.85
(KJ/cycle)

Cycle 74 GMT 9/ 1/2021 3: 5: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 34 15.15 445 229 0.23 / 285.30 2 2
2 7 2012.44 33 15.01 2898 1435 1.66 / 286.73 2 2
3 13 1528.80 18 15.01 2334 631 2.30 / 287.36 2 3
4 13 1045.52 18 15.03 1736 470 2.76 / 287.83 2 2
5 13 400.24 18 15.14 873 238 3.00 / 288.07 2 2
6 13 61.84 18 15.20 398 109 3.11 / 288.18 2 2
7 8 0.08 165 15.18 300 751 3.86 / 288.93 2 10
Average= 3.85
(KJ/cycle)

Cycle 73 GMT 30/12/2020 5: 0: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.96 34 15.15 450 232 0.23 / 281.33 2 2
2 3 1016.68 1 15.27 1736 27 0.26 / 281.35 2 2
3 7 2008.88 33 15.01 2877 1425 1.68 / 282.78 2 3
4 13 1664.64 18 15.00 2498 674 2.36 / 283.45 2 2
5 13 1140.56 18 15.02 1850 500 2.86 / 283.95 2 3
6 13 458.80 18 15.13 952 259 3.12 / 284.21 2 3
7 13 42.84 18 15.21 373 102 3.22 / 284.32 2 2
8 8 0.20 165 15.18 301 754 3.97 / 285.07 2 8
Average= 3.85
(KJ/cycle)

Cycle 72 GMT 20/12/2020 7:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.24 34 15.15 451 232 0.23 / 277.45 2 2
2 7 2008.36 33 15.01 2880 1427 1.66 / 278.88 2 3
3 13 1536.16 18 15.01 2339 632 2.29 / 279.51 2 3
4 13 1048.20 18 15.03 1740 471 2.76 / 279.98 2 3
5 13 403.00 18 15.14 879 240 3.00 / 280.22 2 2
6 13 48.36 18 15.21 387 106 3.11 / 280.33 2 2
7 8 0.00 165 15.18 307 769 3.88 / 281.10 2 6
Average= 3.85
(KJ/cycle)

Cycle 71 GMT 10/12/2020 9:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.96 34 15.14 463 238 0.24 / 273.45 2 2
2 7 2011.08 33 15.02 2889 1432 1.67 / 274.88 2 2
3 13 1539.28 18 15.01 2343 633 2.30 / 275.52 2 3
4 13 1048.72 18 15.04 1733 469 2.77 / 275.98 2 2
5 13 390.08 18 15.16 859 234 3.01 / 276.22 2 2
6 13 27.76 18 15.22 354 97 3.10 / 276.32 2 2
7 8 0.16 165 15.19 306 767 3.87 / 277.08 2 8
8 14 0.16 30 15.17 303 138 4.01 / 277.22 2 14
Average= 3.85
(KJ/cycle)

Cycle 70 GMT 30/11/2020 11: 6: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.88 34 15.15 462 238 0.24 / 269.49 2 2
2 7 2003.68 34 15.01 2869 1464 1.70 / 270.95 2 2
3 13 1518.00 18 15.01 2327 629 2.33 / 271.58 2 3
4 13 1023.84 18 15.04 1706 462 2.79 / 272.04 2 3
5 13 500.80 18 15.13 1011 275 3.07 / 272.32 2 3
6 13 60.68 18 15.21 408 112 3.18 / 272.43 2 2
7 8 0.08 165 15.19 312 782 3.96 / 273.21 2 11
Average= 3.85
(KJ/cycle)

Cycle 69 GMT 20/11/2020 13:15:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.64 33 15.16 455 228 0.23 / 265.55 2 2
2 7 2010.80 33 15.02 2884 1429 1.66 / 266.98 2 3
3 13 1518.88 18 15.02 2316 626 2.28 / 267.61 2 2
4 13 1044.52 18 15.04 1739 471 2.75 / 268.08 2 3
5 13 537.00 18 15.12 1058 288 3.04 / 268.37 2 3
6 13 36.00 18 15.22 370 101 3.14 / 268.47 2 2
7 8 -0.04 165 15.19 311 779 3.92 / 269.25 2 10
Average= 3.85
(KJ/cycle)

Cycle 68 GMT 10/11/2020 15:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.84 33 15.16 461 231 0.23 / 261.59 2 2
2 7 2002.72 33 15.03 2871 1424 1.65 / 263.02 2 2
3 13 1524.44 18 15.03 2330 630 2.28 / 263.65 2 2
4 13 1185.44 18 15.02 1918 519 2.80 / 264.16 2 3
5 13 488.20 18 15.15 995 271 3.07 / 264.44 2 3
6 13 61.84 18 15.23 405 111 3.19 / 264.55 2 2
7 8 0.08 165 15.20 311 780 3.97 / 265.33 2 10
Average= 3.85
(KJ/cycle)

Cycle 67 GMT 31/10/2020 17:34: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.32 33 15.16 454 227 0.23 / 257.68 2 2
2 7 2004.08 33 15.02 2866 1421 1.65 / 259.10 2 3
3 13 1523.36 18 15.02 2319 627 2.27 / 259.72 2 2
4 13 1035.76 18 15.05 1724 467 2.74 / 260.19 2 3
5 13 519.20 18 15.14 1040 283 3.03 / 260.47 2 3
6 13 32.12 18 15.23 367 101 3.13 / 260.57 2 2
7 8 0.16 165 15.20 314 788 3.91 / 261.36 2 9
Average= 3.84
(KJ/cycle)

Cycle 66 GMT 21/10/2020 19:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.40 33 15.16 460 230 0.23 / 253.74 2 2
2 7 2011.16 33 15.02 2875 1425 1.66 / 255.16 2 3
3 13 1537.60 18 15.02 2334 631 2.29 / 255.79 2 3
4 13 1060.04 18 15.05 1744 472 2.76 / 256.27 2 3
5 13 531.84 18 15.14 1059 289 3.05 / 256.55 2 3
6 13 30.24 18 15.24 367 101 3.15 / 256.65 2 2
7 8 0.12 165 15.21 316 793 3.94 / 257.45 2 8
Average= 3.84
(KJ/cycle)

Cycle 65 GMT 11/10/2020 21:51: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 116.60 33 15.17 462 231 0.23 / 249.82 2 2
2 7 2008.88 33 15.03 2877 1427 1.66 / 251.24 2 2
3 13 1525.24 18 15.03 2322 628 2.29 / 251.87 2 3
4 13 1032.56 18 15.06 1723 467 2.75 / 252.34 2 3
5 13 515.92 18 15.15 1039 283 3.04 / 252.62 2 3
6 13 34.24 18 15.24 368 101 3.14 / 252.72 2 2
7 8 0.08 165 15.21 313 786 3.92 / 253.51 2 9
Average= 3.84
(KJ/cycle)

Cycle 64 GMT 1/10/2020 23:55: 2

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.40 33 15.18 455 228 0.23 / 245.88 2 2
2 7 2002.72 33 15.03 2868 1422 1.65 / 247.30 2 3
3 13 1670.08 18 15.02 2495 675 2.32 / 247.97 2 2
4 13 994.92 18 15.07 1674 454 2.78 / 248.43 2 3
5 13 505.76 18 15.16 1018 278 3.06 / 248.70 2 3
6 13 33.80 18 15.25 366 100 3.16 / 248.81 2 2
7 8 0.04 165 15.22 310 779 3.94 / 249.58 2 7
Average= 3.84
(KJ/cycle)

Cycle 63 GMT 22/ 9/2020 1:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.80 33 15.17 465 233 0.23 / 241.89 2 2
2 7 2007.36 33 15.03 2878 1427 1.66 / 243.32 2 3
3 13 1675.24 18 15.02 2500 676 2.34 / 244.00 2 3
4 13 1137.60 18 15.05 1849 501 2.84 / 244.50 2 3
5 13 458.92 18 15.17 960 262 3.10 / 244.76 2 3
6 13 29.68 18 15.25 364 100 3.20 / 244.86 2 2
7 8 0.08 165 15.22 314 789 3.99 / 245.65 2 8
Average= 3.84
(KJ/cycle)

Cycle 62 GMT 12/ 9/2020 4: 0: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.72 33 15.18 455 228 0.23 / 237.95 2 2
2 7 2009.92 33 15.04 2885 1432 1.66 / 239.38 2 3
3 13 1526.16 18 15.03 2327 630 2.29 / 240.01 2 3
4 13 1046.48 18 15.06 1734 470 2.76 / 240.48 2 3
5 13 523.60 18 15.16 1045 285 3.04 / 240.77 2 3
6 13 31.56 18 15.25 365 100 3.14 / 240.87 2 2
7 8 0.20 165 15.22 315 791 3.94 / 241.66 2 9
Average= 3.84
(KJ/cycle)

Cycle 61 GMT 2/ 9/2020 6: 6: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.76 33 15.19 464 233 0.23 / 234.01 2 2
2 7 2007.76 34 15.03 2878 1471 1.70 / 235.48 2 2
3 13 1518.36 18 15.04 2315 627 2.33 / 236.10 2 2
4 13 1010.48 18 15.07 1695 460 2.79 / 236.56 2 3
5 13 490.00 18 15.16 1007 275 3.06 / 236.84 2 2
6 13 28.28 18 15.25 362 99 3.16 / 236.94 2 2
7 8 -0.04 165 15.22 313 786 3.95 / 237.72 2 10
Average= 3.83
(KJ/cycle)

Cycle 60 GMT 23/ 8/2020 8: 4: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 33 15.19 459 230 0.23 / 230.16 2 2
2 7 2010.04 34 15.03 2883 1473 1.70 / 231.63 2 3
3 13 1508.24 18 15.04 2311 626 2.33 / 232.25 2 2
4 13 1002.32 18 15.08 1682 457 2.79 / 232.71 2 3
5 13 475.32 18 15.17 985 269 3.05 / 232.98 2 3
6 8 0.20 165 15.23 316 794 3.85 / 233.77 2 6
Average= 3.83
(KJ/cycle)

Cycle 59 GMT 13/ 8/2020 10:12: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.12 33 15.19 467 234 0.23 / 226.32 2 2
2 7 2004.92 33 15.04 2871 1425 1.66 / 227.75 2 3
3 13 1517.40 18 15.04 2317 627 2.29 / 228.37 2 3
4 13 1016.32 18 15.08 1703 462 2.75 / 228.83 2 3
5 13 353.36 18 15.21 813 223 2.97 / 229.06 2 2
6 13 38.68 18 15.26 370 102 3.07 / 229.16 2 2
7 8 -0.16 165 15.24 305 767 3.84 / 229.93 2 9
Average= 3.83
(KJ/cycle)

Cycle 58 GMT 3/ 8/2020 12: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.92 33 15.20 463 232 0.23 / 222.32 2 2
2 7 2009.60 33 15.05 2885 1433 1.67 / 223.75 2 2
3 13 1520.72 18 15.05 2328 631 2.30 / 224.39 2 3
4 13 1053.40 18 15.08 1747 474 2.77 / 224.86 2 3
5 13 546.60 18 15.16 1075 293 3.06 / 225.15 2 3
6 8 0.16 165 15.24 314 790 3.85 / 225.94 2 5
7 14 0.16 30 15.22 314 143 4.00 / 226.09 2 8
Average= 3.83
(KJ/cycle)

Cycle 57 GMT 24/ 7/2020 14:13: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.72 33 15.20 456 229 0.23 / 218.40 2 2
2 7 2009.64 33 15.05 2871 1426 1.65 / 219.83 2 2
3 13 1520.92 18 15.05 2327 630 2.28 / 220.46 2 2
4 13 1039.48 18 15.08 1733 470 2.76 / 220.93 2 3
5 13 526.72 18 15.17 1045 285 3.04 / 221.21 2 3
6 13 30.36 18 15.27 360 99 3.14 / 221.31 2 2
7 8 0.24 165 15.24 310 780 3.92 / 222.09 2 8
Average= 3.83
(KJ/cycle)

Cycle 56 GMT 14/ 7/2020 16:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.48 33 15.21 453 227 0.23 / 214.50 2 2
2 7 2005.60 33 15.05 2861 1421 1.65 / 215.92 2 2
3 13 1510.76 18 15.06 2309 626 2.27 / 216.55 2 3
4 13 1017.80 18 15.09 1702 462 2.74 / 217.01 2 3
5 13 501.04 18 15.18 1014 277 3.01 / 217.29 2 2
6 13 30.80 18 15.27 363 100 3.11 / 217.39 2 2
7 8 0.08 165 15.24 311 782 3.90 / 218.17 2 11
Average= 3.83
(KJ/cycle)

Cycle 55 GMT 4/ 7/2020 18:29: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.16 33 15.21 461 231 0.23 / 210.73 2 2
2 7 2009.84 34 15.05 2874 1471 1.70 / 212.20 2 2
3 13 1516.28 18 15.05 2307 625 2.33 / 212.82 2 2
4 13 1009.28 18 15.10 1690 459 2.79 / 213.28 2 3
5 13 346.60 18 15.22 800 219 3.01 / 213.50 2 2
6 8 0.12 165 15.25 307 772 3.78 / 214.28 2 6
Average= 3.83
(KJ/cycle)

Cycle 54 GMT 24/ 6/2020 20:31: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.72 33 15.21 449 225 0.23 / 206.85 2 2
2 7 2006.40 33 15.06 2870 1426 1.65 / 208.28 2 3
3 13 1533.40 18 15.06 2330 632 2.28 / 208.91 2 2
4 13 1050.92 18 15.09 1736 472 2.75 / 209.38 2 3
5 13 379.16 18 15.22 844 231 2.99 / 209.61 2 2
6 13 43.04 18 15.28 378 104 3.09 / 209.72 2 2
7 8 0.04 165 15.25 310 780 3.87 / 210.50 2 6
Average= 3.83
(KJ/cycle)

Cycle 53 GMT 14/ 6/2020 22:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 33 15.22 454 228 0.23 / 202.92 2 2
2 7 2005.52 33 15.07 2877 1431 1.66 / 204.35 2 2
3 13 1528.00 18 15.06 2333 632 2.29 / 204.99 2 3
4 13 1034.24 18 15.10 1723 468 2.76 / 205.45 2 3
5 13 516.20 18 15.19 1032 282 3.04 / 205.74 2 2
6 13 65.92 18 15.28 411 113 3.15 / 205.85 2 2
7 8 0.20 165 15.25 309 778 3.93 / 206.63 2 8
Average= 3.83
(KJ/cycle)

Cycle 52 GMT 5/ 6/2020 0:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.88 33 15.22 458 230 0.23 / 198.99 2 2
2 7 2012.24 33 15.06 2889 1436 1.67 / 200.42 2 2
3 13 1519.32 18 15.07 2319 629 2.29 / 201.05 2 2
4 13 1044.32 18 15.10 1734 471 2.77 / 201.52 2 3
5 13 522.64 18 15.19 1042 285 3.05 / 201.81 2 3
6 13 64.96 18 15.28 408 112 3.16 / 201.92 2 2
7 8 0.04 165 15.26 308 776 3.94 / 202.69 2 8
Average= 3.82
(KJ/cycle)

Cycle 51 GMT 26/ 5/2020 2:37:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.76 33 15.22 451 227 0.23 / 194.96 2 2
2 7 2002.64 33 15.07 2869 1427 1.65 / 196.39 2 2
3 13 1666.76 18 15.06 2494 676 2.33 / 197.06 2 3
4 13 1123.56 18 15.10 1830 497 2.83 / 197.56 2 3
5 13 597.36 18 15.18 1142 312 3.14 / 197.87 2 3
6 13 49.20 18 15.29 386 106 3.25 / 197.98 2 2
7 8 0.12 165 15.26 309 778 4.02 / 198.76 2 8
Average= 3.82
(KJ/cycle)

Cycle 50 GMT 16/ 5/2020 4:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.44 33 15.23 455 229 0.23 / 191.04 2 2
2 7 2005.12 33 15.07 2869 1427 1.66 / 192.47 2 2
3 13 1521.32 18 15.07 2322 630 2.29 / 193.10 2 3
4 13 1190.72 18 15.08 1919 521 2.81 / 193.62 2 3
5 13 344.88 18 15.24 801 220 3.03 / 193.84 2 2
6 13 78.24 18 15.28 430 118 3.14 / 193.96 2 2
7 8 0.00 165 15.26 307 773 3.92 / 194.73 2 7
Average= 3.82
(KJ/cycle)

Cycle 49 GMT 6/ 5/2020 6:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.68 33 15.22 442 222 0.22 / 187.09 2 2
2 7 2008.68 33 15.07 2876 1430 1.65 / 188.52 2 3
3 13 1521.72 18 15.07 2320 629 2.28 / 189.15 2 3
4 13 1174.64 18 15.09 1895 515 2.80 / 189.67 2 2
5 13 465.40 18 15.21 966 264 3.06 / 189.93 2 3
6 13 62.72 18 15.29 407 112 3.17 / 190.04 2 2
7 8 0.32 165 15.27 306 771 3.94 / 190.82 2 10
Average= 3.82
(KJ/cycle)

Cycle 48 GMT 26/ 4/2020 9: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.96 33 15.23 453 228 0.23 / 182.99 2 2
2 7 2010.88 33 15.08 2880 1433 1.66 / 184.43 2 3
3 13 1541.24 18 15.07 2334 633 2.29 / 185.06 2 3
4 13 1206.56 18 15.08 1920 521 2.82 / 185.58 2 3
5 13 491.60 18 15.21 994 272 3.09 / 185.85 2 2
6 13 61.00 18 15.29 404 111 3.20 / 185.97 2 2
7 8 -0.04 165 15.27 305 768 3.97 / 186.73 2 8
8 14 -0.04 30 15.25 302 138 4.11 / 186.87 2 7
Average= 3.81
(KJ/cycle)

Cycle 47 GMT 16/ 4/2020 11:16: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 114.92 33 15.24 453 228 0.23 / 179.08 2 2
2 7 2005.72 33 15.09 2865 1427 1.65 / 180.50 2 3
3 13 1498.48 18 15.09 2286 621 2.28 / 181.12 2 3
4 13 1160.80 18 15.10 1869 508 2.78 / 181.63 2 2
5 13 465.96 18 15.22 955 262 3.05 / 181.89 2 3
6 13 59.72 18 15.30 397 109 3.15 / 182.00 2 2
7 8 0.12 165 15.27 303 763 3.92 / 182.77 2 7
Average= 3.81
(KJ/cycle)

Cycle 46 GMT 6/ 4/2020 13:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.96 33 15.24 440 221 0.22 / 175.22 2 2
2 7 2007.56 33 15.09 2871 1430 1.65 / 176.65 2 2
3 13 1519.08 18 15.09 2311 628 2.28 / 177.28 2 2
4 13 1043.20 18 15.12 1726 470 2.75 / 177.75 2 2
5 13 384.76 18 15.25 850 233 2.98 / 177.98 2 2
6 13 55.60 18 15.30 390 107 3.09 / 178.09 2 2
7 8 0.04 165 15.28 302 761 3.85 / 178.85 2 6
Average= 3.81
(KJ/cycle)

Cycle 45 GMT 27/ 3/2020 15:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.44 33 15.25 443 223 0.22 / 171.36 2 2
2 7 2005.20 33 15.09 2858 1423 1.65 / 172.79 2 3
3 13 1529.96 18 15.09 2329 633 2.28 / 173.42 2 3
4 13 1054.28 18 15.13 1742 474 2.75 / 173.89 2 3
5 13 390.96 18 15.25 856 235 2.99 / 174.13 2 2
6 13 57.52 18 15.31 392 108 3.10 / 174.24 2 2
7 8 0.20 165 15.29 302 762 3.86 / 175.00 2 8
Average= 3.80
(KJ/cycle)

Cycle 44 GMT 17/ 3/2020 17:22: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.48 33 15.25 452 227 0.23 / 167.44 2 2
2 7 2005.64 34 15.08 2868 1470 1.70 / 168.91 2 3
3 13 1510.76 18 15.09 2312 628 2.33 / 169.54 2 2
4 13 1019.28 18 15.13 1698 462 2.79 / 170.00 2 3
5 13 497.80 18 15.23 1004 275 3.06 / 170.28 2 3
6 13 37.24 18 15.31 366 101 3.16 / 170.38 2 2
7 8 -0.16 165 15.29 303 764 3.93 / 171.14 2 7
Average= 3.80
(KJ/cycle)

Cycle 43 GMT 7/ 3/2020 19:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 118.16 33 15.25 453 228 0.23 / 163.41 2 2
2 7 2003.24 34 15.08 2871 1472 1.70 / 164.88 2 3
3 13 1499.96 18 15.10 2289 622 2.32 / 165.50 2 2
4 13 1023.68 18 15.14 1713 467 2.79 / 165.97 2 3
5 13 343.12 18 15.27 800 220 3.01 / 166.19 2 2
6 13 76.16 18 15.31 425 117 3.13 / 166.30 2 2
7 8 0.16 165 15.29 305 769 3.90 / 167.07 2 5
8 14 0.16 30 15.27 302 138 4.03 / 167.21 2 7
Average= 3.80
(KJ/cycle)

Cycle 42 GMT 26/ 2/2020 21:18: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.68 33 15.25 446 224 0.22 / 159.52 2 2
2 7 2005.76 34 15.08 2879 1476 1.70 / 161.00 2 2
3 13 1504.52 18 15.10 2293 623 2.32 / 161.62 2 3
4 13 1004.60 18 15.14 1694 462 2.79 / 162.08 2 3
5 13 325.80 18 15.27 777 214 3.00 / 162.30 2 2
6 13 33.92 18 15.32 370 102 3.10 / 162.40 2 2
7 8 0.04 165 15.29 309 780 3.88 / 163.18 2 8
Average= 3.79
(KJ/cycle)

Cycle 41 GMT 16/ 2/2020 23:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.56 33 15.25 448 225 0.23 / 155.64 2 2
2 7 2005.28 33 15.09 2874 1431 1.66 / 157.07 2 3
3 13 1518.32 18 15.10 2322 631 2.29 / 157.70 2 3
4 13 1037.56 18 15.13 1735 473 2.76 / 158.18 2 3
5 13 378.52 18 15.26 851 234 2.99 / 158.41 2 3
6 13 40.12 18 15.32 380 105 3.10 / 158.51 2 2
7 8 0.16 165 15.30 310 783 3.88 / 159.30 2 9
Average= 3.79
(KJ/cycle)

Cycle 40 GMT 7/ 2/2020 1: 8: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.56 33 15.26 450 227 0.23 / 151.75 2 2
2 7 2005.08 33 15.09 2880 1434 1.66 / 153.18 2 2
3 13 1542.00 18 15.09 2345 637 2.30 / 153.82 2 3
4 13 1037.04 18 15.14 1725 470 2.77 / 154.29 2 3
5 13 383.60 18 15.26 857 235 3.00 / 154.53 2 3
6 13 42.68 18 15.32 380 105 3.11 / 154.63 2 2
7 8 0.12 165 15.29 311 785 3.89 / 155.42 2 7
Average= 3.79
(KJ/cycle)

Cycle 39 GMT 28/ 1/2020 3: 2: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.08 33 15.26 451 227 0.23 / 147.82 2 2
2 7 2003.28 33 15.09 2879 1434 1.66 / 149.25 2 3
3 13 1518.40 18 15.10 2321 631 2.29 / 149.88 2 3
4 13 1019.64 18 15.14 1705 465 2.76 / 150.35 2 3
5 13 508.76 18 15.24 1023 281 3.04 / 150.63 2 3
6 13 58.00 18 15.32 403 111 3.15 / 150.74 2 2
7 8 0.00 165 15.30 311 785 3.93 / 151.52 2 5
Average= 3.79
(KJ/cycle)

Cycle 38 GMT 18/ 1/2020 4:58: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.72 33 15.26 457 230 0.23 / 143.84 2 2
2 7 2010.00 33 15.09 2874 1431 1.66 / 145.27 2 3
3 13 1679.28 18 15.09 2499 679 2.34 / 145.94 2 3
4 13 1152.00 18 15.13 1857 506 2.85 / 146.45 2 3
5 13 457.28 18 15.25 949 261 3.11 / 146.71 2 2
6 13 27.44 18 15.34 358 99 3.21 / 146.81 2 2
7 8 -0.12 165 15.30 309 780 3.99 / 147.59 2 8
Average= 3.78
(KJ/cycle)

Cycle 37 GMT 8/ 1/2020 7: 7: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.84 33 15.27 454 229 0.23 / 139.93 2 2
2 3 1015.68 1 15.37 1739 27 0.26 / 139.96 2 2
3 7 2003.52 33 15.10 2868 1429 1.68 / 141.39 2 3
4 13 1520.84 18 15.11 2311 629 2.31 / 142.01 2 2
5 13 1038.16 18 15.15 1717 468 2.78 / 142.48 2 3
6 13 384.24 18 15.27 847 233 3.01 / 142.72 2 2
7 13 41.84 18 15.33 376 104 3.12 / 142.82 2 2
8 8 0.00 165 15.31 311 786 3.90 / 143.60 2 8
Average= 3.78
(KJ/cycle)

Cycle 36 GMT 29/12/2019 8:59: 3

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.92 33 15.27 456 230 0.23 / 136.06 2 2
2 7 2005.32 33 15.11 2867 1430 1.66 / 137.49 2 3
3 13 1521.92 18 15.11 2318 630 2.29 / 138.12 2 2
4 13 1046.48 18 15.15 1731 472 2.76 / 138.59 2 3
5 13 377.48 18 15.28 837 230 2.99 / 138.82 2 2
6 13 44.56 18 15.34 376 104 3.10 / 138.93 2 2
7 8 0.00 165 15.31 306 773 3.87 / 139.70 2 10
Average= 3.78
(KJ/cycle)

Cycle 35 GMT 19/12/2019 10:52:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 102.52 33 15.28 443 223 0.22 / 132.17 2 2
2 7 2006.84 34 15.10 2873 1475 1.70 / 133.65 2 3
3 13 1515.32 18 15.11 2305 627 2.33 / 134.27 2 3
4 13 1030.56 18 15.16 1707 466 2.79 / 134.74 2 3
5 13 363.48 18 15.29 816 225 3.02 / 134.96 2 2
6 13 17.44 18 15.35 340 94 3.11 / 135.06 2 2
7 8 0.12 165 15.31 307 776 3.89 / 135.83 2 9
Average= 3.77
(KJ/cycle)

Cycle 34 GMT 9/12/2019 12:53: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.20 33 15.27 453 228 0.23 / 128.33 2 2
2 7 2004.88 33 15.11 2874 1433 1.66 / 129.76 2 2
3 13 1527.00 18 15.12 2321 632 2.29 / 130.39 2 3
4 13 1025.88 18 15.17 1703 465 2.76 / 130.86 2 3
5 13 373.68 18 15.29 831 229 2.99 / 131.09 2 2
6 13 19.68 18 15.35 337 93 3.08 / 131.18 2 2
7 8 -0.08 165 15.32 304 768 3.85 / 131.95 2 7
Average= 3.77
(KJ/cycle)

Cycle 33 GMT 29/11/2019 14:53: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.96 33 15.28 456 230 0.23 / 124.34 2 2
2 7 2010.56 33 15.11 2877 1435 1.66 / 125.77 2 2
3 13 1520.12 18 15.12 2317 631 2.30 / 126.40 2 3
4 13 1036.20 18 15.17 1717 469 2.76 / 126.87 2 3
5 13 364.40 18 15.29 816 225 2.99 / 127.09 2 2
6 13 18.28 18 15.35 337 93 3.08 / 127.19 2 2
7 8 0.16 165 15.32 305 771 3.85 / 127.96 2 10
8 14 0.16 30 15.30 305 140 3.99 / 128.10 2 8
Average= 3.77
(KJ/cycle)

Cycle 32 GMT 19/11/2019 16:50: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 105.84 33 15.29 467 236 0.24 / 120.52 2 2
2 7 2003.76 33 15.12 2867 1431 1.67 / 121.95 2 2
3 13 1512.80 18 15.13 2308 629 2.29 / 122.58 2 3
4 13 1025.84 18 15.17 1706 466 2.76 / 123.05 2 3
5 13 502.08 18 15.27 1007 277 3.04 / 123.32 2 2
6 8 0.12 165 15.33 309 782 3.82 / 124.11 2 5
Average= 3.76
(KJ/cycle)

Cycle 31 GMT 9/11/2019 18:56: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 101.12 32 15.29 449 220 0.22 / 116.72 2 2
2 7 2003.60 34 15.12 2865 1473 1.69 / 118.19 2 3
3 13 1500.08 18 15.14 2289 624 2.32 / 118.82 2 3
4 13 1020.08 18 15.18 1702 465 2.78 / 119.28 2 3
5 13 330.68 18 15.31 778 214 3.00 / 119.50 2 2
6 8 0.04 165 15.33 313 792 3.79 / 120.29 2 6
Average= 3.76
(KJ/cycle)

Cycle 30 GMT 30/10/2019 21: 3: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 103.16 32 15.29 453 222 0.22 / 112.88 2 2
2 7 2006.60 33 15.12 2872 1433 1.65 / 114.31 2 2
3 13 1533.16 18 15.13 2326 633 2.29 / 114.95 2 3
4 13 1058.52 18 15.17 1743 476 2.76 / 115.42 2 3
5 13 540.00 18 15.26 1061 291 3.06 / 115.72 2 3
6 8 0.12 165 15.33 310 784 3.84 / 116.50 2 7
Average= 3.76
(KJ/cycle)

Cycle 29 GMT 20/10/2019 22:47:59

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.12 32 15.30 454 222 0.22 / 109.06 2 2
2 7 2008.12 33 15.13 2876 1436 1.66 / 110.50 2 2
3 13 1509.88 18 15.14 2299 627 2.28 / 111.12 2 3
4 13 1024.48 18 15.19 1707 467 2.75 / 111.59 2 3
5 13 512.44 18 15.27 1024 281 3.03 / 111.87 2 3
6 8 0.16 165 15.34 312 790 3.82 / 112.66 2 5
Average= 3.76
(KJ/cycle)

Cycle 28 GMT 11/10/2019 0:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 32 15.29 467 228 0.23 / 105.16 2 2
2 7 2009.96 33 15.13 2886 1441 1.67 / 106.60 2 2
3 13 1509.88 18 15.14 2306 628 2.30 / 107.23 2 3
4 13 1014.20 18 15.19 1693 463 2.76 / 107.69 2 3
5 13 327.72 18 15.32 777 214 2.98 / 107.91 2 2
6 8 0.04 165 15.34 311 787 3.76 / 108.70 2 7
7 14 0.04 30 15.32 310 142 3.90 / 108.84 3 9
Average= 3.75
(KJ/cycle)

Cycle 27 GMT 1/10/2019 3: 5: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.32 32 15.31 462 226 0.23 / 101.27 2 2
2 7 2003.56 34 15.12 2867 1474 1.70 / 102.74 2 2
3 13 1505.36 18 15.14 2300 627 2.33 / 103.37 2 3
4 13 1171.40 18 15.16 1890 516 2.84 / 103.88 2 3
5 13 453.24 18 15.29 948 261 3.10 / 104.14 2 2
6 8 -0.04 165 15.34 312 790 3.89 / 104.93 2 9
Average= 3.75
(KJ/cycle)

Cycle 26 GMT 21/ 9/2019 5:17: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 32 15.31 463 227 0.23 / 97.36 2 2
2 3 1016.12 1 15.40 1745 27 0.25 / 97.39 2 2
3 7 2002.88 33 15.14 2871 1434 1.69 / 98.82 2 3
4 13 1671.60 18 15.13 2501 681 2.37 / 99.50 2 3
5 13 1132.04 18 15.17 1848 505 2.87 / 100.01 2 3
6 13 429.60 18 15.30 910 251 3.12 / 100.26 2 2
7 8 0.24 165 15.35 309 783 3.91 / 101.04 2 6
Average= 3.74
(KJ/cycle)

Cycle 25 GMT 11/ 9/2019 7:26:58

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 106.72 32 15.30 452 221 0.22 / 93.59 2 2
2 7 2004.20 33 15.14 2866 1432 1.65 / 95.02 2 3
3 13 1513.72 18 15.15 2309 630 2.28 / 95.65 2 3
4 13 1031.12 18 15.19 1713 468 2.75 / 96.12 2 3
5 13 352.08 18 15.32 806 222 2.97 / 96.34 2 2
6 8 0.12 165 15.35 311 788 3.76 / 97.13 2 7
Average= 3.74
(KJ/cycle)

Cycle 24 GMT 1/ 9/2019 9:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.60 32 15.31 459 225 0.22 / 89.65 2 2
2 7 2004.40 34 15.14 2869 1477 1.70 / 91.13 2 2
3 13 1673.04 18 15.14 2504 682 2.38 / 91.81 2 2
4 13 998.96 18 15.21 1669 457 2.84 / 92.27 2 3
5 13 345.56 18 15.32 793 219 3.06 / 92.49 2 2
6 13 16.60 18 15.38 341 94 3.15 / 92.58 2 2
7 8 -0.08 165 15.35 311 788 3.94 / 93.37 2 10
Average= 3.73
(KJ/cycle)

Cycle 23 GMT 22/ 8/2019 11:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.64 32 15.32 455 223 0.22 / 85.86 2 2
2 7 2005.24 33 15.14 2869 1433 1.66 / 87.29 2 3
3 13 1669.64 18 15.13 2496 680 2.34 / 87.97 2 2
4 13 1005.00 18 15.21 1680 460 2.80 / 88.43 2 3
5 13 343.52 18 15.33 791 218 3.01 / 88.65 2 2
6 8 0.16 165 15.36 308 781 3.80 / 89.43 2 4
Average= 3.73
(KJ/cycle)

Cycle 22 GMT 12/ 8/2019 13:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.44 32 15.31 452 221 0.22 / 81.98 2 2
2 3 1017.20 1 15.39 1744 27 0.25 / 82.01 2 2
3 7 2003.64 33 15.15 2867 1433 1.68 / 83.44 2 3
4 13 1521.16 18 15.16 2310 630 2.31 / 84.07 2 3
5 13 1180.28 18 15.17 1904 520 2.83 / 84.59 2 2
6 13 463.16 18 15.30 953 262 3.09 / 84.85 2 2
7 8 0.12 165 15.36 309 783 3.88 / 85.63 2 6
Average= 3.72
(KJ/cycle)

Cycle 21 GMT 2/ 8/2019 15:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.08 32 15.32 455 223 0.22 / 78.07 2 2
2 7 2005.00 33 15.15 2885 1442 1.67 / 79.51 2 3
3 13 1509.72 18 15.17 2311 631 2.30 / 80.14 2 2
4 13 1014.80 18 15.21 1692 463 2.76 / 80.60 2 3
5 13 502.32 18 15.30 1007 277 3.04 / 80.88 2 3
6 13 30.44 18 15.38 356 99 3.14 / 80.98 2 2
7 8 0.08 165 15.35 307 778 3.91 / 81.76 2 6
Average= 3.72
(KJ/cycle)

Cycle 20 GMT 23/ 7/2019 17:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.60 32 15.32 457 224 0.22 / 74.21 2 2
2 7 2002.60 33 15.14 2884 1441 1.66 / 75.65 2 3
3 13 1514.76 18 15.16 2322 634 2.30 / 76.29 2 3
4 13 999.64 18 15.21 1678 459 2.76 / 76.75 2 3
5 13 308.00 18 15.34 747 206 2.96 / 76.95 2 2
6 13 56.88 18 15.38 396 110 3.07 / 77.06 2 2
7 8 0.20 165 15.36 308 781 3.85 / 77.84 2 6
Average= 3.71
(KJ/cycle)

Cycle 19 GMT 13/ 7/2019 19:19: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.96 32 15.31 466 228 0.23 / 70.35 2 2
2 7 2006.72 33 15.15 2878 1439 1.67 / 71.79 2 3
3 13 1514.72 18 15.17 2310 631 2.30 / 72.42 2 2
4 13 1016.32 18 15.21 1701 466 2.76 / 72.89 2 4
5 13 361.20 18 15.33 819 226 2.99 / 73.11 2 2
6 13 42.96 18 15.38 373 103 3.09 / 73.22 2 2
7 8 0.08 165 15.36 305 773 3.87 / 73.99 2 7
Average= 3.70
(KJ/cycle)

Cycle 18 GMT 3/ 7/2019 21:14: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.32 32 15.32 463 227 0.23 / 66.41 2 2
2 7 2014.24 33 15.15 2892 1446 1.67 / 67.85 2 3
3 13 1530.16 18 15.17 2337 638 2.31 / 68.49 2 2
4 13 1029.52 18 15.21 1717 470 2.78 / 68.96 2 4
5 13 500.28 18 15.30 1012 279 3.06 / 69.24 2 3
6 13 30.48 18 15.39 360 100 3.16 / 69.34 2 2
7 8 -0.08 165 15.36 310 786 3.95 / 70.12 2 11
Average= 3.69
(KJ/cycle)

Cycle 17 GMT 23/ 6/2019 22:59: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 111.28 32 15.32 458 225 0.22 / 62.55 2 2
2 7 2002.36 33 15.15 2872 1436 1.66 / 63.98 2 3
3 13 1504.88 18 15.17 2295 627 2.29 / 64.61 2 3
4 13 1014.60 18 15.22 1697 465 2.75 / 65.07 2 3
5 13 342.12 18 15.34 794 219 2.97 / 65.29 2 2
6 13 31.64 18 15.39 364 101 3.07 / 65.39 2 2
7 8 0.08 165 15.36 310 786 3.86 / 66.18 2 7
Average= 3.68
(KJ/cycle)

Cycle 16 GMT 14/ 6/2019 0:55: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.00 32 15.33 453 222 0.22 / 58.69 2 2
2 7 2004.68 33 15.15 2882 1441 1.66 / 60.13 2 3
3 13 1501.92 18 15.18 2298 628 2.29 / 60.75 2 3
4 13 990.88 18 15.22 1665 456 2.75 / 61.21 2 3
5 13 309.28 18 15.35 756 209 2.96 / 61.42 2 2
6 13 55.32 18 15.39 399 111 3.07 / 61.53 2 2
7 8 0.00 165 15.36 312 791 3.86 / 62.32 2 7
Average= 3.67
(KJ/cycle)

Cycle 15 GMT 4/ 6/2019 2:46: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 108.88 32 15.33 453 222 0.22 / 54.81 2 2
2 7 2006.00 33 15.15 2896 1448 1.67 / 56.26 2 2
3 13 1514.16 18 15.18 2314 632 2.30 / 56.89 2 3
4 13 1019.08 18 15.21 1709 468 2.77 / 57.36 2 4
5 13 347.32 18 15.34 806 223 2.99 / 57.58 2 2
6 13 46.36 18 15.39 383 106 3.10 / 57.68 2 2
7 8 0.08 165 15.37 307 779 3.88 / 58.46 2 7
Average= 3.65
(KJ/cycle)

Cycle 14 GMT 25/ 5/2019 4:34: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.12 32 15.33 459 225 0.23 / 50.96 2 2
2 7 2003.96 33 15.16 2880 1441 1.67 / 52.40 2 3
3 13 1495.72 18 15.18 2290 626 2.29 / 53.03 2 3
4 13 997.88 18 15.23 1684 462 2.75 / 53.49 2 4
5 13 316.32 18 15.35 764 211 2.96 / 53.70 2 2
6 13 36.68 18 15.40 371 103 3.07 / 53.80 2 2
7 8 0.16 165 15.37 309 784 3.85 / 54.59 2 8
Average= 3.64
(KJ/cycle)

Cycle 13 GMT 15/ 5/2019 6:34: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.24 32 15.34 454 223 0.22 / 47.06 2 2
2 7 2005.44 34 15.15 2883 1485 1.71 / 48.54 2 3
3 13 1506.68 18 15.18 2310 631 2.34 / 49.18 2 3
4 13 992.92 18 15.23 1669 458 2.80 / 49.63 2 4
5 13 307.64 18 15.35 756 209 3.01 / 49.84 2 2
6 13 32.84 18 15.40 367 102 3.11 / 49.94 2 2
7 8 0.04 165 15.37 312 791 3.90 / 50.74 2 8
Average= 3.62
(KJ/cycle)

Cycle 12 GMT 5/ 5/2019 8:26: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 115.52 32 15.34 461 226 0.23 / 43.10 2 2
2 7 2006.60 33 15.16 2874 1438 1.66 / 44.54 2 2
3 13 1505.84 18 15.19 2310 632 2.30 / 45.17 2 3
4 13 1151.96 18 15.20 1871 512 2.81 / 45.68 2 3
5 13 434.48 18 15.33 929 256 3.06 / 45.94 2 3
6 13 51.12 18 15.40 396 110 3.17 / 46.05 2 2
7 8 0.04 165 15.37 311 789 3.96 / 46.84 2 8
Average= 3.60
(KJ/cycle)

Cycle 11 GMT 25/ 4/2019 10:28: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.08 31 15.34 438 208 0.21 / 39.20 2 2
2 7 2002.60 34 15.16 2879 1484 1.69 / 40.68 2 3
3 13 1497.72 18 15.19 2297 628 2.32 / 41.31 2 3
4 13 991.60 18 15.23 1668 457 2.78 / 41.76 2 5
5 13 295.40 18 15.36 742 205 2.98 / 41.97 2 2
6 13 50.96 18 15.40 398 110 3.09 / 42.08 2 2
7 8 0.20 165 15.37 313 794 3.89 / 42.87 2 6
Average= 3.57
(KJ/cycle)

Cycle 10 GMT 15/ 4/2019 12:12: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 119.28 31 15.34 457 217 0.22 / 35.34 2 2
2 7 2004.88 33 15.16 2892 1447 1.66 / 36.79 2 3
3 13 1495.88 18 15.19 2297 628 2.29 / 37.42 2 4
4 13 994.00 18 15.23 1679 460 2.75 / 37.88 2 3
5 13 329.92 18 15.35 784 217 2.97 / 38.09 2 3
6 13 38.28 18 15.40 376 104 3.07 / 38.20 2 2
7 8 -0.04 165 15.38 311 789 3.86 / 38.99 2 7
Average= 3.54
(KJ/cycle)

Cycle 9 GMT 5/ 4/2019 13:51: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 109.92 31 15.35 452 215 0.22 / 31.58 2 2
2 7 2002.00 30 15.19 2888 1316 1.53 / 32.89 2 3
3 13 1517.40 18 15.19 2322 635 2.17 / 33.53 2 3
4 13 1029.68 18 15.23 1725 473 2.64 / 34.00 2 4
5 13 366.44 18 15.35 835 231 2.87 / 34.23 2 2
6 13 46.32 18 15.41 388 108 2.98 / 34.34 2 2
7 8 0.20 165 15.38 309 784 3.76 / 35.12 2 8
Average= 3.51
(KJ/cycle)

Cycle 8 GMT 26/ 3/2019 15:24: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 117.32 31 15.35 457 217 0.22 / 27.69 2 2
2 7 2002.52 30 15.20 2893 1319 1.54 / 29.01 2 3
3 13 1671.72 18 15.18 2497 682 2.22 / 29.70 2 3
4 13 1141.44 18 15.22 1856 508 2.73 / 30.20 2 3
5 13 467.00 18 15.33 968 267 2.99 / 30.47 2 3
6 13 53.56 18 15.41 397 110 3.10 / 30.58 2 2
7 8 0.00 165 15.38 308 782 3.89 / 31.36 2 8
Average= 3.48
(KJ/cycle)

Cycle 7 GMT 16/ 3/2019 17:11: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.04 31 15.35 454 216 0.22 / 23.82 2 2
2 3 1022.96 1 15.42 1747 27 0.24 / 23.85 2 3
3 7 2004.40 30 15.21 2870 1310 1.55 / 25.16 2 2
4 13 1546.16 18 15.20 2347 642 2.19 / 25.80 2 3
5 13 1207.00 18 15.21 1932 529 2.72 / 26.33 2 3
6 13 492.88 18 15.34 995 275 3.00 / 26.60 2 3
7 13 37.96 18 15.42 368 102 3.10 / 26.71 2 2
8 8 -0.04 165 15.39 304 772 3.87 / 27.48 2 9
Average= 3.43
(KJ/cycle)

Cycle 6 GMT 6/ 3/2019 18:58: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 112.64 30 15.36 449 207 0.21 / 19.96 2 2
2 3 1022.08 1 15.42 1747 27 0.23 / 19.99 2 3
3 7 2002.24 38 15.16 2851 1642 1.88 / 21.63 2 3
4 13 1320.68 18 15.22 2054 563 2.44 / 22.20 2 3
5 13 821.48 18 15.28 1428 393 2.83 / 22.59 2 3
6 13 146.80 18 15.40 521 144 2.98 / 22.73 2 2
7 13 24.92 18 15.42 350 97 3.07 / 22.83 2 2
8 8 0.08 165 15.39 305 775 3.85 / 23.60 2 8
Average= 3.37
(KJ/cycle)

Cycle 5 GMT 24/ 2/2019 20:36: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 100.68 31 15.37 434 207 0.21 / 16.18 2 2
2 7 2005.32 38 15.16 2847 1640 1.85 / 17.82 2 2
3 13 1301.96 18 15.23 2030 557 2.40 / 18.38 2 3
4 13 794.60 18 15.29 1388 382 2.79 / 18.76 2 3
5 13 126.52 18 15.42 490 136 2.92 / 18.89 2 2
6 13 31.28 18 15.42 353 98 3.02 / 18.99 2 2
7 8 0.04 165 15.40 301 765 3.78 / 19.76 2 11
Average= 3.29
(KJ/cycle)

Cycle 4 GMT 14/ 2/2019 22:23: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.28 30 15.37 449 207 0.21 / 12.47 2 2
2 7 1508.48 74 15.19 2225 2501 2.71 / 14.98 2 3
3 13 131.48 18 15.42 499 139 2.85 / 15.11 2 2
4 13 23.00 18 15.44 343 95 2.94 / 15.21 2 2
5 8 0.12 165 15.41 300 763 3.70 / 15.97 2 9
Average= 3.19
(KJ/cycle)

Cycle 3 GMT 13/ 2/2019 22:41: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 113.44 30 15.36 451 208 0.21 / 8.68 2 2
2 3 1023.44 1 15.43 1728 27 0.23 / 8.70 2 2
3 7 1520.80 74 15.19 2241 2519 2.75 / 11.22 2 3
4 13 262.96 18 15.40 674 187 2.94 / 11.41 2 2
5 13 22.44 18 15.43 342 95 3.04 / 11.50 2 2
6 8 0.04 165 15.40 301 765 3.80 / 12.27 2 9
Average= 3.07
(KJ/cycle)

Cycle 2 GMT 12/ 2/2019 23: 7: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 107.48 29 15.39 434 194 0.19 / 4.93 2 2
2 3 1025.20 1 15.43 1752 27 0.22 / 4.96 2 2
3 7 1517.76 74 15.19 2231 2508 2.73 / 7.47 2 3
4 13 126.88 18 15.42 489 136 2.86 / 7.61 2 2
5 13 29.80 18 15.43 351 97 2.96 / 7.70 2 2
6 8 0.04 165 15.40 301 765 3.73 / 8.47 2 7
Average= 2.82
(KJ/cycle)

Cycle 1 GMT 11/ 2/2019 23:25: 0

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 110.04 29 15.57 409 185 0.18 / 1.82 2 3
2 3 1043.76 1 15.44 1764 27 0.21 / 1.84 2 3
3 7 979.96 74 15.33 1565 1775 1.99 / 3.62 2 3
4 8 0.00 240 15.44 303 1123 3.11 / 4.74 2 13
Average= 2.37
(KJ/cycle)

Cycle 0 GMT 11/ 2/2019 12:51: 1

Number Code Pressure
(db)
Pump
Time (s)
Voltage
(V)
Current
(ma)
Energy
(J)
Cumulative
Energy (KJ)
Vacuum0
(load-start)
Vacuum1
(load-stop)
1 2 124.56 28 15.69 430 189 0.19 / 0.19 2 3
2 7 138.28 74 15.67 435 504 0.69 / 0.69 2 2
3 8 0.04 240 15.63 250 938 1.63 / 1.63 2 7
Average= 1.63
(KJ/cycle)